Beruflich Dokumente
Kultur Dokumente
e
m
o
v
e
r
s
i
o
n
1
[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FNE Ltd. 2009 | www.finesoftware.eu]
CantiIever waII anaIysis
Input data
Project
Date : 26/10/2012
MateriaI of structure
Unit weight = 23.00 kN/m
3
Analysis of concrete structures carried out according to the standard EN 1992 1-1 (EC2).
Concrete : C 20/25
Longitudinal steel : B500
Geometry of structure
No.
Coordinate
X [m]
Depth
Z [m]
1
2
3
4
5
6
7
8
9
10
11
0.00
0.00
3.00
3.00
3.00
2.50
2.50
-2.10
-2.10
-0.60
-0.20
0.00
5.00
5.00
5.60
5.80
5.80
5.60
5.60
5.00
5.00
0.00
The origin [0,0] is located at the most upper right point of the wall.
Wall section area = 5.16 m
2
.
Basic soiI parameters
No. Name Pattern
ef
[]
c
ef
[kPa]
[kN/m
3
]
su
[kN/m
3
]
[]
1 Ci 24.00 18.00 1.00 20.00 2.00
All soils are considered as cohesionless for at rest pressure analysis.
SoiI parameters
Ci
Unit weight :
Stress-state :
Angle of internal friction :
Cohesion of soil :
Angle of friction struc.-soil :
Soil :
Saturated unit weight :
effective
ef
c
ef
cohesionless
sat
=
=
=
=
=
1.00
24.00
18.00
2.00
30.00
kN/m
3
kPa
kN/m
3
GeoIogicaI profiIe and assigned soiIs
d
e
m
o
v
e
r
s
i
o
n
d
e
m
o
v
e
r
s
i
o
n
2
[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FNE Ltd. 2009 | www.finesoftware.eu]
No.
Layer
[m]
Assigned soiI Pattern
1
2
3
5.60
0.40
-
Ci
Ci
Ci
Terrain profiIe
Terrain behind the structure is flat.
Water infIuence
GWT behind the structure lies at a depth of 4.20 m
Uplift in foot. bottom due to different pressures is considered as linear.
Inserted surface Ioads
No.
Surcharge
new change
Type Name
Mag.1
[kN/m
2
]
Mag.2
[kN/m
2
]
Ord.x
x [m]
Length
I [m]
Depth
z [m]
1 YES Surface agua 10.00 on terrain
Resistance on front face of the structure
Resistance on front face of the structure is not considered.
AppIied forces acting on the structure
No.
Force
new change
Name
Fx
[kN/m]
Fz
[kN/m]
M
[kNm/m]
x
[m]
z
[m]
1 YES Force No. 1 2.50 5.50 15.00 2.00 3.00
AnaIysis settings
Active earth pressure calculation - Coulomb (CSN 730037)
Passive earth pressure calculation - Caqout-Kerisel (CSN 730037)
Standard for concrete structures - EN 1992 1-1 (EC2)
Analysis carried out according to classical theory (safety factor)
Safety factor for slip
Safety factor for overturning
Factor of safety for bearing capacity
=
=
=
1.50
1.50
1.50
The wall is free to move. Active earth pressure is therefore assumed.
Verification No. 1
Forces acting on construction
Name F
hor
[kN/m]
App.Pt.
Z [m]
F
vert
[kN/m]
App.Pt.
X [m]
Design
coefficient
Weight - wall
Weight - earth wedge
Active pressure
Water pressure
Uplift pressure
agua
0.00
0.00
0.00
12.80
0.00
0.82
-1.22
-1.15
-5.60
-0.33
0.00
-0.75
118.68
48.58
0.00
0.00
-8.00
30.17
2.34
3.42
2.10
2.10
3.40
3.60
1.000
1.000
1.000
1.000
1.000
1.000
d
e
m
o
v
e
r
s
i
o
n
d
e
m
o
v
e
r
s
i
o
n
3
[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FNE Ltd. 2009 | www.finesoftware.eu]
Name F
hor
[kN/m]
App.Pt.
Z [m]
F
vert
[kN/m]
App.Pt.
X [m]
Design
coefficient
Force No. 1 -2.50 -2.60 5.50 4.10 1.000
Verification of compIete waII
Check for overturning stabiIity
Resisting moment
Overturning moment
M
res
M
ovr
=
=
547.49
-16.62
kNm/m
kNm/m
Safety factor = 1000.00 > 1.50
WaII for overturning is SATISFACTORY
Check for sIip
Resisting horizontal force
Active horizontal force
H
res
H
act
=
=
178.79
3.48
kN/m
kN/m
Safety factor = 51.45 > 1.50
WaII for sIip is SATISFACTORY
Forces acting at the centre of footing bottom
Overall moment
Normal force
Shear force
M
N
Q
=
=
=
-66.31
195.22
3.46
kNm/m
kN/m
kN/m
OveraII check - WALL is SATISFACTORY
Bearing capacity of foundation soiI
Forces acting at the centre of the footing bottom
Number
Moment
[kNm/m]
Norm. force
[kN/m]
Shear Force
[kN/m]
Eccentricity
[m]
Stress
[kPa]
1 -66.31 195.22 3.46 0.00 38.25
Spread footing verification
Input data
Basic soiI parameters
No. Name Pattern
ef
[]
c
ef
[kPa]
[kN/m
3
]
su
[kN/m
3
]
[]
1 Ci 24.00 18.00 1.00 20.00 2.00
All soils are considered as cohesionless for at rest pressure analysis.
SoiI parameters
Ci
Unit weight :
Angle of internal friction :
Cohesion of soil :
Oedometric modulus :
Saturated unit weight :
ef
c
ef
E
oed
sat
=
=
=
=
=
1.00
24.00
18.00
30.00
kN/m
3
kPa
MPa
kN/m
3
d
e
m
o
v
e
r
s
i
o
n
d
e
m
o
v
e
r
s
i
o
n
4
[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FNE Ltd. 2009 | www.finesoftware.eu]
Foundation
Foundation type: strip footing
Depth from ground surface
Depth of footing bottom
Foundation thickness
ncl. of finished grade
ncl. of footing bottom
h
z
d
t
s
1
s
2
=
=
=
=
=
5.80
0.00
0.60
0.00
2.25
m
m
m
ef
c
ef
sat
=
=
=
=
1.00
24.00
18.00
30.00
kN/m
3
kPa
kN/m
3
Rigid bodies
Number Name SampIe
[kN/m
3
]
1 Rigid body 23.00
Assigning and surfaces
Number Surface position
Coordinates of surface points [m]
x z x z
Assigned
soiI
1
2
3
4
5
0.00
3.00
17.40
3.00
0.00
-0.20
-2.10
2.50
3.00
3.00
17.40
0.00
17.40
2.50
-2.10
-14.50
0.00
-14.50
17.40
-5.30
-5.90
-0.30
-5.90
-5.30
-0.30
-5.30
-5.90
-6.10
-6.10
-5.90
-6.30
-6.10
-6.10
-5.90
-6.30
-6.30
-11.30
-6.30
3.00
17.40
0.00
3.00
0.00
-0.60
-2.10
2.50
17.40
3.00
17.40
3.00
2.50
-14.50
-14.50
17.40
-5.30
-5.90
-0.30
-5.30
-0.30
-5.30
-5.90
-6.10
-6.10
-5.90
-6.30
-6.10
-5.90
-5.90
-6.30
-11.30
Ci
Rigid body
Ci
Ci
Ci
Surcharge
d
e
m
o
v
e
r
s
i
o
n
d
e
m
o
v
e
r
s
i
o
n
8
[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FNE Ltd. 2009 | www.finesoftware.eu]
Number Type
/
z [m] / x
1
[m]
/
x [m] / z
1
[m]
/
I [m] / x
2
[m]
/
b [m] / z
2
[m]
SIope
[]
Magnitude
q, q
1
, f, F q
2 unit
1 strip on terrain x = 0.00 l = 17.40 0.00 10.00 kN/m
2
Surcharges
Number Name
1 agua
Water
Water type : GWT
Number GWT Iocation
Coordinates of GWT points [m]
x z x z x z
1
-14.50
17.40
-6.10
-4.50
0.00 -6.10 0.05 -4.50
TensiIe crack
Tensile crack not inputted.
Earthquake
Earthquake not included.
AnaIysis settings
Analysis settings :
Analysis type :
Safety factor :
Standard
Safety factor
1.50
ResuIts (Stage of construction 1)
AnaIysis 1
CircuIar sIip surface
Slip surface is not specified
SIope stabiIity verification (Bishop)
AnaIysis was not performed.