Sie sind auf Seite 1von 8

Site Analyzer Easy-To-Use

Cable And
Antenna Tester

The The Best Best

Portable Portable Cable And Antenna tester For


Wireless Wireless
Site Analyzer
Easy-to-use cable and antenna tester
World-wide applications include Cellular and PCS/DCS systems with AMPS, CDMA, GSM or TDMA modulation schemes. Other applications include 3G, Paging and Trunking Current frequency range is 806 to 2300 MHz Easy operation for first-time, occasional or experienced users Accurate and repeatable measurements Immunity to on-channel interference (+13 dBm) for testing at co-located antenna sites High-resolution color display Fast sweep rate On-screen comparison of live sweep and recalled trace Unlimited trace overlays per report to compare antennas and track performance over time Power meter option compatible with Bird power sensors

Cable And Antenna tester For Professionals Professionals

Identify Small Problems Before They Grow Into Big Headaches


The Site Analyzers advanced design and high resolution color display help you detect minor problems before they become major headaches. Birds instrument easily uncovers faults that elude less sophisticated testers. And the Site Analyzers high directivity and low source match ensure accurate and repeatable Match and Fault Location measurements. Locate long range problems with 238 display points. Pinpoint small problems with 60 dB dynamic range. High resolution marker reports VSWR with the precision of expensive laboratory equipment. Site Analyzer measurements are interchangeable with your existing measurement data. Perform cable insertion loss measurements Include optional power measurement capability

Superior Signal Immunity Lets You Test When Its Convenient


High ambient RF levels can limit the usefulness of other cable and antenna test instruments. Birds advanced Site Analyzer rejects on-channel interfering signals to +13 dBm, so you can test antennas located in active sites. Work when its convenient not just when a site can be powered-down.

Portable Portable Analytical power Analytical power


Helps You Do The Job Right
On-screen Data Comparison No PC Required
Self-contained analytical capabilities let you precisely compare two traces on-screen without using a PC. The Site Analyzer provides a lot more than reliable measurements of Fault Location, Return Loss and VSWR. The bright, color screen highlights key information to help you quickly pot problems. State-of-the-art transflective LCD technology provides crisp visibility in everything from darkened shelters to direct sunlight! Precise markers report VSWR to 0.01 dB. An automatic delta marker compares two traces to reveal any degradation in antenna system performance. A Pass-Fail indicator facilitates quick Go/No Go Testing. Digital signal processing provides trace updates in only 2 seconds. Stores 60 sets of measurement data with a time/date stamp. Built-in parallel printer port for direct printing of professional looking, instant reports. Built-in drivers support popular HP ink jet printers. Serial interface supports data transfer to a PC for additional analysis with our Windows 95/98/NT compatible software. Cable loss mode Power measurement with 5010 Sensor

Helps You Do The Job Right

Display forward and reflected power as well as VSWR and return loss Compatible with Model 5010 Digital Power Sensor Small and lightweight sensor Multi-carrier capable, may be placed at output of transmit combiner or linear power amplifier Accuracy of 5% of reading with 40:1 Dymanic Range Example, 50W element measures from 1.25 to 50W

Fast, Easy Fast, Easy Operation Operation Increases Your Increases Your Profitability Profitability
1 2 Bird designed the Site Analyzer to be exceptionally easy-tooperate. Extensive user beta tests led to numerous refinements. The final product is a portable cable and antenna tester that surpasses all others in testing capability, operating speed and its ability to be mastered by inexperienced technicians. 3 6 5 3

High-impact housing is lightweight, rugged and ergonomically sculpted for comfortable hand-held use. Bright, high resolution color screen accentuates important findings and clearly organizes operating functions and test results. Intuitive soft key, menu operation lets you focus on testing. Four dedicated keys for commonly used functions accelerate testing. Up to 5 calibration profiles are stored in non-volatile memory. Pop-up menus contain over 70 cable types and 30 frequency band presets. Quickly select test parameters without set-up errors. Measurement data is stored in non-volatile memory. Data labeling allows descriptive naming of measurement data. The automatic time-date stamp is another convenient way of organizing measurement results. 7

Advanced Advanced

Battery Battery Technology Technology For Reliable Portable Opera


For Reliable Portable Operation
The new Site AnalyzerTM brings portable operation to unprecedented levels with an advanced power system. A memory-free Li-Ion battery reliably provides 3 hours minimum operating time per charge. No special conditioning or discharge cycling is required. Longer operation is available using an optional external battery pack. Advanced Li-ion battery operates 3+ hours on a single charge. Li-Ion has no memory effects like old fashioned Nicad batteries; no special charge conditioning is required. Battery power pack can be repaired in the field while your data remains safe in nonvolatile memory. Automatic power-down conserves battery life. Charge activity and battery condition are easily viewed on the front panel indicator. Can also be powered with any 9-16 Vdc power supply. An AC Power Supply and Automotive Adapter are included. Optional SA-BATPAK external battery pack is available for users desiring longer operating time than the 3 hours provided by the Site Analyzers internal power supply.

Powerful Analysis Software Creates Professional Reports


The Site Analyzer features built-in analytical and reporting functions, but you can also download measurement data to a PC for additional analysis. Birds user-friendly MS Windows 95/98/NT compatible software does everything from analyzing an unlimited number of traces to using data generated by other cable and antenna testers. Compatibility with existing data generated by the Anritsu Site Master, Bird Site Analyzer and Bird AT-Series Testers. Familiar Windows 95/98/NT interface simplifies data analysis and report generation. Operates with Windows 3.1/95/98 equipped PCs or Windows NT Workstations. Supports long file names for easy data identification. Build historical records with an unlimited number of traces in one document. Intelligent drag-and-drop automatically converts traces to a common scale for precise and reliable comparisons. Automatic cursor calibration maintains accurate readouts of trace data even if the x-axis changes.
Windows is a registered trademark of Microsoft Corporation.

Optional Site Analyzer Accessories For Assembling Custom Test Packages

ation

Precision Calibration Combos Three precision standards combined in one convenient component. Type N and 7/16 DIN available. These all-in-one, T-design devices contain a precision load, open, and short for calibration of the Site Analyzer . A choice of connectors enables these kits to be used at the Site Analyzers test port, or the end of a test cable. Part No.
CAL-MN-A CAL-FN-A CAL-ME-A CAL-FE-A

Connector Adapters These adapters permit you to mate N-type and 7/16 DIN male and female connectors. They are an ideal accessory for use with the TC Series armored, phase-stable test cables. Compensated transition ensures repeatable results. Type N to 7/16 DIN male and female. Part No.
PA-MNME PA-FNME PA-MNFE PA-FNFE

Description
N-type male connectors N-type female connectors 7/16 DIN male connectors 7/16 DIN female connectors

Description
N-type male to 7/16 DIN male N-type female to 7/16 DIN male N-type male to 7/16 DIN female N-type female to 7/16 DIN female

Test Port Extension Cables Phase-stable for reliable, consistent results. Armored shield holds up to field use. TC-Series test cables are available in a variety of lengths and terminations. The male N-type termination connects to the Site Analyzer test port. The other connector is available as male or female N type or 7/16 DIN. Part No.
TC-MNMN-1.5 TC-MNMN-3.0 TC-MNMN-5.0 TC-MNMN-1.5 TC-MNMN-3.0 TC-MNMN-5.0 TC-MNMN-1.5 TC-MNMN-3.0 TC-MNMN-5.0

External Battery Pack Up to 2 hours additional operation. Reliable lead-acid technology. The SA-BATPAK External Battery Pack delivers up to two hours of additional operating time. A case, shoulder strap, belt clip, and charge adapter are included.

Length, Connectors
1.5 meters. Male N + Male N 3 meters. Male N + Male N 5 meters. Male N + Male N 1.5 meters. Male N + Female N 3 meters. Male N + Female N 5 meters. Male N + Female N 1.5 meters. Male N + Female 7/16 DIN 3 meters. Male N + Female 7/16 DIN 5 meters. Male N + Female 7/16 DIN

Transit Case The Model 7002B870 Transit Case affords maximum protection for the Site Analyzer and accessory items during field use or shipment of the unit. Durable hardshell, polyethylene molded construction with metal frame and latches.

Model 5010 Digital Power Sensor and DPM Elements Display forward and reflected power as well as VSWR and return loss Small and lightweighted sensor Multi-carrier capable, may be placed at output of transmit combiner or linear power amplifier Accuracy of 5% of reading with 40:1 Dymanic Range Example, 50W element measures from 1.25 to 50W

SPECIFICATIONS

SITE ANALYZERAND STANDARD ACCESSORIES


FREQUENCY CHARACTERISTICS MODEL SA-2000A
Frequency Range: Trace Resolution: 806 - 2300 MHz 238 data points

MEASUREMENT CHARACTERISTICS
Return Loss: Test Port: Impedance: Speed: Immunity to Interfering Signals: Maximum Input Signal: 0 to -60 dB N-type female connector 50 1 multi-frequency scan/2 seconds Rejects on-channel signals up to +13 dBm. +22 dBm

PERIPHERAL PORTS
Data transfer: Printer: 9-pin RS-232 (DB9), compatible with PC serial port. Selectable baud, parity, and handshake. 25-pin (DB25) parallel. Built-in drivers for popular HP-type ink jet printers.

POWER
Internal: Rechargeable (fast charge) Li-Ion batteries. 3 hour minimum operating time. Auto shut-off conserves battery life. 9 to 16 Vdc, fused 100 to 240 Vac, 50-60 Hz

External DC: External AC:

ENVIRONMENTAL
Operating Temperature: Storage Temperature: Humidity: Altitude: -10 to 50 C (14 to 122 F) -40 to 80 C (-40 to 176 F) 95% 5% max., (non-condensing) Up to 15,000 feet (4572 m)

FORM FACTOR
Dimensions: Weight: 10-1/2" x 8-1/2" x 3-1/4" (267 x 216 x 83 mm) 4-1/2 lb (2 kg)

STANDARD ACCESSORIES
The Site Analyzer includes Carrying Case, Instruction Manual, Serial Cable, PC Tool Software for Windows, AC Power Supply and Automotive Power Adapter.

Preliminary specifications. Bird reserves the right to change features and specification without notice or obligation. Meter, sensor, and plug-in elements priced separately. * Power and frequency range based on selected plug-in elements. Select FWD and RFL elements with a 10:1 power ratio. Example: Select 50 W FWD element and 5 W RFL element.

Electronic Corporation
A Member of Bird Technologies Group

30303 Aurora Road, Cleveland, OH 44139-2794 Tel: 440-248-1200 Fax: 440-248-5426 Email: sales@bird-electronic.com Website: http://www.bird-electronic.com

2000 Bird Electronic Corporation. 871-SAT026-0900