Beruflich Dokumente
Kultur Dokumente
VH
HH
8
RF IN SAT-IF OUT OUT IN
7
IN SAT-IF OUT
6
IN SAT-IF OUT
5
IN SAT-IF OUT
4
IN SAT-IF OUT
3
IN SAT-IF OUT
2
IN SAT-IF OUT
1
SAT-IF OUT
BTA30
Adjust OUT
BTC12
CH1 Adjust CH2
BTC12
CH1 Adjust CH2
BTC12
CH1 Adjust CH2
BTC12
CH1 Adjust CH2
BTC12
CH1 Adjust CH2
BTC12
CH1 Adjust CH2
BTC12
CH1 Adjust CH2
BTC12
CH1 Adjust CH2
PS-BTC
Converted SAT-IF IN
Converted SAT-IF IN
Converted SAT-IF IN
Converted SAT-IF IN
Converted SAT-IF IN
Converted SAT-IF IN
Converted SAT-IF IN
Converted SAT-IF IN
Converted SAT-IF IN
IN
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
1536 1577
2089
1998 2038
1918 1958
1798 1878
1705 1758
1286 1369
1120 1162
Signal
0.5dB
EDFA
29.8dB
C/N 54.0 dB
Pin -13.3dBm C/N 49.54dB C/N Fiber 87.8dB @ 862MHz C/N total 48.16dB Output level 74.7dBV
OPTICAL AMPLIFIER
FOR
1550
NM
Application 4 Amplification of 1550 nm optical signals on single mode fibers 4 Video overlay in FTTH networks 4 CATV networks Features 4 Output powers of 16 x 16,5 dBm and 16 x 20 dBm 4 Cladding-pumped ErYb-doped fiber amplifier technology 4 Constant output power control 4 Input and output monitors 4 Dual, hot-plug-in power supply modules for 100 240 VAC or 36 72 VDC 4 Ethernet - Web and -SNMP Interface (a-Version) 4 RS232/RS485 control interface (b-Version) 4 LC display 4 General purpose I/O interface for remote functions 4 LED status indication 4 Very thin design, only 1 HU 4 OEM versions available
Technical Data
General Input signal wavelength Optical output power Wavelength of pump lasers (typ.) Optical return loss Min. optical input level Max. optical input level Polarization dependent gain Noise figure (@Pin=0dBm, =1550nm) Optical isolation @ input Optical isolation @ output [nm] [dBm] [nm] [dB] [dBm] [dBm] [dB] [dB] [dB] [dB] 1545 - 1565 16 x 16,5 0.5 16 x 20 0.5 < 1000 nm >45 -5 +10 0.5 <5.5 35 35
BaalFTTx Series
1
Fx-OV16xxx
FTTx
F X- OV 1 6 x x x
FTTX
Electrical and Mechanical Properties Optical connector input Optical connector output Optical fiber Power consumption Climatic specification Operation Storage EMI Power supply Dual redundant, hot pluggable Enclosure E2000 or SC/APC LC/APC or SC/APC standard singlemode 9/125 m < 45 W ETS 300 019, class 3.1 ETS 300 019, class 1.2 EN50083-2 (April 1996) EN50083-2 /A1 (February 1998) 100 240 VAC or 36 72 VDC 19 / 1 RU
Fx-OV16xxx
BaalFTTx Series
TRANSPONDER AMPLIFIER MODULE Application The BTA30 Module amplifies the SAT-IF signal and combines it with the CATV signal. Combines the two SAT-IF signals from two BTC chassis. Features Two SAT-IF inputs to multiplex two SAT-IF input signals. A separate CATV input to combine CATV and SAT-IF.
General Technical Data Input/output connectors Number of inputs DC pass for LNB Input frequency SAT-IF Input level SAT-IF Gain 2dB Input frequency CATV Insertion loss CATV CATV Signal rejection (SAT-IF input) Output frequency (CATV + SAT-IF) [mA] [MHz] [dBV] [dB] [MHz] [dB] [dB] [MHz] F 2 inputs for SAT-IF + 1 input for CATV max. 500 @ 17V 9502300 59
15862 <2 36 (15862MHz) 152300 125 @ 2150MHz 20 272 x 166 x 45 1,2 050
Output level DIN 45004B (IM3 -35dB) [dBV] Output level regulation Outer dimensions Weight Operating temerature [dB] [mm] [kg] [C]
Fiber.xSAT Series
1
BTA30
FTTx
BTA30
SATELLITE TRANSPONDER CONVERTER MODULE Application Satellite Transponder Converter with programmable transponder conversion for usage in a single cable head end. Converters two analog or digital transponders from one or two independent inputs. Features Built-in AGC for a constant output level. Adjustable output power. Input signal forwarding
General Technical Data Number of inputs Module capacity Input/output connectors Input frequency Input level Troughput loss Return loss DC pass for LNB Output bandwidth Phase noise (F. in 950MHz, F. out 2150MHz) Output frequency Output level Output level regulation Output frequency stability Level stability (25C 20C) AGC Selectivity Outer dimensions Weight Operating temerature [mm] [kg] [C] [MHz] [dBV] [dB] [dB] [mA] [MHz]
BTC22 2 independent
[dBc/Hz] -75 @ 10 kHz [MHz] [dBV] [dB] [MHz] [dB] [dB] 9502150 >78 20 0,15 2 >40
Fiber.xSAT Series
BTCn2
<1,5
FTTx
BTCn2
Passive FTTH Network Termination Box with Optional Optical CATV/SATTV Receiver Module
Application The FWO is a universal wall outlet for termination of in-house fiber optic cabling. It provides a comprehensive solution for the fiber deployment in MDUs including: the passive fiber termination for up to 8 fibers the active termination of optical CATV/SAT-TV signals in combination with the BKtel Optical Compact Receiver OCR (optional) an optical path through port in order to connect GPON/GEPON or EPTP FTTH customer premises equipment (optional)
Features 4 Fiber termination box for up to 8 low bending loss fibers (G.657A). 4 Universal splice holders for heat shrink splices or crimp splices included (8, 4 with installed Receiver Module). 4 Up to 4 Simplex SC adaptors or 4 Duplex LC adaptors on front for passive fiber termination. 4 Carrier for BKtel Optical Compact Receiver (OCR). 4 If the OCR module is installed, up to 2 Simplex SC adaptors or 2 Duplex LC adaptors can additionally be installed 4 Possibility to lock and seal the housing with a supplied screw and seal 4 Bottom /top/rear access for fiber break out cables
BKtel communications GmbH www.bktel.com Email: sales@bktel.com
1
All Rights Reserved FWO BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com BaalFTTx Series All Rights Reserved BKtel communications GmbH www.bktel.com e-Mail: sales@bktel.com
FTTx
FWO
Applications
FTTx
Specifications Physical and Environmental Dimensions (height, depth, width) Optical connector Optical Receiver Kit Optical receiver modules Optical connector CATV/SAT-TV interface Power Supply Power supply interface (DC IN)
All rights reserved. Specifications and availability subject to change without notice - DBe_FWO_101214
35 mm x 80 mm x 140 mm SC or LC
OCR1016E, OCR2209E, OCR1016E-WDM and OCR2209EWDM, for detailed specifications please contact BKtel SC/APC F-female, 75 Plugin Power Supply Unit 6V/2A 2.1/5.5mm connector
O C R 2 2 0 9 E -W D M
COMPACT
OPTICAL RECEIVER
MODULE
DEMULTIPLEXER
Application 4 Receiver module for optical networks with CATV and SAT IF signal distribution, HFC and FTTx nodes Features 4 Ultra low noise push-pull technology 4 Bandwidth of 2.4 GHz 4 46 dB CNR (typ.) for NTSC with OMI = 4% at 8 dBm optical input power @ 1550 nm 4 20 dBmV RF output level (-5 dBm, 1550 nm, OMI = 4%) 4 Very low intermodulations 4 Low power consumption 4 Small package with single-mode fiber pigtail 4 Integrated optical demultiplexer (WDM filter) for RF overlay applications 4 Monitor voltage output and output disable input 4 Status LEDs for input power ok and output enabled Technical Data
Electrical/Optical Characteristics Parameter Optical Input Power Opt. Wavelength for Receiver Opt. Wavelength for IP port Opt. Wavelength for COM port Opt. Insertion Loss COM-IP Opt. Isolation IP1/2 at Receiver Opt. Isolation CATV at IP port Optical Return Loss Power Supply Voltage Power Supply Current Monitor Voltage Fiber Opt. Connector RF-Connector *) Specifications are without fiber connectors COM (CATVin & IPin/out) IP in/out Symbol PIN CATV IP1 IP2 CATV, IP1/2 ATTCOM-IP ISLCATV ISLIP ORL Vcc ICC UCRXPO Min -10 1539 1260 1480 1550 1310 1490 Typ Max 0 1565 1360 1500 0.8 *) 35 *) 20 *) 35 45 5/6 180 Iphoto * 1000 standard single-mode fiber G652 or low bending fiber G657A SC/APC or LC/APC SC/PC or SC/APC or LC/PC or LC/APC F (female) 200 Unit dBm nm nm nm dB dB dB dB V mA V OCR2209E-WDM
IP
WDM
COM
Re ceiver
5 4 3 1
BaalFTTx Series
1
OCR2209E-WDM
FTTx
RF Characteristics
FTTX
Parameter RF Bandwidth Receiver Noise Current RF Impedance RF Return Loss CATV (47-862 MHz) RF Return Loss SAT IF (> 950 MHz) Flatness Output Isolation (output disabled) RF Output Level *) CSO for Cenelec 42 **) CTB for Cenelec 42 **)
Symbol B IENC Z
Min 47
Typ 6
14 @ 47 MHz, -1 dB/oct. 6
75
-2.5 40
+2.5
dB dB
L CSO CTB
22
dBmV dB dB
*) PIN= -5 dBm, 1550 nm, OMI = 4%, RF level decreases with 2:1 law with optical input power **) CSO/CTB contribution of OCR for Cenelec 42 signal according IEC 60728-3 / EN 50083-3, OMI = 4.1%, 1550 nm
Absolute Maximum Ratings Parameter Operating Temperature Range Storage Temperature Range Optical Input Power Power Supply Voltage Symbol TOP Tstg PIN VCC 4.5 Min -10 -40 Max +60 +85 0 6 Unit C C dBm VDC
OCR2209E-WDM
CATV Disable The CATV disable pin 5 allows to deactivate the RF output by a 0-0.8V logic signal level; a 10 kOhms pull-up to VCC is internally connected to this pin (low=deactivated).
Diagnostic LEDs Normal Operation Optical Input Power low CATV Disabled CATV Enabled Mechanical Outlines Optical Input Power LED: lightening green Optical Input Power LED: off Power LED: off
Specifications subject to change without notice - DBe_OCR2209E-WDM_20091209.doc
BaalFTTx Series
2
Connector Pin Description Pin No. 1 2 3 4 5 Description VCC N.C. GND UCRXPO Output Disable Power Supply not connected GND Received optical power: The measured monitor voltage is the product of photodiode current and 1000 10 kOhms pull-up to VCC, CATV signal disabled, if connected to GND
BaalFTTx Series
3
OCR2209E-WDM
FTTx
FOR
Power Supply for usage in BTC-chassis. Features Powers up to 9 BTC modules in one BTC Chassis.
General Technical Data Output voltage 5% Output current 90W Max. absolute current per output Max. total output power Outer dimensions Weight Operating temerature [Vdc] [A] [A] [W] [mm] [kg] [C] 30 0,016 0,15 106 272 x 166 x 45 24 0,4 1,3 17 0,3 0,4 12 2,9 3,8 5 7,9 9,6
050
Fiber.xSAT Series
1
PS-BTC
1,6
FTTx
PS-BTC
FREQUENCY
STACKER
4 Stacking of 2 L-Band signals (950-2150 MHz) in the frequency range from 950- 3750 MHz 4 Usage as headend for optical transmission system of Satellite-IF signals (BKtel Fiber.2SAT) Features 4 Upconversion of one L-Band (950-2150 MHz) into the frequency range from 2550 3750 MHz and multiplexing with second L-band signal in the baseband (950-2150 MHz)
50 1 (N-type ) Typ. 10 -28 (per transponder), -10 (64 transponders) 29 3 Min. 19 Typ. -26 323 Total input power level
950-2150MHz or 25503750MHz
BaalFTTx Series
1
2SAT-S
FTTx
2 S A T- S
L.O. Frequency
FTTX
Synthesiser with external 25MHz XCO 0 to 50C temperature range Integrated from 1kHz to 10MHz Or ASTRA IF-IF Converters Spec
LO Frequency Accuracy
LO Phase Noise
TBD 20
Below ALC threshold and at min. manual attenuator loss Internal 6V DC-DC converter. It is possible to use external power supply from 12V to 21V For 20V power supply
Current Consumption EMC Climatic Specification- Operation Climatic Specification- Storage Dimensions (w x h x d)
mA
<300 EN50083-2
[C] [C] mm
Ordering Information
For more information on this product please contact BKtel communications.
2SAT-S
BaalFTTx Series
FOR
CATV
AND
SAT IF TRANSMISSION
Application
4 Electrical to optical conversion of multichannel CATV signals like AM-VSB, FM, QAM, DTT, DVB-T and DAB signals 4 Electrical to optical conversion of SAT IF video signals like QPSK, 8-PSK and 16QAM by separate input 4 Optical amplification in order to realize several optical outputs to drive FTTx and/or HFC networks 4 Video overlay with 1550 nm wavelength in FTTx networks providing very high optical budget (GPON compatible)
Features 4 Bandwidth of 5870 MHz for CATV and 9502610 MHz for SAT-IF input 4 All-electronically adjustments for CATV input: slope, gain, output power, OMI, pre-chirping etc. 4 Automatic load control (ALC) for constant OMItotrms of CATV signals 4 Separate RF input for SAT-IF signals
4 SBS suppression and prechirping technology 4 Cladding-pumped ErYd-doped fiber amplification technology with constant output power control 4 Optical output port monitor 4 Dual, hot-plug-in power supply modules for 100240 VAC or 3660 VDC 4 Web and SNMP interface 4 LC display and LED status indication 4 General purpose I/O interface for remote functions 4 Very thin, only 1 U design for mounting into 19, ETSI or JIS racks
BaalFTTx Series
1
Fx-AOT08200, Fx-AOT16200
FTTx
Fx-AOT08200, Fx-AOT16200
Block Diagram
Fx-AOT08200, Fx-AOT16200
FTTX
1550 1560 +20 0.5 dB 0.5 dB > 30 35 > 40 +21 for 10 km fiber length +19 for 20 km fiber length F-female, 75, front side mounted LC/APC, front side mounted Standard single mode 9/125 m RJ45, rear side mounted RJ45, rear side mounted Mini, rear side mounted ETS 300 019, class 3.1 ETS 300 019, class 1.2 EN 50083-2 EN 60950, Laser class 1M according IEC 60825-1 (eyesafe for normal viewing) 100 ... 240 VAC or 3660 VDC (dual redundant, hot pluggable) < 65 W power consumption 19 / 1 rack unit [RU] (optionally compatible to ETSI or JIS standards)
RF-connectors/ impedance
Optical connectors Optical fibre Control interfaces Ethernet 10/100 Mbps BKtel RS485 bus I/O ports Climatic specification Operation Storage EMI Safety Power supply Enlosure dimensions Weight [kg]
BaalFTTx Series
Frequency range Frequency response at 80 dBV / 5% 5 7 MHz 7 47 MHz 47 606 MHz 606 870 MHz Return loss 5 47 MHz 47 870 MHz Input level (referred to OMI = 5%) Gain adjustment range
5 870 1.5 0.75 0.5 0.75 18 20 (at 47 MHz) 1.5 dB/oct., min. 15 73 minimum 0 24 -3 (cable equivalent) +16 (cable equalization) 20 > 46 > 45 > 60 4) > 56 4) > 63 > 58 5) > 52 5)
Slope adjustment range (10870 MHz) [dB] Testpoint attenuation CNR ) 47 600 MHz 600 862 MHz CSO 1,2) 47 600 MHz 600 862 MHz CTB 1,2)
1,2,3
Test Conditions
1
) ) ) ) )
Popt,in= -6 dBm, appropriate receiver technology with Ieq= 4 pA/Hz and = 0.95 A/W (at 1550 nm) used, CATV and SAT-IF signals transmitted together (see also test condition 4 below) C42 channel allocation with OMI= 3.9% measured with 5 MHz noise bandwidth 36 SAT-IF carriers with OMISAT= 1.0% for SAT-IF carriers, measured with 27 MHz noise bandwidth Internal prechirping parameter fiber length compensation set according to connected optical fibre length Internal prechirping parameter fiber length compensation set to 7 km, actual fiber length between 0 12 km
2 3 4 5
Available Types
Fx-AOT08200 Fx-AOT16200 Amplified optical transmitter with 8 ports of 20.0 dBm optical output power each Amplified optical transmitter with 16 ports of 20.0 dBm optical output power each
BaalFTTx Series
3
Fx-AOT08200, Fx-AOT16200
FTTx
[]
75
OPTICAL CATV
AND
SAT-IF TRANSMITTER
Application
4 Electrical to optical conversion of multichannel CATV signals like AM-VSB, FM and QAM signals 4 Electrical to optical conversion of SAT-IF video signals by separate input 4 The 1550nm versions enable the usage of optical amplifiers (EDFAs) as boosters or repeaters in order to realize FTTx HFC networks
Features 4 SBS suppression with very high SBS threshold and 1550 nm pre-chirping technology
4 All-electronically adjustments for CATV input: slope, gain, output power, OMI, pre-chirping etc. 4 Automatic load control (ALC) for constant OMItotrms of CATV signals 4 Linearity optimized versions either for European Cenelec 42 or for Japanese NTSC74 channel allocation 4 Separate RF input for SAT-IF signals 4 ITU-Grid wavelength, wavelength adjustable 100 GHz 4 Front panel RF test point 20 dB 4 Dual, hot-plug-in power supply modules for 100240 VAC or 3672 VDC 4 Web and SNMP Interface 4 LC display and LED status indication 4 General purpose I/O interface for remote functions 4 Very thin, only 1 U design for mounting into 19, ETSI or JIS racks
BaalFTTx Series
1
Fx-DS26
4 Bandwidth of 5870 MHz for CATV and 9502610 MHz for SAT-IF input
FTTx
Fx-DS26
Block Diagram
FTTX
SATIN BCIN
20dB
OUT TP
RMS
NEC-E
P
DC AC/DC
Power in
DS26 Fx-DS26
DC AC/DC
[GHz] [dBm]
Fx-DS26
Relative intensity noise (optical return loss > 40 dB) SBS suppression 1) 3) 4) (measured for 25 km fiber length and NTSC74 or Cenelec42 input) Opt. connector Optical fibre
BaalFTTx Series
RF-connector/ impedance Control interface Climatic specification Operation Storage EMI Safety Power supply Dual redundant, hot pluggable Power consumption 110 VAC 48 VDC Enlosure dimensions Weight
Frequency range Frequency response at 80 dBV / 5% 5 7 MHz 7 47 MHz 47 606 MHz 606 870 MHz Return loss 5 47 MHz 47 870 MHz Input level (referred to OMI = 5%) Gain adjustment range
5 870 1.5 0.75 0.5 0.75 18 20 (at 47 MHz) 1.5 dB/oct., min. 15 73 minimum 0 24 -3 (cable equivalent) +16 (cable equalization) 20 1310 -nnn-C42 51 3) 50 3) 65 3) 64 3) 1310 -nnn-N74 51 4) 50 4) 65 4) 64 4) 1550/DWmm -70-C42 50.5 3) 49 3) 53 2)3) (f<600 MHz: 58) 62 3) 1550/DWmm -70-N74 50.5 4) 49 4) 58 2)4) 62 4)
Slope adjustment range (10870 MHz) [dB] Testpoint attenuation Version CNR 1) 0 15 km fibre length 15 25 km fibre length CSO 1) CTB 1) [dB] Fx-DS26-
Test Conditions
1
) Popt,in= 0 dBm, appropriate receiver technology with Ieq= 7.0 pA/Hz and = 0.95 A/W (at 1550 nm) used, CATV and SAT-IF signals transmitted together (see also test conditions 5 and 6 below) ) Internal prechirping parameter flc set according to connected fibre length: 010km / flc=5km, 515km / flc=10km, 1020km / flc=15km, 1525km / flc=20km
3 4 5
) European Cenelec 42 channel allocation with OMI= 4.1% measured with noise bandwidth of 5 MHz ) Japanese NTSC74 channel allocation with OMI= 3.3% measured with noise bandwidth of 4 MHz ) 10 dB backoff of SAT-IF carriers refered to CATV video carriers, 36 QPSK modulated SAT-IF carriers with 27 MHz IF bandwidth, OMISAT= 1.3% for SAT-IF carriers, Cenelec42 carriers with OMI= 4.1%, 27 MHz noise bandwidth ) 10 dB backoff of SAT-IF carriers refered to CATV video carriers, 36 QPSK modulated SAT-IF carriers with 27 MHz IF bandwidth, OMISAT= 1.0% for SAT-IF carriers, NTSC74 carriers with OMI= 3.3%, 27 MHz noise bandwidth
BaalFTTx Series
3
Fx-DS26
FTTx
[]
75
Ordering Information
FTTX
For more information on this product please contact BKtel communications. Properties for ordering optical transmitter Fx-DS26:
70 80 110 130 C42 N74 0 1 1310 1550 DWmm 1 2 3 4 5 F R 0 OEM 230/230 48/48 230 48 230/48
+7.0 dBm +8.0 dBm +11.0 dBm +13.0 dBm Cenelec 42 NTSC 74 No Yes 1310 nm 1550 nm DDM ITU grid no. mm E2000 SC/APC FC/APC-NTT FC/APC-JDS SC/APC with shutter on front side on rear side BKtel OEM 2 x (100240 VAC) 2 x (3672 VDC) 1 x (100240 VDC) 1 x (3672VDC) mixed 230 VAC / 48 VDC
Frequency plan *)
I/O ports
Wavelength
Optical connector
Version
Fx-DS26
Power supply
BaalFTTx Series
Available Types
Fx-DS26-1310-80-C42, Fx-DS26-1310-110-C42 and Fx-DS26-1310-130-C42 Fx-DS26-1310-80-N74, Fx-DS26-1310-110-N74 and Fx-DS26-1310-130-N74 Fx-DS26-1550-70-C42 and Fx-DS26-1550-70-N74 Fx-DS26-DWmm-70-C42 and Fx-DS26-DWmm-70-N74 with mm=21, 23, 45
OPTICAL TRANSMITTER
Application
4 Electrical to optical conversion of SAT-IF and multichannel CATV signals like AM-VSB, FM and QAM signals 4 Enables the usage of optical amplifiers (EDFAs, YEDFAs) as boosters or repeaters in order to realize FTTx networks
4 Automatic load control (ALC) for constant OMItotrms 4 Front panel RF test points 20 dB 4 Dual, hot-plug-in power supply modules for 100240 VAC or 3060 VDC 4 Web and SNMP Interface 4 LC display and LED status indication 4 General purpose I/O interface for remote functions 4 Very thin, only 1 U design for mounting into 19, ETSI or JIS racks
BaalFTTx Series
1
Fx-DS40
4 All-electronically adjustments of gain, output power and optical modulation index (OMI)
FTTx
Fx-DS40
FTTX
Wavelength
[nm]
Type 1550 :
1540 1560nm
Type DWmm : according to ITU grid, CH35...CH48 Optical output power Side mode suppression Opt. connector Input impedance Frequency range Frequency response Return loss Input level Optical fibre RF-connector/ impedance [] [MHz] [dB] [dB] [dBm] [dBm] [dB] 8 1 > 30 Any type of high return loss connector 50 SAT-IF: 9503750 MHz CATV: 5...870 MHz 2 6 -10 8 Standard single mode 9/125 m CATV: F-female, 75 front or rear side mounted CATV test point: F-female, 75 front side mounted SAT: N-type, 50 rear side mounted SAT test point: SMA, 50 front side mounted Control interface Climatic specification Operation Storage EMI Safety Power supply Dual redundant, hot pluggable Ethernet 10/100 interface ETS 300 019, class 3.1 ETS 300 019, class 1.2 EN50083-2, EN50083-2 /A1 EN 50083-1 and EN 60950, Laser class 1M according IEC 60825-1 (eyesafe for normal viewing) 100 ... 240 VAC, or 36 ... 72 VDC < 25/34 VA (1/2 power supplies) < 21/25 W (1/2 power supplies) 19 / 1 rack unit [U] (optionally compatible to ETSI or JIS standards) [kg] 9 (including two power supplies)
Fx-DS40
Available Types
Fx-DS40-1550-80 Fx-DS40-DWmm-80, mm=35, 36, 48
BaalFTTx Series
Application 4 Optical receiver and frequency destacking module for stacked Satellite-TV-signals in BKtel Fiber.2SAT optical transmission system ( to be used with 2SATS dual L-band frequency stacker unit) 4 Usage as optical receiver unit for Satellite-TV video overlay in FTTH networks Features 4 O/E conversion and frequency destacking of multiplexed SAT IF signals 4 Suitable for 2 stacked L-band signals (950-2150 MHz each) 4 2x4 multiswitch included 4 Reception of terrestrial TV (analog terrestrial (TV and Radio), DVB-C, DVB-T (DTT) or DAB signals
Technical Data
Optical and RF Characteristics Parameter Input Optical Wavelength Input Optical Power Optical Return Loss Input RF Frequency Range Total Input RF Power Input RF Power Noise Figure Output Frequency Range SAT-IF Output Frequency Range Trerrestrial Max Gain AGC Range AGC Threshold Nominal Output Power Gain Ripple and Variation OIP3 Isolation 9 26 32 -37 30 -56 -34 -31 6 950 47 40 Min 1310 -18 20 47 -56 -74 3750 -26 -44 4 2150 854 Typ Max 1550 -3 Unit nm dBm dB MHz dBm dBm dB MHz MHz dB dB dBm dBm dB dBm Total input RF power Average per transponder At 950-2150 output frequency band Below AGC threshold Unwanted path to selected path Below AGC threshold Terrestrial 47-854, SAT-IF 950-3750 Total of 64 transponders Per transponder After photodiode @ max gain SAT-IF-IN (H) or SAT-IF-IN (V)
BaalFTTx Series
1
XON80.2SAT-MT
FTTx
X O N 8 0 . 2 S A T- M T
FTTX
Parameter In Band Spurious Out of Band Spurious Output Impedance LO Frequency LO Frequency Accuracy LO Phase Noise
Min 25
Typ
Max
Unit dBc
0 to 50C temperature range Integrated from 1kHz to 10MHz or ASTRA IF-IF Converters Spec
General Technical Data Parameter Operating Temperature Range Storage Temperature Range Power Supply Voltage Current Consumption Select SAT-IF-IN (V) Select SAT-IF-IN (H) Optical Connector RF Output Connectors 15 Min -10 -40 20 140 13 18 SC/APC 5x F-female 165x 155 x 30 mm XON80.2SAT-MT 14 Typ Max +60 +85 Unit C C V mA V V For 20V power supply Not converted path selected Converted path selected
XON80.2SAT-MT
Dimensions
BaalFTTx Series
Application 4 Optical receiver and frequency destacking module for stacked Satellite-TV-signals in BKtel Fiber.2SAT optical transmission system ( to be used with 2SATS dual L-band frequency stacker unit) 4 Usage as optical receiver unit in PON-FTTH networks (GPON and GEPON) with Satellite-TV RF video overlay Features 4 O/E conversion and frequency destacking of multiplexed SAT IF signals 4 Suitable for 2 stacked L-band signals (950-2150 MHz each) 4 2x4 multiswitch included 4 Reception of terrestrial TV (analog terrestrial (TV and Radio), DVB-C, DVB-T (DTT) or DAB signals 4 Integrated WDM module: 1 common optical in/out port (2SAT video overlay + PON Data ), 1 optical in/out port PON Data Technical Data
Optical and RF Characteristics Parameter Input Optical Wavelength Input Optical Power Optical Return Loss Input RF Frequency Range Total Input RF Power Input RF Power Noise Figure Output Frequency Range SAT-IF Output Frequency Range Trerrestrial Max Gain AGC Range AGC Threshold Nominal Output Power Gain Ripple and Variation OIP3 Isolation 9 26 32 -37 30 -56 -34 -31 6 950 47 40 Min 1310 -18 20 47 -56 -74 3750 -26 -44 4 2150 854 Typ Max 1550 -3 Unit nm dBm dB MHz dBm dBm dB MHz MHz dB dB dBm dBm dB dBm Total input RF power Average per transponder At 950-2150 output frequency band Below AGC threshold Unwanted path to selected path Below AGC threshold Terrestrial 47-854, SAT-IF 950-3750 Total of 64 transponders Per transponder After photodiode @ max gain SAT-IF-IN (H) or SAT-IF-IN (V)
BaalFTTx Series
1
XON80.2SAT-MT-WDM
FTTx
X O N 8 0 . 2 S A T- M T- W D M
FTTX
Parameter In Band Spurious Out of Band Spurious Output Impedance LO Frequency LO Frequency Accuracy LO Phase Noise Technical Data WDM Operating Wavelength Pass Band Operating Wavelength Reflect Band Optical Connector
Min 25
Typ
Max
Unit dBc
0 to 50C temperature range Integrated from 1kHz to 10MHz or ASTRA IF-IF Converters Spec
15391565 nm XON80.2SAT-WDM-xPON 15401549 nm XON80.2SAT-WDM-xPON&CATV PON Data in PON Data out 2SAT, PON in/out PON in/out 12601360 nm 14801500 nm SC/APC SC/APC < 0.8 dB > 35 dB > 35 dB > 15 dB
Specifications subject to change without notice - DBe-XON80 2SAT-MT-WDM_20110812
XON80.2SAT-MT-WDM
Insertion Loss Reflect Port (COM PON) Return Loss Isolation Pass Isolation Reflect
General Technical Data Parameter Operating Temperature Range Storage Temperature Range Power Supply Voltage Current Consumption Select SAT-IF-IN (V) Select SAT-IF-IN (H) 15 Min -10 -40 20 140 13 18 SC/APC 5x F-female 165x 155 x 30 mm XON80.2SAT-MT 14 Typ Max +60 +85 Unit C C V mA V V For 20V power supply Not converted path selected Converted path selected
BaalFTTx Series