CAPACITORS.
Now a days there is increasing awareness about saving energy, utilising the
available energy efficiently by employing energy efficient devices. Thus, there is
a trend to convert conventional systems to energy efficient systems.
Capacitor, which improves the power factor of the system, forms an integral part
of the energy efficient system.
Industry is rapidly changing over to energy efficient drives, devices these are
listed as below.
1. DC drives.
2. Variable speed AC drives.
3. Energy efficient lamps.
4. UPS.
etc.
Though these devices facilitate the use of energy efficiently they reduce the
power factor of the system, inject harmonics in the system. These problems
further gives rise to another problems and ultimately there is reduction in the
overall efficiency of the system.
1. DC drives :
DC drives are used as they give better efficiency than that of AC drives also the
speed control of DC drive is easy.
AC------> Converter------> DC
2. Frequency converters :
These are used to control the speed of AC drives. First AC supply is converted
into DC supply, which is again converted into AC with different frequency. This
also reduces the power factor and introduces harmonics.
AC(50 Hz) ------> DC(Using Converter) ------> AC (Using Inverter) (Variable
frequency)
3. Electronic items :
For accurate and automatic control there is increase in use of electronic controls,
also use of computers has been increased. All these electronic items require
switched mode power supply, which draws current over a part of each half cycle
as shown. This reduces the power factor.
All these devices form what is called as nonlinear load, which not
only causes the problem of low power factor but also problem of
harmonics.
A. POWER FACTOR CONTROL :
• Following tables and illustrations will enable you to properly select the
capacitor for your installation.
Existing
Factor
Then Capacitor KVAR/Load Kws ratio from the above table is 0.685.
Therefore Capacitors required are 131 x 0.685 = 89.735 KVAR.
The Capacitors are rated at 440 volts to allow for high voltages prevailing
on the systems. But they operate let us say at an average of 400 volts.
Therefore an upward revision by 1.21 times is called for. The customer
will require 1.21 x 89.74 = 108.6 KVAR. Choose 110 KVAR, which comes
within standard sizes.
We should not install more KVAR also we should not install less
KVAR than the required KVAR as both give disadvantages,
secondly we should decide optimum location of capacitors, it is
preferable to install the capacitors as near to the load as possible.
Further if there is wide variation in the load pattern we should go
for automatic power factor control method in which capacitors are
switched ON/OFF according to the load.
A. HARMONICS CONTROL :
A normal power factor correction bank is divided into two parts. One is
normal power factor correction bank, only for power factor correction
purpose and second is harmonic filter bank, which besides reducing the
harmonics also improves the power factor.
Now a days there is increasing awareness about the harmonics and its
control. Although, presently there is no legislation to control the level of
harmonics it will be introduced in near future and the consumer which is
generating harmonics beyond specified limits may have to pay penalty.
There are standards like IEEE 519-1992, which recommends limits on the
voltage and current distortion. CBIP has also taken steps in this direction
and has published a guide for limiting voltage harmonics while guide for
limiting current harmonics is in pipe line. Also current distortions limits
are gaining increasing importance over the voltage distortion limits.
Table 1 Current distortion limits for general distribution systems.
The IEEE standard 519 specifies voltage distortion limits as per the table
below.
Bus voltage at PCC Individual voltage Total voltage
distortion % distortion THD %
Following example gives general idea and values for harmonic filter.
Data :
By calculation :
Thus,
(It can be seen that individual rating of reactor and capacitor is quite high.)
The cost of harmonic filter is many times the normal capacitor bank but the
advantages gained are worth.
In near future all conventional drives will be replaced by energy efficient drives ,
which brings along with it the problems of low power factor and harmonics.
These problems can be easily solved by using capacitors and total system can be
made more energy efficient.