Beruflich Dokumente
Kultur Dokumente
C ATA LOGUE
Viofor JPS
pg. 11
pg. 23
1041
Pad - Small Applicator 6S
pg. 15
1045
pg. 19
IR Elliptic Magnetic Light Applicator (infrared) pg. 20, pg. 37 RIR Elliptic Magnetic Light Applicator (red/infrared) pg. 21
1054, 1055
Spot Applicator S
pg. 16
1056
Spot Applicator Z
pg. 17
1040
Mat - Large Applicator 6S
pg. 14
1057
Flat Applicator for Pulsed Magnetic Field Therapy
pg. 17
pg. 14
1068
Adaptor Viofor JPS
pg. 26
1073
Med Stand
pg. 24
1095
pg. 24
Viofor JPS
1075
Carrying Bag 6S
pg. 38
1083
R Elliptic Magnetic-Light Applicator (red)
pg. 35
1076
Carrying Bag 3S
pg. 38
1043 1044
Light Stand
pg. 36
1074
Cushion
pg. 38
1079 1064
Ap65 Cable
pg. 23
1087
Table Stand
pg. 32
1071
Safety Goggles
pg. 18
1096
Ap30 Cable
pg. 24
pg. 29
1089
ST Cable
pg. 24
R Magnetic - Laser Applicator (red) pg. 28 IR Magnetic - Laser Applicator (infrared) pg. 28
1090
Power Supply ZAMS 01/2
pg. 38
1078
Service Set A
1091
Service Set B
pg. 38
Remote Control for Clinic/Delux Control Unit pg. 10, pg. 22 Remote Control for Classic Control Unit pg. 11
1092
RIR Single Panel Applicator (red/infrared)
pg. 38
1097 1080
RIR Dual-Panel Applicator (red/infrared)
pg. 18
1081
IR Dual-Panel Applicator (infrared)
1084 1082
pg. 34
1105
Adaptor VET G2
pg. 42
1106
pg. 42 3
Viofor JPS
medICAL DEVICES
There are two groups of Viofor JPS Systems for therapy and rehabilitation with magnetic field and light
PROFESSIONAL for professional users
medical room
home
medical room
For Pulsed Magnetic Field Stimulation purposes, Viofor JPS System generates pulsed electromagnetic field using complex shape pulses with multi-peak structure, resulting in multiple signals across a frequency spectrum. The shape of the signal: the two types of the saw-like shape of impulse. The frequencies are preset by the manufacturer. TheMagnetic signal consist of: the basic frequencies range: 180-195 Hz, the frequencies of the impulse packets range: 12,5-29 Hz, the packet groups range: 2,8-7,6 Hz, the series range: 0,08-0,3 Hz. Magnetic induction depends on the selected applicator as well as functional setting. The average magnetic induction values are far lower than those used in Pulsed Magnetic Field Therapy, for most Viofor JPS aplicators up to 100 T (see details in Table 2 pg. 9). Duration of the treatment is preset by the manufacturer when the desired functional setting is selected. Total duration of the treatment last 8 minutes, 10minutes or 12 minutes.
Clinic (Ref. 1033), Delux (Ref. 1035), Classic (Ref. 1031), Family (Ref. 1036), Family+ (Ref. 1037). Applicators: Mat Large Applicator 3S and 6S (Ref. 1040, Ref. 1042), Pad Small Applicator 3S i 6S (Ref. 1041, Ref. 1045), Spot Applicator S (Ref. 1056), Spot Applicator Z, (Ref. 1057), Elliptic Applicators (Ref. 1054, Ref. 1055), Large Applicator Frame Bed (Ref. 1060), Ring Applicators (Ref. 1059, Ref. 1058, Ref. 1098, Ref. 1099), Clinical Applicator (Ref. 1061).
Frequency: 5 40 Hz, in 5 Hz step Magnetic induction: 0,19 6,00 mT (set by the intensity level in the range of 0,5- 12) Duration of the treatment: 10 30 min, in 5 min step The shape of the signal: sinusoidal, triangular, rectangular Control Units: Clinic (Ref. 1033) Applicator: Flat Applicator for Pulsed Magnetic Field Therapy (Ref. 1068)
Viofor JPS
LED Therapy
LED Therapy home medical room
Average radiation power: depending on the selected control unit from a few mW (Clinic, Delux) orfrom10 % maximum radiation power tomaximum radiation power (Light, MagneticLight). Radiation frequency: 181.8 Hz (optical radiation isemitted at a constant frequency of 181.8 Hz, which is one of the main frequencies of pulsed magnetic field stimulation in the JPS System). Duration of the treatment: 8 min, 10min, 12 min orx2, x3, depends on selected control unit. The shape of the signal: Pulsed Magnetic Field Stimulation with the two types ofthesaw-like shape of impulse. Control units: MagneticLight (Ref. 1038), Light (Ref. 1034), Clinic (Ref. 1033), Delux (Ref. 1035). Applicators: Panel MagneticLight Applicators: (Ref. 1080, 1081, 1082, 1083, 1084, 1097), Elliptic Magnetic-Light Applicators (Ref. 1065, 1067, 1066, 1043, 1044).
LED Therapy is a form of phototherapy which entails the use of energy of unpolarized and incoherent light in the visible red and infrared light generated by high-energy LEDs. Maximum radiation power: from 400 mW to 6800 mW, depends on the applicator. Average radiation power: from 1mW, or 10% maximum radiation power to full maximum radiation power, depends on the control unit. Radiation frequency: 181.8 Hz (optical radiation is emitted at a constant frequency of 181.8 Hz, which is one of the main frequencies of Pulsed Magnetic Field Stimulation in the JPS System). Duration of the treatment: 1 30 min Control units: Light (Ref. 1034), S-PDT Laser (Ref. 1531), S-PDT MagneticLight (Ref. 1038). Applicators: magnetic-Light Panel Applicators (Ref. 1080, 1081, 1082, 1083, 1084), LED Therapy Spot Applicator (Ref. 1553).
Laser Therapy
Laser Therapy medical room
LED Therapy
home
medical room
Laser Therapy is a kind of light therapy which uses energy of coherent and monochromatic laser radiation in red and infrared radiation range, generated by semiconductor laser. Dose (density) of radiation energy: 199 J/cm2. Radiation frequency: 181.8 Hz (optical radiation isemitted at a constant frequency of 181.8 Hz, which is one of the main frequencies of pulsed magnetic field stimulation in the JPS System). Maximum radiation power: 30 mW for red radiation and 300 mW for infrared radiation. Average radiation power: from 1mW upto full maximum radiation power, depends ontheapplicator (continuous mode). Duration of the treatment: 10 30 min in 10 sec step. Control unit: Laser (Ref. 1531). Applicators: R Magnetic - Laser Applicator (Ref. 1551), IR Magnetic - Laser Applicator (Ref. 1552).
Pulsed Magnetic Field LED Therapy means using of Viofor JPS Pulsed Magnetic Field Stimulation and LED Therapy at the same time. Pulsed Magnetic Field LED Therapy in Viofor JPS System uses red and infrared optical radiation with parameters like in low-energy laser therapy. Synchronous Pulsed Magnetic Field LED Therapy - impulses of magnetic field and LED radiation are synchronized. Asynchronous Pulsed Magnetic Field LED Therapy - impulses of magnetic field and LED radiation are not synchronized. Maximum radiation power: from 400 mW to6800mW, depends on the selected applicator.
Viofor JPS
Laser Therapy
medical room
Pulsed Magnetic Field Laser Therapy means usage of Pulsed Magnetic Field Stimulation and Laser Therapy in the same time. Pulsed Magnetic Field Laser Therapy in Viofor JPS System uses red and infrared laser radiation with low energy parameters. Impulses of pulsed magnetic field and laser radiation arenot synchronized. Dose (density) of radiation energy: 1 99 J/cm2. Radiation frequency: 181.8 Hz (optical radiation is emitted at a constant frequency of 181.8 Hz, which is one of the main frequencies of Pulsed Magnetic Field Stimulation in the JPS System). Maximum radiation power: 30 mW for red radiation and 300 mW for infrared radiation. Average radiation power: from 1mW, up to full maximum radiation power, depends on the applicator (continuous mode). The shape of the signal: Pulsed Magnetic Field Stimulation with the two types of the saw-like shape of impulse. Duration of the treatment: separately sets for laser radiation from 1min to 10min in 10 sec step separately sets for pulsed magnetic field 8 min, 10min, 12 min. Control unit: Laser (Ref. 1531) combined with Clinic (Ref. 1033), Delux (Ref. 1035) or Classic (Ref. 1031). Applicators: R Magnetic - Laser Applicator (Ref. 1551), IR Magnetic - Laser Applicator (Ref. 1552).
The basis of PDT is the joint action of the photosensitizer, oxygen and light of an appropriate wavelength that is selectively absorbed by the photosensitizer. The result is a photodynamic action which enables the selective destruction of pathological tissue or the infected area. S PDT Viofor System allows completion of the procedure of the PhotoDynamic Therapy (PDT) in providing appropriate radiation dose for the treatment of a change qualified to the PhotoDynamic Therapy. The LED Therapy Spot Applicator can be used to PDT (PhotoDynamic Therapy) ensuring a correct dosage of light energy for photosensitizers with a wavelength of 632 nm. The PDT therapist decides what indications and energy dose and which photosensitizer should be used when carrying out the procedure. The equipment can be used for PDT that does not involve contact with the skin: the vulva, the male external genitals and oral mucosa. In recent years there has been a discernible rise in the use of PDT for the treatment of inflammatory states e.g.: acne vulgaris, crural ulcers, diabetic foot syndrome and inflammation of the external genitals. The equipment meets the technical criteria necessary for treatments accessible for non-endoscopic and non-contact application.
Control units: S PDT Laser (Ref. 1531), S PDT MagneticLight (Ref. 1038). Applicators: The LED Therapy Spot Applicator 632 nm (Ref. 1553).
Viofor JPS
Table 1. The combination of applicators 1040 1060 * * * * * * * * * 1042 1045 1054 1055 1041 1059
Mat - Large Applicator 3S Pad - Small Applicator 3S Mat - Large Applicator 6S Pad - Small Applicator 6S Elliptic Applicator Elliptic Applicator Ring Applicator - Large 65 cm Large Applicator- Frame Bed
* * *
Viofor JPS
2.1 x I min 1,05 max 25,2 2.1 x I min 1,05 max 25,2 4,1 x I min 2,05 max 49,2 10 x I min 5 max 120 100 x I min 50 max 1200 8.9 x I min 4,45 max 106,8 8.9 x I min 4,45 max 106,8 6,3 x I min 3,15 max 75,6 10 x I min 5 max 120 0.9 x I min 0,45 max 10,8 2.7 x I min 1,35 max 32,4 0.9 x I min 0,45 max 10,8 2.7 x I min 1,35 max 32,4 2.7 x I min 1,35 max 32,4
23 x I min 11,5 max 276 23 x I min 11,5 max 276 45 x I min 22,5 max 540 112 x I min 56 max 1344 1120 x I min 560 max 13440 100 x I min 50 max 1200 100 x I min 50 max 1200 70 x I min 35 max 840 100 x I min 50 max 1200 10 x I dla L min 5 max 120 30 x I dla H min 15 max 360 10 x I min 5 max 120 30 x I min 15 max 360 30 x I min 15 max 360
Magnetic - Laser Applicator Ring Applicator Small 30 cm Ring Applicator Large 65 cm Ellastic Ring Applicator 30 cm Ellastic Ring Applicator 40 cm
D 50%
2,3 cm 2,7 cm
Notes
PN* for 1 disc PN* for 2 discs instack
Accuracy 10% I *PJ intensity level sets on Viofor JPS Control Unit (range: 0,5-12) homogeneous magnetic field; it is measured in geometric center inside the applicator; homogeneity is constant with accuracy 5% inside 70% of applicator capacity. *PN heterogeneous magnetic field; it is measured on the applicator surface in place with the strongest induction
D50% approximate distance from applicator surface where is 50% induction of maximum value.
Ref.
1035
home
medical room
Pulsed Magnetic Field LED Therapy Pulsed Magnetic Field Stimulation parameters: as above regulation of light energy parameters by selecting the intensity level of the magnetic field works together with Elliptic MagneticLight Applicators (Ref. 1065, 1066, 1067) works together with the RIR Single Panel Applicator (Ref. 1097) CARRIES OUT THE FOLLOWING FUNCTIONS: communication with the User via the Menu possibility of making use of inbuilt sets of application parameters programming and recording the function settings timing the duration of the treatment treatment counter placebo mode system for recognizing the attached applicators selecting the language: PL, EN, DE, FR infra-red remote control four levels regulation of the acoustic signal energy saving stand by mode Equipped with: graphic display with LCD screen and function keyboard two sockets for the Pulsed Magnetic Field Stimulation applicators one socket for the magnetic-light applicators supply voltage switch 230/115 V
Dane techniczne TECHNICAL DATA wymiary: Type of controll unit Supply voltage and frequency Power consumption in stand-by mode Maximum power consumption Max. output voltage on controll unit socket Working mode Admissible working temperature / humidity Output sockets of controll unit for connecting applicators Safety class Protection against water Maximum dimensions Weight
microprocessor 230 V/115 V 10 %; 50 Hz/60 Hz <5 VA <26 VA 15 V on G1 and G2 sockets 25 V on G3 socket continuous running +10 +40 C / max 80 % two sockets jack 6,3 mm one round 6-pin socket II IP 40 (not waterproof) 32 cm x 27 cm x 17,5 cm 3,4 kg
carries out the following types of therapy: Pulsed Magnetic Field Stimulation in the JPS System three programmes: P1, P2, P3 three types of application: M1, M2, M3 duration of the treatment: preset by the manufacturer 8min/10min/12 min multiplier of the applicators running time: x1, x2, x3 thirteen levels of application intensity: from 0.5 to 12 automatic change in the direction of the magnetic field works together with Pulsed Magnetic Field Stimulation applicators
Ref.
1077
Delux
control unit
TECHNICAL DATA Supply voltage Maximum dimensions two AAA batteries. 17,6 cm x 6,7 cm x 1,7 cm
Remote control for Viofor JPS Clinic/ Delux Control Unit allows remote control and programming with the use of pre-set application parameters and reading the treatment counter. In Delux Control Unit the remote control is not active for the Pulsed Magnetic Field Therapy.
10
home / professional
Ref.
1031
home
medical room
Dane techniczne wymiary: TECHNICAL DATA Type of control unit Supply voltage and frequency Power consumption in stand-by mode Maximum power consumption Max output voltage on control unit socket Working mode Admissible working temperature/humidity Output sockets of control unit (for connecting applicators) Safety class Protection against water Maximum dimensions Weight microprocessor 230 V/115 V 10%; 50 Hz/60 Hz <8 VA <15 VA 25 V on all sockets continuous running +10 +40 C / max 80% three sockets jack 6,3 mm II IP 40 (not waterproof) 32 cm x 27 cm x 17,5 cm 2,5 kg
Equipped with: digital display showing the duration of the application function keyboard three sockets for Pulsed Magnetic Field Stimulation applicators supply voltage switch 230/115 V
Ref.
1072
Remote control for Viofor JPS Classic Control Unit allows remote control and programming with the use of pre-set application parameters and reading the treatment counter.
control unit
TECHNICAL DATA Supply voltage Maximum dimensions two AAA batteries. 17,6 cm x 6,7 cm x 1,7 cm
home / professional
11
Ref.
1036
home
Ref.
1037
carries out the following types of therapy: Pulsed Magnetic Field Stimulation in the JPS System types of application: Wellness or Therapy adapted to the physical condition of the user: Healthy, Sick, Child adapted to the time of day: Day, Night periods of use by adults age brackets for children duration of the treatment: preset by the manufacturer 10min/12 min multiplier of the application running time: x1, x2 automatic change in the direction of the magnetic field level of intensity (value of magnetic induction) adapted to selected function settings and the possibility of regulating them works together with selected magnetic field applicators marked with the symbolF CARRIES OUT THE FOLLOWING FUNCTIONS: communication with the User via the Menu programming and recording the function settings (Family+ only) recognition of the attached applicators timing the duration of the application energy saving: turns off after two minutes of inactivity EQUIPPED WITH: graphic display with LCD screen and function keyboard Power Supply for medical equipment (Ref. 1094) possibility of plugging in to an in-car lighter (Ref. 1093) possibility of being powered by the Battery Power (Ref. 1103) one socket for the Pulsed Magnetic Field Stimulation applicators
home
TECHNICAL DATA Type of control unit Supply voltage microprocessor 10-15 V DC, 1,6 A Switching Power Suooly MPU30-106 Battery Power BS-01 Plug-in adaptor to in-car lighter 5 VA 15 VA max. 15 V continuous running +10 +40 C / max 80% IP 40 (not waterproof) 32 cm x 27 cm x 10,5 cm 1,4 kg
Maximum power consumption Maximum power consumption Max output voltage on control unit socket Working mode Admissible working temperature / humidity Protection against water Maximum dimensions Weight
12
home / professional
Ref.
1094
TECHNICAL DATA Supply parameters Output parameters Safety class 100-240 V, 47-63 Hz, 0.9-0.34 A 15 V DC, 2 A I
Ref.
1103
TECHNICAL DATA AGM battery Parameters Supply conditions 12 V/3,4 Ah (types: SB 3,4-12 or LC-R123R4PU) from the Switching Power Supply MPU30-106 15 V/30W T 3,15 A
Fuse
Ref.
1093
TECHNICAL DATA Car cigarette lighter plug Cable with plug 12 V TPC 600N 5,5/2,1 mm; lengthof cable 1,5 m
home / professional
13
medical room
home
For the whole body treatment. Generates pulsating heterogeneous magnetic field. Portable, two-colour, folded into three. Can be combined with other applicators given in the table via the Viofor JPS adaptor.
APPLICATION OF LARGE APPLICATOR MAT For the whole body treatment. Activity: analgesic, regenerative, improving peripheral activity, antispastic. Rehabilitation and therapy spondylosis of the spine and osteoarticular system of the upper and lower limbs rheumatoid arthritis (ra) ankylosing spondylitis osteopenia and osteophorosis extensive burns extensive bedsores conditions after apoplexy
degenerative diseases of the nervous system, accompanied by spasticity neuroses sleep disorders stress, particularly after long-term psychic/mental tension concentration disturbances after sport training in biological regeneration
Space application of the mat is between the sections 2 to 5. Sections 1 and section 6 do not generate pulsating magnetic field.
Ref.
1040
Delux
control unit
TECHNICAL DATA Dimensions of Mat- large applicator 3S Dimensions of Mat- large applicator 3S after fold Magnetic field induction (peak peak): Magnetic field frequency 180 cm x 65 cm x 3 cm 65 cm x 60 cm x 8,5 cm 11,5 T 276 T
control unit
Classic
control unit
Family
control unit
Ref.
1042
Clinic
control unit
Delux
control unit
Portable, folded into six. Through the code system works properly with Clinic, Deluxe, Classic or the Family and Family+ control unit.
Classic
control unit
Family
control unit
TECHNICAL DATA Dimensions of Mat- large applicator 6S Dimensions of Mat- large applicator 6S - after fold Magnetic field induction (peak peak): Magnetic field frequency 180 cm x 55 cm x 1,8 cm 55 cm x 30 cm x 13 cm 11,5 T 276 T 0,08 195 Hz (details on pg. 5.)
14
home / professional
medical room
home
This applicator is to be used topically. Generates pulsating heterogeneous magnetic field, two-colour. Can be combined with other applicators given in the Table 1. via the Viofor JPS adaptor. APPLICATION OF SMALL APPLICATOR PAD Topical activity: analgesic, regenerative, improving peripheral circulation, antispastic.
Rehabilitation and therapy joint injuries extra articular rheumatism (so-called fibromyalgia) soft tissue injuries conditions after injury (interruption) to the continuity of tissue (including post-surgical) migraines conditions after bone crack and fracture conditions after operations on bone structure pseudarthrosis conditions after injury with or without damage to skin continuity burns bedsores diabetic and atherosclerotic angiopathy crural ulceration haemathomas conditions after apoplexy degenerative diseases of the nervous system, accompanied by spasticity
Ref.
1041
Delux
control unit
Classic
control unit
Family
control unit
TECHNICAL DATA Dimensions of Pad- small applicator 3S Magnetic field induction (peak peak) Magnetic field frequency 50 cm x 28 cm x 3 cm 22,5 T 540 T 0,08 195 Hz, (details on pg. 5.)
Ref.
1045
Delux
control unit
Classic
control unit
TECHNICAL DATA Dimensions of Pad- small applicator 6S Magnetic field induction (peak peak) Magnetic field frequency 55 cm x 27 cm x 1,8 cm 22,5 T 540 T 0,08 195 Hz (details on pg. 5.)
Family
control unit
home / professional
15
Ref.
medical room
home
Elliptic Applicators used individually interacted identically. When combining two Elliptic Applicator the different colours and flat side facing each other should be used. APPLICATION OF ELLIPTIC AND SPOT APPLICATORS Topical activity: analgesic, regenerative, improving peripheral circulation Rehabilitation and therapy joint injuries extra articular rheumatism (so-called fibromyalgia) soft tissue injuries conditions after injury (interruption) to the continuity of tissue (including post-surgical) migraines conditions after bone crack and fracture conditions after operations on bone structure pseudarthrosis conditions after injury with or without damage to skin continuity burns bedsores diabetic and atherosclerotic angiopathy crural ulceration haemathomas Dentistry periapical tooth inflammation nerve damage, complications after anaesthesia complication after dental surgery complication after endodontic treatment dry socket enhanced of orthodontic treatment Elliptic applicators work properly with Clinic, Deluxe, Classic or the Family and Family+ control units through the code system.
Clinic
control unit
Delux
control unit
Ref.
1055
Classic
control unit
Family
control unit
TECHNICAL DATA Dimensions Magnetic field induction (peak peak) Magnetic field frequency Application area 9,5 cm x 7,5 cm x 2 cm 50 T 1200 T 0,08 195 Hz (details on pg. 5.) about 20 cm2 (a circle with a diameter about 5 cm)
This applicator is to be used topically. Fastened with a belt on hands and legs or other places of application. Generates pulsating heterogeneous magnetic field. Produced in two different colours. Colour is important when combining two applicators via adaptor.
16
home / professional
Spot Applicator S
This applicator is to be used for spot application. It is used in cases when a narrow beam of significant magnetic field is required.
home medical room
Pulsed Magnetic Field Stimulation
Ref.
1056
Clinic
control unit
Delux
control unit
Classic
control unit
TECHNICAL DATA Outer diameter Length Magnetic field induction (peak peak) Magnetic field frequency: Application area 1,6 cm 17 cm 56 T 1,34 mT 0,08 Hz 195 Hz (details on page 5.) about 1 cm2
Family
control unit
APPLICATION The spectrum of usage is analogue as an elliptic applicator - page 16. Through the code system works properly with Clinic, Deluxe, Classic or the Family and Family+ control units.
Spot Applicator Z
Applicator is used for spot application. Used in cases when a narrow beam of significant magnetic field is required.
home medical room
Pulsed Magnetic Field Stimulation
Ref.
1057
Clinic
control unit
Delux
control unit
Classic
control unit
TECHNICAL DATA Outer diameter Length Magnetic field induction (peak peak) Magnetic field frequency: Application area 1,6 cm 17 cm 560 T 13,4 mT 0,08 Hz 195 Hz (details on page 5.) about 1 cm2
Family
control unit
Induction of magnetic field is ten times greater than spot applicator S. Applicator is used after doctors or physiotherapists recommendation. APPLICATION The spectrum of usage for spot applicators is analogue as an elliptic applicators - pg. 16. Works properly with Clinic, Deluxe, Classic control units.
home / professional
17
Ref.
1097
APPLICATION Topical activities: analgesic, regenerative, improving peripheral circulation, Osteoarticular system diseases degenerative join disease pain syndromes of various aethiology overload (strain) and injuries of osteoarticular system bone fractures and delayed union of fractured bone chronic and subacute arthritis rheumatoid arthritis (RA) and ankylosing spondylitis Soft tissue diseases soft tissue injuries syndromes due to strain of muscles and periarticular soft tissues periarthritis Neurological diseases neuralgia (intercostal neuralgia, trigeminal neuralgia, post herpetic neuralgia) sciatica diabetic neurophaty Skin diseases delayed healing of wound, ulceration and bedsore acne vulgaris herpes zoster Can be used in dermatology and aesthetic medicine. APPLICATION for topical usage for a larger areas of the body the contact usage or close contact for fixing on the table stand RIR Panel Applicator (red/infrared) works with Clinic and Delux control units.
home
medical room
Clinic
control unit
Delux
control unit
TECHNICAL DATA Red radiation wavelength Infrared radiation wavelength Maximum red radiation power (in impulse) Maximum infrared radiation power (in impulse) Application area Safety class of radiation Type of connection Weight Dimensions Fixing Magnetic field induction (peak peak, at the middle of the applicator): Magnetic field frequency 630 nm 855 nm 250 mW 1700 mW 280 cm2 3R 6-pin terminal 1,7 kg 24,5 cm x 18,2 cm x 11,5 cm at the Table Stand 35 T 840 T 0,08 Hz 195 Hz (details on pg. 5.)
RIR Single-Panel Applicator (red/infrared) is used for Pulsed Magnetic Field LED Therapy. It generates LED radiation which is synchronized with a pulsed magnetic field of JPS System.
Ref.
1071
Table Stand
home
Table Stand is designed for affixing the RIR Panel Applicator (Ref. 1097). The stand enables the non-contact usage of panel applicator without the help of a third party.
18
home / professional
Delux
control unit
TECHNICAL DATA Supply voltage Type of connection Indicator of operating mode Safety class of radiation Dimensions from Clinic, Delux, Light control unit or from Power distributor ZAMS01/2 6-pin terminal flashing LED on the top of applicator, a color of the indicator depends on type of applicator 3R 9,2 cm x 7,5 cm x 3,1 cm
Ref.
1065
home
Clinic
control unit
Delux
control unit
TECHNICAL DATA Red radiation wavelength Maximum red radiation power (in impulse) Application area Magnetic field induction (peak peak) Magnetic field frequency Indicator of operating mode 630 nm 210 mW about 20 cm2 (a circle with a diameter about 5 cm) 50 T 1200 T 0,08 195 Hz (details on pg. 5.) flashing orange LED
home / professional
19
Ref.
As a result of the infrared light applied mainly in osteoarticular system, soft tissues and neurological diseases. Osteoarticular system diseases degenerative join disease pain syndromes of various aethiology overload (strain) and injuries of osteoarticular system bone fractures and delayed union of fractured bone chronic and subacute arthritis rheumatoid arthritis (RA) Soft tissue diseases soft tissue injuries syndromes due to strain of muscles and periarticular soft tissues periarthritis Neurological diseases neuralgia (intercostal neuralgia, trigeminal neuralgia, post herpetic neuralgia) sciatica diabetic neurophaty
home
Clinic
control unit
Delux
control unit
TECHNICAL DATA Infrared radiation wavelength Maximum infrared radiation power (in impulse) Application area Magnetic field induction (peak peak) Magnetic field frequency Indicator of operating mode 855 nm 1440 mW about 20 cm2 (a circle with a diameter about 5 cm) 50 T 1200 T 0,08 195 Hz (details on pg. 5.) flashing green LED
Applicator designed for synchronic Pulsed Magnetic Field LED Therapy using infrared radiation. Tissue penetration of the light is up to several cm. The spectrum of usage is analoque as Elliptic Applicator (application of magnetic field, p. 16).
20
home / professional
Ref.
1067
home
Clinic
control unit
Delux
control unit
TECHNICAL DATA Red radiation wavelength Infrared radiation wavelength Maximum red radiation power (in impulse) Maximum infrared radiation power (in impulse) Application area Magnetic field induction (peak peak) Magnetic field frequency Indicator of operating mode 630 nm 855 nm 105 mW 720 mW about 20 cm2 (a circle with a diameter about 5 cm) 50 T 1200 T 0,08 195 Hz (details on pg. 5.) flashing yellow LED
Ref.
1078
Classic
control unit
TECHNICAL DATA Supply voltage and frequency Input signal Maximum power consumption Output signal: Impulses which are synchronized with signal from control unit Admissible working temperature/humidity Safety class Protection against water Working mode Maximum dimensions Weight 230 V/115 V 10 %; 50 Hz/60 Hz from Classic Control Unit Unit 12 VA 21 V 0,3 V +10 +40 C / max 80% II IP 40 (not waterproof) continuous running 20 cm x 9,5 cm x 7 cm 0,9 kg
home / professional
21
Ref.
1033
medical room
TECHNICAL DATA Type of control unit Supply voltage and frequency Power consumption in stand-by mode Maximum power consumption Max output voltage on control unit socket Working mode Admissible working temperature/humidity Output sockets of control unit (for connecting applicators) Safety class Protection against water Maximum dimensions Weight microprocessor 230 V/115 V 10%; 50 Hz/60 Hz <5 VA <40 VA 15 V on G1 and G2 sockets 25 V on G3 socket continuous running +10 +40 C / max 80% two sockets jack 6,3 mm one round 6-pin socket II IP 40 (not waterproof) 32 cm x 27 cm x 17,5 cm 3,4 kg
Pulsed Magnetic Field LED Therapy Pulsed Magnetic Field Stimulation parameters: as above regulation of light energy parameters by selecting the intensity of the magnetic field works together with Elliptic MagneticLight Applicators (Ref. 1065, 1066, 1067) works together with the RIR Single Panel Applicator (Ref. 1097) Pulsed Magnetic Field Therapy three wave shapes: sinusoidal, triangular, rectangular regulation of frequency from 5-40 Hz with 5 Hz step regulation of the treatment time, from 10 30 min with 5 min step thirteen application intensity levels, from 0.5 to 12 works together with Flat Applicator for Pulsed Magnetic Field Therapy CARRIES OUT THE FOLLOWING FUNCTIONS: communication with the User via the Menu possibility of making use the inbuilt sets of application parameters (for Pulsed Magnetic Field Stimulation) possibility of programming and recording function settings timing the duration of the treatment individual treatment counter for: -Pulsed Magnetic Field Stimulation and Pulsed Magnetic Field LED Therapy - Pulsed Magnetic Field Therapy placebo mode system for recognizing the attached applicators selecting the language: PL, EN, DE, FR infra-red remote control four levels of regulation of the acoustic signal energy saving stand by mode EQUIPPED WITH: graphic display with LCD screen and function keyboard two sockets for Pulsed Magnetic Fild Stimulation applicators one socket for the Magnetic-Light Applicators or the Pulsed Magnetic Field Therapy applicator supply voltage switch 230/115 V
carries out the following therapy: Pulsed Magnetic Field Stimulation in the JPS System three programmes: P1, P2, P3 three types of application: M1, M2, M3 duration of the treatment: preset by the manufacturer 8min/10min/12 min multiplier of the application running time: x1, x2, x3 thirteen levels of application intensity: from 0.5 to 12 automatic change in the direction of the magnetic field works together with Pulsed Magnetic Field Stimulation applicators
Ref.
1077
TECHNICAL DATA Supply voltage and frequency two AAA batteries. Maximum dimensions 17,6 cm x 6,7 cm x 1,7 cm
Clinic
Delux
22
professional
Clinical Applicator
Clinical Applicator is a set of Large Applicator-Frame Bed (Ref. 1060) and Ring Applicator Large 65 cm (Ref. 1059) and Cushion (Ref. 1079). Enable simultaneous application pulsating magnetic field generated by Large Applicator-Frame-Bed as well as Ring Applicator. Simultaneous application increases efficacy of the treatment. Works with Clinic, Delux, Classic control units. APPLICATION The spectrum of usage is analogue as an Large Applicator Frame Bed and Ring Applicator Large 65 cm (pg. 24). 1 2 3 4
Pulsed Magnetic Field Stimulation
Ref.
1061
medical room
Clinic
control unit
Delux
control unit
Classic
control unit
Space application of the Large Applicator - Frame Bed is between the sections 2 to 5. Sections 1 and section 6 do not generate pulsating magnetic field.
Ref.
1060
Delux
control unit
Classic
control unit
medical room
control unit
TECHNICAL DATA Maximum dimensions Magnetic field induction (peak peak) Magnetic field frequency 196 cm x 49 cm x 55 cm 11,5 T 276 T 0,08 195 Hz (details on pg. 5.)
Cushion
Ref.
1079
For convenient positioning of the patient on the Large Applicator Frame Bed. It is not an active applicator.
Dimensions 25 cm x 40 cm
Ref.
1064
Connecting cable with plugs terminated a jack 6,3 mm with appropriate markings direction of the connection.
Length 3m
professional
23
Ref.
1059
Clinic
control unit
Delux
control unit
APPLICATION OF RING APPLICATORS Topical activities: analgesic, regenerative, improving peripheral circulation, antispastic. Rehabilitation and therapy joint injuries extra articular rheumatism (so-called fibromyalgia) soft tissues injuries conditions after injuries (interruption) to the continuity of tissue (including post-surgical) migraines conditions after bone crack and fracture conditions after operation on bone structure pseudarthrosis conditions after injury with or without skin continuity burns bedsores diabetic angiopathy atherosclerotic angiopathy crural ulceration haematomas conditions after apoplexy degenerative diseases of the nervous system, accompanied by spasticity
Classic
control unit
TECHNICAL DATA External dimensions Internal diameter Magnetic field induction (peak peak) Magnetic field frequency 85 cm x 69 cm x 40 cm 60 cm 5 T 120 T 0,08 195 Hz (details on pg. 5.)
Used only with the Large Applicator Frame-Bed. Equipped with mechanism to be easily moved along the tracks of the frame bed applicator. Generates pulsating homogenous electromagnetic field with the lines parallel to the coil axis and to the patients body. Topical application or together with large applicator frame-bed for whole body treatment. Works with Clinic, Delux, Classic control units.
Ref.
1096 1089
Ref.
1095
Med Stand
Ref.
Intended to accommodate Viofor JPS control units and accessories Features and functions: two swivel shelves for control units height adjustable shelves shelf for accessories mobile base (rollers), with lockable castors
Ref.
1073
24
professional
Ref.
1058
medical room
Clinic
control unit
home
Classic
control unit
Delux
control unit
TECHNICAL DATA External dimensions Internal diameter Magnetic field induction (peak peak) in connection to socket L Magnetic field induction (peak peak) in connection to socket H Magnetic field frequency 34,3 cm x 34 cm x 22 cm 26 cm 5 T 120 T 15 T 360 T 0,08 195 Hz (details on pg. 5.)
Ref.
1098
medical room
Clinic
control unit
home
Classic
control unit
Delux
control unit
Ref.
1099
The applicator is equipped with a portable soft shelf that allows the positioning of the body in the area of homogeneous electromagnetic field and comfortable position during the procedure. Applicators work with Clinic, Deluxe and Classic control units.
professional
25
Ref.
Clinic
control unit
TECHNICAL DATA Magnetic field induction (peak peak) forsingle disk Magnetic field induction (peak peak) fortwo stacked disks Frequency Duration of treatment Shape of signal Diameter of single disk Height of single disk 0,19 mT 4,56 mT 0,25 mT 6,0 mT 5 - 40 Hz, in 5 Hz step 10 - 30 min, in 5 min step sinusoidal, triangular, rectangular 16,5 cm 3,3 cm
APPLICATION Osteoarticular system diseases delayed synostosis complication after endoprothesisplasty of hip joint pseudarthrosis complications during surgical bone elongation osteophorosis degenerative diseases and arthritis conditions after bone crack and fracture conditions after joint injuries Peripheral vascular diseases diabetic angiopathy atherosclerotic angiopathy Skin and soft tissue diseases wounds of skin and soft tissue bacterial infections of skin and soft tissue burns keloid crural ulceration and trofic lesion
The applicator is designed to perform the topical treatment of Pulsed Magnetic Field Therapy on selected parts of the body. The applicator consists of two identical interconnected flat application elements - disks. Each disk generates a heterogeneous magnetic field. Double-colour cover of disks determines the polarity of the magnetic field generated by each element, which is essential for the process (methodology) of therapy. Applicator for Pulsed Magnetic Field Therapy works exclusively with the Clinic Control Unit and requires a qualified medical stuff.
Ref.
1531
medical room
TECHNICAL DATA Type of control unit Supply voltage and frequency Maximum power consumption Power consumption in stand-by mode Maximum output voltage of laser therapy Maxaximum output voltage of magnetic field laser therapy Adjustable output power Laser radiation frequency Duration of treatment Working mode Admissible working temperature/humidity Safety class Maximum dimensions Weight microprocessor 230 V/115 V 10%; 50 Hz/60 Hz 12 VA 3 VA 5,5 V 15 V From 1 mW to maximum output power of applicator 181,8 Hz od 1 min do 30 min continuous running +10 +40 C / max 80% II 32 cm x 27 cm x 17,5 cm 2,4 kg
medical room
professional
27
Ref.
1551
R Magnetic Laser Applicator (red) generates red laser radiation by using three separate semiconductors lasers. APPLICATION skin diseases e.g. purulence, fester, acne vulgaris crural ulceration bedsores herpes zoster
medical room
Laser
control unit
TECHNICAL DATA Wavelength Maximum output power Safety class of radiation Output laser spot diameter Weight Magnetic field induction (peak peak) Magnetic field frequency Dimensions 635 nm 30 mW 3B 3 4,5 mm 235 g 50 T 1200 T 0,08 195 Hz (details on pg. 5.) 16,0 cm x 3,6 cm x 3,6 cm
Ref.
1552
medical room
Laser
control unit
IR Magnetic Laser Applicator (infrared) generates infrared laser radiation by using one semiconductors laser. Users visible pilot red beam generated from another semiconductor laser is present during lasers work. APPLICATION pain syndromes of various aethiology degenerative joint and spine disease overload (strain) and injuries of asteoarticular system
TECHNICAL DATA Wavelength Maximum output power Safety class of radiation Output laser spot diameter Weight Magnetic field induction (peak peak) Magnetic field frequency Dimensions 808 nm, pilot 650 nm 300 mW 3B 3,0 4,5 mm 235 g 50 T 1200 T 0,08 195 Hz (details on pg. 5.) 16 cm x 3,6 cm x 3,6 cm
28
professional
Ref.
1553
medical room
S-PDT
control unit
TECHNICAL DATA Application area Output spot diameter Wavelength Maximum output power Safety class of radiation Type of connection 2,3 cm2 17 mm 632 nm 400 mW 3R circular 12-pin terminal for Viofor S PDT MagneticLight controller flat 8-pin terminal for Viofor S PDT Laser controller 225 g 16 cm x 3,6 cm x 3,6 cm
Weight Dimensions
Safety Goggles
Professional safety goggles with protective optical filter for protection against red and infrared radiation emitted by LASER and LED applicators.
Ref.
1086
professional
29
Ref.
1034
LED Therapy
medical room
TECHNICAL DATA Type of control unit Supply voltage and frequency Maximum power consumption Power consumption in stand-by mode Maximum output voltage of light impulse signal Max output voltage of magnetic field impulse signal Frequency of light signal in LIGHT mode Duration of light signal Adjustable treatment time Frequency and duration of output signal in MAGNETIC&LIGHT mode Working mode Admissible working temperature/humidity Safety class Protection against water Maximum dimensions Weight microprocessor 230 V/115 V 10%; 50 Hz/60 Hz 85 VA 6 VA 21,5 V 15 V 181,8 Hz 10% - 100% 1 30 min it depends on settings of Clinic, Delux orClassic controller continuous running +10 +40 C / max 80% II IP 40 (not waterproof) 32 cm x 27 cm x 17,5 cm 3,4 kg
CARRIES OUT THE FOLLOWING FUNCTIONS: communication with the User via the Menu recognition of the attached applicators indication of the lack of an applicator possibility of selecting a section of the panel applicator possibility of setting the time for the duration of a treatment [min] when using the LIGHT work mode possibility of setting the average power [mW] when using the LIGHT work mode calculating the dose (density) of energy [J/cm2] automatically calculates the surface energy density when using the LIGHT work mode timing the duration of the application energy saving stand by mode EQUIPPED WITH: text and numerical display on LCD screen and function keyboard system for detecting Pulsed Magnetic Field Stimulation impulses in MAGNETIC & LIGHT mode, ensuring synchronous impulses of radiation and magnetic field acoustic signal for safety, the signal cannot be turned off during the duration of a treatment socket to connect the panel magnetic-light applicators socket to connect the elliptic magnetic-light applicators socket for coupling with the Viofor JPS Clinic, Delux, Classic Control Unit ventilation vents in the casing to keep the interiors cool supply voltage switch 230/115 V
Viofor JPS Light Control Unit with proper equipment can realize LED Therapy as well as Pulsed Magnetic Field LED Therapy. It works in LIGHT mode and MAGNETIC&LIGHT mode. Pulsed Magnetic Field LED Therapy application can be provided by linking Viofor JPS Light Control Unit with any of the Clinic, Deluxe or Classic Control Units by using original cable connecting ST Cable (Ref. 1090).
Therapy LED therapy Synchronous Pulsed magnetic Field LED Therapy Asynchronous Pulsed magnetic Field LED Therapy
Accesories Viofor JPS Light Control Unit (Ref. 1034) Panel Magnetic-Light Applicators (Ref. 1080, 1081, 1082, 1083, 1084)
Viofor JPS Light Control Unit (Ref. 1034) MAGNETIC Viofor JPS Clinic, Delux, Classic Control Units (Ref. 1033, 1035, 1031) & LIGHT Panel Magnetic-Light Applicators (Ref. 1080, 1081, 1082, 1083, 1084) Elliptic Magnetic-Light Applicator (Ref. 1065, 1066, 1067) LIGHT Viofor JPS Light Control Unit (Ref. 1034) Viofor JPS Clinic, Delux, Classic control units (Ref. 1033, 1035, 1031) Panel Magnetic-Light Applicators (Ref. 1080, 1081, 1082, 1083, 1084)
30
professional
Ref.
1038
LED Therapy
medical room
TECHNICAL DATA Type of control unit Supply voltage and frequency Max. power consumption Power consumption in stand-by mode Max. output voltage of light impulse signal Max. output voltage of Magnetic Field impulse signal Frequency of light signal in the LED Therapy mode Duration of light signal in the Led Therapy mode and asynchronic Magnetic Field LED Therapy mode Adjustable treatment time Magnetic field adjustment Working mode Admissible working temperature/humidity Safety class Protection against water Max. dimensions Weight microprocessor 230 V/115 V 10%; 50 Hz/60 Hz 60 VA 2 VA +22 V 15 V 181,8 Hz 10% - 100% 1,2 lub 3 x 10minutes 13 steps continuous running +10 +40 C / max 80% II IP 40 (not waterproof) 32 cm x 27 cm x 17,5 cm 3,4 kg
medical room
Viofor S PDT MagneticLight Control Unit with LED Therapy Spot Applicator (Ref. 1553) is designed to perform topical LED Therapy. It is the complete set for PhotoDynamic Therapy. It ensures adequate dose of optical radiation exposure to changes qualified to the PhotoDynamic Therapy.
Ref. 1553 pg. 29
Accesories Viofor JPS MagneticLight Control Unit (Ref.1038) Panel Magnetic-Light Applicators (Ref. 1080, 1081, 1082, 1083, 1084) Viofor JPS MagneticLight Control Unit (Ref.1038) Panel Magnetic-Light Applicators (Ref. 1080, 1081, 1082, 1083, 1084) Elliptic Magnetic-Light Applicators (Ref. 1043, 1044, 1066) Viofor JPS MagneticLight Control Unit (Ref. 1038) Panel Magnetic-Light Applicator (Ref. 1080, 1081, 1082, 1083, 1084)
professional
31
medical room
Panel magnetic-light applicators are used for exposing large areas of the body. They are used for: LED Therapy synchronous or asynchronous Pulsed Magnetic Field LEDTherapy The applicators are designed for using close to the patients body. All applicators should be affixed to Light Stand (Ref. 1087). All applicators are equipped with fans and air holes for cooling the interior.
Ref.
1087
Ref.
1080
Light
control unit
Magneti -Light c
control unit
medical room
TECHNICAL DATA Red radiation wavelength Maximum red radiation power (in impulse) from two sections Application area of one section Application area of two section) Safety class of radiation Type of connection 630 nm 1000 mW 280 cm2 560 cm 3R 15-pin terminal for Light Control Unit 12-pin terminal for MagneticLight Control Unit) 3,2 kg 24,5 cm x 18,2 cm x 11,5 cm at the LIGHT Stand 35 T 840 T 0,08 195 Hz (details on pg. 5.)
2
Applicator consists of two separate sections. The panels are permanently linked by the cable. Each section is equipped with the set of LED generating pulsating LED radiation as well as module which generates pulsating magnetic field in JPS System. Mobility of the section allows free positioning of the applicator over the applicated surface. Tissue penetration of the light is a few mm. APPLICATION delayed healing of superficial wound, ulceration and bed sore scars acne vulgaris herpes zoster first-degree burns May be applied in dermatology and aesthetic medicine.
Weight (two sections): Dimensions of one section Fixing Magnetic field induction (peak peak, at the middle of the section) Magnetic field frequency:
32
professional
Ref.
1081
Light
control unit
Magneti -Light c
control unit
medical room
TECHNICAL DATA Red radiation wavelength Infrared radiation wavelength Maximum red radiation power (in impulse) from two sections Maximum infrared radiation power (in impulse) from two sections Application area of one section Application area of two sections Safety class of radiation Type of connection 630 nm 855 nm 500 mW 3400 mW 280 cm2 560 cm2 3R 15-pin terminal for Light controler 12-pin terminal for MagneticLight controler 3,2 kg 24,5 cm x 18,2 cm x 11,5 cm at the LIGHT Stand 35 T 840 T 0,08 195 Hz (details on pg. 5.)
Weight (two sections) Dimensions of one section Fixing Magnetic field induction (peak peak, at the middle of the section) Magnetic field frequency
Skin diseases delayed healing of wound, ulceration and bedsore acne vulgaris herpes zoster May be applied in dermatology and aesthetic medicine.
professional
33
Ref.
Light
control unit
Magneti -Light c
Mobility of the section allows free positioning of the applicator over the surface of application. Tissue penetration of the light is up to several cm. APPLICATION Osteoarticular system diseases degenerative join disease pain syndromes of various aethiology overload (strain) and injuries of osteoarticular system bone fractures and delayed union of fractured bone chronic and subacute arthritis Soft tissue diseases soft tissue injuries syndromes due to strain of muscles and periarticular soft tissues periarthritis Neurological diseasesneuralgie neuralgia (intercostal neuralgia, trigeminal neuralgia, post herpetic neuralgia) sciatica diabetic neurophaty
control unit
TECHNICAL DATA Infrared radiation wavelength Maximum infrared radiation power (in impulse) from two sections Application area of one section Application area of two section Safety class of radiation Type of connection 855 nm 6800 mW 280 cm2 560 cm2 3R
medical room
15-pin terminal for Light Control Unit 12-pin terminal for MagneticLight Control Unit 3,2 kg 24,5 cm x 18,2 cm x 11,5 cm at the LIGHT Stand 35 T 840 T 0,08 195 Hz (details on pg. 5.)
Weight Dimensions of one section Fixing Magnetic field induction (peak peak, at the middle of the section) Magnetic field frequency
Applictor consists of two separate section. The panels are permanently linked by the cable. Each section is equipped with the set of LED generating pulsating LED radiation as well as module which generates pulsating magnetic field in JPS System.
Ref.
1082
Light
control unit
Magneti -Light c
control unit
Applicator is equipped with the set of LED generating pulsating LED radiation as well as module which generates pulsating magnetic field in JPS System. Tissue penetration of the light is up to several cm. APPLICATION The spectrum of application is analogue as IR Dual Panel Applicator (infrared) Ref. 1084 as above.
TECHNICAL DATA Infrared radiation wavelength Maximum infrared radiation power (in impulse) from three sections Application area of one section Application area of three sections Safety class of radiation Type of connection 855 nm 6000 mW 64 cm2 192 cm2 3R
medical room
15-pin terminal for Light Control Unit 12-pin terminal for MagneticLight controler 1,6 kg 30,0 cm x 13,0 cm x 11,5 cm at the LIGHT Stand 35 T 840 T 0,08 195 Hz (details on pg. 5.)
Weight Dimensions Fixing Magnetic field induction (peak peak, at the middle of the section) Magnetic field frequency
34
professional
Ref.
1083
LED Therapy
control unit
medical room
TECHNICAL DATA Red radiation wavelength Infrared radiation wavelength Maximum red radiation power (in impulse) from three sections Maximum infrared radiation power (in impulse) from three sections Application area of one section Application area of three sections Safety class of radiation Type of connection 630 nm 855 nm 450 mW 3000 mW 64 cm2 192 cm2 3R 15-pin terminal for Light controler 12-pin terminal for MagneticLight controler 1,6 kg 30,0 cm x 13,0 cm x 11,5 cm at the LIGHT Stand 35 T 840 T 0,08 195 Hz (details on pg. 5.)
Weight Dimensions Fixing Magnetic field induction (peak peak, atthe middle of the applicator)) Magnetic field frequency
professional
35
Ref.
1043
Applicator is designed for synchronous Pulsed Magnetic Field LED Therapy using red radiation. Tissue penetration of the light is a fewmm. The spectrum of usage is analogue as elliptic applicator (application of magnetic fields, pg. 16). Dueto the effect of red light it applies mainly in skin diseases. delayed healing of superficial wound, ulceration and bedsore acne vulgaris herpes zoster first-degree burns May be applied in dermatology and aesthetic medicine
control unit
medical room
TECHNICAL DATA Red radiation wavelength Maximum infrared radiation power (in impulse) Application area Magnetic field induction (peak peak) Magnetic field frequency Indicator of operating mode 634 nm 880 mW about 20 cm2 (a circle with a diameter about 5 cm) 50 T 1200 T 0,08 195 Hz (details on pg. 5.) flashing orange LED
36
professional
Ref.
1066
control unit
medical room
TECHNICAL DATA Red radiation wavelength Maximum infrared radiation power (in impulse) Application area Magnetic field induction (peak peak) Magnetic field frequency Indicator of operating mode 855 nm 1440 mW about 20 cm2 (a circle with a diameter about 5 cm) 50 T 1200 T 0,08 195 Hz (details on pg. 5.) flashing green LED
Neurological diseases neuralgia (intercostal neuralgia, trigeminal neuralgia, post herpetic neuralgia) sciatica diabetic neuropathy
Ref.
1044
control unit
medical room
TECHNICAL DATA Red radiation wavelength Infrared radiation wavelength Maximum red radiation power (in impulse) Maximum infrared radiation power (in impulse) Application area Magnetic field induction (peak peak) Magnetic field frequency Indicator of operating mode 634 nm 855 nm 440 mW 720 mW about 20 cm2 (a circle with a diameter about 5 cm) 50 T 1200 T 0,08 195 Hz (details on pg. 5.) flashing yellow LED
professional
37
Accesories
Ref.
1075
Ref.
1091
Service Set A
Spare fuses for the Classic Control Unit and applicators plugs.
Ref.
1092
Service Set B
Spare fuses for Clinic / Delux Control Unit.
Ref.
1074
Carrying Bag 3S
Ref.
1090
Cable ST
for coupling Viofor JPS Light / Viofor JPS Laser Control Units with Viofor JPS Clinic, Delux or Classic Control Units.
Ref.
1076
Carrying Bag 6S
Specially shaped for complete Home set. Facilitates the devices comfortable handling and transportation. Made of water-proof PCV.
Length
1m
38
professional
Certificates
Manufacturer Med & Life have established Quality Managment System certified to ISO 13485:2003 and ISO 9001:2008 Viofor JPS Systems for therapy and rehabilitation are in conformity with the Essential Requirements and provisions of Council Directive 93/42/EEC Medical Devices. Viofor JPS Systems are CE0120 marked.
39
Viofor JPS
Ref.
VETERINARY PRODUCTS
1101
The veterinary medical set includes: microprocessor Viofor JPS VET+ Control Unit (Ref. 1101) Battery Power BS-01 (Ref. 1103) Switching Power Supply (Ref. 1094) set of magnetic applicators dual-socket adaptor (Ref. 1106) eight-in-one socket adaptor (Ref. 1105) APPLICATIONS Animals suffer diseases, injuries and physiological conditions similar to humans. Indications included in this manual could be helpful in deciding the usefulness of the applicator in the animal. It is relevant that the veterinarian should carry out the assessment. Wellness, Prevention: accelerates the regeneration of the body after exercise promotes relaxation, slows heart rate, slows breathing and makes it deeper reduces the stress with the training, taming and sports competitions improves oxygenation of the body which allows better use of oxygen JPS VIOFOR VET+ PERFORMS THE FOLLOWING TYPES OF THERAPY: Pulsed Magnetic Field Stimulation in the JPS System the types of applications: Wellness and Therapy adapted to the size of the animal: large, medium, small adapted to the time of day: stimulant (Day), sedation (Night) application periods in weeks duration of treatment: 10min/12 min preset by manufacturer application duration multiplier: x1, x2 automatic change of magnetic field direction (polarization) the degree of intensity (level of magnetic induction) adapted to specific functional settings with possibility of adjusting it
TECHNICAL DATA Type of control unit Supply voltage: microprocessor 10-15 V DC, 1,6 A Power Supply MPU30-106 Batery Power BS-01 Plug-in adaptor to in-car lighter <5 VA 15 VA max. 15 V continuous running +10 +40 C / max 80% IP 40 (not waterproof) 32 cm x 27 cm x 10,5 cm 1,4 kg
Power consumption in OFF mode Max. power consumption podczas aplikacji Max output voltage on control unit socket Working mode Admissible working temperature/humidity Protection against water Maximum dimensions Weight
RECOMMENDATIONS FOR THE FOLLOWING DISEASES AND INJURIES: bruising and swelling spondylosis of the spine and osteoarticular system non-healing wounds rheumatic diseases and sores cracks and fractures circulatory disorders dislocations, sprains gastrointestinal mobility arthritis disorder injuries pain syndromes of different and inflammations origin of the tendons and tendon sheaths FUNCTIONAL USE OF APPLICATOR Viofor JPS VET+ is synonymous to Viofor JPS System Family+ medical device. Destined to perform operations on the entire body of an animal or selected parts of it. Viofor JPS VET+ is subject to the type of equipment which is destined to perform a therapy with pulsed magnetic field in veterinary clinics, professional animal husbandry and for individual users in the use of domestic animals. The battery supply of the device enables easy usage in a nonstationary conditions outside veterinary clinic.
40
Veterinary
JPS VIOFOR VET+ PERFORMS THE FUNCTIONS FOR: communication with the User via Menu programming and storage of functional settings identification of attached applicators application timing saving energy: turn off after two minutes of inactivity It works with specifically appointed application modules that is connected through G2 VET Adaptor or G8 VET Adaptor (Ref. 1106, Ref. 1105) and with single applicators for Pulsed Magnetic Field Stimulation: Large-Mat Applicator 3S and 6S (Ref. 1040, Ref. 1042), the Pad Applicator 3S and 6S (Ref. 1041, Ref. 1045), the Spot Applicator S (Ref. 1056), Elliptic Applicators (Ref. 1054, Ref. 1055).
Viofor JPS VET+ is equipped with: Graphic LCD display and function keyboard Switching Power Supply (Ref. 1094) can be supplied with Battery Power BS-01 (Ref. 1103) one socket for applicators for Pulsed Magnetic Field Stimulation.
LOCAL MODULE consists of 2 applicators - 6S pads connected to G2 VET Adaptor. Type of Application: Therapy GENERAL USE MODULE consists of 4 or 8 applicators 6S pads connected to the G8 VET Adaptor. Type of Application: Wellness, Therapy
Ref.
1045
VET+
control unit
TECHNICAL DATA Dimensions Magnetic field induction (peak peak) Magnetic field frequency 55 cm x 27 cm x 1,8 cm 22,5 T 540 T 0,08 195 Hz (details on pg. 5.)
Veterinary
41
Ref.
Switching Power Supply ensures correct operation of the control unit. It is also appropriate for charging Battery Power BS-01 Ref. 1103.
TECHNICAL DATA Supply parameters Output parameters safety class 100-240 V, 47-63 Hz, 0.9-0.34 A 15 V DC, 2 A I
Ref.
1103
TECHNICAL DATA AGM Battery AGM 12 V/3,4 Ah type (typ SB 3,4-12 or LC-R123R4PU) Power distributor (Ref. 1094) T 3,15 A
BS-01 Battery Power is intended to supply the Viofor JPS VET+ Control Unit. Allows the use of Viofor JPS VET System conditions where there is no possible connection to network power supply. This includes AGM battery with a capacity of 3.4 Ah and a battery charger. When loading, the battery works together with Power Supply (Ref. 1094).
Ref.
1105
G8 VET Adaptor
VET+
control unit
G8 VET adaptor permits the use of general application module that consists of 4 or 8 6S pads. In order to get the suitable conditions and parameters of application, all applicators (4 or 8) ought to be connected to all 4 or 8 sockets in your adaptor according to how is indicated.
Ref.
1106
G2 VET Adaptor
VET+
control unit
G2 VET adaptor enables the local application module that consists of two 6S pads. In order to get the correct conditions and parameters of the application, both pads ought to be connected to the ports in the adaptor.
42
Veterinary
Veterinary
43
Med & Life Sp. z o.o. Aleja Marii Dbrowskiej 45, 05-806 Komorw tel. +48 227591515, fax +48 227591519 e-mail: info@medandlife.com www.medandlife.com
Presentation anddistribution
VSEC-EN-VIII /11/2012
Project: Sebastian Rabczyski Agat Studio Graficzne Jerzy Burski www.agatstudio.waw.pl Photos: Robert Gauer, Marcin Gorazdowski and archives Med & Life Sp. z o.o.