1 GENERAL DESCRIPTION......................................................................................... 5 1.1 Function ............................................................................................................ 5 1.2 Design ............................................................................................................... 5 1.3 Principle of Operation...................................................................................... 6 1.4 Safety and Monitoring Equipment .................................................................. 7 2 APPENDICES ............................................................................................................ 8 2.1 Designation of Parts ........................................................................................ 8 Drawing .................................................................................... HTCT 319 369 B n

en

HTCT 690 566 Var. 51 B

GTC2

System Description

Blank page

HTCT 690 566 Var. 51 B

en

GTC2

System Description

1 1.1

GENERAL DESCRIPTION Function


The control air supply system supplies the gas turboset with the control air demanded from the air-controlled valves.

1.2

Design
Drawing HTCT 319 369B shows the design in schematic form. The main components are: control air unit with: control air compressor control air tank inlet filter adsorption dryer safety and monitoring equipment MBX35 AA001 MBX35 AP010 and AP020 MBX35 BB010 and BB020 MBX35 AT010 and AT020 MBX35 AT012 and AT022 MBX35 AT011 and AT021

en

HTCT 690 566 Var. 51 B

GTC2

System Description

1.3

Principle of Operation
With the start of the gas turboset, control air supply system MBX35 also starts and remains in operation until the turboset has come to standstill. Normally both compressors, MBX35 AP010 and AP020, are in operation. Compressor MBX35 AP010 supplies air tank MBX35 BB010 and is controlled by pressure switch MBX35 CP010. The air taken in is pumped through filter with water separator MBX35 AT010, dryer AT011 and filter AT012 into air tank MBX35 BB010. Then the cleaned and dried air flows through safety valve MBX35 AA011, air outlet valve MBX35 AA012 and pressure reducer MBX35 DP030 into control air systems MBX36 and MBX37. Compressor MBX35 AP020 supplies air receiver MBX35 BB020 and is controlled by pressure switch MBX35 CP020. The air taken in is pumped through filter with water separator MBX35 AT020, dryer AT021 and filter AT022 into receiver MBX35 BB020. Then the air flows through pressure reducing valve MBX35 AA021, air outlet valve MBX35 AA022 and pressure reducing valve MBX35 DP030 and also into the control air systems. During a failure of one compressor the other one supplies the control air systems with the demanded control air. A faulty compressor can be repaired or replaced during operation. To prevent air from escaping into the open during repair or replacement, the operator has to close the corresponding air outlet valve MBX35 AA012 or MBX35 AA022. After repair has been completed, the operator has to open the air outlet valve. During normal operation, both air outlet valves are open.

HTCT 690 566 Var. 51 B

en

GTC2

System Description

1.4

Safety and Monitoring Equipment


MBX35 AA010 and AA020: Check valve During standstill of the compressors, the valves prevent compressed air from flowing back through the compressors into the open. MBX35 CP001: Measurement of pressure The sensor measures the control air pressure before pressure reducer MBX35 DP030 and initiates an alarm in the control room, when the pressure drops below a preset level. MBX35 CP010 and CP020: Measurement of pressure (switches) Measurement MBX35 CP010 monitors the pressure in tank MBX35 BB010 and controls compressor MBX35 AP010; MBX35 CP020 monitors the pressure in tank MBX35 BB010 and controls compressor MBX35 AP010. When the pressure reaches the preset upper level, the pressure switch shuts off the corresponding compressor. When the pressure drops to the preset lower level, the level switch shuts-off the corresponding compressor. MBX35 CP030: Measurement of pressure The sensor measures the air pressure after pressure reducing valve MBX35 DP030 and indicates it locally. MBX35 DP030: Pressure reducer with pressure gauge The valve reduces the control air pressure to the required operating pressure. MBX35 EG001: Collective alarm enclosure The sensor measures the control air pressure in the control air unit. If the pressure in one of the pressure tanks drops below the lower limit or exceeds the upper limit, an alarm is initiated in the control room. MBX36 CP002: Measurement of pressure The sensor measures the pressure after pressure reducing valve MBX36 DP001 and indicates it locally. MBX36 DP002: Pressure reducing valve with pressure gauge The valve reduces the control air pressure to the preset operating pressure.

Measuring point MBX37 CP001 is provided for commissioning, service and maintenance.

Measuring points are not equipped with instruments.

en

HTCT 690 566 Var. 51 B

GTC2

System Description

2 2.1

APPENDICES Designation of Parts


KKS-No. MBX35 AA001 MBX35 AA010 MBX35 AA011 MBX35 AA012 MBX35 AA020 MBX35 AA021 MBX35 AA022 MBX35 AA030 MBX35 AP010 MBX35 AP020 MBX35 AT010 MBX35 AT011 MBX35 AT012 MBX35 AT020 MBX35 AT021 MBX35 AT022 MBX35 BB010 MBX35 BB020 MBX35 CP001 MBX35 CP010 MBX35 CP020 MBX35 CP030 MBX35 DP030 MBX35 EG001 MBX35 GW001 MBX36 MBX36 AA050 MBX36 CP002 MBX36 DP002 MBX37 MBX37 CP001 Designation Control air unit Check valve Pressure reducing valve Air outlet valve Check valve Pressure reducing valve Air outlet valve Shut-off cock Control air compressor Control air compressor Inlet filter with water separator Adsorption dryer Inlet filter Inlet filter with water separator Adsorption dryer Inlet filter Control air tank 1 Control air tank 2 Control air pressure switch Pressure switch Pressure switch Measurement of control air pressure Pressure reducer with pressure gauge Common alarm control Power supply control air unit Control air to fuel system Solenoid valve to ignition torch Measurement of pressure Pressure reducing valve with pressure gauge Control air supply Measuring point for pressure

HTCT 690 566 Var. 51 B

en

GTC2

System Description

Designation of Connections
(A) (B) (C) (D) To ignition torches, secondary air for ignition To solenoid valves for ignition gas unit To solenoid valves drain valves and blow-off valve To solenoid valves for fuel oil and fuel gas