Product data sheet

Characteristics

MVS12H3MW5L

EP MVS CB 1250A 65kA 3P MDO ET5 drawout manual Circuit breaker

Main
Range of product Circuit breaker name Device short name Circuit breaker application Poles description Protected poles description Network type Breaking capacity code Suitability for isolation Utilisation category Trip unit name Trip unit technology Trip unit rating EasyPact MVS MVS12H MVS12H Industrial 3P 3P 3d AC H - 65 kA Yes conforming to IEC 60947-2 ET5S Micro-processor based 1250 A (-5...70 C)
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Category B

Complementary
Network frequency Control type Mounting mode Mounting support Connection position Location of connection [In] rated current [Ui] rated insulation voltage [Uimp] rated impulse withstand voltage [Ue] rated operational voltage Circuit breaker CT rating Breaking capacity [Ics] rated service breaking capacity Mechanical durability Electrical durability 50/60 Hz Manually operated Drawout Base plate Rail Horizontal Vertical Rear 1250 A (40 C) 1000 V AC 50/60 Hz conforming to IEC 60947-2 12 kV conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 1250 A 65 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2 65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2 20000 cycles (with maintenance) conforming to IEC 60947-2 4000 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2 6000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2 115 mm (without spreader) Yes 143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 LSI Instantaneous short-circuit protection Overload protection (long time) Short time short-circuit protection Overload Short-circuit Internal fault 1

Connection pitch Contact position indicator [Icm] rated short-circuit making capacity [Icw] rated short-time withstand current

Trip unit protection functions Protection type

Fault indication

Aug 15, 2013

Long time pick-up adjstment type Ir Long time pick-up adjustment range Long time delay adjustment type [Tr] long-time delay adjustment Short-time pick-up adjustment type Isd [Isd] short-time pick-up adjustment range Short-time delay adjustment type [Tsd] short-time delay adjustment range Instantaneous pick-up adjustment type Ii Instantaneous pick-up adjustment range Zone selective interlocking ZSI Current sensor rating range Maximum breaking time Closing response time Height Width Depth Product weight

Adjustable 9 settings 0.4...1 x In Adjustable 9 settings 0.5...24 s (6 x Ir) Adjustable 9 settings 1.5...10 x Ir Adjustable 5 settings 100...400 ms Adjustable 9 settings 2...15 x In Off With 400/2000 A 25 ms < 70 ms 439 mm 441 mm 395 mm 70 kg

Environment
Standards Product certifications IEC 60947-2 CCC GOST IEC CCS IP40 4 conforming to IEC 60664-1 -5...70 C -25...85 C (with control unit) -40...85 C (without control unit)

IP degree of protection Pollution degree Ambient air temperature for operation Ambient air temperature for storage