BTA30
Adjust OUT

BTC12
CH1 Adjust CH2

BTC12
CH1 Adjust CH2

BTC12
CH1 Adjust CH2

BTC12
CH1 Adjust CH2

BTC12
CH1 Adjust CH2

BTC12
CH1 Adjust CH2

BTC12
CH1 Adjust CH2

BTC12
CH1 Adjust CH2

PS-BTC

Converted SAT-IF IN

Converted SAT-IF IN

Converted SAT-IF IN

Converted SAT-IF IN

Converted SAT-IF IN

Converted SAT-IF IN

Converted SAT-IF IN

Converted SAT-IF IN

Converted SAT-IF IN

IN

OUT

OUT

OUT

OUT

OUT

OUT

OUT

OUT

1536 1577

2089

1998 2038

1918 1958

1798 1878

1705 1758

1286 1369

1120 1162

Signal

Service Type PAL B, G OMI 14.74% Source

Pout 7.5dBm RIN -157.0dB/Hz Transmitter: ExMod.N 1550nm 7.5dBm

Pout 16.5dBm F 5.7dB

Ith 6.0pA/Hz Reff 0.95A/W Receiver: OCR2209 2400MHz

0.5dB

EDFA

29.8dB

C/N 54.0 dB

Noise Bandwidth 4.8MHz System Bandwidth 862MHz EDFA count 1

C/N 70.6dB acc. Fiber length 5km Fiber Type G652

Pin 7.0dBm C/N 70.8dB

Pin -13.3dBm C/N 49.54dB C/N Fiber 87.8dB @ 862MHz C/N total 48.16dB Output level 74.7dBV

Copyright BKtel communications GmbH 2011;

C/N rec. 48.00dB rec. level 64.0dBV

BKTEL_System_Designer_110927_Raman.xlsm CNR Simulation BC 14.10.2011

VERY HIGH POWER

OPTICAL AMPLIFIER

FOR

1550

NM

Application 4 Amplification of 1550 nm optical signals on single mode fibers 4 Video overlay in FTTH networks 4 CATV networks Features 4 Output powers of 16 x 16,5 dBm and 16 x 20 dBm 4 Cladding-pumped ErYb-doped fiber amplifier technology 4 Constant output power control 4 Input and output monitors 4 Dual, hot-plug-in power supply modules for 100 240 VAC or 36 72 VDC 4 Ethernet - Web and -SNMP Interface (a-Version) 4 RS232/RS485 control interface (b-Version) 4 LC display 4 General purpose I/O interface for remote functions 4 LED status indication 4 Very thin design, only 1 HU 4 OEM versions available

Technical Data
General Input signal wavelength Optical output power Wavelength of pump lasers (typ.) Optical return loss Min. optical input level Max. optical input level Polarization dependent gain Noise figure (@Pin=0dBm, =1550nm) Optical isolation @ input Optical isolation @ output [nm] [dBm] [nm] [dB] [dBm] [dBm] [dB] [dB] [dB] [dB] 1545 - 1565 16 x 16,5 0.5 16 x 20 0.5 < 1000 nm >45 -5 +10 0.5 <5.5 35 35

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

BaalFTTx Series
1

Fx-OV16xxx

FTTx

F X- OV 1 6 x x x

FTTX

Electrical and Mechanical Properties Optical connector input Optical connector output Optical fiber Power consumption Climatic specification Operation Storage EMI Power supply Dual redundant, hot pluggable Enclosure E2000 or SC/APC LC/APC or SC/APC standard singlemode 9/125 m < 45 W ETS 300 019, class 3.1 ETS 300 019, class 1.2 EN50083-2 (April 1996) EN50083-2 /A1 (February 1998) 100 240 VAC or 36 72 VDC 19 / 1 RU

Fx-OV16xxx

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

Specifications subject to change without notice - DB_Fx-OV16xxx_21012009.doc

BaalFTTx Series

TRANSPONDER AMPLIFIER MODULE Application The BTA30 Module amplifies the SAT-IF signal and combines it with the CATV signal. Combines the two SAT-IF signals from two BTC chassis. Features Two SAT-IF inputs to multiplex two SAT-IF input signals. A separate CATV input to combine CATV and SAT-IF.

General Technical Data Input/output connectors Number of inputs DC pass for LNB Input frequency SAT-IF Input level SAT-IF Gain 2dB Input frequency CATV Insertion loss CATV CATV Signal rejection (SAT-IF input) Output frequency (CATV + SAT-IF) [mA] [MHz] [dBV] [dB] [MHz] [dB] [dB] [MHz] F 2 inputs for SAT-IF + 1 input for CATV max. 500 @ 17V 9502300 59

15862 <2 36 (15862MHz) 152300 125 @ 2150MHz 20 272 x 166 x 45 1,2 050

Output level DIN 45004B (IM3 -35dB) [dBV] Output level regulation Outer dimensions Weight Operating temerature [dB] [mm] [kg] [C]

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

Fiber.xSAT Series
1

BTA30

38 @ 950MHz 46 @ 2150MHz 40 @ 2300MHz

FTTx

BTA30

SATELLITE TRANSPONDER CONVERTER MODULE Application Satellite Transponder Converter with programmable transponder conversion for usage in a single cable head end. Converters two analog or digital transponders from one or two independent inputs. Features Built-in AGC for a constant output level. Adjustable output power. Input signal forwarding

General Technical Data Number of inputs Module capacity Input/output connectors Input frequency Input level Troughput loss Return loss DC pass for LNB Output bandwidth Phase noise (F. in 950MHz, F. out 2150MHz) Output frequency Output level Output level regulation Output frequency stability Level stability (25C 20C) AGC Selectivity Outer dimensions Weight Operating temerature [mm] [kg] [C] [MHz] [dBV] [dB] [dB] [mA] [MHz]

BTC12 1 2 Transponders F 9502150 4987

BTC22 2 independent

>8 max. 500 @ 17V 27 / 36 / 40 (switchable)

[dBc/Hz] -75 @ 10 kHz [MHz] [dBV] [dB] [MHz] [dB] [dB] 9502150 >78 20 0,15 2 >40

272 x 166 x 45 1,6 050 1

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

Fiber.xSAT Series

BTCn2

<1,5

FTTx

BTCn2

Passive FTTH Network Termination Box with Optional Optical CATV/SATTV Receiver Module

Application The FWO is a universal wall outlet for termination of in-house fiber optic cabling. It provides a comprehensive solution for the fiber deployment in MDUs including: the passive fiber termination for up to 8 fibers the active termination of optical CATV/SAT-TV signals in combination with the BKtel Optical Compact Receiver OCR (optional) an optical path through port in order to connect GPON/GEPON or EPTP FTTH customer premises equipment (optional)

Features 4 Fiber termination box for up to 8 low bending loss fibers (G.657A). 4 Universal splice holders for heat shrink splices or crimp splices included (8, 4 with installed Receiver Module). 4 Up to 4 Simplex SC adaptors or 4 Duplex LC adaptors on front for passive fiber termination. 4 Carrier for BKtel Optical Compact Receiver (OCR). 4 If the OCR module is installed, up to 2 Simplex SC adaptors or 2 Duplex LC adaptors can additionally be installed 4 Possibility to lock and seal the housing with a supplied screw and seal 4 Bottom /top/rear access for fiber break out cables
BKtel communications GmbH www.bktel.com Email: sales@bktel.com

1
All Rights Reserved FWO BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com BaalFTTx Series All Rights Reserved BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

FTTx

FWO

BKtel communications GmbH www.bktel.com Email: sales@bktel.com

Applications

FTTx
Specifications Physical and Environmental Dimensions (height, depth, width) Optical connector Optical Receiver Kit Optical receiver modules Optical connector CATV/SAT-TV interface Power Supply Power supply interface (DC IN)
All rights reserved. Specifications and availability subject to change without notice - DBe_FWO_101214

35 mm x 80 mm x 140 mm SC or LC

BKtel communications GmbH www.bktel.com Email: sales@bktel.com

OCR1016E, OCR2209E, OCR1016E-WDM and OCR2209EWDM, for detailed specifications please contact BKtel SC/APC F-female, 75 Plugin Power Supply Unit 6V/2A 2.1/5.5mm connector

Available Types Type FWO Passive FTTH termination box

2 BaalFTTx Series FWO

O C R 2 2 0 9 E -W D M
COMPACT
OPTICAL RECEIVER

MODULE

WITH INTEGRATED OPTICAL

DEMULTIPLEXER

Application 4 Receiver module for optical networks with CATV and SAT IF signal distribution, HFC and FTTx nodes Features 4 Ultra low noise push-pull technology 4 Bandwidth of 2.4 GHz 4 46 dB CNR (typ.) for NTSC with OMI = 4% at 8 dBm optical input power @ 1550 nm 4 20 dBmV RF output level (-5 dBm, 1550 nm, OMI = 4%) 4 Very low intermodulations 4 Low power consumption 4 Small package with single-mode fiber pigtail 4 Integrated optical demultiplexer (WDM filter) for RF overlay applications 4 Monitor voltage output and output disable input 4 Status LEDs for input power ok and output enabled Technical Data
Electrical/Optical Characteristics Parameter Optical Input Power Opt. Wavelength for Receiver Opt. Wavelength for IP port Opt. Wavelength for COM port Opt. Insertion Loss COM-IP Opt. Isolation IP1/2 at Receiver Opt. Isolation CATV at IP port Optical Return Loss Power Supply Voltage Power Supply Current Monitor Voltage Fiber Opt. Connector RF-Connector *) Specifications are without fiber connectors COM (CATVin & IPin/out) IP in/out Symbol PIN CATV IP1 IP2 CATV, IP1/2 ATTCOM-IP ISLCATV ISLIP ORL Vcc ICC UCRXPO Min -10 1539 1260 1480 1550 1310 1490 Typ Max 0 1565 1360 1500 0.8 *) 35 *) 20 *) 35 45 5/6 180 Iphoto * 1000 standard single-mode fiber G652 or low bending fiber G657A SC/APC or LC/APC SC/PC or SC/APC or LC/PC or LC/APC F (female) 200 Unit dBm nm nm nm dB dB dB dB V mA V OCR2209E-WDM
IP
WDM

COM
Re ceiver

5 4 3 1

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

BaalFTTx Series
1

OCR2209E-WDM

FTTx

RF Characteristics

FTTX

Parameter RF Bandwidth Receiver Noise Current RF Impedance RF Return Loss CATV (47-862 MHz) RF Return Loss SAT IF (> 950 MHz) Flatness Output Isolation (output disabled) RF Output Level *) CSO for Cenelec 42 **) CTB for Cenelec 42 **)

Symbol B IENC Z

Min 47

Typ 6

Max 2400 6.5 -

Unit MHz pA/Hz dB dB

14 @ 47 MHz, -1 dB/oct. 6

75

-2.5 40

+2.5

dB dB

L CSO CTB

18 63 (PIN= 0 dBm) 61 (PIN= 0 dBm)

20 >70 (PIN= -5 dBm) >70 (PIN= -5 dBm)

22

dBmV dB dB

*) PIN= -5 dBm, 1550 nm, OMI = 4%, RF level decreases with 2:1 law with optical input power **) CSO/CTB contribution of OCR for Cenelec 42 signal according IEC 60728-3 / EN 50083-3, OMI = 4.1%, 1550 nm

Absolute Maximum Ratings Parameter Operating Temperature Range Storage Temperature Range Optical Input Power Power Supply Voltage Symbol TOP Tstg PIN VCC 4.5 Min -10 -40 Max +60 +85 0 6 Unit C C dBm VDC

OCR2209E-WDM

CATV Disable The CATV disable pin 5 allows to deactivate the RF output by a 0-0.8V logic signal level; a 10 kOhms pull-up to VCC is internally connected to this pin (low=deactivated).

Diagnostic LEDs Normal Operation Optical Input Power low CATV Disabled CATV Enabled Mechanical Outlines Optical Input Power LED: lightening green Optical Input Power LED: off Power LED: off
Specifications subject to change without notice - DBe_OCR2209E-WDM_20091209.doc

preadjusted for 14+/-1dBm

Power LED: lightening green

BaalFTTx Series
2

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

Connector Pin Description Pin No. 1 2 3 4 5 Description VCC N.C. GND UCRXPO Output Disable Power Supply not connected GND Received optical power: The measured monitor voltage is the product of photodiode current and 1000 10 kOhms pull-up to VCC, CATV signal disabled, if connected to GND

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

BaalFTTx Series
3

OCR2209E-WDM

FTTx

POWER SUPPLY Application

FOR

SATELLITE TRANSPONDER CONVERTER MODULE

Power Supply for usage in BTC-chassis. Features Powers up to 9 BTC modules in one BTC Chassis.

General Technical Data Output voltage 5% Output current 90W Max. absolute current per output Max. total output power Outer dimensions Weight Operating temerature [Vdc] [A] [A] [W] [mm] [kg] [C] 30 0,016 0,15 106 272 x 166 x 45 24 0,4 1,3 17 0,3 0,4 12 2,9 3,8 5 7,9 9,6

050

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

Fiber.xSAT Series
1

PS-BTC

1,6

FTTx

PS-BTC

DUAL L-BAND Application

FREQUENCY

STACKER

4 Stacking of 2 L-Band signals (950-2150 MHz) in the frequency range from 950- 3750 MHz 4 Usage as headend for optical transmission system of Satellite-IF signals (BKtel Fiber.2SAT) Features 4 Upconversion of one L-Band (950-2150 MHz) into the frequency range from 2550 3750 MHz and multiplexing with second L-band signal in the baseband (950-2150 MHz)

General Technical Data


Input Frequency range Input Impedance Number of Inputs Input Power Input Return loss Output Frequency Range Output Impedance Number of Outputs Output Return loss Output Power Gain Gain Variation (-30 to +60 C) AGC Range AGC Threshold Manual Attenuator Loss [dB] [dBm] [dB] [dB] dB dBm dB [dBm] [dB] [MHz] [] [MHz] [] 2x 950... 2150 75 2 (F-type) -25 (per transponder), -10 (32 transponders) Typ. 10 SAT-IF-IN (H) and SAT-IF-IN (V)

50 1 (N-type ) Typ. 10 -28 (per transponder), -10 (64 transponders) 29 3 Min. 19 Typ. -26 323 Total input power level

950-2150MHz or 25503750MHz

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

BaalFTTx Series
1

Below AGC threshold and at min manual attenuator loss

2SAT-S

950 3750 (950-2150, 2550-3750)

FTTx

2 S A T- S

L.O. Frequency

[GHz] kHz degree RMS dBm VDC

4.70 -150 ...+150 Max. 4

FTTX

Synthesiser with external 25MHz XCO 0 to 50C temperature range Integrated from 1kHz to 10MHz Or ASTRA IF-IF Converters Spec

LO Frequency Accuracy

LO Phase Noise

OIP3 Supply Voltage, Nominal

TBD 20

Below ALC threshold and at min. manual attenuator loss Internal 6V DC-DC converter. It is possible to use external power supply from 12V to 21V For 20V power supply

Current Consumption EMC Climatic Specification- Operation Climatic Specification- Storage Dimensions (w x h x d)

mA

<300 EN50083-2

[C] [C] mm

-0 ...+50 -10 ...+50 244x206x28mm

Ordering Information
For more information on this product please contact BKtel communications.

2SAT-S

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

Specifications subject to change without notice - DBe-2SAT-S_100812

BaalFTTx Series

AMPLIFIED OPTICAL TRANSMITTER

FOR

CATV

AND

SAT IF TRANSMISSION

Application

4 Electrical to optical conversion of multichannel CATV signals like AM-VSB, FM, QAM, DTT, DVB-T and DAB signals 4 Electrical to optical conversion of SAT IF video signals like QPSK, 8-PSK and 16QAM by separate input 4 Optical amplification in order to realize several optical outputs to drive FTTx and/or HFC networks 4 Video overlay with 1550 nm wavelength in FTTx networks providing very high optical budget (GPON compatible)

Features 4 Bandwidth of 5870 MHz for CATV and 9502610 MHz for SAT-IF input 4 All-electronically adjustments for CATV input: slope, gain, output power, OMI, pre-chirping etc. 4 Automatic load control (ALC) for constant OMItotrms of CATV signals 4 Separate RF input for SAT-IF signals

4 SBS suppression and prechirping technology 4 Cladding-pumped ErYd-doped fiber amplification technology with constant output power control 4 Optical output port monitor 4 Dual, hot-plug-in power supply modules for 100240 VAC or 3660 VDC 4 Web and SNMP interface 4 LC display and LED status indication 4 General purpose I/O interface for remote functions 4 Very thin, only 1 U design for mounting into 19, ETSI or JIS racks

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

BaalFTTx Series
1

4 Front panel RF test point 20 dB

Fx-AOT08200, Fx-AOT16200

FTTx

Fx-AOT08200, Fx-AOT16200

Block Diagram

Fx-AOT08200, Fx-AOT16200

FTTX

General Technical Data


Wavelength Optical output power Polarization dependence Side mode suppression Optical isolation Optical return loss SBS threshold
1,2,3

[nm] [dBm] [dB] [dB] [dB] [dB] [dBm] [dBm]

1550 1560 +20 0.5 dB 0.5 dB > 30 35 > 40 +21 for 10 km fiber length +19 for 20 km fiber length F-female, 75, front side mounted LC/APC, front side mounted Standard single mode 9/125 m RJ45, rear side mounted RJ45, rear side mounted Mini, rear side mounted ETS 300 019, class 3.1 ETS 300 019, class 1.2 EN 50083-2 EN 60950, Laser class 1M according IEC 60825-1 (eyesafe for normal viewing) 100 ... 240 VAC or 3660 VDC (dual redundant, hot pluggable) < 65 W power consumption 19 / 1 rack unit [RU] (optionally compatible to ETSI or JIS standards)

RF-connectors/ impedance

Optical connectors Optical fibre Control interfaces Ethernet 10/100 Mbps BKtel RS485 bus I/O ports Climatic specification Operation Storage EMI Safety Power supply Enlosure dimensions Weight [kg]

9 (including two power supplies)

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

Specifications subject to change without notice - DBe-Fx-AOT_20110209.docx

BaalFTTx Series

CATV Signal Data

Frequency range Frequency response at 80 dBV / 5% 5 7 MHz 7 47 MHz 47 606 MHz 606 870 MHz Return loss 5 47 MHz 47 870 MHz Input level (referred to OMI = 5%) Gain adjustment range

[MHz] [dB] [dB] [dB] [dB] [dB] [dB] [dBV] [dB]

5 870 1.5 0.75 0.5 0.75 18 20 (at 47 MHz) 1.5 dB/oct., min. 15 73 minimum 0 24 -3 (cable equivalent) +16 (cable equalization) 20 > 46 > 45 > 60 4) > 56 4) > 63 > 58 5) > 52 5)

Slope adjustment range (10870 MHz) [dB] Testpoint attenuation CNR ) 47 600 MHz 600 862 MHz CSO 1,2) 47 600 MHz 600 862 MHz CTB 1,2)
1,2,3

[dB] [dB] [dB] [dB] [dB] [dB]

SAT IF Signal Data


SAT-IF input impedance Frequency range Frequency response Return loss 950 1750 MHz 1750 2610 MHz Nominal input level per SAT IF carrier CNR 1,3) referred to nominal SAT IF carrier Spurious signals 1,4) referred to nominal SAT IF carrier [] [MHz] [dB] [dB] [dB] [dBV] [dB] [dB] 75 950 2610 2 10 6 90 3) > 24 > 34

Test Conditions
1

) ) ) ) )

Popt,in= -6 dBm, appropriate receiver technology with Ieq= 4 pA/Hz and = 0.95 A/W (at 1550 nm) used, CATV and SAT-IF signals transmitted together (see also test condition 4 below) C42 channel allocation with OMI= 3.9% measured with 5 MHz noise bandwidth 36 SAT-IF carriers with OMISAT= 1.0% for SAT-IF carriers, measured with 27 MHz noise bandwidth Internal prechirping parameter fiber length compensation set according to connected optical fibre length Internal prechirping parameter fiber length compensation set to 7 km, actual fiber length between 0 12 km

2 3 4 5

Available Types
Fx-AOT08200 Fx-AOT16200 Amplified optical transmitter with 8 ports of 20.0 dBm optical output power each Amplified optical transmitter with 16 ports of 20.0 dBm optical output power each

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

BaalFTTx Series
3

Fx-AOT08200, Fx-AOT16200

FTTx

CATV input impedance

[]

75

OPTICAL CATV

AND

SAT-IF TRANSMITTER

Application

4 Electrical to optical conversion of multichannel CATV signals like AM-VSB, FM and QAM signals 4 Electrical to optical conversion of SAT-IF video signals by separate input 4 The 1550nm versions enable the usage of optical amplifiers (EDFAs) as boosters or repeaters in order to realize FTTx HFC networks

Features 4 SBS suppression with very high SBS threshold and 1550 nm pre-chirping technology

4 All-electronically adjustments for CATV input: slope, gain, output power, OMI, pre-chirping etc. 4 Automatic load control (ALC) for constant OMItotrms of CATV signals 4 Linearity optimized versions either for European Cenelec 42 or for Japanese NTSC74 channel allocation 4 Separate RF input for SAT-IF signals 4 ITU-Grid wavelength, wavelength adjustable 100 GHz 4 Front panel RF test point 20 dB 4 Dual, hot-plug-in power supply modules for 100240 VAC or 3672 VDC 4 Web and SNMP Interface 4 LC display and LED status indication 4 General purpose I/O interface for remote functions 4 Very thin, only 1 U design for mounting into 19, ETSI or JIS racks

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

BaalFTTx Series
1

Fx-DS26

4 Bandwidth of 5870 MHz for CATV and 9502610 MHz for SAT-IF input

FTTx

Fx-DS26

Block Diagram

FTTX

SATIN BCIN
20dB

OUT TP

RMS

LEDs LCD Panel Push Buttons

NEC-E

RS485 Ethernet I/O Ports

P
DC AC/DC

Power in

DS26 Fx-DS26

DC AC/DC

General Technical Data


Wavelength [nm] Type 1310: 1290 1330 Type 1550 : 1540 1560 Type DWmm : according to ITU grid no. mm Type DWmm: -100 +100 in steps of 50 Type 70: Type 80: Type 110: Type 130: > 30 < -155 Type 1310: +16.0 Type 1550: +18.0 Type DWmm: +18.0 Any type of high return loss connectors rear side mounted Standard single mode 9/125 m F-female, 75, rear side mounted Ethernet 10/100 interface ETS 300 019, class 3.1 ETS 300 019, class 1.2 EN50083-2, EN50083-2 /A1 EN 50083-1 and EN 60950, Laser class 1M according IEC 60825-1 (eyesafe for normal viewing) 100 ... 240 VAC, or 36 ... 72 VDC < 25/34 VA (1/2 power supplies) < 21/25 W (1/2 power supplies) 19 / 1 rack unit [U] (optionally compatible to ETSI or JIS standards) [kg] 9 (including two power supplies)
Specifications subject to change without notice - DBe-Fx-DS26_05012010.doc

Wavelength adjustment range Optical output power

[GHz] [dBm]

+7 +10 +8 0.5 +11 0.5 +13 0.5

Side mode suppression

[dB] [dBc/Hz] [dBm]

Fx-DS26

Relative intensity noise (optical return loss > 40 dB) SBS suppression 1) 3) 4) (measured for 25 km fiber length and NTSC74 or Cenelec42 input) Opt. connector Optical fibre

BaalFTTx Series

RF-connector/ impedance Control interface Climatic specification Operation Storage EMI Safety Power supply Dual redundant, hot pluggable Power consumption 110 VAC 48 VDC Enlosure dimensions Weight

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

CATV Signal Data

Frequency range Frequency response at 80 dBV / 5% 5 7 MHz 7 47 MHz 47 606 MHz 606 870 MHz Return loss 5 47 MHz 47 870 MHz Input level (referred to OMI = 5%) Gain adjustment range

[MHz] [dB] [dB] [dB] [dB] [dB] [dB] [dBV] [dB]

5 870 1.5 0.75 0.5 0.75 18 20 (at 47 MHz) 1.5 dB/oct., min. 15 73 minimum 0 24 -3 (cable equivalent) +16 (cable equalization) 20 1310 -nnn-C42 51 3) 50 3) 65 3) 64 3) 1310 -nnn-N74 51 4) 50 4) 65 4) 64 4) 1550/DWmm -70-C42 50.5 3) 49 3) 53 2)3) (f<600 MHz: 58) 62 3) 1550/DWmm -70-N74 50.5 4) 49 4) 58 2)4) 62 4)

Slope adjustment range (10870 MHz) [dB] Testpoint attenuation Version CNR 1) 0 15 km fibre length 15 25 km fibre length CSO 1) CTB 1) [dB] Fx-DS26-

[dB] [dB] [dB] [dB]

SAT-IF Signal Data


SAT-IF input impedance Frequency range Frequency response Return loss Version Nominal input level per SAT-IF carrier CNR 1) referred to nominal SAT-IF carrier Spurious signals referred to nominal SAT-IF carrier [] [MHz] [dB] [dB] Fx-DS26[dBV] [dB] [dB] 75 950 2610

10 1310 -nnn-C42 92 5) 27 5) 35 5) 1310 -nnn-N74 90 6) 25 6) 40 6) 1550/DWmm -70-C42 92 5) 27 5) 35 5) 1550/DWmm -70-N74 90 6) 25 6) 40 6)

Test Conditions
1

) Popt,in= 0 dBm, appropriate receiver technology with Ieq= 7.0 pA/Hz and = 0.95 A/W (at 1550 nm) used, CATV and SAT-IF signals transmitted together (see also test conditions 5 and 6 below) ) Internal prechirping parameter flc set according to connected fibre length: 010km / flc=5km, 515km / flc=10km, 1020km / flc=15km, 1525km / flc=20km

3 4 5

) European Cenelec 42 channel allocation with OMI= 4.1% measured with noise bandwidth of 5 MHz ) Japanese NTSC74 channel allocation with OMI= 3.3% measured with noise bandwidth of 4 MHz ) 10 dB backoff of SAT-IF carriers refered to CATV video carriers, 36 QPSK modulated SAT-IF carriers with 27 MHz IF bandwidth, OMISAT= 1.3% for SAT-IF carriers, Cenelec42 carriers with OMI= 4.1%, 27 MHz noise bandwidth ) 10 dB backoff of SAT-IF carriers refered to CATV video carriers, 36 QPSK modulated SAT-IF carriers with 27 MHz IF bandwidth, OMISAT= 1.0% for SAT-IF carriers, NTSC74 carriers with OMI= 3.3%, 27 MHz noise bandwidth

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

BaalFTTx Series
3

Fx-DS26

FTTx

CATV input impedance

[]

75

Ordering Information

FTTX

For more information on this product please contact BKtel communications. Properties for ordering optical transmitter Fx-DS26:

Optical output power

70 80 110 130 C42 N74 0 1 1310 1550 DWmm 1 2 3 4 5 F R 0 OEM 230/230 48/48 230 48 230/48

+7.0 dBm +8.0 dBm +11.0 dBm +13.0 dBm Cenelec 42 NTSC 74 No Yes 1310 nm 1550 nm DDM ITU grid no. mm E2000 SC/APC FC/APC-NTT FC/APC-JDS SC/APC with shutter on front side on rear side BKtel OEM 2 x (100240 VAC) 2 x (3672 VDC) 1 x (100240 VDC) 1 x (3672VDC) mixed 230 VAC / 48 VDC

Frequency plan *)

I/O ports

Wavelength

Optical connector

RF input / optical output

Version

Fx-DS26

Power supply

*) Other frequency plan on request!


Specifications subject to change without notice - DBe-Fx-DS26_05012010.doc

BaalFTTx Series

Available Types
Fx-DS26-1310-80-C42, Fx-DS26-1310-110-C42 and Fx-DS26-1310-130-C42 Fx-DS26-1310-80-N74, Fx-DS26-1310-110-N74 and Fx-DS26-1310-130-N74 Fx-DS26-1550-70-C42 and Fx-DS26-1550-70-N74 Fx-DS26-DWmm-70-C42 and Fx-DS26-DWmm-70-N74 with mm=21, 23, 45

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

OPTICAL TRANSMITTER

Application

4 Electrical to optical conversion of SAT-IF and multichannel CATV signals like AM-VSB, FM and QAM signals 4 Enables the usage of optical amplifiers (EDFAs, YEDFAs) as boosters or repeaters in order to realize FTTx networks

Features 4 Bandwidth SAT-IF 9503750 MHz 4 Bandwidth CATV 5870 MHz

4 Automatic load control (ALC) for constant OMItotrms 4 Front panel RF test points 20 dB 4 Dual, hot-plug-in power supply modules for 100240 VAC or 3060 VDC 4 Web and SNMP Interface 4 LC display and LED status indication 4 General purpose I/O interface for remote functions 4 Very thin, only 1 U design for mounting into 19, ETSI or JIS racks

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

BaalFTTx Series
1

Fx-DS40

4 All-electronically adjustments of gain, output power and optical modulation index (OMI)

FTTx

Fx-DS40

General Technical Data

FTTX

Wavelength

[nm]

Type 1550 :

1540 1560nm

Type DWmm : according to ITU grid, CH35...CH48 Optical output power Side mode suppression Opt. connector Input impedance Frequency range Frequency response Return loss Input level Optical fibre RF-connector/ impedance [] [MHz] [dB] [dB] [dBm] [dBm] [dB] 8 1 > 30 Any type of high return loss connector 50 SAT-IF: 9503750 MHz CATV: 5...870 MHz 2 6 -10 8 Standard single mode 9/125 m CATV: F-female, 75 front or rear side mounted CATV test point: F-female, 75 front side mounted SAT: N-type, 50 rear side mounted SAT test point: SMA, 50 front side mounted Control interface Climatic specification Operation Storage EMI Safety Power supply Dual redundant, hot pluggable Ethernet 10/100 interface ETS 300 019, class 3.1 ETS 300 019, class 1.2 EN50083-2, EN50083-2 /A1 EN 50083-1 and EN 60950, Laser class 1M according IEC 60825-1 (eyesafe for normal viewing) 100 ... 240 VAC, or 36 ... 72 VDC < 25/34 VA (1/2 power supplies) < 21/25 W (1/2 power supplies) 19 / 1 rack unit [U] (optionally compatible to ETSI or JIS standards) [kg] 9 (including two power supplies)

Fx-DS40

Power consumption 110 VAC 48 VDC Enlosure dimensions Weight

Available Types
Fx-DS40-1550-80 Fx-DS40-DWmm-80, mm=35, 36, 48

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

Specifications subject to change without notice - DBe-Fx-DS40_100608

BaalFTTx Series

ULTRA BROADBAND OPTICAL RECEIVER MODULE DESTACKER+MULTISWITCH + TERRESTRIAL

Application 4 Optical receiver and frequency destacking module for stacked Satellite-TV-signals in BKtel Fiber.2SAT optical transmission system ( to be used with 2SATS dual L-band frequency stacker unit) 4 Usage as optical receiver unit for Satellite-TV video overlay in FTTH networks Features 4 O/E conversion and frequency destacking of multiplexed SAT IF signals 4 Suitable for 2 stacked L-band signals (950-2150 MHz each) 4 2x4 multiswitch included 4 Reception of terrestrial TV (analog terrestrial (TV and Radio), DVB-C, DVB-T (DTT) or DAB signals

Technical Data
Optical and RF Characteristics Parameter Input Optical Wavelength Input Optical Power Optical Return Loss Input RF Frequency Range Total Input RF Power Input RF Power Noise Figure Output Frequency Range SAT-IF Output Frequency Range Trerrestrial Max Gain AGC Range AGC Threshold Nominal Output Power Gain Ripple and Variation OIP3 Isolation 9 26 32 -37 30 -56 -34 -31 6 950 47 40 Min 1310 -18 20 47 -56 -74 3750 -26 -44 4 2150 854 Typ Max 1550 -3 Unit nm dBm dB MHz dBm dBm dB MHz MHz dB dB dBm dBm dB dBm Total input RF power Average per transponder At 950-2150 output frequency band Below AGC threshold Unwanted path to selected path Below AGC threshold Terrestrial 47-854, SAT-IF 950-3750 Total of 64 transponders Per transponder After photodiode @ max gain SAT-IF-IN (H) or SAT-IF-IN (V)

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

BaalFTTx Series
1

XON80.2SAT-MT

FTTx

X O N 8 0 . 2 S A T- M T

FTTX

Parameter In Band Spurious Out of Band Spurious Output Impedance LO Frequency LO Frequency Accuracy LO Phase Noise

Min 25

Typ

Max

Unit dBc

-50 75 4700 -150 +150 4

dBm Ohm MHz kHz Degree RMS

Output power level

0 to 50C temperature range Integrated from 1kHz to 10MHz or ASTRA IF-IF Converters Spec

General Technical Data Parameter Operating Temperature Range Storage Temperature Range Power Supply Voltage Current Consumption Select SAT-IF-IN (V) Select SAT-IF-IN (H) Optical Connector RF Output Connectors 15 Min -10 -40 20 140 13 18 SC/APC 5x F-female 165x 155 x 30 mm XON80.2SAT-MT 14 Typ Max +60 +85 Unit C C V mA V V For 20V power supply Not converted path selected Converted path selected

XON80.2SAT-MT

Dimensions

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

Specifications subject to change without notice - DBe-XON80 2SAT-MT_20110622

BaalFTTx Series

ULTRA BROADBAND OPTICAL RECEIVER MODULE DESTACKER+MULTISWITCH + TERRESTRIAL + WDM

Application 4 Optical receiver and frequency destacking module for stacked Satellite-TV-signals in BKtel Fiber.2SAT optical transmission system ( to be used with 2SATS dual L-band frequency stacker unit) 4 Usage as optical receiver unit in PON-FTTH networks (GPON and GEPON) with Satellite-TV RF video overlay Features 4 O/E conversion and frequency destacking of multiplexed SAT IF signals 4 Suitable for 2 stacked L-band signals (950-2150 MHz each) 4 2x4 multiswitch included 4 Reception of terrestrial TV (analog terrestrial (TV and Radio), DVB-C, DVB-T (DTT) or DAB signals 4 Integrated WDM module: 1 common optical in/out port (2SAT video overlay + PON Data ), 1 optical in/out port PON Data Technical Data
Optical and RF Characteristics Parameter Input Optical Wavelength Input Optical Power Optical Return Loss Input RF Frequency Range Total Input RF Power Input RF Power Noise Figure Output Frequency Range SAT-IF Output Frequency Range Trerrestrial Max Gain AGC Range AGC Threshold Nominal Output Power Gain Ripple and Variation OIP3 Isolation 9 26 32 -37 30 -56 -34 -31 6 950 47 40 Min 1310 -18 20 47 -56 -74 3750 -26 -44 4 2150 854 Typ Max 1550 -3 Unit nm dBm dB MHz dBm dBm dB MHz MHz dB dB dBm dBm dB dBm Total input RF power Average per transponder At 950-2150 output frequency band Below AGC threshold Unwanted path to selected path Below AGC threshold Terrestrial 47-854, SAT-IF 950-3750 Total of 64 transponders Per transponder After photodiode @ max gain SAT-IF-IN (H) or SAT-IF-IN (V)

BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com

BaalFTTx Series
1

XON80.2SAT-MT-WDM

FTTx

X O N 8 0 . 2 S A T- M T- W D M

FTTX

Parameter In Band Spurious Out of Band Spurious Output Impedance LO Frequency LO Frequency Accuracy LO Phase Noise Technical Data WDM Operating Wavelength Pass Band Operating Wavelength Reflect Band Optical Connector

Min 25

Typ

Max

Unit dBc

-50 75 4700 -150 +150 4

dBm Ohm MHz kHz Degree RMS

Output power level

0 to 50C temperature range Integrated from 1kHz to 10MHz or ASTRA IF-IF Converters Spec

15391565 nm XON80.2SAT-WDM-xPON 15401549 nm XON80.2SAT-WDM-xPON&CATV PON Data in PON Data out 2SAT, PON in/out PON in/out 12601360 nm 14801500 nm SC/APC SC/APC < 0.8 dB > 35 dB > 35 dB > 15 dB
Specifications subject to change without notice - DBe-XON80 2SAT-MT-WDM_20110812

XON80.2SAT-MT-WDM

Insertion Loss Reflect Port (COM PON) Return Loss Isolation Pass Isolation Reflect

General Technical Data Parameter Operating Temperature Range Storage Temperature Range Power Supply Voltage Current Consumption Select SAT-IF-IN (V) Select SAT-IF-IN (H) 15 Min -10 -40 20 140 13 18 SC/APC 5x F-female 165x 155 x 30 mm XON80.2SAT-MT 14 Typ Max +60 +85 Unit C C V mA V V For 20V power supply Not converted path selected Converted path selected

BaalFTTx Series

Optical Connector RF Output Connectors Dimensions