Sie sind auf Seite 1von 7

Installation and Assembly - All-in-one Projector Adapter Plate for

InFocus Projectors
R

Models: SP-CEIL-011

This product is intended for use with UL Listed products and must be installed by a qualified professional installer.

Maximum Load Capacity: 50 lb (27 kg)

Read instruction sheet before you start installation and assembly. Installer must verify that the ceiling will safely support

WARNING the combined weight of projector mount and projector.


IMPORTANT! Be sure not to touch the projector while tightening the set screw on the ball and socket mount. This may cause the image to be unaligned when you let go. IMPORTANT! Turn to the appropriate page for your ceiling installation.
Installations: Flush Mount ......................................................................................................................................... step 1, page 3 Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings .............................................................................. step 2, page 3 Concrete Ceilings ............................................................................................................................................ page 4 Extension Columns ......................................................................................................................................... page 5

SET SCREW

1 of 7
Visit the InFocus Web Site at www.infocus.com

ISSUED: 1-5-04 SHEET #: 055-9196-1

Before you start check the parts list to insure all of the parts shown are included.

Parts List
Description A B C D E F G H I J K L M N O P ball and socket mount 4 mm security allen wrench M5 x .8 x 10 mm socket pin type F screw #10-32 x 3/8 spade thumb screw #10-32 x 3/8 serrated washer head socket pin screw #14 x 2.5 phillips hex head wood screw ceiling plate .25" ID x .56" OD x .26 spacer extension column connector 10-32 x 3/8 socket pin screw 10-32 x 3/16 slotted set screw adapter plate M4 x 16 mm serrated washer head socket pin screw M4 x 12 mm serrated washer head socket pin screw .198 x .313 x .375 retaining spacer .198 x .313 x .187 retaining spacer Qty. 1 1 1 1 1 2 1 2 1 2 1 1 3 1 3 1 Part Number 055-0011 560-9646 520-1164 560-1107 520-1151 5S1-015-C03 580-1042 590-1050 580-1013 520-1084 520-1187 055-1445 510-1087 510-1079 590-2020 590-1030

C A I M

J N K

E D

H O P

G .ASTENERS
2 of 7
Visit the InFocus Web Site at www.infocus.com

Note: Actual parts may appear slightly different than illustrated.

ISSUED: 1-5-04 SHEET #: 055-9196-1

.lush Mount Installation


Screw ball and socket mount (A) into ceiling plate (G). Align the notch with one of the four holes of the ceiling plate (G) and secure ball and socket mount (A) with a M5 x 10 mm socket pin screw (C) using security allen wrench (B) as shown in detail 1. Note: Slotted set screw (K) is used to jam against the threads of the ball and socket mount to prevent any excess movement of the ball and socket mount (A). Do not over-tighten screw; over-tightening screw will damage threads making it difficult to separate the products.

NOTCH

Skip to step 5.
WOOD JOIST

C A G

CEILING

G
DETAIL 1

A Installation To Wood Joist .inished Ceilings, Exposed Wood Joists, WOOD or Wood Beam Ceilings JOIST
Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (G) with two #14 x 2.5" (6 mm x 65 mm) wood screws (F) as shown using 3/8" (10 mm) socket wrench. Tighten wood screws (F) so ceiling plate (G) is firmly attached. DO NOT TIGHTEN WITH EXCESSIVE FORCE! Over-tightening can cause stress damage to wood screws (F) greatly reducing their holding power! Tighten to 80 in lb (9 N.M.) maximum torque. Skip to step 5. WARNING: It is the responsibility of the installer to verify that the ceiling will safely support the combined load of all attached hardware and components. IMPORTANT: Be sure to drill holes into the joist CENTER!
CEILING

F F
For Optional Cord Management, install two spacers (H) between ceiling plate (G) and ceiling.
3 of 7

ISSUED: 1-5-04 SHEET #: 055-9196-1

Visit the InFocus Web Site at www.infocus.com

Installation to Concrete Ceilings


Alligator concrete anchors are recommended. Drill two 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (G) using two concrete anchors and #14 x 2.5" wood screws (F) as shown in Illustration A and 1, 2, and 3 (below). Tighten all fasteners. Skip to step 5. IMPORTANT: It is the responsibility of the installer to verify that the ceiling will safely support the combined load of all attached hardware and components. CAUTION: Tighten wood screws so ceiling plate (G) is firmly attached. DO NOT TIGHTEN WITH EXCESSIVE FORCE! Over-tightening can cause stress damage to wood screws, greatly reducing their holding power! Tighten to 80 in lb (9 N.M.) maximum torque.
concrete anchor

CONCRETE CEILING

G
1
concrete ceiling

concrete anchor

F
Illustration A
FOR DIRECT ATTACHMENT TO LOAD BEARING CONCRETE ONLY! Concrete expansion anchors are not intended for attachment to concrete ceilings covered with a layer of plaster, drywall, or other finishing material. If mounting to concrete ceiling covered with plaster / drywall is unavoidable, plaster / drywall must be counterbored as shown below.
INCORRECT
CUTAWAY VIEW
metal bracket concrete metal bracket

Drill hole and insert anchor

G F
concrete anchor

Place ceiling plate over anchor and secure with screw

CORRECT
concrete

concrete anchor

plaster/ dry wall

plaster/ dry wall

After repeating step one tighten all fasteners

4 of 7
Visit the InFocus Web Site at www.infocus.com

ISSUED: 1-5-04 SHEET #: 055-9196-1

Installation to Extension Column


Screw extension column to ceiling plate (G). Align the notch with one of the four holes in the ceiling plate (G) and secure extension column with a M5 x 10 mm socket pin screw (C) using security allen wrench (B). See detail 3. Screw extension column connector (I) to extension column. Align slot in extension column with one of the top holes in extension column connector (I). Insert and tighten one 10-32 x 3/8 socket pin screw (J) through extension column connector (I) into slot on extension column using security allen wrench (B). See detail 4. Screw ball and socket mount (A) to extension column connector (I). Align slot in ball and socket mount (A) to one of the bottom holes in extension column connector (I). Insert and tighten one 10-32 x 3/8 socket pin screw (J) through extension column connector into slot in ball and socket mount (A) using security allen wrench (B). Note: Slotted set screw (K) is used to jam against the threads of the ball and socket mount to prevent any excess movement of the ball and socket mount (A). Do not overtighten screw; over- tightening screw will damage threads making it difficult to separate the products.

C G

EXTENSION COLUMN (SOLD SEPARATELY)

EXTENSION COLUMN

SLOT

DETAIL 3

EXTENSION COLUMN

I
SLOT

SLOT

I J
DETAIL 4

EXTENSION COLUMN

I K A
SLOT

J
DETAIL 6

5 of 7
Visit the InFocus Web Site at www.infocus.com

ISSUED: 1-5-04 SHEET #: 055-9196-1

Flip projector upside down. Find your projector from the models listed below. Using the holes indicated on the corresponding hole pattern diagram, attach adapter plate (L) to projector using three M4 x 16 mm serrated washer head socket pin screws (M) and three .198 x .313 x .375 retaining spacers (O). Notes: Retaining spacers go between adapter plate and projector. * Notch indicates front of projector. ** Projectors using hole pattern G use one M4 x 12 mm screw (N) and one .198 x .313 x .187 retaining spacer (P) where indicated. A. C200, C420, DP6500X, DP8200X, LP650, LP820, SP7200, SP7205 B. C40, C50, DP2000S/X, LP240, LP250 C. LP340, LP350, LP500, LP530, SP110

D. C100, C105, DP6150, DP6155, LP690

E. C110, DP8000, LP790, SP4800, SP4805, X1, X2

F. C170, LP600

G. C160, C180, LP540, LP640

**

6 of 7
Visit the InFocus Web Site at www.infocus.com

ISSUED: 1-5-04 SHEET #: 055-9196-1

Note: The projector you are installing may differ in appearance from the sample illustrated below. Attach projector to the ball and socket mount (A) by inserting the ball and socket mount (A) into the adapter plate connection and twisting until the adapter plate will no longer turn (about 75). The spring loaded captive screw should line up with a corresponding hole on the adapter plate (this should line up automatically when the two are connected). Push down and tighten the spring loaded captive screw to secure the adapter plate to the mount. If not using the optional security feature, fasten thumb screw (D) in the hole opposite the spring loaded captive screw. OPTIONAL: For Armor Lock security, insert serrated washer head socket pin security screw (E) in the hole opposite the spring loaded captive screw. Tighten with security allen wrench (B). This will prevent the projector from being removed. Note: Be sure to only use the 10-32 x 3/8" screw (E) (or the thumb screw (D)) opposite the spring loaded captive screw. To adjust roll, pitch, and yaw loosen the set screw (shown below) using security allen wrench (B) or standard 4 mm allen wrench. You should be able to just slightly loosen the screw so that your adjustments can be set without having to hold the projector. Move projector to desired position and slowly tighten set screw. Note: Be sure not to touch the projector while tightening the set screw. This may cause the image to be unaligned when you let go. IMPORTANT: Allen wrench is your key for projector removal. Store it in a safe place.

WOOD JOIST

CEILING CEILING

E
WOOD JOIST CAPTIVE SCREW

SET SCREW

D
PROJECTOR

2 1
PROJECTOR ADAPTER PLATE

PROJECTOR

WARNING: Do not lift more weight than you can handle! Use additional man power or mechanical lifting equipment to safely handle placement of the projector! 7 of 7
Visit the InFocus Web Site at www.infocus.com
2004 Peerless Industries, Inc. All rights reserved. Peerless is a registered trademark and Armor Lock is a trademark of Peerless Industries Inc. All other brand and product names are trademarks or registered trademarks of their respective owners.

ISSUED: 1-5-04 SHEET #: 055-9196-1

Das könnte Ihnen auch gefallen