Sie sind auf Seite 1von 104

commercial air Conditioners 2013

LG Electronics AE Company, Commercial Air Conditioning


20 Yeouido-dong, Yeongdeungpo-gu, Yeouido P.O.Box 335 Seoul, 150-721, Korea.
www.lg.com www.lgeaircon.com
Copyright 2013 LG Electronics. All rights reserved.

Distributed by

Greenovation
Greenovation represents some of LGs core values including reducing greenhouse gas emissions, promoting sustainable growth with suppliers and developing new green businesses.

Green Vision
LGs green vision is to provide values that enhance the quality of life for its consumers and create a healthier and cleaner environment.

co2

Green Goals
LG is committed to creating innovation values that contribute to environmental protection through Greenovation activities.

co2

Green STRATEGY
LG is working towards minimising its environmental impact through the entire production process to deal with various environmental issues, including climate change. To achieve this, LG has established the following five green management strategies:
Respond pro-actively to climate change Strengthen Green energy business Enhance Green product development Promote green and sustainable growth Facilitate resource recycling

GHG
Reduction

co2

Green Management
The Green Technology Committee makes decisions concerning LGs green management strategy. It consists of CTO as the head and executive officers, including a research director. The Green Technology Committee aims to create operational initiative for development of green technologies and products.
co2

CEO
CTO Green Technology Committee Green Strategy Department

Green Materials Technology Exchange

Green Marketing Council

Climate Change Response Committee

Green Businesses
Secure future green growth drivers in energy, water treatment and environmental businesses
Solar Business Lighting Solution Business HVAC Business Water Treatment Business Smart Grids Business

co2

Were in the business of creating comfort for any season in the year through Heating, Ventilation and Air-Conditioning solutions. LG provides a total HVAC system with optimised heating, ventilation and air-conditioning solutions carefully adapted to the unique conditions of each site during the buildings construction or renovation. The company is also engaging in the development of green buildings through its line of products using renewable energy. For example, our MULTI V Water uses geothermal energy, which is known as a constant source of heating and cooling that maintains a temperature of 155C regardless of the surface temperature.
Summer (Cooling)
Cool the air thanks to Multi V Water and a heat exchanger in the ground

Winter (Heating)
Heat the air thanks to Multi V Water and a heat exchanger in the ground
Multi V Water
HVAC HVAC

Cooled air

Heated air

Heat Exchanger

Surface 30 C Underground 15+/-5 C


Heat transfer to the ground

Surface -10 C Underground 15+/-5 C


Heat transfer from the ground

GREENER PRODUCTS
LGs Green Product Strategy aims to minimise the environmental impact at every stage of the product lifecycle and improve the use of energy and resources through the production of highly energy-efficient products, reduced use of raw material, and the improvement of the environment.
co2

GREEN HEATING AND AIR CONDITIONING


LGs heating and air conditioning products are continually being developed with energy savings and the reduction of hazardous substances in mind. In particular, we have made great strides in the use of renewable energies through our cutting edge systems.

Green Product Strategy


Resource Reduction
R  educe product weight / volume Use recycled materials

Awards & Certifications


Hazardous Substances Management
R  educe use of heavy metals Phase out certain hazardous materials
es rc

2010 Green Technology Certification (Inverter and solar technology) - Korea 2010 Energy Winner Award Grand Prix - Korea 2010 GreenGrowth Brand - Korea Carbon Footprint Label - Korea

an um

Recyclability Improvement
U  se recyclable materials D  esign for easy co2 disassembly

Res ou

Green Product

Home Envirment
D  ecrease noise and vibration

Energy

Prize-Winning Technologies
co2

Energy Efficiency Enhancement


Reduce power consumption Reduce stand-by power

CO2 Emission Reduction


Use renewable energy R  educe CO2 emissions through product life-cycle

Energy-saving, High-efficiency Inverter Compressor and Motion Sensor This super energy-saving inverter compressor technology saves up to 72% of electricity by automatically controlling the unit according to the indoor temperature and a motion sensor. High-efficiency Central Air Conditioning System Using eco design for every part of the product has improved the energy efficiency of this air conditioning system. It features the worlds first heat exchanger, providing continuous heating, as well as one of the first high-efficiency, high-pressure inverter compressor. High-performance, High-efficiency Inverter Heat Pump Air Conditioner These compact outdoor units feature enhanced heating and cooling technology, low-noise indoor units and a highly efficient inverter heat pump, with up to 115% cost savings compared to constant-speed air conditioners.

Geothermal Air Conditioner and Heater By using geothermal energy to reduce greenhouse gas emissions, this high-efficiency Standard Inverter technology allows the uninterrupted flow of the magnetic field within the motor of the compressor in the outdoor unit. Hybrid Solar Air Conditioner This product incorporates the energy efficiency enhancement of a power saving inverter as well as allowing for a 100% solar powered air purifier function and a 15% solar powered cooling function. There is also a Human Care Robot, a Green-tea HEPA and Platinoid enzyme filters.

Green Product Evaluation System


The Eco Index The Eco-Index is LGs own rating system for managing environmental performance and goal setting. This quantifies the eco design level of products in terms of their eco-consciousness (Green 1-Star, 2-Star and 3-Star). The Green Index measures three areas of product footprints such as impact on the Climate, as well as the Chemicals and Materials used. We will continue to increase the number of products that achieves the highest Eco-Index. Evaluating the Carbon Footprint of the Product Process Since 2002, LG has been conducting Life Cycle Assessments (LCA) to evaluate its carbon footprint and to fully utilise LCA to develop low carbon products. In 2011, LG built the Life Cycle Inventory Database(LCI DB) for eight product categories(TV, monitors, washing machines, refrigerators, LED, solar modules, mobile phones and commercial air conditioning systems) .

Green R&D Investment


LG established environmental accounting guidelines in 2009 for green R&D investment. LG invested KRW 808 billion in Green R&D in 2010. The majority of the investment was used for improving product energy efficiency and improving resource efficiency.

Green Technologies
LG has been conducting R&D to reduce the environmental impact of products by; developing a range of highly efficient products; replacing hazardous substances in products; improving product design to facilitate recycling; and establishing an infrastructure that enables the development of green products and technologies.

Eco-Innovation
The Rule of 20
LG Electronics air conditioners integrate these expectations from European regulations On Energy-related Products (ErP) requiring manufacturers to produce energy efficient products.

Energy Label
LG products display their energy credentials on the standardised energy label, a transparent and easy to compare tool. The higher the class, the less energy-hungry your product is at delivering heating or cooling.

SEER

SCOP

-20%
primary energy consumption

-20%
greenhouse gas emissions

+20%
Sharing of renewable energy

2020

By the year

A+++ A++ A+ A B

SEER 8.5 6.1 SEER < 8.5 5.6 SEER < 6.1 5.1 SEER < 5.6 4.6 SEER < 5.1 4.1 SEER < 4.6 3.6 SEER < 4.1 3.1 SEER < 3.6 2.6 SEER < 3.1 SEER < 2.6

SCOP 5.1 4.6 SCOP < 5.1 4.0 SCOP < 4.6 3.4 SCOP < 4.0 3.1 SCOP < 3.4 2.8 SCOP < 3.1 2.5 SCOP < 2.8 2.2 SCOP < 2.5 1.9 SCOP < 2.2 SCOP < 1.9

Seasonal Efficiency
Seasonal Efficiency is a new measurement of air conditioning energy efficiency, conducted in various environmental conditions, reflecting real life environments. LG products improve the indoor environment and save energy in a cost efficient way.

C D E F G

Several temperature ratings


To reflect performance over entire season

No longer operations at full load


Integrates operations at partial load

Includes energy consumption in auxiliary modes


Thermostat Off Standby Mode Off Mode Crankcase Heater

* SEER : Seasonal Energy Efficiency Ratio * SCOP : Seasonal Coefficient of Performance

LG Electronics Inc,. participates in the Eurovent Certification Program for Air Conditioners (AC) and Liquid Chilling Packages (LCP) . The certified data of certified models are listed in the Eurovent Directory. MULTI units are Eurovent certified for combinations up to 2 indoor units

OUTDOOR UNITS
38 62 64 66

LG can improve your quality of life


in an affordable, eco-friendly way. Over the years, LG has strived to meet the demand for high quality air conditioning solutions with greater energy efficiency, which can reduce energy costs and also help to protect the environment. Greater energy savings can be achieved over the lifetime of the product which can offer cost savings to your home and business. Furthermore, LGs air conditioners are reliable products with long lifespans designed to provide years of hassle-free performance.

INDOOR UNITS
98 ART COOL 100 Standard 101 Wall Mounted 102 Console 104 Ceiling Cassettes 108 Ceiling Concealed Ducts 114 Fresh Air Intake Units 116 Ceiling & Floor / Ceiling Suspended 118 Floor Standing

HYDRO KIT
126 HYDRO KIT

Eco V
134 ECO V 139 ECO V DX

V-NET & ACCESSORIES


148 Remote Controls 152 Central Controllers 166 Accessories

2013 Outdoor unit line up


Heat pump

Heat Recovery

HP 8, 10, 12

HP 14, 16, 18, 20

HP 22, 24

HP 26, 28

HP 30, 32, 34,


36, 38, 40

HP 42, 44

HP 46, 48, 50, 52,


54, 56, 58, 60

HP 62, 64, 66, 68, 70,


72, 74, 76, 78, 80

1, 220V

3, 380V

4HP

5HP, 6HP

HP 4, 5, 6

HP 4, 5, 6

HP 6, 8

Heat pump

Heat Recovery

HP 8, 10, 16, 18, 20

HP 24, 26, 28, 30, 32, 34, 36, 38, 40

HP 42, 44, 46, 48, 50, 52, 54, 56, 58, 60

10

11

2013 INdoor unit line up


kW

1.5 5k

2.2 7k

2.8 9k

3.6 12k

4.5 15k

5.6 18k

6.2 21k

7.1 24k

8.2 28k

10.6 36k

12.3 42k

14.1 48k

15.8 54k

22.4 76k

28.0 96k

Btu / h

Series

Mirror

Standard Wall mounted Console


4 Way Cassette (570x570)

Ceiling Cassettes

4 Way Cassette (840x840) 2 Way Cassette 1 Way Cassette Low Static

Ceiling Concealed Ducts

Built-in High Static

Fresh Air Intake Units Ceiling & Floor Ceiling Suspended


With Case Without Case

Floor Standing

12

13

offers outstanding energy savings, easy installation and connection to many different types of indoor units, making it easy to design and install.

OUTdoor unit

16 32 34 36

14

Heat pump
Outdoor Unit_MULTI V

New BLDC Inverter Fan Motor

New Optimised Refrigerant Distributor


Standard Deviation of T_out Standard Standard Deviation Deviation of T_outof T_out
6C
6C
COP 18%UP 18%U P

Equipped with a highly efficient BLDC motor. Power consumption has been reduced and output has been improved, compared to the normal induction motors. With strong torque and a powerful Neodymium magnet inside the rotor, the BLDC motor provides a large volume of air and high static pressure.

It distributes refrigerant equally to the heat exchanger for better performance and efficiency.

6C

COP

COP

5 5 5C C C

5 5 5C C C
1C
After

Newly Designed Propeller Fan (Super Aero fan)


Conventional Conventional MULTI V III MULTI V III

5C
1C
After
Before Before

1C
After

The Super Aero fan is a high static pressure fan with large air volume, which produces less noise level than conventional fans.

Standard Standard Deviation Deviation of T_out of T_out

Before

OLD NEW

OLD NEW

OLD NEW

Low noise levels due to pod-shaped design

Minimises vortex resistance with a curved shape

Provides high air volume and high static pressure with the changed shape
Conventional Conventional MULTI MULTI V III V III

6C6C Note : COP COP 1. Capacities are based on the following conditions Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB 5 5 5C C C5C 5 5 C C Interconnecting piping length 7.5m, Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification 1C 1C
Before Before AfterAfter

OLD NEW

6 6

FDD (Fault Detection & Diagnosis)

Cyclone Sub-Cooling Circuit


Sub Cooling circuit
3 4 Liquid 3 Liquid + Gas

The diagnostic system maximises product reliability through the new intelligent algorithm, which has simulations on refrigerant distribution.

The sub-cooled liquid refrigerant helps to prevent oil recovery (performance) degradation which may occur in piping lines.
Sub-cooling circuit control: Extracts part of the refrigerant of the SC circuit equipped in the liquid line exit of an outdoor unit and expands that extracted refrigerant using the SC EEV to make low temperature refrigerant, and then performs heat exchange in the system using that low temperature to increase the sub-cooling rate of the system. New & Improved function
2 P 4 3 2

Condenser

Sub Cooling Circuit

FDD

SC EEV

Comp

Cooling Cycle
4 1

1. Automatic test run 2. Refrigerant amount check 3. Real-time diagnosis (refrigerant and parts) 4. Real-time back-up (compressor and sensors)

EEV
5

Evaporator
1

Capacity H

4 5 7

V-scroll (LG BLDC inverter compressor)

New Oil Management Technology (Hipor)

The new compressor uses LG BLDC motor, produces magnetic torque and generates a strong rotational force, to provide high efficiency at a low noise level. The compressor has a, back pressure structure, whereby pressure is maintained and oil lubricated smoothly. It is one of the most efficient scroll inverter compressors for VRF systems due to its outstanding performance and reliability.

HiPOR is a new technology that maximises the reliability and efficiency of the compressor by reducing pressure loss. This is done by forwarding refrigerant and oil to the higher pressure side using the pump installed inside the compressor.

Motor output 75% improvement. (Power consumption reduction vs. AC motor)

Comp

Oil Separator

Comp

Oil Separator

Rotor

Steel Plates

ND Magnetic

1 2

COP 5% improvement
HiPORTM

Improve oil supply at low torque


Low pressure COMP High pressure O/S Low pressure

COMP High pressure

O/S

2
Oil Supply Mechanism Oil Discharge Reduction High Efficient Oil Pump

Bypass loss
Conventional

No Energy loss
MULTI V III

16

17

100

Peak P Pea k
(%)
50

0 47

Heat pump
Outdoor Unit_MULTI V

(dBA) A 44
41

41dBA

8:00

12:00

4:00

8:00

12:00

4:00

8:00()

High Cooling and Heating Efficiency


High efficiency BLDC V-scroll inverter compressor High efficiency BLDC inverter fan motor High air volume fan Optimal heat exchanger distribution
*BLDC : T h e LG inverter air conditioner comes with a BLDC compressor that uses a strong neodymium magnet. Its compressor thus has improved efficiency compared with the AC inverter.

Night Silent Operation


By using, fan control technology together with real-time outdoor temperature detection, the product has a low-noise operation function that can be used during the night. Night silent operation can be used only in cooling and heating modes or cooling mode only, this is set up by using the dip switch. *9 steps of low-noise operation are possible to provide more quiet operation during the night.
*9 steps (3 steps reductin and 3 different timings)
100

Capacity

Load
0

Sound level

Conventional MULTI V lll


Conventional model

Day
Step 1 Step 2 Step 3

Night

Day

More detailed information, please refer to the PDB

Mode Start

Mode end
12:00 am 4:00 am 8:00 am Time

11%

ON

OFF

ON

OFF

ON

8:00 am

12:00 pm

4:00 pm

8:00 pm

4.58

4.27

25%

Heating of Performance (COP) = Coefficient supply Energy Efficiency Ratio (EER) =

OFF

Heating Energy consumption

OFF

ON OFF

4.12

Continuous Heating Operation *

MULTI V III uses split defrost technology to heat continuously without having to stop indoor units, which provides constant MULTI V lll Time heating when required.

Heating operation Continuous heating

3.41
Cooling
Conventional Conventional model
Conventional
Heating operation Stopped heating

Cooling Energy consumption

Real-time Smart Operation


Time
MULTI V lll Real-time

Heating

Therefore, higher COP and EER of a product makes its cooling and heating capability higher and energy consumption lower

power saving operation

Real-time power saving operation control Real-time Temperaturepower saving operation control
Temperature Room temperature Room temperature

COP Comparison(based 0n 8Hp)

MULTI V lll

The real-time power saving operation enables the product to automatically to adjust the indoor units to maintain optimal operation level and reduce power consumption.

Heating supply

ON
ON OFF

18(%) 100 18 Set temperature Set temperature 14 50 14 8 0

Peak P Pea k

Adequate discharge air temperature Adequate discharge air temperature

8
47 44

Discharge air temperature Discharge air temperature


(dBA) A

Energy saving Energy saving


41dBA

Time Time

ON

OFF

ON

OFF

ON

Conventional model

Heating supply

OFF

OFF

Heating operation rate

ON

Accumulated heating supply COP improvement


41 Capability

OFF

Capability compensation operation


During heating or cooling, MULTI V automatically checks the operation status and performs the capability compensation operation on indoor units if required.

compensation operation Capability compensation operation Temperature


4:00 8:00 12:00

MULTI V lll supply

Heating

OFF

OFF

Time

16%MULTI V lll

ON

OFF

ON

17%

OFF

ON

5%

8:00 12:00 Temperature

4:00

8:00

ON OFF

MULTI V III
MULTI V lll

Heating supply

Time

MULTI V lll

ON

MULTI V lll

ON

18 18 Set temperature Set temperature 14 14 Discharge air temperature

Room temperature Room temperature

Conventional
Heating supply
Heating operation rate Accumulated heating supply COP improvement
Time

OFF

MULTI V lll
ON

Time

Conventional heating

Continuous heating

Conventional Continuous heating heating

Heating operation

Continuous heating

16%

17%

5%

Conventional
Heating operation rate Accumulated heating supply COP improvement * Continuous heating operation can be switched to existing defrost mode depending on environmental conditions. Heating operation
Stopped heating
Conventional

Note : ON 1. Capacities are based on the following conditions OFF temp. 2C[35.6F]DB / 1C[33.8F]WB Indoor temp. 20C[68F]DB / 15C[59F]WB / Outdoor Interconnecting piping length 7.5m, Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification

Discharge air temperature

12 12

Adequate discharge air temperature Adequate discharge air temperature

Capability compensation Capability compensation


Time Time

16%

MULTI V lll

Conventional heating

17%

Continuous heating

Conventional Continuous heating heating

5%

Conventional

MULTI V lll

Conventional heating

Continuous heating

Conventional Continuous heating heating

18

19

Heat pump
Outdoor Unit_MULTI V

Extended Piping Length and Elevation


Through the use of inverter technology and sub-cooling control circuit technology, MULTI V III can be installed with longer piping lengths and greater elevation differences. This provides a more flexible design options for high rise buildings.

Space Utilization by Smaller Size


MULTI V III offers up to 20 HP for single unit and can be combined up to 80HP, which reduces installation costs and saves space for large areas.
Conventional \ 20HP MULTI V III \ 20HP

Longest piping length Max 225m**

Total piping length Max 1000m


20HP 20HP 38% 38% reduction reduction

12HP
25%
Conventional

20HP
38%

Reduction
MULTI V IIl

Reduction

Level difference between ODU*~IDU* Max 110m ODU* : Outdoor unit IDU* : Indoor unit ** : Equivalent

Level different between IDU*~IDU* Max 15m

Total piping length Longest piping length after 1st branch (Conditional application) Level difference between ODU~IDU Level difference between IDU~IDU Level difference between ODU~ODU

1000m

Actual longest pipe length (Equlvalent) 200m (225m*)


Longest piping length after 1st branch Max 90m

Maximum Combination Capacity of 80HP with a Single Pipe


A combination of up to 80 HP can be made using 20 HP units. This makes it possible to design a HVAC system that fits into an extensive space. The usual major problems in design, such as installation space for outdoor units, pipe shaft space and piping line, are no longer an issue.

40m (90m*) 110m 15m


5m

Outdoor unit combination of up to 80 HP


Installation space saving - Optimal space utilization Single pipe - Easy to design - Cooling and heating for an extensive space - Installation cost savings

Maximum Single Unit Capacity of 20HP


MULTI V III offers up to 20 HP for a single unit and up to 80HP can be combined which reduces installation costs and saves space for large areas. When designing a HVAC system with a total capacity of 400 HP, our 80 HP MULTI V lll combination give you the following 50% benefits, compared with conventional 40 HP combination models reduction
- Reduces the installation space and piping numbers by 29% - Reduces the pipe shaft space by 30% - A large capacity design reduces the time spent on designing the HVAC system, and also reduces the construction costs
30% reduction

Single Unit!!
50% reduction 29% reduction
30% reduction

20HP

Comparison of outdoor unit installation space


Conventional MULTI V III

One Fan 8~12HP

Two Fan 14~20HP


30% reduction

20

21

Heat pump
Outdoor Unit_MULTI V

New Designs for Low Noise Operation


To provide high cooling and heating performance in a small space with minimal noise, MULTI V III uses various low noise technologies. It has reduced noise by using a compressor that has BLDC motors, low noise fan motors, new soundproof technology, outdoor fans, and a newly developed shroud shape.

High Static Pressure Fan


MULTI V III uses a powerful high static pressure fan, which allows users to install not only on the roof, but also inside the building by using air ducts. (Maximum external static pressure : 8mmaq) Various design and installation methods can be used, that are tailored to the building structure.

50 40
Octangular grill air ow resistance reduction

43

30

Robust structure design

Robust structure design

Low torque motor with ripple design Resonance frequency shift with optimal current angle control

Expanded bellmouth shaped shroud

S-shaped blade increases pitch angle

Octangular grill air flow reduces resistance

20 10

Expanded bellmouth shaped shroud

-5

Eco-friendly Design
MULTI V III has been developed to be more eco-friendly, so that it has a reduced impact on the environment.
Low torque motor with ripple design Resonance frequency shift with optimal current angle control Robust & S-shaped blade Increased pitch angle

Wide Operation Range


ODP
1

-10

R410A Refrigerant
MULTI V III uses brazing in pipes to prevent refrigerant leakages. In case of any leakages, the automatic leak detection function notifies users and operates with the requisite amount of refrigerant

The product has an extended continuous cooling and heating operation range compared to conventional products. This extended operation range has been achieved by using an enhanced inverter compressor and control technology.

DBT
50 40 30

WBT
30 43 20 10 0 -10 -20 -30 -20

43C (DBT) 16

0.5

Zero
0 R12 R22 R134A R407C R410A

20 10 0

-5

No refrigerant leakage design and production


As the product has brazing to prevent refrigerant from leaking, no leakage will occur unless an external factor, such as an impact occurs, even when the product has been in use for a long time.
(ODP)
1

R410A
10000 8000

-10

Cooling

Heating

Brazing
0.5

Flexible Indoor Unit Combination


6000 4000

30 20

Zero

16 to 64 indoor units can be 2000 There are 13 types of unit that can be combined with a choice of 71 different 10 indoor units. Up connected to the MULTI 0V IIIR12system. R22 R134A R407C R410A 0
(GWP)
R410A

-20C (WBT)

Auto leakage detection

0
R12 R22 R134A R407C

-10 -20 -20

The product monitors the operation status data in real time and decides the appropriate amount of refrigerant and displays it. It also automatically notifies the user of any small refrigerant leakage.

Connectable Indoor -30 unit Capacity


Up to Max 200%

Number of Connectable Indoor Units


Up to

64

Variety of Indoor units

13 types, 71 models

Refrigerant recovery and reuse


MULTI V III collects refrigerant from pipes or indoor units which are not used and reuses them to reduce maintenance costs.

A combination with maximum 200% capcity can be achieved only if the changes of the heating and cooling load and the product operation rate by time are considered

Refrigerant recovery

Combination ratio(50~200%)
No.of outdoor unit Connection Capacity
200% 160% 130% 130%

Single unit Double unit Triple unit Over triple unit

22

23

Heat pump
Outdoor Unit_MULTI V

Easy and Safe Transportation


Being compact and lightweight the product is designed to be easily transported in a lift when the installation is in a building where it is difficult to use a crane. The product is designed for installers to be able to move it safely and easily. In addition, the larger capacity 20 HP unit makes installation work easier by reducing transportation and installation time. Lifting points are on the product, which can be used when transporting crane, this ensures safer transportation. The product design reduces installation time, enables safer transportation and all of these factors improve the MULTI V lll product reliability.

Automatic Detection for Incorrect Connections


In conventional products, if an installation engineer has connected a liquid line to a gas line by mistake, you have to check all of the piping line connections for the indoor units installed in the ceiling. However, MULTI V lll automatically checks the connections of piping and communication with its FDD (Fault Detection and Diagnosis) function and notifies the user if there is a problem. Usually, installation becomes more and more complex as the number of connected indoor units increases. But, with the automatic detection function, installation is made easier because when an indoor unit has a connection problem, you can take action quickly because the automatic detection function will inform the user of it.

Fast and safe transportation by a forklift


Forklift transportation holes at the bottom of the product, are designed to make it easy to load, transport and unload the product. There are also scratch prevention guides that prevent a forklift from damaging the product during transportation.

Forklift transportation hole Scratch prevention guide

Transportation by a forklift

Incorrect piping line connection (Liquid line + gas line)

Incorrect communication line connection

Safer design for crane use


Enhanced safety during transportation by a crane due to lifting holes that reduce the risk of the product falling and protect it from external impacts.

Crane rope hole

Transportation by crane

Communication lines

Communication lines

Compact dimensions allow transportation by lift


Since the product size is reduced, the product can be easily transported by lift.
Out

Transportation by lift

Real-time Fault Prediction Function


With conventional products, performance and reliability could be degraded due to a fault with a sensor or the EEV. However, Multi V allows you to check the current status of the sensors and the EEV, which are the major components for system control, through a auto test run. Since the auto test run can inspect the current status of the sensors and the EEV, you can be alerted to which one of them has a problem, so that action can be taken quickly even if a problem occurs within the normal operation range.

In

4-way Piping Connection


There are 4 ways to connect the outdoor unit piping (front/left/right/bottom) for customised installation depending on the site.

Sensor EEV

Error

Normal operation range

Right Left Front Bottom

4-way piping design

When installing piping lines on the floor (bottom piping)

24

25

Heat pump
Outdoor Unit_MULTI V

New Virtual Sensor Back-up Function


If an indoor unit sensor malfunctions with an abnormal value although it is detected as a faulty part, the outdoor unit can estimate what should be the normal sensor value and control the unit. This can improve system performance and reliability.

Automatic Refrigerant Recovery

Transfers refrigerant

In case of an indoor or outdoor unit replacement for SVC, refrigerant from the malfunctioning unit is transferred to the outdoor unit by pumping down or to an indoor unit by pumping out for easy SVC. PUMP DOWN PUMP OUT
Malfunction

Transfers refrigerant

Transfers refrigerant

Malfunction

Malfunctioning sensor

Virtual sensor value control Real-time sensor value check

Automatic Refrigerant Charging Function


refrigerant The FDD algorithm automatically supplies the correct amount of refrigerant using an electronic scale to increase installation reliability and product performance. Transfers

Intelligent Simple Test Run


The new test run mode provides an automatic test run report, which helps installation engineers to save time and effort. It also notifies the users of any operation errors, such as piping line/communication problem, refrigerant shortage, and secure product stability and reliability. Automatic test run mode saves more than 60% time compared to the manual mode.
Embedded with the FDD algorithm Indicated by the LED indicator when fully charged

Conventional Automatic test run results


st testtest test test te run run run run run

Automatic Emergency Back-up Function


If a compressor malfunctions, another compressor automatically operates as an back up to minimise any problems.

R R e ert pg R po o ep R Rep rt e in rt pin gin o in o rt rt in g go 3hr /gUnit


Reporting

Data back up

Setting

Connecting LGMV

Connecting PC

Test run

Use of a laptop or PDA

MULTI V III

Automatic reporting

Save 60% test run time


Setting

test run

test run

Reporting Reporting 1hr / Unit


Reporting
Submitted to the customer
Malfunction

Back-up operation

The automatic test run reduces test run time by more than 60% compared to the test run in an conventional product. It provides a safe, reliable and convenient test run with various data backup functions. Almost any installation worker, not just a highly trained engineer, can perform a test run. This can increase the competitiveness.

Even if an indoor unit malfunctions, the other indoor units operate normally because each indoor unit is operated individually by the Micom embedded in it.

Malfunction

26

27

Heat Recovery
Outdoor Unit_MULTI V

Synchronised Heating and Cooling


Possible to reach COP up to 7.1
(Under condition to 40% of cooling and 60% of heating)
Cooling
IT Room

Long Piping Length


As Multi V uses inverter control technology and sub-cooling control circuit technology, it is possible to design a system with longer piping lengths and world-class elevation difference.
Cooling

Energy consumption can be decreased by 30%


Cooling based operation

8 7 6 5 4 0

Max.COP(7.1)

Heating based operation


Heating
Gym

Total piping length Actual longest pipe length


Level difference between ODU and IDU Max 110m Level difference between HR unit 15m
Room

1000m 200m(225m*) 40m[90m*] 110m 15m


5m 15m 15m

Longest piping length after 1st branch Level difference between ODU~IDU Level difference between IDU~IDU Level difference between ODU~ODU Level difference between IDU~HR Unit Level difference between HR unit

Office

Heating
Level difference between IDU~IDU 15m

20

40

60

80

100

* Outdoor temperature : 7C DB / 6C WB * Indoor temperature : 20C DB / 15C WB

Longest piping length Max 200m(225m*)

* Equivalent ** Conditional application

Simultaneous Operations of Outdoor Units


The outdoor units heat exchanger can be operated for cooling and heating simultaneously. - Linear loading response - Increased efficiency with simultaneous operation - Minimised switch mode(continuous cooling and heating)
Conventional
ODU: Eva. Only or Cond. only HR Unit ODU: Eva. Only or Cond. only
Cool Heat

Total piping length 1000m

IDU

Convenient Free Zoning


MULTI V III Heat recovery provides flexible control over individual zones for the users convenience Individual Control - Individual control over the spaces where ventilation is needed Zone Control - Max. of 8 indoor units can be connected on one branch - Max. of 32 indoor units can be connected to one HR unit -Same opeational model can be operated by indoor units with zone control function installed Combination of Individual and Zoning Installations - Flexible piping design - Saves on product and installation Costs
IT Room Ofce Kitchen

MULTI V III

Cool

Heat

ODU: Cond. + Eva. Synchronously

Cool

Heat

IDU

IDU

Room

HR Unit

HR Unit

ODU: Cond. + Eva. Synchronously

AMC (Advanced Mode Change)


High Pressure

Cool

Heat

AMC control provides an optimal cycle operationIDU under any conditions. Through this mode, System Cycles can be more stable and maintain comfort for the user. - Real time pressure control - Optimal cycle in optimum area - Minimise settling time after switching mode : MAX 5 min.
HR Unit

COMP (Hz )

[Zoning control]
Mode Change ( Cond)

Mode Change (Eva )

Optimum Area
COMP (Hz )

HR unit

Zoning control (Max indoor unit 8EA)

Low Pressure

28

29

Heat Recovery
Outdoor Unit_MULTI V

High Efficiency Heat Recovery Unit


High efficient double spiral tube type SCI circuit Maximum 8 indoor units connectable per a branch Easy installation with auto piping detect function Access allowed to internal parts for SVC
Double spiral tube heat exchanger From outdoor Linear expansion valve

Auto Changeover
Auto Changeover function operates cooling and heating to maintain optimal room temperature.
Temp

Change point (Heat Cool)

+T -T

Change point (Heat Cool)

To indoor
PRHR021 PRHR031 PRHR041

2 phase fluid
Heat Cool Heat

Time

Flexible Connection of HR Unit


LGs heat recovery unit allows flexible connection both in series and in a row.
Conventional MULTI V III Heat Recovery

defrost Oil return Improved continuous heating operation (In case of series Unit, alternative defrost OFF per unit) OFF Heating - Integrated heating capacity : 17% up supply Heating mode oil return - Continuous heating and oil return during heating mode
Conventional
Conventional model Multi V III heat recovery

Non-stop Heating Operation

Conventional model

defrost

OFF

MULTI V III Heat Recovery

Time

defrost
Heating supply

Oil return

defrost

OFF

OFF

OFF

Partial defrost
Heating supply

Oil return (Heating mode)

Partial defrost

Y branch only

Impossible
In series
Multi V III heat recovery
Time Time

*Existing mode can be operated automatically, Oil returndepending on the condition of application.

Partial defrost

(Heating mode)

Partial defrost

Heating supply

Providing Various Applications

Impossible

In series only

Experience different operations simultaneously to provide optimal comfort with LG Air Conditioning system - Cooling/Heating Time - Fast Water Heating/Floor Heating - Ventilation/Humidification

Wide Operation Range


Heating(C DB), Cooling(C WB), Synchronous(C DB)

Colling & Heating


Indoor Temp.(C)

 xpanded Low Temperature Operation area through E Condenser with Various Control - Heating mode : - 20C WB ~ 16C WB - Cooling mode : - 10C DB ~ 43C DB - Synchronous mode : -10C WB ~ 16C WB NB : Where the hydrokit is used, maximum outdoor temperature for heating operation is 43C DB (instead of 16C WB).

Stantard Indoor Unit


27

Cooling
21

Operation area
15 14 10 -20

Synchronous

Hot water
Heat exchange DX Coil

Floor / Space heating


Humidification Supply Air Return Air

Cooling(Fan coil)

Heating
-10 -5 16 27 35 43 Outdoor Temp.(C)

Exhaust Air

Ventilation & Humidification

ECO V DX

Heating(C WB), Cooling(C DB), Synchronous(C WB)

Outdoor Air

30

31

Outdoor Unit_MULTI V

High Cooling and Heating Efficiency


High BLDC inverter compressor is used for optimal load and operation.

Easy Service
COP 1, 220V HP 4 5 6 Cooling 3.7 4.0 3.7 Heating 3.9 4.1 3.9 3, 380V Cooling 4.3 4.0 3.7 Heating 4.3 4.1 3.9
Quick and efficient installation of MULTI V MINI can provide the best solution for small offices and shops.

Convenient handles

Long Piping Length


Inverter control technology provides various types of system.
Longest piping length 150m(175m**)

Compact design and easy to service - Remove 3 screws for SVC - Front panel removal system

3 pieces of screw Easy service

1 2

Total piping length 300m

Total piping length Longest piping length (Equivalent)


Level difference between ODU and IDU Max 50m(40m*) Longest piping length after 1st branch 40m Level difference between IDU~IDU 15m

300m 150m(175m) 40m 50m(40m*) 15m


3

Inner SVC valve -  4 Way piping is possible


(Front, Rear, Right, Down)

Longest piping length after 1st branch Level difference between ODU~IDU Level difference between IDU~IDU
* When outdoor unit is lower than indoor unit.

- Excellent exterior
1 Way 4 Way

Max. 9 Indoor Units Connectable


Maximum of 9 units can be connected to a single outdoor unit with 130% indoor unit combination.
*Based on 6 HP model

2 2

3 3

4 4

5 5

Compact Dimensions
Longest piping length 150m(175m**)

Total piping length 300m

MULTI V Mini provides the optimal solution for small offices and shops.
Foot print area
Level difference between ODU and IDU Max 50m(40m*) Longest piping length after 1st branch 40m Level difference between IDU~IDU 15m

- 9 indoor units for 6HP - 8 indoor units for 5HP - 6 indoor units for 4HP

Units

32

730mm

Conventional 5, 6 HP

Reduction
806mm

46%

High Efficiency Outdoor Axial Fan


4, 5, 6 HP
950mm 330 mm

Axial fan provides high efficiency for heat exchange through a high air flow.
Applying High efficiency Axial Fan More powerful Heat exchange efficiency
28.0 26.6 25.2 23.8 22.4 21.0 19.6 18.2 16.8 15.4 14.0 12.6 11.2 9.8 8.4 7.0 5.6 4.2 2.8 1.4 0.0

Volume

52%
Reduction
Conventional 5, 6 HP Conventional 5, 6 HP

60%
Reduction
1 5HP,6HP 3 4HP,5HP,6HP 1 4 HP

460

520

8061607730

950x1380x330

8061607730

950x834x330

33

Outdoor Unit_MULTI V

Front Suction and Discharge


Right or left side air flow system High speed air discharging (7~8m/sec) No interference between floors (Efficiency reduction due to hot air back flow)
Conventional MULTI V SPACE II

Fan RPM Control (E.S.P & Noise Control)


MULTI V Space II technologies are covered by LGs domestic and international patents, some of them have been already registered.
How to set up

- E.S.P control
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Outdoor Duct Application


Step 1 : 4mmAq < ESP < 6mmAq Step 2 : 6mmAq < ESP < 8mmAq

No efficiency reduction! Interference between floors!


Hot air Building wind

1 2 3 4 5 6 7

8 9 10 11 12 13 14

1 2 3 4 5 6 7

8 9 10 11 12 13 14

Duct

Step 3 : 8mmAq < ESP < 10mmAq

7m/s

7m/s z zz zzz

1 2 3 4 5 6 7

8 9 10 11 12 13 14

Step 4 : 10mmAq < ESP < 12mmAq

- Noise control
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Low blowing noise : Max - 100 rpm

Discharging

Left Outoor unit

Right Outoor unit

Quiet Operation
Noise and vibration are reduced by - Front discharge - Sealed structure of outdoor unit The indoor noise level is maintained at 30~40dBA
Conventional MULTI V SPACE II

4-Step Modular Design

z z z
z

 The modular design of the outdoor unit provides simpler installation and maintenance.  Outdoor unit can be installed according to the building construction schedule. Louver is provided locally

LG Patent for MULTI V SPACE II


MULTI V Space II technologies have LGs domestic and international patents, which some of them have been already registered.
1
1 Whole structure (8 items) 2 Air handler structrue (18 items) 3 Separation of suction and discharge (6 items) 4 Louver structure /control (20 items) 5 3-side heat exchange structure (3 items) 6 Electrical part(2 items)

1steps Louver frame

2steps System louver

3steps Mechanical parts

4steps Fan parts


*6HP (ARUN60LR2, ARUN60LL2) *8HP (ARUN80LR2, ARUN80LL2)

2 4 5

LG patents : 57items

34

35

Outdoor Unit_MULTI V

Economic Water System


Regardless of outdoor temperature and other environmental conditions, MULTI V Water II is the optimal solution for high-rise buildings.
High efficiency system regardless of external conditions Optimised control by variable load High COP

Easy Installation and Compact Dimensions


Easy pipe work - Refrigerant and water pipe connection at the front
A company
Water piping Refrigerant piping

Lightweight and compact dimensions - Installation space is reduced up to 60% - Foot print is smaller than some other products on the market.
20HP

MULTI V Water II

100

28%

COP

60

Water piping
-14.7 -10.5 -8.5 -5.0 0.0 5.0

20HP 45% reduction


A company

45%Reduction
MULTI V Water II

20HP 45% reduction

Outside temp

Wind

Aircooled

MULTI V WATER II
Outdoor Units
Refrigerant piping

Capa. 20HP

A company

LG

Dimesion(WxDxH) m3 Dimesion(WxDxH) m3 1560x550x1000 0.86 772x547x1120 0.47

Compressor Back Up Operation


Auto back up operation (Applied to outdoor units with two compressors) If one of the two compressors malfunctions, the other compressor operates automatically to provide at least 50% of cooling and heating, and informs the status every 6 hours until the service is completed. Manual back up operation (Applied to one or two compressors) When two or more outdoor units are connected, the whole system stops if one of the outdoor units compressor malfunctions. In such cases, users can set up emergency mode to operate the other outdoor unit and maintain cooling and operation. Manual Back up setting with dip switch - Dip switch 3 on : Inverter Back up - Dip switch 4 on : Unit Back up (to operate total back up for one unit, when connected with two or more outdoor units)

MULTI V Water II System for Geothermal Applications


Uses underground heat sources such as soil, ground water, lake, river, etc. as renewable energy for the cooling and heating of a building. Water or antifreeze solution is circulated through the closed loop HDPE (High Density Poly-Ethylene) pipes buried beneath the earths surface. It is a highly efficient and eco-friendly MULTI V system. -The working water temperature range is between -5C~45C - Antifreeze should be applied depending on the application.
** This application should be consulted with local LG office

Variable Water Flow Control Kit (Optional)


Reduce water consumption by using the variable water flow control solution.  Adjusts water flow by pressure control after connecting PCB in the existing MULIT V Water Outdoor unit.
15,456

Longest Piping Length


Provides flexible installation with up to 300m of total piping length. The water pipes are not connected to the indoor units, so the users do not need to worry about any leakage. Total piping length Longest piping length (Equivalent) Longest piping length after 1st branch Level difference between ODU~IDU Level difference between IDU~IDU
*Outdoor unit is lower than indoor unit.

Total water flow(m3)

300m 150m(175m) 40m 50m(40m*) 15m

Level difference 50m Longest piping length 40m (after 1st branch)

Cooling Tower

Variable Water Flow Control Valve DC 0~10V

71%

Constant water flow

Variable water flow

Geothermal

Between Indoor units 15m


River / Sea

Inverter Pump

Note : 1. Location : France 2. Total operation time : 1,344 hr 3. Indoor temperature : normal office environment 4. Outdoor temperature : average summer temperature 5. Inlet flow temperature : approximately 30C

4,439

36

37

Heat pump
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

8
ARUN80LT3 ARUN80LT3

10
ARUN100LT3 ARUN100LT3

12
ARUN120LT3 ARUN120LT3

HP
Model Combination unit Independent unit

14
ARUN140LT3 ARUN140LT3

16
ARUN160LT3 ARUN160LT3

18
ARUN180LT3 ARUN180LT3

20
ARUN200LT3 ARUN200LT3

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

22.4 25.2 24.3 5.3 5.5 6.4 4.27 4.58

28.0 31.5 30.3 7.0 7.3 8.4 4.00 4.34 -5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 2 Propeller fan BLDC motor 190 58 (920x1,680x760)x1 240x1 R410A 6.4 EEV FVC68D(PVE) 5,200 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 9.52(3/8) 22.2(7/8) 1 16(25) 50 ~ 200% Wide Louver plus fin

33.6 37.8 36.4 8.9 9.0 10.4 3.78 4.20 -5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 2 Propeller fan BLDC motor 190 58 (920x1,680x760)x1 240x1 R410A 6.4 EEV FVC68D(PVE) 5,200 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 12.7(1/2) 28.58(1 1/8) 1 20(30) 50 ~ 200% Wide Louver plus fin

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 1 Propeller fan BLDC motor

Max Max WxHxD

m3/min dBA mm kg

180 57 (920x1,680x760)x1 190x1 R410A 5.0 EEV FVC68D(PVE)

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

39.2 44.1 42.5 9.5 9.7 11.2 4.13 4.55

44.8 50.4 44.1 11.0 11.5 13.3 4.07 4.38 -5C ~ 43C -20C ~ 16C 2 Propeller fan BLDC motor 210 61 (1,240x1,680x760)x1 260x1 R410A 7.0 EEV FVC68D(PVE) 5,500 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 12.7(1/2) 28.58(1 1/8) 1 26(40) 50 ~ 200% Wide Louver plus fin

50.4 56.7 54.6 12.8 13.5 15.6 3.94 4.20 -5C ~ 43C -20C ~ 16C 3 Propeller fan BLDC motor 240 62 (1,240x1,680x760)x1 315x1 R410A 7.5 EEV FVC68D(PVE) 7,200 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 15.88(5/8) 28.58(1 1/8) 1 29(45) 50 ~ 200% Wide Louver plus fin

56.0 63.0 60.7 15.0 15.5 17.9 3.73 4.06 -5C ~ 43C -20C ~ 16C 3 Propeller fan BLDC motor 250 62 (1,240x1,680x760)x1 325x1 R410A 9.0 EEV FVC68D(PVE) 7,200 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 15.88(5/8) 28.58(1 1/8) 1 32(50) 50 ~ 200% Wide Louver plus fin

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C 2 Propeller fan BLDC motor

Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll

Max Max WxHxD

m3/min dBA mm kg

210 58 (1,240x1,680x760)x1 260x1 R410A 7.0 EEV FVC68D(PVE)

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

3,500 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1,000 200(225) 40(90) 110 15 9.52(3/8) 19.05(3/4) 1 13(20) 50 ~ 200% Wide Louver plus fin

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

5,500 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 12.7(1/2) 28.58(1 1/8) 1 23(35) 50 ~ 200% Wide Louver plus fin

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

38

39

Heat pump
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

22
ARUN220LT3 ARUN120LT3 ARUN100LT3

24
ARUN240LT3 ARUN120LT3 ARUN120LT3

HP
Model Combination unit Independent unit

26
ARUN260LT3 ARUN140LT3 ARUN120LT3

28
ARUN280LT3 ARUN160LT3 ARUN120LT3

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

61.6 69.3 66.7 15.9 16.3 18.8 3.87 4.26

67.2 75.6 72.8 17.8 18.0 20.8 3.78 4.20 -5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor 400 61 (920x1,680x760)x2 240x2 R410A 12.8 EEV FVC68D(PVE) 10,700 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 15.88(5/8) 34.9(1 3/8) 2 39(48) 50 ~ 160% Wide Louver plus fin

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor

Max Max WxHxD

m3/min dBA mm kg

380 61 (920x1,680x760)x2 240x2 R410A 12.8 EEV FVC68D(PVE)

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

72.8 81.9 78.9 18.4 18.7 21.6 3.96 4.38

78.4 88.2 80.5 19.9 20.5 23.7 3.94 4.30 -5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor 400 61 (920x1,680x760)x1+ (1,240x1,680x760)x1 240x1+260x1 R410A 13.4 EEV FVC68D(PVE) 10,700 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 34.9(1 3/8) 2 45(56) 50 ~ 160% Wide Louver plus fin

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor

Max Max WxHxD

m3/min dBA mm kg

400 61 (920x1,680x760)x1+ (1,240x1,680x760)x1 240x1+260x1 R410A 13.4 EEV FVC68D(PVE)

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

10,400 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 15.88(5/8) 28.58(1 1/8) 2 35(44) 50 ~ 160% Wide Louver plus fin

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

10,700 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 34.9(1 3/8) 2 42(52) 50 ~ 160% Wide Louver plus fin

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

40

41

Heat pump
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

30
ARUN300LT3 ARUN160LT3 ARUN140LT3

32
ARUN320LT3 ARUN160LT3 ARUN160LT3

34
ARUN340LT3 ARUN180LT3 ARUN160LT3

HP
Model Combination unit Independent unit

36
ARUN360LT3 ARUN200LT3 ARUN160LT3

38
ARUN380LT3 ARUN200LT3 ARUN180LT3

40
ARUN400LT3 ARUN200LT3 ARUN200LT3

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

84.0 94.5 86.6 20.5 21.2 24.5 4.10 4.46

89.6 100.8 88.3 22.0 23.0 26.6 4.07 4.38 -5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor 420 63.5 (1,240x1,680x760)x2 2602 R410A 14.0 EEV FVC68D(PVE) 11,000 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 34.9(1 3/8) 2 52(64) 50 ~ 160% Wide Louver plus fin

95.2 107.1 98.7 23.8 25.0 28.9 4.00 4.28 -5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 5 Propeller fan BLDC motor 450 63.5 (1,240x1,680x760)x2 2601+3151 R410A 14.5 EEV FVC68D(PVE) 12,700 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 34.9(1 3/8) 2 55(64) 50 ~ 160% Wide Louver plus fin

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor

Max Max WxHxD

m3/min dBA mm kg

420 62.8 (1,240x1,680x760)x2 2602 R410A 14.0 EEV FVC68D(PVE)

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

100.8 113.4 104.8 26.0 27.0 31.2 3.88 4.20

106.4 119.7 115.2 27.8 29.0 33.5 3.83 4.13 -5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 6 Propeller fan BLDC motor 490 65 (1,240x1,680x760)x2 315 x 1 + 325 x 1 R410A 16.5 EEV FVC68D(PVE) 14,400 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 2 61(64) 50 ~ 160% Wide Louver plus fin

112.0 126.0 121.3 30.0 31.0 35.8 3.73 4.06 -5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 6 Propeller fan BLDC motor 500 65 (1,240x1,680x760)x2 325 x 2 R410A 18.0 EEV FVC68D(PVE) 14,400 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 2 64 50 ~ 160% Wide Louver plus fin

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 5 Propeller fan BLDC motor

Max Max WxHxD

m3/min dBA mm kg

460 65 (1,240x1,680x760)x2 260 1 + 325 1 R410A 16.0 EEV FVC68D(PVE)

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

11,000 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 34.9(1 3/8) 2 49(60) 50 ~ 160% Wide Louver plus fin

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

12,700 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 2 58(64) 50 ~ 160% Wide Louver plus fin

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

42

43

Heat pump
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

42
ARUN420LT3 ARUN160LT3 ARUN140LT3 ARUN120LT3
Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling Nom Nom Max Nom Nom Max kW kW kW kW kW kW
117.6 132.3 123.0 29.4 30.2 34.9 4.00 4.38

44
ARUN440LT3 ARUN160LT3 ARUN160LT3 ARUN120LT3
123.2 138.6 124.7 30.9 32.0 37.0 3.99 4.33 -5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 6 Propeller fan BLDC motor 610 64 (9201,680760)1+ (1,2401,680760)2 2401+2602 R410A 20.4 EEV FVC68D(PVE) 16,200 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Wide Louver plus fin

HP
Model Combination unit Independent unit

46
ARUN460LT3 ARUN160LT3 ARUN160LT3 ARUN140LT3
Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling Nom Nom Max Nom Nom Max kW kW kW kW kW kW
128.8 144.9 130.7 31.5 32.7 37.8 4.09 4.43

48
ARUN480LT3 ARUN160LT3 ARUN160LT3 ARUN160LT3
134.4 151.2 132.4 33.0 34.5 39.9 4.07 4.38 -5C ~ 43C -20C ~ 16C 6 Propeller fan BLDC motor 630 64.5 (1,240x1,680x760)x3 2603 R410A 21.0 EEV FVC68D(PVE) 16,500 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Wide Louver plus fin

50
ARUN500LT3 ARUN180LT3 ARUN160LT3 ARUN160LT3
140.0 157.5 142.9 34.8 36.5 42.2 4.02 4.32 -5C ~ 43C -20C ~ 16C 7 Propeller fan BLDC motor 660 65.4 (1,240x1,680x760)x3 2602+3151 R410A 21.5 EEV FVC68D(PVE) 18,200 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Wide Louver plus fin

52
ARUN520LT3 ARUN200LT3 ARUN160LT3 ARUN160LT3
145.6 163.8 148.9 37.0 38.5 44.5 3.94 4.25 -5C ~ 43C -20C ~ 16C 7 Propeller fan BLDC motor 670 65.8 (1,240x1,680x760)x3 2602+3251 R410A 23.0 EEV FVC68D(PVE) 18,200 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Wide Louver plus fin

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 6 Propeller fan BLDC motor

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C 6 Propeller fan BLDC motor

Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll

Max Max WxHxD

m3/min dBA mm kg

610 62.8 (9201,680760)1+ (1,2401,680760)2 2401+2602 R410A 20.4 EEV FVC68D(PVE)

Max Max WxHxD

m3/min dBA mm kg

630 64.5 (1,240x1,680x760)x3 2603 R410A 21.0 EEV FVC68D(PVE)

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

16,200 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Wide Louver plus fin

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

16,500 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Wide Louver plus fin

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

44

45

Heat pump
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

54
ARUN540LT3 ARUN200LT3 ARUN200LT3 ARUN140LT3
Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling Nom Nom Max Nom Nom Max kW kW kW kW kW kW
151.2 170.1 163.8 39.5 40.7 47.1 3.83 4.18

56
ARUN560LT3 ARUN200LT3 ARUN200LT3 ARUN160LT3
156.8 176.4 165.5 41.0 42.5 49.1 3.82 4.15 -5C ~ 43C -20C ~ 16C 8 Propeller fan BLDC motor 710 66.5 (1,240x1,680x760)x3 260x1+325x2 R410A 25.0 EEV FVC68D(PVE) 19,900 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Wide Louver plus fin

58
ARUN580LT3 ARUN200LT3 ARUN200LT3 ARUN180LT3
162.4 182.7 175.9 42.8 44.5 51.4 3.79 4.11 -5C ~ 43C -20C ~ 16C 9 Propeller fan BLDC motor 740 66.8 (1,240x1,680x760)x3 315x1+325x2 R410A 25.5 EEV FVC68D(PVE) 21,600 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Wide Louver plus fin

60
ARUN600LT3 ARUN200LT3 ARUN200LT3 ARUN200LT3
168.0 189.0 182.0 45.0 46.5 53.8 3.73 4.06 -5C ~ 43C -20C ~ 16C 9 Propeller fan BLDC motor 750 66.8 (1,240x1,680x760)x3 325x3 R410A 27.0 EEV FVC68D(PVE) 21,600 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Wide Louver plus fin

HP
Model Combination unit Independent unit

62

64

66

68

70

ARUN620LT3 ARUN640LT3 ARUN660LT3 ARUN680LT3 ARUN700LT3 ARUN160LT3 ARUN160LT3 ARUN180LT3 ARUN180LT3 ARUN200LT3 ARUN160LT3 ARUN160LT3 ARUN160LT3 ARUN180LT3 ARUN180LT3 ARUN160LT3 ARUN160LT3 ARUN160LT3 ARUN160LT3 ARUN160LT3 ARUN140LT3 ARUN160LT3 ARUN160LT3 ARUN160LT3 ARUN160LT3

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C 8 Propeller fan BLDC motor

Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll

Max Max WxHxD

m3/min dBA mm kg

710 65.8 (1,240x1,680x760)x3 260x1+325x2 R410A 25.0 EEV FVC68D(PVE)

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

173.6 195.3 174.9 42.5 44.2 51.1 4.08 4.42

179.2 201.6 176.6 44.0 46.0 53.2 4.07 4.38 -5C ~ 43C -20C ~ 16C 8 Propeller fan BLDC motor 840 67

184.8 207.9 187.0 45.8 48.0 55.5 4.03 4.33 -5C ~ 43C -20C ~ 16C 9 Propeller fan BLDC motor 870 67.3

190.4 214.2 197.5 47.6 50.0 57.8 4.00 4.28 -5C ~ 43C -20C ~ 16C 10 Propeller fan BLDC motor 900 67.5

196.0 220.5 203.5 49.8 52.0 60.1 3.94 4.24 -5C ~ 43C -20C ~ 16C 10 Propeller fan BLDC motor 910 67.5

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C 8 Propeller fan BLDC motor

Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll

Max Max WxHxD

m3/min dBA mm kg

840 66.4

(1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) x4 x4 x4 x4 x4 260x4 R410A 28.0 EEV FVC68D(PVE) 260x4 R410A 28.0 EEV FVC68D(PVE) 22,000 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 22.2(7/8) 44.5(1 3/4) 4 64 50 ~ 130% 2603+3151 R410A 28.5 EEV FVC68D(PVE) 23,700 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2) 4 64 50 ~ 130% 2602+3152 R410A 29.0 EEV FVC68D(PVE) 25,400 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2) 4 64 50 ~ 130% 2602+3151+3251 R410A 30.5 EEV FVC68D(PVE) 25,400 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2) 4 64 50 ~ 130%

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

19,900 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Wide Louver plus fin

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

22,000 cc 3 / 380-415 / 50 /V/Hz No. x mm 2C x 1.0 ~ 1.5 1000 m 200(225) m 40(90) m 110 m 15 m 22.2(7/8) mm(inch) 44.5(1 3/4) mm(inch) 4 64 50 ~ 130%

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin

46

47

Heat pump
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

72

74

76

78

80

ARUN720LT3 ARUN740LT3 ARUN760LT3 ARUN780LT3 ARUN800LT3 ARUN200LT3 ARUN200LT3 ARUN200LT3 ARUN200LT3 ARUN200LT3 ARUN200LT3 ARUN200LT3 ARUN200LT3 ARUN200LT3 ARUN200LT3 ARUN160LT3 ARUN180LT3 ARUN200LT3 ARUN200LT3 ARUN200LT3 ARUN160LT3 ARUN160LT3 ARUN160LT3 ARUN180LT3 ARUN200LT3

* ( ) : equivalent length ** Conditional Application To make 40~90m of pipe length after first branch refer to the part of installation of outdoor units in PDB *** ( ) : the number of max. connectable indoor units, for max indoor unit combination ratio (refer to the table below) Note :
1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m Interconnecting piping length 7.5m Level difference of zero Level difference of zero 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

201.6 226.6 209.6 52.0 54.0 62.4 3.88 4.20

207.2 233.1 220.0 53.8 56.0 64.7 3.85 4.16 -5C ~ 43C -20C ~ 16C 11 Propeller fan BLDC motor 950 67.8

212.8 239.4 226.1 56.0 58.0 67.1 3.80 4.13 -5C ~ 43C -20C ~ 16C 11 Propeller fan BLDC motor 960 67.8

218.4 245.7 236.6 57.8 60.0 69.4 3.78 4.10 -5C ~ 43C -20C ~ 16C 12 Propeller fan BLDC motor 990 68

224.0 252.0 242.6 60.0 62.0 71.7 3.73 4.06 -5C ~ 43C -20C ~ 16C 12 Propeller fan BLDC motor 1,000 68

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C 10 Propeller fan BLDC motor

CAUTION
A combination operation over 100% cause to reduce each indoor unit capacity Combination ratio(50~200%)
No. of outdoor unit Single unit Double unit Triple unit Over triple unit Connection Capacity 200% 160% 130% 130%

Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll

Max Max WxHxD

m3/min dBA mm kg

920 67.5

(1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) x4 x4 x4 x4 x4 2602+3252 R410A 32.0 EEV FVC68D(PVE) 2601+3151+3252 R410A 32.5 EEV FVC68D(PVE) 27,100 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2) 4 64 50 ~ 130% 2601+3253 R410A 34.0 EEV FVC68D(PVE) 27,100 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2) 4 64 50 ~ 130% 3151+3253 R410A 34.5 EEV FVC68D(PVE) 28,800 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2) 4 64 50 ~ 130% 3254 R410A 36.0 EEV FVC68D(PVE) 28,800 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2) 4 64 50 ~ 130%

We can guarantee the operation only within 130% Combination. If you want to connect more than 130% combination, please contact us and discuss the requirement like below. 1) If the operational capacity of indoor units exceed 130%, then all the indoor units operate under low air flow step mode. 2) Over 130%, capacity is same as capacity of 130%, Same remark is valid for power input.

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

25,400 cc 3 / 380-415 / 50 /V/Hz No. x mm 2C x 1.0 ~ 1.5 1000 m 200(225) m 40(90) m 110 m 15 m 22.2(7/8) mm(inch) 53.98(2) mm(inch) 4 64 50 ~ 130%

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin

48

49

Heat Recovery
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

8
ARUB80LT3 ARUB80LT3

10
ARUB100LT3 ARUB100LT3

12
ARUB120LT3 ARUB120LT3

HP
Model Combination unit Independent unit

14
ARUB140LT3 ARUB140LT3

16
ARUB160LT3 ARUB160LT3

18
ARUB180LT3 ARUB180LT3

20
ARUB200LT3 ARUB200LT3

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

22.4 25.2 24.3 5.3 5.5 6.4 4.27 4.58

28.0 31.5 30.3 7.0 7.3 8.4 4.00 4.34 -10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 2 Propeller fan BLDC motor 190 58 (920x1,680x760)x1 2401 R410A 6.4 EEV FVC68D(PVE) 5,200 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 9.52(3/8) 22.2(7/8) 19.05(3/4) 1 16(25) 50 ~ 200% Wide Louver plus fin

33.6 37.8 36.4 8.9 9.0 10.4 3.78 4.20 -10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 2 Propeller fan BLDC motor 190 58 (920x1,680x760)x1 2401 R410A 6.4 EEV FVC68D(PVE) 5,200 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 12.7(1/2) 28.58(1 1/8) 19.05(3/4) 1 20(30) 50 ~ 200% Wide Louver plus fin

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Min~Max C DB Min~Max C WB

-10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 1 Propeller fan BLDC motor

Max Max WxHxD

m3/min dBA mm kg

180 57 (920x1,680x760)x1 1901 R410A 5.0 EEV FVC68D(PVE)

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

39.2 44.1 42.5 9.5 9.7 11.2 4.13 4.55

44.8 50.4 44.1 11.0 11.5 13.3 4.07 4.38 -10C ~ 43C -20C ~ 16C 2 Propeller fan BLDC motor 210 61 (1,240x1,680x760)x1 2701 R410A 7.0 EEV FVC68D(PVE) 5,500 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 12.7(1/2) 28.58(1 1/8) 22.2(7/8) 1 26(40) 50 ~ 200% Wide Louver plus fin

50.4 56.7 54.6 12.8 13.5 15.6 3.94 4.20 -10C ~ 43C -20C ~ 16C 3 Propeller fan BLDC motor 240 62 (1,240x1,680x760)x1 3151 R410A 7.5 EEV FVC68D(PVE) 7,200 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 15.88(5/8) 28.58(1 1/8) 22.2(7/8) 1 29(45) 50 ~ 200% Wide Louver plus fin

56.0 63.0 60.7 15.0 15.5 17.9 3.73 4.06 -10C ~ 43C -20C ~ 16C 3 Propeller fan BLDC motor 250 61 (1,240x1,680x760)x1 3251 R410A 9.0 EEV FVC68D(PVE) 7,200 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 15.88(5/8) 28.58(1 1/8) 22.2(7/8) 1 32(50) 50 ~ 200% Wide Louver plus fin

Min~Max C DB Min~Max C WB

-10C ~ 43C -20C ~ 16C 2 Propeller fan BLDC motor

Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll

Max Max WxHxD

m3/min dBA mm kg

210 58 (1,240x1,680x760)x1 2701 R410A 7.0 EEV FVC68D(PVE)

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas Max Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

3,500 3 / 380-415 / 50 2C x 1.0 ~ 1.5 1,000 200(225) 40(90) 110 15 9.52(3/8) 19.05(3/4) 15.88(5/8) 1 13(20) 50 ~ 200% Wide Louver plus fin

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas Max Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

5,500 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 12.7(1/2) 28.58(1 1/8) 22.2(7/8) 1 23(35) 50 ~ 200% Wide Louver plus fin

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

50

51

Heat Recovery
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

22
ARUB220LT3 ARUB120LT3 ARUB100LT3

24
ARUB240LT3 ARUB120LT3 ARUB120LT3

HP
Model Combination unit Independent unit

26
ARUB260LT3 ARUB140LT3 ARUB120LT3

28
ARUB280LT3 ARUB160LT3 ARUB120LT3

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

61.6 69.3 66.7 15.9 16.3 18.8 3.87 4.26

67.2 75.6 72.8 17.8 18.0 20.8 3.78 4.20 -10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor 400 61 (920x1,680x760)x2 2402 R410A 12.8 EEV FVC68D(PVE) 10,700 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 15.88(5/8) 34.9(1 3/8) 28.58(1 1/8) 2 39(48) 50 ~ 160% Wide Louver plus fin

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Min~Max C DB Min~Max C WB

-10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor

Max Max WxHxD

m3/min dBA mm kg

380 61 (920x1,680x760)x2 2402 R410A 12.8 EEV FVC68D(PVE)

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

72.8 81.9 78.9 18.4 18.7 21.6 3.96 4.38

78.4 88.2 80.5 19.9 20.5 23.7 3.94 4.30 -10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor 400 61 (920x1,680x760)x1+ (1,240x1,680x760)x1 2401+2701 R410A 13.4 EEV FVC68D(PVE) 10,700 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 34.9(1 3/8) 28.58(1 1/8) 2 45(56) 50 ~ 160% Wide Louver plus fin

Min~Max C DB Min~Max C WB

-10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor

Max Max WxHxD

m3/min dBA mm kg

400 61 (920x1,680x760)x1+ (1,240x1,680x760)x1 2401+2701 R410A 13.4 EEV FVC68D(PVE)

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas Max Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

10,400 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 15.88(5/8) 34.9(1 3/8) 28.58(1 1/8) 2 35(44) 50 ~ 160% Wide Louver plus fin

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas Max Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

10,700 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 34.9(1 3/8) 28.58(1 1/8) 2 42(52) 50 ~ 160% Wide Louver plus fin

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

52

53

Heat Recovery
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

30
ARUB300LT3 ARUB160LT3 ARUB140LT3

32
ARUB320LT3 ARUB160LT3 ARUB160LT3

34
ARUB340LT3 ARUB180LT3 ARUB160LT3

HP
Model Combination unit Independent unit

36
ARUB360LT3 ARUB200LT3 ARUB160LT3

38
ARUB380LT3 ARUB200LT3 ARUB180LT3

40
ARUB400LT3 ARUB200LT3 ARUB200LT3

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

84.0 94.5 86.6 20.5 21.2 24.5 4.10 4.46

89.6 100.8 88.3 22.0 23.0 26.6 4.07 4.38 -10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor 420 63.5 (1,240x1,680x760)x2 2702 R410A 14.0 EEV FVC68D(PVE) 11,000 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 34.9(1 3/8) 28.58(1 1/8) 2 52(64) 50 ~ 160% Wide Louver plus fin

95.2 107.1 98.7 23.8 25.0 28.9 4.00 4.28 -10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 5 Propeller fan BLDC motor 450 63.5 (1,240x1,680x760)x2 2701+3151 R410A 14.5 16 FVC68D(PVE) 12,700 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 34.9(1 3/8) 28.58(1 1/8) 2 55(64) 50 ~ 160% Wide Louver plus fin

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Min~Max C DB Min~Max C WB

-10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 4 Propeller fan BLDC motor

Max Max WxHxD

m3/min dBA mm kg

420 62.8 (1,240x1,680x760)x2 2702 R410A 14.0 EEV FVC68D(PVE)

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

100.8 113.4 104.8 26.0 27.0 31.2 3.88 4.20

106.4 119.7 115.2 27.8 29.0 33.5 3.83 4.13 -10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 6 Propeller fan BLDC motor 490 65 (1,240x1,680x760)x2 3151+3251 R410A 16.5 EEV FVC68D(PVE) 14,400 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 2 61(64) 50 ~ 160% Wide Louver plus fin

112.0 126.0 121.3 30.0 31.0 35.8 3.73 4.06 -10C ~ 43C -10C ~ 43C Hermetically Sealed Scroll 6 Propeller fan BLDC motor 500 65 (1,240x1,680x760)x2 3252 R410A 18.0 EEV FVC68D(PVE) 14,400 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 2 64 50 ~ 160% Wide Louver plus fin

Min~Max C DB Min~Max C WB

-10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 5 Propeller fan BLDC motor

Max Max WxHxD

m3/min dBA mm kg

460 65 (1,240x1,680x760)x2 2701+3251 R410A 16.0 EEV FVC68D(PVE)

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas Max Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

11,000 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 34.9(1 3/8) 28.58(1 1/8) 2 49(60) 50 ~ 160% Wide Louver plus fin

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas Max Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

12,700 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 28.58(1 1/8) 2 58(64) 50 ~ 160% Wide Louver plus fin

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

54

55

Heat Recovery
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

42
ARUB420LT3 ARUB160LT3 ARUB140LT3 ARUB120LT3
Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling Nom Nom Max Nom Nom Max kW kW kW kW kW kW
117.6 132.3 123.0 29.4 30.2 34.9 4.00 4.38

44
ARUB440LT3 ARUB160LT3 ARUB160LT3 ARUB120LT3
123.2 138.6 124.7 30.9 32.0 37.0 3.99 4.33 -10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 6 Propeller fan BLDC motor 610 64 (9201,680760)1+ (1,2401,680760)2 2401+2702 R410A 20.4 EEV FVC68D(PVE) 16,200 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Wide Louver plus fin

HP
Model Combination unit Independent unit

46
ARUB460LT3 ARUB160LT3 ARUB160LT3 ARUB140LT3
Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling Nom Nom Max Nom Nom Max kW kW kW kW kW kW
128.8 144.9 130.7 31.5 32.7 37.8 4.09 4.43

48
ARUB480LT3 ARUB160LT3 ARUB160LT3 ARUB160LT3
134.4 151.2 132.4 33.0 34.5 39.9 4.07 4.38 -10C ~ 43C -20C ~ 16C 6 Propeller fan BLDC motor 630 64.5 (1,240x1,68 x760)x3 2703 R410A 210.0 EEV FVC68D(PVE) 16,500 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Wide Louver plus fin

50
ARUB500LT3 ARUB180LT3 ARUB160LT3 ARUB160LT3
140.0 157.5 142.9 34.8 36.5 42.2 4.02 4.32 -10C ~ 43C -20C ~ 16C 7 Propeller fan BLDC motor 660 65.4 (1,240x1,68 x760)x3 2702+3151 R410A 21.5 EEV FVC68D(PVE) 18,200 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Wide Louver plus fin

52
ARUB520LT3 ARUB200LT3 ARUB160LT3 ARUB160LT3
145.6 163.8 148.9 37.0 38.5 44.5 3.94 4.25 -10C ~ 43C -20C ~ 16C 7 Propeller fan BLDC motor 670 65.8 (1,240x1,68 x760)x3 2702+3251 R410A 23.0 EEV FVC68D(PVE) 18,200 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Wide Louver plus fin

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Min~Max C DB Min~Max C WB

-10C ~ 43C -20C ~ 16C Hermetically Sealed Scroll 6 Propeller fan BLDC motor

Min~Max C DB Min~Max C WB

-10C ~ 43C -20C ~ 16C 6 Propeller fan BLDC motor

Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll

Max Max WxHxD

m3/min dBA mm kg

610 62.8 (9201,680760)1+ (1,2401,680760)2 2401+2702 R410A 20.4 EEV FVC68D(PVE)

Max Max WxHxD

m3/min dBA mm kg

630 64.5 (1,240x1,68 x760)x3 2703 R410A 210.0 EEV FVC68D(PVE)

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas Max Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

16,200 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Wide Louver plus fin

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas Max Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

16,500 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Wide Louver plus fin

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

56

57

Heat Recovery
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

54
ARUB540LT3 ARUB200LT3 ARUB200LT3 ARUB140LT3
Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling Nom Nom Max Nom Nom Max kW kW kW kW kW kW
151.2 170.1 163.8 39.5 40.7 47.1 3.83 4.18

56
ARUB560LT3 ARUB200LT3 ARUB200LT3 ARUB160LT3
156.8 176.4 165.5 41.0 42.5 49.1 3.82 4.15 -10C ~ 43C -20C ~ 16C 8 Propeller fan BLDC motor 710 66.5 (1,240x1,680x760)x3 2701+3252 R410A 25.0 EEV FVC68D(PVE) 19,900 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Wide Louver plus fin

58
ARUB580LT3 ARUB200LT3 ARUB200LT3 ARUB180LT3
162.4 182.7 175.9 42.8 44.5 51.4 3.79 4.11 -10C ~ 43C -20C ~ 16C 9 Propeller fan BLDC motor 740 66.8 (1,240x1,680x760)x3 3151+3252 R410A 25.5 EEV FVC68D(PVE) 21,600 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Wide Louver plus fin

60
ARUB600LT3 ARUB200LT3 ARUB200LT3 ARUB200LT3
168.0 189.0 182.0 45.0 46.5 53.8 3.73 4.06 -10C ~ 43C -10C ~ 43C 9 Propeller fan BLDC motor 750 66.8 (1,240x1,680x760)x3 3253 R410A 27.0 EEV FVC68D(PVE) 21,600 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Wide Louver plus fin

HP
Model Combination unit Independent unit

62

64

66

68

70

ARUB620LT3 ARUB640LT3 ARUB660LT3 ARUB680LT3 ARUB700LT3 ARUB160LT3 ARUB160LT3 ARUB180LT3 ARUB180LT3 ARUB200LT3 ARUB160LT3 ARUB160LT3 ARUB160LT3 ARUB180LT3 ARUB180LT3 ARUB160LT3 ARUB160LT3 ARUB160LT3 ARUB160LT3 ARUB160LT3 ARUB140LT3 ARUB160LT3 ARUB160LT3 ARUB160LT3 ARUB160LT3

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Min~Max C DB Min~Max C WB

-10C ~ 43C -20C ~ 16C 8 Propeller fan BLDC motor

Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll

Max Max WxHxD

m3/min dBA mm kg

710 65.8 (1,240x1,680x760)x3 2701+3252 R410A 25.0 EEV FVC68D(PVE)

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

173.6 195.3 174.9 42.5 44.2 51.1 4.08 4.42

179.2 201.6 176.6 44.0 46.0 53.2 4.07 4.38 -10C ~ 43C -20C ~ 16C 8 Propeller fan BLDC motor 840 67

184.8 207.9 187.0 45.8 48.0 55.5 4.03 4.33 -10C ~ 43C -10C ~ 43C 9 Propeller fan BLDC motor 870 67.3

190.4 214.2 197.5 47.6 50.0 57.8 4.00 4.28 -10C ~ 43C -20C ~ 16C 10 Propeller fan BLDC motor 900 67.5

196.0 220.5 203.5 49.8 52.0 60.1 3.94 4.24 -10C ~ 43C -20C ~ 16C 10 Propeller fan BLDC motor 910 67.5

Min~Max C DB Min~Max C WB

-10C ~ 43C -20C ~ 16C 8 Propeller fan BLDC motor

Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll

Max Max WxHxD

m3/min dBA mm kg

840 66.4

(1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) x4 x4 x4 x4 x4 2704 R410A 28.0 EEV FVC68D(PVE) 2704 R410A 28.0 EEV FVC68D(PVE) 22,000 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 22.2(7/8) 44.5(1 3/4) 41.3(1 5/8) 4 64 50 ~ 130% 2703+3151 R410A 28.5 EEV FVC68D(PVE) 23,700 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2 1/8) 44.5(1 3/4) 4 64 50 ~ 130% 2702+3152 R410A 29.0 EEV FVC68D(PVE) 25,400 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2 1/8) 44.5(1 3/4) 4 64 50 ~ 130% 2702+3151+3251 R410A 30.5 EEV FVC68D(PVE) 25,400 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2 1/8) 44.5(1 3/4) 4 64 50 ~ 130%

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas Max Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

19,900 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 19.05(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Wide Louver plus fin

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas Max Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

22,000 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 22.2(7/8) 44.5(1 3/4) 41.3(1 5/8) 4 64 50 ~ 130%

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin

58

59

Heat Recovery
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

72

74

76

78

80

ARUB720LT3 ARUB740LT3 ARUB760LT3 ARUB780LT3 ARUB800LT3 ARUB200LT3 ARUB200LT3 ARUB200LT3 ARUB200LT3 ARUB200LT3 ARUB200LT3 ARUB200LT3 ARUB200LT3 ARUB200LT3 ARUB200LT3 ARUB160LT3 ARUB180LT3 ARUB200LT3 ARUB200LT3 ARUB200LT3 ARUB160LT3 ARUB160LT3 ARUB160LT3 ARUB180LT3 ARUB200LT3

* ( ) : equivalent length ** Conditional Application To make 40~90m of pipe length after first branch refer to the part of installation of outdoor units in PDB *** ( ) : the number of max. connectable indoor units, for max indoor unit combination ratio (refer to the table below) Note :
1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m Interconnecting piping length 7.5m Level difference of zero Level difference of zero 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve

Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection

Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling

Nom Nom Max Nom Nom Max

kW kW kW kW kW kW

201.6 226.6 209.6 52.0 54.0 62.4 3.88 4.20

207.2 233.1 220.0 53.8 56.0 64.7 3.85 4.16 -10C ~ 43C -20C ~ 16C 11 Propeller fan BLDC motor 950 67.8

212.8 239.4 226.1 56.0 58.0 67.1 3.80 4.13 -10C ~ 43C -20C ~ 16C 11 Propeller fan BLDC motor 960 67.8

218.4 245.7 236.6 57.8 60.0 69.4 3.78 4.10 -10C ~ 43C -20C ~ 16C 12 Propeller fan BLDC motor 990 68

224.0 252.0 242.6 60.0 62.0 71.7 3.73 4.06 -10C ~ 43C -20C ~ 16C 12 Propeller fan BLDC motor 1000 68

Min~Max C DB Min~Max C WB

-10C ~ 43C -20C ~ 16C 10 Propeller fan BLDC motor

CAUTION
A combination operation over 100% cause to reduce each indoor unit capacity Combination ratio(50~200%)
No. of outdoor unit Single unit Double unit Triple unit Over triple unit Connection Capacity 200% 160% 130% 130%

Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll Hermetically Sealed Scroll

Max Max WxHxD

m3/min dBA mm kg

920 67.5

(1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) (1,240x1,680x760) x4 x4 x4 x4 x4 2702+3252 R410A 32.0 EEV FVC68D(PVE) 2701+3151+3252 R410A 32.5 EEV FVC68D(PVE) 27,100 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2 1/8) 44.5(1 3/4) 4 64 50 ~ 130% 2701+3253 R410A 34.0 EEV FVC68D(PVE) 27,100 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2 1/8) 44.5(1 3/4) 4 64 50 ~ 130% 3151+3253 R410A 34.5 EEV FVC68D(PVE) 28,800 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2 1/8) 44.5(1 3/4) 4 64 50 ~ 130% 3254 R410A 36.0 EEV FVC68D(PVE) 28,800 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2 1/8) 44.5(1 3/4) 4 64 50 ~ 130%

We can guarantee the operation only within 130% Combination. If you want to connect more than 130% combination, please contact us and discuss the requirement like below. 1) If the operational capacity of indoor units exceed 130%, then all the indoor units operate under low air flow step mode. 2) Over 130%, capacity is same as capacity of 130%, Same remark is valid for power input.

Type Charge Control Type Control

kg

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas Max Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

25,400 3, 380-415, 50 1.0 ~ 1.5 2C 1000 200(225) 40(90) 110 15 22.2(7/8) 53.98(2 1/8) 44.5(1 3/4) 4 64 50 ~ 130%

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type

Max Min-Max

Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin Wide Louver plus fin

60

61

Heat pump
Outdoor Unit_MULTI V

1 4HP

1 5HP,6HP

3 4HP,5HP,6HP

1 / 220V
HP
Model
Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas Max Max Max Max Max

3 / 380V
4
Combination unit
Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling Nom Nom Max Nom Nom Max kW kW kW kW kW kW

5
ARUN50GS2A
14.0 16.0 14.6 3.5 3.9 4.76 4.00 4.10 -5C ~ 48C -20C ~ 16C DC INV Rotary 1 BLDC BLDC motor 110 53 950x1,380x330 106 R410A 3.0 EEV FVC68D 1,300 1 / 220-240 / 50 2C x 1.0 ~ 1.5 300 150(175) 40 50(40) 15 9.52(3/8) 15.88(5/8) 1 8 50 ~ 130% Wide Louver plus fin

6
ARUN60GS2A
15.5 18.0 16.4 4.2 4.6 5.61 3.69 3.91 -5C ~ 48C -20C ~ 16C DC INV Rotary 1 BLDC BLDC motor 110 54 950x1,380x330 106 R410A 3.0 EEV FVC68D 1,300 1 / 220-240 / 50 2C x 1.0 ~ 1.5 300 150(175) 40 50(40) 15 9.52(3/8) 19.05(3/4) 1 9 50 ~ 130% Wide Louver plus fin

HP
Model
Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas Max Max Max Max Max

4
Combination unit
Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type Cooling Nom Nom Max Nom Nom Max kW kW kW kW kW kW

5
ARUN50LS2A
14.0 16.0 14.6 3.5 3.9 4.76 4.00 4.10 -5C ~ 48C -20C ~ 16C DC INV Rotary 1 BLDC BLDC motor 110 53 950x1,380x330 107 R410A 3.0 EEV FVC68D 1,300 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150(175) 40 50(40) 15 9.52(3/8) 15.88(5/8) 1 8 50 ~ 130% Wide Louver plus fin

6
ARUN60LS2A
15.5 18.0 16.4 4.2 4.6 5.61 3.69 3.91 -5C ~ 48C -20C ~ 16C DC INV Rotary 1 BLDC BLDC motor 110 54 950x1,380x330 107 R410A 3.0 EEV FVC68D 1,300 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150(175) 40 50(40) 15 9.52(3/8) 19.05(3/4) 1 9 50 ~ 130% Wide Louver plus fin

ARUN40GS2A
12.1 12.5 11.4 3.2 3.2 3.90 3.78 3.91

ARUN40LS2A
12.1 12.5 11.4 2.8 2.9 3.17 4.32 4.31

Min~Max C DB Min~Max C WB

-5C ~ 48C -20C ~ 16C DC INV Rotary 1 BLDC BLDC motor

Min~Max C DB Min~Max C WB

-5C ~ 48C -20C ~ 16C DC INV Rotary 1 BLDC BLDC motor

Max Max WxHxD

m /min dBA mm kg
3

60 52 950x834x330 77 R410A 1.8 EEV FVC68D

Max Max WxHxD

m3/min dBA mm kg kg

110 52 950x1,380x330 107 R410A 3.0 EEV FVC68D

Type Charge Control Type Control

kg

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

1,300 1 / 220-240 / 50 2C x 1.0 ~ 1.5 300 150(175) 40 50(40) 15 9.52(3/8) 15.88(5/8) 1 6 50 ~ 130% Wide Louver plus fin

Type Charge Control Type Control

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

1,300 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150(175) 40 50(40) 15 9.52(3/8) 15.88(5/8) 1 6 50 ~ 130% Wide Louver plus fin

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type Note :
1. Capacities are based on the following conditions

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type Note :
1. Capacities are based on the following conditions

Max Min-Max

Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m Interconnecting piping length 7.5m Level difference of zero Level difference of zero 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m Interconnecting piping length 7.5m Level difference of zero Level difference of zero 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

62

63

Heat pump
Outdoor Unit_MULTI V

HP
Model
Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas Max Max Max Max Max

6
Combination unit
Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type External Static pressure Cooling Nom Nom Max Nom Nom Max kW kW kW kW kW kW

HP
Model
Capacity Low Temperature Capacity Power Input Low Temperature Power Input COP Operation Range Compressor Fan Airflow Rate Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas Max Max Max Max Max

8
Combination unit
Cooling Heating Heating -7C Cooling Heating Heating -7C Cooling Heating Cooling Heating Type Number of Compressor Type Motor Type External Static pressure Cooling Nom Nom Max Nom Nom Max kW kW kW kW kW kW

ARUN60LL2(R2)
16.0 18.0 16.4 4.7 4.9 6.0 3.40 3.67

ARUN80LL2(R2)
21.7 23.0 20.9 6.7 7.1 8.7 3.24 3.24

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C DC Scroll 1 Sirocco BLDC motor

Min~Max C DB Min~Max C WB

-5C ~ 43C -20C ~ 16C DC Scroll 1 Sirocco BLDC motor

Max Max WxHxD

Pa m3/min dBA mm kg g

100 62 750 x 1,790 x 650 200 R410A 5.2 EEV FVC68D(PVE)

Max Max WxHxD

Pa m3/min dBA mm kg g

120 65 750 x 1,790 x 650 200 R410A 6.4 EEV FVC68D(PVE)

Type Charge Control Type Control

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

2300 3 / 380-415 / 50 CVV-SB 2C x 1.0~1.5 300 150(175) 40 50(40) 15 9.52(3/8) 19.05(3/4) 1 9 50 ~ 130% LG Louver Fin

Type Charge Control Type Control

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

2300 3 / 380-415 / 50 CVV-SB 2C x 1.0~1.5 300 150(175) 40 50(40) 15 9.52(3/8) 19.05(5/8) 1 13 50 ~ 130% Wide Louver plus fin

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type Note :
1. Capacities are based on the following conditions

Max Min-Max

Number of Outdoor Units Number of Connectable Indoor Units *** Ratio of the Connectable Indoor Units Heat exchanger Type Note :
1. Capacities are based on the following conditions

Max Min-Max

Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m Interconnecting piping length 7.5m Level difference of zero Level difference of zero 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve * ( ) : equivalent length

Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m Interconnecting piping length 7.5m Level difference of zero Level difference of zero 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve * ( ) : equivalent length

64

65

Heat pump
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

8
ARWN80LA2 ARWN80LA2

10
ARWN100LA2 ARWN100LA2

HP
Model Combination unit Independent unit

16
ARWN160LA2 ARWN160LA2

18
ARWN180LA2 ARWN180LA2

20
ARWN200LA2 ARWN200LA2

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Cooling Heating

Nom Nom Nom Nom

kW kW kW kW

22.4 25.2 4.5 4.7 5.0 5.4

28.0 31.5 5.6 5.8 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 1 51 772 x 1,120 x 547 154 R410A 7.3 EEV FVC68D(PVE) 2,32510 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 9.52(3/8) 22.2(7/8) 1 16 50 ~ 200% Stainless Steel Plate 45 96 26.5 PT32 PT32 20

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Cooling Heating

Nom Nom Nom Nom

kW kW kW kW

44.8 50.4 8.9 9.3 5.0 5.4

50.4 56.7 10.1 10.5 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x1+(Constant)x1 51 772 x 1,120 x 547 223 R410A 8.8 EEV FVC68D(PVE) (2,32510) + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 12.7(1/2) 28.58(1 1/8) 1 29 50 ~ 200% Stainless Steel Plate 45 175 43 PT40 PT40 20

56.0 63.0 11.2 11.7 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x1+(Constant)x1 51 772 x 1,120 x 547 223 R410A 8.8 EEV FVC68D(PVE) (2,32510) + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 12.7(1/2) 28.58(1 1/8) 1 32 50 ~ 200% Stainless Steel Plate 45 192 43 PT40 PT40 20

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 1

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x1+(Constant)x1

Max WxHxD Type Charge Control Type Control

dBA mm kg g

51 772 x 1,120 x 547 154 R410A 7.3 EEV FVC68D(PVE)

Max WxHxD Type Charge Control Type Control

dBA mm kg g

51 772 x 1,120 x 547 223 R410A 8.8 EEV FVC68D(PVE)

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

2,32510 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 9.52(3/8) 22.2(7/8) 1 13 50 ~ 200% Stainless Steel Plate

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

(2,32510) + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 12.7(1/2) 28.58(1 1/8) 1 26 50 ~ 200% Stainless Steel Plate

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

45 80 26.5 PT32 PT32 20

45 155 43 PT40 PT40 20

Water Connection pipe Notes:

Water Connection pipe Notes:

1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

66

67

Heat pump
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

24
ARWN240LA2 ARWN80LA2 ARWN160LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
67.2 75.6 13.4 14.0 5.0 5.4

26
ARWN260LA2 ARWN100LA2 ARWN160LA2
72.8 81.9 14.6 15.2 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 1 53 (772 x 1,120 x 547) x 2 223 + 154 R410A 7.3 + 8.8 EEV FVC68D(PVE) (2,32510) x 2 + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 34.9(1 3/8) 2 42 50 ~ 160% Stainless Steel Plate 45 155 + 96 43.0 + 26.5 PT40 + PT32 PT40 + PT32 20

HP
Model Combination unit Independent unit

28
ARWN280LA2 ARWN100LA2 ARWN180LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
78.4 88.2 15.7 16.4 5.0 5.4

30
ARWN300LA2 ARWN100LA2 ARWN200LA2
84.0 94.5 16.8 17.5 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 1 53 (772 x 1,120 x 547) x 2 223 + 154 R410A 7.3 + 8.8 EEV FVC68D(PVE) (2,32510) x 2 + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 34.9(1 3/8) 2 48 50 ~ 160% Stainless Steel Plate 45 192 + 96 43.0 + 26.5 PT40 + PT32 PT40 + PT32 20

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 1

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 1

Max WxHxD Type Charge Control Type Control

dBA mm kg g

53 (772 x 1,120 x 547) x 2 223 + 154 R410A 7.3 + 8.8 EEV FVC68D(PVE)

Max WxHxD Type Charge Control Type Control

dBA mm kg g

53 (772 x 1,120 x 547) x 2 223 + 154 R410A 7.3 + 8.8 EEV FVC68D(PVE)

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

(2,32510) x 2 + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 34.9(1 3/8) 1 39 50 ~ 200% Stainless Steel Plate

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

(2,32510) x 2 + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 34.9(1 3/8) 2 45 50 ~ 160% Stainless Steel Plate

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

45 155 + 80 43.0 + 26.5 PT40 + PT32 PT40 + PT32 20

45 175 + 96 43.0 + 26.5 PT40 + PT32 PT40 + PT32 20

Water Connection pipe Notes:

Water Connection pipe Notes:

1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

68

69

Heat pump
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

32
ARWN320LA2 ARWN160LA2 ARWN160LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
89.6 100.8 17.8 18.6 5.0 5.4

34
ARWN340LA2 ARWN160LA2 ARWN180LA2
95.2 107.1 19.0 19.8 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 2 54 (772 x 1,120 x 547) x 2 223 + 223 R410A 8.8 + 8.8 EEV FVC68D(PVE) (2,32510) x 2 + (2,32570) x 2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 2 55 50 ~ 160% Stainless Steel Plate 45 155 + 175 43.0 + 43.0 PT40 + PT40 PT40 + PT40 20

HP
Model Combination unit Independent unit

36
ARWN360LA2 ARWN180LA2 ARWN180LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
100.8 113.4 20.2 21.0 5.0 5.4

38
ARWN380LA2 ARWN180LA2 ARWN200LA2
106.4 119.7 21.3 22.2 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x2+(Constant)x2 54 (772 x 1,120 x 547) x 2 223 + 223 R410A 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x2+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 2 61 50 ~ 160% Stainless Steel Plate 45 192 + 175 43.0 + 43.0 PT40 + PT40 PT40 + PT40 20

40
ARWN400LA2 ARWN200LA2 ARWN200LA2
112.0 126.0 22.4 23.4 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x2+(Constant)x2 54 (772 x 1,120 x 547) x 2 223 + 223 R410A 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x2+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 2 64 50 ~ 160% Stainless Steel Plate 45 192 + 192 43.0 + 43.0 PT40 + PT40 PT40 + PT40 20

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 2

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x2+(Constant)x2

Max WxHxD Type Charge Control Type Control

dBA mm kg g

54 (772 x 1,120 x 547) x 2 223 + 223 R410A 8.8 + 8.8 EEV FVC68D(PVE)

Max WxHxD Type Charge Control Type Control

dBA mm kg g

54 (772 x 1,120 x 547) x 2 223 + 223 R410A 8.8 + 8.8 EEV FVC68D(PVE)

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

(2,32510) x 2 + (2,32570) x 2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 2 52 50 ~ 160% Stainless Steel Plate

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

(2,32510)x2+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 2 58 50 ~ 160% Stainless Steel Plate

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

45 155 + 155 43.0 + 43.0 PT40 + PT40 PT40 + PT40 20

45 175 + 175 43.0 + 43.0 PT40 + PT40 PT40 + PT40 20

Water Connection pipe Notes:

Water Connection pipe Notes:

1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

70

71

Heat pump
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

42
ARWN420LA2 ARWN100LA2 ARWN160LA2 ARWN160LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
117.6 132.3 23.4 24.4 5.0 5.4

44
ARWN440LA2 ARWN100LA2 ARWN160LA2 ARWN180LA2
123.2 138.6 24.6 25.6 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+(Constant)x2 55 (772 x 1,120 x 547) x 3 223 + 223 + 154 R410A 7.3 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x3+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 96 43.0 + 43.0 + 26.5 PT40 + PT40 + PT32 PT40 + PT40 + PT32 20

46
ARWN460LA2 ARWN100LA2 ARWN180LA2 ARWN180LA2
128.8 144.9 25.8 26.8 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+(Constant)x2 55 (772 x 1,120 x 547) x 3 223 + 223 + 154 R410A 7.3 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x3+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 96 43.0 + 43.0 + 26.5 PT40 + PT40 + PT32 PT40 + PT40 + PT32 20

HP
Model Combination unit Independent unit

48
ARWN480LA2 ARWN100LA2 ARWN180LA2 ARWN200LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
134.4 151.2 26.9 28.0 5.0 5.4

50
ARWN500LA2 ARWN100LA2 ARWN100LA2 ARWN200LA2
140.0 157.5 28.0 29.2 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+(Constant)x2 55 (772 x 1,120 x 547) x 3 223 + 223 + 154 R410A 7.3 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x3+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 96 43.0 + 43.0 + 26.5 PT40 + PT40 + PT32 PT40 + PT40 + PT32 20

52
ARWN520LA2 ARWN160LA2 ARWN180LA2 ARWN180LA2
145.6 163.8 29.1 30.3 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+(Constant)x3 56 (772 x 1,120 x 547) x 3 223 + 223 + 223 R410A 8.8 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x3+(2,32570)x3 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 192 43.0 + 43.0 + 43.0 PT40 + PT40 + PT40 PT40 + PT40 + PT40 20

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+(Constant)x2

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+(Constant)x2

Max WxHxD Type Charge Control Type Control

dBA mm kg g

55 (772 x 1,120 x 547) x 3 223 + 223 + 154 R410A 7.3 + 8.8 + 8.8 EEV FVC68D(PVE)

Max WxHxD Type Charge Control Type Control

dBA mm kg g

55 (772 x 1,120 x 547) x 3 223 + 223 + 154 R410A 7.3 + 8.8 + 8.8 EEV FVC68D(PVE)

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

(2,32510)x3+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Stainless Steel Plate

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

(2,32510)x3+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Stainless Steel Plate

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

45 192 + 192 + 96 43.0 + 43.0 + 26.5 PT40 + PT40 + PT32 PT40 + PT40 + PT32 20

45 192 + 192 + 96 43.0 + 43.0 + 26.5 PT40 + PT40 + PT32 PT40 + PT40 + PT32 20

Water Connection pipe Notes:

Water Connection pipe Notes:

1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

72

73

Heat pump
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

54
ARWN540LA2 ARWN160LA2 ARWN180LA2 ARWN200LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
151.2 170.1 30.2 31.5 5.0 5.4

56
ARWN560LA2 ARWN180LA2 ARWN180LA2 ARWN200LA2
156.8 176.4 31.4 32.7 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 3 + (Constant) x 3 56 (772 x 1,120 x 547) x 3 223 + 223 + 223 R410A 8.8 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510) x 3 + (2,32570) x 3 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 192 43.0 + 43.0 + 43.0 PT40 + PT40 + PT40 PT40 + PT40 + PT40 20

HP
Model Combination unit Independent unit

58
ARWN580LA2 ARWN180LA2 ARWN200LA2 ARWN200LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
162.4 182.7 32.5 33.9 5.0 5.4

60
ARWN600LA2 ARWN200LA2 ARWN200LA2 ARWN200LA2
168.0 189.0 33.6 35.1 5.0 5.4 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 3 + (Constant) x 3 56 (772 x 1,120 x 547) x 3 223 + 223 + 223 R410A 8.8 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510) x 3 + (2,32570) x 3 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 192 43.0 + 43.0 + 43.0 PT40 + PT40 + PT40 PT40 + PT40 + PT40 20

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 3 + (Constant) x 3

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 3 + (Constant) x 3

Max WxHxD Type Charge Control Type Control

dBA mm kg g

56 (772 x 1,120 x 547) x 3 223 + 223 + 223 R410A 8.8 + 8.8 + 8.8 EEV FVC68D(PVE)

Max WxHxD Type Charge Control Type Control

dBA mm kg g

56 (772 x 1,120 x 547) x 3 223 + 223 + 223 R410A 8.8 + 8.8 + 8.8 EEV FVC68D(PVE)

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

(2,32510) x 3 + (2,32570) x 3 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Stainless Steel Plate

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch)

(2,32510) x 3 + (2,32570) x 3 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.05(3/4) 41.3(1 5/8) 3 64 50 ~ 130% Stainless Steel Plate

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

45 192 + 192 + 192 43.0 + 43.0 + 43.0 PT40 + PT40 + PT40 PT40 + PT40 + PT40 20

45 192 + 192 + 192 43.0 + 43.0 + 43.0 PT40 + PT40 + PT40 PT40 + PT40 + PT40 20

Water Connection pipe Notes:

Water Connection pipe Notes:

1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

74

75

Heat Recovery
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

8
ARWB80LA2 ARWB80LA2

10
ARWB100LA2 ARWB100LA2

HP
Model Combination unit Independent unit

16
ARWB160LA2 ARWB160LA2

18
ARWB180LA2 ARWB180LA2

20
ARWB200LA2 ARWB200LA2

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Cooling Heating

Nom Nom Nom Nom

kW kW kW kW

22.4 25.2 4.5 4.7 4.98 5.36

28 31.5 5.6 5.8 5.00 5.43 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 1 51 772 x 1,120 x 547 154 R410A 7.3 EEV FVC68D(PVE) 2,32510 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 9.52(3/8) 22.2(7/8) 19.1(3/4) 1 16 50 ~ 200% Stainless Steel Plate 45 96 26.5 PT32 PT32 20

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Cooling Heating

Nom Nom Nom Nom

kW kW kW kW

44.8 50.4 8.9 9.3 5.03 5.42

50.4 56.7 10.1 10.5 4.99 5.40 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x1+(Constant)x1 51 772 x 1,120 x 547 223 R410A 8.8 EEV FVC68D(PVE) (2,32510) + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 12.7(1/2) 28.6(1 1/8) 22.2(7/8) 1 29 50 ~ 200% Stainless Steel Plate 45 175 43 PT40 PT40 20

56 63 11.2 11.7 5.00 5.38 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x1+(Constant)x1 51 772 x 1,120 x 547 223 R410A 8.8 EEV FVC68D(PVE) (2,32510) + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 12.7(1/2) 28.58(1 1/8) 22.2(7/8) 1 32 50 ~ 200% Stainless Steel Plate 45 192 43 PT40 PT40 20

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 1

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x1+(Constant)x1

Max WxHxD Type Charge Control Type Control

dBA mm kg g

51 772 x 1,120 x 547 154 R410A 7.3 EEV FVC68D(PVE)

Max WxHxD Type Charge Control Type Control

dBA mm kg g

51 772 x 1,120 x 547 223 R410A 8.8 EEV FVC68D(PVE)

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas High Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

2,32510 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 9.52(3/8) 22.2(7/8) 19.1(3/4) 1 13 50 ~ 200% Stainless Steel Plate

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas High Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

(2,32510) + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 12.7(1/2) 28.6(1 1/8) 22.2(7/8) 1 26 50 ~ 200% Stainless Steel Plate

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

45 80 26.5 PT32 PT32 20

45 155 43 PT40 PT40 20

Water Connection pipe

Water Connection pipe

Notes:
1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

Notes:
1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

76

77

Heat Recovery
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

24
ARWB240LA2 ARWB80LA2 ARWB160LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
67.2 75.6 13.4 14 5.01 5.40

26
ARWB260LA2 ARWB100LA2 ARWB160LA2
72.8 81.9 14.6 15.2 4.99 5.39 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 1 53 (772 x 1,120 x 547) x 2 223 + 154 R410A 7.3 + 8.8 EEV FVC68D(PVE) (2,32510) x 2 + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 34.9(1 3/8) 28.6(1 1/8) 2 42 50 ~ 160% Stainless Steel Plate 45 155 + 96 43.0 + 26.5 PT40 + PT32 PT40 + PT32 20

HP
Model Combination unit Independent unit

28
ARWB280LA2 ARWB100LA2 ARWB180LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
78.4 88.2 15.7 16.4 4.99 5.38

30
ARWB300LA2 ARWB100LA2 ARWB200LA2
84 94.5 16.8 17.5 5.00 5.40 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 1 53 (772 x 1,120 x 547) x 2 223 + 154 R410A 7.3 + 8.8 EEV FVC68D(PVE) (2,32510) x 2 + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 34.9(1 3/8) 28.6(1 1/8) 2 48 50 ~ 160% Stainless Steel Plate 45 192 + 96 43.0 + 26.5 PT40 + PT32 PT40 + PT32 20

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 1

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 1

Max WxHxD Type Charge Control Type Control

dBA mm kg g

53 (772 x 1,120 x 547) x 2 223 + 154 R410A 7.3 + 8.8 EEV FVC68D(PVE)

Max WxHxD Type Charge Control Type Control

dBA mm kg g

53 (772 x 1,120 x 547) x 2 223 + 154 R410A 7.3 + 8.8 EEV FVC68D(PVE)

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas High Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

(2,32510) x 2 + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 34.9(1 3/8) 28.6(1 1/8) 1 39 50 ~ 200% Stainless Steel Plate

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas High Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

(2,32510) x 2 + (2,32570) 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 34.9(1 3/8) 28.6(1 1/8) 2 45 50 ~ 160% Stainless Steel Plate

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

45 155 + 80 43.0 + 26.5 PT40 + PT32 PT40 + PT32 20

45 175 + 96 43.0 + 26.5 PT40 + PT32 PT40 + PT32 20

Water Connection pipe

Water Connection pipe

Notes:
1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

Notes:
1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

78

79

Heat Recovery
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

32
ARWB320LA2 ARWB160LA2 ARWB160LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
89.6 100.8 17.8 18.6 5.03 5.42

34
ARWB340LA2 ARWB160LA2 ARWB180LA2
95.2 107.1 19 19.8 5.01 5.41 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 2 54 (772 x 1,120 x 547) x 2 223 + 223 R410A 8.8 + 8.8 EEV FVC68D(PVE) (2,32510) x 2 + (2,32570) x 2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 2 55 50 ~ 160% Stainless Steel Plate 45 155 + 175 43.0 + 43.0 PT40 + PT40 PT40 + PT40 20

HP
Model Combination unit Independent unit

36
ARWB360LA2 ARWB180LA2 ARWB180LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
100.8 113.4 20.2 21 4.99 5.40

38
ARWB380LA2 ARWB180LA2 ARWB200LA2
106.4 119.7 21.3 22.2 5.00 5.39 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x2+(Constant)x2 54 (772 x 1,120 x 547) x 2 223 + 223 R410A 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x2+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 2 61 50 ~ 160% Stainless Steel Plate 45 192 + 175 43.0 + 43.0 PT40 + PT40 PT40 + PT40 20

40
ARWB400LA2 ARWB200LA2 ARWB200LA2
112 126 22.4 23.4 5.00 5.38 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x2+(Constant)x2 54 (772 x 1,120 x 547) x 2 223 + 223 R410A 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x2+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 2 64 50 ~ 160% Stainless Steel Plate 45 192 + 192 43.0 + 43.0 PT40 + PT40 PT40 + PT40 20

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 2 + (Constant) x 2

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x2+(Constant)x2

Max WxHxD Type Charge Control Type Control

dBA mm kg g

54 (772 x 1,120 x 547) x 2 223 + 223 R410A 8.8 + 8.8 EEV FVC68D(PVE)

Max WxHxD Type Charge Control Type Control

dBA mm kg g

54 (772 x 1,120 x 547) x 2 223 + 223 R410A 8.8 + 8.8 EEV FVC68D(PVE)

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas High Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

(2,32510) x 2 + (2,32570) x 2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 2 52 50 ~ 160% Stainless Steel Plate

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas High Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

(2,32510)x2+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 2 58 50 ~ 160% Stainless Steel Plate

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

45 155 + 155 43.0 + 43.0 PT40 + PT40 PT40 + PT40 20

45 175 + 175 43.0 + 43.0 PT40 + PT40 PT40 + PT40 20

Water Connection pipe

Water Connection pipe

Notes:
1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

Notes:
1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

80

81

Heat Recovery
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

42
ARWB420LA2 ARWB100LA2 ARWB160LA2 ARWB160LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
117.6 132.3 23.4 24.4 5.03 5.42

44
ARWB440LA2 ARWB100LA2 ARWB160LA2 ARWB180LA2
123.2 138.6 24.6 25.6 5.01 5.41 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+(Constant)x2 55 (772 x 1,120 x 547) x 3 223 + 223 + 154 R410A 7.3 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x3+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 96 43.0 + 43.0 + 26.5 PT40 + PT40 + PT32 PT40 + PT40 + PT32 20

46
ARWB460LA2 ARWB100LA2 ARWB180LA2 ARWB180LA2
128.8 144.9 25.8 26.8 4.99 5.41 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+(Constant)x2 55 (772 x 1,120 x 547) x 3 223 + 223 + 154 R410A 7.3 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x3+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 96 43.0 + 43.0 + 26.5 PT40 + PT40 + PT32 PT40 + PT40 + PT32 20

HP
Model Combination unit Independent unit

48
ARWB480LA2 ARWB100LA2 ARWB180LA2 ARWB200LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
134.4 151.2 26.9 28 5.00 5.40

50
ARWB500LA2 ARWB100LA2 ARWB100LA2 ARWB200LA2
140 157.5 28 29.2 5.00 5.39 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+(Constant)x2 55 (772 x 1,120 x 547) x 3 223 + 223 + 154 R410A 7.3 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x3+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 96 43.0 + 43.0 + 26.5 PT40 + PT40 + PT32 PT40 + PT40 + PT32 20

52
ARWB520LA2 ARWB160LA2 ARWB180LA2 ARWB180LA2
145.6 163.8 29.1 30.3 5.00 5.41 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+(Constant)x3 56 (772 x 1,120 x 547) x 3 223 + 223 + 223 R410A 8.8 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510)x3+(2,32570)x3 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 192 43.0 + 43.0 + 43.0 PT40 + PT40 + PT40 PT40 + PT40 + PT40 20

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+(Constant)x2

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter)x3+ Constant)x2

Max WxHxD Type Charge Control Type Control

dBA mm kg g

55 (772 x 1,120 x 547) x 3 223 + 223 + 154 R410A 7.3 + 8.8 + 8.8 EEV FVC68D(PVE)

Max WxHxD Type Charge Control Type Control

dBA mm kg g

55 (772 x 1,120 x 547) x 3 223 + 223 + 154 R410A 7.3 + 8.8 + 8.8 EEV FVC68D(PVE)

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas High Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

(2,32510)x3+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Stainless Steel Plate

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas High Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

(2,32510)x3+(2,32570)x2 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Stainless Steel Plate

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

45 192 + 192 + 96 43.0 + 43.0 + 26.5 PT40 + PT40 + PT32 PT40 + PT40 + PT32 20

45 192 + 192 + 96 43.0 + 43.0 + 26.5 PT40 + PT40 + PT32 PT40 + PT40 + PT32 20

Water Connection pipe

Water Connection pipe

Notes:
1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

Notes:
1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

82

83

Heat Recovery
Outdoor Unit_MULTI V

HP
Model Combination unit Independent unit

54
ARWB540LA2 ARWB160LA2 ARWB180LA2 ARWB200LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
151.2 170.1 30.2 31.5 5.01 5.40

56
ARWB560LA2 ARWB180LA2 ARWB180LA2 ARWB200LA2
156.8 176.4 31.4 32.7 4.99 5.39 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 3 + (Constant) x 3 56 (772 x 1,120 x 547) x 3 223 + 223 + 223 R410A 8.8 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510) x 3 + (2,32570) x 3 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 192 43.0 + 43.0 + 43.0 PT40 + PT40 + PT40 PT40 + PT40 + PT40 20

HP
Model Combination unit Independent unit

58
ARWB580LA2 ARWB180LA2 ARWB200LA2 ARWB200LA2
Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW kW kW
162.4 182.7 32.5 33.9 5.00 5.39

60
ARWB600LA2 ARWB200LA2 ARWB200LA2 ARWB200LA2
168 189 33.6 35.1 5.00 5.38 10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 3 + (Constant) x 3 56 (772 x 1,120 x 547) x 3 223 + 223 + 223 R410A 8.8 + 8.8 + 8.8 EEV FVC68D(PVE) (2,32510) x 3 + (2,32570) x 3 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Stainless Steel Plate 45 192 + 192 + 192 43.0 + 43.0 + 43.0 PT40 + PT40 + PT40 PT40 + PT40 + PT40 20

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Capacity Power Input EER COP Operation Range Compressor Sound Pressure Dimensions Net Weight Refrigerant Refrigerant Oil Power Supply Transmission Cable (VCTF-SB) Piping Length Piping Level Difference Piping Connection Number of Outdoor Units Number of Connectable Indoor Units Ratio of the Connectable Indoor Units Heat Exchanger

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 3 + (Constant) x 3

Cooling Heating Type Number of Compressor

Min~Max C DB Min~Max C WB

10C ~ 45C -5C ~ 45C Hermetic Scroll (Inverter) x 3 + (Constant) x 3

Max WxHxD Type Charge Control Type Control

dBA mm kg g

56 (772 x 1,120 x 547) x 3 223 + 223 + 223 R410A 8.8 + 8.8 + 8.8 EEV FVC68D(PVE)

Max WxHxD Type Charge Control Type Control

dBA mm kg g

56 (772 x 1,120 x 547) x 3 223 + 223 + 223 R410A 8.8 + 8.8 + 8.8 EEV FVC68D(PVE)

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas High Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

(2,32510) x 3 + (2,32570) x 3 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Stainless Steel Plate

Total Actual Longest Piping Length * After 1st Y branch ** IDU-ODU IDU-IDU Liquid Low Pressure Gas High Pressure Gas

Max Max Max Max Max

cc /V/Hz No. x mm m m m m m mm(inch) mm(inch) mm(inch)

(2,32510) x 3 + (2,32570) x 3 3 / 380-415 / 50 2C x 1.0 ~ 1.5 300 150 40 50 15 19.1(3/4) 41.3(1 5/8) 34.9(1 3/8) 3 64 50 ~ 130% Stainless Steel Plate

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

Max Min-Max Type Pressure Resistance Nom Water Flow Head Loss Inlet Outlet Drain Outlet Max kgf/cm L/min kPa mm(inch) mm(inch) mm

45 192 + 192 + 192 43.0 + 43.0 + 43.0 PT40 + PT40 + PT40 PT40 + PT40 + PT40 20

45 192 + 192 + 192 43.0 + 43.0 + 43.0 PT40 + PT40 + PT40 PT40 + PT40 + PT40 20

Water Connection pipe

Water Connection pipe

Notes:
1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

Notes:
1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27C [80.6F]DB/19C[66.2F]WB, Water inlet temp. 30C[86F], Interconnecting piping length 7.5m, Level difference of zero Heating : - Indoor temp. 20C[68F]DB - Water inlet temp. 20C[68F] 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without notification 4. EEV : Electronic Expansion Valve 5. Add an anti freeze to circulation water when outside units is operating undet 10C [50F], and change the DIP switch on main PCB.(For more information oninstallation section.) * ( ) : equivalent length ** ( ) : In case of outdoor unit installed lower than indoor unit.

84

85

If you need a highly efficient air conditioning system in your building, MULTI V is the right choice for you.

86

98 100 101 102 104 108 114 116 117 118

ARTCOOL

INdoor unit

Standard

Wall mounted

Console

Ceiling cassette

Ceiling Concealed duct Fresh air intake unit

Ceiling & Floor

Ceiling Suspended

Floor standing

Wall mounted Artcool (Gallery / Panel / Mirror)


Aesthetic Design
You no longer need to be told what your air conditioner should look like. With LGs revolutionary ARTCOOL Gallery, you can change the look of your air conditioner to whatever you want, whenever you want. The ARTCOOL series have outstanding designs and have been awarded the International Forum Design Award, the Reddot Design Award and the G Mark. How to Change the Picture

Standard
Installation Support Clip
A support clip creates adequate space between the wall and the unit for easier installation.

Indoor Unit_MULTI V

25

Wider Piping Space

165mm The tubing space is up to 45% wider than previous models for easier installation. The tubing space is wider than many products currently on the market.

Conventional Panel Type ARTCOOL Mirror

LG

100% Mirror Silver


07/09/12GSFV2

145%

Silver
07/09/12/15GSEV2 18/24GS8V2

Gold
07/09/12GSFG2

07/09/12/15GSER2 18/24GS8R2

Auto Cleaning
A major cause of air conditioner odours is mould and bacteria that can breed in the heat exchanger. The auto clean function dries the wet heat exchanger to prevent mould and bacteria from breeding which can significantly reduce smells and saves the user from frequent cleaning.

* * *

Red
07/09/12GSFE2

White silver
07/09/12GSFH2
*

Digital Air Flow Control


The air flow can be controlled to ensure maximum comfort and convenience.

Interior of air conditioner dried out automatically after use

Ion sterilisation function removes germs and mould

Conventional VS Auto Cleaning


Conventional
The main causes of odour within air conditioners is mould and bacteria in the heat exchanger, which breeds when the heat exchanger is wet.

Auto Cleaning
The automatic cleaning function dries the wet heat exchanger to prevent the bacteria from breeding mould. It eliminates the odour from air conditioners and can reduce the hassle of having to frequently clean the filter.

Normal
Fast, wide and even

Jet cool
Speedy and powerful

Sleep mode
Indirect and discreet

88

89

Standard
Low Noise Level
The indoor unit operates quietly in sleep mode for peace and quiet for in bedroom or office. For example, LG model ARNU09GSBL2, ARNU12GSBL2 in sleep mode is only 19dB. In addition, the outdoor units have reduced vibration and noise thanks to a super quiet fan and motor.
Conventional Fan
When the fan rotates, the stabilser and the fan blade are in parallel (= the contact of lines)

Console
Optimised Air Flow for Cooling & Heating
During the cooling operation, the vane adjusts upwards to direct the air flow towards the ceiling. When heating, the vane directs the warm air downwards to balance the room temperature especially for floor.

Indoor Unit_MULTI V

Skew Fan

22dB

Stabilizer

Fan rotates

Instantaneous pressure change is great.

Stabilizer

Fan rotates

When the fan rotates, the stabilser and the fan blade are not in parallel (= the contact of points)

3dB
19dB

Instantaneous pressure change is small.

Cooling

Heating (Normal)

Heating (Floor Heating Mode)

Conventional

LG

Quick Floor Heating


Console air conditioners offer a fast and powerful performance. Using the floor heating mode, console air conditioners provide faster floor heating and help to reach the desired temperature quickly.
Company A
27C
t 26 25 24 23 22 21 20 19 18

Electric Heater

LG

Floor Heating Mode

LG

Deodorising (Triple filter)


The triple filter consists of three special filters that can reduce the side effects caused by some organic compounds including formaldehyde. It has the ability to remove unpleasant odours and can create a more comfortable environment.

Vertical

Horizontal

15C

1 VOC filter removes odour and hazardous VOCs that are discharged from household materials made out of chemical substances (carpet, paint, cleaners, furniture, etc.) (VOC= Volatile Organic Chemical) 2 Formaldehyde filter removes formaldehyde, a leading cause of sick building syndrome, and can prevent dermatitis, vomiting, and pneumonia 3 Common odour filter removes ordinary odours that can cause migraines and chronic fatigue syndrome

Lead Time for Heating (13C 21C)

12 minutes 9 minutes 8 minutes 50 minutes 30 seconds 30 seconds 40 seconds

(Test Condition :Target Temp 23C, Indoor Room:13C~ , Outdoor Room:7C)

5-Step Vane Control


There are 5 different stages to control air flow direction.
3step 4step 1step 2step

5step

Eliminating Plasma Filter


The plasma air purifying system was initially developed by LG not only for reduction of microscopic contaminants and dust, but also for the removal of house mites, small dust particles, and pet fur in order to reduce allergy and asthma symptoms.

Healthy Air with 3-stage Air Filter System


1st Advanced Pre Filter : The antibacterial pre-filter primarily reduces large dust particles and mould.

Odor Dust Particles


Polluted Air Ionising Dust Charging (+) Odour Decomposition Filtering Filtering of Dust by Coulomb Force

2nd Allergy Filter Filter consist of enzyme that breaks down allergen, apatite and organic/inorganic binder. When the air passes the filter, allergen clings to the filter, and the filter cut allergen like tiny pairs of scissors.

Clean Air
Deodorising Deodorisation

3rd Plasma Ion Generator The sterilized ion generator emits around 1.2 million ions, and catches hazardous substances floating in the air.

90

91

Ceiling Cassette
Independent vane control
It is possible to control each of the 4 vanes individually as the motors are connected separately to each vane.
All vane operation Individual vane angle control

Flexible Connection
Flexible connection of remote controller - Group control : 1 remote controller up to 16 indoor units. - Second remote control : 2 remote controllers to 1 indoor unit Easy & solid attachment to the wall

Indoor Unit_MULTI V

wall

wall

Auto Elevation Grille


Easy filter cleaning with elevation grill - Installation inside main body - Auto horizontal control - 4 points support structure - Memory for users level - Max 4.5m length - Model : PTEGM0
4-Point support structure Auto Leveling Memory for users level Auto Stop Detection
Max. 4.5m

Direct air flow

Indirect air flow

Swirl Swing
Swirl swing distributes air evenly throughout the room to ensure a more comfortable environment by adjusting the movement of the vane. Comparison of temperatures
Attachable/detachable corner design Refrigant Piping check Drain leakage check

Attachable/detachable corner design


Swirl swing (plaesant air)

Refrigant Piping check

Normal air flow

STOP Memory

* Operating with wired remote controller PQRCVSL0(QW) and wireless remote controller included in PTEGM0. * Except ARNU05GTRC2, ARNU07GTRC2, ARNU09GTRC2, ARNU12GTRC2, ARNU15GTQC2, ARNU18GTQC2

Attachable/detachable Hanger adjust corner design Refrigant Piping check Drain leakage check

Vertical Temp. differences


Hanger adjust

Horizontal Temp. differences

Hanger adjust

High Ceiling Mode


High ceiling mode provides powerful cooling and heating up to 4.2m in height, from ceiling to floor.

Compact Size
The indoor unit with slim and compact dimensions has Detachable Corner Design reduced the restriction which enables successful installation Hanger adjust in various spaces.
Refrigant 6.0~7.2 kW Piping check
conventional
218mm

Convenient Panel Installation


Detachable Corner Design

The detachable corner design makes it easy to adjust the hanger during installation and to check for leakages in the drain connection pipe.
Hanger adjust Drain leakage check

Drain leakage check

8.3~11.0 kW
288mm

4.2m
Refrigant Piping check

LG 204mm Detachable Corner Design Hanger adjust

246mm
Hanger adjust Drain leakage check

Refrigerant piping check and Hanger adjust


Hanger adjust Drain Leakage Check

Drain leakage check and hanger adjust

Hanger Adjust

Hanger adjust

Hanger adjust

Drain Leakage

Hanger adjust

Hanger adjust

Drain Leakage Check

Hanger Adjust
93

92

Ceiling Concealed Duct


Operation for Multiple Rooms
Using a spiral duct (embedded or flexible type) and stream chamber, it is possible to operate cooling/heating for several rooms simultaneously.

Variable E.S.P. with Low Noise (Low Static Duct Only)


The E.S.P. of the new low static ducts can be easily controlled by the wired remote controller(0~50Pa). It allows the external static pressure to be finely tuned according to the application. In addition, the noise levels have been reduced, in spite of the increase in the maximum E.S.P.

Indoor Unit_MULTI V

Flexible Installation (Low Static Duct Only) Two Thermistors Control


The indoor temperature can be checked using the thermistors in the remote controller as well as from the indoor unit. There may be a significant difference between ceiling and floor air temperature. Two thermistors can optimise indoor air temperature for a more comfortable environment.
Compares temperatures sensed from different positions, and automatically selects the optimum temperature for users
Indoor Unit Thermistor

The new low static duct allows you to choose the air intake direction.(Back or underneath) Conventional low static duct Models only take return air from the back, this means which needs more space is needed for ducting. It is suitable for applications which dont have enough space.

Conventional

New

< Only back Side >


Remote Controller Thermistor

< Bottom >

< Back >

Easy Servicing and Maintenance (Low Static Duct Only)


The drain pump is installed on the surface of the product, which is detachable. Users can detach the drain pump for more convenient servicing and natural drainage.

E.S.P. Control
The BLDC motor and low noise fan means that air volume can be easily controlled by using the wired remote controller. The BLDC motor can control the fan speed and air volume regardless of the external static pressure(E.S.P.) With E.S.P control no additional accessories are needed to adjust the air flow and the energy consumption of the fan is also reduced.
Air Volume
L H M L M H

Available for natural drainage Detachable drain pump


2 4 6 8 10 12

External Static Pressure (mmAq)

94

95

Ceiling & Floor Ceiling Suspended


Flexible Installation
The ceiling and floor models can be installed either on the ceiling or on the floor. This saves space when installed in shops or offices.

Floor Standing
Block Cold Draft
The floor standing unit can block cold drafts from windows to provide a warmer environment for places such as libraries and offices.

Indoor Unit_MULTI V

Cold Draft Block cold drafts to provide a warmer environment


* Ceiling & Floor : ARNU09GVEA2, ARNU12GVEA2

Without Floor Standing

With Floor Standing

Airflow Direction Control


Horizontal Airflow Direction Control Adjust the horizontal airflow direction by manually moving the horizontal airflow direction loure by hand. Vertical Airflow Direction Control The airflow direction can be adjusted as desired by using the remote control.

3 way Flexible Installation


It is possible to install and connect the outdoor unit in 3 different ways (side, back, floor).

Sliding Type Filter


Easy maintenance and extended product life with sliding type filter

Horizontal

Vertical

One Touch Filter


The filter change alarm informs you when the unit has been operating for 2,400 hours. It is very easy to clean or change the filter.

Filter Alarm after 2400 hours of Unit working


model: VJ,VK,VL chassis
Filter Change Alarm

Back

Sliding type

Side

Floor

Filter

One touch Filter Easy cleaning

96

97

/ Panel

Mirror

ARNU07GSF*2 / ARNU09GSF*2 ARNU12GSF*2


* 1: Photo changeable - V : Silver - E : Red - G : Gold - H : White Silver

ARNU07GSE*2 / ARNU09GSE*2 ARNU12GSE*2 / ARNU15GSE*2 ARNU18GS8*2 / ARNU24GS8*2


- R : Mirror - V : Silver

Indoor Unit_MULTI V

Silver(V)

Gold(G)

Red(E)

White Silver(H)

Silver(V)

Model
Capacity Power Input Power Supply Airflow Rate Sound Pressure Dimensions Net Weight Cooling Heating Body H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU07GSF*2
2.2 2.5 35 35 1 / 220 ~ 240 / 50 8.1 / 6.3 / 4.2 8.1 / 6.3 / 4.2 38 / 32 / 27 600 x 600 x 146 15(33.1) 6.35(1/4) 12.7(1/2) 12.2(15/32)

ARNU09GSF*2
2.8 3.2 35 35 1 / 220 ~ 240 / 50 8.1 / 6.3 / 4.2 8.1 / 6.3 / 4.2 38 / 32 / 27 600 x 600 x 146 15(33.1) 6.35(1/4) 12.7(1/2) 12.2(15/32)

ARNU12GSF*2
3.6 4.0 35 35 1 / 220 ~ 240 / 50 9.3 / 7.7 / 6.0 9.3 / 7.7 / 6.0 44 / 38 / 32 600 x 600 x 146 15(33.1) 6.35(1/4) 12.7(1/2) 12.2(15/32)

Model
Capacity Power Input Power Supply Airflow Rate Sound Pressure Dimensions Net Weight Cooling Heating Body H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU07GSE*2
2.2 2.5 40 40 1 / 220 ~ 240 / 50 7.0 / 6.0 / 4.0 7.0 / 6.0 / 4.0 37 / 33 / 23 915 x 282 x 165 11.2(24.7) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU09GSE*2
2.8 3.2 40 40 1 / 220 ~ 240 / 50 8.0 / 7.0 / 5.0 8.0 / 7.0 / 5.0 39 / 35 / 25 915 x 282 x 165 11.2(24.7) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU12GSE*2
3.6 4.0 40 40 1 / 220 ~ 240 / 50 10.0 / 8.0 / 6.0 10.0 / 8.0 / 6.0 41 / 36 / 27 915 x 282 x 165 11.2(24.7) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU15GSE*2
4.5 5.0 40 40 1 / 220 ~ 240 / 50 10.5 / 8.0 / 6.0 10.5 / 8.0 / 6.0 42 / 36 / 27 915 x 282 x 165 11.2(24.7) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU18GS8*2
5.6 6.3 35 35 1 / 220 ~ 240 / 50 14.4 / 13.0 / 11.0 14.4 / 13.0 / 11.0 37 / 34 / 31 1,107 x 299 x 200 15(33.1) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU24GS8*2
7.1 8.0 35 35 1 / 220 ~ 240 / 50 17.9 / 14.4 / 12.0 17.9 / 14.4 / 12.0 43 / 37 / 32 1,107 x 299 x 200 15(33.1) 9.52(3/8) 15.88(5/8) 16(5/8)

Liquid Piping Connection Gas Drain

I.D.

Liquid Piping Connection Gas Drain

I.D.

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU07GSF*2 ARNU09GSF*2 PQDSA PQDSB / PQDSB1 PQDSBC ARNU12GSF*2

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2 PQDSA PQDSB / PQDSB1 PQDSBC ARNU15GSE*2 ARNU18GS8*2 ARNU24GS8*2

Wired Remote Controller


Standard Type Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller


Standard Type

Wired Remote Controller


Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCVCL0QW (white)

PQRCHCA0Q(Black) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCVCL0QW (white)

PQRCHCA0Q(Black) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

98

99

Standard ARNU07GSBL2 / ARNU09GSBL2 ARNU12GSBL2 / ARNU15GSBL2 ARNU18GSCL2 / ARNU24GSCL2

Wall Mounted ARNU07GSEL2 / ARNU09GSEL2 ARNU12GSEL2 / ARNU15GSEL2 ARNU18GS5L2 / ARNU24GS5L2

Indoor Unit_MULTI V

Model
Capacity Power Input Power Supply Airflow Rate Sound Pressure Dimensions Net Weight Cooling Heating Body H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU07GSBL2
2.2 2.5 21 21 1 / 220 ~ 240 / 50 7.0 / 6.5 / 5.5 7.0 / 6.5 / 5.5 32 / 30 / 25 895 x 289 x 215 10.0(22.0) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU09GSBL2
2.8 3.2 21 21 1 / 220 ~ 240 / 50 8.0 / 7.0 / 5.5 8.0 / 7.0 / 5.5 35 / 32 / 27 895 x 289 x 215 10.0(22.0) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU12GSBL2
3.6 4.0 21 21 1 / 220 ~ 240 / 50 9.5 / 8.2 / 6.5 9.5 / 8.2 / 6.5 37 / 36 / 33 895 x 289 x 215 10.0(22.0) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU15GSBL2
4.5 5.0 21 21 1 / 220 ~ 240 / 50 10.5 / 9.0 / 7.0 10.5 / 9.0 / 7.0 41 / 38 / 33 895 x 289 x 215 10.0(22.0) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU18GSCL2
5.6 6.3 39.5 39.5 1 / 220 ~ 240 / 50 12.5 / 12.0 / 11.3 12.5 / 12.0 / 11.3 44 / 40 / 36 1,030 x 325 x 255 14.0(30.9) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU24GSCL2
7.1 8.0 39.5 39.5 1 / 220 ~ 240 / 50 14.0 / 12.7 / 11.5 14.0 / 12.7 / 11.5 45 / 42 / 38 1,030 x 325 x 255 14.0(30.9) 9.52(3/8) 15.88(5/8) 16(5/8)

Model
Capacity Power Input Power Supply Airflow Rate Sound Pressure Dimensions Net Weight Cooling Heating Body H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU07GSEL2
2.2 2.5 40 40 1 / 220 ~ 240 / 50 5.6 / 5.0 / 4.6 5.6 / 5.0 / 4.6 37 / 33 / 23 895 x 282 x 165 9(19.8) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU09GSEL2
2.8 3.2 40 40 1 / 220 ~ 240 / 50 7.0 / 6.5 / 6.0 7.0 / 6.5 / 6.0 39 / 35 / 25 895 x 282 x 165 9(19.8) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU12GSEL2
3.6 4.0 40 40 1 / 220 ~ 240 / 50 9.5 / 9.0 / 8.5 9.5 / 9.0 / 8.5 41 / 36 / 27 895 x 282 x 165 9(19.8) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU15GSEL2
4.5 5.0 40 40 1 / 220 ~ 240 / 50 10.5 / 9.0 / 8.5 10.5 / 9.0 / 8.5 42 / 36 / 27 895 x 282 x 165 9(19.8) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU18GS5L2
5.6 6.3 40 40 1 / 220 ~ 240 / 50 12.0 / 10.5 / 9.0 12.0 / 10.5 / 9.0 44 / 40 / 36 1,090 x 300 x 178 12(26.5) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU24GS5L2
7.1 8.0 40 40 1 / 220 ~ 240 / 50 14.0 / 13.0 / 10.0 14.0 / 13.0 / 10.0 46 / 41 / 38 1,090 x 300 x 178 12(26.5) 9.52(3/8) 15.88(5/8) 16(5/8)

Liquid Piping Connection Gas Drain

I.D.

Liquid Piping Connection Gas Drain

I.D.

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU07GSBL2 ARNU09GSBL2 ARNU12GSBL2 ARNU15GSBL2 ARNU18GSCL2 ARNU24GSCL2

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU07GSEL2 ARNU09GSEL2 ARNU12GSEL2 PQDSA PQDSB / PQDSB1 PQDSBC ARNU15GSEL2 ARNU18GS5L2 ARNU24GS5L2 PQDSA PQDSB / PQDSB1 PQDSBC

Wired Remote Controller


Standard Type Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller


Standard Type

Wired Remote Controller


Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCVCL0QW (white)

PQRCHCA0Q(Black) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCVCL0QW (white)

PQRCHCA0Q(Black) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

100

101

Console ARNU07GQAA2 / ARNU09GQAA2 ARNU12GQAA2 / ARNU15GQAA2

Indoor Unit_MULTI V

Model
Capacity Power Input Power Supply Airflow Rate Sound Pressure Dimensions Net Weight Cooling Heating Body H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU07GQAA2
2.2 2.5 30 30 1 / 220 ~ 240 / 50 6.7 / 5.9 / 4.8 6.7 / 5.9 / 4.8 37 / 34 / 28 700 x 600 x 210 14.0(30.9) 6.35(1/4) 12.7(1/2) 12.2(15/32)

ARNU09GQAA2
2.8 3.2 30 30 1 / 220 ~ 240 / 50 6.7 / 5.9 / 4.8 6.7 / 5.9 / 4.8 37 / 34 / 28 700 x 600 x 210 14.0(30.9) 6.35(1/4) 12.7(1/2) 12.2(15/32)

ARNU12GQAA2
3.6 4.0 30 30 1 / 220 ~ 240 / 50 7.5 / 5.9 / 4.8 7.5 / 5.9 / 4.8 39 / 34 / 28 700 x 600 x 210 14.0(30.9) 6.35(1/4) 12.7(1/2) 12.2(15/32)

ARNU15GQAA2
4.5 5.0 30 30 1 / 220 ~ 240 / 50 8.7 / 6.7 / 5.9 8.7 / 6.7 / 5.9 42 / 37 / 31 700 x 600 x 210 14.0(30.9) 6.35(1/4) 12.7(1/2) 12.2(15/32)

Liquid Piping Connection Gas Drain

I.D.

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU07GQAA2 ARNU09GQAA2 PQDSA PQDSB / PQDSB1 PQDSBC ARNU12GQAA2 ARNU15GQAA2

Wired Remote Controller


Deluxe Type Standard Type Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

102

103

4 Way Cassette (570x570) ARNU05GTRC2 / ARNU07GTRC2 ARNU09GTRC2 / ARNU12GTRC2 ARNU15GTQC2 / ARNU18GTQC2

4 Way Cassette (840x840) ARNU24GTPC2 / ARNU28GTPC2 ARNU36GTNC2 / ARNU42GTMC2 ARNU48GTMC2

Indoor Unit_MULTI V

Model
Capacity Power Input Power Supply Airflow Rate Cooling Heating H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU05GTRC2
1.6 1.8 30 30 1 / 220 ~ 240 / 50 7.5 / 7.0 / 6.6 7.5 / 7.0 / 6.6 29 / 27 / 26 570 x 214 x 570 13.1(28.9) PTPKQ0 6.35(1/4) 12.7(1/2) 25(31/32) PT-UQC Morning fog

ARNU07GTRC2
2.2 2.5 30 30 1 / 220 ~ 240 / 50 7.5 / 7.0 / 6.6 7.5 / 7.0 / 6.6 29 / 27 / 26 570 x 214 x 570 13.1(28.9) PTPKQ0 6.35(1/4) 12.7(1/2) 25(31/32) PT-UQC Morning fog 700 x 22 x 700 3

ARNU09GTRC2
2.8 3.2 30 30 1 / 220 ~ 240 / 50 8.0 / 7.5 / 7.1 8.0 / 7.5 / 7.1 30 / 29 / 27 570 x 214 x 570 14.2(31.3) PTPKQ0 6.35(1/4) 12.7(1/2) 25(31/32) PT-UQC Morning fog 700 x 22 x 700 3

ARNU12GTRC2
3.6 4.0 30 30 1 / 220 ~ 240 / 50 8.7 / 8.0 / 7.0 8.7 / 8.0 / 7.0 32 / 30 / 27 570 x 214 x 570 14.2(31.3) PTPKQ0 6.35(1/4) 12.7(1/2) 25(31/32) PT-UQC Morning fog 700 x 22 x 700 3

ARNU15GTQC2
4.5 5.0 30 30 1 / 220 ~ 240 / 50 11.0 / 10.0 / 9.3 11.0 / 10.0 / 9.3 36 / 34 / 32 570 x 256 x 570 15.5(34.2) PTPKQ0 6.35(1/4) 12.7(1/2) 25(31/32) PT-UQC Morning fog 700 x 22 x 700 3

ARNU18GTQC2
5.6 6.3 30 30 1 / 220 ~ 240 / 50 11.2 / 11.0 / 10.0 11.2 / 11.0 / 10.0 37 / 35 / 34 570 x 256 x 570 15.5(34.2) PTPKQ0 6.35(1/4) 12.7(1/2) 25(31/32) PT-UQC Morning fog 700 x 22 x 700 3

Model
Capacity Power Input Power Supply Airflow Rate Cooling Heating H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU24GTPC2
7.1 8.0 33 33 1 / 220 ~ 240 / 50 17 / 15 / 13 17 / 15 / 13 36 / 34 / 31 840 x 204 x 840 20.8(45.8) PTPKM0 9.52(3/8) 15.88(5/8) 25(31/32) PT-UMC1 Morning fog

ARNU28GTPC2
8.2 9.2 33 33 1 / 220 ~ 240 / 50 19 / 16 / 14 19 / 16 / 14 39 / 35 / 33 840 x 204 x 840 20.8(45.8) PTPKM0 9.52(3/8) 15.88(5/8) 25(31/32) PT-UMC1 Morning fog 950 x 25 x 950 5.6

ARNU36GTNC2
10.6 11.9 144 144 1 / 220 ~ 240 / 50 25 / 21 / 19 25 / 21 / 19 43 / 40 / 37 840 x 246 x 840 23.5(51.8) PTPKM0 9.52(3/8) 15.88(5/8) 25(31/32) PT-UMC1 Morning fog 950 x 25 x 950 5.6

ARNU42GTMC2
12.3 13.8 144 144 1 / 220 ~ 240 / 50 30 / 27 / 24 30 / 27 / 24 44 / 41 / 38 840 x 288 x 840 25.6(56.4) PTPKM0 9.52(3/8) 15.88(5/8) 25(31/32) PT-UMC1 Morning fog 950 x 25 x 950 5.6

ARNU48GTMC2
14.1 15.9 144 144 1 / 220 ~ 240 / 50 31 / 29 / 27 31 / 29 / 27 46 / 43 / 41 840 x 288 x 840 25.6(56.4) PTPKM0 9.52(3/8) 15.88(5/8) 25(31/32) PT-UMC1 Morning fog 950 x 25 x 950 5.6

Sound Pressure Dimensions Body Net Weight Neoplasma Purifying Filter Liquid Piping Connection Gas Drain Model Colour Decoration Panel Dimensions Weight

I.D.

WxHxD

mm kg

700 x 22 x 700 3

Sound Pressure Dimensions Body Net Weight Neoplasma Purifying Filter Liquid Piping Connection Gas Drain Model Colour Decoration Panel Dimensions Weight

I.D.

WxHxD

mm kg

950 x 25 x 950 5.6

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Accessories
Model
Without Case (1 Contact Point) Dry Contact Front Panel With Case (1 Contact Point) With Case (2 Contact Point)
ARNU05GTRC2 ARNU07GTRC2 ARNU09GTRC2 ARNU12GTRC2 ARNU15GTQC2 ARNU18GTQC2

Accessories
Model
Without Case (1 Contact Point) Dry Contact Front Panel Auto Elevation Grille Ventilation Kit With Case (1 Contact Point) With Case (2 Contact Point)
ARNU24GTPC2 ARNU28GTPC2 ARNU36GTNC2 PQDSA PQDSB / PQDSB1 PQDSBC PT-UMC PTEGMO PTVK410 / PTVK420 / PTVK 430 ARNU42GTMC2 ARNU48GTMC2 PQDSA PQDSB / PQDSB1 PQDSBC PT-UQC

Wired Remote Controller


Deluxe Type Standard Type Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller


Deluxe Type Standard Type

Wired Remote Controller


Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

104

105

2 Way Cassette ARNU18GTLC2 / ARNU24GTLC2

1 Way Cassette ARNU07GTUC2 / ARNU09GTUC2 ARNU12GTUC2 / ARNU18GTTC2 ARNU24GTTC2


Grill Type

Indoor Unit_MULTI V

Model
Capacity Power Input Power Supply Airflow Rate Sound Pressure Dimensions Net Weight Cooling Heating Body H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU18GTLC2
5.6 6.3 70 70 1 / 220 ~ 240 / 50 13 / 12 / 10 13 / 12 / 10 40 / 36 / 32 830 x 225 x 550 22(48.5) 6.35(1/4) 12.7(1/2) 25(31/32) PT-HLC Morning fog

ARNU24GTLC2
7.1 8.0 70 70 1 / 220 ~ 240 / 50 17 / 15 / 13 17 / 15 / 13 42 / 38 / 34 830 x 225 x 550 22(48.5) 9.52(3/8) 15.88(5/8) 25(31/32) PT-HLC Morning fog 1,050 x 28 x 640 4

Model
Capacity Power Input Power Supply Airflow Rate Sound Pressure Dimensions Net Weight Cooling Heating Body H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU07GTUC2
2.2 2.5 40 40 1 / 220 ~ 240 / 50 8.2 / 7.3 / 6.4 8.2 / 7.3 / 6.4 32 / 29 / 25 860 x 132 x 450 14.7(32.4) 6.35(1/4) 12.7(1/2) 25(31/32) White

ARNU09GTUC2
2.8 3.2 40 40 1 / 220 ~ 240 / 50 9.2 / 8.6 / 8.2 9.2 / 8.6 / 8.2 35 / 34 / 32 860 x 132 x 450 14.7(32.4) 6.35(1/4) 12.7(1/2) 25(31/32) White 1,100 x 34 x 500 4.6

ARNU12GTUC2
3.6 4.0 40 40 1 / 220 ~ 240 / 50 10 / 9.2 / 8.2 10 / 9.2 / 8.2 38 / 35 / 32 860 x 132 x 450 14.7(32.4) 6.35(1/4) 12.7(1/2) 25(31/32) White 1,100 x 34 x 500 4.6

ARNU18GTTC2
5.6 6.3 70 70 1 / 220 ~ 240 / 50 13.3 / 12.1 / 10.9 13.3 / 12.1 / 10.9 40 / 37 / 35 1,180 x 132 x 450 18.7(41.23) 6.35(1/4) 12.7(1/2) 25(31/32) White 1,100 x 34 x 500 5.5

ARNU24GTTC2
7.1 7.1 70 70 1 / 220 ~ 240 / 50 14.6 / 13.3 / 11.5 14.6 / 13.3 / 11.5 43 / 40 / 36 1,180 x 132 x 450 18.7(41.23) 9.52(3/8) 15.88(5/8) 25(31/32) White 1,100 x 34 x 500 5.5

Liquid Piping Connection Gas Drain Model Colour Decoration Panel Dimensions Weight

I.D.

WxHxD

mm kg

1,050 x 28 x 640 4

Liquid Piping Connection Gas Drain Model Colour Decoration Panel Dimensions Weight

I.D.

PT-UUC(Grill), PT-UUD(Panel) PT-UUC(Grill), PT-UUD(Panel) PT-UUC(Grill), PT-UUD(Panel) PT-UTC(Grill), PT-UTD(Panel) PT-UTC(Grill), PT-UTD(Panel)

WxHxD

mm kg

1,100 x 34 x 500 4.6

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU18GTLC2 PQDSA PQDSB / PQDSB1 PQDSBC ARNU24GTLC2

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU07GTUC2 ARNU09GTUC2 ARNU12GTUC2 PQDSA PQDSB / PQDSB1 PQDSBC ARNU18GTTC2 ARNU24GTTC2

Wired Remote Controller


Deluxe Type Standard Type Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller


Deluxe Type Standard Type

Wired Remote Controller


Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

106

107

Low Static Duct ARNU05GL1G2 / ARNU07GL1G2 ARNU09GL1G2

Low Static Duct ARNU12GL2G2 / ARNU15GL2G2 ARNU18GL2G2 / ARNU21GL3G2 ARNU24GL3G2

Indoor Unit_MULTI V

: Grey cells are preliminary data.

: Grey cells are preliminary data.

Model
Capacity Power Input Power Supply Cooling H/M/L Heating H/M/L External Static Pressure High Model-Factory Set Sound Pressure H/M/L Dimensions Body WxHxD Net Weight Liquid Piping Connection Gas Drain I.D. Airflow Rate
(High mode)

ARNU05GL1G2 Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min mmAq(Pa) dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)
1.7 1.9 40 40 1 / 220 ~ 240 / 50 7.0 / 6.0 / 5.5 7.0 / 6.0 / 5.5 2.54(25) 26 / 25 / 23 700 x 190 x 700 17.5(38.6) 6.35(1/4) 12.7(1/2) 25(31/32)

ARNU07GL1G2
2.2 2.5 40 40 1 / 220 ~ 240 / 50 7.5 / 6.5 / 5.5 7.5 / 6.5 / 5.5 2.54(25) 27 / 26 / 23 700 x 190 x 700 17.5(38.6) 6.35(1/4) 12.7(1/2) 25(31/32)

ARNU09GL1G2
2.8 3.2 40 40 1 / 220 ~ 240 / 50 9.0 / 7.0 / 5.5 9.0 / 7.0 / 5.5 2.54(25) 30 / 26 / 23 700 x 190 x 700 17.5(38.6) 6.35(1/4) 12.7(1/2) 25(31/32)

Model
Capacity Power Input Power Supply Cooling H/M/L Heating H/M/L External Static Pressure High Model-Factory Set Sound Pressure H/M/L Dimensions Body WxHxD Net Weight Liquid Piping Connection Gas Drain I.D. Airflow Rate
(High mode)

ARNU12GL2G2 Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min mmAq(Pa) dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)
3.6 4.0 85 85 1 / 220 ~ 240 / 50 10.0 / 8.5 / 7.0 10.0 / 8.5 / 7.0 2.54(25) 31 / 29 / 26 900 x 190 x 700 23(50.7) 6.35(1/4) 12.7(1/2) 25(31/32)

ARNU15GL2G2
4.5 5.0 85 85 1 / 220 ~ 240 / 50 12.5 / 10.0 / 8.5 12.5 / 10.0 / 8.5 2.54(25) 34 / 31 / 29 900 x 190 x 700 23(50.7) 6.35(1/4) 12.7(1/2) 25(31/32)

ARNU18GL2G2
5.6 6.3 85 85 1 / 220 ~ 240 / 50 15.0 / 12.5 / 10.0 15.0 / 12.5 / 10.0 2.54(25) 36 / 34 / 31 900 x 190 x 700 23(50.7) 6.35(1/4) 12.7(1/2) 25(31/32)

ARNU21GL3G2
6.2 7.0 115 115 1 / 220 ~ 240 / 50 17.5 / 14.0 / 12.0 17.5 / 14.0 / 12.0 2.54(25) 37 / 34 / 32 1,100 x 190 x 700 27(59.5) 9.52(3/8) 15.88(5/8) 25(31/32)

ARNU24GL3G2
7.1 8.0 115 115 1 / 220 ~ 240 / 50 20.0 / 16.0 / 12.0 20.0 / 16.0 / 12.0 2.54(25) 39 / 35 / 32 1,100 x 190 x 700 27(59.5) 9.52(3/8) 15.88(5/8) 25(31/32)

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU05GL1G2 ARNU07GL1G2 PQDSA PQDSB / PQDSB1 PQDSBC ARNU09GL1G2

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU12GL2G2 ARNU15GL2G2 ARNU18GL2G2 PQDSA PQDSB / PQDSB1 PQDSBC ARNU21GL3G2 ARNU24GL3G2

Wired Remote Controller


Deluxe Type Standard Type Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller


Deluxe Type Standard Type

Wired Remote Controller


Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

108

109

Built-in Duct ARNU07GB3G2 / ARNU09GB3G2 ARNU12GB3G2 / ARNU15GB3G2

Built-in Duct ARNU18GB4G2 / ARNU24GB4G2

Indoor Unit_MULTI V

Model
Capacity Power Input Power Supply Cooling H/M/L Heating H/M/L External Static Pressure High Model-Factory Set Sound Pressure H/M/L Body WxHxD Dimensions Suction Grille WxHxD Suction Canvas WxHxD Net Weight Liquid Piping Connection Gas Drain I.D. Airflow Rate
(High mode)

ARNU07GB3G2 Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min mmAq(Pa) dBA mm mm mm kg(lbs) mm(inch) mm(inch) mm(inch)
2.2 2.5 30 30 1 / 220 ~ 240 / 50 8.0 / 6.5 / 5.5 8.0 / 6.5 / 5.5 2(20) 33 / 32 / 29 820 x 190 x 575 910 x 56 x 359 821 x 42~250 x 274 21(46.3) 6.35(1/4) 12.7(1/2) 25.4(1)

ARNU09GB3G2
2.8 3.2 30 30 1 / 220 ~ 240 / 50 9.0 / 7.0 / 6.0 9.0 / 7.0 / 6.0 2(20) 34 / 33 / 32 820 x 190 x 575 910 x 56 x 359 821 x 42~250 x 274 21(46.3) 6.35(1/4) 12.7(1/2) 25.4(1)

ARNU012GB3G2
3.6 4.0 30 30 1 / 220 ~ 240 / 50 10.0 / 8.0 / 6.5 10.0 / 8.0 / 6.5 2(20) 35 / 34 / 33 820 x 190 x 575 910 x 56 x 359 821 x 42~250 x 274 21(46.3) 6.35(1/4) 12.7(1/2) 25.4(1)

ARNU15GB3G2
4.5 5.0 30 30 1 / 220 ~ 240 / 50 11.0 / 10.0 / 8.0 11.0 / 10.0 / 8.0 2(20) 41 / 40 / 37 820 x 190 x 575 910 x 56 x 359 821 x 42~250 x 274 21(46.3) 6.35(1/4) 12.7(1/2) 25.4(1)

Model
Capacity Power Input Power Supply Cooling H/M/L Heating H/M/L External Static Pressure High Model-Factory Set Sound Pressure H/M/L Body WxHxD Dimensions Suction Grille WxHxD Suction Canvas WxHxD Net Weight Liquid Piping Connection Gas Drain I.D. Airflow Rate
(High mode)

ARNU18GB4G2 Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min mmAq(Pa) dBA mm mm mm kg(lbs) mm(inch) mm(inch) mm(inch)
5.6 6.3 80 80 1 / 220 ~ 240 / 50 14.0 / 12.0 / 10.0 14.0 / 12.0 / 10.0 2(20) 43 / 40 / 37 1,100 x 190 x 575 1,188 x 56 x 359 1,100 x 42~250 x 274 26(57.3) 6.35(1/4) 12.7(1/2) 25.4(1)

ARNU24GB4G2
7.1 8.0 80 80 1 / 220 ~ 240 / 50 17.0 / 15.0 / 10.0 17.0 / 15.0 / 10.0 2(20) 46 / 43 / 37 1,100 x 190 x 575 1,188 x 56 x 359 1,100 x 42~250 x 274 26(57.3) 9.52(3/8) 15.88(5/8) 25.4(1)

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU07GB3G2 ARNU09GB3G2 PQDSA PQDSB / PQDSB1 PQDSBC ARNU012GB3G2 ARNU15GB3G2

Accessories
Model
Without Case (1 Contact Point) Dry Contact Suction Grille Suction Canvas With Case (1 Contact Point) With Case (2 Contact Point)
ARNU18GB4G2 PQDSA PQDSB / PQDSB1 PQDSBC PBSGB30 PBSC30 ARNU24GB4G2

Wired Remote Controller


Deluxe Type Standard Type Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller


Deluxe Type Standard Type

Wired Remote Controller


Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

110

111

High Static Duct

High Static Duct

ARNU07GBHA2 / ARNU09GBHA2 ARNU12GBHA2 / ARNU15GBHA2 ARNU18GBHA2 / ARNU24GBHA2

ARNU28GBGA2 / ARNU36GBGA2 ARNU42GBGA2 / ARNU48GBRA2 ARNU54GBRA2 / ARNU76GB8A2 ARNU96GB8A2


Indoor Unit_MULTI V

Model
Capacity Power Input Power Supply Cooling H/M/L Heating H/M/L External Static Pressure High Model-Factory Set Sound Pressure H/M/L Dimensions Body WxHxD Net Weight Liquid Piping Connection Gas Drain I.D. Airflow Rate
(High mode)

ARNU07GBHA2 Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min mmAq(Pa) dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)
2.2 2.5 150 150 1 / 220 ~ 240 / 50 8.5 / 7.5 / 6.0 8.5 / 7.5 / 6.0 8(78) 34 / 33 / 32 882 x 260 x 450 26(57.4) 6.35(1/4) 12.7(1/2) 25(31/32)

ARNU09GBHA2
2.8 3.2 150 150 1 / 220 ~ 240 / 50 10.0 / 8.5 / 7.5 10.0 / 8.5 / 7.5 8(78) 35 / 34 / 33 882 x 260 x 450 26(57.4) 6.35(1/4) 12.7(1/2) 25(31/32)

ARNU12GBHA2
3.6 4.0 150 150 1 / 220 ~ 240 / 50 12.0 / 10.0 / 8.5 12.0 / 10.0 / 8.5 8(78) 37 / 35 / 34 882 x 260 x 450 26(57.4) 6.35(1/4) 12.7(1/2) 25(31/32)

ARNU15GBHA2
4.5 5.0 150 150 1 / 220 ~ 240 / 50 13.5 / 12.0 / 8.5 13.5 / 12.0 / 8.5 8(78) 39 / 37 / 34 882 x 260 x 450 26(57.4) 6.35(1/4) 12.7(1/2) 25(31/32)

ARNU18GBHA2
5.6 6.3 150 150 1 / 220 ~ 240 / 50 15.5 / 13.5 / 12.4 15.5 / 13.5 / 12.4 8(78) 40 / 38 / 37 882 x 260 x 450 26.5(58.4) 6.35(1/4) 12.7(1/2) 25(31/32)

ARNU24GBHA2
7.1 8.0 150 150 1 / 220 ~ 240 / 50 18.3 / 16.9 / 15.5 18.3 / 16.9 / 15.5 8(78) 42 / 41 / 40 882 x 260 x 450 26.5(58.4) 9.52(3/8) 15.88(5/8) 25(31/32)

Model
Capacity Power Input Power Supply Cooling H/M/L Heating H/M/L External Static Pressure High Model-Factory Set Sound Pressure H/M/L Dimensions Body WxHxD Net Weight Liquid Piping Connection Gas Drain I.D. Airflow Rate
(High mode)

ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2 ARNU48GBRA2 ARNU54GBRA2 ARNU76GB8A2 ARNU96GB8A2 Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min mmAq(Pa) dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)
8.2 9.2 450 450 1 / 220 ~ 240 / 50 25.9 / 24.1 / 21.8 25.9 / 24.1 / 21.8 10(98) 42 / 41 / 40 1,182 x 298 x 450 38.0(83.8) 9.52(3/8) 15.88(5/8) 25(31/32) 10.6 11.9 450 450 1 / 220 ~ 240 / 50 32.3 / 29.0 / 25.3 32.3 / 29.0 / 25.3 10(98) 44 / 43 / 42 1,182 x 298 x 450 38.0(83.8) 9.52(3/8) 15.88(5/8) 25(31/32) 12.3 13.8 450 450 1 / 220 ~ 240 / 50 34.5 / 32.3 / 30.7 34.5 / 32.3 / 30.7 10(98) 45 / 44 / 44 1,182 x 298 x 450 38.0(83.8) 9.52(3/8) 15.88(5/8) 25(31/32) 14.1 15.9 450 450 1 / 220 ~ 240 / 50 44.8 / 40.6 / 33.3 44.8 / 40.6 / 33.3 14(137) 45 / 43 / 41 1,230 x 380 x 590 53(117) 9.52(3/8) 15.88(5/8) 25(31/32) 15.8 18.0 450 450 1 / 220 ~ 240 / 50 51.0 / 44.8 / 40.6 51.0 / 44.8 / 40.6 14(137) 46 / 45 / 43 1,230 x 380 x 590 53(117) 9.52(3/8) 15.88(5/8) 25(31/32) 22.4 25.2 800 800 1 / 220 ~ 240 / 50 60.0 / 50.0 / 50.0 60.0 / 50.0 / 50.0 22(216) 50 / 48 / 48 1,562 x 460 x 688 87(192) 9.52(3/8) 15.88(5/8) 25(31/32) 28.0 31.5 800 800 1 / 220 ~ 240 / 50 72.0 / 64.0 / 64.0 72.0 / 64.0 / 64.0 22(216) 52 / 50 / 50 1,562 x 460 x 688 87(192) 9.52(3/8) 15.88(5/8) 25(31/32)

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2 ARNU18GBHA2 ARNU24GBHA2

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2 ARNU48GBRA2 ARNU54GBRA2 ARNU76GB8A2 ARNU96GB8A2 PQDSA PQDSB / PQDSB1 PQDSBC PQDSA PQDSB / PQDSB1 PQDSBC

Wired Remote Controller


Deluxe Type Standard Type Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller


Deluxe Type Standard Type

Wired Remote Controller


Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

112

113

Fresh Air Intake Unit


Fresh Outdoor Air Supply
The LG Fresh Air Intake Unit (FAU) is the alternative solution for ventilation, which supplies the fresh outdoor air indoors as well as being able to cool and heat air inside simultaneously. It means the indoor space can have positive air pressure consistently, which can block cold, hot or contaminated air from outside.
Fresh Air Intake Unit

Fresh Air Intake Unit ARNU48GBRZ2 / ARNU76GB8Z2 ARNU96GB8Z2

ARNU48GBRZ2

Indoor Unit_MULTI V

ARNU76GB8Z2
100% Outdoor Air
Indoor Unit Diffuser Indoor Unit Diffuser Indoor Unit Diffuser

ARNU96GB8Z2

Model
Air Conditioning Air Conditioning + Outdoor Air Supply

ARNU48GBRZ2 Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min mmAq(Pa) dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)
14.1 13.5 169 169 1 / 220 ~ 240 / 50 18.8 / 14.7 / 14.7 18.8 / 14.7 / 14.7 18(0.7) 44 / 42 / 42 1,230 x 380 x 590 45(99) 9.52(3/8) 15.88(5/8) 25(31/32)

ARNU76GB8Z2
22.4 21.4 230 230 1 / 220 ~ 240 / 50 23.7 / 13.2 / 13.2 23.7 / 13.2 / 13.2 22(0.86) 49 / 47 / 47 1,562 x 460 x 688 73(161) 9.52(3/8) 19.05(3/4) 25(31/32)

ARNU96GB8Z2
28.0 26.7 360 360 1 / 220 ~ 240 / 50 35.7 / 23.7 / 23.7 35.7 / 23.7 / 23.7 22(0.86) 50 / 48 / 48 1,562 x 460 x 688 73(161) 9.52(3/8) 22.2(7/8) 25(31/32)

Capacity Power Input Power Supply

MULTI V lll Outdoor Units

Economic Operation
Using the free cooling and heating can save costs by blowing the natural outdoor air inside when the season changes. Spring Season
Fresh Air Intake Unit

Cooling H/M/L Heating H/M/L External Static Pressure High Model-Factory Set Sound Pressure H/M/L Dimensions Body WxHxD Net Weight Liquid Piping Connection Gas Drain I.D. Airflow Rate
(High mode)

Autumn Season
Fresh Air Intake Unit

Indoor Unit

Diffuser

Indoor Unit

Diffuser

OFF
Warm Air + Outdoor Air Supply

OFF
Cool Air + Outdoor Air Supply

Notes: 1. Capacities are based on the following conditions: Cooling: Outdoor temp. 33C(91.4F)DB / 28C(82.4F)WB IDU~ODU Piping Length : 7.5m Level Difference of Zero Heating: Outdoor temp. 0C(32F)DB / -2.9C(26.78F)WB Interconnecting Piping Length : 7.5m Level Difference of Zero 2. Capacities are net capacities 3. Noise Level is under standard mode(For actual High Mode(Factory set) condition, Noise Level may exceed the standard level by 1.5dB(A)) 4. Due to our policy of innovation some specifications may be changed without prior notification

Min. 2m 2 1 1/30 Slope

Outlet Air 4 5 Exhaust air 1 : Inlet Hood 2 : Intake Air Duct 3 : Fresh Air Intake Unit 4 : Exhaus Fan 5 : Door

Installation Scene

Caution
MULTI V lll Outdoor Units MULTI V lll Outdoor Units
1. Operation range (Cooling : 5C ~ 43C, Heating : -5C ~ 43C) 2. Installation of exhaust fan is recommended for a sealed room. 3. Indoor Unit Connection

BLDC Fan Motor


It can reduce a noise at low frequencies.

No 1 2

Connection Condition Fresh Air Intake Units only are connected with outdoor units Mixture connection with general indoor unit and Fresh Intake units

Combination 1) The total capcity of Fresh Air Intak Unit should be 50~100% of outdoor unit. 2) The max quantity of Fresh Air Intake is 2 units. 1) The total capacity of indoor units(standard indoor unit + Fresh Air Intake Unit) should be 50~100% of outdoor unit. 2) The total capacity of Fresh Air Intake Unit should be less than 30% of the total capacity of indoor units.

Wired Remote Controller


Standard Type Standard Type

PQRCVSL0

PQRCVSL0QW

114

115

Ceiling & Floor ARNU09GVEA2 / ARNU12GVEA2

Ceiling Suspended URNU18GVJA2 / URNU24GVJA2 URNU36GVKA2 / URNU48GVLA2


URNU48GVLA2

URNU18GVJA2 / URNU24GVJA2

URNU36GVKA2

Indoor Unit_MULTI V

Model
Capacity Power Input Power Supply Airflow Rate Sound Pressure Dimensions Net Weight Cooling Heating Body H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU09GVEA2
2.8 3.2 30 30 1 / 220 ~ 240 / 50 7.6 / 6.9 / 6.2 7.6 / 6.9 / 6.2 36 / 32 / 28 900 x 490 x 200 13.7(30.2) 6.35(1/4) 12.7(1/2) 16(5/8)

ARNU12GVEA2
3.6 4.0 30 30 1 / 220 ~ 240 / 50 9.2 / 7.6 / 6.9 9.2 / 7.6 / 6.9 38 / 36 / 30 900 x 490 x 200 13.7(30.2) 6.35(1/4) 12.7(1/2) 16(5/8)

Model
Capacity Power Input Power Supply Airflow Rate Sound Pressure Dimensions Net Weight Cooling Heating Body H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

URNU18GVJA2
5.6 6.3 63 63 1 / 220 ~ 240 / 50 16.0 / 14.0 /12.0 16.0 / 14.0 /12.0 42 / 40 / 37 950 x 650 x 220 24.6(54.2) 6.35(1/4) 12.7(1/2) 16(5/8)

URNU24GVJA2
7.1 8.0 63 63 1 / 220 ~ 240 / 50 18.0 / 16.0 / 14.0 18.0 / 16.0 / 14.0 43 / 41 / 39 950 x 650 x 220 24.6(54.2) 9.52(3/8) 15.88(5/8) 16(5/8)

URNU36GVKA2
10.6 11.9 140 140 1 / 220 ~ 240 / 50 24.6 / 23.0 / 21.4 24.6 / 23.0 / 21.4 48 / 46 / 44 1,350 x 650 x 220 35.0(77.2) 9.52(3/8) 15.88(5/8) 16(5/8)

URNU48GVLA2
14.1 15.9 190 190 1 / 220 ~ 240 / 50 35.0 / 32.0 / 30.0 35.0 / 32.0 / 30.0 49 / 48 / 47 1,750 x 650 x 220 45.0(99.2) 9.52(3/8) 15.88(5/8) 16(5/8)

Liquid Piping Connection Gas Drain

I.D.

Liquid Piping Connection Gas Drain

I.D.

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU09GVEA2 PQDSA PQDSB / PQDSB1 PQDSBC ARNU12GVEA2

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
URNU18GVJA2 URNU24GVJA2 PQDSA PQDSB / PQDSB1 PQDSBC URNU36GVKA2 URNU48GVLA2

Wired Remote Controller


Deluxe Type Standard Type Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller


Deluxe Type Standard Type

Wired Remote Controller


Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

116

117

Floor Standing with Case ARNU07GCEA2 / ARNU09GCEA2 ARNU12GCEA2 / ARNU15GCEA2 ARNU18GCFA2 / ARNU24GCFA2

Floor Standing without Case ARNU07GCEU2 / ARNU09GCEU2 ARNU12GCEU2 / ARNU15GCEU2 ARNU18GCFU2 / ARNU24GCFU2

Indoor Unit_MULTI V

Model
Capacity Power Input Power Supply Airflow Rate Sound Pressure Dimensions Net Weight Cooling Heating Body H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU07GCEA2
2.2 2.5 30 30 1 / 220 ~ 240 / 50 8.5 / 7.5 / 6.5 8.5 / 7.5 / 6.5 35 / 33 / 31 1,067 x 635 x 203 27(59.5) 6.35(1/4) 12.7(1/2) 12(15/32)

ARNU09GCEA2
2.8 3.2 30 30 1 / 220 ~ 240 / 50 9.5 / 8.5 / 7.5 9.5 / 8.5 / 7.5 36 / 34 / 32 1,067 x 635 x 203 27(59.5) 6.35(1/4) 12.7(1/2) 12(15/32)

ARNU12GCEA2
3.6 4.0 30 30 1 / 220 ~ 240 / 50 10.5 / 9.5 / 8.5 10.5 / 9.5 / 8.5 37 / 35 / 33 1,067 x 635 x 203 27(59.5) 6.35(1/4) 12.7(1/2) 12(15/32)

ARNU15GCEA2
4.5 5.0 30 30 1 / 220 ~ 240 / 50 11.5 / 10.0 / 9.5 11.5 / 10.0 / 9.5 38 / 37 / 35 1,067 x 635 x 203 27(59.5) 6.35(1/4) 12.7(1/2) 12(15/32)

ARNU018GCFA2
5.6 6.3 80 80 1 / 220 ~ 240 / 50 16.0 / 14.0 / 12.0 16.0 / 14.0 / 12.0 40 / 37 / 34 1,345 x 635 x 203 34(75.0) 6.35(1/4) 12.7(1/2) 12(15/32)

ARNU024GCFA2
7.1 8.0 80 80 1 / 220 ~ 240 / 50 18.0 / 16.0 / 14.0 18.0 / 16.0 / 14.0 43 / 40 / 37 1,345 x 635 x 203 34(75.0) 9.52(3/8) 15.88(5/8) 12(15/32)

Model
Capacity Power Input Power Supply Airflow Rate Sound Pressure Dimensions Net Weight Cooling Heating Body H/M/L H/M/L H/M/L WxHxD Cooling Heating Cooling Heating Nom Nom Nom Nom kW kW W W /V/Hz m3/min m3/min dBA mm kg(lbs) mm(inch) mm(inch) mm(inch)

ARNU07GCEU2
2.2 2.5 30 30 1 / 220 ~ 240 / 50 8.5 / 7.5 / 6.5 8.5 / 7.5 / 6.5 35 / 33 / 31 978 x 639 x 190 20(44.1) 6.35(1/4) 12.7(1/2) 12(15/32)

ARNU09GCEU2
2.8 3.2 30 30 1 / 220 ~ 240 / 50 9.5 / 8.5 / 7.5 9.5 / 8.5 / 7.5 36 / 34 / 32 978 x 639 x 190 20(44.1) 6.35(1/4) 12.7(1/2) 12(15/32)

ARNU12GCEU2
3.6 4.0 30 30 1 / 220 ~ 240 / 50 10.5 / 9.5 / 8.5 10.5 / 9.5 / 8.5 37 / 35 / 33 978 x 639 x 190 20(44.1) 6.35(1/4) 12.7(1/2) 12(15/32)

ARNU15GCEU2
4.5 5.0 30 30 1 / 220 ~ 240 / 50 11.5 / 10.0 / 9.5 11.5 / 10.0 / 9.5 38 / 37 / 35 978 x 639 x 190 20(44.1) 6.35(1/4) 12.7(1/2) 12(15/32)

ARNU18GCFU2
5.6 6.3 80 80 1 / 220 ~ 240 / 50 16.0 / 14.0 / 12.0 16.0 / 14.0 / 12.0 40 / 37 / 34 1,256 x 639 x 190 27(59.5) 6.35(1/4) 12.7(1/2) 12(15/32)

ARNU24GCFU2
7.1 8.0 80 80 1 / 220 ~ 240 / 50 18.0 / 16.0 / 14.0 18.0 / 16.0 / 14.0 43 / 40 / 37 1,256 x 639 x 190 27(59.5) 9.52(3/8) 15.88(5/8) 12(15/32)

Liquid Piping Connection Gas Drain

I.D.

Liquid Piping Connection Gas Drain

I.D.

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Note : 1. Capacities are based on the following conditions Cooling - Indoor temp. 27C[80.6F]DB / 19C[66.2F]WB Outdoor temp. 35C[95F]DB / 24C[75.2F]WB Interconnecting piping length 7.5m / Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification Heating - Indoor temp. 20C[68F]DB / 15C[59F]WB Outdoor temp. 7C[44.6F]DB / 6C[42.8F]WB Interconnecting piping length 7.5m / Level difference of zero

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU07GCEA2 ARNU09GCEA2 ARNU12GCEA2 ARNU15GCEA2 ARNU018GCFA2 ARNU024GCFA2

Accessories
Model
Without Case (1 Contact Point) Dry Contact With Case (1 Contact Point) With Case (2 Contact Point)
ARNU07GCEU2 ARNU09GCEU2 ARNU12GCEU2 ARNU15GCEU2 ARNU18GCFU2 ARNU24GCFU2 PQDSA PQDSB / PQDSB1 PQDSBC PQDSA PQDSB / PQDSB1 PQDSBC

Wired Remote Controller


Deluxe Type Standard Type Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller


Deluxe Type Standard Type

Wired Remote Controller


Standard Type Simple Type Simple Type for Hotel

Wireless Remote Controller

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

PQRCUDS0(white) PQRCUDS0B(blue) PQRCUDS0S(silver)

PQRCVSL0

PQRCVSL0QW

PQRCVCL0Q (Black) PQRCHCA0Q(Black) PQRCVCL0QW (white) PQRCHCA0QW(White)

PQWRHDF0

PQWRHQ0FDB

118

119

Total heating & Hot water Solution

HYDRO KIT, using MULTI V to provide floor heating and hot water supply as a total HVAC solution.

126

HYDRO KIT

HYDRO KIT

Easy Installation
Unnecessary to duct for exhaust gas, easy to install as it uses a compact and modular structure.
MULTI V + Boiler MULTI V + HYDRO KIT

High Efficiency through Energy Savings


Possible to install with equivalent levels of capital cost as a boiler system and minimise energy costs by low-priced operating costs.
1st Proposal MULTI V HYDRO KIT (Air Conditioning + Hot water supply + Floor Heating)

() 25,000 20,000 15,000 10,000 5,000 0

Initial Costs

() 2,500 2,000 1,500 1,000 500

Annual Operating Coast

cooling

cooling Hot Water Supply Floor Heating

2nd Proposal MULTI V Air-conditioning + Gas Boiler (Hot water supply + Floor Heating)

100%

90%

95%

229% 171%

Floor Heating

Hot Water Supply

3rd Proposal MULTI V Air-conditioning + Oil Boiler (Hot water supply + Floor Heating)

100%
Gas boiler Oil boiler

Gas boiler Oil boiler

() ()
Oil Tank Boiler

LCC

Initial Costs

() 25,000 20,000 15,000 10,000 5,000

Annual Operating Coast

50,000 40,000 30,000 20,000 10,000

Analysis Conditions
Building Type : Dormitory, flats  Cooling / Floor Heating / Sanitary Hot water for 10 years 229% Cooling : MULTI V Indoor unit Floor Heating : Medium Temp. HYDRO KIT (1ea) 171%  Sanitary Hot water :  High Temp. HYDRO KIT (2ea), Sanitary Hot water tanks Electricity cost : Average cost in EU Gas cost : Average cost in EU Oil cost : Average cost in EU

25,000 20,000 15,000 10,000 5,000

100%

Oil boller Gas boller

90%

95%

100%

Eco-friendly Green Energy Solution


Green energy solution through the reduction of CO2 emmisions.
Conventional system

Gas boller

Oil boller

Gas boller

Oil boller

10 (year)

Energy Saving through Heat Recovery


(%) 120 CO2 emissions
Energy costs can be saved by using the wasted heat from indoors that would normal be sent outdoors when cooling.

100

100% 76%
HR Unit

Refrigerant Cooling

Heat Absorption

HYDRO KIT

60
MULTI V

40

Indoor Cooling

30%
Heat Heat Emission Emission Sanitary Tank

20

Oil boiler

Gas boiler

Hot Water

122

123

High Temperature of HYDRO KIT Concept


Unnecessary to duct exhaust gas, easy to install due to the compact and modular structure

Various Applications
Applicable to a variety of facilities including hospitals, residences and resorts that need water heating and domestic hot water supply

Dual inverter cascade cycle technical


 Max 55% capacity improvement bettter than middle temperature of HYDRO KIT  Max 20% heating operating cost reduction better than middle temperature of HYDRO KIT

High volume of domestic hot water


Compared  to lower temperature, storing high temperature water in a sanitary tank increases a lot the quantity of mixed water available for the user.

Office

University / School

Hospital / Clinic

Cascade R410A to R134a BLDC compressor technology


Leaving water temperature up to 80C Shopping Mall / Restaurant Hotel / Resort Factory Facilities

High Temperature of HYDRO KIT Cycle Diagram


Unnecessary to duct exhaust gas, easy to install as compact and modular structure
Outdoor Unit
Air-Refrigerant

Hotel Application
Constant cooling and heating are possible at the same time during the summer to provide hot water for bathrooms using waste heat energy from indoor cooling by an indoor unit.
Heating by Hot Water

High Temperature HYDRO KIT


Refrigerant Refrigerant Refrigerant Water

AIR

50C

80C

Office Application
In the office while cooling the HR unit allows the sanitary tank to be warmed using waste energy, hot water can be supplied at all times.

High Temperature Technical

Pressure

Water
Two Stage
R410A R134A

Single Stage

AIR
Enthalpy

124

125

Specification

Specification

: Grey cells are preliminary data.

Type Model
Power Supply Capacity (Rated) Power Input Water Inlet/Outlet Temperature Casing Dimensions Net Weight Heat Exchanger Compressor Water Side Piping Connections Refrigerant Side Drain Piping Connectiion Sound Pressure Level Power Supply Cable Communication cable Refrigerant type Control Refrigerant type Refrigerant to Water Precharged Amount Control Cooling Connected to Heat pump Heating Cooling Connected to Heat recovery Heating Only hydrokit Min ~Max Hydrokit + standard IDUs Min ~Max Refrigerant to Refrigerant Cooling Heating Refrigerant to Water Refrigerant to Refrigerant Type Rated Water Flow Head Loss Type Type Inlet Outlet Liquid Side Gas Side Body WxHxD mm inch kg(lbs) L/min kPa Cooling Heating Cooling Heating Cooling Heating / V / Hz kW kW kW kW C C

Med Temp. ARNH10GK2A2


1 / 220 ~ 240 / 50 28 31.5 0.01 0.01 6 50 Painted Steel Plate 520 x 631 x 330 20-15/32 x 24-27/32 x 13 35(77.2) Brazed Plate Hex 46 25 -

Med Temp. ARNH04GK2A2


1 / 220 ~ 240 / 50 12.3 13.8 0.01 0.01 6 50 Painted Steel Plate 520 x 631 x 330 20-15/32 x 24-27/32 x 13 31(68.34) Brazed Plate Hex 23 17 Male PT 1 Male PT 1 9.52(3/8) 15.88(5/8) Male PT 1 26 26 3C x CV2.5 2C x CVV-SB 1.0~1.5 R410A EEV -5C ~ 43C -20C ~ 35C -5C ~ 43C -20C ~ 43C 50 ~ 100 50 ~ 130

Type Model
Power Supply Capacity (Rated) Power Input Water Inlet/Outlet Temperature Casing Dimensions Net Weight Heat Exchanger Compressor Water Side Piping Connections Refrigerant Side Drain Piping Connectiion Sound Pressure Level Power Supply Cable Communication cable Refrigerant type Control Refrigerant type Refrigerant to Water Precharged Amount Control Cooling Connected to Heat pump Heating Cooling Connected to Heat recovery Heating Only hydrokit Min ~Max Hydrokit + standard IDUs Min ~Max Refrigerant to Refrigerant Cooling Heating Refrigerant to Water Refrigerant to Refrigerant Type Rated Water Flow Head Loss Type Type Inlet Outlet Liquid Side Gas Side Body WxHxD mm inch kg(lbs) L/min kPa Cooling Heating Cooling Heating Cooling Heating / V / Hz kW kW kW kW C C

High Temp. ARNH08GK3A2


1 / 220 ~ 240 / 50 25.2 5 80 Painted Steel Plate 520 x 1,080 x 330 20-15/32 x 42-27/32 x 13 94(207.2) Brazed Plate Hex 36 20 Brazed Plate Hex Twin Rotary Inverter

Max Max Min Max

Max Max Min Max

inch inch mm(inch) mm(inch) mm(inch) dB(A) dB(A) No. x mm2 No. x mm2

Male PT 1 Male PT 1 9.52(3/8) 22.2(7/8) Male PT 1 26 26 3C x CV2.5 2C x CVV-SB 1.0~1.5 R410A

inch inch mm(inch) mm(inch) mm(inch) dB(A) dB(A) No. x mm2 No. x mm2

Male PT 1 Male PT 1 9.52(3/8) 22.2(7/8) Male PT 1 43 3C x CV4.0 2C x CVV-SB 1.0~1.5 R410a EEV R134a

Refrigerant

Refrigerant

kg (lbs) C(DB) C(DB) C(DB) C(DB) % %

EEV -5C ~ 43C -20C ~ 35C -5C ~ 43C -20C ~ 43C 50 ~ 100 50 ~ 130

kg (lbs) C(DB) C(DB) C(DB) C(DB) % %

3.0 (6.6) EEV -5C ~ 43C -20C ~ 35C -5C ~ 43C -20C ~ 43C 50 ~ 100 50 ~ 130

Operation range

Operation range

Combination ratio

Combination ratio

*Notes Capacities are based on the following conditions: 1. Cooling Temperature : Indoor 27C(80.6F) DB / 19C(66.2F) WB, Outdoor 35C(95F) DB / 24C(75.2F) WB, Water Inlet 23C(73.4F) / Outlet 18C(64.4F) 2. Heating Temperature : Indoor 20C(68F) DB / 15C(59F) WB, Outdoor 7C(44.6F) DB / 6C(42.8F) WB, * Water Inlet 30C(86F) / Outlet 35C(95F), ** Water Inlet 55C(131F) / Outlet 65C(149F) 3. Piping Length : Interconnected Pipe Length = 7.5m 4. Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero. * Medium Temp. ** High Temp.

*Notes Capacities are based on the following conditions: 1. Cooling Temperature : Indoor 27C(80.6F) DB / 19C(66.2F) WB, Outdoor 35C(95F) DB / 24C(75.2F) WB, Water Inlet 23C(73.4F) / Outlet 18C(64.4F) 2. Heating Temperature : Indoor 20C(68F) DB / 15C(59F) WB, Outdoor 7C(44.6F) DB / 6C(42.8F) WB, * Water Inlet 30C(86F) / Outlet 35C(95F), ** Water Inlet 55C(131F) / Outlet 65C(149F) 3. Piping Length : Interconnected Pipe Length = 7.5m 4. Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero. * Medium Temp. ** High Temp.

126

127

Energy Recovery Ventilator is an energy efficient ventilation system, which provides fresh air and removes contaminants effectively.

134 139

eco v

eco v DX

eco v

Energy Recovery Ventilator

High Efficiency Heat Exchanger


Efficiency and comfort is ensured through the highefficiency energy recovery central core which recovers energy from the indoor air and transfers it to the fresh incoming air without mixing airstream.
Exhaust air Supply air

Bypass Ventilation
ECO V automatically switches the ventilation mode (Enthalpy Heat Exchange Mode / Bypass Mode) according to the indoor/ outdoor temperature. (Only applied to 500 CMH or above)
Enthalpy Heat Exchange Mode
[Summer / Winter] [Seasonal Change]

Bypass Mode

Damper
Air Filter Air Filter

Damper

Outdoor air

Indoor air

Interlocking with Air Conditioning System


- ECO V can be interlocked with air conditioners and controlled individually. -  This function can be operated when the system is connected with a remote control.
Cooling / Heating mode Set temperature

Flexibility of Installation
Its possible to install ECO V upside down when you need only one inspection hole.
PQRCVSL0 PQRCVSL0QW

Compulsory Exhausting System


The exhausting system using high static and sirocco fan removes contaminants effectively from indoor air. Supply and exhaust in the total heat exchanger, ECO V can filter out the impurities before supplying outdoor air air flows are completely separated and make indoor air fresh and healthy.

Outdoors Exhaust Air

Indoors Supply Air

Damper Exhaust Air Return Air

Normal installation of 2 units

Reverse installation of 1 unit (Left unit)

Inspection chamber
Top
Outdoor Air Total Heat Exchanger Supply Air

Outdoor Air

Return Air

Low

Low

Top

130

131

Energy Recovery Ventilator

Easy Cleaning and Filter Change


It is easy and convenient to change and clean the filter.
(Only applied to 500 CMH or above)

Fast Ventilation Mode


Fast ventilation mode prevents the spread of contaminants under negative indoor pressure, and makes indoor air fresh and comfortable quickly.

Only Exhausting
Supply Fan Exhausting and Supplying Simultaneously

Fast Ventilation Mode

Exhaust Fan

Eco V unit

Remove side panel


Exhausting operation causes negative indoor air pressure, and cannot fully ventilate.

CO2 Concentration Control


Using CO2 sensor, ECO V controls exhaust air flow automatically to keep indoor air fresh under settled CO2 concentration.

Remove heat exchanger

Change filer

(External Static Pressure Control)


The high static pressure fan can control the air volume depending on the length of the duct. It is also easy to control the pressure level by using the remote controller for a more flexible duct installation and easier testing.
Air Volume

L H M L

Standard Wired Remote Controller

CO2 Sensor (PES-C0RV0)

CO2 (ppm)

Closed

Windows

Windows

Open

Closed

Windows

Windows

Open

2500

OFF
1000

ON

External Static Pressure (mmAq)

10

12

Time (min)

132

133

ECO V LZ-H025GBA2 / LZ-H035GBA2 LZ-H050GBA2

ECO V LZ-H080GBA2 / LZ-H100GBA2 LZ-H150GBA2 / LZ-H200GBA2

LZ-H025GBA2 LZ-H035GBA2 Model


Nominal Capacity Power Supply Step Current Power input Air Flow ECO V Mode External Static Pressure SH/H/L SH/H/L SH/H/L SH/H/L SH/H/L CMH(CFM) /V/Hz Amps W CMH(CFM) Pa(In.wg) % % % dBA LZ-H025GBA2
250(147)

LZ-H050GBA2

LZ-H080GBA2 LZ-H100GBA2
LZ-H050GBA2
500(294)

LZ-H150GBA2 LZ-H200GBA2
LZ-H100GBA2
1,000(589)

LZ-H035GBA2
350(206) 1, 220-240, 50-60 SUPER-HIGH / HIGH / LOW

Model
Nominal Capacity Power Supply Step Current Power input Air Flow ECO V Mode External Static Pressure SH/H/L SH/H/L SH/H/L SH/H/L SH/H/L CMH(CFM) /V/Hz Amps W CMH(CFM) Pa(In.wg) % % % dBA

LZ-H080GBA2
800(471)

LZ-H150GBA2
1,500(883)

LZ-H200GBA2
2,000(1,177)

1, 220-240, 50-60 SUPER-HIGH / HIGH / LOW 2.77/2.16/1.44 360/370/165 800/800/660 (471/471/388) 200/110/60 (0.80/0.44/0.24) 79/79/82 70/70/75 65/65/70 36/34/30 2.77/2.16/1.44 360/370/165 800/800/660 (471/471/388) 200/110/60 (0.80/0.44/0.24) 36/34/30 3.41/2.91/1.76 470/385/210 1,000/1,000/800 (589/589/471) 160/90/50 (0.64/0.36/0.20) 75/75/78 66/66/71 61/61/66 37/35/31 3.41/2.91/1.76 470/385/210 1,000/1,000/800 (589/589/471) 160/90/50 (0.64/0.36/0.20) 5.6/5.4/2.9 720/540/340 1,500/1,500/1,200 (883/883/706) 200/110/60 (0.80/0.44/0.24) 79/79/82 70/70/75 65/65/70 39/37/33 5.6/5.4/2.9 720/540/340 1,500/1,500/1,200 (883/883/706) 200/110/60 (0.80/0.44/0.24) 37/35/31 Crossflow 60(132) 1,062x365x1,140(41.9x14.4x44.9) 4 250(9.84) 1 Direct-Drive 1 Direct-Drive 2 Cleanable 600x10x150(23.62x0.39x5.91) 1,056x10x212.5(41.57x0.39x8.37) PQRCVSL0 / PQRCVSL0QW PQDSB / PQDSB1 4 2 140(308) 1,313x737x1,140(51.7x29.0x44.9) 4+2 250(9.84)+350(13.77) 2 6.8/5.9/3.6 930/770/420 2,000/2,000/1,600 (1,177/1,177/942) 160/90/50 (0.64/0.36/0.20) 75/75/78 66/66/71 61/61/66 39/37/33 6.8/5.9/3.6 930/770/420 2,000/2,000/1,600 (1,177/1,177/942) 160/90/50 (0.64/0.36/0.20)

1.04/0.97/0.7 110/105/75 250/250/150 (147/147/88) 150/130/110 (0.60/0.52/0.44) 80/80/85 70/70/78 64/64/68 32/28/21 -/-/-/-/-/-/-/-/-/-/-/-/-

1.73/1.58/0.77 200/180/80 350/350/210 (206/206/124) 170/150/100 (0.68/0.60/0.40) 83/83/87 80/80/85 78/78/83 33/28/23

1.92/1.58/0.79 230/220/85 500/500/320 (294/294/124) 150/100/50 (0.60/0.40/0.2) 75/75/79 72/72/77 70/70/75 34/35/25 SUPER-HIGH / HIGH / LOW 1.92/1.58/0.79 230/220/85 500/500/320 (294/294/124) 150/100/50 (0.60/0.40/0.2) 34/35/25

Temperature Exchange Efficiency SH/H/L Heating(SH/H/L) Enthalpy Exchange Efficiency Cooling(SH/H/L) Noise Level (Sound Level, 1.5m) SH/H/L Step Current Power input Bypass Mode Air Flow External Static Pressure Noise Level (Sound Level, 1.5m) Heat Exchanger Net Weight Dimension Duct Work Supply Air Fan Exhaust Air Fan Filters Remote Controller Dry Contact Type WxHxD Qty Size() Qty Type Qty Type Qty Type Size(WxHxD)

Temperature Exchange Efficiency SH/H/L Heating(SH/H/L) Enthalpy Exchange Efficiency Cooling(SH/H/L) Noise Level (Sound Level, 1.5m) SH/H/L Step Current Power input Bypass Mode Air Flow External Static Pressure Noise Level (Sound Level, 1.5m) Heat Exchanger Net Weight Dimension Duct Work Supply Air Fan Exhaust Air Fan Filters Type WxHxD Qty Size() Qty Type Qty Type Qty Type Size(WxHxD)

SUPER-HIGH / HIGH / LOW

dBA kg(lb) mm (Inch) EA mm (Inch) EA EA EA mm (Inch) W

Crossflow 320(70.5) 750x250x680(29.52x9.84x26.77) 4 150(5.91) 1 Direct-Drive 1 Direct-Drive 2 Cleanable 600x10x150(23.62x0.39x5.91) PQRCVSL0 / PQRCVSL0QW PQDSB / PQDSB1 855x10x166(33.66x0.39x6.54) 200(7.87) 44(97) 988x273x1,014(38.9x10.75x39.92)

Remote Controller Dry Contact

dBA kg(lb) mm (Inch) EA mm (Inch) EA EA EA mm (Inch) W

Notes: 1. eco V Mode - Enthalpy Heat Recovery Ventilation mode 2. Noise level : - The operating conditions are assumed to be standard. - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.

Notes: 1. eco V Mode - Enthalpy Heat Recovery Ventilation mode 2. Noise level : - The operating conditions are assumed to be standard. - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.

Wired Remote Controller


Standard Type Standard Type Standard Type

Wired Remote Controller


Standard Type

PQRCVSL0

PQRCVSL0QW

PQRCVSL0

PQRCVSL0QW

134

135

LZ-H025GBA2
[ Ventilation ]
400 90%

LZ-H025GBA2
<Efficiency>
External Static Pressure [Pa]
Tem p

500 400

[ Ventilation ]
Exchange Efficiency[%]

<Efficiency>
90% 80% 70% 60% 50% 40% 0
eratu re Ex chan ge Eff halp icienc yE y xch ang eE Enth ffic alpy ien cy Exc (he han atin ge E g) ffici enc y (c ooli ng) Temp

External Static Pressure [Pa]

Exchange Efficiency[%]

300 200
High Super-High

80% 70% 60% 50% 40%

En

eratu

tha

re E

lpy

xch

Ex

ang

Ent

ch

e Eff

an

icie

ge

ncy

Super-High

Enth

Eff

icie

alpy

Exch

nc

300 200 100 0 0

y(

High Low

ange

he

Effic

atin

ienc

g)
)

y (co

100

oling

Low

100

200

300

400

500

100

200

300

400

500

200

400

600

800

1000

1200

200

400

600

800

1000

1200

Air Volume[m3/h]

Air Volume[m3/h]

Air Volume[m3/h]

Air Volume[m3/h]

LZ-H035GBA2
[ Ventilation ]
External Static Pressure [Pa]
400 300
Super-High

LZ-H035GBA2
Tempe
Enthal py Exch

rature

External Static Pressure [Pa]

90%

<Efficiency>
Excha nge E fficienc y

450 400 350 300 250 200 150 100 50 0

[ Ventilation ]

90% 85%

<Efficiency>
Te mp era tur e

Exchange Efficiency[%]

80% 70%

ange Ef

ficienc

y (hea

ting)

High Low

Exchange Efficiency[%]

Super-High

80% 75% 70% 65% 60% 55% 0 200

200 100 0

High Low

Enth

60% 50% 40% 0 100

alpy

Exch

ange

Effic

ienc

y (co

oling

Ex cha En nge E ntth rE ha E allp ffic fic py ie yE ie nn Ex cg xc yy ch ha En an ng ge tha e rEE lpy f f f f ic ic Ex ie ie ch nn cg an y( yH (H ge ee atin Eff g) icie nc y(C oo lin g)
400 600 800 1,000 1,200 1,400

100

200

300

400

500

Air Volume[m3/h]

200

300

400

500

200

400

Air Volume[m3/h]

600

800

1,000

1,200

Air Volume[m3/h]

Air Volume[m3/h]

LZ-H050GBA2
[ Ventilation ]
400 90%

LZ-H050GBA2
External Static Pressure [Pa]

<Efficiency>
Tem p

500 400 300

[ Ventilation ]
Exchange Efficiency[%]

90%
Super-High

<Efficiency>
Temp
Enth

erature
Exc

External Static Pressure [Pa]

Exchange Efficiency[%]

300
Super-High High

80% 70% 60% 50% 40% 0

Enth

eratu

Enth

alpy

re E

80% 70% 60% 50% 40% 0 400

alpy

Exchan
ge E

ge Eff
ncy

alpy

Exch

xch

han

iciency
(hea

Exch

ange

ange

Effic

200 100
Low

icie ncy ienc y (he ating ienc ) y (co oling )

ang e Eff

Enth

fficie

Effic

High

alpy

Exch

ange

ting

200 100 0 0 400 800

Effic

ienc

y (co

Low

oling

1200

1600

2000

0 0

100

200

300

400

500

600

700

800

100

200

300

400

500

600

700

800

Air Volume[m3/h]

Air Volume[m3/h]

800

1200

1600

2000

Air Volume[m3/h]

Air Volume[m3/h]

LZ-H025GBA2
450

[ Ventilation ]

90% 85%

<Efficiency>
Tem per atu re E

External Static Pressure [Pa]

400 350 300 250 200 150 100 50 0 0 500 1,000 1,500 2,000 2,500

Exchange Efficiency[%]

High Low

Super-High

80% 75% 70% 65% 60% 55% 0 500

En

tha

xch

lpy

ang

En

Ex

eE

tha

cha

fficie

lpy

nge

ncy

Ex

cha

Eff

icie

ng

ncy

eE

(He

ffic

atin

ien

g)

cy(

Co

olin

g)
2,500

Air Volume[m3/h]

1,000

1,500

2,000

Air Volume[m3/h]

136

137

Energy Recovery Ventilator with DX Coil

ECO V DX LZ-H050GXH0 / LZ-H080GXH0 LZ-H100GXH0

Providing Cool / Warm Fresh Air


ECO V DX has some air conditioning funtions. During the summer, it can transform outdoor warm air into cool air for indoors, and it can prevent cold drafts during the winter by supplying warm air.

Model
Cooling Fresh Air Conditioning Load Heating Temperature Exchange Efficiency SH/H/L Cooling (SH/H/L) Enthalpy Exchange Efficiency Heating (SH/H/L) Heat Exchange Mode (SH/H/L) Air Flow Rate Bypass Mode (SH/H/L) Fan External Static Pressure (SH/H/L) System Humidifier Amount Feed Water Pressure Heat Exchange Mode Noise Level Bypass Mode Refrigerant Power Supply Heat Exchange Mode (SH/H/L) Power Input (Norminal) Bypass Mode (SH/H/L) Heat Exchange Mode (SH/H/L) Nominal Running Current (RLA) Bypass Mode (SH/H/L) Dimensions WxHxD Net Weight Liquid Gas Water Pipe Connection Drain Connection Duct Diameter Remote Controller Dry Contact(1 contact point) Dry Contact(2 contact point) kW kW % % % CMH CMH Pa kg/h Mpa dB(A) dB(A) /V/Hz kW kW A A mm kg(lbs) mm mm mm mm mm

LZ-H050GXH0
4.93 6.73 86/86/87 68/68/69 76/76/77 500/500/440 500/500/440 160/120/100 2.7 0.02~0.49 38/36/33 39/37/34

LZ-H080GXH0
7.46 9.8 84/84/86 64/64/66 74/74/76 800/800/640 800/800/640 140/90/70 Natural Evaporating Type 4 0.02~0.49 39/37/34 40/38/35 R410a 1,220~240,50

LZ-H100GXH0
9.12 11.72 82/82/84 60/60/63 71/71/73 1,000/1,000/820 1,000/1,000/820 110/70/60 5.4 0.02~0.49 40/38/35 40/38/35

Cooling

Heating

Total Air Conditioning Solution


ECO V DX can be used as a Total Air Conditioning Solution. It can control condition of incoming air with the DX coil and humidifier for making comfortable indoor air. In the summer, ECO V DX controls the air indoors by cooling and dehumidifying incoming air. In winter, it can provide warm air by heating and humidifying the incoming air.
Heat exchange DX Coil Humidification Exhaust Air Supply Air

0.25/0.2/0.15 0.25/0.2/0.15 1.5/1.3/1 1.5/1.3/1

0.42/0.35/0.25 0.42/0.35/0.25 2.5/2/1.5 2.5/2/1.5 365x1,667x1,140 105 6.35 12.7 6.35 25.4 250 PQRCVSL0 / PQRCVSL0QW PQDSB / PQDSB1 PQDSBC

0.48/0.42/0.27 0.48/0.42/0.27 3.6/3.2/2.3 3.6/3.2/2.3

Outdoor Air

Return Air

Interlocking with MULTI V


ECO V DX can be interlocked with MULTI V. It can be controlled individually by a wired remote controller connected to MULTI V indoor units. Indoor Units eco V DX

Notes: 1. eco V Mode - Enthalpy Heat Recovery Ventilation mode 2. Noise level : - The operating conditions are assumed to be standard. - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.

Wired Remote Controller


Standard Type Standard Type

Outdoor

PQRCVSL0

PQRCVSL0QW

138

139

ECO V DX LZ-H050GXN0 / LZ-H080GXN0 LZ-H100GXN0

Model
Cooling Fresh Air Conditioning Load Heating Temperature Exchange Efficiency SH/H/L Cooling (SH/H/L) Enthalpy Exchange Efficiency Heating (SH/H/L) Heat Exchange Mode (SH/H/L) Air Flow Rate Bypass Mode (SH/H/L) Fan External Static Pressure (SH/H/L) System Humidifier Amount Feed Water Pressure Heat Exchange Mode Noise Level Bypass Mode Refrigerant Power Supply Heat Exchange Mode (SH/H/L) Power Input (Norminal) Bypass Mode (SH/H/L) Heat Exchange Mode (SH/H/L) Nominal Running Current (RLA) Bypass Mode (SH/H/L) Dimensions WxHxD Net Weight Liquid Gas Water Pipe Connection Drain Connection Duct Diameter Remote Controller Dry Contact(1 contact point) Dry Contact(2 contact point) kW kW % % % CMH CMH Pa kg/h Mpa dB(A) dB(A) /V/Hz kW kW A A mm kg(lbs) mm mm mm mm mm

LZ-H050GXN0
4.93 6.73 86/86/87 68/68/69 76/76/77 500/500/440 500/500/440 180/150/110

LZ-H080GXN0
7.46 9.8 84/84/86 64/64/66 74/74/76 800/800/640 800/800/640 170/120/80 -

LZ-H100GXN0
9.12 11.72 82/82/84 60/60/63 71/71/73 1,000/1,000/820 1,000/1,000/820 150/100/70

39/37/35 39/37/35

41/38/36 41/38/36 R410a 1,220~240,50

41/39/36 41/39/36

0.25/0.2/0.15 0.25/0.2/0.15 1.5/1.3/1 1.5/1.3/1

0.42/0.35/0.25 0.42/0.35/0.25 2.5/2/1.5 2.5/2/1.5 365x1,667x1,140 98 6.35 12.7 25.4 250 PQRCVSL0 / PQRCVSL0QW PQDSB / PQDSB1 PQDSBC

0.48/0.42/0.27 0.48/0.42/0.27 3.6/3.2/2.3 3.6/3.2/2.3

Notes: 1. eco V Mode - Enthalpy Heat Recovery Ventilation mode 2. Noise level : - The operating conditions are assumed to be standard. - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.

Wired Remote Controller


Standard Type Standard Type

PQRCVSL0

PQRCVSL0QW

140

141

Fuction- iconS
Mirror Standard Wall mounted Console 4way Cassette 2 way Cassette 1 way Cassette Low Static Built-in High Static Ceiling & Floor Ceiling Suspended Floor Standing

NEO Plasma Air Purifying System Jet Cool

Dehumidification

Hot Start
(Heat pump only)

Child Lock Function


(Wired remote controller only)

Soft Dry Operation Mode

Low Standby Power

Group Control
(Wired remote controller only)

Auto Changeover
(MULTI V SYNC model only)

Auto Clean Sleep Mode Auto Operation Auto Restart


143

4-Way Air Deflection

Swirl Swing

Weekly Program
(Wired remote controller only)

Two Thermistor Control


(Wired remote controller only)

Changable Panel

Second Remote Control

142

ACCESSORIES
Control system that understands both the installer and users.

v-net & accessory

148 152 166

remote CONTROLS

central CONTROLLERS

ACCESSORIES

2013 Line-up

Remote Controller

Central Controller

Central Controller

Gateway

AHU Kit

Electronic Accessories

Wired Remote Controller

Wireless Remote Controller

Simple Central Controller

AC Smart, Option Kit & 128 Units Expansion Kit

ACP & AC Manager Plus

Building Network Unit

PI 485 & DO Kit


Comm. kit

PDI Dry Contact Variable Water Flow Control Kit Independent Power Module CO2 Sensor Remote Temperature Sensor Cool/Heat Selector AHU Comm.Kit & EEV Kit
EEV kit

Standard

Deluxe

Simple

PRCKA0 PRDCA0

PI 485

PQCSZ250S0 PQWRHDF0 PQRCUDS0


AC EZ

PQCSW320A1E
AC Smart ll

PQNFB16A1 PQCPC22NO
(ACP Standard)

(LONWORKS)

PMNFP14A1 PHNFP14A0 PSNFP14A0 PRLK048A0 PRLK096A0

AHU Control Kit AHU Expansion Kit Stopper Valves Heat Recovery Unit

PQRCVSL0

(White)

PQRCVCL0Q
(Black/Simple)

PQCPC22AO
(ACP Premium)

PQCSSA21EO
(AC Manager Plus)
Option Kit

PQCSE341A0 PQCSE342A0 PQWRHQ0FDB PQRCVSL0QW PQRCUDSOB


(Blue)

DO Kit

PQNFP00T0 PQNFB17B0
(BACnet/Modbus)
Control kit

Y Branch and Header Branch


PRCKD21E PRCKD41E

Piping Accessories

PQRCVCL0QW
(White/Simple)

Expansion Kit

PQCSE440U0
Expansion kit

PQRCUDSOS
(Silver)

PQRCHCA0Q

(Black/Simple for Hotel)

AC Smart Premium

PATX13A0E PATX20A0E PATX25A0E PATX35A0E PATX50A0E

& Accessory

PQRCHCA0QW

(White/Simple for Hotel)

PQCSW421E0A

146

147

Standard Wired Remote Controller


Providing easy control of one or a group of indoor units to various applications.

Deluxe Wired Remote Controller


Touch screen with a premium design for high end interior designs.

PQRCVSL0 PQRCVSL0QW

PQRCUDS0 PQRCUDS0B PQRCUDS0S

PQRCVSL0QW (White)

PQRCVSL0 (Black)

PQRCUDS0 (White)

PQRCUDS0B (Blue)

PQRCUDS0S (Silver)

Features Features
Category
Operating mode Max. no. of indoor units On / Off LED Room temp. Fan / Plasma / Swirl / Heater Vane control(Louver direction) / Auto swing / Fan auto E.S.P function Reservation Timer function Child lock Electric failure compensation Wireless remocon receiver Main/Sub setting of indoor units (For override function) 2 Controllers to 1 indoor unit Group and central control at the same time Ventilation mode setting Rapid ventilation Power saving ventilation Size(mm) Backlight Unit
Applicable for Multi V II and III series. Applicable for ECO V II series.

Category PQRCVSL0 / PQRCVSL0QW


On/Off / Fan speed / Mode / Temp. 16 indoor units

PQRCUDS0 / PQRCUDS0B / PQRCUDS0S


On/Off / Fan speed / Mode / Temp.


On/Off / Weekly / Simple / Sleep / Holiday

Operating mode Touch screen / LCD back_light Room temp Fan / Plasma / Swirl / Heater Vane control(Louver direction) / Auto swing E.S.P function Reservation Timer function Child lock
Refer to each model PDB for applicable models.


Weekly / Simple


Max 3 hours

120 x 121 x 16

& Accessory

Terminal Block included. (Applied to models produced since 10 Nov.) Refer to each model PDB for applicable models.

148

149

Simple Wired Remote Controller


A simple way to control office or hotel systems in a compact design.

Wireless Remote Controller


Wireless control to operate air conditioners more conveniently.

Simple

PQWRHDF0 PQWRHQ0FDB

PQRCVCL0QW (White) PQRCVCL0Q (Black)


Simple for Hotel

PQRCHCA0QW (White) PQRCHCA0Q (Black)


PQRCVCL0QW PQRCHCA0QW PQRCVCL0Q PQRCHCA0Q

PQWRHDF0

PQWRHQ0FDB

Features
Category
Operation mode Room temp Child lock Mode change Back Light
Refer to each model PDB for applicable models.

Features
PQRCVCL0Q / PQRCVCLOQW
On/Off / Fan speed / Mode / Temp.

PQRCHCA0Q / PQRCHCA0QW
On/Off / Fan speed / Temp.

Category
Operating mode Room temperature checking Chaos swing / Jet cool On/Off timer Sleep mode auto Main / Sub setting of indoor units (For override function)
Applicable for MULTI V II and III series. Refer to each model PDB for applicable models.

PQWRHDF0 / PQWRHQ0FDB
On/Off / Fan speed / Mode / Temp


Cooling / Heating / Fan / Dehumidify / Auto


Only changeable by central controller

Model Name & Applicable Models


& Accessory
Model
PQWRHDF0 / PQWRHQ0FDB
Combination with other remote controllers for various indoor units.

Type
H/P

CST, SRAC, CVT, Duct*, Floor Standing


* All Duct products can be controlled through wireless remote controller when wired remote controller is installed.

150

151

AC EZ
In addition to On/Off control, more functions such as operation mode, fan speed, and scheduling can be run and monitored.

NAME AND DESCRIPTION OF THE SYSTEM


LCD Display Control mode select button

PQCSZ250S0

Total On/Off control

Individual Indoor On/Off control and LED Display

Detailed Function control part

Lock control

Features
Category
Max. Indoor unit to control Individual Control Lock function Mode change Schedule Ventilation control Display(All Indoor status indication) Size(mm) Power(V)

Combination
PQCSZ50S0
32 Indoor Units On/Off / Operation Mode / Fan Speed / Temp Central Cooling / Heating / Fan / Dehumidification / Auto 8 event schedule/day On/Off / Ventilation Mode / Rapid Ventilation Operation, Set temp, Room Temp, Schedule 190x120x17 DC 12V

MULTI V III Heat Pump MULTI V III Heat Recovery MULTI V PLUS II MULTI V SYNC II MULTI V SPACE II MULTI V Water II MULTI V MINI (ARUN40GS2A only needs PI485)

PQCSZ250S0 PI 485 AC 220V


PMNFP14A1(Max 64 indoor units)

MULTI, Single CAC

PI 485
ECO V
PHNFP14A0

& Accessory

152

153

Option Kit & 128 Units Expansion Kit


Interactive interface with LCD touch screen for control up to 128 units with the expansion kit directly on the touch screen or via PC & web access.
AC Smart II New GUI
It is more easy to use and control the products.

PQCSW320A1E
128 Units Expansion Kit AWHP / ECO V DX unit control
It is possible to control the unit (Indoor unit, ventilator, On/Off, AWHP, ECO V DX, Hydro Kit) and register the units.

PQCSE440U0
Option Kit

PQCSE341A0 PQCSE342A0 Features

Indoor Unit 1 Outdoor Unit

Indoor Unit 2

Indoor Unit 3

ECO V DX

Hydro Kit

ECO V

ON/Off Unit (DO Kit)

AWHP Outdoor Unit

AWHP Indoor Unit

Easy Control Web Access


- Remote Management - Error Report via E-mail

7 Touch Screen / GUI Direct Connect to LGAP

- Funtion Lock - Lock Schedule

E-mail Function
Comfort Control
- Automatic H/C Changeover - Temperature Limit - Temperature Range Restriction - Time Limit Control

Multi / SCAC / MULTI V MINI (ARUN40GS2A only needs PI485)

Multi Language
- English, Italian, Spanish, French, German, Dutch, Russian

AC Smart II can automatically send an email to any email adress in case of error occurs. The error code and time will be written. Thanks to this function, servicing is more convenient.

Screen Saver

Option Kit Control


AC Smart II additionally provides various functions for users (Option Kit sold separately.)

DI
Easy Software Upgrade by USB
USB Option Kit

RS485
Light Pump Moter etc

DO Kit

PQNFP00T0

AC Smart II Option Kit Model Name : PQCSE341A0 / PQCSE342A0


LGAP

Operation Report
- Operating Time, Percentage, History
128 Indoor units Expansion Kit PQCSE440U0

Emergency Interlock
- Forced Off

Multiple Local Controllers


- Master / Slave

Remote Controller Restriction Automatic Setting A/C and Vent.

Description AC Smart II additionally provides various convenient functions for the users. These additional functions are provided on an SD card. When the SD card inserted into the AC Smart II, the option functions can be used. Option Functions - Web schedule + Power consumption statistics function (PQCSE342A0) - Web schedule function (PQCSE341A0) Web based schedule setting function  By using the web server function of the AC SMART II, you can set and apply the schedule from remote locations. The administrator can manage the schedule of AC SMART II through the network regardless of location and reduce any unnecessary operations of the unit by using the schedule functions.  Power consumption statistics function You can view the power consumption information of the air conditioner. The power consumption is provided through various methods including total usage, usage by period, monthly/daily usage etc. Datas can be saved in excel format to an USB key. By using the statistics information, the administrator can effectively analyse and manage the energy usage. To use the power consumption statistics function, the PDI and watt-meter to measure the power consumption must be connected to AC SMART II.

Schedule Wizard Function


The Schedule Pattern Wizard can configure the operation of units on a weekly or daily basis. The pattern created through the wizard can be applied to the group as a schedule.

& Accessory

Web Schedule Function

1. Select schedule pattern type

2. Add/Edit schedule pattern

3. Enter schedule pattern name

4. Edit schedule pattern

PDI Function

154

155

AC Smart Premium
New AC Smart Premium provides a user-friendly GUI with 10.2 inch screen
Improved web functions / Intuitive GUI design
 ith its user-friendly Web GUI,  W AC Smart Premium shows current status of air-conditioners and summary of schedule.

Visual Navigation
Floor plan (jpg format) can be edited according to the air-conditioners location and shows the status.

PQCSW421E0A

Home Screen

Energy report
AC Smart premium shows statistical data about indoor units (Operation hours / Power consumption).

AHU Control
AC Smart Premium provides various control functions to users.

Features (Changes from the previous model)


 Visual Navigation User friendly GUI Screen size up(10.2inch) and Resolution(1024*600) 2 D/I and 2 D/O ports for interlocking function Energy bill calculation function 2 Point Setback 2 Point Auto Changeover E-mail of Statistics

Control / Monitoring Controls and monitors the operation status of the air conditioner / ventilator devices.

 tatistics S Displays power consumption or usage of the air conditioners.

Combination
It is possible to control the unit (IDU, Ventilator, on/off, AWHP, Hydro Kit, ECO V DX, AHU) and register the units.

Schedule Operates the air conditioners, ventilators, AHU, AWHP , Hydro Kit and DO Kit connected to AC Smart Premium according to the schedule.

Report Displays the history of any errors that have occurred in the air conditioners. 

Indoor Unit 1 Outdoor Unit

Indoor Unit 2

Indoor Unit 3

ECO V DX

Hydro Kit

Automation control - Peakpower : Sets a peak operation rate so that the air conditioner doesnt exceed the set value. - Demand : Sets the demand power control function that monitors power consumption of the air conditioner indoor units in real time, so that the target power consumption amount is not exceeded.

Device Setting Registers, modifies or deletes air conditioners, ventilators, AHU, AWHP, Hydro Kit and DO Kit connected to AC Smart Premium.

& Accessory

ECO V

ON/Off Unit (DO Kit)

AWHP Outdoor Unit

AWHP Indoor Unit

Multi / SCAC / MULTI V MINI (ARUN40GS2A only needs PI485)

 onfigure C General contents, user accounts, network, E-mail account, set up TMS contents etc.

AHU

156

157

(Standard / Premium)
With its Linux based web server, users can control up to 256 indoor units or 128 ECO V units for functions such as temperature setting, schedule, peak, power control, etc.
Standard

Combination
MULTI V III Heat Pump MULTI V III Heat Recovery

PQCPC22N0
Premium

PQCPC22A0

PQCPC22N0 (ACP Standard) PQCPC22A0 (ACP Premium)

MULTI V PLUS II MULTI V SYNC II MULTI V SPACE II MULTI V Water II MULTI V MINI (ARUN40GS2A only needs PI485)

PI 485
Product Name External I/O Port No. ACP Standard D/I 2, D/O 2 Air conditioner/ ECO V/ ECO V DX/ AWHP, Hydro Kit ACP Premium D/I 4, D/O 10 Air conditioner/ ECO V/ ECO V DX/ AWHP/ Hydro Kit AHU

AC 220V

Internet

MULTI Single CAC

PMNFP14A1 (Max. 64 indoors)

Interfaceable Products

PI 485 PHNFP14A0

ECO V

Features
Category
Max.no. of indoor units Control / Monitoring Schedule management Lock function Temperature range restriction Temperature limit function Auto Changeover function History function Peak control PDI monitoring Auto Address Setting Function Statistics function Peak Priority funtion ECO V, ECO V DX Control

PQCPC22N0 / PQCPC22A0
256 indoor units


Temperature 18C ~ 30C

or
AC EZ AC Smart

or
AC Smart Premium

(With AC Manager Plus only) (With AC Manager Plus only)


Error history

Need of PDI

Control / Monitor

New Function Upgrade

Remote Access

Various Controller Combination

& Accessory

Schedule

Stand Alone Operation Power Proportional Peak Power Control

158

159

Plus
Provides efficient control and monitoring system for up to 8,192 indoor units by connecting 32 ACPs.

Combination
MULTI V III Heat Pump MULTI V III Heat Recovery

PQCSSA21E0

AC Manager Plus PQCSSA21E0


PI 485 AC 220V

MULTI V PLUS II MULTI V SYNC II MULTI V SPACE II MULTI V Water II MULTI V MINI (ARUN40GS2A only needs PI485)

Features
Category
Max.no. of indoor units Control / Monitoring Schedule management Lock function Temperature range restriction Temperature limit function Auto Changeover function History function Peak control PDI monitoring Printing function Statistics function Time limit function ECO V, ECO V DX Control Peak Priority function Interlocking function AHU Control Function Hydro Kit, AWHP Control

HUB

DC Comm, Line PMNFP14A1 (Max. 64 indoors)

MULTI Single CAC

PQCSSA21E0
8,192 indoor units (32 ACP)

Internet


Mode/Temp/Fan speed/Total

PI 485 Max. 32 ACP PHNFP14A0

ECO V


Monitoring & Error history

Need of PDI

Plus Application
Multi Area Management The product specially designed for multi area management. -Central control & monitor Max. 8,192 indoor units & Max. 32 ACP

Control / Monitor

Visual Navigation

Various Controller Combination

Plus

& Accessory

Fire Alarm

Schedule

Max. 8,192 Indoor

Stand Alone Operation Power Proportional

Peak Power Control

Korean reference site.

ACP

AC Manager Plus

160

161

BNU-LW BMS Gateway


Interface between BMS and LG Air-Conditioners LonMark certified : Operation system based on LNS( Network Service)

BNU-BN BMS Gateway


Interface between BMS and LG Air-Conditioners BTL certified : Operation system based on BACnet Service.

PQNFB16A1

PQNFB17B0 PQNFB17C0

PQNFB17C0 (New Model)

PQNFB17B0

PQNFB17C0 (New Model)

Features
  Connection to using LONTALK protocol and Controlling LG Air-conditioner protocol On/Off command Operation mode setting  Process ability Fan Speed setting - 64 units (A/C, ECO V) Lock setting - Valid address for each unit : 0x00 ~ 0x3F Air flow setting  Self installation verification function using internet Set temp. setting (Web server included) - Setting gateway - Diagnosis of communication status on LG Air-conditioner network User mode setting (for only ventilator)  Connection to remote total management system (LG system) LonMark International certified.
Monitoring items
On/Off status report Operation mode status report Fan Speed status report Lock status report Air flow status report Set temp. status report Current Space temp. status report Error status report User mode status report (for only ventilator)

2013. 4 / BACnet New model   New tool, Application for 1F, Port no. of BACnet setting function A/C, ECO V, ECO V DX, AWHP or Hydro Kit 

Features
Embedded web control function in BACnet one can access the air conditioner and external devices through internet. It can control 256 indoor units. (A/C, ECO V or ECO V DX)  External devices such as fire alarm, motion detectors can be connected to gateway and their function can be interlinked with airconditioner operation. Tested by an official BACnet Testing Laboratory for BTL Mark. Support Modbus-TCP Protocol between BMS and BACnet gateway.
Controlling
On/Off command Operation mode setting Fan Speed setting Lock setting Air flow setting Set temp. setting
-

Monitoring items
On/Off status report Operation mode status report Fan Speed status report Lock status report Air flow status report Set temp. status report Current Space temp. status report Error status report User mode status report (for only ventilator)

Combination Combination
Network
LON comm. line BMS system Available with all Multi V series LGAP applied Air-conditioner

User mode setting (for only ventilator) Accumulator power distribution status report Upper limit temp. status report Upper limit temp. setting Low limit temp. status report Low limit temp. setting Mode lock status report Mode lock setting AC operation mode setting (ECO V DX only) AC operation mode status report (ECO V DX only) AC On/Off status report (ECO V DX only) AC On/Off command (ECO V DX only)

Network

BMS system

Lighting control

Remote checking

Utility control

Lighting control

Remote checking

Utility control

Indoor unit : Max. 64 units (Air-conditioner & ventilation) Indoor address : 00 ~ 3F

Other LON devices

Indoor unit : Max. 64 units (Air-conditioner & ventilation) Indoor address : 00 ~ 3F

Other devices

MULTI V III Heat Pump MULTI V III Heat Recovery MULTI V PLUS II MULTI V SYNC II MULTI V SPACE II MULTI V Water II MULTI V MINI (ARUN40GS2A only needs PI485) MULTI Single CAC

MULTI V III Heat Pump MULTI V III Heat Recovery MULTI V PLUS II MULTI V SYNC II MULTI V SPACE II MULTI V Water II MULTI V MINI (ARUN40GS2A only needs PI485) MULTI Single CAC

& Accessory

BNU-LW PQNFB16A1

PI 485

AC 220V

BNU-BN PQNFB17B0

PI 485

AC 220V

PMNFP14A1 (Max. 64 indoors)

PMNFP14A1 (Max. 64 indoors) PI 485 ECO V PHNFP14A0


AC Smart Premium

or
AC Smart AC Smart Premium

PI 485 PHNFP14A0

ECO V

or
AC Smart

Available with all Multi V series LGAP applied Air-conditioner

162

163

PI 485
PI 485 converts the air conditioner's protocol to the RS485 protocol for the central controller.

DO Kit
Connected between AC Manager Plus (or ACP, AC Smart) and external devices, which can switch On/Off devices such as light, pump, motor, etc.

PMNFP14A1 PHNFP14A0 PSNFP14A0

PQNFP00T0

Features
Model name : PMNFP14A1 Power : Single phase AC 220V 50/60Hz 1 for each outdoor unit (max 64 indoor units) - MULTI V Mini(ARUN40GS2A only needs PI485) - SCAC(standard and H-inverter) - MULTI - AWHP

Features
 When the product input is less or equal to 25A
(The device is controlled by turning On/Off the power supply line of the product.)
BUS_A BUS_B

1. Pull out the power or shut down the breaker. 2. Connect the power line from the breaker to the additional relay cable. 3. Connect the device power line to the additional relay cable. 4. Finish the connected area with the insulating tape.
AC input power (220V, 50Hz) and breaker L N

AC Manager Plus

CN_COMM

1 2 3 4

Light
CN_POWER

Pump

Wiring the earth line L N AC input power (220V, 50Hz)

Model name : PHNFP14A0 Power : Connected with the indoor units 1 for each unit - Eco V

 When the product input is greater or equal to 25A


(The device is controlled by turning On/Off the indoor/outdoor communication line.)
1. Pull out the power or shut down the breaker. 2. Cut the communication line 3. Connect the cut communication line to the additional relay cable. 4. Finish the connected area with the insulating tape.

BUS_A BUS_B AC input power (220V, 50Hz) and breaker L N

AC Manager Plus

CN_COMM

1 2 3 4

Communication line
CN_POWER

Light

Pump

Model name : PSNFP14A0 Power : Connected with the indoor units 1 for each indoor unit - Non-inverter products
Provided with a case to be installed on the exterior.

Wiring the earth line L N AC input power (220V, 50Hz)

When the product input is greater than or equal to 25A


(The device is controlled by turning On/Off the power supply line of the product thrue a field-supplied relay)
1. Pull out the power or shut down the breaker. 2. Connect the power line from the breaker to the additional relay cable. 3. Connect the field-supply relay power line to the additional relay cable. 4. Connect the device power line to the field-supply relay. 5. Finish the connected area with the insulating tape.

& Accessory

BUS_A BUS_B AC input power (220V, 50Hz) and breaker L N AC input power (220V, 50Hz) and breaker N L
Fleldsupplled relay
CN_COMM
1 2 3 4

MULTI V II & III series dont need any other PI 485 because MULTI V II & III series have PI 485 in its outdoor unit PCB.

AC Manager Plus

Light
CN_POWER

Pump

Wiring the earth line L N AC input power (220V, 50Hz)

164

165

PDI (Power Distribution Indicator)


For multi indoor units connected to an outdoor unit, the individual units total system power consumption can be displayed on the device. This system can also be connected to a remote metering system.

Combination
Independent operation of PDI

PQNUD1S00

 Multi V PLUS II / Multi V SYNC II / Multi V III / Multi V WATER II / Multi V SPACE / Multi V MINI
Watt meter

3 380VAC or 1 220VAC
PDI

Pulse type
1 220VAC

1 220VAC

Multi V (PI 485 is embedded at the Outdoor Unit)

Features
 Accumulated total power consumption indicated Accumulated/Current power consumption of each indoor unit indicated. Accumulated power consumption by month indicated Max. connectable no. of indoor units : 64 indoor units 1 PDI per 1 outdoor unit Power failure-proof function : Data back up on EEPROM even if power turns off Connectable to PC based central controllers Simple connection with the remote metering system (RS485 approach) Power distribution indication formula

Watt meter

Multi

3 380VAC or 1 220VAC
PDI Pulse type 1 220VAC PMNFP14A1(Max.64indoors)

PI 485

Multi Outdoor Unit

Power used per room =

Total power consumed for an external unit

weight by room total weight

Operation with other central controllers


3 380VAC or 1 220VAC
PDI

Watt meter

Weight by room: Weight calculated based on the temperature set by room, mode and operating time.

1 220VAC

Multi V Outdoor Unit


Watt meter

3 380VAC or 1 220VAC
PDI

& Accessory

Multi V Outdoor Unit

or
ACP AC Smart

or
AC Smart Premium

166

167

PDI Premium
For multi indoor units connected to an outdoor unit, the individual units total system power consumption can be displayed on the device. This system can also be connected to a remote metering system.
Error display
Shows accumulated power consumption of the system.

PQNUD1S40

ERROR - 01 N O C O M M U N I C AT I O N with airconditioner idu address [ 0 0 - 0 7 ] ERROR - 02 NO SIGNAL FROM WHM1

If communication with the product is not smooth

If no power detection signal is available

Features
Connection to max 8 outdoor. Accumulated total power consumption of outdoor and indoor unit. Accumulated / Current Power Consumption of each indoor unit. Max 128 indoor units. RS-485 type wattmeter can be interlocked. Data Back up.

Combination
 Using Pulse Type Wattmeter : Independent operation of power indicator

Power in single phase 50Hz 220V

Watt meter Pulse Signal

Pulse Signal

RS485 (LGAP)

Watt meter

Pulse Signal

Power in 3 phase 4 win 50Hz 220V

Instantaneous power screen


Shows the estimated value based on one minute power consumption.
Wattmeter number Overall instantaneous power of P(1) wattmeter Instantaneous power of each applicable indoor unit
Power cable of indoor unit

Each indoor unit number

Total accumulated power consumption display


Shows accumulated power consumption of the system.

& Accessory

Wattmeter number
ACP

or
AC Smart

or
AC Smart Premium

Overall accumulated power of P(1) wattmeter Accumulated power of each applicable indoor unit

Each indoor unit number

168

169

Dry Contact
Connection between an indoor unit and external devices to control various functions.

Dry Contact
Connection between an indoor unit and external devices to control various functions.

PQDSA(1) PQDSB(1) PQDSBC Features


Category
Contact point Power input Voltage / Non voltage input On/Off control Lock / Unlock Fan speed setting Thermo off Energy saving Temperature setting Error monitoring Operation monitoring

PQDSBNGCM1

Features
PQDSA/ PQDSB
1 Control point AC 220V from outside power source

PQDSA1/ PQDSB1
1 Control point AC 24V from outside power source

PQDSBC
2 Control points DC 5V&12V from indoor unit PCB

Category
Dimensions Contact Point Voltage / Non voltage input On/Off control Mode control Fan Speed Setting Thermo off Error Monitoring Operation monitoring Contact (output) Rotary switch 1 Rotary switch 2

PQDSBNGCM1
105 x 78 x 35 mm 8 contact point (Cool, Heat, Fan) (Low, Middle, High) 2 contact (operating, error) Operating set temp selection Operating logic selection

Refer to each model PDB for applicable models. With case model : PQDSB(1), PQDSBC / Without case model : PQDSA(1)

PQDSA(1), PQDSB(1)

PQDSBC

PQDSBNGCM1

INPUT AC 220V(PQDSB) AC 24V(PQDSB1)

AC 220V(PQDSB) AC 24V(PQDSB1)

- To apply power source through PCB

-To apply power source directly to external source

- In case Non Voltage signal

-In case Voltage signal

- For no power contact point signal input

- For power contact point signal input

- Indoor unit monitoring

Combination

Combination
& Accessory
Control Module

(Contact point linked with outer part)

Dry contact

Key Switch

Lighting Sensor

Fire Alarm

Timer

Motion Door Chek Sensor Detect Sensor

System Structure

170

171

Dry Contact
Connection between an indoor unit and external devices to control various functions.

ODU Dry Contact


Dry contact for demand control.

PQDSBCGCD0

PQDSBCDVM0

Features
1) Model name : PQDSBCGCD0 LG does not 2) Specification Room Control supply this section Unit (Field supply) Dimensions(mm) : 105x78x35 Applied Model : MULTI V Plus II & MULTI V III  Function Field Supply Power - Contact Point : 2 contact point Error Display AC or DC (operation depends on the Control Mode_SW setting) (Depends on Error display power type) - Pl 485 Communication Mode Input : LGAP 485 Communication Power Operation Display AC or DC - Voltage/Non Voltage Input (Depends on Operation display power type) - Error Monitoring Output - Operation Monitoring Output 3) Description The product is especially designed for interface with other controllers using dry contact communication or RS485 communication
COMM Input A Input B
BUS A BUS B

Features
1) Model name : PQDSBCDVM0 2) Specification Applied Model : MULTI V III Error  Function : display - Demand control (3 contact signal) - Demand control (Co-work with DDC) - ODU fan low speed control (Night low noise operation) Low noise - All Off - Error Output (Display) 3) Description or By DDC By Dry The product is especially designed for demand control.
0~10V contact
Demand control (input)

Combination
RS485 Communication Function
RCU : Room Control Unit

Combination

Room Control master

RS485 (RCU)

<RS485 communication Function>


Controller

Simple Contact

Indoor unit

Dry contact

2 Contact Key Fire Alarm

Analogue Input (0~10V)


<PQDSBC Function>

RS485

& Accessory

Max. 16

172

173

Variable Water Flow Control Kit


Accessory developed for controlling the water flow.

Independent Power Module


EEV full close function in case of power cut.

PRVCO

PRIP0

Features
1) Model name : PRVC0 2) Specification Applied Model : Multi V Water  Function - Water pump valve control (0~10V) - Minimum voltage setting available - Operation, error output (display)  Advantage - Water flow consumption reduction - Pump electricity consumption reduction 3) Description The product is specially designed to control the water pump valve in Multi V Water system.

Features
1) Model name : PRIP0 2) Specification Applied Model : Multi V Indoor  Function - Supply Voltage : DV12V 5% - Indoor EEV full close at power cut-off 3) Description The product is specially designed to close the Indoor EEV at power cut-off.

Combination
Cooling Tower

Flow control valve : Regulates the flow or pressure of a fluid, normally responding to signals generated by independent devices. Flow Meter : Measures mass flow rate of a fluid traveling through a tube. (The mass flow rate is the mass of the fluid traveling past a fixed point per unit time.) Pressure Sensor : Measures the pressure.

Cooling Tower

Combination
Single Line Water Flow Line

3 phase 400V
Outdoor Unit

Flow control valve

Pump/Cooling Tower Controller Flow meter

1 phase 220V

4th

Independent Power Module (Option)

Switch BOX

Flow control valve

3rd
Pressure sensor Flow meter
Main Switch

Power Plug 2nd A/C Switch 1st Each room

& Accessory

From Water Source

Independent Power Module (Option)

Switch BOX
Inverter pump

3rd
Main Switch

Power Plug 2nd A/C Switch 1st Each room

174

175

CO2 Sensor
CO2 sensor in ventilation system.

Remote Temperature Sensor


Sensor for detecting the room temperature.

PES-C0RV0

PQRSTA0

Features
1) Model name : PES-C0RV0 2) Specification Applied Model : Eco V, Eco V DX  Function - Supply Voltage : DV12V 5% - Output : 0~5V (Linear output, 1~2,000 ppm CO2) - Accuracy : 30 ppm 5% of reading 3) Description The product is especially designed to detect CO2 concentration in Eco V system.

Features
It can help to detect the exact room temperature. Applied to ceiling cassette, ceiling concealed duct, AWHP and Hydro Kit.

Parts Included
Remote temperature sensor Extension cable (15m) Manual

Combination

Wiring Diagram
1.  Wire to the control box in the indoor unit by removing the existing thermistor and connect the extension cable its place.
Windows Windows Windows Windows

Connector Extension cable

CO2 (ppm)

Closed

Open

Closed

Open

2.  Cut the extension cable to the appropriate length and connect the screw terminal of the remote sensor.
Screw terminal connection

2500

Indoor unit

OFF
Standard Wired Remote Controller

& Accessory

CO2 Sensor

1000

ON

Time (min)

Remote Temperature Sensor

176

177

Cool / Heat Selector


Cooling, heating, or fan mode can be selected to prevent cooling and heating mixing errors during seasonal changes.

PRDSBM

Features
Indoor unit control without central controller Select operation mode : Cooling, Heating, Fan mode  Mode lock for cooling & heating mixing error-proof during the change of season.
Fan or Off Cooling Mode Change Heating

Models Applied
MULTI V PLUS MULTI V WATER II Heat Pump MULTI V MINI MULTI V III Heat Pump MULTI V SPACE II

Wiring Diagram
Push Button Insert wire method

 Connect terminals (, , GND) on the back side of the outdoor dry contact to terminals (, , GND) of outdoor as show below.

& Accessory

Push arrow direction <Outdoor Main PCB>

Insert wire to connector Shows field wiring Connected wiring <Outdoor Dry Contact Back Side>

*C  ommunication line length can be maximum 300m, use communication line as thick as 1.25mm.

Specific set up method is referred to outdoor installation manual or PDB

178

179

AHU Kits
Solution to connect LG outdoor Unit on the DX coil of an air handing unit, with LG's high efficient products for maximum cost saving

Selection of Evaporator
For SCAC
 When selecting evaporator, change Option PCB in Control kit according to below table (Basic Option PCB is for 24k Btu/h )

Detail
Detail

(Main PCB)

Capacity setting 'Option PCB'

Capacity (Btu/h)
PUCKA0 PRCKA0 PRDCA0 PRLK048A0 PRLK096A0 PRCKD21E PRCKD41E PATX13A0E PATX20A0E PATX25A0E PATX35A0E PATX50A0E 18K 24K 30K 36K 42K

Allowed heat exchanger capacity (kW)


5~6 6~7 7~9 9~11 11~13 13~16 20~24

Air flow rate (CMM)


18~21 20~23 22~26 25~32 31~35 33~45 42~55

Specification
Type Model
PUCKA0 Comm.Kit PRCKA0 PRDCA0

48K 60K

* Saturated Suction Temperature (SST) = 6c, SH (Superheat)=5k, Air Temperature = 27c DB / 19c WB

Control
For Single CAC - Self sufficient For Multi V - Self sufficient For Multi V - Controlled by DDC

Comments
No EEV or Expansion Kit need EEV Kits or Expansion Kit EEV Kits or Expansion Kit

W
280 280 330

Dimensions(mm) H D
135 135 180 280 280 430

For MULTI V
When selecting evaporator, change Option PCB in Control kit according to below table (Basic Option PCB' is for 36k Btu/h) After checking the need capacity, remove the 192k Option PCB equipped in the main PCB, and set up the Option PCB fitted the need capacity in the main PCB

Type
Control.Kit

Model
PRCKD21E PRCKD41E

Control
For Multi V - Total AHU control For Multi V - Total AHU control

Max Capacity
1~4 ODU 5~8 ODU

W
600 600

Dimensions(mm) H D
750 750 285 285

Detail

Type

Model
PRLK048A0

Control
For Multi V - In combination with AC system or stand alone(with 1xODU) For Multi V - In combination with AC system or stand alone(with 1xODU)

Max Capacity
28.1kW 56.2kW

Dimensions(mm) W H D
404 404 83 83 217 217

Capacity setting 'Option PCB'

(Main PCB)

EEV Kit PRLK096A0

Model

Option PCB P/No


EBR52358907 EBR52358908 EBR52358909 EBR52358910 EBR52358911 EBR52358912 EBR52358914 EBR52358915

Capacity (Btu/h)
28k 36k 42k 48k 76k 96k 115k 134k 155k 172k 192k

Maximum heat exchanger capacity(kW)


8.6 11.0 13.8 15.4 22.2 28.1 33.7 39.3 45.4 50.4 56.2

Air flow rate (CMM)


22~26 25~32

& Accessory

PRLK048A0

31~35 33~45 50~64 64~72 72~88 88~103 103~116 114~129 121~137

Type

Model
PATX13A0E PATX20A0E

Control
For Multi V - Stand alone(with 1xODU) For Multi V - Stand alone(with 1xODU) For Multi V - Stand alone(with 1xODU) For Multi V - Stand alone(with 1xODU) For Multi V - Stand alone(with 1xODU)

Max Capacity
ODU Capacity : 8~16HP(23~46kW) ODU Capacity : 18~26HP(52~75kW) ODU Capacity : 28~36HP(82~104kW) ODU Capacity : 38~46HP(110~133kW) ODU Capacity : 48~56HP(139~163kW)

Dimensions(mm) W H D

Expansion Kit

PATX25A0E PATX35A0E PATX50A0E

238

169

491

PRLK096A0

EBR52358916 EBR52358917 EBR52358913

291

192

561

Evaporator saturated temperature = 6C, SH(Superheat) = 5K, Air Temperature = 27C DB / 19C WB.

180

181

AHU Kits
Combination
SCAC Application
Refrigerant Piping Communication Wire Sensor Signal *DDC : Digital Direct Controller PUCKA0 Dry contact *DDC PQDSBC
PRCKA0

Multi V Application (Stand alone)


Refrigerant Piping Communication Wire Sensor Signal *DDC : Digital Direct Controller 0-10V *DDC PRDCA0 or Dry contact *DDC PQDSBNGCM1

Air in (from outside)

Air (from outside)

Supply air (to room)

Air in (from outside)

Air (from outside)

Supply air (to room) or Expansion Kit EEV

Multi V Application (in combination with AC system)


Refrigerant Piping Communication Wire Sensor Signal *DDC : Digital Direct Controller PQDSBNGCM1

Multi V Application (Total AHU control for medium to large capacity)


PRCKA0 Dry contact

Temp. Senor / RA, SA(essential), Mix(optional) *DDC Temp. & Humid. Sensor/ RA, SA, OA(optional) Damper Actuator / EA, OA, Mix(optional) Air Handling Unit Expansion Kit

Refrigerant Piping Communication Wire Thermistor (Pipe Temp.) Signal (On / Off) Signal (DC0 ~ 10V)

Air in (from outside)

Air (from outside)

EEV Supply air (to room)

Differential Pressure switch (optional) Valve for Humidifier (optional) CO2 Senor (optional) Control kit Smoke Detector (optional) Fan/ Supply, Return

& Accessory

Wired Remote Controller

Local

Control Kit

182

183

Suction Grille / Canvas


High flexibility for a wide variety of applications.

Parts Included
For the suction grille : For the suction canvas :
Air suction canvas (1EA) Screws for air suction canvas (4EA) Adjusting chain (4EA) Screws for adjusting chain (8EA) Installation manual (1EA) Suction panel with air filter (1EA) Suction panel fix bolt M5x18 (4EA) Installation manual (1EA)

PBSGB30 PBSGB40 PBSC30 PBSC40

Dimensions

Features
High external static pressure facilitates unit use with flexible ducts of varying lengths. When using suction panel, unit requires only 270mm of ceiling space. Blends unobtrusively with any interior decoration.
Model
PBSGB30 PBSGB40

A B B

A B
(Unit : mm)

(Unit : mm)

A
910 1188

B
359 359

C
56 56

Model
PBSC30 PBSC40

A
821 1100

B
274 274

C
42-250 42-250

Models Applied
Ceiling concealed duct _ Built-in type (refer PDB for applicable model)

Application Accessory Model Name


7K

9K

18K

24 K

Grille Canvas

pbsgb30 pbsgb40 pbsc30 pbsc40

over 520mm

Category

Model

Capacity (Btu/h) 12K 15K

over 270mm

& Accessory

184

185

Auto Elevation Grille


Easy filter cleaning with the elevation grille.

Plasma Kit
Air purifying filter to repel dust and allergens.

PTEGM0

PTPKM0 PTPKQ0

Features
Easy filter cleaning with elevation grill - Installation inside main body - Auto horizontal control - 4 points support structure
4-Point Support Structure Auto Horizontal Control

Features
- Memory for users level - Max 4.5m length - Model : PTEGM0(TM, TN, TP)
Memory for users level Auto bottom detection

 It can remove microscopic contaminants such as dust and pollen to help reduce allergies.

Models Applied
STOP

4-way cassette : Single CAC, MULTI, MULTI V (refer PDB for applicable models)

* Operating with wired remote controller PQRCVSL0(QW) and wireless remote controller included in PTEGM0.

Models Applied
4-way cassette : Single CAC, MULTI, Multi V (refer PDB for applicable models)

Parts Supplied
Plasma Kit (1EA) Screws Installation Manual (1EA)

Parts Supplied
Inlet Grille (1EA) Auto elevation grille kit (1EA) Wireless Remote Controller (1EA) Screws (4EA) Installation manual (1EA)

Application

& Accessory

Auto elevation grille kit

Install the kit inside indoor unit

Install the front panel and the Inlet grille

Operate the auto elevation grille by the wireless remote controller

Easy maintenance

186

187

Ventilation Kit
Fresh air can be supplied from outside through this ventilation kit.

Cassette Cover
Air purifying filter to prevent dust and allergens.

PTVK410 PTVK420 PTVK430

PTDCM PTDCQ

PTVK410

PTVK420

PTVK430

Features
PTVK410 : 1 Ventilation Kit, 8 Bolts, 1 Insulation PTVK420 : 1 Flange, 7 Screws PTVK420 : 1 Flange, 4 Screws, 1 Insulation

Features
Specially designed for indoor unit. Covers the side area of cassette. Gives elegant looks. Light weight. Suitable when false ceiling is unavailable.

Models Applied
 There are 2 solutions for Fresh air - PTVK410+PTVK420 (for chassis TP, TN, TM) - PTVK430 (for chassis TR, TQ, TP, TN, TM) * Users can purchase and use PTVK430 in addition to PTVK410+PTVK420 in need to phase in larger outdoor air volume.

Models Applied
4-way cassette (TP, TN, TM, TQ, TR)

Parts Supplied Dimensions


406

Assembly Diagram

Cover A (4EA), Cover B (4EA) Cover C (4EA), Cover D (4EA) Screws Installation Manual (1EA)

13
443

Accessory Model Name


840 435

81
419 840 55mm

Model
PTDCM
PT-UMC/ PT-UMC1

Front Panel
TP/TN TN TR

Weight(kg) NET Gross


5.9 5.9 5.0 5.0 8.8 8.8 7.2 7.2

W
1,157 1,157 907 907

Dimensions(mm) H
1,157 1,157 907 907

D
268 310 268 310

& Accessory

PTDCQ

PT-UQC TQ

PTVK410+PTVK420

PTVK430

188

189

Air Guide
Air discharge in difficult to access areas.

Application

PRAGX*SO

Features
Converts vertical discharge into horizontal discharge. Designed for outdoor discharge air. Direction of air discharge can be changed by simple installation. Installation flexibility

564

33

Models Applied
MULTI V III (UX2, UX3) * In case of UX3, must purchase 2 units of PRAGX3SO
632 618

512

512

R6

00

Multi V III (UX2)


50 45 652

Multi V III (UX3)

564
564

60

33

652

512

512

R6

00

50 512

Dimensions
Model
PRAGX2S0 PRAGX3S0

33

Gross Weight
22.5kg 17kg

Net Weight
12.3kg 9.4kg

Multi V III (UX3)


50 45 632 652

570

512

R6

00

50 45

652

632

618

564 564 618

3333
60 0

60
900

652

512 512

512 512

00 00 R6 R6

500

652

5050 45 45 50 632 632

652 652 570


50 45 832

50

500

R6

00

& Accessory

570 618 618

760

0 0 60 60

Multi V III (UX2)


652 652
900

832 900
718

500

500

570 570

500

762

R6

00

50

45

832
832

500

50 50

R6

00

760

50

45

900 900

832

832

500 500

718

50 50

45 45

832 832

760 760

762

190

500 500

00 00 R6 R6

45

760

904

718

191

Refrigerant Charging Kit


Recharge refrigerant after a pump down or when refrigerant is either insufficient or excessive.

Drain Pan

PRAC1

PRODX20 PRODX30

Procedure
Arrange manifold, capillary assembly, refrigerant vessel and scale Connect manifold to the gas pipe service valve of outdoor uint as shown in the figure. Connect manifold and capillary tube. Use designated capillary assembly only. If designated capillary assembly isnt used, the system may get damaged. Connect capillary and refrigerant vessel. Purge hose and manifold. After 568 is displayed, open the valve and charge the refrigerant

Features
This unit can be applied for outdoor units drain.

Installation Models Applied


Mainfold Capillary Assembly Tuck drain pan below base pan

Dimensions
202 133

Service Valve

* Fault Detect & Diagnosis

Drain Pipe
In case of the installation of drain pan, drain pipe should be located below the SVC valve.
69

Refrigerant

Push drain pan in the direction of the arrow. Brackets can be fixed on the side panel

This unit does not cover water drops of the outside product. Connect drain hose to drain pipe for drain condensate.

Error Contents about Auto Refrigerant Charging Function


329 : Temperature Range Error (In case that indoor unit or outdoor unit is out of range) 339 : Low Pressure Descent Error (In case the system runs at low pressure limit for over 10 minutes) 349 : Rapid refrigerant inflow (In case the liquid refrigerant flows in because of not using designated capil-lary assembly) 359 : Instability Error (In case the high/low pressure target doesnt get satisfied for some time after the starting operation)

Accessory Model Name


Model
PRODX20 PRODX30

& Accessory

L
920mm 1240mm

Remark
UX2 UX3

192

193

Stopper Valves
Under 1/2 (inch)

Details of Model Name


case1
pipe 1 & 2 : need to install indoor indoor unit, outlet side connector should (Room 3 & 4 : in usethe / Room units) be cut according to installation pipe. Cut inlet side of the connector, and weld In case of the installation of additional

PRVT120
Under 7/8 (inch)

Stopper Valve is already installed

"A"
9.52 : 19.05 3.0m 9.52 : 19.05 3.0m

PRVT780
Under 9/8 (inch)

Room 1 Closed state Pin(Closed) Stopper valves


Pin(Open)

PRVT980 Features
Model Spec

9.52 : 15.88 In case of installation of stopper valve, In case of installation of additional are part should be facing towards 10.0m indoor unit, SVC valve should be in additional indoor unit. closed state

Room 2

-When welding, service valve shoud be wrapped by wet cloth.

9.52 : 15.88

PRVT120
6.35 : 12.7 3.0m

5.0m

Room 3

Room 4

PRVT780

In case of installation of additional indoor unit, refrigerant of used indoor unit must be discharged.(Room3 & Room4) If stopper valve is already installed, you can install additional indoor unit without refrigerant loss from the entire system. After installation of additional indoor unit, you just need refrigerant charging A section. In for case of the installation of additional Cut inlet side of the connector, and weld Then, open the Stopper Valve. the pipe indoor unit, outlet side connector should
PRVT980
be cut according to installation pipe.

Open/close port

Charge port

9.52 : 19.05 3.0m

Usage
This unit can be applied for the additional indoor units installation. This unit can be applied for each indoor units service

9.52 : 19.05 3.0m 9.52 : 15.88 In case of installation of stopper valve, are part should be facing towards additional indoor unit. 10.0m
In case of the installation of additional Cut inlet side of the connector, and weld In case of the installation of additional Cut inlet side the connector, and weld theof pipe indoor unit, outlet side connector should the pipe indoor unit, outlet side connector should be cut according to installation pipe. be cut according to installation pipe.

Stopper Valves

Pin(Closed)

Pin(Open) Open state

In case of installation of additional indoor unit, SVC valve should be in closed state 6.35 : 12.7
3.0m

Installation

-When welding, service valve shoud be wrapped by wet cloth.


9.52 : 15.88 3.0m

Room 1

& Accessory

Room 2

Pin(Closed)

Pin(Closed)

Pin(Open)

Pin(Open)

In case ofcase the installation of additional Cut inlet side of side the connector, and weld 1. Cut  the inlet side of connector, the 2. If installing  additional indoor units, the In of the installation of additional Cut inlet of the and weld the pipe indoor unit, outlet side connector should should the pipe and weld the pipe indoor unit,connector outlet side connector connector, outlet side should be cut be cut according to installation pipe. be cut according to installation pipe. according to installation pipe.

In case of installation of stopper In  case of installing installation of additional 3. When installing a stopper valve, valve, 4. W hen anadditional In case of installation of stopper valve, In case of installation of additional are partshould should be facing towards indoor unit, SVC valve shouldvalve be in the flare part be facing indoor the SVC are part should be facing towards indoor unit, SVC valve unit, should be in additional indoor unit. closed state towards additional indoor unit. closed state should be in closed state. additional indoor unit.

Room 3

- When welding, service valve shoud be wrapped by wet cloth.

-When welding, service valve shoud be wrapped by wet cloth. -When welding, service valve shoud be wrapped by wet cloth.

Room 4

194

Pin(Closed) Pin(Closed)

Pin(Open) Pin(Open)

In case In ofcase installation of stopper valve, valve, In case In ofcase installation of additional of installation of stopper of installation of additional are part should be facing SVC valve should be in be in are part should be towards facing towards indoor unit, indoor unit, SVC valve should

195

Heat Recovery Unit


Reducers for Indoor Unit and HR Unit PRHR021 PRHR031 PRHR041
PRHR021 (2 branch Unit) PRHR031 (3 branch Unit) PRHR041 (4 branch Unit)

Gas pipeGas pipe (Unit : mm) Models Models Liquid pipe Liquid pipe pipe Gas pipe Gas Gas pipe High pressure Low pressure High pressure Low pressure Models Gas pipe Models Models Liquid pipe High Gas pipe Gas pipe Liquid pipe Liquid pipe Model Liquid pipe pressure Low pressure Gas pipe Models High pressure Low pressure High pressure Low pressure High pressure Low pressure Liquid pipe Models Models Liquidpipe pipe Liquid Models High pressure Low pressure pipe Highpressure pressure Lowpressure pressure High Low Indoor unit Indoor Liquid unit High pressure Low pressure OD9.52 6.35 OD9.52 6.35 reducer unit reducer unit Indoor Indoor unit Indoor OD15.88 12.7 OD15.88 12.7 Indoor unit reducer Indoor unit OD9.52 6.35 OD9.52 6.35 Indoor unit Indoor unit 6.35 reducer reducer OD9.52 reducer Indoor unit OD15.88 12.7 OD15.88 12.7 OD15.88 12.7 OD9.52 6.35 reducer OD9.52 6.35 OD9.52 6.35 reducer reducer OD15.88 12.7 OD15.88 12.7 OD15.88 12.7 OD9.52 6.35 reducer OD15.88 12.7
PRHR020 PRHR020
OD19.05 OD19.05 15.88 15.88 12.7 12.7 OD22.2 19.05 OD22.2 19.05 15.88 15.88 15.88 15.88 12.7 12.7 12.7

PRHR021

PRHR020 PRHR020 PRHR020 PRHR020

Features
Max. 32 indoor units can be connected. (Max 8 indoor units per branch) Due to the automatic search algorithm for piping detection, easy installation Subcooling cycle in HR unit makes the system efficiency maximum.

HR unit reducer

HR unit HRunit unit HR reducer HR unit reducer reducer reducer


PRHR031/ PRHR041

HR unit reducer HR unit reducer

OD19.05 15.88 15.88 12.7 15.88 OD19.05 12.7 OD9.52 6.35 OD22.2 19.05 OD22.2 15.88 19.05 OD9.52 6.35OD19.05 OD22.2 19.0512.7 15.88 PRHR020 PRHR020 OD19.05 15.8815.88 12.7 OD22.2 19.05 OD19.05 15.88 15.88 12.7 12.7 OD19.05 OD22.2 19.05 19.05 15.88 OD22.2 PRHR020 OD9.52 6.35 OD9.52 6.35 OD19.05 OD9.52 6.35 15.88 12.7 OD22.2 19.05 15.88 OD9.52 6.35 OD9.52 6.35 OD9.52 6.35 OD12.7 9.52 OD12.7 9.52 OD9.52 6.35 OD15.88 OD15.88 12.7

HR unit reducer HR unit HR unit reducer reducer

OD12.7 OD12.7 9.52 OD12.7 9.52 OD12.7 9.52 OD12.7 9.52

OD12.7 9.52 9.52 OD15.88 12.7 OD15.88 OD12.7 9.52 OD15.88 12.7 12.7 OD15.88 OD15.88 12.7

OD15.88 12.7 OD15.88

PRHR030 PRHR030 PRHR030 / / /PRHR030 PRHR040 / PRHR040 PRHR040 PRHR040

PRHR030 PRHR030 12.7 9.52 OD22.2 19.05 15.88 OD15.88 12.7OD15.88 9.52 OD22.2 19.05 15.88 / / OD28.58 PRHR030 PRHR030 PRHR040 PRHR040 OD15.88 12.7 9.52 OD15.88 12.7 OD22.2 9.52 19.05 OD22.2 19.05 OD22.2 15.88 19.05 15.88 PRHR030 15.88 / 9.52 /OD15.88 12.7 OD28.58 22.2 OD28.58 19.05 OD15.88 12.7 9.52 OD22.2 19.05 15.88 / OD15.88 12.7 PRHR040 9.52 OD22.2 19.05 15.88 OD15.88 12.7 9.52 OD22.2 19.05 15.88 PRHR040 OD28.58 22.2 22.2 19.05 19.05 OD28.58 OD15.88 12.7 9.52 OD22.2 19.05 15.88 PRHR040 OD28.58 22.2 19.05
OD15.88 12.7 OD15.88 12.7 OD15.88 12.7 OD15.88 12.7 12.7 OD15.88 OD15.88 12.7

OD28.58 22.2 22.2 19.05 22.2OD28.58 19.05 22.2 OD28.58 22.2

19.05 19.05 19.05

Models Applied
MULTI V SYNC MULTI V SYNC II MULTI V WATER II Heat Recovery MULTI V III Heat Recovery

OD19.05

OD19.05 15.88 OD19.05 15.88 OD19.05

15.88 15.88 15.88

OD19.05 12.7 15.88 OD19.05 OD15.88 12.7 OD15.88 OD19.05 12.7 15.88 OD19.05 15.88 OD15.88 OD19.05 15.88

Convenient Free Zoning


MULTI V III Heat recovery provides flexible control over individual zones for the users convenience

Specification
Category
Number of branch Max. connectable capacity of indoor units (Per branch/unit) Max. number of connectable indoor units per branch Cooling Nominal Input Heating Net. Weight Dimensions(WxHxD) Liquid Indoor Unit Gas Piping Liquid connections Outdoor Unit Low pressure High Pressure Power Supply EA kW EA kW kW kg mm mm(inch) mm(inch) mm(inch) mm(inch) mm(inch) /V/Hz

PRHR021
2 16/32 8 0.026 0.026 18 801x218x617 9.52(3/8) 15.88(5/8) 9.52(3/8) 22.2(7/8) 19.05(3/4) 1 / 220~240 / 50

PRHR031
3 16/48 8 0.040 0.040 20 801x218x617 9.52(3/8) 15.88(5/8) 15.88(5/8) 28.58(11/8) 22.2(7/8) 1 / 220~240 / 50

PRHR041
4 16/58 8 0.040 0.040 22 801x218x617 9.52(3/8) 15.88(5/8) 15.88(5/8) 28.58(11/8) 22.2(7/8) 1 / 220~240 / 50

Individual Control - Perfect individual control over spaces ventilation needed Zone Control - Max. of 8 indoor units can be connected for one branch - Max. of 32 indoor units can be connected for one HR unit -Same opeational model can be operated by indoor units with zone control function installed Combination of Individual and Zoning Installations - Flexible piping design Save Product and Installation Cost
IT Room

Ofce

Kitchen

Room

[Zoning control]

& Accessory

Dimensions
HR unit (1EA) Hanging bolts M10 or M8 (4EA) Nut M8 or M10 (8EA) Washers M10 (8EA) Reducers

HR unit

Zoning Control (Max Indoor unit 8EA)

196

197

Y Branch and Header Branch ( )


For refrigerant distribution of indoor units.

Accessory Model Name


Header Branch
R410A Model Gas pipe Liquid pipe

(Unit : mm)

4 branch / ARBL054
Y Branch Header Branch

7 branch / ARBL057

4 branch / ARBL104

Features
Various Y-branch pipe of different capacities make MULTI V installation much easier. Y-branch and header branch for both gas and liquid are provided. Insulation material is also provided for covering the branches.
7 branch / ARBL107

10 branch / ARBL1010

Piping Diagram

10 branch / ARBL2010

Y- branch

Header Branch

Outdoor unit

Models Applied
MULTI V PLUS MULTI V PLUS II MULTI V III Heat Pump MULTI V SPACE MULTI V SYNC II MULTI V III Heat Recovery MULTI V SYNC MULTI V SPACE II MULTI V MINI MULTI V WATER II

& Accessory

198

199

Piping Accessories
R410A / MULTI V PLUS, MULTI V PLUS II
(Unit : mm)

R410A / MULTI V SYNC, MULTI V SPACE II


(Unit : mm)

2 Outdoor Units Model Low Pressure Gas pipe Liquid pipe Model

3 Outdoor Units Low Pressure Gas pipe Liquid pipe Model

2 Outdoor Units Low Pressure Gas pipe Liquid pipe High Pressure Gas pipe Model

2 Outdoor Units Low Pressure Gas pipe Liquid pipe High Pressure Gas pipe

ARCNN20

ARCNB20

ARCNN20

ARCNB21

ARCNN30

ARCNB30

R410A / MULTI V III Heat Pump


(Unit : mm)

R410A / MULTI V III Heat Recovery


(Unit : mm)

2 Outdoor Units
I.D.28.58

3 Outdoor Units
416 408 I.D.28.58 416 408 I.D.28.58 I.D.28.58 I.D.15.88

331 314 I.D.15.88

331 314 I.D.15.88

2 Outdoor Units
I.D.15.88 83

3 Outdoor Units High Pressure Gas pipe Model Low Pressure Gas pipe Liquid pipe High Pressure Gas pipe

Model

Low Pressure Gas pipe


416 408 I.D.28.58 416 408 I.D.28.58 I.D.28.58 331 314 I.D.28.58 I.D.15.88

Liquid pipe
C C

C C Low Pressure Model ARCNN21 ARCNN21Gas pipe


I.D.31.8 I.D.34.9 I.D.31.8 I.D.34.9 I.D.22.2 130 130 341 298

111I.D.22.2

I.D.19.05 111

I.D.19.05

Liquid pipe
70

I.D.12.7 I.D.9.52 I.D.12.7 83 I.D.9.52

Model

I.D.41.3 I.D.38.1 I.D.41.3 O.D.34.9I.D.38.1 O.D.34.9 I.D.28.58

I.D.28.58

I.D.22.2 O.D.19.05 I.D.22.2 O.D.19.05 I.D.12.7 I.D.15.88 I.D.12.7

Low Pressure Gas pipe

Liquid pipe

I.D.15.88

70

331 314 I.D.15.88 I.D.15.88 I.D.15.88

341 298

334 281

334 281
I.D.28.58

C C ARCNN21 ARCNN21 ARCNN21


C C

I.D.31.8 I.D.34.9

I.D.22.2 I.D.31.8 I.D.34.9

111

I.D.22.2

I.D.19.05 111

I.D.19.05I.D.12.7 I.D.9.52

I.D.12.7 I.D.9.52 83

83

B B ARCNN31 ARCNN31 ARCNN31


B CB C

416 408

I.D.28.58 111

I.D.15.88 I.D.19.05

331 314

334 281
I.D.15.88 I.D.12.7 I.D.9.52 83

341 298

334 281

I.D.28.58
I.D.22. 2 I.D.19.05 I.D.19.05 83

416 408

I.D.28.58 111

I.D.41.3

I.D.41.3 I.D.41.3

I.D.34.9 O.D.34.9 I.D.28.58

I.D.34.9 111

111 I.D.22.2

I.D.19.05 I.D.22.2

I.D.19.05

I.D.19.05

83 I.D.19.05

83

ARCNB21

I.D.31.8 I.D.34.9 I.D.41.3I .D.38.1 O.D.34.9

I.D.22. 2

I.D.22. 2

I.D.19.05

I.D.19.05

83

ARCNB31

I.D.41.3 I.D.41.3 O.D.34.9

I.D.34.9

111

I.D.31.8 I.D.34.9
I.D.15.88 I.D.12.7

I.D.22. 2

I.D.41.3 I.D.38.1 O.D.34.9 I.D.41.3 I.D.38.1 O.D.34.9 I.D.28.58


416 408 130 416 408 130 I.D.28.58 I.D.28.58

I.D.22.2 O.D.19.05 I.D.28.58


331 314

I.D.22.2 O.D.19.05 I.D.12.7 I.D.15.88


331 314

I.D.12.7

I.D.15.88

O.D.34.9 I.D.41.3

I.D.28.58

I.D.22. 2 O.D.19.05

I.D.41.3I .D.38.1 O.D.34.9

I.D.12.7

I.D.15.88

I.D.28.58

I.D.15.88 I.D.12.7I.D.15.88 I.D.12.7

I.D.15.88 I.D.12.7
125

I.D.28.58

I.D.28.58

I.D.28.58

I.D.28.58

70 I.D.15.88

70 I.D.15.88 I.D.15.88

130

I.D.15.88

125 415 375

125 415 375 334 281 334 281

70

130

C C ARCNN21ARCNN21 B B ARCNN31 ARCNN31


C

341

341
111 I.D.22.2 I.D.19.05 111 I.D.12.7 I.D.9.52 334 I.D.19.05 334 281 281 I.D.12.7 I.D.9.52 83 83

I.D.31.8 I.D.34.9

298 298 I.D.22.2 I.D.31.8 I.D.34.9

I.D.22.2 O.D.19.05 I.D.41.3 I.D.38.1 O.D.34.9 I.D.41.3 I.D.38.1 O.D.34.9 I.D.28.58 I.D.28.58 I.D.41.3 I.D.41.3 I.D.34.9 111 111 I.D.34.9 I.D.22.2 I.D.19.05 I.D.22.2

I.D.22.2 O.D.19.05 I.D.12.7 I.D.15.88

I.D.12.7

I.D.15.88

I.D.19.05 I.D.19.05
70

83 I.D.19.05

83

A A ARCNN41 ARCNN41
BA CB C

I.D.41.3 I.D.44.48 I.D.53.98 I.D.44.48 I.D.53.98

134 I.D.41.3

I.D.22.2 134

I.D.19.05 I.D.22.2

I.D.19.05 I.D.19.05

83 I.D.19.05

83

I.D.25.4 O.D.22.2 I.D.25.4 O.D.22.2 I.D.15.88 I.D.12.7I.D.15.88 I.D.12.7 I.D.28.58 I.D.28.58 80 80

I.D.41.3 130 O.D.34.9 I.D.41.3


341

4 Outdoor Units
I.D.28.58 341
298 125

O.D.34.9 130

70

I.D.28.58

I.D.15.88 I.D.12.7
334 281 334 281

I.D.15.88 I.D.12.7

4 Outdoor Units Model Low Pressure Gas pipe Liquid pipe High Pressure Gas pipe

298 125

B B Low Pressure ModelARCNN31ARCNN31 A Gas pipe A


415 415 375
I.D.41.3

334
111 I.D.34.9

375 I.D.41.3

I.D.34.9

281
111 I.D.22.2 I.D.19.05 I.D.22.2

Liquid pipe
281
I.D.19.05 I.D.19.05 83

334

I.D.19.05

83

I.D.41.3

O.D.34.9

I.D.41.3

O.D.34.9

ARCNN41 ARCNN41

I.D.44.48 I.D.53.98

134 I.D.41.3 I.D.44.48 I.D.53.98 I.D.28.58


125 415 375 125

I.D.22.2 134 I.D.41.3 I.D.28.58

I.D.19.05

I.D.22.2

I.D.19.05 I.D.19.05

83 I.D.19.05

83

I.D.25.4 O.D.22.2

I.D.25.4 I.D.15.88 O.D.22.2I.D.12.7 I.D.15.88 I.D.12.7

I.D.15.88 I.D.12.7

I.D.15.88 I.D.12.7

I.D.28.58 415
375

I.D.28.58

80

334 281

80

334 281

A C

A A ARCNN41ARCNN41 ARCNN41
C

415 375
83 I.D.19.05 83

334 281

341 298

I.D.44.48 I.D.53.98

I.D.41.3 I.D.44.48 I.D.53.98

134

I.D.41.3

I.D.22.2 134

I.D.19.05

I.D.22.2

I.D.19.05 I.D.19.05 I.D.25.4 O.D.22.2

I.D.25.4 O.D.22.2

ARCNB41

I.D.44.48 I.D.53.98

I.D.41.3

134

I.D.22. 2 I.D.19.05 I.D.25.4 O.D.22.2

I.D.19.05

83

I.D.41.3 I.D.41.3 O.D.34.9

I.D.34.9

111

I.D.15.88 I.D.12.7 I.D.28.58 I.D.28.58 80 80

I.D.15.88 I.D.12.7

I.D.15.88 I.D.12.7

I.D.28.58

80

I.D.28.58 125

& Accessory

200

201

Piping Accessories
R410A / MULTI V PLUS, MULTI V SPACE, MULTI V MINI
MULTI V PLUS II, MULTI V SPACE II MULTI V III Heat Pump, MULTI V WATER II Heat Pump
(Unit : mm)

R410A / MULTI V PLUS, MULTI V PLUS II


MULTI V III Heat Pump, MULTI V WATER II Heat Pump
(Unit : mm)

R410A / MULTI V SYNC, MULTI V SYNC II, MULTI V III Heat Pump
MULTI V WATER II Heat Pump
(Unit : mm)

Model

Gas pipe

Liquid pipe

Model

Gas pipe
I.D19.05 I.D28.58 I.D22.2 I.D15.88 I.D12.7

Liquid pipe
I.D19.05 I.D15.88 I.D15.88 I.D12.7

Model

Low Pressure Gas pipe

Liquid pipe

High Pressure Gas pipe

I.D12.7

I.D15.88

I.D15.88

I.D9.52

I.D9.52

I.D6.35 I.D12.7

ARBLN01621
I.D15.88 I.D19.05 O.D15.88 I.D12.7 I.D15.88

I.D6.35

ARBLN07121
I.D. 9.52 I.D6.35 I.D34.9

I.D12.7 I.D19.05

I.D12.7

I.D15.88

I.D9.52

I.D31.8 I.D19.05 O.D22.2 I.D28.58 O.D31.8 O.D19.05 I.D28.58 I.D15.88

I.D15.88 O.D12.7 I.D6.35 I.D9.52 O.D12.7

I.D19.05

I.D12.7

I.D31.8

O.D9.52

I.D9.52 I.D22.2

ARBLB01621

I.D15.88

ARBLB01620 ARBLB01620
I.D19.05 O.D15.88 I.D12.7 I.D15.88

I.D. 19.05 I.D. 19.05 I.D. 15.88 I.D. 15.88


I.D6.35

I.D. 15.88 I.D. 15.88 12.7 9.52 I.D. I.D. 12.7 I.D. I.D. 12.7 I.D. 12.7 I.D. 9.52
I.D. 15.88

I.D9.52

I.D6.35

I.D. 6.35 I.D. 6.35 I.D. 12.7 I.D. 12.7 I.D. 9.52 I.D. 15.88 I.D. 9.52 I.D. 15.88
I.D. 6.35

I.D. 9.52 I.D. 9.52 I.D. 12.7 I.D. 12.7 I.D. 15.88 I.D. 15.88
I.D. 9.52 I.D. 12.7

I.D. 12.7 I.D. 12.7 I.D. 19.05


I.D. 15.88

I.D. 19.05
I.D. 9.52

I.D. 6.35 I.D. 6.35


I.D. 12.7 I.D. 9.52

I.D. 15.88

I.D. 12.7

I.D12.7 ARBLB01620 I.D. 15.88 O.D9.52

I.D34.9 I.D34.9 I.D41.3 I.D38.1 I.D28.58

ARBLB01620
I.D. 12.7

I.D. 12.7

I.D. I.D. 12.7 12.7 I.D. 9.52 I.D. 15.88 I.D. 12.7 I.D. 6.35 I.D. 15.88 I.D. 6.35
I.D. 15.88 I.D. 12.7

I.D6.35

I.D. 12.7

I.D. 6.35 I.D. 15.88 I.D. 12.7 I.D. 6.35 I.D. 9.52 I.D. 6.35 I.D. 15.88 I.D. 9.52 I.D. 9.52
I.D. 6.35 I.D. 9.52

I.D. 9.52

I.D. 12.7

I.D. 15.88

I.D. 9.52 I.D. 12.7 I.D. 12.7 I.D. 15.88 I.D. 12.7 6.35 I.D. 9.52 I.D. I.D. 9.52 I.D. 6.35

I.D. 12.7 I.D. 9.52 I.D. 6.35

I.D22.2

I.D19.05

I.D15.88

I.D19.05

I.D9.52

I.D9.52

I.D6.35

I.D38.1

I.D28.58

ARBLN03321

ARBLN14521
I.D25.4 I.D28.58 O.D19.05 I.D15.88 I.D19.05 I.D25.4 O.D19.05 I.D12.7 I.D9.52 I.D12.7 I.D6.35 I.D12.7 I.D12.7 I.D12.7

I.D. 15.88
I.D34.9 I.D22.2 O.D34.9

I.D. 12.7

I.D. 6.35 I.D. 9.52 I.D. 15.88 I.D. 6.35 I.D. 15.88 I.D. 6.35 I.D. 19.05 I.D. 19.05 I.D. 9.52 I.D. 9.52
I.D. 6.35 I.D. 12.7 I.D. 9.52 I.D. 15.88 I.D. 19.05

I.D41.3 O.D38.1

I.D41.3

I.D38.1

19.05 I.D. 22.2 I.D.I.D. 19.05 I.D. 22.2


I.D22.2 I.D19.05 I.D15.88 I.D19.05

I.D. 19.05 I.D. 19.05 I.D. 15.88 I.D. 22.2 I.D. 15.88 I.D. 22.2

O.D22.2

I.D15.88

I.D12.7 O.D15.88

O.D28.58

I.D19.05

I.D19.05 O.D19.05 I.D 22.2 I.D 22.2

I.D22.2

ARBLB03320 ARBLB03320

I.D. 22.2 I.D. 15.88 I.D. 15.88

I.D. 19.05

I.D25.4

I.D12.7

ARBLB03321 ARBLN23220
O.D19.05 I.D 22.2

I.D28.58

O.D19.05 I.D15.88 I.D19.05 I.D12.7

ARBLB03320

I.D. 19.05 I.D. 6.35 I.D6.35 I.D. 6.35 I.D. 15.88 I.D. 9.52 I.D. 22.2 I.D. 19.05 I.D. 15.88 I.D. 22.2 ARBLB03320 I.D. 15.88 I.D. 12.7 I.D. 15.88 I.D. 12.7 I.D. 9.52 I.D. 6.35 I.D. 12.7 O.D. 22.2 O.D. 28.58 O.D. 28.58 25.4 O.D. 22.2 I.D. 15.88 I.D. 9.52 I.D. 15.88 I.D. I.D12.7 I.D. 25.4
I.D9.52 I.D9.52 I.D12.7

I.D. 9.52 I.D. 19.05 I.D. 15.88 I.D. 22.2 I.D. 9.52 I.D. 9.52 I.D. 9.52

I.D. 9.52

I.D. 12.7 I.D. 12.7

I.D. 12.7 I.D. 9.52 I.D. 6.35 I.D. 12.7 I.D. 12.7 I.D. 15.88 I.D. 15.88 I.D. 19.05 I.D.12.7 19.05 I.D.
I.D. 15.88 I.D. 19.05

I.D. 6.35 I.D. 19.05 I.D. 6.35 I.D. 9.52 I.D. 6.35 I.D. 9.52 I.D. 9.52
I.D. 6.35 I.D. 9.52

I.D. 15.88

O.D. 22.2 O.D. 28.58 I.D. 25.4


I.D9.52

I.D. 12.7

I.D. 6.35 I.D. 12.7


I.D12.7 I.D6.35

I.D. 15.88
I.D25.4 I.D 22.2 O.D19.05

O.D. 22.2 O.D. 28.58 I.D. 25.4

I.D. 6.35 I.D. 9.52

I.D. 22.2 O.D. 19.05 I.D. 12.7

I.D. 22.2 I.D. 12.7 I.D. 6.35 I.D. 22.2 O.D. 19.05 I.D. 9.52 O.D. 19.05

I.D. 12.7 I.D. 15.88 I.D. 12.7 I.D. 19.05 I.D. 12.7 6.35 I.D. 9.52 I.D. I.D. 9.52 I.D. 6.35

I.D. 9.52 I.D. 6.35

I.D. 22.2 O.D. 19.05

I.D19.05 I.D28.58 I.D22.2

I.D. 28.58 I.D. 28.58 I.D. 28.58 I.D. 22.2 I.D. 22.2 I.D. 22.2
I.D15.88

I.D12.7

I.D15.88

I.D. 22.2 I.D. 22.2 I.D. 25.4 I.D. 22.2 I.D. I.D. 25.4 I.D. 19.05 25.4 I.D19.05 I.D. I.D. 28.58 I.D.19.05 19.05 I.D. 12.7 I.D. 28.58 I.D. 28.58 I.D. 12.7 I.D. 12.7 I.D15.88 I.D12.7

I.D12.7

ARBLB07121

I.D31.8

ARBLB07120 ARBLB07120
I.D19.05 I.D15.88 I.D31.8 O.D22.2 I.D28.58 O.D19.05 I.D22.2 I.D28.58

I.D. 25.4 I.D. 25.4 I.D. 25.4 I.D. 28.58 ARBLB07120 I.D. 22.2
I.D19.05

I.D34.9 O.D31.8

ARBLB07120

I.D. 28.58 I.D. 19.05 19.05 19.05 I.D. 28.58I.D.I.D. I.D. 28.58 I.D. 15.88 I.D. 22.2 I.D. 15.88 I.D12.7 I.D. 15.88 I.D. 25.4 I.D. 19.05 I.D. 28.58 I.D. 22.2 I.D. 22.2 I.D. 22.2 I.D. 12.7 2 X 2 X I.D19.05 I.D15.88 X2 34.928.58 O.D. 28.58 19.05 I.D. 34.9 I.D. O.D. 28.58 I.D6.35 I.D. 15.88 O.D. 22.2 I.D. O.D12.7 I.D. 15.88 O.D.I.D. 22.2 I.D. 34.9 O.D. 28.58 I.D. 25.4 I.D. 15.88 I.D. 15.88 I.D. 19.05 I.D. 31.8 I.D. 31.8 O.D. 22.2 I.D. 19.05 I.D9.52 I.D. 31.8 I.D. 19.05
I.D9.52

I.D. 12.7 I.D. 12.7 I.D. 12.7 I.D. 15.88 I.D. 9.52 I.D. 28.58 I.D. 9.52 9.52 I.D. 15.88 I.D. I.D. 15.88 I.D. 28.58 I.D. 19.05 I.D. 28.58 I.D. I.D. 19.05 19.05 I.D. 6.35 I.D. 6.35 I.D. 6.35 I.D. 12.7 I.D. 22.2 I.D. 22.2 I.D. 22.2 I.D. 9.52 I.D.9.52 9.52 I.D. 15.88 I.D. I.D. 28.58 I.D. I.D.12.7 12.7 I.D. 9.52 I.D. 12.7 I.D. 19.05 I.D. 6.35

I.D. 28.58 I.D. 28.58 I.D. 28.58

I.D. 19.05 I.D. I.D. 19.05 25.4 I.D. 25.4 I.D. 25.4

I.D. 19.05

I.D. 15.88 I.D. I.D. 15.88 19.05 I.D. 15.88 I.D. 25.4 I.D. 19.05 28.58 I.D. 19.05 I.D. I.D.I.D. 19.05 12.7 I.D. 12.7 I.D. 12.7

I.D. 15.88 I.D. 15.88 I.D. 34.9 O.D. 28.58 O.D. I.D. 15.88 22.2 I.D. 31.8 I.D. 19.05 I.D. 9.52 O.D. 12.7 O.D. 19.05 I.D. 12.7 I.D. 15.88
I.D34.9 I.D34.9 I.D41.3 I.D38.1 I.D28.58

O.D. 19.05 I.D. 12.7 O.D. 19.05 I.D. 15.88 12.7 O.D. 19.05 I.D.I.D. 12.7 X 2

O.D12.7

I.D. 22.2

9.52 I.D.I.D. 9.52 O.D. 12.7 I.D. O.D. 9.52 12.7 I.D. 9.52 O.D. I.D. 12.712.7

I.D. 15.88 I.D. 9.52 O.D. 19.05 19.05 I.D. 9.52 I.D.O.D. 22.2 O.D. 19.05 O.D. 19.05 I.D. 9.52 O.D. O.D. 19.05 I.D. 12.7 I.D.19.05 12.7 I.D. 12.7 I.D. 12.7 I.D. 12.7 I.D. 12.7 I.D. 19.05 I.D. 12.7

O.D. 19.05 I.D. 12.7

O.D. 19.05

I.D. 9.52

I.D. 12.7

I.D. 41.3

I.D. 41.3 I.D. 41.3 I.D. 34.9 I.D. 34.9


I.D. 38.1

I.D. 34.9

I.D. 34.9 I.D. 41.3 I.D. 34.9 I.D. 41.3 I.D. 31.8

I.D. 34.9 I.D. 41.3


I.D. 22.2

I.D. 19.05

I.D38.1

I.D28.58

ARBLB14521

I.D34.9 I.D41.3 O.D38.1 I.D41.3 I.D38.1 O.D34.9

I.D22.2

I.D. 38.1 I.D. 38.1 ARBLB14520

ARBLB14520 34.9 ARBLB14520 I.D.I.D. 28.58


O.D28.58 I.D22.2 I.D19.05 O.D15.88

O.D22.2

I.D15.88 I.D19.05

I.D12.7

ARBLB14520

I.D. 19.05 I.D. 19.05 I.D. 15.88 I.D. 28.58 O.D. 34.9 I.D. 41.3 I.D. 28.58 I.D. 34.9 I.D. 15.88 I.D. 15.88 I.D. 19.05 I.D. 34.9 I.D. 28.58 X31.8 2 I.D. I.D. 25.4 O.D. 28.58 I.D. 41.3 I.D. I.D. 15.88 22.2 I.D. 28.58 I.D. 19.05 X2 I.D. 12.7 I.D. 28.58 I.D. 28.58 I.D. 12.7 I.D. 28.58 34.9 I.D. 22.2 I.D. 19.05 I.D. 28.58O.D. I.D. 15.88 I.D. 28.58 O.D. 9.52 O.D. 34.9 I.D. 31.8 O.D. 28.58 O.D. 28.58 O.D. 19.05 I.D. 15.88 I.D. 22.2I.D. 12.7 I.D. 9.52I.D. 25.4 I.D. 31.8 O.D. 19.05 I.D. 6.35 I.D.19.05 31.8 O.D. 25.4 I.D. 25.4 O.D. 28.58 I.D. 25.4 I.D. 12.7 I.D. 22.2 I.D. I.D. 22.2 I.D. 12.7 I.D. 12.7 I.D. 38.1 I.D. 15.88 I.D. 19.05 O.D. 9.52 I.D. 9.52 O.D. 28.58 O.D. 19.05 O.D. 9.52 I.D. 9.52 I.D. 15.88 I.D. 12.7 O.D. 19.05 O.D. 28.58 I.D. 6.35 O.D. 19.05 I.D. 9.52 I.D. I.D. 19.05 O.D. X I.D. 22.2 25.4 O.D. 19.05 I.D. 6.35 I.D.12.7 28.58 I.D. 12.7 I.D. 19.05 O.D.225.4 I.D. 22.2 I.D. 15.88 I.D. 12.7 I.D. 15.88 I.D. 28.58 O.D. 34.9 I.D. 28.58 I.D. 15.88 I.D. 31.8 I.D. 25.4 O.D. 28.58 I.D. 22.2 I.D. 12.7 I.D. 9.52 I.D. 9.52

X2

I.D. 31.8 I.D. 31.8 I.D. 25.4 I.D. 25.4

I.D. 25.4 I.D. 22.2 I.D. 22.2 I.D. 28.58

I.D. 19.05 I.D. 19.05


I.D. 15.88

I.D. 28.58 I.D. 34.9 I.D. 34.9 I.D. 15.88 I.D. 28.58 I.D. 12.7 I.D. 19.05 I.D. 28.58 I.D. 12.7 I.D. 19.05 I.D. 9.52

I.D. 15.88 I.D. 12.7 I.D. 19.05 I.D. 15.88

I.D. 34.9

I.D. 19.05 I.D. 28.58

I.D. 19.05 I.D. 19.05 I.D. 28.58 I.D. 28.58


I.D. 19.05

& Accessory

I.D.53.98 1 I.D.44.48 420 490

I.D.44.48 I.D41.3 I.D38.1 2 I.D41.3 I.D.44.48 I.D38.1 134 3

I.D. 19.05 O.D. 25.4


I.D25.4 I.D22.2

I.D. 12.7 O.D. 19.05 I.D. 15.88


I.D.22.2

O.D. 9.52 I.D. 6.35


I.D.19.05 2

I.D.25.4

I.D34.9 I.D. 22.2 I.D41.3

O.D. 28.58

O.D. 19.05

I.D38.1 I.D. 12.7

I.D. 9.52 I.D34.9

I.D28.58 2

I.D38.1 471 517 I.D19.05 I.D15.88 O.D38.1 I.D41.3 O.D22.2

I.D28.58 I.D34.9 I.D22.2 3

125

I.D.25.4 I.D.22.2 I.D.19.05 96 346 379 I.D.15.88 I.D.12.7 X2 110 3 110


3 O.D15.88 I.D12.7 70

ARBLB23220

I.D.34.9 O.D.38.1 2 3

I.D31.8 I.D.28.58 X2 175 I.D12.7 3 O.D.44.48 2 3

3
O.D34.9 3 90 O.D28.58 2 120 130 I.D22.2 I.D19.05 I.D38.1 I.D41.3

I.D.53.98

I.D.25.4 I.D.22.2 O.D.28.58 X2 3 115 I.D.19.05 I.D.15.88

I.D9.52 O.D12.7 I.D6.35

3 120

O.D.19.05 2 3

100 3 70 O.D.22.2 120

O.D15.88

202

203

Brand Power
LGs consistent efforts in innovation have made LG Air Conditioning and Energy Solution a true global leader in HVAC businesses.

Manufactured Koreas first air conditioner

Changed company name to LG Electronics

Became worlds leading seller of residential air conditioners

Introduced worlds first two-in-one air conditioner

1968 1958
Founded as GoldStar

1995 1990
Produced first rotary compressor

2000 1998
Produced Koreas first commercial air conditioner

2002 2001
Introduced the worlds first picture frame air conditioner

2006 2004
Achieved worlds highest annual sales in air conditioners of 10 million units

three-in-one Inverter

Structured as an independent business unit as part of LG Electronics reorganisation

Acquired the air-conditioning business of LS Mtron To strengthenLGs production of chillers and large scale air conditioning systems

Residential

2009 2008
Reached total global sales of 100 million air conditioner units for the first time in the industry

2011 2010
Established lighting business to provide total HVAC and energy solution worldwide

Total Air Conditioning Business

Commercial
Launched in 2009, LG Electronics Air Conditioning & Energy Solution Company (LG AE) provides total solutions in heating, ventilation and air conditioning (HVAC). LG AEs offerings include residential and commercial air conditioners, lighting, home and building management systems. LG AE was formed as part of the companys strategic plan to expand its business horizons into the B2B sector, reinforcing its presence in the commercial products and solutions business. In 2010, along with aggressive reinforcement of its position in commercial air conditioning, LG established lighting businesses to further increase its focus on B2B and on energy efficient business solutions. Based on its great success in the consumer market, the new Air Conditioning and Energy Solution Company allows LG to be more competitive in the commercial heating, ventilation, air conditioning (HVAC) and energy businesses worldwide. LG expects its strength in air conditioners to become a strong driver of growth for the entire company as the industry expands. Through its relentless efforts in innovation and development, LG AE is continuing to consolidate its leadership as a global HVAC and energy solution company, with a central focus on eco-friendliness and energy efficiency.

Chiller

BRAND

Quality Control

Development
Performance Test (Cool/Heat) EER Test Abnormal Noise Test Reliability Test Safety Test Air current Distribution Test Temp./Humidity Performance Test Difference of altitude Test E.M.I (Electromagnetic Interference) E.M.S (Electromagnetic Susceptibility) E.M.C (Electromagnetic Compatibility)

Quality Assurance Lab


Testing labs are equipped with certified equipment and facilities to ensure product reliability and leading technology

Mass Production
IQC
Part Life Test (ELT) 6sigma Distribution Control Vendor Quality Improvement Consulting

PL (Product Liability)
Safety Evaluation
Product Safety Check PL Consulting List
Noise Testing Chamber Environmental Testing Chamber Long Piping and Elevation Testing

LQC
Basic Performance Inspection Safety Inspection Movement/Structure/ Appearance Inspection

Test Product Safety


Fire Test Fire Chamber

LG Energy Lab
The LG Energy Lab is located in the town of Wargnies-Le-Petit, near Valenciennes, Northern France. It is used to field-test upcoming Residential and Commercial Air Conditioning and Heating products. The aim of the Energy Lab is to guarantee the reliability of new air conditioning and heating products in all seasons, even in extreme weather conditions, before they are commercially available.

OQC
Structure / Appearance inspection Early Life Test (ELT) Smog Test (Refrigerant leakage)

Assure Part Safety


Evaluation Safety PartVendor Audit

Standard Management
ISO 9001
Certificate Quality Management System
LG Electronics (Global Standard) Certificate Authority : UL Korea

KS
Certificate A/C Production System of
LG Electronics (Korea Standard)

Certificate Authority : Korea Standard


Association

KOLAS
L  G Electronics Revision System :
State Organ (International Authorization) C  ertificate Authority : The Ministry of Commerce Measuring Instruments in Factory: Self Revision

UL TCP
UL recognize LG Product
through a test result (In LG)

Certificate Authority : UL

206

207