Building intercom system installation and debugging methods

I. Preparation before installation 1 , the system before installing the equipment required to conduct a comprehensive inspection of all lines , whether broken or short circuit ; 2 , make sure the entire system without any fault line only after the installation of equipment, wiring soldering the contacts must be added ; 3 , installation of equipment must be strictly in accordance with the instructions supplied with the product or the installation manual for proper wiring. Second, the system checks before commissioning the power 1 , all equipment installed, must be comprehensive inspection of all parts of the wiring is correct ; if a wrong connection can cause the entire system are not working properly . 2 , in particular, check the power cord is connected correctly , whether a short circuit between positive and negative , or after power lines ranging from burning equipment and related equipment , a serious cause a fire. Third, the cell floor, intercom and visible part of the commissioning 1 line and wiring to ensure correct equipment in good condition in the case , after the power unit system can work . 2 in the cell floor debugging, first and lowest level of protection door host / decoder , and all the wiring to connect the indoor unit is good, while the extension of the room number in accordance with instructions number ; debug this layer of the power system operating conditions Confirm door host and bottom line and whether the device is normal . 3 If the door of the host and the normal job description lines and equipment are normal ; Then power off the system , then connect the system's main line on the floor , the second layer debugging ( the wiring system must be powered off ) , followed by up to . 4 unit building in the debugging process , you must start from the bottom up layer by layer debugging , that after commissioning of the first layer , the second layer further debugging , and so has been up commissioning, until the entire unit debugged and working properly . Under normal circumstances, the voltage by using a multimeter voltage range measuring the following parameters determine the quality of line or equipment ; Static when the power supply voltage and + B -to-ground voltage: 12V Audio line A2 to ground voltage : 0V Data line P -to-ground voltage : 0V Call through extension , the audio line -to-ground voltage will change : rose 5.6V At the same time the moment of call through the extension line of the data line P to a rapidly changing measure pulse voltage varies between 0-5V .

www.ttbvision.com

Das könnte Ihnen auch gefallen