Sie sind auf Seite 1von 18

WAUKESHA ENGINE

Power Ratings

WAUKESHA ENGINE
POWER RATINGS
G E N E R A L I N F O R M AT I O N

Waukesha Engine manufactures spark

Regional sales offices stand ready to serve

ignited gaseous fueled engines and

our customers, distributors, and OEMs.

Enginator systems for gas compression,


electric power generation, cogeneration
and mechanical drive applications
ranging in output from 100 to 4800 bhp
(75-3250 kWe).

Waukesha Engines many years of experience have shown that natural gas engines
can power or drive just about anything.
Waukesha offers a full line of heavy-duty,
gaseous-fueled engines that can be put to
work in a variety of markets including gas
compression, electric power generation,
cogeneration, and general mechanical drive
applications (pumps, air compressors,
chillers, blowers).

With decades of experience in engine tech-

Product Designations ..............................3


Application Guidelines for Altitude
and Temperature Adjustments To
Engine and Enginator Systems
For Natural Gas, Low Btu and
HD-5 Propane Fuels .............................15
Basic Formulas........................Page 3 flap
G A S C O M P R E S S I O N A P P L I C AT I O N S

With a global distribution network,


Waukesha services all major marketing
areas. Waukesha distributors are on call 24
hours a day, with the parts and service personnel to provide quick responsive solu-

Natural Gas Fueled Engines


Continuous Duty Applications...........4-5
M E C H A N I C A L D R I V E A P P L I C AT I O N S
Natural Gas Fueled Engines
Intermittent Duty Applications..........6-7
P O W E R G E N E R AT I O N
A P P L I C AT I O N S

tions to customers needs.

Waukesha Engine has found solutions to


almost any customer concern and need.
Our innovative product design improvements keep pace with customers everincreasing standards. From demands for

Remote Radiator Cooling......................8-9


Unit Mounted Radiator Cooling..............10
Heat Exchanger Cooling ........................11
Modulator Systems ...............................10
A LT E R N AT I V E F U E L A P P L I C AT I O N S
Low BTU Fueled Engines
Continuous Duty..........................12-13
HD-5 Propane Fueled Engines
Continuous Duty ...............................14

higher loads and speeds, to simple, longThis Power Ratings Bulletin supersedes all Power Ratings

term reliability, Waukesha understands

Bulletins prior to 12/01.


Waukesha, Enginator, VHP, VGF, ATGL, VSG, Modulator,

those needs and continues to design,

WKI, Engenius and ESM are trademarks/registered trademarks of Waukesha Engine, Dresser, Inc.

build, and service the best engines in the


marketplace.

nology together with excellent engineering


skills, Waukesha has found cost-effective
solutions for many customer needs.
Customers recognize that Waukesha

Waukesha Engine Family Ranges


0

1000

2000

3000

4000

5000

BHP

BHP

BHP

BHP

BHP

BHP

engines can power all types of equipment

1565 - 4830

and do it more cost effectively.

ATGL
Waukesha manufactures engines in the
United States (Waukesha, Wisconsin) and
in Europe (Appingedam, The Netherlands).
Both manufacturing facilities are certified
by the worlds leading registrar, Lloyds

256 - 2560
VHP
250 - 1175
VGF
90 - 260
VSG

Register Quality Assurance (LQRA), to the


ISO 9001 Quality Management Standard.

7,040 in3 displacement

VHP L 7042 GL
Product Designations

12 Cylinder

Turbocharged,
intercooled, lean burn

Engine Series
Waukesha manufactures four engine families the ATGL, VHP, VGF, and VSG.

Prefix Designations
The prefix attached to an engine model indicates the number of cylinders (except ATGL
which states actual number): P = 16, L = 12, H = 8, F = 6.
VHP L7042GL engine is a 12 cylinder engine
VGF P48 GL is a 16 cylinder engine
16V-AT27GL is a 16 cylinder engine

Numeric Designations

VHP Engine Series Models


P9390G, GSI, GL;
L7044GSI;
L7042G, GSI, GL, GLD;
L5774LT
L5794GSI, LT;
L5790GSI, GL, GLD;
F3524GSI;
F3521GSI, GL, GLD;
F2895GSI, GL, GLD

The numeric designation in each engine model name indicates the displacement of the
engine model in either English units of cubic inches or metric units of liters.
The VHP series show a displacement in cubic inches. For example: the VHP L7042GL
indicates a displacement of 7,040 in3.
The VGF and VSG series show a displacement in liters. For example: the VGF P48GL
indicates a displacement of 48 liters.

48 liters displacement

VGF P 48 GLD
16 Cylinder

Turbocharged,
intercooled, lean burn,
draw-thru

The VSG F11G indicates a displacement of 11 liters.


The ATGL series is designated by a numeric indicative of the bore size in millimeters.
For example: the 27 of the 16V-AT27GL indicates a 275 millimeter bore.

P48GL, GLD, GSID;


L36GL, GLD, GSID;
H24GL, GLD, GSID;
F18GL, GLD, GSID

Suffix Designations
G
GSI
GSID
LT
LTD
GL
GLD

=
=
=
=
=
=
=

VGF Engine Series Models

Naturally aspirated
Turbocharged, intercooled
Turbocharged, intercooled, draw thru
Lean combustion turbulence
Lean combustion turbulence, draw-thru
Turbocharged, intercooled, lean burn
Turbocharged, intercooled, lean burn, draw-thru

11 liters displacement

VSG F11G

Other Waukesha Engine Products

Naturally
aspirated

6 Cylinder

Waukesha Power Systems Enginator Series

VSG Engine Series Models

The Enginator is a Waukesha Engine registered trademark of an engine generator set


packaged by Waukesha Power Systems. WPS also designs and assembles Engomatic
panels (switchgear control systems).

F11G, GSI, GSID

Waukesha Power Systems Modulator Series

275 millimeter bore

Waukeshas Modulator is a self-contained power plant designed to provide on-site power


generation anywhere power is needed. The preassembled unit is powered by Waukeshas
reliable VGF or VHP Series Enginators.

16 Cylinder

Custom Engine Controls (CEC) Series


AFM
DSM
IM
TCM
KDM

=
=
=
=
=

Air/Fuel Module
Detonation Sensing Module
Ignition Module
Turbocharger Control Module
Knock Detection Module

Turbocharged,
intercooled,
lean burn

ATGL Engine Series Models:


16V-AT27GL
12V-AT27GL
8L-AT27GL

Waukesha Engenius Series


ESM

16 V-AT 27 GL

= Engine System Manager


3

BASIC FORMULAS

English
F = (Degrees C x 1.8) + 32
Torque lb-ft =
BMEP (psi) =

5250 x BHP
rpm
150.8 x Torque (lb-ft)
Displacement (cubic inches)

BHP = BMEP x Displacement (cubic inches) x rpm


792,000

Metric
(Degrees F-32)
1.8
kWb x 9550
Torque (Nm) =
rpm
C =

BMEP (bar) =

kWb =

kWb x 1200
Displacement (liters) x rpm

BMEP (bar) x Displacement (liters) x rpm


1200

Displacement

D2

Displacement =

x S x C = 0.7854 D2SC

Where: Displacement = cubic inch.


D = Bore Dia. in.
C = No. of cyl.
S = Stroke in.
p = 3.1416

Piston Speed
Piston Speed = P =

NS Where: P = Ft. per Min.


N = rpm
6
S = Stroke in

Formulas To Determine kW, KVA,


Reactive KVA, BHP And Amperes
(for three phase AC)
KVA =

1.73 x Volts x Amps


1000

kW = KVA x PF
kWe = kWB x Eff
1.73 x Volts x Amps x PF
.746 x 1000 x Eff
kW
BHP =
.746 x Eff
BHP x .746 x 1000 x Eff
AMPS =
1.73 x Volts x PF
kW x 1000
AMPS =
1.73 x Volts x PF
KVA x 1000
AMPS =
1.73 x Volts

BHP =

Reactive KVA = KVA x

1 - PF2

BORE & STROKE/


DISPLACEMENT CHART

Model

Displacement

Bore/Stroke

ATGL VEE-16
16V-AT27GL
English
Metric

17,398 in3
(285 L)

10.83 x 11.81
(275 x 300 mm)

ATGL VEE-12
12V-AT27GL
English
Metric

13,048 in3
(214 L)

10.83 x 11.81
(275 x 300 mm)

ATGL IN-LINE 8
8L-AT27GL
English
Metric

8699 in3
(143 L)

10.83 x 11.81
(275 x 300 mm)

VHP VEE-16
P9390
English
Metric

9388 in3
(154 L)

9.375 x 8.5
(238 x 216 mm)

VHP VEE-12
L7042/L7044
English
Metric

7040 in3
(116 L)

9.375 x 8.5
(238 x 216 mm)

VHP VEE-12
L5790/L5794/
L5774
English
Metric

5788 in3
(95 L)

8.5 x 8.5
(216 x 216 mm)

VHP IN-LINE 6
F3521/F3524
English
Metric

3520 in3
(58 L)

9.375 x 8.5
(238 x 216 mm)

VHP IN-LINE 6
F2895
English
Metric

2894 in3
(47 L)

8.5 x 8.5
(216 x 216 mm)

VGF VEE-16
P48
English
Metric

2924 in3
(48 L)

5.98 x 6.5
(152 x 165 mm)

VGF VEE-12
L36
English
Metric

2193 in3
(36 L)

5.98 x 6.5
(152 x 165 mm)

VGF IN-LINE 8
H24
English
Metric

1462 in3
(24 L)

5.98 x 6.5
(152 x 165 mm)

VGF IN-LINE 6
F18
English
Metric

1096 in3
(18 L)

5.98 x 6.5
(152 x 165 mm)

VSG IN-LINE 6
F11
English
Metric

673 in3
(11 L)

5.5 x 5.71
(127 x 145 mm)

NATURAL GAS FUELED


CONTINUOUS DUTY

Engine Family

Model

ATGL

16V-AT27GL
16V-AT27GL
12V-AT27GL
12V-AT27GL
8L-AT27GL
8L-AT27GL

VHP

P9390GSI
P9390GSI
P9390GL
P9390GL
P9390G
P9390G
L7044GSI
L7042GSI
L7042GSI
L7042GL
L7042GL
L7042G
L7042G

Gas

Compression

L5794GSI
L5790GSI
L5790GSI
L5794LT
L5794LT
L5774LT
L5790GL
L5790GL
F3524GSI
F3521GSI
F3521GSI
F3521GL
F3521GL
F2895GSI
F2895GSI
F2895GL
F2895GL

VGF

These power ratings require pricebook option


Code 1100 (176 BMEP) and DSM. They are
available continuously when applied per
WKI Power and Timing Curve S7079-14. It
is permissible to operate at up to 5% overload
for two hours in each 24 hour period.

Ratings with low compression ratio (8.7:1)


pistons, also apply to HD-5 propane fueled
engines.

Low speed turbocharger required for operation at 1000 - 1400 rpm on Inline engines for
from 1100 - 1600 rpm on Vee engines.

P48GSID
P48GL/GLD
P48GL1/GLD1
L36GSID
L36GL/GLD
L36GL1/GLD1
H24GSID
H24GL/GLD
H24GL2
H24GL1/GLD1
F18GSID
F18GL/GLD
F18GL2
F18GL1/GLD1

VSG
4

F11GSI/GSID
F11GSI/GSID
F11G

Continuous Duty
I.C. Water
Temp.
(Tcra)

C.R.
(compression
ratio)

F C

800 rpm

900 rpm

1000 rpm

1200 rpm

1400 rpm

1500 rpm

1600 rpm

bhp kWb

bhp kWb

bhp kWb

bhp kWb

bhp kWb

bhp kWb

bhp kWb

1800 rpm
bhp kWb

90
130
90
130
90
130

32
54
32
54
32
54

9:1
9:1
9:1
9:1
9:1
9:1

3600
3600
2640
2508
1760
1670

2686
2686
1967
1871
1312
1246

4050
4050
2970
2820
1980
1880

3020
3020
2216
2104
1477
1405

4500
4500
3295
3130
2200
2090

3356
3356
2458
2335
1641
1560

85
130
85
130

29
54
29
54

8:1
8:1
10.5:1
10.5:1
10:1
8:1

1375
1314
1375
1314
976
900

1025
980
1025
980
738
671

1547
1478
1547
1478
1090
998

1154
1102
1154
1102
813
744

1719
1642
1719
1642
1194
1081

1282
1224
1282
1224
890
806

2063
1970
2063
1970
1366
1216

1538
1469
1538
1469
1019
907

130
85
130
85
130

54
29
54
29
54

8:1
8:1
8:1
10.5:1
10.5:1
10:1
8:1

1120
1031
985
1031
985
732
675

836
769
735
769
735
546
503

1260
1160
1108
1160
1108
818
748

940
865
826
865
826
610
558

1400
1289
1232
1289
1232
896
810

1044
961
919
961
919
668
604

1680
1547
1478
1547
1478
1024
912

1253
1154
1102
1154
1102
764
680

130
85
130
85
130
130
85
130

54
29
54
29
54
54
29
54

8.2:1
8.2:1
8.2:1
10.2:1
10.2:1
10.2:1
10:1
10:1

920
848
810

848
810

686
632
604

632
604

1035
954
911

954
911

772
711
679

711
679

1150
1060
1013
1265
1205
1040
1060
1013

858
790
755
944
899
776
790
755

1380
1272
1215
1515
1445
1250
1272
1215

1029
949
906
1130
1078
933
949
906

130
85
130
85
130

54
29
54
29
54

8:1
8:1
8:1
10.5:1
10.5:1

560
516
492
516
492

418
385
367
385
367

630
580
554
580
554

470
433
413
433
413

700
644
615
644
615

522
480
459
480
459

840
773
738
773
738

627
577
550
577
550

85
130
85
130

29
54
29
54

8.2:1
8.2:1
10:1
10:1

424
405
424
405

316
302
316
302

477
455
477
455

356
339
356
339

530
506
530
506

395
377
395
377

636
607
636
607

474
453
474
453

130 54
130 54
130 54

8.7:1
11:1
11:1


7103 5303

830 620
8302 6202
9102 6802

885 660
885 660
975 730

945 705
945 705
1040 775

1065 800
1065 800
1175 880

130 54
130 54
130 54

8.7:1
11:1
11:1


5303 4003

620 460
6202 4602
6852 5102

670 500
670 500
735 550

710 530
710 530
780 580

800 600
800 600
880 660

130
130
130
130

54
54
54
54

8.7:1
11:1
8.7:1
11:1

3553

2653

415
4152
4152
4552

310
3102
3102
3402

445
445
445
490

330
330
330
365

475
475
475
520

355
355
355
390

530
530
530
585

400
400
400
440

130
130
130
130

54
54
54
54

8.7:1
11:1
8.7:1
11:1

2653

2203

310
3102
3102
3402

230
2302
2302
2552

335
335
335
365

250
250
250
275

355
355
355
390

265
265
265
290

400
400
400
440

300
300
300
330

85 29
130 54

10:1
10:1
10:1

166 124
166 124
90 67

194 145
194 145
105 78

208 155
208 155
112 84

222 165
222 165
120 90

250 186
250 186
135 101

Iso Standard Power (Continuous Power Rating): The highest load and speed which can be applied 24 hours per day, seven days per week, 365 days per year except for normal maintenance. It is permissible to operate
the engine at up to 10% overload or the maximum load indicated by the intermittent rating, whichever is lower, for two hours in every 24 hour period.

NATURAL GAS FUELED


INTERMITTENT DUTY

Engine Family

Model

ATGL

16V-AT27GL
16V-AT27GL
12V-AT27GL
12V-AT27GL
8L-AT27GL
8L-AT27GL

VHP

P9390GSI
P9390GSI
P9390GL
P9390GL
P9390G
P9390G

Engine available with draw-thru carburetion


with the same ratings.
1

2
Refer to pages 12 and 13 for VHP GL
engines equipped with draw-thru carburetion
(low fuel pressure system).

Mechanical

Dr ves

L7044GSI
L7042GSI1
L7042GSI1
L7042GL2
L7042GL2
L7042G
L7042G
L5794GSI
L5790GSI1
L5790GSI1
L5794LT2
L5794LT2
L5790GL2
L5790GL2
F3524GSI
F3521GSI1
F3521GSI1
F3521GL2
F3521GL2
F2895GSI1
F2895GSI1
F2895GL2
F2895GL2

VGF

Low speed turbocharger required for operation at 1000 - 1400 rpm on Inline engines or
from 1100 - 1600 rpm on Vee engines.

P48GSID
P48GL/GLD
L36GSID
L36GL/GLD
H24GSID
H24GL/GLD
F18GSID
F18GL/GLD

VSG

F11GSI/GSID
F11GSI/GSID
F11G

Intermittent Duty
I.C. Water
Temp.
(Tcra)

C.R.
(compression
ratio)

800 rpm
bhp kWb

F C
90
130
90
130
90
130

32
54
32
54
32
54

9:1
9:1
9:1
9:1
9:1
9:1

85
130
85
130

29
54
29
54

8:1
8:1
10.5:1
10.5:1
10:1
8:1

130
85
130
85
130

54
29
54
29
54

130
85
130
85
130
85
130

900 rpm

1000 rpm

1200 rpm

1400 rpm

1500 rpm

1600 rpm

1800 rpm

bhp kWb

bhp kWb

bhp kWb

bhp kWb

bhp kWb

bhp kWb

bhp kWb

4350
4130
3267
3102
2178
2068

3244
3080
2437
2314
1625
1546

4830
4590
3625
3443
2420
2299

3602
3423
2704
2569
1809
1716

1707
1631
1513
1445
1098
1013

1273
1216
1128
1078
819
755

1920
1835
1702
1626
1227
1122

1432
1368
1269
1213
915
837

2134
2039
1891
1806
1344
1216

1591
1520
1410
1347
1002
907

2560
2447
2270
2167
1536
1368

1909
1825
1693
1616
1145
1020

8:1
8:1
8:1
10.5:1
10.5:1
10:1
8:1

1120
1280
1223
1134
1084
824
760

836
954
912
846
808
614
567

1260
1440
1376
1276
1219
920
842

940
1074
1026
952
909
686
628

1400
1600
1528
1418
1355
1008
912

1044
1193
1139
1057
1010
752
680

1680
1920
1834
1702
1626
1152
1026

1253
1432
1368
1269
1213
859
765

54
29
54
29
54
29
54

8.2:1
8.2:1
8.2:1
10.2:1
10.2:1
10:1
10:1

920
1052
1005

933
891

686
784
749

696
664

1035
1184
1131

1049
1002

772
883
843

782
747

1150
1315
1257
1390
1315
1166
1114

858
981
937
1037
981
869
831

1380
1579
1508
1665
1580
1399
1337

1029
1177
1125
1242
1178
1043
997

130
85
130
85
130

54
29
54
29
54

8:1
8:1
8:1
10.5:1
10.5:1

560
640
611
568
541

418
477
456
424
403

630
720
688
638
598

470
537
513
476
446

700
800
764
708
677

522
597
570
528
505

840
960
917
850
812

627
716
684
634
606

85
130
85
130

29
54
29
54

8.2:1
8.2:1
10:1
10:1

526
503
466
446

392
375
347
333

592
566
525
501

441
422
391
374

658
628
583
557

491
468
435
415

789
754
700
668

588
562
522
498

130 54
130 54

8.7:1
11:1


7853 5853

910 680
9103 6803

975 730
975 730

1040 775
1040 775

1175 880
1175 880

130 54
130 54

8.7:1
11:1


5853 4403

685 510
6853 5103

735 550
735 550

780 580
780 580

880 660
880 660

130 54
130 54

8.7:1
11:1


3953 2903

455 340
4553 3403

490 365
490 365

520 390
520 390

585 440
585 440

130 54
130 54

8.7:1
11:1


2953 2203

340 255
3403 2553

365 275
365 275

390 290
390 290

440 330
440 330

85 29
130 54

10:1
10:1
10:1

173 129
166 124
100 75

202 151
194 145
117 87

217 162
208 155
125 93

231 172
222 165
133 99

260 194
250 186
150 112

Intermittent Power Rating: The highest load and speed that can be applied in variable speed mechanical system applications only. Operation at this rating is limited to a maximum of 3500 hours per year.
NOTE: For continuous duty power ratings for mechanical drives, please see pages 4 and 5.

E N G I N AT O R
R E M O T E R A D I AT O R C O O L I N G

130F 54C (Tcra)


Intercooler Water Temperature

Engine Family

Model

ATGL

16V-AT27GL
12V-AT27GL
8L-AT27GL

VHP

VHP9500GSI
VHP9500GL
VHP7104GSI
VHP7104GSID
VHP7100GSI
VHP7100GSID
VHP7100GL
VHP5904LT
VHP5904LTD
VHP9500G
VHP5904GSI
VHP5904GSID
VHP5900GSI
VHP5900GSID
VHP5900GL
VHP7100G
VHP3604GSI
VHP3604GSID
VHP3600GSI
VHP3600GSID
VHP3600GL
VHP2900GSI
VHP2900GSID
VHP2900GL

10% overload not available on these ratings.


Contact factory for allowable overload ratings.
Output based on .8 Power Factor.

2
3

5% overload allowed.
No overload allowed.

Power

Generation
VGF

VGF48GL
VGF48GLD
VGF48GSID
VGF36GL
VGF36GLD
VGF36GSID
VGF24GL
VGF24GLD
VGF24GSID
VGF18GL
VGF18GLD
VGF18GSID

VSG

VS11GSI
VS11GSID
VS11G

FOR CONTINUOUS ONLY - These power


ratings require pricebook option Code 1100
and DSM. They are available continuously
when applied per WKI Power and Timing
Curve S7079-14. It is permissible to operate
at up to 5% overload for two hours in each
24 hour period.

Remote Radiator Cooling

(kWe)

60Hz
Continuous

50Hz

Peak Shave*

Standby

Continuous

Standby

1800
rpm

1200
rpm

900
rpm

1800
rpm

1200
rpm

900
rpm

1800
rpm

1200
rpm

900
rpm

1500
rpm

1000
rpm

1500
rpm

1000
rpm

2960 1
2000
1330

2960
2140
1425

2960
2200
1460

3250 1
2220
1480

3250
2440
1630

1400
1400
1200
1200
1050
1050
1050
1025
1025
975
980
980
865
865
865
725
600
600
525
525
525
425
425
425

1500
1490
1250
1250
1180
1180
1100
1080
1025
975
1035
1035
970
970
910
725
630
630
585
585
550
485
485
455

1750
1540
1300
1300
1300
1300
1155
1125
1025
1075
1060
1060
1060
1060
955
810
650
650
650
650
580
525
525
470

1175
1175
1100 3
1100 3
875
875
875
900 2
900
850
900 3
900 3
720
720
720
635
540 3
540 3
435
435
435
350
350
350

1450
1295
1100
1100
1075
1075
965
940
900
950
900
900
880
880
795
710
540
540
535
535
480
440
440
385

830 4
830 4
750
620 4
620 4
560
415 4
415 4
375
310 4
310 4
280

830
830
750
620
620
560
415
415
375
310
310
280

860
860
825
645
645
620
425
425
410
315
315
310

685 4
685 4
625
515 4
515 4
475
340 4
340 4
310
250 4
250 4
230

715
715
685
535
535
515
355
355
340
260
260
255

150
150
90

150
150
90

180
180
100

125
125
75

150
150
80

Generator Standby Power Rating (kWe): This rating applies to those systems used as a secondary source of electrical power. This rating is the output the system will produce continuously (no overload), 24 hours per
day for the duration of the prime power source outage.
*Peak Shave: These ratings are based on 3400 hours per year at ISO Standard reference conditions. Peak shaving and standby ratings may reduce lifecycle intervals.

ENGINATOR
UNIT MOUNTED
RADIATOR COOLING
130F 54C (Tcra)
I.C. Water Temp.

60Hz
Continuous (kWe)

50Hz
Standby (kWe)

Continuous (kWe)

Standby (kWe)

1800
rpm

1200
rpm

1800
rpm

1200
rpm

1500
rpm

1000
rpm

1500
rpm

1000
rpm

VHP7104GSI/GSID
VHP7100GSI/GSID
VHP7100GL
VHP5904LT
VHP5904LTD2
VHP9500G
VHP5904GSI/GSID
VHP5900GSI/GSID
VHP5900GL
VHP7100G
VHP3604GSI/GSID
VHP3600GSI/GSID
VHP3600GL
VHP2900GSI/GSID
VHP2900GL

1150
1000
1025
990
990
950
940
835
835
700
560
500
500
400
400

1260
1260
1130
1090
1090
1065
1030
1050
920
800
615
625
550
505
450

1050 2
840
845
825
825
820
860 2
690
690
610
500 2
410
410
335
335

1050
1050
930
900
825
930
860
860
760
685
500
515
450
415
370

VGF

VGF48GL
VGF48GLD
VGF48GSID
VGF36GL
VGF36GLD
VGF36GSID
VGF24GL
VGF24GLD
VGF24GSID
VGF18GL
VGF18GLD
VGF18GSID

808 3
808 3
730 3
590 3
590 3
530 3
388 3
388 3
350 3
294 3
294 3
265 3

825
825
800
625
625
600
405
405
400
300
300
300

670 3
670 3
610 3
500 3
500 3
450 3
330 3
330 3
300 3
245 3
245 3
220 3

700
700
650
525
525
490
350
350
325
250
250
240

VSG

VS11GSI
VS11GSID
VS11G

140
140
80

175
175
90

120
120
65

145
145
75

Engine Family

Model

VHP
1

5% overload allowed.

No overload.

3
GL AND GLD MODELS
ONLY, with high compression
ratio (11:1) pistons. These
power ratings require pricebook option Code 1100 and
DSM. They are available
continuously when applied
per WKI Power and Timing
Curve S7079-14. It is permissible to operate at up to
5% overload for two hours in
each 24 hour period.

For Power Unit ratings, please contact the Waukesha Sales Engineering Department.

M O D U L AT O R S Y S T E M S
CONTINUOUS DUTY

Waukeshas Modulators are self-contained power plants with radiator cooled Enginators individually packaged in
ISO shipping containers.

50Hz

60Hz
1800
rpm

1200
rpm

1500
rpm

1000
rpm

VGF18GL1/GLD1
VGF18GSID
VGF24GL1/GLD1
VGF24GSID
VGF36GL1/GLD1
VGF36GSID
VGF48GL1/GLD1
VGF48GSID

290
265
380
340
575
515
750
680

240
220
315
285
475
430
625
565

VHP5904GSID
VHP5904LTD

920
965

840
840

Engine Family

Model

VGF

Ratings for GL/GLD engines


are based on engine code
1100 176 BMEP with 5%
overload capability. Requires
pipeline quality natural gas
with a minimum SLHV of
850 Btu/FT3, 85 WKI per
S7079-14.
1

VHP

10

ENGINATOR
HEAT EXCHANGER
COOLING

60Hz
Continuous (kWe)

50Hz
Standby (kWe)

Continuous (kWe)

Standby (kWe)

1800
rpm

1200
rpm

900
rpm

1800
rpm

1200
rpm

900
rpm

1500
rpm

1000
rpm

1500
rpm

1000
rpm

Engine Family

Model

ATGL

16V-AT27GL
12V-AT27GL
8L-AT27GL

29601
2100
1400

3100
2310
1540

3250 1
2340
1550

3430
2570
1710

VHP

VHP9500GSI
VHP9500GL
VHP7104GSI/GSID4
VHP7100GSI/GSID
VHP7100GL
VHP5904LT
VHP5904LTD5
VHP5904GSI/GSID4
VHP9500G
VHP5900GSI/GSID
VHP5900GL
VHP7100G
VHP3604GSI/GSID
VHP3600GSI/GSID
VHP3600GL
VHP2900GSI/GSID
VHP2900GL

1475
1475
1200
1100
1100
1075
1075
980
975
900
900
725
600
550
550
450
450

1825
1625
1310
1350
1210
1175
1075
1080
1075
1125
990
810
650
675
600
550
495

1225
1225
1100 5
920
920
900 3
900
900 5
850
750
750
635
540 5
450
450
375
375

1520
1350
1100
1125
1015
975
900
900
950
925
825
710
540
560
495
450
415

VGF48GL
VGF48GLD
VGF48GSID
VGF36GL
VGF36GLD
VGF36GSID
VGF24GL
VGF24GLD
VGF24GSID
VGF18GL
VGF18GLD
VGF18GSID

830 7
830 7
750 7
615 7
615 7
560 7
406 7
406 7
375 7
305 7
305 7
280 7

860
860
825
645
645
620
425
425
410
315
315
310

685 7
685 7
625 7
515 7
515 7
475 7
340 7
340 7
310 7
250 7
250 7
240 7

720
720
690
535
535
515
360
360
350
260
260
255

VS11GSI
VS11GSID
VS11G

160
160
90

180
180
100

135
135
75

150
150
80

90F (32C) I.C. Water Temp.


1
10% overload not available

85F (29C) I.C. Water Temp.


3

5% overload allowed

130F (54C) Intercooler


Water Temperature

No overload

VGF

130F (54C) I.C. Water


Temp.
These power ratings require
pricebook option Code 1100
and DSM. They are available
continuously when applied
per WKI Power and Timing
Curve S7079-14. It is permissible to operate at up to
5% overload for two hours
in each 24 hour period.

VSG

85F (29C) I.C. Water Temp.

Waukesha
Modulator

VHP7104 Enginator

11

VGF L36 Enginator


with unit mounted radiator

LOW BTU FUELED


CONTINUOUS DUTY

Engine Family

Model

VHP

P9390GSI
P9390GSI
P9390GL
P9390GL
P9390G1
P9390G1

VHP Naturally Aspirated Engine ratings


based on 600 Btu/ft3 (23.58 MJ/m3), saturated low heat (net calorific value).
1

Draw-thru carburetion

L7042GSI
L7042GSI
L7042GL2
L7042GL2
L7042GL
L7042GL
L7042G1
L7042G1
L5794LT2
L5794LT2
L5790GSI
L5790GSI
L5790GL2
L5790GL2
L5790GL
L5790GL

Alternative

F3521GSI2
F3521GSI2
F3521GL2
F3521GL2
F3521GL
F3521GL

Fuels
Bio-Gas
Landfill
Digester

12

F2895GSI2
F2895GSI2
F2895GL2
F2895GL2
F2895GL
F2895GL

VGF

P48GLD4

Engine operation using 400 - 500 Btu/ft3


(15.7 - 19.7 MJ/m3) fuel requires 175F
(80C) ICW.

H24GLD4

VSG

F11GSI/GSID
F11GSI/GSID
F11G

Low speed turbo required for VGF operation


at 1200 - 1400 rpm.

L36GLD4

F18GLD4

Continuous Duty
I.C. Water
Temp.
(Tcra)

C.R.

900
rpm

(compression
ratio)

F C

1000
rpm

1200
rpm

1500
rpm

1800
rpm

bhp

kWb

kWe*

bhp

kWb

kWe*

bhp

kWb

kWe*

bhp

kWb

kWe*

bhp

kWb

kWe*

85
130
85
130

29
54
29
54

8:1
8:1
10.5:1
10.5:1
10:1
8:1

1547
1478
1547
1478
932
853

1154
1102
1154
1102
695
636

1096
1047
1096
1047
660
604

1719
1642
1719
1642
1021
924

1282
1224
1282
1224
761
689

1218
1163
1218
1163
723
655

2063
1970
2063
1970
1168
1040

1538
1469
1538
1469
871
776

1461
1400
1461
1400
827
737

85
130
85
130
85
130

29
54
29
54
29
54

8:1
8:1
10.5:1
10.5:1
10.5:1
10.5:1
10:1
8:1

1160
1108

1160
1108
699
640

865
826

865
826
521
477

822
785

822
785
495
453

1289
1232
1289
1232
1289
1232
766
693

961
919
961
919
961
919
571
517

913
873
913
873
913
873
542
491

1547
1478
1280
1280
1547
1478
876
780

1154
1102
955
955
1154
1102
653
582

1096
1050
907
907
1096
1050
620
553

85
130
85
130
85
130
85
130

29
54
29
54
29
54
29
54

10.2:1
10.2:1
8.2:1
8.2:1
10:1
10:1
10:1
10:1

954
911

954
911

711
679

711
679

675
645

675
645

1260
1205
1060
1013
1060
1012
1060
1013

940
899
790
755
790
755
790
755

893
854
751
717
751
717
751
717

1515
1445
1272
1215
1052
1052
1272
1215

1130
1078
949
906
785
785
949
906

1074
1025
902
865
746
746
902
861

85
130
85
130
85
130

29
54
29
54
29
54

8:1
8:1
10.5:1
10.5:1
10.5:1
10.5:1

580
554
580
554
580
554

433
413
433
413
433
413

411
392
411
392
411
392

644
615
644
615
644
615

480
459
480
459
480
459

456
436
456
436
456
436

773
738
640
640
773
738

576
550
477
477
577
551

547
525

548
523

85
130
85
130
85
130

29
54
29
54
29
54

8.2:1
8.2:1
10:1
10:1
10:1
10:1

477
455
477
455
477
455

356
339
356
339
356
339

338
322
338
322
338
322

530
506
530
506
530
506

395
377
395
377
395
377

375
358
375
358
375
358

636
607
526
526
636
607

474
453
392
392
474
453

450
425

450
430

130 54

11:1

710 3

530 3

500

885

660

625

1060

800

750

130 54

11:1

530

400

375

670

500

475

800

600

560

130 54

11:1

355 3

265 3

250

445

330

310

530

400

375

130 54

11:1

265 3

200 3

185

335

250

230

400

300

280

85 29
130 54

10:1
10:1
10:1

166
166
84

124
124
63

115
115
59

208
208
106

155
155
79

144
144
73

250
250
127

186
186
95

173
150
88

NOTE: Low Btu (calorific value) fueled engines operate on fuel with 400 Btu/ft3 (15.7 MJ//m3), saturated low heat (net calorific value), and are equipped with special low Btu (calorific value) fuel system.
NOTE: VGF GLD - Gas lean combustion with draw-thru carburetion. Minimum regulated gas supply pressure is 8" H2O (12.44 mbar)
NOTE: VSG G - Ratings based on 600 Btu/ft3 (23.58 MJ/m3), saturated low heat (net calorific value).
NOTE: For complete information regarding operation on Low Btu Fuel, see the S3955 series (latest version) Technical Data Sheets. See Price Book for proper hardware requirements.
NOTE: For low Btu Intermittent Duty application ratings, consult the Waukesha Engine Sales Engineering Department.
NOTE: Generator efficiencies are typical values. Please consult with your packager.
*kWe ratings are based on Waukesha Power Systems generator efficiencies.

13

HD-5 PROPANE
FUELED ENGINES

Continuous Duty
I.C. Water
Temp.
(Tcra)

Model

VHP

No overload allowed.

VGF

Requires KDM on F18


and H24 GL/ GLD/GSID
models or DSM on L36
and P48 GL/GLD/GSID
models.

VSG

C.R.
(compression
ratio)

F C

900 rpm

1000 rpm

1200 rpm

1500 rpm

1800 rpm

bhp kWb

bhp kWb

bhp kWb

bhp kWb

bhp kWb

P9390GSI
P9390GSI
P9390GL
P9390GL
P9390G

85
130
85
130

29
54
29
54

8:1
8:1
10.5:1
10.5:1
8:1

1237
1162
1237
1184
1066

923
867
923
883
795

1327
1244
1374
1315
1164

990
928
1025
981
868

1479
1379
1649
1578
1303

1103
1029
1230
1177
972

L7044GSI
L7042GSI
L7042GSI
L7042GL
L7042GL
L7042G

130
85
130
85
130

54
29
54
29
54

8:1
8:1
8:1
10.5:1
10.5:1
8:1

944
928
871
928
888
800

704
692
650
692
662
597

1049
996
933
1031
987
873

782
743
696
769
736
651

1259
1109
1035
1237
1184
978

939
827
772
923
883
730

L5794GSI
L5790GSI
L5790GSI
L5790GL
L5790GL

130
85
130
85
130

54
29
54
29
54

8.2:1
8.2:1
8.2:1
10:1
10:1

868
763
717
763
729

647
569
535
569
544

965
819
767
847
811

719
611
572
632
605

1158
912
851
1016
973

863
680
635
758
726

F3524GSI
F3521GSI
F3521GSI
F3521GL
F3521GL

130
85
130
85
130

54
29
54
29
54

10.5:1
8:1
8:1
10.5:1
10.5:1

472
464
436
464
444

352
346
325
346
331

524
497
466
516
493

391
371
348
385
368

629
555
517
619
592

469
414
386
462
442

F2895GSI
F2895GSI
F2895GL
F2895GL

85
130
85
130

29
54
29
54

8.2:1
8.2:1
10:1
10:1

381
358
381
365

284
267
285
272

409
383
424
406

305
286
316
303

456
425
509
487

340
317
379
363

P48GSID
P48GL/GLD

130 54
130 54

8.7:1
11:1


402 2 300 2

712 2 528 2
496 2 370 2

848 640
604 450

L36GSID
L36GL/GLD

130 54
130 54

8.7:1
11:1


300 2 224 2

528 2 400 2
376 2 280 2

640 512
442 330

H24GSID
H24GL/GLD

130 54
130 54

8.7:1
11:1


201 2 150 2

356 2 264 2
248 2 185 2

424 320
302 225

F18GSID
F18GL/GLD

130 54
130 54

8.7:1
11:1


150 2 112 2

264 2 200 2
188 2 140 2

320 256
221 165

F11GSI
F11GSI
F11G

85 29
130 54

10:1
10:1
10:1

102 76
102 76
101 75

127 95
127 95
123 92

153 114
153 114
150 112

NOTE: These engines use propane as a secondary fuel: VHPGL Series, VHPGSI Series, VSGGSI Series.

14

Adjustments To Engine And Enginator Systems For High Altitude And High Temperature1 For Natural Gas, Low BTU
and HD-5 Propane Fuels
Turbocharged and Intercooled
All VSG
VSG F11 (Generator Standby
Power Rating)
VSG GSI6
Propane
All VGF GL/GLD/GSID

VGF GL (Generator Standby


Power Rating)
All VGF GSID and
All VGF GL/GLD with HCR Propane6
All VGF GL with LCR only Propane6

VHP F2895/F3521/L5790
L7042/P9390GSI
VHP F3524/L5794/L7044GSI3
VHP GL
VHP L5774LT4
VHP L5794LT
VHP L5794LT with Low Fuel
Pressure System Option
VHP GSI and GL HD-5/Propane
(Including 3524/5794/7044GSI3)

8L-AT27GL
12V-AT27GL
16V-AT27GL2
16V-AT27GL EPG2

Altitude:
Temperature:
Altitude:
Temperature:
Altitude:
Temperature:
Jacket Water Temp.:
Altitude:
Altitude:
Altitude:
Temperature:
Altitude:
Temperature:
Altitude:
Temperature:
Jacket Water Temp.:

Deduct 2% for each 1000 ft. (305 m) above:


Deduct 1% for each 10F (5.5C) above:
Deduct 4% for each 1000 ft. (305 m) above:
Deduct 2% for each 10F (5.5C) above:
Deduct 2% for each 1000 ft. (305 m) above:
Deduct 1% for each 10F (5.5C) above:
Deduct 2.5% for each 10F (5.5C) above:
Deduct 2% for each 1000 ft. (305 m) above: (except GL LCR)
Deduct 6% for each 1000 ft. (305 m) above: (F18GL LCR only)
Deduct 5% for each 1000 ft. (305 m) above: (H24GL LCR only)
Deduct 1% for each 10F (5.5C) above:
Deduct 3% for each 1000 ft. (305 m) above:
Deduct 1.5% for each 10F (5.5C) above:
Deduct 2% for each 1000 ft. (305 m) above:
Deduct 1% for each 10F (5.5C) above:
Deduct 2.5% for each 10F (5.5C) above:
[210F (99C) maximum Jacket Water Temperature for GSID]
Altitude:
Deduct 6% for each 1000 ft. (305 m) above: (F18GL LCR only)
Deduct 5% for each 1000 ft. (305 m) above: (H24GL LCR only)
Temperature:
Deduct 1% for each 10F (5.5C) above:
Jacket Water Temp.:
Retard spark timing 2 above:
[210F (99C) maximum Jacket Water Temperature for GL with LCR]
Intercooler Water Temp. Retard spark timing 2 for each 10F (5.5C) above:
Altitude:
Deduct 2% for each 1000 ft. (305 m) above:
Temperature:
Deduct 1% for each 10F (5.5C) above:
Altitude:
Deduct 2% for each 1000 ft (305 m) above:
Temperature:
Deduct 1% for each 10F (5.5C) above:
Altitude:
Deduct 2% for each 1000 ft. (305 m) above:
Temperature:
Deduct 1% for each 10F (5.5C) above:
Altitude:
Deduct 2.4% for each 1000 ft. (305 m) above:
Temperature:
Deduct 2.4% for each 10F (5.5C) above:
Altitude:
Deduct 2.4% for each 1000 ft. (305 m) above:
Temperature:
Deduct 2.4% for each 10F (5.5C) above:
Altitude:
Deduct 4.8% for each 1000 ft. (305 m) above:
Temperature:
Deduct 4.8% for each 10F (5.5C) above:
Altitude:
Deduct 2% for each 1000 ft. (305 m) above (GL only):
Altitude:
Deduct 2% for each 1000 ft. (305 m) above (GSI only):
Altitude:
Deduct 2% for each 1000 ft. (305 m) above (Series Four GSI only):
Temperature:
Deduct 1% for each 10F (5.5C) above:
Jacket Water Temp.:
Deduct 2.5% for each 10F (5.5C) above:
Altitude:
Deduct 3.3% for each 1000 ft. (305 m) above:
Temperature:
Deduct 2% for each 10F (5.5C) above:
Altitude:
Deduct 4% for each 1000 ft. (305 m) above:
Temperature:
Deduct 2% for each 10F (5.5C) above:
Altitude:
Contact Waukesha Sales Engineering above:
Temperature:
Contact Waukesha Sales Engineering above:

Continuous/
Prime Power*

Intermittent/
Standby

3000 ft.
100F

1500 ft.
5000 ft.
3500 ft.
100F

5000 ft.
100F
180F

914 m
38C

457 m
1524 m
1067 m
38C

1524 m
38C
82C

1500 ft.
100F
1000 ft.
90F
1500 ft
85F
180F
1500 ft.
5000 ft.
3500 ft.
100F
1500 ft.
100F

5000 ft.
3500 ft.
100F
180F

1524 m
1067 m
38C
82C

130F
6000 ft.
100F
8000 ft.
100F
1500 ft.
100F
5000 ft.
100F
5000 ft.
100F
1500 ft.
100F
1500 ft.
6000 ft.
8000 ft.
100F
180F
3000 ft.
100F
6000 ft.
100F
1000 ft.
100F

54C
1828 m
38C
2438 m
38C
457 m
38C
1524 m
38C
1524 m
38C
457 m
38C
457 m
1828 m
2438 m
38C
82C
914 m
38C
1828 m
38C
305 m
38C

1500 ft.
100F
4000 ft
100F
1500 ft
85F

1500 ft
85F
1500 ft
85F

800 ft.
100F
6000 ft.
100F
800 ft.
100F

457 m
38C
1219 m
38C
457 m
29C

457 m
29C
457 m
29C

244 m
38C
1828 m
38C
244 m
38C

1500 ft.
100F
1500 ft
100F
180F

457 m
38C
457 m
38C
82C

500 ft.
85F

152 m
29C

457 m
38C
305 m
32C
457 m
29C
82C
457 m
1524 m
1067 m
38C
457 m
38C

Naturally Aspirated
All VHP, VGF and VSG
Natural Gas
All VHP, VGF, VSG
HD-5/Propane

Altitude:
Temperature:
Altitude:
Temperature:
Jacket Water Temp.:

Deduct 3% for each 1000 ft. (305 m) above:


Deduct 1% for each 10F (5.5C) above:
Deduct 3% for each 1000 ft. (305 m) above:
Deduct 5.5% for each 10F (5.5C) above:
Deduct 2.5% for each 10F (5.5C) above:

Rating Standard: All models: Ratings conform to ISO 3046/1 (latest version) with a mechanical efficiency of 90% and auxiliary water temperature, Tcra, as specified in the Power Rating Chart, Bulletin 1079 (latest version)
limited to 10 F (5.5 C). Ratings are also valid for SAE J1349, BS 5514, DIN 6271 and API 7B-11C standard atmospheric reference conditions.
Fuel Standard: All natural gas engine ratings are based on 900 BTU/ft3 (35.38 MJ/m3 [25, V(0; 101.325)]) SLHV, 91 WKI minimum, commercial quality natural gas. Refer to S-7884-7 (latest version) for full gaseous fuel specifications.
ISO Standard Power (Continuous Power Rating): The highest load and speed that can be applied 24 hours per day, seven days per week, 365 days per year except for normal maintenance at ISO standard ambient reference conditions. At ISO standard ambient reference conditions, it is permissible to operate the engine at up to 110% of the ISO Standard Power or the maximum power indicated by the intermittent rating, whichever is lower,
for two hours in every 24 hour period.
ISO Service Power (Site Continuous Power Rating): The highest load and speed that can be applied 24 hours per day, seven days per week, 365 days per year except for normal maintenance at the operating and ambient
conditions of the site application. Unless otherwise stated, it is permissible to operate the engine at up to 110% of the ISO Service Power (see the Overload Power definition) or the intermittent power rating available at the site
operating and ambient conditions, whichever is lower, for two hours in every 24 hour period.
Overload Power: The power that an engine is permitted to supply, with a duration and frequency of use depending upon the service application, at stated ambient conditions, immediately after operating at its ISO Service
Power rating. Unless otherwise stated, it is permissible to operate the engine at up to 110% of the ISO Service Power or the intermittent power rating available at the site operating and ambient conditions, whichever is lower,
for two hours in every 24 hour period. For situations without a defined intermittent power, the allowable 10% overload power is reduced from ISO standard ambient reference conditions by the applicable rating adjustments listed in the Intermittent/Standby Power column.
Intermittent Power Rating: The highest load and speed that can be applied in variable speed mechanical system applications only. Operation at this rating is limited to a maximum of 3500 hours per year.
Generator Continuous Power Rating (kWe): The highest load and speed which can be applied 24 hours per day, seven days per week, 365 days per year except for normal maintenance. Unless otherwise stated, it is permissible to operate the engine at up to 110% of the generator continuous power rating for two hours in every 24 hour period.
Generator Standby Power Rating (kWe): This rating applies to those systems used as a secondary source of electrical power. This rating is the output the system will produce continuously 24 hours per day for the duration
of the prime power source outage. No overload is allowed. This rating may reduce the lifecycle intervals.
Generator Peak Shaving Application Rating (kWe) For VHP Models Only: This rating is based on the number of horsepower-hours available per year in a constant speed application at site conditions. This rating allows for
limited engine operation above the published ISO Standard Power rating for VHP models only. This rating class requires a Special Application Approval. Contact Waukesha's Sales Engineering Department. This rating may
reduce the lifecycle intervals.
1 These altitude and temperature adjustments are meant to be a guide only and cannot be applied without limit. Contact Waukeshas Sales Engineering Department for additional information.
2 For 16V-AT27GL speeds other than 900 and 1000 rpm, contact Waukeshas Sales Engineering Department.
3 The F3524GSI, L5794GSI, and L7044GSI models are limited to 180F maximum jacket water temperature.
4 The L5774LT is rated for 130F intercooler water temperature only.
5 Unless otherwise specified, overload power is available for two hours in every 24 hour period at a level specified in the Definitions section or on a Special Application Approval.
6 For complete information regarding operation on propane and other fuels, including proper ignition timing, see the most current, model specific S-07079 series Technical Data Sheets.
*For Peak Shaving derates, contact the Waukesha Sales Engineering Department.

WAUKESHA ENGINE, DRESSER, INC. 1000 WEST ST. PAUL AVENUE, WAUKESHA, WI 53188-4999 T: 262-547-3311, FAX: 262-549-2795, WWW.WAUKESHAENGINE.DRESSER.COM
WAUKESHA ENGINE, DRESSER INDUSTRIAL PRODUCTS, B.V. FARMSUMERWEG 43, POSTBUS 330, 9900 AH, APPINGEDAM, THE NETHERLANDS T: (31) 596-652222, FAX: (31) 596-628111

All sales subject to standard terms of sale


including warranty and limitations of liability.
Bulletin No. 1079 - 20M 12/01

Das könnte Ihnen auch gefallen