Sie sind auf Seite 1von 2

2/19/13

SMS Gateway - Database user, MySQL


Search the manual:
Search

Overview

Quick start

Download

Manual

How to buy

FAQ

Contact Us
Contents | Search

OZEKI NG SMS Gateway - Product Guide


Home > Product Manual > Installation Guide > Users and applications > Database user > MySQL

SMS Gateway Home

SQL to SMS Gateway configuration - MySQL overview


Share |

Product Manual
Introduction SMS technology Installation Guide
Prerequisites Download Information Installation Steps Service Provider Connections Users and applications
Standard user SMPP user Database user MSSQL MySQL

Tw eet |

Share

Video tutorial:

How to send and receive SMS from MySQL

In this chapter you can learn how to configure the SMS gateway to be able to send and receive SMS messages using a MySQL database server. You will be provided with the installation steps, the configuration details such as the database connection string, database connection type, and with the recommended database table layout. To be able to send and receive SMS from a MySQL database you will need to install the MyODBC driver to your computer. This driver can be downloaded from the MySQL website. We recommended to use MyODBC v5.1, because it supports unicode characters. After the MyODBC driver has been installed on the computer, you need to configure a database user in the SMS Gateway. During the configuration the database connection type, you should choose is:

MyODBC v5 Database layout MyODBC driver installation


Oracle Sybase SQL Anyw here PostgreSQL Pervasive SQL Date Format Strings Scheduled SMS SQL templates Informix Access Video Connection string builder Keyw ords Batch processing SQL statements Polling technology Dynamic Keyw ords Dynamic SMPP parameters AutoreplyDatabase user Autoreply user AutoReplyEasy user File user E-mail user HTTP Client user Colour SMS user Appstarter user SMS Voting Outlook Mobile Service FTP user PDF user WCF Client User Forw arder user

Odbc

The database connection string you should use is:

Drive r={MySQ L O DBC 5.1 Drive r};Se rve r=127.0.0.1;Database =oze k ism s;Use r=oze k i;Password=abc123;O ption=4;

Please note that the database connection string should be modified to match your database. You should replace the "127.0.0.1" ip address to the hostname or ip address of your database server. Replace "ozekisms" to the name of you database. Replace "ozeki" and "abc123" to the username and password that can be used to connect to your database server. The connection string and the connection type should be entered on the Database user configuration form.

Linux

User Guide Developers Guide Examples and Solutions Appendix FAQ Feature list

Commercial Information Search

Contact Us!
If you wish to get further information, do not hesitate to contact us! E-mail: info@ozekisms.com If you have a technical question, please submit a support request on-line. Figure 1 - Specifying the connection string for the MySQL database After the database user has been configure in the SQL SMS gatway, the only thing left to do is to create the database tables ozekimessageout and ozekimessagin in your MySQL database. We recommend you to use the following table layout: MySQL create table script:

Callcenter developers

www.ozekisms.com/index.php?ow_page_number=168

If you are working on telephone solutions, please check out the Ozeki VoIP SIP SDK.

1/2

2/19/13
Ozeki VoIP SIP SDK. It can be used to create: Webphone solutions: - Adobe Flash video phone - Silverlight video phone - Web to web calls - Web to VoIP calls Custom SIP clients: - Silverlight SIP VoIP client - Flash SIP VoIP client - C# .net SIP VoIP client - ASP .net SIP VoIP client - Web based SIP VoIP client Custom VoIP solutions: - VoIP SIP softphones - VoIP call center clients - VoIP IVR systems - VoIP predictive dialer systems - VoIP auto dialer systems - VoIP call assistant - VoIP call recording systems - VoIP intercom solutions

SMS Gateway - Database user, MySQL


CREATE TABLE ozekimessagein ( id int(11) NOT NULL auto_increment, sender varchar(30) default NULL, receiver varchar(30) default NULL, msg text default NULL, senttime varchar(100) default NULL, receivedtime varchar(100) default NULL, operator varchar(100) default NULL, msgtype varchar(160) default NULL, reference varchar(100) default NULL, PRIMARY KEY (id) ) charset=utf8; ALTER TABLE ozekimessagein ADD INDEX (id) ; CREATE TABLE ozekimessageout ( id int(11) NOT NULL auto_increment, sender varchar(30) default NULL, receiver varchar(30) default NULL, msg text default NULL, senttime varchar(100) default NULL, receivedtime varchar(100) default NULL, reference varchar(100) default NULL, status varchar(20) default NULL, msgtype varchar(160) default NULL, operator varchar(100) default NULL, errormsg varchar(250) default NULL, PRIMARY KEY (id) ) charset=utf8; ALTER TABLE ozekimessageout ADD INDEX (id);

It is strongly recommended to maintain an index in the database for the 'id' field of the outgoing SMS table to support faster SQL updates.

If you wish you can add additional columns or you can modify these database tables. If you do please review the SQL templates used by the SMS gateway to make sure they will be compatible with the customized database table layout. Dig deeper! People who read this also read... Database User MyODBC v5 Database layout MyODBC drivers installation FAQ

Next page: MyODBC v5 Copyright 2000 - 2013 Ozeki Informatics Ltd. All rights reserved Software PBX for Windows | VoIP SDK | Legal information | Privacy policy | Terms of use Please, address your inquiries to info@ozekisms.com

www.ozekisms.com/index.php?ow_page_number=168

2/2

Das könnte Ihnen auch gefallen