Sie sind auf Seite 1von 390

Node

Horizontal Vertical
Horizontal Moment
L/C
Fx kN
Fy kN
Fz kN
Mx kNm My kNm Mz kNm
1001 50 1.0(DL+50%LL+EQUP) 11.876 644.043
15.81
15.23
0.156
-3.454
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
139.547 885.261
49.764 103.619
28.087
370.37
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-115.795 402.826
-18.144
-73.158
-27.776 -377.277
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
140 831.275
49.771 102.506
28.1 369.577
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-115.342
348.84
-18.137
-74.272
-27.764 -378.071
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
52.888 860.852 111.184 262.625
16.824 116.156
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-29.135 427.234
-79.564 -232.164
-16.513 -123.063
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
53.341 806.867 111.191 261.512
16.837 115.362
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-28.682 373.249
-79.558 -233.277
-16.501 -123.857
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
51.348 750.782
45.917
93.385
10.589
111.94
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-27.595 537.305
-14.297
-62.924
-10.278 -118.847
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
51.801 696.796
45.924
92.272
10.602 111.146
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-27.142 483.319
-14.29
-64.037
-10.266 -119.641
63 1.0(DL+ EQUP +WIND X) 6.634 584.919
15.96
14.509
-0.326
10.735
64 1.0(DL+ EQUP -WIND X) 18.025 595.196
15.674
13.726
0.662
-19.23
65 1.0(DL+ EQUP+LL +WIND X)
5.728
692.89
15.947
16.735
-0.351
12.322
66 1.0(DL+ EQUP+LL -WIND 17.119
X)
703.168
15.661
15.952
0.637
-17.642
67 1.0(DL+ EQUP +WIND Z) 12.323 599.523
21.137
27.767
-0.164
-4.214
68 1.0(DL+ EQUP -WIND Z) 12.336 580.592
10.497
0.468
0.5
-4.281
69 1.0(DL+ EQUP+LL +WIND11.417
Z)
707.494
21.124
29.993
-0.189
-2.627
70 1.0(DL+ EQUP+LL -WIND Z)
11.43 688.564
10.484
2.694
0.475
-2.693
1002 50 1.0(DL+50%LL+EQUP) -11.286 834.272
13.294
15.628
-0.14
14.425
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
192.618 1250.291
51.101 114.678
11.313
444.78
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-215.191 418.254
-24.512
-83.423
-11.593 -415.929
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
192.63 1170.203
52.164 113.377
11.3 443.963
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-215.179 338.166
-23.449
-84.725
-11.606 -416.746
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
54.119 1127.364 127.539 316.515
11.855 152.173
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-76.692 541.181 -100.951 -285.259
-12.136 -123.323
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
54.131 1047.276 128.603 315.213
11.842 151.357
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-76.68 461.093
-99.887 -286.561
-12.148 -124.139
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
51.721 999.945
48.753 108.871
5.404 147.286
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-74.294
668.6
-22.165
-77.615
-5.684 -118.435
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
51.733 919.857
49.817 107.569
5.391 146.469
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-74.282 588.512
-21.101
-78.917
-5.697 -119.252
63 1.0(DL+ EQUP +WIND X)-18.983 743.839
14.299
14.16
-0.249
28.971
64 1.0(DL+ EQUP -WIND X) -3.566
764.53
14.417
14.492
-0.057
-1.754
65 1.0(DL+ EQUP+LL +WIND-19.007
X)
904.015
12.171
16.764
-0.224
30.605
66 1.0(DL+ EQUP+LL -WIND X)-3.59 924.706
12.29
17.095
-0.032
-0.12
67 1.0(DL+ EQUP +WIND Z)-11.302 764.584
20.983
31.065
-0.154
13.661
68 1.0(DL+ EQUP -WIND Z) -11.247 743.785
7.733
-2.413
-0.152
13.556
69 1.0(DL+ EQUP+LL +WIND-11.326
Z)
924.76
18.856
33.668
-0.129
15.295
70 1.0(DL+ EQUP+LL -WIND-11.271
Z)
903.961
5.606
0.19
-0.127
15.189
1003 50 1.0(DL+50%LL+EQUP)
-0.718
794.75
-1.354
3.436
0.105
6.685
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
217.364 1031.705
38.048 103.854
11.651 447.869
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-218.8 557.794
-40.755
-96.983
-11.442 -434.498
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
217.819 959.082
39.093 103.028
11.588 446.695
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-218.345 485.171
-39.71
-97.808
-11.505 -435.673
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
69.267 1016.754 119.987 313.206
14.706 147.976
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-70.704 572.746 -122.694 -306.334
-14.496 -134.606
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
69.722
944.13 121.032
312.38
14.642 146.802

58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-70.248 500.122 -121.649
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
66.681 909.395
36.251
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-68.118 680.105
-38.958
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
67.137 836.771
37.296
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-67.663 607.481
-37.913
63 1.0(DL+ EQUP +WIND X) -7.965 727.335
-0.412
64 1.0(DL+ EQUP -WIND X) 7.439 716.917
-0.205
65 1.0(DL+ EQUP+LL +WIND -8.875
X)
872.583
-2.503
66 1.0(DL+ EQUP+LL -WIND X)
6.528 862.164
-2.295
67 1.0(DL+ EQUP +WIND Z) -0.298 730.552
6.438
68 1.0(DL+ EQUP -WIND Z) -0.228
713.7
-7.055
69 1.0(DL+ EQUP+LL +WIND -1.209
Z)
875.799
4.348
70 1.0(DL+ EQUP+LL -WIND Z)
-1.138 858.948
-9.146
1004 50 1.0(DL+50%LL+EQUP)
-2.373
896.36
-1.993
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
213.145 961.392
47.756
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-217.89 831.328
-51.741
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
213.44 878.668
48.599
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-217.595 748.604
-50.898
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
66.839 1078.469 149.754
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-71.584 714.252 -153.739
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
67.135 995.745 150.597
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-71.289 631.528 -152.896
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
64.278 964.493
45.294
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-69.023 828.228
-49.28
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
64.573 881.769
46.137
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-68.728 745.504
-48.437
63 1.0(DL+ EQUP +WIND X) -9.304 813.569
-1.211
64 1.0(DL+ EQUP -WIND X)
5.15 813.704
-1.088
65 1.0(DL+ EQUP+LL +WIND -9.895
X)
979.016
-2.897
66 1.0(DL+ EQUP+LL -WIND X)
4.559 979.152
-2.774
67 1.0(DL+ EQUP +WIND Z) -2.09 821.818
6.684
68 1.0(DL+ EQUP -WIND Z) -2.064 805.455
-8.983
69 1.0(DL+ EQUP+LL +WIND -2.681
Z)
987.265
4.998
70 1.0(DL+ EQUP+LL -WIND Z)
-2.655 970.903
-10.669
1005 50 1.0(DL+50%LL+EQUP)
5.141 1097.083
-2.763
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
204.062 1362.306
68.467
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-193.78 831.859
-73.993
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
204.353
1261.1
69.494
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-193.489 730.654
-72.965
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
69.124 1419.299 208.869
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-58.843 774.866 -214.396
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
69.416 1318.093 209.897
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-58.551 673.661 -213.368
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
66.733 1251.248
63.761
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-56.452 942.917
-69.288
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
67.025 1150.042
64.789
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-56.16 841.712
-68.26
63 1.0(DL+ EQUP +WIND X) -0.994 1000.999
-1.746
64 1.0(DL+ EQUP -WIND X) 11.859 990.755
-1.725
65 1.0(DL+ EQUP+LL +WIND -1.577
X)
1203.411
-3.802
66 1.0(DL+ EQUP+LL -WIND 11.275
X)
1193.166
-3.781
67 1.0(DL+ EQUP +WIND Z) 5.425 1007.337
8.243

-307.16
99.31
-92.439
98.485
-93.265
2.357
2.863
4.009
4.514
19.041
-13.821
20.692
-12.17
4.334
139.955
-131.287
138.419
-132.823
418.436
-409.768
416.9
-411.304
133.282
-124.613
131.745
-126.15
2.63
2.965
5.703
6.039
22.996
-17.401
26.07
-14.327
2.042
182.497
-178.412
181.346
-179.562
539.497
-535.413
538.347
-536.563
170.734
-166.649
169.583
-167.799
0.859
0.925
3.159
3.225
25.329

-14.56
6.289
-6.08
6.226
-6.143
-0.1
0.183
0.027
0.31
0.241
-0.158
0.368
-0.031
0.547
15.922
-14.828
15.865
-14.885
23.718
-22.624
23.661
-22.682
9.568
-8.474
9.511
-8.532
0.277
0.702
0.392
0.818
0.363
0.616
0.478
0.732
0.079
34.651
-34.492
34.653
-34.49
26.415
-26.257
26.417
-26.255
14.35
-14.191
14.352
-14.19
-0.407
0.57
-0.411
0.566
-0.14

-135.78
142.914
-129.543
141.739
-130.718
20.455
-9.433
22.804
-7.085
5.57
5.452
7.919
7.801
8.032
471.472
-455.409
470.377
-456.504
156.568
-140.505
155.473
-141.6
151.191
-135.127
150.096
-136.223
21.869
-7.996
24.06
-5.805
6.979
6.893
9.171
9.084
1.903
453.553
-449.748
452.543
-450.758
146.837
-143.031
145.827
-144.042
141.515
-137.709
140.505
-138.719
14.921
-13.136
16.941
-11.115
0.931

68 1.0(DL+ EQUP -WIND Z)


5.44 984.417
-11.714
69 1.0(DL+ EQUP+LL +WIND Z)
4.842 1209.748
6.187
70 1.0(DL+ EQUP+LL -WIND Z)
4.856 1186.828
-13.77
1006 50 1.0(DL+50%LL+EQUP)
-0.331 1272.439
-4.127
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
180.292 1389.493
79.396
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-180.954 1155.385
-87.65
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
180.295 1269.278
80.671
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-180.951 1035.17
-86.375
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
57.917 1618.014
255.89
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-58.579 926.864 -264.145
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
57.92 1497.799 257.165
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-58.576 806.649 -262.869
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
55.757 1404.662
76.792
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-56.419 1140.216
-85.046
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
55.76 1284.447
78.067
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-56.416 1020.001
-83.771
63 1.0(DL+ EQUP +WIND X) -5.941 1152.243
-2.854
64 1.0(DL+ EQUP -WIND X) 5.285 1152.204
-2.851
65 1.0(DL+ EQUP+LL +WIND -5.947
X)
1392.674
-5.404
66 1.0(DL+ EQUP+LL -WIND X)
5.279 1392.634
-5.401
67 1.0(DL+ EQUP +WIND Z) -0.342 1165.079
7.896
68 1.0(DL+ EQUP -WIND Z) -0.314 1139.369
-13.601
69 1.0(DL+ EQUP+LL +WIND -0.348
Z)
1405.509
5.346
70 1.0(DL+ EQUP+LL -WIND Z)-0.32 1379.799
-16.151
1007 50 1.0(DL+50%LL+EQUP)
0.943 1239.795
-3.804
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
175.973 1363.522
73.153
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-174.088 1116.068
-80.761
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
175.864 1246.244
74.823
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-174.197 998.791
-79.091
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
57.522 1577.644 230.197
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-55.636 901.946 -237.805
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
57.412 1460.367 231.867
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-55.746 784.668 -236.135
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
55.517 1371.071
69.23
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-53.631 1108.519
-76.838
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
55.407 1253.794
70.9
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-53.741 991.241
-75.168
63 1.0(DL+ EQUP +WIND X) -4.437 1122.17
-2.129
64 1.0(DL+ EQUP -WIND X) 6.104 1122.865
-2.138
65 1.0(DL+ EQUP+LL +WIND -4.218
X)
1356.725
-5.47
66 1.0(DL+ EQUP+LL -WIND X)
6.322 1357.42
-5.479
67 1.0(DL+ EQUP +WIND Z) 0.818 1135.183
7.744
68 1.0(DL+ EQUP -WIND Z) 0.849 1109.852
-12.011
69 1.0(DL+ EQUP+LL +WIND Z)
1.037 1369.738
4.403
70 1.0(DL+ EQUP+LL -WIND Z)
1.067 1344.407
-15.352
1008 50 1.0(DL+50%LL+EQUP) -15.246 988.554
14.848
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
111.057 1325.671
66.469
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-141.549 651.438
-36.774
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
111.278
1238.9
66.567
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-141.328 564.667
-36.676
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
25.582 1303.711 156.748
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-56.074 673.398 -127.053

-23.545
27.629
-21.245
2.006
215.671
-211.66
214.384
-212.947
667.62
-663.608
666.333
-664.895
208.924
-204.913
207.638
-206.2
0.715
0.722
3.289
3.296
27.237
-25.799
29.811
-23.225
1.95
184.742
-180.841
184.351
-181.231
558.392
-554.492
558.002
-554.882
175.275
-171.375
174.885
-171.765
1.571
1.548
2.352
2.329
24.263
-21.143
25.043
-20.363
17.992
151.123
-115.139
149.9
-116.361
386.13
-350.146

0.303
-0.144
0.299
-0.27
34.457
-34.998
34.491
-34.963
21.206
-21.746
21.24
-21.712
12.971
-13.512
13.006
-13.477
-0.781
0.309
-0.85
0.24
-0.35
-0.121
-0.42
-0.191
-0.14
29.337
-29.618
29.322
-29.633
17.618
-17.899
17.603
-17.914
11.003
-11.284
10.988
-11.299
-0.629
0.319
-0.599
0.349
-0.045
-0.266
-0.015
-0.235
-0.316
20.039
-20.671
20.038
-20.673
22.539
-23.171

0.854
2.951
2.875
5.123
443.562
-433.317
442.866
-434.014
146.11
-135.864
145.413
-136.561
140.864
-130.619
140.167
-131.315
17.532
-8.68
18.926
-7.287
4.472
4.38
5.865
5.774
2.585
413.088
-407.917
412.715
-408.29
134.873
-129.703
134.501
-130.075
130.006
-124.836
129.634
-125.209
14.185
-9.759
14.93
-9.014
2.259
2.166
3.004
2.911
12.615
387.217
-361.987
386.887
-362.317
133.445
-108.215

57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
25.803 1216.94 156.846
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-55.853 586.627 -126.955
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
23.96 1149.667
60.31
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-54.452 827.442
-30.614
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
24.181 1062.896
60.407
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-54.232
740.67
-30.516
63 1.0(DL+ EQUP +WIND X)-18.839 907.863
14.992
64 1.0(DL+ EQUP -WIND X) -11.211 895.703
14.899
65 1.0(DL+ EQUP+LL +WIND-19.281
X)
1081.406
14.797
66 1.0(DL+ EQUP+LL -WIND-11.653
X)
1069.245
14.703
67 1.0(DL+ EQUP +WIND Z)-15.043
912.08
21.963
68 1.0(DL+ EQUP -WIND Z) -15.007 891.487
7.929
69 1.0(DL+ EQUP+LL +WIND-15.485
Z)
1085.622
21.767
70 1.0(DL+ EQUP+LL -WIND-15.449
Z)
1065.029
7.733
1009 50 1.0(DL+50%LL+EQUP)
2.558 922.534
3.343
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
166.907 1222.601
64.306
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-161.79 622.467
-57.62
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
167.984 1110.819
62.869
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-160.714 510.685
-59.057
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
54.861 1017.997 173.927
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-49.744 827.072
-167.24
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
55.938 906.215
172.49
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-48.667 715.289 -168.677
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
53.44 1014.71
57.241
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-48.324 830.359
-50.554
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
54.517 902.928
55.804
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-47.247 718.576
-51.992
63 1.0(DL+ EQUP +WIND X) -5.011 801.726
2.178
64 1.0(DL+ EQUP -WIND X) 12.282 819.779
1.634
65 1.0(DL+ EQUP+LL +WIND -7.165
X)
1025.29
5.053
66 1.0(DL+ EQUP+LL -WIND 10.128
X)
1043.343
4.508
67 1.0(DL+ EQUP +WIND Z) 3.648 810.572
11.52
68 1.0(DL+ EQUP -WIND Z) 3.622 810.932
-7.708
69 1.0(DL+ EQUP+LL +WIND Z)
1.494 1034.137
14.394
70 1.0(DL+ EQUP+LL -WIND Z)
1.469 1034.497
-4.833
1010 50 1.0(DL+50%LL+EQUP)
1.563 1167.054
6.698
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
261.833 1481.578
73.983
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-258.707
852.53
-60.587
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
259.916 1310.406
70.839
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-260.625 681.358
-63.73
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
84.319 1266.744
210.33
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-81.192 1067.364 -196.934
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
82.401 1095.572 207.186
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-83.11 896.192 -200.078
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
82.095 1264.017
69.868
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-78.968 1070.09
-56.472
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
80.177 1092.846
66.724
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-80.886 898.918
-59.615
63 1.0(DL+ EQUP +WIND X)-12.211 986.414
3.446
64 1.0(DL+ EQUP -WIND X) 11.502 1005.35
3.663
65 1.0(DL+ EQUP+LL +WIND -8.376
X)
1328.757
9.733
66 1.0(DL+ EQUP+LL -WIND 15.337
X)
1347.694
9.95

384.908
-351.368
135.391
-99.407
134.169
-100.629
16.878
16.661
19.323
19.106
34.141
-0.602
36.586
1.843
5.486
155.843
-144.871
153.687
-147.027
425.131
-414.16
422.976
-416.315
138.15
-127.179
135.995
-129.334
4.016
2.644
8.327
6.955
26.688
-20.027
30.998
-15.716
7.293
174.913
-160.327
171.269
-163.97
516.687
-502.101
513.044
-505.745
165.129
-150.542
161.485
-154.186
3.37
3.929
10.657
11.216

22.538
-23.173
9.84
-10.472
9.838
-10.474
-0.636
0.001
-0.633
0.004
0.035
-0.67
0.038
-0.667
0.471
20.515
-19.574
20.441
-19.649
11.98
-11.039
11.906
-11.114
7.938
-6.997
7.864
-7.072
-0.1
0.892
0.049
1.041
0.137
0.655
0.286
0.804
0.147
11.163
-10.869
11.121
-10.91
11.23
-10.935
11.188
-10.977
5.393
-5.098
5.351
-5.14
-0.049
0.26
0.035
0.344

133.115
-108.545
128.971
-103.74
128.64
-104.07
23.104
1.466
23.765
2.127
12.333
12.237
12.994
12.898
-5.897
411.704
-423.499
411.975
-423.228
126.924
-138.719
127.195
-138.448
123.397
-135.192
123.669
-134.921
15.062
-26.315
14.52
-26.857
-5.658
-5.594
-6.201
-6.137
-1.992
498.818
-502.803
500.214
-501.408
157.162
-161.147
158.557
-159.751
152.916
-156.9
154.311
-155.505
20.714
-21.908
17.924
-24.698

67 1.0(DL+ EQUP +WIND Z) -0.337 995.834


15.464
68 1.0(DL+ EQUP -WIND Z) -0.371
995.93
-8.355
69 1.0(DL+ EQUP+LL +WIND Z)
3.498 1338.178
21.751
70 1.0(DL+ EQUP+LL -WIND Z)
3.464 1338.273
-2.068
1011 50 1.0(DL+50%LL+EQUP)
1.457 727.224
6.766
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
264.386 1025.503
72.374
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-261.472 428.945
-58.843
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
264.596 909.378
69.678
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-261.263
312.82
-61.539
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
85.139 822.452 209.147
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-82.226 631.997 -195.615
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
85.349 706.326 206.451
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-82.016 515.872 -198.311
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
82.943 819.246
69.493
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-80.029 635.202
-55.961
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
83.152 703.121
66.797
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-79.819 519.077
-58.657
63 1.0(DL+ EQUP +WIND X) -9.508 619.318
3.905
64 1.0(DL+ EQUP -WIND X) 12.841
602.88
4.234
65 1.0(DL+ EQUP+LL +WIND -9.928
X)
851.568
9.297
66 1.0(DL+ EQUP+LL -WIND 12.422
X)
835.131
9.627
67 1.0(DL+ EQUP +WIND Z) 1.689 611.173
15.483
68 1.0(DL+ EQUP -WIND Z) 1.644 611.024
-7.344
69 1.0(DL+ EQUP+LL +WIND Z)1.27 843.424
20.876
70 1.0(DL+ EQUP+LL -WIND Z)
1.224 843.275
-1.952
1012 50 1.0(DL+50%LL+EQUP)
3.356 776.575
7.408
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
268.192 794.961
79.765
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-261.48 758.189
-64.949
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
267.663 662.444
76.782
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-262.009 625.672
-67.931
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
87.508 789.275 228.549
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-80.795 763.875 -213.733
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
86.978 656.758 225.567
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-81.325 631.358 -216.715
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
85.274 784.738
76.363
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-78.561 768.412
-61.547
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
84.744 652.221
73.381
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-79.091 635.895
-64.529
63 1.0(DL+ EQUP +WIND X) -7.293 643.947
4.343
64 1.0(DL+ EQUP -WIND X) 12.947
644.17
4.509
65 1.0(DL+ EQUP+LL +WIND -6.234
X)
908.98
10.307
66 1.0(DL+ EQUP+LL -WIND 14.006
X)
909.203
10.473
67 1.0(DL+ EQUP +WIND Z) 2.843
643.94
16.072
68 1.0(DL+ EQUP -WIND Z) 2.811 644.176
-7.221
69 1.0(DL+ EQUP+LL +WIND Z)
3.902 908.974
22.037
70 1.0(DL+ EQUP+LL -WIND Z)3.87 909.209
-1.256
1013 50 1.0(DL+50%LL+EQUP)
4.031 972.701
6.938
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
251.908 1119.235 108.595
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-243.845 826.167
-94.719
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
251.777 950.801 105.518
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-243.977 657.733
-97.796
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
82.789 1032.801 308.971

32.347
-25.048
39.634
-17.761
6.19
174.295
-161.914
171.376
-164.833
524.068
-511.687
521.149
-514.606
166.579
-154.199
163.661
-157.117
2.843
3.7
8.68
9.537
31.085
-24.541
36.921
-18.704
5.932
190.555
-178.69
187.442
-181.803
570.893
-559.028
567.779
-562.141
181.846
-169.982
178.733
-173.095
2.601
3.037
8.828
9.264
30.872
-25.233
37.098
-19.007
3.339
248.821
-242.142
246.013
-244.95
734.022

0.123
0.087
0.207
0.171
0.158
10.505
-10.19
10.459
-10.236
14.166
-13.85
14.12
-13.897
5.935
-5.62
5.889
-5.666
-0.012
0.235
0.08
0.327
0.285
-0.062
0.378
0.03
0.363
13.391
-12.665
13.336
-12.72
19.501
-18.774
19.445
-18.829
7.97
-7.244
7.915
-7.299
0.167
0.449
0.278
0.559
0.148
0.468
0.258
0.579
0.313
17.521
-16.896
17.464
-16.952
18.816

-0.627
-0.567
-3.417
-3.357
-1.547
509.521
-512.614
509.281
-512.854
160.869
-163.962
160.629
-164.202
156.553
-159.647
156.313
-159.887
18.443
-22.017
18.924
-21.537
-1.818
-1.756
-1.337
-1.276
-3.263
515.22
-521.745
515.543
-521.422
161.388
-167.913
161.711
-167.59
156.978
-163.504
157.302
-163.181
15.922
-21.801
15.276
-22.448
-2.963
-2.916
-3.61
-3.562
-4.566
504.485
-513.617
504.617
-513.485
157.074

56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-74.727 912.602 -295.096 -727.343
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
82.658 864.366 305.895 731.214
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-74.858 744.168 -298.172 -730.151
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
80.705 1022.761 101.927 232.845
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-72.643 922.642
-88.051 -226.166
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
80.574 854.327
98.85 230.037
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-72.774 754.207
-91.128 -228.974
63 1.0(DL+ EQUP +WIND X) -5.066 808.865
3.845
0.483
64 1.0(DL+ EQUP -WIND X) 12.866 799.669
3.878
0.58
65 1.0(DL+ EQUP+LL +WIND -4.803
X)
1145.734
9.998
6.099
66 1.0(DL+ EQUP+LL -WIND 13.128
X)
1136.538
10.03
6.196
67 1.0(DL+ EQUP +WIND Z) 3.916 803.768
18.425
34.286
68 1.0(DL+ EQUP -WIND Z) 3.884 804.765
-10.702
-33.223
69 1.0(DL+ EQUP+LL +WIND Z)
4.179 1140.637
24.577
39.902
70 1.0(DL+ EQUP+LL -WIND Z)
4.146 1141.634
-4.549
-27.607
1014 50 1.0(DL+50%LL+EQUP)
7.192 1156.619
10.251
5.541
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
289.234 1180.411 139.092 333.252
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-274.85 1132.828 -118.591
-322.17
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
288.261 975.871 135.026 329.568
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-275.823 928.289 -122.657 -325.854
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
96.856 1184.194 411.327 1026.33
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-82.472 1129.044 -390.826 -1015.25
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
95.882 979.655 407.261 1022.646
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-83.445 924.505 -394.892 -1018.93
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
94.555 1171.491 135.306 323.178
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-80.172 1141.747 -114.805 -312.096
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
93.582 966.952
131.24 319.494
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-81.145 937.208 -118.871
-315.78
63 1.0(DL+ EQUP +WIND X) -3.533 951.663
6.182
1.853
64 1.0(DL+ EQUP -WIND X) 15.971 952.497
6.186
1.861
65 1.0(DL+ EQUP+LL +WIND -1.587
X)
1360.742
14.315
9.221
66 1.0(DL+ EQUP+LL -WIND 17.917
X)
1361.575
14.319
9.228
67 1.0(DL+ EQUP +WIND Z) 6.244 951.547
23.225
43.218
68 1.0(DL+ EQUP -WIND Z) 6.194 952.613
-10.856
-39.504
69 1.0(DL+ EQUP+LL +WIND Z)8.19 1360.626
31.357
50.585
70 1.0(DL+ EQUP+LL -WIND Z)8.14 1361.692
-2.723
-32.136
1015 50 1.0(DL+50%LL+EQUP) 17.532 1144.712
11.593
8.613
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
274.665 1236.177 150.037 353.729
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-239.602 1053.247
-126.85 -336.503
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
272.006 1035.049 146.185 350.357
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-242.26 852.119 -130.702 -339.875
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
99.707 1182.765 432.936 1059.39
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-64.644 1106.659 -409.749 -1042.16
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
97.049 981.637 429.085 1056.018
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-67.302
905.53 -413.601 -1045.54
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
98.02 1178.589
142.98 336.039
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-62.957 1110.834 -119.793 -318.812
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
95.362 977.461 139.128 332.667
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-65.616 909.706 -123.645 -322.185
63 1.0(DL+ EQUP +WIND X) 5.979 942.256
7.749
5.261
64 1.0(DL+ EQUP -WIND X) 23.768 944.911
7.734
5.221
65 1.0(DL+ EQUP+LL +WIND11.296
X)
1344.513
15.453
12.006

-18.191
18.76
-18.247
8.717
-8.092
8.661
-8.149
0.065
0.447
0.178
0.56
0.057
0.455
0.17
0.568
0.195
21.879
-21.488
21.828
-21.538
18.301
-17.91
18.25
-17.961
9.555
-9.164
9.504
-9.215
-0.106
0.395
-0.005
0.497
0.028
0.261
0.129
0.363
0.054
22.333
-22.224
22.291
-22.265
17.411
-17.302
17.369
-17.343
9.459
-9.35
9.417
-9.391
-0.231
0.257
-0.149

-166.206
157.206
-166.074
152.753
-161.885
152.885
-161.753
13.14
-22.008
12.876
-22.272
-4.459
-4.409
-4.722
-4.673
-9.021
692.79
-710.831
693.674
-709.947
213.833
-231.874
214.717
-230.99
207.97
-226.012
208.855
-225.127
14.848
-31.12
13.078
-32.89
-8.18
-8.093
-9.949
-9.862
-20.753
657.621
-699.127
660.327
-696.422
194.972
-236.479
197.678
-233.773
189.66
-231.167
192.366
-228.461
3.81
-39.905
-1.601

66 1.0(DL+ EQUP+LL -WIND 29.085


X)
1347.168
15.438
67 1.0(DL+ EQUP +WIND Z) 14.913 943.454
26.023
68 1.0(DL+ EQUP -WIND Z) 14.833 943.713
-10.539
69 1.0(DL+ EQUP+LL +WIND Z)
20.23 1345.711
33.726
70 1.0(DL+ EQUP+LL -WIND Z)
20.15 1345.97
-2.836
1016 50 1.0(DL+50%LL+EQUP)
-6.459 1529.531
7.468
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
182.31 1759.495
98.734
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-195.228 1299.568
-83.798
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
183.105 1578.59
96.8
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-194.434 1118.664
-85.733
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
53.403 1619.046 260.213
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-66.322 1440.017 -245.277
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
54.198 1438.141 258.279
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-65.527 1259.112 -247.211
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
51.797 1623.25
88.247
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-64.715 1435.813
-73.311
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
52.591 1442.345
86.313
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-63.92 1254.909
-75.245
63 1.0(DL+ EQUP +WIND X)-11.582 1354.396
5.587
64 1.0(DL+ EQUP -WIND X) 0.253 1342.858
5.481
65 1.0(DL+ EQUP+LL +WIND-13.171
X)
1716.205
9.455
66 1.0(DL+ EQUP+LL -WIND X)
-1.337 1704.667
9.349
67 1.0(DL+ EQUP +WIND Z) -5.667 1349.31
18.148
68 1.0(DL+ EQUP -WIND Z) -5.662 1347.944
-7.08
69 1.0(DL+ EQUP+LL +WIND -7.257
Z)
1711.119
22.016
70 1.0(DL+ EQUP+LL -WIND Z)
-7.251 1709.753
-3.212
1017 50 1.0(DL+50%LL+EQUP)
1.11 234.058
-3.332
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
103.356 382.956
17.965
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-101.136
85.161
-24.63
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
103.784 354.291
19.961
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-100.709
56.496
-22.634
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
33.266 325.083
41.725
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-31.046 143.034
-48.389
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
33.693 296.419
43.721
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-30.618 114.369
-46.394
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
32.42 289.765
12.069
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-30.2 178.352
-18.734
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
32.848
261.1
14.065
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-29.773 149.687
-16.738
63 1.0(DL+ EQUP +WIND X) -3.69 200.063
-1.401
64 1.0(DL+ EQUP -WIND X) 6.765 210.725
-1.272
65 1.0(DL+ EQUP+LL +WIND -4.546
X)
257.392
-5.393
66 1.0(DL+ EQUP+LL -WIND X)
5.909 268.054
-5.264
67 1.0(DL+ EQUP +WIND Z) 1.546 205.973
-0.959
68 1.0(DL+ EQUP -WIND Z) 1.529 204.815
-1.714
69 1.0(DL+ EQUP+LL +WIND Z)0.69 263.302
-4.951
70 1.0(DL+ EQUP+LL -WIND Z)
0.673 262.144
-5.706
1018 50 1.0(DL+50%LL+EQUP) 13.832 1183.86
2.402
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
236.463 1321.723
60.529
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-208.798 1045.998
-55.726
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
235.917 1172.062
60.738
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-209.344 896.337
-55.518

11.965
48.768
-38.286
55.512
-31.541
10.992
235.573
-213.59
233.123
-216.04
633.861
-611.878
631.411
-614.328
209.47
-187.487
207.02
-189.937
8.696
8.387
13.596
13.287
38.263
-21.18
43.163
-16.28
-1.535
41.606
-44.676
42.923
-43.359
90.789
-93.859
92.106
-92.542
29.907
-32.977
31.225
-31.66
-0.339
-0.096
-2.973
-2.73
0.63
-1.065
-2.004
-3.7
2.518
143.077
-138.041
142.893
-138.226

0.34
0.142
-0.116
0.224
-0.033
0.079
19.993
-19.836
19.999
-19.83
20.275
-20.117
20.281
-20.112
9.52
-9.362
9.526
-9.356
-0.152
0.321
-0.164
0.31
0.406
-0.237
0.394
-0.248
0.083
9.148
-8.983
9.129
-9.002
9.836
-9.671
9.817
-9.69
4.469
-4.304
4.45
-4.323
0.044
0.083
0.082
0.121
-0.327
0.454
-0.289
0.492
0.443
19.13
-18.245
19.067
-18.308

-45.317
-18.113
-17.982
-23.525
-23.393
-7.238
437.476
-451.952
438.577
-450.85
134.046
-148.522
135.148
-147.421
130.496
-144.973
131.598
-143.871
7.898
-20.171
5.694
-22.374
-6.171
-6.102
-8.374
-8.305
-2.279
215.415
-219.973
215.625
-219.762
66.106
-70.664
66.317
-70.454
64.327
-68.885
64.538
-68.675
7.946
-12.083
7.525
-12.504
-2.079
-2.058
-2.5
-2.479
-10.697
449.898
-471.293
450.878
-470.313

55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
83.721 1245.433 163.945
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-56.056 1122.287 -159.141
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
83.175 1095.773 164.153
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-56.602 972.626 -158.933
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
81.928 1230.321
53.533
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-54.263
1137.4
-48.73
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
81.382 1080.66
53.741
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-54.809 987.739
-48.521
63 1.0(DL+ EQUP +WIND X) 3.627 1032.212
2.888
64 1.0(DL+ EQUP -WIND X) 22.946 1036.187
2.332
65 1.0(DL+ EQUP+LL +WIND X)
4.719 1331.534
2.471
66 1.0(DL+ EQUP+LL -WIND 24.038
X)
1335.508
1.915
67 1.0(DL+ EQUP +WIND Z) 13.292 1033.165
12.042
68 1.0(DL+ EQUP -WIND Z) 13.28 1035.234
-6.822
69 1.0(DL+ EQUP+LL +WIND14.384
Z)
1332.486
11.625
70 1.0(DL+ EQUP+LL -WIND 14.372
Z)
1334.556
-7.238
1019 50 1.0(DL+50%LL+EQUP)
-7.839 1169.869
-11.163
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
287.533 1692.675
54.702
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-303.211 647.062
-77.028
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
285.819 1517.704
55.388
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-304.926 472.091
-76.342
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
84.914 1349.394 188.393
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-100.592 990.343 -210.719
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
83.2 1174.423 189.079
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-102.306 815.372 -210.033
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
82.538 1333.484
50.732
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-98.215 1006.253
-73.058
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
80.823 1158.513
51.418
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-99.93 831.282
-72.372
63 1.0(DL+ EQUP +WIND X) -21.99 978.503
-10.586
64 1.0(DL+ EQUP -WIND X) 2.883 1011.292
-10.368
65 1.0(DL+ EQUP+LL +WIND-18.561
X)
1328.445
-11.959
66 1.0(DL+ EQUP+LL -WIND X)
6.312 1361.234
-11.74
67 1.0(DL+ EQUP +WIND Z) -9.544 993.568
1.752
68 1.0(DL+ EQUP -WIND Z) -9.563 996.228
-22.706
69 1.0(DL+ EQUP+LL +WIND -6.115
Z)
1343.51
0.379
70 1.0(DL+ EQUP+LL -WIND Z)
-6.134 1346.17
-24.078
1020 50 1.0(DL+50%LL+EQUP)
1.729 1137.498
17.24
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
319.084 1417.357
85.295
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-315.626 857.639
-50.814
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
319.579 1272.301
85.947
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-315.131 712.583
-50.162
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
101.361 1234.622 225.136
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-97.903 1040.375 -190.656
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
101.856 1089.566 225.788
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-97.408 895.318 -190.004
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
98.832 1235.112
81.75
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-95.374 1039.884
-47.269
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
99.327 1090.056
82.402
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-94.879 894.828
-46.617
63 1.0(DL+ EQUP +WIND X)-10.015 1001.109
17.698
64 1.0(DL+ EQUP -WIND X) 14.462 983.775
18.086

392.986
-387.95
392.801
-388.135
126.107
-121.071
125.923
-121.256
3.003
1.664
3.372
2.033
24.627
-19.96
24.996
-19.591
-10.085
155.857
-176.027
156.179
-175.704
495.083
-515.253
495.405
-514.93
146.374
-166.543
146.696
-166.221
-10.032
-9.493
-10.677
-10.137
19.825
-39.35
19.181
-39.995
11.2
180.601
-158.2
180.886
-157.915
529.851
-507.45
530.136
-507.165
172.079
-149.678
172.364
-149.393
11.018
11.954

14.116
-13.23
14.052
-13.294
8.101
-7.216
8.038
-7.279
0.251
0.508
0.378
0.635
-0.095
0.853
0.033
0.98
0.615
16.581
-15.351
16.496
-15.436
13.22
-11.99
13.135
-12.075
7.404
-6.175
7.32
-6.259
0.483
0.577
0.653
0.747
0.532
0.529
0.701
0.698
0.684
16.404
-15.035
16.309
-15.13
15.511
-14.142
15.416
-14.237
7.906
-6.537
7.81
-6.632
0.797
0.381

133.867
-155.262
134.847
-154.282
130.17
-151.565
131.15
-150.585
10.439
-29.874
8.479
-31.834
-9.723
-9.712
-11.683
-11.672
7.435
597.96
-583.091
599.131
-581.921
192.741
-177.871
193.911
-176.701
188.043
-173.173
189.213
-172.003
32.018
-14.808
29.677
-17.148
8.605
8.605
6.265
6.264
-0.018
606.976
-607.012
606.59
-607.398
190.415
-190.451
190.029
-190.837
185.618
-185.654
185.232
-186.04
21.988
-22.796

65 1.0(DL+ EQUP+LL +WIND-11.005


X)
1291.222
16.395
66 1.0(DL+ EQUP+LL -WIND 13.473
X)
1273.888
16.783
67 1.0(DL+ EQUP +WIND Z) 2.229 993.123
30.101
68 1.0(DL+ EQUP -WIND Z) 2.218 991.761
5.684
69 1.0(DL+ EQUP+LL +WIND Z)1.24 1283.236
28.797
70 1.0(DL+ EQUP+LL -WIND Z)
1.228 1281.874
4.38
1021 50 1.0(DL+50%LL+EQUP)
1.557 1289.906
27.784
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
299.892 1305.405 102.279
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-296.778 1274.407
-46.71
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
299.23 1140.43 103.105
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-297.439 1109.432
-45.883
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
95.13 1315.547 256.238
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-92.016 1264.264 -200.669
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
94.468 1150.573 257.065
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-92.677 1099.29 -199.843
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
92.805 1312.385
98.857
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-89.691 1267.427
-43.288
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
92.143 1147.41
99.683
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-90.352 1102.452
-42.461
63 1.0(DL+ EQUP +WIND X) -9.791 1125.079
28.528
64 1.0(DL+ EQUP -WIND X) 11.582 1124.783
28.694
65 1.0(DL+ EQUP+LL +WIND -8.468
X)
1455.028
26.875
66 1.0(DL+ EQUP+LL -WIND 12.905
X)
1454.732
27.041
67 1.0(DL+ EQUP +WIND Z) 0.891 1125.818
41.177
68 1.0(DL+ EQUP -WIND Z)
0.9 1124.044
16.046
69 1.0(DL+ EQUP+LL +WIND Z)
2.214 1455.767
39.523
70 1.0(DL+ EQUP+LL -WIND Z)
2.223 1453.993
14.392
1022 50 1.0(DL+50%LL+EQUP)
4.562 1636.977
28.123
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
273.433 1906.876 133.602
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-264.309 1367.078
-77.356
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
274.196 1700.607 134.554
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-263.546 1160.809
-76.405
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
88.836 1760.296 341.237
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-79.713 1513.658 -284.991
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
89.6 1554.027 342.188
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-78.949 1307.389 -284.039
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
86.789 1748.775 126.446
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-77.666 1525.179
-70.2
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
87.552 1542.506 127.398
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-76.902 1318.91
-69.249
63 1.0(DL+ EQUP +WIND X) -3.841 1438.03
29.052
64 1.0(DL+ EQUP -WIND X) 14.491 1423.386
29.098
65 1.0(DL+ EQUP+LL +WIND -5.368
X)
1850.568
27.149
66 1.0(DL+ EQUP+LL -WIND 12.964
X)
1835.924
27.194
67 1.0(DL+ EQUP +WIND Z) 5.317 1432.085
44.801
68 1.0(DL+ EQUP -WIND Z) 5.333 1429.331
13.348
69 1.0(DL+ EQUP+LL +WIND Z)3.79 1844.623
42.898
70 1.0(DL+ EQUP+LL -WIND Z)
3.806 1841.869
11.445
1023 50 1.0(DL+50%LL+EQUP)
-1.458 1911.383
21.339
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
338.717 1941.503
158.16
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-341.633 1881.263 -115.482
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
338.7 1693.639 159.334

10.447
11.383
40.353
-17.382
39.783
-17.952
17.918
202.661
-166.825
203.095
-166.391
584.663
-548.827
585.097
-548.393
194.291
-158.455
194.725
-158.021
18.145
18.559
17.277
17.691
47.693
-10.989
46.825
-11.857
16.741
263.956
-230.475
264.64
-229.791
751.875
-718.394
752.56
-717.71
247.724
-214.242
248.408
-213.558
17.366
17.484
15.998
16.115
52.654
-17.805
51.286
-19.173
12.05
341.491
-317.391
342.118

0.988
0.571
0.747
0.432
0.937
0.622
0.442
17.428
-16.544
17.354
-16.617
19.504
-18.62
19.431
-18.693
8.966
-8.082
8.893
-8.155
0.407
0.331
0.553
0.477
0.259
0.479
0.405
0.625
0.433
22.517
-21.651
22.437
-21.731
16.912
-16.045
16.831
-16.126
9.56
-8.694
9.48
-8.774
0.365
0.34
0.526
0.501
0.188
0.517
0.349
0.678
0.511
25.091
-24.069
24.967

22.759
-22.024
-0.397
-0.411
0.375
0.361
0.051
592.411
-592.309
592.926
-591.794
185.773
-185.67
186.287
-185.155
181.163
-181.061
181.678
-180.546
20.9
-19.768
19.871
-20.797
0.584
0.547
-0.445
-0.481
-2.646
566.293
-571.584
565.869
-572.008
175.617
-180.909
175.193
-181.333
171.273
-176.564
170.849
-176.988
15.421
-21.56
16.269
-20.713
-3.046
-3.093
-2.198
-2.245
4.422
806.565
-797.721
806.197

54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-341.65 1633.398 -114.308 -316.764
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
105.059 1971.733 447.598 1038.207
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-107.975 1851.033
-404.92 -1014.11
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
105.042 1723.868 448.772 1038.834
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-107.992 1603.168 -403.746 -1013.48
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
102.553 1960.517 153.785 331.382
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-105.469 1862.248 -111.106 -307.282
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
102.536 1712.653 154.959 332.009
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-105.486 1614.384 -109.933 -306.655
63 1.0(DL+ EQUP +WIND X)-12.206 1663.507
22.512
12.675
64 1.0(DL+ EQUP -WIND X) 9.257 1663.53
22.514
12.679
65 1.0(DL+ EQUP+LL +WIND-12.173
X)
2159.236
20.164
11.42
66 1.0(DL+ EQUP+LL -WIND X)9.29 2159.258
20.167
11.425
67 1.0(DL+ EQUP +WIND Z) -1.494 1664.848
41.385
55.941
68 1.0(DL+ EQUP -WIND Z) -1.456 1662.189
3.641
-30.587
69 1.0(DL+ EQUP+LL +WIND Z)
-1.46 2160.577
39.038
54.686
70 1.0(DL+ EQUP+LL -WIND Z)
-1.423 2157.917
1.293
-31.841
1024 50 1.0(DL+50%LL+EQUP)
-3.945 1869.917
18.879
12.885
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
237.578 1895.526 149.385 318.133
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-245.469 1844.308 -111.627 -292.363
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
238.584 1652.969 150.446 318.876
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-244.464 1601.751 -110.566
-291.62
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
71.649 1923.057 416.243 942.248
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-79.54 1816.777 -378.485 -916.477
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
72.654 1680.499 417.304
942.99
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-78.535 1574.22 -377.424 -915.735
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
69.901 1918.755
142.54 302.527
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-77.792 1821.079 -104.782 -276.756
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
70.906 1676.197 143.601 303.269
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-76.787 1578.522 -103.721 -276.014
63 1.0(DL+ EQUP +WIND X)-10.232 1627.554
19.947
13.644
64 1.0(DL+ EQUP -WIND X) 4.351 1627.165
19.933
13.611
65 1.0(DL+ EQUP+LL +WIND-12.242
X)
2112.668
17.825
12.159
66 1.0(DL+ EQUP+LL -WIND X)
2.341 2112.28
17.811
12.126
67 1.0(DL+ EQUP +WIND Z) -2.961 1628.492
37.903
53.662
68 1.0(DL+ EQUP -WIND Z) -2.92 1626.227
1.977
-26.407
69 1.0(DL+ EQUP+LL +WIND -4.971
Z)
2113.607
35.781
52.177
70 1.0(DL+ EQUP+LL -WIND Z)-4.93 2111.341
-0.145
-27.892
1025 50 1.0(DL+50%LL+EQUP) -17.687 1395.066
16.095
12.603
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
276.038 1991.228 106.253 235.781
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-311.413 798.905
-74.063 -210.575
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
276.598 1826.171 103.939 233.977
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-310.853 633.848
-76.377 -212.379
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
74.387 1607.491
265.01 630.645
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-109.762 1182.641
-232.82 -605.439
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
74.946 1442.435 262.696 628.841
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-109.202 1017.585 -235.134 -607.243
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
72.158 1607.689
95.391 209.267
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-107.533 1182.443
-63.201 -184.061
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
72.717 1442.633
93.077 207.463
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-106.973 1017.387
-65.515 -185.865
63 1.0(DL+ EQUP +WIND X)-25.525 1214.516
13.822
10.945

-24.193
15.466
-14.444
15.342
-14.568
9.87
-8.848
9.746
-8.972
0.272
0.502
0.52
0.751
0.291
0.483
0.539
0.732
0.391
22.053
-21.272
21.925
-21.4
14.373
-13.592
14.245
-13.72
8.81
-8.029
8.682
-8.157
0.11
0.415
0.367
0.671
0.342
0.183
0.599
0.439
0.017
19.083
-19.05
19.056
-19.077
25.49
-25.457
25.463
-25.484
10.809
-10.776
10.782
-10.803
-0.077

-798.09
255.522
-246.678
255.154
-247.046
249.56
-240.716
249.192
-241.084
28.331
-20.223
29.067
-19.487
4.103
4.004
4.839
4.741
6.476
554.807
-541.856
553.454
-543.209
178.024
-165.072
176.67
-166.426
174.023
-161.072
172.67
-162.425
21.04
-10.795
23.747
-8.089
5.168
5.077
7.874
7.783
18.884
607.789
-570.021
606.229
-571.581
203.184
-165.416
201.624
-166.976
198.851
-161.083
197.29
-162.643
33.843

64 1.0(DL+ EQUP -WIND X) -8.73 1245.504


13.74
65 1.0(DL+ EQUP+LL +WIND-26.645
X)
1544.629
18.45
66 1.0(DL+ EQUP+LL -WIND X)-9.85 1575.616
18.368
67 1.0(DL+ EQUP +WIND Z)-17.119 1228.954
27.034
68 1.0(DL+ EQUP -WIND Z) -17.136 1231.066
0.528
69 1.0(DL+ EQUP+LL +WIND-18.239
Z)
1559.067
31.662
70 1.0(DL+ EQUP+LL -WIND-18.256
Z)
1561.178
5.156
1026 50 1.0(DL+50%LL+EQUP) -10.352 558.547
10.628
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
216.001 1536.466
54.198
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-236.706 -419.372
-32.942
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
218.048 1482.439
52.761
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-234.66 -473.399
-34.38
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
60.733 978.932 137.217
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-81.437 138.163 -115.962
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
62.779 924.905
135.78
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-79.391
84.136 -117.399
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
58.952 891.366
51.623
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-79.657 225.728
-30.368
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
60.999 837.339
50.186
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-77.611 171.701
-31.805
63 1.0(DL+ EQUP +WIND X)-14.798 528.908
9.175
64 1.0(DL+ EQUP -WIND X) -1.814 480.132
9.206
65 1.0(DL+ EQUP+LL +WIND -18.89
X)
636.962
12.049
66 1.0(DL+ EQUP+LL -WIND X)
-5.907 588.186
12.08
67 1.0(DL+ EQUP +WIND Z) -8.286 511.529
17.126
68 1.0(DL+ EQUP -WIND Z) -8.327 497.511
1.255
69 1.0(DL+ EQUP+LL +WIND-12.378
Z)
619.583
20
70 1.0(DL+ EQUP+LL -WIND-12.419
Z)
605.565
4.129
1027 50 1.0(DL+50%LL+EQUP)
1.337 232.634
3.435
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
74.066 349.996
24.746
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-71.392 115.271
-17.877
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
74.626 320.999
22.728
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-70.833
86.275
-19.895
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
24.828 313.626
48.519
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-22.155 151.641
-41.65
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
25.388
284.63
46.501
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-21.595 122.645
-43.668
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
23.833 278.711
18.846
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-21.16 186.556
-11.976
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
24.393 249.715
16.827
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-20.6
157.56
-13.995
63 1.0(DL+ EQUP +WIND X) -3.043 198.386
1.351
64 1.0(DL+ EQUP -WIND X) 6.836 208.888
1.482
65 1.0(DL+ EQUP+LL +WIND -4.163
X)
256.379
5.388
66 1.0(DL+ EQUP+LL -WIND X)
5.716 266.881
5.518
67 1.0(DL+ EQUP +WIND Z) 1.879
203.1
1.795
68 1.0(DL+ EQUP -WIND Z) 1.914 204.174
1.038
69 1.0(DL+ EQUP+LL +WIND Z)0.76 261.093
5.832
70 1.0(DL+ EQUP+LL -WIND Z)
0.794 262.167
5.075
1028 50 1.0(DL+50%LL+EQUP) 26.186 1181.683
-10.172
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
184.206 1345.427
56.66
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-131.834 1017.939
-77.003

10.652
14.554
14.261
41.548
-19.951
45.157
-16.342
-1.27
132.145
-134.685
132.561
-134.269
400.084
-402.624
400.5
-402.208
126.695
-129.235
127.111
-128.819
-0.768
-0.94
-1.6
-1.772
22.232
-23.94
21.4
-24.772
1.778
44.935
-41.38
43.573
-42.742
94.124
-90.568
92.761
-91.93
33.229
-29.673
31.866
-31.035
0.292
0.539
3.017
3.263
1.264
-0.433
3.989
2.291
-10.038
137.2
-157.275

0.056
-0.023
0.111
0.516
-0.537
0.571
-0.483
0.773
23.896
-22.351
23.777
-22.469
26.958
-25.413
26.84
-25.531
12.714
-11.169
12.596
-11.288
0.604
0.705
0.841
0.941
1.209
0.099
1.446
0.336
0.106
7.942
-7.73
7.926
-7.746
8.744
-8.533
8.728
-8.548
3.959
-3.747
3.943
-3.763
0.182
-0.002
0.213
0.029
-0.286
0.467
-0.255
0.498
0.192
29.503
-29.118

0.804
36.964
3.925
17.352
17.295
20.473
20.416
13.063
550.904
-524.778
548.322
-527.36
181.4
-155.274
178.818
-157.856
177.442
-151.317
174.861
-153.899
25.5
-4.538
30.664
0.625
10.503
10.459
15.667
15.622
-3.315
152.224
-158.855
152.46
-158.619
46.746
-53.377
46.982
-53.141
44.631
-51.262
44.867
-51.026
6.556
-12.715
6.084
-13.187
-3.032
-3.127
-3.504
-3.599
-22.032
306.745
-350.809

53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
182.695 1240.251
55.948
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-133.345 912.763
-77.716
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
77.287 1509.24 174.937
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-24.915 854.126 -195.281
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
75.776 1404.064 174.225
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-26.426
748.95 -195.993
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
75.264 1304.365
48.468
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-22.891 1059.001
-68.811
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
73.752 1199.189
47.755
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-24.403 953.826
-69.524
63 1.0(DL+ EQUP +WIND X) 15.473 1074.216
-10.6
64 1.0(DL+ EQUP -WIND X) 33.877 1078.799
-11.169
65 1.0(DL+ EQUP+LL +WIND18.496
X)
1284.568
-9.174
66 1.0(DL+ EQUP+LL -WIND 36.899
X)
1289.15
-9.744
67 1.0(DL+ EQUP +WIND Z) 24.639 1097.395
0.504
68 1.0(DL+ EQUP -WIND Z) 24.711 1055.62
-22.272
69 1.0(DL+ EQUP+LL +WIND27.662
Z)
1307.746
1.929
70 1.0(DL+ EQUP+LL -WIND 27.733
Z)
1265.972
-20.847
1029 50 1.0(DL+50%LL+EQUP) -12.376
902.25
1.656
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
176.061 1287.389
72.465
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-200.813 517.112
-69.153
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
174.599 1166.758
71.114
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-202.275 396.481
-70.504
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
47.915 1285.258 219.675
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-72.668 519.243 -216.362
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
46.454 1164.627 218.324
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-74.129 398.612 -217.713
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
45.706 1084.482
69.004
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-70.458 720.018
-65.691
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
44.244 963.852
67.653
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-71.92 599.387
-67.042
63 1.0(DL+ EQUP +WIND X)-24.504 767.979
0.276
64 1.0(DL+ EQUP -WIND X) -3.172 795.259
0.335
65 1.0(DL+ EQUP+LL +WIND -21.58
X)
1009.241
2.977
66 1.0(DL+ EQUP+LL -WIND X)
-0.248 1036.521
3.037
67 1.0(DL+ EQUP +WIND Z)-14.001
799.64
14.578
68 1.0(DL+ EQUP -WIND Z) -13.675 763.599
-13.967
69 1.0(DL+ EQUP+LL +WIND-11.077
Z)
1040.901
17.28
70 1.0(DL+ EQUP+LL -WIND-10.751
Z)
1004.861
-11.265
1030 50 1.0(DL+50%LL+EQUP)
2.041 958.192
-6.177
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
203.751 1132.546
57.301
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-199.67 783.839
-69.655
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
203.392 994.724
59.278
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-200.029 646.017
-67.678
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
66.441 1025.476 186.587
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-62.36 890.908 -198.941
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
66.082 887.655 188.564
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-62.719 753.086 -196.964
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
64.024 1014.947
53.902
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-59.943 901.437
-66.256
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
63.665 877.126
55.879
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-60.302 763.615
-64.279

137.44
-157.035
397.405
-417.481
397.646
-417.24
119.054
-139.129
119.294
-138.889
-9.099
-10.495
-9.581
-10.976
14.54
-34.135
14.059
-34.616
-3.53
155.866
-162.927
156.458
-162.336
485.769
-492.83
486.36
-492.238
147.679
-154.74
148.271
-154.148
-3.135
-2.743
-4.318
-3.926
27.68
-33.557
26.496
-34.74
-9.943
147.271
-167.156
150.103
-164.325
468.731
-488.616
471.563
-485.784
138.816
-158.702
141.648
-155.87

29.454
-29.166
24.116
-23.731
24.068
-23.78
12.596
-12.212
12.548
-12.26
-0.937
1.225
-0.84
1.321
-0.686
0.974
-0.589
1.071
0.32
20.688
-20.048
20.617
-20.118
12.74
-12.1
12.67
-12.17
8.01
-7.369
7.939
-7.44
-0.663
1.163
-0.523
1.304
0.245
0.255
0.385
0.395
0.461
15.256
-14.335
15.212
-14.379
14.29
-13.369
14.246
-13.413
7.19
-6.269
7.146
-6.313

308.681
-348.873
83.821
-127.886
85.757
-125.95
79.299
-123.363
81.235
-121.427
-0.671
-39.521
-4.543
-43.393
-19.998
-20.194
-23.87
-24.067
8.787
360.031
-342.458
361.594
-340.895
121.294
-103.72
122.856
-102.158
116.874
-99.3
118.436
-97.738
29.467
-8.769
26.342
-11.894
10.551
10.147
7.426
7.022
-2.412
358.711
-363.534
359.472
-362.772
113.128
-117.951
113.89
-117.189
108.605
-113.428
109.367
-112.666

63 1.0(DL+ EQUP +WIND X) -8.986


828.74
-4.393
64 1.0(DL+ EQUP -WIND X) 12.349
812
-4.007
65 1.0(DL+ EQUP+LL +WIND -8.268
X)
1104.384
-8.347
66 1.0(DL+ EQUP+LL -WIND 13.068
X)
1087.644
-7.962
67 1.0(DL+ EQUP +WIND Z) 1.522 821.398
8.067
68 1.0(DL+ EQUP -WIND Z) 1.841 819.342
-16.466
69 1.0(DL+ EQUP+LL +WIND Z)2.24 1097.042
4.112
70 1.0(DL+ EQUP+LL -WIND Z)2.56 1094.986
-20.421
1031 50 1.0(DL+50%LL+EQUP)
2.313 1054.831
-12.527
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
192.22 1060.254
56.4
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-187.594 1049.408
-81.455
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
191.081 900.221
58.695
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-188.733 889.375
-79.161
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
63.251 1059.378 198.882
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-58.624 1050.284 -223.937
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
62.111 899.345 201.177
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-59.764 890.251 -221.643
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
60.744 1058.264
53.491
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-56.117 1051.397
-78.546
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
59.604 898.231
55.786
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-57.257 891.364
-76.251
63 1.0(DL+ EQUP +WIND X) -8.234 895.013
-10.3
64 1.0(DL+ EQUP -WIND X) 10.581 894.583
-10.166
65 1.0(DL+ EQUP+LL +WIND -5.954
X)
1215.079
-14.889
66 1.0(DL+ EQUP+LL -WIND 12.861
X)
1214.649
-14.755
67 1.0(DL+ EQUP +WIND Z) 1.106 894.436
2.53
68 1.0(DL+ EQUP -WIND Z) 1.242
895.16
-22.996
69 1.0(DL+ EQUP+LL +WIND Z)
3.385 1214.502
-2.059
70 1.0(DL+ EQUP+LL -WIND Z)
3.521 1215.226
-27.585
1032 50 1.0(DL+50%LL+EQUP)
1.792 1276.629
-14.778
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
175.498 1430.594
82.582
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-171.915 1122.663 -112.138
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
175.997 1228.398
85.05
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-171.415 920.467 -109.671
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
57.475 1326.708 273.922
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-53.892 1226.549 -303.477
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
57.974 1124.511 276.389
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-53.392 1024.353
-301.01
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
55.223 1326.451
76.322
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-51.64 1226.806 -105.877
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
55.723 1124.255
78.789
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-51.141 1024.61
-103.41
63 1.0(DL+ EQUP +WIND X) -5.899 1081.174
-12.336
64 1.0(DL+ EQUP -WIND X) 10.48 1067.691
-12.285
65 1.0(DL+ EQUP+LL +WIND -6.897
X)
1485.566
-17.271
66 1.0(DL+ EQUP+LL -WIND X)
9.482 1472.084
-17.219
67 1.0(DL+ EQUP +WIND Z) 2.232 1073.988
3.606
68 1.0(DL+ EQUP -WIND Z)
2.35 1074.876
-28.228
69 1.0(DL+ EQUP+LL +WIND Z)
1.233 1478.381
-1.328
70 1.0(DL+ EQUP+LL -WIND Z)
1.351 1479.269
-33.162
1033 50 1.0(DL+50%LL+EQUP)
-1.438 1405.99
-24.318
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
244.971 1418.504 107.147

-7.585
-6.636
-13.249
-12.3
21.357
-35.579
15.693
-41.242
-14.584
155.744
-184.912
159.057
-181.599
508.502
-537.669
511.814
-534.357
148.27
-177.438
151.583
-174.125
-11.443
-11.1
-18.068
-17.725
17.969
-40.512
11.344
-47.137
-18.527
209.519
-246.572
212.893
-243.198
659.364
-696.418
662.738
-693.044
194.679
-231.733
198.053
-228.359
-15.215
-15.091
-21.963
-21.839
19.78
-50.086
13.032
-56.834
-29.108
295.35

0.654
0.178
0.743
0.267
0.569
0.264
0.658
0.353
0.319
15.95
-15.312
15.899
-15.364
17.731
-17.093
17.68
-17.144
8.062
-7.424
8.01
-7.475
0.254
0.281
0.357
0.384
0.146
0.389
0.249
0.492
0.278
25.659
-25.103
25.62
-25.143
17.813
-17.258
17.774
-17.297
10.311
-9.756
10.272
-9.795
0.448
0.029
0.526
0.108
0.076
0.401
0.154
0.479
0.173
35.808

16.858
-20.158
15.335
-21.681
-1.457
-1.843
-2.98
-3.366
-2.412
349.178
-354.002
350.517
-352.662
110.362
-115.186
111.701
-113.846
105.739
-110.563
107.078
-109.224
15.819
-17.964
13.14
-20.643
-0.959
-1.186
-3.638
-3.866
-2
336.273
-340.272
336.442
-340.104
106.407
-110.407
106.576
-110.238
102.03
-106.029
102.199
-105.861
13.599
-17.261
13.262
-17.598
-1.731
-1.931
-2.068
-2.269
0.878
576.253

52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-247.846 1393.475 -155.782
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
244.416 1173.847 110.229
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-248.4 1148.818
-152.7
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
77.394 1413.931 384.611
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-80.269 1398.048 -433.247
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
76.84 1169.274 387.693
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-80.824 1153.392 -430.165
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
74.315 1414.418 103.586
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-77.19 1397.561 -152.221
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
73.761 1169.761 106.668
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-77.745 1152.904 -149.139
63 1.0(DL+ EQUP +WIND X) -12.87 1161.075
-21.234
64 1.0(DL+ EQUP -WIND X) 8.886 1161.59
-21.237
65 1.0(DL+ EQUP+LL +WIND-11.762
X)
1650.389
-27.398
66 1.0(DL+ EQUP+LL -WIND X)
9.995 1650.904
-27.401
67 1.0(DL+ EQUP +WIND Z) -2.068
1160.7
-1.043
68 1.0(DL+ EQUP -WIND Z) -1.916 1161.965
-41.429
69 1.0(DL+ EQUP+LL +WIND Z)
-0.96 1650.014
-7.207
70 1.0(DL+ EQUP+LL -WIND Z)
-0.807 1651.279
-47.593
1034 50 1.0(DL+50%LL+EQUP)
-4.333 1460.273
-9.945
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
177.713 1471.753 116.444
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-186.379 1448.793 -136.334
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
178.971 1224.813 119.606
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-185.121 1201.853 -133.172
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
53.827 1467.717
374.3
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-62.493 1452.829
-394.19
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
55.085 1220.777 377.462
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-61.235 1205.888 -391.028
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
51.664 1468.141 110.371
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-60.33 1452.405 -130.262
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
52.922 1221.201 113.534
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-59.072 1205.465 -127.099
63 1.0(DL+ EQUP +WIND X)-10.708 1213.838
-6.78
64 1.0(DL+ EQUP -WIND X) 4.558 1212.827
-6.786
65 1.0(DL+ EQUP+LL +WIND-13.224
X)
1707.719
-13.104
66 1.0(DL+ EQUP+LL -WIND X)
2.042 1706.708
-13.11
67 1.0(DL+ EQUP +WIND Z) -3.132 1212.75
12.442
68 1.0(DL+ EQUP -WIND Z) -3.018 1213.915
-26.008
69 1.0(DL+ EQUP+LL +WIND -5.648
Z)
1706.631
6.118
70 1.0(DL+ EQUP+LL -WIND Z)
-5.534 1707.796
-32.332
1035 50 1.0(DL+50%LL+EQUP)
-6.876 1191.702
-9.904
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
194.645 1661.67
75.469
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-208.398 721.734
-95.278
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
195.746 1503.325
79.034
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-207.297
563.39
-91.714
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
57.393 1342.685 224.321
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-71.146 1040.72 -244.129
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
58.494 1184.34 227.885
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-70.045 882.375 -240.565
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
55.031 1342.414
65.397
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-68.784 1040.99
-85.206
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
56.132 1184.069
68.961

-353.566
299.575
-349.341
981.181
-1039.4
985.406
-1035.17
285.658
-343.875
289.883
-339.649
-24.881
-24.885
-33.332
-33.336
21.319
-71.084
12.868
-79.536
-14.119
287.644
-315.883
291.716
-311.812
904.297
-932.535
908.368
-928.464
272.442
-300.681
276.513
-296.61
-10.038
-10.059
-18.18
-18.201
32.673
-52.769
24.53
-60.911
-11.172
196.008
-218.351
199.899
-214.46
561.029
-583.372
564.92
-579.481
171.13
-193.473
175.021

-35.461
35.775
-35.494
19.645
-19.298
19.612
-19.331
13.034
-12.687
13.001
-12.72
0.44
-0.159
0.506
-0.094
0.021
0.26
0.087
0.326
-0.095
30.414
-30.604
30.407
-30.61
16.098
-16.288
16.091
-16.294
10.823
-11.014
10.817
-11.02
0.157
-0.36
0.17
-0.347
-0.023
-0.18
-0.01
-0.167
0.035
21.228
-21.159
21.221
-21.166
34.148
-34.079
34.142
-34.086
13.281
-13.211
13.274

-574.497
576.959
-573.79
184.954
-183.198
185.66
-182.491
177.74
-175.984
178.446
-175.277
26.112
-22.943
24.699
-24.356
1.737
1.432
0.324
0.019
4.716
406.115
-396.683
404.979
-397.819
132.935
-123.502
131.798
-124.638
128.076
-118.644
126.94
-119.78
19.94
-12.78
22.212
-10.508
3.686
3.474
5.958
5.746
8.974
376.152
-358.205
374.484
-359.873
126.127
-108.179
124.458
-109.848
121.777
-103.83
120.109

62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-67.683 882.645
-81.641
63 1.0(DL+ EQUP +WIND X)-13.815 1014.991
-6.259
64 1.0(DL+ EQUP -WIND X) 2.265 1051.724
-6.42
65 1.0(DL+ EQUP+LL +WIND-16.017
X)
1331.681
-13.388
66 1.0(DL+ EQUP+LL -WIND X)
0.062 1368.413
-13.549
67 1.0(DL+ EQUP +WIND Z) -5.842 1033.166
7.411
68 1.0(DL+ EQUP -WIND Z) -5.709 1033.549
-20.09
69 1.0(DL+ EQUP+LL +WIND -8.044
Z)
1349.855
0.282
70 1.0(DL+ EQUP+LL -WIND Z)
-7.911 1350.238
-27.219
1036 50 1.0(DL+50%LL+EQUP)
-9.915 557.519
-2.423
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
164.649 1199.087
55.828
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-184.478
-84.05
-60.673
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
166.157 1151.695
58.908
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-182.969 -131.442
-57.593
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
45.749 806.797 170.935
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-65.578
308.24 -175.781
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
47.258 759.405 174.015
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-64.07 260.848 -172.701
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
43.735 765.143
53.366
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-63.565 349.895
-58.211
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
45.244
717.75
56.446
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-62.056 302.502
-55.131
63 1.0(DL+ EQUP +WIND X)-15.348 535.369
0.663
64 1.0(DL+ EQUP -WIND X) -1.464 484.883
0.651
65 1.0(DL+ EQUP+LL +WIND-18.366
X)
630.154
-5.496
66 1.0(DL+ EQUP+LL -WIND X)
-4.481 579.669
-5.508
67 1.0(DL+ EQUP +WIND Z) -8.473 507.977
11.257
68 1.0(DL+ EQUP -WIND Z) -8.339 512.275
-9.943
69 1.0(DL+ EQUP+LL +WIND-11.491
Z)
602.762
5.098
70 1.0(DL+ EQUP+LL -WIND-11.357
Z)
607.061
-16.102
1037 50 1.0(DL+50%LL+EQUP) 28.912 977.152
-6.25
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
115.269 1139.193
73.053
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-57.446 815.111
-85.554
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
114.263 1074.988
74.551
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-58.452 750.906
-84.056
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
57.853 1042.632 213.457
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-0.029 911.672 -225.958
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
56.846 978.427 214.955
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-1.036 847.467
-224.46
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
56.385 1038.634
63.355
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
1.439
915.67
-75.856
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
55.378 974.429
64.853
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
0.432 851.465
-74.358
63 1.0(DL+ EQUP +WIND X) 17.481 900.476
-4.326
64 1.0(DL+ EQUP -WIND X) 38.329 925.418
-5.178
65 1.0(DL+ EQUP+LL +WIND19.494
X)
1028.886
-7.323
66 1.0(DL+ EQUP+LL -WIND 40.342
X)
1053.828
-8.175
67 1.0(DL+ EQUP +WIND Z) 27.778 913.823
8.711
68 1.0(DL+ EQUP -WIND Z) 28.032 912.071
-18.215
69 1.0(DL+ EQUP+LL +WIND29.791
Z)
1042.233
5.714
70 1.0(DL+ EQUP+LL -WIND 30.045
Z)
1040.481
-21.211
1038 50 1.0(DL+50%LL+EQUP) -25.777 883.001
-8.99

-189.582
-7.103
-7.458
-14.886
-15.241
23.529
-38.09
15.746
-45.873
-10.626
135.307
-156.56
139.323
-152.544
428.373
-449.626
432.389
-445.61
129.236
-150.488
133.252
-146.472
-6.522
-6.698
-14.555
-14.73
18.924
-32.144
10.892
-40.176
-7.133
149.571
-163.837
151.373
-162.035
426.493
-440.758
428.294
-438.957
130.262
-144.528
132.064
-142.726
-4.473
-6.19
-8.076
-9.792
21.038
-31.701
17.436
-35.304
-11.156

-13.218
0.072
-0.016
0.086
-0.003
0.648
-0.593
0.662
-0.579
-0.085
25.243
-25.414
25.246
-25.412
22.793
-22.964
22.795
-22.961
11.315
-11.485
11.317
-11.483
0.042
-0.208
0.037
-0.213
0.575
-0.741
0.57
-0.746
0.232
23.011
-22.547
22.992
-22.567
13.935
-13.471
13.916
-13.491
8.748
-8.284
8.728
-8.303
0.603
-0.178
0.643
-0.139
0.113
0.312
0.153
0.351
0.235

-105.499
21.782
-7.171
25.119
-3.834
7.408
7.202
10.746
10.539
13.733
417.499
-390.032
414.964
-392.567
142.538
-115.071
140.003
-117.606
137.795
-110.328
135.26
-112.863
27.009
-4.612
32.079
0.458
11.317
11.08
16.387
16.15
-23.727
207.571
-255.024
208.745
-253.851
53.428
-100.881
54.601
-99.707
48.586
-96.039
49.759
-94.865
3.486
-48.592
1.138
-50.939
-22.216
-22.89
-24.563
-25.238
19.342

51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
61.749 1036.966
73.495
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-113.303 729.037
-91.475
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
63.577 938.632
76.142
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-111.474 630.704
-88.828
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
3.708 1048.684 242.941
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-55.262 717.319 -260.921
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
5.537
950.35 245.588
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-53.434 618.986 -258.274
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
2.057 961.784
69.053
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-53.611 804.219
-87.033
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
3.886
863.45
71.7
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-51.783 705.886
-84.386
63 1.0(DL+ EQUP +WIND X)-35.406 794.624
-6.489
64 1.0(DL+ EQUP -WIND X) -12.491 774.711
-6.197
65 1.0(DL+ EQUP+LL +WIND-39.063
X)
991.292
-11.783
66 1.0(DL+ EQUP+LL -WIND-16.148
X)
971.379
-11.491
67 1.0(DL+ EQUP +WIND Z)-24.093 794.735
10.866
68 1.0(DL+ EQUP -WIND Z) -23.803 774.601
-23.551
69 1.0(DL+ EQUP+LL +WIND-27.751
Z)
991.402
5.572
70 1.0(DL+ EQUP+LL -WIND-27.461
Z)
971.268
-28.845
1039 50 1.0(DL+50%LL+EQUP) 30.099 850.283
-4.887
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
116.698
1152.1
42.528
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-56.501 548.466
-52.302
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
115.203 1095.593
42.93
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-57.995
491.96
-51.9
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
61.213 1357.299 126.175
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-1.016 343.267 -135.948
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
59.718 1300.793 126.577
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-2.511 286.761 -135.546
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
57.55 1038.486
36.667
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
2.647
662.08
-46.441
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
56.055
981.98
37.069
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
1.152 605.574
-46.039
63 1.0(DL+ EQUP +WIND X) 23.837 783.096
-4.173
64 1.0(DL+ EQUP -WIND X) 33.371 804.457
-4.797
65 1.0(DL+ EQUP+LL +WIND26.827
X)
896.109
-4.977
66 1.0(DL+ EQUP+LL -WIND 36.361
X)
917.47
-5.601
67 1.0(DL+ EQUP +WIND Z) 28.642 763.366
3.947
68 1.0(DL+ EQUP -WIND Z) 28.566 824.188
-12.916
69 1.0(DL+ EQUP+LL +WIND31.632
Z)
876.378
3.143
70 1.0(DL+ EQUP+LL -WIND 31.555
Z)
937.201
-13.72
1040 50 1.0(DL+50%LL+EQUP)
-26.76 933.648
-3.034
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
109.629 1332.823
46.303
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-163.15 534.474
-52.37
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
111.194 1254.371
46.839
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-161.584 456.022
-51.834
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
21.48 1574.395 144.791
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-75.001 292.902 -150.859
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
23.046 1495.943 145.327
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-73.436
214.45 -150.323
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
16.29 1175.801
42.921
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-69.81 691.496
-48.989

156.619
-178.93
159.843
-175.706
502.359
-524.671
505.584
-521.447
147.689
-170
150.913
-166.776
-8.21
-7.653
-14.659
-14.102
25.744
-41.607
19.295
-48.056
-6.271
93.653
-106.196
94.664
-105.185
269.94
-282.483
270.952
-281.472
81.276
-93.819
82.287
-92.808
-4.657
-5.863
-6.68
-7.886
12.111
-22.632
10.089
-24.654
-5.287
101.121
-111.695
102.443
-110.373
318.768
-329.342
320.09
-328.021
95.046
-105.62

26.357
-25.887
26.358
-25.887
11.997
-11.527
11.997
-11.527
9.095
-8.626
9.096
-8.625
1.532
-1.062
1.532
-1.063
1.331
-0.86
1.33
-0.861
0.551
25.012
-23.91
25.033
-23.889
17.937
-16.835
17.958
-16.815
10.356
-9.254
10.377
-9.233
4.2
-3.056
4.158
-3.098
-0.386
1.53
-0.428
1.488
0.784
17.76
-16.193
17.607
-16.347
14.367
-12.799
14.213
-12.953
7.961
-6.393

251.394
-212.711
250.303
-213.802
96.861
-58.178
95.77
-59.269
91.948
-53.264
90.856
-54.355
44.415
-7.914
46.597
-5.732
18.62
17.881
20.802
20.063
-25.333
228.557
-279.224
230.271
-277.509
64.691
-115.358
66.405
-113.643
54.856
-105.523
56.571
-103.808
-8.958
-38.28
-12.387
-41.709
-23.705
-23.532
-27.134
-26.961
17.296
308.94
-274.348
308.51
-274.778
120.023
-85.431
119.593
-85.86
109.248
-74.656

61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
17.855 1097.349
43.458
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-68.245 613.044
-48.453
63 1.0(DL+ EQUP +WIND X)-32.945 843.554
-2.671
64 1.0(DL+ EQUP -WIND X) -17.445 866.839
-2.324
65 1.0(DL+ EQUP+LL +WIND-36.075
X)
1000.458
-3.744
66 1.0(DL+ EQUP+LL -WIND-20.575
X)
1023.742
-3.397
67 1.0(DL+ EQUP +WIND Z)-24.961 819.042
7.633
68 1.0(DL+ EQUP -WIND Z) -25.429 891.351
-12.628
69 1.0(DL+ EQUP+LL +WIND-28.091
Z)
975.946
6.561
70 1.0(DL+ EQUP+LL -WIND-28.559
Z)
1048.255
-13.701
1041 50 1.0(DL+50%LL+EQUP)
5.146 700.795
-18.583
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
152.623 912.004
18.345
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-142.331 489.587
-55.511
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
151.902 842.881
17.308
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-143.052 420.464
-56.547
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
57.036 949.544
93.297
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-46.743 452.046 -130.463
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
56.315 880.421
92.26
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-47.465 382.923 -131.499
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
51.632 807.623
16.27
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-41.339 593.967
-53.437
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
50.911
738.5
15.234
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-42.061 524.845
-54.473
63 1.0(DL+ EQUP +WIND X) -3.525 641.105
-19.762
64 1.0(DL+ EQUP -WIND X) 12.375
622.24
-19.478
65 1.0(DL+ EQUP+LL +WIND -2.083
X)
779.35
-17.688
66 1.0(DL+ EQUP+LL -WIND 13.818
X)
760.486
-17.404
67 1.0(DL+ EQUP +WIND Z) 4.666
620.69
-12.373
68 1.0(DL+ EQUP -WIND Z) 4.184 642.654
-26.866
69 1.0(DL+ EQUP+LL +WIND Z)
6.109 758.936
-10.3
70 1.0(DL+ EQUP+LL -WIND Z)
5.626
780.9
-24.793
1042 50 1.0(DL+50%LL+EQUP)
1.388 762.257
-16.929
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
141.476 826.952
22.959
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-138.701 697.562
-56.818
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
140.791 747.228
21.7
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-139.386 617.839
-58.078
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
50.939 959.137
105.33
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-48.163 565.377 -139.188
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
50.254 879.414
104.07
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-48.848 485.653 -140.448
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
45.607 823.564
21.213
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-42.831
700.95
-55.072
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
44.922 743.841
19.954
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-43.516 621.226
-56.332
63 1.0(DL+ EQUP +WIND X) -6.54 683.135
-18.221
64 1.0(DL+ EQUP -WIND X) 7.946 681.932
-18.157
65 1.0(DL+ EQUP+LL +WIND X)
-5.17 842.582
-15.702
66 1.0(DL+ EQUP+LL -WIND X)
9.316 841.379
-15.637
67 1.0(DL+ EQUP +WIND Z) 0.78 673.942
-10.609
68 1.0(DL+ EQUP -WIND Z) 0.625 691.125
-25.769
69 1.0(DL+ EQUP+LL +WIND Z)2.15 833.389
-8.089
70 1.0(DL+ EQUP+LL -WIND Z)
1.995 850.572
-23.249

96.368
-104.299
-4.198
-3.732
-6.842
-6.376
17.903
-25.833
15.259
-28.477
-20.453
78.92
-119.825
80.344
-118.401
281.392
-322.298
282.817
-320.874
73.384
-114.29
74.809
-112.865
-19.403
-18.654
-22.252
-21.503
0.078
-38.135
-2.771
-40.984
-19.963
87.505
-127.431
89.139
-125.797
309.869
-349.795
311.503
-348.161
82.712
-122.638
84.346
-121.004
-18.424
-18.234
-21.692
-21.502
1.484
-38.142
-1.783
-41.41

7.807
-6.547
2.754
-1.494
3.061
-1.187
1.821
-0.56
2.128
-0.253
0.89
8.789
-7.008
8.559
-7.238
15.875
-14.094
15.645
-14.324
6.316
-4.535
6.086
-4.765
0.295
1.026
0.755
1.485
0.626
0.695
1.085
1.155
0.393
9.346
-8.56
9.288
-8.618
19.521
-18.735
19.463
-18.793
7.006
-6.22
6.948
-6.278
0.5
0.17
0.615
0.286
0.213
0.457
0.328
0.573

108.818
-75.086
32.94
0.793
33.799
1.652
16.582
17.151
17.441
18.01
-5.578
294.631
-305.787
295.876
-304.542
99.88
-111.037
101.126
-109.791
89.007
-100.164
90.253
-98.918
11.582
-20.248
9.091
-22.739
-4.614
-4.051
-7.105
-6.543
-2.707
292.119
-297.532
293.343
-296.309
101.041
-106.455
102.265
-105.231
90.225
-95.639
91.449
-94.415
13.586
-16.553
11.139
-18.999
-1.634
-1.333
-4.08
-3.78

1043 50 1.0(DL+50%LL+EQUP)
8.208 884.838
-18.723
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
136.756 1099.671
39.244
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-120.34 670.005
-76.69
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
136.509 1002.271
37.937
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-120.587 572.605
-77.997
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
53.488 1210.27 153.078
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-37.072 559.406 -190.523
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
53.241 1112.87
151.77
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-37.319 462.006 -191.831
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
48.74 1011.101
35.394
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-32.324 758.575
-72.839
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
48.493 913.701
34.087
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-32.571 661.175
-74.147
63 1.0(DL+ EQUP +WIND X) 1.607 794.452
-20.047
64 1.0(DL+ EQUP -WIND X) 14.315 780.424
-20.013
65 1.0(DL+ EQUP+LL +WIND X)
2.101 989.252
-17.432
66 1.0(DL+ EQUP+LL -WIND 14.809
X)
975.224
-17.399
67 1.0(DL+ EQUP +WIND Z) 8.026 775.636
-9.613
68 1.0(DL+ EQUP -WIND Z) 7.896
799.24
-30.447
69 1.0(DL+ EQUP+LL +WIND Z)
8.521 970.436
-6.998
70 1.0(DL+ EQUP+LL -WIND Z)8.39
994.04
-27.832
1044 50 1.0(DL+50%LL+EQUP)
-0.949 998.783
-0.131
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
116.834
1119.8
65.318
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-118.731 877.765
-65.58
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
116.504 1002.433
63.502
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-119.061 760.398
-67.396
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
40.394 1370.391 203.455
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-42.292 627.174 -203.716
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
40.064 1253.024 201.638
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-42.622 509.807 -205.533
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
36.155 1114.861
63.408
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-38.053 882.704
-63.67
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
35.825 997.494
61.592
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-38.383 765.337
-65.486
63 1.0(DL+ EQUP +WIND X) -7.089 881.253
-1.946
64 1.0(DL+ EQUP -WIND X) 4.531 881.578
-1.948
65 1.0(DL+ EQUP+LL +WIND -6.429
X)
1115.987
1.686
66 1.0(DL+ EQUP+LL -WIND X)
5.191 1116.312
1.685
67 1.0(DL+ EQUP +WIND Z) -1.209 868.411
9.208
68 1.0(DL+ EQUP -WIND Z) -1.348
894.42
-13.102
69 1.0(DL+ EQUP+LL +WIND -0.549
Z)
1103.145
12.84
70 1.0(DL+ EQUP+LL -WIND Z)
-0.689 1129.154
-9.469
1045 50 1.0(DL+50%LL+EQUP)
-0.537 1030.519
-17.047
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
116.178 1151.714
54.801
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-117.251 909.324
-88.895
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
116.478 1034.392
53.08
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-116.951 792.002
-90.616
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
39.604 1398.859 201.367
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-40.677 662.179 -235.461
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
39.904 1281.537 199.646
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-40.377 544.857 -237.182
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
36.039 1145.438
51.158

-22.383
122.244
-167.01
123.784
-165.47
407.524
-452.29
409.064
-450.751
112.77
-157.535
114.309
-155.996
-20.886
-20.8
-23.966
-23.879
3.451
-45.138
0.372
-48.217
-11.695
156.021
-179.411
157.494
-177.939
510.485
-533.875
511.957
-532.402
150.926
-174.315
152.398
-172.843
-10.22
-10.225
-13.165
-13.17
16.244
-36.688
13.299
-39.633
-21.049
157.625
-199.722
159.195
-198.153
522.658
-564.755
524.227
-563.185
148.496

0.207
22.679
-22.266
22.667
-22.278
21.79
-21.376
21.778
-21.388
10.504
-10.09
10.492
-10.102
0.346
0.043
0.37
0.067
-0.009
0.399
0.015
0.423
0
21.631
-21.632
21.619
-21.643
17.016
-17.017
17.004
-17.029
9.048
-9.049
9.036
-9.06
0.236
-0.26
0.26
-0.237
-0.148
0.124
-0.124
0.147
-0.27
22.344
-22.884
22.34
-22.887
15.507
-16.047
15.503
-16.05
8.719

-7.517
278.149
-293.183
279.04
-292.293
92.697
-107.731
93.588
-106.841
82.455
-97.489
83.346
-96.599
7.506
-20.759
5.725
-22.541
-6.761
-6.492
-8.543
-8.274
-0.716
275.47
-276.903
276.142
-276.231
95.639
-97.071
96.311
-96.399
86.146
-87.579
86.818
-86.907
13.269
-13.358
11.925
-14.702
-0.18
0.092
-1.524
-1.252
0.57
275.315
-274.175
275.264
-274.225
95.42
-94.279
95.369
-94.33
86.747

60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-37.112 915.601
-85.252
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
36.339 1028.116
49.437
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-36.813 798.279
-86.973
63 1.0(DL+ EQUP +WIND X) -5.729 913.315
-18.766
64 1.0(DL+ EQUP -WIND X) 5.256
913.08
-18.77
65 1.0(DL+ EQUP+LL +WIND -6.329
X)
1147.958
-15.325
66 1.0(DL+ EQUP+LL -WIND X)
4.656 1147.723
-15.328
67 1.0(DL+ EQUP +WIND Z) -0.15 900.038
-6.835
68 1.0(DL+ EQUP -WIND Z) -0.323 926.357
-30.701
69 1.0(DL+ EQUP+LL +WIND Z)
-0.75 1134.681
-3.393
70 1.0(DL+ EQUP+LL -WIND Z)
-0.923
1161
-27.259
1046 50 1.0(DL+50%LL+EQUP) -12.604 752.844
-17.031
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
128.289 981.139
33.261
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-153.496 524.549
-67.323
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
128.64
908.66
31.789
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-153.144 452.071
-68.796
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
35.49
997.38 120.543
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-60.697 508.309 -154.605
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
35.842 924.901
119.07
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-60.346
435.83 -156.077
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
31.466
862.85
26.89
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-56.673 642.839
-60.952
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
31.817 790.371
25.417
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-56.321
570.36
-62.424
63 1.0(DL+ EQUP +WIND X)-18.805 672.519
-18.447
64 1.0(DL+ EQUP -WIND X)
-5.7 688.212
-18.559
65 1.0(DL+ EQUP+LL +WIND-19.508
X)
817.477
-15.502
66 1.0(DL+ EQUP+LL -WIND X)
-6.402 833.169
-15.614
67 1.0(DL+ EQUP +WIND Z)-12.139 672.061
-9.906
68 1.0(DL+ EQUP -WIND Z) -12.365
688.67
-27.101
69 1.0(DL+ EQUP+LL +WIND-12.842
Z)
817.019
-6.961
70 1.0(DL+ EQUP+LL -WIND-13.068
Z)
833.627
-24.156
1047 50 1.0(DL+50%LL+EQUP)
-6.6 281.799
-21.614
51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
100.182 608.917
11.212
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-113.383
-45.319
-54.44
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
100.869 595.968
11.551
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
-112.696
-58.269
-54.101
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
29.828 479.232
72.785
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-43.028
84.366 -116.012
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
30.514 466.282
73.124
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
-42.342
71.416 -115.674
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
26.797 404.014
9.164
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-39.998 159.584
-52.392
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
27.484 391.065
9.503
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
-39.311 146.634
-52.053
63 1.0(DL+ EQUP +WIND X)-10.807 282.993
-21.308
64 1.0(DL+ EQUP -WIND X) -1.021 254.706
-21.242
65 1.0(DL+ EQUP+LL +WIND -12.18
X)
308.892
-21.986
66 1.0(DL+ EQUP+LL -WIND X)
-2.394 280.605
-21.919
67 1.0(DL+ EQUP +WIND Z) -5.817 262.705
-15.233
68 1.0(DL+ EQUP -WIND Z) -6.011 274.994
-27.317
69 1.0(DL+ EQUP+LL +WIND Z)
-7.19 288.605
-15.911

-190.594
150.066
-189.024
-19.474
-19.484
-22.613
-22.623
8.314
-47.272
5.174
-50.411
-19.308
111.55
-150.167
112.684
-149.033
342.076
-380.692
343.209
-379.558
95.665
-134.282
96.799
-133.148
-18.05
-18.299
-20.318
-20.566
3.135
-39.484
0.868
-41.752
-22.881
63.479
-109.24
65.083
-107.635
235.858
-281.619
237.463
-280.015
59.649
-105.41
61.254
-103.806
-21.249
-21.302
-24.459
-24.512
-5.665
-36.887
-8.874

-9.259
8.716
-9.262
0.031
-0.578
0.037
-0.571
-0.172
-0.375
-0.166
-0.368
-0.508
15.511
-16.528
15.696
-16.342
25.429
-26.446
25.614
-26.26
9.484
-10.501
9.669
-10.316
-0.173
-0.473
-0.544
-0.843
0.58
-1.226
0.21
-1.597
-0.255
13.77
-14.28
14.006
-14.044
21.832
-22.342
22.068
-22.106
8.542
-9.051
8.777
-8.815
0.106
-0.145
-0.365
-0.616
0.957
-0.995
0.486

-85.606
86.696
-85.657
13.395
-12.356
13.497
-12.255
0.365
0.674
0.467
0.775
10.595
302.555
-281.365
302.071
-281.848
110.663
-89.473
110.179
-89.956
102.004
-80.814
101.52
-81.298
23.65
-3.427
24.617
-2.46
9.925
10.297
10.893
11.265
6.593
274.386
-261.199
273.612
-261.973
98.325
-85.139
97.551
-85.912
90.425
-77.239
89.651
-78.012
18.172
-6.533
19.719
-4.986
5.643
5.997
7.189

70 1.0(DL+ EQUP+LL -WIND Z)


-7.384

300.893

-27.995

-40.096

-1.466

7.544

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

10
2.5

kN/m
m

Density of Water =
Depth Of Foundation =

=
145
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 100 x 1.25 + 18 x 2.5
=
170
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
YES
For with Buoyancy:Gross SBC = 100 + 2.5 x (18-10)
=
120
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 100 + 2.5 x (18-10)
=
145
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

500
5.1
5.1
0.75
0.3
0.75
0.6
0
0.5
2.5

N/mm2
m
m
m
m
m
m
m
m

2.175

Wp

2.175
Z

2.25

Lp

F5

COLUMN NO.

C16

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
100
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 100 + 2.5 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

2.25

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 5.1 x 5.1 x 0.75
=
487.69 kN
Buoyant Self wt. of Fdn = (25 - 10) x 5.1 x 5.1 x 0.75
= 292.6125 kN

S.A.G.

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

S.A.G.

Weight of Soil = [(5.1 x 5.1) - (0.6 x 0.75)] x (2.5 - 0.75 ) x 18


=
805.14 kN
Buoyant weight of Soil = [(5.1 x 5.1) - (0.6 x 0.75)] x (2.5 - 0.75 ) x (18-10)
357.84 kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.6 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

(25 - 10) x 0.75 x 0.6 x 0


=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 487.69 + 0 + 805.14


= 1292.83 kN
Weight of Footing + Soil = 292.6125 + 357.84 + 0
with buoyancy
650.4525 kN

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
JOINT
FORCE-X FORCE-Y
1016 50 1.0(DL+50%LL+EQUP)
-6.459
1529.53
F5-C16 51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
182.31
1759.5
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
-195.228 1299.57
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)183.105
1578.59
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY) -194.434 1118.66
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
53.403
1619.05
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
-66.322 1440.02
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)54.198
1438.14
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY) -65.527
1259.11
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
51.797
1623.25
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
-64.715 1435.81
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)52.591
1442.35
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ) -63.92
1254.91
63 1.0(DL+ EQUP +WIND X)
-11.582
1354.4
64 1.0(DL+ EQUP -WIND X)
0.253
1342.86
65 1.0(DL+ EQUP+LL +WIND X)
-13.171 1716.21
66 1.0(DL+ EQUP+LL -WIND X)
-1.337
1704.67
67 1.0(DL+ EQUP +WIND Z)
-5.667
1349.31
68 1.0(DL+ EQUP -WIND Z)
-5.662
1347.94
69 1.0(DL+ EQUP+LL +WIND Z)
-7.257
1711.12
70 1.0(DL+ EQUP+LL -WIND Z)
-7.251
1709.75

kN - m)
FORCE-Z
7.468
98.734
-83.798
96.8
-85.733
260.213
-245.28
258.279
-247.21
88.247
-73.311
86.313
-75.245
5.587
5.481
9.455
9.349
18.148
-7.08
22.016
-3.212

MOM-X
10.992
235.573
-213.59
233.123
-216.04
633.861
-611.878
631.411
-614.328
209.47
-187.487
207.02
-189.937
8.696
8.387
13.596
13.287
38.263
-21.18
43.163
-16.28

MOM-Y
0.079
19.993
-19.84
19.999
-19.83
20.275
-20.12
20.281
-20.11
9.52
-9.362
9.526
-9.356
-0.152
0.321
-0.164
0.31
0.406
-0.237
0.394
-0.248

Check for Maximum and Minimum Pressure at the Base:- With Buoyancy
Area of Footing A = 5.1 x 5.1
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

26.01

m2

1/6 x 5.1 x 5.1 x 5.1


22.109

m3

1/6 x 5.1 x 5.1 x 5.1


22.109

m3

Total Vertical Load P = 1529.531 + 650.4525


= 2179.9835 kN

MOM Z
-7.238
437.476
-451.952
438.577
-450.85
134.046
-148.522
135.148
-147.421
130.496
-144.973
131.598
-143.871
7.898
-20.171
5.694
-22.374
-6.171
-6.102
-8.374
-8.305

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 2179.9835 / (5.1 x 5.1 )


=

83.813

kN/m

Mxx/Zxx = 10.992 / 22.109


Mxx/Zxx =

0.498

kN/m

Mzz/Zzz = 7.238 / 22.109


Mzz/Zzz =

0.328

kN/m

Maxi.Soil Pressure pmax = 83.813 + 0.498 + 0.328


pmax =

84.64

kN/m

<

120

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 83.813 - 0.498 - 0.328
pmin =

82.99

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- With Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
13.17
kN.m
Calculation of Stabilizing Moment
Due to External Load = 1529.531 x 5.1 / 2
=
3900.31 kN.m
Due to wt. of Pedestral = 0 x 2.55
=
0

kN.m

Due to Self Wt. of Fdn = 292.6125 x 2.55


=
746.16 kN.m
Due to Wt. of Soil = 357.84 x 2.55
=
912.5
kN.m
Total Stabilizing moment = 3900.31 + 0 + 746.16 + 912.5
=
5558.97 kN.m
F.O.S. against Overturning = 5558.97 / 13.17
= 422.093 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

9.88

kN

Total Vertical Load = 2179.98 kN


F.O.S. against Sliding = 2179.9835 x 0.5 / 9.88
= 110.33 > 1.5 Hence Safe

S.A.G.

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

S.A.G.

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Mxx/Zxx Mzz/Zzz
Case
Load
1016 50 1.0(DL+50%LL+EQUP)
2179.984 83.81328
0.5
0.33
F5-C16 51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
2409.948 92.65465
10.66
19.79
0
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
1950.021 74.97195
9.67
20.45
0
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
2229.043 85.69944
10.55
19.84
0
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
1769.117 68.01678
9.78
20.4
0
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
2269.499 87.25484
28.67
6.07
0
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
2090.47 80.37176
27.68
6.72
0
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
2088.594 80.29963
28.56
6.12
0
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
1909.565 73.41655
27.79
6.67
0
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
2273.703 87.41647
9.48
5.91
0
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
2086.266 80.21013
8.49
6.56
0
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
2092.798 80.46126
9.37
5.96
0
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
1905.362 73.25496
8.6
6.51
0
63 1.0(DL+
2004.849
EQUP 77.07991
+WIND X)
0.4
0.36
0
64 1.0(DL+
1993.311
EQUP 76.63631
-WIND X)
0.38
0.92
0
65 1.0(DL+
2366.658
EQUP+LL
90.99029
+WIND X) 0.62
0.26
0
66 1.0(DL+
2355.12
EQUP+LL
90.54669
-WIND X) 0.61
1.02
0
67 1.0(DL+
1999.763
EQUP 76.88437
+WIND Z)
1.74
0.28
0
68 1.0(DL+
1998.397
EQUP 76.83185
-WIND Z)
0.96
0.28
0
69 1.0(DL+
2361.572
EQUP+LL
90.79475
+WIND Z) 1.96
0.38
0
70 1.0(DL+
2360.206
EQUP+LL
90.74223
-WIND Z) 0.74
0.38
Joint

pmax

pall

pmin

84.6433
123.105
105.092
116.089
98.1968
121.995
114.772
114.98
107.877
102.806
95.2601
95.7913
88.365
77.8399
77.9363
91.8703
92.1767
78.9044
78.0719
93.1348
91.8622

120
145
145
145
145
145
145
145
145
145
145
145
145
120
120
120
120
120
120
120
120

82.99
62.21
44.86
55.31
37.84
52.52
45.98
45.62
38.96
72.03
65.17
65.14
58.15
76.32
75.34
90.12
88.92
74.87
75.6
88.46
89.63

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 93.13475 kN/m2
pmax = 123.1047 kN/m2
pmin = 77.83991 kN/m2

pmin =

Load
Mxx/Zxx
Mzz/Zzz
1+2+3
1-2+3
P/A (1)
Case
(2)
(3)
1016 50 1.0(DL+50%LL+EQUP)
83.81328
0.5
0.33
84.644 83.644
F5-C16 51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
92.65465 10.66
19.79
123.105 101.785
0
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
74.97195
9.67
20.45
105.092 85.752
0
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
85.69944 10.55
19.84
116.09
94.99
0
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
68.01678
9.78
20.4
98.197 78.637
0
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
87.25484 28.67
6.07
121.995 64.655
0
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
80.37176 27.68
6.72
114.772 59.412
0
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
80.29963 28.56
6.12
114.98
57.86
0
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
73.41655 27.79
6.67
107.877 52.297
0
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
87.41647
9.48
5.91
102.807 83.847
0
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
80.21013
8.49
6.56
95.261 78.281
0
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
80.46126
9.37
5.96
95.792 77.052
0
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
73.25496
8.6
6.51
88.365 71.165
0
63 1.0(DL+
77.07991
EQUP +WIND
0.4 X)
0.36
77.84
77.04
0
64 1.0(DL+
76.63631
EQUP -WIND
0.38X)
0.92
77.937 77.177
0
65 1.0(DL+
90.99029
EQUP+LL0.62
+WIND X) 0.26
91.871 90.631
0
66 1.0(DL+
90.54669
EQUP+LL0.61
-WIND X) 1.02
92.177 90.957
0
67 1.0(DL+
76.88437
EQUP +WIND
1.74Z)
0.28
78.905 75.425
0
68 1.0(DL+
76.83185
EQUP -WIND
0.96Z)
0.28
78.072 76.152
0
69 1.0(DL+
90.79475
EQUP+LL1.96
+WIND Z) 0.38
93.135 89.215
0
70 1.0(DL+
90.74223
EQUP+LL0.74
-WIND Z) 0.38
91.863 90.383
Joint

37.84

kN/m2

1-2-3

1+2-3

82.984
62.205
44.852
55.31
37.837
52.515
45.972
45.62
38.957
72.027
65.161
65.132
58.145
76.32
75.337
90.111
88.917
74.865
75.592
88.455
89.623

83.984
83.525
64.192
76.41
57.397
109.86
101.33
102.74
94.537
90.987
82.141
83.872
75.345
77.12
76.097
91.351
90.137
78.345
77.512
92.375
91.103

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

S.A.G.

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Mxx/Zxx Mzz/Zzz
Case
Load
1016 50 1.0(DL+50%LL+EQUP)
2822.361 108.5106
0.5
0.33
F5-C16 51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
3052.325 117.352
10.66
19.79
0
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
2592.398 99.66928
9.67
20.45
0
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
2871.42 110.3968
10.55
19.84
0
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
2411.494 92.71411
9.78
20.4
0
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
2911.876 111.9522
28.67
6.07
0
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
2732.847 105.0691
27.68
6.72
0
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
2730.971 104.997
28.56
6.12
0
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
2551.942 98.11388
27.79
6.67
0
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
2916.08 112.1138
9.48
5.91
0
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
2728.643 104.9075
8.49
6.56
0
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
2735.175 105.1586
9.37
5.96
0
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
2547.739 97.95229
8.6
6.51
0
63 1.0(DL+
2647.226
EQUP 101.7772
+WIND X)
0.4
0.36
0
64 1.0(DL+
2635.688
EQUP 101.3336
-WIND X)
0.38
0.92
0
65 1.0(DL+
3009.035
EQUP+LL
115.6876
+WIND X) 0.62
0.26
0
66 1.0(DL+
2997.497
EQUP+LL
115.244
-WIND X) 0.61
1.02
0
67 1.0(DL+
2642.14
EQUP 101.5817
+WIND Z)
1.74
0.28
0
68 1.0(DL+
2640.774
EQUP 101.5292
-WIND Z)
0.96
0.28
0
69 1.0(DL+
3003.949
EQUP+LL
115.4921
+WIND Z) 1.96
0.38
0
70 1.0(DL+
3002.583
EQUP+LL
115.4396
-WIND Z) 0.74
0.38
Joint

pmax

pall

pmin

Result

109.341
147.802
129.789
140.787
122.894
146.692
139.469
139.677
132.574
127.504
119.957
120.489
113.062
102.537
102.634
116.568
116.874
103.602
102.769
117.832
116.56

145
170
170
170
170
170
170
170
170
170
170
170
170
145
145
145
145
145
145
145
145

107.69
86.91
69.55
80.01
62.54
77.22
70.67
70.32
63.66
96.73
89.86
89.83
82.85
101.02
100.04
114.81
113.62
99.57
100.29
113.16
114.32

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 117.8321 kN/m2
pmax = 147.802 kN/m2
pmin = 102.5372 kN/m2

Load
Mxx/Zxx
Mzz/Zzz
1+2+3
P/A (1)
Case
(2)
(3)
1016 50 1.0(DL+50%LL+EQUP)
108.5106
0.5
0.33
109.341
F5-C16 51 1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
117.352 10.66
19.79
147.802
0
52 1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
99.66928
9.67
20.45
129.79
0
53 1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
110.3968 10.55
19.84
140.787
0
54 1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
92.71411
9.78
20.4
122.895
0
55 1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
111.9522 28.67
6.07
146.693
0
56 1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
105.0691 27.68
6.72
139.47
0
57 1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
104.997 28.56
6.12
139.677
0
58 1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
98.11388 27.79
6.67
132.574
0
59 1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
112.1138
9.48
5.91
127.504
0
60 1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
104.9075
8.49
6.56
119.958
0
61 1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
105.1586
9.37
5.96
120.489
0
62 1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
97.95229
8.6
6.51
113.063
0
63 1.0(DL+
101.7772
EQUP +WIND
0.4 X)
0.36
102.538
0
64 1.0(DL+
101.3336
EQUP -WIND
0.38X)
0.92
102.634
0
65 1.0(DL+
115.6876
EQUP+LL0.62
+WIND X) 0.26
116.568
0
66 1.0(DL+
115.244
EQUP+LL0.61
-WIND X) 1.02
116.875
0
67 1.0(DL+
101.5817
EQUP +WIND
1.74Z)
0.28
103.602
0
68 1.0(DL+
101.5292
EQUP -WIND
0.96Z)
0.28
102.77
0
69 1.0(DL+
115.4921
EQUP+LL1.96
+WIND Z) 0.38
117.833
0
70 1.0(DL+
115.4396
EQUP+LL0.74
-WIND Z) 0.38
116.56
Joint

pmin =

62.54

kN/m2

1-2+3

1-2-3

1+2-3

108.341
126.482
110.45
119.687
103.335
89.353
84.11
82.557
76.994
108.544
102.978
101.749
95.863
101.738
101.874
115.328
115.655
100.122
100.85
113.913
115.08

107.681
86.902
69.55
80.007
62.535
77.213
70.67
70.317
63.654
96.724
89.858
89.829
82.843
101.018
100.034
114.808
113.615
99.562
100.29
113.153
114.32

108.68
108.22
88.89
101.11
82.095
134.55
126.03
127.44
119.23
115.68
106.84
108.57
100.04
101.82
100.79
116.05
114.84
103.04
102.21
117.07
115.8

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
1016
F5-C16
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70

1.0(DL+50%LL+EQUP)
13.16103 1658.66
3900.31
422.39
1.0(DL+EQUP+50%LL+EQX+0.3EQZ+0.3EQY)
496.8701 1658.66
4486.72
12.37
1.0(DL+EQUP+50%LL-EQX-0.3EQZ-0.3EQY)
499.8813 1658.66
3313.9
9.95
1.0(DL+EQUP+EQX+0.3EQZ+0.3EQY)
496.6851 1658.66
4025.41
11.45
1.0(DL+EQUP-EQX-0.3EQZ-0.3EQY)
499.939 1658.66
2852.6
9.03
1.0(DL+EQUP+50%LL+EQZ+0.3EQX+0.3EQY)
647.8797 1658.66
4128.57
8.94
1.0(DL+EQUP+50%LL-EQZ-0.3EQX-0.3EQY)
629.6455 1658.66
3672.05
8.47
1.0(DL+EQUP+EQZ+0.3EQX+0.3EQY)
645.7127 1658.66
3667.26
8.25
1.0(DL+EQUP-EQZ-0.3EQX-0.3EQY)
631.7688 1658.66
3210.74
7.71
1.0(DL+EQUP+50%LL+EQY+0.3EQX+0.3EQZ)
246.7932 1658.66
4139.29
23.5
1.0(DL+EQUP+50%LL-EQY-0.3EQX-0.3EQZ)
236.999 1658.66
3661.33
22.45
1.0(DL+EQUP+EQY+0.3EQX+0.3EQZ)
245.3066 1658.66
3677.98
21.76
1.0(DL+EQUP-EQY-0.3EQX-0.3EQZ)
238.2749 1658.66
3200.02
20.4
1.0(DL+
11.74729
EQUP +WIND
1658.66
X) 3453.71
435.2
1.0(DL+
21.84516
EQUP -WIND
1658.66
X) 3424.29
232.69
1.0(DL+
14.74018
EQUP+LL
1658.66
+WIND X)
4376.33
409.43
1.0(DL+
26.02192
EQUP+LL
1658.66
-WIND X)
4346.91
230.79
1.0(DL+
38.75743
EQUP +WIND
1658.66
Z) 3440.75
131.58
1.0(DL+
22.04148
EQUP -WIND
1658.66
Z) 3437.26
231.2
1.0(DL+
43.96781
EQUP+LL
1658.66
+WIND Z)
4363.36
136.97
1.0(DL+
18.27598
EQUP+LL
1658.66
-WIND Z)
4359.88
329.32

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
9.873688
207.3291
212.4525
207.1176
212.4964
265.6364
254.0854
263.9043
255.7481
102.3253
97.78821
101.073
98.72982
12.85913
5.486836
16.21334
9.444118
19.01223
9.065575
23.18121
7.93057

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

600
750

mm
mm

5100
5100
675
0.222

mm
mm
mm
%

S.A.G.

Total
FOS for
Result
Vert.
Sliding
Load
2180
2409.9
1950
2229
1769.1
2269.5
2090.5
2088.6
1909.6
2273.7
2086.3
2092.8
1905.4
2004.8
1993.3
2366.7
2355.1
1999.8
1998.4
2361.6
2360.2

110.4
5.82
4.59
5.39
4.17
4.28
4.12
3.96
3.74
11.12
10.67
10.36
9.65
77.96
181.65
72.99
124.69
52.6
110.22
50.94
148.81

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

S.A.G.

Punching Load
Maximum Load on Column = 1759.495 kN
Punching Shear,P =
1759.495 x (( 5.1 x 5.1 ) - ( 1.275 x 1.425 ))
( 5.1 * 5.1 )
P = 1636.59 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
600
750
0.8
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1275
1425
5400

mm
mm
mm

Depth Required 1636590


=
1.37 x5400
= 221.22 mm
Shear Resistance = 1.37 x 5400 x 675 / 1000
4993
kN
147.802

kN/m2

B) One Way Shear


1500
0

2175

136.161

kN/m2

130.923

kN/m2

675

750

5100

750

600
200
2250
675

1575

5100

126.482

kN/m2
138.397 kN/m2

147.802

kN/m2

141.218

kN/m2

108.222

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 141.218 - 25 x 0.75 - 18
90.968 kN/m2
-- For
Length at critical section =
5100
mm
Width at critical section =
1500
mm
Shear Force = 90.968 x 5.1 x 1.5
= 695.9052 kN
At Width
Maximum Pressure = 136.161 - 25 x 0.75 - 18
85.911 kN/m2
-- For
Length at critical section =
5100
mm
Width at critical section =
1575
mm
Shear Force = 85.911 x 5.1 x 1.575
= 690.0801 kN

x ( 2.5 - 0.75 )
without Buoynacy Condition With Stress Increse

x ( 2.5 - 0.75 )
without Buoynacy Condition With Stress Increse

Designed Shear Strength = 695.9052 kN


Corresponding Length =
5100
mm
% Ast =

0.222

Allowable Shear Stress =


0.346
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.346 x 1
2

N/mm
=
0.346
Depth Required = 695905.2
0.346 x 5100
=
470
mm
Check For Depth @ Critical Section
Critical section from face of
column =
675
mm
Min. Length from column face to
edge of footing =
2175
Depth @ Edge of fdn D1 =
300
Depth @ face of column D =
750
Depth @ Critical s/c =
610.35
Effe. Depth @ Critical s/c =
535.35
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 147.802
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 487.69 + 805.14 ) / ( 5.1 x 5.1 )
49.71
98.092 kN/m2
2.25

Bending Moment = 98.092 x 2.25 x 2.25 / 2


= 248.3 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

1311.56
0.17

mm2
%

1147.5
20

mm2
mm dia bars
mm2
mm

314
239
210

1-

(4.6 x Mu )
fck x b x d2

fy
Ast =
Mini.% of re-bar =

S.A.G.

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1495.24

S.A.G.

mm

Provide 20 mm dia Bars @ 210 mm spacing bothways

i.e.0.222%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 1292.83 kN
Area Load = 1292.83 / (5.1 x 5.1)

Maxi. Projection of fdn =

49.71

kN/m2

2.25

Bending Moment = 49.71 x 2.25 x 2.25 / 2


=
Ast =

125.83

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

653.68

Mini % of Re-bar =

0.12

Ast =
Use

810
16

Area of bar =
Spacing =
Provide Spacing =

200.96

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

248
240

mm
mm
2
Area Provided = 837.334 mm
Provide 16 mm dia Bars @ 240 mm spacing bothways

i.e.0.125%

Summary Of Design :Length Of Footing :5100 mm


WIdth Of Footing :5100 mm
Depth Of Footing :750
mm
Depth @ Edge of fdn D1 =
300
mm
Reinforcement :At Top :- Provide 16 mm dia Bars @ 240 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 210 mm spacing bothways

COLUMN SUPPORT REACTION FOR FOOTING DESIGN


Column
Nos.

Node

C18

234

C21

235

C22

236

C23

237

C24

238

L/C
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ

Horizontal Vertical Horizontal


Fx kN
Fy kN
Fz kN
5.347
390.529
-27.713
-67.742
36.236
-22.434
-84.929
40.824
-28.478
-86.967 -113.599 -17.219
76.297
588.61
-21.907
95.12
731.29
-27.819
93.082
576.867
-16.56
4.431
383.044
-76.127
5.287
474.333
-95.594
3.249
319.911
-84.335
4.124
241.802
31.786
4.903
297.781
39.297
2.865
143.358
50.556
2.369
776.811
-80.583
-86.806
627.33
-64.708
-108.562 754.844
-72.978
-109.488 455.847
-43.907
90.597
615.567
-64.226
113.191
740.14
-72.375
112.265 441.143
-43.305
2.387
657.064 -144.529
2.929
792.011 -172.754
2.003
493.014 -143.683
1.404
585.833
15.595
1.701
702.973
27.401
0.775
403.976
56.471
1.491
783.838
-84.172
-86.917
626.349
-67.277
-108.719 753.356
-75.508
-109.286 451.653
-45.274
89.303
627.791
-67.398
111.557 755.158
-75.659
110.989 453.455
-45.426
1.61
665.027 -155.278
1.94
801.703 -185.509
1.373
500
-155.276
0.776
589.113
20.603
0.898
706.811
34.342
0.33
405.108
64.575
1.605
783.187
-83.161
-86.821
626.912
-66.552
-108.573 754.163
-74.648
-109.196 452.679
-44.8
89.389
626.188
-66.506
111.689 753.258
-74.592
111.066 451.774
-44.744
1.603
665.636 -156.258
1.956
802.568 -186.782
1.333
501.084 -156.934
0.966
587.464
23.201
1.159
704.853
37.542
0.536
403.369
67.39
0.122
763.931
-74.036
-88.883
599.683
-59.021
-111.195 721.038
-66.151
-111.207 426.892
-39.587
89.078
622.607
-59.437
111.257 749.693
-66.672
111.244 455.547
-40.108
0.327
650.833 -149.731
0.317
784.976 -179.539
0.305
490.83
-152.974
-0.132
571.457
31.272
-0.256
685.755
46.715
-0.268
391.609
73.28

SUPPORT REACTION

Mx kN-m
-41.793
-33.292
-41.913
-25.077
-33.576
-42.267
-25.431
-213.919
-267.696
-250.86
147.05
183.516
200.352
-235.482
-188.728
-213.62
-128.343
-188.043
-212.764
-127.487
-628.012
-762.725
-677.448
251.241
336.341
421.618
-237.289
-189.643
-213.175
-127.811
-190.02
-213.646
-128.282
-669.856
-813.442
-728.078
290.194
386.621
471.985
-232.219
-185.788
-208.483
-125.096
-185.762
-208.451
-125.064
-677.627
-823.281
-739.894
306.076
406.347
489.734
-210.743
-168.141
-188.499
-112.872
-169.047
-189.632
-114.006
-666.047
-810.882
-735.255
328.859
432.751
508.377

Moment
My kN-m
9.494
17.026
20.244
16.862
-1.836
-3.334
-6.716
28.798
34.959
31.577
-13.608
-18.049
-21.431
4.08
7.996
9.241
7.911
-1.468
-2.589
-3.92
13.109
15.633
14.302
-6.581
-8.981
-10.311
-1.608
3.86
4.885
5.504
-6.434
-7.983
-7.363
1.716
2.204
2.824
-4.289
-5.302
-4.683
-0.042
5.093
6.335
6.364
-5.161
-6.482
-6.453
0.951
1.157
1.187
-1.018
-1.305
-1.275
-8.39
-1.921
-1.555
1.463
-11.504
-13.534
-10.516
-5.413
-5.921
-2.903
-8.011
-9.168
-6.15

Mz kN-m
-7.619
161.922
202.773
205.672
-174.112
-217.269
-214.37
-7.038
-8.427
-5.528
-5.152
-6.07
-3.17
-4.038
183.927
230.034
231.599
-190.387
-237.859
-236.294
-4.354
-5.317
-3.752
-2.107
-2.508
-0.943
-2.978
184.135
230.306
231.442
-188.899
-235.986
-234.85
-3.314
-4.004
-2.868
-1.451
-1.676
-0.54
-3.073
184.12
230.255
231.442
-189.038
-236.193
-235.005
-3.165
-3.851
-2.664
-1.753
-2.087
-0.899
-1.387
186.562
233.352
233.847
-188.781
-235.828
-235.333
-1.597
-1.848
-1.352
-0.622
-0.629
-0.133

Page 30

Column
Nos.

Node

C25

239

C27

241

C28

242

C29

243

C30

244

L/C
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ

Horizontal
Fx kN
11.951
-76.361
-95.411
-100.208
95.484
119.395
114.598
9.725
12.197
7.4
9.397
11.787
6.99
-2.715
-87.084
-108.916
-107.805
82.739
103.363
104.473
-2.284
-2.916
-1.806
-2.06
-2.637
-1.527
0.932
-87.761
-109.587
-110.006
89.252
111.678
111.26
0.513
0.756
0.338
0.977
1.335
0.917
-0.536
-90.597
-113.259
-113.039
89.739
112.161
112.381
-0.516
-0.657
-0.438
-0.342
-0.44
-0.221
7.273
-81.078
-101.1
-104.108
92.714
116.14
113.132
5.636
7.292
4.284
6
7.748
4.74

Vertical Horizontal
Fy kN
Fz kN
919.776
54.265
784.509
43.5
947.04
48.848
592.568
29.353
687.133
43.324
825.32
48.629
470.848
29.133
781.496
-45.726
943.273
-62.684
588.801
-82.179
690.146
132.55
829.086 160.161
474.615 140.665
859.206 -100.962
643.979
-80.443
770.153
-90.501
440.399
-54.137
730.75
-81.097
878.617
-91.318
548.863
-54.954
725.702 -169.192
872.306 -201.436
542.552 -165.073
649.028
7.652
776.464
19.618
446.71
55.982
783.66
-86.503
629.605
-68.349
757.231
-76.801
455.677
-45.654
624.251
-70.057
750.539
-78.936
448.985
-47.788
662.146 -150.494
797.907 -179.482
496.353 -148.335
591.711
12.088
709.863
23.746
408.309
54.893
705.791
-54.579
526.263
-38.808
635.058
-43.03
361.85
-23.39
603.002
-48.519
730.983
-55.169
457.774
-35.529
595.278 -108.363
721.327 -129.974
448.119 -110.335
533.987
21.036
644.714
31.775
371.506
51.415
801.107
-28.281
684.895
-22.293
840.34
-28.518
526.209
-16.945
596.877
-22.956
730.317
-29.347
416.186
-17.774
748.729 -104.028
920.133 -130.687
606.002 -119.114
533.042
58.779
650.524
72.822
336.393
84.395

SUPPORT REACTION

Mx kN-m
42.945
34.458
38.829
23.348
34.254
38.573
23.093
-470.488
-592.354
-607.834
539.2
669.755
654.275
-303.433
-242.457
-274.498
-164.554
-243.035
-275.22
-165.277
-720.91
-872.564
-762.62
235.418
322.846
432.79
-252.127
-199.512
-225.035
-133.926
-203.892
-230.509
-139.4
-643.226
-779.677
-688.568
239.822
324.133
415.241
-157.419
-112.731
-125.355
-68.611
-139.139
-158.365
-101.621
-477.289
-581.053
-524.309
225.419
297.333
354.077
-36.656
-28.341
-35.79
-20.982
-30.308
-38.249
-23.441
-292.789
-366.35
-351.542
234.14
292.311
307.119

Moment
My kN-m
-2.292
3.821
5.01
5.833
-7.488
-9.127
-8.303
0.749
1.17
1.994
-4.417
-5.287
-4.464
-2.212
4.001
5.228
6.022
-7.541
-9.199
-8.405
-7.005
-8.529
-7.735
3.465
4.558
5.352
-6.226
-0.535
-0.254
2.071
-9.427
-11.37
-9.045
-12.52
-15.236
-12.911
2.558
3.612
5.936
-9.901
-3.591
-3.554
0.033
-12.251
-14.378
-10.792
-26.939
-32.738
-29.152
11.097
14.806
18.393
-5.748
3.473
4.912
6.983
-12.671
-15.267
-13.196
-20.36
-24.879
-22.808
11.163
14.524
16.595

Mz kN-m
-14.816
172.475
215.591
221.519
-196.18
-245.227
-239.3
-12.153
-15.193
-9.266
-11.553
-14.443
-8.516
1.975
184.886
231.174
230.357
-181.726
-227.091
-227.908
1.887
2.425
1.609
1.273
1.657
0.841
-2.088
185.728
232.019
232.911
-189.069
-236.478
-235.586
-1.122
-1.544
-0.652
-2.219
-2.915
-2.023
-0.327
189.051
236.302
236.438
-189.574
-236.98
-236.844
0.217
0.258
0.394
-0.739
-0.937
-0.801
-9.168
178.312
222.579
226.371
-192.981
-241.538
-237.746
-6.672
-8.652
-4.86
-7.996
-10.307
-6.515

Page 31

Column
Nos.

Node

C31

245

C20

246

C19

247

C1

248

C2

249

L/C
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ

Horizontal
Fx kN
-15.254
-69.984
-87.635
-81.471
45.577
56.817
62.98
-12.524
-15.81
-9.646
-11.883
-15.009
-8.845
-4.67
-90.148
-112.819
-110.897
82.675
103.21
105.132
-4.081
-5.236
-3.314
-3.391
-4.374
-2.452
12.16
-84.795
-106.089
-110.915
104.251
130.218
125.392
11.152
13.843
9.018
8.305
10.285
5.459
4.757
-68.992
-86.502
-88.3
76.603
95.492
93.694
3.441
4.039
2.241
4.17
4.95
3.152
9.977
-87.342
-109.261
-113.219
103.306
129.049
125.091
7.454
9.234
5.276
8.51
10.554
6.596

Vertical Horizontal
Fy kN
Fz kN
429.716
-12.375
445.801
-10.426
550.41
-13.123
381.26
-8.137
241.745
-9.374
295.34
-11.808
126.19
-6.822
428.924
-53.425
529.314
-66.872
360.164
-61.886
258.622
33.625
316.437
41.941
147.286
46.927
926.934
12.381
717.939
8.314
864.32
6.184
506.788
2.915
765.156
11.496
923.34
10.161
565.808
6.892
826.268
-93.873
999.731
-121.55
642.199 -124.819
656.827 113.683
787.929 137.895
430.397 134.626
725.486
-34.301
755.004
-28.928
921.414
-33.059
640.156
-20.579
405.774
-25.954
484.876
-29.342
203.618
-16.862
609.389
-78.478
739.394
-94.996
458.136
-82.516
551.39
23.595
666.896
32.595
385.638
45.076
469.998
41.548
99.953
33.322
120.39
41.888
-65.789
25.175
652.044
33.155
810.504
41.679
624.325
24.966
303.123
-20.909
374.353
-25.901
188.174
-42.615
448.874
87.386
556.541 109.468
370.362
92.755
737.599
23.992
765.996
23.043
935.274
26.183
649.123
17.635
414.162
15.344
495.48
16.559
209.329
8.011
566.77
-28.412
686.241
-38.136
400.09
-46.685
613.388
66.799
744.513
80.878
458.362
72.33

SUPPORT REACTION

Mx kN-m
-16.896
-14.806
-18.534
-11.765
-12.228
-15.312
-8.543
-147.173
-183.992
-177.223
120.138
150.146
156.916
-32.855
-29.386
-40.131
-25.629
-23.183
-32.377
-17.876
-412.863
-519.477
-504.976
360.294
446.969
461.47
-118.054
-97.089
-111.056
-67.957
-91.797
-104.441
-61.342
-355.933
-434.611
-391.511
167.047
219.114
262.213
36.559
28.717
35.763
21.193
29.777
37.087
22.517
-151.557
-189.58
-204.15
210.051
262.43
247.86
76.942
69.851
77.8
50.829
53.256
57.056
30.085
-198.472
-257.604
-284.575
321.579
392.459
365.488

Moment
My kN-m
0.916
19.297
24.034
23.702
-17.831
-22.376
-22.708
-5.792
-7.327
-7.658
7.257
8.984
8.653
10.489
14.392
16.96
13.176
2.391
1.959
-1.825
18.219
21.744
17.961
-1.437
-2.826
-6.609
-0.081
2.156
2.937
2.873
-2.285
-2.614
-2.679
21.837
27.538
27.474
-21.966
-27.215
-27.28
-7.946
-20.176
-24.31
-21.495
7.463
10.239
13.053
14.112
18.55
21.364
-26.825
-32.621
-29.807
0.98
-1.658
-2.034
-2.442
3.227
4.072
3.664
22.663
28.367
27.96
-21.095
-26.33
-26.738

Mz kN-m
16.486
165.71
207.25
200.611
-139.333
-174.054
-180.693
14.038
17.66
11.021
12.339
15.536
8.897
3.839
187.65
234.785
233.16
-181.508
-226.662
-228.286
2.794
3.716
2.091
3.348
4.407
2.783
-15.328
181.364
226.901
232.954
-205.889
-257.166
-251.113
-14.611
-18.068
-12.015
-9.914
-12.197
-6.144
-6.588
164.198
205.637
208.117
-174.739
-218.035
-215.555
-4.026
-4.643
-2.163
-6.515
-7.755
-5.275
-12.5
185.044
231.494
236.418
-205.044
-256.116
-251.192
-8.642
-10.614
-5.689
-11.358
-14.009
-9.084

Page 32

Column
Nos.

Node

C4

250

C5

251

C6

252

C7

253

C8

254

L/C
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ

Horizontal
Fx kN
1.057
-88.421
-110.587
-110.986
90.113
112.581
112.182
0.458
0.512
0.113
1.234
1.482
1.083
1.15
-87.662
-109.656
-110.084
89.502
111.799
111.37
0.526
0.578
0.15
1.315
1.565
1.136
1.102
-87.618
-109.576
-109.995
89.382
111.674
111.254
0.579
0.671
0.251
1.184
1.427
1.008
0.291
-89.015
-111.365
-111.443
89.48
111.754
111.677
-0.006
-0.104
-0.182
0.471
0.493
0.415
7.058
-81.047
-101.275
-104.112
92.339
115.458
112.621
5.529
6.944
4.108
5.764
7.238
4.402

Vertical Horizontal
Fy kN
Fz kN
779.083
72.685
629.083
59.129
757.016
66.008
457.118
40.096
617.449
57.167
742.474
63.556
442.576
37.643
587.344
-22.041
704.843
-35.454
404.945
-61.367
659.188 138.337
794.648 165.018
494.75
139.105
782.233
82.439
625.103
65.897
751.794
73.774
450.735
44.238
626.47
66.005
753.502
73.908
452.443
44.372
587.821
-21.988
705.19
-36.082
404.131
-65.619
663.752
153.89
800.105 183.765
499.046 154.229
782.687
82.662
626.505
66.164
753.654
74.163
452.37
44.515
625.794
66.096
752.764
74.077
451.48
44.429
587.084
-23.6
704.377
-38.043
403.094
-67.691
665.215
155.86
802.04
186.282
500.757 156.634
766.713
74.043
602.218
59.051
724.21
66.201
428.95
39.629
624.522
59.418
752.089
66.66
456.829
40.088
573.598
-31.185
688.435
-46.594
393.175
-73.166
653.142 149.654
787.865 179.455
492.605 152.882
925.333
-50.983
787.943
-40.731
951.378
-45.404
594.665
-27.214
692.59
-40.842
832.186
-45.542
475.473
-27.353
694.23
-130.033
834.236 -157.031
477.523 -138.842
786.303
48.46
949.328
66.085
592.615
84.274

SUPPORT REACTION

Mx kN-m
195.858
158.847
176.167
106.781
154.526
170.766
101.379
-283.566
-376.848
-446.235
596.938
723.781
654.394
226.142
180.882
202.175
121.289
180.945
202.254
121.368
-299.12
-397.827
-478.713
660.947
802.256
721.37
228.97
183.263
205.318
123.235
183.089
205.1
123.017
-308.672
-409.6
-491.684
675.024
820.019
737.935
210.134
167.748
188.043
112.646
168.467
188.943
113.546
-329.191
-433.13
-508.527
665.406
810.116
734.719
-38.051
-30.214
-33.518
-19.997
-30.668
-34.084
-20.564
-535.517
-665.146
-651.625
474.635
597.544
611.064

Moment
My kN-m
-10.823
-12.93
-15.417
-11.386
-4.388
-4.74
-0.708
1.013
2.012
6.043
-18.331
-22.168
-18.137
-0.371
-5.425
-6.851
-6.675
4.832
5.971
6.147
2.705
3.312
3.488
-3.298
-4.192
-4.016
-0.586
-5.586
-6.954
-6.731
4.648
5.838
6.062
0.522
0.68
0.904
-1.459
-1.796
-1.573
8.143
1.705
1.275
-1.639
11.323
13.298
10.383
7.793
8.885
5.97
5.236
5.688
2.774
2.347
-3.73
-4.841
-5.708
7.485
9.178
8.311
4.719
5.721
4.853
-0.964
-1.383
-2.251

Mz kN-m
-2.209
186.427
233.17
233.999
-189.961
-237.315
-236.486
-0.789
-0.85
-0.021
-2.745
-3.295
-2.466
-2.27
185.555
232.094
232.942
-189.187
-236.334
-235.486
-0.925
-1.007
-0.159
-2.706
-3.233
-2.385
-2.189
185.536
232.035
232.864
-189.038
-236.183
-235.353
-1.067
-1.219
-0.389
-2.435
-2.929
-2.1
-1.257
187.184
234.139
234.578
-189.196
-236.336
-235.897
-0.5
-0.467
-0.027
-1.511
-1.73
-1.291
-8.938
178.236
222.805
226.376
-192.537
-240.662
-237.09
-6.886
-8.598
-5.027
-7.414
-9.259
-5.687

Page 33

Column
Nos.

Node

C10

255

C11

256

C12

257

C13

258

C14

259

L/C
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ

Horizontal Vertical Horizontal


Fx kN
Fy kN
Fz kN
-5.897
1042.138 119.437
-90.826
791.854
94.871
-113.585 954.034 108.327
-111.206 551.492
64.657
81.391
875.566
96.228
101.687 1058.674 110.023
104.066 656.132
66.353
-4.17
756.248
-22.158
-5.266
909.526
-37.959
-2.886
506.984
-81.629
-5.264
911.172 213.256
-6.633
1103.182 256.309
-4.253
700.64
212.639
0.362
782.199
76.938
-88.691
628.007
60.307
-110.75
755.308
67.006
-110.941 454.309
39.582
89.271
623.512
62.794
111.702 749.688
70.115
111.512 448.689
42.69
0.492
591.158
-18.273
0.729
709.246
-31.219
0.539
408.247
-58.643
0.087
660.361 141.374
0.223
795.75
168.34
0.032
494.751 140.916
-1.034
703.314
51.878
-91.688
524.238
36.249
-114.621 632.568
39.895
-114.203 360.334
21.311
90.033
601.065
46.756
112.531 728.602
53.028
112.949 456.368
34.444
-0.837
532.101
-23.21
-1.057
642.397
-34.428
-0.639
370.163
-53.013
-0.818
593.202 106.214
-1.034
718.773 127.352
-0.615
446.539 108.767
7.004
778.523
14.288
-82.068
668.481
11.726
-102.337
819.79
15.359
-105.238 514.705
9.363
93.275
577.156
11.135
116.84
705.634
14.62
113.94
400.549
8.624
5.787
515.961
-69.685
7.481
629.14
-86.405
4.58
324.055
-92.4
5.42
729.676
92.546
7.022
896.284 116.383
4.121
591.199 110.388
-15.427
548.914
32.236
-71.797
543.253
25.138
-89.908
668.07
32.084
-83.672
452.903
18.925
47.113
335.009
26.439
58.73
407.765
33.711
64.966
192.598
20.552
-12.052
404.984
-10.226
-15.227
495.234
-12.121
-8.991
280.067
-25.28
-12.631
473.278
61.804
-15.951
580.601
77.916
-9.715
365.434
64.757

SUPPORT REACTION

Mx kN-m
222.464
175.634
193.54
114.955
180.309
199.384
120.799
-304.89
-407.114
-485.699
660.833
800.039
721.454
203.067
158.916
175.581
103.58
165.992
184.426
112.424
-274.519
-366.213
-438.215
599.427
726.22
654.219
141.846
99.432
109.077
58.424
127.523
144.191
93.538
-237.786
-312.445
-363.099
464.741
565.714
515.06
12.94
11.139
14.395
9.03
9.565
12.427
7.063
-252.735
-315.448
-320.813
273.44
342.27
336.906
33.25
25.866
32.774
19.297
27.334
34.609
21.133
-98.767
-123.017
-136.494
151.967
190.4
176.923

Moment
My kN-m
1.648
-2.866
-3.796
-4.369
5.503
6.665
6.091
-3.411
-4.477
-5.051
6.048
7.347
6.773
-2.343
-6.694
-8.54
-7.534
2.945
3.508
4.514
-7.705
-9.804
-8.798
3.956
4.772
5.778
8.031
2.317
2.015
-0.845
10.533
12.285
9.425
-12.631
-16.67
-19.53
25.48
30.969
28.109
4.239
-7.347
-9.629
-11.147
14.13
17.216
15.699
-12.294
-15.814
-17.331
19.077
23.401
21.883
-0.382
-15.732
-19.635
-19.494
15.121
18.93
19.071
-7.175
-8.94
-8.799
6.564
8.235
8.376

Mz kN-m
5.912
189.695
237.179
234.79
-180.237
-225.236
-227.625
3.996
5.055
2.667
5.462
6.888
4.499
-1.132
187.391
234.1
234.608
-189.202
-236.642
-236.134
-1.353
-1.83
-1.322
-0.458
-0.712
-0.203
0.537
190.966
238.693
238.484
-190.107
-237.649
-237.858
0.13
0.147
-0.062
0.729
0.897
0.688
-8.563
180.207
224.945
228.496
-193.908
-242.699
-239.148
-7.443
-9.618
-6.067
-6.258
-8.137
-4.586
16.952
168.566
210.826
203.998
-141.443
-176.685
-183.513
12.823
16.147
9.319
14.3
17.993
11.165

Page 34

Column
Nos.

Node

C3

261

SC5

262

C16

265

C17

266

SC2

268

L/C
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ

Horizontal
Fx kN
-2.485
-89.198
-111.663
-110.603
85.222
106.361
107.422
-2.528
-3.326
-2.265
-1.448
-1.976
-0.916
-13.055
-27.404
-34.243
-29.026
6.517
8.158
13.375
-10.9
-13.613
-8.396
-9.988
-12.473
-7.255
-4.953
-49.187
-60.974
-59.197
41.262
52.087
53.864
-4.028
-4.527
-2.749
-3.896
-4.361
-2.584
-5.416
-50.293
-62.412
-60.428
41.629
52.49
54.475
-3.971
-4.508
-2.524
-4.694
-5.413
-3.429
4.847
-1.325
-1.662
-3.599
9.08
11.343
9.407
3.127
3.902
1.966
4.629
5.779
3.843

Vertical Horizontal
Fy kN
Fz kN
1101.318 22.874
856.23
17.567
1037.712 26.073
610.215
15.278
905.879
19.031
1099.774 27.904
672.277
17.108
820.608
-68.933
993.185
-82.052
565.688
-92.848
941.501 105.532
1144.301 136.029
716.804 125.234
424.823
-7.985
342.414
-6.434
428.362
-8.105
258.295
-4.886
337.302
-6.342
421.972
-7.99
251.905
-4.771
333.803
-23.616
417.597
-29.582
247.53
-26.363
345.914
10.84
432.737
13.488
262.67
16.707
886.62
13.624
721.265
11.305
856.639
14.122
519.968
8.676
697.326
10.494
826.716
13.107
490.045
7.661
708.258
-99.152
840.38
-123.95
503.709 -129.396
710.333 120.951
842.974 151.179
506.303 145.733
687.282
-19.735
564.591
-15.326
689.666
-19.75
421.182
-11.619
535.06
-16.25
652.752
-20.905
384.268
-12.774
498.774
-72.369
607.394
-91.052
338.91
-82.922
600.878
40.792
735.024
50.398
466.54
58.529
365.362
-3.534
286.426
-2.674
357.931
-3.352
211.826
-1.935
298.154
-2.98
372.591
-3.734
226.487
-2.317
290.986
-26.911
363.631
-33.648
217.526
-32.23
293.594
21.257
366.891
26.562
220.787
27.979

SUPPORT REACTION

Mx kN-m
2.52
0.227
2.982
0.895
3.805
7.455
5.367
-367.795
-457.045
-459.133
371.827
467.482
465.394
-9.759
-7.851
-9.92
-5.974
-7.763
-9.81
-5.864
-37.437
-46.902
-42.956
21.823
27.173
31.118
10.251
9.178
11.492
7.384
7.224
9.049
4.941
-286.997
-358.726
-362.835
303.399
379.267
375.159
-24.914
-19.992
-25.604
-15.393
-19.87
-25.452
-15.241
-168.03
-210.652
-200.44
128.168
159.596
169.807
-4.07
-3.076
-3.853
-2.222
-3.436
-4.303
-2.671
-46.687
-58.367
-56.736
40.175
50.211
51.842

Moment
My kN-m
-5.629
-15.705
-18.936
-16.962
6.699
9.069
11.042
6.019
8.219
10.192
-15.025
-18.086
-16.112
0.174
0.625
0.761
0.7
-0.346
-0.454
-0.515
0.209
0.241
0.179
0.07
0.067
0.005
2.616
7.282
8.869
7.916
-3.097
-4.104
-5.057
-0.645
-1.039
-1.992
4.83
5.804
4.851
-0.314
24.624
30.825
30.933
-25.127
-31.365
-31.257
1.816
2.315
2.423
-2.319
-2.855
-2.747
0.055
0.23
0.29
0.267
-0.142
-0.176
-0.198
0.083
0.106
0.083
0.005
0.008
-0.015

Mz kN-m
1.741
187.366
234.472
233.67
-184.581
-230.462
-231.264
2.627
3.548
2.746
0.158
0.462
-0.34
14.253
43.032
53.773
48.079
-20.228
-25.302
-30.996
12.258
15.304
9.61
10.547
13.166
7.472
16.016
251.212
312.41
306.645
-225.585
-283.586
-289.351
13.037
14.692
8.927
12.589
14.132
8.367
8.636
220.44
274.716
271.595
-206.623
-259.112
-262.233
5.151
5.605
2.484
8.666
9.999
6.879
-7.044
5.918
7.408
10.221
-17.188
-21.475
-18.661
-4.137
-5.16
-2.347
-7.134
-8.907
-6.093

Page 35

Column
Nos.

Node

C15

270

SC6

273

C26

283

C9

285

SC1

363

L/C
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ

Horizontal Vertical Horizontal


Fx kN
Fy kN
Fz kN
5.838
704.052
-11.743
-17.989
555.729
-9.869
-22.384
681.164
-12.452
-24.76
404.942
-7.709
27.33
570.753
-8.92
34.264
699.943
-11.267
31.888
423.722
-6.523
5.07
563.193
-86.271
6.439
690.493 -107.956
4.063
414.272 -103.212
4.272
563.289
67.483
5.441
690.613
84.237
3.065
414.392
88.981
0.173
310.52
-8.69
-9.017
248.444
-7.055
-11.243
312.518
-8.817
-11.323
187.525
-5.342
9.294
248.388
-6.849
11.646
312.449
-8.561
11.565
187.456
-5.085
-0.416
227.083
-29.722
-0.491
285.817
-37.151
-0.571
160.824
-33.676
0.692
269.749
15.818
0.894
339.15
19.773
0.813
214.156
23.249
-10.805
1018.46
-94.431
-89.48
817.644
-75.756
-111.836 983.351
-84.754
-107.52
591.448
-50.958
72.191
811.892
-75.334
90.253
976.162
-84.226
94.569
584.259
-50.43
-8.657
857.6
-170.988
-10.807 1033.297 -203.794
-6.491
641.394 -169.998
-8.632
771.936
19.898
-10.776
926.216
34.814
-6.459
534.313
68.61
1.362
927.076
91.731
-79.957
744.403
73.563
-99.941
891.845
81.884
-100.487 536.478
49.219
82.135
738.919
73.207
102.675
884.99
81.439
102.128 529.623
48.774
0.915
699.148
-23.416
1.149
835.276
-39.34
0.603
479.909
-72.004
1.263
784.174 170.186
1.585
941.559 202.663
1.038
586.192 169.998
2.405
263.282
0.156
-7.746
211.326
0.51
-9.656
264.296
0.483
-10.628
158.928
0.483
11.594
209.925
-0.261
14.519
262.545
-0.48
13.546
157.177
-0.48
2.812
214.607
-10.563
3.542
268.396
-13.358
2.569
163.028
-13.359
1.036
206.645
10.813
1.321
258.444
13.362
0.349
153.076
13.361

SUPPORT REACTION

Mx kN-m
-22.67
-18.713
-23.629
-14.466
-17.559
-22.187
-13.024
-224.04
-280.287
-271.124
187.767
234.471
243.635
-11.428
-9.307
-11.634
-7.063
-8.978
-11.222
-6.651
-45.925
-57.407
-52.835
27.64
34.551
39.122
-274.939
-220.5
-247.351
-148.685
-219.403
-245.981
-147.315
-747.668
-906.312
-807.646
307.765
412.98
511.646
249.697
200.061
221.966
133.332
199.454
221.208
132.573
-329.539
-440.034
-528.669
729.055
883.208
794.573
2.26
2.684
3.028
2.255
0.932
0.839
0.066
-21.669
-27.413
-28.186
25.285
31.28
30.507

Moment
My kN-m
2.644
7.264
9.086
8.026
-3.034
-3.786
-4.846
-4.701
-5.87
-6.93
8.931
11.17
10.11
-0.257
0.872
1.101
1.2
-1.283
-1.592
-1.494
-0.43
-0.525
-0.427
0.018
0.035
0.133
11.155
15.973
19.062
14.962
1.875
1.439
-2.661
7.19
8.083
3.983
10.658
12.418
8.318
-2.118
-8.868
-10.522
-9.9
5.48
7.414
8.035
-4.926
-5.594
-4.972
1.538
2.486
3.108
-0.651
-0.835
-0.966
-0.737
-0.207
-0.182
0.048
-0.815
-0.942
-0.712
-0.227
-0.206
0.023

Mz kN-m
-13.919
162.889
203.535
209.134
-185.16
-231.526
-225.928
-11.992
-15.066
-9.468
-10.279
-12.925
-7.327
-0.613
21.372
26.651
26.922
-22.352
-28.003
-27.733
0.671
0.775
1.046
-1.651
-2.127
-1.857
10.934
187.41
234.269
229.893
-169.915
-212.386
-216.763
8.795
11.002
6.625
8.7
10.882
6.505
-2.414
177.172
221.485
222.442
-181.034
-226.272
-225.315
-1.727
-2.139
-1.182
-2.135
-2.648
-1.691
-3.982
14.105
17.608
19.21
-20.476
-25.619
-24.016
-3.754
-4.716
-3.114
-2.617
-3.295
-1.693

Page 36

Column
Nos.

Node

SC3

364

SC4

368

L/C
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ
5 1.5 (DL+LL)
6 1.2 (DL+LL+EQX)
7 1.5 (DL+EQX)
8 0.9DL+1.5EQX
9 1.2 (DL+LL-EQX)
10 1.5 (DL-EQX)
11 0.9DL-1.5EQX
12 1.2 (DL+LL+EQZ)
13 1.5 (DL+EQZ)
14 0.9DL+1.5EQZ
15 1.2 (DL+LL-EQZ)
16 1.5 (DL-EQZ)
17 0.9DL-1.5EQZ

Horizontal
Fx kN
-6.667
-12.971
-16.218
-13.549
2.303
2.875
5.543
-6.198
-7.752
-5.083
-4.469
-5.591
-2.922
-1.72
-4.874
-6.027
-5.365
2.121
2.717
3.379
-0.406
-0.442
0.22
-2.346
-2.868
-2.206

Vertical Horizontal
Fy kN
Fz kN
202.308
-4.91
164.526
-3.748
205.658
-4.281
124.735
-2.479
159.167
-4.108
198.959
-4.73
118.035
-2.928
162.152
-15.829
202.69
-19.381
121.767
-17.579
161.541
7.973
201.927
10.37
121.004
12.173
128.298
1.503
104.346
1.175
131.41
1.227
79.7
0.723
100.93
1.229
127.14
1.294
75.43
0.79
138.317
-4.593
173.874
-5.982
122.164
-6.487
66.959
6.997
84.676
8.504
32.966
8

SUPPORT REACTION

Mx kN-m
-10.778
-8.234
-9.296
-5.383
-9.011
-10.267
-6.354
-38.582
-47.23
-43.318
21.336
27.667
31.58
5.259
4.113
4.296
2.53
4.301
4.53
2.765
-16.074
-20.939
-22.704
24.488
29.765
27.999

Moment
My kN-m
1.316
1.007
1.123
0.651
1.098
1.237
0.765
1.206
1.372
0.9
0.899
0.988
0.516
0
0
0
0
0
0
0
0
0
0
0
0
0

Mz kN-m
6.233
19.344
24.187
21.691
-9.371
-11.706
-14.202
6.613
8.274
5.778
3.359
4.207
1.711
-0.316
7.504
9.277
9.444
-8.01
-10.116
-9.948
-1.004
-1.359
-1.191
0.498
0.519
0.687

Page 37

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
2.8
3.9
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.575

Wp

1.575
Z

1.15

Lp

F1

COLUMN NO.

C18

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.15

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 2.8 x 3.9 x 0.6
=
163.8
kN
Buoyant Self wt. of Fdn = 0 x 2.8 x 3.9 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(2.8 x 3.9) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
265.734 kN
Buoyant weight of Soil = [(2.8 x 3.9) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 163.8 + 0 + 265.734


=
429.53 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
234
F1-C18

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
5.347
390.529
6 1.2 (DL+LL+EQX)
-67.742
36.236
7 1.5 (DL+EQX)
-84.929
40.824
8 0.9DL+1.5EQX
-86.967
-113.6
9 1.2 (DL+LL-EQX)
76.297
588.61
10 1.5 (DL-EQX)
95.12
731.29
11 0.9DL-1.5EQX
93.082
576.867
12 1.2 (DL+LL+EQZ)
4.431
383.044
13 1.5 (DL+EQZ)
5.287
474.333
14 0.9DL+1.5EQZ
3.249
319.911
15 1.2 (DL+LL-EQZ)
4.124
241.802
16 1.5 (DL-EQZ)
4.903
297.781
17 0.9DL-1.5EQZ
2.865
143.358

kN - m)
FORCE-Z
-27.713
-22.434
-28.478
-17.219
-21.907
-27.819
-16.56
-76.127
-95.594
-84.335
31.786
39.297
50.556

MOM-X
-41.793
-33.292
-41.913
-25.077
-33.576
-42.267
-25.431
-213.919
-267.696
-250.86
147.05
183.516
200.352

MOM-Y
9.494
17.026
20.244
16.862
-1.836
-3.334
-6.716
28.798
34.959
31.577
-13.61
-18.05
-21.43

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 2.8 x 3.9
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

10.92

m2

1/6 x 2.8 x 3.9 x 3.9


7.098

m3

1/6 x 3.9 x 2.8 x 2.8


5.096

m3

Total Vertical Load P = 390.529 + 429.53


= 820.059 kN

MOM Z
-7.619
161.922
202.773
205.672
-174.112
-217.269
-214.37
-7.038
-8.427
-5.528
-5.152
-6.07
-3.17

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 820.059 / (2.8 x 3.9 )


=

75.097

kN/m

Mxx/Zxx = 41.793 / 7.098


Mxx/Zxx =

5.888

kN/m

Mzz/Zzz = 7.619 / 5.096


Mzz/Zzz =

1.496

kN/m

Maxi.Soil Pressure pmax = 75.097 + 5.888 + 1.496


pmax =

82.49

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 75.097 - 5.888 - 1.496
pmin =

67.72

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
42.49
kN.m
Calculation of Stabilizing Moment
Due to External Load = 390.529 x 2.8 / 2
=
546.75 kN.m
Due to wt. of Pedestral = 0 x 1.4
=
0

kN.m

Due to Self Wt. of Fdn = 163.8 x 1.4


=
229.32 kN.m
Due to Wt. of Soil = 265.734 x 1.4
=
372.03 kN.m
Total Stabilizing moment = 546.75 + 0 + 229.32 + 372.03
=
1148.1 kN.m
F.O.S. against Overturning = 1148.1 / 42.49
= 27.0205 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

28.23

kN

Total Vertical Load = 820.059 kN


F.O.S. against Sliding = 820.059 x 0.5 / 28.23
= 14.53
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
234 5 1.5 (DL+LL)
390.529 35.76273
F1-C18 6 1.2 (DL+LL+EQX)
36.236 3.318315
0
7 1.5 (DL+EQX)
40.824 3.738462
0
8 0.9DL+1.5EQX
-113.599 -10.4028
0
9 1.2 (DL+LL-EQX)
588.61 53.90201
0
10 1.5 (DL-EQX)
731.29 66.96795
0
11 0.9DL-1.5EQX
576.867 52.82665
0
12 1.2 (DL+LL+EQZ)
383.044 35.07729
0
13 1.5 (DL+EQZ)
474.333 43.43709
0
14 0.9DL+1.5EQZ
319.911 29.29588
0
15 1.2 (DL+LL-EQZ)
241.802 22.14304
0
16 1.5 (DL-EQZ)
297.781 27.26932
0
17 0.9DL-1.5EQZ
143.358 13.12802
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

5.89
4.7
5.91
3.54
4.74
5.96
3.59
30.14
37.72
35.35
20.72
25.86
28.23

1.5
31.78
39.8
40.36
34.17
42.64
42.07
1.39
1.66
1.09
1.02
1.2
0.63

43.1527
39.7983
49.4485
33.4972
92.812
115.568
98.4866
66.6073
82.8171
65.7359
43.883
54.3293
41.988

140
166
166
166
166
166
166
166
166
166
166
166
166

28.38
-33.17
-41.98
-54.31
15
18.37
7.17
3.55
4.06
-7.15
0.41
0.21
-15.74

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 43.15273 kN/m2
pmax = 115.5679 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
234 5 1.5 (DL+LL)
35.76273
5.89
F1-C18 6 1.2 (DL+LL+EQX)
3.318315
4.7
0
7 1.5 (DL+EQX)
3.738462
5.91
0
8 0.9DL+1.5EQX
-10.4028
3.54
0
9 1.2 (DL+LL-EQX)
53.90201
4.74
0
10 1.5 (DL-EQX)
66.96795
5.96
0
11 0.9DL-1.5EQX
52.82665
3.59
0
12 1.2 (DL+LL+EQZ)
35.07729 30.14
0
13 1.5 (DL+EQZ)
43.43709 37.72
0
14 0.9DL+1.5EQZ
29.29588 35.35
0
15 1.2 (DL+LL-EQZ)
22.14304 20.72
0
16 1.5 (DL-EQZ)
27.26932 25.86
0
17 0.9DL-1.5EQZ
13.12802 28.23
Joint

kN/m2

Mzz/Zzz
(3)
1.5
31.78
39.8
40.36
34.17
42.64
42.07
1.39
1.66
1.09
1.02
1.2
0.63

pmin =

1+2+3

1-2+3

-54.31 kN/m2

1-2-3

43.153 31.373
28.373
39.799 30.399 -33.162
49.449 37.629 -41.972
33.498 26.418 -54.303
92.813 83.333
14.993
115.568 103.648 18.368
98.487 91.307
7.167
66.608
6.328
3.548
82.818
7.378
4.058
65.736 -4.965
-7.145
43.884
2.444
0.404
54.33
2.61
0.21
41.989 -14.472 -15.732

1+2-3
40.153
-23.76
-30.15
-47.22
24.473
30.288
14.347
63.828
79.498
63.556
41.844
51.93
40.729

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
234 5 1.5 (DL+LL)
820.059 75.09698
F1-C18 6 1.2 (DL+LL+EQX)
465.766 42.65256
0
7 1.5 (DL+EQX)
470.354 43.07271
0
8 0.9DL+1.5EQX
315.931 28.93141
0
9 1.2 (DL+LL-EQX)
1018.14 93.23626
0
10 1.5 (DL-EQX)
1160.82 106.3022
0
11 0.9DL-1.5EQX
1006.397 92.1609
0
12 1.2 (DL+LL+EQZ)
812.574 74.41154
0
13 1.5 (DL+EQZ)
903.863 82.77134
0
14 0.9DL+1.5EQZ
749.441 68.63013
0
15 1.2 (DL+LL-EQZ)
671.332 61.47729
0
16 1.5 (DL-EQZ)
727.311 66.60357
0
17 0.9DL-1.5EQZ
572.888 52.46227
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

5.89
4.7
5.91
3.54
4.74
5.96
3.59
30.14
37.72
35.35
20.72
25.86
28.23

1.5
31.78
39.8
40.36
34.17
42.64
42.07
1.39
1.66
1.09
1.02
1.2
0.63

82.487
79.1326
88.7827
72.8314
132.146
154.902
137.821
105.942
122.151
105.07
83.2173
93.6636
81.3223

140
166
166
166
166
166
166
166
166
166
166
166
166

67.71
6.18
-2.64
-14.97
54.33
57.71
46.51
42.89
43.4
32.2
39.74
39.55
23.61

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 82.48698 kN/m2
pmax = 154.9022 kN/m2
pmin =

67.71 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
234 5 1.5 (DL+LL)
75.09698
5.89
F1-C18 6 1.2 (DL+LL+EQX)
42.65256
4.7
0
7 1.5 (DL+EQX)
43.07271
5.91
0
8 0.9DL+1.5EQX
28.93141
3.54
0
9 1.2 (DL+LL-EQX)
93.23626
4.74
0
10 1.5 (DL-EQX)
106.3022
5.96
0
11 0.9DL-1.5EQX
92.1609
3.59
0
12 1.2 (DL+LL+EQZ)
74.41154 30.14
0
13 1.5 (DL+EQZ)
82.77134 37.72
0
14 0.9DL+1.5EQZ
68.63013 35.35
0
15 1.2 (DL+LL-EQZ)
61.47729 20.72
0
16 1.5 (DL-EQZ)
66.60357 25.86
0
17 0.9DL-1.5EQZ
52.46227 28.23
Joint

Mzz/Zzz
(3)
1.5
31.78
39.8
40.36
34.17
42.64
42.07
1.39
1.66
1.09
1.02
1.2
0.63

pmin =

1+2+3

1-2+3

-14.97 kN/m2

1-2-3

1+2-3

82.487 70.707
67.707 79.487
79.133 69.733
6.173
15.573
88.783 76.963
-2.638
9.183
72.832 65.752 -14.969 -7.889
132.147 122.667 54.327 63.807
154.903 142.983 57.703 69.623
137.821 130.641 46.501 53.681
105.942 45.662
42.882 103.16
122.152 46.712
43.392 118.83
105.071 34.371
32.191 102.89
83.218 41.778
39.738 81.178
93.664 41.944
39.544 91.264
81.323 24.863
23.603 80.063

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
234
F1-C18
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
42.48181 601.35
6 1.2 (DL+LL+EQX)
165.3091 601.35
7 1.5 (DL+EQX)
207.0594 601.35
8 0.9DL+1.5EQX
207.1951 601.35
9 1.2 (DL+LL-EQX)
177.3199 601.35
10 1.5 (DL-EQX)
221.3421 601.35
11 0.9DL-1.5EQX
215.8732 601.35
12 1.2 (DL+LL+EQZ)
214.0347 601.35
13 1.5 (DL+EQZ)
267.8286 601.35
14 0.9DL+1.5EQZ
250.9209 601.35
15 1.2 (DL+LL-EQZ)
147.1402 601.35
16 1.5 (DL-EQZ)
183.6164 601.35
17 0.9DL-1.5EQZ
200.3771 601.35

546.75
50.74
57.16
-159.04
824.06
1023.81
807.62
536.27
664.07
447.88
338.53
416.9
200.71

27.03
3.95
3.19
2.14
8.04
7.35
6.53
5.32
4.73
4.19
6.39
5.55
4.01

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
28.22412
71.36009
89.5764
88.65525
79.37978
99.10455
94.5436
76.25584
95.74009
84.39756
32.05241
39.60169
50.63711

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

2800
3900
525
0.225

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
820.06
465.77
470.35
315.93
1018.1
1160.8
1006.4
812.57
903.86
749.44
671.33
727.31
572.89

14.53
3.27
2.63
1.79
6.42
5.86
5.33
5.33
4.73
4.44
10.48
9.19
5.66

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column =
731.29 kN
Punching Shear,P =
731.29 x (( 2.8 x 3.9 ) - ( 1.025 x 1.275 ))
( 2.8 * 3.9 )
P = 643.78 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 643780


=
1.37 x4600
= 102.15 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
154.903

kN/m2

B) One Way Shear


1050
0

1575

131.943

kN/m2

120.463

kN/m2

525

600

3900

750

500
200
1150
525

625

2800

142.983

kN/m2
150.008 kN/m2

154.903

kN/m2

152.243

kN/m2

69.623

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 152.243 - 25 x 0.6 - 18 x ( 2 112.043 kN/m2
-- For without
Length at critical section =
2800
mm
Width at critical section =
1050
mm
Shear Force = 112.043 x 2.8 x 1.05
= 329.4064 kN
At Width
Maximum Pressure = 131.943 - 25 x 0.6 - 18 x ( 2 91.743 kN/m2
-- For without
Length at critical section =
3900
mm
Width at critical section =
625
mm
Shear Force = 91.743 x 3.9 x 0.625
= 223.6236 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 329.40642 kN


Corresponding Length =
2800
mm
% Ast =

0.225

Allowable Shear Stress =


0.346
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.346 x 1
2

N/mm
=
0.346
Depth Required = 329406.42
0.346 x 2800
=
416
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1150
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
417.4
Effe. Depth @ Critical s/c =
342.4
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 154.903
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Revise

Bottom
-- Without Buoyancy Load Case
( 163.8 + 265.734 ) / ( 2.8 x 3.9 )
39.33
115.573 kN/m2
1.575

Bending Moment = 115.573 x 1.575 x 1.575 / 2


= 143.35 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

1171.09
0.2
1050
16
200.96
171
170

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1182.12

mm

Provide 16 mm dia Bars @ 170 mm spacing bothways

i.e.0.226%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 429.534 kN
Area Load = 429.534 / (2.8 x 3.9)

Maxi. Projection of fdn =

39.33

kN/m2

1.575

Bending Moment = 39.33 x 1.575 x 1.575 / 2


=
Ast =

48.78

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

390.22

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :2800 mm


WIdth Of Footing :3900 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 170 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
2.75
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.125

Lp

F1

COLUMN NO.

C19

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.125

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 2.75 x 4.6 x 0.6
=
189.75 kN
Buoyant Self wt. of Fdn = 0 x 2.75 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(2.75 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
309.33 kN
Buoyant weight of Soil = [(2.75 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 189.75 + 0 + 309.33


=
499.08 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
247
F1-C19

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
12.16
725.486
6 1.2 (DL+LL+EQX)
-84.795 755.004
7 1.5 (DL+EQX)
-106.089 921.414
8 0.9DL+1.5EQX
-110.915 640.156
9 1.2 (DL+LL-EQX)
104.251 405.774
10 1.5 (DL-EQX)
130.218 484.876
11 0.9DL-1.5EQX
125.392 203.618
12 1.2 (DL+LL+EQZ)
11.152
609.389
13 1.5 (DL+EQZ)
13.843
739.394
14 0.9DL+1.5EQZ
9.018
458.136
15 1.2 (DL+LL-EQZ)
8.305
551.39
16 1.5 (DL-EQZ)
10.285
666.896
17 0.9DL-1.5EQZ
5.459
385.638

kN - m)
FORCE-Z
-34.301
-28.928
-33.059
-20.579
-25.954
-29.342
-16.862
-78.478
-94.996
-82.516
23.595
32.595
45.076

MOM-X
-118.054
-97.089
-111.056
-67.957
-91.797
-104.441
-61.342
-355.933
-434.611
-391.511
167.047
219.114
262.213

MOM-Y
-0.081
2.156
2.937
2.873
-2.285
-2.614
-2.679
21.837
27.538
27.474
-21.97
-27.22
-27.28

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 2.75 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

12.65

m2

1/6 x 2.75 x 4.6 x 4.6


9.699

m3

1/6 x 4.6 x 2.75 x 2.75


5.798

m3

Total Vertical Load P = 725.486 + 499.08


= 1224.566 kN

MOM Z
-15.328
181.364
226.901
232.954
-205.889
-257.166
-251.113
-14.611
-18.068
-12.015
-9.914
-12.197
-6.144

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1224.566 / (2.75 x 4.6 )


=

96.804

kN/m

Mxx/Zxx = 118.054 / 9.699


Mxx/Zxx =

12.172

kN/m

Mzz/Zzz = 15.328 / 5.798


Mzz/Zzz =

2.644

kN/m

Maxi.Soil Pressure pmax = 96.804 + 12.172 + 2.644


pmax =

111.62

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 96.804 - 12.172 - 2.644
pmin =

81.99

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
119.05 kN.m
Calculation of Stabilizing Moment
Due to External Load = 725.486 x 2.75 / 2
=
997.55 kN.m
Due to wt. of Pedestral = 0 x 1.375
=
0
kN.m
Due to Self Wt. of Fdn = 189.75 x 1.375
=
260.91 kN.m
Due to Wt. of Soil = 309.33 x 1.375
=
425.33 kN.m
Total Stabilizing moment = 997.55 + 0 + 260.91 + 425.33
=
1683.79 kN.m
F.O.S. against Overturning = 1683.79 / 119.05
= 14.1436 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

36.4

kN

Total Vertical Load = 1224.57 kN


F.O.S. against Sliding = 1224.566 x 0.5 / 36.4
= 16.83
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
247 5 1.5 (DL+LL)
725.486 57.35067
F1-C19 6 1.2 (DL+LL+EQX)
755.004 59.68411
0
7 1.5 (DL+EQX)
921.414 72.83905
0
8 0.9DL+1.5EQX
640.156 50.60522
0
9 1.2 (DL+LL-EQX)
405.774 32.077
0
10 1.5 (DL-EQX)
484.876 38.33012
0
11 0.9DL-1.5EQX
203.618 16.09628
0
12 1.2 (DL+LL+EQZ)
609.389 48.17304
0
13 1.5 (DL+EQZ)
739.394 58.45012
0
14 0.9DL+1.5EQZ
458.136 36.21628
0
15 1.2 (DL+LL-EQZ)
551.39 43.58814
0
16 1.5 (DL-EQZ)
666.896 52.71905
0
17 0.9DL-1.5EQZ
385.638 30.48522
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

12.18
10.02
11.46
7.01
9.47
10.77
6.33
36.7
44.81
40.37
17.23
22.6
27.04

2.65
31.29
39.14
40.18
35.52
44.36
43.32
2.53
3.12
2.08
1.71
2.11
1.06

72.1807
100.994
123.439
97.7952
77.067
93.4601
65.7463
87.403
106.38
78.6663
62.5281
77.4291
58.5852

140
166
166
166
166
166
166
166
166
166
166
166
166

42.53
18.38
22.24
3.42
-12.92
-16.8
-33.56
8.95
10.53
-6.24
24.65
28.01
2.39

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 72.18067 kN/m2
pmax = 123.4391 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
247 5 1.5 (DL+LL)
57.35067 12.18
F1-C19 6 1.2 (DL+LL+EQX)
59.68411 10.02
0
7 1.5 (DL+EQX)
72.83905 11.46
0
8 0.9DL+1.5EQX
50.60522
7.01
0
9 1.2 (DL+LL-EQX)
32.077
9.47
0
10 1.5 (DL-EQX)
38.33012 10.77
0
11 0.9DL-1.5EQX
16.09628
6.33
0
12 1.2 (DL+LL+EQZ)
48.17304
36.7
0
13 1.5 (DL+EQZ)
58.45012 44.81
0
14 0.9DL+1.5EQZ
36.21628 40.37
0
15 1.2 (DL+LL-EQZ)
43.58814 17.23
0
16 1.5 (DL-EQZ)
52.71905
22.6
0
17 0.9DL-1.5EQZ
30.48522 27.04
Joint

kN/m2

Mzz/Zzz
(3)
2.65
31.29
39.14
40.18
35.52
44.36
43.32
2.53
3.12
2.08
1.71
2.11
1.06

pmin =

-33.56 kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

72.181
100.995
123.44
97.796
77.067
93.461
65.747
87.404
106.381
78.667
62.529
77.43
58.586

47.821
80.955
100.52
83.776
58.127
71.921
53.087
14.004
16.761
-2.074
28.069
32.23
4.506

42.521
18.375
22.24
3.416
-12.914
-16.8
-33.554
8.944
10.521
-6.234
24.649
28.01
2.386

66.881
38.415
45.16
17.436
6.027
4.741
-20.89
82.344
100.14
74.507
59.109
73.21
56.466

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
247 5 1.5 (DL+LL)
1224.566 96.80364
F1-C19 6 1.2 (DL+LL+EQX)
1254.084 99.13708
0
7 1.5 (DL+EQX)
1420.494 112.292
0
8 0.9DL+1.5EQX
1139.236 90.05818
0
9 1.2 (DL+LL-EQX)
904.854 71.52996
0
10 1.5 (DL-EQX)
983.956 77.78308
0
11 0.9DL-1.5EQX
702.698 55.54925
0
12 1.2 (DL+LL+EQZ)
1108.469 87.62601
0
13 1.5 (DL+EQZ)
1238.474 97.90308
0
14 0.9DL+1.5EQZ
957.216 75.66925
0
15 1.2 (DL+LL-EQZ)
1050.47 83.04111
0
16 1.5 (DL-EQZ)
1165.976 92.17202
0
17 0.9DL-1.5EQZ
884.718 69.93818
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

12.18
10.02
11.46
7.01
9.47
10.77
6.33
36.7
44.81
40.37
17.23
22.6
27.04

2.65
31.29
39.14
40.18
35.52
44.36
43.32
2.53
3.12
2.08
1.71
2.11
1.06

111.634
140.447
162.892
137.248
116.52
132.913
105.199
126.856
145.833
118.119
101.981
116.882
98.0382

140
166
166
166
166
166
166
166
166
166
166
166
166

81.98
57.83
61.7
42.87
26.54
22.66
5.9
48.4
49.98
33.22
64.11
67.47
41.84

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 111.6336 kN/m2
pmax = 162.892 kN/m2
pmin =

81.98 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
247 5 1.5 (DL+LL)
96.80364 12.18
F1-C19 6 1.2 (DL+LL+EQX)
99.13708 10.02
0
7 1.5 (DL+EQX)
112.292 11.46
0
8 0.9DL+1.5EQX
90.05818
7.01
0
9 1.2 (DL+LL-EQX)
71.52996
9.47
0
10 1.5 (DL-EQX)
77.78308 10.77
0
11 0.9DL-1.5EQX
55.54925
6.33
0
12 1.2 (DL+LL+EQZ)
87.62601
36.7
0
13 1.5 (DL+EQZ)
97.90308 44.81
0
14 0.9DL+1.5EQZ
75.66925 40.37
0
15 1.2 (DL+LL-EQZ)
83.04111 17.23
0
16 1.5 (DL-EQZ)
92.17202
22.6
0
17 0.9DL-1.5EQZ
69.93818 27.04
Joint

Mzz/Zzz
(3)
2.65
31.29
39.14
40.18
35.52
44.36
43.32
2.53
3.12
2.08
1.71
2.11
1.06

pmin =

5.9

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

111.634
140.448
162.893
137.249
116.52
132.914
105.2
126.857
145.834
118.12
101.982
116.883
98.039

87.274
120.408
139.973
123.229
97.58
111.374
92.54
53.457
56.214
37.38
67.522
71.683
43.959

81.974
57.828
61.693
42.869
26.54
22.654
5.9
48.397
49.974
33.22
64.102
67.463
41.839

106.33
77.868
84.613
56.889
45.48
44.194
18.56
121.8
139.59
113.96
98.562
112.66
95.919

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
247
F1-C19
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
119.0449 686.24
6 1.2 (DL+LL+EQX)
205.7162 686.24
7 1.5 (DL+EQX)
252.6213 686.24
8 0.9DL+1.5EQX
242.6638 686.24
9 1.2 (DL+LL-EQX)
225.4262 686.24
10 1.5 (DL-EQX)
277.5649 686.24
11 0.9DL-1.5EQX
258.4968 686.24
12 1.2 (DL+LL+EQZ)
356.2328 686.24
13 1.5 (DL+EQZ)
434.9864 686.24
14 0.9DL+1.5EQZ
391.6953 686.24
15 1.2 (DL+LL-EQZ)
167.3409 686.24
16 1.5 (DL-EQZ)
219.4532 686.24
17 0.9DL-1.5EQZ
262.285 686.24

997.55
1038.14
1266.95
880.22
557.94
666.71
279.98
837.91
1016.67
629.94
758.17
916.99
530.26

14.15
8.39
7.74
6.46
5.52
4.88
3.74
4.28
3.92
3.37
8.64
7.31
4.64

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
36.39264
89.59364
111.1205
112.8079
107.4331
133.4829
126.5207
79.26641
95.99932
83.00732
25.01394
34.17916
45.40536

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

2750
4600
525
0.598

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1224.6
1254.1
1420.5
1139.2
904.85
983.96
702.7
1108.5
1238.5
957.22
1050.5
1166
884.72

16.83
7
6.4
5.05
4.22
3.69
2.78
7
6.46
5.77
21
17.06
9.75

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 921.414 kN
Punching Shear,P =
921.414 x (( 2.75 x 4.6 ) - ( 1.025 x 1.275 ))
( 2.75 * 4.6 )
P = 826.23 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 826230


=
1.37 x4600
= 131.11 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
162.893

kN/m2

B) One Way Shear


1400
0

1925

139.069

kN/m2

130.135

kN/m2

525

600

4600

750

500
200
1125
525

600

2750

139.973

kN/m2
153.517 kN/m2

162.893

kN/m2

157.893

kN/m2

84.613

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 157.893 - 25 x 0.6 - 18 x ( 2 117.693 kN/m2
-- For without
Length at critical section =
2750
mm
Width at critical section =
1400
mm
Shear Force = 117.693 x 2.75 x 1.4
= 453.1181 kN
At Width
Maximum Pressure = 139.069 - 25 x 0.6 - 18 x ( 2 98.869 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
600
mm
Shear Force = 98.869 x 4.6 x 0.6
= 272.8784 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 453.11805 kN


Corresponding Length =
2750
mm
% Ast =
Allowable Shear Stress =
k =
Case =
Increaae In Shear Stress =
tc =

0.598
0.495968 N/mm2
----Refer Table 19 of IS 456
1
---- Refer clause no. 40.2 of IS 456
Without Stress Increase
Not Allowed
1 x 0.495968 x 1
2

= 0.495968 N/mm
Depth Required = 453118.05
0.495968 x 2750
=
408
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1125
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
413.34
Effe. Depth @ Critical s/c =
338.34
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 162.893
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Revise

Bottom
-- Without Buoyancy Load Case
( 189.75 + 309.33 ) / ( 2.75 x 4.6 )
39.45
123.443 kN/m2
1.925

Bending Moment = 123.443 x 1.925 x 1.925 / 2


= 228.72 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1906.65
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
164
100

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

3140

mm

Provide 20 mm dia Bars @ 100 mm spacing bothways

i.e.0.599%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
499.08 kN
Area Load = 499.08 / (2.75 x 4.6)

Maxi. Projection of fdn =

39.45

kN/m2

1.925

Bending Moment = 39.45 x 1.925 x 1.925 / 2


=
Ast =

73.09

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

587.79

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :2750 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 100 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C20

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
246
F3-C20

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-4.67
926.934
6 1.2 (DL+LL+EQX)
-90.148 717.939
7 1.5 (DL+EQX)
-112.819 864.32
8 0.9DL+1.5EQX
-110.897 506.788
9 1.2 (DL+LL-EQX)
82.675
765.156
10 1.5 (DL-EQX)
103.21
923.34
11 0.9DL-1.5EQX
105.132 565.808
12 1.2 (DL+LL+EQZ)
-4.081
826.268
13 1.5 (DL+EQZ)
-5.236
999.731
14 0.9DL+1.5EQZ
-3.314
642.199
15 1.2 (DL+LL-EQZ)
-3.391
656.827
16 1.5 (DL-EQZ)
-4.374
787.929
17 0.9DL-1.5EQZ
-2.452
430.397

kN - m)
FORCE-Z
12.381
8.314
6.184
2.915
11.496
10.161
6.892
-93.873
-121.55
-124.82
113.683
137.895
134.626

MOM-X
-32.855
-29.386
-40.131
-25.629
-23.183
-32.377
-17.876
-412.863
-519.477
-504.976
360.294
446.969
461.47

MOM-Y
10.489
14.392
16.96
13.176
2.391
1.959
-1.825
18.219
21.744
17.961
-1.437
-2.826
-6.609

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 926.934 + 600.79


= 1527.724 kN

MOM Z
3.839
187.65
234.785
233.16
-181.508
-226.662
-228.286
2.794
3.716
2.091
3.348
4.407
2.783

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1527.724 / (3.3 x 4.6 )


=

100.641

kN/m

Mxx/Zxx = 32.855 / 11.638


Mxx/Zxx =

2.824

kN/m

Mzz/Zzz = 3.839 / 8.349


Mzz/Zzz =

0.460

kN/m

Maxi.Soil Pressure pmax = 100.641 + 2.824 + 0.46


pmax =

103.93

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 100.641 - 2.824 - 0.46
pmin =

97.36

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
33.08
kN.m
Calculation of Stabilizing Moment
Due to External Load = 926.934 x 3.3 / 2
=
1529.45 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1529.45 + 0 + 375.71 + 615.6
=
2520.76 kN.m
F.O.S. against Overturning = 2520.76 / 33.08
= 76.2019 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

13.24

kN

Total Vertical Load = 1527.72 kN


F.O.S. against Sliding = 1527.724 x 0.5 / 13.24
=
57.7
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
246 5 1.5 (DL+LL)
926.934 61.06285
F3-C20 6 1.2 (DL+LL+EQX)
717.939 47.29506
0
7 1.5 (DL+EQX)
864.32 56.93808
0
8 0.9DL+1.5EQX
506.788 33.38524
0
9 1.2 (DL+LL-EQX)
765.156 50.40553
0
10 1.5 (DL-EQX)
923.34 60.82609
0
11 0.9DL-1.5EQX
565.808 37.27325
0
12 1.2 (DL+LL+EQZ)
826.268 54.43136
0
13 1.5 (DL+EQZ)
999.731 65.85843
0
14 0.9DL+1.5EQZ
642.199 42.3056
0
15 1.2 (DL+LL-EQZ)
656.827 43.26924
0
16 1.5 (DL-EQZ)
787.929 51.90573
0
17 0.9DL-1.5EQZ
430.397 28.3529
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

2.83
2.53
3.45
2.21
2
2.79
1.54
35.48
44.64
43.4
30.96
38.41
39.66

0.46
22.48
28.13
27.93
21.75
27.15
27.35
0.34
0.45
0.26
0.41
0.53
0.34

64.3528
72.3051
88.5181
63.5252
74.1555
90.7661
66.1633
90.2514
110.948
85.9656
74.6392
90.8457
68.3529

140
166
166
166
166
166
166
166
166
166
166
166
166

57.78
22.29
25.36
3.25
26.66
30.89
8.39
18.62
20.77
-1.36
11.9
12.97
-11.65

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 64.35285 kN/m2
pmax = 110.9484 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
246 5 1.5 (DL+LL)
61.06285
2.83
F3-C20 6 1.2 (DL+LL+EQX)
47.29506
2.53
0
7 1.5 (DL+EQX)
56.93808
3.45
0
8 0.9DL+1.5EQX
33.38524
2.21
0
9 1.2 (DL+LL-EQX)
50.40553
2
0
10 1.5 (DL-EQX)
60.82609
2.79
0
11 0.9DL-1.5EQX
37.27325
1.54
0
12 1.2 (DL+LL+EQZ)
54.43136 35.48
0
13 1.5 (DL+EQZ)
65.85843 44.64
0
14 0.9DL+1.5EQZ
42.3056
43.4
0
15 1.2 (DL+LL-EQZ)
43.26924 30.96
0
16 1.5 (DL-EQZ)
51.90573 38.41
0
17 0.9DL-1.5EQZ
28.3529 39.66
Joint

kN/m2

Mzz/Zzz
(3)
0.46
22.48
28.13
27.93
21.75
27.15
27.35
0.34
0.45
0.26
0.41
0.53
0.34

pmin =

1+2+3

1-2+3

-11.65 kN/m2

1-2-3

64.353 58.693
57.773
72.306 67.246
22.286
88.519 81.619
25.359
63.526 59.106
3.246
74.156 70.156
26.656
90.767 85.187
30.887
66.164 63.084
8.384
90.252 19.292
18.612
110.949 21.669
20.769
85.966 -0.835
-1.355
74.64
12.72
11.9
90.846 14.026
12.966
68.353 -10.968 -11.648

1+2-3
63.433
27.346
32.259
7.666
30.656
36.467
11.464
89.572
110.05
85.446
73.82
89.786
67.673

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
246 5 1.5 (DL+LL)
1527.724 100.6406
F3-C20 6 1.2 (DL+LL+EQX)
1318.729 86.87279
0
7 1.5 (DL+EQX)
1465.11 96.51581
0
8 0.9DL+1.5EQX
1107.578 72.96298
0
9 1.2 (DL+LL-EQX)
1365.946 89.98327
0
10 1.5 (DL-EQX)
1524.13 100.4038
0
11 0.9DL-1.5EQX
1166.598 76.85099
0
12 1.2 (DL+LL+EQZ)
1427.058 94.00909
0
13 1.5 (DL+EQZ)
1600.521 105.4362
0
14 0.9DL+1.5EQZ
1242.989 81.88333
0
15 1.2 (DL+LL-EQZ)
1257.617 82.84697
0
16 1.5 (DL-EQZ)
1388.719 91.48347
0
17 0.9DL-1.5EQZ
1031.187 67.93063
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

2.83
2.53
3.45
2.21
2
2.79
1.54
35.48
44.64
43.4
30.96
38.41
39.66

0.46
22.48
28.13
27.93
21.75
27.15
27.35
0.34
0.45
0.26
0.41
0.53
0.34

103.931
111.883
128.096
103.103
113.733
130.344
105.741
129.829
150.526
125.543
114.217
130.423
107.931

140
166
166
166
166
166
166
166
166
166
166
166
166

97.36
61.87
64.94
42.83
66.24
70.47
47.97
58.19
60.35
38.23
51.48
52.55
27.94

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 103.9306 kN/m2
pmax = 150.5262 kN/m2
pmin =

97.36 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
246 5 1.5 (DL+LL)
100.6406
2.83
F3-C20 6 1.2 (DL+LL+EQX)
86.87279
2.53
0
7 1.5 (DL+EQX)
96.51581
3.45
0
8 0.9DL+1.5EQX
72.96298
2.21
0
9 1.2 (DL+LL-EQX)
89.98327
2
0
10 1.5 (DL-EQX)
100.4038
2.79
0
11 0.9DL-1.5EQX
76.85099
1.54
0
12 1.2 (DL+LL+EQZ)
94.00909 35.48
0
13 1.5 (DL+EQZ)
105.4362 44.64
0
14 0.9DL+1.5EQZ
81.88333
43.4
0
15 1.2 (DL+LL-EQZ)
82.84697 30.96
0
16 1.5 (DL-EQZ)
91.48347 38.41
0
17 0.9DL-1.5EQZ
67.93063 39.66
Joint

Mzz/Zzz
(3)
0.46
22.48
28.13
27.93
21.75
27.15
27.35
0.34
0.45
0.26
0.41
0.53
0.34

pmin =

27.94

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

103.931
111.883
128.096
103.103
113.734
130.344
105.741
129.83
150.527
125.544
114.217
130.424
107.931

98.271
106.823
121.196
98.683
109.734
124.764
102.661
58.87
61.247
38.744
52.297
53.604
28.611

97.351
61.863
64.936
42.823
66.234
70.464
47.961
58.19
60.347
38.224
51.477
52.544
27.931

103.01
66.923
71.836
47.243
70.234
76.044
51.041
129.15
149.63
125.02
113.4
129.36
107.25

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
246
F3-C20
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
33.07853 991.31
6 1.2 (DL+LL+EQX)
189.937 991.31
7 1.5 (DL+EQX)
238.19
991.31
8 0.9DL+1.5EQX
234.5643 991.31
9 1.2 (DL+LL-EQX)
182.9825 991.31
10 1.5 (DL-EQX)
228.9627 991.31
11 0.9DL-1.5EQX
228.9848 991.31
12 1.2 (DL+LL+EQZ)
412.8725 991.31
13 1.5 (DL+EQZ)
519.4903 991.31
14 0.9DL+1.5EQZ
504.9803 991.31
15 1.2 (DL+LL-EQZ)
360.3096 991.31
16 1.5 (DL-EQZ)
446.9907 991.31
17 0.9DL-1.5EQZ
461.4784 991.31

1529.45
1184.6
1426.13
836.21
1262.51
1523.52
933.59
1363.35
1649.56
1059.63
1083.77
1300.09
710.16

76.21
11.46
10.15
7.8
12.32
10.99
8.41
5.71
5.09
4.07
5.76
5.13
3.69

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
13.23246
90.53057
112.9884
110.9353
83.47044
103.709
105.3577
93.96167
121.6627
124.863
113.7336
137.9644
134.6483

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.332

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1527.7
1318.7
1465.1
1107.6
1365.9
1524.1
1166.6
1427.1
1600.5
1243
1257.6
1388.7
1031.2

57.73
7.29
6.49
5
8.19
7.35
5.54
7.6
6.58
4.98
5.53
5.04
3.83

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 999.731 kN
Punching Shear,P =
999.731 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 913.67 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 913670


=
1.37 x4600
= 144.98 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
150.527

kN/m2

B) One Way Shear


1400
0

1925

150.254

kN/m2

150.151

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

61.247

kN/m2
112.651 kN/m2

150.527

kN/m2

126.855

kN/m2

149.627

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 126.855 - 25 x 0.6 - 18 x ( 2 86.655 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 86.655 x 3.3 x 1.4
= 400.3461 kN
At Width
Maximum Pressure = 150.254 - 25 x 0.6 - 18 x ( 2 110.054 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 110.054 x 4.6 x 0.875
= 442.9674 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 442.96735 kN


Corresponding Length =
4600
mm
% Ast =

0.332

Allowable Shear Stress =


0.4116 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4116 x 1
2

=
0.4116 N/mm
Depth Required = 442967.35
0.4116 x 4600
=
309
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 150.527
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
110.947 kN/m2
1.925

Bending Moment = 110.947 x 1.925 x 1.925 / 2


= 205.56 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1704.01
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
184
180

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1744.44

mm

Provide 20 mm dia Bars @ 180 mm spacing bothways

i.e.0.333%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 180 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C21

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
235
F3-C21

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
2.369
776.811
6 1.2 (DL+LL+EQX)
-86.806
627.33
7 1.5 (DL+EQX)
-108.562 754.844
8 0.9DL+1.5EQX
-109.488 455.847
9 1.2 (DL+LL-EQX)
90.597
615.567
10 1.5 (DL-EQX)
113.191
740.14
11 0.9DL-1.5EQX
112.265 441.143
12 1.2 (DL+LL+EQZ)
2.387
657.064
13 1.5 (DL+EQZ)
2.929
792.011
14 0.9DL+1.5EQZ
2.003
493.014
15 1.2 (DL+LL-EQZ)
1.404
585.833
16 1.5 (DL-EQZ)
1.701
702.973
17 0.9DL-1.5EQZ
0.775
403.976

kN - m)
FORCE-Z
-80.583
-64.708
-72.978
-43.907
-64.226
-72.375
-43.305
-144.53
-172.75
-143.68
15.595
27.401
56.471

MOM-X
-235.482
-188.728
-213.62
-128.343
-188.043
-212.764
-127.487
-628.012
-762.725
-677.448
251.241
336.341
421.618

MOM-Y
4.08
7.996
9.241
7.911
-1.468
-2.589
-3.92
13.109
15.633
14.302
-6.581
-8.981
-10.31

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 776.811 + 600.79


= 1377.601 kN

MOM Z
-4.038
183.927
230.034
231.599
-190.387
-237.859
-236.294
-4.354
-5.317
-3.752
-2.107
-2.508
-0.943

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1377.601 / (3.3 x 4.6 )


=

90.751

kN/m

Mxx/Zxx = 235.482 / 11.638


Mxx/Zxx =

20.234

kN/m

Mzz/Zzz = 4.038 / 8.349


Mzz/Zzz =

0.484

kN/m

Maxi.Soil Pressure pmax = 90.751 + 20.234 + 0.484


pmax =

111.47

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 90.751 - 20.234 - 0.484
pmin =

70.04

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
235.52 kN.m
Calculation of Stabilizing Moment
Due to External Load = 776.811 x 3.3 / 2
=
1281.74 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1281.74 + 0 + 375.71 + 615.6
=
2273.05 kN.m
F.O.S. against Overturning = 2273.05 / 235.52
= 9.6512 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

80.62

kN

Total Vertical Load = 1377.6 kN


F.O.S. against Sliding = 1377.601 x 0.5 / 80.62
=
8.55
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
235 5 1.5 (DL+LL)
776.811 51.17332
F3-C21 6 1.2 (DL+LL+EQX)
627.33 41.32609
0
7 1.5 (DL+EQX)
754.844 49.72622
0
8 0.9DL+1.5EQX
455.847 30.02945
0
9 1.2 (DL+LL-EQX)
615.567 40.55119
0
10 1.5 (DL-EQX)
740.14 48.75758
0
11 0.9DL-1.5EQX
441.143 29.0608
0
12 1.2 (DL+LL+EQZ)
657.064 43.28485
0
13 1.5 (DL+EQZ)
792.011 52.17464
0
14 0.9DL+1.5EQZ
493.014 32.47787
0
15 1.2 (DL+LL-EQZ)
585.833 38.59242
0
16 1.5 (DL-EQZ)
702.973 46.30916
0
17 0.9DL-1.5EQZ
403.976 26.61238
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

20.24
16.22
18.36
11.03
16.16
18.29
10.96
53.97
65.54
58.22
21.59
28.91
36.23

0.49
22.03
27.56
27.74
22.81
28.49
28.31
0.53
0.64
0.45
0.26
0.31
0.12

71.9033
79.5761
95.6462
68.7994
79.5212
95.5376
68.3308
97.7848
118.355
91.1479
60.4424
75.5292
62.9624

140
166
166
166
166
166
166
166
166
166
166
166
166

30.45
3.08
3.81
-8.75
1.59
1.98
-10.21
-11.22
-14.01
-26.2
16.75
17.09
-9.74

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 71.90332 kN/m2
pmax = 118.3546 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
235 5 1.5 (DL+LL)
51.17332 20.24
F3-C21 6 1.2 (DL+LL+EQX)
41.32609 16.22
0
7 1.5 (DL+EQX)
49.72622 18.36
0
8 0.9DL+1.5EQX
30.02945 11.03
0
9 1.2 (DL+LL-EQX)
40.55119 16.16
0
10 1.5 (DL-EQX)
48.75758 18.29
0
11 0.9DL-1.5EQX
29.0608 10.96
0
12 1.2 (DL+LL+EQZ)
43.28485 53.97
0
13 1.5 (DL+EQZ)
52.17464 65.54
0
14 0.9DL+1.5EQZ
32.47787 58.22
0
15 1.2 (DL+LL-EQZ)
38.59242 21.59
0
16 1.5 (DL-EQZ)
46.30916 28.91
0
17 0.9DL-1.5EQZ
26.61238 36.23
Joint

kN/m2

Mzz/Zzz
(3)
0.49
22.03
27.56
27.74
22.81
28.49
28.31
0.53
0.64
0.45
0.26
0.31
0.12

pmin =

1+2+3

1-2+3

-26.2

1-2-3

kN/m2

1+2-3

71.904 31.424
30.444 70.924
79.577 47.137
3.077
35.517
95.647 58.927
3.807
40.527
68.8
46.74
-8.741
13.32
79.522 47.202
1.582
33.902
95.538 58.958
1.978
38.558
68.331 46.411
-10.21 11.711
97.785 -10.156 -11.216 96.725
118.355 -12.726 -14.006 117.08
91.148 -25.293 -26.193 90.248
60.443 17.263
16.743 59.923
75.53
17.71
17.09
74.91
62.963 -9.498
-9.738 62.723

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
235 5 1.5 (DL+LL)
1377.601 90.75105
F3-C21 6 1.2 (DL+LL+EQX)
1228.12 80.90382
0
7 1.5 (DL+EQX)
1355.634 89.30395
0
8 0.9DL+1.5EQX
1056.637 69.60718
0
9 1.2 (DL+LL-EQX)
1216.357 80.12892
0
10 1.5 (DL-EQX)
1340.93 88.33531
0
11 0.9DL-1.5EQX
1041.933 68.63854
0
12 1.2 (DL+LL+EQZ)
1257.854 82.86258
0
13 1.5 (DL+EQZ)
1392.801 91.75237
0
14 0.9DL+1.5EQZ
1093.804 72.0556
0
15 1.2 (DL+LL-EQZ)
1186.623 78.17016
0
16 1.5 (DL-EQZ)
1303.763 85.88689
0
17 0.9DL-1.5EQZ
1004.766 66.19012
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

20.24
16.22
18.36
11.03
16.16
18.29
10.96
53.97
65.54
58.22
21.59
28.91
36.23

0.49
22.03
27.56
27.74
22.81
28.49
28.31
0.53
0.64
0.45
0.26
0.31
0.12

111.481
119.154
135.224
108.377
119.099
135.115
107.909
137.363
157.932
130.726
100.02
115.107
102.54

140
166
166
166
166
166
166
166
166
166
166
166
166

70.03
42.66
43.39
30.84
41.16
41.56
29.37
28.37
25.58
13.39
56.33
56.67
29.85

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 111.4811 kN/m2
pmax = 157.9324 kN/m2
pmin =

70.03 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
235 5 1.5 (DL+LL)
90.75105 20.24
F3-C21 6 1.2 (DL+LL+EQX)
80.90382 16.22
0
7 1.5 (DL+EQX)
89.30395 18.36
0
8 0.9DL+1.5EQX
69.60718 11.03
0
9 1.2 (DL+LL-EQX)
80.12892 16.16
0
10 1.5 (DL-EQX)
88.33531 18.29
0
11 0.9DL-1.5EQX
68.63854 10.96
0
12 1.2 (DL+LL+EQZ)
82.86258 53.97
0
13 1.5 (DL+EQZ)
91.75237 65.54
0
14 0.9DL+1.5EQZ
72.0556 58.22
0
15 1.2 (DL+LL-EQZ)
78.17016 21.59
0
16 1.5 (DL-EQZ)
85.88689 28.91
0
17 0.9DL-1.5EQZ
66.19012 36.23
Joint

Mzz/Zzz
(3)
0.49
22.03
27.56
27.74
22.81
28.49
28.31
0.53
0.64
0.45
0.26
0.31
0.12

pmin =

13.39

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

111.482
119.154
135.224
108.378
119.099
135.116
107.909
137.363
157.933
130.726
100.021
115.107
102.541

71.002
86.714
98.504
86.318
86.779
98.536
85.989
29.423
26.853
14.286
56.841
57.287
30.081

70.022
42.654
43.384
30.838
41.159
41.556
29.369
28.363
25.573
13.386
56.321
56.667
29.841

110.5
75.094
80.104
52.898
73.479
78.136
51.289
136.3
156.65
129.83
99.501
114.49
102.3

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
235
F3-C21
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
235.5166 991.31
6 1.2 (DL+LL+EQX)
263.5287 991.31
7 1.5 (DL+EQX)
313.9254 991.31
8 0.9DL+1.5EQX
264.783 991.31
9 1.2 (DL+LL-EQX)
267.5956 991.31
10 1.5 (DL-EQX)
319.1323 991.31
11 0.9DL-1.5EQX
268.4917 991.31
12 1.2 (DL+LL+EQZ)
628.0271 991.31
13 1.5 (DL+EQZ)
762.7435 991.31
14 0.9DL+1.5EQZ
677.4584 991.31
15 1.2 (DL+LL-EQZ)
251.2498 991.31
16 1.5 (DL-EQZ)
336.3504 991.31
17 0.9DL-1.5EQZ
421.6191 991.31

1281.74
1035.1
1245.5
752.15
1015.69
1221.24
727.89
1084.16
1306.82
813.48
966.63
1159.91
666.57

9.66
7.69
7.13
6.59
7.51
6.94
6.41
3.31
3.02
2.67
7.8
6.4
3.94

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
80.61781
108.2701
130.8109
117.9638
111.0531
134.3516
120.3277
144.5487
172.7788
143.697
15.65807
27.45375
56.47632

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.352

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1377.6
1228.1
1355.6
1056.6
1216.4
1340.9
1041.9
1257.9
1392.8
1093.8
1186.6
1303.8
1004.8

8.55
5.68
5.19
4.48
5.48
5
4.33
4.36
4.04
3.81
37.9
23.75
8.9

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 792.011 kN
Punching Shear,P =
792.011 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 723.83 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 723830


=
1.37 x4600
= 114.86 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
157.933

kN/m2

B) One Way Shear


1400
0

1925

157.544

kN/m2

157.398

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

26.853

kN/m2
102.324 kN/m2

157.933

kN/m2

123.177

kN/m2

156.653

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 123.177 - 25 x 0.6 - 18 x ( 2 82.977 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 82.977 x 3.3 x 1.4
= 383.3537 kN
At Width
Maximum Pressure = 157.544 - 25 x 0.6 - 18 x ( 2 117.344 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 117.344 x 4.6 x 0.875
= 472.3096 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 472.3096 kN


Corresponding Length =
4600
mm
% Ast =

0.352

Allowable Shear Stress =


0.422
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.422 x 1
2

N/mm
=
0.422
Depth Required = 472309.6
0.422 x 4600
=
319
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 157.933
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
118.353 kN/m2
1.925

Bending Moment = 118.353 x 1.925 x 1.925 / 2


= 219.29 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1823.85
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
172
170

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1847.06

mm

Provide 20 mm dia Bars @ 170 mm spacing bothways

i.e.0.352%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 170 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C22

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
236
F3-C22

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
1.491
783.838
6 1.2 (DL+LL+EQX)
-86.917 626.349
7 1.5 (DL+EQX)
-108.719 753.356
8 0.9DL+1.5EQX
-109.286 451.653
9 1.2 (DL+LL-EQX)
89.303
627.791
10 1.5 (DL-EQX)
111.557 755.158
11 0.9DL-1.5EQX
110.989 453.455
12 1.2 (DL+LL+EQZ)
1.61
665.027
13 1.5 (DL+EQZ)
1.94
801.703
14 0.9DL+1.5EQZ
1.373
500
15 1.2 (DL+LL-EQZ)
0.776
589.113
16 1.5 (DL-EQZ)
0.898
706.811
17 0.9DL-1.5EQZ
0.33
405.108

kN - m)
FORCE-Z
-84.172
-67.277
-75.508
-45.274
-67.398
-75.659
-45.426
-155.28
-185.51
-155.28
20.603
34.342
64.575

MOM-X
-237.289
-189.643
-213.175
-127.811
-190.02
-213.646
-128.282
-669.856
-813.442
-728.078
290.194
386.621
471.985

MOM-Y
-1.608
3.86
4.885
5.504
-6.434
-7.983
-7.363
1.716
2.204
2.824
-4.289
-5.302
-4.683

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 783.838 + 600.79


= 1384.628 kN

MOM Z
-2.978
184.135
230.306
231.442
-188.899
-235.986
-234.85
-3.314
-4.004
-2.868
-1.451
-1.676
-0.54

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1384.628 / (3.3 x 4.6 )


=

91.214

kN/m

Mxx/Zxx = 237.289 / 11.638


Mxx/Zxx =

20.390

kN/m

Mzz/Zzz = 2.978 / 8.349


Mzz/Zzz =

0.357

kN/m

Maxi.Soil Pressure pmax = 91.214 + 20.39 + 0.357


pmax =

111.97

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 91.214 - 20.39 - 0.357
pmin =

70.47

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
237.31 kN.m
Calculation of Stabilizing Moment
Due to External Load = 783.838 x 3.3 / 2
=
1293.34 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1293.34 + 0 + 375.71 + 615.6
=
2284.65 kN.m
F.O.S. against Overturning = 2284.65 / 237.31
= 9.62728 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

84.19

kN

Total Vertical Load = 1384.63 kN


F.O.S. against Sliding = 1384.628 x 0.5 / 84.19
=
8.23
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
236 5 1.5 (DL+LL)
783.838 51.63623
F3-C22 6 1.2 (DL+LL+EQX)
626.349 41.26146
0
7 1.5 (DL+EQX)
753.356 49.62819
0
8 0.9DL+1.5EQX
451.653 29.75316
0
9 1.2 (DL+LL-EQX)
627.791 41.35646
0
10 1.5 (DL-EQX)
755.158 49.7469
0
11 0.9DL-1.5EQX
453.455 29.87187
0
12 1.2 (DL+LL+EQZ)
665.027 43.80942
0
13 1.5 (DL+EQZ)
801.703 52.81311
0
14 0.9DL+1.5EQZ
500
32.93808
0
15 1.2 (DL+LL-EQZ)
589.113 38.8085
0
16 1.5 (DL-EQZ)
706.811 46.56199
0
17 0.9DL-1.5EQZ
405.108 26.68696
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

20.39
16.3
18.32
10.99
16.33
18.36
11.03
57.56
69.9
62.57
24.94
33.23
40.56

0.36
22.06
27.59
27.73
22.63
28.27
28.13
0.4
0.48
0.35
0.18
0.21
0.07

72.3862
79.6215
95.5382
68.4732
80.3165
96.3769
69.0319
101.769
123.193
95.8581
63.9285
80.002
67.317

140
166
166
166
166
166
166
166
166
166
166
166
166

30.89
2.91
3.72
-8.97
2.4
3.12
-9.29
-14.16
-17.57
-29.99
13.69
13.13
-13.95

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 72.38623 kN/m2
pmax = 123.1931 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
236 5 1.5 (DL+LL)
51.63623 20.39
F3-C22 6 1.2 (DL+LL+EQX)
41.26146
16.3
0
7 1.5 (DL+EQX)
49.62819 18.32
0
8 0.9DL+1.5EQX
29.75316 10.99
0
9 1.2 (DL+LL-EQX)
41.35646 16.33
0
10 1.5 (DL-EQX)
49.7469 18.36
0
11 0.9DL-1.5EQX
29.87187 11.03
0
12 1.2 (DL+LL+EQZ)
43.80942 57.56
0
13 1.5 (DL+EQZ)
52.81311
69.9
0
14 0.9DL+1.5EQZ
32.93808 62.57
0
15 1.2 (DL+LL-EQZ)
38.8085 24.94
0
16 1.5 (DL-EQZ)
46.56199 33.23
0
17 0.9DL-1.5EQZ
26.68696 40.56
Joint

kN/m2

Mzz/Zzz
(3)
0.36
22.06
27.59
27.73
22.63
28.27
28.13
0.4
0.48
0.35
0.18
0.21
0.07

pmin =

-29.99 kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

72.387
79.622
95.539
68.474
80.317
96.377
69.032
101.77
123.194
95.859
63.929
80.002
67.317

31.607
47.022
58.899
46.494
47.657
59.657
46.972
-13.351
-16.607
-29.282
14.049
13.542
-13.804

30.887
2.902
3.719
-8.967
2.397
3.117
-9.289
-14.151
-17.567
-29.982
13.689
13.122
-13.944

71.667
35.502
40.359
13.014
35.057
39.837
12.772
100.97
122.23
95.159
63.569
79.582
67.177

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
236 5 1.5 (DL+LL)
1384.628 91.21397
F3-C22 6 1.2 (DL+LL+EQX)
1227.139 80.8392
0
7 1.5 (DL+EQX)
1354.146 89.20593
0
8 0.9DL+1.5EQX
1052.443 69.3309
0
9 1.2 (DL+LL-EQX)
1228.581 80.93419
0
10 1.5 (DL-EQX)
1355.948 89.32464
0
11 0.9DL-1.5EQX
1054.245 69.4496
0
12 1.2 (DL+LL+EQZ)
1265.817 83.38715
0
13 1.5 (DL+EQZ)
1402.493 92.39084
0
14 0.9DL+1.5EQZ
1100.79 72.51581
0
15 1.2 (DL+LL-EQZ)
1189.903 78.38623
0
16 1.5 (DL-EQZ)
1307.601 86.13972
0
17 0.9DL-1.5EQZ
1005.898 66.26469
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

20.39
16.3
18.32
10.99
16.33
18.36
11.03
57.56
69.9
62.57
24.94
33.23
40.56

0.36
22.06
27.59
27.73
22.63
28.27
28.13
0.4
0.48
0.35
0.18
0.21
0.07

111.964
119.199
135.116
108.051
119.894
135.955
108.61
141.347
162.771
135.436
103.506
119.58
106.895

140
166
166
166
166
166
166
166
166
166
166
166
166

70.47
42.48
43.3
30.62
41.98
42.7
30.29
25.43
22.02
9.6
53.27
52.7
25.64

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 111.964 kN/m2
pmax = 162.7708 kN/m2
pmin =

70.47 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
236 5 1.5 (DL+LL)
91.21397 20.39
F3-C22 6 1.2 (DL+LL+EQX)
80.8392
16.3
0
7 1.5 (DL+EQX)
89.20593 18.32
0
8 0.9DL+1.5EQX
69.3309 10.99
0
9 1.2 (DL+LL-EQX)
80.93419 16.33
0
10 1.5 (DL-EQX)
89.32464 18.36
0
11 0.9DL-1.5EQX
69.4496 11.03
0
12 1.2 (DL+LL+EQZ)
83.38715 57.56
0
13 1.5 (DL+EQZ)
92.39084
69.9
0
14 0.9DL+1.5EQZ
72.51581 62.57
0
15 1.2 (DL+LL-EQZ)
78.38623 24.94
0
16 1.5 (DL-EQZ)
86.13972 33.23
0
17 0.9DL-1.5EQZ
66.26469 40.56
Joint

Mzz/Zzz
(3)
0.36
22.06
27.59
27.73
22.63
28.27
28.13
0.4
0.48
0.35
0.18
0.21
0.07

pmin =

9.6

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

111.964
119.2
135.116
108.051
119.895
135.955
108.61
141.348
162.771
135.436
103.507
119.58
106.895

71.184
86.6
98.476
86.071
87.235
99.235
86.55
26.228
22.971
10.296
53.627
53.12
25.775

70.464
42.48
43.296
30.611
41.975
42.695
30.29
25.428
22.011
9.596
53.267
52.7
25.635

111.24
75.08
79.936
52.591
74.635
79.415
52.35
140.55
161.81
134.74
103.15
119.16
106.76

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
236
F3-C22
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
237.3077 991.31
6 1.2 (DL+LL+EQX)
264.3297 991.31
7 1.5 (DL+EQX)
313.8223 991.31
8 0.9DL+1.5EQX
264.3881 991.31
9 1.2 (DL+LL-EQX)
267.9374 991.31
10 1.5 (DL-EQX)
318.33
991.31
11 0.9DL-1.5EQX
267.6019 991.31
12 1.2 (DL+LL+EQZ)
669.8642 991.31
13 1.5 (DL+EQZ)
813.4519 991.31
14 0.9DL+1.5EQZ
728.0836 991.31
15 1.2 (DL+LL-EQZ)
290.1976 991.31
16 1.5 (DL-EQZ)
386.6246 991.31
17 0.9DL-1.5EQZ
471.9853 991.31

1293.34
1033.48
1243.04
745.23
1035.86
1246.02
748.21
1097.3
1322.81
825
972.04
1166.24
668.43

9.63
7.67
7.12
6.57
7.57
7.03
6.51
3.12
2.85
2.5
6.77
5.59
3.52

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
84.1852
109.9125
132.368
118.2927
111.8817
134.7934
119.9253
155.2863
185.5191
155.2821
20.61761
34.35374
64.57584

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.362

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1384.6
1227.1
1354.1
1052.4
1228.6
1355.9
1054.2
1265.8
1402.5
1100.8
1189.9
1307.6
1005.9

8.23
5.59
5.12
4.45
5.5
5.03
4.4
4.08
3.78
3.55
28.86
19.04
7.79

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 801.703 kN
Punching Shear,P =
801.703 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 732.69 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 732690


=
1.37 x4600
= 116.26 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
162.771

kN/m2

B) One Way Shear


1400
0

1925

162.479

kN/m2

162.37

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

22.971

kN/m2
103.462 kN/m2

162.771

kN/m2

125.703

kN/m2

161.811

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 125.703 - 25 x 0.6 - 18 x ( 2 85.503 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 85.503 x 3.3 x 1.4
= 395.0239 kN
At Width
Maximum Pressure = 162.479 - 25 x 0.6 - 18 x ( 2 122.279 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 122.279 x 4.6 x 0.875
= 492.173 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 492.17298 kN


Corresponding Length =
4600
mm
% Ast =

0.362

Allowable Shear Stress =


0.4272 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4272 x 1
2

=
0.4272 N/mm
Depth Required = 492172.98
0.4272 x 4600
=
326
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 162.771
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
123.191 kN/m2
1.925

Bending Moment = 123.191 x 1.925 x 1.925 / 2


= 228.25 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1902.52
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
165
165

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1903.03

mm

Provide 20 mm dia Bars @ 165 mm spacing bothways

i.e.0.363%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 165 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C23

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
237
F3-C23

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
1.605
783.187
6 1.2 (DL+LL+EQX)
-86.821 626.912
7 1.5 (DL+EQX)
-108.573 754.163
8 0.9DL+1.5EQX
-109.196 452.679
9 1.2 (DL+LL-EQX)
89.389
626.188
10 1.5 (DL-EQX)
111.689 753.258
11 0.9DL-1.5EQX
111.066 451.774
12 1.2 (DL+LL+EQZ)
1.603
665.636
13 1.5 (DL+EQZ)
1.956
802.568
14 0.9DL+1.5EQZ
1.333
501.084
15 1.2 (DL+LL-EQZ)
0.966
587.464
16 1.5 (DL-EQZ)
1.159
704.853
17 0.9DL-1.5EQZ
0.536
403.369

kN - m)
FORCE-Z
-83.161
-66.552
-74.648
-44.8
-66.506
-74.592
-44.744
-156.26
-186.78
-156.93
23.201
37.542
67.39

MOM-X
-232.219
-185.788
-208.483
-125.096
-185.762
-208.451
-125.064
-677.627
-823.281
-739.894
306.076
406.347
489.734

MOM-Y
-0.042
5.093
6.335
6.364
-5.161
-6.482
-6.453
0.951
1.157
1.187
-1.018
-1.305
-1.275

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 783.187 + 600.79


= 1383.977 kN

MOM Z
-3.073
184.12
230.255
231.442
-189.038
-236.193
-235.005
-3.165
-3.851
-2.664
-1.753
-2.087
-0.899

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1383.977 / (3.3 x 4.6 )


=

91.171

kN/m

Mxx/Zxx = 232.219 / 11.638


Mxx/Zxx =

19.954

kN/m

Mzz/Zzz = 3.073 / 8.349


Mzz/Zzz =

0.369

kN/m

Maxi.Soil Pressure pmax = 91.171 + 19.954 + 0.369


pmax =

111.50

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 91.171 - 19.954 - 0.369
pmin =

70.85

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
232.24 kN.m
Calculation of Stabilizing Moment
Due to External Load = 783.187 x 3.3 / 2
=
1292.26 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1292.26 + 0 + 375.71 + 615.6
=
2283.57 kN.m
F.O.S. against Overturning = 2283.57 / 232.24
= 9.8328 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

83.18

kN

Total Vertical Load = 1383.98 kN


F.O.S. against Sliding = 1383.977 x 0.5 / 83.18
=
8.32
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
237 5 1.5 (DL+LL)
783.187 51.59335
F3-C23 6 1.2 (DL+LL+EQX)
626.912 41.29855
0
7 1.5 (DL+EQX)
754.163 49.68136
0
8 0.9DL+1.5EQX
452.679 29.82075
0
9 1.2 (DL+LL-EQX)
626.188 41.25086
0
10 1.5 (DL-EQX)
753.258 49.62174
0
11 0.9DL-1.5EQX
451.774 29.76113
0
12 1.2 (DL+LL+EQZ)
665.636 43.84954
0
13 1.5 (DL+EQZ)
802.568 52.87009
0
14 0.9DL+1.5EQZ
501.084 33.00949
0
15 1.2 (DL+LL-EQZ)
587.464 38.69987
0
16 1.5 (DL-EQZ)
704.853 46.433
0
17 0.9DL-1.5EQZ
403.369 26.5724
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

19.96
15.97
17.92
10.75
15.97
17.92
10.75
58.23
70.75
63.58
26.3
34.92
42.09

0.37
22.06
27.58
27.73
22.65
28.29
28.15
0.38
0.47
0.32
0.21
0.25
0.11

71.9233
79.3286
95.1814
68.3008
79.8709
95.8317
68.6611
102.46
124.09
96.9095
65.2099
81.603
68.7724

140
166
166
166
166
166
166
166
166
166
166
166
166

31.27
3.27
4.19
-8.66
2.64
3.42
-9.14
-14.77
-18.35
-30.9
12.19
11.27
-15.63

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 71.92335 kN/m2
pmax = 124.0901 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
237 5 1.5 (DL+LL)
51.59335 19.96
F3-C23 6 1.2 (DL+LL+EQX)
41.29855 15.97
0
7 1.5 (DL+EQX)
49.68136 17.92
0
8 0.9DL+1.5EQX
29.82075 10.75
0
9 1.2 (DL+LL-EQX)
41.25086 15.97
0
10 1.5 (DL-EQX)
49.62174 17.92
0
11 0.9DL-1.5EQX
29.76113 10.75
0
12 1.2 (DL+LL+EQZ)
43.84954 58.23
0
13 1.5 (DL+EQZ)
52.87009 70.75
0
14 0.9DL+1.5EQZ
33.00949 63.58
0
15 1.2 (DL+LL-EQZ)
38.69987
26.3
0
16 1.5 (DL-EQZ)
46.433 34.92
0
17 0.9DL-1.5EQZ
26.5724 42.09
Joint

kN/m2

Mzz/Zzz
(3)
0.37
22.06
27.58
27.73
22.65
28.29
28.15
0.38
0.47
0.32
0.21
0.25
0.11

pmin =

1+2+3

1-2+3

-30.9

1-2-3

kN/m2

1+2-3

71.924 32.004
31.264 71.184
79.329 47.389
3.269
35.209
95.182 59.342
4.182
40.022
68.301 46.801
-8.66
12.841
79.871 47.931
2.631
34.571
95.832 59.992
3.412
39.252
68.662 47.162
-9.139 12.362
102.46 -14.001 -14.761 101.7
124.091 -17.41
-18.35 123.15
96.91 -30.251 -30.891 96.27
65.21
12.61
12.19
64.79
81.604 11.764
11.264 81.104
68.773 -15.408 -15.628 68.553

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
237 5 1.5 (DL+LL)
1383.977 91.17108
F3-C23 6 1.2 (DL+LL+EQX)
1227.702 80.87628
0
7 1.5 (DL+EQX)
1354.953 89.25909
0
8 0.9DL+1.5EQX
1053.469 69.39848
0
9 1.2 (DL+LL-EQX)
1226.978 80.82859
0
10 1.5 (DL-EQX)
1354.048 89.19947
0
11 0.9DL-1.5EQX
1052.564 69.33887
0
12 1.2 (DL+LL+EQZ)
1266.426 83.42727
0
13 1.5 (DL+EQZ)
1403.358 92.44783
0
14 0.9DL+1.5EQZ
1101.874 72.58722
0
15 1.2 (DL+LL-EQZ)
1188.254 78.2776
0
16 1.5 (DL-EQZ)
1305.643 86.01074
0
17 0.9DL-1.5EQZ
1004.159 66.15013
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

19.96
15.97
17.92
10.75
15.97
17.92
10.75
58.23
70.75
63.58
26.3
34.92
42.09

0.37
22.06
27.58
27.73
22.65
28.29
28.15
0.38
0.47
0.32
0.21
0.25
0.11

111.501
118.906
134.759
107.878
119.449
135.409
108.239
142.037
163.668
136.487
104.788
121.181
108.35

140
166
166
166
166
166
166
166
166
166
166
166
166

70.85
42.85
43.76
30.92
42.21
42.99
30.44
24.82
21.23
8.69
51.77
50.85
23.96

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 111.5011 kN/m2
pmax = 163.6678 kN/m2
pmin =

70.85 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
237 5 1.5 (DL+LL)
91.17108 19.96
F3-C23 6 1.2 (DL+LL+EQX)
80.87628 15.97
0
7 1.5 (DL+EQX)
89.25909 17.92
0
8 0.9DL+1.5EQX
69.39848 10.75
0
9 1.2 (DL+LL-EQX)
80.82859 15.97
0
10 1.5 (DL-EQX)
89.19947 17.92
0
11 0.9DL-1.5EQX
69.33887 10.75
0
12 1.2 (DL+LL+EQZ)
83.42727 58.23
0
13 1.5 (DL+EQZ)
92.44783 70.75
0
14 0.9DL+1.5EQZ
72.58722 63.58
0
15 1.2 (DL+LL-EQZ)
78.2776
26.3
0
16 1.5 (DL-EQZ)
86.01074 34.92
0
17 0.9DL-1.5EQZ
66.15013 42.09
Joint

Mzz/Zzz
(3)
0.37
22.06
27.58
27.73
22.65
28.29
28.15
0.38
0.47
0.32
0.21
0.25
0.11

pmin =

8.69

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

111.502
118.907
134.76
107.879
119.449
135.41
108.239
142.038
163.668
136.488
104.788
121.181
108.351

71.582
86.967
98.92
86.379
87.509
99.57
86.739
25.578
22.168
9.328
52.188
51.341
24.171

70.842
42.847
43.76
30.919
42.209
42.99
30.439
24.818
21.228
8.688
51.768
50.841
23.951

110.76
74.787
79.6
52.419
74.149
78.83
51.939
141.28
162.73
135.85
104.37
120.68
108.13

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
237
F3-C23
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
232.2393 991.31
6 1.2 (DL+LL+EQX)
261.5671 991.31
7 1.5 (DL+EQX)
310.6164 991.31
8 0.9DL+1.5EQX
263.0863 991.31
9 1.2 (DL+LL-EQX)
265.0337 991.31
10 1.5 (DL-EQX)
315.0221 991.31
11 0.9DL-1.5EQX
266.2111 991.31
12 1.2 (DL+LL+EQZ)
677.6344 991.31
13 1.5 (DL+EQZ)
823.29
991.31
14 0.9DL+1.5EQZ
739.8988 991.31
15 1.2 (DL+LL-EQZ)
306.081 991.31
16 1.5 (DL-EQZ)
406.3524 991.31
17 0.9DL-1.5EQZ
489.7348 991.31

1292.26
1034.41
1244.37
746.93
1033.22
1242.88
745.43
1098.3
1324.24
826.79
969.32
1163.01
665.56

9.84
7.75
7.2
6.61
7.64
7.1
6.53
3.09
2.82
2.46
6.41
5.31
3.39

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
83.17649
109.394
131.7589
118.0288
111.4156
134.3071
119.7401
156.2662
186.7922
156.9397
23.2211
37.55989
67.39213

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.374

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1384
1227.7
1355
1053.5
1227
1354
1052.6
1266.4
1403.4
1101.9
1188.3
1305.6
1004.2

8.32
5.62
5.15
4.47
5.51
5.05
4.4
4.06
3.76
3.52
25.59
17.39
7.46

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 802.568 kN
Punching Shear,P =
802.568 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 733.48 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 733480


=
1.37 x4600
= 116.39 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
163.668

kN/m2

B) One Way Shear


1400
0

1925

163.382

kN/m2

163.275

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

22.168

kN/m2
103.638 kN/m2

163.668

kN/m2

126.15

kN/m2

162.728

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

At Length
Maximum Pressure = 126.15 - 25 x 0.6 - 18 x ( 2 - 0.6 )
85.95 kN/m2
-- For without Buoynacy Condition With Stress Increse
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 85.95 x 3.3 x 1.4
= 397.089 kN
At Width
Maximum Pressure = 163.382 - 25 x 0.6 - 18 x ( 2 - 0.6 )
123.182 kN/m2
-- For without Buoynacy Condition With Stress Increse
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 123.182 x 4.6 x 0.875
= 495.8076 kN
Designed Shear Strength = 495.80755 kN
Corresponding Length =
4600
mm
% Ast =

0.374

Allowable Shear Stress =


0.4324 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4324 x 1
2

=
0.4324 N/mm
Depth Required = 495807.55
0.4324 x 4600
=
325
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 163.668
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
124.088 kN/m2
1.925

Bending Moment = 124.088 x 1.925 x 1.925 / 2


= 229.91 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1917.13
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
163
160

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1962.5

mm

Provide 20 mm dia Bars @ 160 mm spacing bothways

i.e.0.374%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 160 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C24

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
238
F3-C24

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
0.122
763.931
6 1.2 (DL+LL+EQX)
-88.883 599.683
7 1.5 (DL+EQX)
-111.195 721.038
8 0.9DL+1.5EQX
-111.207 426.892
9 1.2 (DL+LL-EQX)
89.078
622.607
10 1.5 (DL-EQX)
111.257 749.693
11 0.9DL-1.5EQX
111.244 455.547
12 1.2 (DL+LL+EQZ)
0.327
650.833
13 1.5 (DL+EQZ)
0.317
784.976
14 0.9DL+1.5EQZ
0.305
490.83
15 1.2 (DL+LL-EQZ)
-0.132
571.457
16 1.5 (DL-EQZ)
-0.256
685.755
17 0.9DL-1.5EQZ
-0.268
391.609

kN - m)
FORCE-Z
-74.036
-59.021
-66.151
-39.587
-59.437
-66.672
-40.108
-149.73
-179.54
-152.97
31.272
46.715
73.28

MOM-X
-210.743
-168.141
-188.499
-112.872
-169.047
-189.632
-114.006
-666.047
-810.882
-735.255
328.859
432.751
508.377

MOM-Y
-8.39
-1.921
-1.555
1.463
-11.5
-13.53
-10.52
-5.413
-5.921
-2.903
-8.011
-9.168
-6.15

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 763.931 + 600.79


= 1364.721 kN

MOM Z
-1.387
186.562
233.352
233.847
-188.781
-235.828
-235.333
-1.597
-1.848
-1.352
-0.622
-0.629
-0.133

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1364.721 / (3.3 x 4.6 )


=

89.903

kN/m

Mxx/Zxx = 210.743 / 11.638


Mxx/Zxx =

18.109

kN/m

Mzz/Zzz = 1.387 / 8.349


Mzz/Zzz =

0.167

kN/m

Maxi.Soil Pressure pmax = 89.903 + 18.109 + 0.167


pmax =

108.18

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 89.903 - 18.109 - 0.167
pmin =

71.63

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
210.75 kN.m
Calculation of Stabilizing Moment
Due to External Load = 763.931 x 3.3 / 2
=
1260.49 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1260.49 + 0 + 375.71 + 615.6
=
2251.8 kN.m
F.O.S. against Overturning = 2251.8 / 210.75
= 10.6847 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

74.04

kN

Total Vertical Load = 1364.72 kN


F.O.S. against Sliding = 1364.721 x 0.5 / 74.04
=
9.22
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
238 5 1.5 (DL+LL)
763.931 50.32484
F3-C24 6 1.2 (DL+LL+EQX)
599.683 39.50481
0
7 1.5 (DL+EQX)
721.038 47.49921
0
8 0.9DL+1.5EQX
426.892 28.122
0
9 1.2 (DL+LL-EQX)
622.607 41.01495
0
10 1.5 (DL-EQX)
749.693 49.38689
0
11 0.9DL-1.5EQX
455.547 30.00968
0
12 1.2 (DL+LL+EQZ)
650.833 42.87437
0
13 1.5 (DL+EQZ)
784.976 51.7112
0
14 0.9DL+1.5EQZ
490.83 32.33399
0
15 1.2 (DL+LL-EQZ)
571.457 37.64539
0
16 1.5 (DL-EQZ)
685.755 45.1749
0
17 0.9DL-1.5EQZ
391.609 25.79769
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

18.11
14.45
16.2
9.7
14.53
16.3
9.8
57.24
69.68
63.18
28.26
37.19
43.69

0.17
22.35
27.95
28.01
22.62
28.25
28.19
0.2
0.23
0.17
0.08
0.08
0.02

68.6048
76.3048
91.6492
65.832
78.165
93.9369
67.9997
100.314
121.621
95.684
65.9854
82.4449
69.5077

140
166
166
166
166
166
166
166
166
166
166
166
166

32.05
2.71
3.35
-9.59
3.87
4.84
-7.99
-14.57
-18.2
-31.02
9.31
7.91
-17.92

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 68.60484 kN/m2
pmax = 121.6212 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
238 5 1.5 (DL+LL)
50.32484 18.11
F3-C24 6 1.2 (DL+LL+EQX)
39.50481 14.45
0
7 1.5 (DL+EQX)
47.49921
16.2
0
8 0.9DL+1.5EQX
28.122
9.7
0
9 1.2 (DL+LL-EQX)
41.01495 14.53
0
10 1.5 (DL-EQX)
49.38689
16.3
0
11 0.9DL-1.5EQX
30.00968
9.8
0
12 1.2 (DL+LL+EQZ)
42.87437 57.24
0
13 1.5 (DL+EQZ)
51.7112 69.68
0
14 0.9DL+1.5EQZ
32.33399 63.18
0
15 1.2 (DL+LL-EQZ)
37.64539 28.26
0
16 1.5 (DL-EQZ)
45.1749 37.19
0
17 0.9DL-1.5EQZ
25.79769 43.69
Joint

kN/m2

Mzz/Zzz
(3)
0.17
22.35
27.95
28.01
22.62
28.25
28.19
0.2
0.23
0.17
0.08
0.08
0.02

pmin =

-31.02 kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

68.605
76.305
91.65
65.833
78.165
93.937
68
100.315
121.622
95.684
65.986
82.445
69.508

32.385
47.405
59.25
46.433
49.105
61.337
48.4
-14.166
-17.739
-30.677
9.466
8.065
-17.873

32.045
2.705
3.35
-9.588
3.865
4.837
-7.981
-14.566
-18.199
-31.017
9.306
7.905
-17.913

68.265
31.605
35.75
9.813
32.925
37.437
11.62
99.915
121.16
95.344
65.826
82.285
69.468

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
238 5 1.5 (DL+LL)
1364.721 89.90257
F3-C24 6 1.2 (DL+LL+EQX)
1200.473 79.08254
0
7 1.5 (DL+EQX)
1321.828 87.07694
0
8 0.9DL+1.5EQX
1027.682 67.69974
0
9 1.2 (DL+LL-EQX)
1223.397 80.59269
0
10 1.5 (DL-EQX)
1350.483 88.96462
0
11 0.9DL-1.5EQX
1056.337 69.58742
0
12 1.2 (DL+LL+EQZ)
1251.623 82.45211
0
13 1.5 (DL+EQZ)
1385.766 91.28893
0
14 0.9DL+1.5EQZ
1091.62 71.91173
0
15 1.2 (DL+LL-EQZ)
1172.247 77.22312
0
16 1.5 (DL-EQZ)
1286.545 84.75264
0
17 0.9DL-1.5EQZ
992.399 65.37543
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

18.11
14.45
16.2
9.7
14.53
16.3
9.8
57.24
69.68
63.18
28.26
37.19
43.69

0.17
22.35
27.95
28.01
22.62
28.25
28.19
0.2
0.23
0.17
0.08
0.08
0.02

108.183
115.883
131.227
105.41
117.743
133.515
107.577
139.892
161.199
135.262
105.563
122.023
109.085

140
166
166
166
166
166
166
166
166
166
166
166
166

71.63
42.29
42.93
29.99
43.45
44.42
31.6
25.02
21.38
8.57
48.89
47.49
21.67

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 108.1826 kN/m2
pmax = 161.1989 kN/m2
pmin =

71.63 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
238 5 1.5 (DL+LL)
89.90257 18.11
F3-C24 6 1.2 (DL+LL+EQX)
79.08254 14.45
0
7 1.5 (DL+EQX)
87.07694
16.2
0
8 0.9DL+1.5EQX
67.69974
9.7
0
9 1.2 (DL+LL-EQX)
80.59269 14.53
0
10 1.5 (DL-EQX)
88.96462
16.3
0
11 0.9DL-1.5EQX
69.58742
9.8
0
12 1.2 (DL+LL+EQZ)
82.45211 57.24
0
13 1.5 (DL+EQZ)
91.28893 69.68
0
14 0.9DL+1.5EQZ
71.91173 63.18
0
15 1.2 (DL+LL-EQZ)
77.22312 28.26
0
16 1.5 (DL-EQZ)
84.75264 37.19
0
17 0.9DL-1.5EQZ
65.37543 43.69
Joint

Mzz/Zzz
(3)
0.17
22.35
27.95
28.01
22.62
28.25
28.19
0.2
0.23
0.17
0.08
0.08
0.02

pmin =

1+2+3

1-2+3

108.183 71.963
115.883 86.983
131.227 98.827
105.41
86.01
117.743 88.683
133.515 100.915
107.578 87.978
139.893 25.413
161.199 21.839
135.262 8.902
105.564 49.044
122.023 47.643
109.086 21.706

8.57

kN/m2

1-2-3

1+2-3

71.623
42.283
42.927
29.99
43.443
44.415
31.598
25.013
21.379
8.562
48.884
47.483
21.666

107.84
71.183
75.327
49.39
72.503
77.015
51.198
139.49
160.74
134.92
105.4
121.86
109.05

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
238
F3-C24
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
210.7476 991.31
6 1.2 (DL+LL+EQX)
251.1509 991.31
7 1.5 (DL+EQX)
299.975 991.31
8 0.9DL+1.5EQX
259.6623 991.31
9 1.2 (DL+LL-EQX)
253.4071 991.31
10 1.5 (DL-EQX)
302.6138 991.31
11 0.9DL-1.5EQX
261.4938 991.31
12 1.2 (DL+LL+EQZ)
666.0489 991.31
13 1.5 (DL+EQZ)
810.8841 991.31
14 0.9DL+1.5EQZ
735.2562 991.31
15 1.2 (DL+LL-EQZ)
328.8596 991.31
16 1.5 (DL-EQZ)
432.7515 991.31
17 0.9DL-1.5EQZ
508.377 991.31

1260.49
989.48
1189.72
704.38
1027.31
1237
751.66
1073.88
1295.22
809.87
942.91
1131.5
646.16

10.69
7.89
7.28
6.54
7.97
7.37
6.67
3.11
2.82
2.45
5.89
4.91
3.23

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
74.0361
106.6943
129.3842
118.0429
107.0871
129.7046
118.2535
149.7314
179.5393
152.9743
31.27228
46.7157
73.28049

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.362

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1364.7
1200.5
1321.8
1027.7
1223.4
1350.5
1056.3
1251.6
1385.8
1091.6
1172.2
1286.5
992.4

9.22
5.63
5.11
4.36
5.72
5.21
4.47
4.18
3.86
3.57
18.75
13.77
6.78

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 784.976 kN
Punching Shear,P =
784.976 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 717.4 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 717400


=
1.37 x4600
= 113.84 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
161.199

kN/m2

B) One Way Shear


1400
0

1925

161.059

kN/m2

161.007

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

21.839

kN/m2
102.077 kN/m2

161.199

kN/m2

124.248

kN/m2

160.739

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 124.248 - 25 x 0.6 - 18 x ( 2 84.048 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 84.048 x 3.3 x 1.4
= 388.3018 kN
At Width
Maximum Pressure = 161.059 - 25 x 0.6 - 18 x ( 2 120.859 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 120.859 x 4.6 x 0.875
= 486.4575 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 486.45748 kN


Corresponding Length =
4600
mm
% Ast =

0.362

Allowable Shear Stress =


0.4272 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4272 x 1
2

=
0.4272 N/mm
Depth Required = 486457.48
0.4272 x 4600
=
323
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 161.199
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
121.619 kN/m2
1.925

Bending Moment = 121.619 x 1.925 x 1.925 / 2


= 225.34 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1876.93
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
167
165

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1903.03

mm

Provide 20 mm dia Bars @ 165 mm spacing bothways

i.e.0.363%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 165 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C25

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
239
F3-C25

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
11.951
919.776
6 1.2 (DL+LL+EQX)
-76.361 784.509
7 1.5 (DL+EQX)
-95.411
947.04
8 0.9DL+1.5EQX
-100.208 592.568
9 1.2 (DL+LL-EQX)
95.484
687.133
10 1.5 (DL-EQX)
119.395
825.32
11 0.9DL-1.5EQX
114.598 470.848
12 1.2 (DL+LL+EQZ)
9.725
781.496
13 1.5 (DL+EQZ)
12.197
943.273
14 0.9DL+1.5EQZ
7.4
588.801
15 1.2 (DL+LL-EQZ)
9.397
690.146
16 1.5 (DL-EQZ)
11.787
829.086
17 0.9DL-1.5EQZ
6.99
474.615

kN - m)
FORCE-Z
54.265
43.5
48.848
29.353
43.324
48.629
29.133
-45.726
-62.684
-82.179
132.55
160.161
140.665

MOM-X
42.945
34.458
38.829
23.348
34.254
38.573
23.093
-470.488
-592.354
-607.834
539.2
669.755
654.275

MOM-Y
-2.292
3.821
5.01
5.833
-7.488
-9.127
-8.303
0.749
1.17
1.994
-4.417
-5.287
-4.464

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 919.776 + 600.79


= 1520.566 kN

MOM Z
-14.816
172.475
215.591
221.519
-196.18
-245.227
-239.3
-12.153
-15.193
-9.266
-11.553
-14.443
-8.516

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1520.566 / (3.3 x 4.6 )


=

100.169

kN/m

Mxx/Zxx = 42.945 / 11.638


Mxx/Zxx =

3.691

kN/m

Mzz/Zzz = 14.816 / 8.349


Mzz/Zzz =

1.775

kN/m

Maxi.Soil Pressure pmax = 100.169 + 3.691 + 1.775


pmax =

105.64

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 100.169 - 3.691 - 1.775
pmin =

94.71

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
45.43
kN.m
Calculation of Stabilizing Moment
Due to External Load = 919.776 x 3.3 / 2
=
1517.64 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1517.64 + 0 + 375.71 + 615.6
=
2508.95 kN.m
F.O.S. against Overturning = 2508.95 / 45.43
= 55.2267 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

55.57

kN

Total Vertical Load = 1520.57 kN


F.O.S. against Sliding = 1520.566 x 0.5 / 55.57
= 13.69
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
239 5 1.5 (DL+LL)
919.776 60.5913
F3-C25 6 1.2 (DL+LL+EQX)
784.509 51.68043
0
7 1.5 (DL+EQX)
947.04 62.38735
0
8 0.9DL+1.5EQX
592.568 39.0361
0
9 1.2 (DL+LL-EQX)
687.133 45.26568
0
10 1.5 (DL-EQX)
825.32 54.36891
0
11 0.9DL-1.5EQX
470.848 31.01765
0
12 1.2 (DL+LL+EQZ)
781.496 51.48195
0
13 1.5 (DL+EQZ)
943.273 62.1392
0
14 0.9DL+1.5EQZ
588.801 38.78794
0
15 1.2 (DL+LL-EQZ)
690.146 45.46416
0
16 1.5 (DL-EQZ)
829.086 54.617
0
17 0.9DL-1.5EQZ
474.615 31.26581
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

3.7
2.97
3.34
2.01
2.95
3.32
1.99
40.43
50.9
52.23
46.34
57.55
56.22

1.78
20.66
25.83
26.54
23.5
29.38
28.67
1.46
1.82
1.11
1.39
1.73
1.03

66.0713
75.3104
91.5574
67.5861
71.7157
87.0689
61.6777
93.3719
114.859
92.1279
93.1942
113.897
88.5158

140
166
166
166
166
166
166
166
166
166
166
166
166

55.12
28.06
33.22
10.49
18.82
21.67
0.36
9.6
9.42
-14.56
-2.27
-4.67
-25.99

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 66.0713 kN/m2
pmax = 114.8592 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
239 5 1.5 (DL+LL)
60.5913
3.7
F3-C25 6 1.2 (DL+LL+EQX)
51.68043
2.97
0
7 1.5 (DL+EQX)
62.38735
3.34
0
8 0.9DL+1.5EQX
39.0361
2.01
0
9 1.2 (DL+LL-EQX)
45.26568
2.95
0
10 1.5 (DL-EQX)
54.36891
3.32
0
11 0.9DL-1.5EQX
31.01765
1.99
0
12 1.2 (DL+LL+EQZ)
51.48195 40.43
0
13 1.5 (DL+EQZ)
62.1392
50.9
0
14 0.9DL+1.5EQZ
38.78794 52.23
0
15 1.2 (DL+LL-EQZ)
45.46416 46.34
0
16 1.5 (DL-EQZ)
54.617 57.55
0
17 0.9DL-1.5EQZ
31.26581 56.22
Joint

kN/m2

Mzz/Zzz
(3)
1.78
20.66
25.83
26.54
23.5
29.38
28.67
1.46
1.82
1.11
1.39
1.73
1.03

pmin =

1+2+3

1-2+3

-25.99 kN/m2

1-2-3

66.072 58.672
55.112
75.311 69.371
28.051
91.558 84.878
33.218
67.587 63.567
10.487
71.716 65.816
18.816
87.069 80.429
21.669
61.678 57.698
0.358
93.372 12.512
9.592
114.86
13.06
9.42
92.128 -12.333 -14.553
93.195
0.515
-2.266
113.897 -1.204
-4.664
88.516 -23.925 -25.985

1+2-3
62.512
33.991
39.898
14.507
24.716
28.309
4.338
90.452
111.22
89.908
90.415
110.44
86.456

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
239 5 1.5 (DL+LL)
1520.566 100.169
F3-C25 6 1.2 (DL+LL+EQX)
1385.299 91.25817
0
7 1.5 (DL+EQX)
1547.83 101.9651
0
8 0.9DL+1.5EQX
1193.358 78.61383
0
9 1.2 (DL+LL-EQX)
1287.923 84.84341
0
10 1.5 (DL-EQX)
1426.11 93.94664
0
11 0.9DL-1.5EQX
1071.638 70.59539
0
12 1.2 (DL+LL+EQZ)
1382.286 91.05968
0
13 1.5 (DL+EQZ)
1544.063 101.7169
0
14 0.9DL+1.5EQZ
1189.591 78.36568
0
15 1.2 (DL+LL-EQZ)
1290.936 85.0419
0
16 1.5 (DL-EQZ)
1429.876 94.19473
0
17 0.9DL-1.5EQZ
1075.405 70.84354
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

3.7
2.97
3.34
2.01
2.95
3.32
1.99
40.43
50.9
52.23
46.34
57.55
56.22

1.78
20.66
25.83
26.54
23.5
29.38
28.67
1.46
1.82
1.11
1.39
1.73
1.03

105.649
114.888
131.135
107.164
111.293
126.647
101.255
132.95
154.437
131.706
132.772
153.475
128.094

140
166
166
166
166
166
166
166
166
166
166
166
166

94.69
67.63
72.8
50.07
58.4
61.25
39.94
49.17
49
25.03
37.32
34.92
13.6

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 105.649 kN/m2
pmax = 154.4369 kN/m2
pmin =

94.69 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
239 5 1.5 (DL+LL)
100.169
3.7
F3-C25 6 1.2 (DL+LL+EQX)
91.25817
2.97
0
7 1.5 (DL+EQX)
101.9651
3.34
0
8 0.9DL+1.5EQX
78.61383
2.01
0
9 1.2 (DL+LL-EQX)
84.84341
2.95
0
10 1.5 (DL-EQX)
93.94664
3.32
0
11 0.9DL-1.5EQX
70.59539
1.99
0
12 1.2 (DL+LL+EQZ)
91.05968 40.43
0
13 1.5 (DL+EQZ)
101.7169
50.9
0
14 0.9DL+1.5EQZ
78.36568 52.23
0
15 1.2 (DL+LL-EQZ)
85.0419 46.34
0
16 1.5 (DL-EQZ)
94.19473 57.55
0
17 0.9DL-1.5EQZ
70.84354 56.22
Joint

Mzz/Zzz
(3)
1.78
20.66
25.83
26.54
23.5
29.38
28.67
1.46
1.82
1.11
1.39
1.73
1.03

pmin =

13.6

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

105.65
114.889
131.136
107.164
111.294
126.647
101.256
132.95
154.437
131.706
132.772
153.475
128.094

98.25
108.949
124.456
103.144
105.394
120.007
97.276
52.09
52.637
27.246
40.092
38.375
15.654

94.69
67.629
72.796
50.064
58.394
61.247
39.936
49.17
48.997
25.026
37.312
34.915
13.594

102.09
73.569
79.476
54.084
64.294
67.887
43.916
130.03
150.8
129.49
129.99
150.02
126.03

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
239
F3-C25
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
45.42892 991.31
6 1.2 (DL+LL+EQX)
175.8834 991.31
7 1.5 (DL+EQX)
219.0597 991.31
8 0.9DL+1.5EQX
222.746 991.31
9 1.2 (DL+LL-EQX)
199.148 991.31
10 1.5 (DL-EQX)
248.2421 991.31
11 0.9DL-1.5EQX
240.4117 991.31
12 1.2 (DL+LL+EQZ)
470.6449 991.31
13 1.5 (DL+EQZ)
592.5488 991.31
14 0.9DL+1.5EQZ
607.9046 991.31
15 1.2 (DL+LL-EQZ)
539.3238 991.31
16 1.5 (DL-EQZ)
669.9107 991.31
17 0.9DL-1.5EQZ
654.3304 991.31

1517.64
1294.44
1562.62
977.74
1133.77
1361.78
776.9
1289.47
1556.41
971.53
1138.75
1368
783.12

55.23
13
11.66
8.84
10.68
9.48
7.36
4.85
4.3
3.23
3.95
3.53
2.72

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
55.56543
87.88204
107.1886
104.4186
104.8531
128.9184
118.2431
46.74872
63.85962
82.5115
132.8827
160.5941
140.8386

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.342

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1520.6
1385.3
1547.8
1193.4
1287.9
1426.1
1071.6
1382.3
1544.1
1189.6
1290.9
1429.9
1075.4

13.69
7.89
7.23
5.72
6.15
5.54
4.54
14.79
12.09
7.21
4.86
4.46
3.82

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column =
947.04 kN
Punching Shear,P =
947.04 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 865.51 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 865510


=
1.37 x4600
= 137.34 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
154.437

kN/m2

B) One Way Shear


1400
0

1925

153.33

kN/m2

152.914

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

52.637

kN/m2
111.25 kN/m2

154.437

kN/m2

127.445

kN/m2

150.797

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

At Length
Maximum Pressure = 127.445 - 25 x 0.6 - 18 x ( 2 - 0.6 )
87.245 kN/m2
-- For without Buoynacy Condition With Stress Increse
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 87.245 x 3.3 x 1.4
= 403.0719 kN
At Width
Maximum Pressure = 153.33 - 25 x 0.6 - 18 x ( 2 - 0.6 )
113.13 kN/m2
-- For without Buoynacy Condition With Stress Increse
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 113.13 x 4.6 x 0.875
= 455.3483 kN
Designed Shear Strength = 455.34825 kN
Corresponding Length =
4600
mm
% Ast =

0.342

Allowable Shear Stress =


0.4168 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4168 x 1
2

=
0.4168 N/mm
Depth Required = 455348.25
0.4168 x 4600
=
313
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 154.437
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
114.857 kN/m2
1.925

Bending Moment = 114.857 x 1.925 x 1.925 / 2


= 212.81 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1767.19
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
177
175

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1794.29

mm

Provide 20 mm dia Bars @ 175 mm spacing bothways

i.e.0.342%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 175 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.8
4.7
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.975

Wp

1.975
Z

1.65

Lp

F4

COLUMN NO.

C26

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.65

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.8 x 4.7 x 0.6
=
267.9
kN
Buoyant Self wt. of Fdn = 0 x 3.8 x 4.7 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.8 x 4.7) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
440.622 kN
Buoyant weight of Soil = [(3.8 x 4.7) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 267.9 + 0 + 440.622


=
708.52 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
283
F4-C26

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-10.805 1018.46
6 1.2 (DL+LL+EQX)
-89.48
817.644
7 1.5 (DL+EQX)
-111.836 983.351
8 0.9DL+1.5EQX
-107.52 591.448
9 1.2 (DL+LL-EQX)
72.191
811.892
10 1.5 (DL-EQX)
90.253
976.162
11 0.9DL-1.5EQX
94.569
584.259
12 1.2 (DL+LL+EQZ)
-8.657
857.6
13 1.5 (DL+EQZ)
-10.807
1033.3
14 0.9DL+1.5EQZ
-6.491
641.394
15 1.2 (DL+LL-EQZ)
-8.632
771.936
16 1.5 (DL-EQZ)
-10.776 926.216
17 0.9DL-1.5EQZ
-6.459
534.313

kN - m)
FORCE-Z
-94.431
-75.756
-84.754
-50.958
-75.334
-84.226
-50.43
-170.99
-203.79
-170
19.898
34.814
68.61

MOM-X
-274.939
-220.5
-247.351
-148.685
-219.403
-245.981
-147.315
-747.668
-906.312
-807.646
307.765
412.98
511.646

MOM-Y
11.155
15.973
19.062
14.962
1.875
1.439
-2.661
7.19
8.083
3.983
10.658
12.418
8.318

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.8 x 4.7
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

17.86

m2

1/6 x 3.8 x 4.7 x 4.7


13.991

m3

1/6 x 4.7 x 3.8 x 3.8


11.312

m3

Total Vertical Load P = 1018.46 + 708.52


= 1726.98 kN

MOM Z
10.934
187.41
234.269
229.893
-169.915
-212.386
-216.763
8.795
11.002
6.625
8.7
10.882
6.505

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1726.98 / (3.8 x 4.7 )


=

96.695

kN/m

Mxx/Zxx = 274.939 / 13.991


Mxx/Zxx =

19.652

kN/m

Mzz/Zzz = 10.934 / 11.312


Mzz/Zzz =

0.967

kN/m

Maxi.Soil Pressure pmax = 96.695 + 19.652 + 0.967


pmax =

117.32

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 96.695 - 19.652 - 0.967
pmin =

76.08

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
275.16 kN.m
Calculation of Stabilizing Moment
Due to External Load = 1018.46 x 3.8 / 2
=
1935.08 kN.m
Due to wt. of Pedestral = 0 x 1.9
=
0

kN.m

Due to Self Wt. of Fdn = 267.9 x 1.9


=
509.01 kN.m
Due to Wt. of Soil = 440.622 x 1.9
=
837.19 kN.m
Total Stabilizing moment = 1935.08 + 0 + 509.01 + 837.19
=
3281.28 kN.m
F.O.S. against Overturning = 3281.28 / 275.16
= 11.925 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

95.05

kN

Total Vertical Load = 1726.98 kN


F.O.S. against Sliding = 1726.98 x 0.5 / 95.05
=
9.09
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
283 5 1.5 (DL+LL)
1018.46 57.02464
F4-C26 6 1.2 (DL+LL+EQX)
817.644 45.78074
0
7 1.5 (DL+EQX)
983.351 55.05885
0
8 0.9DL+1.5EQX
591.448 33.11579
0
9 1.2 (DL+LL-EQX)
811.892 45.45868
0
10 1.5 (DL-EQX)
976.162 54.65633
0
11 0.9DL-1.5EQX
584.259 32.71327
0
12 1.2 (DL+LL+EQZ)
857.6 48.01792
0
13 1.5 (DL+EQZ)
1033.297 57.85538
0
14 0.9DL+1.5EQZ
641.394 35.91232
0
15 1.2 (DL+LL-EQZ)
771.936 43.2215
0
16 1.5 (DL-EQZ)
926.216 51.8598
0
17 0.9DL-1.5EQZ
534.313 29.91674
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

19.66
15.77
17.68
10.63
15.69
17.59
10.53
53.44
64.78
57.73
22
29.52
36.57

0.97
16.57
20.71
20.33
15.03
18.78
19.17
0.78
0.98
0.59
0.77
0.97
0.58

77.6546
78.1207
93.4488
64.0758
76.1787
91.0263
62.4133
102.238
123.615
94.2323
65.9915
82.3498
67.0667

140
166
166
166
166
166
166
166
166
166
166
166
166

36.4
13.45
16.67
2.16
14.74
18.29
3.02
-6.21
-7.91
-22.41
20.46
21.37
-7.24

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 77.65464 kN/m2
pmax = 123.6154 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
283 5 1.5 (DL+LL)
57.02464 19.66
F4-C26 6 1.2 (DL+LL+EQX)
45.78074 15.77
0
7 1.5 (DL+EQX)
55.05885 17.68
0
8 0.9DL+1.5EQX
33.11579 10.63
0
9 1.2 (DL+LL-EQX)
45.45868 15.69
0
10 1.5 (DL-EQX)
54.65633 17.59
0
11 0.9DL-1.5EQX
32.71327 10.53
0
12 1.2 (DL+LL+EQZ)
48.01792 53.44
0
13 1.5 (DL+EQZ)
57.85538 64.78
0
14 0.9DL+1.5EQZ
35.91232 57.73
0
15 1.2 (DL+LL-EQZ)
43.2215
22
0
16 1.5 (DL-EQZ)
51.8598 29.52
0
17 0.9DL-1.5EQZ
29.91674 36.57
Joint

kN/m2

Mzz/Zzz
(3)
0.97
16.57
20.71
20.33
15.03
18.78
19.17
0.78
0.98
0.59
0.77
0.97
0.58

pmin =

1+2+3

1-2+3

-22.41 kN/m2

1-2-3

1+2-3

77.655 38.335
36.395 75.715
78.121 46.581
13.441 44.981
93.449 58.089
16.669 52.029
64.076 42.816
2.156
23.416
76.179 44.799
14.739 46.119
91.027 55.847
18.287 53.467
62.414 41.354
3.014
24.074
102.238 -4.643
-6.203 100.68
123.616 -5.945
-7.905 121.66
94.233 -21.228 -22.408 93.053
65.992 21.992
20.452 64.452
82.35
23.31
21.37
80.41
67.067 -6.074
-7.234 65.907

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
283 5 1.5 (DL+LL)
1726.98 96.69541
F4-C26 6 1.2 (DL+LL+EQX)
1526.164 85.45151
0
7 1.5 (DL+EQX)
1691.871 94.72962
0
8 0.9DL+1.5EQX
1299.968 72.78656
0
9 1.2 (DL+LL-EQX)
1520.412 85.12945
0
10 1.5 (DL-EQX)
1684.682 94.3271
0
11 0.9DL-1.5EQX
1292.779 72.38404
0
12 1.2 (DL+LL+EQZ)
1566.12 87.68869
0
13 1.5 (DL+EQZ)
1741.817 97.52615
0
14 0.9DL+1.5EQZ
1349.914 75.58309
0
15 1.2 (DL+LL-EQZ)
1480.456 82.89227
0
16 1.5 (DL-EQZ)
1634.736 91.53057
0
17 0.9DL-1.5EQZ
1242.833 69.58751
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

19.66
15.77
17.68
10.63
15.69
17.59
10.53
53.44
64.78
57.73
22
29.52
36.57

0.97
16.57
20.71
20.33
15.03
18.78
19.17
0.78
0.98
0.59
0.77
0.97
0.58

117.325
117.792
133.12
103.747
115.849
130.697
102.084
141.909
163.286
133.903
105.662
122.021
106.738

140
166
166
166
166
166
166
166
166
166
166
166
166

76.07
53.12
56.34
41.83
54.41
57.96
42.69
33.47
31.77
17.27
60.13
61.05
32.44

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 117.3254 kN/m2
pmax = 163.2861 kN/m2
pmin =

76.07 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
283 5 1.5 (DL+LL)
96.69541 19.66
F4-C26 6 1.2 (DL+LL+EQX)
85.45151 15.77
0
7 1.5 (DL+EQX)
94.72962 17.68
0
8 0.9DL+1.5EQX
72.78656 10.63
0
9 1.2 (DL+LL-EQX)
85.12945 15.69
0
10 1.5 (DL-EQX)
94.3271 17.59
0
11 0.9DL-1.5EQX
72.38404 10.53
0
12 1.2 (DL+LL+EQZ)
87.68869 53.44
0
13 1.5 (DL+EQZ)
97.52615 64.78
0
14 0.9DL+1.5EQZ
75.58309 57.73
0
15 1.2 (DL+LL-EQZ)
82.89227
22
0
16 1.5 (DL-EQZ)
91.53057 29.52
0
17 0.9DL-1.5EQZ
69.58751 36.57
Joint

Mzz/Zzz
(3)
0.97
16.57
20.71
20.33
15.03
18.78
19.17
0.78
0.98
0.59
0.77
0.97
0.58

pmin =

17.27

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

117.326
117.792
133.12
103.747
115.85
130.698
102.085
141.909
163.287
133.904
105.663
122.021
106.738

78.006
86.252
97.76
82.487
84.47
95.518
81.025
35.029
33.727
18.444
61.663
62.981
33.598

76.066
53.112
56.34
41.827
54.41
57.958
42.685
33.469
31.767
17.264
60.123
61.041
32.438

115.39
84.652
91.7
63.087
85.79
93.138
63.745
140.35
161.33
132.72
104.12
120.08
105.58

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
283
F4-C26
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
275.1563 1346.2
6 1.2 (DL+LL+EQX)
289.3834 1346.2
7 1.5 (DL+EQX)
340.6824 1346.2
8 0.9DL+1.5EQX
273.7846 1346.2
9 1.2 (DL+LL-EQX)
277.5046 1346.2
10 1.5 (DL-EQX)
324.9838 1346.2
11 0.9DL-1.5EQX
262.0838 1346.2
12 1.2 (DL+LL+EQZ)
747.7197 1346.2
13 1.5 (DL+EQZ)
906.3788 1346.2
14 0.9DL+1.5EQZ
807.6732 1346.2
15 1.2 (DL+LL-EQZ)
307.8879 1346.2
16 1.5 (DL-EQZ)
413.1233 1346.2
17 0.9DL-1.5EQZ
511.6874 1346.2

1935.08
1553.53
1868.37
1123.76
1542.6
1854.71
1110.1
1629.44
1963.27
1218.65
1466.68
1759.82
1015.2

11.93
10.03
9.44
9.03
10.41
9.85
9.38
3.98
3.66
3.18
9.14
7.52
4.62

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
95.04716
117.2418
140.323
118.9843
104.3396
123.4489
107.175
171.207
204.0803
170.1219
21.68967
36.44361
68.91336

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3800
4700
525
0.386

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1727
1526.2
1691.9
1300
1520.4
1684.7
1292.8
1566.1
1741.8
1349.9
1480.5
1634.7
1242.8

9.09
6.51
6.03
5.47
7.29
6.83
6.04
4.58
4.27
3.97
34.13
22.43
9.02

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 1033.297 kN
Punching Shear,P =
1033.297 x (( 3.8 x 4.7 ) - ( 1.025 x 1.275 ))
( 3.8 * 4.7 )
P = 957.69 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 957690


=
1.37 x4600
= 151.97 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
163.287

kN/m2

B) One Way Shear


1450
0

1975

162.683

kN/m2

162.464

kN/m2

525

600

4700

750

500
200
1650
525

1125

3800

33.727

kN/m2
107.031 kN/m2

163.287

kN/m2

124.931

kN/m2

161.327

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 124.931 - 25 x 0.6 - 18 x ( 2 84.731 kN/m2
-- For without
Length at critical section =
3800
mm
Width at critical section =
1450
mm
Shear Force = 84.731 x 3.8 x 1.45
= 466.8678 kN
At Width
Maximum Pressure = 162.683 - 25 x 0.6 - 18 x ( 2 122.483 kN/m2
-- For without
Length at critical section =
4700
mm
Width at critical section =
1125
mm
Shear Force = 122.483 x 4.7 x 1.125
= 647.6289 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 647.62886 kN


Corresponding Length =
4700
mm
% Ast =

0.386

Allowable Shear Stress =


0.4376 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4376 x 1
2

=
0.4376 N/mm
Depth Required = 647628.86
0.4376 x 4700
=
390
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1650
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
472.73
Effe. Depth @ Critical s/c =
397.73
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 163.287
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 267.9 + 440.622 ) / ( 3.8 x 4.7 )
39.67
123.617 kN/m2
1.975

Bending Moment = 123.617 x 1.975 x 1.975 / 2


= 241.09 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

2015.88
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
155
155

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

2025.81

mm

Provide 20 mm dia Bars @ 155 mm spacing bothways

i.e.0.386%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 708.522 kN
Area Load = 708.522 / (3.8 x 4.7)

Maxi. Projection of fdn =

39.67

kN/m2

1.975

Bending Moment = 39.67 x 1.975 x 1.975 / 2


=
Ast =

77.37

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

622.79

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3800 mm


WIdth Of Footing :4700 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 155 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.8
4.7
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.975

Wp

1.975
Z

1.65

Lp

F4

COLUMN NO.

C27

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.65

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.8 x 4.7 x 0.6
=
267.9
kN
Buoyant Self wt. of Fdn = 0 x 3.8 x 4.7 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.8 x 4.7) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
440.622 kN
Buoyant weight of Soil = [(3.8 x 4.7) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 267.9 + 0 + 440.622


=
708.52 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
241
F4-C27

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-2.715
859.206
6 1.2 (DL+LL+EQX)
-87.084 643.979
7 1.5 (DL+EQX)
-108.916 770.153
8 0.9DL+1.5EQX
-107.805 440.399
9 1.2 (DL+LL-EQX)
82.739
730.75
10 1.5 (DL-EQX)
103.363 878.617
11 0.9DL-1.5EQX
104.473 548.863
12 1.2 (DL+LL+EQZ)
-2.284
725.702
13 1.5 (DL+EQZ)
-2.916
872.306
14 0.9DL+1.5EQZ
-1.806
542.552
15 1.2 (DL+LL-EQZ)
-2.06
649.028
16 1.5 (DL-EQZ)
-2.637
776.464
17 0.9DL-1.5EQZ
-1.527
446.71

kN - m)
FORCE-Z
-100.96
-80.443
-90.501
-54.137
-81.097
-91.318
-54.954
-169.19
-201.44
-165.07
7.652
19.618
55.982

MOM-X
-303.433
-242.457
-274.498
-164.554
-243.035
-275.22
-165.277
-720.91
-872.564
-762.62
235.418
322.846
432.79

MOM-Y
-2.212
4.001
5.228
6.022
-7.541
-9.199
-8.405
-7.005
-8.529
-7.735
3.465
4.558
5.352

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.8 x 4.7
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

17.86

m2

1/6 x 3.8 x 4.7 x 4.7


13.991

m3

1/6 x 4.7 x 3.8 x 3.8


11.312

m3

Total Vertical Load P = 859.206 + 708.52


= 1567.726 kN

MOM Z
1.975
184.886
231.174
230.357
-181.726
-227.091
-227.908
1.887
2.425
1.609
1.273
1.657
0.841

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1567.726 / (3.8 x 4.7 )


=

87.779

kN/m

Mxx/Zxx = 303.433 / 13.991


Mxx/Zxx =

21.688

kN/m

Mzz/Zzz = 1.975 / 11.312


Mzz/Zzz =

0.175

kN/m

Maxi.Soil Pressure pmax = 87.779 + 21.688 + 0.175


pmax =

109.65

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 87.779 - 21.688 - 0.175
pmin =

65.92

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
303.44 kN.m
Calculation of Stabilizing Moment
Due to External Load = 859.206 x 3.8 / 2
=
1632.5 kN.m
Due to wt. of Pedestral = 0 x 1.9
=
0

kN.m

Due to Self Wt. of Fdn = 267.9 x 1.9


=
509.01 kN.m
Due to Wt. of Soil = 440.622 x 1.9
=
837.19 kN.m
Total Stabilizing moment = 1632.5 + 0 + 509.01 + 837.19
=
2978.7 kN.m
F.O.S. against Overturning = 2978.7 / 303.44
= 9.81644 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

101

kN

Total Vertical Load = 1567.73 kN


F.O.S. against Sliding = 1567.726 x 0.5 / 101
=
7.77
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
241 5 1.5 (DL+LL)
859.206 48.10784
F4-C27 6 1.2 (DL+LL+EQX)
643.979 36.05705
0
7 1.5 (DL+EQX)
770.153 43.12167
0
8 0.9DL+1.5EQX
440.399 24.6584
0
9 1.2 (DL+LL-EQX)
730.75 40.91545
0
10 1.5 (DL-EQX)
878.617 49.19468
0
11 0.9DL-1.5EQX
548.863 30.73141
0
12 1.2 (DL+LL+EQZ)
725.702 40.63281
0
13 1.5 (DL+EQZ)
872.306 48.84132
0
14 0.9DL+1.5EQZ
542.552 30.37805
0
15 1.2 (DL+LL-EQZ)
649.028 36.33975
0
16 1.5 (DL-EQZ)
776.464 43.47503
0
17 0.9DL-1.5EQZ
446.71 25.01176
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

21.69
17.33
19.62
11.77
17.38
19.68
11.82
51.53
62.37
54.51
16.83
23.08
30.94

0.18
16.35
20.44
20.37
16.07
20.08
20.15
0.17
0.22
0.15
0.12
0.15
0.08

69.9778
69.7371
83.1817
56.7984
74.3655
88.9547
62.7014
92.3328
111.431
85.0381
53.2898
66.705
56.0318

140
166
166
166
166
166
166
166
166
166
166
166
166

26.24
2.38
3.07
-7.49
7.47
9.44
-1.24
-11.07
-13.75
-24.29
19.39
20.25
-6.01

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 69.97784 kN/m2
pmax = 111.4313 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
241 5 1.5 (DL+LL)
48.10784 21.69
F4-C27 6 1.2 (DL+LL+EQX)
36.05705 17.33
0
7 1.5 (DL+EQX)
43.12167 19.62
0
8 0.9DL+1.5EQX
24.6584 11.77
0
9 1.2 (DL+LL-EQX)
40.91545 17.38
0
10 1.5 (DL-EQX)
49.19468 19.68
0
11 0.9DL-1.5EQX
30.73141 11.82
0
12 1.2 (DL+LL+EQZ)
40.63281 51.53
0
13 1.5 (DL+EQZ)
48.84132 62.37
0
14 0.9DL+1.5EQZ
30.37805 54.51
0
15 1.2 (DL+LL-EQZ)
36.33975 16.83
0
16 1.5 (DL-EQZ)
43.47503 23.08
0
17 0.9DL-1.5EQZ
25.01176 30.94
Joint

kN/m2

Mzz/Zzz
(3)
0.18
16.35
20.44
20.37
16.07
20.08
20.15
0.17
0.22
0.15
0.12
0.15
0.08

pmin =

1+2+3

1-2+3

-24.29 kN/m2

1-2-3

1+2-3

69.978 26.598
26.238 69.618
69.738 35.078
2.378
37.038
83.182 43.942
3.062
42.302
56.799 33.259
-7.482 16.059
74.366 39.606
7.466
42.226
88.955 49.595
9.435
48.795
62.702 39.062
-1.239 22.402
92.333 -10.728 -11.068 91.993
111.432 -13.309 -13.749 110.99
85.039 -23.982 -24.282 84.739
53.29
19.63
19.39
53.05
66.706 20.546
20.246 66.406
56.032 -5.849
-6.009 55.872

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
241 5 1.5 (DL+LL)
1567.726 87.77861
F4-C27 6 1.2 (DL+LL+EQX)
1352.499 75.72783
0
7 1.5 (DL+EQX)
1478.673 82.79244
0
8 0.9DL+1.5EQX
1148.919 64.32917
0
9 1.2 (DL+LL-EQX)
1439.27 80.58623
0
10 1.5 (DL-EQX)
1587.137 88.86545
0
11 0.9DL-1.5EQX
1257.383 70.40218
0
12 1.2 (DL+LL+EQZ)
1434.222 80.30358
0
13 1.5 (DL+EQZ)
1580.826 88.51209
0
14 0.9DL+1.5EQZ
1251.072 70.04882
0
15 1.2 (DL+LL-EQZ)
1357.548 76.01053
0
16 1.5 (DL-EQZ)
1484.984 83.1458
0
17 0.9DL-1.5EQZ
1155.23 64.68253
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

21.69
17.33
19.62
11.77
17.38
19.68
11.82
51.53
62.37
54.51
16.83
23.08
30.94

0.18
16.35
20.44
20.37
16.07
20.08
20.15
0.17
0.22
0.15
0.12
0.15
0.08

109.649
109.408
122.852
96.4692
114.036
128.625
102.372
132.004
151.102
124.709
92.9605
106.376
95.7025

140
166
166
166
166
166
166
166
166
166
166
166
166

65.91
42.05
42.74
32.19
47.14
49.11
38.44
28.61
25.93
15.39
59.07
59.92
33.67

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 109.6486 kN/m2
pmax = 151.1021 kN/m2
pmin =

65.91 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
241 5 1.5 (DL+LL)
87.77861 21.69
F4-C27 6 1.2 (DL+LL+EQX)
75.72783 17.33
0
7 1.5 (DL+EQX)
82.79244 19.62
0
8 0.9DL+1.5EQX
64.32917 11.77
0
9 1.2 (DL+LL-EQX)
80.58623 17.38
0
10 1.5 (DL-EQX)
88.86545 19.68
0
11 0.9DL-1.5EQX
70.40218 11.82
0
12 1.2 (DL+LL+EQZ)
80.30358 51.53
0
13 1.5 (DL+EQZ)
88.51209 62.37
0
14 0.9DL+1.5EQZ
70.04882 54.51
0
15 1.2 (DL+LL-EQZ)
76.01053 16.83
0
16 1.5 (DL-EQZ)
83.1458 23.08
0
17 0.9DL-1.5EQZ
64.68253 30.94
Joint

Mzz/Zzz
(3)
0.18
16.35
20.44
20.37
16.07
20.08
20.15
0.17
0.22
0.15
0.12
0.15
0.08

pmin =

15.39

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

109.649
109.408
122.853
96.47
114.037
128.626
102.373
132.004
151.103
124.709
92.961
106.376
95.703

66.269
74.748
83.613
72.93
79.277
89.266
78.733
28.944
26.363
15.689
59.301
60.216
33.823

65.909
42.048
42.733
32.19
47.137
49.106
38.433
28.604
25.923
15.389
59.061
59.916
33.663

109.29
76.708
81.973
55.73
81.897
88.466
62.073
131.66
150.66
124.41
92.721
106.08
95.543

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
241
F4-C27
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
303.4394 1346.2
6 1.2 (DL+LL+EQX)
304.9069 1346.2
7 1.5 (DL+EQX)
358.874 1346.2
8 0.9DL+1.5EQX
283.0943 1346.2
9 1.2 (DL+LL-EQX)
303.4639 1346.2
10 1.5 (DL-EQX)
356.8142 1346.2
11 0.9DL-1.5EQX
281.5289 1346.2
12 1.2 (DL+LL+EQZ)
720.9125 1346.2
13 1.5 (DL+EQZ)
872.5674 1346.2
14 0.9DL+1.5EQZ
762.6217 1346.2
15 1.2 (DL+LL-EQZ)
235.4214 1346.2
16 1.5 (DL-EQZ)
322.8503 1346.2
17 0.9DL-1.5EQZ
432.7908 1346.2

1632.5
1223.57
1463.3
836.76
1388.43
1669.38
1042.84
1378.84
1657.39
1030.85
1233.16
1475.29
848.75

9.82
8.43
7.83
7.72
9.02
8.46
8.49
3.78
3.45
3.12
10.96
8.74
5.08

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
100.9985
118.5525
141.6091
120.6347
115.8554
137.9235
118.0447
169.2074
201.4571
165.0829
7.924437
19.79444
56.00282

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3800
4700
525
0.352

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1567.7
1352.5
1478.7
1148.9
1439.3
1587.1
1257.4
1434.2
1580.8
1251.1
1357.5
1485
1155.2

7.77
5.71
5.23
4.77
6.22
5.76
5.33
4.24
3.93
3.79
85.66
37.52
10.32

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 878.617 kN
Punching Shear,P =
878.617 x (( 3.8 x 4.7 ) - ( 1.025 x 1.275 ))
( 3.8 * 4.7 )
P = 814.33 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 814330


=
1.37 x4600
= 129.22 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
151.103

kN/m2

B) One Way Shear


1450
0

1975

150.968

kN/m2

150.919

kN/m2

525

600

4700

750

500
200
1650
525

1125

3800

26.363

kN/m2
96.94 kN/m2

151.103

kN/m2

114.174

kN/m2

150.663

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 114.174 - 25 x 0.6 - 18 x ( 2 73.974 kN/m2
-- For without
Length at critical section =
3800
mm
Width at critical section =
1450
mm
Shear Force = 73.974 x 3.8 x 1.45
= 407.5967 kN
At Width
Maximum Pressure = 150.968 - 25 x 0.6 - 18 x ( 2 110.768 kN/m2
-- For without
Length at critical section =
4700
mm
Width at critical section =
1125
mm
Shear Force = 110.768 x 4.7 x 1.125
= 585.6858 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 585.6858 kN


Corresponding Length =
4700
mm
% Ast =

0.352

Allowable Shear Stress =


0.422
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.422 x 1
2

N/mm
=
0.422
Depth Required = 585685.8
0.422 x 4700
=
371
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1650
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
472.73
Effe. Depth @ Critical s/c =
397.73
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 151.103
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 267.9 + 440.622 ) / ( 3.8 x 4.7 )
39.67
111.433 kN/m2
1.975

Bending Moment = 111.433 x 1.975 x 1.975 / 2


= 217.33 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1806.69
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
173
170

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1847.06

mm

Provide 20 mm dia Bars @ 170 mm spacing bothways

i.e.0.352%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 708.522 kN
Area Load = 708.522 / (3.8 x 4.7)

Maxi. Projection of fdn =

39.67

kN/m2

1.975

Bending Moment = 39.67 x 1.975 x 1.975 / 2


=
Ast =

77.37

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

622.79

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3800 mm


WIdth Of Footing :4700 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 170 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C28

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
242
F3-C28

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
0.932
783.66
6 1.2 (DL+LL+EQX)
-87.761 629.605
7 1.5 (DL+EQX)
-109.587 757.231
8 0.9DL+1.5EQX
-110.006 455.677
9 1.2 (DL+LL-EQX)
89.252
624.251
10 1.5 (DL-EQX)
111.678 750.539
11 0.9DL-1.5EQX
111.26
448.985
12 1.2 (DL+LL+EQZ)
0.513
662.146
13 1.5 (DL+EQZ)
0.756
797.907
14 0.9DL+1.5EQZ
0.338
496.353
15 1.2 (DL+LL-EQZ)
0.977
591.711
16 1.5 (DL-EQZ)
1.335
709.863
17 0.9DL-1.5EQZ
0.917
408.309

kN - m)
FORCE-Z
-86.503
-68.349
-76.801
-45.654
-70.057
-78.936
-47.788
-150.49
-179.48
-148.34
12.088
23.746
54.893

MOM-X
-252.127
-199.512
-225.035
-133.926
-203.892
-230.509
-139.4
-643.226
-779.677
-688.568
239.822
324.133
415.241

MOM-Y
-6.226
-0.535
-0.254
2.071
-9.427
-11.37
-9.045
-12.52
-15.24
-12.91
2.558
3.612
5.936

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 783.66 + 600.79


= 1384.45 kN

MOM Z
-2.088
185.728
232.019
232.911
-189.069
-236.478
-235.586
-1.122
-1.544
-0.652
-2.219
-2.915
-2.023

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1384.45 / (3.3 x 4.6 )


=

91.202

kN/m

Mxx/Zxx = 252.127 / 11.638


Mxx/Zxx =

21.665

kN/m

Mzz/Zzz = 2.088 / 8.349


Mzz/Zzz =

0.251

kN/m

Maxi.Soil Pressure pmax = 91.202 + 21.665 + 0.251


pmax =

113.12

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 91.202 - 21.665 - 0.251
pmin =

69.29

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
252.14 kN.m
Calculation of Stabilizing Moment
Due to External Load = 783.66 x 3.3 / 2
=
1293.04 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1293.04 + 0 + 375.71 + 615.6
=
2284.35 kN.m
F.O.S. against Overturning = 2284.35 / 252.14
= 9.05985 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

86.51

kN

Total Vertical Load = 1384.45 kN


F.O.S. against Sliding = 1384.45 x 0.5 / 86.51
=
8.01
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
242 5 1.5 (DL+LL)
783.66 51.62451
F3-C28 6 1.2 (DL+LL+EQX)
629.605 41.47596
0
7 1.5 (DL+EQX)
757.231 49.88347
0
8 0.9DL+1.5EQX
455.677 30.01825
0
9 1.2 (DL+LL-EQX)
624.251 41.12325
0
10 1.5 (DL-EQX)
750.539 49.44262
0
11 0.9DL-1.5EQX
448.985 29.5774
0
12 1.2 (DL+LL+EQZ)
662.146 43.61963
0
13 1.5 (DL+EQZ)
797.907 52.56304
0
14 0.9DL+1.5EQZ
496.353 32.69783
0
15 1.2 (DL+LL-EQZ)
591.711 38.97964
0
16 1.5 (DL-EQZ)
709.863 46.76304
0
17 0.9DL-1.5EQZ
408.309 26.89783
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

21.67
17.15
19.34
11.51
17.52
19.81
11.98
55.27
67
59.17
20.61
27.86
35.68

0.26
22.25
27.8
27.9
22.65
28.33
28.22
0.14
0.19
0.08
0.27
0.35
0.25

73.5545
80.876
97.0235
69.4282
81.2933
97.5826
69.7774
99.0296
119.753
91.9478
59.8596
74.973
62.8278

140
166
166
166
166
166
166
166
166
166
166
166
166

29.7
2.08
2.75
-9.4
0.96
1.31
-10.63
-11.8
-14.63
-26.56
18.1
18.56
-9.04

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 73.55451 kN/m2
pmax = 119.753 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
242 5 1.5 (DL+LL)
51.62451 21.67
F3-C28 6 1.2 (DL+LL+EQX)
41.47596 17.15
0
7 1.5 (DL+EQX)
49.88347 19.34
0
8 0.9DL+1.5EQX
30.01825 11.51
0
9 1.2 (DL+LL-EQX)
41.12325 17.52
0
10 1.5 (DL-EQX)
49.44262 19.81
0
11 0.9DL-1.5EQX
29.5774 11.98
0
12 1.2 (DL+LL+EQZ)
43.61963 55.27
0
13 1.5 (DL+EQZ)
52.56304
67
0
14 0.9DL+1.5EQZ
32.69783 59.17
0
15 1.2 (DL+LL-EQZ)
38.97964 20.61
0
16 1.5 (DL-EQZ)
46.76304 27.86
0
17 0.9DL-1.5EQZ
26.89783 35.68
Joint

kN/m2

Mzz/Zzz
(3)
0.26
22.25
27.8
27.9
22.65
28.33
28.22
0.14
0.19
0.08
0.27
0.35
0.25

pmin =

1+2+3

1-2+3

-26.56 kN/m2

1-2-3

1+2-3

73.555 30.215
29.695 73.035
80.876 46.576
2.076
36.376
97.024 58.344
2.744
41.424
69.429 46.409
-9.392 13.629
81.294 46.254
0.954
35.994
97.583 57.963
1.303
40.923
69.778 45.818 -10.623 13.338
99.03 -11.511 -11.791 98.75
119.754 -14.247 -14.627 119.37
91.948 -26.393 -26.553 91.788
59.86
18.64
18.1
59.32
74.974 19.254
18.554 74.274
62.828 -8.533
-9.033 62.328

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
242 5 1.5 (DL+LL)
1384.45 91.20224
F3-C28 6 1.2 (DL+LL+EQX)
1230.395 81.05369
0
7 1.5 (DL+EQX)
1358.021 89.4612
0
8 0.9DL+1.5EQX
1056.467 69.59598
0
9 1.2 (DL+LL-EQX)
1225.041 80.70099
0
10 1.5 (DL-EQX)
1351.329 89.02036
0
11 0.9DL-1.5EQX
1049.775 69.15514
0
12 1.2 (DL+LL+EQZ)
1262.936 83.19736
0
13 1.5 (DL+EQZ)
1398.697 92.14078
0
14 0.9DL+1.5EQZ
1097.143 72.27556
0
15 1.2 (DL+LL-EQZ)
1192.501 78.55738
0
16 1.5 (DL-EQZ)
1310.653 86.34078
0
17 0.9DL-1.5EQZ
1009.099 66.47556
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

21.67
17.15
19.34
11.51
17.52
19.81
11.98
55.27
67
59.17
20.61
27.86
35.68

0.26
22.25
27.8
27.9
22.65
28.33
28.22
0.14
0.19
0.08
0.27
0.35
0.25

113.132
120.454
136.601
109.006
120.871
137.16
109.355
138.607
159.331
131.526
99.4374
114.551
102.406

140
166
166
166
166
166
166
166
166
166
166
166
166

69.28
41.66
42.33
30.19
40.54
40.89
28.96
27.79
24.96
13.03
57.68
58.14
30.55

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 113.1322 kN/m2
pmax = 159.3308 kN/m2
pmin =

69.28 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
242 5 1.5 (DL+LL)
91.20224 21.67
F3-C28 6 1.2 (DL+LL+EQX)
81.05369 17.15
0
7 1.5 (DL+EQX)
89.4612 19.34
0
8 0.9DL+1.5EQX
69.59598 11.51
0
9 1.2 (DL+LL-EQX)
80.70099 17.52
0
10 1.5 (DL-EQX)
89.02036 19.81
0
11 0.9DL-1.5EQX
69.15514 11.98
0
12 1.2 (DL+LL+EQZ)
83.19736 55.27
0
13 1.5 (DL+EQZ)
92.14078
67
0
14 0.9DL+1.5EQZ
72.27556 59.17
0
15 1.2 (DL+LL-EQZ)
78.55738 20.61
0
16 1.5 (DL-EQZ)
86.34078 27.86
0
17 0.9DL-1.5EQZ
66.47556 35.68
Joint

Mzz/Zzz
(3)
0.26
22.25
27.8
27.9
22.65
28.33
28.22
0.14
0.19
0.08
0.27
0.35
0.25

pmin =

13.03

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

113.133
120.454
136.602
109.006
120.871
137.161
109.356
138.608
159.331
131.526
99.438
114.551
102.406

69.793
86.154
97.922
85.986
85.831
97.541
85.396
28.068
25.331
13.186
58.218
58.831
31.046

69.273
41.654
42.322
30.186
40.531
40.881
28.956
27.788
24.951
13.026
57.678
58.131
30.546

112.61
75.954
81.002
53.206
75.571
80.501
52.916
138.33
158.95
131.37
98.898
113.85
101.91

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
242
F3-C28
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
252.1356 991.31
6 1.2 (DL+LL+EQX)
272.5801 991.31
7 1.5 (DL+EQX)
323.2237 991.31
8 0.9DL+1.5EQX
268.6703 991.31
9 1.2 (DL+LL-EQX)
278.063 991.31
10 1.5 (DL-EQX)
330.2366 991.31
11 0.9DL-1.5EQX
273.7392 991.31
12 1.2 (DL+LL+EQZ)
643.227 991.31
13 1.5 (DL+EQZ)
779.6785 991.31
14 0.9DL+1.5EQZ
688.5683 991.31
15 1.2 (DL+LL-EQZ)
239.8323 991.31
16 1.5 (DL-EQZ)
324.1461 991.31
17 0.9DL-1.5EQZ
415.2459 991.31

1293.04
1038.85
1249.44
751.87
1030.02
1238.39
740.83
1092.55
1316.55
818.99
976.33
1171.28
673.71

9.07
7.45
6.94
6.49
7.27
6.76
6.33
3.24
2.97
2.63
8.21
6.68
4.01

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
86.50802
111.2366
133.8197
119.1033
113.4632
136.7584
121.0887
150.4949
179.4836
148.3354
12.12742
23.7835
54.90066

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.352

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1384.5
1230.4
1358
1056.5
1225
1351.3
1049.8
1262.9
1398.7
1097.1
1192.5
1310.7
1009.1

8.01
5.54
5.08
4.44
5.4
4.95
4.34
4.2
3.9
3.7
49.17
27.56
9.2

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 797.907 kN
Punching Shear,P =
797.907 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 729.22 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 729220


=
1.37 x4600
= 115.71 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
159.331

kN/m2

B) One Way Shear


1400
0

1925

159.216

kN/m2

159.172

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

25.331

kN/m2
102.483 kN/m2

159.331

kN/m2

123.801

kN/m2

158.951

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 123.801 - 25 x 0.6 - 18 x ( 2 83.601 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 83.601 x 3.3 x 1.4
= 386.2366 kN
At Width
Maximum Pressure = 159.216 - 25 x 0.6 - 18 x ( 2 119.016 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 119.016 x 4.6 x 0.875
= 479.0394 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 479.0394 kN


Corresponding Length =
4600
mm
% Ast =

0.352

Allowable Shear Stress =


0.422
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.422 x 1
2

N/mm
=
0.422
Depth Required = 479039.4
0.422 x 4600
=
322
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 159.331
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
119.751 kN/m2
1.925

Bending Moment = 119.751 x 1.925 x 1.925 / 2


= 221.88 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1846.55
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
170
170

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1847.06

mm

Provide 20 mm dia Bars @ 170 mm spacing bothways

i.e.0.352%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 170 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3
4.2
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.725

Wp

1.725
Z

1.25

Lp

F5

COLUMN NO.

C29

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.25

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3 x 4.2 x 0.6
=
189
kN
Buoyant Self wt. of Fdn = 0 x 3 x 4.2 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3 x 4.2) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
308.07 kN
Buoyant weight of Soil = [(3 x 4.2) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 189 + 0 + 308.07


=
497.07 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
243
F5-C29

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-0.536
705.791
6 1.2 (DL+LL+EQX)
-90.597 526.263
7 1.5 (DL+EQX)
-113.259 635.058
8 0.9DL+1.5EQX
-113.039 361.85
9 1.2 (DL+LL-EQX)
89.739
603.002
10 1.5 (DL-EQX)
112.161 730.983
11 0.9DL-1.5EQX
112.381 457.774
12 1.2 (DL+LL+EQZ)
-0.516
595.278
13 1.5 (DL+EQZ)
-0.657
721.327
14 0.9DL+1.5EQZ
-0.438
448.119
15 1.2 (DL+LL-EQZ)
-0.342
533.987
16 1.5 (DL-EQZ)
-0.44
644.714
17 0.9DL-1.5EQZ
-0.221
371.506

kN - m)
FORCE-Z
-54.579
-38.808
-43.03
-23.39
-48.519
-55.169
-35.529
-108.36
-129.97
-110.34
21.036
31.775
51.415

MOM-X
-157.419
-112.731
-125.355
-68.611
-139.139
-158.365
-101.621
-477.289
-581.053
-524.309
225.419
297.333
354.077

MOM-Y
-9.901
-3.591
-3.554
0.033
-12.25
-14.38
-10.79
-26.94
-32.74
-29.15
11.097
14.806
18.393

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3 x 4.2
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

12.6

m2

1/6 x 3 x 4.2 x 4.2


8.82

m3

1/6 x 4.2 x 3 x 3
6.3

m3

Total Vertical Load P = 705.791 + 497.07


= 1202.861 kN

MOM Z
-0.327
189.051
236.302
236.438
-189.574
-236.98
-236.844
0.217
0.258
0.394
-0.739
-0.937
-0.801

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1202.861 / (3 x 4.2 )


=

95.465

kN/m

Mxx/Zxx = 157.419 / 8.82


Mxx/Zxx =

17.848

kN/m

Mzz/Zzz = 0.327 / 6.3


Mzz/Zzz =

0.052

kN/m

Maxi.Soil Pressure pmax = 95.465 + 17.848 + 0.052


pmax =

113.37

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 95.465 - 17.848 - 0.052
pmin =

77.57

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
157.42 kN.m
Calculation of Stabilizing Moment
Due to External Load = 705.791 x 3 / 2
=
1058.69 kN.m
Due to wt. of Pedestral = 0 x 1.5
=
0

kN.m

Due to Self Wt. of Fdn = 189 x 1.5


=
283.5
kN.m
Due to Wt. of Soil = 308.07 x 1.5
=
462.11 kN.m
Total Stabilizing moment = 1058.69 + 0 + 283.5 + 462.11
=
1804.3 kN.m
F.O.S. against Overturning = 1804.3 / 157.42
= 11.4617 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

54.59

kN

Total Vertical Load = 1202.86 kN


F.O.S. against Sliding = 1202.861 x 0.5 / 54.59
= 11.02
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
243 5 1.5 (DL+LL)
705.791 56.01516
F5-C29 6 1.2 (DL+LL+EQX)
526.263 41.7669
0
7 1.5 (DL+EQX)
635.058 50.40143
0
8 0.9DL+1.5EQX
361.85 28.71825
0
9 1.2 (DL+LL-EQX)
603.002 47.8573
0
10 1.5 (DL-EQX)
730.983 58.01452
0
11 0.9DL-1.5EQX
457.774 36.33127
0
12 1.2 (DL+LL+EQZ)
595.278 47.24429
0
13 1.5 (DL+EQZ)
721.327 57.24817
0
14 0.9DL+1.5EQZ
448.119 35.565
0
15 1.2 (DL+LL-EQZ)
533.987 42.37992
0
16 1.5 (DL-EQZ)
644.714 51.16778
0
17 0.9DL-1.5EQZ
371.506 29.4846
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

17.85
12.79
14.22
7.78
15.78
17.96
11.53
54.12
65.88
59.45
25.56
33.72
40.15

0.06
30.01
37.51
37.53
30.1
37.62
37.6
0.04
0.05
0.07
0.12
0.15
0.13

73.9252
84.5669
102.131
74.0283
93.7373
113.595
85.4613
101.404
123.178
95.085
68.0599
85.0378
69.7646

140
166
166
166
166
166
166
166
166
166
166
166
166

38.11
-1.04
-1.33
-16.6
1.98
2.44
-12.8
-6.92
-8.69
-23.96
16.7
17.3
-10.8

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 73.92516 kN/m2
pmax = 123.1782 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
243 5 1.5 (DL+LL)
56.01516 17.85
F5-C29 6 1.2 (DL+LL+EQX)
41.7669 12.79
0
7 1.5 (DL+EQX)
50.40143 14.22
0
8 0.9DL+1.5EQX
28.71825
7.78
0
9 1.2 (DL+LL-EQX)
47.8573 15.78
0
10 1.5 (DL-EQX)
58.01452 17.96
0
11 0.9DL-1.5EQX
36.33127 11.53
0
12 1.2 (DL+LL+EQZ)
47.24429 54.12
0
13 1.5 (DL+EQZ)
57.24817 65.88
0
14 0.9DL+1.5EQZ
35.565 59.45
0
15 1.2 (DL+LL-EQZ)
42.37992 25.56
0
16 1.5 (DL-EQZ)
51.16778 33.72
0
17 0.9DL-1.5EQZ
29.4846 40.15
Joint

kN/m2

Mzz/Zzz
(3)
0.06
30.01
37.51
37.53
30.1
37.62
37.6
0.04
0.05
0.07
0.12
0.15
0.13

pmin =

1+2+3

1-2+3

-23.96 kN/m2

1-2-3

73.926 38.226
38.106
84.567 58.987
-1.034
102.132 73.692
-1.329
74.029 58.469 -16.592
93.738 62.178
1.978
113.595 77.675
2.435
85.462 62.402 -12.799
101.405 -6.836
-6.916
123.179 -8.582
-8.682
95.085 -23.815 -23.955
68.06
16.94
16.7
85.038 17.598
17.298
69.765 -10.536 -10.796

1+2-3
73.806
24.547
27.112
-1.032
33.538
38.355
10.262
101.33
123.08
94.945
67.82
84.738
69.505

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
243 5 1.5 (DL+LL)
1202.861 95.46516
F5-C29 6 1.2 (DL+LL+EQX)
1023.333 81.2169
0
7 1.5 (DL+EQX)
1132.128 89.85143
0
8 0.9DL+1.5EQX
858.92 68.16825
0
9 1.2 (DL+LL-EQX)
1100.072 87.3073
0
10 1.5 (DL-EQX)
1228.053 97.46452
0
11 0.9DL-1.5EQX
954.844 75.78127
0
12 1.2 (DL+LL+EQZ)
1092.348 86.69429
0
13 1.5 (DL+EQZ)
1218.397 96.69817
0
14 0.9DL+1.5EQZ
945.189 75.015
0
15 1.2 (DL+LL-EQZ)
1031.057 81.82992
0
16 1.5 (DL-EQZ)
1141.784 90.61778
0
17 0.9DL-1.5EQZ
868.576 68.9346
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

17.85
12.79
14.22
7.78
15.78
17.96
11.53
54.12
65.88
59.45
25.56
33.72
40.15

0.06
30.01
37.51
37.53
30.1
37.62
37.6
0.04
0.05
0.07
0.12
0.15
0.13

113.375
124.017
141.581
113.478
133.187
153.045
124.911
140.854
162.628
134.535
107.51
124.488
109.215

140
166
166
166
166
166
166
166
166
166
166
166
166

77.56
38.42
38.13
22.86
41.43
41.89
26.66
32.54
30.77
15.5
56.15
56.75
28.66

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 113.3752 kN/m2
pmax = 162.6282 kN/m2
pmin =

77.56 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
243 5 1.5 (DL+LL)
95.46516 17.85
F5-C29 6 1.2 (DL+LL+EQX)
81.2169 12.79
0
7 1.5 (DL+EQX)
89.85143 14.22
0
8 0.9DL+1.5EQX
68.16825
7.78
0
9 1.2 (DL+LL-EQX)
87.3073 15.78
0
10 1.5 (DL-EQX)
97.46452 17.96
0
11 0.9DL-1.5EQX
75.78127 11.53
0
12 1.2 (DL+LL+EQZ)
86.69429 54.12
0
13 1.5 (DL+EQZ)
96.69817 65.88
0
14 0.9DL+1.5EQZ
75.015 59.45
0
15 1.2 (DL+LL-EQZ)
81.82992 25.56
0
16 1.5 (DL-EQZ)
90.61778 33.72
0
17 0.9DL-1.5EQZ
68.9346 40.15
Joint

Mzz/Zzz
(3)
0.06
30.01
37.51
37.53
30.1
37.62
37.6
0.04
0.05
0.07
0.12
0.15
0.13

pmin =

15.5

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

113.376
124.017
141.582
113.479
133.188
153.045
124.912
140.855
162.629
134.535
107.51
124.488
109.215

77.676
98.437
113.142
97.919
101.628
117.125
101.852
32.615
30.869
15.635
56.39
57.048
28.915

77.556
38.417
38.122
22.859
41.428
41.885
26.652
32.535
30.769
15.495
56.15
56.748
28.655

113.26
63.997
66.562
38.419
72.988
77.805
49.712
140.78
162.53
134.4
107.27
124.19
108.96

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
243
F5-C29
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
157.4193 745.61
6 1.2 (DL+LL+EQX)
220.1103 745.61
7 1.5 (DL+EQX)
267.493 745.61
8 0.9DL+1.5EQX
246.1918 745.61
9 1.2 (DL+LL-EQX)
235.1552 745.61
10 1.5 (DL-EQX)
285.0245 745.61
11 0.9DL-1.5EQX
257.7245 745.61
12 1.2 (DL+LL+EQZ)
477.289 745.61
13 1.5 (DL+EQZ)
581.0531 745.61
14 0.9DL+1.5EQZ
524.3091 745.61
15 1.2 (DL+LL-EQZ)
225.4202 745.61
16 1.5 (DL-EQZ)
297.3345 745.61
17 0.9DL-1.5EQZ
354.0779 745.61

1058.69
789.4
952.59
542.78
904.51
1096.48
686.67
892.92
1082
672.18
800.99
967.08
557.26

11.47
6.98
6.35
5.24
7.02
6.47
5.56
3.44
3.15
2.71
6.87
5.77
3.68

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
54.58163
98.559
121.1577
115.4336
102.0156
124.9948
117.8635
108.3642
129.9757
110.3359
21.03878
31.77805
51.41547

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3000
4200
525
0.294

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1202.9
1023.3
1132.1
858.92
1100.1
1228.1
954.84
1092.3
1218.4
945.19
1031.1
1141.8
868.58

11.02
5.2
4.68
3.73
5.4
4.92
4.06
5.05
4.69
4.29
24.51
17.97
8.45

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 730.983 kN
Punching Shear,P =
730.983 x (( 3 x 4.2 ) - ( 1.025 x 1.275 ))
( 3 * 4.2 )
P = 655.17 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 655170


=
1.37 x4600
= 103.96 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
162.629

kN/m2

B) One Way Shear


1200
0

1725

162.601

kN/m2

162.588

kN/m2

525

600

4200

750

500
200
1250
525

725

3000

30.869

kN/m2
107.729 kN/m2

162.629

kN/m2

130.787

kN/m2

162.529

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 130.787 - 25 x 0.6 - 18 x ( 2 90.587 kN/m2
-- For without
Length at critical section =
3000
mm
Width at critical section =
1200
mm
Shear Force = 90.587 x 3 x 1.2
= 326.1132 kN
At Width
Maximum Pressure = 162.601 - 25 x 0.6 - 18 x ( 2 122.401 kN/m2
-- For without
Length at critical section =
4200
mm
Width at critical section =
725
mm
Shear Force = 122.401 x 4.2 x 0.725
= 372.711 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 372.71105 kN


Corresponding Length =
4200
mm
% Ast =

0.294

Allowable Shear Stress =


0.3908 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.3908 x 1
2

=
0.3908 N/mm
Depth Required = 372711.05
0.3908 x 4200
=
303
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1250
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
432
Effe. Depth @ Critical s/c =
357
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 162.629
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 189 + 308.07 ) / ( 3 x 4.2 )
39.45
123.179 kN/m2
1.725

Bending Moment = 123.179 x 1.725 x 1.725 / 2


= 183.27 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

1511.19
0.2
1050
16
200.96
132
130

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1545.85

mm

Provide 16 mm dia Bars @ 130 mm spacing bothways

i.e.0.295%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
497.07 kN
Area Load = 497.07 / (3 x 4.2)

Maxi. Projection of fdn =

39.45

kN/m2

1.725

Bending Moment = 39.45 x 1.725 x 1.725 / 2


=
Ast =

58.69

kN.m

0.5 x fck x b x d

1 -

fy
470.5

mm2

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Ast =

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3000 mm


WIdth Of Footing :4200 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 130 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3
4.2
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.725

Wp

1.725
Z

1.25

Lp

F5

COLUMN NO.

C30

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.25

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3 x 4.2 x 0.6
=
189
kN
Buoyant Self wt. of Fdn = 0 x 3 x 4.2 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3 x 4.2) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
308.07 kN
Buoyant weight of Soil = [(3 x 4.2) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 189 + 0 + 308.07


=
497.07 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
244
F5-C30

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
7.273
801.107
6 1.2 (DL+LL+EQX)
-81.078 684.895
7 1.5 (DL+EQX)
-101.1
840.34
8 0.9DL+1.5EQX
-104.108 526.209
9 1.2 (DL+LL-EQX)
92.714
596.877
10 1.5 (DL-EQX)
116.14
730.317
11 0.9DL-1.5EQX
113.132 416.186
12 1.2 (DL+LL+EQZ)
5.636
748.729
13 1.5 (DL+EQZ)
7.292
920.133
14 0.9DL+1.5EQZ
4.284
606.002
15 1.2 (DL+LL-EQZ)
6
533.042
16 1.5 (DL-EQZ)
7.748
650.524
17 0.9DL-1.5EQZ
4.74
336.393

kN - m)
FORCE-Z
-28.281
-22.293
-28.518
-16.945
-22.956
-29.347
-17.774
-104.03
-130.69
-119.11
58.779
72.822
84.395

MOM-X
-36.656
-28.341
-35.79
-20.982
-30.308
-38.249
-23.441
-292.789
-366.35
-351.542
234.14
292.311
307.119

MOM-Y
-5.748
3.473
4.912
6.983
-12.67
-15.27
-13.2
-20.36
-24.88
-22.81
11.163
14.524
16.595

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3 x 4.2
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

12.6

m2

1/6 x 3 x 4.2 x 4.2


8.82

m3

1/6 x 4.2 x 3 x 3
6.3

m3

Total Vertical Load P = 801.107 + 497.07


= 1298.177 kN

MOM Z
-9.168
178.312
222.579
226.371
-192.981
-241.538
-237.746
-6.672
-8.652
-4.86
-7.996
-10.307
-6.515

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1298.177 / (3 x 4.2 )


=

103.03

kN/m

Mxx/Zxx = 36.656 / 8.82


Mxx/Zxx =

4.157

kN/m

Mzz/Zzz = 9.168 / 6.3


Mzz/Zzz =

1.456

kN/m

Maxi.Soil Pressure pmax = 103.03 + 4.157 + 1.456


pmax =

108.65

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 103.03 - 4.157 - 1.456
pmin =

97.42

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
37.79
kN.m
Calculation of Stabilizing Moment
Due to External Load = 801.107 x 3 / 2
=
1201.67 kN.m
Due to wt. of Pedestral = 0 x 1.5
=
0

kN.m

Due to Self Wt. of Fdn = 189 x 1.5


=
283.5
kN.m
Due to Wt. of Soil = 308.07 x 1.5
=
462.11 kN.m
Total Stabilizing moment = 1201.67 + 0 + 283.5 + 462.11
=
1947.28 kN.m
F.O.S. against Overturning = 1947.28 / 37.79
= 51.529 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

29.21

kN

Total Vertical Load = 1298.18 kN


F.O.S. against Sliding = 1298.177 x 0.5 / 29.21
= 22.23
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
244 5 1.5 (DL+LL)
801.107 63.57992
F5-C30 6 1.2 (DL+LL+EQX)
684.895 54.35675
0
7 1.5 (DL+EQX)
840.34 66.69365
0
8 0.9DL+1.5EQX
526.209 41.76262
0
9 1.2 (DL+LL-EQX)
596.877 47.37119
0
10 1.5 (DL-EQX)
730.317 57.96167
0
11 0.9DL-1.5EQX
416.186 33.03063
0
12 1.2 (DL+LL+EQZ)
748.729 59.42294
0
13 1.5 (DL+EQZ)
920.133 73.02643
0
14 0.9DL+1.5EQZ
606.002 48.0954
0
15 1.2 (DL+LL-EQZ)
533.042 42.30492
0
16 1.5 (DL-EQZ)
650.524 51.62889
0
17 0.9DL-1.5EQZ
336.393 26.69786
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

4.16
3.22
4.06
2.38
3.44
4.34
2.66
33.2
41.54
39.86
26.55
33.15
34.83

1.46
28.31
35.33
35.94
30.64
38.34
37.74
1.06
1.38
0.78
1.27
1.64
1.04

69.1999
85.8867
106.084
80.0826
81.4512
100.642
73.4306
93.6829
115.946
88.7354
70.1249
86.4189
62.5679

140
166
166
166
166
166
166
166
166
166
166
166
166

57.96
22.83
27.31
3.45
13.3
15.29
-7.37
25.17
30.11
7.46
14.49
16.84
-9.18

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 69.19992 kN/m2
pmax = 115.9464 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
244 5 1.5 (DL+LL)
63.57992
4.16
F5-C30 6 1.2 (DL+LL+EQX)
54.35675
3.22
0
7 1.5 (DL+EQX)
66.69365
4.06
0
8 0.9DL+1.5EQX
41.76262
2.38
0
9 1.2 (DL+LL-EQX)
47.37119
3.44
0
10 1.5 (DL-EQX)
57.96167
4.34
0
11 0.9DL-1.5EQX
33.03063
2.66
0
12 1.2 (DL+LL+EQZ)
59.42294
33.2
0
13 1.5 (DL+EQZ)
73.02643 41.54
0
14 0.9DL+1.5EQZ
48.0954 39.86
0
15 1.2 (DL+LL-EQZ)
42.30492 26.55
0
16 1.5 (DL-EQZ)
51.62889 33.15
0
17 0.9DL-1.5EQZ
26.69786 34.83
Joint

kN/m2

Mzz/Zzz
(3)
1.46
28.31
35.33
35.94
30.64
38.34
37.74
1.06
1.38
0.78
1.27
1.64
1.04

pmin =

-9.18

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

69.2
85.887
106.084
80.083
81.452
100.642
73.431
93.683
115.947
88.736
70.125
86.419
62.568

60.88
79.447
97.964
75.323
74.572
91.962
68.111
27.283
32.867
9.016
17.025
20.119
-7.093

57.96
22.827
27.304
3.443
13.292
15.282
-7.37
25.163
30.107
7.456
14.485
16.839
-9.173

66.28
29.267
35.424
8.203
20.172
23.962
-2.05
91.563
113.19
87.176
67.585
83.139
60.488

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
244 5 1.5 (DL+LL)
1298.177 103.0299
F5-C30 6 1.2 (DL+LL+EQX)
1181.965 93.80675
0
7 1.5 (DL+EQX)
1337.41 106.1437
0
8 0.9DL+1.5EQX
1023.279 81.21262
0
9 1.2 (DL+LL-EQX)
1093.947 86.82119
0
10 1.5 (DL-EQX)
1227.387 97.41167
0
11 0.9DL-1.5EQX
913.256 72.48063
0
12 1.2 (DL+LL+EQZ)
1245.799 98.87294
0
13 1.5 (DL+EQZ)
1417.203 112.4764
0
14 0.9DL+1.5EQZ
1103.072 87.5454
0
15 1.2 (DL+LL-EQZ)
1030.112 81.75492
0
16 1.5 (DL-EQZ)
1147.594 91.07889
0
17 0.9DL-1.5EQZ
833.463 66.14786
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

4.16
3.22
4.06
2.38
3.44
4.34
2.66
33.2
41.54
39.86
26.55
33.15
34.83

1.46
28.31
35.33
35.94
30.64
38.34
37.74
1.06
1.38
0.78
1.27
1.64
1.04

108.65
125.337
145.534
119.533
120.901
140.092
112.881
133.133
155.396
128.185
109.575
125.869
102.018

140
166
166
166
166
166
166
166
166
166
166
166
166

97.41
62.28
66.76
42.9
52.75
54.74
32.09
64.62
69.56
46.91
53.94
56.29
30.28

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 108.6499 kN/m2
pmax = 155.3964 kN/m2
pmin =

97.41 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
244 5 1.5 (DL+LL)
103.0299
4.16
F5-C30 6 1.2 (DL+LL+EQX)
93.80675
3.22
0
7 1.5 (DL+EQX)
106.1437
4.06
0
8 0.9DL+1.5EQX
81.21262
2.38
0
9 1.2 (DL+LL-EQX)
86.82119
3.44
0
10 1.5 (DL-EQX)
97.41167
4.34
0
11 0.9DL-1.5EQX
72.48063
2.66
0
12 1.2 (DL+LL+EQZ)
98.87294
33.2
0
13 1.5 (DL+EQZ)
112.4764 41.54
0
14 0.9DL+1.5EQZ
87.5454 39.86
0
15 1.2 (DL+LL-EQZ)
81.75492 26.55
0
16 1.5 (DL-EQZ)
91.07889 33.15
0
17 0.9DL-1.5EQZ
66.14786 34.83
Joint

Mzz/Zzz
(3)
1.46
28.31
35.33
35.94
30.64
38.34
37.74
1.06
1.38
0.78
1.27
1.64
1.04

pmin =

30.28

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

108.65
125.337
145.534
119.533
120.902
140.092
112.881
133.133
155.397
128.186
109.575
125.869
102.018

100.33
118.897
137.414
114.773
114.022
131.412
107.561
66.733
72.317
48.466
56.475
59.569
32.358

97.41
62.277
66.754
42.893
52.742
54.732
32.081
64.613
69.557
46.906
53.935
56.289
30.278

105.73
68.717
74.874
47.653
59.622
63.412
37.401
131.01
152.64
126.63
107.04
122.59
99.938

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
244
F5-C30
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
37.78511 745.61
6 1.2 (DL+LL+EQX)
180.5502 745.61
7 1.5 (DL+EQX)
225.4381 745.61
8 0.9DL+1.5EQX
227.3413 745.61
9 1.2 (DL+LL-EQX)
195.3465 745.61
10 1.5 (DL-EQX)
244.5477 745.61
11 0.9DL-1.5EQX
238.8988 745.61
12 1.2 (DL+LL+EQZ)
292.865 745.61
13 1.5 (DL+EQZ)
366.4522 745.61
14 0.9DL+1.5EQZ
351.5756 745.61
15 1.2 (DL+LL-EQZ)
234.2765 745.61
16 1.5 (DL-EQZ)
292.4927 745.61
17 0.9DL-1.5EQZ
307.1881 745.61

1201.67
1027.35
1260.51
789.32
895.32
1095.48
624.28
1123.1
1380.2
909.01
799.57
975.79
504.59

51.54
9.82
8.9
6.76
8.41
7.53
5.74
6.39
5.81
4.71
6.6
5.89
4.07

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
29.20122
84.08698
105.0452
105.478
95.51368
119.7904
114.5197
104.1806
130.8903
119.191
59.08444
73.23302
84.528

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3000
4200
525
0.273

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1298.2
1182
1337.4
1023.3
1093.9
1227.4
913.26
1245.8
1417.2
1103.1
1030.1
1147.6
833.46

22.23
7.03
6.37
4.86
5.73
5.13
3.99
5.98
5.42
4.63
8.72
7.84
4.94

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 920.133 kN
Punching Shear,P =
920.133 x (( 3 x 4.2 ) - ( 1.025 x 1.275 ))
( 3 * 4.2 )
P = 824.7 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 824700


=
1.37 x4600
= 130.86 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
155.397

kN/m2

B) One Way Shear


1200
0

1725

154.609

kN/m2

154.264

kN/m2

525

600

4200

750

500
200
1250
525

725

3000

72.317

kN/m2
120.781 kN/m2

155.397

kN/m2

135.32

kN/m2

152.637

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

At Length
Maximum Pressure = 135.32 - 25 x 0.6 - 18 x ( 2 - 0.6 )
95.12 kN/m2
-- For without Buoynacy Condition With Stress Increse
Length at critical section =
3000
mm
Width at critical section =
1200
mm
Shear Force = 95.12 x 3 x 1.2
= 342.432 kN
At Width
Maximum Pressure = 154.609 - 25 x 0.6 - 18 x ( 2 - 0.6 )
114.409 kN/m2
-- For without Buoynacy Condition With Stress Increse
Length at critical section =
4200
mm
Width at critical section =
725
mm
Shear Force = 114.409 x 4.2 x 0.725
= 348.3754 kN
Designed Shear Strength = 348.37541 kN
Corresponding Length =
4200
mm
% Ast =

0.273

Allowable Shear Stress =


0.3804 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.3804 x 1
2

=
0.3804 N/mm
Depth Required = 348375.41
0.3804 x 4200
=
294
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1250
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
432
Effe. Depth @ Critical s/c =
357
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 155.397
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 189 + 308.07 ) / ( 3 x 4.2 )
39.45
115.947 kN/m2
1.725

Bending Moment = 115.947 x 1.725 x 1.725 / 2


= 172.51 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

1418.87
0.2
1050
16
200.96
141
140

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1435.43

mm

Provide 16 mm dia Bars @ 140 mm spacing bothways

i.e.0.274%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
497.07 kN
Area Load = 497.07 / (3 x 4.2)

Maxi. Projection of fdn =

39.45

kN/m2

1.725

Bending Moment = 39.45 x 1.725 x 1.725 / 2


=
Ast =

58.69

kN.m

0.5 x fck x b x d

1 -

fy
470.5

mm2

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Ast =

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3000 mm


WIdth Of Footing :4200 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 140 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.1
3.1
0.5
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.175

Wp

1.175
Z

1.3

Lp

F6

COLUMN NO.

C31

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.3

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.1 x 3.1 x 0.5
=
120.13 kN
Buoyant Self wt. of Fdn = 0 x 3.1 x 3.1 x 0.5
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.1 x 3.1) - (0.5 x 0.75)] x (2 - 0.5 ) x 18


=
249.345 kN
Buoyant weight of Soil = [(3.1 x 3.1) - (0.5 x 0.75)] x (2 - 0.5 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 120.13 + 0 + 249.345


=
369.48 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
245
F6-C31

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-15.254 429.716
6 1.2 (DL+LL+EQX)
-69.984 445.801
7 1.5 (DL+EQX)
-87.635
550.41
8 0.9DL+1.5EQX
-81.471
381.26
9 1.2 (DL+LL-EQX)
45.577
241.745
10 1.5 (DL-EQX)
56.817
295.34
11 0.9DL-1.5EQX
62.98
126.19
12 1.2 (DL+LL+EQZ)
-12.524 428.924
13 1.5 (DL+EQZ)
-15.81
529.314
14 0.9DL+1.5EQZ
-9.646
360.164
15 1.2 (DL+LL-EQZ)
-11.883 258.622
16 1.5 (DL-EQZ)
-15.009 316.437
17 0.9DL-1.5EQZ
-8.845
147.286

kN - m)
FORCE-Z
-12.375
-10.426
-13.123
-8.137
-9.374
-11.808
-6.822
-53.425
-66.872
-61.886
33.625
41.941
46.927

MOM-X
-16.896
-14.806
-18.534
-11.765
-12.228
-15.312
-8.543
-147.173
-183.992
-177.223
120.138
150.146
156.916

MOM-Y
0.916
19.297
24.034
23.702
-17.83
-22.38
-22.71
-5.792
-7.327
-7.658
7.257
8.984
8.653

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.1 x 3.1
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

9.61

m2

1/6 x 3.1 x 3.1 x 3.1


4.966

m3

1/6 x 3.1 x 3.1 x 3.1


4.966

m3

Total Vertical Load P = 429.716 + 369.48


= 799.196 kN

MOM Z
16.486
165.71
207.25
200.611
-139.333
-174.054
-180.693
14.038
17.66
11.021
12.339
15.536
8.897

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 799.196 / (3.1 x 3.1 )


=

83.163

kN/m

Mxx/Zxx = 16.896 / 4.966


Mxx/Zxx =

3.403

kN/m

Mzz/Zzz = 16.486 / 4.966


Mzz/Zzz =

3.320

kN/m

Maxi.Soil Pressure pmax = 83.163 + 3.403 + 3.32


pmax =

89.89

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 83.163 - 3.403 - 3.32
pmin =

76.44

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
23.61
kN.m
Calculation of Stabilizing Moment
Due to External Load = 429.716 x 3.1 / 2
=
666.06 kN.m
Due to wt. of Pedestral = 0 x 1.55
=
0

kN.m

Due to Self Wt. of Fdn = 120.13 x 1.55


=
186.2
kN.m
Due to Wt. of Soil = 249.345 x 1.55
=
386.49 kN.m
Total Stabilizing moment = 666.06 + 0 + 186.2 + 386.49
=
1238.75 kN.m
F.O.S. against Overturning = 1238.75 / 23.61
= 52.4672 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

19.65

kN

Total Vertical Load = 799.196 kN


F.O.S. against Sliding = 799.196 x 0.5 / 19.65
= 20.34
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
245 5 1.5 (DL+LL)
429.716 44.7155
F6-C31 6 1.2 (DL+LL+EQX)
445.801 46.38928
0
7 1.5 (DL+EQX)
550.41 57.27471
0
8 0.9DL+1.5EQX
381.26 39.67326
0
9 1.2 (DL+LL-EQX)
241.745 25.15557
0
10 1.5 (DL-EQX)
295.34 30.73257
0
11 0.9DL-1.5EQX
126.19 13.13111
0
12 1.2 (DL+LL+EQZ)
428.924 44.63309
0
13 1.5 (DL+EQZ)
529.314 55.0795
0
14 0.9DL+1.5EQZ
360.164 37.47804
0
15 1.2 (DL+LL-EQZ)
258.622 26.91176
0
16 1.5 (DL-EQZ)
316.437 32.92789
0
17 0.9DL-1.5EQZ
147.286 15.32633
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

3.41
2.99
3.74
2.37
2.47
3.09
1.73
29.64
37.06
35.69
24.2
30.24
31.6

3.32
33.37
41.74
40.4
28.06
35.05
36.39
2.83
3.56
2.22
2.49
3.13
1.8

51.4455
82.7493
102.755
82.4433
55.6856
68.8726
51.2511
77.1031
95.6995
75.388
53.6018
66.2979
48.7263

140
166
166
166
166
166
166
166
166
166
166
166
166

37.99
10.03
11.8
-3.1
-5.38
-7.41
-24.99
12.17
14.46
-0.44
0.23
-0.45
-18.08

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 51.4455 kN/m2
pmax = 102.7547 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
245 5 1.5 (DL+LL)
44.7155
3.41
F6-C31 6 1.2 (DL+LL+EQX)
46.38928
2.99
0
7 1.5 (DL+EQX)
57.27471
3.74
0
8 0.9DL+1.5EQX
39.67326
2.37
0
9 1.2 (DL+LL-EQX)
25.15557
2.47
0
10 1.5 (DL-EQX)
30.73257
3.09
0
11 0.9DL-1.5EQX
13.13111
1.73
0
12 1.2 (DL+LL+EQZ)
44.63309 29.64
0
13 1.5 (DL+EQZ)
55.0795 37.06
0
14 0.9DL+1.5EQZ
37.47804 35.69
0
15 1.2 (DL+LL-EQZ)
26.91176
24.2
0
16 1.5 (DL-EQZ)
32.92789 30.24
0
17 0.9DL-1.5EQZ
15.32633
31.6
Joint

kN/m2

Mzz/Zzz
(3)
3.32
33.37
41.74
40.4
28.06
35.05
36.39
2.83
3.56
2.22
2.49
3.13
1.8

pmin =

1+2+3

1-2+3

-24.99 kN/m2

1-2-3

1+2-3

51.446 44.626
37.986 44.806
82.75
76.77
10.03
16.01
102.755 95.275
11.795 19.275
82.444 77.704
-3.097
1.644
55.686 50.746
-5.375 -0.435
68.873 62.693
-7.408 -1.228
51.252 47.792 -24.989 -21.53
77.104 17.824
12.164 71.444
95.7
21.58
14.46
88.58
75.389
4.009
-0.432 70.949
53.602
5.202
0.222
48.622
66.298
5.818
-0.443 60.038
48.727 -14.474 -18.074 45.127

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
245 5 1.5 (DL+LL)
799.196 83.16296
F6-C31 6 1.2 (DL+LL+EQX)
815.281 84.83673
0
7 1.5 (DL+EQX)
919.89 95.72216
0
8 0.9DL+1.5EQX
750.74 78.12071
0
9 1.2 (DL+LL-EQX)
611.225 63.60302
0
10 1.5 (DL-EQX)
664.82 69.18002
0
11 0.9DL-1.5EQX
495.67 51.57856
0
12 1.2 (DL+LL+EQZ)
798.404 83.08054
0
13 1.5 (DL+EQZ)
898.794 93.52695
0
14 0.9DL+1.5EQZ
729.644 75.92549
0
15 1.2 (DL+LL-EQZ)
628.102 65.35921
0
16 1.5 (DL-EQZ)
685.917 71.37534
0
17 0.9DL-1.5EQZ
516.766 53.77378
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

3.41
2.99
3.74
2.37
2.47
3.09
1.73
29.64
37.06
35.69
24.2
30.24
31.6

3.32
33.37
41.74
40.4
28.06
35.05
36.39
2.83
3.56
2.22
2.49
3.13
1.8

89.893
121.197
141.202
120.891
94.133
107.32
89.6986
115.551
134.147
113.835
92.0492
104.745
87.1738

140
166
166
166
166
166
166
166
166
166
166
166
166

76.44
48.48
50.25
35.36
33.08
31.05
13.46
50.62
52.91
38.02
38.67
38.01
20.38

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 89.89296 kN/m2
pmax = 141.2022 kN/m2
pmin =

76.44 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
245 5 1.5 (DL+LL)
83.16296
3.41
F6-C31 6 1.2 (DL+LL+EQX)
84.83673
2.99
0
7 1.5 (DL+EQX)
95.72216
3.74
0
8 0.9DL+1.5EQX
78.12071
2.37
0
9 1.2 (DL+LL-EQX)
63.60302
2.47
0
10 1.5 (DL-EQX)
69.18002
3.09
0
11 0.9DL-1.5EQX
51.57856
1.73
0
12 1.2 (DL+LL+EQZ)
83.08054 29.64
0
13 1.5 (DL+EQZ)
93.52695 37.06
0
14 0.9DL+1.5EQZ
75.92549 35.69
0
15 1.2 (DL+LL-EQZ)
65.35921
24.2
0
16 1.5 (DL-EQZ)
71.37534 30.24
0
17 0.9DL-1.5EQZ
53.77378
31.6
Joint

Mzz/Zzz
(3)
3.32
33.37
41.74
40.4
28.06
35.05
36.39
2.83
3.56
2.22
2.49
3.13
1.8

pmin =

13.46

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

89.893
121.197
141.203
120.891
94.134
107.321
89.699
115.551
134.147
113.836
92.05
104.746
87.174

83.073
115.217
133.723
116.151
89.194
101.141
86.239
56.271
60.027
42.456
43.65
44.266
23.974

76.433
48.477
50.243
35.351
33.074
31.041
13.459
50.611
52.907
38.016
38.67
38.006
20.374

83.253
54.457
57.723
40.091
38.014
37.221
16.919
109.89
127.03
109.4
87.07
98.486
83.574

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
245
F6-C31
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
23.60642 572.69
6 1.2 (DL+LL+EQX)
166.3701 572.69
7 1.5 (DL+EQX)
208.0771 572.69
8 0.9DL+1.5EQX
200.9557 572.69
9 1.2 (DL+LL-EQX)
139.8685 572.69
10 1.5 (DL-EQX)
174.7262 572.69
11 0.9DL-1.5EQX
180.8948 572.69
12 1.2 (DL+LL+EQZ)
147.841 572.69
13 1.5 (DL+EQZ)
184.8376 572.69
14 0.9DL+1.5EQZ
177.5654 572.69
15 1.2 (DL+LL-EQZ)
120.77
572.69
16 1.5 (DL-EQZ)
150.9476 572.69
17 0.9DL-1.5EQZ
157.168 572.69

666.06
691
853.14
590.96
374.71
457.78
195.6
664.84
820.44
558.26
400.87
490.48
228.3

52.48
7.6
6.86
5.8
6.78
5.9
4.25
8.38
7.54
6.37
8.07
7.05
5.1

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
19.64243
70.75635
88.61211
81.87634
46.53101
58.03103
63.3484
54.87332
68.7155
62.63324
35.66295
44.54568
47.7533

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3100
3100
425
0.210

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
799.2
815.28
919.89
750.74
611.23
664.82
495.67
798.4
898.79
729.64
628.1
685.92
516.77

20.35
5.77
5.2
4.59
6.57
5.73
3.92
7.28
6.54
5.83
8.81
7.7
5.42

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column =
550.41 kN
Punching Shear,P =
550.41 x (( 3.1 x 3.1 ) - ( 0.925 x 1.175 ))
( 3.1 * 3.1 )
P = 488.16 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

925
1175
4200

mm
mm
mm

Depth Required 488160


=
1.37 x4200
= 84.84 mm
Shear Resistance = 1.37 x 4200 x 425 / 1000
2445
kN
141.203

kN/m2

B) One Way Shear


750
0

1175

121.007

kN/m2

109.562

kN/m2

425

500

3100

750

500
200
1300
425

875

3100

133.723

kN/m2
138.067 kN/m2

141.203

kN/m2

139.092

kN/m2

57.723

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 139.092 - 25 x 0.5 - 18 x ( 2 99.592 kN/m2
-- For without
Length at critical section =
3100
mm
Width at critical section =
750
mm
Shear Force = 99.592 x 3.1 x 0.75
= 231.5514 kN
At Width
Maximum Pressure = 121.007 - 25 x 0.5 - 18 x ( 2 81.507 kN/m2
-- For without
Length at critical section =
3100
mm
Width at critical section =
875
mm
Shear Force = 81.507 x 3.1 x 0.875
= 221.0877 kN

0.5 )
Buoynacy Condition With Stress Increse

0.5 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 231.5514 kN


Corresponding Length =
3100
mm
% Ast =

0.210

Allowable Shear Stress =


0.338
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.338 x 1
2

N/mm
=
0.338
Depth Required = 231551.4
0.338 x 3100
=
296
mm
Check For Depth @ Critical Section
Critical section from face of
column =
425
mm
Min. Length from column face to
edge of footing =
1175
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
500
Depth @ Critical s/c =
391.49
Effe. Depth @ Critical s/c =
316.49
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 141.203
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 120.13 + 249.345 ) / ( 3.1 x 3.1 )
38.45
102.753 kN/m2
1.3

Bending Moment = 102.753 x 1.3 x 1.3 / 2


= 86.83 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

874.09
0.2
850
16
200.96
229
225

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

893.16

mm

Provide 16 mm dia Bars @ 225 mm spacing bothways

i.e.0.211%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 369.475 kN
Area Load = 369.475 / (3.1 x 3.1)
38.45
Maxi. Projection of fdn =

1.3

kN/m2
m

Bending Moment = 38.45 x 1.3 x 1.3 / 2


=
Ast =

32.49

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

321.12

Mini % of Re-bar =

0.12

Ast =
Use

510
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

221
220

mm
mm
2
Area Provided = 513.819 mm
Provide 12 mm dia Bars @ 220 mm spacing bothways

i.e.0.121%

Summary Of Design :Length Of Footing :3100 mm


WIdth Of Footing :3100 mm
Depth Of Footing :500
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 220 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 225 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
2.8
3.9
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.575

Wp

1.575
Z

1.15

Lp

F1

COLUMN NO.

C1

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.15

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 2.8 x 3.9 x 0.6
=
163.8
kN
Buoyant Self wt. of Fdn = 0 x 2.8 x 3.9 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(2.8 x 3.9) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
265.734 kN
Buoyant weight of Soil = [(2.8 x 3.9) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 163.8 + 0 + 265.734


=
429.53 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
248
F1-C1

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
4.757
469.998
6 1.2 (DL+LL+EQX)
-68.992
99.953
7 1.5 (DL+EQX)
-86.502
120.39
8 0.9DL+1.5EQX
-88.3
-65.789
9 1.2 (DL+LL-EQX)
76.603
652.044
10 1.5 (DL-EQX)
95.492
810.504
11 0.9DL-1.5EQX
93.694
624.325
12 1.2 (DL+LL+EQZ)
3.441
303.123
13 1.5 (DL+EQZ)
4.039
374.353
14 0.9DL+1.5EQZ
2.241
188.174
15 1.2 (DL+LL-EQZ)
4.17
448.874
16 1.5 (DL-EQZ)
4.95
556.541
17 0.9DL-1.5EQZ
3.152
370.362

kN - m)
FORCE-Z
41.548
33.322
41.888
25.175
33.155
41.679
24.966
-20.909
-25.901
-42.615
87.386
109.468
92.755

MOM-X
36.559
28.717
35.763
21.193
29.777
37.087
22.517
-151.557
-189.58
-204.15
210.051
262.43
247.86

MOM-Y
-7.946
-20.18
-24.31
-21.5
7.463
10.239
13.053
14.112
18.55
21.364
-26.83
-32.62
-29.81

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 2.8 x 3.9
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

10.92

m2

1/6 x 2.8 x 3.9 x 3.9


7.098

m3

1/6 x 3.9 x 2.8 x 2.8


5.096

m3

Total Vertical Load P = 469.998 + 429.53


= 899.528 kN

MOM Z
-6.588
164.198
205.637
208.117
-174.739
-218.035
-215.555
-4.026
-4.643
-2.163
-6.515
-7.755
-5.275

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 899.528 / (2.8 x 3.9 )


=

82.374

kN/m

Mxx/Zxx = 36.559 / 7.098


Mxx/Zxx =

5.151

kN/m

Mzz/Zzz = 6.588 / 5.096


Mzz/Zzz =

1.293

kN/m

Maxi.Soil Pressure pmax = 82.374 + 5.151 + 1.293


pmax =

88.82

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 82.374 - 5.151 - 1.293
pmin =

75.93

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
37.15
kN.m
Calculation of Stabilizing Moment
Due to External Load = 469.998 x 2.8 / 2
=
658 kN.m
Due to wt. of Pedestral = 0 x 1.4
=
0

kN.m

Due to Self Wt. of Fdn = 163.8 x 1.4


=
229.32 kN.m
Due to Wt. of Soil = 265.734 x 1.4
=
372.03 kN.m
Total Stabilizing moment = 658 + 0 + 229.32 + 372.03
=
1259.35 kN.m
F.O.S. against Overturning = 1259.35 / 37.15
= 33.8991 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

41.82

kN

Total Vertical Load = 899.528 kN


F.O.S. against Sliding = 899.528 x 0.5 / 41.82
= 10.76
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
248 5 1.5 (DL+LL)
469.998 43.04011
F1-C1 6 1.2 (DL+LL+EQX)
99.953 9.153205
0
7 1.5 (DL+EQX)
120.39 11.02473
0
8 0.9DL+1.5EQX
-65.789 -6.02463
0
9 1.2 (DL+LL-EQX)
652.044 59.71099
0
10 1.5 (DL-EQX)
810.504 74.22198
0
11 0.9DL-1.5EQX
624.325 57.17262
0
12 1.2 (DL+LL+EQZ)
303.123 27.75852
0
13 1.5 (DL+EQZ)
374.353 34.28141
0
14 0.9DL+1.5EQZ
188.174 17.23205
0
15 1.2 (DL+LL-EQZ)
448.874 41.10568
0
16 1.5 (DL-EQZ)
556.541 50.96529
0
17 0.9DL-1.5EQZ
370.362 33.91593
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

5.16
4.05
5.04
2.99
4.2
5.23
3.18
21.36
26.71
28.77
29.6
36.98
34.92

1.3
32.23
40.36
40.84
34.29
42.79
42.3
0.8
0.92
0.43
1.28
1.53
1.04

49.5001
45.4332
56.4247
37.8054
98.201
122.242
102.653
49.9185
61.9114
46.4321
71.9857
89.4753
69.8759

140
166
166
166
166
166
166
166
166
166
166
166
166

36.59
-27.13
-34.38
-49.86
21.23
26.21
11.7
5.6
6.66
-11.97
10.23
12.46
-2.05

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 49.50011 kN/m2
pmax = 122.242 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
248 5 1.5 (DL+LL)
43.04011
5.16
F1-C1 6 1.2 (DL+LL+EQX)
9.153205
4.05
0
7 1.5 (DL+EQX)
11.02473
5.04
0
8 0.9DL+1.5EQX
-6.02463
2.99
0
9 1.2 (DL+LL-EQX)
59.71099
4.2
0
10 1.5 (DL-EQX)
74.22198
5.23
0
11 0.9DL-1.5EQX
57.17262
3.18
0
12 1.2 (DL+LL+EQZ)
27.75852 21.36
0
13 1.5 (DL+EQZ)
34.28141 26.71
0
14 0.9DL+1.5EQZ
17.23205 28.77
0
15 1.2 (DL+LL-EQZ)
41.10568
29.6
0
16 1.5 (DL-EQZ)
50.96529 36.98
0
17 0.9DL-1.5EQZ
33.91593 34.92
Joint

kN/m2

Mzz/Zzz
(3)
1.3
32.23
40.36
40.84
34.29
42.79
42.3
0.8
0.92
0.43
1.28
1.53
1.04

pmin =

1+2+3

1-2+3

-49.86 kN/m2

1-2-3

1+2-3

49.501 39.181
36.581 46.901
45.434 37.334 -27.127 -19.03
56.425 46.345 -34.376 -24.3
37.806 31.826 -49.855 -43.88
98.201 89.801
21.221 29.621
122.242 111.782 26.202 36.662
102.653 96.293
11.693 18.053
49.919
7.199
5.599
48.319
61.912
8.492
6.652
60.072
46.433 -11.108 -11.968 45.573
71.986 12.786
10.226 69.426
89.476 15.516
12.456 86.416
69.876
0.036
-2.045 67.796

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
248 5 1.5 (DL+LL)
899.528 82.37436
F1-C1 6 1.2 (DL+LL+EQX)
529.483 48.48745
0
7 1.5 (DL+EQX)
549.92 50.35897
0
8 0.9DL+1.5EQX
363.741 33.30962
0
9 1.2 (DL+LL-EQX)
1081.574 99.04524
0
10 1.5 (DL-EQX)
1240.034 113.5562
0
11 0.9DL-1.5EQX
1053.855 96.50687
0
12 1.2 (DL+LL+EQZ)
732.653 67.09277
0
13 1.5 (DL+EQZ)
803.883 73.61566
0
14 0.9DL+1.5EQZ
617.704 56.5663
0
15 1.2 (DL+LL-EQZ)
878.404 80.43993
0
16 1.5 (DL-EQZ)
986.071 90.29954
0
17 0.9DL-1.5EQZ
799.892 73.25018
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

5.16
4.05
5.04
2.99
4.2
5.23
3.18
21.36
26.71
28.77
29.6
36.98
34.92

1.3
32.23
40.36
40.84
34.29
42.79
42.3
0.8
0.92
0.43
1.28
1.53
1.04

88.8344
84.7675
95.759
77.1396
137.535
161.576
141.987
89.2528
101.246
85.7663
111.32
128.81
109.21

140
166
166
166
166
166
166
166
166
166
166
166
166

75.92
12.21
4.96
-10.53
60.56
65.54
51.03
44.94
45.99
27.37
49.56
51.79
37.3

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 88.83436 kN/m2
pmax = 161.5762 kN/m2
pmin =

75.92 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
248 5 1.5 (DL+LL)
82.37436
5.16
F1-C1 6 1.2 (DL+LL+EQX)
48.48745
4.05
0
7 1.5 (DL+EQX)
50.35897
5.04
0
8 0.9DL+1.5EQX
33.30962
2.99
0
9 1.2 (DL+LL-EQX)
99.04524
4.2
0
10 1.5 (DL-EQX)
113.5562
5.23
0
11 0.9DL-1.5EQX
96.50687
3.18
0
12 1.2 (DL+LL+EQZ)
67.09277 21.36
0
13 1.5 (DL+EQZ)
73.61566 26.71
0
14 0.9DL+1.5EQZ
56.5663 28.77
0
15 1.2 (DL+LL-EQZ)
80.43993
29.6
0
16 1.5 (DL-EQZ)
90.29954 36.98
0
17 0.9DL-1.5EQZ
73.25018 34.92
Joint

Mzz/Zzz
(3)
1.3
32.23
40.36
40.84
34.29
42.79
42.3
0.8
0.92
0.43
1.28
1.53
1.04

pmin =

1+2+3

1-2+3

-10.53 kN/m2

1-2-3

1+2-3

88.835 78.515
75.915 86.235
84.768 76.668
12.208 20.308
95.759 85.679
4.959
15.039
77.14
71.16
-10.521 -4.541
137.536 129.136 60.556 68.956
161.577 151.117 65.537 75.997
141.987 135.627 51.027 57.387
89.253 46.533
44.933 87.653
101.246 47.826
45.986 99.406
85.767 28.227
27.367 84.907
111.32
52.12
49.56
108.76
128.81
54.85
51.79
125.75
109.211 39.371
37.291 107.13

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
248
F1-C1
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
37.14784 601.35
6 1.2 (DL+LL+EQX)
166.6903 601.35
7 1.5 (DL+EQX)
208.7237 601.35
8 0.9DL+1.5EQX
209.1933 601.35
9 1.2 (DL+LL-EQX)
177.258 601.35
10 1.5 (DL-EQX)
221.1667 601.35
11 0.9DL-1.5EQX
216.7279 601.35
12 1.2 (DL+LL+EQZ)
151.6105 601.35
13 1.5 (DL+EQZ)
189.6368 601.35
14 0.9DL+1.5EQZ
204.1615 601.35
15 1.2 (DL+LL-EQZ)
210.152 601.35
16 1.5 (DL-EQZ)
262.5446 601.35
17 0.9DL-1.5EQZ
247.9161 601.35

658
139.94
168.55
-92.11
912.87
1134.71
874.06
424.38
524.1
263.45
628.43
779.16
518.51

33.91
4.45
3.69
2.44
8.55
7.85
6.81
6.77
5.94
4.24
5.86
5.26
4.52

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
41.81944
76.61757
96.11036
91.81868
83.4702
104.1915
96.96322
21.19025
26.21403
42.67388
87.48544
109.5799
92.80854

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

2800
3900
525
0.225

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
899.53
529.48
549.92
363.74
1081.6
1240
1053.9
732.65
803.88
617.7
878.4
986.07
799.89

10.76
3.46
2.87
1.99
6.48
5.96
5.44
17.29
15.34
7.24
5.03
4.5
4.31

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 810.504 kN
Punching Shear,P =
810.504 x (( 2.8 x 3.9 ) - ( 1.025 x 1.275 ))
( 2.8 * 3.9 )
P = 713.51 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 713510


=
1.37 x4600
= 113.22 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
161.577

kN/m2

B) One Way Shear


1050
0

1575

138.537

kN/m2

127.016

kN/m2

525

600

3900

750

500
200
1150
525

625

2800

151.117

kN/m2
157.281 kN/m2

161.577

kN/m2

159.243

kN/m2

75.997

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 159.243 - 25 x 0.6 - 18 x ( 2 119.043 kN/m2
-- For without
Length at critical section =
2800
mm
Width at critical section =
1050
mm
Shear Force = 119.043 x 2.8 x 1.05
= 349.9864 kN
At Width
Maximum Pressure = 138.537 - 25 x 0.6 - 18 x ( 2 98.337 kN/m2
-- For without
Length at critical section =
3900
mm
Width at critical section =
625
mm
Shear Force = 98.337 x 3.9 x 0.625
= 239.6964 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 349.98642 kN


Corresponding Length =
2800
mm
% Ast =

0.225

Allowable Shear Stress =


0.346
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.346 x 1
2

N/mm
=
0.346
Depth Required = 349986.42
0.346 x 2800
=
437
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1150
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
417.4
Effe. Depth @ Critical s/c =
342.4
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 161.577
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Revise

Bottom
-- Without Buoyancy Load Case
( 163.8 + 265.734 ) / ( 2.8 x 3.9 )
39.33
122.247 kN/m2
1.575

Bending Moment = 122.247 x 1.575 x 1.575 / 2


= 151.62 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

1241.01
0.2
1050
16
200.96
161
170

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1182.12

mm

Provide 16 mm dia Bars @ 170 mm spacing bothways

i.e.0.226%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 429.534 kN
Area Load = 429.534 / (2.8 x 3.9)

Maxi. Projection of fdn =

39.33

kN/m2

1.575

Bending Moment = 39.33 x 1.575 x 1.575 / 2


=
Ast =

48.78

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

390.22

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :2800 mm


WIdth Of Footing :3900 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 170 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
2.75
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.125

Lp

F2

COLUMN NO.

C2

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.125

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 2.75 x 4.6 x 0.6
=
189.75 kN
Buoyant Self wt. of Fdn = 0 x 2.75 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(2.75 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
309.33 kN
Buoyant weight of Soil = [(2.75 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 189.75 + 0 + 309.33


=
499.08 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
249
F2-C2

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
9.977
737.599
6 1.2 (DL+LL+EQX)
-87.342 765.996
7 1.5 (DL+EQX)
-109.261 935.274
8 0.9DL+1.5EQX
-113.219 649.123
9 1.2 (DL+LL-EQX)
103.306 414.162
10 1.5 (DL-EQX)
129.049
495.48
11 0.9DL-1.5EQX
125.091 209.329
12 1.2 (DL+LL+EQZ)
7.454
566.77
13 1.5 (DL+EQZ)
9.234
686.241
14 0.9DL+1.5EQZ
5.276
400.09
15 1.2 (DL+LL-EQZ)
8.51
613.388
16 1.5 (DL-EQZ)
10.554
744.513
17 0.9DL-1.5EQZ
6.596
458.362

kN - m)
FORCE-Z
23.992
23.043
26.183
17.635
15.344
16.559
8.011
-28.412
-38.136
-46.685
66.799
80.878
72.33

MOM-X
76.942
69.851
77.8
50.829
53.256
57.056
30.085
-198.472
-257.604
-284.575
321.579
392.459
365.488

MOM-Y
0.98
-1.658
-2.034
-2.442
3.227
4.072
3.664
22.663
28.367
27.96
-21.1
-26.33
-26.74

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 2.75 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

12.65

m2

1/6 x 2.75 x 4.6 x 4.6


9.699

m3

1/6 x 4.6 x 2.75 x 2.75


5.798

m3

Total Vertical Load P = 737.599 + 499.08


= 1236.679 kN

MOM Z
-12.5
185.044
231.494
236.418
-205.044
-256.116
-251.192
-8.642
-10.614
-5.689
-11.358
-14.009
-9.084

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1236.679 / (2.75 x 4.6 )


=

97.761

kN/m

Mxx/Zxx = 76.942 / 9.699


Mxx/Zxx =

7.933

kN/m

Mzz/Zzz = 12.5 / 5.798


Mzz/Zzz =

2.156

kN/m

Maxi.Soil Pressure pmax = 97.761 + 7.933 + 2.156


pmax =

107.85

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 97.761 - 7.933 - 2.156
pmin =

87.68

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
77.96
kN.m
Calculation of Stabilizing Moment
Due to External Load = 737.599 x 2.75 / 2
=
1014.2 kN.m
Due to wt. of Pedestral = 0 x 1.375
=
0
kN.m
Due to Self Wt. of Fdn = 189.75 x 1.375
=
260.91 kN.m
Due to Wt. of Soil = 309.33 x 1.375
=
425.33 kN.m
Total Stabilizing moment = 1014.2 + 0 + 260.91 + 425.33
=
1700.44 kN.m
F.O.S. against Overturning = 1700.44 / 77.96
= 21.8117 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

25.99

kN

Total Vertical Load = 1236.68 kN


F.O.S. against Sliding = 1236.679 x 0.5 / 25.99
=
23.8
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
249 5 1.5 (DL+LL)
737.599 58.30822
F2-C2 6 1.2 (DL+LL+EQX)
765.996 60.55304
0
7 1.5 (DL+EQX)
935.274 73.9347
0
8 0.9DL+1.5EQX
649.123 51.31407
0
9 1.2 (DL+LL-EQX)
414.162 32.74008
0
10 1.5 (DL-EQX)
495.48 39.16838
0
11 0.9DL-1.5EQX
209.329 16.54775
0
12 1.2 (DL+LL+EQZ)
566.77 44.80395
0
13 1.5 (DL+EQZ)
686.241 54.2483
0
14 0.9DL+1.5EQZ
400.09 31.62767
0
15 1.2 (DL+LL-EQZ)
613.388 48.48917
0
16 1.5 (DL-EQZ)
744.513 58.85478
0
17 0.9DL-1.5EQZ
458.362 36.23415
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

7.94
7.21
8.03
5.25
5.5
5.89
3.11
20.47
26.56
29.35
33.16
40.47
37.69

2.16
31.92
39.93
40.78
35.37
44.18
43.33
1.5
1.84
0.99
1.96
2.42
1.57

68.4082
99.683
121.895
97.3441
73.6101
89.2384
62.9877
66.774
82.6483
61.9677
83.6092
101.745
75.4942

140
166
166
166
166
166
166
166
166
166
166
166
166

48.21
21.43
25.98
5.29
-8.13
-10.91
-29.9
22.84
25.85
1.29
13.37
15.97
-3.03

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 68.40822 kN/m2
pmax = 121.8947 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
249 5 1.5 (DL+LL)
58.30822
7.94
F2-C2 6 1.2 (DL+LL+EQX)
60.55304
7.21
0
7 1.5 (DL+EQX)
73.9347
8.03
0
8 0.9DL+1.5EQX
51.31407
5.25
0
9 1.2 (DL+LL-EQX)
32.74008
5.5
0
10 1.5 (DL-EQX)
39.16838
5.89
0
11 0.9DL-1.5EQX
16.54775
3.11
0
12 1.2 (DL+LL+EQZ)
44.80395 20.47
0
13 1.5 (DL+EQZ)
54.2483 26.56
0
14 0.9DL+1.5EQZ
31.62767 29.35
0
15 1.2 (DL+LL-EQZ)
48.48917 33.16
0
16 1.5 (DL-EQZ)
58.85478 40.47
0
17 0.9DL-1.5EQZ
36.23415 37.69
Joint

kN/m2

Mzz/Zzz
(3)
2.16
31.92
39.93
40.78
35.37
44.18
43.33
1.5
1.84
0.99
1.96
2.42
1.57

pmin =

1+2+3

1-2+3

-29.9

1-2-3

kN/m2

1+2-3

68.409 52.529
48.209 64.089
99.684 85.264
21.424 35.844
121.895 105.835 25.975 42.035
97.345 86.845
5.285
15.785
73.611 62.611
-8.13
2.871
89.239 77.459 -10.902 0.879
62.988 56.768 -29.893 -23.67
66.774 25.834
22.834 63.774
82.649 29.529
25.849 78.969
61.968
3.268
1.288
59.988
83.61
17.29
13.37
79.69
101.745 20.805
15.965 96.905
75.495
0.115
-3.026 72.355

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
249 5 1.5 (DL+LL)
1236.679 97.76119
F2-C2 6 1.2 (DL+LL+EQX)
1265.076 100.006
0
7 1.5 (DL+EQX)
1434.354 113.3877
0
8 0.9DL+1.5EQX
1148.203 90.76704
0
9 1.2 (DL+LL-EQX)
913.242 72.19304
0
10 1.5 (DL-EQX)
994.56 78.62134
0
11 0.9DL-1.5EQX
708.409 56.00071
0
12 1.2 (DL+LL+EQZ)
1065.85 84.25692
0
13 1.5 (DL+EQZ)
1185.321 93.70126
0
14 0.9DL+1.5EQZ
899.17 71.08063
0
15 1.2 (DL+LL-EQZ)
1112.468 87.94213
0
16 1.5 (DL-EQZ)
1243.593 98.30775
0
17 0.9DL-1.5EQZ
957.442 75.68711
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

7.94
7.21
8.03
5.25
5.5
5.89
3.11
20.47
26.56
29.35
33.16
40.47
37.69

2.16
31.92
39.93
40.78
35.37
44.18
43.33
1.5
1.84
0.99
1.96
2.42
1.57

107.861
139.136
161.348
136.797
113.063
128.691
102.441
106.227
122.101
101.421
123.062
141.198
114.947

140
166
166
166
166
166
166
166
166
166
166
166
166

87.67
60.88
65.43
44.74
31.33
28.56
9.57
62.29
65.31
40.75
52.83
55.42
36.43

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 107.8612 kN/m2
pmax = 161.3477 kN/m2
pmin =

87.67 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
249 5 1.5 (DL+LL)
97.76119
7.94
F2-C2 6 1.2 (DL+LL+EQX)
100.006
7.21
0
7 1.5 (DL+EQX)
113.3877
8.03
0
8 0.9DL+1.5EQX
90.76704
5.25
0
9 1.2 (DL+LL-EQX)
72.19304
5.5
0
10 1.5 (DL-EQX)
78.62134
5.89
0
11 0.9DL-1.5EQX
56.00071
3.11
0
12 1.2 (DL+LL+EQZ)
84.25692 20.47
0
13 1.5 (DL+EQZ)
93.70126 26.56
0
14 0.9DL+1.5EQZ
71.08063 29.35
0
15 1.2 (DL+LL-EQZ)
87.94213 33.16
0
16 1.5 (DL-EQZ)
98.30775 40.47
0
17 0.9DL-1.5EQZ
75.68711 37.69
Joint

Mzz/Zzz
(3)
2.16
31.92
39.93
40.78
35.37
44.18
43.33
1.5
1.84
0.99
1.96
2.42
1.57

pmin =

9.57

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

107.862
139.137
161.348
136.798
113.064
128.692
102.441
106.227
122.102
101.421
123.063
141.198
114.948

91.982
124.717
145.288
126.298
102.064
116.912
96.221
65.287
68.982
42.721
56.743
60.258
39.568

87.662
60.877
65.428
44.738
31.324
28.552
9.561
62.287
65.302
40.741
52.823
55.418
36.428

103.54
75.297
81.488
55.238
42.324
40.332
15.781
103.23
118.42
99.441
119.14
136.36
111.81

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
249
F2-C2
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
77.95076 686.24
6 1.2 (DL+LL+EQX)
197.7889 686.24
7 1.5 (DL+EQX)
244.2178 686.24
8 0.9DL+1.5EQX
241.8203 686.24
9 1.2 (DL+LL-EQX)
211.8472 686.24
10 1.5 (DL-EQX)
262.3943 686.24
11 0.9DL-1.5EQX
252.9872 686.24
12 1.2 (DL+LL+EQZ)
198.6601 686.24
13 1.5 (DL+EQZ)
257.8226 686.24
14 0.9DL+1.5EQZ
284.6319 686.24
15 1.2 (DL+LL-EQZ)
321.7795 686.24
16 1.5 (DL-EQZ)
392.7089 686.24
17 0.9DL-1.5EQZ
365.6009 686.24

1014.2
1053.25
1286.01
892.55
569.48
681.29
287.83
779.31
943.59
550.13
843.41
1023.71
630.25

21.82
8.8
8.08
6.53
5.93
5.22
3.86
7.38
6.33
4.35
4.76
4.36
3.61

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
25.98378
90.33053
112.3544
114.5842
104.4393
130.1071
125.3473
29.37352
39.23801
46.98218
67.33889
81.5637
72.63013

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

2750
4600
525
0.374

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1236.7
1265.1
1434.4
1148.2
913.24
994.56
708.41
1065.9
1185.3
899.17
1112.5
1243.6
957.44

23.8
7.01
6.39
5.02
4.38
3.83
2.83
18.15
15.11
9.57
8.27
7.63
6.6

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 935.274 kN
Punching Shear,P =
935.274 x (( 2.75 x 4.6 ) - ( 1.025 x 1.275 ))
( 2.75 * 4.6 )
P = 838.66 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 838660


=
1.37 x4600
= 133.08 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
161.348

kN/m2

B) One Way Shear


1400
0

1925

137.043

kN/m2

127.929

kN/m2

525

600

4600

750

500
200
1125
525

600

2750

145.288

kN/m2
154.778 kN/m2

161.348

kN/m2

157.844

kN/m2

81.488

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 157.844 - 25 x 0.6 - 18 x ( 2 117.644 kN/m2
-- For without
Length at critical section =
2750
mm
Width at critical section =
1400
mm
Shear Force = 117.644 x 2.75 x 1.4
= 452.9294 kN
At Width
Maximum Pressure = 137.043 - 25 x 0.6 - 18 x ( 2 96.843 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
600
mm
Shear Force = 96.843 x 4.6 x 0.6
= 267.2867 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 452.9294 kN


Corresponding Length =
2750
mm
% Ast =

0.374

Allowable Shear Stress =


0.4324 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4324 x 1
2
=
0.4324 N/mm
Depth Required = 452929.4
0.4324 x 2750
=
456
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm

Min. Length from column face to


edge of footing =
1125
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
413.34
Effe. Depth @ Critical s/c =
338.34
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 161.348
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Revise

Bottom
-- Without Buoyancy Load Case
( 189.75 + 309.33 ) / ( 2.75 x 4.6 )
39.45
121.898 kN/m2
1.925

Bending Moment = 121.898 x 1.925 x 1.925 / 2


= 225.85 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1881.41
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
166
160

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1962.5

mm

Provide 20 mm dia Bars @ 160 mm spacing bothways

i.e.0.374%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
499.08 kN
Area Load = 499.08 / (2.75 x 4.6)

Maxi. Projection of fdn =

39.45

kN/m2

1.925

Bending Moment = 39.45 x 1.925 x 1.925 / 2


=
Ast =

73.09

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

587.79

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :2750 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 160 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C3

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
261
F3-C3

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-2.485
1101.32
6 1.2 (DL+LL+EQX)
-89.198
856.23
7 1.5 (DL+EQX)
-111.663 1037.71
8 0.9DL+1.5EQX
-110.603 610.215
9 1.2 (DL+LL-EQX)
85.222
905.879
10 1.5 (DL-EQX)
106.361 1099.77
11 0.9DL-1.5EQX
107.422 672.277
12 1.2 (DL+LL+EQZ)
-2.528
820.608
13 1.5 (DL+EQZ)
-3.326
993.185
14 0.9DL+1.5EQZ
-2.265
565.688
15 1.2 (DL+LL-EQZ)
-1.448
941.501
16 1.5 (DL-EQZ)
-1.976
1144.3
17 0.9DL-1.5EQZ
-0.916
716.804

kN - m)
FORCE-Z
22.874
17.567
26.073
15.278
19.031
27.904
17.108
-68.933
-82.052
-92.848
105.532
136.029
125.234

MOM-X
2.52
0.227
2.982
0.895
3.805
7.455
5.367
-367.795
-457.045
-459.133
371.827
467.482
465.394

MOM-Y
-5.629
-15.71
-18.94
-16.96
6.699
9.069
11.042
6.019
8.219
10.192
-15.03
-18.09
-16.11

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 1101.318 + 600.79


= 1702.108 kN

MOM Z
1.741
187.366
234.472
233.67
-184.581
-230.462
-231.264
2.627
3.548
2.746
0.158
0.462
-0.34

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1702.108 / (3.3 x 4.6 )


=

112.128

kN/m

Mxx/Zxx = 2.52 / 11.638


Mxx/Zxx =

0.217

kN/m

Mzz/Zzz = 1.741 / 8.349


Mzz/Zzz =

0.209

kN/m

Maxi.Soil Pressure pmax = 112.128 + 0.217 + 0.209


pmax =

112.56

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 112.128 - 0.217 - 0.209
pmin =

111.71

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
3.07
kN.m
Calculation of Stabilizing Moment
Due to External Load = 1101.318 x 3.3 / 2
=
1817.18 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1817.18 + 0 + 375.71 + 615.6
=
2808.49 kN.m
F.O.S. against Overturning = 2808.49 / 3.07
= 914.818 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

23.01

kN

Total Vertical Load = 1702.11 kN


F.O.S. against Sliding = 1702.108 x 0.5 / 23.01
= 36.99
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
261 5 1.5 (DL+LL)
1101.318 72.55059
F3-C3 6 1.2 (DL+LL+EQX)
856.23 56.40514
0
7 1.5 (DL+EQX)
1037.712 68.36047
0
8 0.9DL+1.5EQX
610.215 40.19862
0
9 1.2 (DL+LL-EQX)
905.879 59.67582
0
10 1.5 (DL-EQX)
1099.774 72.44888
0
11 0.9DL-1.5EQX
672.277 44.28702
0
12 1.2 (DL+LL+EQZ)
820.608 54.0585
0
13 1.5 (DL+EQZ)
993.185 65.42721
0
14 0.9DL+1.5EQZ
565.688 37.26535
0
15 1.2 (DL+LL-EQZ)
941.501 62.02246
0
16 1.5 (DL-EQZ)
1144.301 75.38215
0
17 0.9DL-1.5EQZ
716.804 47.22029
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

0.22
0.02
0.26
0.08
0.33
0.65
0.47
31.61
39.28
39.46
31.95
40.17
39.99

0.21
22.45
28.09
27.99
22.11
27.61
27.7
0.32
0.43
0.33
0.02
0.06
0.05

72.9806
78.8751
96.7105
68.2686
82.1158
100.709
72.457
85.9885
105.137
77.0553
93.9925
115.612
87.2603

140
166
166
166
166
166
166
166
166
166
166
166
166

72.13
33.94
40.02
12.13
37.24
44.19
16.12
22.13
25.72
-2.53
30.06
35.16
7.19

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 72.98059 kN/m2
pmax = 115.6121 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
261 5 1.5 (DL+LL)
72.55059
0.22
F3-C3 6 1.2 (DL+LL+EQX)
56.40514
0.02
0
7 1.5 (DL+EQX)
68.36047
0.26
0
8 0.9DL+1.5EQX
40.19862
0.08
0
9 1.2 (DL+LL-EQX)
59.67582
0.33
0
10 1.5 (DL-EQX)
72.44888
0.65
0
11 0.9DL-1.5EQX
44.28702
0.47
0
12 1.2 (DL+LL+EQZ)
54.0585 31.61
0
13 1.5 (DL+EQZ)
65.42721 39.28
0
14 0.9DL+1.5EQZ
37.26535 39.46
0
15 1.2 (DL+LL-EQZ)
62.02246 31.95
0
16 1.5 (DL-EQZ)
75.38215 40.17
0
17 0.9DL-1.5EQZ
47.22029 39.99
Joint

kN/m2

Mzz/Zzz
(3)
0.21
22.45
28.09
27.99
22.11
27.61
27.7
0.32
0.43
0.33
0.02
0.06
0.05

pmin =

-2.53

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

72.981
78.876
96.711
68.269
82.116
100.709
72.458
85.989
105.138
77.056
93.993
115.613
87.261

72.541
78.836
96.191
68.109
81.456
99.409
71.518
22.769
26.578
-1.865
30.093
35.273
7.281

72.121
33.936
40.011
12.129
37.236
44.189
16.118
22.129
25.718
-2.525
30.053
35.153
7.181

72.561
33.976
40.531
12.289
37.896
45.489
17.058
85.349
104.28
76.396
93.953
115.49
87.161

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
261 5 1.5 (DL+LL)
1702.108 112.1283
F3-C3 6 1.2 (DL+LL+EQX)
1457.02 95.98287
0
7 1.5 (DL+EQX)
1638.502 107.9382
0
8 0.9DL+1.5EQX
1211.005 79.77635
0
9 1.2 (DL+LL-EQX)
1506.669 99.25356
0
10 1.5 (DL-EQX)
1700.564 112.0266
0
11 0.9DL-1.5EQX
1273.067 83.86476
0
12 1.2 (DL+LL+EQZ)
1421.398 93.63623
0
13 1.5 (DL+EQZ)
1593.975 105.0049
0
14 0.9DL+1.5EQZ
1166.478 76.84308
0
15 1.2 (DL+LL-EQZ)
1542.291 101.6002
0
16 1.5 (DL-EQZ)
1745.091 114.9599
0
17 0.9DL-1.5EQZ
1317.594 86.79802
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

0.22
0.02
0.26
0.08
0.33
0.65
0.47
31.61
39.28
39.46
31.95
40.17
39.99

0.21
22.45
28.09
27.99
22.11
27.61
27.7
0.32
0.43
0.33
0.02
0.06
0.05

112.558
118.453
136.288
107.846
121.694
140.287
112.035
125.566
144.715
116.633
133.57
155.19
126.838

140
166
166
166
166
166
166
166
166
166
166
166
166

111.7
73.52
79.59
51.71
76.82
83.77
55.7
61.71
65.3
37.06
69.64
74.73
46.76

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 112.5583 kN/m2
pmax = 155.1899 kN/m2
pmin =

111.7 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
261 5 1.5 (DL+LL)
112.1283
0.22
F3-C3 6 1.2 (DL+LL+EQX)
95.98287
0.02
0
7 1.5 (DL+EQX)
107.9382
0.26
0
8 0.9DL+1.5EQX
79.77635
0.08
0
9 1.2 (DL+LL-EQX)
99.25356
0.33
0
10 1.5 (DL-EQX)
112.0266
0.65
0
11 0.9DL-1.5EQX
83.86476
0.47
0
12 1.2 (DL+LL+EQZ)
93.63623 31.61
0
13 1.5 (DL+EQZ)
105.0049 39.28
0
14 0.9DL+1.5EQZ
76.84308 39.46
0
15 1.2 (DL+LL-EQZ)
101.6002 31.95
0
16 1.5 (DL-EQZ)
114.9599 40.17
0
17 0.9DL-1.5EQZ
86.79802 39.99
Joint

Mzz/Zzz
(3)
0.21
22.45
28.09
27.99
22.11
27.61
27.7
0.32
0.43
0.33
0.02
0.06
0.05

pmin =

1+2+3
112.559
118.453
136.289
107.847
121.694
140.287
112.035
125.567
144.715
116.634
133.571
155.19
126.839

1-2+3

37.06

1-2-3

kN/m2

1+2-3

112.119 111.699 112.14


118.413 73.513 73.553
135.769 79.589 80.109
107.687 51.707 51.867
121.034 76.814 77.474
138.987 83.767 85.067
111.095 55.695 56.635
62.347
61.707 124.93
66.155
65.295 143.86
37.714
37.054 115.97
69.671
69.631 133.53
74.85
74.73
155.07
46.859
46.759 126.74

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
261
F3-C3
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
3.06292 991.31
6 1.2 (DL+LL+EQX)
187.3661 991.31
7 1.5 (DL+EQX)
234.491 991.31
8 0.9DL+1.5EQX
233.6717 991.31
9 1.2 (DL+LL-EQX)
184.6202 991.31
10 1.5 (DL-EQX)
230.5825 991.31
11 0.9DL-1.5EQX
231.3263 991.31
12 1.2 (DL+LL+EQZ)
367.8044 991.31
13 1.5 (DL+EQZ)
457.0588 991.31
14 0.9DL+1.5EQZ
459.1412 991.31
15 1.2 (DL+LL-EQZ)
371.827 991.31
16 1.5 (DL-EQZ)
467.4822 991.31
17 0.9DL-1.5EQZ
465.3941 991.31

1817.18
1412.78
1712.23
1006.86
1494.71
1814.63
1109.26
1354.01
1638.76
933.39
1553.48
1888.1
1182.73

916.94
12.84
11.53
8.56
13.47
12.17
9.09
6.38
5.76
4.2
6.85
6.16
4.68

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
23.00859
90.9114
114.6666
111.6532
87.32106
109.9604
108.7758
68.97934
82.11938
92.87562
105.5419
136.0434
125.2373

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.342

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1702.1
1457
1638.5
1211
1506.7
1700.6
1273.1
1421.4
1594
1166.5
1542.3
1745.1
1317.6

36.99
8.02
7.15
5.43
8.63
7.74
5.86
10.31
9.71
6.28
7.31
6.42
5.27

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 1144.301 kN
Punching Shear,P =
1144.301 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 1045.79 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 1045790


=
1.37 x4600
= 165.95 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
155.19

kN/m2

B) One Way Shear


1400
0

1925

155.154

kN/m2

155.14

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

74.85

kN/m2
121.107 kN/m2

155.19

kN/m2

133.888

kN/m2

155.07

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 133.888 - 25 x 0.6 - 18 x ( 2 93.688 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 93.688 x 3.3 x 1.4
= 432.8386 kN
At Width
Maximum Pressure = 155.154 - 25 x 0.6 - 18 x ( 2 114.954 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 114.954 x 4.6 x 0.875
= 462.6899 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 462.68985 kN


Corresponding Length =
4600
mm
% Ast =

0.342

Allowable Shear Stress =


0.4168 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4168 x 1
2

=
0.4168 N/mm
Depth Required = 462689.85
0.4168 x 4600
=
317
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure =
155.19
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
115.61 kN/m2
1.925

Bending Moment = 115.61 x 1.925 x 1.925 / 2


= 214.2 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1779.33
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
176
175

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1794.29

mm

Provide 20 mm dia Bars @ 175 mm spacing bothways

i.e.0.342%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 175 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C4

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
250
F3-C4

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
1.057
779.083
6 1.2 (DL+LL+EQX)
-88.421 629.083
7 1.5 (DL+EQX)
-110.587 757.016
8 0.9DL+1.5EQX
-110.986 457.118
9 1.2 (DL+LL-EQX)
90.113
617.449
10 1.5 (DL-EQX)
112.581 742.474
11 0.9DL-1.5EQX
112.182 442.576
12 1.2 (DL+LL+EQZ)
0.458
587.344
13 1.5 (DL+EQZ)
0.512
704.843
14 0.9DL+1.5EQZ
0.113
404.945
15 1.2 (DL+LL-EQZ)
1.234
659.188
16 1.5 (DL-EQZ)
1.482
794.648
17 0.9DL-1.5EQZ
1.083
494.75

kN - m)
FORCE-Z
72.685
59.129
66.008
40.096
57.167
63.556
37.643
-22.041
-35.454
-61.367
138.337
165.018
139.105

MOM-X
195.858
158.847
176.167
106.781
154.526
170.766
101.379
-283.566
-376.848
-446.235
596.938
723.781
654.394

MOM-Y
-10.82
-12.93
-15.42
-11.39
-4.388
-4.74
-0.708
1.013
2.012
6.043
-18.33
-22.17
-18.14

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 779.083 + 600.79


= 1379.873 kN

MOM Z
-2.209
186.427
233.17
233.999
-189.961
-237.315
-236.486
-0.789
-0.85
-0.021
-2.745
-3.295
-2.466

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1379.873 / (3.3 x 4.6 )


=

90.901

kN/m

Mxx/Zxx = 195.858 / 11.638


Mxx/Zxx =

16.830

kN/m

Mzz/Zzz = 2.209 / 8.349


Mzz/Zzz =

0.265

kN/m

Maxi.Soil Pressure pmax = 90.901 + 16.83 + 0.265


pmax =

108.00

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 90.901 - 16.83 - 0.265
pmin =

73.81

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
195.88 kN.m
Calculation of Stabilizing Moment
Due to External Load = 779.083 x 3.3 / 2
=
1285.49 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1285.49 + 0 + 375.71 + 615.6
=
2276.8 kN.m
F.O.S. against Overturning = 2276.8 / 195.88
= 11.6234 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

72.7

kN

Total Vertical Load = 1379.87 kN


F.O.S. against Sliding = 1379.873 x 0.5 / 72.7
=
9.5
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
250 5 1.5 (DL+LL)
779.083 51.32299
F3-C4 6 1.2 (DL+LL+EQX)
629.083 41.44157
0
7 1.5 (DL+EQX)
757.016 49.8693
0
8 0.9DL+1.5EQX
457.118 30.11318
0
9 1.2 (DL+LL-EQX)
617.449 40.67516
0
10 1.5 (DL-EQX)
742.474 48.91133
0
11 0.9DL-1.5EQX
442.576 29.1552
0
12 1.2 (DL+LL+EQZ)
587.344 38.69196
0
13 1.5 (DL+EQZ)
704.843 46.43235
0
14 0.9DL+1.5EQZ
404.945 26.67622
0
15 1.2 (DL+LL-EQZ)
659.188 43.42477
0
16 1.5 (DL-EQZ)
794.648 52.34835
0
17 0.9DL-1.5EQZ
494.75 32.59223
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

16.83
13.65
15.14
9.18
13.28
14.68
8.72
24.37
32.39
38.35
51.3
62.2
56.23

0.27
22.33
27.93
28.03
22.76
28.43
28.33
0.1
0.11
0.01
0.33
0.4
0.3

68.423
77.4216
92.9393
67.3232
76.7152
92.0213
66.2052
63.162
78.9323
65.0362
95.0548
114.948
89.1222

140
166
166
166
166
166
166
166
166
166
166
166
166

34.23
5.47
6.8
-7.1
4.64
5.81
-7.9
14.23
13.94
-11.69
-8.21
-10.26
-23.94

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 68.42299 kN/m2
pmax = 114.9484 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
250 5 1.5 (DL+LL)
51.32299 16.83
F3-C4 6 1.2 (DL+LL+EQX)
41.44157 13.65
0
7 1.5 (DL+EQX)
49.8693 15.14
0
8 0.9DL+1.5EQX
30.11318
9.18
0
9 1.2 (DL+LL-EQX)
40.67516 13.28
0
10 1.5 (DL-EQX)
48.91133 14.68
0
11 0.9DL-1.5EQX
29.1552
8.72
0
12 1.2 (DL+LL+EQZ)
38.69196 24.37
0
13 1.5 (DL+EQZ)
46.43235 32.39
0
14 0.9DL+1.5EQZ
26.67622 38.35
0
15 1.2 (DL+LL-EQZ)
43.42477
51.3
0
16 1.5 (DL-EQZ)
52.34835
62.2
0
17 0.9DL-1.5EQZ
32.59223 56.23
Joint

kN/m2

Mzz/Zzz
(3)
0.27
22.33
27.93
28.03
22.76
28.43
28.33
0.1
0.11
0.01
0.33
0.4
0.3

pmin =

1+2+3

1-2+3

-23.94 kN/m2

1-2-3

1+2-3

68.423 34.763
34.223 67.883
77.422 50.122
5.462
32.762
92.94
62.66
6.8
37.08
67.324 48.964
-7.097 11.264
76.716 50.156
4.636
31.196
92.022 62.662
5.802
35.162
66.206 48.766
-7.895
9.546
63.162 14.422
14.222 62.962
78.933 14.153
13.933 78.713
65.037 -11.664 -11.684 65.017
95.055 -7.546
-8.206 94.395
114.949 -9.452 -10.252 114.15
89.123 -23.338 -23.938 88.523

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
250 5 1.5 (DL+LL)
1379.873 90.90072
F3-C4 6 1.2 (DL+LL+EQX)
1229.873 81.0193
0
7 1.5 (DL+EQX)
1357.806 89.44704
0
8 0.9DL+1.5EQX
1057.908 69.69091
0
9 1.2 (DL+LL-EQX)
1218.239 80.2529
0
10 1.5 (DL-EQX)
1343.264 88.48906
0
11 0.9DL-1.5EQX
1043.366 68.73294
0
12 1.2 (DL+LL+EQZ)
1188.134 78.2697
0
13 1.5 (DL+EQZ)
1305.633 86.01008
0
14 0.9DL+1.5EQZ
1005.735 66.25395
0
15 1.2 (DL+LL-EQZ)
1259.978 83.0025
0
16 1.5 (DL-EQZ)
1395.438 91.92609
0
17 0.9DL-1.5EQZ
1095.54 72.16996
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

16.83
13.65
15.14
9.18
13.28
14.68
8.72
24.37
32.39
38.35
51.3
62.2
56.23

0.27
22.33
27.93
28.03
22.76
28.43
28.33
0.1
0.11
0.01
0.33
0.4
0.3

108.001
116.999
132.517
106.901
116.293
131.599
105.783
102.74
118.51
104.614
134.633
154.526
128.7

140
166
166
166
166
166
166
166
166
166
166
166
166

73.81
45.04
46.38
32.49
44.22
45.38
31.69
53.8
53.52
27.9
31.38
29.33
15.64

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 108.0007 kN/m2
pmax = 154.5261 kN/m2
pmin =

73.81 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
250 5 1.5 (DL+LL)
90.90072 16.83
F3-C4 6 1.2 (DL+LL+EQX)
81.0193 13.65
0
7 1.5 (DL+EQX)
89.44704 15.14
0
8 0.9DL+1.5EQX
69.69091
9.18
0
9 1.2 (DL+LL-EQX)
80.2529 13.28
0
10 1.5 (DL-EQX)
88.48906 14.68
0
11 0.9DL-1.5EQX
68.73294
8.72
0
12 1.2 (DL+LL+EQZ)
78.2697 24.37
0
13 1.5 (DL+EQZ)
86.01008 32.39
0
14 0.9DL+1.5EQZ
66.25395 38.35
0
15 1.2 (DL+LL-EQZ)
83.0025
51.3
0
16 1.5 (DL-EQZ)
91.92609
62.2
0
17 0.9DL-1.5EQZ
72.16996 56.23
Joint

Mzz/Zzz
(3)
0.27
22.33
27.93
28.03
22.76
28.43
28.33
0.1
0.11
0.01
0.33
0.4
0.3

pmin =

1+2+3

1-2+3

108.001 74.341
117
89.7
132.518 102.238
106.901 88.541
116.293 89.733
131.6
102.24
105.783 88.343
102.74
54
118.511 53.731
104.614 27.914
134.633 32.033
154.527 30.127
128.7
16.24

15.64

kN/m2

1-2-3

1+2-3

73.801
45.04
46.378
32.481
44.213
45.38
31.683
53.8
53.511
27.894
31.373
29.327
15.64

107.46
72.34
76.658
50.841
70.773
74.74
49.123
102.54
118.29
104.59
133.97
153.73
128.1

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
250
F3-C4
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
195.8705 991.31
6 1.2 (DL+LL+EQX)
244.9232 991.31
7 1.5 (DL+EQX)
292.238 991.31
8 0.9DL+1.5EQX
257.2114 991.31
9 1.2 (DL+LL-EQX)
244.8744 991.31
10 1.5 (DL-EQX)
292.3687 991.31
11 0.9DL-1.5EQX
257.3001 991.31
12 1.2 (DL+LL+EQZ)
283.5671 991.31
13 1.5 (DL+EQZ)
376.849 991.31
14 0.9DL+1.5EQZ
446.235 991.31
15 1.2 (DL+LL-EQZ)
596.9443 991.31
16 1.5 (DL-EQZ)
723.7885 991.31
17 0.9DL-1.5EQZ
654.3986 991.31

1285.49
1037.99
1249.08
754.25
1018.8
1225.09
730.26
969.12
1163
668.16
1087.67
1311.17
816.34

11.63
8.29
7.67
6.79
8.21
7.59
6.7
6.92
5.72
3.72
3.49
3.19
2.77

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
72.69269
106.3697
128.7887
118.0067
106.7165
129.282
118.3292
22.04576
35.4577
61.3671
138.3425
165.0247
139.1092

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.342

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1379.9
1229.9
1357.8
1057.9
1218.2
1343.3
1043.4
1188.1
1305.6
1005.7
1260
1395.4
1095.5

9.5
5.79
5.28
4.49
5.71
5.2
4.41
26.95
18.42
8.2
4.56
4.23
3.94

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 794.648 kN
Punching Shear,P =
794.648 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 726.24 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 726240


=
1.37 x4600
= 115.24 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
154.527

kN/m2

B) One Way Shear


1400
0

1925

154.284

kN/m2

154.193

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

30.127

kN/m2
101.752 kN/m2

154.527

kN/m2

121.543

kN/m2

153.727

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 121.543 - 25 x 0.6 - 18 x ( 2 81.343 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 81.343 x 3.3 x 1.4
= 375.8047 kN
At Width
Maximum Pressure = 154.284 - 25 x 0.6 - 18 x ( 2 114.084 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 114.084 x 4.6 x 0.875
= 459.1881 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 459.1881 kN


Corresponding Length =
4600
mm
% Ast =

0.342

Allowable Shear Stress =


0.4168 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4168 x 1
2
=
0.4168 N/mm
Depth Required = 459188.1
0.4168 x 4600
=
315
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm

Min. Length from column face to


edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 154.527
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
114.947 kN/m2
1.925

Bending Moment = 114.947 x 1.925 x 1.925 / 2


= 212.98 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1768.67
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
177
175

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1794.29

mm

Provide 20 mm dia Bars @ 175 mm spacing bothways

i.e.0.342%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 175 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C5

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
251
F3-C5

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
1.15
782.233
6 1.2 (DL+LL+EQX)
-87.662 625.103
7 1.5 (DL+EQX)
-109.656 751.794
8 0.9DL+1.5EQX
-110.084 450.735
9 1.2 (DL+LL-EQX)
89.502
626.47
10 1.5 (DL-EQX)
111.799 753.502
11 0.9DL-1.5EQX
111.37
452.443
12 1.2 (DL+LL+EQZ)
0.526
587.821
13 1.5 (DL+EQZ)
0.578
705.19
14 0.9DL+1.5EQZ
0.15
404.131
15 1.2 (DL+LL-EQZ)
1.315
663.752
16 1.5 (DL-EQZ)
1.565
800.105
17 0.9DL-1.5EQZ
1.136
499.046

kN - m)
FORCE-Z
82.439
65.897
73.774
44.238
66.005
73.908
44.372
-21.988
-36.082
-65.619
153.89
183.765
154.229

MOM-X
226.142
180.882
202.175
121.289
180.945
202.254
121.368
-299.12
-397.827
-478.713
660.947
802.256
721.37

MOM-Y
-0.371
-5.425
-6.851
-6.675
4.832
5.971
6.147
2.705
3.312
3.488
-3.298
-4.192
-4.016

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 782.233 + 600.79


= 1383.023 kN

MOM Z
-2.27
185.555
232.094
232.942
-189.187
-236.334
-235.486
-0.925
-1.007
-0.159
-2.706
-3.233
-2.385

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1383.023 / (3.3 x 4.6 )


=

91.108

kN/m

Mxx/Zxx = 226.142 / 11.638


Mxx/Zxx =

19.432

kN/m

Mzz/Zzz = 2.27 / 8.349


Mzz/Zzz =

0.272

kN/m

Maxi.Soil Pressure pmax = 91.108 + 19.432 + 0.272


pmax =

110.82

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 91.108 - 19.432 - 0.272
pmin =

71.41

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
226.16 kN.m
Calculation of Stabilizing Moment
Due to External Load = 782.233 x 3.3 / 2
=
1290.69 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1290.69 + 0 + 375.71 + 615.6
=
2282 kN.m
F.O.S. against Overturning = 2282 / 226.16
= 10.0902 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

82.45

kN

Total Vertical Load = 1383.02 kN


F.O.S. against Sliding = 1383.023 x 0.5 / 82.45
=
8.39
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
251 5 1.5 (DL+LL)
782.233 51.5305
F3-C5 6 1.2 (DL+LL+EQX)
625.103 41.17938
0
7 1.5 (DL+EQX)
751.794 49.5253
0
8 0.9DL+1.5EQX
450.735 29.69269
0
9 1.2 (DL+LL-EQX)
626.47 41.26943
0
10 1.5 (DL-EQX)
753.502 49.63781
0
11 0.9DL-1.5EQX
452.443 29.8052
0
12 1.2 (DL+LL+EQZ)
587.821 38.72339
0
13 1.5 (DL+EQZ)
705.19 46.4552
0
14 0.9DL+1.5EQZ
404.131 26.6226
0
15 1.2 (DL+LL-EQZ)
663.752 43.72543
0
16 1.5 (DL-EQZ)
800.105 52.70784
0
17 0.9DL-1.5EQZ
499.046 32.87523
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

19.44
15.55
17.38
10.43
15.55
17.38
10.43
25.71
34.19
41.14
56.8
68.94
61.99

0.28
22.23
27.8
27.91
22.66
28.31
28.21
0.12
0.13
0.02
0.33
0.39
0.29

71.2505
78.9594
94.7053
68.0327
79.4794
95.3278
68.4452
64.5534
80.7752
67.7826
100.855
122.038
95.1552

140
166
166
166
166
166
166
166
166
166
166
166
166

31.82
3.4
4.35
-8.65
3.06
3.95
-8.84
12.9
12.14
-14.54
-13.41
-16.63
-29.41

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 71.2505 kN/m2
pmax = 122.0378 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
251 5 1.5 (DL+LL)
51.5305 19.44
F3-C5 6 1.2 (DL+LL+EQX)
41.17938 15.55
0
7 1.5 (DL+EQX)
49.5253 17.38
0
8 0.9DL+1.5EQX
29.69269 10.43
0
9 1.2 (DL+LL-EQX)
41.26943 15.55
0
10 1.5 (DL-EQX)
49.63781 17.38
0
11 0.9DL-1.5EQX
29.8052 10.43
0
12 1.2 (DL+LL+EQZ)
38.72339 25.71
0
13 1.5 (DL+EQZ)
46.4552 34.19
0
14 0.9DL+1.5EQZ
26.6226 41.14
0
15 1.2 (DL+LL-EQZ)
43.72543
56.8
0
16 1.5 (DL-EQZ)
52.70784 68.94
0
17 0.9DL-1.5EQZ
32.87523 61.99
Joint

kN/m2

Mzz/Zzz
(3)
0.28
22.23
27.8
27.91
22.66
28.31
28.21
0.12
0.13
0.02
0.33
0.39
0.29

pmin =

-29.41 kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

71.251
78.96
94.706
68.033
79.48
95.328
68.446
64.554
80.776
67.783
100.856
122.038
95.156

32.371
47.86
59.946
47.173
48.38
60.568
47.586
13.134
12.396
-14.498
-12.745
-15.843
-28.825

31.811
3.4
4.346
-8.648
3.06
3.948
-8.835
12.894
12.136
-14.538
-13.405
-16.623
-29.405

70.691
34.5
39.106
12.213
34.16
38.708
12.026
64.314
80.516
67.743
100.2
121.26
94.576

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
251 5 1.5 (DL+LL)
1383.023 91.10823
F3-C5 6 1.2 (DL+LL+EQX)
1225.893 80.75711
0
7 1.5 (DL+EQX)
1352.584 89.10303
0
8 0.9DL+1.5EQX
1051.525 69.27042
0
9 1.2 (DL+LL-EQX)
1227.26 80.84717
0
10 1.5 (DL-EQX)
1354.292 89.21555
0
11 0.9DL-1.5EQX
1053.233 69.38294
0
12 1.2 (DL+LL+EQZ)
1188.611 78.30112
0
13 1.5 (DL+EQZ)
1305.98 86.03294
0
14 0.9DL+1.5EQZ
1004.921 66.20033
0
15 1.2 (DL+LL-EQZ)
1264.542 83.30316
0
16 1.5 (DL-EQZ)
1400.895 92.28557
0
17 0.9DL-1.5EQZ
1099.836 72.45296
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

19.44
15.55
17.38
10.43
15.55
17.38
10.43
25.71
34.19
41.14
56.8
68.94
61.99

0.28
22.23
27.8
27.91
22.66
28.31
28.21
0.12
0.13
0.02
0.33
0.39
0.29

110.828
118.537
134.283
107.61
119.057
134.906
108.023
104.131
120.353
107.36
140.433
161.616
134.733

140
166
166
166
166
166
166
166
166
166
166
166
166

71.39
42.98
43.93
30.94
42.64
43.53
30.75
52.48
51.72
25.05
26.18
22.96
10.18

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 110.8282 kN/m2
pmax = 161.6156 kN/m2
pmin =

71.39 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
251 5 1.5 (DL+LL)
91.10823 19.44
F3-C5 6 1.2 (DL+LL+EQX)
80.75711 15.55
0
7 1.5 (DL+EQX)
89.10303 17.38
0
8 0.9DL+1.5EQX
69.27042 10.43
0
9 1.2 (DL+LL-EQX)
80.84717 15.55
0
10 1.5 (DL-EQX)
89.21555 17.38
0
11 0.9DL-1.5EQX
69.38294 10.43
0
12 1.2 (DL+LL+EQZ)
78.30112 25.71
0
13 1.5 (DL+EQZ)
86.03294 34.19
0
14 0.9DL+1.5EQZ
66.20033 41.14
0
15 1.2 (DL+LL-EQZ)
83.30316
56.8
0
16 1.5 (DL-EQZ)
92.28557 68.94
0
17 0.9DL-1.5EQZ
72.45296 61.99
Joint

Mzz/Zzz
(3)
0.28
22.23
27.8
27.91
22.66
28.31
28.21
0.12
0.13
0.02
0.33
0.39
0.29

pmin =

1+2+3

1-2+3

110.829 71.949
118.538 87.438
134.284 99.524
107.611 86.751
119.058 87.958
134.906 100.146
108.023 87.163
104.132 52.712
120.353 51.973
107.361 25.081
140.434 26.834
161.616 23.736
134.733 10.753

10.18

kN/m2

1-2-3

1+2-3

71.389
42.978
43.924
30.931
42.638
43.526
30.743
52.472
51.713
25.041
26.174
22.956
10.173

110.27
74.078
78.684
51.791
73.738
78.286
51.603
103.89
120.09
107.32
139.77
160.84
134.15

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
251
F3-C5
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
226.1534 991.31
6 1.2 (DL+LL+EQX)
259.1312 991.31
7 1.5 (DL+EQX)
307.8025 991.31
8 0.9DL+1.5EQX
262.6271 991.31
9 1.2 (DL+LL-EQX)
261.7877 991.31
10 1.5 (DL-EQX)
311.0634 991.31
11 0.9DL-1.5EQX
264.9223 991.31
12 1.2 (DL+LL+EQZ)
299.1214 991.31
13 1.5 (DL+EQZ)
397.8283 991.31
14 0.9DL+1.5EQZ
478.713 991.31
15 1.2 (DL+LL-EQZ)
660.9525 991.31
16 1.5 (DL-EQZ)
802.2625 991.31
17 0.9DL-1.5EQZ
721.3739 991.31

1290.69
1031.42
1240.47
743.72
1033.68
1243.28
746.54
969.91
1163.57
666.82
1095.2
1320.18
823.43

10.1
7.81
7.26
6.61
7.74
7.19
6.56
6.56
5.42
3.47
3.16
2.89
2.52

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
82.44702
109.6679
132.1629
118.6402
111.2082
134.0202
119.8839
21.99429
36.08663
65.61917
153.8956
183.7717
154.2332

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.362

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1383
1225.9
1352.6
1051.5
1227.3
1354.3
1053.2
1188.6
1306
1004.9
1264.5
1400.9
1099.8

8.39
5.59
5.12
4.44
5.52
5.06
4.4
27.03
18.1
7.66
4.11
3.82
3.57

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 800.105 kN
Punching Shear,P =
800.105 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 731.23 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 731230


=
1.37 x4600
= 116.03 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
161.616

kN/m2

B) One Way Shear


1400
0

1925

161.379

kN/m2

161.29

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

23.736

kN/m2
103.122 kN/m2

161.616

kN/m2

125.057

kN/m2

160.836

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 125.057 - 25 x 0.6 - 18 x ( 2 84.857 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 84.857 x 3.3 x 1.4
= 392.0393 kN
At Width
Maximum Pressure = 161.379 - 25 x 0.6 - 18 x ( 2 121.179 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 121.179 x 4.6 x 0.875
= 487.7455 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 487.74548 kN


Corresponding Length =
4600
mm
% Ast =

0.362

Allowable Shear Stress =


0.4272 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4272 x 1
2

=
0.4272 N/mm
Depth Required = 487745.48
0.4272 x 4600
=
324
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 161.616
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
122.036 kN/m2
1.925

Bending Moment = 122.036 x 1.925 x 1.925 / 2


= 226.11 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1883.69
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
166
165

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1903.03

mm

Provide 20 mm dia Bars @ 165 mm spacing bothways

i.e.0.363%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 165 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C6

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
252
F3-C6

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
1.102
782.687
6 1.2 (DL+LL+EQX)
-87.618 626.505
7 1.5 (DL+EQX)
-109.576 753.654
8 0.9DL+1.5EQX
-109.995 452.37
9 1.2 (DL+LL-EQX)
89.382
625.794
10 1.5 (DL-EQX)
111.674 752.764
11 0.9DL-1.5EQX
111.254
451.48
12 1.2 (DL+LL+EQZ)
0.579
587.084
13 1.5 (DL+EQZ)
0.671
704.377
14 0.9DL+1.5EQZ
0.251
403.094
15 1.2 (DL+LL-EQZ)
1.184
665.215
16 1.5 (DL-EQZ)
1.427
802.04
17 0.9DL-1.5EQZ
1.008
500.757

kN - m)
FORCE-Z
82.662
66.164
74.163
44.515
66.096
74.077
44.429
-23.6
-38.043
-67.691
155.86
186.282
156.634

MOM-X
228.97
183.263
205.318
123.235
183.089
205.1
123.017
-308.672
-409.6
-491.684
675.024
820.019
737.935

MOM-Y
-0.586
-5.586
-6.954
-6.731
4.648
5.838
6.062
0.522
0.68
0.904
-1.459
-1.796
-1.573

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 782.687 + 600.79


= 1383.477 kN

MOM Z
-2.189
185.536
232.035
232.864
-189.038
-236.183
-235.353
-1.067
-1.219
-0.389
-2.435
-2.929
-2.1

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1383.477 / (3.3 x 4.6 )


=

91.138

kN/m

Mxx/Zxx = 228.97 / 11.638


Mxx/Zxx =

19.675

kN/m

Mzz/Zzz = 2.189 / 8.349


Mzz/Zzz =

0.263

kN/m

Maxi.Soil Pressure pmax = 91.138 + 19.675 + 0.263


pmax =

111.08

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 91.138 - 19.675 - 0.263
pmin =

71.20

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
228.99 kN.m
Calculation of Stabilizing Moment
Due to External Load = 782.687 x 3.3 / 2
=
1291.44 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1291.44 + 0 + 375.71 + 615.6
=
2282.75 kN.m
F.O.S. against Overturning = 2282.75 / 228.99
= 9.96878 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

82.67

kN

Total Vertical Load = 1383.48 kN


F.O.S. against Sliding = 1383.477 x 0.5 / 82.67
=
8.37
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
252 5 1.5 (DL+LL)
782.687 51.56041
F3-C6 6 1.2 (DL+LL+EQX)
626.505 41.27174
0
7 1.5 (DL+EQX)
753.654 49.64783
0
8 0.9DL+1.5EQX
452.37 29.8004
0
9 1.2 (DL+LL-EQX)
625.794 41.2249
0
10 1.5 (DL-EQX)
752.764 49.5892
0
11 0.9DL-1.5EQX
451.48 29.74177
0
12 1.2 (DL+LL+EQZ)
587.084 38.67484
0
13 1.5 (DL+EQZ)
704.377 46.40165
0
14 0.9DL+1.5EQZ
403.094 26.55428
0
15 1.2 (DL+LL-EQZ)
665.215 43.82181
0
16 1.5 (DL-EQZ)
802.04 52.83531
0
17 0.9DL-1.5EQZ
500.757 32.98794
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

19.68
15.75
17.65
10.59
15.74
17.63
10.58
26.53
35.2
42.25
58.01
70.47
63.41

0.27
22.23
27.8
27.9
22.65
28.29
28.19
0.13
0.15
0.05
0.3
0.36
0.26

71.5104
79.2517
95.0978
68.2904
79.6149
95.5092
68.5118
65.3348
81.7516
68.8543
102.132
123.665
96.6579

140
166
166
166
166
166
166
166
166
166
166
166
166

31.62
3.3
4.2
-8.69
2.84
3.67
-9.03
12.02
11.06
-15.75
-14.49
-18
-30.69

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 71.51041 kN/m2
pmax = 123.6653 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
252 5 1.5 (DL+LL)
51.56041 19.68
F3-C6 6 1.2 (DL+LL+EQX)
41.27174 15.75
0
7 1.5 (DL+EQX)
49.64783 17.65
0
8 0.9DL+1.5EQX
29.8004 10.59
0
9 1.2 (DL+LL-EQX)
41.2249 15.74
0
10 1.5 (DL-EQX)
49.5892 17.63
0
11 0.9DL-1.5EQX
29.74177 10.58
0
12 1.2 (DL+LL+EQZ)
38.67484 26.53
0
13 1.5 (DL+EQZ)
46.40165
35.2
0
14 0.9DL+1.5EQZ
26.55428 42.25
0
15 1.2 (DL+LL-EQZ)
43.82181 58.01
0
16 1.5 (DL-EQZ)
52.83531 70.47
0
17 0.9DL-1.5EQZ
32.98794 63.41
Joint

kN/m2

Mzz/Zzz
(3)
0.27
22.23
27.8
27.9
22.65
28.29
28.19
0.13
0.15
0.05
0.3
0.36
0.26

pmin =

-30.69 kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

71.511
79.252
95.098
68.291
79.615
95.51
68.512
65.335
81.752
68.855
102.132
123.666
96.658

32.151
47.752
59.798
47.111
48.135
60.25
47.352
12.275
11.352
-15.646
-13.889
-17.275
-30.163

31.611
3.292
4.198
-8.69
2.835
3.67
-9.029
12.015
11.052
-15.746
-14.489
-17.995
-30.683

70.971
34.792
39.498
12.491
34.315
38.93
12.132
65.075
81.452
68.755
101.53
122.95
96.138

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
252 5 1.5 (DL+LL)
1383.477 91.13814
F3-C6 6 1.2 (DL+LL+EQX)
1227.295 80.84947
0
7 1.5 (DL+EQX)
1354.444 89.22556
0
8 0.9DL+1.5EQX
1053.16 69.37813
0
9 1.2 (DL+LL-EQX)
1226.584 80.80264
0
10 1.5 (DL-EQX)
1353.554 89.16693
0
11 0.9DL-1.5EQX
1052.27 69.3195
0
12 1.2 (DL+LL+EQZ)
1187.874 78.25257
0
13 1.5 (DL+EQZ)
1305.167 85.97938
0
14 0.9DL+1.5EQZ
1003.884 66.13202
0
15 1.2 (DL+LL-EQZ)
1266.005 83.39954
0
16 1.5 (DL-EQZ)
1402.83 92.41304
0
17 0.9DL-1.5EQZ
1101.547 72.56568
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

19.68
15.75
17.65
10.59
15.74
17.63
10.58
26.53
35.2
42.25
58.01
70.47
63.41

0.27
22.23
27.8
27.9
22.65
28.29
28.19
0.13
0.15
0.05
0.3
0.36
0.26

111.088
118.829
134.676
107.868
119.193
135.087
108.089
104.913
121.329
108.432
141.71
163.243
136.236

140
166
166
166
166
166
166
166
166
166
166
166
166

71.19
42.87
43.78
30.89
42.42
43.25
30.55
51.6
50.63
23.84
25.09
21.59
8.9

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 111.0881 kN/m2
pmax = 163.243 kN/m2
pmin =

71.19 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
252 5 1.5 (DL+LL)
91.13814 19.68
F3-C6 6 1.2 (DL+LL+EQX)
80.84947 15.75
0
7 1.5 (DL+EQX)
89.22556 17.65
0
8 0.9DL+1.5EQX
69.37813 10.59
0
9 1.2 (DL+LL-EQX)
80.80264 15.74
0
10 1.5 (DL-EQX)
89.16693 17.63
0
11 0.9DL-1.5EQX
69.3195 10.58
0
12 1.2 (DL+LL+EQZ)
78.25257 26.53
0
13 1.5 (DL+EQZ)
85.97938
35.2
0
14 0.9DL+1.5EQZ
66.13202 42.25
0
15 1.2 (DL+LL-EQZ)
83.39954 58.01
0
16 1.5 (DL-EQZ)
92.41304 70.47
0
17 0.9DL-1.5EQZ
72.56568 63.41
Joint

Mzz/Zzz
(3)
0.27
22.23
27.8
27.9
22.65
28.29
28.19
0.13
0.15
0.05
0.3
0.36
0.26

pmin =

8.9

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

111.089
118.83
134.676
107.869
119.193
135.087
108.09
104.913
121.33
108.433
141.71
163.244
136.236

71.729
87.33
99.376
86.689
87.713
99.827
86.93
51.853
50.93
23.933
25.69
22.304
9.416

71.189
42.87
43.776
30.889
42.413
43.247
30.55
51.593
50.63
23.833
25.09
21.584
8.896

110.55
74.37
79.076
52.069
73.893
78.507
51.71
104.65
121.03
108.33
141.11
162.52
135.72

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
252
F3-C6
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
228.9805 991.31
6 1.2 (DL+LL+EQX)
260.7852 991.31
7 1.5 (DL+EQX)
309.8318 991.31
8 0.9DL+1.5EQX
263.4625 991.31
9 1.2 (DL+LL-EQX)
263.1671 991.31
10 1.5 (DL-EQX)
312.8073 991.31
11 0.9DL-1.5EQX
265.564 991.31
12 1.2 (DL+LL+EQZ)
308.6738 991.31
13 1.5 (DL+EQZ)
409.6018 991.31
14 0.9DL+1.5EQZ
491.6842 991.31
15 1.2 (DL+LL-EQZ)
675.0284 991.31
16 1.5 (DL-EQZ)
820.0242 991.31
17 0.9DL-1.5EQZ
737.938 991.31

1291.44
1033.74
1243.53
746.42
1032.57
1242.07
744.95
968.69
1162.23
665.11
1097.61
1323.37
826.25

9.97
7.77
7.22
6.6
7.7
7.14
6.54
6.35
5.26
3.37
3.1
2.83
2.47

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
82.66935
109.7934
132.3142
118.6612
111.1657
134.0093
119.7973
23.6071
38.04892
67.69147
155.8645
186.2875
156.6372

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.374

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1383.5
1227.3
1354.4
1053.2
1226.6
1353.6
1052.3
1187.9
1305.2
1003.9
1266
1402.8
1101.5

8.37
5.59
5.12
4.44
5.52
5.06
4.4
25.16
17.16
7.42
4.07
3.77
3.52

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column =
802.04 kN
Punching Shear,P =
802.04 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P =
733
kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 733000


=
1.37 x4600
= 116.31 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
163.244

kN/m2

B) One Way Shear


1400
0

1925

163.025

kN/m2

162.943

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

22.304

kN/m2
103.452 kN/m2

163.244

kN/m2

125.874

kN/m2

162.524

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 125.874 - 25 x 0.6 - 18 x ( 2 85.674 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 85.674 x 3.3 x 1.4
= 395.8139 kN
At Width
Maximum Pressure = 163.025 - 25 x 0.6 - 18 x ( 2 122.825 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 122.825 x 4.6 x 0.875
= 494.3706 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 494.37063 kN


Corresponding Length =
4600
mm
% Ast =

0.374

Allowable Shear Stress =


0.4324 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4324 x 1
2

=
0.4324 N/mm
Depth Required = 494370.63
0.4324 x 4600
=
324
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 163.244
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
123.664 kN/m2
1.925

Bending Moment = 123.664 x 1.925 x 1.925 / 2


= 229.13 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1910.26
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
164
160

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1962.5

mm

Provide 20 mm dia Bars @ 160 mm spacing bothways

i.e.0.374%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 160 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C7

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
253
F3-C7

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
0.291
766.713
6 1.2 (DL+LL+EQX)
-89.015 602.218
7 1.5 (DL+EQX)
-111.365 724.21
8 0.9DL+1.5EQX
-111.443 428.95
9 1.2 (DL+LL-EQX)
89.48
624.522
10 1.5 (DL-EQX)
111.754 752.089
11 0.9DL-1.5EQX
111.677 456.829
12 1.2 (DL+LL+EQZ)
-0.006
573.598
13 1.5 (DL+EQZ)
-0.104
688.435
14 0.9DL+1.5EQZ
-0.182
393.175
15 1.2 (DL+LL-EQZ)
0.471
653.142
16 1.5 (DL-EQZ)
0.493
787.865
17 0.9DL-1.5EQZ
0.415
492.605

kN - m)
FORCE-Z
74.043
59.051
66.201
39.629
59.418
66.66
40.088
-31.185
-46.594
-73.166
149.654
179.455
152.882

MOM-X
210.134
167.748
188.043
112.646
168.467
188.943
113.546
-329.191
-433.13
-508.527
665.406
810.116
734.719

MOM-Y
8.143
1.705
1.275
-1.639
11.323
13.298
10.383
7.793
8.885
5.97
5.236
5.688
2.774

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 766.713 + 600.79


= 1367.503 kN

MOM Z
-1.257
187.184
234.139
234.578
-189.196
-236.336
-235.897
-0.5
-0.467
-0.027
-1.511
-1.73
-1.291

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1367.503 / (3.3 x 4.6 )


=

90.086

kN/m

Mxx/Zxx = 210.134 / 11.638


Mxx/Zxx =

18.056

kN/m

Mzz/Zzz = 1.257 / 8.349


Mzz/Zzz =

0.151

kN/m

Maxi.Soil Pressure pmax = 90.086 + 18.056 + 0.151


pmax =

108.30

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 90.086 - 18.056 - 0.151
pmin =

71.88

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
210.14 kN.m
Calculation of Stabilizing Moment
Due to External Load = 766.713 x 3.3 / 2
=
1265.08 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1265.08 + 0 + 375.71 + 615.6
=
2256.39 kN.m
F.O.S. against Overturning = 2256.39 / 210.14
= 10.7376 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

74.05

kN

Total Vertical Load = 1367.5 kN


F.O.S. against Sliding = 1367.503 x 0.5 / 74.05
=
9.24
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
253 5 1.5 (DL+LL)
766.713 50.5081
F3-C7 6 1.2 (DL+LL+EQX)
602.218 39.67181
0
7 1.5 (DL+EQX)
724.21 47.70817
0
8 0.9DL+1.5EQX
428.95 28.25758
0
9 1.2 (DL+LL-EQX)
624.522 41.14111
0
10 1.5 (DL-EQX)
752.089 49.54473
0
11 0.9DL-1.5EQX
456.829 30.09414
0
12 1.2 (DL+LL+EQZ)
573.598 37.78643
0
13 1.5 (DL+EQZ)
688.435 45.35145
0
14 0.9DL+1.5EQZ
393.175 25.90086
0
15 1.2 (DL+LL-EQZ)
653.142 43.02648
0
16 1.5 (DL-EQZ)
787.865 51.90152
0
17 0.9DL-1.5EQZ
492.605 32.45092
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

18.06
14.42
16.16
9.68
14.48
16.24
9.76
28.29
37.22
43.7
57.18
69.61
63.14

0.16
22.42
28.05
28.1
22.67
28.31
28.26
0.06
0.06
0.01
0.19
0.21
0.16

68.7281
76.5118
91.9182
66.0376
78.2911
94.0947
68.1141
66.1364
82.6314
69.6109
100.396
121.722
95.7509

140
166
166
166
166
166
166
166
166
166
166
166
166

32.29
2.84
3.5
-9.53
4
5
-7.93
9.44
8.08
-17.81
-14.35
-17.92
-30.85

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 68.7281 kN/m2
pmax = 121.7215 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
253 5 1.5 (DL+LL)
50.5081 18.06
F3-C7 6 1.2 (DL+LL+EQX)
39.67181 14.42
0
7 1.5 (DL+EQX)
47.70817 16.16
0
8 0.9DL+1.5EQX
28.25758
9.68
0
9 1.2 (DL+LL-EQX)
41.14111 14.48
0
10 1.5 (DL-EQX)
49.54473 16.24
0
11 0.9DL-1.5EQX
30.09414
9.76
0
12 1.2 (DL+LL+EQZ)
37.78643 28.29
0
13 1.5 (DL+EQZ)
45.35145 37.22
0
14 0.9DL+1.5EQZ
25.90086
43.7
0
15 1.2 (DL+LL-EQZ)
43.02648 57.18
0
16 1.5 (DL-EQZ)
51.90152 69.61
0
17 0.9DL-1.5EQZ
32.45092 63.14
Joint

kN/m2

Mzz/Zzz
(3)
0.16
22.42
28.05
28.1
22.67
28.31
28.26
0.06
0.06
0.01
0.19
0.21
0.16

pmin =

1+2+3

1-2+3

-30.85 kN/m2

1-2-3

1+2-3

68.729 32.609
32.289 68.409
76.512 47.672
2.832
31.672
91.919 59.599
3.499
35.819
66.038 46.678
-9.523
9.838
78.292 49.332
3.992
32.952
94.095 61.615
4.995
37.475
68.115 48.595
-7.926 11.595
66.137
9.557
9.437
66.017
82.632
8.192
8.072
82.512
69.611 -17.79
-17.81 69.591
100.397 -13.964 -14.344 100.02
121.722 -17.499 -17.919 121.3
95.751 -30.53
-30.85 95.431

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
253 5 1.5 (DL+LL)
1367.503 90.08584
F3-C7 6 1.2 (DL+LL+EQX)
1203.008 79.24954
0
7 1.5 (DL+EQX)
1325
87.2859
0
8 0.9DL+1.5EQX
1029.74 67.83531
0
9 1.2 (DL+LL-EQX)
1225.312 80.71884
0
10 1.5 (DL-EQX)
1352.879 89.12246
0
11 0.9DL-1.5EQX
1057.619 69.67187
0
12 1.2 (DL+LL+EQZ)
1174.388 77.36416
0
13 1.5 (DL+EQZ)
1289.225 84.92918
0
14 0.9DL+1.5EQZ
993.965 65.47859
0
15 1.2 (DL+LL-EQZ)
1253.932 82.60422
0
16 1.5 (DL-EQZ)
1388.655 91.47925
0
17 0.9DL-1.5EQZ
1093.395 72.02866
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

18.06
14.42
16.16
9.68
14.48
16.24
9.76
28.29
37.22
43.7
57.18
69.61
63.14

0.16
22.42
28.05
28.1
22.67
28.31
28.26
0.06
0.06
0.01
0.19
0.21
0.16

108.306
116.09
131.496
105.615
117.869
133.672
107.692
105.714
122.209
109.189
139.974
161.299
135.329

140
166
166
166
166
166
166
166
166
166
166
166
166

71.87
42.41
43.08
30.06
43.57
44.58
31.66
49.02
47.65
21.77
25.24
21.66
8.73

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 108.3058 kN/m2
pmax = 161.2992 kN/m2
pmin =

71.87 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
253 5 1.5 (DL+LL)
90.08584 18.06
F3-C7 6 1.2 (DL+LL+EQX)
79.24954 14.42
0
7 1.5 (DL+EQX)
87.2859 16.16
0
8 0.9DL+1.5EQX
67.83531
9.68
0
9 1.2 (DL+LL-EQX)
80.71884 14.48
0
10 1.5 (DL-EQX)
89.12246 16.24
0
11 0.9DL-1.5EQX
69.67187
9.76
0
12 1.2 (DL+LL+EQZ)
77.36416 28.29
0
13 1.5 (DL+EQZ)
84.92918 37.22
0
14 0.9DL+1.5EQZ
65.47859
43.7
0
15 1.2 (DL+LL-EQZ)
82.60422 57.18
0
16 1.5 (DL-EQZ)
91.47925 69.61
0
17 0.9DL-1.5EQZ
72.02866 63.14
Joint

Mzz/Zzz
(3)
0.16
22.42
28.05
28.1
22.67
28.31
28.26
0.06
0.06
0.01
0.19
0.21
0.16

pmin =

1+2+3

1-2+3

108.306 72.186
116.09
87.25
131.496 99.176
105.616 86.256
117.869 88.909
133.673 101.193
107.692 88.172
105.715 49.135
122.21
47.77
109.189 21.789
139.975 25.615
161.3
22.08
135.329 9.049

8.73

kN/m2

1-2-3

1+2-3

71.866
42.41
43.076
30.056
43.569
44.573
31.652
49.015
47.65
21.769
25.235
21.66
8.729

107.99
71.25
75.396
49.416
72.529
77.053
51.172
105.6
122.09
109.17
139.6
160.88
135.01

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
253
F3-C7
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
210.1378 991.31
6 1.2 (DL+LL+EQX)
251.3508 991.31
7 1.5 (DL+EQX)
300.3019 991.31
8 0.9DL+1.5EQX
260.2229 991.31
9 1.2 (DL+LL-EQX)
253.3303 991.31
10 1.5 (DL-EQX)
302.5792 991.31
11 0.9DL-1.5EQX
261.8016 991.31
12 1.2 (DL+LL+EQZ)
329.1914 991.31
13 1.5 (DL+EQZ)
433.1303 991.31
14 0.9DL+1.5EQZ
508.527 991.31
15 1.2 (DL+LL-EQZ)
665.4077 991.31
16 1.5 (DL-EQZ)
810.1178 991.31
17 0.9DL-1.5EQZ
734.7201 991.31

1265.08
993.66
1194.95
707.77
1030.47
1240.95
753.77
946.44
1135.92
648.74
1077.69
1299.98
812.8

10.74
7.9
7.29
6.53
7.99
7.38
6.67
5.89
4.92
3.23
3.11
2.83
2.46

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
74.04357
106.8208
129.5559
118.2793
107.4112
130.125
118.6541
31.185
46.59412
73.16623
149.6547
179.4557
152.8826

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.362

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1367.5
1203
1325
1029.7
1225.3
1352.9
1057.6
1174.4
1289.2
993.97
1253.9
1388.7
1093.4

9.24
5.64
5.12
4.36
5.71
5.2
4.46
18.83
13.84
6.8
4.19
3.87
3.58

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 787.865 kN
Punching Shear,P =
787.865 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 720.04 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 720040


=
1.37 x4600
= 114.26 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
161.3

kN/m2

B) One Way Shear


1400
0

1925

161.173

kN/m2

161.125

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

22.08

kN/m2
102.237 kN/m2

161.3

kN/m2

124.386

kN/m2

160.88

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 124.386 - 25 x 0.6 - 18 x ( 2 84.186 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 84.186 x 3.3 x 1.4
= 388.9393 kN
At Width
Maximum Pressure = 161.173 - 25 x 0.6 - 18 x ( 2 120.973 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 120.973 x 4.6 x 0.875
= 486.9163 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 486.91633 kN


Corresponding Length =
4600
mm
% Ast =

0.362

Allowable Shear Stress =


0.4272 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4272 x 1
2

=
0.4272 N/mm
Depth Required = 486916.33
0.4272 x 4600
=
323
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure =
161.3
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
121.72 kN/m2
1.925

Bending Moment = 121.72 x 1.925 x 1.925 / 2


= 225.52 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1878.51
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
167
165

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1903.03

mm

Provide 20 mm dia Bars @ 165 mm spacing bothways

i.e.0.363%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 165 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C8

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
254
F3-C8

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
7.058
925.333
6 1.2 (DL+LL+EQX)
-81.047 787.943
7 1.5 (DL+EQX)
-101.275 951.378
8 0.9DL+1.5EQX
-104.112 594.665
9 1.2 (DL+LL-EQX)
92.339
692.59
10 1.5 (DL-EQX)
115.458 832.186
11 0.9DL-1.5EQX
112.621 475.473
12 1.2 (DL+LL+EQZ)
5.529
694.23
13 1.5 (DL+EQZ)
6.944
834.236
14 0.9DL+1.5EQZ
4.108
477.523
15 1.2 (DL+LL-EQZ)
5.764
786.303
16 1.5 (DL-EQZ)
7.238
949.328
17 0.9DL-1.5EQZ
4.402
592.615

kN - m)
FORCE-Z
-50.983
-40.731
-45.404
-27.214
-40.842
-45.542
-27.353
-130.03
-157.03
-138.84
48.46
66.085
84.274

MOM-X
-38.051
-30.214
-33.518
-19.997
-30.668
-34.084
-20.564
-535.517
-665.146
-651.625
474.635
597.544
611.064

MOM-Y
2.347
-3.73
-4.841
-5.708
7.485
9.178
8.311
4.719
5.721
4.853
-0.964
-1.383
-2.251

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 925.333 + 600.79


= 1526.123 kN

MOM Z
-8.938
178.236
222.805
226.376
-192.537
-240.662
-237.09
-6.886
-8.598
-5.027
-7.414
-9.259
-5.687

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1526.123 / (3.3 x 4.6 )


=

100.535

kN/m

Mxx/Zxx = 38.051 / 11.638


Mxx/Zxx =

3.270

kN/m

Mzz/Zzz = 8.938 / 8.349


Mzz/Zzz =

1.071

kN/m

Maxi.Soil Pressure pmax = 100.535 + 3.27 + 1.071


pmax =

104.88

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 100.535 - 3.27 - 1.071
pmin =

96.20

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
39.09
kN.m
Calculation of Stabilizing Moment
Due to External Load = 925.333 x 3.3 / 2
=
1526.8 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1526.8 + 0 + 375.71 + 615.6
=
2518.11 kN.m
F.O.S. against Overturning = 2518.11 / 39.09
= 64.4183 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

51.47

kN

Total Vertical Load = 1526.12 kN


F.O.S. against Sliding = 1526.123 x 0.5 / 51.47
= 14.83
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
254 5 1.5 (DL+LL)
925.333 60.95738
F3-C8 6 1.2 (DL+LL+EQX)
787.943 51.90665
0
7 1.5 (DL+EQX)
951.378 62.67312
0
8 0.9DL+1.5EQX
594.665 39.17424
0
9 1.2 (DL+LL-EQX)
692.59 45.62516
0
10 1.5 (DL-EQX)
832.186 54.82121
0
11 0.9DL-1.5EQX
475.473 31.32233
0
12 1.2 (DL+LL+EQZ)
694.23 45.7332
0
13 1.5 (DL+EQZ)
834.236 54.95626
0
14 0.9DL+1.5EQZ
477.523 31.45738
0
15 1.2 (DL+LL-EQZ)
786.303 51.79862
0
16 1.5 (DL-EQZ)
949.328 62.53808
0
17 0.9DL-1.5EQZ
592.615 39.0392
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

3.27
2.6
2.89
1.72
2.64
2.93
1.77
46.02
57.16
56
40.79
51.35
52.51

1.08
21.35
26.69
27.12
23.07
28.83
28.4
0.83
1.03
0.61
0.89
1.11
0.69

65.3074
75.8567
92.2531
68.0142
71.3352
86.5812
61.4923
92.5832
113.146
88.0674
93.4786
114.998
92.2392

140
166
166
166
166
166
166
166
166
166
166
166
166

56.61
27.96
33.1
10.34
19.92
23.07
1.16
-1.12
-3.24
-25.16
10.12
10.08
-14.17

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 65.30738 kN/m2
pmax = 114.9981 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
254 5 1.5 (DL+LL)
60.95738
3.27
F3-C8 6 1.2 (DL+LL+EQX)
51.90665
2.6
0
7 1.5 (DL+EQX)
62.67312
2.89
0
8 0.9DL+1.5EQX
39.17424
1.72
0
9 1.2 (DL+LL-EQX)
45.62516
2.64
0
10 1.5 (DL-EQX)
54.82121
2.93
0
11 0.9DL-1.5EQX
31.32233
1.77
0
12 1.2 (DL+LL+EQZ)
45.7332 46.02
0
13 1.5 (DL+EQZ)
54.95626 57.16
0
14 0.9DL+1.5EQZ
31.45738
56
0
15 1.2 (DL+LL-EQZ)
51.79862 40.79
0
16 1.5 (DL-EQZ)
62.53808 51.35
0
17 0.9DL-1.5EQZ
39.0392 52.51
Joint

kN/m2

Mzz/Zzz
(3)
1.08
21.35
26.69
27.12
23.07
28.83
28.4
0.83
1.03
0.61
0.89
1.11
0.69

pmin =

1+2+3

1-2+3

-25.16 kN/m2

1-2-3

65.308 58.768
56.608
75.857 70.657
27.957
92.254 86.474
33.094
68.015 64.575
10.335
71.336 66.056
19.916
86.582 80.722
23.062
61.493 57.953
1.153
92.584
0.544
-1.117
113.147 -1.174
-3.234
88.068 -23.933 -25.153
93.479 11.899
10.119
114.999 12.299
10.079
92.24 -12.781 -14.161

1+2-3
63.148
33.157
38.874
13.775
25.196
28.922
4.693
90.924
111.09
86.848
91.699
112.78
90.86

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
254 5 1.5 (DL+LL)
1526.123 100.5351
F3-C8 6 1.2 (DL+LL+EQX)
1388.733 91.48439
0
7 1.5 (DL+EQX)
1552.168 102.2509
0
8 0.9DL+1.5EQX
1195.455 78.75198
0
9 1.2 (DL+LL-EQX)
1293.38 85.2029
0
10 1.5 (DL-EQX)
1432.976 94.39895
0
11 0.9DL-1.5EQX
1076.263 70.90007
0
12 1.2 (DL+LL+EQZ)
1295.02 85.31094
0
13 1.5 (DL+EQZ)
1435.026 94.53399
0
14 0.9DL+1.5EQZ
1078.313 71.03511
0
15 1.2 (DL+LL-EQZ)
1387.093 91.37635
0
16 1.5 (DL-EQZ)
1550.118 102.1158
0
17 0.9DL-1.5EQZ
1193.405 78.61693
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

3.27
2.6
2.89
1.72
2.64
2.93
1.77
46.02
57.16
56
40.79
51.35
52.51

1.08
21.35
26.69
27.12
23.07
28.83
28.4
0.83
1.03
0.61
0.89
1.11
0.69

104.885
115.434
131.831
107.592
110.913
126.159
101.07
132.161
152.724
127.645
133.056
154.576
131.817

140
166
166
166
166
166
166
166
166
166
166
166
166

96.19
67.54
72.68
49.92
59.5
62.64
40.74
38.47
36.35
14.43
49.7
49.66
25.42

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 104.8851 kN/m2
pmax = 154.5758 kN/m2
pmin =

96.19 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
254 5 1.5 (DL+LL)
100.5351
3.27
F3-C8 6 1.2 (DL+LL+EQX)
91.48439
2.6
0
7 1.5 (DL+EQX)
102.2509
2.89
0
8 0.9DL+1.5EQX
78.75198
1.72
0
9 1.2 (DL+LL-EQX)
85.2029
2.64
0
10 1.5 (DL-EQX)
94.39895
2.93
0
11 0.9DL-1.5EQX
70.90007
1.77
0
12 1.2 (DL+LL+EQZ)
85.31094 46.02
0
13 1.5 (DL+EQZ)
94.53399 57.16
0
14 0.9DL+1.5EQZ
71.03511
56
0
15 1.2 (DL+LL-EQZ)
91.37635 40.79
0
16 1.5 (DL-EQZ)
102.1158 51.35
0
17 0.9DL-1.5EQZ
78.61693 52.51
Joint

Mzz/Zzz
(3)
1.08
21.35
26.69
27.12
23.07
28.83
28.4
0.83
1.03
0.61
0.89
1.11
0.69

pmin =

14.43

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

104.886
115.435
131.831
107.592
110.913
126.159
101.071
132.161
152.724
127.646
133.057
154.576
131.817

98.346
110.235
126.051
104.152
105.633
120.299
97.531
40.121
38.404
15.646
51.477
51.876
26.797

96.186
67.535
72.671
49.912
59.493
62.639
40.731
38.461
36.344
14.426
49.697
49.656
25.417

102.73
72.735
78.451
53.352
64.773
68.499
44.271
130.5
150.66
126.43
131.28
152.36
130.44

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
254
F3-C8
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
39.08665 991.31
6 1.2 (DL+LL+EQX)
180.7788 991.31
7 1.5 (DL+EQX)
225.3121 991.31
8 0.9DL+1.5EQX
227.2575 991.31
9 1.2 (DL+LL-EQX)
194.9642 991.31
10 1.5 (DL-EQX)
243.0636 991.31
11 0.9DL-1.5EQX
237.9801 991.31
12 1.2 (DL+LL+EQZ)
535.5613 991.31
13 1.5 (DL+EQZ)
665.2016 991.31
14 0.9DL+1.5EQZ
651.6444 991.31
15 1.2 (DL+LL-EQZ)
474.6929 991.31
16 1.5 (DL-EQZ)
597.6157 991.31
17 0.9DL-1.5EQZ
611.0905 991.31

1526.8
1300.11
1569.78
981.2
1142.78
1373.11
784.54
1145.48
1376.49
787.92
1297.4
1566.4
977.82

64.43
12.68
11.37
8.68
10.95
9.73
7.47
3.99
3.56
2.74
4.83
4.28
3.23

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
51.46923
90.70629
110.9872
107.61
100.9681
124.1154
115.8951
130.1505
157.1845
138.9028
48.80159
66.48019
84.38889

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.342

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1526.1
1388.7
1552.2
1195.5
1293.4
1433
1076.3
1295
1435
1078.3
1387.1
1550.1
1193.4

14.83
7.66
7
5.56
6.41
5.78
4.65
4.98
4.57
3.89
14.22
11.66
7.08

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 951.378 kN
Punching Shear,P =
951.378 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 869.48 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 869480


=
1.37 x4600
= 137.97 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
154.576

kN/m2

B) One Way Shear


1400
0

1925

153.901

kN/m2

153.647

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

51.876

kN/m2
111.007 kN/m2

154.576

kN/m2

127.345

kN/m2

152.356

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 127.345 - 25 x 0.6 - 18 x ( 2 87.145 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 87.145 x 3.3 x 1.4
= 402.6099 kN
At Width
Maximum Pressure = 153.901 - 25 x 0.6 - 18 x ( 2 113.701 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 113.701 x 4.6 x 0.875
= 457.6465 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 457.64653 kN


Corresponding Length =
4600
mm
% Ast =

0.342

Allowable Shear Stress =


0.4168 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4168 x 1
2

=
0.4168 N/mm
Depth Required = 457646.53
0.4168 x 4600
=
314
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 154.576
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
114.996 kN/m2
1.925

Bending Moment = 114.996 x 1.925 x 1.925 / 2


= 213.07 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1769.46
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
177
175

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1794.29

mm

Provide 20 mm dia Bars @ 175 mm spacing bothways

i.e.0.342%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 175 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.8
4.7
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.975

Wp

1.975
Z

1.65

Lp

F4

COLUMN NO.

C9

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.65

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.8 x 4.7 x 0.6
=
267.9
kN
Buoyant Self wt. of Fdn = 0 x 3.8 x 4.7 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.8 x 4.7) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
440.622 kN
Buoyant weight of Soil = [(3.8 x 4.7) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 267.9 + 0 + 440.622


=
708.52 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
285
F4-C9

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
1.362
927.076
6 1.2 (DL+LL+EQX)
-79.957 744.403
7 1.5 (DL+EQX)
-99.941 891.845
8 0.9DL+1.5EQX
-100.487 536.478
9 1.2 (DL+LL-EQX)
82.135
738.919
10 1.5 (DL-EQX)
102.675
884.99
11 0.9DL-1.5EQX
102.128 529.623
12 1.2 (DL+LL+EQZ)
0.915
699.148
13 1.5 (DL+EQZ)
1.149
835.276
14 0.9DL+1.5EQZ
0.603
479.909
15 1.2 (DL+LL-EQZ)
1.263
784.174
16 1.5 (DL-EQZ)
1.585
941.559
17 0.9DL-1.5EQZ
1.038
586.192

kN - m)
FORCE-Z
91.731
73.563
81.884
49.219
73.207
81.439
48.774
-23.416
-39.34
-72.004
170.186
202.663
169.998

MOM-X
249.697
200.061
221.966
133.332
199.454
221.208
132.573
-329.539
-440.034
-528.669
729.055
883.208
794.573

MOM-Y
-2.118
-8.868
-10.52
-9.9
5.48
7.414
8.035
-4.926
-5.594
-4.972
1.538
2.486
3.108

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.8 x 4.7
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

17.86

m2

1/6 x 3.8 x 4.7 x 4.7


13.991

m3

1/6 x 4.7 x 3.8 x 3.8


11.312

m3

Total Vertical Load P = 927.076 + 708.52


= 1635.596 kN

MOM Z
-2.414
177.172
221.485
222.442
-181.034
-226.272
-225.315
-1.727
-2.139
-1.182
-2.135
-2.648
-1.691

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1635.596 / (3.8 x 4.7 )


=

91.579

kN/m

Mxx/Zxx = 249.697 / 13.991


Mxx/Zxx =

17.847

kN/m

Mzz/Zzz = 2.414 / 11.312


Mzz/Zzz =

0.214

kN/m

Maxi.Soil Pressure pmax = 91.579 + 17.847 + 0.214


pmax =

109.64

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 91.579 - 17.847 - 0.214
pmin =

73.52

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
249.71 kN.m
Calculation of Stabilizing Moment
Due to External Load = 927.076 x 3.8 / 2
=
1761.45 kN.m
Due to wt. of Pedestral = 0 x 1.9
=
0

kN.m

Due to Self Wt. of Fdn = 267.9 x 1.9


=
509.01 kN.m
Due to Wt. of Soil = 440.622 x 1.9
=
837.19 kN.m
Total Stabilizing moment = 1761.45 + 0 + 509.01 + 837.19
=
3107.65 kN.m
F.O.S. against Overturning = 3107.65 / 249.71
= 12.445 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

91.75

kN

Total Vertical Load = 1635.6 kN


F.O.S. against Sliding = 1635.596 x 0.5 / 91.75
=
8.92
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
285 5 1.5 (DL+LL)
927.076 51.90795
F4-C9 6 1.2 (DL+LL+EQX)
744.403 41.6799
0
7 1.5 (DL+EQX)
891.845 49.93533
0
8 0.9DL+1.5EQX
536.478 30.03796
0
9 1.2 (DL+LL-EQX)
738.919 41.37284
0
10 1.5 (DL-EQX)
884.99 49.55151
0
11 0.9DL-1.5EQX
529.623 29.65414
0
12 1.2 (DL+LL+EQZ)
699.148 39.14602
0
13 1.5 (DL+EQZ)
835.276 46.76797
0
14 0.9DL+1.5EQZ
479.909 26.8706
0
15 1.2 (DL+LL-EQZ)
784.174 43.90672
0
16 1.5 (DL-EQZ)
941.559 52.71887
0
17 0.9DL-1.5EQZ
586.192 32.8215
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

17.85
14.3
15.87
9.53
14.26
15.82
9.48
23.56
31.46
37.79
52.11
63.13
56.8

0.22
15.67
19.58
19.67
16.01
20.01
19.92
0.16
0.19
0.11
0.19
0.24
0.15

69.978
71.6499
85.3853
59.238
71.6428
85.3815
59.0541
62.866
78.418
64.7706
96.2067
116.089
89.7715

140
166
166
166
166
166
166
166
166
166
166
166
166

33.84
11.71
14.49
0.84
11.11
13.73
0.26
15.43
15.12
-11.03
-8.4
-10.66
-24.13

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 69.97795 kN/m2
pmax = 116.0889 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
285 5 1.5 (DL+LL)
51.90795 17.85
F4-C9 6 1.2 (DL+LL+EQX)
41.6799
14.3
0
7 1.5 (DL+EQX)
49.93533 15.87
0
8 0.9DL+1.5EQX
30.03796
9.53
0
9 1.2 (DL+LL-EQX)
41.37284 14.26
0
10 1.5 (DL-EQX)
49.55151 15.82
0
11 0.9DL-1.5EQX
29.65414
9.48
0
12 1.2 (DL+LL+EQZ)
39.14602 23.56
0
13 1.5 (DL+EQZ)
46.76797 31.46
0
14 0.9DL+1.5EQZ
26.8706 37.79
0
15 1.2 (DL+LL-EQZ)
43.90672 52.11
0
16 1.5 (DL-EQZ)
52.71887 63.13
0
17 0.9DL-1.5EQZ
32.8215
56.8
Joint

kN/m2

Mzz/Zzz
(3)
0.22
15.67
19.58
19.67
16.01
20.01
19.92
0.16
0.19
0.11
0.19
0.24
0.15

pmin =

1+2+3

1-2+3

-24.13 kN/m2

1-2-3

69.978 34.278
33.838
71.65
43.05
11.71
85.386 53.646
14.486
59.238 40.178
0.838
71.643 43.123
11.103
85.382 53.742
13.722
59.055 40.095
0.255
62.867 15.747
15.427
78.418 15.498
15.118
64.771 -10.81
-11.03
96.207 -8.014
-8.394
116.089 -10.172 -10.652
89.772 -23.829 -24.129

1+2-3
69.538
40.31
46.226
19.898
39.623
45.362
19.215
62.547
78.038
64.551
95.827
115.61
89.472

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
285 5 1.5 (DL+LL)
1635.596 91.57872
F4-C9 6 1.2 (DL+LL+EQX)
1452.923 81.35067
0
7 1.5 (DL+EQX)
1600.365 89.6061
0
8 0.9DL+1.5EQX
1244.998 69.70873
0
9 1.2 (DL+LL-EQX)
1447.439 81.04362
0
10 1.5 (DL-EQX)
1593.51 89.22228
0
11 0.9DL-1.5EQX
1238.143 69.32492
0
12 1.2 (DL+LL+EQZ)
1407.668 78.8168
0
13 1.5 (DL+EQZ)
1543.796 86.43875
0
14 0.9DL+1.5EQZ
1188.429 66.54138
0
15 1.2 (DL+LL-EQZ)
1492.694 83.57749
0
16 1.5 (DL-EQZ)
1650.079 92.38964
0
17 0.9DL-1.5EQZ
1294.712 72.49227
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

17.85
14.3
15.87
9.53
14.26
15.82
9.48
23.56
31.46
37.79
52.11
63.13
56.8

0.22
15.67
19.58
19.67
16.01
20.01
19.92
0.16
0.19
0.11
0.19
0.24
0.15

109.649
111.321
125.056
98.9087
111.314
125.052
98.7249
102.537
118.089
104.441
135.877
155.76
129.442

140
166
166
166
166
166
166
166
166
166
166
166
166

73.51
51.39
54.16
40.51
50.78
53.4
39.93
55.1
54.79
28.65
31.28
29.02
15.55

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 109.6487 kN/m2
pmax = 155.7596 kN/m2
pmin =

73.51 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
285 5 1.5 (DL+LL)
91.57872 17.85
F4-C9 6 1.2 (DL+LL+EQX)
81.35067
14.3
0
7 1.5 (DL+EQX)
89.6061 15.87
0
8 0.9DL+1.5EQX
69.70873
9.53
0
9 1.2 (DL+LL-EQX)
81.04362 14.26
0
10 1.5 (DL-EQX)
89.22228 15.82
0
11 0.9DL-1.5EQX
69.32492
9.48
0
12 1.2 (DL+LL+EQZ)
78.8168 23.56
0
13 1.5 (DL+EQZ)
86.43875 31.46
0
14 0.9DL+1.5EQZ
66.54138 37.79
0
15 1.2 (DL+LL-EQZ)
83.57749 52.11
0
16 1.5 (DL-EQZ)
92.38964 63.13
0
17 0.9DL-1.5EQZ
72.49227
56.8
Joint

Mzz/Zzz
(3)
0.22
15.67
19.58
19.67
16.01
20.01
19.92
0.16
0.19
0.11
0.19
0.24
0.15

pmin =

15.55

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

109.649
111.321
125.057
98.909
111.314
125.053
98.725
102.537
118.089
104.442
135.878
155.76
129.443

73.949
82.721
93.317
79.849
82.794
93.413
79.765
55.417
55.169
28.862
31.658
29.5
15.843

73.509
51.381
54.157
40.509
50.774
53.393
39.925
55.097
54.789
28.642
31.278
29.02
15.543

109.21
79.981
85.897
59.569
79.294
85.033
58.885
102.22
117.71
104.22
135.5
155.28
129.14

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
285
F4-C9
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
249.7087 1346.2
6 1.2 (DL+LL+EQX)
267.2346 1346.2
7 1.5 (DL+EQX)
313.5674 1346.2
8 0.9DL+1.5EQX
259.3412 1346.2
9 1.2 (DL+LL-EQX)
269.3607 1346.2
10 1.5 (DL-EQX)
316.4364 1346.2
11 0.9DL-1.5EQX
261.4239 1346.2
12 1.2 (DL+LL+EQZ)
329.5435 1346.2
13 1.5 (DL+EQZ)
440.0392 1346.2
14 0.9DL+1.5EQZ
528.6703 1346.2
15 1.2 (DL+LL-EQZ)
729.0581 1346.2
16 1.5 (DL-EQZ)
883.212 1346.2
17 0.9DL-1.5EQZ
794.5748 1346.2

1761.45
1414.37
1694.51
1019.31
1403.95
1681.49
1006.29
1328.39
1587.03
911.83
1489.94
1788.97
1113.77

12.45
10.34
9.7
9.13
10.21
9.57
9
8.12
6.67
4.28
3.9
3.55
3.1

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
91.74111
108.6491
129.2021
111.8935
110.0246
131.0514
113.177
23.43387
39.35678
72.00652
170.1907
202.6692
170.0012

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3800
4700
525
0.362

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1635.6
1452.9
1600.4
1245
1447.4
1593.5
1238.1
1407.7
1543.8
1188.4
1492.7
1650.1
1294.7

8.92
6.69
6.2
5.57
6.58
6.08
5.47
30.04
19.62
8.26
4.39
4.08
3.81

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 941.559 kN
Punching Shear,P =
941.559 x (( 3.8 x 4.7 ) - ( 1.025 x 1.275 ))
( 3.8 * 4.7 )
P = 872.67 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 872670


=
1.37 x4600
= 138.48 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
155.76

kN/m2

B) One Way Shear


1450
0

1975

155.612

kN/m2

155.559

kN/m2

525

600

4700

750

500
200
1650
525

1125

3800

29.5

kN/m2
100.937 kN/m2

155.76

kN/m2

118.381

kN/m2

155.28

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 118.381 - 25 x 0.6 - 18 x ( 2 78.181 kN/m2
-- For without
Length at critical section =
3800
mm
Width at critical section =
1450
mm
Shear Force = 78.181 x 3.8 x 1.45
= 430.7773 kN
At Width
Maximum Pressure = 155.612 - 25 x 0.6 - 18 x ( 2 115.412 kN/m2
-- For without
Length at critical section =
4700
mm
Width at critical section =
1125
mm
Shear Force = 115.412 x 4.7 x 1.125
= 610.241 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 610.24095 kN


Corresponding Length =
4700
mm
% Ast =

0.362

Allowable Shear Stress =


0.4272 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4272 x 1
2

=
0.4272 N/mm
Depth Required = 610240.95
0.4272 x 4700
=
379
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1650
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
472.73
Effe. Depth @ Critical s/c =
397.73
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure =
155.76
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 267.9 + 440.622 ) / ( 3.8 x 4.7 )
39.67
116.09 kN/m2
1.975

Bending Moment = 116.09 x 1.975 x 1.975 / 2


= 226.41 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1886.33
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
166
165

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1903.03

mm

Provide 20 mm dia Bars @ 165 mm spacing bothways

i.e.0.363%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 708.522 kN
Area Load = 708.522 / (3.8 x 4.7)

Maxi. Projection of fdn =

39.67

kN/m2

1.975

Bending Moment = 39.67 x 1.975 x 1.975 / 2


=
Ast =

77.37

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

622.79

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3800 mm


WIdth Of Footing :4700 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 165 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.8
4.7
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.975

Wp

1.975
Z

1.65

Lp

F4

COLUMN NO.

C10

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.65

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.8 x 4.7 x 0.6
=
267.9
kN
Buoyant Self wt. of Fdn = 0 x 3.8 x 4.7 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.8 x 4.7) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
440.622 kN
Buoyant weight of Soil = [(3.8 x 4.7) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 267.9 + 0 + 440.622


=
708.52 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
255
F4-C10

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-5.897
1042.14
6 1.2 (DL+LL+EQX)
-90.826 791.854
7 1.5 (DL+EQX)
-113.585 954.034
8 0.9DL+1.5EQX
-111.206 551.492
9 1.2 (DL+LL-EQX)
81.391
875.566
10 1.5 (DL-EQX)
101.687 1058.67
11 0.9DL-1.5EQX
104.066 656.132
12 1.2 (DL+LL+EQZ)
-4.17
756.248
13 1.5 (DL+EQZ)
-5.266
909.526
14 0.9DL+1.5EQZ
-2.886
506.984
15 1.2 (DL+LL-EQZ)
-5.264
911.172
16 1.5 (DL-EQZ)
-6.633
1103.18
17 0.9DL-1.5EQZ
-4.253
700.64

kN - m)
FORCE-Z
119.437
94.871
108.327
64.657
96.228
110.023
66.353
-22.158
-37.959
-81.629
213.256
256.309
212.639

MOM-X
222.464
175.634
193.54
114.955
180.309
199.384
120.799
-304.89
-407.114
-485.699
660.833
800.039
721.454

MOM-Y
1.648
-2.866
-3.796
-4.369
5.503
6.665
6.091
-3.411
-4.477
-5.051
6.048
7.347
6.773

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.8 x 4.7
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

17.86

m2

1/6 x 3.8 x 4.7 x 4.7


13.991

m3

1/6 x 4.7 x 3.8 x 3.8


11.312

m3

Total Vertical Load P = 1042.138 + 708.52


= 1750.658 kN

MOM Z
5.912
189.695
237.179
234.79
-180.237
-225.236
-227.625
3.996
5.055
2.667
5.462
6.888
4.499

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1750.658 / (3.8 x 4.7 )


=

98.021

kN/m

Mxx/Zxx = 222.464 / 13.991


Mxx/Zxx =

15.901

kN/m

Mzz/Zzz = 5.912 / 11.312


Mzz/Zzz =

0.523

kN/m

Maxi.Soil Pressure pmax = 98.021 + 15.901 + 0.523


pmax =

114.45

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 98.021 - 15.901 - 0.523
pmin =

81.60

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
222.55 kN.m
Calculation of Stabilizing Moment
Due to External Load = 1042.138 x 3.8 / 2
=
1980.07 kN.m
Due to wt. of Pedestral = 0 x 1.9
=
0

kN.m

Due to Self Wt. of Fdn = 267.9 x 1.9


=
509.01 kN.m
Due to Wt. of Soil = 440.622 x 1.9
=
837.19 kN.m
Total Stabilizing moment = 1980.07 + 0 + 509.01 + 837.19
=
3326.27 kN.m
F.O.S. against Overturning = 3326.27 / 222.55
= 14.9462 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force = 119.59 kN
Total Vertical Load = 1750.66 kN
F.O.S. against Sliding = 1750.658 x 0.5 / 119.59
=
7.32
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
255 5 1.5 (DL+LL)
1042.138 58.35039
F4-C10 6 1.2 (DL+LL+EQX)
791.854 44.33673
0
7 1.5 (DL+EQX)
954.034 53.41736
0
8 0.9DL+1.5EQX
551.492 30.87861
0
9 1.2 (DL+LL-EQX)
875.566 49.02385
0
10 1.5 (DL-EQX)
1058.674 59.27626
0
11 0.9DL-1.5EQX
656.132 36.73751
0
12 1.2 (DL+LL+EQZ)
756.248 42.34311
0
13 1.5 (DL+EQZ)
909.526 50.92531
0
14 0.9DL+1.5EQZ
506.984 28.38656
0
15 1.2 (DL+LL-EQZ)
911.172 51.01747
0
16 1.5 (DL-EQZ)
1103.182 61.76831
0
17 0.9DL-1.5EQZ
700.64 39.22956
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

15.91
12.56
13.84
8.22
12.89
14.26
8.64
21.8
29.1
34.72
47.24
57.19
51.57

0.53
16.77
20.97
20.76
15.94
19.92
20.13
0.36
0.45
0.24
0.49
0.61
0.4

74.7904
73.6667
88.2274
59.8586
77.8539
93.4563
65.5075
64.5031
80.4753
63.3466
98.7475
119.568
91.1996

140
166
166
166
166
166
166
166
166
166
166
166
166

41.92
15.01
18.61
1.9
20.2
25.1
7.97
20.19
21.38
-6.58
3.29
3.97
-12.75

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 74.79039 kN/m2
pmax = 119.5683 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
255 5 1.5 (DL+LL)
58.35039 15.91
F4-C10 6 1.2 (DL+LL+EQX)
44.33673 12.56
0
7 1.5 (DL+EQX)
53.41736 13.84
0
8 0.9DL+1.5EQX
30.87861
8.22
0
9 1.2 (DL+LL-EQX)
49.02385 12.89
0
10 1.5 (DL-EQX)
59.27626 14.26
0
11 0.9DL-1.5EQX
36.73751
8.64
0
12 1.2 (DL+LL+EQZ)
42.34311
21.8
0
13 1.5 (DL+EQZ)
50.92531
29.1
0
14 0.9DL+1.5EQZ
28.38656 34.72
0
15 1.2 (DL+LL-EQZ)
51.01747 47.24
0
16 1.5 (DL-EQZ)
61.76831 57.19
0
17 0.9DL-1.5EQZ
39.22956 51.57
Joint

kN/m2

Mzz/Zzz
(3)
0.53
16.77
20.97
20.76
15.94
19.92
20.13
0.36
0.45
0.24
0.49
0.61
0.4

pmin =

1+2+3

1-2+3

-12.75 kN/m2

1-2-3

74.791 42.971
41.911
73.667 48.547
15.007
88.228 60.548
18.608
59.859 43.419
1.899
77.854 52.074
20.194
93.457 64.937
25.097
65.508 48.228
7.968
64.504 20.904
20.184
80.476 22.276
21.376
63.347 -6.094
-6.574
98.748
4.268
3.288
119.569 5.189
3.969
91.2
-11.941 -12.741

1+2-3
73.731
40.127
46.288
18.339
45.974
53.617
25.248
63.784
79.576
62.867
97.768
118.35
90.4

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
255 5 1.5 (DL+LL)
1750.658 98.02116
F4-C10 6 1.2 (DL+LL+EQX)
1500.374 84.0075
0
7 1.5 (DL+EQX)
1662.554 93.08813
0
8 0.9DL+1.5EQX
1260.012 70.54938
0
9 1.2 (DL+LL-EQX)
1584.086 88.69462
0
10 1.5 (DL-EQX)
1767.194 98.94703
0
11 0.9DL-1.5EQX
1364.652 76.40829
0
12 1.2 (DL+LL+EQZ)
1464.768 82.01389
0
13 1.5 (DL+EQZ)
1618.046 90.59608
0
14 0.9DL+1.5EQZ
1215.504 68.05733
0
15 1.2 (DL+LL-EQZ)
1619.692 90.68824
0
16 1.5 (DL-EQZ)
1811.702 101.4391
0
17 0.9DL-1.5EQZ
1409.16 78.90034
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

15.91
12.56
13.84
8.22
12.89
14.26
8.64
21.8
29.1
34.72
47.24
57.19
51.57

0.53
16.77
20.97
20.76
15.94
19.92
20.13
0.36
0.45
0.24
0.49
0.61
0.4

114.461
113.338
127.898
99.5294
117.525
133.127
105.178
104.174
120.146
103.017
138.418
159.239
130.87

140
166
166
166
166
166
166
166
166
166
166
166
166

81.59
54.68
58.28
41.57
59.87
64.77
47.64
59.86
61.05
33.1
42.96
43.64
26.94

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 114.4612 kN/m2
pmax = 159.2391 kN/m2
pmin =

81.59 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
255 5 1.5 (DL+LL)
98.02116 15.91
F4-C10 6 1.2 (DL+LL+EQX)
84.0075 12.56
0
7 1.5 (DL+EQX)
93.08813 13.84
0
8 0.9DL+1.5EQX
70.54938
8.22
0
9 1.2 (DL+LL-EQX)
88.69462 12.89
0
10 1.5 (DL-EQX)
98.94703 14.26
0
11 0.9DL-1.5EQX
76.40829
8.64
0
12 1.2 (DL+LL+EQZ)
82.01389
21.8
0
13 1.5 (DL+EQZ)
90.59608
29.1
0
14 0.9DL+1.5EQZ
68.05733 34.72
0
15 1.2 (DL+LL-EQZ)
90.68824 47.24
0
16 1.5 (DL-EQZ)
101.4391 57.19
0
17 0.9DL-1.5EQZ
78.90034 51.57
Joint

Mzz/Zzz
(3)
0.53
16.77
20.97
20.76
15.94
19.92
20.13
0.36
0.45
0.24
0.49
0.61
0.4

pmin =

1+2+3

1-2+3

114.462 82.642
113.338 88.218
127.899 100.219
99.53
83.09
117.525 91.745
133.128 104.608
105.179 87.899
104.174 60.574
120.147 61.947
103.018 33.578
138.419 43.939
159.24
44.86
130.871 27.731

26.94

kN/m2

1-2-3

1+2-3

81.582
54.678
58.279
41.57
59.865
64.768
47.639
59.854
61.047
33.098
42.959
43.64
26.931

113.4
79.798
85.959
58.01
85.645
93.288
64.919
103.45
119.25
102.54
137.44
158.02
130.07

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
255
F4-C10
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
222.5425 1346.2
6 1.2 (DL+LL+EQX)
258.5179 1346.2
7 1.5 (DL+EQX)
306.1235 1346.2
8 0.9DL+1.5EQX
261.4211 1346.2
9 1.2 (DL+LL-EQX)
254.9445 1346.2
10 1.5 (DL-EQX)
300.8076 1346.2
11 0.9DL-1.5EQX
257.6927 1346.2
12 1.2 (DL+LL+EQZ)
304.9162 1346.2
13 1.5 (DL+EQZ)
407.1454 1346.2
14 0.9DL+1.5EQZ
485.7063 1346.2
15 1.2 (DL+LL-EQZ)
660.8556 1346.2
16 1.5 (DL-EQZ)
800.0687 1346.2
17 0.9DL-1.5EQZ
721.468 1346.2

1980.07
1504.53
1812.67
1047.84
1663.58
2011.49
1246.66
1436.88
1728.1
963.27
1731.23
2096.05
1331.22

14.95
11.03
10.32
9.16
11.81
11.17
10.07
9.13
7.56
4.76
4.66
4.31
3.72

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
119.5825
131.3388
156.9595
128.6363
126.033
149.8176
123.4198
22.54697
38.32253
81.68
213.321
256.3948
212.6815

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3800
4700
525
0.374

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1750.7
1500.4
1662.6
1260
1584.1
1767.2
1364.7
1464.8
1618
1215.5
1619.7
1811.7
1409.2

7.32
5.72
5.3
4.9
6.29
5.9
5.53
32.49
21.12
7.45
3.8
3.54
3.32

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 1103.182 kN
Punching Shear,P =
1103.182 x (( 3.8 x 4.7 ) - ( 1.025 x 1.275 ))
( 3.8 * 4.7 )
P = 1022.46 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 1022460


=
1.37 x4600
= 162.24 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
159.24

kN/m2

B) One Way Shear


1450
0

1975

158.864

kN/m2

158.728

kN/m2

525

600

4700

750

500
200
1650
525

1125

3800

44.86

kN/m2
109.575 kN/m2

159.24

kN/m2

125.378

kN/m2

158.02

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 125.378 - 25 x 0.6 - 18 x ( 2 85.178 kN/m2
-- For without
Length at critical section =
3800
mm
Width at critical section =
1450
mm
Shear Force = 85.178 x 3.8 x 1.45
= 469.3308 kN
At Width
Maximum Pressure = 158.864 - 25 x 0.6 - 18 x ( 2 118.664 kN/m2
-- For without
Length at critical section =
4700
mm
Width at critical section =
1125
mm
Shear Force = 118.664 x 4.7 x 1.125
= 627.4359 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 627.4359 kN


Corresponding Length =
4700
mm
% Ast =

0.374

Allowable Shear Stress =


0.4324 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4324 x 1
2
=
0.4324 N/mm
Depth Required = 627435.9
0.4324 x 4700
=
384
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm

Min. Length from column face to


edge of footing =
1650
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
472.73
Effe. Depth @ Critical s/c =
397.73
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure =
159.24
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 267.9 + 440.622 ) / ( 3.8 x 4.7 )
39.67
119.57 kN/m2
1.975

Bending Moment = 119.57 x 1.975 x 1.975 / 2


= 233.2 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1946.13
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
161
160

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1962.5

mm

Provide 20 mm dia Bars @ 160 mm spacing bothways

i.e.0.374%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 708.522 kN
Area Load = 708.522 / (3.8 x 4.7)

Maxi. Projection of fdn =

39.67

kN/m2

1.975

Bending Moment = 39.67 x 1.975 x 1.975 / 2


=
Ast =

77.37

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

622.79

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3800 mm


WIdth Of Footing :4700 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 160 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.3
4.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.925

Wp

1.925
Z

1.4

Lp

F3

COLUMN NO.

C11

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.4

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.3 x 4.6 x 0.6
=
227.7
kN
Buoyant Self wt. of Fdn = 0 x 3.3 x 4.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
373.086 kN
Buoyant weight of Soil = [(3.3 x 4.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 227.7 + 0 + 373.086


=
600.79 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
256
F3-C11

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
0.362
782.199
6 1.2 (DL+LL+EQX)
-88.691 628.007
7 1.5 (DL+EQX)
-110.75 755.308
8 0.9DL+1.5EQX
-110.941 454.309
9 1.2 (DL+LL-EQX)
89.271
623.512
10 1.5 (DL-EQX)
111.702 749.688
11 0.9DL-1.5EQX
111.512 448.689
12 1.2 (DL+LL+EQZ)
0.492
591.158
13 1.5 (DL+EQZ)
0.729
709.246
14 0.9DL+1.5EQZ
0.539
408.247
15 1.2 (DL+LL-EQZ)
0.087
660.361
16 1.5 (DL-EQZ)
0.223
795.75
17 0.9DL-1.5EQZ
0.032
494.751

kN - m)
FORCE-Z
76.938
60.307
67.006
39.582
62.794
70.115
42.69
-18.273
-31.219
-58.643
141.374
168.34
140.916

MOM-X
203.067
158.916
175.581
103.58
165.992
184.426
112.424
-274.519
-366.213
-438.215
599.427
726.22
654.219

MOM-Y
-2.343
-6.694
-8.54
-7.534
2.945
3.508
4.514
-7.705
-9.804
-8.798
3.956
4.772
5.778

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.3 x 4.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

15.18

m2

1/6 x 3.3 x 4.6 x 4.6


11.638

m3

1/6 x 4.6 x 3.3 x 3.3


8.349

m3

Total Vertical Load P = 782.199 + 600.79


= 1382.989 kN

MOM Z
-1.132
187.391
234.1
234.608
-189.202
-236.642
-236.134
-1.353
-1.83
-1.322
-0.458
-0.712
-0.203

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1382.989 / (3.3 x 4.6 )


=

91.106

kN/m

Mxx/Zxx = 203.067 / 11.638


Mxx/Zxx =

17.449

kN/m

Mzz/Zzz = 1.132 / 8.349


Mzz/Zzz =

0.136

kN/m

Maxi.Soil Pressure pmax = 91.106 + 17.449 + 0.136


pmax =

108.70

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 91.106 - 17.449 - 0.136
pmin =

73.53

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
203.08 kN.m
Calculation of Stabilizing Moment
Due to External Load = 782.199 x 3.3 / 2
=
1290.63 kN.m
Due to wt. of Pedestral = 0 x 1.65
=
0

kN.m

Due to Self Wt. of Fdn = 227.7 x 1.65


=
375.71 kN.m
Due to Wt. of Soil = 373.086 x 1.65
=
615.6
kN.m
Total Stabilizing moment = 1290.63 + 0 + 375.71 + 615.6
=
2281.94 kN.m
F.O.S. against Overturning = 2281.94 / 203.08
= 11.2367 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

76.94

kN

Total Vertical Load = 1382.99 kN


F.O.S. against Sliding = 1382.989 x 0.5 / 76.94
=
8.99
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
256 5 1.5 (DL+LL)
782.199 51.52826
F3-C11 6 1.2 (DL+LL+EQX)
628.007 41.37069
0
7 1.5 (DL+EQX)
755.308 49.75679
0
8 0.9DL+1.5EQX
454.309 29.92813
0
9 1.2 (DL+LL-EQX)
623.512 41.07457
0
10 1.5 (DL-EQX)
749.688 49.38656
0
11 0.9DL-1.5EQX
448.689 29.55791
0
12 1.2 (DL+LL+EQZ)
591.158 38.94321
0
13 1.5 (DL+EQZ)
709.246 46.7224
0
14 0.9DL+1.5EQZ
408.247 26.89374
0
15 1.2 (DL+LL-EQZ)
660.361 43.50204
0
16 1.5 (DL-EQZ)
795.75 52.42095
0
17 0.9DL-1.5EQZ
494.751 32.59229
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

17.45
13.66
15.09
8.91
14.27
15.85
9.67
23.59
31.47
37.66
51.51
62.41
56.22

0.14
22.45
28.04
28.11
22.67
28.35
28.29
0.17
0.22
0.16
0.06
0.09
0.03

69.1183
77.4807
92.8868
66.9481
78.0146
93.5866
67.5179
62.7032
78.4124
64.7137
95.072
114.921
88.8423

140
166
166
166
166
166
166
166
166
166
166
166
166

33.94
5.27
6.63
-7.1
4.14
5.19
-8.41
15.19
15.04
-10.93
-8.07
-10.08
-23.66

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 69.11826 kN/m2
pmax = 114.9209 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
256 5 1.5 (DL+LL)
51.52826 17.45
F3-C11 6 1.2 (DL+LL+EQX)
41.37069 13.66
0
7 1.5 (DL+EQX)
49.75679 15.09
0
8 0.9DL+1.5EQX
29.92813
8.91
0
9 1.2 (DL+LL-EQX)
41.07457 14.27
0
10 1.5 (DL-EQX)
49.38656 15.85
0
11 0.9DL-1.5EQX
29.55791
9.67
0
12 1.2 (DL+LL+EQZ)
38.94321 23.59
0
13 1.5 (DL+EQZ)
46.7224 31.47
0
14 0.9DL+1.5EQZ
26.89374 37.66
0
15 1.2 (DL+LL-EQZ)
43.50204 51.51
0
16 1.5 (DL-EQZ)
52.42095 62.41
0
17 0.9DL-1.5EQZ
32.59229 56.22
Joint

kN/m2

Mzz/Zzz
(3)
0.14
22.45
28.04
28.11
22.67
28.35
28.29
0.17
0.22
0.16
0.06
0.09
0.03

pmin =

1+2+3

1-2+3

-23.66 kN/m2

1-2-3

69.119 34.219
33.939
77.481 50.161
5.261
92.887 62.707
6.627
66.949 49.129
-7.092
78.015 49.475
4.135
93.587 61.887
5.187
67.518 48.178
-8.403
62.704 15.524
15.184
78.413 15.473
15.033
64.714 -10.607 -10.927
95.073 -7.948
-8.068
114.921
-9.9
-10.08
88.843 -23.598 -23.658

1+2-3
68.839
32.581
36.807
10.729
32.675
36.887
10.938
62.364
77.973
64.394
94.953
114.74
88.783

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
256 5 1.5 (DL+LL)
1382.989 91.10599
F3-C11 6 1.2 (DL+LL+EQX)
1228.797 80.94842
0
7 1.5 (DL+EQX)
1356.098 89.33452
0
8 0.9DL+1.5EQX
1055.099 69.50586
0
9 1.2 (DL+LL-EQX)
1224.302 80.65231
0
10 1.5 (DL-EQX)
1350.478 88.9643
0
11 0.9DL-1.5EQX
1049.479 69.13564
0
12 1.2 (DL+LL+EQZ)
1191.948 78.52095
0
13 1.5 (DL+EQZ)
1310.036 86.30013
0
14 0.9DL+1.5EQZ
1009.037 66.47148
0
15 1.2 (DL+LL-EQZ)
1261.151 83.07978
0
16 1.5 (DL-EQZ)
1396.54 91.99868
0
17 0.9DL-1.5EQZ
1095.541 72.17003
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

17.45
13.66
15.09
8.91
14.27
15.85
9.67
23.59
31.47
37.66
51.51
62.41
56.22

0.14
22.45
28.04
28.11
22.67
28.35
28.29
0.17
0.22
0.16
0.06
0.09
0.03

108.696
117.058
132.465
106.526
117.592
133.164
107.096
102.281
117.99
104.291
134.65
154.499
128.42

140
166
166
166
166
166
166
166
166
166
166
166
166

73.52
44.84
46.21
32.49
43.72
44.77
31.18
54.77
54.62
28.66
31.51
29.5
15.93

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 108.696 kN/m2
pmax = 154.4987 kN/m2
pmin =

73.52 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
256 5 1.5 (DL+LL)
91.10599 17.45
F3-C11 6 1.2 (DL+LL+EQX)
80.94842 13.66
0
7 1.5 (DL+EQX)
89.33452 15.09
0
8 0.9DL+1.5EQX
69.50586
8.91
0
9 1.2 (DL+LL-EQX)
80.65231 14.27
0
10 1.5 (DL-EQX)
88.9643 15.85
0
11 0.9DL-1.5EQX
69.13564
9.67
0
12 1.2 (DL+LL+EQZ)
78.52095 23.59
0
13 1.5 (DL+EQZ)
86.30013 31.47
0
14 0.9DL+1.5EQZ
66.47148 37.66
0
15 1.2 (DL+LL-EQZ)
83.07978 51.51
0
16 1.5 (DL-EQZ)
91.99868 62.41
0
17 0.9DL-1.5EQZ
72.17003 56.22
Joint

Mzz/Zzz
(3)
0.14
22.45
28.04
28.11
22.67
28.35
28.29
0.17
0.22
0.16
0.06
0.09
0.03

pmin =

1+2+3

1-2+3

108.696 73.796
117.059 89.739
132.465 102.285
106.526 88.706
117.593 89.053
133.165 101.465
107.096 87.756
102.281 55.101
117.991 55.051
104.292 28.972
134.65
31.63
154.499 29.679
128.421 15.981

15.93

kN/m2

1-2-3

1+2-3

73.516
44.839
46.205
32.486
43.713
44.765
31.176
54.761
54.611
28.652
31.51
29.499
15.921

108.42
72.159
76.385
50.306
72.253
76.465
50.516
101.94
117.55
103.97
134.53
154.32
128.36

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
256
F3-C11
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
203.0702 991.31
6 1.2 (DL+LL+EQX)
245.7024 991.31
7 1.5 (DL+EQX)
292.6286 991.31
8 0.9DL+1.5EQX
256.4561 991.31
9 1.2 (DL+LL-EQX)
251.6957 991.31
10 1.5 (DL-EQX)
300.0206 991.31
11 0.9DL-1.5EQX
261.5309 991.31
12 1.2 (DL+LL+EQZ)
274.5223 991.31
13 1.5 (DL+EQZ)
366.2176 991.31
14 0.9DL+1.5EQZ
438.217 991.31
15 1.2 (DL+LL-EQZ)
599.4272 991.31
16 1.5 (DL-EQZ)
726.2203 991.31
17 0.9DL-1.5EQZ
654.219 991.31

1290.63
1036.22
1246.26
749.61
1028.8
1236.99
740.34
975.42
1170.26
673.61
1089.6
1312.99
816.34

11.24
8.26
7.65
6.79
8.03
7.43
6.63
7.17
5.91
3.8
3.48
3.18
2.77

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
76.93885
107.2522
129.4425
117.7907
109.1439
131.8842
119.4042
18.27962
31.22751
58.64548
141.374
168.3401
140.916

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3300
4600
525
0.342

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1383
1228.8
1356.1
1055.1
1224.3
1350.5
1049.5
1191.9
1310
1009
1261.2
1396.5
1095.5

8.99
5.73
5.24
4.48
5.61
5.12
4.4
32.61
20.98
8.61
4.47
4.15
3.89

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column =
795.75 kN
Punching Shear,P =
795.75 x (( 3.3 x 4.6 ) - ( 1.025 x 1.275 ))
( 3.3 * 4.6 )
P = 727.25 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 727250


=
1.37 x4600
= 115.4 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
154.499

kN/m2

B) One Way Shear


1400
0

1925

154.445

kN/m2

154.424

kN/m2

525

600

4600

750

500
200
1400
525

875

3300

29.679

kN/m2
101.546 kN/m2

154.499

kN/m2

121.403

kN/m2

154.319

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 121.403 - 25 x 0.6 - 18 x ( 2 81.203 kN/m2
-- For without
Length at critical section =
3300
mm
Width at critical section =
1400
mm
Shear Force = 81.203 x 3.3 x 1.4
= 375.1579 kN
At Width
Maximum Pressure = 154.445 - 25 x 0.6 - 18 x ( 2 114.245 kN/m2
-- For without
Length at critical section =
4600
mm
Width at critical section =
875
mm
Shear Force = 114.245 x 4.6 x 0.875
= 459.8361 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 459.83613 kN


Corresponding Length =
4600
mm
% Ast =

0.342

Allowable Shear Stress =


0.4168 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4168 x 1
2

=
0.4168 N/mm
Depth Required = 459836.13
0.4168 x 4600
=
315
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1400
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
450
Effe. Depth @ Critical s/c =
375
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 154.499
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 227.7 + 373.086 ) / ( 3.3 x 4.6 )
39.58
114.919 kN/m2
1.925

Bending Moment = 114.919 x 1.925 x 1.925 / 2


= 212.92 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =

1768.15
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
177
175

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1794.29

mm

Provide 20 mm dia Bars @ 175 mm spacing bothways

i.e.0.342%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 600.786 kN
Area Load = 600.786 / (3.3 x 4.6)

Maxi. Projection of fdn =

39.58

kN/m2

1.925

Bending Moment = 39.58 x 1.925 x 1.925 / 2


=
Ast =

73.33

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

589.75

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3300 mm


WIdth Of Footing :4600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 175 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3
4.2
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.725

Wp

1.725
Z

1.25

Lp

F5

COLUMN NO.

C12

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.25

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3 x 4.2 x 0.6
=
189
kN
Buoyant Self wt. of Fdn = 0 x 3 x 4.2 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3 x 4.2) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
308.07 kN
Buoyant weight of Soil = [(3 x 4.2) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 189 + 0 + 308.07


=
497.07 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
257
F5-C12

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-1.034
703.314
6 1.2 (DL+LL+EQX)
-91.688 524.238
7 1.5 (DL+EQX)
-114.621 632.568
8 0.9DL+1.5EQX
-114.203 360.334
9 1.2 (DL+LL-EQX)
90.033
601.065
10 1.5 (DL-EQX)
112.531 728.602
11 0.9DL-1.5EQX
112.949 456.368
12 1.2 (DL+LL+EQZ)
-0.837
532.101
13 1.5 (DL+EQZ)
-1.057
642.397
14 0.9DL+1.5EQZ
-0.639
370.163
15 1.2 (DL+LL-EQZ)
-0.818
593.202
16 1.5 (DL-EQZ)
-1.034
718.773
17 0.9DL-1.5EQZ
-0.615
446.539

kN - m)
FORCE-Z
51.878
36.249
39.895
21.311
46.756
53.028
34.444
-23.21
-34.428
-53.013
106.214
127.352
108.767

MOM-X
141.846
99.432
109.077
58.424
127.523
144.191
93.538
-237.786
-312.445
-363.099
464.741
565.714
515.06

MOM-Y
8.031
2.317
2.015
-0.845
10.533
12.285
9.425
-12.63
-16.67
-19.53
25.48
30.969
28.109

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3 x 4.2
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

12.6

m2

1/6 x 3 x 4.2 x 4.2


8.82

m3

1/6 x 4.2 x 3 x 3
6.3

m3

Total Vertical Load P = 703.314 + 497.07


= 1200.384 kN

MOM Z
0.537
190.966
238.693
238.484
-190.107
-237.649
-237.858
0.13
0.147
-0.062
0.729
0.897
0.688

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1200.384 / (3 x 4.2 )


=

95.269

kN/m

Mxx/Zxx = 141.846 / 8.82


Mxx/Zxx =

16.083

kN/m

Mzz/Zzz = 0.537 / 6.3


Mzz/Zzz =

0.086

kN/m

Maxi.Soil Pressure pmax = 95.269 + 16.083 + 0.086


pmax =

111.44

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 95.269 - 16.083 - 0.086
pmin =

79.10

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
141.85 kN.m
Calculation of Stabilizing Moment
Due to External Load = 703.314 x 3 / 2
=
1054.98 kN.m
Due to wt. of Pedestral = 0 x 1.5
=
0

kN.m

Due to Self Wt. of Fdn = 189 x 1.5


=
283.5
kN.m
Due to Wt. of Soil = 308.07 x 1.5
=
462.11 kN.m
Total Stabilizing moment = 1054.98 + 0 + 283.5 + 462.11
=
1800.59 kN.m
F.O.S. against Overturning = 1800.59 / 141.85
= 12.6936 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

51.89

kN

Total Vertical Load = 1200.38 kN


F.O.S. against Sliding = 1200.384 x 0.5 / 51.89
= 11.57
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
257 5 1.5 (DL+LL)
703.314 55.81857
F5-C12 6 1.2 (DL+LL+EQX)
524.238 41.60619
0
7 1.5 (DL+EQX)
632.568 50.20381
0
8 0.9DL+1.5EQX
360.334 28.59794
0
9 1.2 (DL+LL-EQX)
601.065 47.70357
0
10 1.5 (DL-EQX)
728.602 57.82556
0
11 0.9DL-1.5EQX
456.368 36.21968
0
12 1.2 (DL+LL+EQZ)
532.101 42.23024
0
13 1.5 (DL+EQZ)
642.397 50.98389
0
14 0.9DL+1.5EQZ
370.163 29.37802
0
15 1.2 (DL+LL-EQZ)
593.202 47.07952
0
16 1.5 (DL-EQZ)
718.773 57.04548
0
17 0.9DL-1.5EQZ
446.539 35.4396
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

16.09
11.28
12.37
6.63
14.46
16.35
10.61
26.96
35.43
41.17
52.7
64.14
58.4

0.09
30.32
37.89
37.86
30.18
37.73
37.76
0.03
0.03
0.01
0.12
0.15
0.11

71.9986
83.2062
100.464
73.0879
92.3436
111.906
84.5897
69.2202
86.4439
70.558
99.8995
121.335
93.9496

140
166
166
166
166
166
166
166
166
166
166
166
166

39.64
0.01
-0.06
-15.9
3.07
3.75
-12.16
15.25
15.53
-11.81
-5.75
-7.25
-23.08

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 71.99857 kN/m2
pmax = 121.3355 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
257 5 1.5 (DL+LL)
55.81857 16.09
F5-C12 6 1.2 (DL+LL+EQX)
41.60619 11.28
0
7 1.5 (DL+EQX)
50.20381 12.37
0
8 0.9DL+1.5EQX
28.59794
6.63
0
9 1.2 (DL+LL-EQX)
47.70357 14.46
0
10 1.5 (DL-EQX)
57.82556 16.35
0
11 0.9DL-1.5EQX
36.21968 10.61
0
12 1.2 (DL+LL+EQZ)
42.23024 26.96
0
13 1.5 (DL+EQZ)
50.98389 35.43
0
14 0.9DL+1.5EQZ
29.37802 41.17
0
15 1.2 (DL+LL-EQZ)
47.07952
52.7
0
16 1.5 (DL-EQZ)
57.04548 64.14
0
17 0.9DL-1.5EQZ
35.4396
58.4
Joint

kN/m2

Mzz/Zzz
(3)
0.09
30.32
37.89
37.86
30.18
37.73
37.76
0.03
0.03
0.01
0.12
0.15
0.11

pmin =

1+2+3

1-2+3

-23.08 kN/m2

1-2-3

71.999 39.819
39.639
83.207 60.647
0.007
100.464 75.724
-0.057
73.088 59.828 -15.893
92.344 63.424
3.064
111.906 79.206
3.746
84.59
63.37
-12.151
69.221 15.301
15.241
86.444 15.584
15.524
70.559 -11.782 -11.802
99.9
-5.501
-5.741
121.336 -6.945
-7.245
93.95 -22.851 -23.071

1+2-3
71.819
22.567
24.684
-2.633
31.984
36.446
9.07
69.161
86.384
70.539
99.66
121.04
93.73

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
257 5 1.5 (DL+LL)
1200.384 95.26857
F5-C12 6 1.2 (DL+LL+EQX)
1021.308 81.05619
0
7 1.5 (DL+EQX)
1129.638 89.65381
0
8 0.9DL+1.5EQX
857.404 68.04794
0
9 1.2 (DL+LL-EQX)
1098.135 87.15357
0
10 1.5 (DL-EQX)
1225.672 97.27556
0
11 0.9DL-1.5EQX
953.438 75.66968
0
12 1.2 (DL+LL+EQZ)
1029.171 81.68024
0
13 1.5 (DL+EQZ)
1139.467 90.43389
0
14 0.9DL+1.5EQZ
867.233 68.82802
0
15 1.2 (DL+LL-EQZ)
1090.272 86.52952
0
16 1.5 (DL-EQZ)
1215.843 96.49548
0
17 0.9DL-1.5EQZ
943.609 74.8896
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

16.09
11.28
12.37
6.63
14.46
16.35
10.61
26.96
35.43
41.17
52.7
64.14
58.4

0.09
30.32
37.89
37.86
30.18
37.73
37.76
0.03
0.03
0.01
0.12
0.15
0.11

111.449
122.656
139.914
112.538
131.794
151.356
124.04
108.67
125.894
110.008
139.35
160.785
133.4

140
166
166
166
166
166
166
166
166
166
166
166
166

79.09
39.46
39.4
23.56
42.52
43.2
27.3
54.7
54.98
27.65
33.71
32.21
16.38

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 111.4486 kN/m2
pmax = 160.7855 kN/m2
pmin =

79.09 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
257 5 1.5 (DL+LL)
95.26857 16.09
F5-C12 6 1.2 (DL+LL+EQX)
81.05619 11.28
0
7 1.5 (DL+EQX)
89.65381 12.37
0
8 0.9DL+1.5EQX
68.04794
6.63
0
9 1.2 (DL+LL-EQX)
87.15357 14.46
0
10 1.5 (DL-EQX)
97.27556 16.35
0
11 0.9DL-1.5EQX
75.66968 10.61
0
12 1.2 (DL+LL+EQZ)
81.68024 26.96
0
13 1.5 (DL+EQZ)
90.43389 35.43
0
14 0.9DL+1.5EQZ
68.82802 41.17
0
15 1.2 (DL+LL-EQZ)
86.52952
52.7
0
16 1.5 (DL-EQZ)
96.49548 64.14
0
17 0.9DL-1.5EQZ
74.8896
58.4
Joint

Mzz/Zzz
(3)
0.09
30.32
37.89
37.86
30.18
37.73
37.76
0.03
0.03
0.01
0.12
0.15
0.11

pmin =

16.38

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

111.449
122.657
139.914
112.538
131.794
151.356
124.04
108.671
125.894
110.009
139.35
160.786
133.4

79.269
100.097
115.174
99.278
102.874
118.656
102.82
54.751
55.034
27.669
33.95
32.506
16.6

79.089
39.457
39.394
23.558
42.514
43.196
27.3
54.691
54.974
27.649
33.71
32.206
16.38

111.27
62.017
64.134
36.818
71.434
75.896
48.52
108.61
125.83
109.99
139.11
160.49
133.18

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
257
F5-C12
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
141.847 745.61
6 1.2 (DL+LL+EQX)
215.3015 745.61
7 1.5 (DL+EQX)
262.435 745.61
8 0.9DL+1.5EQX
245.5361 745.61
9 1.2 (DL+LL-EQX)
228.9166 745.61
10 1.5 (DL-EQX)
277.9714 745.61
11 0.9DL-1.5EQX
255.5891 745.61
12 1.2 (DL+LL+EQZ)
237.786 745.61
13 1.5 (DL+EQZ)
312.445 745.61
14 0.9DL+1.5EQZ
363.099 745.61
15 1.2 (DL+LL-EQZ)
464.7416 745.61
16 1.5 (DL-EQZ)
565.7147 745.61
17 0.9DL-1.5EQZ
515.0605 745.61

1054.98
786.36
948.86
540.51
901.6
1092.91
684.56
798.16
963.6
555.25
889.81
1078.16
669.81

12.7
7.12
6.46
5.24
7.2
6.62
5.6
6.5
5.48
3.59
3.52
3.23
2.75

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
51.8883
98.59351
121.3655
116.1744
101.4498
124.3993
118.0841
23.22509
34.44422
53.01685
106.2171
127.3562
108.7687

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3000
4200
525
0.284

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1200.4
1021.3
1129.6
857.4
1098.1
1225.7
953.44
1029.2
1139.5
867.23
1090.3
1215.8
943.61

11.57
5.18
4.66
3.7
5.42
4.93
4.04
22.16
16.55
8.18
5.14
4.78
4.34

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 728.602 kN
Punching Shear,P =
728.602 x (( 3 x 4.2 ) - ( 1.025 x 1.275 ))
( 3 * 4.2 )
P = 653.04 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 653040


=
1.37 x4600
= 103.62 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
160.786

kN/m2

B) One Way Shear


1200
0

1725

160.701

kN/m2

160.663

kN/m2

525

600

4200

750

500
200
1250
525

725

3000

32.506

kN/m2
107.336 kN/m2

160.786

kN/m2

129.785

kN/m2

160.486

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 129.785 - 25 x 0.6 - 18 x ( 2 89.585 kN/m2
-- For without
Length at critical section =
3000
mm
Width at critical section =
1200
mm
Shear Force = 89.585 x 3 x 1.2
= 322.506 kN
At Width
Maximum Pressure = 160.701 - 25 x 0.6 - 18 x ( 2 120.501 kN/m2
-- For without
Length at critical section =
4200
mm
Width at critical section =
725
mm
Shear Force = 120.501 x 4.2 x 0.725
= 366.9255 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 366.92555 kN


Corresponding Length =
4200
mm
% Ast =

0.284

Allowable Shear Stress =


0.3856 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.3856 x 1
2

=
0.3856 N/mm
Depth Required = 366925.55
0.3856 x 4200
=
302
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1250
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
432
Effe. Depth @ Critical s/c =
357
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 160.786
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 189 + 308.07 ) / ( 3 x 4.2 )
39.45
121.336 kN/m2
1.725

Bending Moment = 121.336 x 1.725 x 1.725 / 2


= 180.53 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

1487.64
0.2
1050
16
200.96
135
135

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1488.59

mm

Provide 16 mm dia Bars @ 135 mm spacing bothways

i.e.0.284%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
497.07 kN
Area Load = 497.07 / (3 x 4.2)

Maxi. Projection of fdn =

39.45

kN/m2

1.725

Bending Moment = 39.45 x 1.725 x 1.725 / 2


=
Ast =

58.69

kN.m

0.5 x fck x b x d

1 -

fy
470.5

mm2

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Ast =

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3000 mm


WIdth Of Footing :4200 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 135 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3
4.2
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.725

Wp

1.725
Z

1.25

Lp

F5

COLUMN NO.

C13

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.25

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3 x 4.2 x 0.6
=
189
kN
Buoyant Self wt. of Fdn = 0 x 3 x 4.2 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3 x 4.2) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
308.07 kN
Buoyant weight of Soil = [(3 x 4.2) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 189 + 0 + 308.07


=
497.07 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
258
F5-C13

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
7.004
778.523
6 1.2 (DL+LL+EQX)
-82.068 668.481
7 1.5 (DL+EQX)
-102.337 819.79
8 0.9DL+1.5EQX
-105.238 514.705
9 1.2 (DL+LL-EQX)
93.275
577.156
10 1.5 (DL-EQX)
116.84
705.634
11 0.9DL-1.5EQX
113.94
400.549
12 1.2 (DL+LL+EQZ)
5.787
515.961
13 1.5 (DL+EQZ)
7.481
629.14
14 0.9DL+1.5EQZ
4.58
324.055
15 1.2 (DL+LL-EQZ)
5.42
729.676
16 1.5 (DL-EQZ)
7.022
896.284
17 0.9DL-1.5EQZ
4.121
591.199

kN - m)
FORCE-Z
14.288
11.726
15.359
9.363
11.135
14.62
8.624
-69.685
-86.405
-92.4
92.546
116.383
110.388

MOM-X
12.94
11.139
14.395
9.03
9.565
12.427
7.063
-252.735
-315.448
-320.813
273.44
342.27
336.906

MOM-Y
4.239
-7.347
-9.629
-11.15
14.13
17.216
15.699
-12.29
-15.81
-17.33
19.077
23.401
21.883

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3 x 4.2
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

12.6

m2

1/6 x 3 x 4.2 x 4.2


8.82

m3

1/6 x 4.2 x 3 x 3
6.3

m3

Total Vertical Load P = 778.523 + 497.07


= 1275.593 kN

MOM Z
-8.563
180.207
224.945
228.496
-193.908
-242.699
-239.148
-7.443
-9.618
-6.067
-6.258
-8.137
-4.586

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1275.593 / (3 x 4.2 )


=

101.238

kN/m

Mxx/Zxx = 12.94 / 8.82


Mxx/Zxx =

1.468

kN/m

Mzz/Zzz = 8.563 / 6.3


Mzz/Zzz =

1.360

kN/m

Maxi.Soil Pressure pmax = 101.238 + 1.468 + 1.36


pmax =

104.07

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 101.238 - 1.468 - 1.36
pmin =

98.41

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
15.52
kN.m
Calculation of Stabilizing Moment
Due to External Load = 778.523 x 3 / 2
=
1167.79 kN.m
Due to wt. of Pedestral = 0 x 1.5
=
0

kN.m

Due to Self Wt. of Fdn = 189 x 1.5


=
283.5
kN.m
Due to Wt. of Soil = 308.07 x 1.5
=
462.11 kN.m
Total Stabilizing moment = 1167.79 + 0 + 283.5 + 462.11
=
1913.4 kN.m
F.O.S. against Overturning = 1913.4 / 15.52
= 123.286 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

15.92

kN

Total Vertical Load = 1275.59 kN


F.O.S. against Sliding = 1275.593 x 0.5 / 15.92
= 40.07
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
258 5 1.5 (DL+LL)
778.523 61.78754
F5-C13 6 1.2 (DL+LL+EQX)
668.481 53.05405
0
7 1.5 (DL+EQX)
819.79 65.0627
0
8 0.9DL+1.5EQX
514.705 40.8496
0
9 1.2 (DL+LL-EQX)
577.156 45.80603
0
10 1.5 (DL-EQX)
705.634 56.0027
0
11 0.9DL-1.5EQX
400.549 31.7896
0
12 1.2 (DL+LL+EQZ)
515.961 40.94929
0
13 1.5 (DL+EQZ)
629.14 49.93175
0
14 0.9DL+1.5EQZ
324.055 25.71865
0
15 1.2 (DL+LL-EQZ)
729.676 57.91079
0
16 1.5 (DL-EQZ)
896.284 71.13365
0
17 0.9DL-1.5EQZ
591.199 46.92056
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

1.47
1.27
1.64
1.03
1.09
1.41
0.81
28.66
35.77
36.38
31.01
38.81
38.2

1.36
28.61
35.71
36.27
30.78
38.53
37.96
1.19
1.53
0.97
1
1.3
0.73

64.6175
82.934
102.413
78.1496
77.676
95.9427
70.5596
70.7993
87.2317
63.0687
89.9208
111.244
85.8506

140
166
166
166
166
166
166
166
166
166
166
166
166

58.96
23.18
27.72
3.55
13.94
16.07
-6.99
11.1
12.64
-11.64
25.91
31.03
8

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 64.61754 kN/m2
pmax = 111.2437 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
258 5 1.5 (DL+LL)
61.78754
1.47
F5-C13 6 1.2 (DL+LL+EQX)
53.05405
1.27
0
7 1.5 (DL+EQX)
65.0627
1.64
0
8 0.9DL+1.5EQX
40.8496
1.03
0
9 1.2 (DL+LL-EQX)
45.80603
1.09
0
10 1.5 (DL-EQX)
56.0027
1.41
0
11 0.9DL-1.5EQX
31.7896
0.81
0
12 1.2 (DL+LL+EQZ)
40.94929 28.66
0
13 1.5 (DL+EQZ)
49.93175 35.77
0
14 0.9DL+1.5EQZ
25.71865 36.38
0
15 1.2 (DL+LL-EQZ)
57.91079 31.01
0
16 1.5 (DL-EQZ)
71.13365 38.81
0
17 0.9DL-1.5EQZ
46.92056
38.2
Joint

kN/m2

Mzz/Zzz
(3)
1.36
28.61
35.71
36.27
30.78
38.53
37.96
1.19
1.53
0.97
1
1.3
0.73

pmin =

-11.64 kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

64.618
82.935
102.413
78.15
77.677
95.943
70.56
70.8
87.232
63.069
89.921
111.244
85.851

61.678
80.395
99.133
76.09
75.497
93.123
68.94
13.48
15.692
-9.692
27.901
33.624
9.451

58.958
23.175
27.713
3.55
13.937
16.063
-6.981
11.1
12.632
-11.632
25.901
31.024
7.991

61.898
25.715
30.993
5.61
16.117
18.883
-5.361
68.42
84.172
61.129
87.921
108.64
84.391

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
258 5 1.5 (DL+LL)
1275.593 101.2375
F5-C13 6 1.2 (DL+LL+EQX)
1165.551 92.50405
0
7 1.5 (DL+EQX)
1316.86 104.5127
0
8 0.9DL+1.5EQX
1011.775 80.2996
0
9 1.2 (DL+LL-EQX)
1074.226 85.25603
0
10 1.5 (DL-EQX)
1202.704 95.4527
0
11 0.9DL-1.5EQX
897.619 71.2396
0
12 1.2 (DL+LL+EQZ)
1013.031 80.39929
0
13 1.5 (DL+EQZ)
1126.21 89.38175
0
14 0.9DL+1.5EQZ
821.125 65.16865
0
15 1.2 (DL+LL-EQZ)
1226.746 97.36079
0
16 1.5 (DL-EQZ)
1393.354 110.5837
0
17 0.9DL-1.5EQZ
1088.269 86.37056
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

1.47
1.27
1.64
1.03
1.09
1.41
0.81
28.66
35.77
36.38
31.01
38.81
38.2

1.36
28.61
35.71
36.27
30.78
38.53
37.96
1.19
1.53
0.97
1
1.3
0.73

104.068
122.384
141.863
117.6
117.126
135.393
110.01
110.249
126.682
102.519
129.371
150.694
125.301

140
166
166
166
166
166
166
166
166
166
166
166
166

98.41
62.63
67.17
43
53.39
55.52
32.47
50.55
52.09
27.82
65.36
70.48
47.45

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 104.0675 kN/m2
pmax = 150.6937 kN/m2
pmin =

98.41 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
258 5 1.5 (DL+LL)
101.2375
1.47
F5-C13 6 1.2 (DL+LL+EQX)
92.50405
1.27
0
7 1.5 (DL+EQX)
104.5127
1.64
0
8 0.9DL+1.5EQX
80.2996
1.03
0
9 1.2 (DL+LL-EQX)
85.25603
1.09
0
10 1.5 (DL-EQX)
95.4527
1.41
0
11 0.9DL-1.5EQX
71.2396
0.81
0
12 1.2 (DL+LL+EQZ)
80.39929 28.66
0
13 1.5 (DL+EQZ)
89.38175 35.77
0
14 0.9DL+1.5EQZ
65.16865 36.38
0
15 1.2 (DL+LL-EQZ)
97.36079 31.01
0
16 1.5 (DL-EQZ)
110.5837 38.81
0
17 0.9DL-1.5EQZ
86.37056
38.2
Joint

Mzz/Zzz
(3)
1.36
28.61
35.71
36.27
30.78
38.53
37.96
1.19
1.53
0.97
1
1.3
0.73

pmin =

27.82

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

104.068
122.385
141.863
117.6
117.127
135.393
110.01
110.25
126.682
102.519
129.371
150.694
125.301

101.128
119.845
138.583
115.54
114.947
132.573
108.39
52.93
55.142
29.759
67.351
73.074
48.901

98.408
62.625
67.163
43
53.387
55.513
32.47
50.55
52.082
27.819
65.351
70.474
47.441

101.35
65.165
70.443
45.06
55.567
58.333
34.09
107.87
123.62
100.58
127.37
148.09
123.84

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
258
F5-C13
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
15.51672 745.61
6 1.2 (DL+LL+EQX)
180.5509 745.61
7 1.5 (DL+EQX)
225.4051 745.61
8 0.9DL+1.5EQX
228.6744 745.61
9 1.2 (DL+LL-EQX)
194.1438 745.61
10 1.5 (DL-EQX)
243.0169 745.61
11 0.9DL-1.5EQX
239.2523 745.61
12 1.2 (DL+LL+EQZ)
252.8446 745.61
13 1.5 (DL+EQZ)
315.5946 745.61
14 0.9DL+1.5EQZ
320.8704 745.61
15 1.2 (DL+LL-EQZ)
273.5116 745.61
16 1.5 (DL-EQZ)
342.3667 745.61
17 0.9DL-1.5EQZ
336.9372 745.61

1167.79
1002.73
1229.69
772.06
865.74
1058.46
600.83
773.95
943.71
486.09
1094.52
1344.43
886.8

123.32
9.69
8.77
6.64
8.3
7.43
5.63
6.01
5.36
3.84
6.73
6.11
4.85

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
15.91235
82.90148
103.4831
105.6537
93.93729
117.7511
114.2659
69.92488
86.72825
92.51344
92.70458
116.5946
110.4649

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3000
4200
525
0.264

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1275.6
1165.6
1316.9
1011.8
1074.2
1202.7
897.62
1013
1126.2
821.13
1226.7
1393.4
1088.3

40.09
7.03
6.37
4.79
5.72
5.11
3.93
7.25
6.5
4.44
6.62
5.98
4.93

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 896.284 kN
Punching Shear,P =
896.284 x (( 3 x 4.2 ) - ( 1.025 x 1.275 ))
( 3 * 4.2 )
P = 803.33 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 803330


=
1.37 x4600
= 127.47 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
150.694

kN/m2

B) One Way Shear


1200
0

1725

149.952

kN/m2

149.627

kN/m2

525

600

4200

750

500
200
1250
525

725

3000

73.074

kN/m2
118.353 kN/m2

150.694

kN/m2

131.936

kN/m2

148.094

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 131.936 - 25 x 0.6 - 18 x ( 2 91.736 kN/m2
-- For without
Length at critical section =
3000
mm
Width at critical section =
1200
mm
Shear Force = 91.736 x 3 x 1.2
= 330.2496 kN
At Width
Maximum Pressure = 149.952 - 25 x 0.6 - 18 x ( 2 109.752 kN/m2
-- For without
Length at critical section =
4200
mm
Width at critical section =
725
mm
Shear Force = 109.752 x 4.2 x 0.725
= 334.1948 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 334.19484 kN


Corresponding Length =
4200
mm
% Ast =

0.264

Allowable Shear Stress =


0.3752 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.3752 x 1
2

=
0.3752 N/mm
Depth Required = 334194.84
0.3752 x 4200
=
288
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1250
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
432
Effe. Depth @ Critical s/c =
357
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 150.694
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 189 + 308.07 ) / ( 3 x 4.2 )
39.45
111.244 kN/m2
1.725

Bending Moment = 111.244 x 1.725 x 1.725 / 2


= 165.51 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

1359.08
0.2
1050
16
200.96
147
145

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1385.93

mm

Provide 16 mm dia Bars @ 145 mm spacing bothways

i.e.0.264%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
497.07 kN
Area Load = 497.07 / (3 x 4.2)

Maxi. Projection of fdn =

39.45

kN/m2

1.725

Bending Moment = 39.45 x 1.725 x 1.725 / 2


=
Ast =

58.69

kN.m

0.5 x fck x b x d

1 -

fy
470.5

mm2

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Ast =

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3000 mm


WIdth Of Footing :4200 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 145 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3.1
3.1
0.5
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.175

Wp

1.175
Z

1.3

Lp

F6

COLUMN NO.

C14

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.3

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3.1 x 3.1 x 0.5
=
120.13 kN
Buoyant Self wt. of Fdn = 0 x 3.1 x 3.1 x 0.5
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3.1 x 3.1) - (0.5 x 0.75)] x (2 - 0.5 ) x 18


=
249.345 kN
Buoyant weight of Soil = [(3.1 x 3.1) - (0.5 x 0.75)] x (2 - 0.5 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 120.13 + 0 + 249.345


=
369.48 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
259
F6-C14

INPUT:- INPUT STAAD SUPPORT REACTION (Unit kN - m)


LOAD
FORCE-X FORCE-Y FORCE-Z
MOM-X
MOM-Y
5 1.5 (DL+LL)
-15.427 548.914 32.236
33.25
-0.382
6 1.2 (DL+LL+EQX)
-71.797 543.253 25.138
25.866 -15.73
7 1.5 (DL+EQX)
-89.908
668.07 32.084
32.774 -19.64
8 0.9DL+1.5EQX
-83.672 452.903 18.925
19.297 -19.49
9 1.2 (DL+LL-EQX)
47.113
335.009 26.439
27.334 15.121
10 1.5 (DL-EQX)
58.73
407.765 33.711
34.609
18.93
11 0.9DL-1.5EQX
64.966
192.598 20.552
21.133 19.071
12 1.2 (DL+LL+EQZ)
-12.052 404.984 -10.226 -98.767 -7.175
13 1.5 (DL+EQZ)
-15.227 495.234 -12.121 -123.017 -8.94
14 0.9DL+1.5EQZ
-8.991
280.067 -25.28 -136.494 -8.799
15 1.2 (DL+LL-EQZ)
-12.631 473.278 61.804 151.967 6.564
16 1.5 (DL-EQZ)
-15.951 580.601 77.916
190.4
8.235
17 0.9DL-1.5EQZ
-9.715
365.434 64.757 176.923 8.376

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3.1 x 3.1
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

9.61

m2

1/6 x 3.1 x 3.1 x 3.1


4.966

m3

1/6 x 3.1 x 3.1 x 3.1


4.966

m3

Total Vertical Load P = 548.914 + 369.48


= 918.394 kN

MOM Z
16.952
168.566
210.826
203.998
-141.443
-176.685
-183.513
12.823
16.147
9.319
14.3
17.993
11.165

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 918.394 / (3.1 x 3.1 )


=

95.566

kN/m

Mxx/Zxx = 33.25 / 4.966


Mxx/Zxx =

6.696

kN/m

Mzz/Zzz = 16.952 / 4.966


Mzz/Zzz =

3.414

kN/m

Maxi.Soil Pressure pmax = 95.566 + 6.696 + 3.414


pmax =

105.68

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 95.566 - 6.696 - 3.414
pmin =

85.46

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
37.33
kN.m
Calculation of Stabilizing Moment
Due to External Load = 548.914 x 3.1 / 2
=
850.82 kN.m
Due to wt. of Pedestral = 0 x 1.55
=
0

kN.m

Due to Self Wt. of Fdn = 120.13 x 1.55


=
186.2
kN.m
Due to Wt. of Soil = 249.345 x 1.55
=
386.49 kN.m
Total Stabilizing moment = 850.82 + 0 + 186.2 + 386.49
=
1423.51 kN.m
F.O.S. against Overturning = 1423.51 / 37.33
= 38.1331 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

35.74

kN

Total Vertical Load = 918.394 kN


F.O.S. against Sliding = 918.394 x 0.5 / 35.74
= 12.85
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
259 5 1.5 (DL+LL)
548.914 57.11904
F6-C14 6 1.2 (DL+LL+EQX)
543.253 56.52997
0
7 1.5 (DL+EQX)
668.07 69.51821
0
8 0.9DL+1.5EQX
452.903 47.1283
0
9 1.2 (DL+LL-EQX)
335.009 34.86046
0
10 1.5 (DL-EQX)
407.765 42.43132
0
11 0.9DL-1.5EQX
192.598 20.04142
0
12 1.2 (DL+LL+EQZ)
404.984 42.14194
0
13 1.5 (DL+EQZ)
495.234 51.53319
0
14 0.9DL+1.5EQZ
280.067 29.14329
0
15 1.2 (DL+LL-EQZ)
473.278 49.24849
0
16 1.5 (DL-EQZ)
580.601 60.41634
0
17 0.9DL-1.5EQZ
365.434 38.02643
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

6.7
5.21
6.6
3.89
5.51
6.97
4.26
19.89
24.78
27.49
30.61
38.35
35.63

3.42
33.95
42.46
41.08
28.49
35.58
36.96
2.59
3.26
1.88
2.88
3.63
2.25

67.239
95.69
118.578
92.0983
68.8605
84.9813
61.2614
64.6219
79.5732
58.5133
82.7385
102.396
75.9064

140
166
166
166
166
166
166
166
166
166
166
166
166

47
17.37
20.46
2.16
0.87
-0.12
-21.18
19.67
23.5
-0.23
15.76
18.44
0.15

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 67.23904 kN/m2
pmax = 118.5782 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
259 5 1.5 (DL+LL)
57.11904
6.7
F6-C14 6 1.2 (DL+LL+EQX)
56.52997
5.21
0
7 1.5 (DL+EQX)
69.51821
6.6
0
8 0.9DL+1.5EQX
47.1283
3.89
0
9 1.2 (DL+LL-EQX)
34.86046
5.51
0
10 1.5 (DL-EQX)
42.43132
6.97
0
11 0.9DL-1.5EQX
20.04142
4.26
0
12 1.2 (DL+LL+EQZ)
42.14194 19.89
0
13 1.5 (DL+EQZ)
51.53319 24.78
0
14 0.9DL+1.5EQZ
29.14329 27.49
0
15 1.2 (DL+LL-EQZ)
49.24849 30.61
0
16 1.5 (DL-EQZ)
60.41634 38.35
0
17 0.9DL-1.5EQZ
38.02643 35.63
Joint

kN/m2

Mzz/Zzz
(3)
3.42
33.95
42.46
41.08
28.49
35.58
36.96
2.59
3.26
1.88
2.88
3.63
2.25

pmin =

1+2+3

1-2+3

-21.18 kN/m2

1-2-3

1+2-3

67.24
53.84
47
60.4
95.69
85.27
17.37
27.79
118.579 105.379 20.459 33.659
92.099 84.319
2.159
9.939
68.861 57.841
0.861
11.881
84.982 71.042
-0.119 13.822
61.262 52.742 -21.179 -12.66
64.622 24.842
19.662 59.442
79.574 30.014
23.494 73.054
58.514
3.534
-0.227 54.754
82.739 21.519
15.759 76.979
102.397 25.697
18.437 95.137
75.907
4.647
0.147
71.407

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
259 5 1.5 (DL+LL)
918.394 95.56649
F6-C14 6 1.2 (DL+LL+EQX)
912.733 94.97742
0
7 1.5 (DL+EQX)
1037.55 107.9657
0
8 0.9DL+1.5EQX
822.383 85.57575
0
9 1.2 (DL+LL-EQX)
704.489 73.30791
0
10 1.5 (DL-EQX)
777.245 80.87877
0
11 0.9DL-1.5EQX
562.078 58.48887
0
12 1.2 (DL+LL+EQZ)
774.464 80.58939
0
13 1.5 (DL+EQZ)
864.714 89.98065
0
14 0.9DL+1.5EQZ
649.547 67.59074
0
15 1.2 (DL+LL-EQZ)
842.758 87.69594
0
16 1.5 (DL-EQZ)
950.081 98.86379
0
17 0.9DL-1.5EQZ
734.914 76.47388
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

6.7
5.21
6.6
3.89
5.51
6.97
4.26
19.89
24.78
27.49
30.61
38.35
35.63

3.42
33.95
42.46
41.08
28.49
35.58
36.96
2.59
3.26
1.88
2.88
3.63
2.25

105.686
134.137
157.026
130.546
107.308
123.429
99.7089
103.069
118.021
96.9607
121.186
140.844
114.354

140
166
166
166
166
166
166
166
166
166
166
166
166

85.45
55.82
58.91
40.61
39.31
38.33
17.27
58.11
61.95
38.23
54.21
56.89
38.6

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 105.6865 kN/m2
pmax = 157.0257 kN/m2
pmin =

85.45 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
259 5 1.5 (DL+LL)
95.56649
6.7
F6-C14 6 1.2 (DL+LL+EQX)
94.97742
5.21
0
7 1.5 (DL+EQX)
107.9657
6.6
0
8 0.9DL+1.5EQX
85.57575
3.89
0
9 1.2 (DL+LL-EQX)
73.30791
5.51
0
10 1.5 (DL-EQX)
80.87877
6.97
0
11 0.9DL-1.5EQX
58.48887
4.26
0
12 1.2 (DL+LL+EQZ)
80.58939 19.89
0
13 1.5 (DL+EQZ)
89.98065 24.78
0
14 0.9DL+1.5EQZ
67.59074 27.49
0
15 1.2 (DL+LL-EQZ)
87.69594 30.61
0
16 1.5 (DL-EQZ)
98.86379 38.35
0
17 0.9DL-1.5EQZ
76.47388 35.63
Joint

Mzz/Zzz
(3)
3.42
33.95
42.46
41.08
28.49
35.58
36.96
2.59
3.26
1.88
2.88
3.63
2.25

pmin =

17.27

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

105.687
134.138
157.026
130.546
107.308
123.429
99.709
103.07
118.021
96.961
121.186
140.844
114.354

92.287
123.718
143.826
122.766
96.288
109.489
91.189
63.29
68.461
41.981
59.966
64.144
43.094

85.447
55.818
58.906
40.606
39.308
38.329
17.269
58.11
61.941
38.221
54.206
56.884
38.594

98.847
66.238
72.106
48.386
50.328
52.269
25.789
97.89
111.5
93.201
115.43
133.58
109.85

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
259
F6-C14
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
37.32202 572.69
6 1.2 (DL+LL+EQX)
170.539 572.69
7 1.5 (DL+EQX)
213.3582 572.69
8 0.9DL+1.5EQX
204.9087 572.69
9 1.2 (DL+LL-EQX)
144.06
572.69
10 1.5 (DL-EQX)
180.0427 572.69
11 0.9DL-1.5EQX
184.7258 572.69
12 1.2 (DL+LL+EQZ)
99.59593 572.69
13 1.5 (DL+EQZ)
124.0722 572.69
14 0.9DL+1.5EQZ
136.8118 572.69
15 1.2 (DL+LL-EQZ)
152.6383 572.69
16 1.5 (DL-EQZ)
191.2483 572.69
17 0.9DL-1.5EQZ
177.2749 572.69

850.82
842.05
1035.51
702
519.27
632.04
298.53
627.73
767.62
434.11
733.59
899.94
566.43

38.15
8.3
7.54
6.23
7.58
6.7
4.72
12.06
10.81
7.36
8.56
7.71
6.43

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
35.73726
76.07055
95.46115
85.78554
54.02458
67.71739
68.13931
15.80575
19.46228
26.83126
63.08151
79.53199
65.48168

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3100
3100
425
0.242

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
918.39
912.73
1037.6
822.38
704.49
777.25
562.08
774.46
864.71
649.55
842.76
950.08
734.91

12.85
6
5.44
4.8
6.53
5.74
4.13
24.5
22.22
12.11
6.68
5.98
5.62

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column =
668.07 kN
Punching Shear,P =
668.07 x (( 3.1 x 3.1 ) - ( 0.925 x 1.175 ))
( 3.1 * 3.1 )
P = 592.52 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

925
1175
4200

mm
mm
mm

Depth Required 592520


=
1.37 x4200
= 102.98 mm
Shear Resistance = 1.37 x 4200 x 425 / 1000
2445
kN
157.026

kN/m2

B) One Way Shear


750
0

1175

136.481

kN/m2

124.839

kN/m2

425

500

3100

750

500
200
1300
425

875

3100

143.826

kN/m2
151.491 kN/m2

157.026

kN/m2

153.301

kN/m2

72.106

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 153.301 - 25 x 0.5 - 18 x ( 2 113.801 kN/m2
-- For without
Length at critical section =
3100
mm
Width at critical section =
750
mm
Shear Force = 113.801 x 3.1 x 0.75
= 264.5873 kN
At Width
Maximum Pressure = 136.481 - 25 x 0.5 - 18 x ( 2 96.981 kN/m2
-- For without
Length at critical section =
3100
mm
Width at critical section =
875
mm
Shear Force = 96.981 x 3.1 x 0.875
= 263.061 kN

0.5 )
Buoynacy Condition With Stress Increse

0.5 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 264.58733 kN


Corresponding Length =
3100
mm
% Ast =

0.242

Allowable Shear Stress =


0.362
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.362 x 1
2

N/mm
=
0.362
Depth Required = 264587.33
0.362 x 3100
=
311
mm
Check For Depth @ Critical Section
Critical section from face of
column =
425
mm
Min. Length from column face to
edge of footing =
1175
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
500
Depth @ Critical s/c =
391.49
Effe. Depth @ Critical s/c =
316.49
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 157.026
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 120.13 + 249.345 ) / ( 3.1 x 3.1 )
38.45
118.576 kN/m2
1.3

Bending Moment = 118.576 x 1.3 x 1.3 / 2


= 100.2 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

1013.41
0.2
850
16
200.96
198
195

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1030.56

mm

Provide 16 mm dia Bars @ 195 mm spacing bothways

i.e.0.243%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. = 369.475 kN
Area Load = 369.475 / (3.1 x 3.1)
38.45
Maxi. Projection of fdn =

1.3

kN/m2
m

Bending Moment = 38.45 x 1.3 x 1.3 / 2


=
Ast =

32.49

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

321.12

Mini % of Re-bar =

0.12

Ast =
Use

510
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

221
220

mm
mm
2
Area Provided = 513.819 mm
Provide 12 mm dia Bars @ 220 mm spacing bothways

i.e.0.121%

Summary Of Design :Length Of Footing :3100 mm


WIdth Of Footing :3100 mm
Depth Of Footing :500
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 220 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 195 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3
3.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.425

Wp

1.425
Z

1.25

Lp

F7

COLUMN NO.

C15

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.25

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3 x 3.6 x 0.6
=
162
kN
Buoyant Self wt. of Fdn = 0 x 3 x 3.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3 x 3.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
262.71 kN
Buoyant weight of Soil = [(3 x 3.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 162 + 0 + 262.71


=
424.71 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
270
F7-C15

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
5.838
704.052
6 1.2 (DL+LL+EQX)
-17.989 555.729
7 1.5 (DL+EQX)
-22.384 681.164
8 0.9DL+1.5EQX
-24.76
404.942
9 1.2 (DL+LL-EQX)
27.33
570.753
10 1.5 (DL-EQX)
34.264
699.943
11 0.9DL-1.5EQX
31.888
423.722
12 1.2 (DL+LL+EQZ)
5.07
563.193
13 1.5 (DL+EQZ)
6.439
690.493
14 0.9DL+1.5EQZ
4.063
414.272
15 1.2 (DL+LL-EQZ)
4.272
563.289
16 1.5 (DL-EQZ)
5.441
690.613
17 0.9DL-1.5EQZ
3.065
414.392

kN - m)
FORCE-Z
-11.743
-9.869
-12.452
-7.709
-8.92
-11.267
-6.523
-86.271
-107.96
-103.21
67.483
84.237
88.981

MOM-X
-22.67
-18.713
-23.629
-14.466
-17.559
-22.187
-13.024
-224.04
-280.287
-271.124
187.767
234.471
243.635

MOM-Y
2.644
7.264
9.086
8.026
-3.034
-3.786
-4.846
-4.701
-5.87
-6.93
8.931
11.17
10.11

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3 x 3.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

10.8

m2

1/6 x 3 x 3.6 x 3.6


6.48

m3

1/6 x 3.6 x 3 x 3
5.4

m3

Total Vertical Load P = 704.052 + 424.71


= 1128.762 kN

MOM Z
-13.919
162.889
203.535
209.134
-185.16
-231.526
-225.928
-11.992
-15.066
-9.468
-10.279
-12.925
-7.327

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1128.762 / (3 x 3.6 )


=

104.515

kN/m

Mxx/Zxx = 22.67 / 6.48


Mxx/Zxx =

3.499

kN/m

Mzz/Zzz = 13.919 / 5.4


Mzz/Zzz =

2.578

kN/m

Maxi.Soil Pressure pmax = 104.515 + 3.499 + 2.578


pmax =

110.60

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 104.515 - 3.499 - 2.578
pmin =

98.44

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
26.61
kN.m
Calculation of Stabilizing Moment
Due to External Load = 704.052 x 3 / 2
=
1056.08 kN.m
Due to wt. of Pedestral = 0 x 1.5
=
0

kN.m

Due to Self Wt. of Fdn = 162 x 1.5


=
243
kN.m
Due to Wt. of Soil = 262.71 x 1.5
=
394.07 kN.m
Total Stabilizing moment = 1056.08 + 0 + 243 + 394.07
=
1693.15 kN.m
F.O.S. against Overturning = 1693.15 / 26.61
= 63.6283 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

13.12

kN

Total Vertical Load = 1128.76 kN


F.O.S. against Sliding = 1128.762 x 0.5 / 13.12
= 43.02
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
270 5 1.5 (DL+LL)
704.052
65.19
F7-C15 6 1.2 (DL+LL+EQX)
555.729 51.45639
0
7 1.5 (DL+EQX)
681.164 63.07074
0
8 0.9DL+1.5EQX
404.942 37.49463
0
9 1.2 (DL+LL-EQX)
570.753 52.8475
0
10 1.5 (DL-EQX)
699.943 64.80954
0
11 0.9DL-1.5EQX
423.722 39.23352
0
12 1.2 (DL+LL+EQZ)
563.193 52.1475
0
13 1.5 (DL+EQZ)
690.493 63.93454
0
14 0.9DL+1.5EQZ
414.272 38.35852
0
15 1.2 (DL+LL-EQZ)
563.289 52.15639
0
16 1.5 (DL-EQZ)
690.613 63.94565
0
17 0.9DL-1.5EQZ
414.392 38.36963
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

3.5
2.89
3.65
2.24
2.71
3.43
2.01
34.58
43.26
41.85
28.98
36.19
37.6

2.58
30.17
37.7
38.73
34.29
42.88
41.84
2.23
2.79
1.76
1.91
2.4
1.36

71.27
84.5164
104.421
78.4646
89.8475
111.12
83.0835
88.9575
109.985
81.9685
83.0464
102.536
77.3296

140
166
166
166
166
166
166
166
166
166
166
166
166

59.11
18.4
21.73
-3.48
15.85
18.5
-4.62
15.34
17.89
-5.26
21.27
25.36
-0.6

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax =
pmax = 111.1195 kN/m2
71.27 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
270 5 1.5 (DL+LL)
65.19
3.5
F7-C15 6 1.2 (DL+LL+EQX)
51.45639
2.89
0
7 1.5 (DL+EQX)
63.07074
3.65
0
8 0.9DL+1.5EQX
37.49463
2.24
0
9 1.2 (DL+LL-EQX)
52.8475
2.71
0
10 1.5 (DL-EQX)
64.80954
3.43
0
11 0.9DL-1.5EQX
39.23352
2.01
0
12 1.2 (DL+LL+EQZ)
52.1475 34.58
0
13 1.5 (DL+EQZ)
63.93454 43.26
0
14 0.9DL+1.5EQZ
38.35852 41.85
0
15 1.2 (DL+LL-EQZ)
52.15639 28.98
0
16 1.5 (DL-EQZ)
63.94565 36.19
0
17 0.9DL-1.5EQZ
38.36963
37.6
Joint

kN/m2

Mzz/Zzz
(3)
2.58
30.17
37.7
38.73
34.29
42.88
41.84
2.23
2.79
1.76
1.91
2.4
1.36

pmin =

-5.26

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

71.27
84.517
104.421
78.465
89.848
111.12
83.084
88.958
109.985
81.969
83.047
102.536
77.33

64.27
78.737
97.121
73.985
84.428
104.26
79.064
19.798
23.465
-1.732
25.087
30.156
2.13

59.11
18.397
21.721
-3.476
15.848
18.5
-4.617
15.338
17.885
-5.252
21.267
25.356
-0.591

66.11
24.177
29.021
1.005
21.268
25.36
-0.597
84.498
104.41
78.449
79.227
97.736
74.61

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
270 5 1.5 (DL+LL)
1128.762 104.515
F7-C15 6 1.2 (DL+LL+EQX)
980.439 90.78139
0
7 1.5 (DL+EQX)
1105.874 102.3957
0
8 0.9DL+1.5EQX
829.652 76.81963
0
9 1.2 (DL+LL-EQX)
995.463 92.1725
0
10 1.5 (DL-EQX)
1124.653 104.1345
0
11 0.9DL-1.5EQX
848.432 78.55852
0
12 1.2 (DL+LL+EQZ)
987.903 91.4725
0
13 1.5 (DL+EQZ)
1115.203 103.2595
0
14 0.9DL+1.5EQZ
838.982 77.68352
0
15 1.2 (DL+LL-EQZ)
987.999 91.48139
0
16 1.5 (DL-EQZ)
1115.323 103.2706
0
17 0.9DL-1.5EQZ
839.102 77.69463
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

3.5
2.89
3.65
2.24
2.71
3.43
2.01
34.58
43.26
41.85
28.98
36.19
37.6

2.58
30.17
37.7
38.73
34.29
42.88
41.84
2.23
2.79
1.76
1.91
2.4
1.36

110.595
123.841
143.746
117.79
129.173
150.445
122.409
128.283
149.31
121.294
122.371
141.861
116.655

140
166
166
166
166
166
166
166
166
166
166
166
166

98.44
57.73
61.05
35.85
55.18
57.83
34.71
54.67
57.21
34.08
60.6
64.69
38.74

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 110.595 kN/m2
pmax = 150.4445 kN/m2
pmin =

98.44 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
270 5 1.5 (DL+LL)
104.515
3.5
F7-C15 6 1.2 (DL+LL+EQX)
90.78139
2.89
0
7 1.5 (DL+EQX)
102.3957
3.65
0
8 0.9DL+1.5EQX
76.81963
2.24
0
9 1.2 (DL+LL-EQX)
92.1725
2.71
0
10 1.5 (DL-EQX)
104.1345
3.43
0
11 0.9DL-1.5EQX
78.55852
2.01
0
12 1.2 (DL+LL+EQZ)
91.4725 34.58
0
13 1.5 (DL+EQZ)
103.2595 43.26
0
14 0.9DL+1.5EQZ
77.68352 41.85
0
15 1.2 (DL+LL-EQZ)
91.48139 28.98
0
16 1.5 (DL-EQZ)
103.2706 36.19
0
17 0.9DL-1.5EQZ
77.69463
37.6
Joint

Mzz/Zzz
(3)
2.58
30.17
37.7
38.73
34.29
42.88
41.84
2.23
2.79
1.76
1.91
2.4
1.36

pmin =

34.08

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

110.595
123.842
143.746
117.79
129.173
150.445
122.409
128.283
149.31
121.294
122.372
141.861
116.655

103.595
118.062
136.446
113.31
123.753
143.585
118.389
59.123
62.79
37.594
64.412
69.481
41.455

98.435
57.722
61.046
35.85
55.173
57.825
34.709
54.663
57.21
34.074
60.592
64.681
38.735

105.44
63.502
68.346
40.33
60.593
64.685
38.729
123.82
143.73
117.77
118.55
137.06
113.94

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
270
F7-C15
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
26.60202 637.07
6 1.2 (DL+LL+EQX)
163.9604 637.07
7 1.5 (DL+EQX)
204.902 637.07
8 0.9DL+1.5EQX
209.6337 637.07
9 1.2 (DL+LL-EQX)
185.9907 637.07
10 1.5 (DL-EQX)
232.5867 637.07
11 0.9DL-1.5EQX
226.3031 637.07
12 1.2 (DL+LL+EQZ)
224.3607 637.07
13 1.5 (DL+EQZ)
280.6916 637.07
14 0.9DL+1.5EQZ
271.2893 637.07
15 1.2 (DL+LL-EQZ)
188.0481 637.07
16 1.5 (DL-EQZ)
234.827 637.07
17 0.9DL-1.5EQZ
243.7452 637.07

1056.08
833.6
1021.75
607.42
856.13
1049.92
635.59
844.79
1035.74
621.41
844.94
1035.92
621.59

63.65
8.97
8.1
5.94
8.03
7.26
5.63
6.61
5.96
4.64
7.89
7.13
5.17

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
13.11413
20.51832
25.61437
25.93234
28.74883
36.06892
32.54833
86.41985
108.1479
103.2919
67.61808
84.41254
89.03377

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3000
3600
525
0.255

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1128.8
980.44
1105.9
829.65
995.46
1124.7
848.43
987.9
1115.2
838.98
988
1115.3
839.1

43.04
23.9
21.59
16
17.32
15.6
13.04
5.72
5.16
4.07
7.31
6.61
4.72

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 704.052 kN
Punching Shear,P =
704.052 x (( 3 x 3.6 ) - ( 1.025 x 1.275 ))
( 3 * 3.6 )
P = 618.86 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 618860


=
1.37 x4600
=
98.2
mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
150.445

kN/m2

B) One Way Shear


900
0

1425

129.005

kN/m2

116.499

kN/m2

525

600

3600

750

500
200
1250
525

725

3000

143.585

kN/m2
147.587 kN/m2

150.445

kN/m2

148.788

kN/m2

64.685

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 148.788 - 25 x 0.6 - 18 x ( 2 108.588 kN/m2
-- For without
Length at critical section =
3000
mm
Width at critical section =
900
mm
Shear Force = 108.588 x 3 x 0.9
= 293.1876 kN
At Width
Maximum Pressure = 129.005 - 25 x 0.6 - 18 x ( 2 88.805 kN/m2
-- For without
Length at critical section =
3600
mm
Width at critical section =
725
mm
Shear Force = 88.805 x 3.6 x 0.725
= 231.7811 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 293.1876 kN


Corresponding Length =
3000
mm
% Ast =

0.255

Allowable Shear Stress =


0.37
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.37 x 1
2

N/mm
=
0.37
Depth Required = 293187.6
0.37 x 3000
=
340
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm
Min. Length from column face to
edge of footing =
1250
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
432
Effe. Depth @ Critical s/c =
357
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 150.445
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 162 + 262.71 ) / ( 3 x 3.6 )
39.33
111.115 kN/m2
1.425

Bending Moment = 111.115 x 1.425 x 1.425 / 2


= 112.82 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

915.31
0.2
1050
16
200.96
191
150

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1339.73

mm

Provide 16 mm dia Bars @ 150 mm spacing bothways

i.e.0.256%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
424.71 kN
Area Load = 424.71 / (3 x 3.6)

Maxi. Projection of fdn =

39.33

kN/m2

1.425

Bending Moment = 39.33 x 1.425 x 1.425 / 2


=
Ast =

39.93

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

318.82

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3000 mm


WIdth Of Footing :3600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 150 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3
4
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.625

Wp

1.625
Z

1.25

Lp

F8

COLUMN NO.

C16

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.25

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3 x 4 x 0.6


=
180
kN
Buoyant Self wt. of Fdn = 0 x 3 x 4 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3 x 4) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
292.95 kN
Buoyant weight of Soil = [(3 x 4) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 180 + 0 + 292.95


=
472.95 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
265
F8-C16

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-4.953
886.62
6 1.2 (DL+LL+EQX)
-49.187 721.265
7 1.5 (DL+EQX)
-60.974 856.639
8 0.9DL+1.5EQX
-59.197 519.968
9 1.2 (DL+LL-EQX)
41.262
697.326
10 1.5 (DL-EQX)
52.087
826.716
11 0.9DL-1.5EQX
53.864
490.045
12 1.2 (DL+LL+EQZ)
-4.028
708.258
13 1.5 (DL+EQZ)
-4.527
840.38
14 0.9DL+1.5EQZ
-2.749
503.709
15 1.2 (DL+LL-EQZ)
-3.896
710.333
16 1.5 (DL-EQZ)
-4.361
842.974
17 0.9DL-1.5EQZ
-2.584
506.303

kN - m)
FORCE-Z
13.624
11.305
14.122
8.676
10.494
13.107
7.661
-99.152
-123.95
-129.4
120.951
151.179
145.733

MOM-X
10.251
9.178
11.492
7.384
7.224
9.049
4.941
-286.997
-358.726
-362.835
303.399
379.267
375.159

MOM-Y
2.616
7.282
8.869
7.916
-3.097
-4.104
-5.057
-0.645
-1.039
-1.992
4.83
5.804
4.851

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3 x 4
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

12

m2

1/6 x 3 x 4 x 4
8

m3

1/6 x 4 x 3 x 3
6

m3

Total Vertical Load P = 886.62 + 472.95


= 1359.57 kN

MOM Z
16.016
251.212
312.41
306.645
-225.585
-283.586
-289.351
13.037
14.692
8.927
12.589
14.132
8.367

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1359.57 / (3 x 4 )
=

113.298

kN/m

Mxx/Zxx = 10.251 / 8
Mxx/Zxx =

1.282

kN/m

Mzz/Zzz = 16.016 / 6
Mzz/Zzz =

2.670

kN/m

Maxi.Soil Pressure pmax = 113.298 + 1.282 + 2.67


pmax =

117.25

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 113.298 - 1.282 - 2.67
pmin =

109.35

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
19.02
kN.m
Calculation of Stabilizing Moment
Due to External Load = 886.62 x 3 / 2
=
1329.93 kN.m
Due to wt. of Pedestral = 0 x 1.5
=
0

kN.m

Due to Self Wt. of Fdn = 180 x 1.5


=
270
kN.m
Due to Wt. of Soil = 292.95 x 1.5
=
439.43 kN.m
Total Stabilizing moment = 1329.93 + 0 + 270 + 439.43
=
2039.36 kN.m
F.O.S. against Overturning = 2039.36 / 19.02
= 107.222 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

14.5

kN

Total Vertical Load = 1359.57 kN


F.O.S. against Sliding = 1359.57 x 0.5 / 14.5
= 46.89
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
265 5 1.5 (DL+LL)
886.62
73.885
F8-C16 6 1.2 (DL+LL+EQX)
721.265 60.10542
0
7 1.5 (DL+EQX)
856.639 71.38658
0
8 0.9DL+1.5EQX
519.968 43.33067
0
9 1.2 (DL+LL-EQX)
697.326 58.1105
0
10 1.5 (DL-EQX)
826.716 68.893
0
11 0.9DL-1.5EQX
490.045 40.83708
0
12 1.2 (DL+LL+EQZ)
708.258 59.0215
0
13 1.5 (DL+EQZ)
840.38 70.03167
0
14 0.9DL+1.5EQZ
503.709 41.97575
0
15 1.2 (DL+LL-EQZ)
710.333 59.19442
0
16 1.5 (DL-EQZ)
842.974 70.24783
0
17 0.9DL-1.5EQZ
506.303 42.19192
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

1.29
1.15
1.44
0.93
0.91
1.14
0.62
35.88
44.85
45.36
37.93
47.41
46.9

2.67
41.87
52.07
51.11
37.6
47.27
48.23
2.18
2.45
1.49
2.1
2.36
1.4

77.845
103.125
124.897
95.3707
96.6205
117.303
89.6871
97.0815
117.332
88.8258
99.2244
120.018
90.4919

140
166
166
166
166
166
166
166
166
166
166
166
166

69.93
17.09
17.88
-8.71
19.61
20.49
-8.02
20.97
22.74
-4.88
19.17
20.48
-6.11

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax =
pmax = 124.8966 kN/m2
77.845 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
265 5 1.5 (DL+LL)
73.885
1.29
F8-C16 6 1.2 (DL+LL+EQX)
60.10542
1.15
0
7 1.5 (DL+EQX)
71.38658
1.44
0
8 0.9DL+1.5EQX
43.33067
0.93
0
9 1.2 (DL+LL-EQX)
58.1105
0.91
0
10 1.5 (DL-EQX)
68.893
1.14
0
11 0.9DL-1.5EQX
40.83708
0.62
0
12 1.2 (DL+LL+EQZ)
59.0215 35.88
0
13 1.5 (DL+EQZ)
70.03167 44.85
0
14 0.9DL+1.5EQZ
41.97575 45.36
0
15 1.2 (DL+LL-EQZ)
59.19442 37.93
0
16 1.5 (DL-EQZ)
70.24783 47.41
0
17 0.9DL-1.5EQZ
42.19192
46.9
Joint

kN/m2

Mzz/Zzz
(3)
2.67
41.87
52.07
51.11
37.6
47.27
48.23
2.18
2.45
1.49
2.1
2.36
1.4

pmin =

1+2+3

1-2+3

77.845 75.265
103.126 100.826
124.897 122.017
95.371 93.511
96.621 94.801
117.303 115.023
89.688 88.448
97.082 25.322
117.332 27.632
88.826 -1.895
99.225 23.365
120.018 25.198
90.492 -3.309

-8.71

kN/m2

1-2-3

1+2-3

69.925
17.086
17.877
-8.71
19.601
20.483
-8.013
20.962
22.732
-4.875
19.165
20.478
-6.109

72.505
19.386
20.757
-6.85
21.421
22.763
-6.773
92.722
112.43
85.846
95.025
115.3
87.692

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
265 5 1.5 (DL+LL)
1359.57 113.2975
F8-C16 6 1.2 (DL+LL+EQX)
1194.215 99.51792
0
7 1.5 (DL+EQX)
1329.589 110.7991
0
8 0.9DL+1.5EQX
992.918 82.74317
0
9 1.2 (DL+LL-EQX)
1170.276 97.523
0
10 1.5 (DL-EQX)
1299.666 108.3055
0
11 0.9DL-1.5EQX
962.995 80.24958
0
12 1.2 (DL+LL+EQZ)
1181.208 98.434
0
13 1.5 (DL+EQZ)
1313.33 109.4442
0
14 0.9DL+1.5EQZ
976.659 81.38825
0
15 1.2 (DL+LL-EQZ)
1183.283 98.60692
0
16 1.5 (DL-EQZ)
1315.924 109.6603
0
17 0.9DL-1.5EQZ
979.253 81.60442
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

1.29
1.15
1.44
0.93
0.91
1.14
0.62
35.88
44.85
45.36
37.93
47.41
46.9

2.67
41.87
52.07
51.11
37.6
47.27
48.23
2.18
2.45
1.49
2.1
2.36
1.4

117.258
142.538
164.309
134.783
136.033
156.716
129.1
136.494
156.744
128.238
138.637
159.43
129.904

140
166
166
166
166
166
166
166
166
166
166
166
166

109.34
56.5
57.29
30.71
59.02
59.9
31.4
60.38
62.15
34.54
58.58
59.9
33.31

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 117.2575 kN/m2
pmax = 164.3091 kN/m2
pmin =

109.34 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
265 5 1.5 (DL+LL)
113.2975
1.29
F8-C16 6 1.2 (DL+LL+EQX)
99.51792
1.15
0
7 1.5 (DL+EQX)
110.7991
1.44
0
8 0.9DL+1.5EQX
82.74317
0.93
0
9 1.2 (DL+LL-EQX)
97.523
0.91
0
10 1.5 (DL-EQX)
108.3055
1.14
0
11 0.9DL-1.5EQX
80.24958
0.62
0
12 1.2 (DL+LL+EQZ)
98.434 35.88
0
13 1.5 (DL+EQZ)
109.4442 44.85
0
14 0.9DL+1.5EQZ
81.38825 45.36
0
15 1.2 (DL+LL-EQZ)
98.60692 37.93
0
16 1.5 (DL-EQZ)
109.6603 47.41
0
17 0.9DL-1.5EQZ
81.60442
46.9
Joint

Mzz/Zzz
(3)
2.67
41.87
52.07
51.11
37.6
47.27
48.23
2.18
2.45
1.49
2.1
2.36
1.4

pmin =

1+2+3
117.258
142.538
164.31
134.784
136.033
156.716
129.1
136.494
156.745
128.239
138.637
159.431
129.905

1-2+3

30.71

1-2-3

kN/m2

1+2-3

114.678 109.338 111.92


140.238 56.498 58.798
161.43
57.29
60.17
132.924 30.704 32.564
134.213 59.013 60.833
154.436 59.896 62.176
127.86
31.4
32.64
64.734
60.374 132.13
67.045
62.145 151.85
37.519
34.539 125.26
62.777
58.577 134.44
64.611
59.891 154.71
36.105
33.305 127.11

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
265
F8-C16
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
19.01566 709.43
6 1.2 (DL+LL+EQX)
251.3796 709.43
7 1.5 (DL+EQX)
312.6213 709.43
8 0.9DL+1.5EQX
306.7339 709.43
9 1.2 (DL+LL-EQX)
225.7006 709.43
10 1.5 (DL-EQX)
283.7303 709.43
11 0.9DL-1.5EQX
289.3932 709.43
12 1.2 (DL+LL+EQZ)
287.293 709.43
13 1.5 (DL+EQZ)
359.0267 709.43
14 0.9DL+1.5EQZ
362.9448 709.43
15 1.2 (DL+LL-EQZ)
303.6601 709.43
16 1.5 (DL-EQZ)
379.5302 709.43
17 0.9DL-1.5EQZ
375.2523 709.43

1329.93
1081.9
1284.96
779.96
1045.99
1240.08
735.07
1062.39
1260.57
755.57
1065.5
1264.47
759.46

107.25
7.13
6.38
4.86
7.78
6.88
5
6.17
5.49
4.04
5.85
5.21
3.92

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
14.4964
50.46944
62.58801
59.82941
42.57554
53.71079
54.40608
99.23378
124.0326
129.4252
121.0137
151.2419
145.7559

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3000
4000
525
0.478

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1359.6
1194.2
1329.6
992.92
1170.3
1299.7
963
1181.2
1313.3
976.66
1183.3
1315.9
979.25

46.9
11.84
10.63
8.3
13.75
12.1
8.86
5.96
5.3
3.78
4.89
4.36
3.36

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column =
886.62 kN
Punching Shear,P =
886.62 x (( 3 x 4 ) - ( 1.025 x 1.275 ))
( 3 * 4 )
P = 790.07 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 790070


=
1.37 x4600
= 125.37 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
164.31

kN/m2

B) One Way Shear


1100
0

1625

135.672

kN/m2

122.004

kN/m2

525

600

4000

750

500
200
1250
525

725

3000

161.43

kN/m2
163.11 kN/m2

164.31

kN/m2

163.614

kN/m2

60.17

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 163.614 - 25 x 0.6
123.414 kN/m2
Length at critical section =
3000
Width at critical section =
1100
Shear Force = 123.414 x 3 x 1.1
= 407.2662 kN
At Width
Maximum Pressure = 135.672 - 25 x 0.6
95.472 kN/m2
Length at critical section =
4000
Width at critical section =
725
Shear Force = 95.472 x 4 x 0.725
= 276.8688 kN

- 18 x ( 2 - 0.6 )
-- For without Buoynacy Condition With Stress Increse

mm
mm

- 18 x ( 2 - 0.6 )
-- For without Buoynacy Condition With Stress Increse

mm
mm

Designed Shear Strength = 407.2662 kN


Corresponding Length =
3000
mm
% Ast =

0.478

Allowable Shear Stress =


0.4844 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.4844 x 1
2
=
0.4844 N/mm
Depth Required = 407266.2
0.4844 x 3000
=
356
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm

Min. Length from column face to


edge of footing =
1250
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
432
Effe. Depth @ Critical s/c =
357
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure =
164.31
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 180 + 292.95 ) / ( 3 x 4 )
39.41
124.9 kN/m2
1.625

Bending Moment = 124.9 x 1.625 x 1.625 / 2


= 164.91 kN.m
Ast =
0.5 x fck x b x d

1 -

1353.96
0.2

Ast =
Use

1050
20

Area of bar =
Spacing =
Provide Spacing =

314
231
125

1-

(4.6 x Mu )
fck x b x d2

fy
Ast =
Mini.% of re-bar =

SAG

mm2
%
mm2
mm dia bars
mm2
mm

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

2512

mm

Provide 20 mm dia Bars @ 125 mm spacing bothways

i.e.0.479%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
472.95 kN
Area Load = 472.95 / (3 x 4)

Maxi. Projection of fdn =

39.41

kN/m2

1.625

Bending Moment = 39.41 x 1.625 x 1.625 / 2


=
Ast =

52.03

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

416.51

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3000 mm


WIdth Of Footing :4000 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 20 mm dia Bars @ 125 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

SLOPED
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
3
3.6
0.6
0.2
0.75
0.5
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.425

Wp

1.425
Z

1.25

Lp

F7

COLUMN NO.

C17

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

1.25

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 3 x 3.6 x 0.6
=
162
kN
Buoyant Self wt. of Fdn = 0 x 3 x 3.6 x 0.6
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(3 x 3.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 18


=
262.71 kN
Buoyant weight of Soil = [(3 x 3.6) - (0.5 x 0.75)] x (2 - 0.6 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.75 x 0.5 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 162 + 0 + 262.71


=
424.71 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
266
F7-C17

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-5.416
687.282
6 1.2 (DL+LL+EQX)
-50.293 564.591
7 1.5 (DL+EQX)
-62.412 689.666
8 0.9DL+1.5EQX
-60.428 421.182
9 1.2 (DL+LL-EQX)
41.629
535.06
10 1.5 (DL-EQX)
52.49
652.752
11 0.9DL-1.5EQX
54.475
384.268
12 1.2 (DL+LL+EQZ)
-3.971
498.774
13 1.5 (DL+EQZ)
-4.508
607.394
14 0.9DL+1.5EQZ
-2.524
338.91
15 1.2 (DL+LL-EQZ)
-4.694
600.878
16 1.5 (DL-EQZ)
-5.413
735.024
17 0.9DL-1.5EQZ
-3.429
466.54

kN - m)
FORCE-Z
-19.735
-15.326
-19.75
-11.619
-16.25
-20.905
-12.774
-72.369
-91.052
-82.922
40.792
50.398
58.529

MOM-X
-24.914
-19.992
-25.604
-15.393
-19.87
-25.452
-15.241
-168.03
-210.652
-200.44
128.168
159.596
169.807

MOM-Y
-0.314
24.624
30.825
30.933
-25.13
-31.37
-31.26
1.816
2.315
2.423
-2.319
-2.855
-2.747

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 3 x 3.6
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

10.8

m2

1/6 x 3 x 3.6 x 3.6


6.48

m3

1/6 x 3.6 x 3 x 3
5.4

m3

Total Vertical Load P = 687.282 + 424.71


= 1111.992 kN

MOM Z
8.636
220.44
274.716
271.595
-206.623
-259.112
-262.233
5.151
5.605
2.484
8.666
9.999
6.879

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 1111.992 / (3 x 3.6 )


=

102.962

kN/m

Mxx/Zxx = 24.914 / 6.48


Mxx/Zxx =

3.845

kN/m

Mzz/Zzz = 8.636 / 5.4


Mzz/Zzz =

1.600

kN/m

Maxi.Soil Pressure pmax = 102.962 + 3.845 + 1.6


pmax =

108.41

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 102.962 - 3.845 - 1.6
pmin =

97.52

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
26.37
kN.m
Calculation of Stabilizing Moment
Due to External Load = 687.282 x 3 / 2
=
1030.93 kN.m
Due to wt. of Pedestral = 0 x 1.5
=
0

kN.m

Due to Self Wt. of Fdn = 162 x 1.5


=
243
kN.m
Due to Wt. of Soil = 262.71 x 1.5
=
394.07 kN.m
Total Stabilizing moment = 1030.93 + 0 + 243 + 394.07
=
1668 kN.m
F.O.S. against Overturning = 1668 / 26.37
= 63.2537 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

20.47

kN

Total Vertical Load = 1111.99 kN


F.O.S. against Sliding = 1111.992 x 0.5 / 20.47
= 27.17
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
266 5 1.5 (DL+LL)
687.282 63.63722
F7-C17 6 1.2 (DL+LL+EQX)
564.591 52.27694
0
7 1.5 (DL+EQX)
689.666 63.85796
0
8 0.9DL+1.5EQX
421.182 38.99833
0
9 1.2 (DL+LL-EQX)
535.06 49.54259
0
10 1.5 (DL-EQX)
652.752
60.44
0
11 0.9DL-1.5EQX
384.268 35.58037
0
12 1.2 (DL+LL+EQZ)
498.774 46.18278
0
13 1.5 (DL+EQZ)
607.394 56.24019
0
14 0.9DL+1.5EQZ
338.91 31.38056
0
15 1.2 (DL+LL-EQZ)
600.878 55.63685
0
16 1.5 (DL-EQZ)
735.024 68.05778
0
17 0.9DL-1.5EQZ
466.54 43.19815
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

3.85
3.09
3.96
2.38
3.07
3.93
2.36
25.94
32.51
30.94
19.78
24.63
26.21

1.6
40.83
50.88
50.3
38.27
47.99
48.57
0.96
1.04
0.46
1.61
1.86
1.28

69.0872
96.1969
118.698
91.6783
90.8826
112.36
86.5104
73.0828
89.7902
62.7806
77.0269
94.5478
70.6881

140
166
166
166
166
166
166
166
166
166
166
166
166

58.19
8.36
9.02
-13.69
8.21
8.52
-15.35
19.29
22.7
-0.02
34.25
41.57
15.71

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 69.08722 kN/m2
pmax = 118.698 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
266 5 1.5 (DL+LL)
63.63722
3.85
F7-C17 6 1.2 (DL+LL+EQX)
52.27694
3.09
0
7 1.5 (DL+EQX)
63.85796
3.96
0
8 0.9DL+1.5EQX
38.99833
2.38
0
9 1.2 (DL+LL-EQX)
49.54259
3.07
0
10 1.5 (DL-EQX)
60.44
3.93
0
11 0.9DL-1.5EQX
35.58037
2.36
0
12 1.2 (DL+LL+EQZ)
46.18278 25.94
0
13 1.5 (DL+EQZ)
56.24019 32.51
0
14 0.9DL+1.5EQZ
31.38056 30.94
0
15 1.2 (DL+LL-EQZ)
55.63685 19.78
0
16 1.5 (DL-EQZ)
68.05778 24.63
0
17 0.9DL-1.5EQZ
43.19815 26.21
Joint

kN/m2

Mzz/Zzz
(3)
1.6
40.83
50.88
50.3
38.27
47.99
48.57
0.96
1.04
0.46
1.61
1.86
1.28

pmin =

1+2+3

1-2+3

-15.35 kN/m2

1-2-3

1+2-3

69.088 61.388
58.188 65.888
96.197 90.017
8.357
14.537
118.698 110.778
9.018
16.938
91.679 86.919 -13.682 -8.922
90.883 84.743
8.203
14.343
112.36
104.5
8.52
16.38
86.511 81.791
-15.35 -10.63
73.083 21.203
19.283 71.163
89.791 24.771
22.691 87.711
62.781
0.901
-0.02
61.861
77.027 37.467
34.247 73.807
94.548 45.288
41.568 90.828
70.689 18.269
15.709 68.129

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
266 5 1.5 (DL+LL)
1111.992 102.9622
F7-C17 6 1.2 (DL+LL+EQX)
989.301 91.60194
0
7 1.5 (DL+EQX)
1114.376 103.183
0
8 0.9DL+1.5EQX
845.892 78.32333
0
9 1.2 (DL+LL-EQX)
959.77 88.86759
0
10 1.5 (DL-EQX)
1077.462 99.765
0
11 0.9DL-1.5EQX
808.978 74.90537
0
12 1.2 (DL+LL+EQZ)
923.484 85.50778
0
13 1.5 (DL+EQZ)
1032.104 95.56519
0
14 0.9DL+1.5EQZ
763.62 70.70556
0
15 1.2 (DL+LL-EQZ)
1025.588 94.96185
0
16 1.5 (DL-EQZ)
1159.734 107.3828
0
17 0.9DL-1.5EQZ
891.25 82.52315
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

3.85
3.09
3.96
2.38
3.07
3.93
2.36
25.94
32.51
30.94
19.78
24.63
26.21

1.6
40.83
50.88
50.3
38.27
47.99
48.57
0.96
1.04
0.46
1.61
1.86
1.28

108.412
135.522
158.023
131.003
130.208
151.685
125.835
112.408
129.115
102.106
116.352
133.873
110.013

140
166
166
166
166
166
166
166
166
166
166
166
166

97.52
47.69
48.35
25.65
47.53
47.85
23.98
58.61
62.02
39.31
73.58
80.9
55.04

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 108.4122 kN/m2
pmax = 158.023 kN/m2
pmin =

97.52 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
266 5 1.5 (DL+LL)
102.9622
3.85
F7-C17 6 1.2 (DL+LL+EQX)
91.60194
3.09
0
7 1.5 (DL+EQX)
103.183
3.96
0
8 0.9DL+1.5EQX
78.32333
2.38
0
9 1.2 (DL+LL-EQX)
88.86759
3.07
0
10 1.5 (DL-EQX)
99.765
3.93
0
11 0.9DL-1.5EQX
74.90537
2.36
0
12 1.2 (DL+LL+EQZ)
85.50778 25.94
0
13 1.5 (DL+EQZ)
95.56519 32.51
0
14 0.9DL+1.5EQZ
70.70556 30.94
0
15 1.2 (DL+LL-EQZ)
94.96185 19.78
0
16 1.5 (DL-EQZ)
107.3828 24.63
0
17 0.9DL-1.5EQZ
82.52315 26.21
Joint

Mzz/Zzz
(3)
1.6
40.83
50.88
50.3
38.27
47.99
48.57
0.96
1.04
0.46
1.61
1.86
1.28

pmin =

23.98

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

108.413
135.522
158.023
131.004
130.208
151.685
125.836
112.408
129.116
102.106
116.352
133.873
110.014

100.713
129.342
150.103
126.244
124.068
143.825
121.116
60.528
64.096
40.226
76.792
84.613
57.594

97.513
47.682
48.343
25.644
47.528
47.845
23.976
58.608
62.016
39.306
73.572
80.893
55.034

105.21
53.862
56.263
30.404
53.668
55.705
28.696
110.49
127.04
101.19
113.13
130.15
107.45

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
266
F7-C17
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
26.36831 637.07
6 1.2 (DL+LL+EQX)
221.3447 637.07
7 1.5 (DL+EQX)
275.9066 637.07
8 0.9DL+1.5EQX
272.0309 637.07
9 1.2 (DL+LL-EQX)
207.5762 637.07
10 1.5 (DL-EQX)
260.359 637.07
11 0.9DL-1.5EQX
262.6755 637.07
12 1.2 (DL+LL+EQZ)
168.1089 637.07
13 1.5 (DL+EQZ)
210.7266 637.07
14 0.9DL+1.5EQZ
200.4554 637.07
15 1.2 (DL+LL-EQZ)
128.4606 637.07
16 1.5 (DL-EQZ)
159.9089 637.07
17 0.9DL-1.5EQZ
169.9463 637.07

1030.93
846.89
1034.5
631.78
802.59
979.13
576.41
748.17
911.1
508.37
901.32
1102.54
699.81

63.26
6.71
6.06
4.67
6.94
6.21
4.62
8.25
7.35
5.72
11.98
10.88
7.87

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
20.46468
52.57635
65.46236
61.5349
44.68821
56.49973
55.95266
72.47787
91.16353
82.9604
41.06118
50.68786
58.62936

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

500
750

mm
mm

3000
3600
525
0.273

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
1112
989.3
1114.4
845.89
959.77
1077.5
808.98
923.48
1032.1
763.62
1025.6
1159.7
891.25

27.17
9.41
8.52
6.88
10.74
9.54
7.23
6.38
5.67
4.61
12.49
11.44
7.61

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 735.024 kN
Punching Shear,P =
735.024 x (( 3 x 3.6 ) - ( 1.025 x 1.275 ))
( 3 * 3.6 )
P = 646.09 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
500
750
0.667
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

1025
1275
4600

mm
mm
mm

Depth Required 646090


=
1.37 x4600
= 102.52 mm
Shear Resistance = 1.37 x 4600 x 525 / 1000
3308
kN
158.023

kN/m2

B) One Way Shear


900
0

1425

132.583

kN/m2

117.743

kN/m2

525

600

3600

750

500
200
1250
525

725

3000

150.103

kN/m2
154.723 kN/m2

158.023

kN/m2

156.109

kN/m2

56.263

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 156.109 - 25 x 0.6 - 18 x ( 2 115.909 kN/m2
-- For without
Length at critical section =
3000
mm
Width at critical section =
900
mm
Shear Force = 115.909 x 3 x 0.9
= 312.9543 kN
At Width
Maximum Pressure = 132.583 - 25 x 0.6 - 18 x ( 2 92.383 kN/m2
-- For without
Length at critical section =
3600
mm
Width at critical section =
725
mm
Shear Force = 92.383 x 3.6 x 0.725
= 241.1196 kN

0.6 )
Buoynacy Condition With Stress Increse

0.6 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 312.9543 kN


Corresponding Length =
3000
mm
% Ast =

0.273

Allowable Shear Stress =


0.3804 N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.3804 x 1
2
=
0.3804 N/mm
Depth Required = 312954.3
0.3804 x 3000
=
350
mm
Check For Depth @ Critical Section
Critical section from face of
column =
525
mm

Min. Length from column face to


edge of footing =
1250
Depth @ Edge of fdn D1 =
200
Depth @ face of column D =
600
Depth @ Critical s/c =
432
Effe. Depth @ Critical s/c =
357
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 158.023
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 162 + 262.71 ) / ( 3 x 3.6 )
39.33
118.693 kN/m2
1.425

Bending Moment = 118.693 x 1.425 x 1.425 / 2


= 120.51 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

979.4
0.2

mm2
%

1050
16

mm2
mm dia bars
mm2
mm

200.96
191
140

1-

(4.6 x Mu )
fck x b x d2

fy

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

1435.43

mm

Provide 16 mm dia Bars @ 140 mm spacing bothways

i.e.0.274%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
424.71 kN
Area Load = 424.71 / (3 x 3.6)

Maxi. Projection of fdn =

39.33

kN/m2

1.425

Bending Moment = 39.33 x 1.425 x 1.425 / 2


=
Ast =

39.93

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

318.82

Mini % of Re-bar =

0.12

Ast =
Use

630
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

179
175

mm
mm
2
Area Provided = 645.943 mm
Provide 12 mm dia Bars @ 175 mm spacing bothways

i.e.0.124%

Summary Of Design :Length Of Footing :3000 mm


WIdth Of Footing :3600 mm
Depth Of Footing :600
mm
Depth @ Edge of fdn D1 =
200
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 175 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 140 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

PAD
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
2.2
2.2
0.5
0.5
0.3
0.3
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

0.95

Wp

0.95
Z

0.95

Lp

F10

COLUMN NO.

SC1

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

0.95

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 2.2 x 2.2 x 0.5
=
60.5
kN
Buoyant Self wt. of Fdn = 0 x 2.2 x 2.2 x 0.5
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(2.2 x 2.2) - (0.3 x 0.3)] x (2 - 0.5 ) x 18


=
128.25 kN
Buoyant weight of Soil = [(2.2 x 2.2) - (0.3 x 0.3)] x (2 - 0.5 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 60.5 + 0 + 128.25


=
188.75 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
363
F10-SC1

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
2.405
263.282
6 1.2 (DL+LL+EQX)
-7.746
211.326
7 1.5 (DL+EQX)
-9.656
264.296
8 0.9DL+1.5EQX
-10.628 158.928
9 1.2 (DL+LL-EQX)
11.594
209.925
10 1.5 (DL-EQX)
14.519
262.545
11 0.9DL-1.5EQX
13.546
157.177
12 1.2 (DL+LL+EQZ)
2.812
214.607
13 1.5 (DL+EQZ)
3.542
268.396
14 0.9DL+1.5EQZ
2.569
163.028
15 1.2 (DL+LL-EQZ)
1.036
206.645
16 1.5 (DL-EQZ)
1.321
258.444
17 0.9DL-1.5EQZ
0.349
153.076

kN - m)
FORCE-Z
0.156
0.51
0.483
0.483
-0.261
-0.48
-0.48
-10.563
-13.358
-13.359
10.813
13.362
13.361

MOM-X
2.26
2.684
3.028
2.255
0.932
0.839
0.066
-21.669
-27.413
-28.186
25.285
31.28
30.507

MOM-Y
MOM Z
-0.651 -3.982
-0.835 14.105
-0.966 17.608
-0.737
19.21
-0.207 -20.476
-0.182 -25.619
0.048 -24.016
-0.815 -3.754
-0.942 -4.716
-0.712 -3.114
-0.227 -2.617
-0.206 -3.295
0.023
-1.693

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 2.2 x 2.2
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

4.84

m2

1/6 x 2.2 x 2.2 x 2.2


1.775

m3

1/6 x 2.2 x 2.2 x 2.2


1.775

m3

Total Vertical Load P = 263.282 + 188.75


= 452.032 kN

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 452.032 / (2.2 x 2.2 )


=

93.395

kN/m

Mxx/Zxx = 2.26 / 1.775


Mxx/Zxx =

1.274

kN/m

Mzz/Zzz = 3.982 / 1.775


Mzz/Zzz =

2.244

kN/m

Maxi.Soil Pressure pmax = 93.395 + 1.274 + 2.244


pmax =

96.92

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 93.395 - 1.274 - 2.244
pmin =

89.88

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
4.58
kN.m
Calculation of Stabilizing Moment
Due to External Load = 263.282 x 2.2 / 2
=
289.62 kN.m
Due to wt. of Pedestral = 0 x 1.1
=
0

kN.m

Due to Self Wt. of Fdn = 60.5 x 1.1


=
66.55
kN.m
Due to Wt. of Soil = 128.25 x 1.1
=
141.08 kN.m
Total Stabilizing moment = 289.62 + 0 + 66.55 + 141.08
=
497.25 kN.m
F.O.S. against Overturning = 497.25 / 4.58
= 108.57 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

2.42

kN

Total Vertical Load = 452.032 kN


F.O.S. against Sliding = 452.032 x 0.5 / 2.42
=
93.4
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
363 5 1.5 (DL+LL)
263.282 54.39711
F10-SC1 6 1.2 (DL+LL+EQX)
211.326 43.6624
0
7 1.5 (DL+EQX)
264.296 54.60661
0
8 0.9DL+1.5EQX
158.928 32.83636
0
9 1.2 (DL+LL-EQX)
209.925 43.37293
0
10 1.5 (DL-EQX)
262.545 54.24483
0
11 0.9DL-1.5EQX
157.177 32.47459
0
12 1.2 (DL+LL+EQZ)
214.607 44.34029
0
13 1.5 (DL+EQZ)
268.396 55.45372
0
14 0.9DL+1.5EQZ
163.028 33.68347
0
15 1.2 (DL+LL-EQZ)
206.645 42.69525
0
16 1.5 (DL-EQZ)
258.444 53.39752
0
17 0.9DL-1.5EQZ
153.076 31.62727
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

1.28
1.52
1.71
1.28
0.53
0.48
0.04
12.21
15.45
15.88
14.25
17.63
17.19

2.25
7.95
9.92
10.83
11.54
14.44
13.54
2.12
2.66
1.76
1.48
1.86
0.96

57.9271
53.1324
66.2366
44.9464
55.4429
69.1648
46.0546
58.6703
73.5637
51.3235
58.4252
72.8875
49.7773

140
166
166
166
166
166
166
166
166
166
166
166
166

50.87
34.2
42.98
20.73
31.31
39.33
18.9
30.02
37.35
16.05
26.97
33.91
13.48

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 57.92711 kN/m2
pmax = 73.56372 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
363 5 1.5 (DL+LL)
54.39711
1.28
F10-SC1 6 1.2 (DL+LL+EQX)
43.6624
1.52
0
7 1.5 (DL+EQX)
54.60661
1.71
0
8 0.9DL+1.5EQX
32.83636
1.28
0
9 1.2 (DL+LL-EQX)
43.37293
0.53
0
10 1.5 (DL-EQX)
54.24483
0.48
0
11 0.9DL-1.5EQX
32.47459
0.04
0
12 1.2 (DL+LL+EQZ)
44.34029 12.21
0
13 1.5 (DL+EQZ)
55.45372 15.45
0
14 0.9DL+1.5EQZ
33.68347 15.88
0
15 1.2 (DL+LL-EQZ)
42.69525 14.25
0
16 1.5 (DL-EQZ)
53.39752 17.63
0
17 0.9DL-1.5EQZ
31.62727 17.19
Joint

kN/m2

Mzz/Zzz
(3)
2.25
7.95
9.92
10.83
11.54
14.44
13.54
2.12
2.66
1.76
1.48
1.86
0.96

pmin =

13.48

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

57.928
53.133
66.237
44.947
55.443
69.165
46.055
58.671
73.564
51.324
58.426
72.888
49.778

55.368
50.093
62.817
42.387
54.383
68.205
45.975
34.251
42.664
19.564
29.926
37.628
15.398

50.868
34.193
42.977
20.727
31.303
39.325
18.895
30.011
37.344
16.044
26.966
33.908
13.478

53.428
37.233
46.397
23.287
32.363
40.285
18.975
54.431
68.244
47.804
55.466
69.168
47.858

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
363 5 1.5 (DL+LL)
452.032 93.39504
F10-SC1 6 1.2 (DL+LL+EQX)
400.076 82.66033
0
7 1.5 (DL+EQX)
453.046 93.60455
0
8 0.9DL+1.5EQX
347.678 71.8343
0
9 1.2 (DL+LL-EQX)
398.675 82.37087
0
10 1.5 (DL-EQX)
451.295 93.24277
0
11 0.9DL-1.5EQX
345.927 71.47252
0
12 1.2 (DL+LL+EQZ)
403.357 83.33822
0
13 1.5 (DL+EQZ)
457.146 94.45165
0
14 0.9DL+1.5EQZ
351.778 72.6814
0
15 1.2 (DL+LL-EQZ)
395.395 81.69318
0
16 1.5 (DL-EQZ)
447.194 92.39545
0
17 0.9DL-1.5EQZ
341.826 70.62521
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

1.28
1.52
1.71
1.28
0.53
0.48
0.04
12.21
15.45
15.88
14.25
17.63
17.19

2.25
7.95
9.92
10.83
11.54
14.44
13.54
2.12
2.66
1.76
1.48
1.86
0.96

96.925
92.1303
105.235
83.9443
94.4409
108.163
85.0525
97.6682
112.562
90.3214
97.4232
111.885
88.7752

140
166
166
166
166
166
166
166
166
166
166
166
166

89.87
73.2
81.98
59.73
70.31
78.33
57.9
69.01
76.35
55.05
65.97
72.91
52.48

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 96.92504 kN/m2
pmax = 112.5617 kN/m2
pmin =

89.87 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
363 5 1.5 (DL+LL)
93.39504
1.28
F10-SC1 6 1.2 (DL+LL+EQX)
82.66033
1.52
0
7 1.5 (DL+EQX)
93.60455
1.71
0
8 0.9DL+1.5EQX
71.8343
1.28
0
9 1.2 (DL+LL-EQX)
82.37087
0.53
0
10 1.5 (DL-EQX)
93.24277
0.48
0
11 0.9DL-1.5EQX
71.47252
0.04
0
12 1.2 (DL+LL+EQZ)
83.33822 12.21
0
13 1.5 (DL+EQZ)
94.45165 15.45
0
14 0.9DL+1.5EQZ
72.6814 15.88
0
15 1.2 (DL+LL-EQZ)
81.69318 14.25
0
16 1.5 (DL-EQZ)
92.39545 17.63
0
17 0.9DL-1.5EQZ
70.62521 17.19
Joint

Mzz/Zzz
(3)
2.25
7.95
9.92
10.83
11.54
14.44
13.54
2.12
2.66
1.76
1.48
1.86
0.96

pmin =

1+2+3

1-2+3

96.926 94.366
92.131 89.091
105.235 101.815
83.945 81.385
94.441 93.381
108.163 107.203
85.053 84.973
97.669 73.249
112.562 81.662
90.322 58.562
97.424 68.924
111.886 76.626
88.776 54.396

52.48

kN/m2

1-2-3

1+2-3

89.866
73.191
81.975
59.725
70.301
78.323
57.893
69.009
76.342
55.042
65.964
72.906
52.476

92.426
76.231
85.395
62.285
71.361
79.283
57.973
93.429
107.24
86.802
94.464
108.17
86.856

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
363 5 1.5 (DL+LL)
4.578638 207.63
F10-SC1 6 1.2 (DL+LL+EQX)
14.35809 207.63
0
7 1.5 (DL+EQX)
17.86646 207.63
0
8 0.9DL+1.5EQX
19.3419 207.63
0
9 1.2 (DL+LL-EQX)
20.4972 207.63
0
10 1.5 (DL-EQX)
25.63273 207.63
0
11 0.9DL-1.5EQX
24.01609 207.63
0
12 1.2 (DL+LL+EQZ)
21.99177 207.63
0
13 1.5 (DL+EQZ)
27.8157 207.63
0
14 0.9DL+1.5EQZ
28.3575 207.63
0
15 1.2 (DL+LL-EQZ)
25.42007 207.63
0
16 1.5 (DL-EQZ)
31.45307 207.63
0
17 0.9DL-1.5EQZ
30.55394 207.63

289.62
232.46
290.73
174.83
230.92
288.8
172.9
236.07
295.24
179.34
227.31
284.29
168.39

108.61
30.66
27.9
19.78
21.4
19.37
15.85
20.18
18.08
13.65
17.12
15.64
12.31

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
2.410054
7.762771
9.668072
10.63897
11.59694
14.52693
13.5545
10.93089
13.81962
13.60377
10.86252
13.42714
13.36556

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

300
300

mm
mm

2200
2200
425
0.201

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
452.03
400.08
453.05
347.68
398.68
451.3
345.93
403.36
457.15
351.78
395.4
447.19
341.83

93.79
25.77
23.44
16.34
17.19
15.54
12.77
18.46
16.54
12.93
18.2
16.66
12.79

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 268.396 kN
Punching Shear,P =
268.396 x (( 2.2 x 2.2 ) - ( 0.725 x 0.725 ))
( 2.2 * 2.2 )
P = 239.25 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
300
300
1
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

725
725
2900

mm
mm
mm

Depth Required 239250


=
1.37 x2900
= 60.22 mm
Shear Resistance = 1.37 x 2900 x 425 / 1000
1688
kN
112.562

kN/m2

B) One Way Shear


525
0

950

111.293

kN/m2

110.265

kN/m2

425

500

2200

300

300
500
950
425

525

2200

81.662

kN/m2
99.219 kN/m2

112.562

kN/m2

105.189

kN/m2

107.242

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 112.562 - 25 x 0.5 - 18 x ( 2 73.062 kN/m2
-- For without
Length at critical section =
2200
mm
Width at critical section =
525
mm
Shear Force = 73.062 x 2.2 x 0.525
= 84.38661 kN
At Width
Maximum Pressure = 112.562 - 25 x 0.5 - 18 x ( 2 73.062 kN/m2
-- For without
Length at critical section =
2200
mm
Width at critical section =
525
mm
Shear Force = 73.062 x 2.2 x 0.525
= 84.38661 kN

0.5 )
Buoynacy Condition With Stress Increse

0.5 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 84.38661 kN


Corresponding Length =
2200
mm
% Ast =

0.201

Allowable Shear Stress =


0.33
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.33 x 1
2

N/mm
=
0.33
Depth Required = 84386.61
0.33 x 2200
=
192
mm
Check For Depth @ Critical Section
Critical section from face of
column =
425
mm
Min. Length from column face to
edge of footing =
950
Depth @ Edge of fdn D1 =
500
Depth @ face of column D =
500
Depth @ Critical s/c =
500
Effe. Depth @ Critical s/c =
425
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 112.562
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 60.5 + 128.25 ) / ( 2.2 x 2.2 )
39
73.562 kN/m2
0.95

Bending Moment = 73.562 x 0.95 x 0.95 / 2


= 33.19 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

328.11
0.2
850
16
200.96
236
235

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

855.15

mm

Provide 16 mm dia Bars @ 235 mm spacing bothways

i.e.0.202%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
188.75 kN
Area Load = 188.75 / (2.2 x 2.2)
39
Maxi. Projection of fdn =

0.95

kN/m2
m

Bending Moment = 39 x 0.95 x 0.95 / 2


=
Ast =

17.6

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

173.11

Mini % of Re-bar =

0.12

Ast =
Use

510
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

221
220

mm
mm
2
Area Provided = 513.819 mm
Provide 12 mm dia Bars @ 220 mm spacing bothways

i.e.0.121%

Summary Of Design :Length Of Footing :2200 mm


WIdth Of Footing :2200 mm
Depth Of Footing :500
mm
Depth @ Edge of fdn D1 =
500
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 220 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 235 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

PAD
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
2.2
2.2
0.5
0.5
0.3
0.3
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

0.95

Wp

0.95
Z

0.95

Lp

F10

COLUMN NO.

SC2

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

0.95

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 2.2 x 2.2 x 0.5
=
60.5
kN
Buoyant Self wt. of Fdn = 0 x 2.2 x 2.2 x 0.5
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(2.2 x 2.2) - (0.3 x 0.3)] x (2 - 0.5 ) x 18


=
128.25 kN
Buoyant weight of Soil = [(2.2 x 2.2) - (0.3 x 0.3)] x (2 - 0.5 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 60.5 + 0 + 128.25


=
188.75 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
268
F10-SC2

INPUT:- INPUT STAAD SUPPORT REACTION (Unit kN - m)


LOAD
FORCE-X FORCE-Y FORCE-Z
MOM-X
MOM-Y
MOM Z
5 1.5 (DL+LL)
4.847
365.362 -3.534
-4.07
0.055
-7.044
6 1.2 (DL+LL+EQX)
-1.325
286.426 -2.674
-3.076
0.23
5.918
7 1.5 (DL+EQX)
-1.662
357.931 -3.352
-3.853
0.29
7.408
8 0.9DL+1.5EQX
-3.599
211.826 -1.935
-2.222
0.267
10.221
9 1.2 (DL+LL-EQX)
9.08
298.154 -2.98
-3.436 -0.142 -17.188
10 1.5 (DL-EQX)
11.343
372.591 -3.734
-4.303 -0.176 -21.475
11 0.9DL-1.5EQX
9.407
226.487 -2.317
-2.671 -0.198 -18.661
12 1.2 (DL+LL+EQZ)
3.127
290.986 -26.911 -46.687 0.083
-4.137
13 1.5 (DL+EQZ)
3.902
363.631 -33.648 -58.367 0.106
-5.16
14 0.9DL+1.5EQZ
1.966
217.526 -32.23 -56.736 0.083
-2.347
15 1.2 (DL+LL-EQZ)
4.629
293.594 21.257
40.175
0.005
-7.134
16 1.5 (DL-EQZ)
5.779
366.891 26.562
50.211
0.008
-8.907
17 0.9DL-1.5EQZ
3.843
220.787 27.979
51.842 -0.015 -6.093

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 2.2 x 2.2
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

4.84

m2

1/6 x 2.2 x 2.2 x 2.2


1.775

m3

1/6 x 2.2 x 2.2 x 2.2


1.775

m3

Total Vertical Load P = 365.362 + 188.75


= 554.112 kN

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 554.112 / (2.2 x 2.2 )


=

114.486

kN/m

Mxx/Zxx = 4.07 / 1.775


Mxx/Zxx =

2.293

kN/m

Mzz/Zzz = 7.044 / 1.775


Mzz/Zzz =

3.969

kN/m

Maxi.Soil Pressure pmax = 114.486 + 2.293 + 3.969


pmax =

120.75

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 114.486 - 2.293 - 3.969
pmin =

108.23

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
8.14
kN.m
Calculation of Stabilizing Moment
Due to External Load = 365.362 x 2.2 / 2
=
401.9 kN.m
Due to wt. of Pedestral = 0 x 1.1
=
0

kN.m

Due to Self Wt. of Fdn = 60.5 x 1.1


=
66.55
kN.m
Due to Wt. of Soil = 128.25 x 1.1
=
141.08 kN.m
Total Stabilizing moment = 401.9 + 0 + 66.55 + 141.08
=
609.53 kN.m
F.O.S. against Overturning = 609.53 / 8.14
= 74.8808 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

kN

Total Vertical Load = 554.112 kN


F.O.S. against Sliding = 554.112 x 0.5 / 6
= 46.18
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
268 5 1.5 (DL+LL)
365.362 75.48802
F10-SC2 6 1.2 (DL+LL+EQX)
286.426 59.17893
0
7 1.5 (DL+EQX)
357.931 73.95269
0
8 0.9DL+1.5EQX
211.826 43.7657
0
9 1.2 (DL+LL-EQX)
298.154 61.60207
0
10 1.5 (DL-EQX)
372.591 76.98161
0
11 0.9DL-1.5EQX
226.487 46.79483
0
12 1.2 (DL+LL+EQZ)
290.986 60.12107
0
13 1.5 (DL+EQZ)
363.631 75.13037
0
14 0.9DL+1.5EQZ
217.526 44.94339
0
15 1.2 (DL+LL-EQZ)
293.594 60.65992
0
16 1.5 (DL-EQZ)
366.891 75.80393
0
17 0.9DL-1.5EQZ
220.787 45.61715
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

2.3
1.74
2.18
1.26
1.94
2.43
1.51
26.31
32.89
31.97
22.64
28.29
29.21

3.97
3.34
4.18
5.76
9.69
12.1
10.52
2.34
2.91
1.33
4.02
5.02
3.44

81.758
64.2589
80.3127
50.7857
73.2321
91.5116
58.8248
88.7711
110.93
78.2434
87.3199
109.114
78.2671

140
166
166
166
166
166
166
166
166
166
166
166
166

69.22
54.1
67.6
36.75
49.98
62.46
34.77
31.48
39.34
11.65
34
42.5
12.97

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 81.75802 kN/m2
pmax = 110.9304 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
268 5 1.5 (DL+LL)
75.48802
2.3
F10-SC2 6 1.2 (DL+LL+EQX)
59.17893
1.74
0
7 1.5 (DL+EQX)
73.95269
2.18
0
8 0.9DL+1.5EQX
43.7657
1.26
0
9 1.2 (DL+LL-EQX)
61.60207
1.94
0
10 1.5 (DL-EQX)
76.98161
2.43
0
11 0.9DL-1.5EQX
46.79483
1.51
0
12 1.2 (DL+LL+EQZ)
60.12107 26.31
0
13 1.5 (DL+EQZ)
75.13037 32.89
0
14 0.9DL+1.5EQZ
44.94339 31.97
0
15 1.2 (DL+LL-EQZ)
60.65992 22.64
0
16 1.5 (DL-EQZ)
75.80393 28.29
0
17 0.9DL-1.5EQZ
45.61715 29.21
Joint

kN/m2

Mzz/Zzz
(3)
3.97
3.34
4.18
5.76
9.69
12.1
10.52
2.34
2.91
1.33
4.02
5.02
3.44

pmin =

11.65

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

81.759
64.259
80.313
50.786
73.233
91.512
58.825
88.772
110.931
78.244
87.32
109.114
78.268

77.159
60.779
75.953
48.266
69.353
86.652
55.805
36.152
45.151
14.304
42.04
52.534
19.848

69.219
54.099
67.593
36.746
49.973
62.452
34.765
31.472
39.331
11.644
34
42.494
12.968

73.819
57.579
71.953
39.266
53.853
67.312
37.785
84.092
105.11
75.584
79.28
99.074
71.388

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
268 5 1.5 (DL+LL)
554.112 114.486
F10-SC2 6 1.2 (DL+LL+EQX)
475.176 98.17686
0
7 1.5 (DL+EQX)
546.681 112.9506
0
8 0.9DL+1.5EQX
400.576 82.76364
0
9 1.2 (DL+LL-EQX)
486.904
100.6
0
10 1.5 (DL-EQX)
561.341 115.9795
0
11 0.9DL-1.5EQX
415.237 85.79277
0
12 1.2 (DL+LL+EQZ)
479.736 99.11901
0
13 1.5 (DL+EQZ)
552.381 114.1283
0
14 0.9DL+1.5EQZ
406.276 83.94132
0
15 1.2 (DL+LL-EQZ)
482.344 99.65785
0
16 1.5 (DL-EQZ)
555.641 114.8019
0
17 0.9DL-1.5EQZ
409.537 84.61508
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

2.3
1.74
2.18
1.26
1.94
2.43
1.51
26.31
32.89
31.97
22.64
28.29
29.21

3.97
3.34
4.18
5.76
9.69
12.1
10.52
2.34
2.91
1.33
4.02
5.02
3.44

120.756
103.257
119.311
89.7836
112.23
130.51
97.8228
127.769
149.928
117.241
126.318
148.112
117.265

140
166
166
166
166
166
166
166
166
166
166
166
166

108.22
93.1
106.6
75.75
88.97
101.45
73.77
70.47
78.33
50.65
73
81.5
51.97

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 120.756 kN/m2
pmax = 149.9283 kN/m2
pmin =

108.22 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
268 5 1.5 (DL+LL)
114.486
2.3
F10-SC2 6 1.2 (DL+LL+EQX)
98.17686
1.74
0
7 1.5 (DL+EQX)
112.9506
2.18
0
8 0.9DL+1.5EQX
82.76364
1.26
0
9 1.2 (DL+LL-EQX)
100.6
1.94
0
10 1.5 (DL-EQX)
115.9795
2.43
0
11 0.9DL-1.5EQX
85.79277
1.51
0
12 1.2 (DL+LL+EQZ)
99.11901 26.31
0
13 1.5 (DL+EQZ)
114.1283 32.89
0
14 0.9DL+1.5EQZ
83.94132 31.97
0
15 1.2 (DL+LL-EQZ)
99.65785 22.64
0
16 1.5 (DL-EQZ)
114.8019 28.29
0
17 0.9DL-1.5EQZ
84.61508 29.21
Joint

Mzz/Zzz
(3)
3.97
3.34
4.18
5.76
9.69
12.1
10.52
2.34
2.91
1.33
4.02
5.02
3.44

pmin =

1+2+3

1-2+3

50.65

1-2-3

kN/m2

1+2-3

120.756 116.156 108.216 112.82


103.257 99.777
93.097 96.577
119.311 114.951 106.591 110.95
89.784 87.264
75.744 78.264
112.23 108.35
88.97
92.85
130.51 125.65
101.45 106.31
97.823 94.803
73.763 76.783
127.77
75.15
70.47
123.09
149.929 84.149
78.329 144.11
117.242 53.302
50.642 114.58
126.318 81.038
72.998 118.28
148.112 91.532
81.492 138.07
117.266 58.846
51.966 110.39

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
268 5 1.5 (DL+LL)
8.135283 207.63
F10-SC2 6 1.2 (DL+LL+EQX)
6.66967 207.63
0
7 1.5 (DL+EQX)
8.350094 207.63
0
8 0.9DL+1.5EQX
10.45974 207.63
0
9 1.2 (DL+LL-EQX)
17.52808 207.63
0
10 1.5 (DL-EQX)
21.90186 207.63
0
11 0.9DL-1.5EQX
18.85118 207.63
0
12 1.2 (DL+LL+EQZ)
46.86993 207.63
0
13 1.5 (DL+EQZ)
58.59464 207.63
0
14 0.9DL+1.5EQZ
56.78452 207.63
0
15 1.2 (DL+LL-EQZ)
40.80349 207.63
0
16 1.5 (DL-EQZ)
50.99489 207.63
0
17 0.9DL-1.5EQZ
52.19883 207.63

401.9
315.07
393.73
233.01
327.97
409.86
249.14
320.09
400
239.28
322.96
403.59
242.87

74.93
78.37
72.02
42.13
30.56
28.2
24.24
11.26
10.38
7.88
13.01
11.99
8.64

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
5.998547
2.984276
3.74141
4.086199
9.556506
11.94179
9.688144
27.09207
33.87349
32.28991
21.75518
27.18339
28.24169

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

300
300

mm
mm

2200
2200
425
0.201

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
554.11
475.18
546.68
400.58
486.9
561.34
415.24
479.74
552.38
406.28
482.34
555.64
409.54

46.19
79.62
73.06
49.02
25.48
23.51
21.44
8.86
8.16
6.3
11.09
10.23
7.26

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 372.591 kN
Punching Shear,P =
372.591 x (( 2.2 x 2.2 ) - ( 0.725 x 0.725 ))
( 2.2 * 2.2 )
P = 332.13 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
300
300
1
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

725
725
2900

mm
mm
mm

Depth Required 332130


=
1.37 x2900
=
83.6
mm
Shear Resistance = 1.37 x 2900 x 425 / 1000
1688
kN
149.929

kN/m2

B) One Way Shear


525
0

950

148.541

kN/m2

147.416

kN/m2

425

500

2200

300

300
500
950
425

525

2200

84.149

kN/m2
121.524 kN/m2

149.929

kN/m2

134.232

kN/m2

144.109

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 149.929 - 25 x 0.5 - 18 x ( 2 110.429 kN/m2
-- For without
Length at critical section =
2200
mm
Width at critical section =
525
mm
Shear Force = 110.429 x 2.2 x 0.525
= 127.5455 kN
At Width
Maximum Pressure = 149.929 - 25 x 0.5 - 18 x ( 2 110.429 kN/m2
-- For without
Length at critical section =
2200
mm
Width at critical section =
525
mm
Shear Force = 110.429 x 2.2 x 0.525
= 127.5455 kN

0.5 )
Buoynacy Condition With Stress Increse

0.5 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 127.5455 kN


Corresponding Length =
2200
mm
% Ast =

0.201

Allowable Shear Stress =


0.33
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.33 x 1
2

N/mm
=
0.33
Depth Required = 127545.5
0.33 x 2200
=
251
mm
Check For Depth @ Critical Section
Critical section from face of
column =
425
mm
Min. Length from column face to
edge of footing =
950
Depth @ Edge of fdn D1 =
500
Depth @ face of column D =
500
Depth @ Critical s/c =
500
Effe. Depth @ Critical s/c =
425
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 149.929
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 60.5 + 128.25 ) / ( 2.2 x 2.2 )
39
110.929 kN/m2
0.95

Bending Moment = 110.929 x 0.95 x 0.95 / 2


= 50.06 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

497.66
0.2
850
16
200.96
236
235

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

855.15

mm

Provide 16 mm dia Bars @ 235 mm spacing bothways

i.e.0.202%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
188.75 kN
Area Load = 188.75 / (2.2 x 2.2)
39
Maxi. Projection of fdn =

0.95

kN/m2
m

Bending Moment = 39 x 0.95 x 0.95 / 2


=
Ast =

17.6

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

173.11

Mini % of Re-bar =

0.12

Ast =
Use

510
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

221
220

mm
mm
2
Area Provided = 513.819 mm
Provide 12 mm dia Bars @ 220 mm spacing bothways

i.e.0.121%

Summary Of Design :Length Of Footing :2200 mm


WIdth Of Footing :2200 mm
Depth Of Footing :500
mm
Depth @ Edge of fdn D1 =
500
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 220 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 235 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

PAD
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
2.2
2.2
0.5
0.5
0.3
0.3
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

0.95

Wp

0.95
Z

0.95

Lp

F10

COLUMN NO.

SC3

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

0.95

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 2.2 x 2.2 x 0.5
=
60.5
kN
Buoyant Self wt. of Fdn = 0 x 2.2 x 2.2 x 0.5
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(2.2 x 2.2) - (0.3 x 0.3)] x (2 - 0.5 ) x 18


=
128.25 kN
Buoyant weight of Soil = [(2.2 x 2.2) - (0.3 x 0.3)] x (2 - 0.5 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 60.5 + 0 + 128.25


=
188.75 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
364
F10-SC3

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-6.667
202.308
6 1.2 (DL+LL+EQX)
-12.971 164.526
7 1.5 (DL+EQX)
-16.218 205.658
8 0.9DL+1.5EQX
-13.549 124.735
9 1.2 (DL+LL-EQX)
2.303
159.167
10 1.5 (DL-EQX)
2.875
198.959
11 0.9DL-1.5EQX
5.543
118.035
12 1.2 (DL+LL+EQZ)
-6.198
162.152
13 1.5 (DL+EQZ)
-7.752
202.69
14 0.9DL+1.5EQZ
-5.083
121.767
15 1.2 (DL+LL-EQZ)
-4.469
161.541
16 1.5 (DL-EQZ)
-5.591
201.927
17 0.9DL-1.5EQZ
-2.922
121.004

kN - m)
FORCE-Z
-4.91
-3.748
-4.281
-2.479
-4.108
-4.73
-2.928
-15.829
-19.381
-17.579
7.973
10.37
12.173

MOM-X
-10.778
-8.234
-9.296
-5.383
-9.011
-10.267
-6.354
-38.582
-47.23
-43.318
21.336
27.667
31.58

MOM-Y
1.316
1.007
1.123
0.651
1.098
1.237
0.765
1.206
1.372
0.9
0.899
0.988
0.516

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 2.2 x 2.2
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

4.84

m2

1/6 x 2.2 x 2.2 x 2.2


1.775

m3

1/6 x 2.2 x 2.2 x 2.2


1.775

m3

Total Vertical Load P = 202.308 + 188.75


= 391.058 kN

MOM Z
6.233
19.344
24.187
21.691
-9.371
-11.706
-14.202
6.613
8.274
5.778
3.359
4.207
1.711

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 391.058 / (2.2 x 2.2 )


=

80.797

kN/m

Mxx/Zxx = 10.778 / 1.775


Mxx/Zxx =

6.073

kN/m

Mzz/Zzz = 6.233 / 1.775


Mzz/Zzz =

3.512

kN/m

Maxi.Soil Pressure pmax = 80.797 + 6.073 + 3.512


pmax =

90.39

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 80.797 - 6.073 - 3.512
pmin =

71.22

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
12.46
kN.m
Calculation of Stabilizing Moment
Due to External Load = 202.308 x 2.2 / 2
=
222.54 kN.m
Due to wt. of Pedestral = 0 x 1.1
=
0

kN.m

Due to Self Wt. of Fdn = 60.5 x 1.1


=
66.55
kN.m
Due to Wt. of Soil = 128.25 x 1.1
=
141.08 kN.m
Total Stabilizing moment = 222.54 + 0 + 66.55 + 141.08
=
430.17 kN.m
F.O.S. against Overturning = 430.17 / 12.46
= 34.5241 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

8.28

kN

Total Vertical Load = 391.058 kN


F.O.S. against Sliding = 391.058 x 0.5 / 8.28
= 23.62
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
364 5 1.5 (DL+LL)
202.308 41.79917
F10-SC3 6 1.2 (DL+LL+EQX)
164.526 33.99298
0
7 1.5 (DL+EQX)
205.658 42.49132
0
8 0.9DL+1.5EQX
124.735 25.77169
0
9 1.2 (DL+LL-EQX)
159.167 32.88574
0
10 1.5 (DL-EQX)
198.959 41.10723
0
11 0.9DL-1.5EQX
118.035 24.3874
0
12 1.2 (DL+LL+EQZ)
162.152 33.50248
0
13 1.5 (DL+EQZ)
202.69 41.8781
0
14 0.9DL+1.5EQZ
121.767 25.15847
0
15 1.2 (DL+LL-EQZ)
161.541 33.37624
0
16 1.5 (DL-EQZ)
201.927 41.72045
0
17 0.9DL-1.5EQZ
121.004 25.00083
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

6.08
4.64
5.24
3.04
5.08
5.79
3.58
21.74
26.61
24.41
12.03
15.59
17.8

3.52
10.9
13.63
12.23
5.28
6.6
8.01
3.73
4.67
3.26
1.9
2.38
0.97

51.3992
49.533
61.3613
41.0417
43.2457
53.4972
35.9774
58.9725
73.1581
52.8285
47.3062
59.6905
43.7708

140
166
166
166
166
166
166
166
166
166
166
166
166

32.2
18.46
23.63
10.51
22.53
28.72
12.8
8.04
10.6
-2.52
19.45
23.76
6.24

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 51.39917 kN/m2
pmax = 73.1581 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
364 5 1.5 (DL+LL)
41.79917
6.08
F10-SC3 6 1.2 (DL+LL+EQX)
33.99298
4.64
0
7 1.5 (DL+EQX)
42.49132
5.24
0
8 0.9DL+1.5EQX
25.77169
3.04
0
9 1.2 (DL+LL-EQX)
32.88574
5.08
0
10 1.5 (DL-EQX)
41.10723
5.79
0
11 0.9DL-1.5EQX
24.3874
3.58
0
12 1.2 (DL+LL+EQZ)
33.50248 21.74
0
13 1.5 (DL+EQZ)
41.8781 26.61
0
14 0.9DL+1.5EQZ
25.15847 24.41
0
15 1.2 (DL+LL-EQZ)
33.37624 12.03
0
16 1.5 (DL-EQZ)
41.72045 15.59
0
17 0.9DL-1.5EQZ
25.00083
17.8
Joint

kN/m2

Mzz/Zzz
(3)
3.52
10.9
13.63
12.23
5.28
6.6
8.01
3.73
4.67
3.26
1.9
2.38
0.97

pmin =

-2.52

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

51.4
49.533
61.362
41.042
43.246
53.498
35.978
58.973
73.159
52.829
47.307
59.691
43.771

39.24
40.253
50.882
34.962
33.086
41.918
28.818
15.493
19.939
4.009
23.247
28.511
8.171

32.2
18.453
23.622
10.502
22.526
28.718
12.798
8.033
10.599
-2.512
19.447
23.751
6.231

44.36
27.733
34.102
16.582
32.686
40.298
19.958
51.513
63.819
46.309
43.507
54.931
41.831

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
364 5 1.5 (DL+LL)
391.058 80.79711
F10-SC3 6 1.2 (DL+LL+EQX)
353.276 72.99091
0
7 1.5 (DL+EQX)
394.408 81.48926
0
8 0.9DL+1.5EQX
313.485 64.76963
0
9 1.2 (DL+LL-EQX)
347.917 71.88368
0
10 1.5 (DL-EQX)
387.709 80.10517
0
11 0.9DL-1.5EQX
306.785 63.38533
0
12 1.2 (DL+LL+EQZ)
350.902 72.50041
0
13 1.5 (DL+EQZ)
391.44 80.87603
0
14 0.9DL+1.5EQZ
310.517 64.1564
0
15 1.2 (DL+LL-EQZ)
350.291 72.37417
0
16 1.5 (DL-EQZ)
390.677 80.71839
0
17 0.9DL-1.5EQZ
309.754 63.99876
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

6.08
4.64
5.24
3.04
5.08
5.79
3.58
21.74
26.61
24.41
12.03
15.59
17.8

3.52
10.9
13.63
12.23
5.28
6.6
8.01
3.73
4.67
3.26
1.9
2.38
0.97

90.3971
88.5309
100.359
80.0396
82.2437
92.4952
74.9753
97.9704
112.156
91.8264
86.3042
98.6884
82.7688

140
166
166
166
166
166
166
166
166
166
166
166
166

71.2
57.46
62.62
49.5
61.53
67.72
51.8
47.04
49.6
36.49
58.45
62.75
45.23

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 90.39711 kN/m2
pmax = 112.156 kN/m2
pmin =

71.2 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
364 5 1.5 (DL+LL)
80.79711
6.08
F10-SC3 6 1.2 (DL+LL+EQX)
72.99091
4.64
0
7 1.5 (DL+EQX)
81.48926
5.24
0
8 0.9DL+1.5EQX
64.76963
3.04
0
9 1.2 (DL+LL-EQX)
71.88368
5.08
0
10 1.5 (DL-EQX)
80.10517
5.79
0
11 0.9DL-1.5EQX
63.38533
3.58
0
12 1.2 (DL+LL+EQZ)
72.50041 21.74
0
13 1.5 (DL+EQZ)
80.87603 26.61
0
14 0.9DL+1.5EQZ
64.1564 24.41
0
15 1.2 (DL+LL-EQZ)
72.37417 12.03
0
16 1.5 (DL-EQZ)
80.71839 15.59
0
17 0.9DL-1.5EQZ
63.99876
17.8
Joint

Mzz/Zzz
(3)
3.52
10.9
13.63
12.23
5.28
6.6
8.01
3.73
4.67
3.26
1.9
2.38
0.97

pmin =

36.49

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

90.398
88.531
100.36
80.04
82.244
92.496
74.976
97.971
112.157
91.827
86.305
98.689
82.769

78.238
79.251
89.88
73.96
72.084
80.916
67.816
54.491
58.937
43.007
62.245
67.509
47.169

71.198
57.451
62.62
49.5
61.524
67.716
51.796
47.031
49.597
36.487
58.445
62.749
45.229

83.358
66.731
73.1
55.58
71.684
79.296
58.956
90.511
102.82
85.307
82.505
93.929
80.829

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
364 5 1.5 (DL+LL)
12.45053 207.63
F10-SC3 6 1.2 (DL+LL+EQX)
21.02354 207.63
0
7 1.5 (DL+EQX)
25.9119 207.63
0
8 0.9DL+1.5EQX
22.34896 207.63
0
9 1.2 (DL+LL-EQX)
13.00053 207.63
0
10 1.5 (DL-EQX)
15.57054 207.63
0
11 0.9DL-1.5EQX
15.5586 207.63
0
12 1.2 (DL+LL+EQZ)
39.14464 207.63
0
13 1.5 (DL+EQZ)
47.94926 207.63
0
14 0.9DL+1.5EQZ
43.70165 207.63
0
15 1.2 (DL+LL-EQZ)
21.59879 207.63
0
16 1.5 (DL-EQZ)
27.98503 207.63
0
17 0.9DL-1.5EQZ
31.62632 207.63

222.54
180.98
226.23
137.21
175.09
218.86
129.84
178.37
222.96
133.95
177.7
222.12
133.11

34.56
18.49
16.75
15.43
29.44
27.4
21.7
9.87
8.99
7.82
17.85
15.36
10.78

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
8.279915
13.50164
16.77351
13.77392
4.709509
5.535208
6.268814
16.99919
20.87383
18.29913
9.14006
11.78118
12.51879

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

300
300

mm
mm

2200
2200
425
0.201

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
391.06
353.28
394.41
313.49
347.92
387.71
306.79
350.9
391.44
310.52
350.29
390.68
309.75

23.62
13.09
11.76
11.38
36.94
35.03
24.47
10.33
9.38
8.49
19.17
16.59
12.38

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 205.658 kN
Punching Shear,P =
205.658 x (( 2.2 x 2.2 ) - ( 0.725 x 0.725 ))
( 2.2 * 2.2 )
P = 183.33 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
300
300
1
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

725
725
2900

mm
mm
mm

Depth Required 183330


=
1.37 x2900
= 46.14 mm
Shear Resistance = 1.37 x 2900 x 425 / 1000
1688
kN
112.157

kN/m2

B) One Way Shear


525
0

950

109.929

kN/m2

108.124

kN/m2

425

500

2200

300

300
500
950
425

525

2200

58.937

kN/m2
89.176 kN/m2

112.157

kN/m2

99.457

kN/m2

102.817

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 112.157 - 25 x 0.5 - 18 x ( 2 72.657 kN/m2
-- For without
Length at critical section =
2200
mm
Width at critical section =
525
mm
Shear Force = 72.657 x 2.2 x 0.525
= 83.91884 kN
At Width
Maximum Pressure = 112.157 - 25 x 0.5 - 18 x ( 2 72.657 kN/m2
-- For without
Length at critical section =
2200
mm
Width at critical section =
525
mm
Shear Force = 72.657 x 2.2 x 0.525
= 83.91884 kN

0.5 )
Buoynacy Condition With Stress Increse

0.5 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 83.918835 kN


Corresponding Length =
2200
mm
% Ast =

0.201

Allowable Shear Stress =


0.33
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.33 x 1
2

N/mm
=
0.33
Depth Required = 83918.835
0.33 x 2200
=
191
mm
Check For Depth @ Critical Section
Critical section from face of
column =
425
mm
Min. Length from column face to
edge of footing =
950
Depth @ Edge of fdn D1 =
500
Depth @ face of column D =
500
Depth @ Critical s/c =
500
Effe. Depth @ Critical s/c =
425
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 112.157
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 60.5 + 128.25 ) / ( 2.2 x 2.2 )
39
73.157 kN/m2
0.95

Bending Moment = 73.157 x 0.95 x 0.95 / 2


= 33.01 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

326.31
0.2
850
16
200.96
236
235

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

855.15

mm

Provide 16 mm dia Bars @ 235 mm spacing bothways

i.e.0.202%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
188.75 kN
Area Load = 188.75 / (2.2 x 2.2)
39
Maxi. Projection of fdn =

0.95

kN/m2
m

Bending Moment = 39 x 0.95 x 0.95 / 2


=
Ast =

17.6

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

173.11

Mini % of Re-bar =

0.12

Ast =
Use

510
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

221
220

mm
mm
2
Area Provided = 513.819 mm
Provide 12 mm dia Bars @ 220 mm spacing bothways

i.e.0.121%

Summary Of Design :Length Of Footing :2200 mm


WIdth Of Footing :2200 mm
Depth Of Footing :500
mm
Depth @ Edge of fdn D1 =
500
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 220 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 235 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

PAD
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
2.2
2.2
0.5
0.5
0.3
0.3
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

0.95

Wp

0.95
Z

0.95

Lp

F10

COLUMN NO.

SC4

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

0.95

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 2.2 x 2.2 x 0.5
=
60.5
kN
Buoyant Self wt. of Fdn = 0 x 2.2 x 2.2 x 0.5
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(2.2 x 2.2) - (0.3 x 0.3)] x (2 - 0.5 ) x 18


=
128.25 kN
Buoyant weight of Soil = [(2.2 x 2.2) - (0.3 x 0.3)] x (2 - 0.5 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 60.5 + 0 + 128.25


=
188.75 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
368
F10-SC4

INPUT:- INPUT STAAD SUPPORT REACTION (Unit kN - m)


LOAD
FORCE-X FORCE-Y FORCE-Z
MOM-X
5 1.5 (DL+LL)
-1.72
128.298 1.503
5.259
6 1.2 (DL+LL+EQX)
-4.874
104.346 1.175
4.113
7 1.5 (DL+EQX)
-6.027
131.41
1.227
4.296
8 0.9DL+1.5EQX
-5.365
79.7
0.723
2.53
9 1.2 (DL+LL-EQX)
2.121
100.93
1.229
4.301
10 1.5 (DL-EQX)
2.717
127.14
1.294
4.53
11 0.9DL-1.5EQX
3.379
75.43
0.79
2.765
12 1.2 (DL+LL+EQZ)
-0.406
138.317 -4.593 -16.074
13 1.5 (DL+EQZ)
-0.442
173.874 -5.982 -20.939
14 0.9DL+1.5EQZ
0.22
122.164 -6.487 -22.704
15 1.2 (DL+LL-EQZ)
-2.346
66.959
6.997
24.488
16 1.5 (DL-EQZ)
-2.868
84.676
8.504
29.765
17 0.9DL-1.5EQZ
-2.206
32.966
8
27.999

MOM-Y
0
0
0
0
0
0
0
0
0
0
0
0
0

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 2.2 x 2.2
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

4.84

m2

1/6 x 2.2 x 2.2 x 2.2


1.775

m3

1/6 x 2.2 x 2.2 x 2.2


1.775

m3

Total Vertical Load P = 128.298 + 188.75


= 317.048 kN

MOM Z
-0.316
7.504
9.277
9.444
-8.01
-10.116
-9.948
-1.004
-1.359
-1.191
0.498
0.519
0.687

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 317.048 / (2.2 x 2.2 )


=

65.506

kN/m

Mxx/Zxx = 5.259 / 1.775


Mxx/Zxx =

2.963

kN/m

Mzz/Zzz = 0.316 / 1.775


Mzz/Zzz =

0.179

kN/m

Maxi.Soil Pressure pmax = 65.506 + 2.963 + 0.179


pmax =

68.65

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 65.506 - 2.963 - 0.179
pmin =

62.37

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
5.27
kN.m
Calculation of Stabilizing Moment
Due to External Load = 128.298 x 2.2 / 2
=
141.13 kN.m
Due to wt. of Pedestral = 0 x 1.1
=
0

kN.m

Due to Self Wt. of Fdn = 60.5 x 1.1


=
66.55
kN.m
Due to Wt. of Soil = 128.25 x 1.1
=
141.08 kN.m
Total Stabilizing moment = 141.13 + 0 + 66.55 + 141.08
=
348.76 kN.m
F.O.S. against Overturning = 348.76 / 5.27
= 66.1784 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

2.29

kN

Total Vertical Load = 317.048 kN


F.O.S. against Sliding = 317.048 x 0.5 / 2.29
= 69.23
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
368 5 1.5 (DL+LL)
128.298 26.50785
F10-SC4 6 1.2 (DL+LL+EQX)
104.346 21.55909
0
7 1.5 (DL+EQX)
131.41 27.15083
0
8 0.9DL+1.5EQX
79.7
16.46694
0
9 1.2 (DL+LL-EQX)
100.93 20.85331
0
10 1.5 (DL-EQX)
127.14 26.2686
0
11 0.9DL-1.5EQX
75.43 15.58471
0
12 1.2 (DL+LL+EQZ)
138.317 28.57789
0
13 1.5 (DL+EQZ)
173.874 35.92438
0
14 0.9DL+1.5EQZ
122.164 25.2405
0
15 1.2 (DL+LL-EQZ)
66.959 13.8345
0
16 1.5 (DL-EQZ)
84.676 17.49504
0
17 0.9DL-1.5EQZ
32.966 6.811157
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

2.97
2.32
2.43
1.43
2.43
2.56
1.56
9.06
11.8
12.8
13.8
16.77
15.78

0.18
4.23
5.23
5.33
4.52
5.7
5.61
0.57
0.77
0.68
0.29
0.3
0.39

29.6579
28.1091
34.8108
23.2269
27.8033
34.5286
22.7547
38.2079
48.4944
38.7205
27.9245
34.565
22.9812

140
166
166
166
166
166
166
166
166
166
166
166
166

23.36
15.01
19.5
9.71
13.91
18.01
8.42
18.95
23.36
11.77
-0.26
0.43
-9.36

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 29.65785 kN/m2
pmax = 48.49438 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
368 5 1.5 (DL+LL)
26.50785
2.97
F10-SC4 6 1.2 (DL+LL+EQX)
21.55909
2.32
0
7 1.5 (DL+EQX)
27.15083
2.43
0
8 0.9DL+1.5EQX
16.46694
1.43
0
9 1.2 (DL+LL-EQX)
20.85331
2.43
0
10 1.5 (DL-EQX)
26.2686
2.56
0
11 0.9DL-1.5EQX
15.58471
1.56
0
12 1.2 (DL+LL+EQZ)
28.57789
9.06
0
13 1.5 (DL+EQZ)
35.92438
11.8
0
14 0.9DL+1.5EQZ
25.2405
12.8
0
15 1.2 (DL+LL-EQZ)
13.8345
13.8
0
16 1.5 (DL-EQZ)
17.49504 16.77
0
17 0.9DL-1.5EQZ
6.811157 15.78
Joint

kN/m2

Mzz/Zzz
(3)
0.18
4.23
5.23
5.33
4.52
5.7
5.61
0.57
0.77
0.68
0.29
0.3
0.39

pmin =

-9.36

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

29.658
28.11
34.811
23.227
27.804
34.529
22.755
38.208
48.495
38.721
27.925
34.566
22.982

23.718
23.47
29.951
20.367
22.944
29.409
19.635
20.088
24.895
13.121
0.325
1.026
-8.579

23.358
15.01
19.491
9.707
13.904
18.009
8.415
18.948
23.355
11.761
-0.256
0.426
-9.359

29.298
19.65
24.351
12.567
18.764
23.129
11.535
37.068
46.955
37.361
27.345
33.966
22.202

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
368 5 1.5 (DL+LL)
317.048 65.50579
F10-SC4 6 1.2 (DL+LL+EQX)
293.096 60.55702
0
7 1.5 (DL+EQX)
320.16 66.14876
0
8 0.9DL+1.5EQX
268.45 55.46488
0
9 1.2 (DL+LL-EQX)
289.68 59.85124
0
10 1.5 (DL-EQX)
315.89 65.26653
0
11 0.9DL-1.5EQX
264.18 54.58264
0
12 1.2 (DL+LL+EQZ)
327.067 67.57583
0
13 1.5 (DL+EQZ)
362.624 74.92231
0
14 0.9DL+1.5EQZ
310.914 64.23843
0
15 1.2 (DL+LL-EQZ)
255.709 52.83244
0
16 1.5 (DL-EQZ)
273.426 56.49298
0
17 0.9DL-1.5EQZ
221.716 45.80909
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

2.97
2.32
2.43
1.43
2.43
2.56
1.56
9.06
11.8
12.8
13.8
16.77
15.78

0.18
4.23
5.23
5.33
4.52
5.7
5.61
0.57
0.77
0.68
0.29
0.3
0.39

68.6558
67.107
73.8088
62.2249
66.8012
73.5265
61.7526
77.2058
87.4923
77.7184
66.9224
73.563
61.9791

140
166
166
166
166
166
166
166
166
166
166
166
166

62.36
54.01
58.49
48.71
52.91
57.01
47.42
57.95
62.36
50.76
38.75
39.43
29.64

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 68.65579 kN/m2
pmax = 87.49231 kN/m2
pmin =

62.36 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
368 5 1.5 (DL+LL)
65.50579
2.97
F10-SC4 6 1.2 (DL+LL+EQX)
60.55702
2.32
0
7 1.5 (DL+EQX)
66.14876
2.43
0
8 0.9DL+1.5EQX
55.46488
1.43
0
9 1.2 (DL+LL-EQX)
59.85124
2.43
0
10 1.5 (DL-EQX)
65.26653
2.56
0
11 0.9DL-1.5EQX
54.58264
1.56
0
12 1.2 (DL+LL+EQZ)
67.57583
9.06
0
13 1.5 (DL+EQZ)
74.92231
11.8
0
14 0.9DL+1.5EQZ
64.23843
12.8
0
15 1.2 (DL+LL-EQZ)
52.83244
13.8
0
16 1.5 (DL-EQZ)
56.49298 16.77
0
17 0.9DL-1.5EQZ
45.80909 15.78
Joint

Mzz/Zzz
(3)
0.18
4.23
5.23
5.33
4.52
5.7
5.61
0.57
0.77
0.68
0.29
0.3
0.39

pmin =

29.64

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

68.656
67.108
73.809
62.225
66.802
73.527
61.753
77.206
87.493
77.719
66.923
73.563
61.98

62.716
62.468
68.949
59.365
61.942
68.407
58.633
59.086
63.893
52.119
39.323
40.023
30.42

62.356
54.008
58.489
48.705
52.902
57.007
47.413
57.946
62.353
50.759
38.743
39.423
29.64

68.296
58.648
63.349
51.565
57.762
62.127
50.533
76.066
85.953
76.359
66.343
72.963
61.2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
368 5 1.5 (DL+LL)
5.268485 207.63
F10-SC4 6 1.2 (DL+LL+EQX)
8.557265 207.63
0
7 1.5 (DL+EQX)
10.22342 207.63
0
8 0.9DL+1.5EQX
9.777016 207.63
0
9 1.2 (DL+LL-EQX)
9.091683 207.63
0
10 1.5 (DL-EQX)
11.08397 207.63
0
11 0.9DL-1.5EQX
10.32511 207.63
0
12 1.2 (DL+LL+EQZ)
16.10532 207.63
0
13 1.5 (DL+EQZ)
20.98306 207.63
0
14 0.9DL+1.5EQZ
22.73522 207.63
0
15 1.2 (DL+LL-EQZ)
24.49306 207.63
0
16 1.5 (DL-EQZ)
29.76952 207.63
0
17 0.9DL-1.5EQZ
28.00743 207.63

141.13
114.79
144.56
87.67
111.03
139.86
82.98
152.15
191.27
134.39
73.66
93.15
36.27

66.2
37.68
34.45
30.21
35.05
31.36
28.15
22.34
19.02
15.05
11.49
10.11
8.71

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
2.284165
5.013632
6.150631
5.413497
2.451343
3.009406
3.470121
4.610909
5.998307
6.490729
7.379819
8.9746
8.29858

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

300
300

mm
mm

2200
2200
425
0.201

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
317.05
293.1
320.16
268.45
289.68
315.89
264.18
327.07
362.62
310.91
255.71
273.43
221.72

69.41
29.23
26.03
24.8
59.09
52.49
38.07
35.47
30.23
23.96
17.33
15.24
13.36

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 173.874 kN
Punching Shear,P =
173.874 x (( 2.2 x 2.2 ) - ( 0.725 x 0.725 ))
( 2.2 * 2.2 )
P =
155
kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
300
300
1
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

725
725
2900

mm
mm
mm

Depth Required 155000


=
1.37 x2900
= 39.01 mm
Shear Resistance = 1.37 x 2900 x 425 / 1000
1688
kN
87.493

kN/m2

B) One Way Shear


525
0

950

87.126

kN/m2

86.828

kN/m2

425

500

2200

300

300
500
950
425

525

2200

63.893

kN/m2
77.303 kN/m2

87.493

kN/m2

81.862

kN/m2

85.953

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 87.493 47.993
Length at critical section =
Width at critical section =
Shear Force = 47.993 x
= 55.43192
At Width
Maximum Pressure = 87.493 47.993
Length at critical section =
Width at critical section =
Shear Force = 47.993 x
= 55.43192

25 x 0.5 - 18 x ( 2 - 0.5 )
kN/m2
-- For without Buoynacy Condition With Stress Increse
2200
mm
525
mm
2.2 x 0.525
kN
25 x 0.5 - 18 x ( 2 - 0.5 )
kN/m2
-- For without Buoynacy Condition With Stress Increse
2200
mm
525
mm
2.2 x 0.525
kN

Designed Shear Strength = 55.431915 kN


Corresponding Length =
2200
mm
% Ast =

0.201

Allowable Shear Stress =


0.33
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.33 x 1
2

N/mm
=
0.33
Depth Required = 55431.915
0.33 x 2200
=
152
mm
Check For Depth @ Critical Section
Critical section from face of
column =
425
mm
Min. Length from column face to
edge of footing =
950
Depth @ Edge of fdn D1 =
500
Depth @ face of column D =
500
Depth @ Critical s/c =
500
Effe. Depth @ Critical s/c =
425
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure =
87.493
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 60.5 + 128.25 ) / ( 2.2 x 2.2 )
39
48.493 kN/m2
0.95

Bending Moment = 48.493 x 0.95 x 0.95 / 2


= 21.88 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

215.5
0.2
850
16
200.96
236
235

1-

(4.6 x Mu )
fck x b x d2

fy
Ast =
Mini.% of re-bar =

SAG

mm2
%
mm2
mm dia bars
mm2
mm

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

855.15

mm

Provide 16 mm dia Bars @ 235 mm spacing bothways

i.e.0.202%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
188.75 kN
Area Load = 188.75 / (2.2 x 2.2)
39
Maxi. Projection of fdn =

0.95

kN/m2
m

Bending Moment = 39 x 0.95 x 0.95 / 2


=
Ast =

17.6

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

173.11

Mini % of Re-bar =

0.12

Ast =
Use

510
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

221
220

mm
mm
2
Area Provided = 513.819 mm
Provide 12 mm dia Bars @ 220 mm spacing bothways

i.e.0.121%

Summary Of Design :Length Of Footing :2200 mm


WIdth Of Footing :2200 mm
Depth Of Footing :500
mm
Depth @ Edge of fdn D1 =
500
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 220 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 235 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

PAD
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
2
3
0.5
0.5
0.3
0.3
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.35

Wp

1.35
Z

0.85

Lp

F9

COLUMN NO.

SC5

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

0.85

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 2 x 3 x 0.5


=
75
kN
Buoyant Self wt. of Fdn = 0 x 2 x 3 x 0.5
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(2 x 3) - (0.3 x 0.3)] x (2 - 0.5 ) x 18


=
159.57 kN
Buoyant weight of Soil = [(2 x 3) - (0.3 x 0.3)] x (2 - 0.5 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 75 + 0 + 159.57


=
234.57 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
262
F9-SC5

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
-13.055 424.823
6 1.2 (DL+LL+EQX)
-27.404 342.414
7 1.5 (DL+EQX)
-34.243 428.362
8 0.9DL+1.5EQX
-29.026 258.295
9 1.2 (DL+LL-EQX)
6.517
337.302
10 1.5 (DL-EQX)
8.158
421.972
11 0.9DL-1.5EQX
13.375
251.905
12 1.2 (DL+LL+EQZ)
-10.9
333.803
13 1.5 (DL+EQZ)
-13.613 417.597
14 0.9DL+1.5EQZ
-8.396
247.53
15 1.2 (DL+LL-EQZ)
-9.988
345.914
16 1.5 (DL-EQZ)
-12.473 432.737
17 0.9DL-1.5EQZ
-7.255
262.67

kN - m)
FORCE-Z
-7.985
-6.434
-8.105
-4.886
-6.342
-7.99
-4.771
-23.616
-29.582
-26.363
10.84
13.488
16.707

MOM-X
MOM-Y
MOM Z
-9.759
0.174
14.253
-7.851
0.625
43.032
-9.92
0.761
53.773
-5.974
0.7
48.079
-7.763 -0.346 -20.228
-9.81
-0.454 -25.302
-5.864 -0.515 -30.996
-37.437 0.209
12.258
-46.902 0.241
15.304
-42.956 0.179
9.61
21.823
0.07
10.547
27.173
0.067
13.166
31.118
0.005
7.472

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 2 x 3
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

m2

1/6 x 2 x 3 x 3
3

m3

1/6 x 3 x 2 x 2
2

m3

Total Vertical Load P = 424.823 + 234.57


= 659.393 kN

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 659.393 / (2 x 3 )
=

109.899

kN/m

Mxx/Zxx = 9.759 / 3
Mxx/Zxx =

3.253

kN/m

Mzz/Zzz = 14.253 / 2
Mzz/Zzz =

7.127

kN/m

Maxi.Soil Pressure pmax = 109.899 + 3.253 + 7.127


pmax =

120.28

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 109.899 - 3.253 - 7.127
pmin =

99.52

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
17.28
kN.m
Calculation of Stabilizing Moment
Due to External Load = 424.823 x 2 / 2
=
424.83 kN.m
Due to wt. of Pedestral = 0 x 1
=
0
Due to Self Wt. of Fdn = 75 x 1
=
75

kN.m

kN.m

Due to Wt. of Soil = 159.57 x 1


=
159.57 kN.m
Total Stabilizing moment = 424.83 + 0 + 75 + 159.57
=
659.4 kN.m
F.O.S. against Overturning = 659.4 / 17.28
= 38.1597 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

15.31

kN

Total Vertical Load = 659.393 kN


F.O.S. against Sliding = 659.393 x 0.5 / 15.31
= 21.54
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
262 5 1.5 (DL+LL)
424.823 70.80383
F9-SC5 6 1.2 (DL+LL+EQX)
342.414 57.069
0
7 1.5 (DL+EQX)
428.362 71.39367
0
8 0.9DL+1.5EQX
258.295 43.04917
0
9 1.2 (DL+LL-EQX)
337.302 56.217
0
10 1.5 (DL-EQX)
421.972 70.32867
0
11 0.9DL-1.5EQX
251.905 41.98417
0
12 1.2 (DL+LL+EQZ)
333.803 55.63383
0
13 1.5 (DL+EQZ)
417.597 69.5995
0
14 0.9DL+1.5EQZ
247.53
41.255
0
15 1.2 (DL+LL-EQZ)
345.914 57.65233
0
16 1.5 (DL-EQZ)
432.737 72.12283
0
17 0.9DL-1.5EQZ
262.67 43.77833
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

3.26
2.62
3.31
2
2.59
3.27
1.96
12.48
15.64
14.32
7.28
9.06
10.38

7.13
21.52
26.89
24.04
10.12
12.66
15.5
6.13
7.66
4.81
5.28
6.59
3.74

81.1938
81.209
101.594
69.0892
68.927
86.2587
59.4442
74.2438
92.8995
60.385
70.2123
87.7728
57.8983

140
166
166
166
166
166
166
166
166
166
166
166
166

60.42
32.93
41.2
17.01
43.51
54.4
24.53
37.03
46.3
22.13
45.1
56.48
29.66

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 81.19383 kN/m2
pmax = 101.5937 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
262 5 1.5 (DL+LL)
70.80383
3.26
F9-SC5 6 1.2 (DL+LL+EQX)
57.069
2.62
0
7 1.5 (DL+EQX)
71.39367
3.31
0
8 0.9DL+1.5EQX
43.04917
2
0
9 1.2 (DL+LL-EQX)
56.217
2.59
0
10 1.5 (DL-EQX)
70.32867
3.27
0
11 0.9DL-1.5EQX
41.98417
1.96
0
12 1.2 (DL+LL+EQZ)
55.63383 12.48
0
13 1.5 (DL+EQZ)
69.5995 15.64
0
14 0.9DL+1.5EQZ
41.255 14.32
0
15 1.2 (DL+LL-EQZ)
57.65233
7.28
0
16 1.5 (DL-EQZ)
72.12283
9.06
0
17 0.9DL-1.5EQZ
43.77833 10.38
Joint

kN/m2

Mzz/Zzz
(3)
7.13
21.52
26.89
24.04
10.12
12.66
15.5
6.13
7.66
4.81
5.28
6.59
3.74

pmin =

17.01

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

81.194
81.209
101.594
69.09
68.927
86.259
59.445
74.244
92.9
60.385
70.213
87.773
57.899

74.674
75.969
94.974
65.09
63.747
79.719
55.525
49.284
61.62
31.745
55.653
69.653
37.139

60.414
32.929
41.194
17.01
43.507
54.399
24.525
37.024
46.3
22.125
45.093
56.473
29.659

66.934
38.169
47.814
21.01
48.687
60.939
28.445
61.984
77.58
50.765
59.653
74.593
50.419

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
262 5 1.5 (DL+LL)
659.393 109.8988
F9-SC5 6 1.2 (DL+LL+EQX)
576.984 96.164
0
7 1.5 (DL+EQX)
662.932 110.4887
0
8 0.9DL+1.5EQX
492.865 82.14417
0
9 1.2 (DL+LL-EQX)
571.872 95.312
0
10 1.5 (DL-EQX)
656.542 109.4237
0
11 0.9DL-1.5EQX
486.475 81.07917
0
12 1.2 (DL+LL+EQZ)
568.373 94.72883
0
13 1.5 (DL+EQZ)
652.167 108.6945
0
14 0.9DL+1.5EQZ
482.1
80.35
0
15 1.2 (DL+LL-EQZ)
580.484 96.74733
0
16 1.5 (DL-EQZ)
667.307 111.2178
0
17 0.9DL-1.5EQZ
497.24 82.87333
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

3.26
2.62
3.31
2
2.59
3.27
1.96
12.48
15.64
14.32
7.28
9.06
10.38

7.13
21.52
26.89
24.04
10.12
12.66
15.5
6.13
7.66
4.81
5.28
6.59
3.74

120.289
120.304
140.689
108.184
108.022
125.354
98.5392
113.339
131.995
99.48
109.307
126.868
96.9933

140
166
166
166
166
166
166
166
166
166
166
166
166

99.51
72.03
80.29
56.11
82.61
93.5
63.62
76.12
85.4
61.22
84.19
95.57
68.76

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 120.2888 kN/m2
pmax = 140.6887 kN/m2
pmin =

99.51 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
262 5 1.5 (DL+LL)
109.8988
3.26
F9-SC5 6 1.2 (DL+LL+EQX)
96.164
2.62
0
7 1.5 (DL+EQX)
110.4887
3.31
0
8 0.9DL+1.5EQX
82.14417
2
0
9 1.2 (DL+LL-EQX)
95.312
2.59
0
10 1.5 (DL-EQX)
109.4237
3.27
0
11 0.9DL-1.5EQX
81.07917
1.96
0
12 1.2 (DL+LL+EQZ)
94.72883 12.48
0
13 1.5 (DL+EQZ)
108.6945 15.64
0
14 0.9DL+1.5EQZ
80.35 14.32
0
15 1.2 (DL+LL-EQZ)
96.74733
7.28
0
16 1.5 (DL-EQZ)
111.2178
9.06
0
17 0.9DL-1.5EQZ
82.87333 10.38
Joint

Mzz/Zzz
(3)
7.13
21.52
26.89
24.04
10.12
12.66
15.5
6.13
7.66
4.81
5.28
6.59
3.74

pmin =

56.11

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

120.289
120.304
140.689
108.185
108.022
125.354
98.54
113.339
131.995
99.48
109.308
126.868
96.994

113.769
115.064
134.069
104.185
102.842
118.814
94.62
88.379
100.715
70.84
94.748
108.748
76.234

99.509
72.024
80.289
56.105
82.602
93.494
63.62
76.119
85.395
61.22
84.188
95.568
68.754

106.03
77.264
86.909
60.105
87.782
100.03
67.54
101.08
116.68
89.86
98.748
113.69
89.514

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
262
F9-SC5
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
17.27386 234.57
6 1.2 (DL+LL+EQX)
43.74233 234.57
7 1.5 (DL+EQX)
54.68036 234.57
8 0.9DL+1.5EQX
48.44872 234.57
9 1.2 (DL+LL-EQX)
21.66648 234.57
10 1.5 (DL-EQX)
27.13719 234.57
11 0.9DL-1.5EQX
31.54582 234.57
12 1.2 (DL+LL+EQZ)
39.39273 234.57
13 1.5 (DL+EQZ)
49.33569 234.57
14 0.9DL+1.5EQZ
44.01784 234.57
15 1.2 (DL+LL-EQZ)
24.23804 234.57
16 1.5 (DL-EQZ)
30.19463 234.57
17 0.9DL-1.5EQZ
32.00251 234.57

424.83
342.42
428.37
258.3
337.31
421.98
251.91
333.81
417.6
247.53
345.92
432.74
262.67

38.18
13.2
12.13
10.18
26.4
24.2
15.43
14.43
13.22
10.96
23.95
22.11
15.54

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
15.30337
28.14917
35.18912
29.43436
9.093528
11.41898
14.20046
26.0101
32.56391
27.66768
14.73994
18.37122
18.21425

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

300
300

mm
mm

2000
3000
425
0.220

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
659.39
576.98
662.93
492.87
571.87
656.54
486.48
568.37
652.17
482.1
580.48
667.31
497.24

21.55
10.25
9.42
8.38
31.45
28.75
17.13
10.93
10.02
8.72
19.7
18.17
13.65

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column = 432.737 kN
Punching Shear,P =
432.737 x (( 2 x 3 ) - ( 0.725 x 0.725 ))
( 2 * 3 )
P = 394.83 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
300
300
1
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

725
725
2900

mm
mm
mm

Depth Required 394830


=
1.37 x2900
= 99.38 mm
Shear Resistance = 1.37 x 2900 x 425 / 1000
1688
kN
140.689

kN/m2

B) One Way Shear


925
0

1350

124.107

kN/m2

116.488

kN/m2

425

500

3000

300

300
500
850
425

425

2000

134.069

kN/m2
137.876 kN/m2

140.689

kN/m2

139.283

kN/m2

86.909

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 140.689 - 25 x 0.5 - 18 x ( 2 101.189 kN/m2
-- For without
Length at critical section =
2000
mm
Width at critical section =
925
mm
Shear Force = 101.189 x 2 x 0.925
= 187.1997 kN
At Width
Maximum Pressure = 140.689 - 25 x 0.5 - 18 x ( 2 101.189 kN/m2
-- For without
Length at critical section =
3000
mm
Width at critical section =
425
mm
Shear Force = 101.189 x 3 x 0.425
= 129.016 kN

0.5 )
Buoynacy Condition With Stress Increse

0.5 )
Buoynacy Condition With Stress Increse

Designed Shear Strength = 187.19965 kN


Corresponding Length =
2000
mm
% Ast =

0.220

Allowable Shear Stress =


0.338
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.338 x 1
2

N/mm
=
0.338
Depth Required = 187199.65
0.338 x 2000
=
352
mm
Check For Depth @ Critical Section
Critical section from face of
column =
425
mm
Min. Length from column face to
edge of footing =
850
Depth @ Edge of fdn D1 =
500
Depth @ face of column D =
500
Depth @ Critical s/c =
500
Effe. Depth @ Critical s/c =
425
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure = 140.689
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 75 + 159.57 ) / ( 2 x 3 )
39.1
101.589 kN/m2
1.35

Bending Moment = 101.589 x 1.35 x 1.35 / 2


= 92.57 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Mini.% of re-bar =
Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

933.74
0.2
850
16
200.96
215
215

1-

(4.6 x Mu )
fck x b x d2

fy
mm2
%
mm2
mm dia bars
mm2
mm

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

934.7

mm

Provide 16 mm dia Bars @ 215 mm spacing bothways

i.e.0.22%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
234.57 kN
Area Load = 234.57 / (2 x 3)

Maxi. Projection of fdn =

39.1

kN/m2

1.35

Bending Moment = 39.1 x 1.35 x 1.35 / 2


=
Ast =

35.63

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

352.52

Mini % of Re-bar =

0.12

Ast =
Use

510
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

221
220

mm
mm
2
Area Provided = 513.819 mm
Provide 12 mm dia Bars @ 220 mm spacing bothways

i.e.0.121%

Summary Of Design :Length Of Footing :2000 mm


WIdth Of Footing :3000 mm
Depth Of Footing :500
mm
Depth @ Edge of fdn D1 =
500
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 220 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 215 mm spacing bothways

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

DESIGN OF ISOLATED FOOTING


Type of Footing =

PAD
25

kN/m

Density Of Soil =

18

kN/m3

Density of Water =
Depth Of Foundation =

10
2

kN/m
m

=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 104 x 1.25 + 18 x 2
=
166
kN/m2
(Where increase in SBC is allowed.)
Water Table Considered =
NO
For with Buoyancy:Gross SBC = 104 + 2 x 18
=
140
kN/m2
(Where increase in SBC is not allowed.)
Gross SBC = 1.25 x 104 + 2 x 18
=
166
kN/m2
(Where increase in SBC is allowed.)
FY
Length Of Footing L
Width Of Footing W
Thickness Of Fdn T
Depth @ Edge of fdn D1
Width Of Pedestal wp
Length Of Pedestal lp
Height Of Pedestal
Coefficient Of Friction
Ground Water Table Ht.

=
=
=
=
=
=
=
=
=
=

30

N/mm2

415
2
3
0.5
0.5
0.3
0.3
0
0.5
0

N/mm2
m
m
m
m
m
m
m
m

1.35

Wp

1.35
Z

0.85

Lp

F9

COLUMN NO.

SC6

REFER STAAD
ANALYSIS FILE
SUPPORT REACTION.

Net SBC =
104
kN/m
(As per foundation design basis.)
For without Buoyancy:Gross SBC = 104 + 2 x 18

FC =

FOOTING NO.
3

Density Of Concrete =

0.85

Load Calculation for Footing & Soil:Self Wt. Of Footing = 25 x 2 x 3 x 0.5


=
75
kN
Buoyant Self wt. of Fdn = 0 x 2 x 3 x 0.5
=
0
kN

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Weight of Soil = [(2 x 3) - (0.3 x 0.3)] x (2 - 0.5 ) x 18


=
159.57 kN
Buoyant weight of Soil = [(2 x 3) - (0.3 x 0.3)] x (2 - 0.5 ) x 0
0
kN
Self Wt. Of Pedestal =

25 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Self Wt. Of Pedestal =

0 x 0.3 x 0.3 x 0
=
0
kN
(Not considered here since it is modelled in STAAD)

Weight of Footing + Soil = 75 + 0 + 159.57


=
234.57 kN
Weight of Footing + Soil = 0 + 0 + 0
with buoyancy
0
kN

JOINT
273
F9-SC6

INPUT:- INPUT STAAD SUPPORT REACTION (Unit


LOAD
FORCE-X FORCE-Y
5 1.5 (DL+LL)
0.173
310.52
6 1.2 (DL+LL+EQX)
-9.017
248.444
7 1.5 (DL+EQX)
-11.243 312.518
8 0.9DL+1.5EQX
-11.323 187.525
9 1.2 (DL+LL-EQX)
9.294
248.388
10 1.5 (DL-EQX)
11.646
312.449
11 0.9DL-1.5EQX
11.565
187.456
12 1.2 (DL+LL+EQZ)
-0.416
227.083
13 1.5 (DL+EQZ)
-0.491
285.817
14 0.9DL+1.5EQZ
-0.571
160.824
15 1.2 (DL+LL-EQZ)
0.692
269.749
16 1.5 (DL-EQZ)
0.894
339.15
17 0.9DL-1.5EQZ
0.813
214.156

kN - m)
FORCE-Z
-8.69
-7.055
-8.817
-5.342
-6.849
-8.561
-5.085
-29.722
-37.151
-33.676
15.818
19.773
23.249

MOM-X
-11.428
-9.307
-11.634
-7.063
-8.978
-11.222
-6.651
-45.925
-57.407
-52.835
27.64
34.551
39.122

MOM-Y
MOM Z
-0.257 -0.613
0.872
21.372
1.101
26.651
1.2
26.922
-1.283 -22.352
-1.592 -28.003
-1.494 -27.733
-0.43
0.671
-0.525
0.775
-0.427
1.046
0.018
-1.651
0.035
-2.127
0.133
-1.857

Check for Maximum and Minimum Pressure at the Base:- Without Buoyancy
Area of Footing A = 2 x 3
A =
Section Modulus Zxx =
Zxx =
Section Modulus Zzz =
Zzz =

m2

1/6 x 2 x 3 x 3
3

m3

1/6 x 3 x 2 x 2
2

m3

Total Vertical Load P = 310.52 + 234.57


=
545.09 kN

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

P/A = 545.09 / (2 x 3 )
=

90.848

kN/m

Mxx/Zxx = 11.428 / 3
Mxx/Zxx =

3.810

kN/m

Mzz/Zzz = 0.613 / 2
Mzz/Zzz =

0.307

kN/m

Maxi.Soil Pressure pmax = 90.848 + 3.81 + 0.307


pmax =

94.97

kN/m

<

140

kN/m

Less Than Allowable Hence O.K.


Mini.Soil Pressure pmin = 90.848 - 3.81 - 0.307
pmin =

86.74

kN/m2

>

No Tension at the Base of Footing

Check for Overturning:- Without Buoyancy


Overturning Moment = Resultant of Mx & Mz
=
11.45
kN.m
Calculation of Stabilizing Moment
Due to External Load = 310.52 x 2 / 2
=
310.52 kN.m
Due to wt. of Pedestral = 0 x 1
=
0
Due to Self Wt. of Fdn = 75 x 1
=
75

kN.m

kN.m

Due to Wt. of Soil = 159.57 x 1


=
159.57 kN.m
Total Stabilizing moment = 310.52 + 0 + 75 + 159.57
=
545.09 kN.m
F.O.S. against Overturning = 545.09 / 11.45
= 47.6061 > 1.2 Hence Safe
Check for Sliding:Resultant Shear Force =

8.7

kN

Total Vertical Load = 545.09 kN


F.O.S. against Sliding = 545.09 x 0.5 / 8.7
= 31.33
> 1.5 Hence Safe

SAG

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases with Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
273 5 1.5 (DL+LL)
310.52 51.75333
F9-SC6 6 1.2 (DL+LL+EQX)
248.444 41.40733
0
7 1.5 (DL+EQX)
312.518 52.08633
0
8 0.9DL+1.5EQX
187.525 31.25417
0
9 1.2 (DL+LL-EQX)
248.388 41.398
0
10 1.5 (DL-EQX)
312.449 52.07483
0
11 0.9DL-1.5EQX
187.456 31.24267
0
12 1.2 (DL+LL+EQZ)
227.083 37.84717
0
13 1.5 (DL+EQZ)
285.817 47.63617
0
14 0.9DL+1.5EQZ
160.824 26.804
0
15 1.2 (DL+LL-EQZ)
269.749 44.95817
0
16 1.5 (DL-EQZ)
339.15
56.525
0
17 0.9DL-1.5EQZ
214.156 35.69267
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

3.81
3.11
3.88
2.36
3
3.75
2.22
15.31
19.14
17.62
9.22
11.52
13.05

0.31
10.69
13.33
13.47
11.18
14.01
13.87
0.34
0.39
0.53
0.83
1.07
0.93

55.8733
55.2073
69.2963
47.0842
55.578
69.8348
47.3327
53.4972
67.1662
44.954
55.0082
69.115
49.6727

140
166
166
166
166
166
166
166
166
166
166
166
166

47.64
27.61
34.88
15.43
27.22
34.32
15.16
22.2
28.11
8.66
34.91
43.94
21.72

Summary of Bearing Pressure (With Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 55.87333 kN/m2
pmax = 69.83483 kN/m2
pmin =

Load
Mxx/Zxx
P/A (1)
Case
(2)
273 5 1.5 (DL+LL)
51.75333
3.81
F9-SC6 6 1.2 (DL+LL+EQX)
41.40733
3.11
0
7 1.5 (DL+EQX)
52.08633
3.88
0
8 0.9DL+1.5EQX
31.25417
2.36
0
9 1.2 (DL+LL-EQX)
41.398
3
0
10 1.5 (DL-EQX)
52.07483
3.75
0
11 0.9DL-1.5EQX
31.24267
2.22
0
12 1.2 (DL+LL+EQZ)
37.84717 15.31
0
13 1.5 (DL+EQZ)
47.63617 19.14
0
14 0.9DL+1.5EQZ
26.804 17.62
0
15 1.2 (DL+LL-EQZ)
44.95817
9.22
0
16 1.5 (DL-EQZ)
56.525 11.52
0
17 0.9DL-1.5EQZ
35.69267 13.05
Joint

kN/m2

Mzz/Zzz
(3)
0.31
10.69
13.33
13.47
11.18
14.01
13.87
0.34
0.39
0.53
0.83
1.07
0.93

pmin =

8.66

kN/m2

1+2+3

1-2+3

1-2-3

1+2-3

55.874
55.208
69.297
47.085
55.578
69.835
47.333
53.498
67.167
44.954
55.009
69.115
49.673

48.254
48.988
61.537
42.365
49.578
62.335
42.893
22.878
28.887
9.714
36.569
46.075
23.573

47.634
27.608
34.877
15.425
27.218
34.315
15.153
22.198
28.107
8.654
34.909
43.935
21.713

55.254
33.828
42.637
20.145
33.218
41.815
19.593
52.818
66.387
43.894
53.349
66.975
47.813

Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Check for All Load Cases without Buoyancy:Check for Maxi. & Mini. Pressure at Base of Footing:Load
Total
P/A
Case
Load
273 5 1.5 (DL+LL)
545.09 90.84833
F9-SC6 6 1.2 (DL+LL+EQX)
483.014 80.50233
0
7 1.5 (DL+EQX)
547.088 91.18133
0
8 0.9DL+1.5EQX
422.095 70.34917
0
9 1.2 (DL+LL-EQX)
482.958 80.493
0
10 1.5 (DL-EQX)
547.019 91.16983
0
11 0.9DL-1.5EQX
422.026 70.33767
0
12 1.2 (DL+LL+EQZ)
461.653 76.94217
0
13 1.5 (DL+EQZ)
520.387 86.73117
0
14 0.9DL+1.5EQZ
395.394 65.899
0
15 1.2 (DL+LL-EQZ)
504.319 84.05317
0
16 1.5 (DL-EQZ)
573.72
95.62
0
17 0.9DL-1.5EQZ
448.726 74.78767
Joint

Mxx/Zxx

Mzz/Zzz

pmax

pall

pmin

Result

3.81
3.11
3.88
2.36
3
3.75
2.22
15.31
19.14
17.62
9.22
11.52
13.05

0.31
10.69
13.33
13.47
11.18
14.01
13.87
0.34
0.39
0.53
0.83
1.07
0.93

94.9683
94.3023
108.391
86.1792
94.673
108.93
86.4277
92.5922
106.261
84.049
94.1032
108.21
88.7677

140
166
166
166
166
166
166
166
166
166
166
166
166

86.73
66.71
73.98
54.52
66.32
73.41
54.25
61.3
67.21
47.75
74.01
83.03
60.81

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Summary of Bearing Pressure (Without Buoyancy)


Without Stress Increase:With Stress Increase:pmax = 94.96833 kN/m2
pmax = 108.9298 kN/m2
pmin =

86.73 kN/m2

Load
Mxx/Zxx
P/A (1)
Case
(2)
273 5 1.5 (DL+LL)
90.84833
3.81
F9-SC6 6 1.2 (DL+LL+EQX)
80.50233
3.11
0
7 1.5 (DL+EQX)
91.18133
3.88
0
8 0.9DL+1.5EQX
70.34917
2.36
0
9 1.2 (DL+LL-EQX)
80.493
3
0
10 1.5 (DL-EQX)
91.16983
3.75
0
11 0.9DL-1.5EQX
70.33767
2.22
0
12 1.2 (DL+LL+EQZ)
76.94217 15.31
0
13 1.5 (DL+EQZ)
86.73117 19.14
0
14 0.9DL+1.5EQZ
65.899 17.62
0
15 1.2 (DL+LL-EQZ)
84.05317
9.22
0
16 1.5 (DL-EQZ)
95.62 11.52
0
17 0.9DL-1.5EQZ
74.78767 13.05
Joint

Mzz/Zzz
(3)
0.31
10.69
13.33
13.47
11.18
14.01
13.87
0.34
0.39
0.53
0.83
1.07
0.93

pmin =

1+2+3

1-2+3

94.969 87.349
94.303 88.083
108.392 100.632
86.18
81.46
94.673 88.673
108.93 101.43
86.428 81.988
92.593 61.973
106.262 67.982
84.049 48.809
94.104 75.664
108.21
85.17
88.768 62.668

47.75

kN/m2

1-2-3

1+2-3

86.729
66.703
73.972
54.52
66.313
73.41
54.248
61.293
67.202
47.749
74.004
83.03
60.808

94.349
72.923
81.732
59.24
72.313
80.91
58.688
91.913
105.48
82.989
92.444
106.07
86.908

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Check for Overturning & Sliding:Check against Overturning


Stabilize Moment
Load
OverJoint
(Soil,
Case turning
FOS
Load on
Ped,
Moment.
Ped
Fdn)
273
F9-SC6
0
0
0
0
0
0
0
0
0
0
0

5 1.5 (DL+LL)
11.44443 234.57
6 1.2 (DL+LL+EQX)
23.31057 234.57
7 1.5 (DL+EQX)
29.07965 234.57
8 0.9DL+1.5EQX
27.83307 234.57
9 1.2 (DL+LL-EQX)
24.08768 234.57
10 1.5 (DL-EQX)
30.16789 234.57
11 0.9DL-1.5EQX
28.51938 234.57
12 1.2 (DL+LL+EQZ)
45.9299 234.57
13 1.5 (DL+EQZ)
57.41223 234.57
14 0.9DL+1.5EQZ
52.84535 234.57
15 1.2 (DL+LL-EQZ)
27.68927 234.57
16 1.5 (DL-EQZ)
34.61641 234.57
17 0.9DL-1.5EQZ
39.16605 234.57

310.52
248.45
312.52
187.53
248.39
312.45
187.46
227.09
285.82
160.83
269.75
339.15
214.16

47.63
20.73
18.82
15.17
20.06
18.14
14.8
10.06
9.07
7.49
18.22
16.58
11.46

Check against Sliding


Result
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

Total
Hori.
Force
8.691722
11.44899
14.28792
12.51988
11.54501
14.45407
12.63354
29.72491
37.15424
33.68084
15.83313
19.7932
23.26321

Check For Shear


a) Two Way Shear
Limit State Method

d/2

d/2

Critical Section = At distance d/2 from face of column


Concrete Grade =
Column Details
Length =
Width =
Foundation Details
Length =
Width =
Effective Depth =
Percentage Of Steel =

30

N/mm2

300
300

mm
mm

2000
3000
425
0.201

mm
mm
mm
%

SAG

Total
FOS for
Result
Vert.
Sliding
Load
545.09
483.01
547.09
422.1
482.96
547.02
422.03
461.65
520.39
395.39
504.32
573.72
448.73

31.36
21.1
19.15
16.86
20.92
18.93
16.71
7.77
7.01
5.87
15.93
14.5
9.65

SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE
SAFE

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

SAG

Punching Load
Maximum Load on Column =
339.15 kN
Punching Shear,P =
339.15 x (( 2 x 3 ) - ( 0.725 x 0.725 ))
( 2 * 3 )
P = 309.44 kN
Shear Resistance Of Concrete (Vc)
= vc x bc x d -----Refer to clause no. 31.6.3.1 of IS 456
where vc = ks x tc
ks = 0.5 + c -----should not be greater than 1
c = Short Side Of Column
Long Side Of Column
300
300
1
1

c =
c =
ks =

N/mm2
tc =
1.37
bc = Appropriate perimeter at distance d/2
Length of critical section =
Width of critical section =
Perimeter of critical section =

725
725
2900

mm
mm
mm

Depth Required 309440


=
1.37 x2900
= 77.89 mm
Shear Resistance = 1.37 x 2900 x 425 / 1000
1688
kN
108.93

kN/m2

B) One Way Shear


925
0

1350

100.291

kN/m2

96.321

kN/m2

425

500

3000

300

300
500
850
425

425

2000

101.43

kN/m2
105.743 kN/m2

108.93

kN/m2

107.337

kN/m2

80.91

kN/m2

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

At Length
Maximum Pressure = 108.93 - 25 x 0.5 - 18 x
69.43 kN/m2
-- For
Length at critical section =
2000
mm
Width at critical section =
925
mm
Shear Force = 69.43 x 2 x 0.925
= 128.4455 kN
At Width
Maximum Pressure = 108.93 - 25 x 0.5 - 18 x
69.43 kN/m2
-- For
Length at critical section =
3000
mm
Width at critical section =
425
mm
Shear Force = 69.43 x 3 x 0.425
= 88.52325 kN

( 2 - 0.5 )
without Buoynacy Condition With Stress Increse

( 2 - 0.5 )
without Buoynacy Condition With Stress Increse

Designed Shear Strength = 128.4455 kN


Corresponding Length =
2000
mm
% Ast =

0.201

Allowable Shear Stress =


0.33
N/mm2
----Refer Table 19 of IS 456
k =
1
---- Refer clause no. 40.2 of IS 456
Case = Without Stress Increase
Increaae In Shear Stress = Not Allowed
tc = 1 x 0.33 x 1
2

N/mm
=
0.33
Depth Required = 128445.5
0.33 x 2000
=
270
mm
Check For Depth @ Critical Section
Critical section from face of
column =
425
mm
Min. Length from column face to
edge of footing =
850
Depth @ Edge of fdn D1 =
500
Depth @ face of column D =
500
Depth @ Critical s/c =
500
Effe. Depth @ Critical s/c =
425
Design Of Foundation
a) Calculation of Reinforcement at
Maximum Pressure =
108.93
Pressure due to Soil & Fdn wt =
=
Net causing moment =
Maximum Projection of fdn =

mm
mm
mm
mm
mm

Depth is O.K.

Bottom
-- Without Buoyancy Load Case
( 75 + 159.57 ) / ( 2 x 3 )
39.1
69.83 kN/m2
1.35

Bending Moment = 69.83 x 1.35 x 1.35 / 2


= 63.63 kN.m
Ast =
0.5 x fck x b x d

1 -

Ast =
Use
Area of bar =
Spacing =
Provide Spacing =

635.46
0.2
850
16
200.96
236
235

1-

(4.6 x Mu )
fck x b x d2

fy
Ast =
Mini.% of re-bar =

SAG

mm2
%
mm2
mm dia bars
mm2
mm

JOB NO.
CUSTOMER

DATE
DESIGNED BY
CHECKED BY

DESCRIPTION

Area Provided =

855.15

mm

Provide 16 mm dia Bars @ 235 mm spacing bothways

i.e.0.202%

b) Calculation of Reinforcement at Top


Reinforcement at top is checked for overburden load on top of foundation
since 100% of foundation is not in contact with soil.
Wt. Of Soil + Fdn wt. =
234.57 kN
Area Load = 234.57 / (2 x 3)

Maxi. Projection of fdn =

39.1

kN/m2

1.35

Bending Moment = 39.1 x 1.35 x 1.35 / 2


=
Ast =

35.63

kN.m

0.5 x fck x b x d

1 -

fy
Ast =

352.52

Mini % of Re-bar =

0.12

Ast =
Use

510
12

Area of bar =
Spacing =
Provide Spacing =

113.04

1-

(4.6 x Mu )
fck x b x d2

mm2
%
mm2
mm dia bars
2
mm

221
220

mm
mm
2
Area Provided = 513.819 mm
Provide 12 mm dia Bars @ 220 mm spacing bothways

i.e.0.121%

Summary Of Design :Length Of Footing :2000 mm


WIdth Of Footing :3000 mm
Depth Of Footing :500
mm
Depth @ Edge of fdn D1 =
500
mm
Reinforcement :At Top :- Provide 12 mm dia Bars @ 220 mm spacing bothways
At Bottom :Provide 16 mm dia Bars @ 235 mm spacing bothways

SAG

% pt
0
0.15
0.16
0.17
0.18
0.19
0.2
0.21
0.22
0.23
0.24
0.25
0.26
0.27
0.28
0.29
0.3
0.31
0.32
0.33
0.34
0.35
0.36
0.37
0.38
0.39
0.4
0.41
0.42
0.43
0.44
0.45
0.46
0.47
0.48
0.49
0.5
0.51
0.52
0.53
0.54
0.55
0.56
0.57
0.58
0.59
0.6
0.61

DESIGN SHEAR STRENGTH OF CONCRETE Tc N/mm2


M15
M20
M25
M30
M35
M40 & ABOVE
15
20
25
30
35
40
0.280
0.280
0.290
0.290
0.290
0.300
0.287
0.288
0.297
0.298
0.298
0.308
0.294
0.296
0.304
0.306
0.306
0.316
0.301
0.304
0.311
0.314
0.314
0.324
0.308
0.312
0.318
0.322
0.322
0.332
0.315
0.320
0.325
0.330
0.330
0.340
0.322
0.328
0.332
0.338
0.338
0.348
0.329
0.336
0.339
0.346
0.346
0.356
0.336
0.344
0.346
0.354
0.354
0.364
0.343
0.352
0.353
0.362
0.362
0.372
0.350
0.360
0.360
0.370
0.370
0.380
0.354
0.365
0.365
0.375
0.375
0.385
0.359
0.370
0.370
0.380
0.380
0.390
0.363
0.374
0.376
0.386
0.386
0.396
0.368
0.379
0.381
0.391
0.391
0.401
0.372
0.384
0.386
0.396
0.396
0.406
0.376
0.389
0.391
0.401
0.401
0.411
0.381
0.394
0.396
0.406
0.406
0.416
0.385
0.398
0.402
0.412
0.412
0.422
0.390
0.403
0.407
0.417
0.417
0.427
0.394
0.408
0.412
0.422
0.422
0.432
0.398
0.413
0.417
0.427
0.427
0.437
0.403
0.418
0.422
0.432
0.432
0.442
0.407
0.422
0.428
0.438
0.438
0.448
0.412
0.427
0.433
0.443
0.443
0.453
0.416
0.432
0.438
0.448
0.448
0.458
0.420
0.437
0.443
0.453
0.453
0.463
0.425
0.442
0.448
0.458
0.458
0.468
0.429
0.446
0.454
0.464
0.464
0.474
0.434
0.451
0.459
0.469
0.469
0.479
0.438
0.456
0.464
0.474
0.474
0.484
0.442
0.461
0.469
0.479
0.479
0.489
0.447
0.466
0.474
0.484
0.484
0.494
0.451
0.470
0.480
0.490
0.490
0.500
0.456
0.475
0.485
0.495
0.495
0.505
0.460
0.480
0.490
0.500
0.500
0.510
0.463
0.483
0.493
0.504
0.504
0.514
0.466
0.486
0.496
0.507
0.507
0.517
0.470
0.490
0.500
0.511
0.511
0.521
0.473
0.493
0.503
0.514
0.514
0.524
0.476
0.496
0.506
0.518
0.518
0.528
0.479
0.499
0.509
0.522
0.522
0.532
0.482
0.502
0.512
0.525
0.525
0.535
0.486
0.506
0.516
0.529
0.529
0.539
0.489
0.509
0.519
0.532
0.532
0.542
0.492
0.512
0.522
0.536
0.536
0.546
0.495
0.515
0.525
0.540
0.540
0.550

0.62
0.63
0.64
0.65
0.66
0.67
0.68
0.69
0.7
0.71
0.72
0.73
0.74
0.75
0.76
0.77
0.78
0.79
0.8
0.81
0.82
0.83
0.84
0.85
0.86
0.87
0.88
0.89
0.9
0.91
0.92
0.93
0.94
0.95
0.96
0.97
0.98
0.99
1
1.01
1.02
1.03
1.04
1.05
1.06
1.07
1.08
1.09
1.1
1.11
1.12
1.13

0.498
0.502
0.505
0.508
0.511
0.514
0.518
0.521
0.524
0.527
0.530
0.534
0.537
0.540
0.542
0.545
0.547
0.550
0.552
0.554
0.557
0.559
0.562
0.564
0.566
0.569
0.571
0.574
0.576
0.578
0.581
0.583
0.586
0.588
0.590
0.593
0.595
0.598
0.600
0.602
0.603
0.605
0.606
0.608
0.610
0.611
0.613
0.614
0.616
0.618
0.619
0.621

0.518
0.522
0.525
0.528
0.531
0.534
0.538
0.541
0.544
0.547
0.550
0.554
0.557
0.560
0.562
0.565
0.567
0.570
0.572
0.574
0.577
0.579
0.582
0.584
0.586
0.589
0.591
0.594
0.596
0.598
0.601
0.603
0.606
0.608
0.610
0.613
0.615
0.618
0.620
0.622
0.624
0.626
0.628
0.630
0.632
0.634
0.636
0.638
0.640
0.642
0.644
0.646

0.528
0.532
0.535
0.538
0.541
0.544
0.548
0.551
0.554
0.557
0.560
0.564
0.567
0.570
0.573
0.576
0.578
0.581
0.584
0.587
0.590
0.592
0.595
0.598
0.601
0.604
0.606
0.609
0.612
0.615
0.618
0.620
0.623
0.626
0.629
0.632
0.634
0.637
0.640
0.642
0.645
0.647
0.650
0.652
0.654
0.657
0.659
0.662
0.664
0.666
0.669
0.671

0.543
0.547
0.550
0.554
0.558
0.561
0.565
0.568
0.572
0.576
0.579
0.583
0.586
0.590
0.593
0.596
0.598
0.601
0.604
0.607
0.610
0.612
0.615
0.618
0.621
0.624
0.626
0.629
0.632
0.635
0.638
0.640
0.643
0.646
0.649
0.652
0.654
0.657
0.660
0.662
0.664
0.666
0.668
0.670
0.672
0.674
0.676
0.678
0.680
0.682
0.684
0.686

0.543
0.547
0.550
0.554
0.558
0.561
0.565
0.568
0.572
0.576
0.579
0.583
0.586
0.590
0.593
0.596
0.600
0.603
0.606
0.609
0.612
0.616
0.619
0.622
0.625
0.628
0.632
0.635
0.638
0.641
0.644
0.648
0.651
0.654
0.657
0.660
0.664
0.667
0.670
0.672
0.675
0.677
0.680
0.682
0.684
0.687
0.689
0.692
0.694
0.696
0.699
0.701

0.553
0.557
0.560
0.564
0.568
0.571
0.575
0.578
0.582
0.586
0.589
0.593
0.596
0.600
0.603
0.606
0.610
0.613
0.616
0.619
0.622
0.626
0.629
0.632
0.635
0.638
0.642
0.645
0.648
0.651
0.654
0.658
0.661
0.664
0.667
0.670
0.674
0.677
0.680
0.682
0.685
0.687
0.690
0.692
0.694
0.697
0.699
0.702
0.704
0.706
0.709
0.711

1.14
1.15
1.16
1.17
1.18
1.19
1.2
1.21
1.22
1.23
1.24
1.25
1.26
1.27
1.28
1.29
1.3
1.31
1.32
1.33
1.34
1.35
1.36
1.37
1.38
1.39
1.4
1.41
1.42
1.43
1.44
1.45
1.46
1.47
1.48
1.49
1.5
1.51
1.52
1.53
1.54
1.55
1.56
1.57
1.58
1.59
1.6
1.61
1.62
1.63
1.64
1.65

0.622
0.624
0.626
0.627
0.629
0.630
0.632
0.634
0.635
0.637
0.638
0.640
0.642
0.643
0.645
0.646
0.648
0.650
0.651
0.653
0.654
0.656
0.658
0.659
0.661
0.662
0.664
0.666
0.667
0.669
0.670
0.672
0.674
0.675
0.677
0.678
0.680
0.681
0.682
0.684
0.685
0.686
0.687
0.688
0.690
0.691
0.692
0.693
0.694
0.696
0.697
0.698

0.648
0.650
0.652
0.654
0.656
0.658
0.660
0.662
0.664
0.666
0.668
0.670
0.672
0.674
0.676
0.678
0.680
0.682
0.684
0.686
0.688
0.690
0.692
0.694
0.696
0.698
0.700
0.702
0.704
0.706
0.708
0.710
0.712
0.714
0.716
0.718
0.720
0.721
0.722
0.724
0.725
0.726
0.727
0.728
0.730
0.731
0.732
0.733
0.734
0.736
0.737
0.738

0.674
0.676
0.678
0.681
0.683
0.686
0.688
0.690
0.693
0.695
0.698
0.700
0.702
0.703
0.705
0.706
0.708
0.710
0.711
0.713
0.714
0.716
0.718
0.719
0.721
0.722
0.724
0.726
0.727
0.729
0.730
0.732
0.734
0.735
0.737
0.738
0.740
0.742
0.743
0.745
0.746
0.748
0.750
0.751
0.753
0.754
0.756
0.758
0.759
0.761
0.762
0.764

0.688
0.690
0.692
0.694
0.696
0.698
0.700
0.702
0.704
0.706
0.708
0.710
0.712
0.714
0.716
0.718
0.720
0.722
0.724
0.726
0.728
0.730
0.732
0.734
0.736
0.738
0.740
0.742
0.744
0.746
0.748
0.750
0.752
0.754
0.756
0.758
0.760
0.762
0.763
0.765
0.766
0.768
0.770
0.771
0.773
0.774
0.776
0.778
0.779
0.781
0.782
0.784

0.704
0.706
0.708
0.711
0.713
0.716
0.718
0.720
0.723
0.725
0.728
0.730
0.732
0.734
0.736
0.738
0.740
0.742
0.744
0.746
0.748
0.750
0.752
0.754
0.756
0.758
0.760
0.762
0.764
0.766
0.768
0.770
0.772
0.774
0.776
0.778
0.780
0.782
0.783
0.785
0.786
0.788
0.790
0.791
0.793
0.794
0.796
0.798
0.799
0.801
0.802
0.804

0.714
0.716
0.718
0.721
0.723
0.726
0.728
0.730
0.733
0.735
0.738
0.740
0.742
0.744
0.746
0.748
0.750
0.752
0.754
0.756
0.758
0.760
0.762
0.764
0.766
0.768
0.770
0.772
0.774
0.776
0.778
0.780
0.782
0.784
0.786
0.788
0.790
0.792
0.794
0.796
0.798
0.800
0.802
0.804
0.806
0.808
0.810
0.812
0.814
0.816
0.818
0.820

1.66
1.67
1.68
1.69
1.7
1.71
1.72
1.73
1.74
1.75
1.76
1.77
1.78
1.79
1.8
1.81
1.82
1.83
1.84
1.85
1.86
1.87
1.88
1.89
1.9
1.91
1.92
1.93
1.94
1.95
1.96
1.97
1.98
1.99
2
2.01
2.02
2.03
2.04
2.05
2.06
2.07
2.08
2.09
2.1
2.11
2.12
2.13
2.14
2.15
2.16
2.17

0.699
0.700
0.702
0.703
0.704
0.705
0.706
0.708
0.709
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710

0.739
0.740
0.742
0.743
0.744
0.745
0.746
0.748
0.749
0.750
0.752
0.753
0.755
0.756
0.758
0.760
0.761
0.763
0.764
0.766
0.768
0.769
0.771
0.772
0.774
0.776
0.777
0.779
0.780
0.782
0.784
0.785
0.787
0.788
0.790
0.791
0.792
0.792
0.793
0.794
0.795
0.796
0.796
0.797
0.798
0.799
0.800
0.800
0.801
0.802
0.803
0.804

0.766
0.767
0.769
0.770
0.772
0.774
0.775
0.777
0.778
0.780
0.782
0.783
0.785
0.786
0.788
0.790
0.791
0.793
0.794
0.796
0.798
0.799
0.801
0.802
0.804
0.806
0.807
0.809
0.810
0.812
0.814
0.815
0.817
0.818
0.820
0.821
0.822
0.824
0.825
0.826
0.827
0.828
0.830
0.831
0.832
0.833
0.834
0.836
0.837
0.838
0.839
0.840

0.786
0.787
0.789
0.790
0.792
0.794
0.795
0.797
0.798
0.800
0.802
0.803
0.805
0.806
0.808
0.810
0.811
0.813
0.814
0.816
0.818
0.819
0.821
0.822
0.824
0.826
0.827
0.829
0.830
0.832
0.834
0.835
0.837
0.838
0.840
0.842
0.843
0.845
0.846
0.848
0.850
0.851
0.853
0.854
0.856
0.858
0.859
0.861
0.862
0.864
0.866
0.867

0.806
0.807
0.809
0.810
0.812
0.814
0.815
0.817
0.818
0.820
0.822
0.823
0.825
0.826
0.828
0.830
0.831
0.833
0.834
0.836
0.838
0.839
0.841
0.842
0.844
0.846
0.847
0.849
0.850
0.852
0.854
0.855
0.857
0.858
0.860
0.862
0.863
0.865
0.866
0.868
0.870
0.871
0.873
0.874
0.876
0.878
0.879
0.881
0.882
0.884
0.886
0.887

0.822
0.824
0.826
0.828
0.830
0.832
0.834
0.836
0.838
0.840
0.842
0.843
0.845
0.846
0.848
0.850
0.851
0.853
0.854
0.856
0.858
0.859
0.861
0.862
0.864
0.866
0.867
0.869
0.870
0.872
0.874
0.875
0.877
0.878
0.880
0.882
0.883
0.885
0.886
0.888
0.890
0.891
0.893
0.894
0.896
0.898
0.899
0.901
0.902
0.904
0.906
0.907

2.18
2.19
2.2
2.21
2.22
2.23
2.24
2.25
2.26
2.27
2.28
2.29
2.3
2.31
2.32
2.33
2.34
2.35
2.36
2.37
2.38
2.39
2.4
2.41
2.42
2.43
2.44
2.45
2.46
2.47
2.48
2.49
2.5
2.51
2.52
2.53
2.54
2.55
2.56
2.57
2.58
2.59
2.6
2.61
2.62
2.63
2.64
2.65
2.66
2.67
2.68
2.69

0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710

0.804
0.805
0.806
0.807
0.808
0.808
0.809
0.810
0.810
0.811
0.811
0.812
0.812
0.812
0.813
0.813
0.814
0.814
0.814
0.815
0.815
0.816
0.816
0.816
0.817
0.817
0.818
0.818
0.818
0.819
0.819
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820

0.842
0.843
0.844
0.845
0.846
0.848
0.849
0.850
0.851
0.852
0.854
0.855
0.856
0.857
0.858
0.860
0.861
0.862
0.863
0.864
0.866
0.867
0.868
0.869
0.870
0.872
0.873
0.874
0.875
0.876
0.878
0.879
0.880
0.881
0.882
0.882
0.883
0.884
0.885
0.886
0.886
0.887
0.888
0.889
0.890
0.890
0.891
0.892
0.893
0.894
0.894
0.895

0.869
0.870
0.872
0.874
0.875
0.877
0.878
0.880
0.881
0.882
0.884
0.885
0.886
0.887
0.888
0.890
0.891
0.892
0.893
0.894
0.896
0.897
0.898
0.899
0.900
0.902
0.903
0.904
0.905
0.906
0.908
0.909
0.910
0.911
0.912
0.914
0.915
0.916
0.917
0.918
0.920
0.921
0.922
0.923
0.924
0.926
0.927
0.928
0.929
0.930
0.932
0.933

0.889
0.890
0.892
0.894
0.895
0.897
0.898
0.900
0.901
0.902
0.904
0.905
0.906
0.907
0.908
0.910
0.911
0.912
0.913
0.914
0.916
0.917
0.918
0.919
0.920
0.922
0.923
0.924
0.925
0.926
0.928
0.929
0.930
0.931
0.932
0.934
0.935
0.936
0.937
0.938
0.940
0.941
0.942
0.943
0.944
0.946
0.947
0.948
0.949
0.950
0.952
0.953

0.909
0.910
0.912
0.914
0.915
0.917
0.918
0.920
0.921
0.922
0.924
0.925
0.926
0.927
0.928
0.930
0.931
0.932
0.933
0.934
0.936
0.937
0.938
0.939
0.940
0.942
0.943
0.944
0.945
0.946
0.948
0.949
0.950
0.951
0.952
0.954
0.955
0.956
0.957
0.958
0.960
0.961
0.962
0.963
0.964
0.966
0.967
0.968
0.969
0.970
0.972
0.973

2.7
2.71
2.72
2.73
2.74
2.75
2.76
2.77
2.78
2.79
2.8
2.81
2.82
2.83
2.84
2.85
2.86
2.87
2.88
2.89
2.9
2.91
2.92
2.93
2.94
2.95
2.96
2.97
2.98
2.99
3

0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710

0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820
0.820

0.896
0.897
0.898
0.898
0.899
0.900
0.901
0.902
0.902
0.903
0.904
0.905
0.906
0.906
0.907
0.908
0.909
0.910
0.910
0.911
0.912
0.913
0.914
0.914
0.915
0.916
0.917
0.918
0.918
0.919
0.920

0.934
0.935
0.936
0.938
0.939
0.940
0.941
0.942
0.942
0.943
0.944
0.945
0.946
0.946
0.947
0.948
0.949
0.950
0.950
0.951
0.952
0.953
0.954
0.954
0.955
0.956
0.957
0.958
0.958
0.959
0.960

0.954
0.955
0.956
0.958
0.959
0.960
0.961
0.962
0.964
0.965
0.966
0.967
0.968
0.970
0.971
0.972
0.973
0.974
0.976
0.977
0.978
0.979
0.980
0.982
0.983
0.984
0.985
0.986
0.988
0.989
0.990

0.974
0.975
0.976
0.978
0.979
0.980
0.981
0.982
0.984
0.985
0.986
0.987
0.988
0.990
0.991
0.992
0.993
0.994
0.996
0.997
0.998
0.999
1.000
1.002
1.003
1.004
1.005
1.006
1.008
1.009
1.010

Fck =

30

% pt =

0.26

Tc =

0.3752

Fck =

30

% pt =

0.22

Tc =

0.346

Fck =

30

% pt =

0.33

Tc =

0.4116

Fck =

30

% pt =

0.47

Tc =

0.4844

% pt
0.15
0.25
0.5
0.75
1
1.25
1.5
1.75
2
2.25
2.5
2.75
3

DESIGN SHEAR STRENGTH OF CONCRETE Tc N/mm2


M15
M20
M25
M30
M35
M40 & ABOVE
15
20
25
30
35
40
0.280
0.280
0.290
0.290
0.290
0.300
0.350
0.360
0.360
0.370
0.370
0.380
0.460
0.480
0.490
0.500
0.500
0.510
0.540
0.560
0.570
0.590
0.590
0.600
0.600
0.620
0.640
0.660
0.670
0.680
0.640
0.670
0.700
0.710
0.730
0.740
0.680
0.720
0.740
0.760
0.780
0.790
0.710
0.750
0.780
0.800
0.820
0.840
0.710
0.790
0.820
0.840
0.860
0.880
0.710
0.810
0.850
0.880
0.900
0.920
0.710
0.820
0.880
0.910
0.930
0.950
0.710
0.820
0.900
0.940
0.960
0.980
0.710
0.820
0.920
0.960
0.990
1.010

M40 & ABOVE

fdn

COLUMN

F1
F1
F3
F3
F3
F3
F3
F3
F4
F4
F3
F5
F5
F6
F1
F2
F3
F3
F3
F3
F3
F3
F4
F4
F3
F5
F5
F6
F7
F8
F7
F10
F10
F10
F10
F9
F9

C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
SC1
SC2
SC3
SC4
SC5
SC6

LENGTH
L
2800
2750
3300
3300
3300
3300
3300
3300
3800
3800
3300
3000
3000
3100
2800
2750
3300
3300
3300
3300
3300
3300
3800
3800
3300
3000
3000
3100
3000
3000
3000
2200
2200
2200
2200
2000
2000

FOOTING SIZE
WIDTH
DEPTH
B
D1
D2
3900
200
600
4600
200
600
4600
200
600
4600
200
600
4600
200
600
4600
200
600
4600
200
600
4600
200
600
4700
200
600
4700
200
600
4600
200
600
4200
200
600
4200
200
600
3100
200
500
3900
200
600
4600
200
600
4600
200
600
4600
200
600
4600
200
600
4600
200
600
4600
200
600
4600
200
600
4700
200
600
4700
200
600
4600
200
600
4200
200
600
4200
200
600
3100
200
500
3600
200
600
4000
200
600
3600
200
600
2200
500
500
2200
500
500
2200
500
500
2200
500
500
3000
500
500
3000
500
500

REINFORCEMENT
TOP STEEL
BOTTOM STEEL
ALONG L & ALONG B
ALONG L & ALONG B
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 16 mm dia Bars @ 170 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 100 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 180 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 170 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 165 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 160 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 165 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 175 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 155 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 170 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 170 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 16 mm dia Bars @ 130 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 16 mm dia Bars @ 140 mm spacing bothways
Provide 12 mm dia Bars @ 220 mm spacing bothways
Provide 16 mm dia Bars @ 225 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 16 mm dia Bars @ 170 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 160 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 175 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 175 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 165 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 160 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 165 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 175 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 165 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 160 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 175 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 16 mm dia Bars @ 135 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 16 mm dia Bars @ 145 mm spacing bothways
Provide 12 mm dia Bars @ 220 mm spacing bothways
Provide 16 mm dia Bars @ 195 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 16 mm dia Bars @ 150 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 20 mm dia Bars @ 125 mm spacing bothways
Provide 12 mm dia Bars @ 175 mm spacing bothways
Provide 16 mm dia Bars @ 140 mm spacing bothways
Provide 12 mm dia Bars @ 220 mm spacing bothways
Provide 16 mm dia Bars @ 235 mm spacing bothways
Provide 12 mm dia Bars @ 220 mm spacing bothways
Provide 16 mm dia Bars @ 235 mm spacing bothways
Provide 12 mm dia Bars @ 220 mm spacing bothways
Provide 16 mm dia Bars @ 235 mm spacing bothways
Provide 12 mm dia Bars @ 220 mm spacing bothways
Provide 16 mm dia Bars @ 235 mm spacing bothways
Provide 12 mm dia Bars @ 220 mm spacing bothways
Provide 16 mm dia Bars @ 215 mm spacing bothways
Provide 12 mm dia Bars @ 220 mm spacing bothways
Provide 16 mm dia Bars @ 235 mm spacing bothways

Das könnte Ihnen auch gefallen