Beruflich Dokumente
Kultur Dokumente
PMX-00-B
Automation Simplified
Possible Applications :
Port Multiplexer allows the connection of two field devices to a single controller (PLC) over a serial link on time sharing basis with same protocols. Some of possible Port Multiplexer applications include : 1. HMI and SCADA Communication / PLC Programming to PLC.
Operator interface (Master 2) Port Multiplexer X Protocol X Protocol
PLC
PLC
PLC
Other Items required for Port Multiplexer configuration: 1. Port Multiplexer unit 2. Port Multiplexer Configuration Cable 3. Port Multiplexer Setup Software 4. Devices with communication cables
Communication Ports :
Port Multiplexer has two identical communication ports Master1 and Master2 and third port to connect a PLC. Master ports are compatible to RS232 signal levels and PLC port supports RS232 / RS422 / 2 or 4 wire RS485 / CMOS signal levels. Pin details are given below: Pin Signals PLC Port Master 2 Master 1 1 RS 232 TXD 2 RS 232 RXD 5 5 5 5 3 GND 9 9 Signal Ground 9 9 Signal Ground NC NC 4 4 8 8 NC NC C_CTS 3 NC 4 TX+ 3 7 7 RXD (RS232C) RXD (RS232C) C_RTS 2 NC 2 6 6 TXD (RS232C) TXD (RS232C) NC 1 5 RX+ 1 NC 6 6 C_DCD 1 NC 1 6 TX7 RX 87654321 DB9 Female 8 CMOS TXD DB9 Female
*Do not use pin no. 6 of either of the Master ports. **Refer Portmultiplexer user manual for specific cable details
PLCs Supported :
Port Multiplexer currently supports following PLC / Protocols: AB Df1 Full Duplex (Micrologix / SLC5/0x / PLC5/30) IDEC Micro3 Modbus RTU Aromat FP Series (Mewtocol) Modbus ASCII Omron Host Link
Following PLCs / Protocols can also be supported in Port Multiplexer on request: ABB Cegelec Alspa series Delta DVP Series Honeywell J-BUS LG MasterK 80S-300S Mitsubishi FX Siemens Step-7 Micro Taian TP02 Series Toshiba T series (Prog Port) USS Protocol AB DH485 (SLC5/0x series) Baldor Drives CEGELEC Crouzet Entertron GE Fanuc Series 90-30, VersaMax IDEC MicroSmart, IDEC Open Net Idec Micro 1 / FA2Jr PLCs Keyence KV Series Koyo Messung XMP-8 / NEXGEN 4000 / NEXGEN 5000 Modbus Slave Omron NT Link Siemens-S7-200 Series Siemens S7-300 Series Telemecanique TSX07/37/57 Telemecanique 17, 47 & 67 Series Toshiba T1, T2, T3, V series (Link Port) Twido Yaskawa
We welcome an opportunity to develop new, custom drivers and customization of Port Multiplexer products.
Specifications :
Power : + 24 V DC 10%, 100mA max LEDs : 4 LEDs for status indication Communication Ports : 3 Communication ports (Isolation between communication ports and Power supply, through DC-DC coupler is 1 KV) PLC Port : Connects to PLC Master 1 : Connects to Master Device 1 Master 2 : Connects to Master Device 2 Temperature : Operating : 0O to 50OC Storage : -20O to 80OC Humidity : 10% to 90% (Non condensing) Mounting Dimensions (DIN rail) Weight Approvals Immunity to ESD Immunity to Transients Immunity to Radiated RF Immunity to Conducted RF Emissions : DIN rail or back panel mounting : 105mm(L) X 40mm(D) X 51mm(W) : 125 gm approx. : CE, CSA : Level 3 as per IEC1000-4-2 : Level 3 as per IEC1000-4-4 : Level 3 as per IEC1000-4-3 : Level 3 as per IEC1000-4-6 : En55011 CISPR A
Ordering Options :
Example: Model + 24 V DC External Supply Black Case
* Units are also available with Gray case. Replace sufix B by G in unit part number for Gray case.
PMX-00-B
Dimensions :
40 51
Master 1
OK PLC1 MASTER1 MASTER2
PLC Port
105
C US LR 109782-2
DC+ DCEARTH
PMX-00-B