Sie sind auf Seite 1von 3

GSM850M Band Selective Tower Mounted Booster

TB-8100
Features
High downlink power of 46dBm to extend cell coverage. MCPA with 20MHz Instantaneous Bandwidth can support multiple continuous GSM Downlink carriers. Supports EDGE. Low noise amplifier reduces uplink system noise figure and helps to reduce call drop and improve voice quality. Reduces handset output power and improved BTS uplink receiver sensitivity. Permits local or remote monitoring via PC or wireless modem. Alarms can be transmitted to OMC via data link or SMS. External alarm to BTS by voltage-free relay contacts. Automatic RF by-pass feature permits BTS operation when equipment or power supply fails. Internal Li-ion backup battery ensures alarm messages are transmitted when equipment or power supply fails. Designed for all outdoor application waterproof, damp-proof and omni-sealed (IP65).

Product Description
The TB-8100 GSM850M band-selective tower mounted booster provides both uplink and downlink amplification. The unit is installed near the antenna at the tower top to boost the transmitted power to extend cell coverage. The uplink low-noise amplifier (LNA) serves to improve the receiver sensitivity of the BTS to cope with the extended cell coverage in the downlink. The unit is powered by various power supply options, including 220VAC, -48VDC, +24VDC. It consists of duplexers (DPX), uplink LNA, downlink MCPA, RF by-pass switch, main Control Unit (MCU), distribution board, power supply unit (PSU), surge protector, wireless modem and Li-ion backup battery. Parameter settings can be done locally via a PC with installed OMT software, or remotely via wireless modem using OMT or OMC software. Alarms are displayed on the OMT screen and can be detected by BTS as external alarm. Through the wireless modem, the alarm data can be transmitted to the OMC automatically, or be sent as SMS to a predefined cellular device.

Functional Block Diagram


Downlink By-pass

MCPA
Tx1 Rx1

Service Antenna 1 Ant1

B T S

BTS1
LNA1
Uplink By-pass

Service Antenna 2

Rx1 Diversity

LNA2
Uplink By-pass

BTS2

Ant2

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued:26Oct09 Control: 0-0-1 1/3

GSM850M Band Selective Tower Mounted Booster


TB-8100
Technical Specifications Electrical
Frequency Range, Uplink Frequency Range, Downlink Instantaneous Bandwidth within Defined TX Band Total Output Power Maximum Uplink Gain Maximum Downlink Gain Gain Adjustment Range (1dB Step), Uplink Gain Adjustment Range (1dB Step), Downlink 9kHz to 1GHz Spurious 1GHz to 12.75GHz Downlink Intermodulation Uplink Noise Figure Pass Band Ripple, p-p Insertion Loss, By-pass Mode Absolute Maximum RF Uplink Input Power Downlink Input VSWR System Group Delay Impedance Dimensions, H x W x D Weight (approx.) Power Supply Options Power Consumption (approx.) Power Up Waiting Time (approx.) MCU Battery Backup Time (approx.) Enclosure Cooling RF Connectors Operating Temperature Operating Humidity EMC Environmental Class MTBF MHz MHz MHz dBm dB dB dB dB dBm dBc dB dB dB dBm dBm nsec mm kg VAC VDC W sec hr 829 849 874 894 20 46 1 16 1 18 1 0 - 16 0 18 -36 / 100KHz -30 / 1MHz 55 1.8 2.0 1.0 +10 +43 1.5 500 50 734 x 397 x 279 37 90 264 / 47 63Hz +24 or -48 450 60 3 Convection N-F or 7/16 DIN-F -40 to +55 95 ETSI EN 301 489-1 IP65 > 50,000 Note: Typical specification at room temperature

Power, Mechanical & Environmental

C %

hr

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued:26Oct09 Control: 0-0-1 2/3

GSM850M Band Selective Tower Mounted Booster


TB-8100
Operation and Maintenance
Using a direct serial connection to a PC, installation and commissioning of the TB-8100 is accomplished by the OMT. Using the integrated wireless modem (data or SMS mode), equipment parameters can be monitored and controlled remotely. Controlled equipment parameters include: ATT, Soft ON/OFF, Over-Temp Threshold, DL Output Power Threshold, DL Input Power Threshold and Alarm Report Enable. Monitored equipment alarms and parameters include: Alarms (LNA, DL PA, Power Down, PSU Fault, Door Open, DL Input Power Low, DL Output Power Low, Over Temp, Input VSWR), UL/DL Gain and DL Input /Output Power. The TB-8100 has been developed to take advantage of advanced network operation, where the OMC (optional) provides effective solution for central monitoring of a group of Comba products.

Outline Drawing

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued:26Oct09 Control: 0-0-1 3/3