EC type-examination Certificate

Number T10112 revision 8 Project number SO12200027 Page 1 of 1 Issued by NMi Certin B.V., designated and notified by the Netherlands to perform tasks with respect to conformity modules mentioned in article 9 of Directive 2004/22/EC, after having established that the Measuring instrument meets the applicable requirements of Directive 2004/22/EC, to: S.C. AEM S.A Calea Buziasului 26 300693 Timisoara Romania A Diaphragm Gas Meter Type Destined for the measurement of Accuracy class Environment classes Temperature range Location Further are described in the annexes Description T10112 revision 8 Documentation folder T10112-7 : : : : : : GN x / GNM x Gas volume Class 1,5 M2 / E1 See description T10112 revision 8 Closed

Manufacturer

Measuring instrument

Valid until Remarks

14 April 2018 This revision replaces the earlier versions, including its documentation folder.

Issuing Authority

NMi Certin B.V., Notified Body number 0122 21 February 2012

C. Oosterman Head Certification Board


NMi Certin B.V. Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands T +31 78 6332332 certin@nmi.nl www.nmi.nl This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability. The designation of NMi Certin BV.as Notified Body can be verified at http:// ec.europa.eu/enterprise/newapproach/nando/ Parties concerned can lodge objection against this decision, within six weeks after the date of submission, to the general manager of NMi (see www.nmi.nl). Reproduction of the complete document only is permitted.

500 101

Description
Number T10112 revision 8 Project number SO12200027 Page 1 of 3

General information about the gas meter


All properties of the gas meter, whether mentioned or not, shall not be in conflict with the legislation.

1.1

Essential parts Description Construction Diaphragm Valve and valve seat Temperature compensation Documentation 10112/2-02 10112/3-01 10112/0-06 10112/0-07 10112/0-08 10112/2-04 Remarks Description Material Synthetic rubber, manufacturer EFFBE France.

Applicable for GN G4TC and GN G4CT meters

1.2 1.2.1

Essential characteristics See EC Type-examination certificate no. T10112 Revision 8 and the characteristics mentioned below: Type GN G6(E/ET) GNM G6(E/ET) GN G4(E/ET) GNM G4(E/ET) GN G4CT(E) GN G4TC(E) GN G4T(E/ET) GN G2,5(E/ET) GNM G2,5(E/ET) Qmax [m3/h] 10 10 6 6 6 6 6 4 4 Qmin [m3/h] 0,060 0,060 0,040 0,040 0,040 0,040 0,040 0,025 0,025 Qt [m3/h] 1,0 1,0 0,6 0,6 0,6 0,6 0,6 0,4 0,4 V [dm3] 3,5 3,5 1,2 1,2 1,2 2,0 2,0 1,2 1,2 Tmin [C] -10 -25 -10 -25 -25 -25 -25 -10 -25 Tmax [C] +40 +55 +40 +55 +40 +40 +55 +40 +55 Maximum pmax [bar] 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5

1.3 1.3.1 1.3.2

Essential shapes The nameplate is bearing at least, good legible, the information as mentioned in the EN1359/A1. An example of the markings is shown in document no. 10112/2-03. Sealing: see chapter 2.

1
500

Description
Number T10112 revision 8 Project number SO12200027 Page 2 of 3 1.4 1.4.1 Conditional parts Construction In addition to the essential parts as mentioned at 1.1, the meter contains at least the following conditional parts: - housing; - transmission; - register. The meter can also be provided with low frequency impulse output. Housing The gas meter has a housing, which has sufficient tensile strength. The cover is made of steel sheet, the lower and upper case are connected with each other by a clamp. The register case is also connected to the upper case by screws. Examples of the housing are stated on documents no.s 10112/2-01, 10112/0-03, 10112/4-01 and 10112/6-01. 1.4.2 Transmission The transmission between the measuring part and the register is executed via a fixed mechanical (GNM) coupling or a magnetic (GN) coupling. When an electronic register is used the pulse transmission is checked using a three-pulse system. In document 10112/7-04 an example of the pulse transmission is shown. Register The indication can take place by two different means: - A mechanical register which indicates the volume in m3, by at least 5 drums before the comma and 3 drums after the comma. There can be two different versions of the mechanical register, see drawings no. 10112/2-05 and 10112/8-01 where examples of the counters are presented. - An electronic index register which indicates the volume in m3 on an LCD display with 9 digits of which at least 5 digits before the comma and 3 digits after the comma. The electronic index can optionally be equipped with temperature compensation. The use of the electronic register will results in an E or ET marking in the meter type. In documents no. 10112/7-01, 10112/7-02 and 10112/7-03 the drawings of the electronic register and its PCBs are presented. Adjustment The gas meter is adjustable by using the adjustment screw, see the adjustment instructions on document no. 10112/0-09. When equipped with the mechanical register as described in document no. 10112/8-01, the gas meter is also adjustable by choosing different gearwheel combinations as listed in document 10112/8-01, page 3. Software Measuring instrument type P Risk Class C; while extension L, T, D and S are not applicable or excluded. Software part Electronic register Version 1.2 Checksum 33 Remark The software version 1.2 and checksum 33 are presented on the display every 10 minutes for 6 seconds each.

1.4.3

1.4.4

1.4.5

2
500

Description
Number T10112 revision 8 Project number SO12200027 Page 3 of 3

1.5

Conditional shapes Connections Type Pipe configuration Minimum connection diameter [mm] 27 27 20 20 20 20 50 20 50 20 20 Maximum connection distance [mm] 250 250 165 165 165 250 250 165 165

GN G6(E/ET) GNM G6(E/ET) GN G4(E/ET) GNM G4(E/ET) GN G4CT(E) GN G4TC(E) GN G4TC(E) GN G4T(E/ET) GN G4T(E/ET) GN G2,5(E/ET) GNM G2,5(E/ET) 1.6 1.6.1 1.6.2 1.6.3 1.6.4 1.6.5

Double Double Double Double Double Double Single Double Single Double Double

Non-essential parts Reverse stop for preventing registration in reversed flow direction Pulse generator Serial communication through optical port Wired M-bus Radio M-bus

Seals
The following items of the meter are sealed: The entrance to the register is sealed with one or more seals. If a separate nameplate is used to show the pulse value this nameplate has to be sealed.

See drawings no. 10112/0-03 and 10112/8-01 page 1 for an example of the sealing.