Insulation

First Issue December 2011

TR27 FM Roofboard
INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE-PLY, PARTIALLY BONDED BUILT-UP FELT, MASTIC ASPHALT AND COLD LIQUID APPLIED WATERPROOFING

High performance rigid thermoset insulation thermal conductivities as low as 0,025 W/m.K FM approved for Class 1 steel deck roof assemblies Compatible with most green roofing systems Resistant to the passage of water vapour Easy to handle and install Ideal for new build and refurbishment Nondeleterious material Manufactured with a blowing agent that has zero ODP and low GWP

G G G G G G G

Class 1 Roof Construction

Kingspan
Description
Kingspan Therma TR27 FM comprises a high performance rigid thermoset polyisocyanurate (PIR) insulation core, faced on both sides with a coated glass tissue based facing, autohesively bonded to the insulation core during manufacture.

TR27 FM
Product Data
Property Result General Refer to local distributor for current stock and nonstock sizes Board Length (mm) 2400 1200 Board Width (mm) 1200 600 Compressive Strength Typically exceeds 150 kPa (EN 826) @ 10% compression Dimensional Stability - 48 Hours 2% (70C & 90% RH (EN 1604) length & breadth) 6% (70C & 90% RH thickness) Diffusion Resistance Factor 60 Thermal Thermal Conductivity (EN 13165) 0,027 W/m.K (thickness < 80) 0,026 W/m.K (thickness 80 119 mm) 0,025 W/m.K (thickness 120 mm) Fire Reaction to Fire (EN 13501) External Flame Spread (ENV 1187) Resistance to Fire (EN 1363-1), (EN 1363-2), (EN 1365-2) E (tested as placed on market) Bs3d0* (tested in application) BROOF (t2)** 32 minutes integrity*** Product Thickness

General
Resistance to Solvents, Fungi & Rodents The insulation core is resistant to shortterm contact with petrol and with most dilute acids, alkalis and mineral oils. However, it is recommended that any spills be cleaned off fully before the boards are installed. Ensure that safe methods of cleaning are used, as recommended by suppliers of the spilt liquid. The insulation core is not resistant to some solvent based adhesive systems, particularly those containing methyl ethyl ketone. Adhesives containing such solvents should not be used in association with this product. Damaged boards or boards that have been in contact with harsh solvents or acids should not be used. Cutting Cutting should be carried out by using a fine toothed saw. Ensure accurate trimming to achieve closebutting joints and continuity of insulation. Daily Working Practice At the completion of each days work, or whenever work is interrupted for extended periods of time, a night joint must be made in order to prevent water penetration into the roof construction. Packaging and Storage The polyethylene packaging of Kingspan Insulation products, which is recyclable, should not be considered adequate for outdoor protection. Ideally, boards should be stored inside a building. If, however, outside storage cannot be avoided, then the boards should be stacked clear of the ground and covered with an opaque polythene sheet or weatherproof tarpaulin. Boards that have been allowed to get wet should not be used. Health and Safety Kingspan Insulation products are chemically inert and safe to use. A Safety Information Data Sheet for this product is available from the Kingspan Insulation website.
Warning do not stand on or otherwise support your weight on this product unless it is fully supported by a load bearing surface.

*Has achieved this result when tested in accordance with EN 13165/A2: 2005 and EN 15715: 2007 as part of a construction consisting of the Kingspan Therma TR27 FM screwed to a 34/1035 steel deck and backed by a calcium silicate board. In the steel deck a vertical joint at 200 mm was applied. The steel deck side was exposed to the fire. **Has achieved this result when tested as part of a construction consisting of a 1.2 mm polyester reinforced PVC-foil membrane applied to 50 mm of Kingspan Therma TR27 FM. Please note that actual performance is dependant the single-ply membrane adopted and should be verified with the Kingspan Insulation Technical Service Department. ***Has achieved this result when tested as part of a composite steel roof construction consisting of: 0.75 mm trapezoidal steel sheets fixed together with 4.8 mm x 16 mm self-drilling screws at 250 mm centres; a 0.2 mm thick polyethylene vapour barrier foil; two layers of 55 mm Kingspan Therma TR27 FM; and a 1.2 mm thick PVC waterproofing membrane.
TM TM TM

Standards & Approvals


Kingspan Therma TR27 FM is manufactured to the highest standards under a management system certified to BS EN ISO 9001: 2008 (Quality Management Systems. Requirements), BS EN ISO 14001: 2004 (Environmental Management Systems. Requirements) and BS OHSAS 18001: 2007 (Health & Safety Management Systems. Requirements).

FM & LPCB Certification


The product is certified as achieving Class 1 Insulated Steel Deck Pass to FM research standards 4450: 1989 and 4470: 2010, subject to the conditions of approval as a roof construction for use in Class 1 roof constructions as described in the current edition of the FM Research Approval Guide. Metal deck roofing constructions, incorporating a sealed metal deck or a separate vapour control layer and 30-120 mm of the product in a single layer, have been successfully tested to LPS 1181: Part 1, achieving an EXT B rating. For further details, please search for approval reference number 388b/02 on www.redbooklive.com.

Kingspan Insulation B.V.


Lorentzstraat 1, 7102 JH, Winterswijk, Netherlands Tel: +31 (0) 543 543 210 Fax: +31 (0) 344 675 215 email: info@kingspaninsulation.eu Technical Advice Tel: 00800 Kingspan (00800 54647726) Fax: +31 (0) 344 675 215 email: technical@kingspaninsulation.eu

www.kingspaninsulation.eu
Kingspan and the Lion Device are Registered Trademarks of the Kingspan Group plc in the EU and other countries. All rights reserved. Therma is a Trademark of the Kingspan Group plc. Registered in Netherlands No. 11 053 542. Registered Office: Kingspan Insulation B.V., Winterswijk, NL. VAT NL 81 09 09 881 B01