Sie sind auf Seite 1von 1

12.

5mmcement fibre
board
38x50mmvertical treated
timber battens
Vapour barrier
242mmprefabricated
composite wall:
17mmtimber panel;
140mmwood fibre insulation;
85mmsolid timber wall
Additional 85mmsolid timber
wall
47x125mmtimber studs
20mmlarch timber cladding
Rainwater downpipe
Roof overhang
Marvin AluClad timber door
with triple glazed unit
85mmsolid timber wall
Triple glazing in 50x50mm
steel bracket, glued
Built-in cupboards
Code 4 lead cladding
(see Note 6)
Geotec underlay
15mmmarine plywood
38x50mmvertical treated
timber battens
242mmprefabricated
composite wall:
17mmtimber panel;
140mmwood fibre insulation;
85mmsolid timber wall
Steel door to garden
20x100mmlarch
horizontal timber
cladding
47x125mmtimber studs
Rainwater downpipe
Additional 85mmsolid
timber wall
Roof overhang
20x100mmlarch
horizontal timber
cladding boards
Triple glazing in steel
z-angle, glued
47x125mmtimber stud
30mm tmber corner
piece
242mmprefabricated
composite wall:
17mmtimber panel;
140mmwood fibre insulation;
85mmsolid timber wall
Additional 85mmsolid timber
wall
38mmrigid insulation
board
Code 4 lead cladding
(see Note 6)
Geotec underlay
15mmmarine plywood
Triple glazing in 68x40mm
steel l-bracket, glued
45mmrigid insulation board
20mmcharred accoya
cladding, vertical
Double skin precast
concrete unit with internal
steel diaphragm, curved
Preformed stainless steel
windowsill, insulated
225mmwood fibre
insulation
3
2
5
7
5
A
1235
75 Glazing Size: 1060 75
Customsteel hollowcore
bracket, insulated
225mmwood fibre insulation
Triple glazing in 50x30mm
steel bracket, glued
38x50mmvertical treated
timber battens at 400 crs
Curved precast concrete
units with steel diaphragm
38x50mmhorizontal
counterbattens at 400 crs
Preformed stainless steel
cavity drain plate
20mmcharred accoya
timber cladding
38mmrigid insulation board
Vertical timber cladding in
background
Triple glazing in 50x30mm
steel l-bracket with bottom
of glass blacked out
Insulated stainless steel sill
Vapour barrier
20mmcharred accoya
timber cladding
38x50mmtimber
counterbattens
38x50mmvertical treated
timber battens
Curved precast concrete
wall unit with 225mmwood
fibre insulation
Precast concrete sill integral
with wall unit
Community Medical Centre
Construction Details
Eric Stilwell
As Shown
26.10.2009
Y4-01-MEDICAL-010 1
Allan Read, Dan O'Sullivan
Corner Detail: H7-010
Scale 1:10
Corner Detail: H6-010
Scale 1:10
Window J amb Detail: H8-010
Scale 1:5
Window Sill Detail: V11-010
Scale 1:5
Window Head Detail: V10-010
Scale 1:5
1. USE FIGURED DIMENSIONS ONLY -
DO NOT SCALE
2. ALL DRAWINGS TO BE READ IN
CONJ UNCTION WITH THE
SPECIFICATION
3. CODE 4 LEAD:-
(1.8mmTHICK, 20.41 kg/m|)
- FOR USE ON FLAT/PITCHED ROOFING
REQUIRES:-
- PATTINATION TREATMENT - AN
APPLICATION OF OIL TO AVOID
UNSIGHTLY RESIDUE BUILDING UP ON
THE SURFACE
- CLIPS
- NAILS
- WOOD CORE ROLL
- GEOTEC UNDERLAY
4. CODE 4 LEAD (AS ABOVE)
- FOR USE ON HIP/RIDGE FLASHINGS
REQUIRES:-
- PATTINATION TREATMENT - AN
APPLICATION OF OIL TO AVOID
UNSIGHTLY RESIDUE BUILDING UP ON
THE SURFACE
- CLIPS
- WOOD CORE ROLL
5. CODE 6 LEAD
(2.65mmTHICK, 30.05 kg/m|)
- FOR USE IN PARAPET BOX GUTTERS
REQUIRES:-
- PATTINATION TREATMENT - AN
APPLICATION OF OIL TO AVOID
UNSIGHTLY RESIDUE BUILDING UP ON
THE SURFACE
- CLIPS
- NAILS
- EXPANSION J OINT
6. CODE 4 LEAD (AS ABOVE)
- FOR USE AS VERTICAL CLADDING
REQUIRES:-
- PATTINATION TREATMENT - AN
APPLICATION OF OIL TO AVOID
UNSIGHTLY RESIDUE BUILDING UP ON
THE SURFACE
- CLIPS
- NAILS
- DOME HEAD SCREWS

Das könnte Ihnen auch gefallen