Reliability 2.0 Conference RCA Symposium 2010 April 20 - 22 Fort Lauderdale, Florida
TableofContents
BermudaandBELCO MaintenanceStrategyDevelopment RootCause(s) C ( )Philosophy hil h DefectEliminationTriggers TypicalCaseWorkflow RCAinPractice Conclusion
TheislandofBermuda
KeyinformationfromtheCIAWorldFactbook
Population: Totalarea: Highestpoint: Economicoverview: Electricity yuse: 67,837(July ( 2009estimate) ) 54km2 (13000acre) TownHillat76m(250ft) Bermudaenjoysthethirdhighestpercapita incomeintheworld. 628.3millionkWh
BermudaElectricLightCompany
MissionStatement
Toprovideasecure,reliableandsustainable electricpowersystemforthepeopleofBermuda
MajorAssets
Gasturbines(Peaking)
Unit GT3E GT3F GT4 GT5 OEM ALLISON ALLISON SOLAR ABB Type 501KB 501KB JUPITER GT35 Year installed 1995 1995 1989 1995 Rating (kW) ( ) 2,500 2,500 15,000 15,000 Speed (RPM) ( ) 1,200 1,200 3,600 3,600
BermudaElectricLightCompany
DieselEngines(baseload)
Unit D3 D8 D10 D14 D15 E1 E2 E3 E4 E5 E6 E7 E8 OEM Sulzer(Wrtsil) Sulzer(Wrtsil) Sulzer(Wrtsil) FairbanksMorse FairbanksMorse B&W(MANDiesel) B&W(MANDiesel) Sulzer (Wrtsil) (Wrtsil) ) Sulzer( MANDiesel MANDiesel MANDiesel MANDiesel Type ZV40/48 ZV40/48 ZV40/48 PC2V PC2V 8K67GSCA 8K67GSCA ZAV40S ZAV40S 48/60A 48/60A 48/60B 48/60B Year installed 1982 1979 1980 1995 1995 1984 1985 1989 1989 2000 2000 2005 2005 Rating Speed (kW) (RPM) 8,000 8,000 8,000 5,525 5 525 5,525 12,493 12,493 10,500 10,500 , 14,300 14,300 14,300 14,300 514 514 514 514 514 150 150 514 514 514 514 514 514 Stroke Cylinders 4 4 4 4 4 2 2 4 4 4 4 4 4 16 16 16 16 16 8 8 16 16 14 14 14 14
MaintenanceStrategyDevelopment ResultstoDate
CorrectiveWork
RootCause(s)Philosophy
Therearemany yRCAapproaches pp Thesignaturefeaturesembeddedinourchoiceare
Goalcentered CauseandEffect Visual Problem,Analysis,Solutionsteps Alwayslookatmultiplecauses Currentprocessisperfectforcurrentresults!
AgreedsolutionsbecomepartofMaintenance/Business Strategy
DefectEliminationTriggers2010
E1/2 JCWLeak C linderHeadLeak Cylinder ExhaustTemperature ExhaustBellows ExhaustValve Exhaust austLeak ea FuelLeaks BlowDownPipe Injectorissues E5/6 JCWIngresstoCyl CACooler Fuelsystemleaks SplashOil RockerGear LubeOilCooler FuelPump FuelRailClamps p Nutshelllines E3/4 Linerissues MainTransformer HTCWpressure FuelLeaks EngineDrivenLOPump Protective otect eRelay e ayTrip p Governor Nutshelllines EngineDrivenFOPump E7/8 BrokenHeadStud CylWaterLeak FuelPumps Nutshellpipe FuelInjector LubeOilPressure Transformertaps CACooler LubeOilSuctionFilter
TypicalCaseWorkFlow
ForcedOutage g onDElist FirstResponse/Oncallfitterfilloutbasicform/map REinvestigatesandaddsdetailassistedby
Fitter Foreman Engineer Planner Operator Buyer
RCAinPractice
CauseMapping SolutionsProvided
FuelPumpSupplyPipeFailure ChargeAirCooler(CAC)TubeLeaks FuelPumpDriveDamage
DetailedCauseMap
TurbochargerFailure
CauseMapping
Startwiththeimpactoncompanygoals
SafetyGoal Impacted Availability GoalImpacted Materialand LaborGoal Impacted
Whatcausedit?
Solution Effect Cause
Fire
Evidence
AND
Continuetodigdeeper
Oxygen
E5FuelPumpSupplyPipeFailure
CauseMap
SafetyGoal Potentially Impacted d Unplanned emergency work required Cyclicload Availability Goal Impacted Engine unavailable for16 hours Forced outage g to repaira fuelleak Failureofa FOsupply pipeonthe engine Fatigue crackingof thesupply pipe Fracture surfaceand agradual failure mechanism Severeoil spillage AND Physical inspectionof allbrackets. Vibration Vibration Alargediesel engine. AND Ineffective pipesupport Poor conditionof thebrackets Alargediesel engine.
AND QC check sheets for PMto t inspectall brackets. Ineffective maintenance Outstanding workrequest andPMto inspect(4 timesinthe 15months).
Prolonged g exposure
CheckSheet BracketInspection
E8CACTubeLeak
CauseMap
SafetyGoal Potentially Impacted Metal ? Improve accessto procedure. QC new checksheet. Oxygen concentration cell Permissible ChloridesinCW <50ppm AND ActualChlorides inCW> 50ppm Tubesarenot brushed d i during refurbishment Observed during overhaul. NewRO plant. Chlorides in makeupwater >50ppm AND Forcedoutage toreplacea leakingCAC AND Material land d LaborGoal Impacted Morefrequent f CAC refurbishment Inadequate information availabletothe Fitter AND Supplierunable toprovide correctspares OEMspares referencesonly theentire assembly
Excessivetube corrosion i
Electronflow
AND
ElectronicSparesManual
DamagetoFuelOilPumpDrive
CauseMap
Thedesign ofthefuel pump p p Safety Goal Potentially Impacted Unplanned emergency work required Existing problems withFO pumps Various sources (known problem) Availability Goal Impacted RTS delayedby 7hours Pumpdrive was damaged OR Destructive test done withlow viscosity MDO. Specificto the inspection ofthedrive Actual:well below 12cSt Online viscosity measure ment and trending. Cavitation damageto pump elements OEM designnew pump elements. AND LowFO viscosity ? Permissible operating condition: 1214cSt Design inputFO: 120cSt(at 50C) Modifythe FOsupply systemto allowfor cooling. Systemis unableto reduceFO temp. Original power plantspec.
AND
AND
TurbochargerFailure
CauseMap TurbochargerFailure
SafetyGoal I Impacted t d IncreasedRisk t Staff to St ff Onlinetip clearance monitor Onlinevibration Increase periodicvibration readings trendRPMon DCS oiltemp monitoring
ProductionGoal Impacted
Availability Target
Materials& Labourbudget
CauseMap TurbochargerFailure
BladeFouling OR nonstickcoated rings Nozzlering fouling OR
Airflow turbineside
Casingfouling
CauseMap TurbochargerFailure
upgradetononstick coatedblades Particulate buildupon blades Particulate buildup operationsforeman toformallyverifythis isdone educateoperations onimportanceofthis work
CauseMap TurbochargerFailure
Amountin
AND
Redesigna systemthat doesntusedCA Compressed Airused Nushellsclump together observation Compressed AirQuality AND Designrequires compressedair
Amountout
CauseMap TurbochargerFailure
ReviewMaintenance Strategy,failure modes PM effectiveness AutoDrainnot performing
Comp.Air BottleDrainage
ServiceInterval
Design
CauseMap TurbochargerFailure
Installpilotline ReviewSpecification Procedures
Design
Willnotdryair sufficiently
Pilotline missing
Pilotlinenever installed
CauseMap TurbochargerFailure
Summary