Beruflich Dokumente
Kultur Dokumente
Service Manual
Features
Class AAB 1 to 6kg self-selected washing laundry for certain quantity Intelligence memory for the washing habit of its consumer 320mm extraordinary porthole 42personalized tilted control panel 100mm extraordinary colour display Childrens safe lock Scheduled washing function in 24 hrs Spin speed 1200/1000 rpm
Haier Group
MANUAL CODEHT1206TXVE-00-RUSSIA
Edition :2005.06.01
Contents
1Contents----------------------------------------------------------------------------------------2 2 Product model illumination -----------------------------------------------------------------3 3Specification ---------------------------------------------------------------------------------4 4Safety caution -------------------------------------------------------------------------------6 5Installation ------------------------------------------------------------------------------------9 6Functions -------------------------------------------------------------------------------------11 7Function schedule-------------------------------------------------------------------------13 8Trouble shooting----------------------------------------------------------------------------15 9Wiring circuit --------------------------------------------------------------------------------19 10Exploded view and list of parts--------------------------------------------------------20
Product model illumination Model code rule description Model identification HT 120 6 T X V E
A B CD E FG
ASerial code-HT Series BMax spin speed-1200rpm CMax wash load-6kg DTemprature adjustive EStainless steel tub FSpin speed adjustive GComputer control
Examples HT1206TXVE
It represents computer control washing machine with HT series appearancewith 320mm big window180opening window1200rpm spin speed6kg max.wash loadspin speed is adjustive from 400 to 1200rpmtemprature is also adjustive from *to 90 and outer tub is stainless steel material.
Specification
Product identification Description of appliance Type of appliance (FS = standing, BI = built-in Supplier own brand Supplier bar code Commercial Brand / Model Commercial bar code Key-Features Energy efficiency class Washing performance class Spin efficiency class Programs Capacity Spin speed (max. / optional) Noise level Energy consumption per wash circle Water consumption per wash cycle Annual average energy consumption * Annual average water consumption* Residual dampness (spin result) Spin speed selector switch (steps) Spin speed variator (steps) Adjustable thermostat (water temp. adjust from - to) Drum capacity dry laundry / water Auto water level adjust (depending on volume of filled in laundry) Washing temperatures (program-controlled) Certification's (CE / ISO 9001 / ISO 9002) Approvals (VDE/GS / TV/GS / IMQ) * per average 200 wash cycles (EN50242) = COLD Basics data Unit dimensions (H x W x D) Net weight Voltage/frequency Input power / main fuse (intensity) Work top / removable Control M = electromechanical, E = electronic, F = fuzzy Drum S = stainless steel / Z = zinc coated Tub P = Polyprop./ S = stainless steel Door: aesthetic (R = round, Y = big eye, Q = square) Diameter Outer door frameS= stainless steel / M = metal / P = plastic Inner door G= glass / P= plastic Detergent compartments Delay timer (from - to,Endzeitvorwahl) Self cleaning suds pump Water inlet hose cold water / hot water Water drain Adjustable feet hose / -support n Washing machine FS Haier EAN EAN Haier TBC A A B 11 Max. 6 1200,1000,800,600,400-0 69.5 1.12 52 224 10400 52.4% 90 6 /46 40 / 60 /75/90 CE / ISO 9001 TV/GS (Rhl.)
cm kg V/Hz W/A
cm
n h
Specification
Safety systems Auto door lock Motor overheating protection No heating without water Auto water cool-down (before drain 90C boiled water) Water return protection Acqua Stop kit Safe button Programs 1) Cotton (90C/75C/60C/40C/) 2) Synthetics (60C/40C/) 3) Wool (40C/) 4) Cashmere(40C/) 5) Silk(40C/) 6) Hand wash(40C/) 7) Duvet(40C/) 8) Quick wash(40C/) 9) Rinse+Spin() 10)Drain only() 11)Spin only() Optional function keys (additional program settings) Start / stop pause Load select Extra rinse program Pre-wash Delay timer Soak speed temperature Packing dimensions & loadability Packing dimensions (H x W x D) Gross weight 40' HC load capacity Built-in dimension Requested measure of niche (H x W x D) Dimensions of door Logistic / recicling information Packing weight Packing materials / Recycling symbols Carton Polystyrene Polyethylene foil Other packing materials Wood ADL MOP NHW AWC WRP -
n n n n n n n n n n n
5 3 2 2 2 2 2 2 1 1 1
cm kg pcs cm cm RS kg
gr gr gr gr kg
Safety caution
Safety caution
Safety caution
lnstallation
Installation
Functions
Functions
Function schedule
Function schedule
Troubleshooting
Troubleshooting
S/N Possible Malfunctions Possible causes Transportati on part of the 5 cable connectors
(ST4-1~ST-5)
Checking Steps 1. Eyeball whether the cable connectors are in position on the computer display board. 2. Eyeball whether the electric current breaks between cable connectors and program selecting board. 3. Eyeball whether the line connecting the program selecting board and cable connectors connecting points breaks. 1. Check the S10 and ST1 terminals on the program selecting board, X4 and X7 terminals on the power drive board, and ST3 terminal on the computer display board. 2. Check whether the back connecting points on the program selecting board are broken; measure and test whether the voltage between the two ends of ST1 is 220 V. 3. Check the whether the back connecting points on the power drive board X4 are broken; measure and test whether the voltage between X4-1 and X4-2 (or between J3 and J1 on the power board) is 220 V. 4. Measure and test the silicon control diode(1S2) pin voltage relative to the earth on the power drive boardthe left is 22V DC; the right is 5V DC. 5. Measure and test X7-4 and X7-5 terminal relative to the X7-6 voltage X7-4 is 22V DC; X 7-5 is 5V DC.
Instrument
Solutions 1. Insert and connect in position. If not, please go on with step 2. 2. If electric current is broken, change the program selecting board. If not, please go on with step 3. 3. If electric current is broken, change the program selecting board.
Time remains the same after revolving the knob; or remains the same on part programs position.
Eyeballing
Eyeballing Multimeter
Eyeballing Multimeter
Eyeballing
Eyeballing Multimeter
2. If electric current is broken, change the program selecting board. If the voltage is 220V, please go on with step 3. 3. If electric current is broken, change the power drive board; if the welding point is not broken and the voltage between J3 and J1 is not 220V, consider checking whether the wiring harness is broken; if the voltage is 220V, please go on with step 4. 4. If the voltage doesnt comply with the requirement, change power drive board; if it complies with the requirement, please go on with step 5. 5. If the voltage doesnt comply with the requirement, change power drive board; if it complies with the requirement, please go on with step 6. 6. If the voltage doesnt comply with the requirement, change the 6 connecting lines between X7 and ST3; if it complies with the requirement, please change computer display board.
Power supply cable is broken. No sound when buttons pressed; no signal on the display screen. or Damage of the electric components, such as: chips, silicon control, diode, etc.
Eyeballing Multimeter
Eyeballing Multimeter
Eyeballing Multimeter
6. Measure and test ST3-3 and ST3-2 terminal relative to the ST3-1 voltageST3-3 is 22V DC; ST3-2 is 5V DC.
Eyeballing Multimeter
Troubleshooting
S/N Possible Malfunctions VFD screen cannot fully display. Possible causes Breakdown of computer display board Checking Steps Check whether the cable is partly broken or whether there is cracked, partly burnt or etched phenomenon of all kinds of chips. Check whether computer display board in position. 4 Buttons do not work. Breakdown of computer display board Check by hand whether the buttons are comfortable to press; check whether the cables around the buttons are broken or partly burnt or etched, etc. 1 Check whether the door is well closed. 2. Check whether the door lock is well linked. 3. Check whether the door lock is damaged. Instrument Solutions
Eyeballing
Eyeballing
Breakdown of computer display board. Err1 Alarm 5 or Breakdown of power drive board.
4. Check whether the relevant wiring harness is broken. (esp. the connecting line from computer display board to power drive board as well as the lock cable. )
Eyeballing Multimeter
Err2 Alarm
The water is not drained completely (The water switch does not return to normal.)
Err3 Alarm
Err4 Alarm
1. Check whether the drainage pump is blocked. 2. Check whether the drainage pump is damaged. 3. Check whether the pressure switch hose or gas-collecting valve is blocked. 4. Check whether the pressure switch is damaged. 5. Check whether the relevant wiring harness is broken. 1. Check whether sensor is well linked. 2. Check whether temperature sensor is damaged. 3. Check whether the relevant wiring harness is broken. 1. Check whether the heating element is well linked. 2. Check whether the heating element is damaged. 3. Check whether the relevant wiring harness is broken.
Eyeballing Multimeter Check by hand Eyeballing blowing Eyeballing Multimeter Eyeballing Multimeter Eyeballing Multimeter Eyeballing Multimeter Eyeballing Multimeter Eyeballing Multimeter
If normal, go on with the next step. If normal, go on with the next step. If normal, go on with the next step. If normal, change computer display board or power drive board. Check which board goes wrong in an exchanging way. In case of Err1 Alarm, the quality computer display board and power drive board are expected to be taken before the user is served to make it easy to check. If normal, go on with the next step. If normal, go on with the next step. If normal, go on with the next step. If normal, go on with the next step. If normal, change power drive board. If normal, go on with the next step. If normal, go on with the next step. If normal, change power drive board. If normal, go on with the next step. If normal, go on with the next step. If normal, change power drive board.
Troubleshooting
S/N Possible Malfunctions Possible causes Checking Steps 1. Check whether the tap is open. 2. Check whether the water pressure is too low. 3. Check whether the electromagnetic valve is well linked. The water switch does not move within 8 minutes. 4. Check whether the pressure switch is well linked. 5. Check whether the pressure switch hose leaks gas or not. 6. Check whether the electromagnetic valve is damaged. 7. Check whether the pressure switch is damaged. 8. Check whether the relevant wiring harness is broken. 1. Check whether the motor is well linked. 10 Err6, Err7, FErr Alarm The motor is broken. 2. Check whether the motor is damaged ( or over-heated ). 3. Check whether the relevant wiring harness is broken. 1. Check whether the drainage pump is well linked. 2. Check whether the drainage pump is damaged (short circuit inside). The water level is over the protecting water level. 3. Check whether the pressure switch is well linked. 4. Check whether the pressure switch is damaged. 5. Check whether the pressure switch hose leaks gas or not. 6. Check whether the relevant wiring harness is broken. Instrument Eyeballing Eyeballing Eyeballing Eyeballing Eyeballing Blowing Check by hand Eyeballing Multimeter Eyeballing Multimeter Eyeballing Multimeter Eyeballing Eyeballing Multimeter Eyeballing Multimeter Eyeballing Eyeballing Multimeter Eyeballing Eyeballing Multimeter Eyeballing Blowing Eyeballing Multimeter Solutions If normal, go on with the next step. If normal, go on with the next step. If normal, go on with the next step. If normal, go on with the next step. If normal, go on with the next step. If normal, go on with the next step. If normal, go on with the next step. If normal, change power drive board. If normal, go on with the next step. If normal, go on with the next step. If normal, change power drive board. If normal, go on with the next step. If normal, go on with the next step. If normal, go on with the next step. If normal, go on with the next step. If normal, go on with the next step. If normal, change power drive board.
Err5 Alarm
11
Err8 Alarm
Wiring circuit
78
77
porthole outer frame porthole protection porthole glass porthole inner frame screw-hinge nut-hinge hinge sleeve hinge base board clip-base board1 screw-pump clip-base board2 front cabinet screw-control screw-trough screw-porthole porthole hook screw-hook porthole handle pin the spring of porthole porthole handle distribution handle control panelHT1206 control panelHT1006 program knob program knob accessory screw-program board program selector screw siphon cover handle lock button 1 button 2 gasket VFD board box cover VFD display boardHT1206 VFD display boardHT1006 VFD board box screw-VFD board box power board door lock handle
cable assembly pressure switch screw-perssure switch antijamming filter cylinder film alveolar washer-filter nut-filter top panel assembly screw-top panel valve screw-valve clip-valve hose hose-prewash hose-main wash trough assembly power wire film screw-power board box power board box screw-power board screw-plastic cylinder plastic cylinder cable clip(black) cable clip(white) drain pipe clip temperature sensor screw-power terminal copper bolt copper washer alveolar washer back cover screw-back cover drain pipe clip nylon nut rear cabinet foot nut foot distribution screw cable module clip(black) box
Sincere Forever
Haier Group
Tel:86-532-88939999 Web site:http://www.haier.com