Sie sind auf Seite 1von 56

Spec Sheet

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM

PUBLICATION HISTORY REV B.4 AUGUST 16, 2013

CONTENTS
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 7 CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP STEP 1 VERIFY BASE SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2 CHOOSE CPU(S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3 CHOOSE MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs . . . . . . . . . . . . . . . . . . . . . . 18 5 CHOOSE RAID CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 6 CHOOSE PCIe OPTION CARD(S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . 25 8 ORDER POWER SUPPLIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 9 SELECT AC POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 10 ORDER OPTIONAL SLIDE RAIL KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 11 ORDER OPTIONAL CABLE MANAGEMENT ARM . . . . . . . . . . . . . . . . . . . . . . . . . . 33 12 ORDER OPTIONAL INTERNAL FLASH eUSB DRIVE . . . . . . . . . . . . . . . . . . . . . . . . 34 13 ORDER A TRUSTED PLATFORM MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 14 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . 36 15 CHOOSE OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 16 CHOOSE SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

OPTIONAL STEP - ORDER RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 CPUs and DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Physical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Memory Population Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . Environmental Specifications . . . . . . . . . . . . . . . . . . . Compliance Requirements . . . . . . . . . . . . . . . . . . . . . .... .... .... .... ... ... ... ... .... .... .... .... .... .... .... .... ... ... ... ... .... .... .... .... . . 53 . . 53 . . 54 . . 54

TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Cisco UCS C460 M2 High-Performance Rack-Mount Server

OVERVIEW

OVERVIEW
The Cisco UCS C460 M2 High-Performance Rack Server (Figure 1) is a four-rack-unit (4RU) server supporting the Intel Xeon processor E7-4800 and E7-8800 product families, with up to 2 terabytes (TB) of double-data-rate 3 (DDR3) memory in 64 slots, and up to 12 small form factor (SFF), hot-pluggable SAS and SATA disk drives. 10 PCI Express (PCIe) slots support the Cisco UCS C-Series network adapters, with an eleventh PCIe slot reserved for a hard disk drive array controller card. Additional I/O is provided by 2 Gigabit Ethernet LOM ports, 2 10-Gigabit Ethernet ports, and 2 dedicated out-of-band (OOB) management ports. Figure 1 Front View Cisco UCS C460 M2 High-Density Rack Server

Rear View

Cisco UCS C460 M2 High-Performance Rack-Mount Server

DETAILED VIEWS

DETAILED VIEWS
Chassis Front View
Figure 2 is a detailed front view of the Cisco UCS C460 M2 General-Purpose Rack Server. Figure 2 Chassis Front View

3 2 4 5 6 7 8 9 10

1 2 3 4 5

HDDs (up to 12) SATA DVD drive Fans (up to 8) Power supply status LED Memory status LED

6 7 8 9 10

CPU status LED Network activity LED Operations panel (see Figure 3 on page 5 for a detailed view) VGA connector USB ports (3)

Figure 3 is a detailed view of operator panel.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

198383

DETAILED VIEWS

Figure 3

Chassis Front View

3 1 2 4

5 6 7

8 9

1 2 3 4 5

ID LED ID button HDD fault LED System health LED Fan fault LED

197617

6 7 8 9

Power status LED Power button Reset button NMI button

Cisco UCS C460 M2 High-Performance Rack-Mount Server

DETAILED VIEWS

Chassis Rear View


Figure 4 shows the external features of the rear panel. Figure 4 Chassis Rear View

7 6 5 4 3

10

11 12

2 1

1 2 3 4 5 6

Power supplies (up to 4) ID button USB ports (2 total) VGA connector 10GBase-T LOM ports, two total SAS riser slot

7 8 9 10 11 12

10G SFP+ LOM ports, two total 1 Gigabit LOM ports (2 total) 10/100 Management ports M1 and M2 Serial connector PCIe slots 1 through 10 (left to right as shown) Power supply LEDs

Cisco UCS C460 M2 High-Performance Rack-Mount Server

198384

BASE SERVER STANDARD CAPABILITIES and FEATURES

BASE SERVER STANDARD CAPABILITIES and FEATURES


Table 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER on page 10. Table 1 Capabilities and Features Capability/Feature Chassis CPU Description Four rack unit (4RU) chassis Either 2 or 4 Intel Xeon E7-8800/4800 family processors Two-CPU configurations require 2 power supplies Four-CPU configurations require 4 power supplies Chipset Memory Intel 7500 chipset and Intel 7510 scalable memory buffer Eight slots for memory riser boards. Each memory riser can hold up to 8 DIMMs, for a maximum DIMM population of 64 DIMMs. Maximum memory capacity is 2 TB. This is accomplished with 64 DIMMs, consisting of 32 DIMM kits (2 32 GB matched DIMMs per kit) in a 4-CPU configuration. USB Flash drive Expansion slots Optional 2 GB internal eUSB flash drives (up to 2) can be used as bootable drives There are 10 PCIe expansion slots:

Slots 1 and 2: Gen 2x8, 3/4 length card, x24 hot-swappable connectors Slots 3 and 4: Gen 2x4, 1/2 length card, x8 connectors Slot 5: Gen 2x16, 3/4 length card, x16 connector Slots 6 and 7: Gen 2x8, 3/4 length card, x8 hot-swappable connectors Slot 8: Gen 1x4, 3/4 length card, x8 connector Slot 9: Gen 1x4, 1/2 length card, x8 connector Slot 10: Gen 2x4, 1/2 length card, x8 connector NOTE: CPU3 must be installed to support PCIe slots 5, 6, 7, 9, and 10. Legacy I/O devices like video cards are only supported on slots 1,2,3, 4 and 8.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1 Capabilities and Features (continued) Capability/Feature Storage controller Description Factory-configured RAID support options:

RAID 0, 1, 5, 6, 10, 50, and 60 support for up to 12 SAS or SATA drives with either the optional LSI MegaRAID SAS 9260-8i controller, or RAID 0 and 1 support for up to 8 SAS or SATA drives with the optional LSI MegaRAID 9240-8I RAID controller.

There is a dedicated SAS riser slot in the chassis for either RAID controller card. There is also a location inside the chassis for the optional LSI RAID battery backup unit that can be used with the 9260-8i controller card. Internal storage devices Up to 12 SFF 2.5 SAS or SATA hard disk drives (HDDs) or solid state drives (SSDs).

Video

The server CIMC chip includes a Matrox G200 core. The first 8 MB of memory are allocated to the video core.

1280 x 1024 resolution 32-bit color depth 8 MB video memory Rear panel Two 10/100 dedicated management Ethernet ports Two 1-Gigabit ports (10/100/1000 Mbps capable). These integrated Gigabit ports support the Wake on LAN (WoL) and TCP/IP Offload Engine (TOE) standards Two 10-Gigabit Base-T Ethernet ports Two 10-Gigabit SFP+ Ethernet ports One RS232 serial connector One 15-pin VGA connector Two USB 2.0 connectors

Interfaces

Front panel One 15-pin VGA connector Three USB 2.0 connectors

Cisco UCS C460 M2 High-Performance Rack-Mount Server

BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1 Capabilities and Features (continued) Capability/Feature Power subsystem Description


Either 2 or 4 850 W power supplies Power supplies are hot-swappable, rear-accessible, and redundant as 2+2 or 3+1 NOTE: You can use 2 power supplies with a 2-CPU configuration. In this case, 1+1 redundancy is supported only if your servers overall power consumption can be supported by a single 850W power supply during the failure and hot-swap. For more information about your servers power consumption, use the power calculator accessible at http://www.cisco.com/assets/cdc_content_elements/flash/dataC enter/cisco_ucs_power_calculator/

Fans

Chassis:

8 fans, hot-swappable Each of the 4 power supplies is equipped with a fan.

Power supply:

Integrated management processor

The built-in Cisco Integrated Management Controller (CIMC) GUI or CLI interface enables you to monitor the server inventory, health, and system event logs.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

CONFIGURING the SERVER


Follow these steps to configure the Cisco UCS C460 M2 High-Performance Rack Server:

STEP 1 VERIFY BASE SKU, page 11 STEP 2 CHOOSE CPU(S), page 12 STEP 3 CHOOSE MEMORY, page 13 STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs, page 18 STEP 5 CHOOSE RAID CONFIGURATION, page 20 STEP 6 CHOOSE PCIe OPTION CARD(S), page 22 STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 25 STEP 8 ORDER POWER SUPPLIES, page 28 STEP 9 SELECT AC POWER CORD(s), page 29 STEP 10 ORDER OPTIONAL SLIDE RAIL KIT, page 32 STEP 11 ORDER OPTIONAL CABLE MANAGEMENT ARM, page 33 STEP 12 ORDER OPTIONAL INTERNAL FLASH eUSB DRIVE, page 34 STEP 13 ORDER A TRUSTED PLATFORM MODULE, page 35 STEP 14 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 36 STEP 15 CHOOSE OPERATING SYSTEM MEDIA KIT, page 39 STEP 16 CHOOSE SERVICE and SUPPORT LEVEL, page 40 OPTIONAL STEP - ORDER RACKS on page 45 OPTIONAL STEP - ORDER PDU on page 46

10

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

STEP 1

VERIFY BASE SKU

Verify the product ID (PID) of the base server as shown in Table 2. Table 2 PID of the Base C460 M2 Rack Server Product ID (PID) UCSC-BASE-M2-C460 Description UCS C460 M2 Rack SVR w/o CPU, Mem, HDD, PCIe

The base server:

Includes: Two 850 W power supplies (required for 2-CPU systems) Blanking panels for empty drive locations (to maintain cooling air flow) Cable management arm Rail kit

Does not include: Third and fourth 850 W power supplies (required for 4-CPU systems) CPUs Four empty memory riser boards (for 2-CPU systems) or 8 empty memory riser boards (for 4-CPU systems) Hard disk drives (HDDs) Solid-state Drives (SSDs) Plug-in PCIe cards. NOTE: Use the steps on the following pages to configure the server with the components that you want to include.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

11

CONFIGURING the SERVER

STEP 2

CHOOSE CPU(S)
Intel Xeon E7-8800 or E7-4800 (Westmere EX) series CPUs Intel 7500 chipset and Intel 7510 scalable memory buffer Cache size of 18, 24, or 30 MB

The standard CPU features are:


Choose CPUs The available CPUs are listed in Table 3. Table 3 Available CPUs: Intel Xeon Westmere E7-48xx/88xx Family Product ID (PID) UCS-CPU-E78837 UCS-CPU-E74870 UCS-CPU-E74860 UCS-CPU-E78867L UCS-CPU-E74830 UCS-CPU-E74850 UCS-CPU-E74807 Intel Number E7-8837 E7-4870 E7-4860 E7-8867L E7-4830 E7-4850 E7-4807 Clock Freq (GHz) 2.67 2.40 2.26 2.13 2.13 2.00 1.86 Power (W) 130 130 130 105 105 130 95 Cache Size (MB) 30 30 24 30 24 24 18 Cores 8 10 10 10 8 10 6 QPI 6.40 6.40 6.40 6.40 6.40 6.40 4.80 Highest DDR3 DIMM Clock Support (MHz) 1066 1066 1066 1066 1066 1066 1066

Approved Configurations (1) Two-CPU Configuration

Choose two identical CPUs from Table 3.

(2) Four-CPU Configuration

Choose four identical CPUs from Table 3.

Caveats

You must select either two or four identical processors.

12

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

STEP 3

CHOOSE MEMORY
Plug-In Memory Riser Boards Up to eight DIMMs per riser board Riser boards plug vertically into the motherboard Up to two riser boards per CPU (total maximum of eight per system)

The standard memory features are:

DIMMs Clock speed: 1066 MHz Ranks per DIMM: 1, 2, or 4 Operational voltage: 1.5 or 1.35 V Registered

Each CPU controls four serial memory interface (SMI) channels. Memory buffers on the memory risers convert each SMI channel into two DDR3 subchannels. There are two memory risers for each CPU. Memory is organized as two paired-DIMM kits (4 DIMMs) per memory channel, as shown in Figure 5.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

13

CONFIGURING the SERVER

Figure 5

C460 M2 Memory Organization

14

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

Choose Memory Riser Boards You may choose four memory riser boards for a two-CPU system or eight memory riser boards for a four-CPU system. Table 4 Available Memory Riser Boards Product ID (PID) Riser Board Options UCSC-MRB-002-C460 Memory riser board for C460 M2 server only 8 PID Description Max DIMMs per Riser

Approved Configurations (1) Two-CPU System

Choose four memory riser boards from Table 4.

(1) Four-CPU System

Choose eight memory riser boards from Table 4.

Caveats

You should order enough risers with enough sockets to accommodate your maximum forseeable memory needs.

Choose DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mirroring option are listed in Table 5. NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel. A transient or soft error in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

15

CONFIGURING the SERVER

DIMMs are orderable as kits, with two DIMMs per kit. Choose the desired number of DIMMs and the memory mirroring option if desired. The available memory DIMMs are listed in Table 5. Table 5 Available DDR3 DIMM Kits (2 DIMMs per Kit) Product ID (PID) DIMM Options UCS-MR-2X041RX-C UCS-MR-2X082RX-C UCS-MR-2X164RX-C UCS-MR-2X324RX-C 2X4GB DDR3-1333-MHz RDIMM/PC3-10600/single rank/x4/1.35v 1.5/1.35 2X8GB DDR3-1333-MHz RDIMM/PC3-10600/dual rank/x2/1.35v 1.5/1.35 1 2 4 4 PID Description Voltage (V) Ranks/ DIMM

2X16GB DDR3-1333-MHz RDIMM/PC3-10600/quad rank/x4/1.35v 1.5/1.35 2x32GB DDR3-1333-MHz RDIMM/PC3-10600/quad rank/x4/1.35v 1.5/1.35

Memory Mirroring Option N01-MMIRROR Memory mirroring option

Approved Configurations (1) Minimum Configuration without memory mirroring

One memory riser with at least one matched DIMM pair. The memory riser must be installed in a slot controlled by either CPU1 or CPU2. All four CPUs can run from a single DIMM pair.

(2) Maximum Configuration without memory mirroring

Eight memory risers with at least one matched DIMM pair per riser (16 DIMMs total) and up to four matched DIMM pairs per riser (64 DIMMs total).

(3) Minimum Configuration with memory mirroring

One memory riser with at least two matched DIMM pairs.

(4) Maximum Configuration with memory mirroring

Eight memory risers with at least two matched DIMM pairs per riser (16 DIMMs total) and up to four matched DIMM pairs per riser (64 DIMMs total). NOTE: There are three memory mirroring modes: 1 Intra-socket mirroring 2 Inter-socket cross-memory-controller mirroring 3 Inter-socket complete master-slave mirroring Mirroring mode can be configured using the UCS Manager BIOS Policy RAS Memory tab

16

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

Caveats

Each CPU controls four DDR3 channels. The minimum DIMM configuration is at least one matched DIMM pair installed in a memory riser on either CPU1 or CPU2. All four CPUs can run from a single DIMM pair. DIMMs are required to be populated in pairs. DIMMs for this server are available as two-DIMM kits. The DIMMs in any given pair must be identical. Any DIMM installed in a memory riser corresponding to an empty CPU slot becomes inaccessible. For optimal performance, distribute DIMMs evenly across all installed CPUs and memory buffers. DIMMs within a channel are populated starting with the DIMMs farthest from the memory buffer in a fill-farthest approach. Matched pairs of risers on paired DDR3 channels must have identical DIMM configurations.

For more information about memory, see CPUs and DIMMs on page 48.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

17

CONFIGURING the SERVER

STEP 4

CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs


2.5-inch small form factor Hot-pluggable Sled-mounted

The standard disk drive features are:


Choose Drives The available drives are listed in Table 6. Table 6 Available Hot-Pluggable Sled-Mounted HDDs and SSDs Product ID (PID) HDDs A03-D146GC2 A03-D300GA2 UCS-HDD300GI2F105 A03-D500GC3 A03-D600GA2 UCS-HDD900GI2F106 A03-D1TBSATA SSDs UCS-SSD100GI1F104 UCS-SD100G0KA2-E UCS-SD100G0KA2-G UCS-SD200G0KA2-E UCS-SD300G0KA2-E UCS-SD400G0KA2-G 100 GB SATA SSD 100 GB SATA 2.5 inch Enterprise Performance SSD 100 GB 2.5 inch Enterprise Value SSD 200 GB 2.5 SATA Enterprise performance SSD 300 GB 2.5 SATA Enterprise performance SSD 400 GB 2.5 Enterprise Value SSD SATA SATA SATA SATA SATA SATA 100 GB 100 GB 100 GB 200 GB 300 GB 400 GB 146 GB SAS 15K RPM SFF HDD 300 GB 6 Gb SAS 10K RPM SFF HDD 300 GB 6 Gb SAS 15K RPM SFF HDD 500 GB 6 Gb SATA 7.2K RPM SFF 600 GB 6 Gb SAS 10K RPM SFF HDD 900 GB 6Gb SAS 10K RPM SFF HDD 1 TB SATA 7.2K RPM SFF HDD SAS SAS SAS SATA SAS SAS SATA 146 GB 300 GB 300 GB 500 GB 600 GB 900 GB 1 TB PID Description Drive Type Capacity

Approved Configurations (1) LSI MegaRAID SAS 9260-8i RAID controller (battery backup is optional)

Select up to 12 SAS or SATA drives listed in Table 6 (you can mix SAS/SATA drives, but not HDD/SSD drives). This configuration supports RAID 0, 1, 5, 6, and 10.

18

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

(2) LSI MegaRAID SAS 9240-8i RAID controller (no battery backup)

Select up to 8 SAS or SATA drives listed in Table 6 (you can mix SAS/SATA drives, but not HDD/SSD drives). This configuration supports RAID 0and 1.

Caveats

You cannot mix HDDs and SSDs.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

19

CONFIGURING the SERVER

STEP 5

CHOOSE RAID CONFIGURATION

The C460 M2 server accommodates either an LSI MegaRAID SAS 9260-8i or LSI MegaRAID SAS 9240-8i RAID controller. The C460 M2 contains a drive bay housing up to 12 HDDs or SSDs. Cisco can provide factory-configured RAID 0, 1, 5, 6, and 10 systems depending on the RAID implementation chosen, the RAID controller chosen, and the number of drives ordered. Factory-configured RAID options are listed at the end of Table 7. Note that RAID levels 50 and 60 are supported on the 9260-8i, but are not factory configurable. Choose RAID Options Choose one RAID controller, one RAID configuration option, and, if desired, the battery backup option listed in Table 7. Table 7 Available RAID Options Product ID (PID) RAID Controllers RC460-PL001 LSI MegaRAID SAS 9260-8i (RAID 0, 1, 5, 6, 10, 50, 60 supported)

PID Description

Plugs into the dedicated SAS riser on the rear of the server on the left (see Figure 4 on page 6). Supports from 1 to 12 internal SAS or SATA drives Battery backup (R2XX-LBBU2) is required (see the RAID Battery Backup section later in this table) Factory-configured RAID options: RAID 0, 1, 5, 6, 10 (see the RAID PIDs section in this table) Plugs into the dedicated SAS riser on the rear of the server on the left (see Figure 4 on page 6). Supports from 1 to 8 internal SAS or SATA drives Battery backup option not available Factory-configured RAID options: RAID 0 and 1 (see the RAID PIDs section in this table)

RC460-PL002

LSI MegaRAID SAS 9240-8i (RAID 0 and 1)


RAID Battery Backup Option R2XX-LBBU2 RAID Configuration R2XX-RAID0 R2XX-RAID1 Factory pre-configured RAID striping option Enable RAID 0 Setting. Requires a minimum of 1 hard drive. Factory pre-configured RAID mirroring option Enable RAID 1 Setting. Requires exactly 2 drives, with same size, speed, capacity. Battery Backup (for LSI MegaRAID SAS 9260-8i controller only)

20

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

Table 7 Available RAID Options (continued) Product ID (PID) R2XX-RAID5 R2XX-RAID6 R2XX-RAID10 PID Description Factory pre-configured RAID option Enable RAID 5 Setting. Requires minimum 3 drives of same size, speed, capacity. Factory pre-configured RAID option Enable RAID 6 Setting. Requires minimum 4 drives of same size, speed, capacity. Factory pre-configured RAID option Enable RAID 10 Setting. Requires an even number of drives (minimum 4 drives) of same size, speed, capacity.

. NOTE: No RAID option can be chosen if you have one of the following configurations: A mix of SAS and SATA drives No drives Approved Configurations (1) One RAID Controller Card

Choose either the RC460-PL001 LSI MegaRAID SAS 9260-8i RAID controller or the RC460-PL002 LSI MegaRAID SAS 9240-8i RAID controller listed in Table 7. You will be able to control from 1 to 12 drives with the 9260-8i RAID controller and from 1 to 8 drives with the 9240-8i RAID controller.

Caveats

The RAID controller card is preinstalled in a dedicated SAS riser slot in the rear of the server. See Figure 4 on page 6. You can choose an optional RAID configuration (RAID 0, 1, 5, 6, or 10), which is pre-configured at the factory. If you do not choose a RAID configuration, the disks will be configured as a JBOD.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

21

CONFIGURING the SERVER

STEP 6

CHOOSE PCIe OPTION CARD(S)


Converged Network Adapters (CNA) Network Interface Cards (NICs) Host Bus Adapters (HBAs)

The standard PCIe card offerings are:


Choose PCIe Option Cards The available PCIe option cards are listed in Table 8. Table 8 Available PCIe Option Cards Product ID (PID) PID Description Card Height Half Half Half Half Half Half Half Half Half Half Half Half N/A

Converged Network Adapters (CNA) N2XX-AEPCI01 UCSC-PCIE-BSFP UCSC-PCIE-BTG UCSC-PCIE-CSC-02 UCSC-PCIE-C10T-02 UCSC-PCIE-QSFP N2XX-ABPCI03-M3 N2XX-AIPCI01 N2XX-AEPCI03 N2XX-AEPCI05 N2XX-AQPCI03 N2XX-AQPCI05 UCSC-GPU-N01-C460
Notes . . .

Emulex OneConnect OCe10102-F CNA 2-port 10Gbps Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI Broadcom 57712 Dual Port 10GBASE-T w/TOE iSCSI Cisco VIC 1225 Dual Port 10Gb SFP+ CNA Cisco VIC 1225T Dual Port 10GBaseT CNA Qlogic QLE8242-CU Dual Port 10 GbE FCoE CNA Broadcom 5709 Quad Port 1Gb w/TOE iSCSI for M3 Servers Intel Dual Port 10 GbE Ethernet X520 Server Adapter Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Accessory Kit for NVIDIA Tesla C2050 GPU1 includes power cable, panels)

Network Interface Cards (NICs)

Host Bus Adapters (HBAs)

Computing Processor Accessory Kit

1. The NVIDIA Tesla card itself can be ordered from a certified NVIDIA Tesla reseller partner or distributor listed at the following link: http://www.nvidia.com/object/tesla_wtb.html#3. Note that the C2050 is a full-height PCIe x16 dual-slot form factor card and consumes 238 watts (max). It can be installed only in PCIe slot 5.

22

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

Approved Configurations (1) Select up to 10 PCIe Cards

Use Table 9 as a guide for adding PCIe cards. See Figure 6 for the slot locations.

Table 9 PCIe Expansion Slot Numbering Slot Number 1 and 2 3 and 4 5 6 and 7 8 9 10 Figure 6 PCIe Slot Locations Slot Characteristics PCIe Gen 2x8, 3/4 length card, x24 hot-swappable connectors PCIe Gen 2x4, 1/2 length card, x8 connectors PCIe Gen 2x16, 3/4 length card, x16 connector PCIe Gen 2x8, 3/4 length card, x8 hot-swappable connectors PCIe Gen 1x4, 3/4 length card, x8 connector PCIe Gen 1x4, 1/2 length card, x8 connector PCIe Gen 2x4, 1/2 length card, x8 connector

1 2

3 4

5 6 7

8 9
198935

10

Cisco UCS C460 M2 High-Performance Rack-Mount Server

23

CONFIGURING the SERVER

Caveats

CPU3 must be installed to support PCIe slots 5, 6, 7, 9, and 10. Legacy I/O devices such as video cards are only supported on slots 1, 2, 3, 4 and 8. The Cisco Card NIC mode is currently supported only with a Cisco 1225 VIC (UCSC-PCIE-CSC-02) that is installed in PCIe slot 1. The C460 server accommodates the Cisco 1225 Virtual Interface card, which is supported only in slots 1 and 2. Only one Cisco 1225 VIC can be used for both UCSM management and data traffic in the C460 M2 server The Cisco 1225 VIC in slot 1 handles management and data traffic. If a second Cisco 1225 VIC is installed in slot 2, it will be used for data traffic only. This is due to the standby power supplied only to slot 1.

All PCIe slots are standard-height and require a standard-height mounting bracket on the PCIe card. Additional considerations for the Cisco 1225 VIC card: Supports 10G SFP+ optical and copper twinax connections To use the Cisco Card NIC mode, this card must be installed in PCIe slot 1. Slot 1 can operate while the server is in standby power mode. Requires that the server has CIMC firmware version 1.4(6) or later installed. There is a heartbeat LED on the top of the card that indicates when firmware is active. To use this card for UCS integration (Cisco UCS Manager mode) with Cisco UCS Manager 2.1(0) or later, the minimum card-firmware and uboot image level is 2.1(0.306).

To help ensure that your operating system is compatible with the cards you have selected, please check the Hardware Compatibility List at this URL: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html

24

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

STEP 7

ORDER OPTIONAL NETWORK CARD ACCESSORIES

Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server. Choose Optional Twinax Cables Copper twinax cables are listed in Table 10. You can choose cable lengths of 1, 3, 5, 7, or 10 meters. The two longer cables (7 and 10 meters) are active, which means that they contain active components within the SFP+ housing to improve signal quality. Table 10 Available Twinax Cables Product ID (PID) SFP-H10GB-CU1M SFP-H10GB-CU3M SFP-H10GB-CU5M SFP-H10GB-ACU7M SFP-H10GB-ACU10M PID Description 10GBASE-CU SFP+ Cable (1 M) 10GBASE-CU SFP+ Cable (3 M) 10GBASE-CU SFP+ Cable (5 M) 10GBASE-CU SFP+ Cable (7 M) 10GBASE-CU SFP+ Cable (10 M)

Approved Configurations (1) Choose Up to Two Twinax Cables for Each Network Card Ordered

You may choose one or two twinax cables for each network card ordered. The cables can be different lengths; however, you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment.

Caveats The twinax cables listed in Table 10 can be ordered only for the following PCIe cards: UCS-PCIE-BSFP (Broadcom 57712) N2XX-AEPCI01 (Emulex OCe10102-F) N2XX-AIPCI01 (Intel Dual Port Ethernet X520) N2XX-AQPCI01 (Qlogic QLE 8152-CNA) UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)

Cisco UCS C460 M2 High-Performance Rack-Mount Server

25

CONFIGURING the SERVER

Choose Optional SFP Modules Optical Cisco SFP+ modules are listed in Table 11. Table 11 Available SFP Modules Product ID (PID) SFP-10G-SR DS-SFP-FC8G-SW PID Description 10GBASE-SR SFP+ Module 850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring 8 Gbit SFP+ Module 850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring

Approved Configurations (1) Choose Up to Two SFP+ Modules for Each Network Card Ordered

You may choose one or two SFP+ optical modules cables for each network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available.

See Figure 7 on page 27 for typical SFP+ and twinax connections to the network cards. Caveats The SFP-10G-SR optical module listed in Table 11 should be ordered only for the following PCIe cards, as they do not come by default with any optical modules: UCSC-PCIE-BSFP (Broadcom 57712) N2XX-AEPCI01 (Emulex OCe10102-F) UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)

The DS-SFP-FC8G-SW optical module listed in Table 11 should be ordered only for the following PCIe cards, as they do not come by default with any optical modules: N2XX-AEPCI05 (Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA)

26

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

Figure 7

Network Card Connections

Cisco UCS C460 M2 High-Performance Rack-Mount Server

27

CONFIGURING the SERVER

STEP 8

ORDER POWER SUPPLIES

If you ordered a 2-CPU system, the base server comes with two power supplies, which is adequate to power the server. If you ordered a 4-CPU system, you must order two additional power supplies, listed in Table 15. Table 12 Power Supplies PID Description 850W POWER SUPPLY UNIT FOR C-SERIES C460

Product ID (PID) RC460-PSU2-850W

28

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

STEP 9

SELECT AC POWER CORD(s)

Select the appropriate AC power cords listed in Table 13. You may select a minimum of no power cords and a maximum of two power cords. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server. Table 13 Available Power Cords Product ID (PID) R2XX-DMYMPWRCORD CAB-N5K6A-NA PID Description No power cord (dummy PID to allow for a no power cord option) Power Cord, 200/240V 6A, North America
Plug: NEMA 6-15P Cordset rating: 10 A, 250 V Length: 8.2 ft

Images Not applicable

CAB-AC-L620-C13

AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft

CAB-C13-CBN

CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V

CAB-C13-C14-2M

CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V

CAB-C13-C14-AC

CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M

Cisco UCS C460 M2 High-Performance Rack-Mount Server

186570

Connector: IEC60320/C13

29

CONFIGURING the SERVER

Table 13 Available Power Cords Product ID (PID) SFS-250V-10A-AR PID Description Power Cord, SFS, 250V, 10A, Argentina
Plug: EL 219 (IRAM 2073)

Images
2500 mm

Cordset rating: 10 A, 250/500 V MAX Length: 8.2 ft

CAB-9K10A-AU

Power Cord, 250VAC 10A 3112 Plug, Australia


Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Connector: EL 701C (EN 60320/C15)

SFS-250V-10A-CN

Power Cord, SFS, 250V, 10A, China

Plug: EL 218 (CCEE GB2009)

Cordset rating 10A, 250V (2500 mm)

CAB-250V-10A-CN

AC Power Cord - 250V, 10A - PRC

CAB-9K10A-EU

Power Cord, 250VAC 10A CEE 7/7 Plug, EU


Plug: M2511 Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: VSCC15

SFS-250V-10A-ID

Power Cord, SFS, 250V, 10A, India


OVE

Plug: EL 208

Cordset rating 16A, 250V (2500mm) Connector: EL 701


187490

SFS-250V-10A-IS

Power Cord, SFS, 250V, 10A, Israel


-212 EL
16A 250V

Cordset rating 10A, 250V/500V MAX (2500 mm) Connector: EL 701B (IEC60320/C13)
186574

Plug: EL 212 (SI-32)

30

Cisco UCS C460 M2 High-Performance Rack-Mount Server

186576

186573

Connector: EL 701 (IEC60320/C13)

186580

Plug: EL 210 (BS 1363A) 13 AMP fuse

186571

Connector: EL 701 (IEC60320/C13)

CONFIGURING the SERVER

Table 13 Available Power Cords Product ID (PID) CAB-9K10A-IT PID Description Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy
Plug: I/3G (CEI 23-16) Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector C15M (EN60320/C15 )
186575

Images

CAB-9K10A-SW

Power Cord, 250VAC 10A MP232 Plug, Switzerland


Plug: MP232-R Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.5 m) Connector: IEC 60320 C15
186578

CAB-9K10A-UK

Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK


Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Connector: EL 701C (EN 60320/C15)

CAB-9K12A-NA

Power Cord, 125VAC 13A NEMA 5-15 Plug, North America

CAB-250V-10A-BR

Power Cord - 250V, 10A - Brazil


1
76.2 From Plug End

2,133.6 25

CAB-JPN-3PIN

Power Cord 3PIN, Japan

Image not available

Cisco UCS C460 M2 High-Performance Rack-Mount Server

186580

Plug: EL 210 (BS 1363A) 13 AMP fuse

31

CONFIGURING the SERVER

STEP 10 ORDER OPTIONAL SLIDE RAIL KIT


Two different optional slide rail kits can be ordered:

Tool-less slide rail kit (RC460-SLDRAIL) Short slide rail kit (RC460-SLDRAIL-S), where space is at a premium and a cable management arm is not needed

You can order one of the slide rail kits listed in Table 14. Table 14 Slide Rail Kits PID Description Slide rail kit for the UCS C460 rack server Short slide rail kit for C460, no CMA

Product ID (PID) RC460-SLDRAIL RC460-SLDRAIL-S

32

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

STEP 11 ORDER OPTIONAL CABLE MANAGEMENT ARM


A cable management arm is available for the tool-less slide rail kit (PID RC460-SLDRAIL). The cable management arm attaches to the left and right slide rails at the rear of the server and is used for cable management. You can order the cable management arm listed in Table 15. Table 15 Cable Management Arm PID Description Cable Management Arm for C460

Product ID (PID) RC460-CBLARM

Cisco UCS C460 M2 High-Performance Rack-Mount Server

33

CONFIGURING the SERVER

STEP 12 ORDER OPTIONAL INTERNAL FLASH eUSB DRIVE


One or two optional 2 GB eUSB drives may be ordered and used as a boot drive. The eUSB drives plug into vertical USB slots on the motherboard. You can order the eUSB boot drive listed in Table 16. Table 16 Available USB Drive Product ID (PID) RC460-EUSB PID Description 2 GB eUSB Drive Drive Type USB Capacity 2 GB

Approved Configurations

Select one or two eUSB drives from Table 16.

Caveats None

34

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

STEP 13 ORDER A TRUSTED PLATFORM MODULE


Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments. The TPM ordering information is listed in Table 17. Table 17 Trusted Platform Module PID Description Trusted Platform Module

Product ID (PID) UCSC-TPM-001-C460

Cisco UCS C460 M2 High-Performance Rack-Mount Server

35

CONFIGURING the SERVER

STEP 14 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE


Several operating systems and value-added software programs are available. Select as desired from Table 18. Table 18 OSs and Value-Added Software (for 4-CPU servers) PID Description Product ID (PID)

Microsoft Windows Server MSWS-08R2-STHV MSWS-08R2-ENHV MSWS-08R2-DCHV2S MSWS-12-ST2S MSWS-12-DC2S MSWS-12-ST2S-NS MSWS-12-DC2S-NS SLES-1A SLES-3A UCS-SLES-TERMS RHEL-2S-1G-1A RHEL-2S-1G-3A RHEL-2S-4G-1A RHEL-2S-4G-3A RHEL-2S-UG-1A RHEL-2S-UG-3A RHEL-4S-1G-1A RHEL-4S-1G-3A RHEL-4S-4G-1A RHEL-4S-4G-3A RHEL-4S-UG-1A RHEL-4S-UG-3A RHEL-HA-2S-1A RHEL-HA-2S-3A Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL) Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL) Windows Svr 2008 R2-2 CPU-Data Center Windows Server 2012 Standard (2 CPU/2 VMs) Windows Server 2012 Datacenter (2 CPU/Unlimited VMs) Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco Svc SLES/1yr subscription/svcs required/0 media SLES/3yr subscription/svcs required/0 media Acceptance of Terms, Standalone SLES License for UCS Servers RHEL/2 Socket/1 Guest/1Yr Svcs Required RHEL/2 Socket/1 Guest/3Yr Svcs Required RHEL/2 Socket/4 Guest/1Yr Svcs Required RHEL/2 Socket/4 Guest/3Yr Svcs Required RHEL/2 Socket/U Guest/1Yr Svcs Required RHEL/2 Socket/U Guest/3Yr Svcs Required RHEL/4 Socket/1 Guest/1Yr Svcs Required RHEL/4 Socket/1 Guest/3Yr Svcs Required RHEL/4 Socket/4 Guest/1Yr Svcs Required RHEL/4 Socket/4 Guest/3Yr Svcs Required RHEL/4 Socket/U Guest/1Yr Svcs Required RHEL/4 Socket/U Guest/3Yr Svcs Required RHEL Option/High-Availability/2 Socket/1Yr Svcs Required RHEL Option/High-Availability/2 Socket/3Yr Svcs Required

SUSE Linux Enterprise Server

Red Hat Enterprise Linux

36

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

Table 18 OSs and Value-Added Software (for 4-CPU servers) (continued) PID Description RHEL-HA-4S-1A RHEL-HA-4S-3A RHEL-RS-2S-1A RHEL-RS-2S-3A RHEL-RS-4S-1A RHEL-RS-4S-3A RHEL-SFS-2S-1A RHEL-SFS-2S-3A RHEL-SFS-4S-1A RHEL-SFS-4S-3A BMC BMC-002 BMC-012 BMC-SE-4C BMC-SE-6C BMC-SE-8C BMC-SE-10C BMC-AE-4C BMC-AE-6C BMC-AE-8C BMC-AE-10C UCS-BMC-TERMS VMWare 5 VMW-VS5-STD-1A VMW-VS5-STD-2A VMW-VS5-STD-3A VMW-VS5-STD-4A VMW-VS5-STD-5A VMW-VS5-ENT-1A VMW-VS5-ENT-2A VMW-VS5-ENT-3A VMW-VS5-ENT-4A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Rqd VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Rqd VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Rqd VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Rqd VMware vSphere 5 Standard for 1 Processor, 5 Year, Support Rqd VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support Rqd VMware vSphere 5 Enterprise for 1 CPU, 2 Yr Support Rqd VMware vSphere 5 Enterprise for 1 CPU, 3 Yr Support Rqd VMware vSphere 5 Enterprise for 1 Processor, 4 Year Support Rqd BMC BladeLogic CM, Physical Server BMC BPPM Per Server BMC BladeLogic Standard Edition, 4 Cores, Support Required BMC BladeLogic Standard Edition, 6 Cores, Support Required BMC BladeLogic Standard Edition, 8 Cores, Support Required BMC BladeLogic Standard Edition, 10 Cores, Support Required BMC BladeLogic Advanced Edition, 4 Cores, Support Required BMC BladeLogic Advanced Edition, 6 Cores, Support Required BMC BladeLogic Advanced Edition, 8 Cores, Support Required BMC BladeLogic Standard Edition, 10 Cores, Support Required Acceptance of Terms, Standalone BMC License for UCS Servers Product ID (PID) RHEL Option/High-Availability/4 Socket/1Yr Svcs Required RHEL Option/High-Availability/4 Socket/3Yr Svcs Required RHEL Option/Resilient Storage w/HA /2 Socket/1 Yr Svcs Reqd RHEL Option/Resilient Storage w/HA /2 Socket/3 Yr Svcs Reqd RHEL Option/Resilient Storage w/HA /4 Socket/1 Yr Svcs Reqd RHEL Option/Resilient Storage w/HA /4 Socket/3 Yr Svcs Reqd RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required RHEL Option/Scalable File System/4 Socket/1 Yr Svcs Required RHEL Option/Scalable File System/4 Socket/3 Yr Svcs Required

Cisco UCS C460 M2 High-Performance Rack-Mount Server

37

CONFIGURING the SERVER

Table 18 OSs and Value-Added Software (for 4-CPU servers) (continued) PID Description VMW-VS5-ENT-5A VMW-VS5-ENTP-1A VMW-VS5-ENTP-2A VMW-VS5-ENTP-3A VMW-VS5-ENTP-4A VMW-VS5-ENTP-5A VMW-VC5-STD-1A VMW-VC5-STD-2A VMW-VC5-STD-3A VMW-VC5-STD-4A VMW-VC5-STD-5A UCS-VMW-TERMS Product ID (PID) VMware vSphere 5 Enterprise for 1 CPU, 5 Yr Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor, 1 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 CPU, 2 Yr Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor, 3 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year Support Rqd VMware vCenter 5 Server Standard, 1 yr support required VMware vCenter 5 Server Standard, 2 yr support required VMware vCenter 5 Server Standard, 3 yr support required VMware vCenter 5 Server Standard, 4 yr support required VMware vCenter 5 Server Standard, 5 yr support required Acceptance of Terms, Standalone VMW License for UCS Servers

38

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

STEP 15 CHOOSE OPERATING SYSTEM MEDIA KIT


Choose the optional operating system media listed in Table 19. Table 19 OS Media PID Description RHEL 6 Recovery Media Only (Multilingual) SLES 11 media only (multilingual) Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media Windows Server 2012 Datacenter (2 CPU/Unlimited VM) Rec Media

Product ID (PID) RHEL-6 SLES-11 MSWS-08R2-STHV-RM MSWS-08RS-ENHV-RM MSWS-08R2-DCHV-RM MSWS-12-ST2S-RM MSWS-12-DC2S-RM

Cisco UCS C460 M2 High-Performance Rack-Mount Server

39

CONFIGURING the SERVER

STEP 16 CHOOSE SERVICE and SUPPORT LEVEL


A variety of service options are available, as described in this section. Unified Computing Warranty, No Contract If you have noncritical implementations and choose to have no service contract, the following coverage is supplied:

Three-year parts coverage. Next business day (NBD) onsite parts replacement eight hours a day, five days a week. 90-day software warranty on media. Ongoing downloads of BIOS, drivers, and firmware updates. UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards.

SMARTnet for UCS For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world. For UCS blade servers, there is Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Cisco SMARTnet for UCS Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in Table 20. Table 20 Cisco SMARTnet for UCS Service On Site? Yes Yes Yes Yes No No No No Description ONSITE 24X7X2 C460 M2 Rack Server ONSITE 24X7X4 C460 M2 Rack Server ONSITE 8X5X4 C460 M2 Rack Server ONSITE 8X5XNBD C460 M2 Rack Server SMARTNET 24X7X2 C460 M2 Rack Server SMARTNET 24X7X4 C460 M2 Rack Server SMARTNET 8X5X4 C460 M2 Rack Server SMARTNET 8X5XNBD C460 M2 Rack Server

Product ID (PID) CON-PREM-C460M2 CON-OSP-C460M2 CON-OSE-C460M2 CON-OS-C460M2 CON-S2P-C460M2 CON-SNTP-C460M2 CON-SNTE-C460M2 CON-SNT-C460M2

40

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

SMARTnet for UCS Hardware Only Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a service listed in Table 21. Table 21 SMARTnet for UCS Hardware Only Service Service Level GSP UCW7 UCW5 On Site? Yes Yes Description UC PLUS 24X7X4OS C460 M2 Rack Server UC PLUS 8X5XNBDOS C460 M2 Rack Server

Product ID (PID) CON-UCW7-C460M2 CON-UCW5-C460M2

Unified Computing Partner Support Service Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to help them:

Expand their service portfolios to support the most complex network environments Lower delivery costs Deliver services that increase customer loyalty

Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high-value technical support that capitalizes on Cisco intellectual assets. This helps partners to realize higher margins and expand their practice. PSS is available to all Cisco PSS partners, but requires additional specializations and requirements. For additional information, see the following URL: www.cisco.com/go/partnerucssupport The two Partner Unified Computing Support Options include:

Partner Support Service for UCS Partner Support Service for UCS Hardware Only

Cisco UCS C460 M2 High-Performance Rack-Mount Server

41

CONFIGURING the SERVER

Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support. See Table 22. Table 22 Partner Support Service for UCS Service Level GSP PSJ1 PSJ2 PSJ3 PSJ4 On Site? No No No No Description UCS SUPP PSS 8X5XNBD C460 M2 Rack Server UCS SUPP PSS 8X5X4 C460 M2 Rack Server UCS SUPP PSS 24X7X4 C460 M2 Rack Server UCS SUPP PSS 24X7X2 C460 M2 Rack Server

Product ID (PID) CON-PSJ1-C460M2 CON-PSJ2-C460M2 CON-PSJ3-C460M2 CON-PSJ4-C460M2

Partner Support Service for UCS Hardware Only provides customers with replacement parts in as little as two hours. See Table 23. Table 23 Partner Support Service for UCS (Hardware Only) Service Level GSP PSW2 PSW3 PSW4 On Site? No No No Description UCS W PL PSS 8X5X4 C460 M2 Rack Server UCS W PL PSS 24X7X4 C460 M2 Rack Server UCS W PL PSS 24X7X2 C460 M2 Rack Server

Product ID (PID) CON-PSW2-C460M2 CON-PSW3-C460M2 CON-PSW4-C460M2

Unified Computing Combined Support Service Combined Services makes it easier to purchase and manage required services under one contract. SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment. The more benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important the technology becomes to your business. These services allow you to:

Optimize the uptime, performance, and efficiency of your UCS Protect your vital business applications by rapidly identifying and addressing issues Strengthen in-house expertise through knowledge transfer and mentoring Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect your operations

42

Cisco UCS C460 M2 High-Performance Rack-Mount Server

CONFIGURING the SERVER

You can choose a service listed in Table 24. Table 24 UCS Computing Combined Support Service Service On Level Description Site? GSP

Product ID (PID)

CON-NCF2-C460M2 CON-NCF2P-C460M2 CON-NCF4P-C460M2 CON-NCF4S-C460M2 CON-NCFCS-C460M2 CON-NCFE-C460M2 CON-NCFP-C460M2 CON-NCFT-C460M2

NCF2 NCF2P NCF4P NCF4S NCFCS NCFE NCFP NCFT

No Yes Yes Yes Yes No No No

CMB SPT SVC 24X7X2 C460 M2 Rack Server


CMB SPT SVC 24X7X2OS C460 M2 Rack Server CMB SPT SVC 24X7X4OS C460 M2 Rack Server CMB SPT SVC 8X5X4OS C460 M2 Rack Server CMB SPT SVC 8X5XNBDOS C460 M2 Rack Server CMB SPT SVC 8X5X4 C460 M2 Rack Server

CMB SPT SVC 24X7X4 C460 M2 Rack Server


CMB SPT SVC 8X5XNBD C460 M2 Rack Server

Unified Computing Drive Retention Service With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed. Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements. If your company has a need to control confidential, classified, sensitive, or proprietary data, you might want to consider one of the Drive Retention Services listed in Table 25. NOTE: Cisco does not offer a certified drive destruction service as part of this service.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

43

CONFIGURING the SERVER

Table 25 Drive Retention Service Options Service Description SMARTnet for UCS Service with Drive Retention SMARTnet for UCS HW ONLY+Drive Retention Service Program Name UCS DR Service Level GSP UCSD7 UCSD7 UCWD7 UCWD5 Service Level 24x7x4 Onsite 8x5xNBD Onsite 24x7x4 Onsite 8x5xNBD Onsite Product ID (PID) CON-UCSD7-C460M2 CON-UCSD5-C460M2 CON-UCWD7-C460M2 CON-UCWD5-C460M2

UCS HW+DR

For more service and support information, see the following URL:
http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf

For a complete listing of available services for Cisco Unified Computing System, see this URL:
http://www.cisco.com/en/US/products/ps10312/serv_group_home.html

44

Cisco UCS C460 M2 High-Performance Rack-Mount Server

OPTIONAL STEP - ORDER RACKS

OPTIONAL STEP - ORDER RACKS


The optional R42610 rack is available from Cisco for the C-Series servers, including the C460 M2 server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in Table 26. Racks are shipped separately from the C460 M2 server. Table 26 Racks and Rack Options PID Description Cisco R42610 expansion rack, no side panels Cisco R42610 standard rack, w/side panels Filler panels (qty 12), 1U, plastic, toolless Cable mgt D rings (qty 10), metal Cable mgt straps (qty 10), Velcro Mounting screws (qty 100), M6 Cage nuts (qty 50), M6 Rack joining kit

Product ID (PID) RACK-UCS1 RACK-UCS21 RACK-BLANK-001 RACK-CBLMGT-001 RACK-CBLMGT-011 RACK-FASTEN-001 RACK-FASTEN-002 RACK-JOIN-001
Notes . . .

1. Use these same base PIDs to order spare racks (available only as next-day replacements).

For more information about the R42610 rack, see RACKS on page 50.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

45

OPTIONAL STEP - ORDER PDU

OPTIONAL STEP - ORDER PDU


An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC460 M2 server. This PDU is available in a zero rack unit (RU) style (see Table 27). Table 27 PDU Options PID Description Zero RU PDU

Product ID (PID) RP208-30-2P-U-2

For more information about the PDU, see PDUs on page 52.

46

Cisco UCS C460 M2 High-Performance Rack-Mount Server

SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL
CHASSIS
An internal view of the C460 M2 chassis with the top cover removed is shown in Figure 8. Figure 8 C460 M2 With Top Cover Removed

Cisco UCS C460 M2 High-Performance Rack-Mount Server

47

SUPPLEMENTAL MATERIAL

CPUs and DIMMs


Physical Layout
Each CPU controls four serial memory interface (SMI) channels (see Figure 5 on page 14). There is one memory riser for every two channels. There are therefore two memory risers per CPU. Each CPU channel drives a memory buffer on a riser card, and each memory buffer converts a CPU SMI into two DDR3 subchannels that each read and write two DIMM pairs on a memory riser. The physical layout of a memory riser is shown in Figure 9. Figure 9 Memory Riser Physical Layout

1D 2D 1C 2C 2
199466

2A 1A 2B 1B

Memory buffer #1

Memory buffer #2

In Figure 9, the buffers and channels are:


Buffer 1, subchannel 1: slots 1B and 1D Buffer 1, subchannel 2: slots 1A and 1C Buffer 2, subchannel 1: slots 2B and 2D Buffer 2, subchannel 2: slots 2A and 2C

Memory Population Rules


When considering the memory configuration of your server, you should observe the following:

The minimum configuration for the server is at least one matched DIMM pair installed in a memory riser on either CPU1 or CPU2 All four CPUs can run from a single DIMM pair. DIMMs are required to be populated in pairs. DIMMs for this server are configured as two-DIMM kits.

48

Cisco UCS C460 M2 High-Performance Rack-Mount Server

SUPPLEMENTAL MATERIAL

The DIMMs in any given pair must be identical. Any DIMM installed in a memory riser corresponding to an empty CPU slot becomes inaccessible. For optimal performance, distribute DIMMs evenly across all installed CPUs and memory buffers. DIMMs within a subchannel are populated starting with the DIMMs farthest from the memory buffer in a fill-farthest approach. For example, the order that you should populate the four channels on a memory riser is as follows (see also Figure 9 on page 48): 1.Slots 1B and 1D (buffer 1, subchannel 1) 2.Slots 1A and 1C (buffer 1, subchannel 2) 3.Slots 2B and 2D (buffer 2, subchannel 1) 4.Slots 2A and 2C (buffer 2, subchannel 2

Cisco UCS C460 M2 High-Performance Rack-Mount Server

49

SUPPLEMENTAL MATERIAL

RACKS
The Cisco R42610 rack (see Figure 10) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment:

Cisco UCS B-Series servers and fabric interconnects Cisco UCS C-Series and select Nexus switches

The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are listed in Table 28. Table 28 Cisco R42610 Rack Specifications Parameter Dimensions (H x W x D) Dimensions (H x W x D) with packaging Distance from front mounting rail to rear mounting rail Weight Weight with packaging Side panels included Equipment mounting capacity Static load capacity Dynamic load capacity Standard Rack 78.74 x 24 x 43.38 in. (2000 x 610 x 1102 mm) 89 x 33 x 47 in. (2261 x 838 x 1194 mm) 29.2 in. (741 mm) Expansion Rack 78.74 x 23.58 x 43.38 in. (2000 x 599 x 1102 mm) 89 x 33 x 47 in. (2261 x 838 x 1194 mm) 29.2 in. (741 mm)

299.83 lb (136 kg) 354 lb (161 kg) Yes 42RU 2100 lb (954 kg) Not applicable

231. 49 lb (105 kg) 284 lb (129 kg) No 42RU 2100 lb (954 kg) Not applicable

NOTE: The AC input connector is an IEC 320 C-14 15 A/250 VAC power inlet.

50

Cisco UCS C460 M2 High-Performance Rack-Mount Server

SUPPLEMENTAL MATERIAL

Figure 10

Cisco R42610 Rack

Front view - door closed

Front view - door open

Front view - door removed

Cisco UCS C460 M2 High-Performance Rack-Mount Server

51

SUPPLEMENTAL MATERIAL

PDUs
Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection. Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician. With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one. The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords. The C-series severs accept the zero-rack-unit (0RU) PDU. See Figure 11). Figure 11 Zero Rack Unit PDU (PID = RP208-30-2P-U-2)

1 2

Breakers Ground connection

3 4

C19 plugs C13 plugs

Cisco RP Series PDU models provide two 20-ampere (A) circuit breakers for groups of receptacles. The effects of a tripped circuit are limited to a receptacle group. Simply press a button to reset that circuit.

52

Cisco UCS C460 M2 High-Performance Rack-Mount Server

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS
Dimensions and Weight
Table 29 UCS C460 M2 Dimensions and Weight1 Parameter Height Width Depth Front Clearance Side Clearance Rear Clearance Weight (maximum configuration, including slide rail brackets and cable management arm)
Notes . . .

Value 6.8 in. (174 mm) 16.7 in.(424 mm) 27.7 in. (704 mm) 3 in. (7.62 cm) 1 in. (25.4 mm) 6 in. (152.4 mm) 110.23 lbs (50 kg)*

1. The system weight given here is an estimate for a fully configured system and will vary depending on the number of peripheral devices and power supplies.

Power Specifications
The general power specifications for the C460 M2 server are listed in Table 30. Table 30 UCS C460 M2 Power Specifications Description AC input voltage AC input frequency Maximum AC input current Maximum AC inrush current Maximum output power for each power supply Power supply output voltage Power supply efficiency Specification 100 to 127 VAC nominal (Range: 90 to 264 VAC) 50 to 60 Hz nominal (Range: 47 to 63 Hz) 9 A at 100 VAC 30 A peak sub-cycle duration 850 W Main power: 12 VDC Standby Power: 5 VDC 92% Peak, complies with 80Plus Gold Standard

NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.

Cisco UCS C460 M2 High-Performance Rack-Mount Server

53

TECHNICAL SPECIFICATIONS

Environmental Specifications
The power specifications for the C460 M2 server are listed in Table 31. Table 31 UCS C460 M2 Environmental Specifications Parameter Temperature operating Temperature nonoperating Altitude Humidity nonoperating Minimum 10C to 35C (50F to 95F) -40C to 70C (-40F to 158F) -30 m to 1500 m (-100 ft to 5000 ft) 95%, noncondensing at temperatures of 25C (77F) to 30C (86F)

Compliance Requirements
The regulatory compliance requirements for C-Series servers are listed in Table 32. Table 32 UCS C-Series Regulatory Compliance Requirements Parameter Regulatory Compliance Safety Description Products should comply with CE Markings per directives 2004/108/EC and 2006/95/EC UL 60950-1 Second Edition CAN/CSA-C22.2 No. 60950-1 Second Edition EN 60950-1 Second Edition IEC 60950-1 Second Edition AS/NZS 60950-1 GB4943 2001 47CFR Part 15 (CFR 47) Class A AS/NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000-3-2 EN61000-3-3 KN22 Class A CNS13438 Class A EN55024 CISPR24 EN300386 KN24

EMC - Emissions

EMC - Immunity

54

Cisco UCS C460 M2 High-Performance Rack-Mount Server

TECHNICAL SPECIFICATIONS

Cisco UCS C460 M2 High-Performance Rack-Mount Server

55

TECHNICAL SPECIFICATIONS

56

Cisco UCS C460 M2 High-Performance Rack-Mount Server

Das könnte Ihnen auch gefallen