A-class energy performance in cooling and heating operations. Thanks to XPower Plus technology, the systems seasonal efficiency is extremely high. Guaranteed cooling operation from 15C to +46C outdoor temperature. Heating performance even at 15C outdoor temperature. Suitable for applications that require up to 70m distance between the indoor and the outdoor unit. Ultra-slim profile only 290mm for all models, thanks to the Carrier-patented V-shaped coil. Designed for front or side air discharge. Thanks to the modular filter and panel sizes, the unit is flexible and can be mounted with rear or base air return. Equipped with pre-punched 150mm diameter fresh air intakes on both sides, and with pre-punched Octopus discharge panel. Control box is equipped with 1,5m cable for flexible positioning and accessibility.
Indoor unit Outdoor unit (HP) Nominal cooling capacity Minimum cooling capacity Maximum cooling capacity Nominal power input E.E.R. Energy efficiency class Annual energy consumption Nominal heating capacity Minimum heating capacity Maximum heating capacity Nominal power input C.O.P. Energy efficiency class Indoor unit Dehumidification Nominal air flow (l/m/h) Nominal static pressure Sound pressure (l/m/h) Sound power (l/m/h) Sound pressure (l/m/h) Sound power (l/m/h) Dimensions (h l d) Weight Power supply Outdoor unit (HP) Compressor type Maximum pipe length Maximum height difference Chargeless Air flow (max) Air flow (max) Sound pressure Sound power Sound pressure Sound power Dimensions (h l d) Weight Flare connections Power supply CO CO HP HP m m m l/sec m3/h dB(A) dB(A) dB(A) dB(A) mm kg in V-ph-Hz CO CO HP HP CO l/h l/s Pa dB(A) dB(A) dB(A) dB(A) mm kg V-ph-Hz CO CO CO CO CO CO CO HP HP HP HP HP HP kWh kW kW kW W W/W kW kW kW W W/W
40XPD050 38XPS050H7 5,00 0,77 5,77 1557 3,21 A 779 5,50 0,86 6,44 1523 3,61 A 40XPD050 1,6 210/263/290 50 39/40/42 52/53/55 39/40/42 52/53/55 925 750 290 32 230-1-50 38XPS050H7 twin rotary 50 30 20 728 2620 44 64 44 64 690 900 320 49 1/4 1/2 230-1-50
40XPD070 38XPS065H7 6,60 0,85 7,01 2055 3,21 A 1028 7,00 0,85 8,88 1940 3,61 A 40XPD070 2,5 205/211/269 50 38/40/42 51/53/55 38/40/42 51/53/55 925 750 290 35 230-1-50 38XPS065H7 twin rotary 30 30 20 783 2820 45 65 48 68 820 900 320 51 3/8 5/8 230-1-50
40XPD070 38XPS070H7 7,00 1,81 8,32 2180 3,21 A 1090 7,20 1,83 8,54 1995 3,61 A 40XPD070 2,6 205/211/269 50 38/40/42 51/53/55 38/40/42 51/53/55 925 750 290 35 230-1-50 38XPS070H7 twin rotary 50 30 20 742 2670 45 65 48 68 820 900 320 73 3/8 5/8 230-1-50
40XPD100S 38XPS100H7 10,00 3,40 12,50 3115 3,21 A 1558 10,40 3,39 13,11 3050 3,41 B 40XPD100S 4,1 296/356/396 50 39/42/45 52/55/58 39/42/45 52/55/58 925 750 290 49 230-1-50 38XPS100H7 twin rotary 70 30 30 1658 5970 48 68 49 69 1360 900 320 73 3/8 - 5/8 230-1-50
40XPD100 38XPS100H7 10,00 3,40 12,50 3120 3,21 A 1560 11,00 3,59 13,87 3050 3,61 A 40XPD100 3,3 390/476/564 80 44/46/49 57/59/62 44/46/49 57/59/62 1325 750 290 48 230-1-50 38XPS100H7 twin rotary 70 30 30 1658 5970 48 68 49 69 1360 900 320 88 3/8 5/8 230-1-50
40XPD125 38XPS125H7 12,50 3,41 14,70 4153 3,01 n.a. 13,10 3,70 16,06 3742 3,50 n.a. 40XPD125 3,8 569/616/667 80 47/51/54 60/64/67 47/51/54 60/64/67 1325 750 290 53 230-1-50 38XPS125H7 twin rotary 70 30 30 1767 6360 50 70 50 70 1360 900 320 88 3/8 5/8 230-1-50
Ovlasten distributer:
ENERGIJA doo
Londonska 1B, 1000 Skopje, R. Makedonija Tel: (02) 3061 466 (02) 3061 467 Faks: (02) 3061 468 info@energija.com.mk www.energija.com.mk
www.carrier.com
GB_Satellite 28 GENN.qxd
27-01-2005
17:10
Pagina 22
24 28 46 40SMC009N 40SMC012N 40DMC018 38BC-009G 38BC-012G 38GL-018G 2,71( 2331 ) 3,41 ( 2933 ) 5,40 ( 4644 ) 1030 1250 2151 2,63 2,73 2,51 D D E 515 625 1075 38BH-009G 38BH-012G 38YY-018G 2,64 ( 2270 ) 950 2,78 D 475 3,20 ( 2752 ) 980 3,27 C 3,35 ( 2881 ) 1170 2,86 C 585 3,76 ( 3234 ) 1250 3,01 D 5,42 ( 4661 ) 2038 2,66 D 1019 5,64 ( 4850 ) 1828 3,09 D
60 40DMC024 38GL-024G 6,48 ( 5573 ) 2763 2,34 F 1381 38YY-024G 6,63 ( 5702 ) 2458 2,7 D 1229 7,02 ( 6037 ) 2444 2,87 D 40DMC024 2,00 50 38/40/42/43 51/53/55/56
285x925x750
74 40DMC028 38GL-028G 7,84 ( 6742 ) 2947 2,66 D 1474 38YY028G 7,70 ( 6622 ) 2947 2,61 D 1474 8,23 ( 7078 ) 2468 3,33 C 40DMC028 2,31 50 40/43/46/48 53/56/59/61 35 230-1-50 38GL-028G 38YY-028G
40
140 150 40DMC052 40DMC060 38GL-052G9 38GL-060G9 11,55 ( 9933 ) 13,49 ( 11601 ) 3830 4797 3,01 2,81 B 1915 38YY-052G9 38YY-060G9
8,79 ( 7560 ) 10,14 ( 8720 ) 12,03 ( 10346 ) 13,77 ( 11482 ) 3376 3461 4282 5041 2,61 2,93 2,81 2,73 D C 1688 1730 9,14 ( 7860 ) 10,99 ( 9451 ) 13,28 ( 11421 ) 14,50 ( 12470 ) 2702 3367 4166 4110 3,38 3,26 3,19 3,53 C C 40DMC036 2,01 80 44/46/49/50 57/59/62/63 48 230-1-50 38GL-036G 38YY-036G
40/50*
40DMC036
33 39/40/41/42 55/56/57/58
220x725x555
40 40/41/42/43 56/57/58/59
220x725x555
50 39/40/42/43 52/53/55/56
285x925x750
m m3/h
dB(A) dB(A)
15 25 8 8 1900/2600 2400/2400 45/48 48/48 65/68 68/68 590x800x300 590x800x300 803x800x300 803x800x300 45/47 51/60 65/67 1/2" - 1/4" 1/2" - 1/4" 5/8" - 1/4" 230-1-50 230-1-50
230-1-50/ 400-3-50
Cooling capacity is based on: indoor air temperature 27C dry bulb / 19C wet bulb, outdoor air temeprature 35C dry bulb / 24C wet bulb Heating capacity is based on: indoor air temperature 20C dry bulb / 15C wet bulb, outdoor air temperature 7C dry bulb / 6C wet bulb Sizes 40SMC009/012 hadnt been changed and has the same values as the series Teide Eco 2004 (*) Monophase/ Tri phase (1) Sound pressure level in anechoic room at 1,28 m from discharge outlet on vertical wall (2) Sound pressure level in emispheric field at 4 m The indicated capacities for size from 24 to 120 represent the mono phase versions. Please check the technical manual for the three phase versions.
DUCTED UNIT
RLCSAT2A20E-11/04-Copistampa
www.carrier.com
40DMC 40DQV
TECHNICAL DATA
GB_Satellite 28 GENN.qxd
27-01-2005
17:10
Pagina 2
GB_Satellite 28 GENN.qxd
27-01-2005
17:10
Pagina 4
Everything!
The slimmest unit in its class The lightest unit in the range Fits into even the smallest spaces Universal and adaptable to any pipe routing Exceptionally versatile Removable control box Rear connections External air intake Simple maintenance Infrared remote control Wired control
GB_Satellite 28 GENN.qxd
27-01-2005
17:10
Pagina 6
V as in VERY USER-FRIENDLY: The Satellite offers three main user benefits: - Easy to install - Available in a wide model range - Exceptionally quiet
V as in VERY VERSATILE: The Satellite can be installed anywhere easily. With its special new design and features it is extremely flexible and suits every type of environment.
GB_Satellite 28 GENN.qxd
27-01-2005
17:10
Pagina 8
It is the slimmest unit in its class: only 285 mm for the whole range
Optimised size reduction: only 285 mm high!! Ideal for installations where ceilings are very low, suits every project.
2
285 mm
Comparison:
BRAND A BRAND B BRAND C
Comparison:
BRAND A BRAND B BRAND C
350
with the same capacity with the same capacity
285
the whole range
285
small frame
325
300
the whole range
299
up to small frame large frame
+35%
up to
up to
+40%
large frame
+17%
expressed in mm
GB_Satellite 28 GENN.qxd
27-01-2005
17:10
Pagina 10
Ultimate versatility
The Satellite unit can be also be installed against the wall with either side or bottom air return. Just remove panel and filter and re-locate them as required.
The Carrier Satellite needs no accessories to install the ducts. The unit incorporates a flange to accept also rectangular ducts.
But thats not all. The Carrier Satellite can also be installed in a corridor. In addition to front air supply, two pre-punched knockout holes allow side connection of the air duct.
The unit is also provided with an octopus panel with pre-punched knockout holes for connection of circular ducts. With side air supply this panel is used to close off the front.
GB_Satellite 28 GENN.qxd
27-01-2005
17:10
Pagina 12
Rear connection
Simple maintenance
The control box is fitted to the outdoor unit. It includes a 1.5-m cable allowing the installer to remove it and position it in a more convenient place, if required.
To fully exploit the available space refrigerant and condensate connections are at the rear. As requested by our installers a 20-mm flexible hose was inserted at the rear of the unit to allow condensate drainage as required.
A pre-punched 150 mm wide rectangular fresh air intake hole is provided at the side for both frame sizes.
Filter replacement from below is easy, and motor and fan can be accessed by simply by removing the bottom panel.
GB_Satellite 28 GENN.qxd
27-01-2005
17:10
Pagina 14
Wired controls
As an alternative to the infrared remote control, the Carrier Satellite can be controlled by a user-friendly wired control system
Room Controller
33MC-RC
1 zone x 6 units
The MyComfort kit includes receiver, remote control, T connector to link two indoor units and 15 metres of cable
My Comfort
With MyComfort you can memorise your individual comfort settings for personalised well-being 33MC-IS
Zone Manager
33MC-ZM
Daily timer
Timer settings are repeated for every day
GB_Satellite 28 GENN.qxd
27-01-2005
17:10
Pagina 16
ING TIM E
85%
EER > 3,20
The Carrier Satellite is also available as a high-performance XPower version. Thanks to its high efficiency only four models cover the wide application requirements from 1.5 kW to 13 kW.
Tests carried out in applications around the world demonstrate that XPower systems perform at exceptionally high efficiency levels for 85% of the operating time. In these conditions the XPower compressors absorb only a small amount of energy, reducing annual electricity bills by 40%.
The Carrier Satellite is also available as an Experience version, with seven combinations covering all market requirements for both range and capacity size intervals.
OTHER BRANDS
OTHER BRANDS
RATED CAPACITY
7 kW 12 kW 59 62
BRAND B
60 63
RATED CAPACITY
7 kW 12 kW 53 62
BRAND A
64 71
BRAND B
60 62
BRAND C
65 65
*brands of equal capacity, the noise level was measured according to Eurovent 2004
*brands of equal capacity, the noise level was measured according to Eurovent 2004
The Carrier XPower Satellite also sets new standards for low noise levels in this class. The units are exceptionally quiet and efficient, the ideal choice for optimal comfort conditions.
The new XPower models are available from June 2005
The Carrier Satellite Experience is the benchmark unit for low noise levels in its class.
GB_Satellite 28 GENN.qxd
27-01-2005
17:10
Pagina 18