Welder/Operator Qualification Test Record


Name
Welding Procedure Specification No. Welding Process(es) GMAW Mode of Transfer for GMAW

Joe Estrada 46

Identification No. Rev Type

Date Semi-automatic

11/19/2007

Record Actual Values Used in Qualification Variables Joint Joint Type Backing Material Type Groove Welded from:

Qualification Range

Tee

tee, Lap

one side or both sides


Base Metal Material Specification Sheet Steel Supporting Steel Sheet Thickness Groove Fillet Arc Plug Arc Spot Arc Seam

A653 to A653

sheet to sheet sheet to support steel

12 ga.

same or thicker

Coating(s) Type Thickness


Position Groove Fillet Arc Plug Arc Spot Arc Seam

Galvanized

same and/or no coating

F, H

Gas Electrode
Size Group Designation

Arg 75%-CO2 25%

any combination of Ar-CO2

0.035" 6
VISUAL EXAMINATION RESULTS

Specimen 1 Appearance Reinforcement Test Conducted By CWI No. Laboratory Test No.

PASS UNIFORM N/A

Cracks

Specimen 2 NONE
Diam of Arc Nugget Signature

PASS Undercut N/A

NONE

Michel Valdivia

7111751
FIELD Date of Test 11/29/2007

The undersigned certify that the statements in this record are correct and that the test welds were prepared and tested in accordance with the requirements of 4.6 of ANSI/AWS D1.3-98, Structural Welding Code-Sheet Steel.

Company

WEST COAST WELDING

Authorized By

JESSE MEJIA Date

Caltrans Witness

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Name
Welding Procedure Specification No. Welding Process(es) GMAW Mode of Transfer for GMAW

Leo Savoian 46

Identification No. Rev Type

Date Semi-automatic

11/19/2007

Record Actual Values Used in Qualification Variables Joint Joint Type Backing Material Type Groove Welded from:

Qualification Range

Tee

tee, Lap

one side or both sides


Base Metal Material Specification Sheet Steel Supporting Steel Sheet Thickness Groove Fillet Arc Plug Arc Spot Arc Seam

A653 to A653

sheet to sheet sheet to support steel

12 ga.

same or thicker

Coating(s) Type Thickness


Position Groove Fillet Arc Plug Arc Spot Arc Seam

Galvanized

same and/or no coating

F, H

Gas Electrode
Size Group Designation

Arg 75%-CO2 25%

any combination of Ar-CO2

0.035" 6
VISUAL EXAMINATION RESULTS

Specimen 1 Appearance Reinforcement Test Conducted By CWI No. Laboratory Test No.

PASS UNIFORM N/A

Cracks

Specimen 2 NONE
Diam of Arc Nugget Signature

PASS Undercut N/A

NONE

Michel Valdivia

7111751
FIELD Date of Test 11/29/2007

The undersigned certify that the statements in this record are correct and that the test welds were prepared and tested in accordance with the requirements of 4.6 of ANSI/AWS D1.3-98, Structural Welding Code-Sheet Steel.

Company

WEST COAST WELDING

Authorized By

JESSE MEJIA Date

Caltrans Witness

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Name
Welding Procedure Specification No. Welding Process(es) GMAW Mode of Transfer for GMAW

Charles Prince 46

Identification No. Rev Type

Date Semi-automatic

11/19/2007

Record Actual Values Used in Qualification Variables Joint Joint Type Backing Material Type Groove Welded from:

Qualification Range

Tee

tee, Lap

one side or both sides


Base Metal Material Specification Sheet Steel Supporting Steel Sheet Thickness Groove Fillet Arc Plug Arc Spot Arc Seam

A653 to A653

sheet to sheet sheet to support steel

12 ga.

same or thicker

Coating(s) Type Thickness


Position Groove Fillet Arc Plug Arc Spot Arc Seam

Galvanized

same and/or no coating

F, H

Gas Electrode
Size Group Designation

Arg 75%-CO2 25%

any combination of Ar-CO2

0.035" 6
VISUAL EXAMINATION RESULTS

Specimen 1 Appearance Reinforcement Test Conducted By CWI No. Laboratory Test No.

PASS UNIFORM N/A

Cracks

Specimen 2 NONE
Diam of Arc Nugget Signature

PASS Undercut N/A

NONE

Michel Valdivia

7111751
FIELD Date of Test 11/29/2007

The undersigned certify that the statements in this record are correct and that the test welds were prepared and tested in accordance with the requirements of 4.6 of ANSI/AWS D1.3-98, Structural Welding Code-Sheet Steel.

Company

WEST COAST WELDING

Authorized By

JESSE MEJIA Date

Caltrans Witness

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Name
Welding Procedure Specification No. Welding Process(es) SMAW Mode of Transfer for GMAW

Leo Savoian 00045 N/A

Identification No. Rev Type

Date Manual

11/19/2007

Record Actual Values Used in Qualification Variables Joint Joint Type Backing Material Type Groove Welded from:

Qualification Range

Tee

tee, Lap

one side or both sides


Base Metal Material Specification Sheet Steel Supporting Steel Sheet Thickness Groove Fillet Arc Plug Arc Spot Arc Seam

A653 to A653

sheet to sheet sheet to support steel

12 ga.

same or thicker

Coating(s) Type Thickness


Position Groove Fillet Arc Plug Arc Spot Arc Seam

Galvanized

same and/or no coating

F, H

Gas Electrode
Size Group Designation

1/8" 1
VISUAL EXAMINATION RESULTS

Specimen 1 Appearance Reinforcement Test Conducted By CWI No. Laboratory Test No.

PASS UNIFORM N/A

Cracks

Specimen 2 NONE
Diam of Arc Nugget Signature

PASS Undercut N/A

NONE

Michel Valdivia

7111751
FIELD Date of Test 11/29/2007

The undersigned certify that the statements in this record are correct and that the test welds were prepared and tested in accordance with the requirements of 4.6 of ANSI/AWS D1.3-98, Structural Welding Code-Sheet Steel.

Company

WEST COAST WELDING

Authorized By

JESSE MEJIA Date

Caltrans Witness

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Name
Welding Procedure Specification No. Welding Process(es) SMAW Mode of Transfer for GMAW

Charles Prince 00045 N/A

Identification No. Rev Type

Date Manual

11/19/2007

Record Actual Values Used in Qualification Variables Joint Joint Type Backing Material Type Groove Welded from:

Qualification Range

Tee

tee, Lap

one side or both sides


Base Metal Material Specification Sheet Steel Supporting Steel Sheet Thickness Groove Fillet Arc Plug Arc Spot Arc Seam

A653 to A653

sheet to sheet sheet to support steel

12 ga.

same or thicker

Coating(s) Type Thickness


Position Groove Fillet Arc Plug Arc Spot Arc Seam

Galvanized

same and/or no coating

F, H

Gas Electrode
Size Group Designation

1/8" 1
VISUAL EXAMINATION RESULTS

Specimen 1 Appearance Reinforcement Test Conducted By CWI No. Laboratory Test No.

PASS UNIFORM N/A

Cracks

Specimen 2 NONE
Diam of Arc Nugget Signature

PASS Undercut N/A

NONE

Michel Valdivia

7111751
FIELD Date of Test 11/29/2007

The undersigned certify that the statements in this record are correct and that the test welds were prepared and tested in accordance with the requirements of 4.6 of ANSI/AWS D1.3-98, Structural Welding Code-Sheet Steel.

Company

WEST COAST WELDING

Authorized By

JESSE MEJIA Date

Caltrans Witness

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Name
Welding Procedure Specification No. Welding Process(es) SMAW Mode of Transfer for GMAW

Dave Corley 45 N/A

Identification No. Rev Type

Date Manual

11/19/2007

Record Actual Values Used in Qualification Variables Joint Joint Type Backing Material Type Groove Welded from:

Qualification Range

Tee

tee, Lap

one side or both sides


Base Metal Material Specification Sheet Steel Supporting Steel Sheet Thickness Groove Fillet Arc Plug Arc Spot Arc Seam

A653 to A653

sheet to sheet sheet to support steel

12 ga.

same or thicker

Coating(s) Type Thickness


Position Groove Fillet Arc Plug Arc Spot Arc Seam

Galvanized

same and/or no coating

F, H

Gas Electrode
Size Group Designation

1/8" 1
VISUAL EXAMINATION RESULTS

Specimen 1 Appearance Reinforcement Test Conducted By CWI No. Laboratory Test No.

PASS UNIFORM N/A

Cracks

Specimen 2 NONE
Diam of Arc Nugget Signature

PASS Undercut N/A

NONE

Michel Valdivia

7111751
FIELD Date of Test 11/29/2007

The undersigned certify that the statements in this record are correct and that the test welds were prepared and tested in accordance with the requirements of 4.6 of ANSI/AWS D1.3-98, Structural Welding Code-Sheet Steel.

Company

WEST COAST WELDING

Authorized By

JESSE MEJIA Date

Caltrans Witness

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Name
Welding Procedure Specification No. Welding Process(es) GMAW Mode of Transfer for GMAW

Dave Corley 46

Identification No. Rev Type

Date Semi-automatic

11/19/2007

Record Actual Values Used in Qualification Variables Joint Joint Type Backing Material Type Groove Welded from:

Qualification Range

Tee

tee, Lap

one side or both sides


Base Metal Material Specification Sheet Steel Supporting Steel Sheet Thickness Groove Fillet Arc Plug Arc Spot Arc Seam

A653 to A653

sheet to sheet sheet to support steel

12 ga.

same or thicker

Coating(s) Type Thickness


Position Groove Fillet Arc Plug Arc Spot Arc Seam

Galvanized

same and/or no coating

F, H

Gas Electrode
Size Group Designation

Arg 75%-CO2 25%

any combination of Ar-CO2

0.035" 6
VISUAL EXAMINATION RESULTS

Specimen 1 Appearance Reinforcement Test Conducted By CWI No. Laboratory Test No.

PASS UNIFORM N/A

Cracks

Specimen 2 NONE
Diam of Arc Nugget Signature

PASS Undercut N/A

NONE

Michel Valdivia

7111751
FIELD Date of Test 11/29/2007

The undersigned certify that the statements in this record are correct and that the test welds were prepared and tested in accordance with the requirements of 4.6 of ANSI/AWS D1.3-98, Structural Welding Code-Sheet Steel.

Company

WEST COAST WELDING

Authorized By

JESSE MEJIA Date

Caltrans Witness

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


DAVE CORLEY SMAW Type Manual Position 3G VERTICAL UP Welding Procedure Specification No. 3 Material Specification ASTM A-36 / 709, gr. 50 Joint thickness or Diameter/Wall thickness 1" Thickness range this qualifies UNLIMITED
Welding Process

Name

Identification No.

FILLER METAL Specification no. Backing Filler metal diameter


Flux / Gas

A 5.1 YES 1/8"

Classification

E-7018-H4R

F no.

NONE VISUAL INSPECTION

Appearance

Satisfactory

Undercut

None

Piping porosity

None

Guided Bend Test Results Type Side Side Test conducted by per Result Pass Pass Arrow Inspection & Testing, Inc. Victor Fonseca Fillet Test Results Appearance N/A Fracture test root penetration Test conducted by per Fillet size N/A Macroetch Laboratory test no. Test date RADIOGRAPHIC TEST RESULTS
Film ID

Type

Result

Laboratory test no. 109-07 Test date 12/5/2007

N/A N/A

Results

Remarks

Film ID

Results

Remarks

Test witnessed by per

N/A N/A

Test no. Test date

N/A N/A

We, the undersigned, certify that the statements in this record are correct and that the welds were prepared and tested
in accordance with the requirements of AASHTO/AWS D1.5, 2002 Bridge Welding Code.

Contractor Authorized by Test witness


Results reviewed

WEST COAST WELDING JESSE MEJIA


Agency Acceptance

Date Date

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


DAVE CORLEY SMAW Type Manual Position 4G OVERHEAD Welding Procedure Specification No. 3 Material Specification ASTM A-36 / 709, gr. 50 Joint thickness or Diameter/Wall thickness 1" Thickness range this qualifies UNLIMITED
Welding Process

Name

Identification No.

FILLER METAL Specification no. Backing Filler metal diameter


Flux / Gas

A 5.1 YES 1/8"

Classification

E7018

F no.

NONE VISUAL INSPECTION

Appearance

Satisfactory

Undercut

None

Piping porosity

None

Guided Bend Test Results Type Side Side Test conducted by per Result Pass Pass Arrow Inspection & Testing, Inc. Victor Fonseca Fillet Test Results Appearance N/A Fracture test root penetration Test conducted by per Fillet size N/A Macroetch Laboratory test no. Test date RADIOGRAPHIC TEST RESULTS
Film ID

Type

Result

Laboratory test no. 110-07 Test date 12/5/2007

N/A N/A

Results

Remarks

Film ID

Results

Remarks

Test witnessed by per

N/A N/A

Test no. Test date

N/A N/A

We, the undersigned, certify that the statements in this record are correct and that the welds were prepared and tested
in accordance with the requirements of AASHTO/AWS D1.5, 2002 Bridge Welding Code.

Contractor Authorized by Test witness


Results reviewed

WEST COAST WELDING JESSE MEJIA


Agency Acceptance

Date Date

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


LEO SAVOIAN SMAW Type Manual Position 4G OVERHEAD Welding Procedure Specification No. 3 Material Specification ASTM A-36 / 709, gr. 50 Joint thickness or Diameter/Wall thickness 1" Thickness range this qualifies UNLIMITED
Welding Process

Name

Identification No.

FILLER METAL Specification no. Backing Filler metal diameter


Flux / Gas

A 5.1 YES 1/8"

Classification

E7018

F no.

NONE VISUAL INSPECTION

Appearance

Satisfactory

Undercut

None

Piping porosity

None

Guided Bend Test Results Type Side Side Test conducted by per Result Pass Pass Arrow Inspection & Testing, Inc. Victor Fonseca Fillet Test Results Appearance N/A Fracture test root penetration Test conducted by per Fillet size N/A Macroetch Laboratory test no. Test date RADIOGRAPHIC TEST RESULTS
Film ID

Type

Result

Laboratory test no. 106-07 Test date 12/5/2007

N/A N/A

Results

Remarks

Film ID

Results

Remarks

Test witnessed by per

N/A N/A

Test no. Test date

N/A N/A

We, the undersigned, certify that the statements in this record are correct and that the welds were prepared and tested
in accordance with the requirements of AASHTO/AWS D1.5, 2002 Bridge Welding Code.

Contractor Authorized by Test witness


Results reviewed

WEST COAST WELDING JESSE MEJIA


Agency Acceptance

Date Date

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


LEO SAVOIAN SMAW Type Manual Position 3G VERTICAL UP Welding Procedure Specification No. 3 Material Specification ASTM A-36 / 709, gr. 50 Joint thickness or Diameter/Wall thickness 1" Thickness range this qualifies UNLIMITED
Welding Process

Name

Identification No.

FILLER METAL Specification no. Backing Filler metal diameter


Flux / Gas

A 5.1 YES 1/8"

Classification

E-7018-H4R

F no.

NONE VISUAL INSPECTION

Appearance

Satisfactory

Undercut

None

Piping porosity

None

Guided Bend Test Results Type Side Side Test conducted by per Result Pass Pass Arrow Inspection & Testing, Inc. Victor Fonseca Fillet Test Results Appearance N/A Fracture test root penetration Test conducted by per Fillet size N/A Macroetch Laboratory test no. Test date RADIOGRAPHIC TEST RESULTS
Film ID

Type

Result

Laboratory test no. 112-07 Test date 12/5/2007

N/A N/A

Results

Remarks

Film ID

Results

Remarks

Test witnessed by per

N/A N/A

Test no. Test date

N/A N/A

We, the undersigned, certify that the statements in this record are correct and that the welds were prepared and tested
in accordance with the requirements of AASHTO/AWS D1.5, 2002 Bridge Welding Code.

Contractor Authorized by Test witness


Results reviewed

WEST COAST WELDING JESSE MEJIA


Agency Acceptance

Date Date

ARROW INSPECTION AND TESTING


12631 E. Imperial Highway, Suite A-114 Santa Fe Springs, CA 90670 Ph. 562-484-0344 Fax 562-484-3885

Welder/Operator Qualification Test


Welder Welding Process Manual Position In accordance with procedure specification no. Material Specification Backing Backing Material Identification No. Semiautomatic (Weld Progression) Diameter and/or Thickness Range of thickness qualified Machine

FILLER METAL
Specification no. Filler Metal Manufacturer Classification F. No. Filler Metal Diameter

VISUAL INSPECTION
Appearance Type Undercut Result Piping Porosity Type Result

Test Conducted by: By

Laboratory Test No. Date of Test

FILLER TEST RESULTS


Appearance Fracture test root penetration Description of any crack Test Conducted by: By Film I.D. Results Remarks Fillet Size Macroetch Laboratory Test No. Date of Test Film I.D. Results Remarks

Test witnessed by Laboratory test No. Per Test Date We, the undersigned, certify that the statements in this record are correct and that the welds, were prepared and tested in accordance with the requirements of AASHTO/AWS D1.1, Structural Steel Welding Code. Test witness Results reviewed Manufacturer or contractor Authorized by Agency Date

Date

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


DAVE CORLEY Identification No. FCAW Type Semi-automatic Position 3G VERTICAL UP Welding Procedure Specification No. WCW-709-71T8-3G-06 Material Specification ASTM A-572 / 709, gr. 50 Joint thickness or Diameter/Wall thickness 1" Thickness range this qualifies UNLIMITED
Welding Process

Name

FILLER METAL Specification no. Backing Filler metal diameter


Flux / Gas

A 5.20 YES 0.072"

Classification Lincoln NR 232 NONE VISUAL INSPECTION

E71T-8

F no.

Appearance

Satisfactory

Undercut

None

Piping porosity

None

Guided Bend Test Results Type Side Side Test conducted by per Result Pass Pass Arrow Inspection & Testing, Inc. Victor Fonseca Fillet Test Results Appearance N/A Fracture test root penetration Test conducted by per Fillet size N/A Macroetch Laboratory test no. Test date RADIOGRAPHIC TEST RESULTS
Film ID

Type

Result

Laboratory test no. 105-07 Test date 12/5/2007

N/A N/A

Results

Remarks

Film ID

Results

Remarks

Test witnessed by per

N/A N/A

Test no. Test date

N/A N/A

We, the undersigned, certify that the statements in this record are correct and that the welds were prepared and tested
in accordance with the requirements of AASHTO/AWS D1.5, 2002 Bridge Welding Code.

Contractor Authorized by Test witness


Results reviewed

WEST COAST WELDING JESSE MEJIA


Agency Acceptance

Date Date

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


LEO SAVOIAN Identification No. FCAW Type Semi-automatic Position 4G OVERHEAD Welding Procedure Specification No. WCW-709-71T8-4G-06 Material Specification ASTM A-572 / 709, gr. 50 Joint thickness or Diameter/Wall thickness 1" Thickness range this qualifies UNLIMITED
Welding Process

Name

FILLER METAL Specification no. Backing Filler metal diameter


Flux / Gas

A 5.20 YES 0.072"

Classification NR 232 Lincoln NONE VISUAL INSPECTION

E71T-8

F no.

Appearance

Satisfactory

Undercut

None

Piping porosity

None

Guided Bend Test Results Type Side Side Test conducted by per Result Pass Pass Arrow Inspection & Testing, Inc. Victor Fonseca Fillet Test Results Appearance N/A Fracture test root penetration Test conducted by per Fillet size N/A Macroetch Laboratory test no. Test date RADIOGRAPHIC TEST RESULTS
Film ID

Type

Result

Laboratory test no. 105-07 Test date 12/5/2007

N/A N/A

Results

Remarks

Film ID

Results

Remarks

Test witnessed by per

N/A N/A

Test no. Test date

N/A N/A

We, the undersigned, certify that the statements in this record are correct and that the welds were prepared and tested
in accordance with the requirements of AASHTO/AWS D1.5, 2002 Bridge Welding Code.

Contractor Authorized by Test witness


Results reviewed

WEST COAST WELDING JESSE MEJIA


Agency Acceptance

Date Date

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


LEO SAVOIAN Identification No. FCAW Type Semi-automatic Position 3G VERTICAL UP Welding Procedure Specification No. WCW-709-71T8-3G-06 Material Specification ASTM A-572 / 709, gr. 50 Joint thickness or Diameter/Wall thickness 1" Thickness range this qualifies UNLIMITED
Welding Process

Name

FILLER METAL Specification no. Backing Filler metal diameter


Flux / Gas

A 5.20 YES 0.072"

Classification Lincoln NR 232 NONE VISUAL INSPECTION

E71T-8

F no.

Appearance

Satisfactory

Undercut

None

Piping porosity

None

Guided Bend Test Results Type Side Side Test conducted by per Result Pass Pass Arrow Inspection & Testing, Inc. Victor Fonseca Fillet Test Results Appearance N/A Fracture test root penetration Test conducted by per Fillet size N/A Macroetch Laboratory test no. Test date RADIOGRAPHIC TEST RESULTS
Film ID

Type

Result

Laboratory test no. 105-07 Test date 12/5/2007

N/A N/A

Results

Remarks

Film ID

Results

Remarks

Test witnessed by per

N/A N/A

Test no. Test date

N/A N/A

We, the undersigned, certify that the statements in this record are correct and that the welds were prepared and tested
in accordance with the requirements of AASHTO/AWS D1.5, 2002 Bridge Welding Code.

Contractor Authorized by Test witness


Results reviewed

WEST COAST WELDING JESSE MEJIA


Agency Acceptance

Date Date

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Name
Welding Procedure Specification No. Welding Process(es) GMAW Mode of Transfer for GMAW

Josh Mejia 46

Identification No. Rev Type

Date Semi-automatic

11/19/2007

Record Actual Values Used in Qualification Variables Joint Joint Type Backing Material Type Groove Welded from:

Qualification Range

Tee

tee, Lap

one side or both sides


Base Metal Material Specification Sheet Steel Supporting Steel Sheet Thickness Groove Fillet Arc Plug Arc Spot Arc Seam

A653 to A653

sheet to sheet sheet to support steel

12 ga.

same or thicker

Coating(s) Type Thickness


Position Groove Fillet Arc Plug Arc Spot Arc Seam

Galvanized

same and/or no coating

F, H

Gas Electrode
Size Group Designation

Arg 75%-CO2 25%

any combination of Ar-CO2

0.035" 6
VISUAL EXAMINATION RESULTS

Specimen 1 Appearance Reinforcement Test Conducted By CWI No. Laboratory Test No.

PASS UNIFORM N/A

Cracks

Specimen 2 NONE
Diam of Arc Nugget Signature

PASS Undercut N/A

NONE

CARLOS SANTANA

97080771
FIELD Date of Test 6/25/2007

The undersigned certify that the statements in this record are correct and that the test welds were prepared and tested in accordance with the requirements of 4.6 of ANSI/AWS D1.3-98, Structural Welding Code-Sheet Steel.

Company

WEST COAST WELDING

Authorized By

JESSE MEJIA Date

Caltrans Witness

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Name
Welding Procedure Specification No. Welding Process(es) GMAW Mode of Transfer for GMAW

Jesse Mejia 46

Identification No. Rev Type

Date Semi-automatic

11/19/2007

Record Actual Values Used in Qualification Variables Joint Joint Type Backing Material Type Groove Welded from:

Qualification Range

Tee

tee, Lap

one side or both sides


Base Metal Material Specification Sheet Steel Supporting Steel Sheet Thickness Groove Fillet Arc Plug Arc Spot Arc Seam

A653 to A653

sheet to sheet sheet to support steel

12 ga.

same or thicker

Coating(s) Type Thickness


Position Groove Fillet Arc Plug Arc Spot Arc Seam

Galvanized

same and/or no coating

F, H

Gas Electrode
Size Group Designation

Arg 75%-CO2 25%

any combination of Ar-CO2

0.035" 6
VISUAL EXAMINATION RESULTS

Specimen 1 Appearance Reinforcement Test Conducted By CWI No. Laboratory Test No.

PASS UNIFORM N/A

Cracks

Specimen 2 NONE
Diam of Arc Nugget Signature

PASS Undercut N/A

NONE

CARLOS SANTANA

97080771
FIELD Date of Test 6/25/2007

The undersigned certify that the statements in this record are correct and that the test welds were prepared and tested in accordance with the requirements of 4.6 of ANSI/AWS D1.3-98, Structural Welding Code-Sheet Steel.

Company

WEST COAST WELDING

Authorized By

JESSE MEJIA Date

Caltrans Witness

ARROW INSPECTION AND TESTING


12631 E. Imperial Highway, Suite A-114 Santa Fe Springs, CA 90670 Ph. 562-484-0344 Fax 562-484-3885

Welder/Operator Qualification Test


Welder Gerardo Rodriguez Welding Process SMAW Manual Position Vertical 3G In accordance with procedure specification no. Material Specification A36 Backing Yes Backing Material X Identification No. Semiautomatic (Weld Progression) UMS-4 Diameter and/or Thickness Range of thickness qualified 556-43-8610 Machine Up-Hill 3/8" 1/8" to 3/4" Max

A36

FILLER METAL
Specification no. AWS 5.1 Filler Metal Manufacturer Classification Lincoln E-7078 F. No. Filler Metal Diameter 1/8"

VISUAL INSPECTION
Appearance Acceptable Type Visual Test Conducted by: By Undercut Result Pass Arrow Inspection and Testing Steven McCall None Piping Porosity Type None Result

Laboratory Test No. Date of Test

556-43-8610-V Tuesday 5-22-01

FILLET TEST RESULTS


Appearance Fracture test root penetration Description of any crack Test Conducted by: By Film I.D. Results Pass Pass Remarks Fillet Size Macroetch Laboratory Test No. Date of Test Film I.D. Results Remarks

RT Technician

Laboratory test No. AIT-001 Per AWS D1.1 Test Date 5/24/2001 We, the undersigned, certify that the statements in this record are correct and that the welds, were prepared and tested in accordance with the requirements of AASHTO/AWS D1.1, Structural Steel Welding Code. Test witness Results reviewed Manufacturer or contractor Authorized by Agency University Mechanical Date Date

David Lee

5/25/2001

ARROW INSPECTION AND TESTING


12631 E. Imperial Highway, Suite A-114 Santa Fe Springs, CA 90670 Ph. 562-484-0344 Fax 562-484-3885

Welder/Operator Qualification Test


Welder Michael W mcMullen Welding Process SMAW Manual Position Overhead 4G In accordance with procedure specification no. Material Specification A36 Backing Yes Backing Material X Identification No. Semiautomatic (Weld Progression) UMS-4 Diameter and/or Thickness Range of thickness qualified 356-46-4944 Machine

A36

3/8" 1/8" to 3/4" Max

FILLER METAL
Specification no. AWS 5.1 Filler Metal Manufacturer Classification Lincoln E-7078 F. No. Filler Metal Diameter 1/8"

VISUAL INSPECTION
Appearance Acceptable Type Visual Test Conducted by: By Undercut Result Pass Arrow Inspection and Testing Carlos Santana None Piping Porosity Type Face Root Laboratory Test No. Date of Test None Result Fail Pass 356-46-4944 5/22/2001

FILLET TEST RESULTS


Appearance Fracture test root penetration Description of any crack Test Conducted by: By Film I.D. Results Remarks Fillet Size Macroetch Laboratory Test No. Date of Test Film I.D. Results Remarks

RT Technician

Laboratory test No. Per Test Date We, the undersigned, certify that the statements in this record are correct and that the welds, were prepared and tested in accordance with the requirements of AASHTO/AWS D1.1, Structural Steel Welding Code. Test witness Results reviewed Manufacturer or contractor Authorized by Agency University Mechanical Date Date

David Lee

5/25/2001

ARROW INSPECTION AND TESTING


12631 E. Imperial Highway, Suite A-114 Santa Fe Springs, CA 90670 Ph. 562-484-0344 Fax 562-484-3885

Welder/Operator Qualification Test


Welder Michael W mcMullen Welding Process SMAW Manual Position Vertical 3G In accordance with procedure specification no. Material Specification A36 Backing Yes Backing Material X Identification No. Semiautomatic (Weld Progression) UMS-4 Diameter and/or Thickness Range of thickness qualified 356-46-4944 Machine Up-Hill 3/8" 1/8" to 3/4" Max

A36

FILLER METAL
Specification no. AWS 5.1 Filler Metal Manufacturer Classification Lincoln E-7078 F. No. Filler Metal Diameter 1/8"

VISUAL INSPECTION
Appearance Acceptable Type Visual Test Conducted by: By Undercut Result Pass Arrow Inspection and Testing Carlos Santana None Piping Porosity Type Face Root Laboratory Test No. Date of Test None Result Pass Pass 356-46-4944 5/22/2001

FILLET TEST RESULTS


Appearance Fracture test root penetration Description of any crack Test Conducted by: By Film I.D. Results Remarks Fillet Size Macroetch Laboratory Test No. Date of Test Film I.D. Results Remarks

RT Technician

Laboratory test No. Per Test Date We, the undersigned, certify that the statements in this record are correct and that the welds, were prepared and tested in accordance with the requirements of AASHTO/AWS D1.1, Structural Steel Welding Code. Test witness Results reviewed Manufacturer or contractor Authorized by Agency University Mechanical Date Date

David Lee

5/25/2001

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Welder Simon R. Reyes Welding Procedure Specification No. GMAW 001 Fillet Rev
Type of Welder

Name

Identification No.

Date
Record Actual Values Used in Qualification

SRR 6/11/2007

Qualification Range

Variables Process/Type Electrode (single or multiple) Current/Polarity Position Weld Progression Backing (YES or NO) [Table 4.11, Item (7)] Material/Spec. Base Metal Thickness: (Plate) Groove Fillet Thickness: (Pipe/tube) Groove Fillet Diameter: (Pipe) Groove Fillet Filler Metal [Table 4.11, Item (3)] Spec. No. Class F-No.

GMAW Single DCEP 3F Up N/A A36

Single

1F, 2F, 3F Up N/A

N/A 1/2" N/A N/A N/A N/A ER70S-6 AWS A5.18 Argon

N/A 1/8" to Unlimited N/A 1/8" to Unlimited N/A 1/8" to Unlimited

Gas/Flux Type
Other

Argon

VISUAL INSPECTION Acceptable YES or NO Yes Type Result Guided Bend Test Results Type Result

Fillet TestFillet Result Appearance Acceptable Size Fracture Test Root Penetration Acceptable Macro etch (Describe the location, nature, and size of any crack or tearing of the specimen.) Inspected by Test Number Rene Mora Test Number Organization Arrow Inspection and Testing Inc. Date

5/16" Acceptable Tear at Base metal #03-0607 6/11/2007

We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, welded, and tested

in conformance with the requirements of Section 4 of AWS Dl .1/Di .1 M, Structural Welding CodeSteel.
Manufacturer or Contractor Authorized By

Ace Fence

Authorized By

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Type of Welder

Name
Welding Procedure Specification No.

Welder Alfredo Alba


Rev

Identification No.

Date
Record Actual Values Used in Qualification

11/8/2007

Qualification Range

Variables Process/Type Electrode (single or multiple) Current/Polarity Position Weld Progression Backing (YES or NO) [Table 4.11, Item (7)] Material/Spec. Base Metal Thickness: (Plate) Groove Fillet Thickness: (Pipe/tube) Groove Fillet Diameter: (Pipe) Groove Fillet Filler Metal [Table 4.11, Item (3)] Spec. No. Class F-No.

FCAW Single DCEN 3G Up Yes A36

SINGLE

1G,2G,3G,1F,2F,3F Up YES

3/4"

1/8" - 1 1/2" 1/8" - 1 1/2" CJP 1/8" - 1 1/2" PJP 1/8" - UNLIMITED 1/8" to Unlimited 24" 24"

N/A N/A N/A N/A E71T-1 AWS A5.20 10 100% CO2

Gas/Flux Type
Other

N/A

VISUAL INSPECTION Acceptable YES or NO Yes Type Result Guided Bend Test Results Type Result

SIDE SIDE

PASS PASS

Fillet TestFillet Result Appearance Size Fracture Test Root Penetration Macroetch (Describe the location, nature, and size of any crack or tearing of the specimen.) Inspected by Test Number Test Number Frank Gasco Organization Date Arrow Inspection and Testing Inc.

11/8/2007

We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, welded, and tested

in conformance with the requirements of Section 4 of AWS D1.1/D1 .1 M, Structural Welding CodeSteel.
Manufacturer or Contractor Authorized By

American Sheet Metal, Inc.

Authorized By

ELI CHOUEIRY

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Welder JAIME TREJO Welding Procedure Specification No. FCAW
Type of Welder

Name

Identification No. Rev

Date
Record Actual Values Used in Qualification

4 8/27/2009

Qualification Range

Variables Process/Type Electrode (single or multiple) Current/Polarity Position Weld Progression Backing (YES or NO) [Table 4.11, Item (7)] Material/Spec. Base Metal Thickness: (Plate) Groove Fillet Thickness: (Pipe/tube) Groove Fillet Diameter: (Pipe) Groove Fillet Filler Metal [Table 4.11, Item (3)] Spec. No. Class F-No.

FCAW Single DCEN 6 GR Up Yes A36 API-5L ASTM A53-B

SINGLE

ALL Up YES A36

SCH 120-5/8 N/A 6"-OD N/A N/A A5.20 E71T-8 F-6 N/A N/A
VISUAL INSPECTION Acceptable YES or NO Yes

3/16"-UNLIMITED ALL 4"-UNLIMITED ALL

Gas/Flux Type
Other

N/A

Type

Result

Guided Bend Test Results Type

Result

SIDE SIDE

PASS PASS

SIDE SIDE

PASS PASS
N/A ACCEPTABLE

Fillet TestFillet Result Appearance ACCEPTABLE Size Fracture Test Root Penetration ACCEPTABLE Macroetch (Describe the location, nature, and size of any crack or tearing of the specimen.) Inspected by Test Number Test Number CARLOS SANTANA Organization Date Arrow Inspection and Testing Inc.

8/27/2009

We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, welded, and tested

in conformance with the requirements of Section 4 of AWS D1.1/D1 .1 M, Structural Welding CodeSteel.
Manufacturer or Contractor Authorized By

WEST COAST WELDING

Authorized By

JESSIE MEJIA

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Type of Welder

Name
Welding Procedure Specification No.

Welder Juan Alba


Rev

Identification No.

Date
Record Actual Values Used in Qualification

11/8/2007

Qualification Range

Variables Process/Type Electrode (single or multiple) Current/Polarity Position Weld Progression Backing (YES or NO) [Table 4.11, Item (7)] Material/Spec. Base Metal Thickness: (Plate) Groove Fillet Thickness: (Pipe/tube) Groove Fillet Diameter: (Pipe) Groove Fillet Filler Metal [Table 4.11, Item (3)] Spec. No. Class F-No.

FCAW Single DCEN 3G Up Yes A36

SINGLE

1G,2G,3G,1F,2F,3F Up YES

3/4"

1/8" - 1 1/2" 1/8" - 1 1/2" CJP 1/8" - 1 1/2" PJP 1/8" - UNLIMITED 1/8" to Unlimited 24" 24"

N/A N/A N/A N/A E71T-1 AWS A5.20 10 100% CO2

Gas/Flux Type
Other

N/A

VISUAL INSPECTION Acceptable YES or NO Yes Type Result Guided Bend Test Results Type Result

SIDE SIDE

PASS PASS

Fillet TestFillet Result Appearance Size Fracture Test Root Penetration Macroetch (Describe the location, nature, and size of any crack or tearing of the specimen.) Inspected by Test Number Test Number Frank Gasco Organization Date Arrow Inspection and Testing Inc.

11/8/2007

We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, welded, and tested

in conformance with the requirements of Section 4 of AWS D1.1/D1 .1 M, Structural Welding CodeSteel.
Manufacturer or Contractor Authorized By

American Sheet Metal, Inc.

Authorized By

ELI CHOUEIRY

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Welder ELMER BONILLA ID # 7939 Welding Process SMAW Manual YES Backing material CS Material Specification ASTM A53 GRADE B Position 6G Weld Progression UP Electrode SINGLE WPS # PRE-QUALIFIED Semiautomatic NO Diameter and/or Thickness Backing YES

6" / 3/8"

FILLER METAL
Specification no. A5.5 Classification Filler Metal Manufacturer Lincoln FILLER METAL QUALIFICATION RANGE: E 7018-H4R F. No. Filler Metal Diameter 4 1/8"

VISUAL INSPECTION
Appearance UNACCEPTABLE Type SIDE SIDE Test Conducted by: By Undercut Result FAIL PASS ARROW INSPECTION & TESTING FRANK GASCO NONE Piping Porosity Type SIDE SIDE Laboratory Test No. Date of Test 10/22/2007 NONE Result FAIL FAIL

FILLET TEST RESULTS


Appearance Fracture test root penetration Description of any crack Test Conducted by: By Film I.D. N/A Results Remarks N/A N/A N/A Fillet Size Macroetch N/A Laboratory Test No. Date of Test Film I.D. Results N/A N/A N/A N/A Remarks

RT Technician

Laboratory test No. Per Test Date We, the undersigned, certify that the statements in this record are correct and that the welds, were prepared and tested in accordance with the requirements of AWS D1.1, Structural Steel Welding Code. Test witness CARLOS SANTANA Manufacturer or contractor Authorized by RALPH AYALA III Agency AIT AYALA BORING Date Date 10/22/2007

10/18/2007

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Welder JUAN TRONCOSO ID # 9563 WPS # PRE-QUALIFIED Welding Process SMAW Manual YES Semiautomatic NO Backing YES Backing material CS Range of backing qualified YES Material Specification ASTM A53 GRADE B Diameter and/or Thickness 6" / 3/8" Position 6G Weld Progression UP Range of thickness qualified MIN 3/16"-UNLIMITED Electrode SINGLE Range of electrode qualified SINGLE POSITION QUALIFICATION RANGE: ALL, EXCEPT T-,Y-,K-GROOVE CJP

FILLER METAL
Specification no. A5.5 Classification E 7018-H4R F. No. Filler Metal Manufacturer Lincoln Filler Metal Diameter FILLER METAL QUALIFICATION RANGE: F-4 and LESS 4 1/8"

VISUAL INSPECTION
Appearance ACCEPTABLE Type SIDE SIDE Test Conducted by: FRANK GASCO By Undercut Result PASS PASS ARROW INSPECTION & TESTING NONE Piping Porosity Type SIDE SIDE Laboratory Test No. 10/22/2007 Date of Test NONE Result PASS PASS

Signature

FILLET TEST RESULTS


Appearance Fracture test root penetration Description of any crack Test Conducted by: By Film I.D. N/A Results Remarks N/A N/A N/A Fillet Size Macroetch N/A Laboratory Test No. Date of Test Film I.D. Results N/A N/A N/A N/A Remarks

RT Technician

Laboratory test No. Per Test Date We, the undersigned, certify that the statements in this record are correct and that the welds, were prepared and tested in accordance with the requirements of AWS D1.1, Structural Steel Welding Code. Test witness CARLOS SANTANA Manufacturer or contractor Authorized by RALPH AYALA III Agency AIT AYALA BORING, INC. Date Date 10/22/2007

10/18/2007

AYALA BORING, INC.

DATE

ARROW INSPECTION &TESTING, INC

DATE

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Welder LEONEL CALDERON ID # 2326 WPS # PRE-QUALIFIED Welding Process SMAW Manual YES Semiautomatic NO Backing YES Backing material CS Range of backing qualified YES Material Specification ASTM A53 GRADE B Diameter and/or Thickness 6" / 3/8" Position 6G Weld Progression UP Range of thickness qualified MIN 3/16"-UNLIMITED Electrode SINGLE Range of electrode qualified SINGLE POSITION QUALIFICATION RANGE: ALL, EXCEPT T-,Y-,K-GROOVE CJP

FILLER METAL
Specification no. A5.5 Classification E 7018-H4R F. No. Filler Metal Manufacturer Lincoln Filler Metal Diameter FILLER METAL QUALIFICATION RANGE: F-4 and LESS 4 1/8"

VISUAL INSPECTION
Appearance ACCEPTABLE Type SIDE SIDE Test Conducted by: FRANK GASCO By Undercut Result PASS PASS ARROW INSPECTION & TESTING NONE Piping Porosity Type SIDE SIDE Laboratory Test No. 10/22/2007 Date of Test NONE Result PASS PASS

Signature

FILLET TEST RESULTS


Appearance Fracture test root penetration Description of any crack Test Conducted by: By Film I.D. N/A Results Remarks N/A N/A N/A Fillet Size Macroetch N/A Laboratory Test No. Date of Test Film I.D. Results N/A N/A N/A N/A Remarks

RT Technician

Laboratory test No. Per Test Date We, the undersigned, certify that the statements in this record are correct and that the welds, were prepared and tested in accordance with the requirements of AWS D1.1, Structural Steel Welding Code. Test witness CARLOS SANTANA Manufacturer or contractor Authorized by RALPH AYALA III Agency AIT AYALA BORING, INC. Date Date 10/22/2007

10/18/2007

AYALA BORING, INC.

DATE

ARROW INSPECTION & TESTING, INC.

DATE

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Name
Welding Procedure Specification No. Rev Record Actual Values Used in Qualification Variables Joint Joint Type Backing Material Type Groove Welded from: Identification No.

Date
Qualification Range

one side or both sides


Base Metal Material Specification Sheet Steel Supporting Steel Sheet Thickness Groove Fillet Arc Plug Arc Spot Arc Seam

Coating(s) Type Thickness


Position Groove Fillet Arc Plug Arc Spot Arc Seam

Gas Electrode
Size Group Designation VISUAL EXAMINATION RESULTS

Specimen 1 Appearance Reinforcement Test Conducted By Laboratory Test No.

Specimen 2 Cracks
Diam of Arc Nugget Per Date of Test

Undercut

The undersigned certify that the statements in this record are correct and that the test welds were prepared and tested in accordance with the requirements of 4.6 of ANSI/AWS D1.3-98, Structural Welding Code-Sheet Steel.

Company

Authorized By

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Type of Welder

Welder
Identification No. Rev Record Actual Values Used in Qualification

Name
Welding Procedure Specification No.

Date
Qualification Range

Variables Process/Type Electrode (single or multiple) Current/Polarity Position Weld Progression Backing (YES or NO) [Table 4.11, Item (7)] Material/Spec. Base Metal Thickness: (Plate) Groove Fillet Thickness: (Pipe/tube) Groove Fillet Diameter: (Pipe) Groove Fillet Filler Metal [Table 4.11, Item (3)] Spec. No. Class F-No.

Gas/Flux Type
Other VISUAL INSPECTION Acceptable YES or NO Type Result Guided Bend Test Results Type Result

Fillet TestFillet Result Appearance Size Fracture Test Root Penetration Macro etch (Describe the location, nature, and size of any crack or tearing of the specimen.) Inspected by Test Number Test Number Organization Date
We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, welded, and tested

in conformance with the requirements of Section 4 of AWS D1 .1/D1 .1 M, Structural Welding CodeSteel.
Manufacturer or Contractor Authorized By

Authorized By

Welder Qualification Record


Company Name Supporting PQR # Operator Name Stud Material Material Specifications Weld Base Diameter DJ Scheffler Inc. DJS-Studs-0001 Michael Mason # 6348 Mild Steel ASTM A108 Grade C 1015 5/8" Test No. DJS-Studs-WQR-Mason Revision # 0 Date 11/6/2001 By Arrow Inspection & Testing Inc. Authorized By B. Becker Date 11/6/2001

BASE MATERIAL
Specification Alloy and Temper Group # II Coating Cleaning Method Decking Gage A572 Grade 50 Steel N/A Surface Condition HR CR N/A Wire Brush/Grinder N/A

SHAPE
Flat X Thickness Round Tube 0.72 Angle

FERRULE Part # Ferrule Description

104-053-014 5/8" @ Vertical Position

MACHINE DATA
Power Supply Make TRW/Nelson Welder Model 6500 Stud Gun Model TRW Series Welding Time Secs. 0.65 Cycles 36 5 % OCV Curret 1200 Polarity DCEN Lift Plunge (protrusion) Weld Cable Size Length 500' Max. Number of grounds (work piece leads) 2 (Two) Stud No. 1 2 Visual Acceptance Steven McCall Steven McCall Option #1 Bend Test Accepted 11-06-01 Accepted 11-06-01 POSITION Overhead Down hand 70 Angular Angle Iron - Inside Radius SHIELDING GAS Shielding Gas(es) Composition Flow Rate Option #2 Tension Test Side Hand X Degrees from normal Heel of Angle

N/A N/A N/A Option #3 Torque Test*

* Note: Torque test optional for threaded fasteners only. Mechanical Test Conducted by Arrow Inspection & Testing Inc.
Company

Date

11/6/2001

We, the undersigned certify that the statements in this record are correct and that the test welds were prepared, welded, and tested in accordance with the requirements of section 7 of ANSI/AWS D1.1, 2000 Structural Welding Cose-Steel.

Signed By
(Contractor / Applicator)

Title

Date

Welder Qualification Record


Company Name Supporting PQR # Operator Name Stud Material Material Specifications Weld Base Diameter DJ Scheffler Inc. DJS-Studs-0001 Steven Morgan #5832 Mild Steel ASTM A108 Grade C 1015 5/8" Test No. DJS-Studs-WQR-Morgan Revision # 0 Date 11/6/2001 By Arrow Inspection & Testing Inc. Authorized By B. Becker Date 11/6/2001

BASE MATERIAL
Specification Alloy and Temper Group # II Coating Cleaning Method Decking Gage A572 Grade 50 Steel N/A Surface Condition HR CR N/A Wire Brush/Grinder N/A

SHAPE
Flat X Thickness Round Tube 0.72 Angle

FERRULE Part # Ferrule Description

104-053-014 5/8" @ Vertical Position

MACHINE DATA
Power Supply Make TRW/Nelson Welder Model 6500 Stud Gun Model TRW Series Welding Time Secs. 0.65 Cycles 36 5 % OCV Curret 1200 Polarity DCEN Lift Plunge (protrusion) Weld Cable Size Length 500' Max. Number of grounds (work piece leads) 2 (Two) Stud No. 1 2 Visual Acceptance Steven McCall Steven McCall Option #1 Bend Test Accepted 11-06-01 Accepted 11-06-01 POSITION Overhead Down hand 70 Angular Angle Iron - Inside Radius SHIELDING GAS Shielding Gas(es) Composition Flow Rate Option #2 Tension Test Side Hand X Degrees from normal Heel of Angle

N/A N/A N/A Option #3 Torque Test*

* Note: Torque test optional for threaded fasteners only. Mechanical Test Conducted by Arrow Inspection & Testing Inc.
Company

Date

11/6/2001

We, the undersigned certify that the statements in this record are correct and that the test welds were prepared, welded, and tested in accordance with the requirements of section 7 of ANSI/AWS D1.1, 2000 Structural Welding Cose-Steel.

Signed By
(Contractor / Applicator)

Title

Date

Welder Qualification Record


Company Name Supporting PQR # Operator Name Stud Material Material Specifications Weld Base Diameter DJ Scheffler Inc. DJS-Studs-0001 Luis Alcala #9550 Mild Steel ASTM A108 Grade C 1015 5/8" Test No. DJS-Studs-WQR-Alcala Revision # 0 Date 11/6/2001 By Arrow Inspection & Testing Inc. Authorized By B. Becker Date 11/6/2001

BASE MATERIAL
Specification Alloy and Temper Group # II Coating Cleaning Method Decking Gage A572 Grade 50 Steel N/A Surface Condition HR CR N/A Wire Brush/Grinder N/A

SHAPE
Flat X Thickness Round Tube 0.72 Angle

FERRULE Part # Ferrule Description

104-053-014 5/8" @ Vertical Position

MACHINE DATA
Power Supply Make TRW/Nelson Welder Model 6500 Stud Gun Model TRW Series Welding Time Secs. 0.65 Cycles 36 5 % OCV Curret 1200 Polarity DCEN Lift Plunge (protrusion) Weld Cable Size Length 500' Max. Number of grounds (work piece leads) 2 (Two) Stud No. 1 2 Visual Acceptance Steven McCall Steven McCall Option #1 Bend Test Accepted 11-06-01 Accepted 11-06-01 POSITION Overhead Down hand 70 Angular Angle Iron - Inside Radius SHIELDING GAS Shielding Gas(es) Composition Flow Rate Option #2 Tension Test Side Hand X Degrees from normal Heel of Angle

N/A N/A N/A Option #3 Torque Test*

* Note: Torque test optional for threaded fasteners only. Mechanical Test Conducted by Arrow Inspection & Testing Inc.
Company

Date

11/6/2001

We, the undersigned certify that the statements in this record are correct and that the test welds were prepared, welded, and tested in accordance with the requirements of section 7 of ANSI/AWS D1.1, 2000 Structural Welding Cose-Steel.

Signed By
(Contractor / Applicator)

Title

Date

Welder Qualification Record


Company Name DJ Scheffler Inc. Supporting PQR # DJS-Studs-0001 Operator Name Waldemar Vizcarra #7204 Stud Material Mild Steel Material Specifications ASTM A108 Grade C 1015 Weld Base Diameter 5/8" Test No. DJS-Studs-WQR-Vizcarra Revision # 0 Date 11/6/2001 By Arrow Inspection & Testing Inc. Authorized By B. Becker Date 11/6/2001

BASE MATERIAL
Specification Alloy and Temper Group # II Coating Cleaning Method Decking Gage A572 Grade 50 Steel N/A Surface Condition HR CR N/A Wire Brush/Grinder N/A

SHAPE
Flat X Thickness Round Tube 0.72 Angle

FERRULE Part # Ferrule Description

104-053-014 5/8" @ Vertical Position

MACHINE DATA
Power Supply Make TRW/Nelson Welder Model 6500 Stud Gun Model TRW Series Welding Time Secs. 0.65 Cycles 36 5 % OCV Curret 1200 Polarity DCEN Lift Plunge (protrusion) Weld Cable Size Length 500' Max. Number of grounds (work piece leads) 2 (Two) Stud No. 1 2 Visual Acceptance Steven McCall Steven McCall Option #1 Bend Test Accepted 11-06-01 Accepted 11-06-01 POSITION Overhead Down hand 70 Angular Angle Iron - Inside Radius SHIELDING GAS Shielding Gas(es) Composition Flow Rate Option #2 Tension Test Side Hand X Degrees from normal Heel of Angle

N/A N/A N/A Option #3 Torque Test*

* Note: Torque test optional for threaded fasteners only. Mechanical Test Conducted by Arrow Inspection & Testing Inc.
Company

Date

11/6/2001

We, the undersigned certify that the statements in this record are correct and that the test welds were prepared, welded, and tested in accordance with the requirements of section 7 of ANSI/AWS D1.1, 2000 Structural Welding Cose-Steel.

Signed By
(Contractor / Applicator)

Title

Date

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Welder Paul Acevez Welding Procedure Specification No. MCMFCAW2G/07 Rev
Type of Welder

Name

Identification No.

Date
Record Actual Values Used in Qualification

10/24/2007

Qualification Range

Variables Process/Type Electrode (single or multiple) Current/Polarity Position Weld Progression Backing (YES or NO) [Table 4.11, Item (7)] Material/Spec. Base Metal Thickness: (Plate) Groove Fillet Thickness: (Pipe/tube) Groove Fillet Diameter: (Pipe) Groove Fillet Filler Metal [Table 4.11, Item (3)] Spec. No. Class F-No.

FCAW Single DCEN 3G Up Yes A36

SINGLE

1G,2G,3G,1F,2F,3F Up YES

1"

1/8" - UNLIMITED 1/8" - UNLIMITED PJP 1/8" - UNLIMITED 1/8" to Unlimited 24" 24"

N/A N/A N/A N/A ET71-8 AWS A5.20 10 N/A

Gas/Flux Type
Other

N/A

VISUAL INSPECTION Acceptable YES or NO Yes Type Result Guided Bend Test Results Type Result

SIDE SIDE

PASS PASS

Fillet TestFillet Result Appearance Size Fracture Test Root Penetration Macroetch (Describe the location, nature, and size of any crack or tearing of the specimen.) Inspected by Test Number Frank Gasco Test Number Organization Arrow Inspection and Testing Inc. Date

10/30/2007

We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, welded, and tested

in conformance with the requirements of Section 4 of AWS D1.1/D1 .1 M, Structural Welding CodeSteel.
Manufacturer or Contractor Authorized By

MCM Construction,Inc Authorized By

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Welder Jose Portillo Welding Procedure Specification No. MCMFCAW2G/07 Rev
Type of Welder

Name

Identification No.

Date
Record Actual Values Used in Qualification

10/24/2007

Qualification Range

Variables Process/Type Electrode (single or multiple) Current/Polarity Position Weld Progression Backing (YES or NO) [Table 4.11, Item (7)] Material/Spec. Base Metal Thickness: (Plate) Groove Fillet Thickness: (Pipe/tube) Groove Fillet Diameter: (Pipe) Groove Fillet Filler Metal [Table 4.11, Item (3)] Spec. No. Class F-No.

FCAW Single DCEN 3G Up Yes A36

SINGLE

1G,2G,3G,1F,2F,3F Up YES

1"

1/8" - UNLIMITED 1/8" - UNLIMITED PJP 1/8" - UNLIMITED 1/8" to Unlimited 24" 24"

N/A N/A N/A N/A ET71-8 AWS A5.20 10 N/A

Gas/Flux Type
Other

N/A

VISUAL INSPECTION Acceptable YES or NO Yes Type Result Guided Bend Test Results Type Result

SIDE SIDE

PASS PASS

Fillet TestFillet Result Appearance Size Fracture Test Root Penetration Macroetch (Describe the location, nature, and size of any crack or tearing of the specimen.) Inspected by Test Number Frank Gasco Test Number Organization Arrow Inspection and Testing Inc. Date

10/30/2007

We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, welded, and tested

in conformance with the requirements of Section 4 of AWS D1.1/D1 .1 M, Structural Welding CodeSteel.
Manufacturer or Contractor Authorized By

MCM Construction,Inc Authorized By

6515 Somerset Blvd. Paramount, CA 90723 562-634-0503 Office 562-634-0504 Fax


arrow.inspect@verizon.net

Welder/Operator Qualification Test Record


Welder Simon R. Reyes Welding Procedure Specification No. GMAW 001 Fillet Rev
Type of Welder

Name

Identification No.

Date
Record Actual Values Used in Qualification

SRR 6/11/2007

Qualification Range

Variables Process/Type Electrode (single or multiple) Current/Polarity Position Weld Progression Backing (YES or NO) [Table 4.11, Item (7)] Material/Spec. Base Metal Thickness: (Plate) Groove Fillet Thickness: (Pipe/tube) Groove Fillet Diameter: (Pipe) Groove Fillet Filler Metal [Table 4.11, Item (3)] Spec. No. Class F-No.

GMAW Single DCEP 3F Up N/A A36

Single

1F, 2F, 3F Up N/A

N/A 1/2" N/A N/A N/A N/A ER70S-6 AWS A5.18 Argon

N/A 1/8" to Unlimited N/A 1/8" to Unlimited N/A 1/8" to Unlimited

Gas/Flux Type
Other

Argon

VISUAL INSPECTION Acceptable YES or NO Yes Type Result Guided Bend Test Results Type Result

Fillet TestFillet Result Appearance Acceptable Size Fracture Test Root Penetration Acceptable Macro etch (Describe the location, nature, and size of any crack or tearing of the specimen.) Inspected by Test Number Rene Mora Test Number Organization Arrow Inspection and Testing Inc. Date

5/16" Acceptable Tear at Base metal #03-0607 6/11/2007

We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, welded, and tested

in conformance with the requirements of Section 4 of AWS Dl .1/Di .1 M, Structural Welding CodeSteel.
Manufacturer or Contractor Authorized By

Ace Fence

Authorized By