Sie sind auf Seite 1von 2

The Development of Shamkha South Infrastructure Works Lot 4

Operation/Task: Location/Area: Item Storage and Use of Highly Flammable Liquids South Shamkha Lot 4 Hazards/Risks Identified Fire Explosion Risk Rating
S L RR

Hazard / Impact Risk Assessment


HIRA No: Method Statement Title: Method Statement No: Control Measures Prior to starting work with HFL, quantities will be estimated to ensure that only minimum quantities are ordered. A suitable fire-resistant store will be provided for HFL. The store will be signed according to requirements of the Regulations. HFL will be kept only in suitable containers. For petrol, this will be a marked plastic container of 5 litres maximum capacity. Containers used to store HFL will be marked accordingly to show HFL is present, with a flashpoint of less than 32 degrees Celsius. Lids of containers will be secure. Where HFL vapour is foreseeable, no means of ignition will be present. Areas where HFL is stored or used will be kept clear of combustible material as far as practicable. Spillages will be mopped up immediately and materials removed to a safe place. HFL will not be used for purposes which are unauthorised, such as starting fires. Management will ensure that storage facilities are adequate and are maintained to the specified standard. During inspections, they will check to ensure HFL is being used properly, that spillages are cleared up promptly and that the correct fire precautions are being taken. 09

Activity Storage and Use of Highly Flammable Liquids

Residual Risk
S L RR

Responsibility Operator Operator

4 5

4 4

16 20

4 5

1 1

4 5

Monitoring Responsibility Supervisor Supervisor

SBD SMS SMSP09/F02 Issue No: 01

Revision: Date Issued: Page No:

02 Nov 10 1 of 2

The Development of Shamkha South Infrastructure Works Lot 4


Operation/Task: Location/Area: Item Storage and Use of Highly Flammable Liquids South Shamkha Lot 4 Hazards/Risks Identified Risk Rating
S L RR

Hazard / Impact Risk Assessment


HIRA No: Method Statement Title: Method Statement No: Control Measures Operatives using HFL will be given training. This will include the use of fire extinguishers. 09

Activity Storage and Use of Highly Flammable Liquids

Residual Risk
S L RR

Responsibility Supervisor

Monitoring Responsibility PM

20

KEY:

S = Severity Rating 1. Negligible 2. Minor Injury / Minor Spill / Leak 3. Major Injury (RIDDOR) / Major Spill / Contamination 4. Fatality / Serious Hazardous Release 5. Multiple Fatality / Multiple Catastrophe

L = Likelihood of Occurrence 1. Improbable 2. Remote 1 10% 3. Possible 10 50% 4. Probable 50 90% 5. Almost certain 90%+

5 4 3 2 1

5 4 3 2 1 1

RR = Risk Rating 10 15 20 8 12 16 6 9 12 4 6 8 2 3 4 2 3 4 Likelihood

25 20 15 10 5 5

R O Y G

Unacceptable risk, plan out or add further controls Acceptable only if no other method viable and with high level controls in place Acceptable with suitable controls Acceptable, no further action required

HIRA Prepared by (Name): HIRA Approved by (Name):

Severity

Signature: Signature:

Date: Date:

SBD SMS SMSP09/F02 Issue No: 01

Revision: Date Issued: Page No:

02 Nov 10 2 of 2