Catalogue
03/10
CDB Engineering reserve the right to carry out any necessary modification without prior notice
C D B Engineering
S.p.A.
Production program
Simplex Basket filters Duplex Basket filters
Cartridge filters
fabricated Y strainers
CDB Engineering reserve the right to carry out any necessary modification without prior notice
C D B Engineering
S.p.A.
Conical strainers
Flat strainers
filtering elements
Steam Separators
Exhaust head
Flame Arrestor
Spectacle flanges
Sample coolers
Sight glasses
CDB Engineering reserve the right to carry out any necessary modification without prior notice
C D B Engineering
SKID PACKAGES & ANALYZER PACKAGES
S.p.A.
CDB Engineering provides design, engineering, construction and project management for various skid units systems. The following is a short list of CDB production: Gas Fiscal metering Hydrogen Production Skid Analyzer Packages Analyzer Shelters Liquid Fiscal metering Ultra-filtration Package Sampling Systems Gas Reduction Station Water injection for Turbines Laboratory Sampling panels Gas filtration Gas Oil Injection for Turbines Feasibility study Detailed design, Supply Gas Heaters specification and MR, Data Sheets Gas injection modules Chemical Injection Nitrogen production .
CDB Engineering reserve the right to carry out any necessary modification without prior notice
C D B Engineering
S.p.A.
CDB ENGINEERING was founded in 2000. The aim of the company is to supply quality products and services for the improvement of technical installations. With this goal in mind, research and development is continuously being carried out for the benefit of our customers. Thanks to qualified engineers, updated production and testing facilities, we have specialized ever since our foundation in supplying equipment along with the necessary know how and expertise for filtration and process engineering solutions. The material range in addition to the standard pieces in carbon steel includes stainless steel, non ferrous and exotic alloys, Duplex, 6MO and Titanium.
Our current manufacturing facilities are built over an area of 25000 square meters; We would, of course, always be delighted to welcome you at our head offices and factory at which time we would make the most of your visit and introduce you to our members of staff. We can assure you that you would have no hesitations about the reputation and ability of CDB ENGINEERING after such a visit.
CDB Engineering quality management system is certified according to Our quality assurance department ensures that our quality procedures are followed and improved throughout the complete manufacturing process cycle. Welders and Welding Procedures are certified by T..V.
ISO 9001:2008
PED 97/23/EC
ATEX 94/9/EC
ASME U STAMP
CDB Engineering reserve the right to carry out any necessary modification without prior notice
C D B Engineering
S.p.A.
STEAM PRODUCTS
Thermodynamic Steam Traps
Aside from the orifice trap this is probably the simplest trap on the market and yet is the most widely used. The disc trap is made up of three primary components: the body, the cap and the disc. Like the orifice trap, the operation of the disc trap utilizes the difference in specific volume between steam and condensate. With flow moving through a fixed orifice this translates into a difference in velocity between steam and condensate. Operation of the disc trap also utilizes flash steam as an operating force to work in conjunction with the velocity of the steam. In order to understand the operation of the disc itself we have to know the principle under which it operates. Bernoulli's Principle, simply stated: THE PRESSURE OF A FLUID (LIQUID OR GAS) DECREASES AT POINTS WHERE THE SPEED OF THE FLUID INCREASES. Applying this to the disc trap we are, in fact, creating a low pressure zone between the disc and seats whenever we increase the velocity of the steam or condensate flowing through this zone. In addition we are providing a small chamber for the accumulation of flash steam above the disc. Fig. shows a simple disc trap. As flow, in the form of condensate, moves into the trap and through the inlet orifice it forces the disc to lift, allowing the condensate to pass through and out the outlet. As the temperature of the condensate reaches it's saturation point a percentage of that condensate will flash as it exits the inlet orifice. When steam reaches the inlet orifice two things will immediately happen: the velocity will increase sufficiently to create a low pressure zone between disc and seats pulling the disc down upon the seats. At the same time flash steam will have formed behind the disc and, with the exit orifice sealed off, the pressure induced by this non-escaping flash steam will hold the disc in place. The disc will remain in place until the flash steam has condensed, thus allowing the disc to open again. Size to 2 rating 600# to 2500#
Balanced Pressure
The Balanced Pressure type trap operates on the principal of liquid expansion due to an increase in temperature. The liquid is contained in a bellows internal to the steam trap and fixed at one end. Integral to the bellows is a valve attached to its free end. The liquid in the partially filled bellows can be as simple as distilled water under vacuum or an alcohol combination to reduce its vapor point to a lower degree than water. At ambient conditions the bellows is contracted with the valve away from the seat. When steam, or condensate near it's saturation point, comes in contact with the bellows the liquid inside the bellows expands and drives the valve into the seat closing off steam flow. As the steam condenses, collects and cools, the bellows will cool and contract, backing the valve away from the seat and allowing the accumulated condensate to pass. As the condensate passes through the trap and is replaced by steam the bellows heats up again. As steam comes in contact with the bellows it expands and closes the valve, shutting off flow. As you can see this trap is not governed not only by the pressure differential but rather by the temperature of the steam and condensate. Size to 2 rating up to 300#
CDB Engineering reserve the right to carry out any necessary modification without prior notice
C D B Engineering
S.p.A.
With the improvement of the simulation systems it is now possible to attend with great precision to the design of mechanical part and fluid systems The FEM conducts a series of computational procedures involving applied forces, and the properties of the elements which produce a model solution. Such a structural analysis allows the determination of effects such as deformations, strains, and stresses which are caused by applied structural loads such as force, pressure and gravity.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
C D B Engineering
S.p.A.
POS.
1 2 3 4 5 6 7 8 9 10 11 * optional
DESCR.
Body Cover Gasket Studs Nuts Screen Perf. Plate Mesh Drain Vent Lifting eyes Legs Davit*
MAT.
C.S.. A105N SW A193B7 A194 2H SS304 SS304 SS304 A105N A105N C.S. C.S. C.S.
spare
X x
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
DESCR.
Body Cover Gasket Studs Nuts Screen Drain Vent Lifting eyes Legs Davit* * optional
MAT.
C.S.. A105N SW A193B7 A194 2H SS316L A105N A105N C.S. C.S. C.S.
spare
X x
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
DESCR.
Body Cover Gasket Studs Nuts Screen Drain Vent Lifting eyes Legs Davit* * optional
MAT.
C.S.. A105N SW A193B7 A194 2H SS316L A105N A105N C.S. C.S. C.S.
spare
X x
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS.
1 2 3 4 5 6
DESCR.
Body Cover Gasket bolting screen Drain/Vent
MAT.
C.S.. A105N SW A193B7/ A194 2H ss A105N
spar e
X X
260 400 20
280 400 21
1 300 400 23
1. 410 500 25
2 420 550 27
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS. 1 2 3 4 5 6 7
Std MAT. ASTM A216wcb Ss 304 Sw 316/graphite Astm a105n Astm a193b7 Astm a1942h Astm a105n
Std Mat. ASTM A351 cf8(m) Ss 304-316 Sw 316/graphite Astm a182 f304/316 Astm a193 b8 Astm a194 Gr8 Astm a182 f316
Std mat. ASTM A352lcb Ss304 Sw316/graph ASTM A350lcb L7 Gr4 Astm a105n
SPARE X x
CONNECTIONS
Flanged
Asme b16.5
Size (inches) 2 3 4 6 8 10 12 14 16
ANSI 150#
ANSI 300#
All strainers should be installed as close as possible to the machinery which they are being installed to protect. It is important to ensure that the strainer installed with the flow following the same direction as the flow direction arrow cast onto the strainer body. For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline. strainers should never be installed in vertical pipelines in the upward flow condition.
CDB engineering
C D B Engineering
S.p.A.
OPTIONAL
UP TO 4
4 AND ABOVE
Size (inches) 1. 2 3 4 6 8
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
DESCR.
Body Cover Gasket Studs Nuts Screen Perf. Plate Mesh Drain Vent Lifting eyes Legs Davit* Butterfly valves Tee flanges *optional CONNECTIONS Buttweld Flanged
MAT.
C.S.. A105N SW A193B7 A194 2H SS304 SS304 SS304 A105N A105N C.S. C.S. C.S. C.S. A234wpb A105n
spare
X x
Size A B C D E F Kg
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
DESCR.
Body Cover Gasket Studs Nuts Screen Perf. Plate Mesh Drain Vent Lifting eyes Legs Davit* valves
MAT.
C.S.. A105N SW A193B7 A194 2H SS304 SS304 SS304 A105N A105N C.S. C.S. C.S. C.S.
spare
X x
*optional
Size A B C D E F Kg
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
DESCR.
Body Cover Gasket Studs Nuts cartridges Drain Legs Fluid water
MAT.
A106/ss304 A105N/F304 SW 304/graph. A193B7/b8 A194 2H/Gr8 SS304/ppe/exc. A105N/f304 C.S.
Included in the supply: box control-pneumatic actuated drain valve differential pressure switch motor electrical equipment ip55 Flow rate and dimensions to be considered applicable until 250 Available ratio: 20-35-50-75-100-125-150-175-200-225-2502000 Max available flow 10000 m3/h
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
DESCR.
Body Cover Gasket Studs Nuts Screen Drain Vent Lifting eyes Legs Davit* * optional
MAT.
C.S.. A105N SW A193B7 A194 2H SS/ P.P. A105N A105N C.S. C.S. C.S.
spare
X x
FBCH
FBCV
please visit our web site www.cdbengineering.com
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
DESCR.
Body Cover Gasket Studs Nuts Screen Drain Vent Lifting eyes Legs Davit* * optional
MAT.
C.S../S.S. CS/SS SW A193B7 A194 2H SS/ P.P. CS/SS CS/SS C.S. C.S. C.S.
spare
X x
FBHL
FBHX
F.E.M. ANALYZED
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
DESCR.
Body Cover Gasket Studs Nuts Screen Drain Vent Lifting eyes Legs Davit* * optional CONNECTIONS Buttweld Flanged
MAT.
C.S.. A105N SW A193B7 A194 2H SS/ P.P. A105N A105N C.S. C.S. C.S.
spare
X x
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
T TYPE STRAINERS
CDB engineering - TEE TYPE STRAINER ARE CUSTOM ENGINEERED AND DESIGNED TO SUITE THE REQUIRED INSTALLATION AND PERFORMANCE. ALL THE TYPE OF DESIGNS HERE BELOW HAVE BE DEVELOPED BY OUR ENGINEERS WHO ARE FULLY COMMITED TO IMPROVE OUR PRTODUCTS FEATURES TROUGH OUR CONTINUOS RESEARCH TESTING ACTIVITY AND
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS. 1 2 3 4 5 6 7 8 9 10
* optional
DESCR. Body Flange Cover Basket Guide rods gasket Bolting drain Hinge* Davit*
SPARE
X X
FTS
FT2V
FTX
Size 2 L 127 L1 254 H 148 H1 = H x 2 L 127 L1 268 H 158 H1 = H x 2 L 127 L1 286 H 177 3 172 312 182 172 332 197 172 351 216 4 210 363 208 210 382 225 210 427 260 6 286 464 260 286 483 281 286 535 324 8 356 560 311 356 579 333 356 636 382 10 432 636 351 432 668 385 432 750 447 12 508 737 403 508 769 438 508 833 492 16 610 864 472 610 903 511 610 979 574 RATING 150# 20 24 762 864 1052 1169 571 635 RATING 300# 686 762 864 1004 1086 1201 565 609 673 RATING 600# 686 762 864 1067 1156 1284 624 676 753 18 686 966 525 26 990 1172 586 990 1283 642 990 1356 678 28 1042 1236 618 1042 1345 672 1042 1427 714 30 1118 1322 661 1118 1438 719 1118 1531 766 32 1194 1414 707 1194 1534 767 1194 1630 815 34 1270 1494 747 1270 1620 810 1270 1541 770
FT3V
36 1346 1585 792 1346 1712 856 1346 1836 918 38 1422 1674 837 1422 1810 905 1422 1788 894 40 1498 1759 880 1498 1900 1071 1498 2043 1195
Maintenance Strainer maintenance should be made at least once year, or whenever the pressure drop is found to be in excess of the normal figures. A quick clean-up system, to made approximately once a mounth. For a complete maintenance follow the points herebelow: -1- Be sure that the main line has been shut-off. -2- Untighten cover stud bolts and nuts, remove cover and gasket . -3- Withdraw basket and carefully inspect it for damages. If any hole in the screen is found abstructed, then clean it . If the basket is broken in any part or out of shape, replace it with a new spare one. -4- Carefully clean the inside of the strainer body. -5- Fit a new gasket . -6- Install the new screen or the cleaned one . -7- Put in place cover . -8- Slowly give pressure to the line, checking for leakages. -9- Write on the strainer body the date of this maintenance operation.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS. 1 2 3 4 5 6 7 8 9 10
* optional
DESCR. Body Flange Cover Basket Guide rods gasket Bolting drain Hinge* Davit*
SPARE
X X
FTS
FT2V
RATING 900# 10 12 16 432 508 610 813 922 1056 485 549 626 RATING 1500# 10 12 16 432 508 610 953 1087 1256 625 714 816
FTX
FT3V
Maintenance Strainer maintenance should be made at least once year, or whenever the pressure drop is found to be in excess of the normal figures. A quick clean-up system, to made approximately once a mounth. For a complete maintenance follow the points herebelow: -1- Be sure that the main line has been shut-off. -2- Untighten cover stud bolts and nuts, remove cover and gasket . -3- Withdraw basket and carefully inspect it for damages. If any hole in the screen is found abstructed, then clean it . If the basket is broken in any part or out of shape, replace it with a new spare one. -4- Carefully clean the inside of the strainer body. -5- Fit a new gasket . -6- Install the new screen or the cleaned one . -7- Put in place cover . -8- Slowly give pressure to the line, checking for leakages. -9- Write on the strainer body the date of this maintenance operation.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
* optional
Maintenance Strainer maintenance should be made at least once year, or whenever the pressure drop is found to be in excess of the normal figures. A quick clean-up system, to made approximately once a mounth. For a complete maintenance follow the points herebelow: -1- Be sure that the main line has been shut-off. -2- Untighten cover stud bolts and nuts, remove cover and gasket . -3- Withdraw basket and carefully inspect it for damages. If any hole in the screen is found abstructed, then clean it . If the basket is broken in any part or out of shape, replace it with a new spare one. -4- Carefully clean the inside of the strainer body. -5- Fit a new gasket . -6- Install the new screen or the cleaned one . -7- Put in place cover . -8- Slowly give pressure to the line, checking for leakages. -9- Write on the strainer body the date of this maintenance operation.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS.
DESCR.
MAT.
C.S.. A105N Ss 304 c.s. Sw 304/graph. A105n B7/2h c.s. c.s.
MAT.
SS 304 or 316 F304/F316 Ss 304 /316 SS Sw 316/graph. F316 B8/Gr8 c.s. c.s.
spare
1 Body 2 Cover 3 screen 4 ring 5 gasket 6 drain 7 bolting 8 Hinge* 9 handle * optional
X x
Size (inches) 1 1. 2 3 4 6 8 10 12 14 16 18 20 24
ANSI 150# H H1
Kg
ANSI 300# H H1
Kg
l-rtj
ANSI 600# H H1
Kg
l-rtj
ANSI 900# H H1
Kg
203 241 292 406 495 622 699 787 914 978 978 1295
200 250 315 410 495 600 700 800 850 955 1110 1180
370 350 450 615 725 875 800 1175 1300 1400 1700 1750
267 318 356 445 559 622 711 838 914 978 1016 1346
215 270 335 380 555 650 740 805 920 1025 1140 1360
370 360 465 470 740 950 1100 1200 1350 1400 1700 2050
292 356 432 559 660 787 838 889 991 1092 1194 1397
295 359 435 562 663 790 841 892 994 1095 1197 1400
225 290 370 550 610 750 720 865 1180 1300 1420 1660
370 390 495 730 805 1100 1200 1420 1520 1650 1820 2120
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS.
1 2 3 4 5 6 7
DESCR.
Body Cover screen Lifting lug gasket drain bolting
MAT.
A106 b A105N Ss 304 c.s. Sw 304/graph. A105n B7/2h
MAT.
316 F316 Ss316 Ss Sw 316/graph F316 B8/Gr8
spare
X x
Size
2 3 4 6 8 10 12 14 16
A
290 380 420 520 610 740 820 880 980
B
110 140 150 180 210 260 280 290 330
C
210 260 300 400 500 600 700 750 850
F
500 560 590 770 970 1170 1370 1470 1660
CONNECTIONS Buttweld
ANSI B16.25
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS. 1 2 3 4 5 6 7
Std MAT. ASTM A216wcb Ss 304 Sw 316/graphite Astm a105n Astm a193b7 Astm a1942h Astm a105n
Std Mat. ASTM A351 cf8m Ss 316 Sw 316/graphite Astm a182 f316 Astm a193 b8 Astm a194 Gr8 Astm a182 f316
SPARE X x
CONNECTIONS Buttweld Flanged Size (inches) 1 1. 2 2. 3 4 6 8 10 12 14 16 18 20 24 l 169 172 197 219 203 216 241 292 406 495 622 699 788 914 978 978 1295
FYC150 ANSI 150#
H 135 135 150 185 210 220 255 295 395 485 600 700 770 910 1030 1095 1310
H1 170 170 195 245 300 250 355 420 570 700 900 1060 1200 1385 1600 1750 2030
Kg 9,5 10,5 12 14 20 26 39 70 133 218 340 350 640 700 895 1370
l 175 178 203 229 267 318 356 445 559 622 711 838 864 978 1016 1346
H 140 140 160 185 215 260 315 440 485 635 730 805 920 1025 1140 1380
H1 170 170 195 245 300 365 437 625 675 930 1075 1200 1350 1400 1700 2095
l 188 191 216 241 292 356 432 559 660 787 838 889 991
lrTJ 188 191 216 241 295 359 435 562 663 790 841 892 994
H 140 140 160 185 230 300 360 485 575 705 720 865 1180
H1 170 170 195 245 310 390 480 670 780 990 1200 1420 1520
All strainers should be installed as close as possible to the machinery which they are being installed to protect. It is important to ensure that the strainer installed with the flow following the same direction as the flow direction arrow cast onto the strainer body. For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline. Y strainers should never be installed in vertical pipelines in the upward flow condition.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS. 1 2 3 4 5 6 7
MAT. ASTM A216wcb Ss 304 Sw 316/graphite Astm a105n Astm a193b7 Astm a1942h Astm a105n
Mat. ASTM A351 cf8m Ss 316 Sw 316/graphite Astm a182 f316 Astm a193 b8 Astm a194 Gr8 Astm a182 f316
SPARE X x
CONNECTIONS Buttweld Flanged Size (inches) 1 1. 2 3 4 6 8 10 12 14 16 18 20 24 l 264 273 308 305 368 381 457 610 737 838 965 1029 1130 FYC900 900# lrTJ H 165 175 180 230 371 250 384 350 460 430 613 510 740 650 841 765 968 892 1038 895 1140 960
Asme B16.25 Asme b16.5 FYC1500 1500# lrTJ H 165 175 254 210 305 250 371 320 473 360 546 390 711 575 842 730 FYC2500 2500# lrTJ H 165 175 308 215 387 285 454 340 360 400 410 620
H1 250 255 270 340 400 475 570 670 885 1070 1250 1300 1400
All strainers should be installed as close as possible to the machinery which they are being installed to protect. It is important to ensure that the strainer installed with the flow following the same direction as the flow direction arrow cast onto the strainer body. For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline. Y strainers should never be installed in vertical pipelines in the upward flow condition.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
X X
Size (inches) 2 3 4 6 8 10 12 14 16 18 20 24
lrTJ
1500# H
H1
L RF
2500# lrTJ H
H1
All strainers should be installed as close as possible to the machinery which they are being installed to protect. It is important to ensure that the strainer installed with the flow following the same direction as the flow direction arrow cast onto the strainer body. For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline. Y strainers should never be installed in vertical pipelines in the upward flow condition.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS. 1 2 3 4 5 6 7 8
DESCR. Body cover screen STUD BOLTS NUTS gasket Drain plug flanges
Std MAT. ASTM A105N Astm a105n Ss 304 ASTM A193 B7 ASTM A194 2H Sw 316/graphite Astm a105n Astm a105n
Std Mat. ASTM A182 F316 Astm a182 f316 Ss 316 ASTM A193 B8 ASTM A194 GR8 Sw 316/graphite Astm a182 f316 Astm a182 f316
SPARE
x X
CONNECTIONS Screwed Buttweld Socket Welding Flanged Size (inches) DRAIN PLUG L
ANSI B1.20.1 (NPT) / BS21 (BSP) ANSI B16.25 ANSI B16.11 ANSI / UNI / DIN H H1 Weight (Kg) 1 1 1 3 6 11 UNI-DIN PN16-25-40 L Kg 153 153 166 203 233 2.6 4 4.4 11 13 RF-150# L 178 182 202 243 270 Kg 2.3 3.2 4.2 9.7 12 RF-300# L 187 190 214 256 283 Kg 2.8 4.3 5.3 13 15 L 200 205 227 271 302 RF-600# Kg 3.2 4.7 5.8 15 16.3
3/8 90 60 85 98 99 113 98 99 113 1 111 110 130 1 140 138 162 2 170 168 200 STANDARD PERFORATIONS 0.8mm SPECIAL PERFORATIONS ON REQUEST Dimension : L, H , H1 are in millimeters ( mm)
All strainers should be installed as close as possible to the machinery which they are being installed to protect. It is important to ensure that the strainer installed with the flow following the same direction as the flow direction arrow cast onto the strainer body. For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline. Y strainers should never be installed in vertical pipelines in the upward flow condition.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS. 1 2 3 4 5 6 7 8
DESCR. Body cover screen STUD BOLTS NUTS gasket Drain plug flanges
Std MAT. ASTM A105N Astm a105n Ss 304 ASTM A193 B7 ASTM A194 2H Sw 316/graphite Astm a105n Astm a105n
Std Mat. ASTM A182 F316 Astm a182 f316 Ss 316 ASTM A193 B8 ASTM A194 GR8 Sw 316/graphite Astm a182 f316 Astm a182 f316
SPARE
x X
CONNECTIONS Screwed Buttweld Socket Welding Flanged Size (inches) 3/8 1 1 2 DRAIN PLUG L
ANSI B1.20.1 (NPT) / BS21 (BSP) ANSI B16.25 ANSI B16.11 ANSI b16.5 H H1 RF-1500# L 90 98 98 111 140 170 60 99 99 110 138 168 85 113 113 130 162 200 216 230 250 297 360 Kg 5 6,2 10,6 16,5 33,1
All strainers should be installed as close as possible to the machinery which they are being installed to protect. It is important to ensure that the strainer installed with the flow following the same direction as the flow direction arrow cast onto the strainer body. For mounting in horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline. Y strainers should never be installed in vertical pipelines in the upward flow condition.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
CONICAL STRAINERS FC
Conical type temporary strainers are designed for the efficient removal of solids in new pipeline start up service. They are compact and rugged and can be installed either vertically or horizontally. They can be manufactured using any kind or wire mesh or perforated plate , in carbon and stainless steel or exotic alloys. Given dimensions are for reference purpose only. Strainers may be manufactured to any customers standard. Strainers are designed to be installed between ANSI B16.5 flanges and meet FF , RF and RTJ facings.
POS.
1 2 3
DESCR.
Ring Perf. plate reinforcements
MAT.
C.S.. Ss304 Ss 304
Mat.
Ss 304/316 Ss 304/316 Ss 304/316
Size 1 2 3 4 6 (inches) R 11 10 10 8 8 D 73 92 127 157 216 H 70 70 70 80 100 L (FC1) 300 350 450 460 670 L (FC2/FC3) 140 180 230 260 400 C 20 20 20 20 20 S 3 3 3 3 3 A (SCH STD) 30 40 65 90 140 B 40 40 65 70 95 Dimensions : D , H , L , C , S , A , B are in millimeters ( mm ) OTHER SIZES ON REQUEST
ASSEMBLY INSTRUCTION 1) Insert the strainer between the two flanges 2) Make sure the two gasket are fitted on both sides 3) Tighten bolts , keeping the strainer + gaskets in the correct position MAINTENANCE INSTRUCTIONS Unscrew bolts 1) 2) Remove the strainer and clean or replace it 3) When re-assembling use new gaskets
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
FLAT STRAINERS FF
flat type strainers are designed for the efficient removal of solids in new pipeline start up service. They are compact and rugged and can be installed either vertically or horizontally. They can be manufactured using any kind or wire mesh or perforated plate , in carbon and stainless steel or exotic alloys. Given dimensions are for reference purpose only. Strainers may be manufactured to any customers standard. Strainers are designed to be installed between ANSI B16.5 flanges and meet FF , RF and RTJ facings.
POS.
1 2 3
DESCR.
Ring Screen handle
MAT.
C.S.. Ss304 Ss 304
Mat.
Ss 304 Ss 304 Ss 304
3 1
D A
Size 1 2 3 4 (inches) D 73 92 127 157 L 70 70 70 80 S 3 3 3 3 A 33 48 75 100 Dimensions : D , L , S , A , B are in millimeters ( mm ) OTHER SIZES ON REQUEST
ASSEMBLY INSTRUCTION 1) Insert the strainer between the two flanges 2) Make sure the two gasket are fitted on both sides 3) Tighten bolts , keeping the strainer + gaskets in the correct position MAINTENANCE INSTRUCTIONS Unscrew bolts 1) 2) Remove the strainer and clean or replace it 3) When re-assembling use new gaskets
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS.
Z1
2 3 4 6
DESCR.
BODY FLANGE GLASS GASKET flange
MAT.
A105N A105N ** GRAPHITE A105n
MAT.
F316 F316 ** GRAPHITE F316
spare
X x
TYPE-F-
ANSI B1.20.1 (NPT) / BS21 (BSP) ANSI B16.25 ANSI B16.11 ANSI / UNI / DIN
Flow indicator type: (B)Fixed flappers (f) spinner (D)Floating balls (C)Moving chain
connections
size
S 90 90
H 80 80
D 40 40
1 1 2
90 110 125
50 70 80
How to service: Maintenance of flow indicators should be made whenever the visibility through the window is poor. Follow the points here below: 1) Make sure that the main line is shut-off 2) Loosen bolts and remove covers , glasses and the four gaskets 3) Clean the inside of the body to remove any dirt. 4) Clean the two glasses with a soft cloth using if necessary a suitable cleaning fluid. If glasses are damage or cracked replace them. 5) Reassemble all the elements replacing the four gaskets. 6) Slowly give pressure to the line checking for leaks.
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS.
1 2 3 4 5 6
DESCR.
Body Flanges GLASSES GASKET STUD BOLT NUTS
MAT.
A216 wcb A216 wcb ** GRAPHITE ASTM A193 B7 ASTM A194 2H
MAT.
A351 cf8m A351 cf8m ** GRAPHITE ASTM A193 B8 ASTM A194 Gr.8
spare
X X
TYPE E -
TYPE F -
Flow indicator type: Fixed flappers (B) Spinner (F) Floating balls(D) Moving chain(C)
DRIP TUBE (E)
SIZE 1 1. 1. 2 2. 3 4 6 8 10
130 150 160 180 200 230 290 310 350 480 600 730
C 10 10 10 12 12 15 15 20 25 30 30 30
connections flanged
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS.
1 2 3 4 5 6
DESCR.
flange BODY GLASSES GASKET FLANGE BOLTING
MAT.
A105N A106B TEMPERED GRAPHITE A105n B7/2H
MAT.
SS304/316 SS304/316 TEMPERED GRAPHITE Ss304 B8/Gr8
spare
X X
Flow indicator type: Fixed flappers spinner Floating balls Moving chain
SIZE 2 3 4 6 8 10 12
Thk glasses 12 15 18 20 25 25 30
Kg 15 25 35 80 95 110 140
connections flanged
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
POS.
1 2 3 4 5 6 7 8 9 10 11 12 13
DESCR.
Shell Flange bolts Product inlet Product outlet nuts gasket coil caps drain Over flow Water inlet legs
MAT.
C.S.. A105N A193 b7 Ss304 A106 Grb A194 2h graphite SS304 A234 wpb A106 grb A105n. A105n. C.S.
spare
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
STEAM SEPARATOR SS
CDB engineering fabricated steam separator have been specifically designed to remove moisture from steam and compressed air lines. Designed and fabricated to ASME VIII Div.1 as standard but can also be supplied to other pressure vessel codes. I.e. ASME B31.3 etc. Standard features include carbon steel shell and baffle. We are also able to manufacture against customer requests in all types of sizes & materials.
capacity
Size 1. 3 4 (inches) 1 2 C 114 168 273 324 D 240 340 420 490 H 320 500 700 800 H1 160 230 280 330 Dimensions : C,D,H,H1, are in millimeters ( mm ) OTHER SIZES ON REQUEST
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
FLAME ARRESTORS
During the tank filling, the breathing valve expel over the tank some gas that could burn. The tank has to be protected to avoid that the flames spread inside the tank. This is the reason why a flame stopper is installed between the tank and the breathing valve and it has to: Defeat the flame Resist to make the hot fade away Resist to the shock wave producer by an external explosion The flame arrestor efficiency is reduced by the flame arrestor element and by the fifth that is inside it. Considering all these things, CDB engineering produce flame arrestor element only in SS316 and is easy to disassemble for a frequent maintenance. The flame stopper cdb engineering can be also manufactured in cast body and there are many different type as: Standard flame arrestor from 2 to 12 used for breathing valve assembly or free breath. Box flame arrestor from 2 to 6 is used for the assembly of breath valve with convoyed breath or on the final part of pipe. The flame arrestor element can be slipped removing the cover from the box an the arrestor. Cdb engineering is also able to manufacture flame arrestor with welded body and are available made of the following material : body built with a diameter reduction in a105n or with a diameter reductions in wp304l or 316l and flange in f304l or 316l from 2 t0 12. Body and flame arrestor element built with a plate in SS316L thk 3mm. Sliding flange in s.s.316l from 2 to 6. Body and flame arrestor in s.s. 316l thk 3mm, fixed flanges in ss316l from 2 to 6
Materials and product codes for Fig.422.2 Flame Arrester Items Description Materials 1 2 3 4 5 6 Body Container Elements Gaskets Bolts Label Carbon steel SS316L SS316L SS304L SS316L SS316L SS316L SS316L SS316L 8-8A/B8-B8A SS304 Hastelloy C276 SS316L SS316L 8-8A/B8-B8A SS304 Carbon steel Carbon steel SS316L B7/2H SS304
Dimensions & weights Dimensions DN (mm) (xx) A H 2 3 4 6 8 10 12 230 280 345 483 597 699 813 333 422 440 580 897 1211 1232
EN.12874 ASME VIII, IX 10 Bar -10/+250 C for C.S. -120/+250 C for S.S. In-line deflagration, vertical, bidirectional, max distance from fire source DNx50 60 C >0.9 IIA Ex-GIIA CE1370 dimensional pressure 19.38 Bar
Max operating temperature MESG Gas group Atex certificated Ped certificated Factory tested:
Size/s Connections
External finiture:
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
EXHAUST HEADS EH
CDB engineering fabricated exhaust heads have been specifically designed for safe discharge of steam to atmosphere, to meet all customer requirements including noise reduction; CDB exhaust heads grant efficient separation of water from steam that can be drained trough drain connection installed on the bottom of the body. Suitable for installation on blow down vessel, boiler, storage tanks, Standard features include carbon steel and stainless steel . We are also able to manufacture against customer requests in all types of sizes & materials.
DIMENSIONS "I" INLET 2" 2 1/2" 3" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" "d" OUTLET 6" 6" 6" 6" 8" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" 42" DRAIN 3/4" 3/4" 3/4" 1" 1 1/2" 1 1/2" 2" 2" 3" 3" 3" 3" 3" 3" 4" 4" Weight (kg) 40 45 47 50 70 80 150 160 250 280 300 550 900 950 1000 1400 "D" 273 273 273 273 356 356 508 508 508 610 610 914 1066 1066 1220 1370 "H" 530 530 530 530 530 530 660 660 760 760 960 1370 1500 1500 1650 1900
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
SPECTACLE FLANGES
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering
C D B Engineering
S.p.A.
CDB engineering
C D B Engineering
S.p.A.
CDB engineering
C D B Engineering
S.p.A.
PressureTemperatureRatingasperASMEB16.34
CDB engineering
C D B Engineering
S.p.A.
PressureTemperatureRatingasperASMEB16.34
CDB engineering
C D B Engineering
S.p.A.
PressureTemperatureRatingasperASMEB16.34
CDB Engineering reserve the right to carry out any necessary modification without prior notice
CDB engineering