Sie sind auf Seite 1von 16

THE LEADING FORCE behind liquids since 1857

3600 Series Heavy Duty Pumps


General Purpose Pumps for Mixing, Blending, Recirculating, Fixed and Mobile Transfer

THE UNSTOPPABLE

ROPERS
The early history of the Roper Company is truly a triumph of American grit over adversity.
George D. Roper, was challenged from childhood by the loss of his left arm in a train accident. He chopped wood and performed other duties as well as other boys with two good hands, asking no consideration because of having only one arm. In 1889 at age 34, George D. Roper founded the Roper legacy with the purchase of a 50% interest in the Van Wie Gas Stove Company of Cleveland, Ohio. He persuaded them to move to Rockford, Illinois, operating as Secretary and Treasurer to company president P.G. Van Wie. As the U.S. moved into Depression in the early 1890s, the Van Wie plant passed into trusteeship. George Roper was to operate as trustee until the obligations against the plant were paid off, at which time the Gas Stove Works would become his sole property. All debts were liquidated fully on September 1, 1894. Ten days later, the institution was entirely destroyed by fire. Salvaged and rebuilt as the Eclipse Gas Stove Company, the business grew steadily, expanding to include the American Foundry Company in 1901, and the Trahern Pump Company in 1906. Traherns hand operated well pumps had been helping to build the American dream since 1857. Within a few years the company was pioneering new pump developments, and becoming a major supplier to the rapidly growing petroleum industry. In 1919, George D. Roper merged all of his companies into one company named the George D. Roper Corporation. He passed away In 1925, and left the presidency of the corporation to his son, Mabon P. Roper. The company survived the Great Depression of 1929, and during World War II developed diesel engine lubricating pumps for war plants and naval vessels. They also manufactured projectiles and ammunition boxes. Mabon P. Roper died in 1942, ending the Roper family line. He was succeeded by Stanley Hobson, who continued the Roper tradition of quality and dependability.

From Legacy to Leadership


In the two decades that followed, the George D. Roper Corporation grew and evolved. They sold the original Stove Company in 1957, and renamed the remaining pump portion Roper Hydraulics Inc. In 1959, Roper Hydraulics acquired O.E. Szekely & Co., pump specialists located in Commerce, Georgia, where Roper Pump Company maintains operations to this day. In 1961, Roper Hydraulics changed their name to Roper Industries Inc. Roper Industries became a publicly traded company in 1992 (NYSE symbol: ROP). Roper Pump Company is a division of their Industrial Technology Group.

Through continued product line expansion, Roper Pump Company has secured its position as a leader in the transport industry and is gaining influence in the chemical industry with unique and reliable stainless steel products. Today, Roper Pump Company offers its innovation, state-of-the-art technology, quality and value, combined with a tradition of reliability that dates back 150 years.

ISO9001:2000 Certified

ROPER PUMPS - THE LEADING FORCE behind liquids

since 1857

The Total Pumping Solution

3600 Series

Heavy Duty Pumps


General Purpose Pumps for Mixing, Blending, Recirculating, Fixed and Mobile Transfer Up to 468 GPM Up to 125 PSI
These pumps operate smoothly and with equal efficiency in either direction of rotation. They effectively handle heavy, viscous materials such as asphalt, molasses, roofing compounds, and printing inks, as well as fuel oils, gasolines, and similar thin liquids. Pumps can be supplied in several materials of construction, with or without built-in relief valves. Pumps can be assembled either hi-drive or low-drive, and are available with conventional packed box or lapped-face mechanical shaft seal. They can be direct driven or driven through a built-in gear reduction with a wide range of ratios. These pumps operate equally well regardless of the mounting configuration or the direction of rotation. MATERIALS OF CONSTRUCTION Standard Fitted Housing ...............................................Cast Iron Gears ...................................................Cast Iron Bearings ...............................................Bronze Shafts...................................................Steel Optional Materials* Gears ...................................................Bronze Stainless Steel Delrin Bearings ...............................................Iron Carbon Shafts ..................................................Stainless Steel
*some of the optional materials may not be available for all sizes

FEATURES
Quiet-Running Helical Gears I Heat treated cast-iron pumping gears are accurately machined for quiet, efficient operation and long life. I The pumping gears are keyed to their shafts with a sliding fit and are easily replaced. I Accurate machining insures proper meshing, and reduces friction and vibration. Long-Lasting Bearing Surfaces I Bearings are special wear-resistant, high-lead bronze. Iron and carbon bearings are available. I Four heavy duty sleeve bearings give positive support to pumping gears and insure long, efficient service. I Bearing grooves allow circulation of the liquid being pumped for lubrication & control of bearing temperature. I Outboard drive shaft bearing supports external radial loads and absorbs most thrust loads. Precision-Ground Shafts I The steel shafts are induction hardened in the bearing and packing areas and are precision ground to exacting standards for maximum life. I Hardened stainless steel shafts available. Rugged Housing I Standard castings are cast iron. I Precise manufacturing tolerances provide minimum clearances for maximum pumping efficiency. I Large, hardened steel dowel pins insure positive alignment between the faceplate, case, and backplate.

THE LEADING FORCE behind liquids since 1857

3600 Series

Capacities & Nomenclature


THEORETICAL CAPACITY
500 450 400 Flow Rate (GPM) 350 300 250 200 150 100 50 0 200 300 400 500 600 Pump Speed (RPM) 700 800 900
3X35
3X22 3X17
3X4 8

3X5

3X43

3X32

3X11

NOMENCLATURE 3611 G H B F R V
3 Port Location 3 Right Angle Ports 4 Straight Through Ports 5 Triple Lip Seal 6 Packing 7 Mechanical Seal 8 Lip Seal with Ball Bearings 11 11 Gal/100 Rev 35 35 Gal/100 Rev 17 17 Gal/100 Rev 43 43 Gal/100 Rev 22 22 Gal/100 Rev 48 52 Gal/100 Rev 32 32 Gal/100 Rev 58 58 Gal/100 Rev Pump Head without Outboard Ball Bearing Tapped Port Case with Outboard Ball Bearing Flanged Ports with Outboard Bearing Flanged Ports with Outboard Bearing and Relief Valve Flanged Ports with Outboard Bearing, Relief Valve, and Gear Reducer Tapped Ports, No Outboard Bearing, Mounting for Hyd. Drive or CCD Bracket Flanged Ports, No Outboard Bearing, Mounting for Hyd. Drive or CCD Bracket Flanged Ports, No Outboard Bearing, Mounting for Hyd. Drive or CCD Bracket, and Relief Valve

Seal Option

11

Size

H HB HBF HBFRV GHBFRV BH BHF BHFRV

* There are over 40 basic configurations and several thousand custom designs. Please consult your local Roper distributor to decide which configuration best fits your needs

Configuration*

ROPER PUMPS - THE LEADING FORCE behind liquids

since 1857

Key Components

BEARINGS
Four heavy duty sleeve bearings give positive support to pumping gears and insure long, efficient service. A special wear-resistant, high-lead bronze bearing is standard on 3600 Series Pumps. For thin non-abrasive liquids we offer optional carbon bearings as well as iron bearings for abrasive liquids. The bearings are grooved to allow circulation of the liquid being pumped for lubrication & control of bearing temperature.

GEARS
The helical pumping gears are machined from heat treated cast iron because of its excellent wear resistance. For chemical pumping applications, the standard gears can be replaced with stainless steel or bronze. An optional Delrin idler gear can be used for quieter operation when running thin liquids.

SHAFTS
Standard steel shafts are induction hardened in the bearing and packing areas, and are precision ground to exacting standards for maximum life. Hardened stainless steel shafts are also available upon request.

HOUSING
Our rugged cast-iron housings are manufactured to precise tolerances, providing minimum clearances for maximum pumping efficiency. Large, hardened steel dowel pins ensure positive alignment between the faceplate, case, and backplate.

GASKETS
3600 Series Pumps come standard with fiber gaskets that are used up to 212F/100C. For higher temperature applications (up to 450F/232C) we offer other optional gasket materials.

Delrin is a registered trademark of E. I. du Pont de Nemours and Company.

3600 Series

Relief Valves & Jacketing


RELIEF VALVE
In the event of overpressure situations, our adjustable relief valve protects personnel and equipment by returning liquids to the suction side of the pump until conditions are corrected. Various spring sizes can be specified to handle a wide range of operating conditions. Ropers inverted poppet relief valve is designed without close fitting guides that can clog and cause excessive pressures when the valve does not open freely. The valve will provide protection in only one direction of rotation. However it can be positioned easily to either side of the pump to accommodate flow direction.

BI-DIRECTIONAL RELIEF VALVE


Ropers integral bi-directional pressure relief valve offers reliable protection of your personnel and equipment, regardless of which direction you are pumping. You can reverse flow without disabling pressure relief operability, or compromising operator safety. Based on our rugged and time proven standard relief valves, this offers you a lighter weight, lower cost alternative compared to externally plumbed systems.

JACKETING
Whether the fluid to be pumped must be heated, cooled, or maintained at a specific temperature, a jacketed Roper pump will handle difficult-topump materials such as Bunker C, molasses, asphalt mixes, refined sugars, creosote, printing ink, and other viscous fluids which require temperature control for satisfactory handling. Roper jacketed pumps provide efficient heat transfer to the packing, seal relief valve, bearing areas, and endplates of the pump. The jackets are suitable for use with steam, hot or cold water, heat transfer oil, etc., as heating or cooling mediums. Jacketing is available on the faceplate only, backplate only, or on both.

ROPER PUMPS - THE LEADING FORCE behind liquids

since 1857

Pump Seals

MECHANICAL SEAL
Mechanical seals are for those applications where product leakage is unacceptable. Under proper conditions the mechanical seal has a longer service life than the packed box and does not require adjustment. The standard mechanical seal is an elastomeric bellows type seal. A PTFE wedge seal is also available.

PACKED BOX
Our standard packing is suited for general purpose applications, and is easily replaced with split ring packing. For best performance, the gland should be adjusted to allow slight seepage. Standard packing is graphite, with several optional packing materials available for applications involving high temperatures or mildly corrosive liquids, or those requiring compatibility with food products.

Need More Seal Options?


OUR Z SERIES...
Based on our 3600 Series, the Roper Z Series features a larger seal chamber in a two-piece backplate that allows for virtually unlimited options, and facilitates easy seal maintenance. Many parts are interchangeable with the 3600 Series.

TRIPLE LIP SEAL


Offering the same high degree of sealing reliability as a mechanical seal, triple lip seals are better suited for viscous products that tend to set up while the pump is idle, such as resins, glues and paints. The Teflon filled elastomer lips create an effective barrier to product leakage, and will move freely upon resumption of pumping a thickening substance. In cases where extreme circumstances can cause catastrophic failure of mechanical seals, the resilient nature of the triple lip elastomer makes it relatively immune to sudden failure.
Teflon is a registered trademark of E. I. du Pont de Nemours and Company.

3600 Series

Gear Reduction (GHB) Unit


Totally enclosed and running in oil, the reduction gears are made of hardened steel to assure longer life. Antifriction bearings are used throughout. Three interchangeable gear ratios are available in each size. For additional ratios look at using a Roper CCD bracket and an industrial standard gearmotor.
PERFORMANCE CHARTS
Performance figures show maximum horsepower requirements for minimum rated gallons per minute at the various speeds, viscosities and pressures. The charts are intended as a guide for conditions at the pump. In determining the proper conditions of operation for the pump, many factors must be considered including inlet conditions, liquid characteristics, and temperature. If there is any question concerning these charts or the recommended operating conditions, please consult your Roper distributor, district representative, or the home office.
GEAR RATIOS AND CAPACITIES FOR GHB UNITS
Motor RPM 1150 11 through 22 Gear Ratio 4.60:1 3.94:1 3.20:1 4.60:1 3.94:1 3.20:1 4.60:1 Pump RPM 250 290 360 380 445 545 750 Max. Permissible HP 5.5 6.5 8.0 8.5 10.0 10.0 10.0

1750

3450*

*3450 RPM motors are used in handling low viscosity lubricating liquids.

SIZE
Pump PSI 25 50 100 125 25 50 100 125 25 50 100 125

RPM
SSU GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP 30 25 .7 23 1.1 100 26 .7 25 1.1 23 1.9 22 2.2 40 .8 38 1.4 34 2.5

250 RPM
1000 10,000 27 27 .9 1.3 27 27 1.3 1.7 26 27 2.1 2.5 26 27 2.4 2.8 41 42 1.1 1.8 41 42 1.7 2.4 40 41 2.9 3.6 39 41 3.4 4.1 55 55 1.4 1.9 54 55 2.3 2.8 53 55 3.8 4.3 53 55 4.5 5.0 30 29 .9 27 1.3

290 RPM
100 30 .9 29 1.3 27 2.2 26 2.7 47 1.0 45 1.6 41 3.0 1000 31 1.2 31 1.5 30 2.4 30 2.9 48 1.3 48 1.9 47 3.3 46 4.0 63 1.7 62 2.6 61 4.5 61 5.5 10,000 31 1.5 31 1.9 31 3.0 31 3.5 49 2.2 49 2.8 48 4.2 48 4.9 63 2.5 63 3.4 63 5.3 63 6.3 30 37 1.1 35 1.7

360 RPM
100 38 1.1 37 1.7 35 2.8 34 3.3 59 1.2 57 2.1 53 3.8 51 4.6 77 2.0 76 3.1 74 5.4 73 6.5 1000 39 1.4 39 2.0 38 3.1 38 3.6 60 1.8 60 2.7 59 4.4 58 5.2 79 2.6 78 3.7 77 6.0 77 7.1 10,000 39 2.2 39 2.8 39 3.9 39 4.4 61 3.0 61 3.9 60 5.6 60 6.4 79 3.9 79 5.0 79 7.3 79 8.4 30 40 1.1 38 1.7 33 2.9

380 RPM
100 41 1.1 40 1.7 38 2.9 37 3.5 62 1.3 60 2.3 56 4.2 54 5.0 81 2.2 80 3.3 78 5.7 77 6.9 1000 10,000 42 42 1.5 2.3 42 42 2.1 2.9 41 42 3.3 4.1 41 42 3.9 4.7 63 64 1.9 3.3 63 64 2.9 4.3 62 63 4.8 6.2 61 63 5.6 7.0 83 83 3.0 4.3 82 83 4.1 5.4 81 83 6.5 7.8 81 83 7.7 9.0 30 47 1.4 45 2.1 40 3.5

445 RPM
100 48 1.4 47 2.1 45 3.5 44 4.2 73 1.7 71 2.9 67 5.0 65 6.0 95 2.7 94 4.1 92 6.8 91 8.3 1000 49 2.0 49 2.6 48 4.0 48 4.7 74 2.5 74 3.7 73 5.8 72 6.8 97 3.5 96 4.9 95 7.6 95 9.1 10,000 30 58 1.9 56 2.7 51 4.4 48 5.4 88 2.3 83 3.6 80 6.3 80 7.5 116 3.2 114 4.8 108 8.2 106 10.2

545 RPM
100 59 1.9 58 2.7 56 4.4 55 5.4 90 2.3 88 3.6 84 6.3 82 7.5 117 3.2 116 4.8 114 8.2 113 10.2 1000 60 2.7 60 3.5 59 5.2 59 6.2 91 3.6 91 4.9 90 7.6 89 8.8 119 4.4 118 6.0 117 9.4 117 11.4 10,000 30 80 2.8 78 3.9 73 6.3 70 7.5 123 3.5 118 5.4 115 9.0 115 10.8 162 5.1 161 7.3 154 12.0 152 14.7

750 RPM
100 81 2.8 80 3.9 78 6.3 77 7.5 125 3.5 123 5.4 119 9.0 117 10.8 163 5.1 162 7.3 160 12.0 159 14.7 1000 10,000 82 3.8 82 4.9 81 7.3 81 8.5 126 6.0 126 7.9 125 11.5 124 13.3 165 7.2 164 9.4 163 14.1 163 16.8

11

17

38 .8 33 1.4

45 1.0 40 1.6

22

52 1.1 50 2.0 44 3.5

53 1.1 52 2.0 50 3.5 49 4.2

60 1.3 58 2.3 52 4.2 50 5.2

61 1.3 60 2.3 58 4.2 57 5.2

57 1.2 52 2.1 49 3.8 49 4.6 7 2.0 74 3.1 68 5.4 66 6.5

60 1.3 55 2.3 52 4.2 52 5.0 80 2.2 78 3.3 72 5.7 70 6.9

71 1.7 66 2.9 63 5.0 63 6.0 94 2.7 92 4.1 86 6.8 84 8.3

ROPER PUMPS - THE LEADING FORCE behind liquids

since 1857

GEAR RATIOS AND CAPACITIES FOR GHB UNITS


Motor RPM 1150 32 through 58 Gear Ratio 5.66:1 4.88:1 4.26:1 5.66:1 4.88:1 4.26:1 5.66:1 Pump RPM 203 235 270 309 360 410 609 Max. Permissible HP 8.5 10.0 11.0 13.0 15.0 15.0 15.0

1750

3450*

*3450 RPM motors are used in handling low viscosity lubricating liquids.

SIZE
Pump

RPM
PSI 25 50 100 125 25 50 100 125 25 50 100 125 25 50 100 125 25 50 SSU GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP GPM HP 30 54 1 41 2

203 RPM
100 57 1.2 47 2.2 1000 10,000 61 65 1.4 1.8 55 59 2.4 2.8 44 52 4.4 4.8 49 5.8 73 75 2.8 4.3 71 73 3.9 5.4 68 71 6.0 7.5 65 70 7.2 8.7 83 85 2.3 3 77 81 3 3.7 62 72 5.5 6.2 56 69 6.6 7.3 101 103 3.2 3.8 93 99 4.7 5.3 88 8.5 30 64 1.3 51 2.3

235 RPM
100 67 1.5 57 2.5 1000 71 1.8 66 2.8 54 5.1 46 6.6 85 3.3 83 4.6 80 7.0 77 8.3 97 2.8 91 4 76 7 70 8.5 118 3.9 110 5.6 10,000 75 2.3 70 3.3 62 5.6 59 7.1 87 5.2 85 6.5 83 8.9 82 10.2 99 3 95 4.2 86 7.2 83 8.7 120 4.6 116 6.3 105 10.0 101 11.7 143 7.0 142 9.0 141 13.4 140 15.4 30 75 1.7 62 3

270 RPM
100 78 1.9 68 3.2 47 5.9 1000 82 2.5 77 3.8 65 6.5 57 8 98 3.9 96 5.3 93 8.2 90 9.7 112 3.3 106 4.9 91 8.4 85 9.5 136 4.7 128 6.7 10,000 86 3 81 4.3 73 7 70 8.5 100 6.2 98 7.6 96 10.5 95 12.0 114 3.7 110 5.3 101 8.8 98 9.9 138 5.7 134 7.7 123 11.1 119 14.0 164 9.8 163 12.1 162 16.9 161 19.4 30 88 2.1 75 3.5

309 RPM
100 91 2.3 81 3.7 60 6.7 1000 10,000 95 99 2.8 3.4 89 93 4.2 4.8 78 86 7.2 7.8 70 83 8.7 9.3 112 114 4.6 7.5 110 112 6.2 9.1 107 110 9.6 12.5 104 109 11.2 14.1 128 131 3.7 4.4 123 127 5.7 6.4 108 118 9.7 10.4 102 115 11.2 11.9 156 158 5.7 6.9 148 154 8.1 9.3 132 143 12.7 13.9 139 16.2 186 188 6.7 11.0 185 187 9.4 13.7 182 186 14.9 19.2 180 185 17.8 22.1 30 104 2.8 91 4.5 65 7.5 45 9.2 129 5.3 125 7.1

360 RPM
100 107 3 97 4.7 76 7.7 65 9.4 130 5.3 127 7.1 1000 111 3.6 106 5.3 94 8.3 86 10 131 5.7 129 7.5 126 11.4 123 13.4 150 4.7 145 6.8 130 11.6 124 14.1 183 7.0 175 9.6 159 15.1 10,000 115 4.3 110 6 102 9 99 10.7 133 9.4 131 11.2 129 15.1 128 17.1 153 5.6 149 7.7 140 12.5 137 15 185 8.5 181 11.1 170 16.6 166 19.2 219 13.5 218 16.8 217 23.1 216 26.3 30 120 3.5 107 5.5 81 9.5

410 RPM
100 123 3.7 113 5.7 92 9.7 81 11.5 149 6.2 146 8.4 1000 127 4.3 122 6.3 110 10.3 102 12.1 150 6.7 148 8.9 145 13.4 142 15.6 172 5.7 166 8.4 151 13.5 145 16.2 209 8.4 201 11.6 185 17.7 176 20.8 248 10.2 247 13.8 244 21.0 242 24.7 10,000 131 5.2 126 7.2 118 11.2 115 13 30 184 6 171 9 145 14.5

609 RPM
100 187 6.7 177 9.7 156 15.2 145 17.8 222 10.9 219 14.2 1000 10,000 191 195 8 10 185 189 11 13 174 182 16.5 18.5 166 179 19.1 21.1 223 11.9 221 15.2 218 21.8 215 25.2 257 260 11 14 252 256 14.8 17.8 237 247 22.2 25.2 231 244 26 29 312 314 16.8 19.7 304 310 19.3 24.2 288 299 28.4 33.3 279 295 32.9 37.3 369 18.8 368 24.3 365 35.0 363 40.5

32

35

71 2.6 67 3.7

72 2.6 69 3.7 61 5.8

83 3.1 79 4.4

84 3.1 81 4.4 73 6.8

96 3.7 92 5.1 82 8.0

43

76 1.8 62 2.5

79 2 68 2.7

90 2 76 3.2

93 2.3 82 3.5

105 2.4 91 4

97 3.7 94 5.1 86 8.0 83 9.5 108 2.9 97 4.5 73 8

110 4.4 106 6.0 96 9.4

111 4.4 108 6.0 100 9.4

148 6.2 144 8.4

221 10.9 217 14.2

122 3 108 5

125 3.2 114 5.2 90 9.2

94 2.5

97 2.8

111 3.0

48

114 3.4 103 5.1

129 3.7

132 3.9 121 5.9

149 4.4 133 6.8

152 4.7 141 7.1

144 3.7 130 5.8 95 10.6 55 13.1 176 5.4 160 8.0

147 3.9 136 6 112 10.8 97 13.3 179 5.9 168 8.5

165 4.4 151 7.1 116 12.2

202 6.3 186 9.5

168 4.9 157 7.6 133 12.7 118 15.4 205 6.8 194 10.0

58

116 2.7 106 5.6

119 2.7 114 5.6

100 125

121 2.8 120 5.7 117 9.4 115 11.1

123 4.8 122 7.7 121 11.4 120 13.1

136 4.3 126 6.3

139 4.3 134 6.3

141 4.6 140 6.6 137 11.0 135 13.0

157 5.0 147 7.3

160 5.0 155 7.3

162 5.5 161 7.8 158 12.6 156 15.1

181 6.0 171 8.7

184 6.0 179 8.7

212 6.3 202 10.1

215 7.1 210 10.4

217 8.2 216 11.5 213 17.8 211 21.0

243 8.3 233 11.9

246 8.4 241 12.0

174 7 170 9.7 161 14.8 158 17.5 211 10.3 207 13.5 196 19.6 192 22.7 250 18.0 249 21.6 248 28.8 247 32.5

251 8.2 237 12 202 19.4 182 23.2 305 10.9 209 15.4

254 9 243 12.8 219 20.2 204 24 308 12.0 297 16.5 266 25.6

3600 Series

Direction of Rotation
Rotation direction is determined when facing the drive shaft. The diagrams will serve as a helpful basis for you to determine the direction of rotation wanted according to your piping system. We can build the pump at the factory to meet your installation requirements. If the pump build is not specified, it will be shipped the standard W configuration. Once in the field, if you need to change the configuration, it can easily be done by just disassembling the pump and rebuilding it to your desired arrangement. No new parts are needed.
Note: top picture in each section is a standard pump and the bottom picture is the same pump with gear box added.

3600 SERIES (90) WITH HIGH DRIVE


H, HB, B, BH W
CW CCW

X
CW

Y
CCW

CCW

3600 SERIES (90) WITH LOW DRIVE


LW H, HB, BH
CW CCW

GHB

CW

CCW

CW

LX
CW

LY
CCW

LZ

GHB

CCW

CCW CW CW

4600 SERIES (180) WITH HIGH DRIVE


W H, HB, BH
CW CCW

4600 SERIES (180) WITH LOW DRIVE


Z
CW

LW
CCW

LZ

CCW

CW

GHB

CCW

CW

10

ROPER PUMPS - THE LEADING FORCE behind liquids

since 1857

Base Mounted Units


CLOSE COUPLED DRIVES (CCD)
The close coupled drive configuration provides an enhanced level of safety in a compact package. Guards and alignment are not required because this complete drive package easily mounts to DIN flanged gear motors. Since the CCD bracket creates a unified system from the motor to the pump, the baseplate become an optional component to the system. These units will attach to our standard 3600 BH pumps.

ROPER GHB GEARBOX


The versatile GHB gearbox configuration features a built-on gear reduction unit that allows minute adjustments for various driver shaft heights. This feature makes alignment to the motor shaft very simple. The carefully selected ratios convert standard motor speeds to ranges suitable for most pumping applications. See pages 8-9 for more information on available gear ratios.

INDUSTRIAL STANDARD
Using an industrial standard gearbox offers virtually unlimited gear ratio options and the ability to easily change pump speeds by simply changing the gearbox. Roper Pump offers extensive expertise in spacing, mounting and aligning the complete drive package of motor, gearbox and pump.

3600 Series

11

3600 SERIES - 90 Ports

GHB 4600 SERIES - Thru Ports 180 GHB


12

H & HB

H & HB

ROPER PUMPS - THE LEADING FORCE behind liquids since 1857

IN [mm]
NO OUTBOARD BEARING

3600 SERIES
H & HRV (SPEC G)

D C HIGH E

N
2.58 [65]

NM

O
10.75 [273] 11.54 [293] 10.75 [273] 11.54 [293] 12.16 [308] 15.63 [397] 16.66 [423] 17.35 [440] 10.75 [273] 11.54 [293] 10.75 [273] 11.54 [293] 12.16 [308] 15.63 [397] 16.66 [423] 17.35 [440] 10.75 [273] 11.54 [293] 10.75 [273] 11.54 [293] 12.16 [308] 15.63 [397] 16.66 [423] 17.35 [440]

P
3.62 [91] 4.3 [109] 3.62 [91] 4.3 [109] 6.41 [162] 6.88 [174] 7.91 [200] 8.1 [205] 3.62 [91] 4.3 [109] 3.62 [91] 4.3 [109] 6.41 [162] 6.88 [174] 7.91 [200] 8.1 [205] 3.62 [91] 4.3 [109] 3.62 [91] 4.3 [109] 6.41 [162] 6.88 [174] 7.91 [200] 8.1 [205]

R
19.57 [497]

KEY

PORTS
2 NPT TAPPED

11 17 22 35 58

15.97 HF & HFRV (SPEC G) [405] H & HRV (SPEC G) 6.44 [163] 0.88 [22] 2.75 0.75 0.56 5 [69] [19] [14] [127] 16.72 HF & HFRV (SPEC G) [424] HF & HFRV (SPEC G) 18.59 [472] H & HRV 19.53 [496] 9.25 HF & HFRV [234] 22.51 HF & HFRV (SPEC G) [571] HB & HBRV HBF & HBFRV 19.32 [490] 6.44 [163] 20.07 [509] 21.57 [547] 23.69 [601] 9.25 [234] 26.53 [673] 20.47 [519] 6.44 [163] 21.97 [558] 23.47 [596] 25.88 [657] 9.25 [234] 28.72 [729] 0.88 [22] 0.88 [22]

10.34 [262] 1.83 [46] 2.2 [55] 11.46 [291] 11.96 [303] 13.52 [343]

1.06 [26] 20.33 [516]

4 [101]

2 NPT FLANGED .25 SQ X 1.50 N/A N/A 2 NPT TAPPED 2 NPT FLANGED 3 NPT FLANGED 3 NPT TAPPED .38 SQ X 1.62 3 NPT FLANGED 4 NPT FLANGED 2 NPT TAPPED

22.19 [563] 23.04 [585] 26.02 [660] 22.92 [582] 1 [25] 23.67 [601] 25.17 [639] 27.2 [690] 30.04 [763] 24.07 [611] 1 [25] 25.57 [649] 27.07 [687] 29.39 [746] 32.23 [818] 1.25 [31] 1.25 [31]

4.41 [112] 6 [152] 6.28 [159]

WITH OUTBOARD BEARING

11 17 22 35 58

HB & HBRV HBF & HBFRV HBF & HBFRV HB & HBRV HBF & HBFRV HBF & HBFRV GHB & GHBRV

2.15 5.19 1.5 0.69 9.25 [54] [131] [38] [17] [234] 2.29 [58] 0.75 3.45 [19] [87] 0.62 2.75 [15] 0.56 5 [69] [14] [127] 0.75 [19] 2.7 [68]

1.44 [36]

13.69 [347]

4 [101]

2 NPT FLANGED 2 NPT TAPPED .25 SQ X 1.50 2 NPT FLANGED N/A N/A 3 NPT FLANGED 3 NPT TAPPED 3 NPT FLANGED .38 SQ X 2.25 4 NPT FLANGED 2 NPT TAPPED

14.4 [366] 5.19 1.5 0.69 9.25 3.25 [131] [38] [17] [234] [82] 16.12 [409] 17.54 [445] 0.75 [19] 0.62 2.75 [15] 0.56 5 1.74 [69] [14] [127] [44] 0.75 [19] 14.83 [376] 15.58 [395] 16.33 [414] 18.31 [465] 19.73 [501]

4.41 [112] 6 [152] 6.28 [159]

WITH GEAR REDUCTION UNIT

11 17 22 35 58

GHBF & GHBFRV GHB & GHBRV GHBF & GHBFRV GHBF & GHBFRV GHB & GHBRV GHBF & GHBFRV GHBF & GHBFRV

4 [101]

3.523 10.24 [89] [260] .25 SQ X 1.50

2 NPT FLANGED 2 NPT TAPPED 2 NPT FLANGED

4.41 [112] 6 [152] 6.28 [159]

3 NPT FLANGED 3 NPT TAPPED 4.189 11.25 .25 SQ X 2.00 3 NPT FLANGED [106] [285] .25 SQ X 1.50 4 NPT FLANGED

5.19 1.5 0.69 9.25 2.29 [131] [38] [17] [234] [58]

IN [mm]
WITH REDUCTION WITH OUTBOARD NO OUTBOARD UNIT BEARING BEARING

4600 SERIES
11 17 22 58 11 17 22 58 11 17 22 58
HF & HFRV (SPEC G) HF & HFRV (SPEC G) HF & HFRV (SPEC G) HF & HFRV (SPEC G) HBF & HBFRV HBF & HBFRV HBF & HBFRV HBF & HBFRV GHBF & GHBFRV GHBF & GHBFRV GHBF & GHBFRV GHBF & GHBFRV

D C HIGH LOW E
15.97 [405] 16.72 [424] 18.59 [472] 22.51 [571] 19.32 [490] 20.07 [509] 21.57 [547] 26.53 [673] 20.47 [519] 21.97 [558] 23.47 [596] 28.72 [729]

G
0.62 [15]

NM
10.34 [262]

P
4.17 [105] 4.41 [112] 4.85 [123] 8.1 [205] 4.17 [105] 4.41 [112] 4.85 [123] 8.1 [205]

R
19.57 [497] 20.33 [516] 22.19 [563] 26.02 [660] 22.92 [582] 23.67 [601] 25.17 [639] 30.04 [763] 24.07 [611] 25.57 [649] 27.07 [687] 32.23 [818]

KEY

PORTS
2 NPT TAPPED

6.44 3.56 2.75 [163] [90] 0.88 [69] [22] 9.25 5 [234] [127] 5.19 [131]

6.44 3.56 2.75 [163] [90] 0.88 [69] [22] 9.25 5 [234] [127]

2.58 [65] 0.56 5 1.83 0.75 [14] [127] [46] [19] 2.2 [55] 1.5 0.69 9.25 2.29 [38] [17] [234] [58] 0.62 3.8 [15] [96] 0.56 5 0.75 [14] [127] 3.05 [19] [77] 0.69 9.25 3.25 [17] [234] [82]

9.44 [239]

1.06 [26]

.25 SQ X 1.50 3 NPT FLANGED N/A N/A N/A 4 NPT FLANGED .38 SQ X 1.62 2 NPT TAPPED

11.46 [291] 13.52 9.25 [343] [234] 13.69 [347]

1.44 [36]

5 [127]

1 [25]

N/A

N/A

N/A

.25 SQ X 1.50 3 NPT FLANGED

5.19 1.5 [131] [38] 0.62 [15] 6.44 3.56 2.75 [163] [90] 0.88 [69] 0.75 [22] [19] 9.25 5 [234] [127]

0.56 5 1.74 [14] [127] [44]

5.19 1.5 0.69 9.25 2.29 [131] [38] [17] [234] [58]

14.44 [366] 17.54 9.25 [445] [234] 14.83 [376] 15.58 5 [395] [127] 16.33 [414] 19.73 9.25 [501] [234]

1.25 [31] 3.523 10.24 [89] [260] N/A 4.189 11.25 [106] [285]

4 NPT FLANGED .25 SQ X 1.50 2 NPT TAPPED

4.3 [109]

1 [25]

.25 SQ X 2.00

3 NPT FLANGED

8.1 [205]

1.25 [32]

4 NPT FLANGED

3600 Series

13

3600 SERIES - Angled Gears

IN [mm]
WITH GEAR WITH OUTBOARD NO OUTBOARD REDUCTION UNIT BEARING BEARING

3600 SERIES ANGLED GEARS

C
20.48

NM
12.25 13.07 13.66 15.44 16.29 17.38 17.59 18.40 19.00

R
21.40 23.02 24.21 24.58 26.24 27.93 26.74 28.35 29.55

PORT
3 NPT FLANGE 3 NPT FLANGE 4 NPT FLANGE 3 NPT FLANGE 3 NPT FLANGE 4 NPT FLANGE 3 NPT FLANGE 3 NPT FLANGE 4 NPT FLANGE

32 43 48 32 43 48 32 43 48
GHBF & GHBFRV HBF & HBFRV HF & HFRV

22.10 23.19 23.67 25.32 27.02 25.82 27.43 28.63

14

ROPER PUMPS - THE LEADING FORCE behind liquids

since 1857

Flanges
A variety of fittings makes these pumps adaptable to almost all mounting requirements. With these flanges, unions and many pipe fittings are unnecessary, since the pipe and flange can be connected before bolting the flange to the pump.

PUMP SIZE

FITTING TYPE Straight Flange (Std.) Flanged Elbow (vertical) Flanged Elbow (horizontal) Straight Flange (Std.) Flanged Elbow Flanged Elbow Straight Flange Straight Flange (Std.) Flanged Elbow Flanged Elbow Straight Flange Straight Flange Straight Flange Straight Flange (Std.) Flanged Elbow Straight Flange Straight Flange (Std.) Straight Flange (Std.) Flanged Elbow Straight Flange Straight Flange Straight Flange (Std.) Flanged Elbow Flanged Elbow Straight Flange (Std.)

PORT SIZE 2" 2" 2" 2" 2" 3" 212" 3" 2" 3" 212" 2" 212" 3" 3" 4" 3" 3" 3" 2" 3" 4" 3" 4" 4"

ASSEMBLY NUMBER N14-14 N14-15 N14-16 N14-17 N14-19 N14-20 N14-62 N14-18 N14-19 N14-20 N14-62 N14-28 N14-29 N14-30 N14-31 N14-59 N14-121 N14-76 N14-77 N14-57 N14-21 N14-22 N14-23 N14-24 N14-26

FLANGE PART NO. P23-30 P23-32 P23-31 P23-12 P23-60 P23-36 P23-72 P23-35 P23-60 P23-36 P23-72 P23-18 P23-22 P23-10 P23-59 P23-19 P23-150 P23-35 P23-36 P23-18 P23-10 P23-19 P23-59 P23-37 P23-52

A
7

B 3 316 3 716 3 716 4 716 3 716 4 716 4 14 4 716 4 16


7

C 11116 11516 1 1516 2 38 1 1516 2 38 2 18 2 38 2 8


3

D 31316 212 2 716 4 316 2 716 4 316 4 58 4 316 4 316 4 58 5 38 -

3611 4611 3617

8 -

8 1 18
7

4617

1 18 1 18 1 18 1 18 1 18 1516 1 18 1 8
1

3622 3632 3635 4622 3643 3648 3658, 4658

1 18 1 18 1516 15

4 14 5 12 -

2 18 2 34 -

16

Each assemby includes: flange, gasket, and hardware. For simplicity, the pump sizes above are only shown with PACKING (6 in the model number). Flanges are interchangeable with 3500 (triple lip seal), 3600 (packing) and 3700 (mechanical seal) variations.

3600 Series

15

THE LEADING FORCE behind liquids since 1857


Roper Pump Company is a global supplier of high quality positive displacement pumps, designed to handle a broad range of industrial applications. In addition to helical gear pumps, progressing cavity pumps and triple screw pumps, we design and develop numerous custom pumps for customers with unique and demanding applications. From a small pump company founded in 1857, Roper Pump Company has grown into a technological leader. With a large installed base, we have both the knowledge and experience to help you solve your most challenging pumping problemsand our strong global distribution network ensures that your needs are met on time, every time.

Our Markets

INDUSTRIAL Roper Pump Companys rugged and dependable range of positive displacement pumps provides versatile pumping solutions for even the most challenging industrial applications.

TRANSPORT With over a century of experience in liquid cargo transfer, Roper Pump Company has always been trusted to load and unload your tankers quickly and safely.

POWER GENERATION For reliable operation of engines, compressors and turbines, thousands of customers depend on Roper Pump Company fuel pumps, lube pumps and liquid fuel flow dividers.

OIL & GAS Roper Pump Company has numerous pumping solutions from the well to the refinery. Our industry leading DragonSlayer Power Sections allow mud motors to run longer at unprecedented temperatures and depths.

Roper Pump Company


PO Box 269 Commerce, GA 30529 USA Customer Service: (706) 336-3359 Technical Support: (706) 336-3334 Fax: (706) 335-5490 sales@roperpumps.com www.roperpumps.com 2007 by Roper Pump Company Roper Pumps and DragonSlayer are registered trademarks of Roper Pump Company. THE LEADING FORCE behind liquids is a trademark of Roper Pump Company DOC# PB-3600-E-R1

Das könnte Ihnen auch gefallen