DEMONSTRATION LIMITS Automatic takeoff list of parts from ducts drawn with Manual D Ductsize or entered with Tabular Manual D Ductsize is limited to the first 6 trunks and first 6 runouts. 8 duct parts

Bill of Materials

10 fitting parts 6 register or diffuser parts 6 non-ductwork parts

Two Zones 10 foot wall heights Chvac 35 foot wall lengths 15 people per zone

Ductsize

6 trunks and 6 runouts

Drawing Board

Drawing Board is limited in calculation by the program it is linked with, not by the size of the drawings. A demo version of Drawing Board in RHVAC will only calculate for 3 rooms. In DUCTSIZE, a demo version of Drawing Board will only calculate for 6 trunks and 6 runout ducts..

D-Pipe

Allows up to 20 pipe sections

ECA

Allows heating and cooling loads up to 17,000 Btuh

One drawing per project E-Coord Maximum of two devices per drawing

Wire Sizing Conduit Sizing Voltage Drop Short Circuit Room Lighting Electrical Tools Service Entrance Panel Sizing Motor Equipment Sizing Power & Current Calculator Ohm's Law Calculator Power Factor Correction Capacitor Sizing

The maximum circuit voltage is 400 volts. The maximum conductor ampacity is 15 amps. The maximum motor kVA is 10 kVA. The maximum motor horsepower is 10 hp. The maximum number of conductor types in a conduit is one. The maximum number of components in a network is one. The maximum number of circuit loads in a network is one. The maximum number of components in a network is one. The maximum number of motors or generators in a network is one. The maximum room size is 12 feet by 12 feet. The maximum number of circuits is one. The maximum motor voltage is 115 volts. The maximum circuit voltage is 400 volts. The maximum conductor ampacity is 15 amps. The maximum motor kVA is 10 kVA. The maximum motor kilowatts is 10 kW. The maximum motor horsepower is 10 hp. The maximum current is 15 amps. The maximum voltage is 400 volts. The maximum resistance is 25 ohms. The maximum motor kilowatts is 10 kW. The maximum motor voltage is 400 volts. The maximum motor current is 15 amps.

General Project Data Total Building Area Design Cooling Load 560 Square Feet 20,000 Btuh

www.elitesoft.com/web/homepage/elite_demonstration_limits.html#chvacw

1/5

7/28/13
Design Heating Load

Elite Software - Demonstration Limits


20,000 Btuh HVAC System Limits Cooling Load Heating Load Appliance Limits Indoor Lighting Outdoor Lighting Appliance Quantity Appliance Usage Gas Appliance Quantity 0.1 Watts/Square Ft. 100 Watts 1 100 KWH/Year 1 100 Therm/Year 1 100 KWH/Person 100 KWH 1 100 KWH/Person 100 KWH Water Heater Limits Water Heater Daily Usage Water Heater Peak Usage Number of Daily Uses Number of Peak Uses Disaggregation Monthly Utility Bill Up to $125 30 Gallons 30 Gallons 1 1 20,000 Btuh 20,000 Btuh

Energy Audit

Gas Appliance Usage Range Quantity Range Usage Misc. Range Electrical Usage Dryer Quantity Dryer Usage Misc. Dryer Electrical Usage

Fire

Allows up to 11 nodes (10 pipe sections)

GasVent

Input limit of 40 MBH

Heavent

The demo version will not save files.

Duct Sizing Wire Sizing Coil Interpolation State Point Psychrometrics Mixed Air Psychrometrics HVAC Tools Fan Curve Analysis Fan Cost Analysis U-Factor Calculation Refrigeration Line Sizing Hydraulic Pipe Sizing Hot/Chilled Water Pipe Sizing Gas Pipe Sizing

The maximum design air allowed is 300 CFM The maximum circuit voltage allowed is 400 volts and the maximum unit ampacity allowed is 15 amp. The maximum outdoor dry bulb temperature allowed is 86 degrees F. The minimum elevation allowed is 15,000 feet and maximum dry bulb temperature allowed is 80 deg F. The minimum elevation allowed is 15,000 feet and maximum dry bulb temperature allowed is 80 deg F. The maximum rated and specified air allowed is 1,000 CFM. The brake horsepower allowed is 2 and the CFM allowed is 1,000 CFM The maximum number of different materials allowed per cross section is 4 (not counting the framing percentage). The system capacity allowed is 5 MBtuh The flowrate allowed is 2 GPM The pipe length is limited to 20 feet The pipe length is limited to 20 feet

www.elitesoft.com/web/homepage/elite_demonstration_limits.html#chvacw

2/5

7/28/13
H-Sym

Elite Software - Demonstration Limits


This program is limited to less than twenty sections in your system

The paste function into other programs such as AutoCAD and Word has been disabled. Projects may only be saved under a single project name. HVAC Solution Equipment schedules are limited to a single line per schedule. The tools menu is disabled. The phrase "HVAC Solution Demo" is printed out across each schematic.

Maximum room width is 12 feet (4 meters) InPoint Maximum room length is 12 feet (4 meters)

Life

Allows entry of costs up to $5,000.00

Limited to 3 rooms Light Limited to room size of 12 x 12

Manual D Ductsize

Maximum of 6 trunks and 6 runouts

The maximum grid is limited to at most 20 rows and 20 columns OutPoint The maximum number of luminaires is 3

Maximum of 6 network devices Motor Capacitor bank General purpose load General purpose panel Motor control center Switchboard

Panel

One of each of the following:

Proposal Maker

The document cannot be printed The document cannot be exported (to a doc, rtf, pdf or html file)

Elevation from 9,000 to 11,000 feet PsyChart Dry Bulb temperature from 35 to 100 degrees F 13 points and processes per chart

Quote

Restricted to a selling price of $500 per model quoted plus an additional $500 for associated material, labor and tax

Wall heights up to 10 feet Wall lengths up to 15 feet Roof lengths up to 15 feet Refrig Roof widths up to 15 feet Pounds per unit up to 50 lbs Units per period up to 5 Holding units up to 50 lbs

Three rooms 15' wall lengths

www.elitesoft.com/web/homepage/elite_demonstration_limits.html#chvacw

3/5

7/28/13
Rhvac

Elite Software - Demonstration Limits


8' wall heights Six trunks & six runouts on Tabular Manual D Ductsize window

Shadow

Allows two glass types, limited to 2 by 3 feet each

Maximum of 6 network devices Motor Capacitor bank General purpose load General purpose panel Motor control center Switchboard

Short

One of each of the following:

S-Pipe

Limited to 20 pipe sections

Maximum of 6 network devices Motor Capacitor bank General purpose load General purpose panel Motor control center Switchboard

V-Drop

One of each of the following:

The number of hoods in your system must be no more than two Vent The CFM value for each hood is restricted to 1800

www.elitesoft.com/web/homepage/elite_demonstration_limits.html#chvacw

4/5

7/28/13

Elite Software - Demonstration Limits