Catalog 2502/USA

Introduction Application

Directional Control Valves Series D3 Operation


Parkers D3 Series directional control valves consist of a four chamber style body, and a case hardened sliding spool. The spool is directly shifted by a variety of operators including: solenoid, lever, cam, or air pilot.

Parker D3 Series hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3 position. They are manifold mounted which conform to NFPAs D05/CETOP 5 mounting patterns. These valves were designed for industrial and mobile hydraulic applications which require high cycle rates, long life and high efficiency.

D3W Solenoid Operated Conduit Box Style

Easy access mounting bolts No tools required for coil removal 22 spool styles available Three electrical connection options AC & DC lights available CSA approved Available in low-watt DC version

D3W Solenoid Operated Hirschmann (DIN) Style

DIN Style (43650) Hirschmann Dual spade (SAE type 1B) lug style also available 22 spool styles available No tools required for coil removal Easy coil replacement AC & DC lights available CSA approved Available in low-watt DC version

D3W Soft Shift Tube


Repairable Override Assembly 9/16" Hex

Response Time Control Orifice** ** Orifice Removal Tool with Kit Part Number 1301661

Orifice** Removal Tool " Hex 5/32" Wrench Not Supplied

Hydraulics

A44

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Introduction Features

Directional Control Valves Series D3

Easy access mounting bolts 345 Bar (5000 PSI) pressure rating Flows to 40 GPM depending on spool Choice of four operator styles Rugged four land spools

Low pressure drop Phosphate finish body CSA approved and UL recognized (except manual operators) Proportional spool available

D3L Lever Operated

Spring return or detent styles available Heavy duty handle design High flow, low pressure drop design

D3A Air Operated

Low pilot pressure required 3.4 Bar (50 PSI) minimum Manual overrides standard High flow, low pressure drop design

D3C Cam Operated

Choice of 2 cam roller positions (D3C and D3D) Short stroke option High flow, low pressure drop design

Hydraulics

A45

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Introduction Application

Directional Control Valves Series D3 Operation


Parkers D3D Series directional control valves consist of a five chamber style body, and a case hardened sliding spool.

Parker D3D Series hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3 position. They are manifold mounted which conform to NFPAs D05/CETOP 5 mounting pattern. These valves were designed for industrial and mobile hydraulic applications which require high cycle rates, long life and high efficiency.

D3DW Solenoid Operated Hirschmann (DIN) Style

Easy access mounting bolts No tools required for coil removal 22 spool styles available Signal lights available CSA approved

Hydraulics

A46

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Technical Information D3 Quick Reference Data


Maximum Flow, LPM (GPM) 350 Bar (5000 PSI) w/o Malfunction Model Spool Symbol
A B

Directional Control Valves Series D3

Maximum Flow, LPM (GPM) 350 Bar (5000 PSI) w/o Malfunction Model Spool Symbol
A B

D3W

D3W*F

D3DW

D3W

D3W*F

D3DW

D3*1
P T

150 (40) 78 (20) 130 (33)


A B

D3*12
P T
A B

95 (24)

59 (15)

75 (19)

D3*2 D3*3 D3*4

P T
A B

150 (40) 78 (20) 115 (30) 150 (40) 78 (20) 120 (31) 150 (40) 59 (15) 130 (33)

D3*14
P T

50 (13) 59# (15) 70 (18)


A B

P T

D3*15
P T
A B

150 (40) 150 (40)


P T
A B

78 (20) 120 (31) 78 (20) 130 (33) 78 (20) 130 (33) N/A N/A N/A 120 (31) 120 (31) 75 (19)

A B

D3*16 D3*20
P T

P T
A B

D3*5 D3*6

P T

150 (40) 78 (20) 130 (33) 150 (40) 78 (20) 130 (33)

150 (40)
A B

A B

D3*21
P T A B

115 (30) 115 (30)


P T

P T
A B

D3*7
P T

50 (13) 59# (15) 70 (18)


A B

D3*22
A B

D3*8
P T
A B

50 (13) 59# (15) 39 (10)


P T A B

39 (10) 75 (19) 75 (19)

D3*26 D3*30

P T A B

115 (30) 39 (10)

D3*9 D3*10
P T

59# (15) N/A

59# (15) 75 (19) N/A N/A 130 (33) 130 (33)

P T
A B

115 (30)
A B

D3*81
P T
A B

115 (30) 115 (30)


P T

D3*11
P T

115 (30) 59# (15) 130 (33)

D3*82

Center or De-energized position is indicated by P, A, B & T port notation. 3000 PSI Max. 4300 PSI Max. # 1500 PSI Max.

D3L, D3A, D3C Quick Reference Data (Four Chamber Body Only)
Model Spool Symbol
A B

Maximum Flow, LPM (GPM) 350 Bar (5000 PSI) w/o Malfunction

Model

Spool Symbol
A B

Maximum Flow, LPM (GPM) 350 Bar (5000 PSI) w/o Malfunction

D3*1
P T
A B

150 (40) 150 (40)


P T

D3*20
P T
A B

150 (40) 115 (30)


P T

D3*2
A B

D3*26
A B

D3*4
P T
A B

150 (40) 50 (13)


P T

D3*30
P T
A B

39 (10) 115 (30)


P T

D3*8
A B

D3*81
A B

D3*9
P T

39 (10)

D3*82
P T

115 (30)

Center or De-energized position is indicated by A, B, P & T port notation.

Hydraulics

A47

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Performance Curves D3W-30 DC and AC Rectified Shift Limits

Directional Control Valves Series D3W

A
Supply Pressure

PSI Bar 5000

345

9, 30
300 4000 250 3000 200 150 100 1000 50

10, 21, 22, 26

8 12 7, 14

11, 81, 82

2000

8, 9, 30

20D, 26D 30D


10 2 4 20 6 30 8 40 10 12 50 14 60 16 70 18 20 80 22 90 24 100 26 110 28 30 120 32

1, 2, 3, 4, 5, 6, 15, 16, 20
130 34 140 36 38 150 40

LPM 0 GPM

Flow

Example: Determine the maximum allowable flow of a D3W Series valve (20D) at 150 Bar (2175 PSI) supply pressure. Locate the curve marked "20D". At 150 Bar (2175 PSI) supply pressure, the maximum flow is 98 LPM (25 GPM). At 345 Bar (5000 PSI), the flow is 72 LPM (18.5 GPM).
Important Notes for Switching LImit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow A and B ports. Unequal A and B port flows may reduce shift limits.

D3W-30 Low Watt DC and AC Rectified Shift Limits


PSI Bar

3000 200

Supply Pressure

2000

150

100 1000 50

7, 8, 9 11, 12, 14, 30

1, 2, 3, 5, 6, 15, 16, 20

LPM 0 GPM

10 1 2 3 4

20 5 6 7

30 8 9 10

40 11 12 13

50 14 15

60 16 17 18

70 19 20

Flow

Hydraulics

A48

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Performance Curves D3W-30 AC Shift Limits


PSI Bar 5000 345 300 4000

Directional Control Valves Series D3W

A
1, 3, 4, 5, 15, 16, 20, 30 6 3, 4, 5, 15, 16, 30 11 2 1, 6, 20

Supply Pressure

250 3000 200 150 100 1000 50

2000

9 7, 8, 14 20D, 30D
10 2 4 20 6 30 8 40 10 12 50 14 60 16 70 18 20 80 22 90 24 100 26 28

12

LPM 0 GPM

110 30

120 32

Flow

D3W-30 Soft Shift Limits


PSI Bar 5000

345
300

4000

12 12

Supply Pressure

1,2,5,6, 16,20,81

250 3000 200 150 100 1000 50

2000

7, 8, 9, 10, 14, 21, 22, 26, 82 20D, 26D, 30D

8, 9 3, 4, 11, 15, 30

LPM 0 GPM

10 2 4

20 6

30 8

40 10 12

50 14

60 16

70 18 20

80 22

90 24

100 26

110 28 30

120 32

130 34

140 36 38

150 40

Flow

Important Notes for Switching LImit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow A and B ports. Unequal A and B port flows may reduce shift limits.

Hydraulics

A49

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Performance Curves D3W-30 Soft Shift Response

Directional Control Valves Series D3DW

A
100

Shock Load
% of Maximum Shock

Response Time*
Signal to 95% spool stroke measured at 172 Bar (2500 PSI) and 65 LPM (17 GPM).
Soft Shift Option S4 S7
E D E D E D

80 60 40 20 0 Standard Valve Soft Shift "S7" Soft Shift "S4"

Energize 320 160

De-energize 550 370

* For reference only. Response time varies with flow, pressure and oil viscosity.

E = Energize D = De-energize

D3DW-40 Shift Limits


PSI Bar 5000

345
300

10, 26 8 12 9, 30 3, 21, 22

4000

Supply Pressure

250 3000 200

7, 14
2000 150 100 1000 50

20D, 26D, 30D

1, 4, 5, 6, 11, 12 15,16, 20, 81, 82


10 2 4 20 6 30 8 40 10 12 50 14 60 16 70 18 20 80 22 90 24 100 26 28 110 30 120 32 130 34 36

LPM 0 GPM

Flow

Important Notes for Switching LImit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow A and B ports. Unequal A and B port flows may reduce shift limits.

Hydraulics

A50

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Technical Information Pressure Drop vs. Flow


The table shown provides flow vs. pressure drop curve reference for D3 Series valves by spool type. The chart below demonstrates graphically the performance characteristics of the D3. The low watt coil and other design features of the standard D3W*****F accommodate a maximum flow of 78 L/M (20 GPM) at 207 Bar (3000 PSI).

Directional Control Valves Series D3


D3W/D3DW Pressure Drop Reference Chart
Curve Number Spool No. 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 20 21 22 26 30 PA 5 4 5 4 6 6 5 8 5 5 5 5 4 5 5 5 5 4 5 5 5 4 5 4 5 6 4 8 5 5 5 5 5 5 6 5 4 5 5 5 Shifted PB BT 2 1 2 3 2 2 2 7 4 2 2 1 3 2 2 1 2 AT 2 1 3 3 2 2 1 7 4 2 2 2 2 2 2 1 2 2 3 6 7 11 3 3 4 9 Center Condition (PT) (BA) (AB) (P-A) 3 4 9 3 2 2 10 3 (P-B) 3 2 3 10 2 (A-T) 1 1 1 10 10 1 (B-T) 1 1 1 10 10 1

Note: For 81 and 82 spools, consult factory.

Viscosity Correction Factor


Viscosity (SSU) % of P (Approx.) 75 93 150 111 200 119 250 126 300 132 350 137 400 141

Performance Curves
PSI Bar 350

Curves were generated using 110 SSU hydraulic oil. For any other viscosity, pressure drop will change per chart.

24

#11 #10

#9

#8 #7 #6 #5

280

19

Pressure Drop

210

15

#4 #3 #2

140

10

#1

70

LPM 0 GPM

10 2 4

20 6

30 8

40 10 12

50 14

60 16

70 18 20

80 22

90 24

100 26

110 28 30

120 32

130 34

140 36 38

150 40

Flow
Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Hydraulics

A51

Catalog 2502/USA

Technical Information General Description

Directional Control Valves Series D3W

The D3W Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position and conform to NFPAs D05/CETOP 5 mounting patterns.

AB

PT

Features

Worldwide, high flow, low pressure drop design. Mechanically tunable soft shift. 22 spools available including proportional. Repairable manual override for easy seal replacement. DC surge suppression available to protect electrical equipment. Three electrical connection options. AC & DC lights available. Easy access mounting bolts. Explosion proof availability. CSA approved. No tools required for coil removal. Rectified coils available for high flow AC applications.

Specifications
Interface Max. Operating Pressure NFPA D05, CETOP 5, NG 10 P, A, B: 345 Bar (5000 PSI) Standard CSA 207 Bar (3000 PSI)

Response Time (ms)


Signal to 95% spool stroke measured at 172 Bar (2500 PSI) and 75 LPM (20 GPM)
Solenoid Type AC DC Pull-In 21 110 Drop-Out 35 85

Tank: 103 Bar (1500 PSI) Standard CSA 103 Bar (1500 PSI)

Hydraulics

A52

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Technical Information Solenoid Ratings**


Insulation Allowable Deviation from rated voltage Armature Class H -10% to +15% Wet pin type

Directional Control Valves Series D3W

D3W*****F Solenoid Electrical Characteristics


Solenoid Code KF JF Nominal Volts/Hz 12 VDC 24 VDC In Rush Amps Holding Amps 3.00 0.75 Watts 18 18

** DC Solenoids available with optional molded metal oxide varistor (MOV) for surge suppression. Leadwire length 6 from coil face.

Based on nominal voltage @ 22C (72F)

D3W Solenoid Electrical Characteristics


Solenoid Code Y T E K J D Nominal Volts/Hz 120/60 110/50 240/60 220/50 24/60 24/50 12 VDC 24 VDC 120 VDC In Rush VA 298 294 288 288 290 381 Holding Nominal VA Watts (Ref) 95 102 96 101 77 110 3.00 1.50 0.30 32 32

D3W Rectified AC Solenoid Electrical Characteristics


Solenoid Code Y T Nominal Volts/Hz 120/60 110/50 240/60 220/50 120/60 110/50 240/60 220/50 In Rush Amps Holding Amps .37 .18 .18 .09 Watts 36 36 18 18

32 YF 36 36 36 TF

Based on nominal voltage @ 22C (72F)

DC holding amps.

Explosion Proof Solenoids


Explosion Proof Solenoid Ratings
U.L. (EU) C.S.A. CENELEC (ED) Class I, Div. 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G As defined by the N.E.C Complies with BASEEFA requirements for BS5501: Parts 1 and 5 Exd CENELEC EN50 D18, Group II B

Electrical Characteristics* ED and EU


Solenoid Code Y T K J D Nominal Volts/Hz 120/60 240/60 12 VDC 24 VDC 120 VDC In Rush VA 266 266 Holding Nominal VA Watts (Ref) 82 82 3.00 1.50 0.30 36 36 36 36 36

*Dual frequency not available on explosion proof coils. DC holding amps.

Hydraulics

A53

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Dimensions
Inch equivalents for millimeter dimensions are shown in (**)

Directional Control Valves Series D3W

Hirschmann, Double AC Solenoid

THIRD-ANGLE PROJECTION

107.7 (4.24) 90.0 (3.54) 86.2 (3.40) 69.5 (2.74) 36.0 (1.42) 89.8 (3.54)

12.0 (.47) 23.0 (.91) 58.0 (2.29)

21.5 (.85) 74.5 (2.93) 97.8 (3.85) 27.3 (1.08) 76.2 (3.00) 129.1 (5.09) 152.5 (6.01)

Hirschmann, Single AC Solenoid

THIRD-ANGLE PROJECTION

107.7 (4.24) 90.0 (3.54) 86.2 (3.40) 69.5 (2.74) 36.0 (1.42) See Note 21.5 (.85) 74.5 (2.93) 97.8 (3.85) 27.3 (1.08) 76.2 (3.00) 87.9 (3.45) 89.8 (3.54)

12.0 (.47) 23.0 (.91) 58.0 (2.29)

Note: 30.0mm (1.18") from bottom of bolt counterbore.


Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Hydraulics

A54

Catalog 2502/USA

Dimensions
Inch equivalents for millimeter dimensions are shown in (**)

Directional Control Valves Series D3W

Conduit Cavity, Double DC Solenoid

THIRD-ANGLE PROJECTION

90.0 (3.54) 86.2 (3.40) 69.5 (2.74) 36.0 (1.42)

12.0 (.47) 23.0 (.91) 58.0 (2.29) 21.5 (.85) 122.5 (4.83) 27.3 (1.08) 76.2 (3.00) 177.2 (6.98)

Conduit Cavity, Single DC Solenoid

THIRD-ANGLE PROJECTION

90.0 (3.54) 86.2 (3.40) 69.5 (2.74) 36.0 (1.42)

12.0 (.47) 23.0 (.91) 58.0 (2.29) 21.5 (.85) 122.5 (4.83)

27.3 (1.08) 76.2 (3.00) 87.9 (3.46)

Hydraulics

A55

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Dimensions
Inch equivalents for millimeter dimensions are shown in (**)

Directional Control Valves Series D3W

Conduit Box Extension, Double AC Solenoid


with Variation 6 (Manaplug) & Variation P (Extended Manual Override)

THIRD-ANGLE PROJECTION

15.9 (.63)

128.6 (5.07) 103.1 (4.06) 69.5 (2.74) 36.0 (1.42)

12.0 (.47) 23.0 (.91) 58.0 (2.29)

21.5 (.85) 97.8 (3.85) 112.2 (4.42)

27.3 (1.08) 74.1 (2.92) 76.2 (3.00) 152.5 (6.01) 166.9 (6.58)

Conduit Box Extension, Double DC Solenoid


with Variation 6 (Manaplug) & Variation P (Extended Manual Override)

THIRD-ANGLE PROJECTION

15.9 (.63)

128.6 (5.07) 103.1 (4.06) 69.5 (2.74) 36.0 (1.42)

12.0 (.47) 21.5 (.85) 23.0 (.91) 58.0 (2.29) 140.4 (5.53) 27.3 (1.08) 76.2 (3.00) 195.0 (7.68)

Hydraulics

A56

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Dimensions
Inch equivalents for millimeter dimensions are shown in (**)

Directional Control Valves Series D3W

Explosion Proof U.L. & CSA, Double Solenoid

THIRD-ANGLE PROJECTION

#18 AWG, 18 Inches Long, No Terminals, with UL Approval and Markings 1/2 Inch NPT Bolthole Centerline Reference

36.0 (1.42) 18.9 (0.74) 18.9 (0.74) Ref. Bolthole Centerline 12.0 Reference (0.47) 11.7 (0.46)

98.0 (3.86)

23.0 (0.91) 58.0 (2.29)

23.0 (0.91) 63.6 (2.51) 143.7 (5.66)

11.3 (0.44) 64.9 (2.56) 76.9 (3.03) 117.2 (4.62) 197.3 (7.77)

Explosion Proof CENELEC, Double Solenoid

THIRD-ANGLE PROJECTION

M20 x 1.5-6H Metric Thread

Bolthole Centerline Reference

134.7 (5.31) 103.6 (4.08)


36.0 (1.42) 18.9 (0.74) 11.6 (0.46)

18.9 (0.74) Ref. 23.0 (0.91) 58.1 (2.29) Bolthole Centerline Reference 154.1 (6.07) 23.0 (0.91) 75.6 (2.98)
11.3 (0.44) 64.9 (2.56)

12.1 (0.47)

76.7 (3.02)

207.7 (8.18)

Hydraulics

A57

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Dimensions
Inch equivalents for millimeter dimensions are shown in (**)

Directional Control Valves Series D3W

Conduit Box, Single DC Solenoid


with Variation I7 (Monitor Switch)

90.0 (3.54) 86.2 (3.40) 85.3 (3.36) 69.5 (2.74) 36.0 (1.42)

12.0 (.47) 23.0 (.91) 58.0 (2.29)

21.5 (.85) 122.5 (4.83)

27.3 (1.08) 76.2 (3.00) 176.2 (6.94)

Monitor Switch
(Variation I7)
This feature provides for electrical confirmation of the spool shift. This can be used in safety circuits, to assure proper sequencing, etc.
BLOCK DIAGRAM
Pin 2 (Input 24VDC) Inductor Pin 1 (Output N.O.) Regulator Pin 3 (Output N.C.)

Switch Data
Inductive switch requiring +18-42 volt input. Outputs A and B are opposite; one at 0 voltage, the other at input voltage. During switching, A and B outputs reverse. Provides 0.4A switching current.

Pin 4 (Ground Terminal) (Extended Position)

For repetitive switch power-up conditions, please consult factory.

Hydraulics

A58

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Accessories Conduit Box


(connection option K)
Interface 152.4 cm (6.0 inch) lead wires, 18 awg. NEMA 4 rating available (consult factory) Waterproof

Directional Control Valves Series D3W

Manaplug
(valve variations 6, 56, 1A, 1C)
Interface Brad Harrison Plug 3-Pin for Single Solenoid 5-Pin for Double Solenoid

Ground Wire #1 (Green) Solenoid (Negative) Wire #3 (Red/Black)

"B Solenoid (Positive) Wire #1 (Red/White) "A Solenoid (Positive) Wire #2 (Red)

"B Solenoid (Negative) Wire #5 (Red/Black) "A Solenoid (Negative) Wire #4 (Red/Yellow) Ground Wire #3 (Green)

Solenoid (Positive) Wire #2 (Red/White)

3-Pin Manaplug (Mini) with Lights


Single Solenoid Valves

5-Pin Manaplug (Mini) with Lights


Single and Double Solenoid Valves ("A" and "B" Solenoids Reversed for #8 and #9 Spools)

Hirschmann Plug with Lights


Pin #3 (Ground)

Pin #2 (Negative)

Pin #1 (Positive)

Face View of Plug

Hydraulics

A59

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Ordering Information

Directional Control Valves Series D3W

3
Basic Valve

W
Actuator Spool Style Seal Solenoid Voltage

Directional Control Valve

NFPA D05 CETOP 5 NG 10 Code Wet armature solenoid N V Description Nitrile Fluorocarbon

Code Code 1
P
A

Description

Symbol
A B

Code 14

Symbol
A B

T
B

P
A

T
B

2
P
A

15
T
B P A T B

E# 24/60 - 24/50 VAC Y 120/60 - 110/50 VAC T 240/60 - 220/50 VAC K 12 VDC J 24 VDC D# 120 VDC # High Watt Coil only.

3
P T

16
P
A

T
B

4
P
A

20*
T
B P
A

T
B

5
P T

21
P T

Code
A B

Description Single solenoid, 2 position, spring offset P to A and B to T in offset position


b
b A B

B*

6
P
A

22
T
B

P
A

T
B

7
P A T B

26*
P A T B

Double solenoid, 3 position, spring centered.


b

P
A

T
B a

Double solenoid, 2 position, detent


P T
A B

8*, 9**
P
A

30**
T
B P T

10
P A T B

81
P
A

Single solenoid, 2 position, spring centered. P to B and A to T when energized. Single solenoid, 2 position. Spring offset, energized to center. Position spool spacer on A side. P to A and B to T in spring offset position. Single solenoid, 2 position, spring offset. P to B and A to T in offset position. Single solenoid, 2 position. Spring centered. A side. P to A and B to T when energized. Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on B side. P to B and A to T in spring offset position. This condition varies with spool code

T
B

11
P T

82
P T

P
A B

T
a

H*

12
P T

P A

T B a

* 8, 20 & 26 spool have closed crossover ** 9 & 30 spool have open crossover Available only with high-watt rectified AC coils or high-watt DC coils

Valve schematic symbols are per NFPA/ANSI standards, providing flow P to A when energizing solenoid A. Note operators reverse sides for #8 and #9 spools. See installation information for details.

* Only spools 20, 26 & 30. Only spools 20 & 30.

Hydraulics

A60

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Ordering Information

Directional Control Valves Series D3W

A
Connector Package Solenoid Options Tube Options Manual Override Options Electrical Options Shift Response and Indication Approvals Variations Design Series NOTE: Not required when ordering.

Code

Description

Code Omit V#

Description

Code Omit 4 K

Description Standard Valve CSA Approval UL Recognition

C Conduit Cavity K Conduit Adaptor P Hirschmann w/Plug W* Hirschmann w/o Plug S*# Double Spade E Explosion Proof * Available only with J, K, Y (rectified) and T (rectified) voltages. Not CSA approved. # DC voltage only. Code Omit D F* U Coil High Watt Explosion Proof, EExd Low Watt Explosion Proof, UL/CSA

No Option Varistor Surge Suppressor Z AC Rectified # DC voltage only.

Code

Description

Omit Standard Valve S4 Soft Shift, 0.040" Orifice S7 Soft Shift, 0.070" Orifice I7 Monitor Switch* * Single solenoid models only. Not CE or CSA approved.

* Available only with J, K, Y (Rectified) and T (Rectified) voltages. Explosion proof coils are 60 Hz at standard voltage; dual rating not available.

Code Omit 5 6 7 56 57 1A 1B 1C 1D

Description Standard Valve Signal Lights Manaplug, Brad Harrison Mini Manaplug, Brad Harrison Micro (M12x1) Manaplug (Mini) with Lights Manaplug (Micro) with Lights (M12x1) Manaplug (Mini) Single Sol. 5-Pin Manaplug (Micro) Single Sol. 5-Pin (M12x1) Manaplug (Mini) Single Sol. 5-Pin w/Lights Manaplug (Micro) Single Sol. 5-Pin w/Lights (M12x1)

Code Omit

Description Low Pressure

Code Omit P R

Description Standard Tube Extended Manual Override Repairable Manual Override

Mounting Bolt Kits


UNC Bolt Kits for use with D3W Directional Control Valves & Manapak/Cartpak Number of Manapaks/Cartpaks @ 2.00" (50mm) thickness 1 2 BK141 3.50" BK61 4.25" BK142 5.50" BK62 6.25" Valve Weight: Single Solenoid: AC 4.3 kg (9.5 lbs) DC 5.3 kg (11.6 lbs) Double Solenoid: AC 5.0 kg (11.0 lbs) DC 7.3 kg (16.0 lbs) Standard Bolt Kit: BK98

0 D3W BK98 1.62" BK144 2.37"

3 BK143 7.50" BK63 8.25"

D3W with explosion proof coils NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to 16 Nm (12 ft-lbs)

Hydraulics

A61

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Ordering Information Manaplugs Electrical Plug (Mini)

Directional Control Valves Series D3W

E
Electrical

P
Plug

3
Valve Model Basic Configurations

D05 Pattern

Code 3 5

Description 3-Pin Plug 5-Pin Plug

Hirschmann Female Connector

E
Electrical

P
Plug

H
Hirschmann Style Connector Color

Code A B

Description Gray (Solenoid A) Black (Solenoid B)

Electrical Cords (Mini)

E
Electrical

C
Cord No. of Conductors Electrical Requirements

Code Omit 5

Description 3 Conductors (std) 5 Conductors

Code Omit 3 12

Description 6 feet (std) 3 feet 12 feet

Electrical Lights
Conduit Box Style

EL32
Electrical Light Voltage Code E Y T K J D Description 24/60 - 24/50 VAC 120/60 - 110/50 VAC 240/60 - 220/50 VAC 12 VDC 24 VDC 120 VDC

Hirschmann Style
(One light req'd per solenoid)

ELHI
Electrical Light Voltage Code EP YP TP KP JP DP Description 24/60 - 24/50 VAC 120/60 - 110/50 VAC 240/60 - 220/50 VAC 12 VDC 24 VDC 120 VDC

Hydraulics

A62

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Technical Information General Description


The D3DW Series directional control valves are highperformance, 5-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position and conform to NFPAs D05/CETOP 5 mounting patterns.

Directional Control Valves Series D3DW

AB

PT

Features

22 spools available including proportional. Repairable manual override for easy seal replacement. DC surge suppression available to protect electrical equipment. Easy access mounting bolts. CSA approved. No tools required for coil removal. High pressure tank line capability.

Specifications Response Time (ms)


Signal to 95% spool stroke measured at 175 Bar (2500 PSI) and 75 L/M (20 GPM)
Solenoid Type DC Pull-In 110 Drop-Out 85 Tank: 103 Bar (1500 PSI) Standard 207 Bar (3000 PSI) Optional CSA 103 Bar (1500 PSI) Interface Max. Operating Pressure NFPA D05, CETOP 5, NG 10 P, A, B: 345 Bar (5000 PSI) Standard CSA 207 Bar (3000 PSI)

Solenoid Ratings**
Insulation Allowable Deviation from rated voltage Armature Class H -10% to +15% Wet pin type

D3W Solenoid Electrical Characteristics


Solenoid Code K J D Nominal Volts 12 VDC 24 VDC 120 VDC In Rush Amps Holding Nominal Amps Watts (Ref) 3.00 1.50 0.30 36 36 36

** DC Solenoids available with optional molded metal oxide varistor (MOV) for surge suppression. Leadwire length 6 from coil face.

Hydraulics

A63

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Dimensions
Inch equivalents for millimeter dimensions are shown in (**)

Directional Control Valves Series D3DW

Hirschmann, Double DC Solenoid

THIRD-ANGLE PROJECTION

106.2 (4.18) 83.0 (3.27) 87.8 (3.46)

36.0 (1.42)

12.0 (0.47) 23.0 (0.91) 58.9 (2.29)

21.5 (0.85) 80.1 (3.16) 122.5 (4.83) 76.2 (3.00) 177.2 (6.98)

Hirschmann, Single DC Solenoid

THIRD-ANGLE PROJECTION

83.0 (3.27)

88.2 (3.48) See Note

36.0 (1.42)

12.0 (0.47) 23.0 (0.91) 40.5 (1.60) 58.0 (2.29) 122.5 (4.83)

21.5 (0.85) 76.2 (3.00) 87.9 (3.46)

Note: 30.0mm (1.18") from bottom of bolt counterbore.


Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Hydraulics

A64

Catalog 2502/USA

Dimensions
Inch equivalents for millimeter dimensions are shown in (**)

Directional Control Valves Series D3DW

Dual Spade, Single DC Solenoid


with Variation I7 (Monitor Switch)

96.1 (3.79) 83.0 (3.27) 88.2 (3.48) 85.3 (3.36)

36.0 (1.42)

12.0 (0.47) 23.0 (0.91) 40.5 (1.60) 58.0 (2.29) 122.5 (4.83) 21.5 (0.85) 76.2 (3.00) 176.2 (6.94)

Monitor Switch
(Variation I7)
This feature provides for electrical confirmation of the spool shift. This can be used in safety circuits, to assure proper sequencing, etc.
BLOCK DIAGRAM
Pin 2 (Input 24VDC) Inductor Pin 1 (Output N.O.) Regulator Pin 3 (Output N.C.)

Switch Data
Inductive switch requiring +18-42 volt input. Outputs A and B are opposite; one at 0 voltage, the other at input voltage. During switching, A and B outputs reverse. Provides 0.4A switching current.

Pin 4 (Ground Terminal) (Extended Position)

For repetitive switch power-up conditions, please consult factory.

Hydraulics

A65

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Ordering Information

Directional Control Valves Series D3DW

3
Basic Valve

D
Body

W
Actuator Spool Style Seal Solenoid Voltage

Directional Control Valve

NFPA D05 CETOP 5 NG 10 5-Chamber Body

Wet armature solenoid Code N V Description Nitrile Fluorocarbon

Code K J D Code 1
P T

Description 12 VDC 24 VDC 120 VDC

Symbol
A B

Code 14

Symbol
A B

P A

T B

2
P T

15
A B P A T B

Code B*

Description Single solenoid, 2 position, spring offset P to A and B to T in offset position


b
b A B

3
P
A

16
T
B P T

4
P T

20*
P T A B

Double solenoid, 3 position, spring centered.


b

P
A

T
B a

Double solenoid, 2 position, detent


P T

5
P T

21
P
A

T
B

6
P
A

22
T
B
P T

Single solenoid, 2 position, spring centered. P to B and A to T when energized. Single solenoid, 2 position. Spring offset, energized to center. Position spool spacer on A side. P to A and B to T in spring offset position. Single solenoid, 2 position, spring offset. P to B and A to T in offset position. Single solenoid, 2 position. Spring centered. A side. P to A and B to T when energized. Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on B side. P to B and A to T in spring offset position. This condition varies with spool code

P b A

T B

7
P A T B

26*
P A T B

P A B

T a

H*

8*, 9**
P
A

30**
T
B

P A

T B a

P A

T B

10
P T

81
P
A

P A

T B a

T
B

11
P A T B

82
P T

* Only spools 20, 26 & 30. Only spools 20 & 30.

12
P T

* 8, 20 & 26 spool have closed crossover ** 9 & 30 spool have open crossover Valve schematic symbols are per NFPA/ANSI standards, providing flow P to A when energizing solenoid A. Note operators reverse sides for #8 and #9 spools. See installation information for details.
Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Hydraulics

A66

Catalog 2502/USA

Ordering Information

Directional Control Valves Series D3DW

A
Connector Package Solenoid Options Tube Options Manual Override Options Electrical Options Shift Indication Approvals Variations Design Series NOTE: Not required when ordering.

Code

Description

Code Omit

Description No Option

P Hirschmann w/Plug W* Hirschmann w/o Plug S* Double Spade * Not available with signal lights. Not CSA approved.

Code

Description

Code Omit 5

Description Standard Valve Signal Lights

Code Omit

Coil High Watt

Omit Standard Valve I7* Monitor Switch * Single solenoid models only. Not CE or CSA approved.

Code Omit H

Description Low Pressure High Pressure Code Description

Code Omit P R

Description Standard Tube Extended Manual Override Repairable Manual Override

Omit Standard Valve 4* CSA Approval K UL Recognition * Not available with high pressure tube.

Mounting Bolt Kits


UNC Bolt Kits for use with D3DW Directional Control Valves & Manapak/Cartpak Number of Manapaks/Cartpaks @ 2.00" (50mm) thickness 1 2 BK141 3.50" BK61 4.25" BK142 5.50" BK62 6.25"

0 D3DW BK98 1.62" BK144 2.37"

3 BK143 7.50" BK63 8.25"

D3DW with explosion proof coils NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to 16 Nm (12 ft-lbs)

Valve Weight: Single Solenoid 5.3 kg (11.6 lbs) Double Solenoid 7.3 kg (16.0 lbs) Standard Bolt Kit: BK98

Hydraulics

A67

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Technical Information General Description

Directional Control Valves Series D3L

The D3L Series directional control valves are highperformance, 4-chamber, direct operated, lever controlled, 3 or 4-way valves. They are available in 2 or 3-position and conform to NFPAs D05/CETOP 5 mounting patterns.

A B

P T

Features

Spring return or detent styles available High flow, low pressure drop design Heavy duty handle design
Specifications
Mounting Pattern Maximum Pressure Maximum Flow Force Required to Shift Lever Operator NFPA D05, CETOP 5, NG 10 Operating: 345 Bar (5000 PSI) Tank Line: 34 Bar (500 PSI) See Quick Reference Chart 173 N (39 lbs)

Dimensions
Inch equivalents for millimeter dimensions are shown in (**)

Lever Operated D3L

THIRD-ANGLE PROJECTION

8.9 Full Shift 149.07 (5.873) 15.50 (0.611)

162.81 (6.415)

89.95 (3.544) 58.23 (2.294) See Note 36.00 (1.418)

174.45 (6.873)

35.00 (1.379) 70.00 (2.758)

Note: 30.0mm (1.18") from bottom of bolt counterbore.


Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Hydraulics

A68

Catalog 2502/USA

Ordering Information

Directional Control Valves Series D3L

D
Directional Control Valve

3
Basic Valve Operator Type & Location Spool Style Seal Compound Variations Design Series

NFPA D05 CETOP 5 NG10

Code N V

Description Nitrile Fluorocarbon Not Required When Ordering

Code L LB

Operator Type Lever (Standard) Lever (Alternate)

Operator Location (A or B End) For Valve Style B B A C B A D B A E A N/A H B A K B N/A N B A

Code

Description

Omit Standard I7* Monitor Switch * Not available on C, D or N Styles. Not CE or CSA approved.

Code 1

Symbol
A B

Code 20*

Symbol
A B

Code B*

Description Two position, spring offset. P to A and B to T in offset position.


A B
A B

P
A

T
B

2
P
A

30
T
B A

C
P
B

Three position, spring centered. Two position, detent.

P
A

T
B

4
P T

81
P T

D*
A B

T A B

8*
P A T B

82
P T

Two position, spring centered. P to B and A to T in shifted position. Two position, spring offset. P to B and A to T in offset position. Two position, spring centered. P to A and B to T in shifted position. Three position, detent.
P T

9
P T

H*

P A

T B

* 8 and 20 spools have closed crossover. 9 and 30 are open crossover.

P
A

T
B

Valve schematic symbols are per NFPA/ANSI standards, providing flow P to A when energizing operator A. Note operators reverse sides for #8 and #9 spools. See installation information for details.

* 20 and 30 spools only. This condition varies with spool code

Mounting Bolt Kits


UNC Bolt Kits for use with D3L Valves Directional Control Valves & Manapak/Cartpak Number of Manapaks/Cartpaks @ 2.00" (50mm) thickness 1 2 Valve Weight: 3.6 kg (8 lbs) Standard Bolt Kit: 3 BK98

0 D3L

BK98 BK141 BK142 BK143 1.62" 3.62" 5.62" 7.62" NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to 16 Nm (12 ft-lbs)

Hydraulics

A69

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Technical Information General Description

Directional Control Valves Series D3A

The D3A Series directional control valves are highperformance, 4-chamber, direct operated, air pilot controlled, 3 or 4-way valves. They are available in 2 or 3-position and conform to NFPAs D05/CETOP 5 mounting patterns.

AB

P T

Features

Low pilot pressure required 3.4 Bar (50 PSI) minimum Manual overrides standard High flow, low pressure drop design

Specifications
Mounting Pattern Maximum Pressure Maximum Flow Pilot Pressure NFPA D05, CETOP 5, NG 10 Operating: 345 Bar (5000 PSI) Tank Line: 34 Bar (500 PSI) See Quick Reference Chart Air Minimum 3.4 Bar (50 PSI) Air Maximum 6.9 Bar (100 PSI)

Response Time* (ms)


Signal to 95% spool stroke measured at 172 Bar (2500 PSI) and 160 LPM (20 GPM)

Air Operated
Shift Volume. The air pilot chamber requires a volume of 1.8 cc (.106 in.3) for complete shift from center to end. Pilot Piston. The pilot piston area is 506 mm2 (.785 in.2). Pilot piston stroke is 3.4 mm (.135 in.).

Pilot Pressure

Pull-In

Drop-Out

50 PSI 23.0 23.0 100 PSI 19.0 38.0 * Chart is for reference only. Response time will vary with pilot line size, length, air pressure and air valve flow capacity (Cv).

Hydraulics

A70

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Technical Information Dimensions


Inch equivalents for millimeter dimensions are shown in (**)

Directional Control Valves Series D3A

Air Operated, Double Pilot


134.3 (5.29) 121.1 (4.77)

A
67.1 (2.64)
THIRD-ANGLE PROJECTION

214.0 (8.43)

90.0 (3.55)

36.0 (1.42)

35.0 (1.38) 70.0 (2.76)

Air Operated, Single Pilot


79.51 (3.133) 101.81 (4.011)
THIRD-ANGLE PROJECTION

181.82 (7.164)

89.95 (3.544)

36.00 (1.418)

See Note

35.00 (1.379) 70.00 (2.758)

Note: 30.0mm (1.18") from bottom of bolt counterbore.


Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Hydraulics

A71

Catalog 2502/USA

Ordering Information

Directional Control Valves Series D3A

3
Basic Valve

A
Actuator Spool Style Seal Compound Variations Design Series

Directional Control Valve

NFPA D05 CETOP 5 NG 10

Code N V

Description Nitrile Fluorocarbon Not Required When Ordering

Code A

Description Air Operator Code Description Omit Standard I7* Monitor Switch * Available in B, E, H & K styles only. Not CE or CSA approved.

Code 1

Symbol
A B

Code 20*

Symbol
A B

P
A

T
B

2
P
A

30
T
B A

P
B

4
P T

81
P T

Code B#

Description Single operator, two position spring offset. P to A and B to T in offset position. Double operator, three position, spring centered. Double operator, two position, detent. Two position, spring centered. P to B and A to T in shifted position. Single operator, two position, spring offset. P to B and A to T in offset position.
A B
A B

8*
P A T B

82
P T

9
P T

* 8 and 20 spools have closed crossover. 9 and 30 are open crossover.

D#

E Valve schematic symbols are per NFPA/ANSI standards, providing flow P to A when energizing operator A. Note operators reverse sides for #8 and #9 spools. See installation information for details.

H#

P A

T B

Two position, spring centered. K P to A and B to T P T in shifted position. # B, D & H styles available with 20 and 30 spools only.

Mounting Bolt Kits


UNC Bolt Kits for use with D3A Valves Directional Control Valves & Manapak/Cartpak Number of Manapaks/Cartpaks @ 2.00" (50mm) thickness 1 2 Indicates air pilot This condition varies with spool code Valve Weight: 4.1 kg (9 lbs) Standard Bolt Kit: BK98

0 D3A

BK98 BK141 BK142 BK143 1.62" 3.62" 5.62" 7.62" NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to 16 Nm (12 ft-lbs)

Hydraulics

A72

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Technical Information General Description


The D3C and D3D Series directional control valves are high-performance, 4-chamber, direct operated, cam controlled, 3 or 4-way valves. They are available in 2position and conform to NFPAs D05/CETOP 5 mounting patterns.

Directional Control Valves Series D3C and D3D

Features

Choice of 2 cam roller positions (D3C and D3D) Short stroke option High flow, low pressure drop design
Specifications
Mounting Pattern Maximum Pressure Maximum Flow Force Required to Shift Maximum Cam Angle NFPA D05, CETOP 5, NG 10 Operating: 345 Bar (5000 PSI) Tank Line: 34 Bar (500 PSI) See Quick Reference Chart 107 N (53 lbs.) 30

Dimensions
Inch equivalents for millimeter dimensions are shown in (**)

Cam Operated

70.0 (2.76) 35.0 (1.38) 12.0 (0.47)

Valve Type Standard Valve B5 Short Stroke

Pre-Travel 1.75 (0.07) 0 (0)

Full Spool Over-Travel Travel 5.75 (0.23) 4.00 (0.16) 2.03 (0.08) 2.03 (0.08)

Over-Travel Full Spool Travel Pre-Travel 87.3 (3.44)

36.0 (1.42)

See Note 23.12 (0.91) 79.3 (3.13) 88.8 (3.50) 190.7 (7.51)

Note: 30.0mm (1.18") from bottom of bolt counterbore.


Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Hydraulics

A73

Catalog 2502/USA

Ordering Information

Directional Control Valves Series D3C and D3D

3
Basic Valve Actuator Spool Style Seal Compound Code N V Description Nitrile Fluorocarbon Not Required When Ordering Variations Design Series

Directional Control Valve

NFPA D05 CETOP 5 NG 10

Code C D

Description Cam (90 to mounting surface) Cam parallel to mounting surface

Code

Description

Omit Standard B5 Short Stroke I7* Monitor Switch * Not CE or CSA approved.

Code 20*

Symbol
A B

Code B

Description Two position, spring offset operator at A port end. Two position, spring offset operator at B port end.
A B
A B

30
P T

* 20 spool has closed crossover. 30 spool has open crossover.

Valve schematic symbols are per NFPA/ANSI standards, providing flow P to A when energized. Note operators reverse sides for #8 and #9 spools. See installation information for details.

Mounting Bolt Kits


UNC Bolt Kits for use with D3C & D3D Valves Directional Control Valves & Manapak/Cartpak Number of Manapaks/Cartpaks @ 2.00" (50mm) thickness 1 2 Valve Weight: 3.6 kg (8 lbs) Standard Bolt Kit: 3 BK98

0 D3C, D3D

BK98 BK141 BK142 BK143 1.62" 3.62" 5.62" 7.62" NOTE: All bolts are SAE grade 8, 1/4-20 UNC-2A thread, torque to 16 Nm (12 ft-lbs)

Hydraulics

A74

Parker Hannifin Corporation Hydraulic Valve Division Elyria, Ohio 44035 USA

Catalog 2502/USA

Installation Information
Fluid Recommendations
Premium quality hydraulic oil with a viscosity range between 150-250 SSU (32 -54 cst) at 38 C (100F) is recommended. The absolute operation viscosity range is from 80-1000 SSU (16-220 cst). Oil should have maximum anti-wear properties and rust and oxidation treatments.

Directional Control Valves Series D3*


Flow Path Data

D3*
Operator B
T A

P B T

Operator A

Fluids and Seals


Valves using synthetic, fire-resistant fluids require special seals. When phospate ester or its blends are used, FLUOROCARBON seals are required. Waterglycol, water-in-oil emulsions, and petroleum oil may be used with NITRILE seals.

*Note: On valves with 8 or 9 spool, A and/or B operators reverse sides. Flow paths remain the same as viewed from top of valve.

Temperature Recommendation
Recommended oil temperature: -7 to +71C (-20 to +160F)

Double Solenoid. With solenoid A energized, flow path is PA and BT. When solenoid B is energized, flow path is PB and AT. The center condition on a spring-centered valve exists when both coils are deenergized, or during a complete shift, as the spool passes through center. Detent and Spring Offset. The center condition exists on detent and spring offset valves only during spool crossover. To shift and hold a detented spool, only a momentary energizing of the solenoid is necessary. The minimum duration of the signal is aproximately 0.13 seconds for both AC and DC voltages. This position will be held provided the spool center line is in a horizontal plane, and no shock or vibration is present to displace the spool. Single Solenoid. Spring offset valves can be ordered in six styles: B, E, F, H, K and M. Flow path data for the various styles are described in the order chart. Lever Operated (on B end) Pull lever away from valve Push lever toward valve PA; BT PB; AT

Filtration
For maximum valve and system component life, the system should be protected at a contamination level not to exceed 125 particles greater than 10 microns per milliliter of fluid. (SAE Class 4 or better, ISO Code 16/13).

Tank Line Surges


If several valves are piped with a common tank line, flow surges in the line may cause unexpected spool shift. Detent style valves are most susceptible to this. Separate tank lines should be used when line surges are expected in an application.

Note: Reverse with a #8 or #9 spool.

Recommended Mounting Position


Valve Type Detent (Solenoid) Spring Offset Spring Centered Recommended Mounting Position Horizontal Unrestricted Unrestricted

Electrical Failure
Should electric power fail, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop simultaneously, machine actuators may continue to function in an undesirable manner or sequence.

Silting
Silting can cause any sliding spool valve to stick and not spring return, if held shifted under pressure for long periods of time. The valve should be cycled periodically to prevent sticking.

Loss of Pilot Pressure (D3A)


Should a loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. Detented valves will remain in the last position held. If main hydraulic flow does not simultaneously stop, machine actuators may continue to function in an undesirable manner or sequence.

Single Pass Operation


Valve flow ratings are for double pass operation (with equal flow in both paths). When using these components in single pass applications, flow capabilities may be reduced. Consult your local Parker representative for details.

Torque Specifications
Torque values recommended for the bolts which mount the valve to the manifold or subplate are as follows: 1/4-20 thread (M6x1) torque 16.0 Nm (12 ft-lbs).