THYRISTORS AND CONTROLLED AC/AC CONVERTERS DL DCA202.

Power Electronics

DL DCA202.1

blank page

II

ver a20120201

DL DCA202.1

CONTENTS

1. THEORETICAL SECTION 1.1 INTRODUCTION 1.2 TRIAC 1.3 SINGLE-PHASE AC CONTROLLER W1 (W1C) 1.3.1 Inductive load 1.3.2 Ohmic-inductive load 1.4 HALF-CONTROLLED SINGLE-PHASE CONTROLLER W1H 1.5 THREE-PHASE CONTROLLERS 1.5.1 Fully-controlled controller W3C 1.5.2 Half-controlled controller W3H 1.5.3 Controller W3C2 with two pairs of antiparallel SCRs 2. INFORMATIONS 2.1 EXPERIMENT COMPONENTS 2.2 SETTING UP AND CONDUCTING EXPERIMENTS 2.3 MEASUREMENTS WITH OSCILLOSCOPE 2.3.1 No mains isolation 2.3.2 Power supply via a transformer with isolated windings 2.3.3 Current measurement 2.3.4 Current and voltage measurement 2.3.5 Isolation amplifier 2.4 SAFETY INFORMATION Page 21 Page 22 Page 23 Page 23 Page 24 Page 25 Page 25 Page 26 Page 26 Page 1 Page 2 Page 3 Page 6 Page 8 Page 10 Page 12 Page 12 Page 15 Page 17

ver a20120201

III

DL DCA202.1 EXPERIMENTS

EXPERIMENT N1 TRIAC EXPERIMENT N2A Single-phase ac controller W1C, ohmic load EXPERIMENT N2B Single-phase ac controller W1C, inductive load EXPERIMENT N2C Single-phase ac controller W1C, ohmic-inductive load EXPERIMENT N3A Single-phase ac controller W1, ohmic load EXPERIMENT N3B Single-phase ac controller W1, ohmic-inductive load EXPERIMENT N4 Half-controlled single-phase controller W1H, ohmic load EXPERIMENT N5 Fully-controlled three-phase controller W3C, star ohmic load without neutral EXPERIMENT N6 Half-controlled three-phase controller W3H, star ohmic load without neutral EXPERIMENT N7 Three-phase controller W3C2, star ohmic load without neutral

Page 29

Page 35

Page 43

Page 51

Page 59

Page 65

Page 71

Page 77

Page 83

Page 89

IV

ver a20120201

DL DCA202.1 1. THEORETICAL SECTION

1.1 INTRODUCTION The continuous control of alternating electrical energy is normally performed by means of thyristors that are suitable for use as static switches on account of their extremely high switching capacity. The thyristor family includes unidirectional devices as the SCRs and bidirectional devices as the TRIACs. As switch conducts current in both direction so two SCRs must always be connected back-to-back (pair of antiparallel arms) while the TRIAC can be used instead of the two antiparallel SCRs.

PRIOR KNOWLEDGE 1) Knowledge of diodes and uncontrolled rectifiers (DL DCA 201.1) 2) Knowledge of SCRs and controlled rectifiers (DL DCA 201.2)

ver a20120201

DL DCA202.1 1.2 TRIAC A TRIAC can be considered as two parallel SCRs oriented in opposite directions and integrated into a semiconductor chip to provide symmetrical bidirectional characteristics, as shown in the

following Fig.1.

Fig.1 TRIAC symbol and volt-ampere characteristic TRIACs have two main terminals MT1 and MT2 and one gate terminal G. The switching behaviour is the same as that of two back-to-back SCRs and because of its complex structure a TRIAC can be triggered by either a positive or a negative gate signal regardless of the voltage polarity across the main terminals. The gate trigger modes for TRIAC are depicted in the following table, where the polarities are referenced to terminal MT1.

Quadrant

Mode

MT2

QI QI QIII QIII

I+ IIII+ III-

+ + -

+ + -

Because the direction of the principal current influences the trigger current, the trigger sensitivity is higher in the I+ and III- trigger modes.

ver a20120201

DL DCA202.1 1.3 SINGLE-PHASE AC CONTROLLER W1 (W1C) The most simple device used to continuously adjust the ac power is shown in the following Fig.2, where two antiparallel SCRs can be used instead of the TRIAC.

Fig.2 Ac controller with TRIAC (W1) and with two antiparallel SCRs (W1C) The power regulation is accomplished by varying the control angle of the TRIAC (of the two SCRs) during each half-period, as shown in the following Fig.3.

Fig.3 Phase-angle control, ohmic load

In the case of an ohmic load, the load current rises to the instantaneous value of the sinusoidal continuous current at the moment of firing angle and then flows in phase with the sinusoidal supply voltage until the zero transition is reached. The load current can be continuously varied via the control angle between the maximum value ( = 0) and zero ( = 180). During the conduction phase the supply voltage is connected to the load; during the off-phase it is present at the controller as a reverse voltage.

ver a20120201

DL DCA202.1 All the following characteristics values apply to resistive load, neglecting losses in the controller. 1) Average value of SCR current (controller W1C)

I TAV

U vM 1 (1 cos ) R 2

2) Rms value of SCR current (controller W1C)

I TRMS
3) Average value of load current

U vM R

1 sin2 ( ) 4 2

IAV = 0 (symmetrical control) 4) Average rectified value of load current

I AV 2 I TAV
5) Rms value of load current

U vM 1 (1 cos ) R

I RMS 2 I TRMS

U vM R

1 sin2 ( ) 2 2

Moreover the transfer characteristic reflects the relationship between the load current and the control angle , as illustrated in Fig.4, where IRMSo = UvM/R 2 is the rms value for the gate angle = 0.

Fig.4 Transfer characteristic of the rms values of the load current Controller W1(W1C), ohmic load

ver a20120201

DL DCA202.1 The power transfer characteristic reflects the relationship between the load active power P and the control angle , as illustrated in the following Fig.4a, where Po = U 2 v /R is the full drive power for the gate control angle = 0.

Fig.4a Power transfer characteristic Controller W1 (W1C), ohmic load

In addition the power factor PF on the supply side is


PF P P S Uv I

and results inductive even in circuits with ohmic load.

ver a20120201

DL DCA202.1 1.3.1 Inductive load The purely inductive load represents an ideal load: the choke coil has an ohmic dissipative resistance which cannot be disregarded.

Fig.5 Controller W1 (W1C) with ohmic load In the case of an inductive load the current generally lags of the angle = 90 behind the voltage and for this reason the control range of the controller is limited between ==90 and 180. The load current cannot change abruptly as in the case of ohmic load and so it is necessary to fire the thyristors by means of a pulse train in order to ensure the on-state when the line current has reached the latching current value.

Fig.6 Phase-angle control, inductive load When the control angle > 90 the load current is made up of sinusoidal peaks. During the conduction phase the supply voltage is connected to the load; during the off-phase it is present at the controller as a reverse voltage.

ver a20120201

DL DCA202.1 All the following characteristics values apply to inductive load, neglecting losses in the controller. 1) Average value of SCR current (controller W1C)
I TAV U vM ( - ) cos + sin L

2) Rms value of SCR current (controller W1C)

I TRMS

U vM L

1 1 3 ( ) (cos 2 ) sin cos 2 2

3) Average value of load current IAV = 0 (symmetrical control) 4) Average rectified value of load current IAV = 2 ITAV = 5) Rms value of load current IRMS =
2 U vM ( - ) cos + sin L

2 ITRMS =

U vM L

2 1 3 ( ) (cos 2 ) sin cos 2 2

Moreover the transfer characteristic reflects the relationship between the load current and the control angle , as illustrated in Fig.7, where IRMS90 = UvM/ 2 L is the rms value for the gate angle = 90.

Fig.7 Transfer characteristic of the rms values of the load current Controller W1(W1C), inductive load

ver a20120201

DL DCA202.1 1.3.2 Ohmic-inductive load Circuits containing resistance and inductance in series are a load type frequently found in practice.

Fig.8 Controller W1 (W1C), ohmic-inductive load The ohmic-inductive load represents a load case between ohmic and purely inductive load. Full drive is obtained when ==arc tan L/R and so the control range of the controller is limited between = and 180.

Fig.9 Phase-angle control, ohmic-inductive load The load current is no longer sinusoidal but is made up of sinusoidal continuous current and superimposed equalizing current decreasing with the time constant = L/R. During the conduction phase the supply voltage is connected to the load; during the off-phase it is present at the controller as a reverse voltage.

ver a20120201

DL DCA202.1 All the following characteristics values apply to ohmic-inductive load, neglecting losses in the controller. 1) Average value of SCR current (controller W1C)
I TAV U vM cos cos 2R

2) Rms value of SCR current (controller W1C) I TRMS U vM R 2 L


2

1 1 sin 2 sin 2 2 2 2 4 cos

3) Average value of load current IAV = 0 (symmetrical control) 4) Average rectified value of load current IAV = 2 ITAV = 5) Rms value of load current IRMS =
U vM cos cos R

2 ITRMS =

U vM R 2 L
2

1 1 sin 2 sin 2 2 2 4 cos

Moreover the transfer characteristic reflects the relationship between the load current and the control angle , as illustrated in Fig.10, where IRMS = UvM/ 2 [R 2 (L) 2 ] is the rms value for the gate angle = .

Fig.10 Transfer characteristic of the rms values of the load current Controller W1(W1C), ohmic-inductive load

ver a20120201

DL DCA202.1 1.4 HALF-CONTROLLED SINGLE-PHASE CONTROLLER W1H The half-controlled controller is often used for the temperature control and it is assembled with antiparallel connected SCR and diode, as shown in the following Fig.11.

Fig.11 Controller W1H. ohmic load Since the SCR can be driven in the phase angle through the positive half-cycle while the diode conducts through the entire negative half-cycle, the load voltage is not an alternating quantity but contains a direct component. All the following characteristics values apply to resistive load, neglecting losses in the controller. 1) Average value of the SCR current I TAV 2) Rms value of the SCR current Uv R 1 2 (1 cos )

I TRMS
3) Average value of the diode current

Uv R

1 sin2 ( ) 2 2

I FAV

2 Uv R

4) Rms value of the diode current I FRMS Uv 2R

10

ver a20120201

DL DCA202.1 5) Average value of load current I AV 6) Average rectified value of load current IAV = ITAV + IFAV 7) Rms value of load current Uv R 1 2 ( cos 1)

I RMS

Uv R

1 sin2 (2 ) 2 2

8)Transfer characteristic of the rms values of the load current.

I RMS U v I RMSo R

1 sin2 (2 ) 2 2

where IRMSo =Uv /R is the rms value for the gate control angle =0.

()

30

60

90

120

150

180

IRMS/IRMS0

0.99

0.95

0.87

0.77

0.72

0.707

ver a20120201

11

DL DCA202.1 1.5 THREE-PHASE CONTROLLERS When the supply voltage is a three-phase ac system it is possible the full-wave or half-wave control, as shown in the following Fig.12 for circuits without the neutral, as normally used in motor drive technology and as tested in the suggested experiments.

Fig.12 Fully control (W3C) and half-wave control (W3H). Star connected load, without neutral.

1.5.1 Fully-controlled controller W3C. Fig.13 illustrates the basic circuitry of a three-phase fully-controlled controller with symmetrical ohmic load, star connected and without neutral.

Fig.13 Controller W3C, ohmic load.

12

ver a20120201

DL DCA202.1 To understand the action of the controller it is necessary to note what follows: 1) When the pair of antiparallel SCRs is not fired, the phase voltage at associated load is equal to zero. 2) When all pairs of antiparallel SCRs have been fired, the phase voltage at the load is equal to the supply phase voltage (e.g. U1 = Uv10). 3) If only two pairs of antiparallel SCRs have been fired , the phase voltage at the load is equal to half the supply line voltage associated to the conducting pairs (e.g. U1 = Uv12). 4) The line voltage at the load is equal to the supply line voltage when the associated pairs of antiparallel SCRs are conducting (e.g. V1 and V4 on: U12 = Uv12 ):at all other times this voltage is equal to half the supply line voltage between the respective conducting arms (e.g. V1 and V6 on: U12 = - Uv13). 5) When the pair of antiparallel SCRs is not fired, a voltage UV is present at the pair. The voltage phasor diagram shows that this voltage is equal to 1.5 time the associated supply phase voltage, as illustrated in the following Fig.14 for the case (V1 - V2) off/(V3 - V4) and (V5 - V6) on:
U Va U v12 U v 23 15 . U v1 2

Fig.14 Voltage phasor diagram

ver a20120201

13

DL DCA202.1 The voltage time profiles are illustrated in the following Fig.15, where the current through the SCRs is sketched as a block diagram.

Fig.15 Voltage time profiles W3C. Symmetrical ohmic load. With ohmic load the voltage and current time profiles are identical: a complex procedure involves the determination of the transfer characteristic of the load current and for this reason we indicate only a graph, as shown in the following Fig.16, where IRMS0= Uv /R is the rms value for the gate angle = 0.

14

ver a20120201

DL DCA202.1

Fig.16 Transfer characteristic of the rms values of the load current. Controller W3C. The controller W3C with ohmic load can be controlled over the range = 0 to 150 (curve at cos = 1): when > 150 no current can flow since the inverse SCRs block. 1.5.2 Half-controlled controller W3H. Fig.17 illustrates the basic circuitry of a three-phase half-controlled controller with symmetrical ohmic load, star connected and without neutral.

Fig.17 Controller W3H, ohmic load. To understand the action of the controller it is necessary to note that the same considerations apply for the time profiles of the load voltages as already discussed for the full-controlled controller W3C (1.5.1), recalling that now the antiparallel pair consists of an SCR and of a diode so the time profiles for the positive and negative half-cycles of the load voltages are different while the voltage UV at the pair displays only positive values.

ver a20120201

15

DL DCA202.1 The voltage time profiles are illustrated in the following Fig.18, where the current through the SCRs and the diodes is sketched as a block circuit diagram.

Fig.18 Voltage time profiles W3H. Symmetrical ohmic load.

16

ver a20120201

DL DCA202.1 With ohmic load the voltage and current time profiles are identical: a complex procedure involves the determination of the transfer characteristic of the load current and for this reason we indicate only a graph, as shown in the following Fig.19, where IRMS0 = Uv /R is the rms value for the gate angle = 0.

Fig.19 Transfer characteristic of the rms values of the load current. Controller W3H, ohmic load. The controller W3H with ohmic load can be controlled over the range = 0 to 210. 1.5.3 Controller W3C2 with two pairs of antiparallel SCRs. With ohmic load it is possible to use only two pairs of antiparallel SCRs, one for phase, so to control also the third phase, as shown in the following Fig.20.

Fig.20 Controller W3C2, ohmic load.

To understand the action of the controller it is necessary to note that the same considerations apply for the time profiles of the load voltages as already discussed for the full-controlled controller W3C (1.5.1), recalling that now the phase L2 is permanently connected to the load.

ver a20120201

17

DL DCA202.1 The voltage time profiles are illustrated in the following Fig.21, where the load currents are sketched as a block circuit diagram.

Fig.21 Voltage time profiles W3C2. Symmetrical ohmic load.

18

ver a20120201

DL DCA202.1 With ohmic load the voltage and current time profiles are identical: a complex procedure involves the determination of the transfer characteristic of the load currents and for this reason we indicate only a graph, as shown in the following Fig.22, where IRMS0 = Uv /R is the rms value for the gate angle = 0.

Fig.22 Transfer characteristic of the rms values of the load currents. Controller W3C2, ohmic load.

On account of the pair of antiparalle SCRs missing in one line the load currents differ considerably and this also applies for the corresponding transfer characteristics.

ver a20120201

19

DL DCA202.1

blank page

20

ver a20120201

DL DCA202.1 2. INFORMATION

2.1 EXPERIMENT COMPONENTS 1 DL 2603 Diode stack 1 DL 2605 SCR stack 1 DL 2607 TRIAC 1 DL 2613 DC power supply 1 DL 2614 Voltage reference generator 1 DL 2616 Two pulse control unit 1 DL 2617 Six pulse control unit 1 DL 2626 Mains transformer 1 DL 2628 Super-fast fuses 1 DL 2635 Universal load 1 DL 2643 Socket with shunts 1 1 DL 2109T3PV Moving-iron voltmeter (125-250-500 V) 1 DL 2109T26 Power meter 2 DL 2109T33 True rms meter 1 Storage oscilloscope

Optional 1 DL 2642 Isolation amplifier

ver a20120201

21

DL DCA202.1 2.2 SETTING UP AND CONDUCTING EXPERIMENTS All the circuits of proposed experiments must be powered via the mains transformer. Always use safety connecting leads. Connect potential equalisation PE throughout. Connect the panels which have their own mains connection lead to the power mains. Set the measuring meters to the largest range. For current measurements using the oscilloscope use the plug-in shunt. Do not switch on the power mains until the circuitry has been carefully checked. When conducting experiments choose the most suitable measuring range of the meter. The mains voltage must be disconnected before intervening in the experiment set-up and making any changes or additions to circuitry.

22

ver a20120201

DL DCA202.1 2.3 MEASUREMENTS WITH OSCILLOSCOPE Working with a grounded conventional oscilloscope means taking certain special features into consideration, as illustrated in the following. 2.3.1 No mains isolation When the circuit is operated in a directly grounded mains, conventional two-channel oscilloscope can only be used with some difficulty and only the greatest caution. As the measurement grounds of the two channels are identical (i.e. internally connected), there is a danger of short-circuit via the probes, also in the case of single-channel measurements.

Example N.1 Short-circuit via probe. If you wish to investigate the line voltages or any other voltage not measured with respect to the neutral point, this can only be accomplished by measuring differential voltage (INVert channel 2).

Example N.2 Measuring line voltage U12 = U1N -U2N

ver a20120201

23

DL DCA202.1 2.3.2 Power supply via a transformer with isolated windings Using such a transformer greatly simplifies the measuring procedures as you can connect the ground as is most convenient.

Example N.3 Possible measuring line voltage. As the measuring ground of the oscilloscope has the potential of PE line, and thus ground potential, measuring with the oscilloscope will ground the secondary side of the transformer. This means that when the secondary voltages exceed the protective extra-low voltage, there exists a danger of contact with respect to ground. Also using such a transformer the risk of a short-circuit via the probes still exists.

Example N.4 Short-circuit via probe ground.

24

ver a20120201

DL DCA202.1 2.3.3 Current measurement The current I flowing through a load R is measured displaying on the oscilloscope the voltage drop across a shunt Rs.

Example N.5 Measuring current: I = URS / RS .

2.3.4 Current and voltage measurement Simultaneous load current and voltage across the load R can be displayed on the oscilloscope using the circuits depicted in the Examples N.6 and N.7.

Example N.6 : Simultaneous current and voltage measurement (Correct in terms of phase) The U voltage measurement is distorted by the voltage drop across the shunt RS: however, where R >> Rs this error may be ignored.

ver a20120201

25

DL DCA202.1

Example N.7 Simultaneous current and voltage measurement (Correct in terms of amplitude) The amplitudes of voltage U and current I are measured correctly but the current phase is 180 inverted : by pressing the INVert button on channel 2 of the oscilloscope you can display the current with the correct phase. NOTE For measurement using two-channel oscilloscope always connect only one point of the circuit to the frame of the oscilloscope. 2.3.5 Isolation amplifier Where possible, connect an isolating amplifier in series to the oscilloscope in order to ensure potential-free recording of the measured value.

2.4 SAFETY INFORMATION Laboratory work always entails a higher risk of accidents. The device may only be operated by persons who are in a position to recognise shock hazards and to implement the proper safety measures. If measurements are to be made where there is a shock hazard, IT IS NOT PERMITTED TO WORK ALONE: a second person must be informed. In accordance with the IEC regulations, metal parts not carrying a voltage in normal operation (e.g. housings) are to be connected to the PE ground conductor. The ground conductor is provided solely for this purpose and may not be connected with the neutral conductor N of the circuit!

26

ver a20120201

DL DCA202.1

EXPERIMENTS

Foreword All the measurement results were obtained at a mains frequency of 50 Hz. Of course, they cannot be reproduced exactly, due to the tolerance of the components, to the measuring devices, and, besides, to voltage fluctuations. Oscillograms are referred to a Tektronix Digital Real-Time oscilloscope TDS.

ver a20120201

27

DL DCA202.1

blank page

28

ver a20120201

DL DCA202.1 EXPERIMENT N1

TRIAC Objectives: Recording the volt-ampere characteristic of the TRIAC Recording the influence of variable control angle on the conduction of the device Determining the threshold voltage. Testing the behaviour of the TRIAC with reversal of connections. Equipments: 1 DL 2607 TRIAC 1 DL 2613 Dc power supply 1 DL 2614 Voltage reference generator 1 DL 2616 Two pulse control unit 1 DL 2626 Mains transformer 1 DL 2628 Super-fast fuses (3x6.3 A) 1 DL 2635 Universal load 1 DL 2643 Socket with shunts 1 1 DL 2109T2A5 Moving-iron ammeter (2.5 A) 1 DL 2109T3PV Moving-iron voltmeter (125-250-500 V) 1 Dual-channel oscilloscope (preferred storage type) Circuit diagram

ver a20120201

29

DL DCA202.1 EXPERIMENT N1: TRIAC

30

ver a20120201

DL DCA202.1 Experiment procedure Assemble the circuit according with the foregoing topographic diagram. 1) Connections Connect the voltage reference generator DL 2614 and the control unit DL2616 to the power supply +15V/0/-15V. Connect the output Uo of voltage generator to input Uc of the control unit. Connect the terminals L/N (USYN) of the control unit respectively to terminals 2V1/2V3 of the mains transformer. Connect in parallel with correct polarity the pulse transformers 2 and 4 and after connect the gate/terminal MT1 circuit of the TRIAC: socket marked with a dot to the gate (gate trigger mode I+/III+).

2) Basic settings 2.1) Voltage reference generator DL 2614 EXT/INT switch on INT position. (0/+10V)/(0/10V) switch on (0/+10V) position. Setpoint potentiometer to approx. 5 V. 2.2) Control unit DL 2616. Control angle o switch on 0 position. Pulse shape switch on single pulse position. Inhibit voltage UINH = 15 V (open). 3) Oscilloscope setting DC coupling; XY mode. Channel 1 (X axis): 20 V/div; probe x10. The TRIAC voltage is applied to the X-deflecting plates (UT = UCH1). Channel 2 (Y axis): 500 mV/div; probe x1. The voltage applied to the Y-deflecting plates is proportional to the TRIAC current and is tapped at shunt Rs = 1 (IT = UCH2/Rs; 0.5 A/div). Note When the oscilloscope makes it possible, invert channel 2 in order to display the characteristic in the usual manner, otherwise the current axis results downward orientated.

ver a20120201

31

DL DCA202.1 4) Complete characteristic Set the spot in the centre of the oscilloscope screen. Supply the circuit and record the complete characteristic of the TRIAC.

The oscillogram reflects the dynamic characteristic I = f(U) of the TRIAC. In the first and third quadrants the TRIAC behaves like an SCR in the first quadrant and thus operates in the same way as two SCRs connected in antiparallel (back-to-back). 5) Variable control angle. The gate controlled turn-on time (control angle ) can be varied altering the control voltage Uc on the setting point potentiometer Uo. 5.1) Control voltage Uo = Uc = 10 V ( = 0).

The TRIAC is turned on and only short sections of the blocking characteristic is recorded.

32

ver a20120201

DL DCA202.1 5.2) Control voltage Uo = Uc = 0 V ( = 180)

The TRIAC cannot be fired and the oscillogram only includes the blocking characteristic. 6) Forward characteristic In order to determine the threshold voltage set the following deflection factors channel 1: 500 mV/div; probe x10; channel 2: 200 mV/div; probe x1.

Considering the inclined piecewise linear approximation for the TRIAC characteristic it is possible to determine the threshold voltage UT(TO) 0.8 V

ver a20120201

33

DL DCA202.1 7) Reversal connections (Uc = 5 V) 7.1) Reversing gate/terminal MT1 connections There is no change in the TRIAC characteristic (gate trigger mode (I-/III-). 7.2) Reversing the polarity of synchronising voltage. There is no change in the TRIAC characteristic (gate trigger mode (I-/III-). 7.3) Reversing MT1 /MT2 connections. There is no change in the TRIAC characteristic (gate trigger mode (I+/III-).

34

ver a20120201

DL DCA202.1 EXPERIMENT N2A

SINGLE-PHASE AC CONTROLLER W1C, OHMIC LOAD Objectives: Recording voltage and current time profiles Voltage and current measurements Determination of various characteristic data Equipments: 1 DL 2605 SCR stack 1 DL 2613 Dc power supply 1 DL 2614 Voltage reference generator 1 DL 2616 Two pulse control unit 1 DL 2626 Mains transformer 1 DL 2628 Super-fast fuses (3x6.3 A) 1 DL 2635 Universal load 1 DL 2643 Socket with shunts 1 2 DL 2109T33 True rms meter 1 Dual-channel oscilloscope (preferred storage type) Circuit diagram

ver a20120201

35

DL DCA202.1 EXPERIMENT N2A: CONTROLLER W1C, OHMIC LOAD

36

ver a20120201

DL DCA202.1 Experiment procedure Assemble the circuit according with the foregoing topographic diagram, disregarding details (a) and (b) at first. 1) Connections Connect the voltage reference generator DL 2614 and the control unit DL2616 to the power supply +15V/0/-15V. Connect the output Uo of voltage generator to input Uc of the control unit. Connect the terminals L/N (USYN) of the control unit respectively to terminals 2V1/2V3 of the mains transformer. Connect the pulse transformers 1 and 3 to gate/cathode circuit of the SCRs V1 and V3 respectively: socket marked with a dot to the gate. 2) Basic settings 2.1) Voltage reference generator DL 2614 EXT/INT switch on INT position. (0/+10V)/(0/10V) switch on (0/+10V) position. Setpoint potentiometer to 10 V. 2.2) Control unit DL 2616. Control angle o switch on 0 position. Pulse shape switch on single pulse position. Inhibit voltage UINH = 15 V (open). 3) Voltage and current measurements Supply the circuit and measure: 3.1) the rms value Uv of the supply voltage by the voltmeter P1; 3.2) the average value IT3AV and the rms value IT3RMS of the SCR V3 current by the ammeter P2. 3.3) the rms value URMS of the load voltage by the voltmeter P3; 3.4) the rms value IRMS of the load current by the ammeter P4. Enter the measured value as a function of the gate angle in 30 steps between 0 and 180in the following table. HINT In order to set the gate angle, set only a half-wave of the direct voltage with the width of 9 (or 6) grid divisions on the oscilloscope: each division then corresponds to an angle of 20 (or 30).

ver a20120201

37

DL DCA202.1 Another system is the use of phase shift 0 in the control unit: 1) Set 0 = 0 and Uc = 10 V to obtain the firing angle = 0 and carry out the measurements. 2) Set now 0 = 30 to obtain the firing angle = 30 and, for example, note down the IRMS30 value. 3) Set again 0 = 0 and adjust Uc in order to obtain IRMS30 and now set again 0 = 30 in order to obtain the firing angle = 60: note down IRMS60 . 4) Set again 0 = 0and adjust Uc in order to obtain IRMS60 and now set again 0 = 30 in order to obtain the firing angle = 90 and so on. () Uv (V) UdRMS (V) IdRMS (A) IT3AV (A) IT3RMS (A) 0 46 46 1.3 0.57 0.89 30 46 45 1.28 0.52 0.87 60 46 40.5 1.12 0.41 0.79 90 46.5 22.9 0.85 0.26 0.6 120 47 16.2 0.49 0.115 0.34 150 47 4.4 0.13 0.02 0.096 180 47 0.35 0.04 0 0.01

Evaluate the various characteristic data of the controller and compare these with the theoretical values (see 1.3,page 3). () IRMS/IRMS0 0 1 30 0.9285 60 0.86 90 0.65 120 0.38 150 0.1 180 0

Draw the transfer characteristic IRMS/IRMS0 = f().

The measured transfer characteristic coincides relatively well with the theoretical curve shown in the Fig.4, page 4.

38

ver a20120201

DL DCA202.1 4) Recording on the oscilloscope Note Since the basic instrument set does not normally allow simultaneous measurements, the measures may have to be carried out successively. 4.1) Recording the load U voltage and I current. Oscilloscope setting DC coupling; Yt mode. Trigger: AC Line. Channel 1 (voltage U): 50 V/div; probe x10. Channel 2 (current I proportional to voltage at shunt RS2 =1 ): 1 V/div; probe x1. Oscillogram ( = 90)

The load current is alternately made up of the two SCR currents.

ver a20120201

39

DL DCA202.1 4.2) Recording the SCR V3 voltage UV3 and current IT3. Oscilloscope setting. Assemble the measuring circuit according with detail (a). Channel 1 (UV3 voltage): 50 V/div ; probe x10. Channel 2 (current IT3 proportional to voltage at shunt RS3 = 1 ): 1 V/div; probe x1. Oscillogram ( = 90)

The SCR V3 controls the positive half-wave. During the SCR blocking phase the voltage in the two antiparallel SCRs is identical to the supply voltage.

40

ver a20120201

DL DCA202.1 4.3) Recording the SCR V1 voltage UV1 and current IT1. Oscilloscope setting. Assemble the measuring circuit according with detail (b). Channel 1 (UV1 voltage): 50 V/div; probe x10. Channel 2 (current IT1 proportional to voltage at shunt RS1 = 1 ): 1 V/div; probe x1. Oscillogram ( = 90)

The SCR V1 controls the negative half-wave. During the SCR blocking phase the voltage in the two antiparallel SCRs is identical to the supply voltage.

ver a20120201

41

DL DCA202.1

blank page

42

ver a20120201

DL DCA202.1 EXPERIMENT N2B

SINGLE-PHASE AC CONTROLLER W1C, INDUCTIVE LOAD Objectives: Recording voltage and current time profiles Voltage and current measurements Determination of various characteristic data Equipments: 1 DL 2605 SCR stack 1 DL 2613 Dc power supply 1 DL 2614 Voltage reference generator 1 DL 2616 Two pulse control unit 1 DL 2626 Mains transformer 1 DL 2628 Super-fast fuses (3x6.3 A) 1 DL 2635 Universal load 1 DL 2643 Socket with shunts 1 2 DL 2109T33 True rms meter 1 Dual-channel oscilloscope (preferred storage type) Circuit diagram

ver a20120201

43

DL DCA202.1 EXPERIMENT N2B: CONTROLLER W1C, INDUCTIVE LOAD

44

ver a20120201

DL DCA202.1 Experiment procedure Assemble the circuit according with the foregoing topographic diagram, disregarding details (a) and (b) at first. 1) Connections Connect the voltage reference generator DL 2614 and the control unit DL2616 to the power supply +15V/0/-15V. Connect the output Uo of voltage generator to input Uc of the control unit. Connect the terminals L/N (USYN) of the control unit respectively to terminals 2V1/2V3 of the mains transformer. Connect the pulse transformers 1 and 3 to gate/cathode circuit of the SCRs V1 and V3 respectively: socket marked with a dot to the gate. 2) Basic settings 2.1) Voltage reference generator DL 2614 EXT/INT switch on INT position. (0/+10V)/(0/10V) switch on (0/+10V) position. Setpoint potentiometer to 0 V. 2.2) Control unit DL 2616. Control angle o switch on 0 position. Pulse shape switch on train pulse position. Inhibit voltage UINH = 15 V (open). 3) Voltage and current measurements Supply the circuit and measure: 3.1) the rms value Uv of the supply voltage by the voltmeter P1; 3.2) the average value IT3AV and the rms value IT3RMS of the SCR V3 current by the ammeter P2. 3.3) the rms value URMS of the load voltage by the voltmeter P3; 3.4) the rms value IRMS of the load current by the ammeter P4. Enter the measured value as a function of the gate angle in 30 steps between 0 and 180in the following table. CONTROL RANGE In the case of inductive load the current generally lags 90 behind the voltage and for this reason the controller can only be controlled between 90 and 180. Increase the control voltage Uc until the oscilloscope shows the load voltage U and current I in a sinusoidal continuous form; at this point slowly decrease the control voltage Uc until the oscilloscope shows the full drive of both SCRs at the gate angle corresponding to the load phase angle that, on account of the dissipative choke, results less than 90.

ver a20120201

45

DL DCA202.1

Approximately the load phase angle results = 85. HINT In order to set the gate angle, set only a half-wave of the direct voltage with the width of 9 (or 6) grid divisions on the oscilloscope: each division then corresponds to an angle of 20 (or 30). Another system is the use of phase shift 0 in the control unit: 1) Set 0 = 0 and adjust Uc in order to obtain the firing angle = 90 pointed out on the oscilloscope and carry out the measurements. 2) Set now 0 = 30 in order to obtain the firing angle = 120 and, for example, note down the IRMS120 value. 3) Set again 0 = 0 and adjust Uc in order to obtain IRMS120 and now set again 0 = 30 in order to obtain the firing angle = 150 and so on..

46

ver a20120201

DL DCA202.1 () Uv (V) UdRMS (V) IdRMS (A) IT3AV (A) IT3RMS (A) 47 48 2.84 1.25 0.89

90 47 47 2.72 1.18 0.6

120 48 32 1.35 0.53 0.34

150 48 14 0.35 0.15 0.096

180 48 4.3 0 0 0

Evaluate the various characteristic data of the controller and compare these with the theoretical values (see 1.3.1,page 6). () IRMS/IRMS0 1 90 0.957 120 0.475 150 0.123 180 0

Draw the transfer characteristic IRMS/IRMS = f().

The measured transfer characteristic coincides relatively well with the theoretical curve shown in the Fig.7, page 7.

ver a20120201

47

DL DCA202.1 4) Recording on the oscilloscope Note Since the basic instrument set does not normally allow simultaneous measurements , the measures may have to be carried out successively. 4.1) Recording the load U voltage and I current. Oscilloscope setting DC coupling; Yt mode. Trigger: AC Line. Channel 1 (voltage U): 50 V/div; probe x10. Channel 2 (current I proportional to voltage at shunt RS2 = 1 ): 2 V/div; probe x1. Oscillogram ( = 120)

The load current is basically made up of the two SCR currents with sinusoidal peaks.

48

ver a20120201

DL DCA202.1 4.2) Recording the SCR V3 voltage UV3 and current IT3. Oscilloscope setting. Assemble the measuring circuit according with detail (a). Channel 1 (UV3 voltage): 50 V/div ; probe x10. Channel 2 (current IT3 proportional to voltage at shunt RS3 = 1 ): 2 V/div ; probe x1. Oscillogram ( = 120)

The SCR V3 controls the positive half-wave. During the SCR blocking phase the voltage in the two antiparallel SCRs is identical to the supply voltage.

ver a20120201

49

DL DCA202.1 4.3) Recording the SCR V1 voltage UV1 and current IT1. Oscilloscope setting. Assemble the measuring circuit according with detail (b). Channel 1 (UV1 voltage): 50 V/div ; probe x10. Channel 2 (current IT1 proportional to voltage at shunt RS1 = 1 ): 2 V/div; probe x1. Oscillogram ( = 120)

The SCR V1 controls the negative half-wave. During the SCR blocking phase the voltage in the two antiparallel SCRs is identical to the supply voltage.

50

ver a20120201

DL DCA202.1 EXPERIMENT N2C

SINGLE-PHASE AC CONTROLLER W1C, OHMIC-INDUCTIVE LOAD Objectives: Recording voltage and current time profiles Voltage and current measurements Determination of various characteristic data Equipments: 1 DL 2605 SCR stack 1 DL 2613 Dc power supply 1 DL 2614 Voltage reference generator 1 DL 2616 Two pulse control unit 1 DL 2626 Mains transformer 1 DL 2628 Super-fast fuses (3x6.3 A) 1 DL 2635 Universal load 1 DL 2643 Socket with shunts 1 2 DL 2109T33 True rms meter 1 Dual-channel oscilloscope (preferred storage type) Circuit diagram

ver a20120201

51

DL DCA202.1 EXPERIMENT N2C: CONTROLLER W1C, OHMIC-INDUCTIVE LOAD

52

ver a20120201

DL DCA202.1 Experiment procedure Assemble the circuit according with the foregoing topographic diagram, disregarding details (a) and (b) at first. 1) Connections Connect the voltage reference generator DL 2614 and the control unit DL2616 to the power supply +15V/0/-15V. Connect the output Uo of voltage generator to input Uc of the control unit. Connect the terminals L/N (USYN) of the control unit respectively to terminals 2V1/2V3 of the mains transformer. Connect the pulse transformers 1 and 3 to gate/cathode circuit of the SCRs V1 and V3 respectively: socket marked with a dot to the gate. 2) Basic settings 2.1) Voltage reference generator DL 2614 EXT/INT switch on INT position. (0/+10V)/(0/10V) switch on (0/+10V) position. Setpoint potentiometer to 0 V. 2.2) Control unit DL 2616. Control angle o switch on 0 position. Pulse shape switch on train pulse position. Inhibit voltage UINH = 15 V (open). 3) Voltage and current measurements Supply the circuit and measure: 3.1) the rms value Uv of the supply voltage by the voltmeter P1; 3.2) the average value IT3AV and the rms value IT3RMS of the SCR V3 current by the ammeter P2. 3.3) the rms value URMS of the load voltage by the voltmeter P3; 3.4) the rms value IRMS of the load current by the ammeter P4. Enter the measured value as a function of the gate angle in 30 steps between 0 and 180in the following table.

CONTROL RANGE In the case of ohmic-inductive load the current lags behind the voltage of an angle =arctgL/R and for this reason the controller can only be controlled between and 180. Increase the control voltage Uc until the oscilloscope shows the load voltage U and current I in a sinusoidal continuous form; at this point slowly decrease the control voltage Uc until the oscilloscope shows the full drive of both SCRs at the gate angle corresponding to the load phase angle .

ver a20120201

53

DL DCA202.1

Approximately the load phase angle results = 25. HINT In order to set the gate angle, set only a half-wave of the direct voltage with the width of 9 (or 6) grid divisions on the oscilloscope: each division then corresponds to an angle of 20 (or 30). Another system is the use of phase shift 0 in the control unit: 1) Set 0 = 0 and Uc = 10 V to obtain the firing angle = 0 and carry out the measurements. 2) Set now 0 = 30 to obtain the firing angle = 30 and, for example, note down the IRMS30 value. 3) Set again 0 = 0 and adjust Uc in order to obtain IRMS30 and now set again 0 = 30 in order to obtain the firing angle = 60: note down IRMS60. 4) Set again 0 = 0and adjust Uc in order to obtain IRMS60 and now set again 0 = 30 in order to obtain the firing angle = 90 and so on.

54

ver a20120201

DL DCA202.1 () Uv (V) UdRMS (V) IdRMS (A) IT3AV (A) IT3RMS (A) 47 47 1.15 0.52 0.81

30 46.5 46.5 1.12 0.5 0.79

60 47 41 0.95 0.38 0.67

90 48 31 0.67 0.23 0.47

120 48 17.2 0.31 0.09 0.23

150 48 4.8 0.05 0.011 0.044

180 48 0 0 0 0

Evaluate the various characteristic data of the controller and compare these with the theoretical values (see 1.3.2,page 8). () IRMS/IRMS0 0 1 30 0.97 60 0.83 90 0.58 120 0.27 150 0.044 180 0

Draw the transfer characteristic IRMS/IRMS = f().

The measured transfer characteristic coincides relatively well with the theoretical curve shown in the Fig.10, page 9.

ver a20120201

55

DL DCA202.1 4) Recording on the oscilloscope Note Since the basic instrument set does not normally allow simultaneous measurements, the measures may have to be carried out successively. 4.1) Recording the load U voltage and I current. Oscilloscope setting DC coupling; Yt mode. Trigger: AC Line. Channel 1 (voltage U): 50 V/div; probe x10. Channel 2 (current I proportional to voltage at shunt RS2 = 1 ): 2 V/div; probe x1. Oscillogram ( = 90)

The load current is basically made up of the two SCR currents with sinusoidal peaks and smoothing effect.

56

ver a20120201

DL DCA202.1 4.2) Recording the SCR V3 voltage UV3 and current IT3 . Oscilloscope setting. Assemble the measuring circuit according with detail (a). Channel 1 (UV3 voltage): 50 V/div; probe x10. Channel 2 (current IT3 proportional to voltage at shunt RS3 = 1 ): 2 V/div; probe x1. Oscillogram ( = 90)

The SCR V3 controls the positive half-wave. During the SCR blocking phase the voltage in the two antiparallel SCRs is identical to the supply voltage.

ver a20120201

57

DL DCA202.1 4.3) Recording the SCR V1 voltage UV1 and current IT1 . Oscilloscope setting. Assemble the measuring circuit according with detail (b). Channel 1 (UV1 voltage): 50 V/div; probe x10. Channel 2 (current IT1 proportional to voltage at shunt RS1 = 1 ): 2 V/div; probe x1. Oscillogram ( = 90)

The SCR V1 controls the negative half-wave. During the SCR blocking phase the voltage in the two antiparallel SCRs is identical to the supply voltage.

58

ver a20120201

DL DCA202.1 EXPERIMENT N3A

SINGLE-PHASE AC CONTROLLER W1, OHMIC LOAD Objectives: Recording voltage and current time profiles Voltage and current measurements Determination of various characteristic data Equipments: 1 DL 2607 TRIAC 1 DL 2613 Dc power supply 1 DL 2614 Voltage reference generator 1 DL 2616 Two pulse control unit 1 DL 2626 Mains transformer 1 DL 2628 Super-fast fuses (3x6.3 A) 1 DL 2635 Universal load 1 DL 2643 Socket with shunts 1 1 DL 2109T3PV Moving iron voltmeter (125-250-500 V) 1 DL 2109T26 Power meter 1 DL 2109T33 True rms meter 1 Dual-channel oscilloscope (preferred storage type) Circuit diagram

ver a20120201

59

DL DCA202.1 EXPERIMENT N3A: CONTROLLER W1, OHMIC LOAD

60

ver a20120201

DL DCA202.1

Experiment procedure Assemble the circuit according with the foregoing topographic diagram, disregarding detail (a) at first. 1) Connections Connect the voltage reference generator DL 2614 and the control unit DL2616 to the power supply +15V/0/-15V. Connect the output Uo of voltage generator to input Uc of the control unit. Connect the terminals L/N (USYN) of the control unit respectively to terminals 2V1/2V3 of the mains transformer. Connect in parallel with correct polarity the pulse transformers 2 and 4 and after connect the gate/terminal MT1 circuit of the TRIAC: socket marked with a dot to the gate. 2) Basic settings 2.1) Voltage reference generator DL 2614 EXT/INT switch on INT position. (0/+10V)/(0/10V) switch on (0/+10V) position. Setpoint potentiometer to 10 V. 2.2) Control unit DL 2616. Control angle o switch on 0 position. Pulse shape switch on single pulse position. Inhibit voltage UINH = 15 V (open). 3) Voltage and current measurements Supply the circuit and measure: 3.1) the rms value Uv of the supply voltage by the voltmeter P1; 3.2) the active power P on the mains side by the wattmeter P2. 3.3) the rms value URMS of the load voltage by the voltmeter P3; 3.4) the rms value IRMS of the load current by the ammeter P4. Enter the measured value as a function of the gate angle in 30 steps between 0 and 180in the following table. HINT In order to set the gate angle, set only a half-wave of the direct voltage with the width of 9 (or 6) grid divisions on the oscilloscope: each division then corresponds to an angle of 20 (or 30).

ver a20120201

61

DL DCA202.1 Another system is the use of phase shift 0 in the control unit: 1) Set 0 = 0 and Uc = 10 V to obtain the firing angle = 0 and carry out the measurements. 2) Set now 0 = 30 to obtain the firing angle = 30 and, for example, note down the IRMS30 value. 3) Set again 0 = 0 and adjust Uc in order to obtain IRMS30 and now set again 0 = 30 in order to obtain the firing angle = 60: note down IRMS60 . 4) Set again 0 = 0and adjust Uc in order to obtain IRMS60 and now set again 0 = 30 in order to obtain the firing angle = 90 and so on. Uv = 45 V () UdRMS (V) IdRMS (A) P (W)

0 45 1.28 59

30 44.5 1.25 55

60 40 1.1 43

90 29 0.86 25

120 16.1 0.5 7

150 4.7 0.15 --

180 0 0 0

Evaluate the various characteristic data of the controller and compare these with the theoretical values (see 1.3,page 3). () IRMS/IRMS0 P/P0 S (VA) PF 0 1 1 58 1 30 0.98 0.93 56.3 0.97 60 0.86 0.73 49.5 0.87 90 0.67 0.42 38.7 0.65 120 0.39 0.12 22.5 0.31 150 0.12 ---180 0 0 0 0

Draw the transfer characteristics of the rms values of the load current and of the active power.

The measured transfer characteristics coincide relatively well with the theoretical curves shown in the Fig.4(page 4) and Fig.4a (page 5).

62

ver a20120201

DL DCA202.1 A comparison of the active power P and apparent power S shows that P S when the control angle = 0 ( the current is effectively sinusoidal and in phase with the voltage) while as the control angle increases the active power decreases more sharply than the apparent power. The phase-angle control produces an inductive reactive power even in circuits with ohmic load due to the phase shift between the fundamental component and the harmonic content of the current. 4) Recording on the oscilloscope Note Since the basic instrument set does not normally allow simultaneous measurements , the measures may have to be carried out successively. 4.1) Recording the supply Uv and the load U voltages. Oscilloscope setting DC coupling; Yt mode. Trigger: AC Line. Channel 1 (voltage Uv): 50 V/div; probe x100. Channel 2 (voltage U): 50 V/div; probe x100. Oscillogram ( = 90)

The load voltage is an alternating quantity,with positive and negative phase control.

ver a20120201

63

DL DCA202.1 4.2) Recording the TRIAC V voltage UV and load current I. Oscilloscope setting. Assemble the measuring circuit according with detail (a). Channel 1 (UV voltage): 50 V/div; probe x100. Channel 2 (current I proportional to voltage at shunt RS = 1 ): 2 V/div; probe x1. Oscillogram ( = 90)

During the TRIAC blocking phase the voltage in the TRIAC is identical to the supply voltage. The load current is an alternating quantity, with positive and negative phase control.

64

ver a20120201

DL DCA202.1 EXPERIMENT N3B

SINGLE-PHASE AC CONTROLLER W1, OHMIC-INDUCTIVE LOAD Objectives: Recording voltage and current time profiles Voltage and current measurements Determination of various characteristic data Equipments: 1 DL 2607 TRIAC 1 DL 2613 Dc power supply 1 DL 2614 Voltage reference generator 1 DL 2616 Two pulse control unit 1 DL 2626 Mains transformer 1 DL 2628 Super-fast fuses (3x6.3 A) 1 DL 2635 Universal load 1 DL 2643 Socket with shunts 1 1 DL 2109T3PV Moving iron voltmeter (125-250-500 V) 1 DL 2109T26 Power meter 1 DL 2109T33 True rms meter 1 Dual-channel oscilloscope (preferred storage type) Circuit diagram

ver a20120201

65

DL DCA202.1 EXPERIMENT N3B: CONTROLLER W1, OHMIC-INDUCTIVE LOAD

66

ver a20120201

DL DCA202.1 Experiment procedure Assemble the circuit according with the foregoing topographic diagram, disregarding detail (a) at first. 1) Connections Connect the voltage reference generator DL 2614 and the control unit DL2616 to the power supply +15V/0/-15V. Connect the output Uo of voltage generator to input Uc of the control unit. Connect the terminals L/N (USYN) of the control unit respectively to terminals 2V1/2V3 of the mains transformer. Connect in parallel with correct polarity the pulse transformers 2 and 4 and after connect the gate/terminal MT1 circuit of the TRIAC: socket marked with a dot to the gate. 2) Basic settings 2.1) Voltage reference generator DL 2614 EXT/INT switch on INT position. (0/+10V)/(0/10V) switch on (0/+10V) position. Setpoint potentiometer to 10 V. 2.2) Control unit DL 2616. Control angle o switch on 30 position. Pulse shape switch on train pulse position. Inhibit voltage UINH = 15 V (open). 3) Voltage and current measurements Supply the circuit and measure: 3.1) the rms value Uv of the supply voltage by the voltmeter P1; 3.2) the active power P on the mains side by the wattmeter P2. 3.3) the rms value URMS of the load voltage by the voltmeter P3; 3.4) the rms value IRMS of the load current by the ammeter P4. Enter the measured value as a function of the gate angle in 30 steps between 30 and 180in the following table. HINT In order to set the gate angle, set only a half-wave of the direct voltage with the width of 9 (or 6) grid divisions on the oscilloscope: each division then corresponds to an angle of 20 (or 30).

ver a20120201

67

DL DCA202.1 Another system is the use of phase shift 0 in the control unit: 1) Set 0 = 30 and Uc = 10 V to obtain the firing angle = 30and, for example, note down the IRMS30 value. 2) Set again 0 = 0 and adjust Uc in order to obtain IRMS30 and now set again 0 = 30 in order to obtain the firing angle = 60: note down IRMS60. 3) Set again 0 = 0and adjust Uc in order to obtain IRMS60 and now set again 0 = 30 in order to obtain the firing angle = 90 and so on. Uv = 45 V () UdRMS (V) IdRMS (A) P (W)

30 40 1.1 45

60 34 0.95 31

90 22.3 0.67 15

120 11 0.33 3.2

150 1.8 0.06 --

180 0 0 0

Evaluate the various characteristic data of the controller. () IRMS/IRMS0 P/P0 S (VA) PF 30 1 1 49.5 0.9 60 0.86 0.69 42.8 0.73 90 0.6 0.33 30.1 0.5 120 0.3 0.07 14.9 0.2 150 0.05 -2.7 -180 0 0 0 0

Draw the transfer characteristics of the rms values of the load current and of the active power. The transfer characteristics have the same profile as determined in Experiment N.3A.

The power factor is lower than in the case of ohmic load on account of the inductive load component. The controller can be controlled only in the range between ==arctg R/L 30 and 180.

68

ver a20120201

DL DCA202.1 4) Recording on the oscilloscope Note Since the basic instrument set does not normally allow simultaneous measurements, the measures may have to be carried out successively. 4.1) Recording the supply Uv and the load U voltages. Oscilloscope setting DC coupling; Yt mode. Trigger: AC Line. Channel 1 (voltage Uv): 50 V/div; probe x100. Channel 2 (voltage U): 50 V/div; probe x100. Oscillogram ( = 90)

The feed voltage drops at the load impedance when the TRIAC is switched on.

ver a20120201

69

DL DCA202.1 4.2) Recording the TRIAC V voltage UV and load current I. Oscilloscope setting. Assemble the measuring circuit according with detail (a). Channel 1 (UV voltage): 50 V/div; probe x100. Channel 2 (current I proportional to voltage at shunt RS = 1 ): 2 V/div; probe x1. Oscillogram ( = 90)

During the TRIAC blocking phase the voltage in the TRIAC is identical to the supply voltage. The load current is basically made up of smoothed sinusoidal peaks.

70

ver a20120201

DL DCA202.1 EXPERIMENT N4

HALF-CONTROLLED SINGLE-PHASE CONTROLLER W1H, OHMIC LOAD Objectives: Recording voltage and current time profiles Voltage and current measurements Determination of various characteristic data Equipments: 1 DL 2603 Diode stack 1 DL 2605 SCR stack 1 DL 2613 Dc power supply 1 DL 2614 Voltage reference generator 1 DL 2616 Two pulse control unit 1 DL 2626 Mains transformer 1 DL 2628 Super-fast fuses (3x6.3 A) 1 DL 2635 Universal load 1 DL 2643 Socket with shunts 1 2 DL 2109T33 True rms meter 1 Dual-channel oscilloscope (preferred storage type) Circuit diagram

ver a20120201

71

DL DCA202.1 EXPERIMENT N4: CONTROLLER W1H, OHMIC LOAD

72

ver a20120201

DL DCA202.1 Experiment procedure Assemble the circuit according with the foregoing topographic diagram, disregarding details (a) and (b) at first. 1) Connections Connect the voltage reference generator DL 2614 and the control unit DL2616 to the power supply +15V/0/-15V. Connect the output Uo of voltage generator to input Uc of the control unit. Connect the terminals L/N (USYN) of the control unit respectively to terminals 2V1/2V3 of the mains transformer. Connect the pulse transformer 3 to gate/cathode circuit of the SCR V3: socket marked with a dot to the gate. 2) Basic settings 2.1) Voltage reference generator DL 2614 EXT/INT switch on INT position. (0/+10V)/(0/10V) switch on (0/+10V) position. Setpoint potentiometer to 10 V. 2.2) Control unit DL 2616. Control angle o switch on 0 position. Pulse shape switch on single pulse position. Inhibit voltage UINH = 15 V (open). 3) Voltage and current measurements Supply the circuit and measure: 3.1) the rms value Uv of the supply voltage by the voltmeter P1; 3.2) the average value IT3AV and the rms value IT3RMS of the SCR V3 current by the ammeter P2. 3.3) the average value UAV and the rms value URMS of the load voltage by the voltmeter P3; 3.4) the average value IAV and the rms value IRMS of the load current by the ammeter P4. Enter the measured value as a function of the gate angle in 30 steps between 0 and 180in the following table. HINT In order to set the gate angle, set only a half-wave of the direct voltage with the width of 9 (or 6) grid divisions on the oscilloscope: each division then corresponds to an angle of 20 (or 30).

ver a20120201

73

DL DCA202.1 Another system is the use of phase shift 0 in the control unit: 1) Set 0 = 0 and Uc = 10 V to obtain the firing angle = 0 and carry out the measurements. 2) Set now 0 = 30 to obtain the firing angle = 30 and, for example, note down the IRMS30 value. 3) Set again 0 = 0 and adjust Uc in order to obtain IRMS30 and now set again 0 = 30 in order to obtain the firing angle = 60: note down IRMS60. 4) Set again 0 = 0and adjust Uc in order to obtain IRMS60 and now set again 0 = 30 in order to obtain the firing angle = 90 and so on. () Uv (V) UAV (V) URMS (V) IAV (A) IRMS (A) IT3AV (A) IT3RMS (A) 0 45 0 45 0 1.3 0.57 0.88 30 46 1.9 45 0.052 1.28 0.52 0.86 60 46 7.7 41 0.23 1.12 0.35 0.72 90 46 11.8 38 0.35 0.85 0.24 0.58 120 46 17 34 0.48 0.49 0.11 0.33 150 47 20 33 0.58 0.13 0.02 0.1 180 47 20.5 32 0.6 0.04 0 0

Evaluate the various characteristic data of the controller and compare these with the theoretical values (see 1.4,page 10). () IRMS/IRMS0 0 1 30 0.99 60 0.94 90 0.86 120 0.76 150 0.74 180 0.73

Draw the transfer characteristic IRMS/IRMS0 = f().

The measured transfer characteristic coincides relatively well with the theoretical values.

74

ver a20120201

DL DCA202.1 4) Recording on the oscilloscope Note Since the basic instrument set does not normally allow simultaneous measurements, the measures may have to be carried out successively. 4.1) Recording the load U voltage and I current. Oscilloscope setting DC coupling; Yt mode. Trigger: AC Line. Channel 1 (voltage U ): 50 V/div; probe x10. Channel 2 (current I proportional to voltage at shunt RS2 = 1 ): 2 V/div; probe x1. Oscillogram ( = 60)

The load voltage and current are not alternating quantities but each contains a direct component.

ver a20120201

75

DL DCA202.1 4.2) Recording the SCR V3 voltage UV3 and current IT3. Oscilloscope setting. Assemble the measuring circuit according with detail (a). Channel 1 (UV3 voltage): 50 V/div; probe x10. Channel 2 (current IT3 proportional to voltage at shunt RS3 = 1 ): 2 V/div; probe x1. Oscillogram ( = 60)

The SCR V3 controls the positive half-wave. 4.3) Recording the diode V1 voltage UV1 and current IF1. Oscilloscope setting. Assemble the measuring circuit according with detail (b). Channel 1 (UV1 voltage): 50 V/div; probe x10. Channel 2 (current IT1 proportional to voltage at shunt RS1 = 1 ): 2 V/div; probe x1. Oscillogram ( = 60)

The diode conducts throughout the entire negative half-cycle.

76

ver a20120201

DL DCA202.1 EXPERIMENT N5 FULLY-CONTROLLED THREE-PHASE CONTROLLER W3C, STAR OHMIC LOAD WITHOUT NEUTRAL Objectives: Recording voltage and current time profiles Voltage and current measurements Determination of various characteristic data Equipments: 1 DL 2605 SCR stack 1 DL 2613 Dc power supply 1 DL 2614 Voltage reference generator 1 DL 2617 Six pulse control unit 1 DL 2626 Mains transformer 1 DL 2628 Super-fast fuses (3x6.3 A) 1 DL 2635 Universal load 1 DL 2109T3PV Moving-iron voltmeter (125-250-500 V) 2 DL 2109T33 True rms meter 1 Dual-channel oscilloscope (preferred storage type) Circuit diagram

ver a20120201

77

DL DCA202.1 EXPERIMENT N5: CONTROLLER W3C, OHMIC LOAD

78

ver a20120201

DL DCA202.1

Experiment procedure Assemble the circuit according with the foregoing topographic diagram, disregarding detail (a) at first. 1) Connections Connect the voltage reference generator DL 2614 and the control unit DL 2617 to the power supply +15V/0/-15V. Connect the output Uo of voltage generator to input Uc of the control unit. Connect the terminals L1/L2/L3/N (USYN) of the control unit respectively to terminals 2U1/2V1/2W1/2U3 of the mains transformer. Connect the pulse transformers 1,2,3,4,5 and 6 to gate/cathode circuit of the SCRs V1, V2 V3, V4 ,V5 and V6: socket marked with a dot to the gate. 2) Basic settings 2.1) Voltage reference generator DL 2614 EXT/INT switch on INT position. (0/+10V)/(0/10V) switch on (0/+10V) position. Setpoint potentiometer to 10 V. 2.2) Control unit DL 2617. Analog control switch on position. Control angle o switch on 0 position. Pulse shape switch on single pulse position. Select MAIN+SEC PULSE. Inhibit voltage UINH = 15 V (open). 3) Voltage and current measurements Supply the circuit and measure: 3.1) the rms value Uv10 of the supply voltage by the voltmeter P1; 3.2) the rms value I1RMS of the line current by the ammeter P2; 3.3) the rms value U12RMS of the load line voltage by the voltmeter P3; 3.4) the rms value U3RMS of the load phase voltage by the voltmeter P4. Enter the measured value as a function of the gate angle in 30 steps between 0 and 150in the following table.

ver a20120201

79

DL DCA202.1 HINT In order to set the gate angle it is possible the use of phase shift 0 in the control unit: 1) Set 0 = 0 and Uc = 10 V to obtain the firing angle = 0 and carry out the measurements. 2) Set 0 = 30 to obtain the firing angle = 30. 3) Set now 0 = 60 to obtain the firing angle = 60 and, for example, note down the I1RMS60 value. 4) Set again 0 =0 and adjust Uc in order to obtain I1RMS60 and now set again 0 =30 in order to obtain the firing angle = 90. 5) Set now 0 =60 to obtain the firing angle = 120 and, for example, note down the I1RMS120 value. 6) Set again 0 = 0and adjust Uc in order to obtain I1RMS120 and now set again 0 = 30 in order to obtain the firing angle = 150 and so on. Uv10 = 46 V () U3RMS (V) U12RMS (V) I1RMS (A)

0 46 81 0.47

30 45 79 0.46

60 37 64 0.38

90 23 41 0.24

120 7.4 12 0.022

150 0 0 0

Evaluate the various characteristic data of the converter and compare these with the theoretical values (see 1.5.1,page 12). () IRMS/IRMS0 0 1 30 0.978 60 0.8 90 0.53 120 0.21 150 0

Draw the transfer characteristic I1RMS/I1RMS0 = f().

The measured transfer characteristic coincides relatively well with the theoretical curve.

80

ver a20120201

DL DCA202.1 4) Recording on the oscilloscope Note Since the basic instrument set does not normally allow simultaneous measurements, the measures may have to be carried out successively. 4.1) Recording the load phase voltages U1 and U2. Oscilloscope setting. DC coupling; Yt mode. Trigger: AC Line. Channel 1(U1 voltage): 50 V/div, probe x10. Channel 2(U2 voltage): 50 V/div, probe x10. Oscillogram ( = 30)

Oscillogram ( = 60)

ver a20120201

81

DL DCA202.1 4.2) Recording the load line voltage U12 and the voltage UV3 at SCR V3 Oscilloscope setting. Assemble the measuring circuit according with detail (a). Channel 1 (U12 voltage): 50 V/div ; probe x10. Channel 2 (UV3 voltage): 50 V/div ; probe x10. Oscillogram ( = 30)

Oscillogram ( = 60)

82

ver a20120201

DL DCA202.1 EXPERIMENT N6

HALF-CONTROLLED THREE-PHASE CONTROLLER W3H, STAR OHMIC LOAD WITHOUT NEUTRAL Objectives: Recording voltage and current time profiles Voltage and current measurements Determination of various characteristic data Equipments: 1 DL 2603 Diode stack 1 DL 2605 SCR stack 1 DL 2613 Dc power supply 1 DL 2614 Voltage reference generator 1 DL 2617 Six pulse control unit 1 DL 2626 Mains transformer 1 DL 2628 Super-fast fuses (3x6.3 A) 1 DL 2635 Universal load 1 DL 2109T2A5 Moving iron ammeter (2.5 A) 1 DL 2109T3PV Moving-iron voltmeter (125-250-500 V) 2 DL 2109T33 True rms meter 1 Dual-channel oscilloscope (preferred storage type) Circuit diagram

ver a20120201

83

DL DCA202.1 EXPERIMENT N6: CONTROLLER W3H, OHMIC LOAD

84

ver a20120201

DL DCA202.1 Experiment procedure Assemble the circuit according with the foregoing topographic diagram, disregarding detail (a) at first. 1) Connections Connect the voltage reference generator DL 2614 and the control unit DL 2617 to the power supply +15V/0/-15V. Connect the output Uo of voltage generator to input Uc of the control unit. Connect the terminals L1/L2/L3/N (USYN) of the control unit respectively to terminals 2U1/2V1/2W1/2U3 of the mains transformer. Connect the pulse transformers 1,3 and 5 to gate/cathode circuit of the SCRs V1, V3, and V5: socket marked with a dot to the gate. 2) Basic settings 2.1) Voltage reference generator DL 2614 EXT/INT switch on INT position. (0/+10V)/(0/10V) switch on (0/+10V) position. Setpoint potentiometer to 10 V. 2.2) Control unit DL 2617. Analog control switch on position. Control angle o switch on 0 position. Pulse shape switch on single pulse position. Select MAIN PULSE. Inhibit voltage UINH = 15 V (open). 3) Voltage and current measurements Supply the circuit and measure: 3.1) the rms value Uv10 of the supply voltage by the voltmeter P1; 3.2) the rms value I1RMS of the line current by the ammeter P2; 3.3) the rms value U12RMS of the load line voltage by the voltmeter P3; 3.4) the rms value U3RMS of the load phase voltage by the voltmeter P4. Enter the measured value as a function of the gate angle in 30 steps between 0 and 180in the following table.

ver a20120201

85

DL DCA202.1 HINT In order to set the gate angle it is possible the use of phase shift 0 in the control unit: 1) Set 0 = 0 and Uc = 10 V to obtain the firing angle = 0 and carry out the measurements. 2) Set 0 = 30 to obtain the firing angle = 30. 3) Set now 0 = 60 to obtain the firing angle = 60 and, for example, note down the I1RMS60 value. 4) Set again 0 = 0 and adjust Uc in order to obtain I1RMS60 and now set again 0 = 30 in order to obtain the firing angle = 90. 5) Set now 0 = 60 to obtain the firing angle = 120 and, for example, note down the I1RMS120 value. 6) Set again 0 = 0and adjust Uc in order to obtain I1RMS120 and now set again 0 = 30 in order to obtain the firing angle = 150 and so on. Uv10 = 47 V () U3RMS (V) U12RMS (V) I1RMS (A)

0 47 82 0.48

30 46 81 0.47

60 42 74 0.43

90 36 63 0.37

120 26 47 0.27

150 15.5 27 0.16

180 4 7.2 0.043

Evaluate the various characteristic data of the converter and compare these with the theoretical values (see 1.5.2,page 15). () IRMS/IRMS0 0 1 30 0.98 60 0.89 90 0.77 120 0.56 150 0.33 180 0.09

Draw the transfer characteristic I1RMS/I1RMS0 = f().

The measured transfer characteristic coincides relatively well with the theoretical curve.

86

ver a20120201

DL DCA202.1 4) Recording on the oscilloscope Note Since the basic instrument set does not normally allow simultaneous measurements, the measures may have to be carried out successively. 4.1) Recording the load phase voltages U1 and U2. Oscilloscope setting. DC coupling; Yt mode. Trigger: AC Line. Channel 1(U1 voltage): 50 V/div, probe x10. Channel 2(U2 voltage): 50 V/div, probe x10. Oscillogram ( = 30)

Oscillogram ( = 60)

ver a20120201

87

DL DCA202.1 4.2) Recording the load line voltage U12 and the voltage UV3 at SCR V3 Oscilloscope setting. Assemble the measuring circuit according with detail (a). Channel 1 (U12 voltage): 50 V/div; probe x10. Channel 2 (UV3 voltage): 50 V/div; probe x10. Oscillogram ( = 30)

Oscillogram ( = 60)

88

ver a20120201

DL DCA202.1 EXPERIMENT N7

THREE-PHASE CONTROLLER W3C2,STAR OHMIC LOAD WITHOUT NEUTRAL Objectives: Recording voltage and current time profiles Voltage and current measurements Determination of various characteristic data Equipments: 1 DL 2605 SCR stack 1 DL 2613 Dc power supply 1 DL 2614 Voltage reference generator 1 DL 2617 Six pulse control unit 1 DL 2626 Mains transformer 1 DL 2628 Super-fast fuses (3x6.3 A) 1 DL 2635 Universal load 1 DL 2109T3PV Moving-iron voltmeter (125-250-500 V) 2 DL 2109T33 True rms meter 1 Dual-channel oscilloscope (preferred storage type) Circuit diagram

ver a20120201

89

DL DCA202.1 EXPERIMENT N7: CONTROLLER W3C2, OHMIC LOAD

90

ver a20120201

DL DCA202.1 Experiment procedure Assemble the circuit according with the foregoing topographic diagram, disregarding detail (a) at first. 1) Connections Connect the voltage reference generator DL 2614 and the control unit DL 2617 to the power supply +15V/0/-15V. Connect the output Uo of voltage generator to input Uc of the control unit. Connect the terminals L1/L2/L3/N (USYN) of the control unit respectively to terminals 2U1/2V1/2W1/2U3 of the mains transformer. Connect the pulse transformers 1,2,5 and 6 to gate/cathode circuit of the SCRs V1, V2, V5 and V6: socket marked with a dot to the gate. 2) Basic settings 2.1) Voltage reference generator DL 2614 EXT/INT switch on INT position. (0/+10V)/(0/10V) switch on (0/+10V) position. Setpoint potentiometer to 10 V. 2.2) Control unit DL 2617. Analog control switch on position. Control angle o switch on 0 position. Pulse shape switch on single pulse position. Select MAIN PULSE. Inhibit voltage UINH = 15 V (open). 3) Voltage and current measurements Supply the circuit and measure: 3.1) the rms value Uv10 of the supply voltage by the voltmeter P1; 3.2) the rms value I1RMS of the line 1 current by the ammeter P2; 3.3) the rms value U1RMS of the R1 load phase voltage by the voltmeter P3; 3.4) the rms value I2RMS of the line 2 current by the ammeter P4; 3.5) the rms value U2RMS of the R2 load phase voltage by the voltmeter P5. Enter the measured value as a function of the gate angle in 30 steps between 0 and 150in the following table.

ver a20120201

91

DL DCA202.1 HINT In order to set the gate angle it is possible the use of phase shift 0 in the control unit: 1) Set 0 =0 and Uc = 10 V to obtain the firing angle = 0 and carry out the measurements. 2) Set 0 = 30 to obtain the firing angle = 30. 3) Set now 0 = 60 to obtain the firing angle = 60 and, for example, note down the I1RMS60 value. 4) Set again 0 = 0 and adjust Uc in order to obtain I1RMS60 and now set again 0 =30 in order to obtain the firing angle = 90. 5) Set now 0 = 60 to obtain the firing angle = 120 and, for example, note down the I1RMS120 value. 6) Set again 0 = 0and adjust Uc in order to obtain I1RMS120 and now set again 0 = 30 in order to obtain the firing angle = 150 and so on. Uv10 = 47 V () U1RMS (V) U2RMS (V) I1RMS (A) I2RMS (A)

0 48 48 0.48 0.48

30 44.5 47.5 0.45 0.47

60 32 45 0.33 0.44

90 17 40 0.18 0.4

120 4.7 27 0.049 0.275

150 0.6 16.5 0.001 0.17

Evaluate the various characteristic data of the converter and compare these with the theoretical values (see 1.5.3,page 17). () IRMS/IRMS0 I2RMS/I2RMS0 0 1 1 30 0.94 0.98 60 0.96 0.92 90 0.38 0.83 120 0.1 0.57 150 0 0.35

Draw the transfer characteristic IRMS/IRMS0 = f() of the line currents.

The measured transfer characteristic coincides relatively well with the theoretical curve.

92

ver a20120201

DL DCA202.1 4) Recording on the oscilloscope Note Since the basic instrument set does not normally allow simultaneous measurements, the measures may have to be carried out successively. 4.1) Recording the load phase voltages U1 and U2. Oscilloscope setting. DC coupling; Yt mode. Trigger: AC Line. Channel 1(U1 voltage): 50 V/div, probe x10. Channel 2(U2 voltage): 50 V/div, probe x10. Oscillogram ( = 30)

Oscillogram ( = 60)

ver a20120201

93

DL DCA202.1 4.2) Recording the load line voltage U23 and the voltage UV5 at SCR V5 Oscilloscope setting. Assemble the measuring circuit according with detail (a). Channel 1 (U23 voltage): 50 V/div; probe x10. Channel 2 (UV5 voltage): 50 V/div; probe x10. Oscillogram ( = 30)

Oscillogram ( = 60)

94

ver a20120201

1996 - 2012 DE LORENZO SPA - Printed in Italy - All right reserved DE LORENZO SPA V.le Romagna, 20 - 20089 Rozzano (MI) Italy Tel. ++39 02 8254551 - Fax ++39 02 8255181 E-mail: info@delorenzo.it Web sites: www.delorenzoglobal.com - www.technical-education.it www.delorenzoenergy.com