Sie sind auf Seite 1von 60

Cable & Connectors

Cable & Connectors Contents Page

About Cable & Connectors


The cables and connectors listed in this section meet the highest standards of quality control in the industry. All trunk and feeder cables are specified to at least 1 GHz, 30 dB structural return loss (SRL); all drop cables are specified to 1 GHz, 20 dB SRL, and all connectors are specified to 1 GHz. These products are utilized extensively in all cable television systems including private homes, banks, factories, hotels, motels, hospitals, apartment complexes, government and military facilities, and many more areas of application. Telewire Supply provides products from such quality manufacturers to the cable TV industry as Belden, Comm/Scope, Gilbert, LRC, Amphenol, Cablecom and many more. Equipment is regionally warehoused across the country, providing for complete system fulfillments and on-time delivery. This section is devised as a buyer's guide only and is not intended to be a design or installation guide.

Quality Policy
Telewire Supply is dedicated to meeting the requirements of our customers by providing Quality Products and Services on a timely basis.

In this section
Item . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page About Trunk Cable . . . . . . . . . . . . . . . . . . . . . . . . . .G2 .500 Trunk Cable . . . . . . . . . . . . . . . . . . . . . . . .G3-G4 .625 Trunk Cable . . . . . . . . . . . . . . . . . . . . . . . .G5-G6 .750 Trunk Cable . . . . . . . . . . . . . . . . . . . . . . . .G7-G8 .875 Trunk Cable . . . . . . . . . . . . . . . . . . . . . . . . . . .G9 1.00 Trunk Cable . . . . . . . . . . . . . . . . . . . . . . . . . .G10 .540 QR Trunk Cable . . . . . . . . . . . . . . . . . . . . . . .G11 Gilbert Quick Reference . . . . . . . . . . . . . . . .G27-G28 LRC Quick Reference . . . . . . . . . . . . . . . . . .G29-G30 .412 Connectors . . . . . . . . . . . . . . . . . . . . . . .G32-G33 .500 Connectors . . . . . . . . . . . . . . . . . . . . . . .G34-G35 .540 QR Connectors . . . . . . . . . . . . . . . . . . . . . . .G36 .625 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . .G37 .650 MC2 Connectors . . . . . . . . . . . . . . . . . . . . . . .G38 .700 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . .G38 .715 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . .G39 .750 Connectors . . . . . . . . . . . . . . . . . . . . . . .G40-G41 .840, .860 Connectors . . . . . . . . . . . . . . . . . . . . . .G42 .875, 1.00 Connectors . . . . . . . . . . . . . . . . . . . . . .G43 1.125 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . .G44 Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G45-G49 Heat Shrink . . . . . . . . . . . . . . . . . . . . . . . . . .G50-G51 Digicon Connector . . . . . . . . . . . . . . . . . . . . . . . . .G52 EZF Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . .G53 "F" Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . .G54 F-81 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . .G55 50 Ohm Connectors . . . . . . . . . . . . . . . . . . . . . . . .G56 Drop Cable Cross Reference . . . . . . . . . . . .G57-G59
EAST: Rockaway, NJ WEST: Santa Ana, CA 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

.715 QR Trunk Cable . . . . . . . . . . . . . . . . . . . . . . .G12 .860 QR Trunk Cable . . . . . . . . . . . . . . . . . . . . . . .G13 1.125 QR Trunk Cable . . . . . . . . . . . . . . . . . . . . . .G14 Trunk Cable Weights . . . . . . . . . . . . . . . . . . . . . . .G15 Trunk Cable Information . . . . . . . . . . . . . . . . . . . .G16 Drop Cable Specifications . . . . . . . . . . . . . . .G17-G19 RG59 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G20 RG6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G21 RG7, RG11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G22 Wireless/DBS Cable . . . . . . . . . . . . . . . . . . . . . . . .G23 Headend Cables . . . . . . . . . . . . . . . . . . . . . . . . . .G24 Audio / Telephone Cable . . . . . . . . . . . . . . . . . . . .G25 Connector Types . . . . . . . . . . . . . . . . . . . . . . . . . .G26
SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288

G1

1996 TELEWIRE SUPPLY

Cable & Connectors Trunk Cables

Trunk Cables COMM/SCOPE


Description The application of coaxial cables to underground installations should be undertaken with caution because of the many hazards existing that can damage the cable both during and after placement. These hazards are also a major consideration in selecting the cable for underground use. Any vehicle that can prevent damage to the aluminum shield and center conductor should be a requirement, not an option. Some forms of damage could be cuts in the jacket caused by sharp rocks or debris, dents caused by rocks or rough handling during installation, and/or corrosion caused by moisture and corrosive elements in the ground. There are several styles of coaxial cables available from which to select the best design for each application. The following is a description of cable design from most protection to least protection. JACASS Polyethylene jacket, steel armor, flooding compound, polyethylene jacket, Migra-Heal flooding compound, aluminum conductor, dielectric adhesive (optional), dielectric, Double Clad conductor treatment and center conductor.
Cable Guard

Prefixes
P3 75 500, 540, 625, 750, 860, 875, 1000, 1125 QR Parameter III impedance trunk and feeder cable series Quantum Reach

Suffixes
J A CA SS SP M 109, 134, 250 P R Cable Guard polyethylene jacket armor copper clad aluminum center conductor Migra-Heal flooding compound asphaltic flooding compound messenger messenger size foamed teflon dielectric, plenum listed riser listed shock absorbing compartmentalized cell jacket

JCASS

Polyethylene jacket with shock absorbing compartmentalized cells, Migra-Heal flooding compound,aluminum conductor, dielectric adhesive, dielectric, Double Clad conductor treatment and center conductor. Polyethylene jacket, Migra-Heal flooding compound, aluminum conductor, dielectric adhesive(optional), dielectric, Double Clad conductor treatment and center conductor. Polyethylene jacket, asphalticflooding compound, aluminum conductor, dielectric adhesive (optional), dielectric, Double Clad conductor treatment and centerconductor. Polyethylene jacket, aluminum conductor, dielectric adhesive (optional), dielectric, Double Clad conductor treatment and centerconductor Aluminum conductor, dielectric adhesive (optional), dielectric, Double Clad conductor treatment and center conductor

Packaging Information Standard lengths


Parameter III, Cable Guard and Plenum .500 in. (12.7mm) .625 in. (15.8mm) 2,400 ft. (732 meters) 2,400 ft. (732 meters) 2,500 ft. (762 meters) 2,500 ft. (762 meters) 2,400 ft. (732 meters) 3,700 ft. (1128 meters) 3,000 ft. (914 meters) 2,700 ft. (823 meters) 3,000 ft. (914 meters)

JCASS

.750 in. (19.1mm) .875 in. (22.2mm) 1.00 in. (25.4mm) Quantum Reach .540 in. (13.72mm) .715 in. (18.16mm) .860 in. (21.84mm) 1.125 in. (28.58mm)

JCASP

JCA

All cable products 100% sweep tested. Each shipment shall be standard lengths 10%.

CA

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G2

Cable & Connectors Trunk Cable

.500 Parameter III Series Copper Clad Aluminum Sheath COMM /SCOPE

Bare Copper clad aluminum center conductor; expanded polyethylene dielectric; solid aluminum sheath; center conductor 0.111" (2.82mm) nominal; nom. O.D. 0.500" (12.70mm).

Cable Guard Jacketed with Flooding Compound Similar in construction to P3 75-500JCASS. The unique jacket design is a medium density polyethylene material .125" thick consisting of a 30 mils inner jacket, 75 mils high webbed air cells and a 30 mils outer jacket.

Jacketed Similar in construction to P3 75-500CA, except with 0.030" (0.76mm) outer jacket of black medium density polyethylene. Nominal O.D. 0.560" (14.22mm).

Jacketed with Steel Armor Similar to P3 75-500JCASS, except with 0.006" (0.15mm) corrugated chrome plated steel armor applied longitudinally, coated on outside with 0.002" (0.05mm) heat sealable film which bonds to outer jacket and seals edges to form an effective moisture barrier and provide mechanical protection. Nominal O.D. 0.715" (18.16mm).

Jacketed with Flooding Compound Similar in construction to P3 75-500JCA, except with MigraHeal compound between jacket and aluminum sheath

Jacketed with Steel Messenger Similar to P3 75-500JCA, except with "Figure 8" construction with 0.109" (2.77mm) galvanized steel messenger.

Ordering Information Order No.


CSP 202204 CSP 202205 CSP 202206 CSP 202207 CSP 202208 CSP 202209

Mfg. No.
P3 75-500CA P3 75-500JCA P3 75-500JCASS P3 75-500JCASSCG P3 75-500JACASS P3 75-500JCAM109

Description
Bare Jacketed Jacketed with Flooding Compound Cable GuardJacketed with Flooding Compound Jacketed with Steel Armor & Flooding Compound Jacketed with Steel Messenger

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G3

1996 TELEWIRE SUPPLY

Cable & Connectors Trunk Cable - .500PIII Series

.500 Parameter III Series Copper Clad Aluminum Sheath COMM /SCOPE
Physical Dimensions
Center Conductor Diameter Nominal Diameter Over Dielectric Diameter Over Outer Conductor 0.111" 0.001" (2.82mm 0.03mm) 0.450" (11.43mm) 0.500 0.007" (12.70mm 0.18mm) 0.025" (0.64mm) 0.560" (14.22mm) 0.030" (0.76mm) 0.635" (16.13mm) 0.008" (0.20mm) 0.715" (18.16mm) 0.040" (1.02mm) 0.109" (2.77mm)

Attenuation @ 68F (20C)


Frequency (MHz) 5 30 45 50 55 83 108 150 181 193 Maximum (db/100 ft.) 0.16 0.40 0.49 0.52 0.54 0.66 0.75 0.90 1.00 1.03 1.09 1.11 1.20 1.24 1.31 1.37 1.43 1.47 1.53 1.57 1.63 1.73 1.82 1.93 2.17 2.34 2.52 Maximum (db/100 m) 0.52 1.31 1.61 1.71 1.77 2.17 2.46 2.95 3.28 3.38 3.58 3.64 3.94 4.07 4.30 4.49 4.69 4.82 5.02 5.15 5.35 5.67 5.97 6.33 7.12 7.68 8.27

Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Nominal Diameter Over Corrugated Armor Nominal Shield Thickness Nominal Diameter Over Outer Jacket Nominal Thickness of Outer Jacket Diameter of Steel Messenger

Mechanical Characteristics
Minimum Bending Radius Without Armor With Armor Pulling Tension Minimum Breaking Strength of Messenger 8.0" (20.3cm) 10.5" (26.7cm) 200 lbs. (91 kg) 1,800 lbs. (816 kg)

211 220 250 270 300 325

Electrical Characteristics
Capacitance Impedance Velocity of Propagation 15.3 1.0 pf/ft. (50 3 nf/km) 75 2 ohms 87%

350 375 400 425 450 500 550 600 750 865 1000

Maximum of DC Resistance @ 68F (20C) Inner Conductor 1.35 ohms/1000 (4.40 ohms/km) Outer Conductor 0.37 ohms/1000 (1.24 ohms/km) Loop 1.72 ohms/1000 (5.64 ohms/km)

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G4

Cable & Connectors Trunk Cable

.625 Parameter III Series Copper Clad Aluminum Sheath COMM /SCOPE

Bare Copper clad aluminum center conductor; expanded polyethylene dielectric; solid aluminum sheath; center conductor 0.137" (3.48mm) nominal; nom. O.D. 0.625" (15.88mm).

Cable Guard Jacketed with Flooding Compound Similar in construction to P3 75-625JCASS. The unique jacket design is a medium density polyethylene material .125" thick consisting of a 30 mils inner jacket, 75 mils high webbed air cells and a 30 mils outer jacket. Nominal O.D. 0.875" (22.25mm).

Jacketed Similar in construction to P3 75-625CA, except with 0.030" (0.76mm) outer jacket of black medium density polyethylene. Nominal O.D. 0.685" (17.40mm).

Jacketed with Steel Armor Similar to P3 75-625JCASS, except with 0.006" (0.15mm) corrugated chrome plated steel armor applied longitudinally, coated on outside with 0.002" (0.05mm) heat sealable film which bonds to outer jacket and seals edges to form an effective moisture barrier and provide mechanical protection. Nominal O.D. 0.715" (18.16mm).

Jacketed with Flooding Compound Similar in construction to P3 75-625JCA, except with Migra-Heal compound between jacket and aluminum sheath.

Jacketed with Steel Messenger Similar to P3 75-625JCA, except with "Figure 8" construction with 0.109" (2.77mm) galvanized steel messenger.

Ordering Information Order No.


CSP 202210 CSP 202211 CSP 202212 CSP 202213 CSP 202214 CSP 202215

Mfg. No.
P3 75-625CA P3 75-625JCA P3 75-625JCASS P3 75-625JCASSCG P3 75-625JACASS P3 75-625JCAM109

Description
Bare Jacketed Jacketed with Flooding Compound Cable GuardJacketed with Flooding Compound Jacketed with Steel Armor & Flooding Compound Jacketed with Steel Messenger

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G5

1996 TELEWIRE SUPPLY

Cable & Connectors Trunk Cable

.625 Parameter III Series Copper Clad Aluminum Sheath COMM /SCOPE
Physical Dimensions
Center Conductor Diameter Nominal Diameter Over Dielectric Diameter Over Outer Conductor 0.137" 0.001" (3.48mm 0.03mm) 0.563" (14.30mm) 0.625 0.006" (15.88mm 0.18mm) 0.031" (0.79mm) 0.685" (17.40mm) 0.030" (0.76mm) 0.755" (19.18mm) 0.008" (0.20mm) 0.835" (21.21mm) 0.040" (1.02mm) 0.109" (2.77mm)

Attenuation @ 68F (20C)


Frequency (MHz) 5 30 45 50 55 83 108 150 181 193 Maximum (db/100 ft.) 0.13 0.34 0.41 0.44 0.46 0.57 0.65 0.77 0.85 0.88 0.92 0.94 1.00 1.05 1.10 1.15 1.20 1.23 1.28 1.32 1.35 1.43 1.50 1.59 1.78 1.93 2.07 Maximum (db/100 m) 0.52 1.31 1.61 1.71 1.77 2.17 2.46 2.95 3.28 3.38 3.58 3.64 3.94 4.07 4.30 4.49 4.69 4.82 5.02 5.15 5.35 5.67 5.97 6.33 7.12 7.68 8.27

Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Nominal Diameter Over Corrugated Armor Nominal Shield Thickness Nominal Diameter Over Outer Jacket Nominal Thickness of Outer Jacket Diameter of Steel Messenger

Mechanical Characteristics
Minimum Bending Radius Without Armor With Armor Pulling Tension Minimum Breaking Strength of Messenger 9.0" (22.9cm) 11.5" (29.2cm) 295 lbs. (134 kg) 1,800 lbs. (816 kg)

211 220 250 270 300 325

Electrical Characteristics
Capacitance Impedance Velocity of Propagation 15.3 1.0 pf/ft. (50 3 nf/km) 75 2 ohms 87%

350 375 400 425 450 500 550 600 750 865 1000

Maximum of DC Resistance @ 68F (20C) Inner Conductor 0.84 ohms/1000 (2.76 ohms/km) Outer Conductor 0.23 ohms/1000 (0.75 ohms/km) Loop 1.07 ohms/1000 (3.51 ohms/km)

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G6

Cable & Connectors Trunk Cable

.750 Parameter III Series Copper Clad Aluminum Sheath COMM /SCOPE

Bare Copper clad aluminum center conductor; expanded polyethylene dielectric; solid aluminum sheath; center conductor 0.169" (4.29mm) nominal; nom. O.D. 0.750" (19.1mm).

Cable Guard Jacketed with Flooding Compound Similar in construction to P3 75-750JCASS. The unique jacket design is a medium density polyethylene material .125" thick consisting of a 30 mils inner jacket, 75 mils high webbed air cells and a 30 mils outer jacket.

Jacketed Similar in construction to P3 75-750CA, except with 0.035" (0.90mm) outer jacket of black medium density polyethylene. Nominal O.D. 0.820" (20.83mm).

Jacketed with Steel Armor Similar to P3 75-750JCASS, except with 0.006" (0.15mm) corrugated chrome plated steel armor applied longitudinally, coated on outside with 0.002" (0.05mm) heat sealable film which bonds to outer jacket and seals edges to form an effective moisture barrier and provide mechanical protection. Nominal O.D. 1.00" (25.40mm).

Jacketed with Flooding Compound Similar in construction to P3 75-5750JCA, except with Migra-Heal compound between jacket and aluminum sheath

Jacketed with Steel Messenger Similar to P3 75-750JCA, except with "Figure 8" construction with 0.250" (6.35mm) galvanized steel messenger.

Ordering Information Order No.


CSP 202216 CSP 202217 CSP 202218 CSP 202219 CSP 202220 CSP 202221

Mfg. No.
P3 75-750CA P3 75-750JCA P3 75-750JCASS P3 75-750JCASSCG P3 75-750JACASS P3 75-750JCAM250

Description
Bare Jacketed Jacketed with Flooding Compound Cable GuardJacketed with Flooding Compound Jacketed with Steel Armor & Flooding Compound Jacketed with Steel Messenger

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G7

1996 TELEWIRE SUPPLY

Cable & Connectors Trunk Cable

.750 Parameter III Series Copper Clad Aluminum Sheath COMM /SCOPE
Physical Dimensions
Center Conductor Diameter Nominal Diameter Over Dielectric Diameter Over Outer Conductor 0.169" 0.001" (4.29mm 0.03mm) 0.678" (17.22mm) 0.750 0.010" (19.1mm 0.25mm) 0.036" (0.91mm) 0.820" (20.83mm) 0.035" (0.90mm) 0.920" (23.37mm) 0.008" (0.20mm) 1.00" (25.40mm) 0.040" (1.02mm) 0.250" (6.35mm)

Attenuation @ 68F (20C)


Frequency (MHz) 5 30 45 50 55 83 108 150 181 193 Maximum (db/100 ft.) 0.11 0.26 0.33 0.35 0.37 0.46 0.52 0.62 0.68 0.71 0.74 0.76 0.81 0.85 0.90 0.94 0.97 1.01 1.05 1.08 1.12 1.18 1.24 1.36 1.53 1.64 1.78 Maximum (db/100 m) 0.36 0.85 1.08 1.15 1.21 1.51 1.71 2.03 2.23 2.33 2.43 2.49 2.66 2.79 2.95 3.08 3.18 3.31 3.44 3.54 3.67 3.87 4.07 4.46 5.02 5.38 5.84

Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Nominal Diameter Over Corrugated Armor Nominal Shield Thickness Nominal Diameter Over Outer Jacket Nominal Thickness of Outer Jacket Diameter of Steel Messenger

Mechanical Characteristics
Minimum Bending Radius Without Armor With Armor Pulling Tension Minimum Breaking Strength of Messenger 10.0" (25.4cm) 12.5" (31.8cm) 420 lbs. (190 kg) 6,650 lbs. (3016 kg)

211 220 250 270 300 325

Electrical Characteristics
Capacitance Impedance Velocity of Propagation 15.3 1.0 pf/ft. (50 3 nf/km) 75 2 ohms 87%

350 375 400 425 450 500 550 600 750 865 1000

Maximum of DC Resistance @ 68F (20C) Inner Conductor 0.57 ohms/1000 (1.87 ohms/km) Outer Conductor 0.19 ohms/1000 (0.62 ohms/km) Loop 0.76 ohms/1000 (2.49 ohms/km)

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G8

Cable & Connectors Trunk Cable

.875 Parameter III Series Copper Clad Aluminum Sheath COMM /SCOPE

Bare Copper clad aluminum center conductor; expanded polyethylene dielectric; solid aluminum sheath; center conductor 0.194" (4.93mm) nominal; nom. O.D. 0.875" (22.23mm).

Jacketed with Flooding Compound Similar in construction to P3 75-875JCA, except with Migra-Heal compound between jacket and aluminum sheath

Jacketed Similar in construction to P3 75-875CA, except with 0.035" (0.90mm) outer jacket of black medium density polyethylene. Nominal O.D. 0.945" (24.00mm).

Jacketed with Steel Armor Similar to P3 75-875JCASS, except with 0.006" (0.15mm) corrugated chrome plated steel armor applied longitudinally, coated on outside with 0.002" (0.05mm) heat sealable film which bonds to outer jacket and seals edges to form an effective moisture barrier and provide mechanical protection. Nominal O.D. 1.097" (27.86mm). Attenuation @ 68F (20C)
0.194" 0.001" (4.93mm 0.03mm) 0.797" (20.24mm) 0.875 0.010" (22.23mm 0.25mm) 0.039" (0.99mm) 0.945" (24.00mm) 0.035" (0.90mm) 1.017" (27.86mm) 0.008" (0.20mm) 1.127" (28.63mm) 0.040" (1.02mm) 0.250" (6.35mm)
Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 30 45 50 55 83 108 150 181 193 211 0.09 0.24 0.30 0.32 0.33 0.41 0.47 0.55 0.60 0.62 0.66 0.67 0.72 0.75 0.30 0.79 0.98 1.05 1.08 1.35 1.54 1.80 1.97 2.03 2.17 2.20 2.36 2.46 Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 300 325 350 375 400 425 450 500 550 600 750 865 1000 0.79 0.82 0.86 0.89 0.91 0.95 0.98 1.03 1.08 1.20 1.36 1.47 1.59 2.59 2.69 2.82 2.92 2.99 3.12 3.22 3.38 3.54 3.94 4.46 4.82 5.22

Physical Dimensions
Center Conductor Diameter Nominal Diameter Over Dielectric Diameter Over Outer Conductor

Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness

Nominal Diameter Over Corrugated Armor Nominal Shield Thickness Nominal Diameter Over Outer Jacket Nominal Thickness of Outer Jacket Diameter of Steel Messenger

Mechanical Characteristics
Minimum Bending Radius Without Armor With Armor Pulling Tension Minimum Breaking Strength of Messenger 13.5" (34.3cm) 16.0" (40.6cm) 435 lbs. (196 kg) 6,650 lbs. (3016 kg)

220 250 270

Ordering Information Electrical Characteristics


Capacitance Impedance Velocity of Propagation 15.3 1.0 pf/ft. (50 3 nf/km) 75 2 ohms 87% Order No.
CSP 202222 CSP 202223 CSP 202224 CSP 202225

Mfg. No.
P3 75-875CA P3 75-875JCA P3 75-875JCASS P3 75-875JACASS

Description
Bare Jacketed Jacketed with Flooding Compound Jacketed with Steel Armor & Flooding Compound

Maximum of DC Resistance @ 68F (20C) Inner Conductor 0.42 ohms/1000 (1.38 ohms/km) Outer Conductor 0.13 ohms/1000 (0.43 ohms/km) Loop 0.55 ohms/1000 (1.81 ohms/km)
SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G9

1996 TELEWIRE SUPPLY

Cable & Connectors Equipment for Line Vehicles

1.00 Parameter III Series Copper Clad Aluminum Sheath COMM /SCOPE

Bare Copper clad aluminum center conductor; expanded polyethylene dielectric; solid aluminum sheath; center conductor 0.225" (5.69mm) nominal; nom. O.D. 1.000" (25.40mm).

Jacketed with Flooding Compound Similar in construction to P3 75-1000JCA, except with Migra-Heal compound between jacket and aluminum sheath

Jacketed Similar in construction to P3 75-1000CA, except with 0.035" (0.90mm) outer jacket of black medium density polyethylene. Nominal O.D. 1.08" (27.43mm).

Jacketed with Steel Armor Similar to P3 75-1000JCASS, except with 0.006" (0.15mm) corrugated chrome plated steel armor applied longitudinally, coated on outside with 0.002" (0.05mm) heat sealable film which bonds to outer jacket and seals edges to form an effective moisture barrier and provide mechanical protection. Nominal O.D. 1.26" (32.00mm). Attenuation @ 68F (20C)
Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 30 45 50 55 83 108 150 181 193 0.09 0.23 0.28 0.30 0.31 0.39 0.44 0.52 0.59 0.60 0.62 0.63 0.68 0.71 0.30 0.75 0.92 0.98 1.02 1.28 1.44 1.71 1.94 1.97 2.03 2.07 2.23 2.33 Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 300 325 350 375 400 425 450 500 550 600 750 865 1000 0.75 0.78 0.81 0.84 0.87 0.90 0.92 0.98 1.03 1.08 1.23 1.34 1.47 2.46 2.56 2.66 2.76 2.85 2.95 3.02 3.21 3.38 3.54 4.04 4.40 4.82

Physical Dimensions
Center Conductor Diameter Nominal Diameter Over Dielectric Diameter Over Outer Conductor 0.225" 0.002" (5.69mm 0.05mm) 0.890" (22.61mm) 1.000 0.015" (25.40mm 0.3mm) 0.055" (1.40mm) 1.08" (27.43mm) 0.035" (0.90mm) 1.20" (30.48mm) 0.008" (0.20mm) 1.26" (32.00mm) 0.040" (1.02mm) 0.250" (6.35mm)

Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Nominal Diameter Over Corrugated Armor Nominal Shield Thickness Nominal Diameter Over Outer Jacket Nominal Thickness of Outer Jacket Diameter of Steel Messenger

Mechanical Characteristics
Minimum Bending Radius Without Armor With Armor Pulling Tension Minimum Breaking Strength of Messenger 15" (38.1cm) 18" (45.7cm) 490 lbs. (222 kg) 6,650 lbs. (3016 kg)

211 220 250 270

Electrical Characteristics
Capacitance Impedance Velocity of Propagation 15.3 1.0 pf/ft. (50 3 nf/km) 75 2 ohms 87%

Ordering Information
Order No.
CSP 202226 CSP 202227 CSP 202228 CSP 202229

Mfg. No.
P3 75-1000CA P3 75-1000JCA P3 75-1000JCASS P3 75-1000JACASS

Description
Bare Jacketed Jacketed with Flooding Compound Jacketed with Steel Armor & Flooding Compound

Maximum of DC Resistance @ 68F (20C) Inner Conductor 0.32 ohms/1000 (1.05 ohms/km) Outer Conductor 0.08 ohms/1000 (0.26 ohms/km) Loop 0.40 ohms/1000 (1.31 ohms/km)

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G10

Cable & Connectors Trunk Cable - .540 QR Series

.540 Quantum Reach Series Copper Clad Aluminum Sheath COMM/SCOPE


Jacketed with Flooding Compound Similar in construction to QR-540JCA, except with Migra-Heal flooding compound which inhibits cable corrosion in the event of severe jacket damage. Jacketed Copper clad aluminum center conductor; Double-Clad center conductor treatment inhibits water migration and corrosion; dielectric with new micro cellular structure provides lower attenuation, and dielectric adhesive inhibits water migration, connector pull-out and enhances handling characteristics; aluminum outer conductor with continuous R.F. welded construction eliminates signal leakage, with good flexibility for improved handling properties; medium density polyethylene jacket is stronger and tougher than conventional jackets; center conductor 0.124" (3.19mm) nominal; nom. O.D. .610" (15.49mm).

Jacketed with Flooding Compound with Steel Armor Similar to QR-540JCASS, except with .006" (.15mm) corrugated chrome plated steel armor applied longitudinally and with flooding compound between the armor and the inner jacket. Armor is bonded to the outer jacket and enhances cable longevity in burial applications. Nominal O.D. .765" (19.43mm).

Physical Dimensions
Center Conductor Diameter Nominal Diameter Over Dielectric Diameter Over Outer Conductor 0.166" 0.001" (4.22mm 0.03mm) 0.686" (17.42mm) 0.785 0.010" (19.94mm 0.25mm) 0.0145" (0.37mm) 0.785" (19.94mm) 0.035" (0.89mm) 0.855" (22.81mm) 0.0083" (0.20mm) 0.935" (23.75mm) 0.040" (1.02mm)

Attenuation @ 68F (20C)


Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 30 45 50 55 83 108 150 181 0.14 0.35 0.41 0.44 0.47 0.58 0.67 0.79 0.88 0.90 0.95 0.98 1.03 1.08 0.46 1.15 1.35 1.44 1.54 1.90 2.20 2.59 2.89 2.95 3.12 3.22 3.38 3.54 Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 300 325 350 375 400 425 450 500 550 600 750 865 1000 1.14 1.20 1.23 1.30 1.33 1.37 1.41 1.50 1.58 1.66 1.86 2.00 2.17 3.74 3.94 4.03 4.27 4.36 4.49 4.63 4.92 5.18 5.45 6.10 6.56 7.12

Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness

Nominal Diameter Over Corrugated Armor Nominal Shield Thickness Nominal Diameter Over Outer Jacket Nominal Thickness of Outer Jacket

Mechanical Characteristics
Minimum Bending Radius Without Armor Maximum Pulling Tension 5.0" (12.7cm) 340 lbs. (154 kg)

193 211 220 250

Electrical Characteristics
Capacitance Impedance Velocity of Propagation 15.3 1.0 pf/ft. (50 3 nf/km) 75 2 ohms 88%

270

Ordering Information
Order No.
CSP 202230 CSP 202425 CSP 202232

Maximum of DC Resistance @ 68F (20C) Inner Conductor 0.579 ohms/1000 (1.90 ohms/km) Outer Conductor 0.418 ohms/1000 (1.37 ohms/km) Loop 0.997 ohms/1000 (3.27 ohms/km)

Mfg. No.
QR-540JCA QR-540JCASS QR-540JACASS

Description
Jacketed Jacketed with Flooding Compound Jacketed with Flooding Compound and Steel Armor

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G11

1996 TELEWIRE SUPPLY

Cable & Connectors Trunk Cable

.715 Quantum Reach Series Copper Clad Aluminum Sheath COMM/SCOPE


Jacketed with Flooding Compound Similar to QR-715JCA, except with Migra-Heal flooding compound which inhibits cable corrosion in the event of severe jacket damage. Jacketed Copper clad aluminum center conductor; Double-Clad center conductor treatment inhibits water migration and corrosion; dielectric with new micro cellular structure provides lower attenuation, and dielectric adhesive inhibits water migration, connector pull-out and enhances handling characteristics; aluminum outer conductor with continuous R.F. welded construction eliminates signal leakage, with good flexibility for improved handling properties; medium density polyethylene jacket is stronger and tougher than conventional jackets; center conductor 0.166" (4.22mm) nominal; nom. O.D. 0.785" (19.94mm).

Jacketed with Flooding Compound with Steel Armor Similar to QR-715JCASS, except with .006" (.15mm) corrugated chrome plated steel armor applied longitudinally and with flooding compound between the armor and the inner jacket. Armor is bonded to the outer jacket and enhances cable longevity in burial applications. Nominal O.D. 0.935" (23.75mm).

Physical Dimensions
Center Conductor Diameter Nominal Diameter Over Dielectric Diameter Over Outer Conductor 0.124" 0.001" (3.19mm 0.03mm) 0.513" (13.03mm) 0.610 0.010" (15.49mm 0.25mm) 0.0135" (0.343mm) 0.610" (15.49mm) 0.035" (0.89mm) 1.685" (17.39mm) 0.008" (0.20mm) 0.765" (19.43mm) 0.040" (1.02mm)

Attenuation @ 68F (20C)


Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 30 45 50 55 83 108 150 181 0.11 0.27 0.33 0.35 0.36 0.45 0.51 0.61 0.68 0.70 0.74 0.76 0.81 0.84 0.36 0.89 1.08 1.15 1.18 1.48 1.67 2.00 2.23 2.30 2.43 2.49 2.66 2.76 Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 300 325 350 375 400 425 450 500 550 600 750 865 1000 0.89 0.94 0.97 1.01 1.05 1.09 1.12 1.19 1.26 1.32 1.50 1.64 1.78 2.92 3.08 3.18 3.31 3.44 3.58 3.67 3.90 4.13 4.33 4.92 5.38 5.84

Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Nominal Diameter Over Corrugated Armor Nominal Shield Thickness Nominal Diameter Over Outer Jacket Nominal Thickness of Outer Jacket

Mechanical Characteristics
Minimum Bending Radius Without Armor Maximum Pulling Tension 5.0" (12.7cm) 220 lbs. (100 kg)

193 211 220 250

Electrical Characteristics
Capacitance Impedance Velocity of Propagation 15.3 1.0 pf/ft. (50 3 nf/km) 75 2 ohms 88%

270

Ordering Information
Order No.
CSP 144442 CSP 144471 CSP 144472

Maximum of DC Resistance @ 68F (20C) Inner Conductor 1.02 ohms/1000 (3.34 ohms/km) Outer Conductor 0.59 ohms/1000 (1.94 ohms/km) Loop 1.61 ohms/1000 (5.28 ohms/km)

Mfg. No.
QR-715JCA QR-715JCASS QR-715JACASS

Description
Jacketed Jacketed with Flooding Compound Jacketed with Flooding Compound and Steel Armor

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G12

Cable & Connectors Trunk Cable

.860 Quantum Reach Series Copper Clad Aluminum Sheath COMM/SCOPE


Jacketed with Flooding Compound Similar in construction to QR-860JCA, except with Migra-Heal flooding compound which inhibits cable corrosion in the event of severe jacket damage. Jacketed Copper clad aluminum center conductor; Double-Clad center conductor treatment inhibits water migration and corrosion; dielectric with new micro cellular structure provides lower attenuation, and dielectric adhesive inhibits water migration, connector pull-out and enhances handling characteristics; aluminum outer conductor with continuous R.F. welded construction eliminates signal leakage, with good flexibility for improved handling properties; medium density polyethylene jacket is stronger and tougher than conventional jackets; center conductor 0.203" (5.16mm) nominal; nom. O.D. 0.940" (23.88mm).

Jacketed with Flooding Compound with Steel Armor Similar to QR-860JCASS, except with .006" (.15mm) corrugated chrome plated steel armor applied longitudinally and with flooding compound between the armor and the inner jacket. Armor is bonded to the outer jacket and enhances cable longevity in burial applications. Nominal O.D. 1.115" (28.32mm).

Physical Dimensions
Center Conductor Diameter Nominal Diameter Over Dielectric Diameter Over Outer Conductor 0.203" 0.001" (5.16mm 0.03mm) 0.828" (21.03mm) 0.940 0.010" (23.88mm 0.25mm) 0.016" (0.41mm) 0.960" (24.38mm) 0.050" (1.27mm) 1.030" (26.16mm) 0.008" (0.20mm) 1.110" (28.19mm) 0.040" (1.02mm)

Attenuation @ 68F (20C)


Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 30 45 50 55 83 108 150 181 0.09 0.24 0.29 0.31 0.32 0.40 0.46 0.54 0.59 0.60 0.64 0.65 0.70 0.72 0.30 0.79 0.95 1.02 1.05 1.31 1.51 1.77 1.94 1.97 2.10 2.13 2.30 2.36 Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 300 325 350 375 400 425 450 500 550 600 750 865 1000 0.76 0.80 0.83 0.86 0.88 0.92 0.95 1.00 1.06 1.10 1.24 1.33 1.44 2.49 2.62 2.72 2.82 2.89 3.02 3.12 3.28 3.48 3.61 4.07 4.36 4.72

Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness

Nominal Diameter Over Corrugated Armor Nominal Shield Thickness Nominal Diameter Over Outer Jacket Nominal Thickness of Outer Jacket

Mechanical Characteristics
Minimum Bending Radius Without Armor Maximum Pulling Tension 7.0" (17.8cm) 450 lbs. (204 kg)

193 211 220 250

Electrical Characteristics
Capacitance Impedance Velocity of Propagation 15.3 1.0 pf/ft. (50 3 nf/km) 75 2 ohms 88%

270

Ordering Information
Order No.
CSP 202233 CSP 202234 CSP 202235

Maximum of DC Resistance @ 68F (20C) Inner Conductor 0.406 ohms/1000 (1.33 ohms/km) Outer Conductor 0.318 ohms/1000 (1.04 ohms/km) Loop 0.724 ohms/1000 (2.37 ohms/km)

Mfg. No.
QR-860JCA QR-860JCASS QR-860JACASS

Description
Jacketed Jacketed with Flooding Compound Jacketed with Flooding Compound and Steel Armor

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G13

1996 TELEWIRE SUPPLY

Cable & Connectors Trunk Cable

1.125 Quantum Reach Series Copper Clad Aluminum Sheath COMM/SCOPE


Jacketed with Flooding Compound Similar in construction to QR-1125JCA, except with Migra-Heal flooding compound which inhibits cable corrosion in the event of severe jacket damage. Jacketed Copper clad aluminum center conductor; Double-Clad center conductor treatment inhibits water migration and corrosion; dielectric with new micro cellular structure provides lower attenuation, and dielectric adhesive inhibits water migration, connector pull-out and enhances handling characteristics; aluminum outer conductor with continuous R.F. welded construction to eliminate signal leakage, with good flexibility for improved handling properties; medium density polyethylene jacket is stronger and tougher than conventional jackets; center conductor 0.263" (6.68mm) nominal; nom. O.D. 1.225" (31.12mm).

Jacketed with Flooding Compound with Steel Armor Similar to QR-1125JCASS, except with 1.30" (.33.02mm) corrugated chrome plated steel armor applied longitudinally and with flooding compound between the armor and the inner jacket. Armor is bonded to the outer jacket and enhances cable longevity in burial applications. Nominal O.D. 1.380" (35.5mm).

Physical Dimensions
Center Conductor Diameter Nominal Diameter Over Dielectric Diameter Over Outer Conductor 0.263" 0.001" (6.68mm 0.03mm) 1.081" (27.46mm) 1.225 0.010" (31.12mm 0.25mm) 0.021" (0.53mm) 1.225" (31.12mm) 0.050" (1.27mm) 1.300" (33.02mm) 0.010" (0.25mm) 1.380 (35.05mm) 0.040" (1.02mm)

Attenuation @ 68F (20C)


Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 5 30 45 50 55 83 108 150 181 0.07 0.17 0.21 0.22 0.23 0.29 0.34 0.41 0.45 0.47 0.49 0.50 0.54 0.56 0.23 0.56 0.69 0.72 0.76 0.95 1.12 1.35 1.48 1.54 1.61 1.64 1.77 1.84 Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) 300 325 350 375 400 425 450 500 550 600 750 865 1000 0.60 0.61 0.65 0.68 0.70 0.73 0.75 0.80 0.84 0.90 1.07 1.17 1.28 1.97 2.00 2.13 2.23 2.30 2.40 2.46 2.62 2.76 2.95 3.51 3.84 4.20

Nominal Outer Conductor Thickness Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Nominal Diameter Over Corrugated Armor Nominal Shield Thickness Nominal Diameter Over Outer Jacket Nominal Thickness of Outer Jacket

Mechanical Characteristics
Minimum Bending Radius Without Armor Maximum Pulling Tension 10.0" (25.4cm) 500 lbs. (227 kg)

193 211 220 250

Electrical Characteristics
Capacitance Impedance Velocity of Propagation 15.3 1.0 pf/ft. (50 3 nf/km) 75 2 ohms 88%

270

Ordering Information
Order No.
CSP 202236 CSP 202237 CSP 202238

Maximum of DC Resistance @ 68F (20C) Inner Conductor 0.24 ohms/1000 (0.79 ohms/km) Outer Conductor 0.18 ohms/1000 (0.59 ohms/km) Loop 0.42 ohms/1000 (1.38 ohms/km)

Mfg. No.
QR-1125JCA QR-1125JCASS QR-1125JACASS

Description
Jacketed Jacketed with Flooding Compound Jacketed with Flooding Compound and Steel Armor

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G14

Cable & Connectors Fire Safety Requirements

CommScope PIII & QR Cable Weights


Standard Reel Length (feet)
2,400 2,400 2,400 2,400 2,400 2,400 2,400 2,400 2,400 2,400 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,400 2,400 2,400 2,400

Description
P3 75-500 CA P3 75-500JCA P3 75-500 JCASS P3 75-500 JACASS P3 75-500 JCAM-109 P3 75-625 CA P3 75-625 JCA P3 75-625 JCASS P3 75-625 JACASS P3 75-625 JCAM-109 P3 75-750 CA P3 75-750 JCA P3 75-750 JCASS P3 75-750 JACASS P3 75-750 JCAM-250 P3 75-875 CA P3 75-875 JCA P3 75-875 JCASS P3 75-875 JACASS P3 75-1000 CA P3 75-1000 JCA P3 75-1000 JCASS P3 75-1000 JACASS

Cable Weight lbs/1000'


71 95 99 209 133 114 139 143 281 178 162 197 205 360 345 216 257 263 441 311 365 372 581

Reel Size (Inches)


35" x 16" x 18" 35 x 16 x 18 35 x 16 x 46 42 x 24 x 24 42 x 18 x 16.5 42 x 24 x 24 42 x 24 x 24 42 x 24 x 24 50 x 24 x 24 50 x 24 x 24 50 x 24 x 24 50 x 24 x 24 50 x 24 x 24 54 x 24 x 24 54 x 30 x 30 55 x 30 x 24 55 x 30 x 24 55 x 30 x 24 63 x 40 x 26 63 x 40 x 26 63 x 40 x 26 63 x 40 x 26 65 x 42 x 30

Empty Reel Weight


60 lbs 60 lbs 60 lbs 94 lbs 94 lbs 94 lbs 94 lbs 94 lbs 166 lbs 166 lbs 166 lbs 166 lbs 166 lbs 208 lbs 300 lbs 211 lbs 211 lbs 211 lbs 304 lbs 304 lbs 304 lbs 304 lbs 374 lbs

Cable Guard Series


P3 75-500 JCASS-CG P3 75-625 JCASS-CG P3 75-750 JCASS-CG QR 75-540 JCA QR 75-540 JCASS QR 75-540 JACASS QR 75-540 JCAM-109 QR 75-715 JCA QR 75-715 JCASS QR 75-715 JACASS QR 75-715 JCAM-188 QR 75-860 JCA QR 75-860 JCASS QR 75-860 JACASS QR 75-860 JCAM-188 QR 75-1125 JCA QR 75-1125 JCASS QR 75-1125 JACASS 2,400 2,400 2,500 3,700 3,700 3,700 3,700 3,000 3,000 3,000 3,000 2,700 2,700 2,700 2,700 3,000 3,000 3,000 138 199 256 92 92 207 132 145 145 288 233 213 214 393 309 341 341 571 42 x 24 x 24 50 x 24 x 24 54 x 30 x 30 42 x 24 x 24 42 x 24 x 24 50 x 24 x 24 50 x 24 x 24 50 x 24 x 20 50 x 24 x 20 54 x 30 x 24 54 x 24 x 24 54 x 24 x 24 54 x 24 x 24 61 x 30 x 24 61 x 30 x 30 61 x 30 x 30 61 x 30 x 30 72 x 40 x 38 94 lbs 166 lbs 300 lbs 94 lbs 94 lbs 166 lbs 166 lbs 182 lbs 182 lbs 211 lbs 208 lbs 208 lbs 208 lbs 256 lbs 25 lbs 256 lbs 256 lbs 375 lbs

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G15

1996 TELEWIRE SUPPLY

Cable & Connectors Cable Specifications

Quantity of Cable Remaining on a Reel COMM/SCOPE


The amount of cable on a standard size reel may be estimated by counting the layers of cable and multiplying the number of layers by the length per layer. These estimates are presented as the closest full layer of cable.
Cable Size
P3 500 P3 625 P3 750 P3 875 P3 1000

P-3 Products (In Feet) Layers 500


1 2 3 4 5 6 7 8 9 10 11 12 13 150 300 475 650 825

500J 625
125 250 400 550 700 225 500 750 1050 1325 1650

625J 750
200 425 675 925 1175 1450 1750 2050 2350 2400 250 500 775 1050 1350 1675 2000 2325 2500

750J 875
225 450 700 975 1250 1525 1825 2150 2475 2500 250 500 775 1075 1375 1700 2025 2350 2500

875J 1000 1000J


225 450 700 975 1250 1525 1825 2150 2450 2500 175 350 550 750 975 1200 1450 1700 1975 2250 2400 165 340 540 735 960 1180 1430 1675 1950 2225 2400

Standard Length (Ft.)


2,400 2,400 2,500 2,500 2,400

Cable Size
QR 540 QR 715 QR 860 QR 1125

Standard Length (Ft.)


3,700 3,000 2,700 3,000

1025 875

1250 1050 1950 1450 1250 2300 1675 1450 2400 1925 1650 2175 1875 2400 2100 2400

QR Products Layers 540J 715J 860J 1125J


1 2 3 4 5 6 7 8 9 10 11 12 13 14 230 525 775 1075 1350 1675 1975 2325 2650 2950 3300 3700 160 331 512 704 906 1118 1341 1575 1819 2074 2340 2615 2900 3000 225 450 700 975 1250 1525 1825 2150 2450 2700 245 490 735 985 1235 1485 1735 1985 2240 2495 2750 3000

Truckload Quantity of Coaxial Cable Reel Size


35" 35" 35" 35" 42" 42" 42" 42" 50" 50" 54" 42" 55" 63" 42" 42" 50" 54" 61" *Standing Upright

Type
Bare Bare Jacketed Jacketed Armored Armored Messenger Messenger Bare Jacketed Armored Bare & Jacketed Bare & Jacketed Bare & Jacketed

No. Reels
152 152 114 114 48 48 72 48 62 52 30 72 36 20 72, 36* 72, 36* 50, 15* 40, 17* 17, 14*

Reel Truckload Product XLengths =Qty.


500 412 500J 412J 500 412 500 412 750 750J 750 625 875 1000 QR 500 QR 540 QR 715 QR 860 QR1125 2,450 3,000 2,450 3,000 2,450 3,000 2,400 3,000 2,500 2,500 2,500 2,450 2,500 2,500 3,700 3,700 3,000 2,500 3,000 370,000 450,000 275,000 350,000 118,000 144,000 176,000 144,000 150,000 150,000 75,000 175,000 90,000 50,000 266,000, 133,000* 266,000, 133,000* 150,00, 45,000* 100,000, 42,000* 51,000, 42,000*

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G16

Cable & Connectors Cable Specifications

1990 National Electrical Code Requirements for Fire Saftey of CATV Cables
The National Electrical Code (NEC) detailing the community antenna television and radio distribution systems is covered in Article 820, Sections 820-1 through 820-53. These codes are safety guidelines established by the National Fire Protection Association (NFPA). Coaxial cables installed as wiring within buildings shall be listed as being resistant to the spread of fire in accordance with the NEC. The tables must be marked in accordance with Table 820-50. Although NEC covers wire and cable installed in factories, office buildings, hotels, motels, apartment buildings, residences, and all cables which pass through any floor, wall, ceiling, or which travel in ducts, plenums, and other air handling spaces, each individual municipality, city, county, or state can decide whether they wish to adopt the 1990 NEC as law. The requirements established by the NEC may be adopted by the state or local building code agencies where jurisdiction of local electrical, building and fire inspector requirements are established and enforced. Local authorities having jurisdiction enforce their own codes. They have the right to accept or refuse any installation in accordance with their local laws. One of the organizations local inspectors rely on to test wire and cable is Underwriter's Laboratories (U.L.) All applicable building codes should be reviewed and electrical, building and fire inspection organizations consulted prior to the selection, installation and operation of any cable products. Article 820-4 details identification marking of cables for use in any given area. Although subject to local interpretation, the marking (printing) stipulation most likely will be a prerequisite for installations. The 1990 NEC classifications for coaxial drop cables are as follows: 1. CATVP [Article 820-51(a), 820-53(a)] - Designed for use in ducts, plenums, and other spaces used for environmental air. This type of cable is commonly referred to as plenum cable and can be used in place of any of the following three levels. 2. CATVR [Article 820-51(b), 820-53(b)] - Designed for installation in vertical runs and penetrating more than one floor, or cables installed in vertical runs in a shaft. Riser cable can be substituted for the remaining lower level flame tests. CATVP cables can be substituted for CATVR applications to maintain electrical integrity of the cable. CATV [Article 820-51(c), 820-53(c)] - Designed for installation in building locations other than the locations covered in 1 and 2 above. These cables pass the UL1581 flame test, similar to IEEE 383, 70000 BTU tray flame test. Cable Markings & Substitutions Listing Type
CATVP CATVR CATV Riser Cable CATV Cable

Reference
820-51 (b) 820-53 (b) 820-51 (c) 820-53 (c)

Permitted Substitutes
None CATVP CATVP, CATVR

Plenum Cable 820-51 (a) 820-53 (a)

Products are listed into the above marking categories through flame and smoke testing using Underwriters Laboratories (UL) procedures. The listing shown below is in descending order of flame test severity: CATVP .......Plenum ..................UL910, NFPA-262 CATVR ......Riser ......................UL1666 CATV .........General Purpose...UL1581 Information in this catalog has been drawn from authoritative sources in their latest available editions. National Electric Code (NEC) is a registered trademark of the National Fire Protection Association, Inc., Quincy, MA for a triennial Electrical Publication. The term National Electric Code, as used herein, means the triennial publication constituting the National Electrical Code and is used with permission of the National Fire Protection Association, Inc. All due concern has been devoted to accuracy but TeleWire Supply cannot be responsible for errors, omissions, or obsolescence. All data herein are subject to change without notice. TeleWire Supply does not manufacture the items described herein. Users are requested to determine directly from the manufacturers tests or to make their own tests to determine the suitability of these materials for their application and to be guided by the results of such tests. All applicable warranties are provided by the manufacturer. Purchasers are requested to determine directly from the manufacturer the applicable product warranty and limitations. Data and suggestions made in this publication are not to be construed as recommendations to use any products in violation of any government law or regulation relating to any material or its use.

3.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G17

1996 TELEWIRE SUPPLY

Cable & Connectors About Drop Cable

Drop Cable
About Non-Plenum Cable Certain sections of the 1987 update of the National Electric Code make distinctions between cable for general building use and cable for restricted use. For instance, Article 725 for remote control, signaling and power limited circuits states that general building cable may run without conduit in certain concealed spaces (such as walls) while restricted use cable must run in conduit unless it is run a distance of less than 10 feet. For most interbuilding applications, system planners should note that savings can be realized by specifying CL2 cables, as they do not require conduit. Most non-plenum Comm/Scope cables are manufactured with special jacketing and dielectric materials that allow them to meet the CL2 standards. Using CL2X cables when CL2 cables are mandated may pose an unwarranted safety threat. About Multiconductor and Twisted Pair Cables Multiconductor cable is made up of two or more insulated conductors grouped together to make electronic wiring more practical. Applications include communications, instrumentation, sound, control, audio and data transmission. Twisted pair cable consists of wire pairs (two insulated wires twisted around each other) grouped in a cable. The pairs of conductors are twisted to reduce crosstalk and to decrease capacitance unbalance. This usually allows higher data speeds than multiconductor cables. Twisted pair is inexpensive and relatively easy to install. It is gaining rapid acceptance as a transmission medium for a variety of networks, although these systems are presently smaller and slower than networks connected by coaxial cable.

About Plenum Cable Plenums are the enclosed air spaces in office buildings which are used for supply or return ventilation and can house the electrical and communications wiring for the building. Because the air space is unobstructed, plenums represent an area where fire can spread quickly if combustible materials are present. Prior to 1975, the National Fire Protection Agency required that all cables running through a plenum had to be encased in conduit. This regulation was an effort to prevent cable from adding to the heat, flames and smoke in the event of a fire. The development of plenum cable revolutionized the way communication cables are installed. Plenum cable is made of fluoropolymers that propagate flame at a very slow rate and have low smoke generating properties. For these reasons, plenum cables are approved by the National Fire Protection Agency to be installed without conduit. Although plenum cables have a higher initial cost than a similar non-plenum cable, they cost less to install because they do not require conduit. They are especially resistant to cracking, abrasion, chemicals and extreme temperatures (-40F to +400F).

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G18

Cable & Connectors Cable Constructions

Standard Shield Construction


Jacket Aluminum Bonded Dielectric Braided Aluminum Shield Foil Shield Center Conductor

Super Shield (Quad) Construction


Jacket Aluminum Braided Shield Aluminum Foil Shield Aluminum Braided Shield Bonded Aluminum Foil Shield Dielectric Center Conductor

Commscope Drop Cable Part Number Matrix


Foam

F2-5967BVM
Messenger Polyvinylchloride Jacket Bonded % of Braid Coverage Dual 59 Drop Cable Series

Prefix F . . . . . . . . .Foam Polyethylene Dielectric 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Dual 59, 6, 7, 11 . . . . . . . . .Drop Cable Series Sufffix First two digits . . . .% of Braid Coverage (e.g. 53, 60, 67, 90, 95) B . . . . . . . . . . . . . . . . . . . . . .Bonded Foil E . . . . . . . . . . . .Polyethylene Jacket (PE) V . . . . . . .Polyvinylchloride Jacket (PVC) M . . . . . . . . . . . . . . . . . . . . . . .Messenger F . . . . . . . . . . . . . . . . . . . . . . . . . .Flooded SS . . . . . . . . . . . . . . . . . . . .Super Shield TS . . . . . . . . . . . . . . . . . . . . . . .Tri-Shield CRD . . . . . . . . .Corrosion Resistant Drop APD . . .Amorphous Polypropylene Drop V . . . . . . . . . . . . . . . . . . . . . . .NEC CATV R . . . . . . . . . . . . . . . . . . . . . .NEC CATVR FT1 . . . . . . . . . . . . . . . . .CSA Flame Test FT4 . . . . . . . . . . . . . . . . .CSA Flame Test
SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288

F5967BVM
Flooded Polyethylene Jacket Foam 59 Drop Cable Series Bonded % of Braid Coverage

F59SSVR
Riser Foam 59 Drop Cable Series Polyvinylchloride Jacket Super-Shield

F2-5967BV-CRD
Corrosion Resistant Drop Cable Foam Dual 59 Drop Cable Series Polyvinylchloride Jacket Bonded % of Braid Coverage

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G19

1996 TELEWIRE SUPPLY

Cable & Connectors Drop Cable

Drop Cable RG 59

Basic Construction 20 AWG (nom. 0.032" [0.81mm]) copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D. 0.242" (6.15mm). 20 dB minimum SLR at 5-1000 MHz. All cables listed meet NEC article 820 and have at least a "V" rating.

Ordering Information Description


RG 59 67% Braid Black in a box RG 59 67% Braid White in a box RG 59 67% Braid Neutral in a box

Order No.
CSP 202349 CSP 202350 CSP 202351

CommScope
F5967BVV-BOX-BLACK F5967BVV-BOX-WHITE F5967BVV-BOX-NEUTRAL

Order No.
BEL 202361 BEL 202362 BEL 202363

Belden
9104U-BLACK 9104U-WHITE 9104U-NEUTRAL

RG 59 67% Braid Black on a reel Messengered RG 59 67% Braid on a reel Underground RG 59 67% Braid on a reel

CSP 202352 CSP 202353 CSP 202354

F5967BVV-REEL-BLACK F5967BVM-REEL-BLACK F5967BEF-REEL-BLACK

BEL 202364 BEL 202365 BEL 202366

9104-REEL-BLACK 9105-REEL-BLACK 9067-REEL-BLACK

RG 59 Quad-Shield Black in a box RG 59 Quad-Shield White in a box RG 59 Quad-Shield Neutral in a box

CSP 202355 CSP 202356 CSP 202357

F59SSVV-BOX-BLACK F59SSVV-BOX-WHITE F59SSVV-BOX-NEUTRAL

N/A N/A N/A

G
1186A-REEL-BLACK 1188A-REEL-BLACK 1187A-REEL-BLACK

RG 59 Quad-Shield Black on a reel

CSP 202358

F59SSVV-REEL-BLACK F59SSVM-REEL-BLACK F59SSEF-REEL-BLACK

BEL 202367 BEL 202368 BEL 202369

Messengered RG 59 Quad-Shield on a reel CSP 202359 Underground RG 59 Quad-Shield on a reel CSP 202360 All come in 1000 ft. lengths +-10%

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G20

Cable & Connectors Drop Cable

Drop Cable RG 6

Basic Construction 18 AWG (nom. 0.040" [1.02mm]) copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D. 0.272" (6.91mm). 20 dB minimum SLR at 5-1000 MHz. All cables listed meet NEC article 820 and have at least a "V" rating.

Ordering Information Description


RG6 60% Braid Black in a box RG6 60% Braid White in a box RG6 60% Braid Neutral in a box

Order No.
CSP 202370 CSP 202371 CSP 202372

CommScope
F660BVV-BOX-BLACK F660BVV-BOX-WHITE F660BVV-BOX-NEUTRAL

Order No.
BEL 202382 BEL 202383 BEL 202384

Belden
9116U-BLACK 9116U-WHITE 9116U-NEUTRAL

RG6 60% Braid Black on a reel Messengered RG6 60% Braid on a reel Underground RG6 60% Braid on reel

CSP 202373 CSP 202374 CSP 202375

F660BVV-REEL-BLACK F660BVM-REEL-BLACK F660BEF-REEL-BLACK-PE

BEL 202385 BEL 202386 BEL 202387

9116-REEL-BLACK 9117-REEL-BLACK 9066-REEL-BLACK-PE

RG6 Quad-Shield Black in a box RG6 Quad-Shield White in a box RG6 Quad-Shield Neutral in a box

CSP 202376 CSP 202377 CSP 202378

F6SSVV-BOX-BLACK F66SSVV-BOX-WHITE F66SSVV-BOX-NEUTRAL

BEL 202388 BEL 202389 BEL 202390

1189U-BLACK 1189U-WHITE 1189U-NEUTRAL

G
RG6 Quad-Shield Black on a reel Messengered RG6 Quad-Shield Black on a reel Underground RG6 Quad-Shield Black on a reel All come in 1000 ft. lengths +-10% CSP 202379 CSP 202380 CSP 202381 F6SSVB-REEL-BLACK F6SSVM-REEL-BLACK F6SSEF-REEL-BLACK BEL 202391 BEL 202392 BEL 202393 1189A-REEL-BLACK 1191A-REEL-BLACK 1190A-REEL-BLACK

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G21

1996 TELEWIRE SUPPLY

Cable & Connectors Equipment for Line Vehicles

Drop Cable RG 7

Basic Construction 16 AWG (nom. 0.0508" [1.29mm]) copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D. 0.340" (8.64mm). 20 dB minimum SLR at 5-1000 MHz. All cables listed meet NEC article 820 and have at least a "V" rating.

Ordering Information RG -7 Description


RG7 60% Braid Black on a reel Messengered RG7 60% Braid Black on a reel Underground RG7 60% Braid Black on a reel

Order No.
CSP 202394 CSP 202395 CSP 202396

CommScope
F760BVV-REEL-BLACK F760BVM-REEL-BLACK F760BEF-REEL-BLACK

Order No.
BEL 202400 BEL 202401 BEL 202402

Belden
1844A 1845A 1846A

RG7 Quad-Shield Black on a reel Messengered RG7 Quad-Shield Black on a reel Underground RG7 Quad-Shield Black on a reel

CSP 202397 CSP 202398 CSP 202399

F7SSVV-REEL-BLACK F7SSVM-REEL-BLACK F7SSEF-REEL-BLACK

BEL 202403 BEL 202404 BEL 202405

1833A 1834A 1835A

All come in 1000 ft. lengths + - 10%

Drop Cable RG-11

Ordering Information RG -11 Description


RG11 60% Braid Black on a reel Messengered RG11 60% Braid Black on a reel Underground RG11 60% Braid Black on a reel

Basic Construction 14 AWG (nom. 0.064" [1.63mm]) copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D. 0.405" (10.29mm). 20 dB minimum SLR at 5-1000 MHz. All cables listed meet NEC article 820 and have at least a "V" rating. Order No.
CSP 202406 CSP 202407 CSP 202408

CommScope
F1160BVV-REEL-BLACK F1160BVM-REEL-BLACK F1160BEF-REEL-BLACK

Order No.
BEL 202412 BEL 202413 BEL 202414

Belden
1523A 1523A 1525A

RG11 Quad-Shield Black on a reel Messengered RG11 Quad-Shield Black on a reel Underground RG11 Quad-Shield Black on a reel

CSP 202409 CSP 202410 CSP 202411

F11SSVV-REEL-BLACK F11SSVM-REEL-BLACK F11SSEF-REEL-BLACK

BEL 202415 BEL 202416 BEL 202417

1617A 1619A 1618A

All come in 1000 ft. lengths + - 10%

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G22

Cable & Connectors Cables

Wireless / DBS Cables 1800 MHz

Basic Construction Direct Broadcast Satellite (DBS) is a method for bringing video services to satellite subscribers. Whereas conventional broadband coax may be tested to only 1 GHz, coaxial DBS cables are sweep tested to 1.8 GHz. They are guaranteed to have minimum SRL performance levels of 18 dB to 1.45 GHz and 15 dB beyond that, out to 1.8 GHz.

Ordering Information Description


RG6 60% Braid Black RG6 60% Braid Dual Black RG6 60% Braid Dual with Ground Wire Black RG6 60% Braid Dual with Flooding Compound Black RG6 60% Braid Dual with Flooding Compound

CommScope # TeleWire #
5730 5786 5788 5787 CNT 081705 CNT 133672 CNT 296500 CNT 604993

Belden #
1829A 1841A 1840A 1842A 1843A

TeleWire#
BEL 202447 BEL 202448 BEL 202449 BEL 202450 BEL 202451

5789 CNT 201505 and Ground Wire Black

All come in 1000 ft. lengths + - 10%

Plenum Cables
Basic Construction Plenums are the enclosed air spaces in office buildings which are used for supply or return ventilation and can house the electrical and communications wiring for the building. Because the air space is unobstructed, plenums represent an area where fire can be spread quickly if combustible materials are present. Ordering Information Order No.
CNT 200240 CNT 202459 CNT 202458 CNT 296476

Mfg. No.
2020K 2275K 2227K 2285K

Plenum Cable is made of fluoropolymers that propagate flame at a very slow rate and have low smoke generating properties. For these reasons, plenum cables are approved by the National Fire Protection Agency to be installed without conduit. Description
RG59 67% Braid RG6 60% Braid RG6 Quad shield RG11 60% Braid

Although plenum cables have a higher initial cost than a similar non-plenum cable, they cost less to install because they do not require conduit. They are especially resistant to cracking, abrasion, chemicals and extreme temperatures. (-40F to +400F).

All come in 1000 ft. lengths + - 10%

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G23

1996 TELEWIRE SUPPLY

Cable & Connectors Headend Cable

Headend Cable
BELDEN
RG59 (9167) Basic Construction 20 AWG (nom. 0.032" [0.81mm]) silver plated copper covered steel center conductor; gas injected foam polyethylene dielectric; shield Duobond II plus 95% aluminum braid plus aluminum foil with shorting fold; jacket black polyvinylchloride. Nom. O.D. 0.242" (6.15mm). 29.35 lbs. per 1,000 feet. Ordering Information Order No.
BEL 202452 BEL 294040

Mfg. No.
9167 9168

Description
RG 59 RG 6

RG6 (9168) Basic Construction 18 AWG (nom. 0.040" [1.02mm]) silver plated copper covered steel center conductor; gas injected foam polyethylene dielectric; shield Duobond II plus 95% aluminum braid plus aluminum foil with shorting fold; jacket black polyvinylchloride. Nom. O.D. 0.275" (6.99mm). 31 lbs. per 1,000 feet.

Headend Cable COMM/SCOPE

RG59 (S59 HEC) Basic Construction: 22 AWG (nom. 0.0226" (0.58 mm)) silver plated copper covered steel center conductor; solid natural polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated bonded overlap; outer shields of 34 AWG tinned copper braid; jacket flame retardant black polyvinylchloride. Nom. O.D. 0.265" (6.73 mm). 61 lbs. per 1,000 feet. RG59 (F59 HEC-2) Basic Construction: 22 AWG (nom. 0.0226" (0.58 mm)) silver plated copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated bonded overlap; outer shields of 34 AWG tinned copper braid; jacket flame retardant black polyvinylchloride. Nom. O.D. 0.265" (6.73 mm). 61 lbs. per 1,000 feet. RG 214 RG59 (F59 HEC / 3-22) Basic Construction: 22 AWG (nom. 0.032" [0.81 mm]) silver plated copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; 34 AWG aluminum braid; aluminum-polypropylene-aluminum non-bonded tape; 34 AWG aluminum braid; jacket flame retardant black polyvinylchloride meeting NEC Article 820, CATV category and 725 Class 2 Circuit Ratings. Nom. O.D. 0.270" (6.86 mm). Audio: three pair 22 AWG bare copper, polyethylene insulation; 24 AWG tin/copper drain and polyester rip cord with aluminum shld on each pair; dual construction. 59 lbs. per 1,000 feet. RG214 (7714) Basic Construction: Center conductor: 13 AWG, 7/.0296 SC wire type, 1.73 nom. DCR Ohms/1000'; dielectric: PE, .285" nom. O.D., shield construction: 2-95% SC, .7 nom. DCR/1000'; jacket: NCPVC, .425" nom. O.D.; nom. cap.: 30.8 pt/ft.; velocity of propagation: 66%; impedance: 50 Ohms. 500' reels 159 lbs per 1,000 feet.

Ordering Information Order No.


CSP 202453 CSP 135672 CSP 140798 CNT 201454

Mfg. No.
S59 HEC F59 HEC-2 F59 HEC/3-22 7714

Description
RG 59 RG 59 RG 59 single w/ three 22 AWG twisted pair RG 214

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G24

Audio / Telephone Cable & Headend Connectors

Cable & Connectors

Shielded Twisted Pair Cable


BELDEN
Ordering Information Order No.
BEL 600232 BEL 202460 BEL 600231 BEL 202461

Mfg. No.
8760-U-500 8762-U-500 8451-U-500-8 8451-1000

Description
18 gauge stranded pair chrome jacket 20 gauge stranded pair chrome jacket 22 gauge stranded pair grey jacket 22 gauge stranded pair black jacket

Qty.
500' box 500' box 500' box 1000' reel

Basic Construction: Tinned copper, polyethylene insulated, twisted pair. Beldfoil aluminum-polyester shield, stranded tinned copper drain wire. Chrome PVC jacket. Color code: black, clear.

Telephone Station Wire


JUST DROP
Description Round 4 conductor in 1,000 foot lengths. Ordering Information Order No.
SWI 200904 SWI 200907 SWI 200908 SWI 200906

Mfg. No.
24-4/C beige 24-4/C gray 22-4/C beige 22-4/C gray

Conductor Size Cont.


24 24 22 22 box box box box

Type
beige gray beige gray

RG-213, RG-214 Connectors

RG-213 Male 50 Ohm N type Connector Ordering Information Order No.


PIC 101498 GIL 072913 BHG 137498 BHG 043364

RG-214 Male 50 Ohm N type Connector

Crimp Tool for RG 213 & RG214 N Type Connectors

Mfg. No.
NMA234 GN-214AHS/480 HCT-480 HCT-211

Description
RG-213 RG-214 for RG 213 connectors for RG 214 connectors

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G25

1996 TELEWIRE SUPPLY

Cable & Connectors Connectors

Aluminum Connector Types


Feed-Thru (VSF) A device that seizes only the outer conductor of the coaxial cable. The cable center conductor extends through the connector and is retained within the equipment housing.

Pin Type (Stinger) A connector that seizes both the outer and center conductor. This device has an additional feature not found in the feed-thru type consisting of a solid brass pin which seizes and retains the cable center conductor. The pin then extends through the body and is retained within the equipment housing.

Splice This connector is used to join together two cables. The features of seizing both the outer and center conductors (as in the pintype) are found in this device.

F Female This connector is used when an F female port is required at the end of the cable. It has identical features as the pin-type and splice in that it seizes both the center and outer conductor of the coaxial cable.

F Male This connector is used when it is necessary to have an F male connection at the end of the cable. It has the same features as the pin-type, splice and F female in that both center and outer conductors of the cable are seized.

Extension This connector is used when sufficient cable is not available for installation. It has a pin which seizes and retains the cable center conductor. The pin then extends through the body and is retained with the equipment housing.

Cable Terminator This connector is used in a cable system where it becomes necessary to terminate both RF signal and 60 Hz AC power. It contains the center and outer conductor seizing features as in the pin-type, splice, "F" female and "F" male connectors.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G26

Cable & Connectors Gilbert Connector Quick Reference

Gilbert Aluminum Connectors with Integral Sleeves


Feed Thru ('VSF) Order No.
GIL 023516 GIL 049527 GIL 031927 GIL 023517 GIL 099939 GIL 072632

Mfg. No.
GRS412BA01 GRS412BDU01 GRS412BSDU01 GRS500BA01 GRS500BDU01 GRS500BDU02

Order No. No.


GIL 049528 GIL 095021 GIL 037614 GIL 112733 GIL 049529 GIL 099966

Mfg.
GRS500BDU03 GRS500BMC2 GRS500BSDU03 GRS540BSQR GRS750BDU01 GRS625BDU02

Pin Type ('Stinger')

Order No.
GIL 023518 GIL 061694 GIL 044455 GIL 044459 GIL 022628 GIL 043528 GIL 112650 GIL 023519 GIL 061695 GIL 052449 GIL 087210 GIL 023660

Mfg. No.
GRS412CHA01 GRS412CHA01T GRS412CHA07 GRS412CHA07T GRS412CHDU01 GRS412CHDU01T GRS440CHMC GRS500CHA01 GRS500CHA01T GRS500CHA05 GRS500CHCX GRS500CHDU01 GRS500CHDU01T GRS500CHDU02 GRS500CHDU03 GRS500CHDU03T GRS500CHMC2

Order No.
GIL 094029 GIL 085313 GIL 059442 GIL 112574 GIL 041944 GIL 050245 GIL 109233 GIL 072155 GIL 144117 GIL 144441 GIL 023661 GIL 057112 GIL 146507 GIL 031659 GIL 048086 GIL 042499 GIL 112356

Mfg. No.
GRS500CHMC2T GRS500CHQR GRS540CHQR GRS540CHQRT GRS625CHDU02 GRS625CHDU02T GRS650CHMC2 GRS650CHMC2T GRS715CHQR GRS715CHQRT GRS750CHA01 GRS750CHA01T GRS750CHA02 GRS750CHDU01 GRS750CHDO01T GRS750CHDU03 GRS750CHDO03T

Order No.
GIL 039952 GIL 039953 GIL 073499 GIL 072161 GIL 059452 GIL 112352 GIL 042758 GIL 042759 GIL 050246 GIL 150191 GIL 037931 GIL 056289 GIL 094302 GIL 112785 GIL 114411 GIL 072152

Mfg. No.
GRS750CHFD04 GRS750CHFD04T GRS750CHMC2 GRS750CHMC2T GRS860CHQR GRS860CHQRT GRS875CHA02 GRS875CHDU02 GRS875CHDU02T GRS1000CHA01 GRS1000CHDU01 GRS1000CHDU01T GRS1000CHMC2T GRS1125CHQRT GRS13.0CHDU01 GRS16.5CHDU01T

GIL 096071 GIL 031876 GIL 036247 GIL 042515 GIL 089589

Extension

Order No.
GIL 057115 GIL 042210 GIL 057116 GIL 099964 GIL 101350 GIL 048662

Mfg. No.
GRS412EXTA01T GRS412EXTDU01T GRS500EXTA01T GRS500EXTDU01 GRS500EXTDU03T GRS500EXT9A01

Order No.
GIL 101444 GIL 057117 GIL 101114 GIL 099968 GIL 112782 GIL 146475

Mfg. No.
GRS625EXTDU02T GRS750EXTA01T GRS750EXTDU01T GRS750EXTDU03 GRS860EXTQRT GRS875EXTDU02T

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G27

1996 TELEWIRE SUPPLY

Cable & Connectors Gilbert Connector Quick Reference

Gilbert Aluminum Connectors with Integral Sleeves continued


Splice
Order No.
GIL 023520 GIL 023525 GIL 023524 GIL 044456 GIL 023663 GIL 023521 GIL 037942 GIL 031877 GIL 023664 GIL 036248 GIL 096024 GIL 077852 GIL 059445 GIL 050243

Mfg. No.
GRS412SPA01 GRS412SPA01DU03 GRS412SPA01DU01 GRS412SPA07 GRS412SPDU01 GRS500SPA01 GRS500SPA01DU03 GRS500SPDU01 GRS500SPDU02 GRS500SPDU03 GRS500SPMC2 GRS500SPQR GRS540SPQR GRS625SPDU02

Order No.
GIL 072160 GIL 144840 GIL 023665 GIL 031898 GIL 037729 GIL 076394 GIL 033730 GIL 072158 GIL 059453 GIL 050242 GIL 150188 GIL 037932 GIL 099932 GIL 091962

Mfg. No.
GRS650SPMC2 GRS715SPQR GRS750SPA01 GRS750SPA01DU01 GRS750SPDU01 GRS750SPDU03 GRS750SPFD04 GRS750SPMC2 GRS860SPQR GRS875SPDU02 GRS1000SPA01 GRS1000SPDU01 GRS1000SPMC2 GRS1125SPQR

Cable Terminator

Order No.
GIL 040374 GIL 043481 GIL 077191

Mfg. No.
GRS500TRA01 GRS500TRDU03 GRS625TRDU02

G
"F" Male Order No.
GIL 037933 GIL 037934 GIL 037935 GIL 037937

Mfg. No.
GRS412AFMA01 GRS412AFMDU01 GRS500AFMA01 GRS500AFMDU03

"F" Female

Order No.
GIL 024024 GIL 031928 GIL 024023 GIL 035372 GIL 036249 GIL 109191 GIL 112688

Mfg. No.
GRS412BAFFA01 GRS412BAFFDU01 GRS500BAFFA01 GRS500BAFFDU01 GRS500BAFFDU03 GRS500BAFFMC2 GRS540BAFFQR

Order No.
GIL 004657 GIL 031895 GIL 035011 GIL 109242 GIL 059449 GIL 099996 GIL 094299

Mfg. No.
GRS625BAFFDU02 GRS750BAFFA01 GRS750BAFFDU01 GRS750BAFFMC2 GRS860BAFFQR GRS875BAFFDU02 GRS1000BAFFDU01

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G28

Cable & Connectors LRC Connectors Quick Reference

Product Specifications
LRC
Features Structural return loss meets or exceeds 30 dB up to 1 GHz on entry and splice connectors and most adapters Radiation sleeves provide excellent RF integrity and shield effectiveness No-twist center conductor seizing mechanism eliminates radial stress Positive stop feature eliminates guesswork and assures proper tightening of the connector to cable interface O-ring sealed for maximum environmental protection Center conductor cutting guide assures accurate center conductor length One wrench size required for each connector Connector pull force meets or exceeds yield strength of the cable Manufactured from 6262 aluminum alloy and iridite coated for superior corrosion resistance. Threads are lubricated to prevent galling during installation Terminals made from brass are silver plated for excellent RF conductivity Two-inch pin length is standard to accommodate installation requirements Selected plastic materials are used to provide dependable electrical and mechanical integrity at temperatures from -40F to +170F Part number is permanently stamped on connector for easy identification Description The K series is a patented 2-piece design which requires the tightening of only one nut to seize both the center conductor and aluminum sheath of the cable. This design requires less time to install than a 3-piece connector, making installation easier and faster. The W series is the original 3-piece connector design which has been manufactured for over 20 years. The three-piece connector design seizes the center conductor and aluminum sheath of the cable, independent of each other. This is done by tightening two nuts, allowing for full view of the center conductor entrance into the seizing mechanism. The 30 dB minimum return loss has been extended to 1 GHz on pin and splice connectors to accommodate future channel expansion.

Aluminum Connectors with Integral Sleeves


Feed Through ("VSF") Order No.
LRC 096280 LRC 096273

Mfg. No.
EMI412K3 EMI500K EMI500K3 EMI500MC2

Order No.
LRC 071707 LRC 112894 LRC 081916 LRC 112348

Mfg. No.
EMI500P3 EMI540QR EMI625K3 EMI750W3

LRC 081907 LRC 109215

Pin Type (Stinger) Order No.


LRC 096278 LRC 096264 LRC 041312 LRC 040698 LRC 096214 LRC 081906 LRC 109214 LRC 112510 LRC 149154 LRC 055476

Mfg. No.
EI412K EI412K3 EFI500W3 EI500B EI500K EI500K3 EI500MC2 EI540QR EI565TX EI625B3

Order No.
LRC 081914 LRC 109227 LRC 041313 LRC 152637 LRC 081919 LRC 109269 LRC 067372 LRC 049837 LRC 102131 LRC 152635

Mfg. No.
EI625K3 EI650MC2 EFI750W3 EI715K3 EI750K3 EI750MC2 EI860QR EI875B3 EI875K3 EI1000MC2

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G29

1996 TELEWIRE SUPPLY

Cable & Connectors LRC Connector Quick Reference

Aluminum Connectors with Integral Sleeves continued


Extension Order No.
LRC 112339 LRC 040688 LRC 096265 LRC 040710 LRC 096215

Mfg. No.
EFI412PWLB EI412B3LB EI412K3LB EI500BLB EI500KLB

Order No.
LRC 081909 LRC 109197 LRC 149155 LRC 081922

Mfg. No.
EI500K3LB EI500QRLB EI565TXLB EI750K3LB

Splice Order No.


LRC 041314 LRC 096271 LRC 096266 LRC 040700 LRC 096213 LRC 081908 LRC 109213 LRC 112509 LRC 096267

Mfg. No.
SFI750W3 SI412K SI412K3 SI500B SI500K SI500K3 SI500MC2 SI540QR SI625K3

Order No.
LRC 152636 LRC 040726 LRC 040727 LRC 081920 LRC 109268 LRC 112353 LRC 051716 LRC 096269

Mfg. No.
SI715K3 SI750B SI750B3 SI750K3 SI750MC2 SI860QR SI875B3 SI875K3

"F" Female Order No.


LRC 112829 LRC 112495 LRC 081910 LRC 112475 LRC 081923

G
Mfg. No.
AI412FFK3 AI500FFK AI500FFK3 AI500FFW3 AI750FFK3

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G30

Cable & Connectors Connectors

Coaxial Connectors CABLE-CON


Description These products have been designed for coaxial cables with a characteristic impedance of 75 ohms. Connectors are available for most types of commonly used cables. All connectors are designed and constructed of the finest materials to exacting specifications to insure a mechanically and electrically superior interface. Bodies and nuts are made from 6262-T6 aluminum treated with a chromic acid conversion coat to prevent corrosion. All pins are made of brass and plated with bright acid tin. Radiation sleeves are either stainless steel or tin plated brass. Connectors are sealed with o-rings made of ethylene propylene to prevent moisture ingress. Ethylene propylene insures long o-ring life even in high ozone atmospheres. Cabel cons connectors meet stringent quality standards and are tested over a wide range of environmental conditions.

CATV Connectors with True Cable Non-Rotation Feature*


AMPHENOL
Hardline Gold Series Features Installation Friendly Designed with field installation in mind. Easy assembly helps to eliminate installation errors. One wrench size per connector Trim guides in connector body to insure exact center conductor length. Metal to metal positive stop eliminates over tightening of connector. Slim body design allows for easier installation in confined spaces such as pedestals. Smaller wrenches required for easier and lighter handling. Better heat shrink application over connectors and connection into ports. Uses standard coring and stripping tools. No need for special tools. Quality Materials High quality corrosion resistant aluminum alloy parts (6262 or equivalent). High quality 360 brass parts. E/P - Ethylene/Propylene o-rings for superior sealing. O-zone, ultraviolet and salt spray resistant. Tested and guaranteed in all environments. Lubricant on all threads for smooth anti-locking operation. Pressed plastic insulator seals unit from condensation and moisture migration. Top Performance Meets or exceeds industry standards for RFI leakage and return loss. All connectors are swept from .3 MHz to 1 GHz. Environmental testing includes pressure and salt spray tests. Cost Effectiveness Slim design means less material which keeps product costs low. Slim design means a smaller heat shrink which saves dollars on associated material construction costs. 2" Pin standard at no extra charge. *Patent applied for

Three Piece Design Allows for independent confirmation of a secure installation from the seizing of the cables center conductor to the gripping of the cable itself. Visible confirmation of the center conductor entry into the connector body. True Non-rotational design built into body to keep cable from turning. Hardline Connectors Amphenol Gold Series Hardline connectors are the best performing connectors available today with 40 dB return loss up to 1 GHz. The connectors are designed to meet all SCTE, Bellcore and other key industry performance and environmental specifications. They incorporate a true non-rotational three piece design to prevent the cable from turning during installation. Other installation friendly features include slim body design for confined spaces, requirement of one wrench size per connector, and metal to metal positive stop to eliminate over and under tightening of the connector.

Commitment to Quality Products are manufactured at the Amphenol RF/Microwave Operations, Danbury, CT facility which is ISO 9001 System Certified. Amphenol CATV Connectors is dedicated to provide a complete line of quality products including hardline and drop connectors, adaptors, terminators and cable preparation tools. Amphenol CATV Connector products are designed and manufactured to meet our established requirements and the expectations of our customers. We believe that our connector products will enhance the quality of your system, while reducing installation time and providing years of maintenance free service.

Quality S ISO 90ystem Certifie01 d

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G31

1996 TELEWIRE SUPPLY

Cable & Connectors Connectors

Aluminum Connectors for .412 Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

E. "F" Male

F. Extension

G. Cable Terminator

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Cerro Cerrofoam GXX 4412-CC Comm/Scope Parameter III P3-75-412-CA CCS Cable GID-3 46200 Times Lumifoam III JT-4412 Order Fig. No.
A A B B* C D E F G GIL 049527 GIL 031927 GIL 022628 GIL 043528 GIL 023663 GIL 031928 GIL 037934 GIL 042210 GIL 044458

Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

Gilbert No.
GRS412BDU01 GRS412BSDU01 GRS412CHDU01 GRS412CHDU01T GRS412SPDU01 GRS412BAFFDU01 GRS412AFMDU01 GRS412EXTDU01T GRS412TRDU01

Order No.
LRC 096280 LRC 096264 LRC 096266 LRC 112829 LRC 096265

LRC No.
EMI412K3 EI412K3 SI412K3 AI412FFK3 EI412K3LB

Order No.
CBC 604550 CBC 604565

Cabel Con No.


PI-412-CH-3 PI-412-SP-3

The Order Numbers Below Fit the Following Cables General Fused Disc III Cables Order No.
GIL 049527 GIL 031927 GIL 022628 GIL 043528 GIL 023663 GIL 031928 GIL 037934 GIL 042210 GIL 044458

Fig.
A A B B* C D E F G

Gilbert No.
GRS412BDU01 GRS412BSDU01 GRS412CHDU01 GRS412CHDU01T GRS412SPDU01 GRS412BAFFDU01 GRS412AFMDU01 GRS412EXTDU01T GRS412TRDU01
All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin

* Longer Pin Version Contains seal

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G32

Cable & Connectors Connectors

Aluminum Connectors for .412 Cable continued


The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Parameter II P-2-75-412-CA Order Fig. No.
A A B B* C D E F G

Gilbert No.

Order No.

LRC No.

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Cerro Cerrofoam 2412-CC Comm/Scope Cell-O-Air XD-75-412-CA Times Dynaplus JT-2412 Order Fig. No.
A A B B* C D E F G

GIL 049527 GRS412BDU01 GIL 031927 GRS412BSDU01 GIL 022628 GRS412CHDU01 GIL 043528 GRS412CHDU01T GIL 023663 GRS412SPDU01

LRC 096280 EMI412K3

Gilbert No.

Order No.

LRC No.

GIL 049527 GRS412BDU01 GIL 031927 GRS412BSDU01 GIL 022628 GRS412CHDU01 GIL 043528 GRS412CHDU01T GIL 023663 GRS412SPDU01

LRC 096280 EMI412K3

LRC 096264 EI412K3 LRC 096266 SI412K3

GIL 031928 GRS412BAFFDU01 LRC 112829 AI412FFK3 GIL 037934 GRS412AFMDU01

LRC 096264 EI412K3 LRC 096266 SI412K3

GIL 042210 GRS412EXTDU01T LRC 096265 EI412K3LB GIL 044458 GRS412TRDU01

GIL 031928 GRS412BAFFDU01 LRC 112829 AI412FFK3 GIL 037934 GRS412AFMDU01

GIL 042210 GRS412EXTDU01T LRC 096265 EI412K3LB GIL 044458 GRS412TRDU01

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. General Fused Disc .412 Order Fig. No.
A

Gilbert No.

GIL 049527 GRS412BDU01 GIL 031927 GRS412BSDU01 GIL 022628 GRS412CHDU01 GIL 043528 GRS412CHDU01T GIL 023663 GRS412SPDU01 GIL 031928 GRS412BAFFDU01 GIL 037934 GRS412AFMDU01 GIL 042210 GRS412EXTDU01T GIL 044458 GRS412TRDU01

A B B* C D E F G

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. CCS Cable GID 1 44200 CCS Cable Chemafoam 42200 Cerro Cerrofoam GX 3412-CC Comm/Scope Alumagard AL-75-412-CA Comm/Scope Parameter I P1-75-412-CA Times Alumifoam JT-1412 Times Alumifoam II 22-3412 Scientific-Atlanta 20 22-412 Order Fig. No.
A A B B* C D E F

Gilbert No.

Order No.

LRC No.

GIL 023516 GRS412BA01 GIL 112893 GRS412BSA01 GIL 023518 GRS412CHA01 GIL 061694 GRS412CHA01T GIL 023520 GRS412SPA01 GIL 024024 GRS412BAFFA01 GIL 037933 GRS412AFMA01 GIL 057115 GRS412EXTA01T

LRC 096278 EI412K LRC 096271 SI412K

* Longer Pin Version Contains seal

All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G33

1996 TELEWIRE SUPPLY

Cable & Connectors Connectors

Aluminum Connectors for .500 Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

E. "F" Male

F. Extension

G. Cable Terminator
Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Cerro Cerrofoam GXX 4500-CC Comm/Scope Parameter III CCS Cable GID-3 Order Fig. No.
A A B B* C D E F G GIL 049528 GIL 037614 GIL 036247 GIL 042515 GIL 036248 GIL 036249 GIL 037937 GIL 048661 GIL 043481

P3-75-500-CA 56200

Gilbert No.
GRS500BDU03 GRS500BSDU03 GRS500CHDU03 GRS500CHDU03T GRS500SPDU03 GRS500BAFFDU03 GRS500AFMDU03 GRS500EXTDU03T GRS500TRDU03

Order No.
LRC 081907 LRC 081906 LRC 081908 LRC 081910 LRC 109195 LRC 081909

LRC No.
EMI500K3 EI500K3 SI500K3 AI500FFK3 AI500FMK3 EI500K3LB

Order No.

Amphenol No.

Order No.

Cabel Con No.


APL 201513 ACC500CHP3 APL 201525 ACC500SPP3 APL 201537 ACC500BAFFP3

CBC 200361 PI-500-CH-3 CBC 200366 PI-500-SP-3

G
The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. General Fused Disc MIII 6977797 Order No.
GIL 049528 GIL 037614 GIL 036247 GIL 042515 GIL 036248 GIL 036249 GIL 037937 GIL 048661 GIL 043481

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Parameter II P-2-75-500-CA Order No.
GIL 099939 GIL 023660 GIL 096071 GIL 031877 GIL 035372

Fig.
A A B B* C D E F G

Gilbert No.
GRS500BDU03 GRS500BSDU03 GRS500CHDU03 GRS500CHDU03T GRS500SPDU03 GRS500BAFFDU03 GRS500AFMDU03 GRS500EXTDU03T GRS500TRDU03

Fig.
A B B* C D

Gilbert No.
GRS500BDU01 GRS500CHDU01 GRS500CHDU01T GRS500SPDU01 GRS500BAFFDU01

All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin

* Longer Pin Version Contains seal SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288 EAST: Rockaway, NJ WEST: Santa Ana, CA 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G34

Cable & Connectors Connectors

Aluminum Connectors for .500 Cable continued


The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. General Fused Disc .500 Order No.
GIL 072632 GIL 031876 GIL 112658 GIL 023664 GIL 039973

Fig.
A B B* C D

Gilbert No.
GRS500BDU02 GRS500CHDU02 GRS500CHDU02T GRS500SPDU02 GRS500BAFFDU02

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Cerro Cerrofoam GX 3300-CC Comm/Scope Parameter I P-1-75-500-CA Comm/Scope Alumagard AL-75-500-CA CCS Cable Chema-Foam 52200 CCS Cable GID I 54200 Times Alumifoam JT-1500 Times Alumifoam II JT-3500 Scientific Atlanta 20 22-500 Scientific Atlanta Polyethylene 2-500 Order Fig. No.
A B

The Order Below Numbers Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Quantum Reach QR-500-JCA Order No.
GIL 085313 GIL 112563 GIL 077852 GIL 024026

Gilbert No.

Order No.

LRC No.

GIL 023517 GRS500BA01 GIL 023519 GRS500CHA01 GIL 061695 GRS500CHA01T GIL 023521 GRS500SPA01 GIL 024023 GRS500BAFFA01 GIL 037935 GRS500AFMA01 GIL 057116 GRS500EXTA01T GIL 040374 GRS500TRA01

LRC 096273 EMI500K

Fig.
B B* C D

Gilbert No.
GRS500CHQR GRS500CHQRT GRS500SPQR GRS500BAFFQR

B* C D E F G

LRC 096214 EI500K LRC 096213 S1500K LRC 112495 AI500FFK

LRC 096215 EI500KLB

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Trilogy MC2 2101012

Order Fig. No.


A B B* C D

Gilbert No.

Order No.

LRC No.

Order No.

Amphenol No.

Order No.

Cabel Con No.


GIL 095021 GRS500BMC2 GIL 089589 GRS500CHMC2

LRC 109215 EMI500MC2

GIL 094029 GRS500CHMC2T LRC 109214 EI500MC2 GIL 096024 GRS500SPMC2 GIL 109191 GRS500BAFFMC2 LRC 109213 SI500MC2

APL 201517 ACC500CHMC APL 201529 ACC500SPMC

CBC 604557 PI-500-CH-4 CBC 604572 PI-500-SP-4

APL 201514 ACC500BAFFMC CBC 604594 PI-500-BAFF-04

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Quantum Reach QR-500-JCA Order No.
GIL 085313 GIL 112563 GIL 077852 GIL 024026

Fig.
B B* C D

Gilbert No.
GRS500CHQR GRS500CHQRT GRS500SPQR GRS500BAFFQR
All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin 800-433-3765 800-643-2288 EAST: Rockaway, NJ WEST: Santa Ana, CA 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

* Longer Pin Version Contains seal SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

G35

1996 TELEWIRE SUPPLY

Cable & Connectors Connectors

Aluminum Connectors for .540 (QR) Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Quantum Reach QR-540JCA Order Fig. No.
A A B B* C D GIL 112733 GIL 059442 GIL 112574 GIL 059445 GIL 112688

Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

Gilbert No.
GRS540BSQR GRS540CHQR GRS540CHQRT GRS540SPQR GRS540BAFFQR

Order No.
LRC 112894 LRC 112510

LRC No.
EMI540QR EI540QR

Order No.
APL 201522 APL 201534 APL 201546

Amphenol No.
ACC540CHQR ACC540SPQR

Order No.

Cabel Con No.


CBC 200364 PI-540-CH-5 CBC 200367 PI-540-SP-5

ACC540BAFFQR CBC 604597 PI-540-BAFF-5

Aluminum Connectors for .565 (TX) Cable


G
A. Feed-Thru B. Pin Type C. Splice D. "F" Female

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Times Fiber TX10 Semiflex Cable TX10565J Order Fig. No.
B C D GIL 059442 GIL 059445

Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

Gilbert No.
GRS540CHQR GRS540SPQR

Order No.
LRC 149154 LRC 149157

LRC No.
EI565TX SI565TX

Order No.

Amphenol No.

APL 201519 ACC565CHTX APL 201531 ACC565SPTX APL 201543 ACC565BAFFTX

All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin * Longer Pin Version Contains seal SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288 EAST: Rockaway, NJ WEST: Santa Ana, CA 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G36

Cable & Connectors Connectors

Aluminum Connectors for .625 Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

E. "F" Male

F. Extension

G. Cable Terminator
Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Parameter III P3-75-625-CA CCS Cable 66200 Scientific Atlanta 30 32-625 Times Lumifoam III JT-4625 Times T4 Plus 22600 Trilogy 3111011 Order Fig. No.
A B B* C D F GIL 099966 GIL 041944 GIL 050245 GIL 050243 GIL 004657 GIL 101444 GIL 077191

Gilbert No.
GRS625BDU02 GRS625CHDU02 GRS625CHDU02T GRS625SPDU02 GRS625BAFFDU02 GRS625EXTDU02T GRS625TRDU02

Order No.
LRC 081916 LRC 081914 LRC 096267

LRC No.
EMI625K3 EI625K3 SI625K3 EI625K3LB

Order No.

Amphenol No.

Order No.

Cabel Con No.


APL 201514 ACC625CHP3 APL 201526 ACC625SPP3 APL 201538 ACC625BAFFP3

CBC 200262 PI-625-CH-3 CBC 200368 PI-625-SP-3

* Longer Pin Version Contains seal

All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288 EAST: Rockaway, NJ WEST: Santa Ana, CA 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

G37

1996 TELEWIRE SUPPLY

Cable & Connectors Connectors

Aluminum Connectors for .650 (MC2) Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Trilogy MC2 3101011 Order Fig. No.
B B* C GIL 109233 GIL 072155 GIL 072160

Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

Gilbert No.
GRS650CHMC2 GRS650CHMC2T GRS650SPMC2

Order No.
LRC 109227 LRC 109227 LRC 109226

LRC No.
EI650MC2 EI650MC2 SI650MC2

* Longer Pin Version Contains seal

Aluminum Connectors for .700 Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Times Fiber TX10 Semiflex Cable TX10700J Order Fig. No.
B C D APL 201520 APL 201532 APL 201544

Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

Amphenol No.
ACC700CHTX ACC700SPTX ACC700BAFFTX

Order No.
LRC 201440

LRC No.
EI700TX

All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G38

Cable & Connectors Connectors

Aluminum Connectors for .715 Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Quantum Reach QR-715JCA Order Fig. No.
B B* C D GIL 144117 GIL 144441 GIL 144840

Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

Gilbert No.
GRS715CHQR GRS715CHQRT GRS715SPQR

Order No.
LRC 152637 LRC 152636

LRC No.
EI715QR SI715QR

Order No.

Amphenol No.

APL 201523 ACC715CHQR APL 201535 ACC715SPQR APL 201547 ACC715BAFFQR

* Longer Pin Version Contains seal

All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G39

1996 TELEWIRE SUPPLY

Cable & Connectors Connectors

Aluminum Connectors for .750 Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

E. "F" Male

F. Extension

G. Cable Terminator

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Cerro Cerrofoam-GXX 4720-CC Comm/Scope Parameter III P3-75-750-CA CCS Cable GID III 76200 Scientific Atlanta 30 32-750 Times Lumifoam III JT-4750 Times T4 Plus 22700 Order Fig. No. No.
A B B* C D E F G GIL 049529 GIL 031659 GIL 048086 GIL 033729 GIL 035011 GIL 109241 GIL 057118 GIL 044522

Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

Gilbert No.
GRS750BDU01 GRS750CHDU01 GRS750CHDU01T GRS750SPDU01 GRS750BAFFDU01 GRS750AFMDU01 GRS750EXTDU01T GRS750TRDU01

Order No.

LRC No.

Order No.
APL 201515 APL 201527 APL 201539

Amphenol No.
ACC750CHP3 ACC750SPP3 ACC750BAFFP3

Order

Cabel Con No.


LRC 081919 EI750K3 LRC 081920 SI750K3 LRC 081923 AI750FFK3

CBC 200363 PI-750-CH-3 CBC 200369 PI-750-SP-3

LRC 081922 EI750K3LB

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. General Fused Disc MIII 6977615 Order Fig. No.
A B B* C D E F G GIL 049529 GIL 031659 GIL 048086 GIL 033729 GIL 035011 GIL 109241 GIL 057118 GIL 044522

Gilbert No.
GRS750BDU01 GRS750CHDU01 GRS750CHDU01T GRS750SPDU01 GRS750BAFFDU01 GRS750AFMDU01 GRS750EXTDU01T GRS750TRDU01
All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin

* Longer Pin Version Contains seal SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288 EAST: Rockaway, NJ WEST: Santa Ana, CA 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G40

Cable & Connectors Connectors

Aluminum Connectors for .750 Cable


The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Parameter II P-2-75-750-CA Order Fig. No.
A B B* C D E F G GIL 049529 GIL 031659 GIL 048086 GIL 033729 GIL 035011 GIL 109241 GIL 057118 GIL 044522

Gilbert No.
GRS750BDU01 GRS750CHDU01 GRS750CHDU01T GRS750SPDU01 GRS750BAFFDU01 GRS750AFMDU01 GRS750EXTDU01T GRS750TRDU01

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Cerro Cerrofoam GX 3750-CC Comm/Scope Alumagard AL-75-750-CA Comm/Scope Parameter I P1-75-750-CA CCS Cable Chemafoam 72200 CCS Cable GID I 74200 Times Alumifoam JT-1750 Times Alumifoam II JY-3750 Order Fig. No.
B B* C D F* GIL 023661 GIL 057112 GIL 023665 GIL 031895 GIL 057117

Gilbert No.
GRS750CHA01 GRS750CHA01T GRS750-SPA01 GRS750BAFFA01 GRS750EXTA01T

Order No.
LRC 096211

LCR No.
SI750K

LRC 096279 EI750KLB

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. General Fused Disc .750 Order Fig. No.
B B* C

Gilbert No.

GIL 039952 GRS750CHFD04 GIL 039953 GRS750CHFD04T GIL 033730 GRS750SPFD04

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Trilogy MC2 4101010 Order Fig. No.
B B* C D

Gilbert No.

Order No.

LRC No.

Order No.

Amphenol No.

Order No.
CBC 604559 CBC 604574 CBC 604595

Cabel Con No.


PI-750-CH-04 PI-750SP-04 PI-750-BAFF-04

GIL 073499 GRS750CHMC2 GIL 072161 GRS750CHMC2T GIL 072158 GRS750SPMC2 GIL 109242 GRS750BAFFMC2

LRC 109269 EI750MC2 LRC 109269 EI750MC2 LRC 109268 SI750MC2 LRC 109267 AI750FFMC2

APL 201518 ACC750CHMC APL 201530 ACC750SPMC APL 201542 ACC750BAFFMC

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G41

1996 TELEWIRE SUPPLY

Cable & Connectors Connectors

Aluminum Connectors for .840 (TX) Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Times Fiber, 840TX TX10840J Order Fig. No.
B C D GIL 296189 GIL 291365

Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

Gilbert No.
GRS840CHTX GRS840SPTX

Order No.
LRC 292886

LRC No.
SI840T

Order No.

Amphenol No.

APL 201521 ACC840CHTX APL 201533 ACC840SPTX APL 201545 ACC840BAFFTX

* Longer Pin Version

Aluminum Connectors for .860 (QR) Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Quantum Reach QR-860JCA Order Fig. No.
B B* C D F GIL 059452 GIL 112352 GIL 059453 GIL 059449 GIL 112782

Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

Gilbert No.
GRS860CHQR GRS860CHQRT GRS860SPQR GRS860BAFFQR GRS860EXTQRT

Order No.
LRC 067372 LRC 112353

LRC No.
EI860QR SI860QR

Order No.
APL 201524 APL 201536 APL 201548

Amphenol No.
ACC860CHQR ACC860SPQR ACC860BAFFQR

Order No.
CBC 200365 CBC 200370

Cabel Con No.


PI-860-CH-5 PI-860-SP-5

* Longer Pin Version

All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G42

Cable & Connectors Connectors

Aluminum Connectors for .875 Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

E. "F" Male

F. Extension

G. Cable Terminator
Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Parameter III P3-75-875-CA CCS Cable 86200 Scientific Atlanta 3032-875 Times Lumifoam III JT-4875 Times T4 Plus 22800 Order Fig. No.
B B* C D F GIL 042759 GIL 050246 GIL 050242 GIL 099996 GIL 100786

Gilbert No.
GRS875CHDU02 GRS875CHDU02T GRS875SPDU02 GRS875BAFFDU02 GRS875EXTDU02T

Order No.

LRC No.

Order No.
APL 201516 APL 201528 APL 201540

Amphenol No.
ACC875CHP3 ACC875SPP3 ACC875BAFFP3

Order No.

CableCon No.

LRC 102131 EI875K3 LRC 096269 SI875K3

CBC 604554 PI-875-CH-3 CBC 604569 PI-875-SP-3

Aluminum Connectors for 1.000 Cable


The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Parameter III P3-75-1000-CA Times Lumifoam III Times T4 Plus Trilogy/Capscan 4 Order Fig. No.
B B* C D GIL 037931 GIL 056289 GIL 037932 GIL 094299

JT-41000 22900 6111011 Gilbert No.


GRS1000CHDU01 GRS1000CHDU01T GRS1000SPDU01 GRS1000BAFFDU01

Order No.

Amphenol No.

Order No.

Cabel Con No.

APL 202440 ACC-1000CHT10 APL 202439 ACC-1000SPT10

CBC 604555PI-1000-CH-3 CBC 604570PI-1000-SP-3

* Longer Pin Version SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288

All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin EAST: Rockaway, NJ WEST: Santa Ana, CA 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

G43

1996 TELEWIRE SUPPLY

Cable & Connectors Connectors

Aluminum Connectors for 1.000 (MC2) Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Trilogy MC2 5101019 Order Fig. No.
B* C D

Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

Gilbert No.

Order No.

LRC No.

Order No.

Amphenol No.

Order No.

Cabel Con No.

GIL 094302 GRS1000CHMC2T GIL 099932 GRS1000SPMC2

LRC 152635 EI1000MC2 LRC 152634 SI1000MC2

APL 202435 ACC-1000CHMC APL 202436 ACC-1000SPMC

CBC 604560 PI-1000-CH-04 CBC 604575 PI-1000-SP-04 CBC 604596 PI-1000-BAFF-04

Aluminum Connectors for 1.125 (QR) Cable

A. Feed-Thru

B. Pin Type

C. Splice

D. "F" Female

G
The Order Numbers Below Fit the Following Cables Cable Mfg./Type Mfg. Part No. Comm/Scope Quantum Reach QR-1125-JCA Order Fig. No.
B B* C
Illustrations shown above are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc.

Gilbert No.

Order No.

Amphenol No.

GIL 091961 GRS1125CHQR GIL 112785 GRS1125CHQRT GIL 091962 GRS1125SPQR

APL 202438 ACC-1125-CH-QR APL 202937 ACC-1125-SP-QR

* Longer Pin Version SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX 800-433-3765 800-643-2288 EAST: Rockaway, NJ WEST: Santa Ana, CA

All Gilbert and Amphenol are 3 piece All Gilbert extension connectors have long pins All LRC and Cable Con are 2 Piece All LRC, Amphenol and Cable Con Connectors come standard with long pin 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G44

Cable & Connectors Adapters

Adapter-Right Angle to Equipment

Ordering Information - LRC Order No.


LRC 040738 LRC 040739 LRC 040740

Mfg. No.
EU90 EU90-3 EU90-4.5

Description
no extension 3" extension 4.5" extension

Description 90 degree coaxial connector designed especially for pedestal type installations where space restrictions require right angle connections between coaxial cables. Ordering Information - Gilbert Order No.
GIL 022320 GIL 043063 GIL 072922 GIL 057345 GIL 057122 GIL 058741

Ordering Information - Amphenol Order No.


APL 201549 APL 201550 APL 201551 APL 201552

Mfg. No.
ACC-90 ACC-901.5 Ext ACC-903 Ext ACC-904.5 Ext ACC-906 Ext

Description
No extension 1-1/2" extension 3" extension 4.5" extension 6"extension

Mfg. No.
GP90 GP90T GP90-3.0 GP90-3.0T GP90-4.5 GP90-4.5T

Description
no extension no extension, long pin 3" extension long pin, 3" extension 4.5" extension long pin, 4.5" extension

APL 201553

Ordering Information - Cabel Con Order No.


CBC 200358 CBC 200359

Mfg. No.
L-90 L-90-W/1.5

Description
No extension 1-1/2" extension

Adapter-Right Angle Connector to Equipment


G
Ordering Information - Gilbert Order No.
GIL 076286

Mfg. No.
GP90S GP90ST

Description
no extension no extension, long pin

Description Same as above except body need not be rotated during installation.

GIL 094296

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G45

1996 TELEWIRE SUPPLY

Cable & Connectors Adapters

Adapter-180 Connector to Equipment

Ordering Information - LRC Order No.


LRC 040738 LRC 040739 LRC 040738 LRC 040740 LRC 040738

Mfg. No.
EU90 (2 ea.) EU90-3.0 & EU90 EU90-4.5 & EU90

Description
ext. length 5.18 ext. length 3.0

ext. length 4.5

Ordering Information - Amphenol Description Provides connection between amplifier and cable connector in restricted space. Order No.
APL 201556 APL 201557

Mfg. No.
ACC-1803 EXT ACC-1804.5 EXT ACC-1806 EXT

Description
3" extension 4.5" extension 6" extension

Ordering Information - Gilbert Order No.


GIL 023522 GIL 050244 GIL 057121 GIL 057401 GIL 057120 GIL 058742

APL 201558

Mfg. No.
GPPA GPPAT GPPA-3.0 GPPA-3.0T GPPA-4.5 GPPA-4.5T

Description
ext. length 5.18" ext. length 5.18", long pin ext. length 3.0" ext. length 3.0", long pin ext. length 4.5" ext. length 4.5", long pin

Ordering Information - Cabel Con Order No.


CBC 202426 CBC 202427 CBC 202428 CBC 202429

Mfg. No.
L-180-W/3" L-180-W/6" L-180-W/9" L0180-W/12

Description
3" extension 6" extension 9" extension 12" extension

Male Splice Adapter Rotational


Description Housing to housing coupling connector, eliminates the need for coaxial jumpers and permits cascadability of taps, etc. Ordering Information - LRC Order No.
LRC 040745 LRC 112581

Mfg. No.
ETE625R ETE625LR

Description
standard with V grooves

Ordering Information - Gilbert Order No.


GIL 022688 GIL 112578 GIL 112580 GIL 041799 GIL 076287 GIL 074210

Ordering Information - Amphenol Description


standard with monel gasket with monel gasket, long pin with long pin with V grooves with V grooves, long pin

Mfg. No.
GKSKSM GKSKSMG GKSKSMGT GKSKSMT GKSKSMV GKSKSMVT

Order No.
APL 201559

Mfg. No.
ACCHSGHSG

Description
standard

Ordering Information - Cabel Con Order No.


CBC 200360

Mfg. No.
KS-KS-M-0000

Description
standard

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G46

Cable & Connectors Adapters

Male Splice Adapter Non-Rotational


Ordering Information - LRC Order No.
LRC 040744

Mfg. No.
ETE625

Description
standard, long pin

Ordering Information - Gilbert Description Housing to housing coupling connector, eliminates the need for coaxial jumpers and permits cascadability of taps, etc. Order No.
GIL 068185 GIL 057119

Mfg. No.
GKSKSMNR GKSKSMNRT

Description
standard with long pin

Female Splice Adapter


Description Used to splice two chassis connectors. Enables splicing of any type cable to any other with minimum losses. Ordering Information - Gilbert Order No.
GIL 022687 GIL 022686

Mfg. No.
GKSKSF GKSKSFS

Description
standard high current capability

Adapter - Splice Block


G
Ordering Information - LRC Order No.
LRC 040742 LRC 071702

Mfg. No.
HSB TSB

Port Spacing
1.50" through splice only

Ordering Information - Amphenol Description Universal splice for two connectors. Allows for in-line and right angle splicing. Ordering Information - Gilbert Order No.
GIL 031073 GIL 076289 GIL 106714

Order No.
APL 201560

Mfg. No.
ACCPSB

Port Spacing
2.25

Ordering Information - Cabel Con Order No.


CBC 200354

Mfg. No.
GSPB GSPB-2.0 GSPB-2.75

Mfg. No.
PSPB

Port Spacing
2.25

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G47

1996 TELEWIRE SUPPLY

Cable & Connectors Adapters

Splice - In Line or Right Angle Adapter


Description Splices different diameters of coaxial of cables with chassis connections. Can be used in right angle turn for pedestal type installations where space is restricted. Ordering Information - Gilbert Order No.
GIL 022905

Mfg. No.
GP90/180

Extension Adapter-Connector to Equipment


Ordering Information - Gilbert Order No.
GIL 031880 GIL 030483 GIL 031088

Mfg. No.
GEXT-3-1 GEXT-6-1 GEXT-9-1 GEXT-12-1

Dimension
3.18" 6.0" 9.0" 12.0"

Description Adapter provides extended length when sufficient cable is not available for installation. Can be installed with any pin type or .412 and .500 feed thru type connector.

GIL 031089

Ordering Information - Amphenol Order No.


APL 201563 APL 201564 APL 201565 APL 201566 APL 201567 APL 201568

Mfg. No.
ACC-1.5 EXT ACC-3 EXT ACC-4.5 EXT ACC-6 EXT ACC-9 EXT ACC-12 EXT

Dimension
1.5" extension 3" extension 4.5" extension 6" extension 9" extension 12" extension

Adapter-Chassis Mounting Connector to "F" Series Female

Description Converts pin type connector to "F" series female. 5/8-24 threads. Ordering Information - Gilbert Order No.
GIL 037113

Mfg. No.
GCHBAFFKS

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G48

Cable & Connectors Adapters

Adapter-Chassis Mounting Connector to "F" Series Male


Description Converts pin type connector to "F" series male. Ordering Information Order No.
GIL 044447

Mfg. No.
G-CH-AFM

"F" Female-'KS' Adapter


Ordering Information Order No.
GIL 004656 GIL 049415 LRC 040741

Mfg. No.
GF625CH GF625CHT* F625E ACC625CH F625CH000

Manufacturer
Gilbert Gilbert LRC Amphenol Cabel Con

Description F series to KS entry.

APL 201562 CBC 200356

"KS" Port Terminator


Ordering Information Order No.
GIL 022030 GIL 041800

Mfg. No.
GTRM GTRMT* 625TRB* ACCTRM TRM-00000000

Manufacturer
Gilbert Gilbert LRC Amphenol Cabel Con

Description Designed to terminate 60 cycle and RF signals on unused equipment ports.

LRC 040743 APL 201561 CBC 200357

"F" Female-'KS' Adapter AC (60 Hz) Power Blocking

Ordering Information Order No.


GIL 037940 GIL 076086 LRC 109246

Mfg. No.
GF625CHDCB GF625CHDCBT* F625BE

Manufacturer
Gilbert Gilbert LRC

Description F series to KS entry. Terminates 60 cycle AC.

* Long pin version


Illustrations shown are pictured as a reference only. Actual product may vary from these illustrations. Artwork 1996 Gilbert Engineering Co., Inc. 800-433-3765 800-643-2288 EAST: Rockaway, NJ WEST: Santa Ana, CA 800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

G49

1996 TELEWIRE SUPPLY

Cable & Connectors Cable Pulling Lubricants

Heat Shrink Tubing


CANUSA
Description CFTV heat shrinkable tubing is designed specifically to meet the needs of the CATV industry. CFTV tubing provides an absolutely waterproof seal and mechanical protection. CFTV tubing is easy to install and allows clean and easy connector re-entry. The unique sealant that internally coats CATV tubing provides selective strippability and a strong watertight bond to cable and cable jacket, yet, strips fast and clean for re-entry to the connector splice. Heat indicator lines disappear when tubing has fully recovered producing an error free installation without scorching or cable damage. Features Shrink ratio of 3 to 1 Environmentally seals and mechanically protects 7 standard sizes Adhesive flows smoothly and will not drip Selective Strippability to meet CATV industry needs Balanced system: 3 synchronized components; stripes change color, tubing shrinks, and sealant flows simultaneously Installation Tests When adequate heat is applied, heat reactive stripes change color: blue to black When color has changed, tubing is fully recovered When color has changed, sealant has achieved balanced flow Adhesive flows without dripping No cracks or splitting No surface charring during installation

Ordering Guidelines To order, specify product type, size, length, and coating.

CFTV - 1300 - 48 - T
Product Type Size Length CATV Sealant Standard Color Black with blue heat indicating stripes. Standard Length 48" lengths or as shown in dimension table Also available in 6", 12" and 24" lengths.

Ordering Information
Order No.
CUS 600356 CUS 600350 CUS 600351 CUS 600352 CUS 600353 CUS 600354 CUS 600355

Mfg. No.
CFTV-750 CFTV-1100 CFTV-1300 CFTV-1500 CFTV-1700 CFTV-2050 CFTV-2750

Standard Length
48" (1.22 meters) 48" (1.22 meters) 48" (1.22 meters) 48" (1.22 meters) 48" (1.22 meters) 48" (1.22 meters) 48" (1.22 meters)

Internal Dia. Minimum (D)


0.75" 1.1" 1.3" 1.5" 1.7" 2.05" 2.75" 19mm 27.9mm 33mm 38.1mm 43.2mm 52.1mm 69.8mm

Internal Dia. Maximum (d)


0.22" 0.4" 0.4" 0.5" 0.5" 0.75" 1" 5.6mm 10.2mm 10.2mm 12.7mm 12.7mm 19mm 25.4mm

Nominal Total Wall Application Range Thickness (W) for General Use (Dia.)
0.08" 0.08" 0.08" 0.08" 0.08" 0.08" 0.08" 2mm 2mm 2mm 2mm 2mm 2mm 2mm .24-.65" .45-1.0" .45-1.2" .55-1.4" .55-1.6" .82-1.8" 1.2-2.5" 6.0-16.5mm 11.5-25.0mm 11.5-30.0mm 14.0-35.0mm 14.0-40.0mm 21.0-45.0mm 30.0-63.0mm

See page K-138 for trunk cable O.D. chart.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G50

Cable & Connectors Heat Shrink

Heat Shrink Tubing Choosing the Proper Size


The heat shrink tubing must be large enough to fit over the connector and still shrink tightly to the cable. To properly affect a waterproof seal, lengths should be approximately 2" to 3" longer than a feedthrough or chassis mount connector and 4" to 6" longer than a splice connector. .412 Cable Canusa No.
CFTV-1300 CFTV-1100

.650 Cable (MC2) Canusa No. Connector Mfg.


CFTV-1700 CFTV-1300 Gilbert LRC

Connector Type
GRS650 series 650MC2 series

.710 Cable (TX Series) Canusa No. Connector Mfg.


CFTV-1700 Gilbert

Connector Type
GRS710 series

Connector Mfg.
Gilbert Gilbert LRC

Connector Type
GP412 series GRS412 series EM (F) 412 K/W series

.750 Cable Canusa No.


CFTV-1700

Connector Mfg.
Gilbert Gilbert LRC

Connector Type
GP750CGHA GP750CHDU GRS750 series EM(F) 750 K/W series

CFTV-1300

.440 Cable (MC 2) Canusa No. Connector Mfg.


CFTV-1300 CFTV-1100 Gilbert LRC

Connector Type
GRS440 series 440MC2 series

.750 Cable (MC2) Canusa No. Connector Mfg.


CFTV-1700 CFTV-1300 Gilbert LRC

Connector Type
GRS750MC2 series 750MC2 series

.480 Cable (TX Series) Canusa No. Connector Mfg.


CFTV-1300 Gilbert

Connector Type
GRS480 series

.840 Cable Canusa No.


CFTV-2050 CFTV-1700

Connector Mfg.
Gilbert LRC

Connector Type
GRS840 series 840 TX series

.500 Cable Canusa No.


CFTV-1300 CFTV-1500 CFTV-1700

Connector Mfg.
LRC Gilbert Gilbert

Connector Type
EM(F) 500 K/W series GP500CHA GRS500CHDU GRS500 series

.860 Cable (Quantum Reach) Canusa No. Connector Mfg.


CFTV-2050 CFTV-1700 Gilbert LRC

Connector Type
GRS860 series 860 QR series

G
.500 Cable (MC ) Canusa No. Connector Mfg.
CFTV-1500 CFTV-1300 Gilbert LRC
2

.875 Cable Canusa No.


CFTV-1700

Connector Mfg.
Gilbert LRC

Connector Type
GRS875 series 875 K series

Connector Type
GRS500MC2 series 500MC2 series

.1000 Cable Canusa No.


CFTV-2050 CFTV-1700

Connector Mfg.
Gilbert LRC

Connector Type
GRS1000 series 1000 K & W series

.540 Cable (Quantum Reach) Canusa No. Connector Mfg.


CFTV-1500 CFTV-1300 Gilbert LRC

Connector Type
GRS540 series 540 QR series

.1000 Cable (MC2) Canusa No. Connector Mfg.


CFTV-2050 CFTV-1700 Gilbert LRC

Connector Type
GRS840 series 840 TX series

.565 Cable (TX Series) Canusa No. Connector Mfg.


CFTV-1500 CFTV-1300 Gilbert LRC

Connector Type
GRS565 series 565 TX series

.1125 Cable (Quantum Reach) Canusa No. Connector Mfg.


CFTV-2750 CFTV-2050 Gilbert LRC

Connector Type
GRS1125 series 1125 QR series

.625 Cable Canusa No.


CFTV-1700 CFTV-1300

Connector Mfg.
Gilbert LRC

Connector Type
GRS625 series 625 K series

.1160 Cable (TX Series) Canusa No. Connector Mfg.


CFTV-2050 CFTV-2050
EAST: Rockaway, NJ WEST: Santa Ana, CA

Connector Type
GRS1160 series 1160 TX series
MIDWEST: Rolling Meadows, IL 800-428-7596

Gilbert LRC
800-458-4524 800-227-2869

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

G51

1996 TELEWIRE SUPPLY

Cable & Connectors Connectors

DigiCon Connector
ANTEC
Description Marketplace needs are pushing the communications industry towards the convergence of video, voice and data. Broadband network providers are engineering their systems for expanded bandwidth, two-way interactivity and digital and/or compressed digital signals. ANTECs new Digicon "F" Connector is the smart connector for subscriber interfaces in your advanced broadband networks. Features High performance, sealed drop connector Superior mechanical and electrical specifications Conical swedge provides an efficient, environmental seal One connector for Type 6 and one connector for Type 59 Unique installation tool for both connector types Ordering Information
Order No.
DIG 202475 DIG 202474 DIG 202480 DIG 202481 DIG 202478 DIG 202479 DIG 202476 DIG 202477

Mfg. No.
D6 D59 RTC360-59/6FB RTC-Holster PSR59/6 PSC59/6 SSBS SSGL

Description
Digicon universal 6 series F connector Digicon universal 59 series F connector Digicon connector compression tool Digicon compression tool holster Digicon coaxial cable prep tool Digicon cable prep tool replacement blade Digicon sealing sleeves short black Digicon sealing sleeves long gray

Digicon Connectors have many advantages over the standard F-fittings Digicon connectors were specifically designed to be used with the patented RTC 360 Radial Tamper Crimp tool. The connectors were designed with Internal Sealing Rings. When conicaly swedged, these rings from an ORing out of the cables outer jacket. The internal rings reduce radiation leakage, provide an excellent seal for waterproofing, and improve the pull-out strength of theconnector. F-Conn connectors are manufactured with a lenghthened internal ferrule to support the outer radial swedge and provide a strong electrical connection. The inner wall of the connector is tapered. This taper aids in the swedging process by ensuring that the connector will not collapse under the axial pressure of the swedge. Digicon Connectors have a rubber ring in the hex nut for protection against water intrusion. The Digicon Connector system significantly reduces radiation leakage when compared to standard hex crimps

The Conn ector for Digital Tra nsmission

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G52

Cable & Connectors EZF Conectors

EZ Twist Inoor Coaxial Drop Connector


RAYCHEM

EZF Coaxial Drop Cable Connector


RAYCHEM

Description A unique twist-on feature of the EZ Twist connector makes easy installation possible on all cables commonly used in the home, even fire-retardant cables with light jackets. A polymeric ring, designed for cable retention, secures the cable to connector interface. The outer polymeric shell seats the ring, and locks the assembly on the port. An installation aid is provided to assist in terminating the connector to the cable. Made of clear plastic, the aid allows visual inspection, proper cable location in the connector, and correct center conductor length. EZ Twist connectors have many of the features installers have come to rely upon with the EZF connector. They are color coded red for RG59 cable and blue for RG6 cable. The cable is easily prepared with the EZF-T cable preparation tool. EZ Twist connectors save labor and expense while providing high quality, dependable, and consistent terminations. EZ Twist connectors are packaged in bags of 100, with 4 install aids and 20 subscriber labels. Ordering Information
Order No.
RYC 144291

Description Raychems EZF connector is designed to reduce system RF leakage, maintenance calls and inventory. Prepackaged in an easy-to-handle, pocket-sized cassette, only three connector types are needed; one for RG59 cable, one for RG6 and one for RG11. The EZF connector line has color-coded cassettes and ferrules for easy identification; blue for EZF-6, red forEZF-59, and black for EZF-11. No crimp tools are needed; a common 7/16 wrench will tighten and seal the EZF-6 and 59 connector, 5/8" for EZF-11.. Environmentally sealed for aerial and pedestal applications. Each cassette of RG59 and RG6 connectors contains 12 EZF connectors; the RG11 cassette contains 6 connectors. EZF connector is compatible with ports that are .280 or longer.

Ordering Information
Order No.
RYC 082399 RYC 104483

Mfg. No.
EZF-59 EZF-59L

Description
RG59 connector with black sealing sleeves for F ports less than .450" long RG59 connector with gray sealing sleeves for F ports .450" or longer RG6 connector with black sealing sleeves for F ports less than .450" long RG6 connector with gray sealing sleeves for F ports .450" or longer RG11 connector with black sealing sleeves for F ports .275" long

Mfg. No.

Description
RYC 144018 EZF-6

EZ Twist 59-S/T for RG59 single braid and tri--shield, color coded red EZ Twist 59-Q EZ Twist 6-S/T for RG59 quad shield, color coded light red for RG6 single braid and tri-shield, color coded blue for RG6 quad shield, color coded light blue

RYC 144021 RYC 144290

RYC 144017

EZF-6L

RYC 095178

EZF-11

RYC 144020

EZ Twist 6-Q

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G53

1996 TELEWIRE SUPPLY

Cable & Connectors Connectors

"F" Connectors

LRC for RG59 drop cable Order No. Mfg. No. Hex Size
.324 .324

Ordering Information Gilbert for RG59 drop cable Order No. Mfg. No. Hex Size
.326

RG59, up to 78% braid LRC 040952 F59CHI LRC 100557 RG59, quad shield LRC 084422 RG59, headend cable LRC 112593 F59CHI

F59QS

.324

RG59, up to 78% braid GIL 035324 GF-59-AH-S/290 RG59, greater than 78% braid GIL 040749 GF-59-AH-S/312 RG59, quad shield GIL 040749 GIL 060455 RG59, headend cable GIL 060455 GIL 043956

F59HEC

.324

LRC for RG6 drop cable


.326

Order No.
GF-59-AH-S/312 GF-59-AH-S/342 .326 .326 RG6, up to 78% braid LRC 040951 LRC 100533 GF-59-AH-S/342 GF-59-AH-S/357 .326 .384 RG6, quad shield LRC 089747

Mfg. No.
F59CHI F59CH

Hex Size
.324 .324

F59QS

.360

Gilbert for RG6 drop cable Order No.


RG6, up to 40% braid GIL 050080

LRC for RG7 drop cable Hex Size


.326

Mfg. No.
GF-6-AH-S/312

Order No.
For all RG7 LRC 122827

Mfg. No.
F7CH

Hex Size
.470

RG6, 41% to 78% braid GIL 050080 GF-6-AH-S/312 GIL 103779 GF-6-AH-S/322

.326 .326

LRC for RG11 drop cable Order No. Mfg. No. Hex Size
.470

RG6, greater than 78% braid GIL 035325 GF-6-AH-S/342 RG6, quad shield GIL 035325 GF-6-AH-S/342 GIL 041667 GF-6-AH-S/357

.326 .326 .384

RG11, up to quad sheild LRC 087204 F11QS

Just Drop Order No. Mfg. No. Hex Size


.324

Gilbert for RG11 drop cable Order No. Mfg. No. Hex Size
.100 & .475

RG59, up to 67% braid JST 202338 F59 RG59, from 67% braid up to quad sheild JST 202339 F59QS RG6, up to 67% braid JST 202340

RG11, geater than 40% braid, with pin GIL 043957 GF-11-AH-S/460 RG11, quad sheild, with pin GIL 060510 GF-11-AH-S/480

.324

.100 & .475

F6

.324

Gilbert - Universal "F" Connectors


One connector fits all RG59 cables, one connector fits all RG6 cables

RG6, from 67% braid up to quad sheild JST 202341 F6QS

.324

Order No.
GIL 119011 GIL 119012

Mfg. No.
GF-59-AH-S/USA GF-6-AH-S/USA

Hex Size
.360 .360

These tables are for reference purposes only. Installation procedures and manufacturer variances may affect the type of connector to use.

For drop cable see Section G - Cable & Connectors


800-458-4524 800-227-2869 MIDWEST: Rolling Meadows, IL 800-428-7596

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

1996 TELEWIRE SUPPLY

G54

Cable & Connectors Connectors

F-81 Connectors
REGAL

F-81 Connectors

Features 1 GHz bandwidth with low loss characteristics Flat F ports on both ends assure proper contact and improve EMI shielding Two lengths to accommodate in-line splicing, or wall plate and demarcation plate applications Nickel plated brass for increased corrosion protection and installation ease Description Regal's F-81 connectors feature an industry exclusive - two flat F ports. Flat ports improve EMI shielding with a more uniform ground, ensuring a quality connection for years to come. Available in 1.1" and 1.4" lengths, these F-81 connectors accommodate in-line splicing or wall plate and demarcation plate applications. Usable minimum length of either end is 1/2" to accommodate sealing sleeves and deep F male connectors. Ordering Information

Ordering Information - Gilbert Order No.


GIL 004705 GIL 044453 GIL 044454

Mfg. No.
GF-81 GF-81A GF-81S

Length
1.06 0.81 1.13

Hardware
yes no no

Ordering Information - LRC Order No.


LRC 088743 LRC 050544

Mfg. No.
F-81 F-81/ hdw

Length
0.90 0.90

Hardware
no yes

Ordering Information - Gilbert Length


1.10 1.40

Order No.
REG 127761 REG 127760

Mfg. No.
RF-81 RF-81H

Hardware
no yes

Order No.
JST 202281 JST 202282 JST 202283 JST 202336

Mfg. No.
JD-81 JD-81HDW JD-81D JD-NUTS

Length
0.84 0.84 0.84

Hardware
no yes yes

"D" flat 1 side nuts only for F-81

Specifications
Bandwith MHz 5-400 Insertion loss .10 max (dB) Return Loss min. (dB) * RF-81 only 20 400-500 .10 18 500-550 .16 17 550-600 .16 16 600-1000 .25 15 (14)*

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G55

1996 TELEWIRE SUPPLY

Cable & Connectors Adapters & Coaxial Connectors

RG-213 Connector
Description RG 213 Male 50 Ohm N Type Connector Ordering Information Order No.
PIC 101498 GIL 057077

Mfg. No.
NMA234 GIL GN821AHS/460

RG-214 Connector
Description RG 214 Male 50 Ohm N Type Connector Ordering Information Order No.
GIL 072913

Mfg. No.
GN-214AHS/480

N Type Adapters 50 Ohm Impedance


Ordering Information Order No.
APL 040479

Mfg. No.
82-100

Male to Male Splice

Ordering Information Order No.


APL 040480

Mfg. No.
82-101

Female to Female Splice

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G56

Cable & Connectors Cross References

Cable to Connector Cross Reference COMM /SCOPE DROP CABLE TO GILBERT CONNECTOR
Connector part numbers for this cross reference were supplied by the respective connector manufacturer. These guides are not a guarantee or an endorsement, but rather an aid in connector selection. It is the customer's responsibility to select connectors for a specific cable by calling the manufacturer of the connector.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G57

1996 TELEWIRE SUPPLY

Cable & Connectors Equipment for Line Vehicles

Cable to Connector Cross Reference


BELDEN DROP CABLE TO LRC CONNECTOR

Connector part numbers for this cross reference were supplied by the respective connector manufacturer. These guides are not a guarantee or an endorsement, but rather an aid in connector selection. It is the customer's responsibility to select connectors for a specific cable by calling the manufacturer of the connector.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

1996 TELEWIRE SUPPLY

G58

Cable & Connectors

Cable to Connector Cross Reference


BELDEN DROP CABLE TO GILBERT CONNECTOR

Connector part numbers for this cross reference were supplied by the respective connector manufacturer. These guides are not a guarantee or an endorsement, but rather an aid in connector selection. It is the customer's responsibility to select connectors for a specific cable by calling the manufacturer of the connector.

SOUTHEAST: Norcross, GA SOUTHWEST: Irving, TX

800-433-3765 800-643-2288

EAST: Rockaway, NJ WEST: Santa Ana, CA

800-458-4524 800-227-2869

MIDWEST: Rolling Meadows, IL 800-428-7596

G59

1996 TELEWIRE SUPPLY

Das könnte Ihnen auch gefallen