Sie sind auf Seite 1von 90

Industrial Cables and Wires

31472-00e-A000.indd 33

03.04.2009 7:40:05 Uhr

Photo: HELUKABEL

Flexible Control Cables

A1

31472-00e-A001.indd 34

03.04.2009 7:39:58 Uhr

Flexible Control Cables


For generations people have tried to build
machines and plants which take on different
functions. To raise, sink, slide, drill, transport and
much more, and have attained fantastic results.

Today we control, inform, weld, pack and transport


automatically by electric control and data cables.
These cables are necessary to ensure a frictionless
ow of data and material. We are able to offer
most of these cables for many applications.
On the following pages we present cables for the
corresponding applications.
If you cant nd a suitable cable in our catalogue,
we can fabricate this special cable on request
already from 100 m or maybe we can offer you a
similar cable from our stock.

HELUKABEL has one of the biggest stocks of


special and standard cables in Germany and
excellent logistics and wants to prove itself every
day.

Stocks in:
Hemmingen/Stuttgart, Neuenhagen/Berlin,
Pleia/Chemnitz, Windsbach/Nuremberg.

A2

31472-00e-A002.indd 35

03.04.2009 7:39:47 Uhr

Masters: - ProductGroupID: - Layout: - Umbruch:

Contents
Description

Page

PVC Control Cables


JZ-500,flexible, number coded, meter marking ................................................................................................................................
JZ-500 COLD,flexible at low temperature, number coded, meter marking ............................................................................................................
JZ-500,flexible, number coded, blue cores, meter marking ..................................................................................................................
JZ-500,flexible, number coded, red cores, meter marking ...................................................................................................................
JZ-500 orange,flexible, orange cores, control cable for interlocking purposes, meter marking .........................................................................
H05VV5-F (NYSLY-JZ),flexible, number coded, oil resistant, meter marking .......................................................................................
(H)05VV5-F ((N)YSLY-JZ),flexible, number coded, oil resistant, meter marking ........................................................................................
JZ-750,flexible, number coded, 750V, meter marking .............................................................................................................................
JZ-600,flexible, number coded, 0,6/1kV, meter marking ...............................................................................................................................
H03VV-F,according to DIN VDE 0281 ............................................................................................................................................
H05VV-F,according to DIN VDE 0281 ............................................................................................................................................
H05VV-F,according to DIN VDE 0281 ............................................................................................................................................
JB-500,flexible, colour coded, meter marking ..................................................................................................................................
JB-750,flexible, colour coded, 750V, meter marking ...............................................................................................................................
JB-750 yellow,flexible, colour coded, 750V, connection cable for warning indication, meter marking ......................................................................
F-CY-OZ (LiY-CY),flexible, Cu-screened, EMC-preferred type, meter marking .........................................................................................
F-CY-JZ,flexible, Cu-screened, EMC-preferred type, meter marking .......................................................................................................
H05VVC4V5-K (NYSLYCY-JZ),flexible, number coded, oil resistant, EMC-preferred type, meter marking ..................................................
(H)05VVC4V5-K ((N)YSLYCY-JZ),number coded, screened, oil resistant, EMC-preferred type, meter marking ................................................
Y-CY-JZ,flexible, CU-screened, transparent, EMC-preferred type, meter marking ............................................................................................
SY-JZ,flexible, number coded, with steel wire braiding, meter marking ....................................................................................................
JZ-600-Y-CY,flexible, number coded, 0,6/1kV, Cu screened meter marking, EMC-preferred type ............................................................................
Y-CY-JB,flexible, CU-screened, transparent, EMC-preferred type, meter marking ...........................................................................................
SY-JB,flexible, colour coded, with steel wire braiding, meter marking .....................................................................................................

A 10
A 11
A 12
A 14
A 15
A 17
A 19
A 20
A 21
A 22
A 23
A 24
A 25
A 27
A 29
A 31
A 32
A 34
A 36
A 38
A 40

PUR Control Cables


JZ-500 PUR,tear and coolant resistant, meter marking ...............................................................................................................................
PUR-JZ,tear and coolant resistant, increased oil resistant, meter marking ........................................................................................................
PUR-ORANGE,high abrasion, coolant resistant, meter marking .....................................................................................................................
PUR-YELLOW,PVC-inner jacket, high abrasion, coolant resistant, meter marking ................................................................................................
H05 BQ-F / H07 BQ-F* (NGMH11Y),EPR-insulated power cables with PUR jacket .................................................................................
UNIPUR ,flexible at low temperature, with customer markings, halogen-free, wear resistant, robust, meter marking ...............................................
PUR-750,halogen-free, meter marking ........................................................................................................................................................
JZ 500-FC-PUR,EMC-preferred type, tear and coolant resistant, screened, without inner sheath, meter marking .......................................................
F-C-PUR-JZ,tear and coolant resistant, Cu-screened, without inner sheath, increased oil resistant, EMC-preferred type, meter marking ..........................
Y-C-PUR-JZ,tear and coolant resistant, Cu-screened, with inner sheath, increased oil resistant, EMC-preferred type, meter marking ............................
UNIPUR-CP,flexible at low temperature, with customer markings, halogen-free, wear resistant, robust, screened, EMC-preferred type, meter marking ........
PUR-C-PUR,Cu-screened, extrem conditions, halogen-free, EMC-preferred type, meter marking ................................................................................

A 43
A 44
A 46
A 47
A 48
A 49
A 51
A 52
A 54
A 56
A 58
A 60

A3

A 6
A 8
A 9

Masters: - ProductGroupID: - Layout: - Umbruch:

Contents
A
Description

Page

Halogen-free Control Cables


JZ-500 HMH,flexible control cable, halogen-free, extremely fire resistant, oil resistant1), meter marking .............................................................
MEGAFLEX 500,halogen-free, flame retardant, oil-resistant, UV-resistant, flexible, meter marking ..............................................................
JZ-600 HMH,flexible control cable, halogen-free, extremely fire resistant, oil resistant1), 0,6/1kV, meter marking .......................................................
JB-500 HMH,flexible control cable, coloured core, halogen-free, extremely fire resistant, oil resistant1), meter marking ..........................................
(H)03 Z1Z1-F,halogen-free, meter marking ..................................................................................................................................................
(H)05 Z1Z1-F,halogen-free, meter marking ..................................................................................................................................................
JZ-500 HMH-C,flexible control cable, halogen-free, extremely fire resistant, oil resistant1), Cu-screened, EMC-preferred type, meter marking ..............
MEGAFLEX 500-C,halogen-free, flame retardant, oil-resistant, UV-resistant, flexible, screened, EMC-preferred types, meter marking ..................
JZ-600 HMH-C,flexible control cable, halogen-free, extremely fire resistant, oil resistant 1), 0,6/1kV, screened, EMC-preferred type, meter marking ...........
JB-500 HMH-C,flexible control cable, coloured core, halogen-free, screened, extremely fire resistant, oil resistant1), EMC-preferred type, meter marking

A 62
A 64
A 66
A 68
A 69
A 70
A 71
A 73
A 75
A 77

PVC Control Cables for Intrinsically Safe Circuits


OZ-BL,outer jacket blue, intrinsic safety, flexible, meter marking ................................................................................................................
OZ-BL-CY,outer jacket blue, intrinsic safety, flexible, EMC-preferred type, meter marking .................................................................................
OB-BL-PAAR-CY,outer jacket blue, intrinsic safety, EMC-preferred type, meter marking .....................................................................................

A 80
A 81
A 82

Bio-Oil and microbial resistant Cables


BIOFLEX-500 -JZ,Bio-fuel resistant, abrasion resistant, recyclable environment friendly, bio-oil resistant1), meter marking ...............................................
BIOFLEX-500 -JZ-C,Bio-fuel resistant, abrasion resistant, recyclable environmentfriendly, bio-oilresistant1), Cu-screened, EMC-preferred type, meter marking
KOMPOFLEX JZ-500,halogen-free, microbes resistant, low adhesion, meter marking .....................................................................................
KOMPOFLEX JZ-500-C,halogen-free, microbes resistant, Cu-screende, EMC-preferred type, meter marking ........................................................

A 84
A 85

A 87
A 88

A4

JZ-500
JZ-500 COLD
JZ-500 orange
H05VV5-F (NYSLY-JZ)
(H)05VV5-F ((N)YSLY-JZ)
JZ-750
JZ-600
H03VV-F
H05VV-F
JB-500
JB-750
JB-750 yellow
F-CY-OZ (LiY-CY)
F-CY-JZ
H05VVC4V5-K (NYSLYCY-JZ)
(H)05VVC4V5-K (N)YSLYCY-JZ
Y-CY-JZ
SY-JZ
JZ-600-Y-CY
Y-CY-JB
SY-JB
Photo: KUKA

PVC Control Cables

A5

31472-00e-A005.indd 38

03.04.2009 7:39:41 Uhr

Masters: 10001 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

JZ-500

flexible, number coded, meter marking

Technical data

Cable structure

Properties

Control cables, special PVC


Requirements adapted to DIN VDE 0245,
0281, 0293, 0295
Temperature range
flexing -15C1) to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
Teil811-1-4, EN60811-1-4

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVC Z 7225
Black cores with continuous white
numbering according to DINVDE0293 (also
available with other core colours)
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lenght
Outer sheath of special PVC, TM2 to
DINVDE0281 part1 and HD21.1
colour grey (RAL7001)
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
Important for assemblers: We supply any
"desired length" of stranded cores without
outer sheath, core insulation colour acc.
RAL 9005 with number combination acc.
customers requirement.
Different dimensions are also available with
red resp. blue cores.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification
when ordering.
screened analogue type:
F-CY-JZ, seepageA27
F-CY-OZ (LiY-CY), seepageA25
Y-CY-JZ, seepageA32

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as measuring and control cables in tool machines, conveyor belts, production lines
in machinery production, in air-conditioning and in steel production.
The earth core is laid in the outer layer. Selected PVC-compounds guarantee a good flexibility as well as an economic and fast installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
10001
10002
10003
10004
10005
10006
10007
10008
10009
10010
10011
10172
10012
10013
10014
10015
10183
10016
10017
10018
10019
10020
10021
10022
10023
10024

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
6G0,5
7G0,5
7x0,5
8G0,5
8x0,5
10G0,5
12G0,5
12x0,5
14G0,5
16G0,5
18G0,5
20G0,5
21G0,5
25G0,5
30G0,5
32G0,5
34G0,5
40G0,5
42G0,5

Outer
app. mm
4,9
5,2
5,2
5,6
5,6
6,3
6,3
6,9
6,9
6,9
8,1
8,1
9,0
9,2
9,2
9,7
10,4
11,0
11,5
12,2
13,3
13,8
14,3
15,1
16,3
16,3

Cop.
weight
kg / km
9,6
14,4
14,4
19,0
19,0
24,0
24,0
29,0
33,6
33,6
38,0
38,0
48,0
58,0
58,0
67,0
76,0
86,0
96,0
101,0
120,0
144,0
154,0
163,0
192,0
202,0

Weight
app.
kg / km
40,0
46,0
46,0
56,0
56,0
65,0
65,0
75,0
80,0
80,0
97,0
97,0
116,0
135,0
135,0
150,0
175,0
196,0
215,0
240,0
270,0
310,0
323,0
362,0
434,0
449,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Part No.
10025
10169
10026
10027
10028
10029

10030
10031
10032
10033
10034
10035
10036
10037
10177
10038
10039
10040
10173
10041
10042
10043
10044
10045
10046

No.cores x
cross-sec.
mm
50G0,5
52G0,5
61G0,5
65G0,5
80G0,5
100G0,5

2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
6G0,75
6x0,75
7G0,75
7x0,75
8G0,75
8x0,75
9G0,75
10G0,75
12G0,75
12x0,75
14G0,75
15G0,75

Outer
app. mm
17,9
17,9
19,2
20,2
22,0
24,3

5,3
5,6
5,6
6,3
6,3
6,9
6,9
7,7
7,7
7,7
7,7
9,0
9,0
9,8
9,8
10,0
10,0
10,8
11,2

Cop.
weight
kg / km
240,0
252,0
293,0
312,0
384,0
480,0

14,4
21,6
21,6
28,8
29,0
36,0
36,0
43,0
43,0
50,0
50,0
58,0
58,0
65,0
72,0
86,0
86,0
101,0
108,0

Weight
app.
kg / km
513,0
534,0
625,0
682,0
780,0
980,0

46,0
54,0
54,0
66,0
66,0
80,0
80,0
99,0
99,0
110,0
110,0
130,0
130,0
153,0
162,0
179,0
179,0
214,0
218,0

AWG-No.
20
20
20
20
20
20

18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
Continuation

A6

Masters: 10001 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

JZ-500
Part No.
10047
10533
10048
10049
10050
10534
10051
10052
10182
10053
10054
10055
10056
10057
10178
10058
10059

10060
10061
10062
10063
10064
10065
10066
10067
10068
10069
10070
10071
10180
10170
10072
10073
10074
10075
10076
10174
10197
10077
10184
10179
10175
10078
10176
10196
10198
10168
10079
10080
10199
10081
10167
10082
10083
10084
10085
10086
10087
10088
10089

10090
10091
10092
10093
10094
10095
10096
10097
10098
10099
10100
10101
10181
10102
10103
10104
10105
10106
10107
10185
10108
10109

No.cores x
cross-sec.
mm
18G0,75
19G0,75
20G0,75
21G0,75
25G0,75
27G0,75
32G0,75
34G0,75
37G0,75
40G0,75
41G0,75
42G0,75
50G0,75
61G0,75
65G0,75
80G0,75
100G0,75

2x1
3G1
3x1
4G1
4x1
5G1
5x1
6G1
7G1
7x1
8G1
9G1
10G1
10x1
12G1
12x1
14G1
16G1
18G1
18x1
19G1
20G1
20x1
21G1
24G1
25G1
25x1
26G1
27G1
30x1
34G1
36G1
37G1
40G1
40x1
41G1
42G1
50G1
56G1
61G1
65G1
80G1
100G1

2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
6G1,5
7G1,5
7x1,5
8G1,5
9G1,5
10G1,5
11G1,5
12G1,5
12x1,5
14G1,5
16G1,5
18G1,5
19G1,5
20G1,5
21G1,5

flexible, number coded, meter marking


Outer
app. mm
12,2
12,7
12,7
13,5
14,5
15,2
16,1
16,7
17,2
18,0
18,0
18,0
19,8
21,2
22,5
24,3
27,0

5,6
6,1
6,1
6,6
6,6
7,5
7,5
8,1
8,1
8,1
9,6
10,6
10,6
10,6
10,8
10,8
11,4
12,3
12,9
12,9
13,0
13,7
13,7
14,4
14,7
15,6
15,6
15,6
15,8
16,4
17,9
17,9
18,4
19,4
19,4
19,4
19,4
21,2
22,1
22,7
24,2
26,2
29,2

6,4
6,8
6,8
7,6
7,6
8,3
8,3
9,2
9,2
9,2
10,6
12,0
12,0
12,2
12,2
12,2
13,0
13,9
14,8
15,2
15,5
16,4

Cop.
weight
kg / km
130,0
137,0
144,0
151,0
180,0
195,0
230,0
245,0
266,0
288,0
296,0
302,0
360,0
439,0
468,0
576,0
720,0

19,2
29,0
29,0
38,4
38,4
48,0
48,0
58,0
67,0
67,0
77,0
86,0
96,0
96,0
115,0
115,0
134,0
154,0
173,0
173,0
182,0
192,0
192,0
205,0
230,0
240,0
240,0
252,0
259,0
308,0
326,0
346,0
355,0
384,0
384,0
394,0
403,0
480,0
538,0
586,0
628,0
768,0
960,0

29,0
43,0
43,0
58,0
58,0
72,0
72,0
86,0
101,0
101,0
115,0
129,0
144,0
158,0
173,0
173,0
202,0
230,0
259,0
279,0
288,0
302,0

Weight
app.
kg / km
257,0
264,0
286,0
320,0
365,0
382,0
455,0
510,0
537,0
595,0
607,0
612,0
735,0
845,0
895,0
1070,0
1322,0

60,0
72,0
72,0
86,0
86,0
104,0
104,0
125,0
141,0
141,0
175,0
200,0
217,0
217,0
230,0
230,0
271,0
300,0
343,0
343,0
355,0
375,0
375,0
420,0
440,0
485,0
485,0
500,0
534,0
550,0
650,0
668,0
701,0
755,0
755,0
770,0
810,0
936,0
920,0
1100,0
1180,0
1294,0
1644,0

70,0
90,0
90,0
109,0
109,0
131,0
131,0
157,0
184,0
184,0
216,0
259,0
275,0
300,0
309,0
309,0
345,0
386,0
440,0
445,0
490,0
555,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A7

18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Part No.
10110
10535
10111
10112
10536
10113
10114
10115
10116
10117
10187
10118
10119

10120
10121
10122
10123
10124
10125
10126
10127
10128
10129
10130
10131
10132
10133
10134
10135
10136
10137
10138
10139

10140
10141
10142
10143
10144
10145
10146

10147
10148
10149
10150

10151
10152
10153
10154

10190
10155
10156
10157

10191
10158
10159
10160

10192
10161
10162

10193
10163
10188

10194
10164
10189

10195
10165
10333

10166

13139

13140

No.cores x
cross-sec.
mm
25G1,5
27G1,5
32G1,5
34G1,5
37G1,5
41G1,5
42G1,5
50G1,5
56G1,5
61G1,5
65G1,5
80G1,5
100G1,5

2x2,5
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
7G2,5
7x2,5
8G2,5
12G2,5
14G2,5
18G2,5
21G2,5
25G2,5
34G2,5
42G2,5
50G2,5
61G2,5
100G2,5

2x4
3G4
4G4
5G4
7G4
8G4
12G4

3G6
4G6
5G6
7G6

3G10
4G10
5G10
7G10

3G16
4G16
5G16
7G16

3G25
4G25
5G25
7G25

3x35
4G35
5G35

3G50
4G50
5G50

3G70
4G70
5G70

3G95
4G95
5G95

4G120

4G150

4G185

Outer
app. mm
17,8
19,0
19,5
20,2
20,2
22,0
22,0
24,2
25,1
25,8
27,4
29,8
33,0

7,8
8,3
8,3
9,2
9,2
10,1
10,1
11,2
11,2
13,4
15,1
16,2
18,2
20,2
22,1
25,2
27,2
30,0
32,2
41,2

9,2
9,7
10,8
12,1
13,4
13,4
18,3

11,9
13,0
14,7
16,2

15,1
16,7
18,6
20,7

18,0
20,0
22,4
24,8

22,2
24,7
27,6
30,5

25,4
28,0
31,3

31,4
34,7
38,7

38,5
42,7
47,6

43,2
47,9
52,7

52,6

62,3

67,0

Cop.
weight
kg / km
360,0
389,0
461,0
490,0
533,0
576,0
605,0
720,0
806,0
878,0
936,0
1152,0
1440,0

48,0
72,0
72,0
96,0
96,0
120,0
120,0
168,0
168,0
192,0
288,0
336,0
432,0
504,0
600,0
816,0
1008,0
1200,0
1464,0
2400,0

77,0
115,0
154,0
192,0
269,0
307,0
461,0

173,0
230,0
288,0
403,0

288,0
384,0
480,0
672,0

461,0
614,0
768,0
1075,0

720,0
960,0
1200,0
1680,0

1008,0
1344,0
1680,0

1440,0
1920,0
2400,0

2016,0
2688,0
3360,0

2736,0
3648,0
4560,0

4608,0

5760,0

7104,0

Weight
app.
kg / km
620,0
670,0
790,0
830,0
892,0
996,0
1007,0
1250,0
1332,0
1440,0
1602,0
1871,0
2353,0

112,0
148,0
148,0
178,0
178,0
221,0
221,0
306,0
306,0
363,0
498,0
569,0
764,0
914,0
1044,0
1470,0
1790,0
2095,0
2750,0
4450,0

195,0
230,0
295,0
361,0
458,0
590,0
790,0

355,0
424,0
525,0
625,0

540,0
701,0
858,0
1106,0

827,0
1035,0
1259,0
1780,0

1186,0
1582,0
1999,0
2825,0

1585,0
2105,0
2633,0

2550,0
2940,0
2936,0

3180,0
4090,0
5443,0

4680,0
5540,0
6931,0

7000,0

8340,0

9904,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16

14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

12
12
12
12
12
12
12

10
10
10
10

8
8
8
8

6
6
6
6

4
4
4
4

2
2
2

1
1
1

2/0
2/0
2/0

3/0
3/0
3/0

4/0

300 kcmil

350 kcmil

Masters: 10750 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

JZ-500 COLD

flexible at low temperature, number coded, meter marking

Technical data

Cable structure

Properties

Control cables, special PVC


Requirements adapted to DIN VDE 0245,
0281, 0293, 0295
Temperature range
flexing -30C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Core insulation of special PVC Z 7225
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lenght
Outer sheath of special PVC, TM2 to
DINVDE0281 part1 and HD21.1
colour black (RAL9005)
with meter marking

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).

Application
This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without
forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport
belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses.
Selected PVC mixtures guarantee good flexibility, efficient and fast installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
10750

10751
10752
10753
10754
10755
10756
10757
10758
10759
10760
10761

10762
10763
10764
10765
10766
10767
10768
10769
10770
10771
10772
10773

No.cores x
cross-sec.
mm
2x0,5

3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
12G0,75
18G0,75
25G0,75

2x1
3G1
3x1
4G1
4x1
5G1
5x1
7G1
7x1
12G1
18G1
25G1

Outer
app. mm
4,9

5,7
5,7
6,2
6,2
6,7
6,7
7,7
7,7
10,0
12,2
14,5

5,6
6,1
6,1
6,6
6,6
7,5
7,5
8,1
8,1
10,8
12,9
15,6

Cop.
weight
kg / km
9,6

21,6
21,6
28,8
29,0
36,0
36,0
50,0
50,0
86,0
130,0
180,0

19,2
29,0
29,0
38,4
38,4
48,0
48,0
67,0
67,0
115,0
173,0
240,0

Weight
app.
kg / km
40,0

54,0
54,0
66,0
66,0
80,0
80,0
110,0
110,0
179,0
257,0
365,0

60,0
72,0
72,0
86,0
86,0
104,0
104,0
141,0
141,0
230,0
343,0
485,0

AWG-No.
20

18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17
17
17

Part No.
10774
10775
10776
10777
10778
10779
10780
10781
10782
10783
10784
10785
10786

10787
10788
10789
10790
10791
10792
10793
10794
10795

10796
10797

No.cores x
cross-sec.
mm
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
6G1,5
7G1,5
7x1,5
12G1,5
18G1,5
25G1,5

2x2,5
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
7G2,5
7x2,5

4G6
5G6

Outer
app. mm
6,4
6,8
6,8
7,6
7,6
8,3
8,3
9,2
9,2
9,2
12,2
14,8
17,8

7,8
8,3
8,3
9,2
9,2
10,1
10,1
11,2
11,2

13,0
14,7

Cop.
weight
kg / km
29,0
43,0
43,0
58,0
58,0
72,0
72,0
86,0
101,0
101,0
173,0
259,0
360,0

48,0
72,0
72,0
96,0
96,0
120,0
120,0
168,0
168,0

230,0
288,0

Weight
app.
kg / km
70,0
90,0
90,0
109,0
109,0
131,0
131,0
157,0
184,0
184,0
309,0
440,0
620,0

112,0
148,0
148,0
178,0
178,0
221,0
221,0
306,0
306,0

424,0
525,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16

14
14
14
14
14
14
14
14
14

10
10

Dimensions and specifications may be changed without prior notice. (RA01)

A8

Masters: 10200 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

JZ-500

flexible, number coded, blue cores, meter marking

Technical data

Cable structure

Properties

Control cables, special PVC


Requirements adapted to DINVDE0245,
0281, 0293, 0295
Temperature range
flexing -15C1) to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
Teil811-1-4, EN60811-1-4

Bare copper, fine wire


conductors,according to DINVDE0295 cl.5,
BS6360 cl.5 and IEC60228 cl. 5
Core insulation of special PVC Z7225
Cores blue with continuous white
numbering according to DINVDE0293 (also
available with other core colours)
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lenght
Outer sheath of special PVC, TM2 to
DINVDE0281 part1 and HD21.1
Colour grey (RAL 7001)
with meter marking, change-over in 2009

Extensively oil resistant.


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
Important for assemblers: We supply any
"desired length" of stranded cores without
outer sheath, core insulation colour acc.
RAL 5010 with number combination acc.
customers requirement.

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as measuring and control cables in tool machines, conveyor belts, production lines
in machinery production, in air-conditioning and in steel production. The cores have been numbered in such a way that there is no difficulty
in recognising them, even if only a small piece of sheathing has been removed. The numbers have been underlined to avoid confusion. The
earth core is laid in the outer layer. Selected PVC-compounds guarantee a good flexibility as well as an economic and fast installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
10200
10201
10202
10203
10205
10206
10208
10209
10210
10211
10212
10213
10214
10215
10216
10220
10223

10224
10225
10226
10227
10229
10232
10233
10234
10236
10237
10238
10239
10240
10241

10249
10250
10251
10252

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
8G0,5
12G0,5
14G0,5
18G0,5
20G0,5
21G0,5
25G0,5
30G0,5
32G0,5
34G0,5
61G0,5
100G0,5

2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
18G0,75
20G0,75
21G0,75
25G0,75
32G0,75
34G0,75

2x1
3G1
4G1
5G1

Outer
app. mm
4,9
5,2
5,6
6,3
6,9
8,1
9,2
9,7
11,0
11,5
12,2
13,3
13,8
14,3
15,1
19,2
24,3

5,3
5,6
6,3
6,9
7,7
9,8
10,0
10,8
12,2
12,7
13,5
14,5
16,1
16,7

5,6
6,1
6,6
7,5

Cop.
weight
kg / km
9,6
14,4
19,0
24,0
33,6
38,0
58,0
67,0
86,0
96,0
96,0
120,0
144,0
154,0
163,0
293,0
480,0

14,4
21,6
29,0
36,0
50,0
72,0
86,0
101,0
130,0
144,0
151,0
180,0
230,0
245,0

19,2
29,0
38,4
48,0

Weight
app.
kg / km
40,0
46,0
56,0
65,0
80,0
97,0
135,0
150,0
196,0
215,0
240,0
270,0
310,0
323,0
362,0
625,0
980,0

46,0
54,0
66,0
80,0
110,0
162,0
179,0
214,0
257,0
286,0
320,0
365,0
455,0
510,0

60,0
72,0
86,0
104,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A9

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

18
18
18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17

Part No.
10332
10256
10258
10259
10260
10261
10262
10265

10273
10274
10275
10276
10278
10279
10282
10283
10284
10285
10286
10288

10298
10299
10300
10301
10302

10315
10316
10317

10321
10322
10323
10324

No.cores x
cross-sec.
mm
7G1
12G1
16G1
18G1
20G1
25G1
34G1
41G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
12G1,5
14G1,5
16G1,5
18G1,5
20G1,5
25G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5

3G4
4G4
5G4

3G6
4G6
5G6
7G6

Outer
app. mm
8,1
10,8
12,3
12,9
13,7
15,6
17,9
19,4

6,4
6,8
7,6
8,3
9,2
10,6
12,2
13,0
13,9
14,8
15,5
17,8

7,8
8,3
9,2
10,1
11,2

9,7
10,8
12,1

11,9
13,0
14,7
16,2

Cop.
weight
kg / km
67,0
115,0
154,0
173,0
192,0
240,0
326,0
394,0

29,0
43,0
58,0
72,0
101,0
115,0
173,0
202,0
230,0
259,0
288,0
360,0

48,0
72,0
96,0
120,0
168,0

115,0
154,0
192,0

173,0
230,0
288,0
403,0

Weight
app.
kg / km
141,0
230,0
300,0
343,0
375,0
485,0
650,0
770,0

70,0
90,0
109,0
131,0
184,0
216,0
309,0
345,0
386,0
440,0
490,0
620,0

112,0
148,0
178,0
221,0
306,0

230,0
295,0
361,0

355,0
424,0
525,0
625,0

AWG-No.
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16

14
14
14
14
14

12
12
12

10
10
10
10

Masters: 10400 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

JZ-500

flexible, number coded, red cores, meter marking

Technical data

Cable structure

Properties

Control cables, special PVC


Requirements adapted to DINVDE0245,
0281, 0293, 0295
Temperature range
flexing -15C1) to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
Teil811-1-4, EN60811-1-4

Bare copper, fine wire


conductors,according to DINVDE0295 cl.5,
BS6360 cl.5 and IEC60228 cl.5
Core insulation of special PVC Z7225
Red cores with continuous white
numbering according to DINVDE0293 (also
available with other core colours)
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lenght
Outer sheath of special PVC, TM2 to
DINVDE0281 part1 and HD21.1
Colour grey (RAL 7001)
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
Important for assemblers: We supply any
"desired length" of stranded cores without
outer sheath, core insulation colour acc.
RAL 3000 with number combination acc.
customers requirement.

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as measuring and control cables in tool machines, conveyor belts, production lines
in machinery production, in air-conditioning and in steel production. The cores have been numbered in such a way that there is no difficulty
in recognising them, even if only a small piece of sheathing has been removed. The numbers have been underlined to avoid confusion. The
earth core is laid in the outer layer. Selected PVC-compounds guarantee a good flexibility as well as an economic and fast installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
10400
10401
10402
10403
10405
10407
10408
10409
10410
10411
10412
10413
10414
10415
10416

10424
10425
10426
10427
10429
10431
10432
10433
10434
10436
10437
10438
10439
10440

10449
10450
10451
10452
10454
10457

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
20G0,5
21G0,5
25G0,5
30G0,5
32G0,5
34G0,5

2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
9G0,75
10G0,75
12G0,75
14G0,75
18G0,75
20G0,75
21G0,75
25G0,75
32G0,75

2x1
3G1
4G1
5G1
7G1
12G1

Outer
app. mm
4,9
5,2
5,6
6,3
6,9
9,0
9,2
9,7
11,0
11,5
12,2
13,3
13,8
14,3
15,1

5,3
5,6
6,3
6,9
7,7
9,8
9,8
10,0
10,8
12,2
12,7
13,5
14,5
16,1

5,6
6,1
6,6
7,5
8,1
10,8

Cop.
weight
kg / km
9,6
14,4
19,0
24,0
33,6
48,0
58,0
67,0
86,0
96,0
96,0
120,0
144,0
154,0
163,0

14,4
21,6
29,0
36,0
50,0
65,0
72,0
86,0
101,0
130,0
144,0
151,0
180,0
230,0

19,2
29,0
38,4
48,0
67,0
115,0

Weight
app.
kg / km
40,0
46,0
56,0
65,0
80,0
116,0
135,0
150,0
196,0
215,0
240,0
270,0
310,0
323,0
362,0

46,0
54,0
66,0
80,0
110,0
153,0
162,0
179,0
214,0
257,0
286,0
320,0
365,0
455,0

60,0
72,0
86,0
104,0
141,0
230,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

18
18
18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17

Part No.
10459
10460
10461
10462
10463
10466

10474
10475
10476
10477
10479
10480
10481
10483
10484
10485
10486
10487
10489
10490
10491
10493

10499
10500
10501
10502
10503
10504
10505

10515
10516
10517
10518

No.cores x
cross-sec.
mm
16G1
18G1
20G1
25G1
34G1
41G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
9G1,5
12G1,5
14G1,5
16G1,5
18G1,5
20G1,5
25G1,5
32G1,5
34G1,5
42G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
12G2,5

2x4
3G4
4G4
5G4

Outer
app. mm
12,3
12,9
13,7
15,6
17,9
19,4

6,4
6,8
7,6
8,3
9,2
10,6
12,0
12,2
13,0
13,9
14,8
15,5
17,8
19,5
20,2
22,0

7,8
8,3
9,2
10,1
11,2
13,4
15,1

9,2
9,7
10,8
12,1

Cop.
weight
kg / km
154,0
173,0
192,0
240,0
326,0
394,0

29,0
43,0
58,0
72,0
101,0
115,0
130,0
173,0
202,0
230,0
259,0
288,0
360,0
461,0
490,0
605,0

48,0
72,0
96,0
120,0
168,0
192,0
288,0

77,0
115,0
154,0
192,0

Weight
app.
kg / km
300,0
343,0
375,0
485,0
650,0
770,0

70,0
90,0
109,0
131,0
184,0
216,0
259,0
309,0
345,0
386,0
440,0
490,0
620,0
790,0
830,0
1007,0

112,0
148,0
178,0
221,0
306,0
363,0
498,0

195,0
230,0
295,0
361,0

AWG-No.
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

14
14
14
14
14
14
14

12
12
12
12

Dimensions and specifications may be changed without prior notice. (RA01)

A 10

Masters: 10537 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

JZ-500 orange

flexible, orange cores, control cable for interlocking

purposes, meter marking

Technical data

Cable structure

Properties

Special PVC control cable for interlocking


purposes
Requirements adapted to DINVDE 0245,
0281, 0293, 0295
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of special PVC Z7225
Cores orange with continuous black
numbering according to DINVDE0293
JZ-version with green-yellow earth core: 3
cores and above
OZ-version without green-yellow earth core
Special PVC outer sheath TM2, to
DINVDE0281 part1 and HD21.1
Colour orange (RAL 2003)
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as control cable according EN60204 part1 and VDE0113 part1.
As per recommendation of the specified standards the insulated conductors of control current circuits should be coloured orange, when
they are used for interlocking purposes. These control circuits are supplied with an external power and remain active under current when
the main switch is disconnected or switched off.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
10537
10539
10538
10541
10540
10542

10544
10545
10546
10547

No.cores x
cross-sec.
mm
2x1
3x1
3G1
4x1
4G1
5G1

2x1,5
3G1,5
4G1,5
5G1,5

Outer
app. mm
5,6
6,1
6,1
6,6
6,6
7,5

6,4
6,8
7,6
8,3

Cop.
weight
kg / km
19,2
29,0
29,0
38,4
38,4
48,0

29,0
43,0
58,0
72,0

Weight
app.
kg / km
60,0
72,0
72,0
86,0
86,0
104,0

70,0
90,0
109,0
131,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 11

17
17
17
17
17
17

16
16
16
16

Part No.
10747
10748
10749

No.cores x
cross-sec.
mm
3G2,5
4G2,5
5G2,5

Outer
app. mm
8,3
9,2
10,1

Cop.
weight
kg / km
72,0
96,0
120,0

Weight
app.
kg / km
148,0
178,0
221,0

AWG-No.
14
14
14

Masters: 13122 - ProductGroupID: PG1504 - Layout: L101_1 - Umbruch:

H05VV5-F (NYSLY-JZ)

flexible, number coded,

oil resistant, meter marking

Technical data

Cable structure

Properties

Control cable, special PVC with oil resistant


outer jacket to DINVDE0281 part13,
HD21.13S1 and IEC60227/75
Temperature range
flexing -5C to +70C
fixed installation -40C to +70C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V, 5 min.
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire stranded conductor


to DINVDE0295 cl.5, BS6360 cl.5, HD383
and IEC60228 cl.5
Special PVC core insulation TI2 to
DINVDE0281 part1
Black cores with white figure imprint to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC outer jacket, TM5 to
DINVDE0281 part1, HD21.1.S4/A16
Colour grey (RAL 7001)
with meter marking, change-over in 2009

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Oil resistant toHD/EN60811-2-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
H05VVC4V5-K (NYSLYCY-JZ),
seepageA29

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries,
conveyor belts and production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling
plants and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
13122
13001
13002
13003
13004
13005
13920
13006
13921
13007
13922
13008
13009
13923
13010
13924
13125
13011
13012
13925

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
6G0,5
7G0,5
8G0,5
9G0,5
10G0,5
12G0,5
14G0,5
18G0,5
25G0,5
27G0,5
34G0,5
36G0,5
41G0,5
50G0,5
61G0,5
65G0,5

Outer
app. mm
5,9
6,2
6,7
7,4
8,4
9,1
9,6
10,6
10,8
11,2
11,7
13,0
16,0
16,1
17,7
17,7
19,8
21,5
23,0
25,3

Cop.
weight
kg / km
9,7
14,4
19,0
24,0
29,0
33,6
38,0
43,0
48,0
58,0
67,0
86,0
120,0
129,6
163,0
172,0
196,0
240,0
293,0
312,0

Weight
app.
kg / km
46,0
54,0
65,0
80,0
104,0
119,0
134,0
136,0
166,0
186,0
215,0
251,0
349,0
373,0
480,0
510,0
570,0
658,0
780,0
810,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Part No.
13123
13013
13014
13015
13016
13017
13926
13018
13019
13927
13020
13021
13928
13022
13929
13126
13023
13024
13930

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
8G0,75
9G0,75
12G0,75
14G0,75
18G0,75
25G0,75
27G0,75
34G0,75
36G0,75
41G0,75
50G0,75
61G0,75
65G0,75

Outer
app. mm
6,3
6,7
7,3
8,3
9,0
9,7
10,4
11,5
12,1
12,4
14,0
17,0
17,1
19,1
19,1
21,3
23,2
25,8
27,1

Cop.
weight
kg / km
14,1
21,6
29,0
36,0
43,0
50,0
58,0
65,0
86,0
101,0
130,0
180,0
195,0
245,0
259,0
295,0
360,0
439,0
468,0

Weight
app.
kg / km
52,0
68,0
82,0
107,0
132,0
145,0
189,0
194,0
231,0
274,0
313,0
461,0
493,0
614,0
646,0
730,0
896,0
1030,0
1071,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
Continuation

A 12

Masters: 13122 - ProductGroupID: PG1504 - Layout: L101_1 - Umbruch:

H05VV5-F (NYSLY-JZ)

flexible, number coded,

oil resistant, meter marking


Part No.
13119
13025
13026
13027
13028
13029
13931
13030
13031
13932
13032
13933
13033
13934
13034
13124
13935
13127
13035
13036
13936

13120
13037
13038
13039
13040
13041
13937
13042
13043
13121
13044
13938
13045
13939
13046
13047
13940
13941
13128
13048
13049
13942

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
6G1
7G1
8G1
9G1
12G1
14G1
18G1
19G1
25G1
27G1
34G1
36G1
37G1
41G1
50G1
61G1
65G1

2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
9G1,5
12G1,5
14G1,5
18G1,5
19G1,5
25G1,5
27G1,5
32G1,5
34G1,5
36G1,5
37G1,5
41G1,5
50G1,5
61G1,5
65G1,5

Outer
app. mm
6,6
7,0
7,6
8,7
9,5
10,2
11,0
12,1
12,7
13,3
15,0
15,0
18,0
18,0
20,6
21,0
21,0
22,5
24,5
26,0
28,1

7,3
7,9
8,7
9,6
10,7
11,8
13,2
13,5
14,4
15,3
17,2
17,2
21,7
21,7
22,4
24,1
24,4
24,4
26,3
28,9
30,8
32,2

Cop.
weight
kg / km
19,0
29,0
38,0
48,0
58,0
67,0
77,0
86,0
115,0
134,0
173,0
183,0
240,0
259,0
326,0
348,0
355,0
392,0
480,0
586,0
624,0

29,0
43,0
58,0
72,0
86,0
101,0
115,0
130,0
173,0
202,0
259,0
274,0
360,0
389,0
461,0
490,0
518,0
532,0
590,0
720,0
878,0
963,0

Weight
app.
kg / km
66,0
78,0
104,0
123,0
152,0
183,0
220,0
230,0
269,0
361,0
400,0
413,0
546,0
582,0
724,0
775,0
785,0
822,0
1052,0
1265,0
1315,0

77,0
97,0
128,0
149,0
196,0
216,0
271,0
282,0
324,0
372,0
485,0
495,0
671,0
695,0
820,0
881,0
905,0
920,0
1085,0
1381,0
1640,0
1730,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 13

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Part No.
13943
13050
13051
13052
13053
13945
13054
13946
13055
13056
13947
13057
13948
13949
13058
13059

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
12G2,5
14G2,5
18G2,5
25G2,5
27G2,5
34G2,5
36G2,5
41G2,5
50G2,5
61G2,5

Outer
app. mm
9,1
9,6
10,8
11,6
14,2
16,1
17,7
19,0
21,4
26,1
26,2
29,5
29,6
32,0
35,0
37,1

Cop.
weight
kg / km
48,0
72,0
96,0
120,0
168,0
192,0
288,0
336,0
432,0
600,0
648,0
816,0
864,0
984,0
1200,0
1464,0

Weight
app.
kg / km
110,0
154,0
212,0
242,0
350,0
379,0
543,0
611,0
787,0
1175,0
1280,0
1529,0
1791,0
1905,0
2290,0
2724,0

AWG-No.
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

Masters: 13133 - ProductGroupID: PG1504 - Layout: L100_1 - Umbruch:

(H)05VV5-F ((N)YSLY-JZ)

flexible, number coded, oil

resistant, meter marking

Technical data

Cable structure

Properties

Control cable, special PVC with oil resistant


outer jacket adapted to VDE0281 part13,
HD21.13S1 and IEC60227/75 deviation of
conductor cross sections.
Temperature range
flexing -5C to +70C
fixed installation -40C to +70C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V, 5 min
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire stranded conductor


to DINVDE0295 cl.5, BS6360 cl.5,
IEC60228 cl.5 and HD383
Special PVC core insulation TI2 to
DINVDE0281 part1
Black cores with white figure imprint to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC outer jacket, TM5 to
DINVDE0281 part1, HD21.1.S4/A16
Colour grey (RAL7001)
with meter marking, change-over in 2009

PVC self-extinguishing and flame retardant


according to DINVDE0482 part265-2-1/
EN50265-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Oil resistant toHD/EN60811-2-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
(H)05VVC4V5-K, seepageA31

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries,
conveyor belts and production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling
plants and car washing stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
13133
13134
13135
13136
13138
13141

13142
13143
13144
13145
13146

13148
13149
13150
13151

No.cores x
cross-sec.
mm
2x4
3G4
4G4
5G4
7G4
12G4

2x6
3G6
4G6
5G6
7G6

3G10
4G10
5G10
7G10

Outer
app. mm
10,7
11,3
12,4
13,9
16,5
20,8

12,0
12,9
14,2
15,9
18,9

16,3
18,1
20,3
24,3

Cop.
weight
kg / km
77,0
115,0
154,0
192,0
269,0
461,0

116,0
173,0
230,0
288,0
403,0

288,0
384,0
480,0
672,0

Weight
app.
kg / km
195,0
230,0
295,0
361,0
466,0
810,0

280,0
358,0
424,0
525,0
625,0

540,0
701,0
858,0
1106,0

AWG-No.
12
12
12
12
12
12

10
10
10
10
10

8
8
8
8

Part No.
13153
13154
13155
13156

13159
13160

13161
13162
13163

13164
13165
13166

No.cores x
cross-sec.
mm
3G16
4G16
5G16
7G16

4G25
5G25

3G35
4G35
5G35

3G50
4G50
5G50

Outer
app. mm
18,3
20,9
23,4
28,5

26,3
29,5

26,0
28,7
31,4

29,8
33,4
37,3

Cop.
weight
kg / km
461,0
614,0
768,0
1075,0

960,0
1200,0

1008,0
1344,0
1680,0

1440,0
1920,0
2400,0

Weight
app.
kg / km
827,0
1035,0
1259,0
1780,0

1582,0
1852,0

1614,0
2110,0
2652,0

2560,0
2972,0
3948,0

AWG-No.
6
6
6
6

4
4

2
2
2

1
1
1

Dimensions and specifications may be changed without prior notice. (RA01)

A 14

Masters: 10800 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

JZ-750

flexible, number coded, 750V, meter marking

Technical data

Cable structure

Properties

Special PVC control cables


Requirements adapted to DINVDE0281
part13 and IEC60227/7
identical with H05VV-F to VDE0281 part13
and IEC60227/7 type227 IEC75, but
without increased oil resistant outer sheath
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 450/750 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Black cores with white figure imprints to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC, outer sheath TM2, to
DINVDE0281 part1
colour grey (RAL 7001)
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, wherever internationally recognized PVC cables are required. E.g. as a control or
measurements cable on industrial machinery, on conveyor systems or in industrial plants, etc. The number coding has been brought onto
the cores in such a way that it is easily identifiable and the core numbers are individually underlined to avoid confusion. The green-yellow
earth core is laid in the outer layer.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
10800
10801
10802
10803
10804
10805
10806
10807
10808
10809
10810
10811
10812
10813
10814
10815
10816

10817
10818
10819
10820
10821
10822
10823
10824
10825
10826
10827
10828
10829
10830
10831
10832

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
8G0,5
10G0,5
12G0,5
14G0,5
16G0,5
18G0,5
21G0,5
25G0,5
30G0,5
40G0,5
50G0,5
61G0,5

2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
8G0,75
10G0,75
12G0,75
15G0,75
18G0,75
21G0,75
25G0,75
34G0,75
41G0,75
50G0,75
61G0,75

Outer
app. mm
5,6
5,9
6,7
7,3
8,8
9,6
10,6
11,1
11,7
12,3
12,9
14,5
15,8
16,6
19,5
21,3
22,6

6,1
6,5
7,1
7,9
9,5
10,2
11,4
11,6
13,1
13,9
15,5
17,0
19,3
20,9
23,0
24,8

Cop.
weight
kg / km
9,6
14,5
20,0
24,0
34,0
38,0
48,0
58,0
67,0
76,0
87,0
96,0
118,0
144,0
192,0
240,0
293,0

15,0
22,0
29,0
36,0
51,0
58,0
72,0
87,0
108,0
130,0
151,0
180,0
245,0
296,0
360,0
440,0

Weight
app.
kg / km
48,0
65,0
81,0
98,0
123,0
155,0
180,0
208,0
248,0
260,0
285,0
375,0
400,0
475,0
590,0
710,0
880,0

60,0
78,0
104,0
116,0
148,0
160,0
195,0
248,0
295,0
346,0
395,0
505,0
684,0
780,0
940,0
1125,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 15

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Part No.

10833
10834
10835
10836
10837
10838
10839
10840
10841
10842
10843
10844
10845
10846
10847
10848
10849
10850
10851

10852
10853
10854
10855
10856
10857
10858
10859
10860
10861
10862
10863
10864

No.cores x
cross-sec.
mm

2x1
3G1
3x1
4G1
4x1
5G1
7G1
7x1
8G1
12G1
14G1
16G1
18G1
21G1
25G1
34G1
41G1
50G1
61G1

2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
7G1,5
8G1,5
9G1,5
12G1,5
14G1,5
16G1,5
18G1,5

Outer
app. mm

6,4
6,8
6,8
7,5
7,5
8,4
10,0
10,0
10,8
12,5
13,1
14,0
14,7
16,6
18,1
20,3
22,2
24,5
26,3

7,4
8,0
8,0
8,7
8,7
9,8
11,9
12,8
13,6
14,5
15,5
16,5
17,4

Cop.
weight
kg / km


20,0
29,0
29,0
39,0
39,0
48,0
68,0
68,0
77,0
116,0
134,0
154,0
173,0
205,0
240,0
326,0
394,0
480,0
586,0

29,0
43,0
43,0
58,0
58,0
72,0
101,0
115,0
130,0
173,0
202,0
230,0
259,0

Weight
app.
kg / km


80,0
92,0
92,0
122,0
122,0
137,0
186,0
186,0
240,0
293,0
340,0
400,0
437,0
505,0
606,0
770,0
880,0
1400,0
1450,0

90,0
120,0
120,0
150,0
155,0
177,0
220,0
248,0
278,0
364,0
390,0
490,0
550,0

AWG-No.

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16
Continuation

Masters: 10800 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

JZ-750
Part No.
10865
10866
10867
10868
10869
10870
10871

No.cores x
cross-sec.
mm
21G1,5
25G1,5
32G1,5
34G1,5
42G1,5
50G1,5
61G1,5

flexible, number coded, 750V, meter marking


Outer
app. mm
19,7
21,3
23,1
24,0
26,2
28,8
30,6

Cop.
weight
kg / km
302,0
360,0
461,0
490,0
605,0
720,0
878,0

Weight
app.
kg / km
670,0
745,0
810,0
1010,0
1115,0
1430,0
1750,0

AWG-No.
16
16
16
16
16
16
16

Part No.
10872
10873
10874
10875
10876
10877
10878
10879
10880

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
14G2,5
18G2,5
25G2,5

Outer
app. mm
9,1
9,9
11,0
12,0
14,6
18,1
19,4
21,7
26,5

Cop.
weight
kg / km
48,0
72,0
96,0
120,0
168,0
288,0
336,0
432,0
600,0

Weight
app.
kg / km
110,0
190,0
240,0
270,0
350,0
600,0
870,0
1050,0
1170,0

AWG-No.
14
14
14
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RA01)

A 16

Masters: 10550 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

JZ-600

flexible, number coded, 0,6/1kV, meter marking

Technical data

Cable structure

Properties

Special PVC control cables Adapted to


DINVDE0262/12.95 and DINVDE0281
part13, with insulation thickness for 1kV
type
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Power ratingas
per DIN VDE 0298
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,as per


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Black cores with white figure imprints to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM2, to
DINVDE0281 part1
colour black (RAL 9005)
with meter marking, change-over in 2009

Extensively oil resistant, chemical resistance


- see table Technical Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Resistant to ultra violet rays

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
Different dimensions are also available with
red resp. blue cores.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-600-Y-CY, seepageA36

Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air
conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with
free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable
to be used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable,
even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located
in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and
Arabian countries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
10550
10551
10552
10553
10554
10555
10556
10557
10558
10559
10560
10561
10562
10563
10564
10565
10566
10567
10568
10569
10570
10571
10572
10573
10574
10575
10576
10577
10578
10579
10580
10581

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
6G0,5
7G0,5
7x0,5
8G0,5
8x0,5
10G0,5
12G0,5
12x0,5
14G0,5
16G0,5
18G0,5
20G0,5
21G0,5
25G0,5
30G0,5
32G0,5
34G0,5
40G0,5
42G0,5
50G0,5
52G0,5
61G0,5
65G0,5
80G0,5
100G0,5

Outer
app. mm
6,3
6,7
6,7
7,2
7,2
8,0
8,0
8,9
8,9
8,9
10,2
10,2
11,2
11,4
11,4
12,3
12,9
13,8
14,4
14,4
16,4
17,2
18,0
18,7
20,2
20,2
22,1
22,1
23,6
25,0
27,2
30,2

Cop.
weight
kg / km
9,6
14,4
14,4
19,0
19,0
24,0
24,0
29,0
33,6
33,6
38,0
38,0
48,0
58,0
58,0
67,0
76,0
86,0
96,0
96,0
120,0
144,0
154,0
163,0
192,0
202,0
240,0
252,0
293,0
312,0
384,0
480,0

Weight
app.
kg / km
56,0
68,0
68,0
100,0
100,0
117,0
117,0
126,0
138,0
138,0
150,0
150,0
176,0
200,0
200,0
230,0
250,0
276,0
293,0
305,0
335,0
348,0
355,0
520,0
590,0
595,0
715,0
740,0
840,0
880,0
960,0
1050,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 17

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Part No.
10582
10583
10584
10585
10586
10587
10588
10589
10590
10591
10592
10593
10594
10595
10596
10597
10598
10599
10600
10601
10602
10603
10604
10605
10606
10607
10608
10609
10610
10611
10612
10613
10614
10615

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
6G0,75
6x0,75
7G0,75
7x0,75
8G0,75
8x0,75
9G0,75
10G0,75
12G0,75
12x0,75
14G0,75
15G0,75
18G0,75
20G0,75
21G0,75
25G0,75
32G0,75
34G0,75
37G0,75
40G0,75
41G0,75
42G0,75
50G0,75
61G0,75
65G0,75
80G0,75
100G0,75

Outer
app. mm
6,6
7,0
7,0
7,6
7,6
8,4
8,4
9,3
9,3
9,3
9,3
10,9
10,9
11,8
11,8
12,3
12,3
12,9
13,8
14,5
15,4
16,1
17,4
19,1
19,9
19,9
21,5
21,5
21,5
23,5
25,3
26,9
28,9
32,1

Cop.
weight
kg / km
14,4
21,6
21,6
29,0
29,0
36,0
36,0
43,0
43,0
50,0
50,0
58,0
58,0
65,0
72,0
86,0
86,0
101,0
108,0
130,0
144,0
151,0
180,0
230,0
245,0
260,0
288,0
296,0
302,0
360,0
439,0
468,0
576,0
720,0

Weight
app.
kg / km
66,0
74,0
74,0
126,0
126,0
140,0
140,0
170,0
170,0
190,0
190,0
212,0
212,0
227,0
238,0
257,0
257,0
286,0
319,0
362,0
394,0
422,0
486,0
595,0
638,0
696,0
726,0
750,0
770,0
895,0
1070,0
1110,0
1500,0
1889,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
Continuation

Masters: 10550 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

JZ-600
Part No.
10616
10617
10618
10619
10620
10621
10622
10623
10624
10625
10626
10627
10628
10629
10630
10631
10632
10633
10634
10635
10636
10637
10638
10639
10640
10641
10642
10643
10644
10645
10646
10647
10648
10649
10650
10651
10652
10653
10654
10655

10656
10657
10658
10659
10660
10661
10662
10663
10664
10665
10666
10667
10668
10669
10670
10671
10672
10673
10674
10675
10676
10677
10678
10679
10680
10681
10682
10683
10684
10685
10686
10687
10688

No.cores x
cross-sec.
mm
2x1
3G1
3x1
4G1
4x1
5G1
5x1
6G1
7G1
7x1
8G1
9G1
10G1
10x1
12G1
12x1
14G1
16G1
18G1
18x1
20G1
20G1
21G1
24G1
25G1
25x1
26G1
30x1
34G1
36G1
40G1
40x1
41G1
42G1
50G1
56G1
61G1
65G1
80G1
100G1

2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
6G1,5
7G1,5
7x1,5
8G1,5
9G1,5
10G1,5
11G1,5
12G1,5
12x1,5
14G1,5
16G1,5
18G1,5
19G1,5
20G1,5
21G1,5
25G1,5
32G1,5
34G1,5
40G1,5
42G1,5
50G1,5
56G1,5
61G1,5
65G1,5
80G1,5
100G1,5

flexible, number coded, 0,6/1kV, meter marking


Outer
app. mm
7,0
7,3
7,3
8,2
8,2
9,2
9,2
9,9
9,9
9,9
11,6
12,8
12,8
12,8
13,0
13,0
14,0
14,8
15,7
15,7
16,7
16,7
17,4
18,4
18,8
18,8
18,8
19,9
21,5
21,5
23,2
23,2
23,2
23,2
25,6
26,4
27,3
29,0
31,4
34,8

8,2
8,6
8,6
9,6
9,6
10,7
10,7
11,6
11,6
11,6
13,8
15,2
15,2
15,5
15,5
15,5
16,6
17,5
18,6
18,6
19,7
20,6
22,5
24,5
25,6
27,6
27,6
30,4
31,5
32,6
34,8
37,4
41,6

Cop.
weight
kg / km
19,2
29,0
29,0
38,4
38,4
48,0
48,0
58,0
67,0
67,0
77,0
86,0
96,0
96,0
115,0
115,0
134,0
154,0
173,0
173,0
192,0
192,0
205,0
236,0
240,0
240,0
252,0
308,0
326,0
346,0
384,0
384,0
394,0
403,0
480,0
538,0
586,0
628,0
786,0
960,0

29,0
43,0
43,0
58,0
58,0
72,0
72,0
86,0
101,0
101,0
115,0
130,0
144,0
158,0
173,0
173,0
202,0
230,0
259,0
279,0
288,0
302,0
360,0
461,0
490,0
576,0
605,0
720,0
806,0
878,0
936,0
1152,0
1440,0

Weight
app.
kg / km
80,0
96,0
96,0
100,0
100,0
130,0
130,0
150,0
170,0
170,0
230,0
250,0
270,0
270,0
290,0
290,0
320,0
360,0
405,0
405,0
450,0
480,0
510,0
550,0
570,0
570,0
590,0
650,0
750,0
790,0
850,0
850,0
890,0
900,0
1100,0
1190,0
1266,0
1560,0
1810,0
1950,0

95,0
112,0
112,0
139,0
139,0
170,0
170,0
190,0
225,0
225,0
250,0
280,0
300,0
330,0
370,0
370,0
400,0
450,0
520,0
550,0
600,0
600,0
730,0
880,0
950,0
990,0
1120,0
1400,0
1530,0
1700,0
1900,0
2300,0
2700,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Part No.

10689
10690
10691
10692
10693
10694
10695
10696
10697
10698
10699
10700
10701
10702
10703
10704
10705
10706
10707
10708

10709
10710
10711
10712
10713
10714
10715

10716
10717
10718
10719

10720
10721
10722
10723

10724
10725
10726
10727

10728
10729
10730
10731

10732
10733
10734

10735
10736
10742

10737
10738
10743

10739
10740
10744

10741

10745

10746

No.cores x
cross-sec.
mm

2x2,5
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
7G2,5
7x2,5
8G2,5
12G2,5
14G2,5
18G2,5
21G2,5
25G2,5
34G2,5
42G2,5
50G2,5
61G2,5
100G2,5

2x4
3G4
4G4
5G4
7G4
8G4
12G4

3G6
4G6
5G6
7G6

3G10
4G10
5G10
7G10

3G16
4G16
5G16
7G16

3G25
4G25
5G25
7G25

3G35
4G35
5G35

3G50
4G50
5G50

3G70
4G70
5G70

3G95
4G95
5G95

4G120

4G150

4G185

Outer
app. mm

9,4
10,1
10,1
11,2
11,2
12,5
12,5
13,8
13,8
16,1
18,3
19,4
22,0
25,0
26,7
30,4
33,0
36,2
38,8
49,5

11,4
12,3
13,7
15,2
16,7
19,9
22,6

14,0
15,5
17,3
19,2

16,4
18,2
20,4
22,4

20,5
22,6
25,4
27,8

24,8
27,6
30,3
33,6

27,5
30,5
34,1

33,5
37,2
41,8

38,7
42,7
47,6

43,3
48,0
52,8

52,6

61,3

67,1

Cop.
weight
kg / km


48,0
72,0
72,0
96,0
96,0
120,0
120,0
168,0
168,0
192,0
288,0
336,0
432,0
504,0
600,0
816,0
1008,0
1200,0
1464,0
2400,0

77,0
115,0
154,0
192,0
269,0
307,0
461,0

173,0
230,0
288,0
403,0

288,0
384,0
480,0
672,0

461,0
614,0
768,0
1075,0

720,0
960,0
1200,0
1680,0

1008,0
1344,0
1680,0

1440,0
1920,0
2400,0

2016,0
2688,0
3360,0

2736,0
3648,0
4560,0

4608,0

5760,0

7104,0

Weight
app.
kg / km


160,0
175,0
175,0
203,0
203,0
251,0
251,0
330,0
330,0
400,0
553,0
630,0
795,0
930,0
1110,0
1450,0
1750,0
2100,0
2540,0
3850,0

180,0
230,0
310,0
410,0
540,0
710,0
860,0

370,0
430,0
650,0
860,0

660,0
790,0
960,0
1300,0

700,0
1100,0
1600,0
1890,0

1450,0
1600,0
2050,0
2900,0

1900,0
2400,0
2900,0

2700,0
3400,0
4361,0

3300,0
4400,0
5807,0

5050,0
6010,0
7752,0

7500,0

8640,0

10380,0

AWG-No.

14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

12
12
12
12
12
12
12

10
10
10
10

8
8
8
8

6
6
6
6

4
4
4
4

2
2
2

1
1
1

2/0
2/0
2/0

3/0
3/0
3/0

4/0

300 kcmil

350 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

A 18

Masters: 29736 - ProductGroupID: PG2603 - Layout: L109_1 - Umbruch:

H03VV-F

according to DIN VDE 0281

Technical data

Cable structure

Properties

PVC-control cables to DINVDE0281 part5


and IEC60227-5, HD21.5 S3
Temperature range
flexing -5C to +70C
fixed installation -40C to +70C
Nominal voltage U0/U 300/300 V
Max. permissible operating voltage
in three-phase and one-phase
a.c. system U0/U 330/330 V
in direct current system
U0/U 495/495 V
Test voltage 2000 V
Breakdown voltage
min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5, IEC60228 cl.5 and HD383
PVC core insulation TI2 to
DINVDE0281part1
Cores colour coded to DINVDE0293-308
6 and more cores number coded
1x green-yellow earth core incl.
Green-yellow earth-core, 3 cores and above
Cores stranded in layers with optimal
lay-length
PVC outer jacket in black, white or as per
requirement
PVC outer jacket TM2 to DINVDE0281
part1

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
5 core and above in adaption (H).
The above list contains a selection of the
types we carry es stock.
Other sizes available on request.

Application
These cable types are especially suited to use on small appliances with low mechanical stress and for connection for light household appliances,
e.g. kitchen utensils, desk lamps, floor lamps, vacuum cleaners, office machines, radios, etc., as far as this cable is admitted to the relevant
specifications of the equipment.
These cables are not permitted to use with cooking or heating apparatus.
Cables with cross-section 0,75 mm are not suitable for outdoor use or use of industrial or farmer machineries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No. No.cores x
cross-sec.
mm
29736
2x0,5
29737
2x0,5
29738
2x0,5
29739
3G0,5
29740
3G0,5
29741
3G0,5
29742
4G0,5
29743
4G0,5
29744
4G0,5


29400
2x0,75
29401
2x0,75
29402
2x0,75
29403
3G0,75

Colour
black
white
other colours
black
white
other colours
black
white
other colours

black
white
other colours
black

Outer
ca. mm
5,1
5,1
5,1
5,5
5,5
5,5
6,0
6,0
6,0

5,4
5,4
5,4
5,7

Cop.
weight
kg / km
9,6
9,6
9,6
14,4
14,4
14,4
19,2
19,2
19,2

14,4
14,4
14,4
21,6

Weight
ca. kg /
km
40,0
40,0
40,0
49,0
49,0
49,0
61,0
61,0
61,0

49,0
49,0
49,0
59,0

Dimensions and specifications may be changed without prior notice. (RA01)

A 19

AWG-No.
20
20
20
20
20
20
20
20
20

18
18
18
18

Part No. No.cores x


cross-sec.
mm
29404
3G0,75
29405
3G0,75
29406
4G0,75
29407
4G0,75
29408
4G0,75
29409
5G0,75
29410
5G0,75
29411
5G0,75
29412
6G0,75
29413
6G0,75
29414
6G0,75
29415
7G0,75
29416
7G0,75
29417
7G0,75

Colour
white
other colours
black
white
other colours
black
white
other colours
black
white
other colours
black
white
other colours

Outer
ca. mm
5,7
5,7
6,3
6,3
6,3
7,1
7,1
7,1
7,8
7,8
7,8
7,8
7,8
7,8

Cop.
weight
kg / km
21,6
21,6
29,0
29,0
29,0
36,0
36,0
36,0
43,0
43,0
43,0
50,0
50,0
50,0

Weight
ca. kg /
km
59,0
59,0
72,0
72,0
72,0
87,0
87,0
87,0
98,0
98,0
98,0
108,0
108,0
108,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Masters: 29450 - ProductGroupID: PG2603 - Layout: L109_2 - Umbruch:

H05VV-F

according to DIN VDE 0281

Technical data

Cable structure

Properties

PVC-control cables to DINVDE0281 part5


and IEC60227-5, HD21.5S3
Temperature range
flexing -5C to +70C
fixed installation -40C to +70C
Nominal voltage
U0/U 300/500 V
Max. permissible operating voltage
in three-phase and one-phase
a.c. system U0/U 318/550 V
in direct current system
U0/U 413/825 V
Test voltage 2000 V
Breakdown voltage
min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5, IEC60228 cl.5 and HD383
PVC core insulation TI2 to
DINVDE0281part1
Cores colour coded to DINVDE0293-308
1x green-yellow earth core incl.
Green-yellow earth core, 3 cores and above
Cores stranded in layers with optimal
lay-length
PVC outer jacket in white or black
PVC outer jacket TM2 to DINVDE0281
part1

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
These types are also available with
UL-approbation.
The above list contains a selection of the
tyoes we carry es stock.
Other sizes available on request.
Cables with 7 cores are only availbale as
"A"-type.
6 mm in adaption (H).

Application
These cables are especially suited to use for the appliance with medium mechanical stress in households, kitchens and offices, also for
household appliances in damp and wet areas, e.g. refrigerators, washing machines, spin-driver etc. As far as this cable is admitted to the
relevant specifications of the equipment.
These cables are suited to be used for cooking and heating apparatus under the condition that cable does not come in direct contact with
hot parts of the apparatus and no other influences of heat.
The cables are suitable for fixed installation in furnitures, partition walls, decoration covering and in hollow spaces of prefabricated building
parts.
They are not qualified for use in outdoors or for use with industrial and farmer machineries, exceptionally in tailoring, etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No. No.cores x
cross-sec.
mm
29450
2x0,75
29451
2x0,75
29452
3G0,75
29453
3G0,75
29454
4G0,75
29455
4G0,75
29456
5G0,75
29457
5G0,75


29458
2x1
29459
2x1
29460
3G1
29461
3G1
29462
4G1
29463
4G1
29464
5G1
29465
5G1
29466
7G1
29467
7G1


29484
2x1,5
29485
2x1,5
29468
3G1,5
29469
3G1,5
29470
4G1,5
29471
4G1,5

Colour
black
white
black
white
black
white
black
white

black
white
black
white
black
white
black
white
black
white

black
white
black
white
black
white

Outer
ca. mm
6,4
6,4
6,8
6,8
7,4
7,4
8,3
8,3

6,8
6,8
7,2
7,2
8,0
8,0
8,8
8,8
9,8
9,8

7,6
7,6
8,2
8,2
9,2
9,2

Cop.
weight
kg / km
14,4
14,4
21,6
21,6
29,0
29,0
36,0
36,0

19,0
19,0
29,0
29,0
38,0
38,0
48,0
48,0
67,0
67,0

29,0
29,0
43,0
43,0
58,0
58,0

Weight
ca. kg /
km
50,0
50,0
60,0
60,0
73,0
73,0
88,0
88,0

57,0
57,0
73,0
73,0
85,0
85,0
105,0
105,0
131,0
131,0

82,0
82,0
95,0
95,0
117,0
117,0

AWG-No.
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16

Part No. No.cores x


cross-sec.
mm
29472
5G1,5
29473
5G1,5
29474
7G1,5
29475
7G1,5


29478
3G2,5
29479
3G2,5
29480
4G2,5
29481
4G2,5
29482
5G2,5
29483
5G2,5
29486
7G2,5
29487
7G2,5


29825
3G4
29826
3G4
29488
4G4
29489
4G4
29490
5G4
29491
5G4


29492
4G6
29493
4G6

Colour
black
white
black
white

black
white
black
white
black
white
black
white

black
white
black
white
black
white

black
white

Outer
ca. mm
9,3
9,3
10,8
10,8

10,1
10,1
11,2
11,2
12,4
12,4
12,9
12,9

11,3
11,3
12,5
12,5
13,7
13,7

13,9
13,9

Cop.
weight
kg / km
72,0
72,0
101,0
101,0

72,0
72,0
96,0
96,0
120,0
120,0
168,0
168,0

115,0
115,0
154,0
154,0
192,0
192,0

230,0
230,0

Weight
ca. kg /
km
144,0
144,0
183,0
183,0

152,0
152,0
192,0
192,0
243,0
243,0
316,0
316,0

235,0
235,0
300,0
300,0
361,0
361,0

490,0
490,0

AWG-No.
16
16
16
16

14
14
14
14
14
14
14
14

12
12
12
12
12
12

10
10

Dimensions and specifications may be changed without prior notice. (RA01)

A 20

Masters: 3011_ - ProductGroupID: PG2603 - Layout: L109_1 - Umbruch:

H05VV-F

according to DIN VDE 0281

Technical data

Cable structure

Properties

PVC-control cables to DINVDE0281 part5


and IEC60227-5, HD21.5S3
Temperature range
flexing -5C to +70C
fixed installation -40C to +70C
Nominal voltage U0/U 300/500 V
Max. permissible operating voltage
in three-phase and one-phase
a.c. system U0/U 318/550 V
in direct current system
U0/U 413/825 V
Test voltage 2000 V
Breakdown voltage
min. 4000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5, IEC60228 cl.5 and HD383
PVC core insulation TI2 to DINVDE0281
part1
Cores colour coded to DINVDE0293-308
Green-yellow earth core, 3 cores and above
Cores stranded in layers with optimal
lay-length
PVC outer jacket TM2 to DINVDE0281
part1
PVC outer jacket, colour by request

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Colour code:
0 = RAL 5015, blue
1 = RAL 6018, green
2 = RAL 8003, brown
3 = RAL 1021, yellow
4 = RAL 3000, red
5 = RAL 2003, orange
6 = RAL 4005, violet
7 = RAL 7001/7032, grey
8 = gold
9 = dusty gold
Please add the individual part no. for order
with the identification colour code.
Further colours on request.

Application
These cable are especially suited to use for the appliance with medium mechanical stress in households, kitchens and offices, also for
household appliances in damp and wet areas, e.g. refrigerators, washing machines, spin-driver etc. As far as this cable is admitted to the
relevant specifications of the equipment.
These cables are suited to be used for cooking and heating apparatus under the condition that cable does not come in direct contact with
hot parts of the apparatus and no other influences of heat.
The cables are suitable for fixed installation in furnitures, partition walls, decoration covering and in hollow spaces of prefabricated building
parts.
They are not qualified for use in outdoors or for use with industrial and farmer machineries, exceptionally in tailoring, etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
3011_
3012_
3013_
3014_

3015_
3016_
3017_
3018_

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75

2x1
3G1
4G1
5G1

Outer
app. mm
6,4
6,8
7,4
8,3

6,8
7,2
8,0
8,8

Cop.
weight
kg / km
14,4
21,6
29,0
36,0

19,0
29,0
38,0
48,0

Weight
app.
kg / km
50,0
60,0
73,0
88,0

57,0
73,0
85,0
105,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 21

18
18
18
18

17
17
17
17

Part No.
3020_
3021_
3022_
3023_

3024_
3025_
3026_

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5

3G2,5
4G2,5
5G2,5

Outer
app. mm
7,6
8,2
9,2
9,3

10,1
11,2
12,4

Cop.
weight
kg / km
29,0
43,0
58,0
72,0

72,0
96,0
120,0

Weight
app.
kg / km
82,0
95,0
117,0
144,0

152,0
192,0
243,0

AWG-No.
16
16
16
16

14
14
14

Masters: 11001 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

JB-500

flexible, colour coded, meter marking

Technical data

Cable structure

Properties

Requirements adapted to DINVDE0245,


0281, 0293, 0295
Temperature range
flexing -15C1) to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
Teil811-1-4, EN60811-1-4

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of special PVC Z7225
Cores colour coded as per JB/OB colour
code
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour grey (RAL 7001)
with meter marking, change-over in 2009

Extensively oil and Chemical Resistance


PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OB).
up to 5 cores with VDE-Reg-No.
screened analogue type:
Y-CY-JB, seepageA38

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as measuring and control cables in tool machinery, conveyor belts, production lines,
as well as in machinery production, in air-conditioning and steel production plants. The earth core is located immediately below the outer
jacket. JB cables are suitable for use in all electrical equipment either in dry or damp areas. They should not, however, be installed in the
open air. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
11001
11002
11003
11004
11005
11006
11007
11008
11009
11010
11011
11012
11013
11014
11015
11019
11026
11027
11028
11029
11030
11031
11032
11033
11034
11035
11036
11037
11038
11039
11040
11041
11042
11043
11050
11051
11052
11053
11054
11055
11056

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
6G0,5
7G0,5
7x0,5
8G0,5
10G0,5
12G0,5
14G0,5
16G0,5
30G0,5
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
6G0,75
7G0,75
7x0,75
8G0,75
9G0,75
10G0,75
12G0,75
15G0,75
18G0,75
21G0,75
25G0,75
2x1
3G1
3x1
4G1
4x1
5G1
5x1

Outer
app. mm
4,9
5,2
5,2
5,6
5,6
6,3
6,3
6,9
6,9
6,9
8,1
9,0
9,2
9,7
10,4
13,8
5,3
5,6
5,6
6,3
6,3
6,9
6,9
7,7
7,7
7,7
9,0
9,8
9,8
10,0
11,2
12,2
13,5
14,5
5,6
6,1
6,1
6,6
6,6
7,5
7,5

Cop.
weight
kg / km
9,6
14,4
14,4
19,2
19,2
24,0
24,0
29,0
34,0
34,0
38,0
48,0
58,0
67,0
77,0
144,0
14,4
21,6
21,6
28,8
28,8
36,0
36,0
43,2
50,0
50,0
58,0
65,0
72,0
86,0
108,0
130,0
151,0
180,0
19,2
29,0
29,0
38,4
38,4
48,0
48,0

Weight
app.
kg / km
40,0
46,0
46,0
56,0
56,0
65,0
65,0
75,0
80,0
84,0
97,0
116,0
135,0
150,0
172,0
310,0
46,0
54,0
54,0
66,0
66,0
80,0
80,0
99,0
110,0
110,0
130,0
153,0
162,0
179,0
218,0
257,0
320,0
365,0
60,0
72,0
72,0
86,0
86,0
104,0
104,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17

Part No.
11057
11058
11059
11060
11061
11062
11063
11064
11065
11066
11067
11068
11069
11070
11077
11078
11079
11080
11081
11082
11083
11084
11085
11086
11087
11088
11089
11090
11091
11092
11093
11094
11104
11105
11106
11107
11108
11109
11110
11111
11112

No.cores x
cross-sec.
mm
6G1
6x1
7G1
7x1
8G1
9G1
10G1
12G1
14G1
16G1
18G1
20G1
24G1
25G1
2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
6G1,5
7G1,5
7x1,5
8G1,5
11G1,5
12G1,5
14G1,5
16G1,5
18G1,5
20G1,5
25G1,5
2x2,5
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
6G2,5
7G2,5

Outer
app. mm
8,1
8,1
8,1
8,1
9,6
10,6
10,6
10,8
11,4
12,3
12,9
13,7
14,7
15,6
6,4
6,8
6,8
7,6
7,6
8,3
8,3
9,2
9,2
9,2
10,6
12,2
12,2
13,0
13,9
14,8
15,5
17,8
7,8
8,3
8,3
9,2
9,2
10,1
10,1
11,2
11,2

Cop.
weight
kg / km
58,0
58,0
67,0
67,0
77,0
87,0
96,0
115,0
134,0
154,0
173,0
192,0
230,0
240,0
29,0
43,0
43,0
58,0
58,0
72,0
72,0
86,4
101,0
101,0
115,0
158,0
173,0
202,0
230,0
259,0
288,0
360,0
48,0
72,0
72,0
96,0
96,0
120,0
120,0
144,0
168,0

Weight
app.
kg / km
125,0
125,0
141,0
141,0
175,0
200,0
207,0
230,0
271,0
300,0
343,0
375,0
468,0
485,0
70,0
90,0
90,0
109,0
109,0
131,0
131,0
157,0
184,0
184,0
216,0
300,0
309,0
345,0
386,0
440,0
490,0
620,0
112,0
148,0
148,0
178,0
178,0
221,0
221,0
293,0
306,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RA01)

A 22

Masters: 11161 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

JB-750

flexible, colour coded, 750V, meter marking

Technical data

Cable structure

Properties

Special PVC control cables


Requirements adapted to DINVDE0281,
0293, 0295 and IEC60227-5
to H05VV-F VDE0281 part5 and IEC60227-5
Type60227 IEC57
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 450/750 V
fixed installation, under protection
U0/U 600/1000 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Cores colour coded as per JB/OB colour
code
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour grey (RAL 7001)
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to DINVDE0482 part265-2-1/
EN50265-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OB).
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
screened analogue type:
Y-CY-JB, seepageA38

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as measuring and control cables in tool machinery, conveyor belts, production lines,
as well as in machinery production, in air-conditioning and steel production plants. The earth core is located immediately below the outer
jacket. JB cables are suitable for use in all electrical equipment either in dry or damp areas. They should not, however, be installed in the
open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
11161
11162
11163
11164
11165
11166
11167
11168
11169

11121
11144
11122
11123
11124
11125

11126
11127
11128
11129

11153
11130
11131
11132

11154
11133

No.cores x
cross-sec.
mm
2x2,5
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
6G2,5
7G2,5

2x4
3G4
4G4
5G4
7G4
11G4

3G6
4G6
5G6
7G6

3G10
4G10
5G10
7G10

3G16
4G16

Outer
app. mm
9,1
9,9
9,9
11,0
11,0
12,0
12,0
13,3
14,6

10,4
11,2
12,5
13,9
16,8
22,3

12,6
14,0
15,5
19,0

16,0
18,0
20,0
23,1

18,5
20,8

Cop.
weight
kg / km
48,0
72,0
72,0
96,0
96,0
120,0
120,0
144,0
168,0

76,8
115,0
154,0
192,0
269,0
422,0

173,0
230,0
288,0
403,0

290,0
384,0
480,0
672,0

461,0
614,0

Weight
app.
kg / km
130,0
164,0
164,0
200,0
200,0
247,0
247,0
301,0
321,0

195,0
235,0
295,0
361,0
498,0
767,0

355,0
424,0
525,0
625,0

611,0
701,0
858,0
1106,0

912,0
1035,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 23

14
14
14
14
14
14
14
14
14

12
12
12
12
12
12

10
10
10
10

8
8
8
8

6
6

Part No.
11134
11135

11155
11136
11137

11156
11138
11139

11157
11140
11145

11158
11141
11146

11159
11142
11147

11160
11143

11148

11149

No.cores x
cross-sec.
mm
5G16
7G16

3G25
4G25
5G25

3G35
4G35
5G35

3G50
4G50
5G50

3G70
4G70
5G70

3G95
4G95
5G95

3G120
4G120

4G150

4G185

Outer
app. mm
23,0
31,0

23,3
26,0
29,0

26,6
29,7
33,1

30,2
33,9
37,6

37,1
41,6
46,3

40,1
44,8
50,2

45,5
50,8

57,0

65,8

Cop.
weight
kg / km
768,0
1075,0

720,0
960,0
1200,0

1008,0
1344,0
1680,0

1440,0
1920,0
2400,0

2016,0
2688,0
3360,0

2736,0
3648,0
4560,0

3456,0
4608,0

5760,0

7104,0

Weight
app.
kg / km
1259,0
1780,0

1388,0
1581,0
1997,0

1767,0
2105,0
2636,0

2556,0
2940,0
3936,0

3182,0
4090,0
5443,0

4676,0
5540,0
6931,0

5630,0
7000,0

8340,0

9904,0

AWG-No.
6
6

4
4
4

2
2
2

1
1
1

2/0
2/0
2/0

3/0
3/0
3/0

4/0
4/0

300 kcmil

350 kcmil

Masters: 10334 - ProductGroupID: PG2001 - Layout: L100_1 - Umbruch:

JB-750 yellow

flexible, colour coded, 750V, connection cable for warning

indication, meter marking

Technical data

Cable structure

Properties

Special PVC as connection cable for warning


indication
Requirements adapted to 0281 part5,
HD21.5 and IEC60227/5 type227 IEC57
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 450/750 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Cores colour coded to DINVDE0293
Green-yellow earth core: 3 cores and above
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM2, to
DINVDE0281 part1
Colour yellow (RAL 1016)
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as connection cable with yellow outer sheath as a special warning indication.
Recommendation in adapted to EN60204 part1 and DINVDE0113 part1.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
10334
10335
10336

No.cores x
cross-sec.
mm
3G1,5
4G1,5
5G1,5

Outer
app. mm
8,1
9,0
10,0

Cop.
weight
kg / km
43,0
58,0
72,0

Weight
app.
kg / km
100,0
121,0
148,0

AWG-No.
16
16
16

Part No.
10337
10338
10339

No.cores x
cross-sec.
mm
3G2,5
4G2,5
5G2,5

Outer
app. mm
10,1
11,0
12,3

Cop.
weight
kg / km
72,0
96,0
120,0

Weight
app.
kg / km
154,0
208,0
229,0

AWG-No.
14
14
14

Dimensions and specifications may be changed without prior notice. (RA01)

A 24

Masters: 16531 - ProductGroupID: PG1601 - Layout: L100_1 - Umbruch:

F-CY-OZ (LiY-CY)

flexible, Cu-screened, EMC-preferred type,

meter marking

Technical data

Cable structure

Properties

Special PVC data cables, adapted to


DINVDE0245,0281 part13
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
for 1 core (LiYDY) 1200 V
Test voltage core/core 4000 V
core/screen 2000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance according to
different cross-sections
core/core approx. 150 nF/km
core/screen approx. 270 nF/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Core insulation of special PVC Z7225
Black cores with continuous numbering in
white according to DINVDE0293
Cores stranded in layers with optimal
lay-length
Core wrapping with foil
Tinned copper braided screen, approx. 85%
coverage
For 1 core cable copper screen of helically
wound (type LiYDY), approx. 85% coverage
Special PVC outer sheath TM2,to
DINVDE0281 part1 and HD21.1
Sheath colour grey (RAL7001)
with meter marking, change-over in 2009

Extensively oil resistant.


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
For 1 core cable screen of helically wound.
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
unscreened analogue type:
JZ 500, seepageA6

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air, as data cables in control technologies, in the tool making and machine industries,
in computers and as a signal cable for the electronics branch. A stabilizing separator between core bundle and braid reduces essentially the
external diameter and allows smaller bending radius, lower weight etc.
The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above
applications.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
16531
16532
16533
16534
16535
16536
16537
16538
16539
16540
16541
16542
16543

No.cores x
cross-sec.
mm
1x0,5
2x0,5
3x0,5
4x0,5
5x0,5
6x0,5
7x0,5
8x0,5
10x0,5
12x0,5
14x0,5
16x0,5
18x0,5

Outer
app. mm
3,7
5,7
6,0
6,5
7,0
7,4
7,9
8,5
9,3
9,6
10,0
10,7
11,2

Cop.
weight
kg / km
15,0
35,0
42,0
47,0
56,0
67,0
69,0
80,0
94,0
108,0
116,0
129,0
145,0

Weight
app.
kg / km
41,0
45,0
55,0
61,0
74,0
89,0
98,0
117,0
135,0
157,0
190,0
210,0
217,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 25

20
20
20
20
20
20
20
20
20
20
20
20
20

Part No.
16544
16545
16546
16547
16548
16549
16550
16551
16552
16553
16554
16555
16556

No.cores x
cross-sec.
mm
20x0,5
21x0,5
24x0,5
25x0,5
30x0,5
32x0,5
34x0,5
36x0,5
40x0,5
50x0,5
61x0,5
80x0,5
100x0,5

Outer
app. mm
11,9
12,5
12,9
13,5
14,0
14,6
15,3
15,3
16,4
18,1
19,8
21,9
24,3

Cop.
weight
kg / km
172,0
188,0
235,0
240,0
295,0
301,0
312,0
318,0
343,0
406,0
508,0
680,0
804,0

Weight
app.
kg / km
240,0
250,0
300,0
314,0
360,0
425,0
433,0
446,0
475,0
573,0
653,0
784,0
995,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
Continuation

Masters: 16531 - ProductGroupID: PG1601 - Layout: L100_1 - Umbruch:

F-CY-OZ (LiY-CY)

flexible, Cu-screened, EMC-preferred type,

meter marking
Part No.

16557
16558
16559
16560
16561
16562
16563
16564
16565
16566
16567
16568
16569
16570
16571
16572
16573
16574
16575
16576
16577
16578
16579
16580
16581
16582
16583
16584
16585

16050
16051
16052
16053
16054
16055
16056
16057
16058
16059
16060
16061
16062
16063
16064
16065
16066
16067
16068
16069
16070
16071
16072
16073

No.cores x
cross-sec.
mm

1x0,75
2x0,75
3x0,75
4x0,75
5x0,75
6x0,75
7x0,75
8x0,75
10x0,75
12x0,75
14x0,75
16x0,75
18x0,75
19x0,75
20x0,75
21x0,75
24x0,75
25x0,75
27x0,75
30x0,75
32x0,75
34x0,75
36x0,75
37x0,75
40x0,75
50x0,75
61x0,75
80x0,75
100x0,75

1x1
2x1
3x1
4x1
5x1
6x1
7x1
8x1
10x1
12x1
14x1
16x1
18x1
20x1
24x1
25x1
28x1
30x1
34x1
40x1
50x1
61x1
80x1
100x1

Outer
app. mm

3,9
6,1
6,4
6,9
7,4
8,0
8,6
9,4
10,2
10,4
11,1
11,6
12,4
12,6
12,9
13,8
14,5
15,1
15,0
15,6
16,1
16,9
16,9
17,7
18,3
20,0
21,9
24,3
26,8

4,9
6,4
6,7
7,3
7,8
8,5
9,1
9,9
10,8
11,2
11,8
12,3
13,2
13,8
15,5
16,2
16,7
16,7
18,0
19,4
21,4
23,4
26,0
28,8

Cop.
weight
kg / km


19,0
40,0
52,0
60,0
71,0
80,0
91,0
110,0
137,0
142,0
180,0
200,0
212,0
230,0
238,0
246,0
270,0
281,0
304,0
320,0
342,0
345,0
350,0
361,0
369,0
461,0
540,0
711,0
900,0

21,0
50,0
60,0
71,0
88,0
97,0
111,0
127,0
150,0
184,0
196,0
209,0
260,0
317,0
320,0
349,0
408,0
441,0
486,0
510,0
625,0
702,0
920,0
1120,0

Weight
app.
kg / km

AWG-No.


44,0
59,0
66,0
77,0
93,0
113,0
130,0
145,0
180,0
202,0
225,0
275,0
292,0
308,0
320,0
378,0
435,0
415,0
435,0
450,0
484,0
502,0
535,0
592,0
610,0
777,0
900,0
1210,0
1445,0

47,0
65,0
81,0
98,0
127,0
144,0
158,0
197,0
232,0
260,0
302,0
345,0
380,0
440,0
495,0
534,0
595,0
616,0
741,0
835,0
1025,0
1200,0
1440,0
1610,0


18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

Part No.

16074
16075
16076
16077
16078
16079
16080
16081
16082
16083
16084
16085
16086
16087
16088
16089
16090
16091
16092
16093
16094
16095
16096

16097
16098
16099
16100
16101
16102
16103

16104
16105
16106
16107
16108

16109
16110
16111
16112
16113

16114
16115
16116
16117
16118

No.cores x
cross-sec.
mm

1x1,5
2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
8x1,5
10x1,5
12x1,5
14x1,5
16x1,5
18x1,5
20x1,5
24x1,5
25x1,5
28x1,5
30x1,5
35x1,5
40x1,5
50x1,5
61x1,5
80x1,5
100x1,5

1x2,5
2x2,5
3x2,5
4x2,5
5x2,5
7x2,5
12x2,5

2x4
3x4
4x4
5x4
7x4

2x6
3x6
4x6
5x6
7x6

2x10
3x10
4x10
5x10
7x10

Outer
app. mm

5,1
7,0
7,4
8,1
8,9
10,5
11,2
12,6
12,8
13,6
14,3
15,2
15,9
17,9
18,5
19,0
19,0
20,8
22,5
24,5
27,0
30,0
33,3

5,9
8,3
9,0
9,8
10,9
12,9
15,9

9,8
10,6
11,5
12,7
14,0

11,5
12,4
13,8
15,7
16,6

14,9
15,9
17,8
19,6
21,6

Cop.
weight
kg / km


27,0
63,0
80,0
97,0
119,0
147,0
170,0
193,0
267,0
283,0
315,0
374,0
396,0
458,0
526,0
541,0
555,0
645,0
725,0
885,0
1100,0
1324,0
1641,0

39,0
96,0
144,0
148,0
181,0
255,0
441,0

120,0
174,0
230,0
273,0
316,0

173,0
240,0
305,0
439,0
505,0

255,0
350,0
535,0
592,0
810,0

Weight
app.
kg / km


70,0
88,0
100,0
126,0
160,0
208,0
244,0
316,0
338,0
383,0
424,0
479,0
545,0
690,0
705,0
810,0
830,0
890,0
1060,0
1440,0
1700,0
2000,0
2500,0

50,0
130,0
167,0
195,0
223,0
344,0
522,0

185,0
240,0
310,0
400,0
500,0

268,0
330,0
415,0
509,0
672,0

425,0
500,0
783,0
856,0
1300,0

AWG-No.

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

14
14
14
14
14
14
14

12
12
12
12
12

10
10
10
10
10

8
8
8
8
8

Dimensions and specifications may be changed without prior notice. (RA01)

A 26

Masters: 16320 - ProductGroupID: PG1601 - Layout: L100_1 - Umbruch:

F-CY-JZ

flexible, Cu-screened, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special PVC control cables, adapted to


DINVDE0245,0281 part13
Temperature range
flexing -5C to +80C
fixed installation -30C to +80C
Nominal voltage U0/U 300/500 V
Test voltage
core/core 4000 V
core/screen 2000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance according to
different cross-sections
0,5 mm to 2,5 mm:
core/core approx. 150 nF/km
core/screen approx. 270 nF/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Core insulation of special PVC Z7225
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Foil separator
Tinned copper braided screening, approx.
85% coverage
Special PVC outer sheath TM2, to special
PVC, TM2 to DINVDE0281 part1 and
HD21.1
Colour grey (RAL7001)
with meter marking, change-over in 2009

Extensively oil resistant.


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification
when ordering.
To optimise the EMC features we
recommend a large round contact of the
copper braiding on both ends.
unscreened analogue type:
JZ 500, seepageA6

Application
For use as a data cable in control circuits, in tool-making and machine industries as well as a signal cable in computer systems and electronics.
The more usual PVC inner sheath has been replaced in these cables by a stabilising foil separator, thus reducing the total diameter of the
cables considerably and thereby reducing the bending radius, total weight etc. The high covering percentage of the copper screening offers
interference-free signal transfer etc.
The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above
application.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
16320
16321
16322
16323
16324
16325
16326
16327
16328
16329
16330
16331
16332

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
6G0,5
7G0,5
8G0,5
10G0,5
12G0,5
14G0,5
16G0,5
18G0,5
20G0,5

Outer
app. mm
5,7
5,9
6,4
6,9
7,6
7,6
8,7
9,6
9,7
10,2
11,0
11,5
12,2

Cop.
weight
kg / km
35,0
42,0
47,0
56,0
67,0
69,0
80,0
94,0
108,0
116,0
129,0
145,0
172,0

Weight
app.
kg / km
45,0
55,0
61,0
74,0
89,0
98,0
117,0
135,0
157,0
190,0
210,0
217,0
240,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 27

20
20
20
20
20
20
20
20
20
20
20
20
20

Part No.
16333
16334
16335
16336
16337
16165
16338
16339
16490
16340
16341
16342
16343

No.cores x
cross-sec.
mm
21G0,5
24G0,5
25G0,5
30G0,5
32G0,5
34G0,5
36G0,5
40G0,5
41G0,5
50G0,5
61G0,5
80G0,5
100G0,5

Outer
app. mm
12,7
13,5
13,6
14,4
14,9
15,6
15,6
16,9
16,9
18,5
19,7
22,6
24,9

Cop.
weight
kg / km
188,0
235,0
240,0
295,0
301,0
312,0
318,0
343,0
348,0
406,0
508,0
680,0
804,0

Weight
app.
kg / km
250,0
300,0
314,0
360,0
425,0
433,0
446,0
475,0
486,0
573,0
653,0
784,0
995,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
20
20
Continuation

F-CY-JZ
Part No.
16344
16345
16346
16347
16348
16349
16350
16351
16353
16354
16355
16356
16447
16357
16358
16359
16360
16361
16362
16363
16166
16364
16448
16365
16491
16366
16367
16368
16369

16370
16371
16372
16373
16374
16375
16376
16377
16378
16379
16380
16381
16352
16382
16383
16384
16439
16385
16386
16387
16446
16388
16492
16389
16390
16391
16392

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
8G0,75
10G0,75
12G0,75
14G0,75
16G0,75
18G0,75
19G0,75
20G0,75
21G0,75
24G0,75
25G0,75
27G0,75
30G0,75
32G0,75
34G0,75
36G0,75
37G0,75
40G0,75
41G0,75
50G0,75
61G0,75
80G0,75
100G0,75

2x1
3G1
4G1
5G1
6G1
7G1
8G1
10G1
12G1
14G1
16G1
18G1
19G1
20G1
24G1
25G1
27G1
28G1
30G1
34G1
37G1
40G1
41G1
50G1
61G1
80G1
100G1

flexible, Cu-screened, EMC-preferred type, meter marking


Outer
app. mm
6,1
6,3
6,8
7,4
8,2
8,2
9,6
10,3
10,5
11,3
11,9
12,7
12,7
13,3
14,0
14,9
15,0
15,0
15,8
16,7
17,2
17,2
17,2
18,6
18,6
20,3
21,7
24,8
27,6

6,4
6,7
7,2
8,0
8,7
8,7
10,1
11,2
11,4
12,0
12,8
13,5
13,5
14,3
16,0
16,2
16,2
17,0
17,0
18,5
18,5
19,9
19,9
21,8
23,3
26,6
29,7

Cop.
weight
kg / km
40,0
52,0
60,0
71,0
80,0
91,0
110,0
137,0
142,0
180,0
200,0
212,0
230,0
238,0
246,0
270,0
281,0
304,0
320,0
342,0
345,0
350,0
361,0
369,0
400,0
461,0
540,0
711,0
900,0

50,0
60,0
71,0
88,0
97,0
111,0
127,0
150,0
184,0
196,0
209,0
260,0
280,0
317,0
320,0
349,0
400,0
408,0
441,0
486,0
519,0
510,0
531,0
625,0
702,0
920,0
1120,0

Weight
app.
kg / km
59,0
66,0
77,0
93,0
113,0
130,0
145,0
180,0
202,0
225,0
275,0
292,0
308,0
320,0
378,0
435,0
415,0
435,0
450,0
484,0
502,0
535,0
592,0
610,0
622,0
777,0
900,0
1210,0
1445,0

65,0
80,0
98,0
127,0
144,0
158,0
197,0
232,0
260,0
302,0
346,0
380,0
412,0
440,0
493,0
534,0
562,0
595,0
616,0
741,0
790,0
835,0
843,0
1025,0
1205,0
1445,0
1613,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

Part No.
16393
16394
16395
16396
16397
16398
16399
16400
16401
16402
16403
16449
16404
16405
16406
16407
16450
16408
16409
16410
16451
16411
16493
16412
16413
16414
16415

16416
16417
16418
16419
16420
16421
16438
16452

16422
16423
16424
16425
16426

16427
16428
16429
16430
16431

16432
16433
16434
16435
16436

16440
16437

16441
16442

16443
16444

16445

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
16G1,5
18G1,5
19G1,5
20G1,5
21G1,5
24G1,5
25G1,5
27G1,5
28G1,5
30G1,5
35G1,5
37G1,5
40G1,5
41G1,5
50G1,5
61G1,5
80G1,5
100G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
10G2,5
12G2,5
18G2,5

2x4
3G4
4G4
5G4
7G4

2x6
3G6
4G6
5G6
7G6

2x10
3G10
4G10
5G10
7G10

4G16
5G16

4G25
5G25

4G35
5G35

4G50

Outer
app. mm
7,0
7,5
8,1
9,0
9,8
11,4
12,6
12,8
13,5
14,4
15,4
15,4
16,1
17,0
18,2
18,4
18,4
19,1
19,1
20,8
20,8
22,6
22,6
24,7
26,4
30,3
33,6

8,3
9,0
9,8
10,9
11,9
15,5
15,8
18,9

9,8
10,6
11,5
12,7
14,0

11,7
12,5
13,8
15,3
16,9

14,7
15,7
17,3
19,2
21,4

20,8
22,6

24,9
27,8

28,4
31,6

34,6

Cop.
weight
kg / km
63,0
80,0
97,0
119,0
147,0
170,0
193,0
267,0
283,0
315,0
374,0
386,0
396,0
425,0
458,0
526,0
531,0
541,0
555,0
645,0
674,0
725,0
801,0
885,0
1100,0
1324,0
1641,0

96,0
144,0
148,0
181,0
255,0
340,0
441,0
570,0

120,0
174,0
230,0
273,0
316,0

173,0
240,0
305,0
439,0
505,0

255,0
350,0
535,0
592,0
810,0

740,0
895,0

1140,0
1380,0

1576,0
1930,0

2155,0

Weight
app.
kg / km
88,0
100,0
126,0
160,0
208,0
244,0
315,0
338,0
383,0
424,0
479,0
508,0
545,0
560,0
690,0
705,0
774,0
810,0
830,0
890,0
945,0
1060,0
1071,0
1290,0
1705,0
2010,0
2505,0

130,0
167,0
195,0
223,0
344,0
460,0
570,0
681,0

185,0
240,0
310,0
385,0
500,0

268,0
330,0
415,0
509,0
672,0

425,0
500,0
783,0
856,0
1305,0

880,0
1295,0

1570,0
1965,0

2070,0
2690,0

3015,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

14
14
14
14
14
14
14
14

12
12
12
12
12

10
10
10
10
10

8
8
8
8
8

6
6

4
4

2
2

1

Dimensions and specifications may be changed without prior notice. (RA01)

A 28

Masters: 13951 - ProductGroupID: PG1504 - Layout: L101_1 - Umbruch:

H05VVC4V5-K (NYSLYCY-JZ)

flexible, number

coded, oil resistant, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Control cable, special PVC with oil resistant


outer jacket to DINVDE0281 part13,
HD21.13S1 and IEC60227/74
Temperature range
flexing -5C to +70C
fixed installation -40C to +70C
Nominal voltage U0/U 300/500 V
Test voltage
core/core 2 kV, 5 min
core/screen2 kV, 5 min
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Coupling resistance
at 30 MHz 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire stranded conductor


to DINVDE0295 cl. 5, BS6360 cl.5, HD383
and IEC60228 cl.5
Special PVC core insulation TI2 to
DINVDE0281 part1
Black cores with white figure imprint to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner sheath, TM2 to
DINVDE0281 part1
Tinned copper braided screening, covering
approx. 85%
Special PVC outer jacket, TM5 to
DINVDE0281 part1, HD21.1.S4/A16
Colour grey (RAL7001)

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Oil resistant toHD/EN60811-2-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
H05VV5-F (NYSLY-JZ), seepageA12

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries,
conveyor belts and production lines. These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially
used for machines in breweries, bottling plants and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement. The
interconnection of parts of machines used for manufacturing purposes including machine tools where some degree of protection against
electromagnetic interference is required.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
13951
13060
13061
13062
13063
13064
13952
13065
13066
13953
13067
13068
13954
13069
13955
13129
13070
13071
13956

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
6G0,5
7G0,5
8G0,5
9G0,5
12G0,5
14G0,5
18G0,5
25G0,5
27G0,5
34G0,5
36G0,5
41G0,5
50G0,5
61G0,5
65G0,5

Outer
app. mm
8,0
8,4
9,1
10,1
10,7
11,4
12,5
12,5
13,5
14,2
15,8
18,6
18,6
20,8
20,8
23,0
25,0
26,8
28,4

Cop.
weight
kg / km
41,0
45,0
54,0
66,0
73,0
79,0
82,0
94,0
137,0
142,0
156,0
250,0
255,0
316,0
320,0
348,0
407,0
520,0
563,0

Weight
app.
kg / km
92,0
109,0
126,0
156,0
176,0
192,0
211,0
230,0
280,0
302,0
384,0
556,0
599,0
634,0
620,0
770,0
970,0
1072,0
1198,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 29

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Part No.
13957
13072
13073
13074
13075
13076
13958
13077
13078
13959
13079
13080
13960
13081
13961
13130
13082
13083
13962

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
8G0,75
9G0,75
12G0,75
14G0,75
18G0,75
25G0,75
27G0,75
34G0,75
36G0,75
41G0,75
50G0,75
61G0,75
65G0,75

Outer
app. mm
8,3
8,8
9,8
10,8
11,4
12,1
12,7
13,8
14,3
14,4
16,9
20,0
20,0
22,1
22,1
23,9
26,8
29,4
31,2

Cop.
weight
kg / km
46,0
57,0
63,0
76,0
82,0
100,0
112,0
130,0
175,0
190,0
240,0
306,0
326,0
346,0
358,0
403,0
470,0
550,0
594,0

Weight
app.
kg / km
102,0
115,0
150,0
173,0
195,0
235,0
268,0
285,0
327,0
362,0
488,0
654,0
708,0
821,0
899,0
970,0
1160,0
1402,0
1504,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
Continuation

Masters: 13951 - ProductGroupID: PG1504 - Layout: L101_1 - Umbruch:

H05VVC4V5-K (NYSLYCY-JZ)

flexible, number

coded, oil resistant, EMC-preferred type, meter marking


Part No.
13963
13084
13085
13086
13087
13088
13964
13089
13090
13965
13091
13966
13092
13967
13093
13968
13969
13131
13094
13095
13970

13971
13096
13097
13098
13099
13100
13972
13101
13102
13973
13103
13974
13104
13975
13105
13106
13976
13977
13132
13107
13108
13978

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
6G1
7G1
8G1
9G1
12G1
14G1
18G1
19G1
25G1
27G1
34G1
36G1
37G1
41G1
50G1
61G1
65G1

2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
9G1,5
12G1,5
14G1,5
18G1,5
19G1,5
25G1,5
27G1,5
32G1,5
34G1,5
36G1,5
37G1,5
41G1,5
50G1,5
61G1,5
65G1,5

Outer
app. mm
8,6
9,3
10,2
11,0
11,8
12,9
13,6
14,4
15,6
15,7
17,4
17,4
21,1
21,9
24,1
23,8
25,1
26,0
28,5
30,1
32,4

9,1
10,2
10,9
11,6
12,4
13,5
15,6
15,6
16,8
18,3
20,0
20,4
24,2
24,6
26,0
26,3
27,7
27,7
29,1
34,0
36,5
38,1

Cop.
weight
kg / km
54,0
64,0
76,0
89,0
101,0
114,0
130,0
144,0
186,0
198,0
284,0
307,0
387,0
410,0
500,0
511,0
523,0
578,0
681,0
710,0
769,0

64,0
82,0
99,0
123,0
125,0
148,0
172,0
187,0
274,0
294,0
386,0
394,0
531,0
546,0
638,0
671,0
700,0
720,0
840,0
997,0
1120,0
1197,0

Weight
app.
kg / km
114,0
142,0
175,0
205,0
236,0
264,0
301,0
335,0
420,0
433,0
561,0
584,0
766,0
822,0
996,0
1001,0
1018,0
1155,0
1300,0
1500,0
1510,0

146,0
176,0
207,0
235,0
279,0
314,0
345,0
380,0
500,0
560,0
707,0
723,0
950,0
1014,0
1133,0
1204,0
1261,0
1300,0
1453,0
1663,0
1852,0
1971,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Part No.
13985
13109
13110
13111
13112
13979
13113
13980
13114
13115
13981
13116
13982
13983
13117
13118

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
12G2,5
14G2,5
18G2,5
25G2,5
27G2,5
34G2,5
36G2,5
41G2,5
50G2,5
61G2,5

Outer
app. mm
11,4
11,7
12,8
13,9
15,9
18,7
20,6
22,5
24,3
29,0
29,8
33,0
33,3
36,0
38,5
42,0

Cop.
weight
kg / km
110,0
148,0
169,0
220,0
284,0
314,0
470,0
504,0
572,0
740,0
971,0
1179,0
1268,0
1473,0
1660,0
1992,0

Weight
app.
kg / km
190,0
243,0
280,0
342,0
439,0
489,0
760,0
890,0
1052,0
1375,0
1507,0
1892,0
1998,0
2286,0
2673,0
3085,0

AWG-No.
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

Dimensions and specifications may be changed without prior notice. (RA01)

A 30

Masters: 13170 - ProductGroupID: PG1504 - Layout: L100_1 - Umbruch:

(H)05VVC4V5-K ((N)YSLYCY-JZ)

number coded,

screened, oil resistant, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Control cable, special PVC with oil resistant


outer jacket to DINVDE0281 part13,
HD21.13S1 and IEC60227/74
Temperature range
flexing -5C to +70C
fixed installation -40C to +70C
Nominal voltage U0/U 300/500 V
Test voltage
core/core 2 kV, 5 min
core/screen 2 kV, 5 min
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Coupling resistance
at 30 MHz 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire stranded conductor


to DINVDE0295 cl.5, BS6360 cl.5, HD383
and IEC60228 cl.5
Special PVC core insulation TI2 to
DINVDE0281 part1
Black cores with white figure imprint to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner sheath, TM2 to
DINVDE0281 part 1
Tinned copper braided screening, covering
approx. 85%
Special PVC outer jacket, TM5 to
DINVDE0281 part1, HD21.1.S4/A16
Colour grey (RAL7001)
with meter marking, change-over in 2009.

PVC self-extinguishing and flame retardant


according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Oil resistant toHD/EN60811-2-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
(H)05VV5-F (N)YSLY-JZ, seepageA14

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries,
conveyor belts and production lines. These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially
used for machines in breweries, bottling plants and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.
The interconnection of parts of machines used for manufacturing purposes including machine tools where some degree of protection
against electromagnetic interference is required.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
13170
13171
13172
13173
13175
13178

13179
13180
13181
13182
13183

13185
13186
13187
13188

No.cores x
cross-sec.
mm
2x4
3G4
4G4
5G4
7G4
12G4

2x6
3G6
4G6
5G6
7G6

3G10
4G10
5G10
7G10

Outer
app. mm
12,5
13,9
15,7
17,1
20,5
25,5

14,6
15,7
17,3
19,5
23,1

19,9
22,0
24,6
29,5

Cop.
weight
kg / km
124,0
178,0
234,0
284,0
321,0
581,0

176,0
245,0
316,0
442,0
530,0

367,0
549,0
604,0
820,0

Weight
app.
kg / km
236,0
361,0
430,0
509,0
660,0
979,0

296,0
420,0
579,0
719,0
1031,0

655,0
894,0
927,0
1518,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 31

12
12
12
12
12
12

10
10
10
10
10

8
8
8
8

Part No.
13190
13191
13192
13193

13196
13197

13198
13199
13189

13194
13195
13184

No.cores x
cross-sec.
mm
3G16
4G16
5G16
7G16

4G25
5G25

3G35
4G35
5G35

3G50
4G50
5G50

Outer
app. mm
22,9
25,5
28,4
33,9

31,6
35,1

32,7
35,1
39,4

36,1
40,4
43,8

Cop.
weight
kg / km
653,0
807,0
940,0
1345,0

1169,0
1420,0

1250,0
1680,0
2020,0

1887,0
2370,0
2880,0

Weight
app.
kg / km
993,0
1340,0
1626,0
2080,0

1692,0
1972,0

1704,0
2320,0
2780,0

2661,0
3194,0
4247,0

AWG-No.
6
6
6
6

4
4

2
2
2

1
1
1

Masters: 16200 - ProductGroupID: PG1601 - Layout: L100_1 - Umbruch:

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking


A

Technical data

Cable structure

Properties

Special PVC control cables, adapted to


EDINVDE0245,0281 part13
Conductor resistance
to DINVDE0295
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance according
to different cross-sections
0,5 mm to 2,5 mm:
core/core approx. 150 nF/km
core/screen approx. 270 nF/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Core insulation of special PVC Z7225
Black cores with continuous white
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner sheath
Tinned copper, braided screen, approx. 85%
coverage
Transparent special PVC outer sheath
with meter marking, change-over in 2009

Extensively oil resistant.


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-500, seepageA6

Application
For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening
ensures a high degree of interference protection. The screening density assures disturbancefree transmission of all signals and impulses.
The PVC-inner sheaths of those cables raise the mechanical stress. The applied clear transparent PVC outer sheath accentuates the optical
view of the tinned copper braid.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
16200
16201
16202
16203
16204
16205
16206
16207
16208
16209
16210
16211
16212
16315
16213
16214
16215
16216
16217
16218
16453
16219
16220
16221
16222

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
6G0,5
7G0,5
8G0,5
10G0,5
12G0,5
14G0,5
16G0,5
18G0,5
20G0,5
21G0,5
24G0,5
25G0,5
30G0,5
32G0,5
36G0,5
40G0,5
41G0,5
50G0,5
61G0,5
80G0,5
100G0,5

Outer
app. mm
6,9
7,2
7,8
8,3
9,0
9,5
10,2
11,2
11,3
11,9
12,6
13,1
13,8
14,5
15,2
15,7
16,0
16,9
17,4
18,9
19,0
20,9
22,9
25,0
27,7

Cop.
weight
kg / km
41,0
45,0
54,0
66,0
73,0
79,0
82,0
107,0
137,0
142,0
147,0
156,0
173,0
189,0
236,0
250,0
297,0
312,0
320,0
345,0
348,0
407,0
520,0
690,0
805,0

Weight
app.
kg / km
67,0
83,0
94,0
108,0
125,0
136,0
150,0
170,0
195,0
223,0
250,0
277,0
310,0
331,0
390,0
407,0
520,0
550,0
585,0
654,0
671,0
740,0
850,0
1080,0
1350,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Part No.
16223
16224
16225
16226
16227
16228
16229
16230
16231
16232
16233
16234
16235
16316
16236
16237
16238
16239
16240
16241
16242
16454
16243
16244
16245
16246

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
8G0,75
10G0,75
12G0,75
14G0,75
16G0,75
18G0,75
20G0,75
21G0,75
24G0,75
25G0,75
27G0,75
30G0,75
32G0,75
36G0,75
40G0,75
41G0,75
50G0,75
61G0,75
80G0,75
100G0,75

Outer
app. mm
7,6
7,8
8,3
9,1
9,6
10,4
11,1
12,2
12,5
13,0
13,8
14,3
15,2
15,8
16,8
17,4
17,6
18,1
18,7
19,5
20,9
21,2
23,2
25,0
28,0
30,6

Cop.
weight
kg / km
46,0
57,0
63,0
76,0
82,0
100,0
112,0
140,0
175,0
190,0
204,0
240,0
262,0
274,0
291,0
306,0
326,0
340,0
349,0
358,0
371,0
403,0
470,0
550,0
715,0
910,0

Weight
app.
kg / km
87,0
98,0
113,0
130,0
156,0
184,0
221,0
270,0
292,0
315,0
335,0
358,0
420,0
454,0
480,0
508,0
535,0
640,0
688,0
730,0
950,0
971,0
1100,0
1290,0
1510,0
1640,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
Continuation

A 32

Masters: 16200 - ProductGroupID: PG1601 - Layout: L100_1 - Umbruch:

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking


Part No.

16248
16249
16250
16251
16252
16253
16254
16255
16256
16257
16258
16259
16260
16261
16262
16263
16264
16265
16266
16455
16267
16268
16269
16270

16271
16272
16273
16274
16275
16276
16277
16278
16279
16280
16281
16282
16317
16283
16284
16285
16286
16287
16288
16456
16289
16290
16291
16292

No.cores x
cross-sec.
mm

2x1
3G1
4G1
5G1
6G1
7G1
8G1
10G1
12G1
14G1
16G1
18G1
20G1
24G1
25G1
28G1
30G1
34G1
40G1
41G1
50G1
61G1
80G1
100G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
16G1,5
18G1,5
20G1,5
21G1,5
24G1,5
25G1,5
28G1,5
30G1,5
35G1,5
40G1,5
41G1,5
50G1,5
61G1,5
80G1,5
100G1,5

Outer
app. mm

7,9
8,2
8,9
9,5
10,2
11,0
11,6
13,0
13,1
13,9
14,5
15,4
16,0
17,4
18,3
18,4
18,8
20,3
21,8
22,1
24,0
26,2
29,3
33,0

8,4
9,0
9,6
10,5
12,1
13,0
14,5
14,9
15,5
16,4
17,1
18,0
18,7
19,8
20,7
21,1
21,1
22,7
24,4
24,8
26,8
29,6
33,2
36,4

Cop.
weight
kg / km


54,0
64,0
76,0
89,0
101,0
114,0
130,0
156,0
186,0
198,0
214,0
284,0
325,0
366,0
387,0
421,0
457,0
500,0
536,0
578,0
681,0
710,0
940,0
1180,0

64,0
82,0
99,0
123,0
148,0
172,0
198,0
274,0
294,0
318,0
386,0
401,0
447,0
487,0
531,0
562,0
598,0
685,0
759,0
840,0
997,0
1120,0
1360,0
1690,0

Weight
app.
kg / km

AWG-No.


97,0
103,0
146,0
169,0
199,0
219,0
270,0
330,0
350,0
400,0
422,0
514,0
545,0
640,0
689,0
710,0
762,0
910,0
1070,0
1092,0
1315,0
1370,0
1610,0
1840,0

130,0
152,0
168,0
202,0
304,0
336,0
420,0
434,0
480,0
525,0
640,0
690,0
720,0
770,0
805,0
900,0
950,0
1100,0
1350,0
1381,0
1675,0
1800,0
2300,0
2600,0

Dimensions and specifications may be changed without prior notice. (RA01)

A 33


17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Part No.
16293
16294
16295
16296
16297
16298
16318

16299
16300
16301
16302
16303

16304
16305
16306
16307
16308

16309
16310
16311
16312
16313

16460
16314

16461
16462

16463
16464

16465
16157

16466
16158

16467
16159

16468
16160

16167
16168

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
10G2,5
12G2,5

2x4
3G4
4G4
5G4
7G4

2x6
3G6
4G6
5G6
7G6

2x10
3G10
4G10
5G10
7G10

4G16
5G16

4G25
5G25

4G35
5G35

4G50
5G50

4G70
5G70

4G95
5G95

4G120
5G120

4G150
5G150

Outer
app. mm
10,0
10,7
11,4
12,5
15,0
17,9
18,0

11,6
12,3
13,4
14,8
16,2

13,5
14,2
15,6
17,0
18,7

16,8
17,8
19,7
21,6
24,0

22,6
25,2

28,9
31,8

32,2
36,4

38,2
43,0

46,8
51,8

51,0
56,0

56,0
63,0

63,5
69,5

Cop.
weight
kg / km
110,0
148,0
169,0
220,0
284,0
369,0
470,0

124,0
178,0
234,0
284,0
321,0

176,0
245,0
316,0
442,0
530,0

260,0
367,0
549,0
604,0
820,0

807,0
940,0

1169,0
1420,0

1680,0
2020,0

2370,0
2880,0

3257,0
4032,0

4060,0
5244,0

5231,0
6624,0

7760,0
8496,0

Weight
app.
kg / km
180,0
216,0
267,0
347,0
407,0
660,0
722,0

302,0
340,0
410,0
502,0
638,0

350,0
450,0
559,0
702,0
907,0

500,0
750,0
1020,0
1115,0
1500,0

1380,0
1553,0

1890,0
2270,0

2390,0
2885,0

3315,0
4150,0

4600,0
5750,0

6060,0
7580,0

7315,0
9150,0

9680,0
10170,0

AWG-No.
14
14
14
14
14
14
14

12
12
12
12
12

10
10
10
10
10

8
8
8
8
8

6
6

4
4

2
2

1
1

2/0
2/0

3/0
3/0

4/0
4/0

300 kcmil
300 kcmil

Masters: 12001 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

SY-JZ

flexible, number coded, with steel wire braiding, meter marking

Technical data

Cable structure

Properties

Special PVC control cables


Adapted to DIN VDE 0245, 0281, 0293, 0295
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 20x cable
fixed installation 6x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors,to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of special PVC Z7225
Black cores with white figure imprint to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner jacket
Galvanized steel wire screening
Special PVC outer jacket
Colour transparent (also available in grey)
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB) for
outer jacket grey
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
Further dimensions available on request.
These cables con be also delivered with
coloured conductors (SY-JB).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
screened analogue type:
SY-JB, seepageA40

Application
SY-JZ cables are used as measuring and control cables in tool machinery, plant installation, power stations and in data equipment. The braided
screen offers best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps protect
against corrosion, but also notably improves the soldering performance.
The clear transparent outer sheath gives the cable in addition an optical revaluation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
12001
12002
12003
12004
12005
12006
12007
12008
12009
12010
12114
12012
12013
12014
12015
12016
12017
12018
12011

12019
12020
12021
12022
12112
12023
12188
12024
12113
12025
12026

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
21G0,5
25G0,5
30G0,5
35G0,5
40G0,5
42G0,5
50G0,5
61G0,5
80G0,5
100G0,5

2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
8G0,75
9G0,75
10G0,75
12G0,75
15G0,75

Outer
app. mm
7,2
7,7
8,1
8,6
9,8
11,5
11,6
12,2
13,5
14,9
15,9
16,4
17,8
19,3
19,3
21,0
22,9
25,2
27,8

7,8
8,1
8,6
9,4
9,9
10,7
11,1
12,2
12,5
12,8
14,1

Cop.
weight
kg / km
9,6
14,4
19,2
24,0
33,6
48,0
58,0
67,0
86,0
101,0
120,0
144,0
168,0
192,0
202,0
240,0
293,0
384,0
480,0

14,4
21,6
28,8
36,0
43,2
50,0
57,6
65,0
72,0
86,0
108,0

Weight
app.
kg / km
80,0
92,0
102,0
119,0
157,0
205,0
218,0
242,0
340,0
370,0
406,0
439,0
500,0
565,0
593,0
690,0
843,0
1050,0
1240,0

98,0
103,0
122,0
142,0
180,0
185,0
201,0
249,0
252,0
292,0
335,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

18
18
18
18
18
18
18
18
18
18
18

Part No.
12027
12028
12029
12030
12031
12032
12033
12034

12035
12036
12037
12038
12039
12040
12041
12042
12043
12044
12045
12046
12047
12048
12049
12050
12051
12052
12053
12054
12055
12056

No.cores x
cross-sec.
mm
18G0,75
21G0,75
25G0,75
32G0,75
34G0,75
41G0,75
50G0,75
61G0,75

2x1
3G1
4G1
5G1
6G1
7G1
8G1
9G1
12G1
14G1
18G1
20G1
25G1
34G1
36G1
41G1
50G1
56G1
61G1
65G1
80G1
100G1

Outer
app. mm
14,8
16,2
17,8
18,9
19,6
21,0
23,3
25,1

8,2
8,5
9,3
9,8
10,6
11,3
12,1
12,8
13,6
14,2
15,6
16,4
18,7
20,8
20,8
22,2
24,2
24,8
26,6
27,5
29,5
33,2

Cop.
weight
kg / km
130,0
151,0
180,0
230,0
245,0
296,0
360,0
439,0

19,2
28,8
38,4
48,0
58,0
67,0
77,0
86,0
115,0
134,0
173,0
192,0
240,0
326,0
346,0
394,0
480,0
538,0
586,0
624,0
768,0
960,0

Weight
app.
kg / km
388,0
474,0
503,0
644,0
663,0
741,0
925,0
1082,0

112,0
132,0
143,0
166,0
22,0
227,0
277,0
295,0
340,0
420,0
500,0
532,0
664,0
845,0
857,0
993,0
1112,0
1225,0
1306,0
1504,0
1750,0
1950,0

AWG-No.
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
Continuation

A 34

Masters: 12001 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

SY-JZ
Part No.
12057
12058
12059
12060
12109
12061
12062
12063
12064
12065
12066
12067
12068
12069
12070
12071
12072
12073
12074
12075
12076

12077
12078
12079
12080
12081
12082
12083
12084
12085
12086
12087
12088
12089
12090

flexible, number coded, with steel wire braiding, meter marking

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
9G1,5
10G1,5
11G1,5
12G1,5
14G1,5
18G1,5
25G1,5
32G1,5
34G1,5
42G1,5
50G1,5
61G1,5
80G1,5
100G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
14G2,5
18G2,5
20G2,5
25G2,5
30G2,5
34G2,5
50G2,5
61G2,5

Outer
app. mm
8,9
9,3
9,9
10,8
11,6
12,5
13,6
14,3
14,9
15,1
15,1
15,7
17,3
20,9
22,6
22,9
24,6
27,1
29,8
33,2
36,4

10,4
11,0
11,9
12,8
15,2
18,2
18,9
21,5
22,6
25,5
26,7
28,7
34,3
37,7

Cop.
weight
kg / km
29,0
43,0
58,0
72,0
87,0
101,0
115,0
130,0
144,0
158,0
173,0
202,0
259,0
360,0
461,0
490,0
605,0
720,0
878,0
1152,0
1440,0

48,0
72,0
96,0
120,0
168,0
288,0
336,0
432,0
480,0
600,0
720,0
816,0
1200,0
1464,0

Weight
app.
kg / km
129,0
149,0
185,0
205,0
255,0
285,0
340,0
347,0
418,0
430,0
444,0
533,0
593,0
781,0
1015,0
1124,0
1401,0
1583,0
1810,0
2316,0
2900,0

185,0
248,0
290,0
347,0
420,0
660,0
750,0
893,0
1169,0
1458,0
1686,0
1869,0
2200,0
3000,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 35

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

14
14
14
14
14
14
14
14
14
14
14
14
14
14

Part No.
12115
12091
12092
12093
12094

12095
12096
12097

12098
12099
12100

12101
12102
12103

12104
12105

12106
12107

12108
12116

12111
12117

12110
12118

12119

12327

No.cores x
cross-sec.
mm
3G4
4G4
5G4
7G4
11G4

4G6
5G6
7G6

4G10
5G10
7G10

4G16
5G16
7G16

4G25
5G25

4G35
5G35

4G50
5G50

4G70
5G70

4G95
5G95

4G120

4G150

Outer
app. mm
12,6
13,9
15,0
16,4
22,0

15,8
17,2
18,9

20,0
21,9
24,2

22,9
25,5
28,0

28,9
31,8

32,2
36,4

38,2
43,2

46,8
51,8

51,4
56,4

56,3

63,5

Cop.
weight
kg / km
117,0
154,0
192,0
269,0
422,0

230,0
288,0
403,0

384,0
480,0
672,0

614,0
768,0
1075,0

960,0
1200,0

1344,0
1680,0

1920,0
2400,0

2688,0
3360,0

3648,0
4560,0

4608,0

5760,0

Weight
app.
kg / km
350,0
428,0
504,0
640,0
1204,0

571,0
671,0
845,0

943,0
1065,0
1551,0

1360,0
1740,0
2166,0

2020,0
2465,0

2570,0
3185,0

3513,0
4248,0

4810,0
5880,0

6360,0
8071,0

8170,0

9970,0

AWG-No.
12
12
12
12
12

10
10
10

8
8
8

6
6
6

4
4

2
2

1
1

2/0
2/0

3/0
3/0

4/0

300 kcmil

Masters: 11464 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

JZ-600-Y-CY

flexible, number coded, 0,6/1kV, Cu screened

meter marking, EMC-preferred type

Technical data

Cable structure

Properties

Special control cables with thermoplastic


PVC insulation On the basis of
DINVDE0262/12.95 and DINVDE0281
part13
Temperature range
flexing -5C to +80C
fixed installation -40C to +90C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Power rating
according to DIN VDE 0298
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Black cores with sequential numbering
imprinted in white, according to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
PVC-insulated inner sheath
Braided screen of tinned Cu wires, coverage
approx. 85%
Special PVC outer sheath TM2, to
DINVDE0281 part1
colour black (RAL 9005)
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Resistant to ultra violet rays

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
Further sizes are available upon request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-600, seepageA17

Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air
conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with
free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable
to be used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable,
even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located
in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and
Arabian countries. Interference-free transmission of signals and pulses is assured by the high degree of screening.
EMC = Electromagnetic compatibility
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
11464
11465
11466
11467
11469
11472
11475
11478

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5

Outer
app. mm
8,5
8,8
9,6
10,2
11,1
14,0
16,2
19,2

Cop.
weight
kg / km
41,0
45,0
54,0
66,0
79,0
137,0
156,0
250,0

Weight
app.
kg / km
129,0
150,0
170,0
199,0
235,0
320,0
428,0
503,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

20
20
20
20
20
20
20
20

Part No.

11489
11490
11491
11492
11494
11498
11501
11504

11516
11517
11518
11519
11521
11525
11528
11532

11546
11547
11548
11549
11551
11556
11559
11563

No.cores x
cross-sec.
mm

2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75

2x1
3G1
4G1
5G1
7G1
12G1
18G1
25G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5

Outer
app. mm

8,8
9,3
9,9
10,8
11,5
14,6
17,1
20,3

9,4
9,8
10,4
11,4
12,5
15,7
18,4
21,8

10,4
11,1
11,8
13,1
14,2
18,4
21,5
25,6

Cop.
weight
kg / km


46,0
57,0
63,0
76,0
100,0
175,0
240,0
306,0

54,0
64,0
76,0
89,0
114,0
186,0
284,0
387,0

64,0
82,0
99,0
123,0
148,0
274,0
386,0
531,0

Weight
app.
kg / km


143,0
155,0
190,0
228,0
323,0
410,0
560,0
730,0

150,0
163,0
200,0
239,0
289,0
464,0
628,0
855,0

162,0
187,0
240,0
289,0
383,0
592,0
806,0
1241,0

AWG-No.

18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
Continuation

A 36

Masters: 11464 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

JZ-600-Y-CY

flexible, number coded, 0,6/1kV, Cu screened

meter marking, EMC-preferred type


Part No.
11574
11575
11576
11577
11578
11580
11582
11584

11590
11591
11592
11593
11594
11596

11597
11598
11599
11600
11601

11602
11603
11604
11605
11606

11607
11608
11609

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

2x4
3G4
4G4
5G4
7G4
12G4

2x6
3G6
4G6
5G6
7G6

2x10
3G10
4G10
5G10
7G10

2x16
3G16
4G16

Outer
app. mm
11,8
12,7
13,8
15,1
16,3
21,3
25,4
30,0

14,2
15,1
16,2
18,0
19,8
25,8

15,9
16,9
18,7
20,4
22,2

18,3
19,2
21,2
23,2
26,8

22,8
24,7
27,0

Cop.
weight
kg / km
110,0
148,0
169,0
220,0
284,0
470,0
572,0
740,0

124,0
178,0
234,0
284,0
321,0
581,0

176,0
245,0
316,0
442,0
530,0

260,0
367,0
549,0
604,0
820,0

491,0
653,0
807,0

Weight
app.
kg / km
272,0
298,0
345,0
427,0
561,0
857,0
1355,0
1995,0

306,0
391,0
527,0
700,0
920,0
1510,0

420,0
629,0
731,0
1105,0
1465,0

845,0
1125,0
1345,0
1635,0
2210,0

1150,0
1395,0
1870,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 37

14
14
14
14
14
14
14
14

12
12
12
12
12
12

10
10
10
10
10

8
8
8
8
8

6
6
6

Part No.
11610
11611

11612
11613
11614
11615

11616
11617
11618

11619
11620
11621

11622
11623
11624

11625
11626
11627

11628
11629

13137

13147

No.cores x
cross-sec.
mm
5G16
7G16

3G25
4G25
5G25
7G25

3G35
4G35
5G35

3G50
4G50
5G50

3G70
4G70
5G70

3G95
4G95
5G95

3G120
4G120

4G150

4G185

Outer
app. mm
30,0
32,2

29,2
32,0
35,7
39,0

32,3
35,8
39,5

39,7
43,4
47,8

44,9
49,1
53,8

49,6
54,1
57,7

51,5
59,4

67,9

74,0

Cop.
weight
kg / km
940,0
1345,0

920,0
1169,0
1420,0
1921,0

1250,0
1680,0
2020,0

1887,0
2370,0
2880,0

2516,0
3257,0
4032,0

3086,0
4060,0
5244,0

4176,0
5231,0

7760,0

7760,0

Weight
app.
kg / km
2720,0
3213,0

2465,0
2750,0
3490,0
4980,0

3230,0
4100,0
4950,0

4590,0
5780,0
7210,0

5610,0
7480,0
9390,0

8585,0
10220,0
13800,0

11105,0
13750,0

15990,0

18470,0

AWG-No.
6
6

4
4
4
4

2
2
2

1
1
1

2/0
2/0
2/0

3/0
3/0
3/0

4/0
4/0

300 kcmil

350 kcmil

Masters: 16121 - ProductGroupID: PG1601 - Layout: L100_1 - Umbruch:

Y-CY-JB flexible, CU-screened, transparent, EMC-preferred type, meter marking


A

Technical data

Cable structure

Properties

Special PVC control cables, adapted to


EDINVDE0245,0281 part13
Conductor resistance
to DINVDE0295
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage
U0/U 300/500 V to 1,5 mm
U0/U 450/750 V at 2,5 mm
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance according to
different cross-sections
0,5 mm to 2,5 mm:
core/core approx. 150 nF/km
core/screen approx. 270 nF/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Core insulation of special PVC Z7225
Core colour coded to JB/OB colour code
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner sheath
Tinned copper, braided screen, approx. 85%
coverage
Transparent special PVC outer sheath
with meter marking, change-over in 2009

Extensively oil resistant.


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OB).
by 5 cores with VDE-Reg. No.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JB-500, seepageA22
JB-750, seepageA23

Application
For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening
ensures a high degree of interference protection. The screening density assures disturbance-free transmission of all signals and impulses.
The PVC-inner sheaths of those cables raise the mechanical stress. The applied clear transparent PVC outer sheath accentuates the optical
view of the tinned copper braid. These cables are suitable for flexible use for medium mechanical stresses with free movements.
The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above
application.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
16121
16122
16123
16124

16125
16126
16127
16128

16129
16130
16131
16132

16133
16134
16135
16136

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5

2x0,75
3G0,75
4G0,75
5G0,75

2x1
3G1
4G1
5G1

2x1,5
3G1,5
4G1,5
5G1,5

Outer
app. mm
6,9
7,2
7,8
8,3

7,6
7,8
8,3
9,1

7,9
8,2
8,9
9,5

8,4
9,0
9,6
10,5

Cop.
weight
kg / km
41,0
45,0
54,0
66,0

46,0
57,0
63,0
76,0

54,0
64,0
76,0
89,0

64,0
82,0
99,0
123,0

Weight
app.
kg / km
67,0
83,0
94,0
108,0

87,0
98,0
113,0
130,0

97,0
103,0
146,0
169,0

130,0
152,0
168,0
202,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

20
20
20
20

18
18
18
18

17
17
17
17

16
16
16
16

Part No.
16137
16138
16139
16140

16141
16142
16143
16144

16145
16146
16147
16148

16149
16150
16151
16152

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5

2x4
3G4
4G4
5G4

2x6
3G6
4G6
5G6

2x10
3G10
4G10
5G10

Outer
app. mm
11,0
11,6
12,6
13,8

12,6
13,3
14,5
15,9

14,3
15,1
16,4
18,1

17,5
18,6
20,6
22,7

Cop.
weight
kg / km
110,0
148,0
169,0
220,0

124,0
178,0
234,0
284,0

176,0
245,0
316,0
442,0

260,0
367,0
549,0
604,0

Weight
app.
kg / km
180,0
216,0
267,0
347,0

302,0
340,0
410,0
502,0

350,0
450,0
559,0
702,0

500,0
750,0
1020,0
1115,0

AWG-No.
14
14
14
14

12
12
12
12

10
10
10
10

8
8
8
8
Continuation

A 38

Masters: 16121 - ProductGroupID: PG1601 - Layout: L100_1 - Umbruch:

Y-CY-JB flexible, CU-screened, transparent, EMC-preferred type, meter marking


Part No.
16153
16154

16469
16155

16470
16156

16471
16119

No.cores x
cross-sec.
mm
4G16
5G16

4G25
5G25

4G35
5G35

4G50
5G50

Outer
app. mm
24,5
27,2

30,6
33,7

33,8
37,8

39,8
44,8

Cop.
weight
kg / km
807,0
940,0

1169,0
1420,0

1680,0
2020,0

2370,0
2880,0

Weight
app.
kg / km
1380,0
1553,0

1890,0
2270,0

2390,0
2885,0

3315,0
4150,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 39

Part No.
6
6

4
4

2
2

1
1

16472

16473

16474

16247

16319

No.cores x
cross-sec.
mm
4G70

4G95

4G120

4G150

4G185

Outer
app. mm
48,1

52,7

58,6

65,7

73,0

Cop.
weight
kg / km
3257,0

4060,0

5231,0

7760,0

7760,0

Weight
app.
kg / km
4600,0

6060,0

7315,0

9340,0

11120,0

AWG-No.
2/0

3/0

4/0

300 kcmil

350 kcmil

Masters: 12200 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

SY-JB

flexible, colour coded, with steel wire braiding, meter marking

Technical data

Cable structure

Properties

Special PVC control cables


Adapted to DINVDE 0245, 0281, 0293, 0295
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage
U0/U 300/500 V up to 2,5 mm
U0/U 450/750 V as of 4,0 mm
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 20x cable
fixed installation 6x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of special PVC Z7225
Cores colour coded as per JB/OB colour
code, see Technical Informations
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special PVC inner jacket
Galvanized steel wire screening
Special PVC outer jacket
Colour transparent (also available in grey)
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OB).
Further dimensions available on request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification
when ordering.
screened analogue type:
SY-JZ, seepageA34

Application
SY-JB cables are used as measuring and control cables in tool machinery, plant installation, power stations and in data equipment. The
braided screen offers best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps
protect against corrosion, but also notably improves the soldering performance.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
12200
12201
12202
12203
12204
12205
12206

12218
12219
12220
12221
12312
12222
12223
12313
12224

12234
12235
12236
12237
12238
12239
12240
12241
12242

12256
12257
12258
12259
12260
12261
12262
12263
12264

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5

2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
9G0,75
10G0,75
12G0,75

2x1
3G1
4G1
5G1
6G1
7G1
8G1
9G1
12G1

2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
8G1,5
9G1,5
10G1,5

Outer
app. mm
7,2
7,7
8,1
8,6
9,8
11,5
11,6

7,8
8,1
8,6
9,4
9,9
10,7
12,2
12,5
12,8

8,2
8,5
9,3
9,8
10,6
11,3
12,1
12,8
13,6

8,9
9,3
9,9
10,8
11,6
12,5
13,6
14,3
14,9

Cop.
weight
kg / km
9,6
14,4
19,2
24,0
33,6
48,0
58,0

14,4
21,6
28,8
36,0
43,2
50,0
65,0
72,0
86,0

19,2
28,8
38,4
48,0
58,0
67,0
77,0
86,0
115,0

29,0
43,0
58,0
72,0
87,0
101,0
115,0
130,0
144,0

Weight
app.
kg / km
80,0
92,0
102,0
119,0
157,0
205,0
218,0

98,0
103,0
122,0
142,0
180,0
185,0
249,0
252,0
292,0

112,0
132,0
143,0
166,0
220,0
227,0
277,0
295,0
340,0

129,0
149,0
185,0
205,0
255,0
285,0
340,0
347,0
418,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

20
20
20
20
20
20
20

18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16

Part No.
12265
12266

12277
12278
12279
12280
12281
12282

12291
12318
12292
12293
12294

12295
12296
12297
12298

12319
12299
12300
12301

12320
12302
12303
12304

12321
12305
12306

No.cores x
cross-sec.
mm
11G1,5
12G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5

2x4
3G4
4G4
5G4
7G4

3G6
4G6
5G6
7G6

3G10
4G10
5G10
7G10

3G16
4G16
5G16
7G16

3G25
4G25
5G25

Outer
app. mm
15,1
15,1

10,4
11,0
11,9
12,8
15,2
18,2

11,9
12,6
13,9
15,0
16,4

14,5
15,8
17,2
18,9

18,0
20,0
21,9
24,2

21,0
22,9
25,5
28,0

26,2
28,9
31,8

Cop.
weight
kg / km
158,0
173,0

48,0
72,0
96,0
120,0
168,0
288,0

77,0
115,0
154,0
192,0
269,0

173,0
230,0
288,0
403,0

288,0
384,0
480,0
672,0

461,0
614,0
768,0
1075,0

720,0
960,0
1200,0

Weight
app.
kg / km
430,0
444,0

185,0
248,0
290,0
347,0
420,0
660,0

330,0
375,0
428,0
504,0
640,0

543,0
571,0
671,0
845,0

735,0
943,0
1065,0
1551,0

1080,0
1360,0
1740,0
2166,0

1630,0
2020,0
2465,0

AWG-No.
16
16

14
14
14
14
14
14

12
12
12
12
12

10
10
10
10

8
8
8
8

6
6
6
6

4
4
4

Continuation

A 40

Masters: 12200 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

SY-JB
Part No.
12322
12307
12308

12323
12309
12314

12324
12310
12315

flexible, colour coded, with steel wire braiding, meter marking

No.cores x
cross-sec.
mm
3G35
4G35
5G35

3G50
4G50
5G50

3G70
4G70
5G70

Outer
app. mm
31,6
32,2
36,4

37,4
38,2
43,2

46,0
46,8
51,8

Cop.
weight
kg / km
1008,0
1344,0
1680,0

1440,0
1920,0
2400,0

2016,0
2688,0
3360,0

Weight
app.
kg / km
1932,0
2570,0
3185,0

2679,0
3513,0
4248,0

2790,0
4810,0
5880,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA01)

A 41

2
2
2

1
1
1

2/0
2/0
2/0

Part No.
12325
12311
12316

12326
12317

12328

No.cores x
cross-sec.
mm
3G95
4G95
5G95

3G120
4G120

4G150

Outer
app. mm
48,9
51,5
56,4

51,7
56,3

63,5

Cop.
weight
kg / km
2736,0
3648,0
4560,0

3456,0
4608,0

5760,0

Weight
app.
kg / km
4870,0
6360,0
8071,0

6230,0
8170,0

9970,0

AWG-No.
3/0
3/0
3/0

4/0
4/0

300 kcmil

JZ-500 PUR
PUR-JZ
PUR-ORANGE
PUR-YELLOW
H05 BQ-F / H07 BQ-F* (NGMH11Y)
UNIPUR
PUR-750
JZ 500-FC-PUR
F-C-PUR-JZ
Y-C-PUR-JZ
UNIPUR-CP
PUR-C-PUR
Photo: Hller Hille GmbH

PUR Control Cables


The machinery and plant industries but especially
the tool making industries are working particularly with mineral oils, alkalis and aggressive collant
emulsions and under difcult working environmental conditions.
Due to these conditions the electrical control
cables, data cables as well as cables for trailing
chains have to perform to exceptionally high
standards. Flexibility, abrasion and oil resistance
have to be guaranteed.

HELUKABEL in co-operation with the leading


machine and plant industries have developed
suitable and application orientated cables.
These cables are tested, among other things,
with PUR cables are tested among the others,
mineral and synthetic oils, cutting oils, coolant
emulsions, etc. For the operation in power
trailing chains, these cables are tested to
multimillion alternating bending cycles.
Consequently we believe that we can deliver the
right cable for your application needs.

A 42

31472-00e-A042.indd Abs1:43

03.04.2009 7:39:25 Uhr

Masters: 23314 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

JZ-500 PUR

tear and coolant resistant, meter marking

Technical data

Cable structure

Special PUR cables adapted to


DINVDE0245,0281
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Special PVC core insulation TI2, according
to DINVDE0281 part1
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special full-polyurethane outer jacket
TMPU, to DINVDE0282 part10, appendixA
Sheath colour grey (RAL 7001)
Jacket also available in other colours
with meter marking, change-over in 2009

Properties

Resistant to
UV-Radiation, Oxygene, Ozone and
hydrolysis Microbes
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
screened analogue type:
JZ-500-FC-PUR, seepageA52

Application
JZ-500 PUR is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance coolant emulsions,
it is especially suited for use in the machine, tool making and plant industries as well as in the steel industry for difficult and problem areas.
The high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
23314
23315
23316
23317
23318
23319
23320
23321
23322
23323
23324
23325
23326
23327
23328

23329
23330
23331
23332
23333
23334
23335
23336
23337
23338
23339
23340
23341
23342
23343

23344
23345
23346
23347
23348
23349
23350
23351
23352
23353

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5
7x0,5
10G0,5
12G0,5
18G0,5
25G0,5
34G0,5
42G0,5

2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
10G0,75
12G0,75
18G0,75
25G0,75
34G0,75
42G0,75

2x1
3G1
3x1
4G1
4x1
5G1
5x1
7G1
7x1
10G1

Outer
app. mm
4,8
5,1
5,1
5,7
5,7
6,2
6,2
7,2
7,2
8,8
9,1
10,7
13,2
14,7
15,8

5,4
5,7
5,7
6,2
6,2
6,8
6,8
8,1
8,1
9,6
9,6
11,9
14,5
16,3
17,7

5,7
6,0
6,0
6,6
6,6
7,1
7,1
8,6
8,6
10,2

Cop.
weight
kg / km
9,6
14,4
14,4
19,0
19,0
24,0
24,0
33,6
33,6
48,0
58,0
86,0
120,0
163,0
202,0

14,4
21,6
21,6
29,0
29,0
36,0
36,0
50,0
50,0
72,0
86,0
130,0
180,0
245,0
302,0

19,0
29,0
29,0
38,0
38,0
48,0
48,0
67,0
67,0
96,0

Weight
app.
kg / km
45,0
55,0
55,0
65,0
65,0
75,0
75,0
90,0
90,0
120,0
135,0
205,0
270,0
380,0
415,0

44,0
53,0
53,0
64,0
64,0
76,0
76,0
96,0
96,0
140,0
170,0
260,0
282,0
475,0
600,0

53,0
63,0
63,0
75,0
75,0
89,0
89,0
115,0
115,0
166,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

A 43

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17

Part No.
23354
23355
23356
23357
23358
23359

23360
23361
23362
23363
23364
23365
23366
23367
23368
23369
23370
23371
23372

23373
23374
23375
23376
23377
23378

23379
23380
23381

23382
23383
23384

23385
23386
23387

23388

No.cores x
cross-sec.
mm
12G1
18G1
25G1
34G1
42G1
50G1

2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
7G1,5
7x1,5
12G1,5
18G1,5
25G1,5
30G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5

4G4
5G4
7G4

4G6
5G6
7G6

4G10
5G10
7G10

4G16

Outer
app. mm
10,7
12,9
14,9
17,4
18,8
20,9

6,2
6,6
6,6
7,2
7,2
8,2
8,2
9,8
9,8
12,0
14,5
17,8
18,0

7,8
8,3
9,2
10,1
12,3
15,3

11,0
12,7
14,0

13,4
14,9
16,5

16,9
18,7
20,9

19,8

Cop.
weight
kg / km
115,0
173,0
240,0
326,0
403,0
480,0

29,0
43,0
43,0
58,0
58,0
72,0
72,0
101,0
101,0
173,0
259,0
360,0
410,0

48,0
72,0
96,0
120,0
168,0
288,0

154,0
192,0
269,0

230,0
288,0
403,0

384,0
480,0
672,0

614,0

Weight
app.
kg / km
201,0
289,0
380,0
645,0
730,0
890,0

68,0
87,0
87,0
106,0
106,0
131,0
131,0
173,0
173,0
293,0
454,0
641,0
800,0

110,0
146,0
183,0
222,0
293,0
512,0

291,0
355,0
503,0

468,0
570,0
808,0

720,0
894,0
1295,0

1063,0

AWG-No.
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16

14
14
14
14
14
14

12
12
12

10
10
10

8
8
8

6

Masters: 22100 - ProductGroupID: PG1501 - Layout: L101-12_1 - Umbruch:

PUR-JZ

tear and coolant resistant, increased oil resistant, meter marking

Technical data

Cable structure

Properties

Special PUR cables adapted to


DINVDE0245,0281
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Oil resistant PVC core insulation TI2, in
adapted to DINVDE0281 part1, for better
sliding abilities
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special full-polyurethane outer jacket
TMPU, to DINVDE0282 part10, appendixA
Sheath colour grey (RAL 7001)
Jacket also available in other colours
with meter marking, change-over in 2009

Resistant to
UV-Radiation, Oxygene
Ozone and hydrolysis
Microbes
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
F-C-PUR-JZ, seepageA54
Y-C-PUR-JZ, seepageA56

Application
PUR-JZ is an extremely robust control cable with high abrasion and tear resistant properties. With high-grade oil resistant PVC core insulation.
Due to its high resistance to mineral oils and especially to coolant emulsions, it is especially suited for use in the machine, tool making and
plant industries as well as in the steel industry for difficult and problem areas. The high flexibility of this cable type makes it quick and easy
to install. Suitable for outdoor lying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
22100
22101
22102
22103
22104
22105
22106
22107
22108
22109
22110
22111
22112
22113
22114
22115

22116
22117
22118
22119
22120
22121
22122
22123
22124
22125
22126
22127
22128
22129
22130
22131

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
8G0,5
10G0,5
12G0,5
14G0,5
18G0,5
21G0,5
25G0,5
30G0,5
34G0,5
42G0,5
50G0,5

2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
8G0,75
10G0,75
12G0,75
14G0,75
18G0,75
21G0,75
25G0,75
30G0,75
34G0,75
42G0,75
50G0,75

Outer
app. mm
4,8
5,1
5,7
6,2
7,2
8,0
8,8
9,1
9,5
10,7
12,0
13,2
13,5
14,7
15,8
17,5

5,4
5,7
6,2
6,8
8,1
8,7
9,6
9,9
10,4
11,9
13,3
14,5
15,0
16,3
17,7
19,4

Cop.
weight
kg / km
9,6
14,4
19,0
24,0
33,6
38,0
48,0
58,0
67,0
86,0
96,0
120,0
144,0
163,0
202,0
240,0

14,4
21,6
29,0
36,0
50,0
58,0
72,0
86,0
101,0
130,0
151,0
180,0
216,0
245,0
302,0
360,0

Weight
app.
kg / km
45,0
55,0
65,0
75,0
90,0
105,0
120,0
135,0
170,0
205,0
225,0
270,0
315,0
380,0
415,0
550,0

44,0
53,0
64,0
76,0
96,0
111,0
140,0
170,0
202,0
260,0
269,0
282,0
400,0
475,0
600,0
720,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

Part No.
22132
22133
22134
22135
22136
22137
22138
22139
22140
22141
22142
22143
22144
22145
22146
22147

22148
22149
22150
22151
22152
22153
22154
22155
22156
22157
22158
22159
22160
22161
22162
22163

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
8G1
10G1
12G1
14G1
18G1
21G1
25G1
32G1
34G1
42G1
50G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
18G1,5
21G1,5
25G1,5
30G1,5
34G1,5
42G1,5
50G1,5

Outer
app. mm
5,7
6,0
6,6
7,1
8,6
9,4
10,2
10,7
11,5
12,9
14,1
14,9
16,7
17,4
18,8
20,9

6,2
6,6
7,2
8,0
9,6
10,5
11,4
12,0
12,5
14,1
15,0
16,8
18,0
19,5
21,1
25,4

Cop.
weight
kg / km
19,0
29,0
38,0
48,0
67,0
77,0
96,0
115,0
134,0
173,0
196,0
240,0
308,0
326,0
403,0
480,0

29,0
43,0
58,0
72,0
101,0
115,0
144,0
173,0
202,0
259,0
302,0
360,0
410,0
490,0
605,0
720,0

Weight
app.
kg / km
53,0
63,0
75,0
89,0
115,0
131,0
166,0
201,0
230,0
289,0
306,0
380,0
620,0
645,0
730,0
890,0

68,0
87,0
106,0
131,0
173,0
199,0
245,0
293,0
347,0
454,0
534,0
641,0
800,0
945,0
1100,0
1250,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Continuation

A 44

Masters: 22100 - ProductGroupID: PG1501 - Layout: L101-12_1 - Umbruch:

PUR-JZ
Part No.
22164
22165
22166
22167
22168
22169
22170
22171

22172
22173
22174
22175
22176

22177
22178
22179
22180

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

2x4
3G4
4G4
5G4
7G4

3G6
4G6
5G6
7G6

tear and coolant resistant, increased oil resistant, meter marking

Outer
app. mm
7,8
8,3
9,2
10,1
12,3
15,3
18,2
22,3

9,6
10,4
11,4
12,7
14,0

12,1
13,4
14,9
16,5

Cop.
weight
kg / km
48,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0

77,0
115,0
154,0
192,0
269,0

173,0
230,0
288,0
403,0

Weight
app.
kg / km
110,0
146,0
183,0
222,0
293,0
512,0
740,0
940,0

147,0
228,0
291,0
355,0
503,0

362,0
468,0
570,0
808,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

A 45

14
14
14
14
14
14
14
14

12
12
12
12
12

10
10
10
10

Part No.
22181
22182
22183
22184

22185
22186
22187

22188

22189

22190

22191

22192

No.cores x
cross-sec.
mm
3G10
4G10
5G10
7G10

4G16
5G16
7G16

4G25

4G35

4G50

4G70

4G95

Outer
app. mm
15,2
16,9
18,7
20,9

19,8
22,2
29,3

29,4

32,8

38,9

44,7

50,0

Cop.
weight
kg / km
288,0
384,0
480,0
672,0

614,0
768,0
1075,0

960,0

1344,0

1920,0

2688,0

3648,0

Weight
app.
kg / km
555,0
720,0
894,0
1295,0

1063,0
1400,0
1800,0

1590,0

2200,0

2400,0

4400,0

6000,0

AWG-No.
8
8
8
8

6
6
6

4

2

1

2/0

3/0

Masters: 22001 22250 - ProductGroupID: PG2001 - Layout: L100_2 - Umbruch:

PUR-ORANGE

high abrasion, coolant resistant, meter marking

Technical data

Cable structure

Properties

Special PVC/PUR control cable, adapted to


DINVDE0281,0282
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Cores colour identification: cores with
number or colour coded to
DINVDE0293-308
For 2-cores cable without green-yellow
earth core, core colours brown, blue black
Cores stranded in layers with optimal
lay-length
PVC-inner-sheath guarantees easy cable
stripping
PUR-outer jacket TMPU, to DINVDE0282
part10, appendixA
Colour orange (RAL2003)
with meter marking, change-over in 2009

High flexibility at low temperature


High abrasion resistance
Resistant to
Oils and fats
Non-alcoholic fuels and kerosene
Atmospheric influences
UV-radiation, Oxygene and ozone
Microbes and rotting
Sea and waste water, vibrations
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core
(OZ/OB).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Robust control cable with an outstanding resistance to oil and abrasion. Suitable for use in tool making and machine industries, steel works,
on building sites and in the oil and coal industries. The cable can also be used for portable tools etc. To be recommended if the cable comes
into contact with chemical agents.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
PUR-jacket orange, cores numbered OZ/JZ
Part No.
22001
22002
22003
22004
22005

22006
22007
22008
22009
22010

22015
22016
22017
22018
22019

22025
22026
22027
22028
22029

22033
22034
22035
22036

22037
22038
22039

22040
22041

22042
22043

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75

2x1
3G1
4G1
5G1
7G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5

3G4
4G4
5G4
7G4

4G6
5G6
7G6

4G10
5G10

4G16
5G16

Outer
app. mm
6,4
6,8
7,3
8,2
9,2

7,2
7,6
8,0
8,8
10,0

7,8
8,3
9,0
9,7
11,2

9,2
9,6
11,0
12,0
13,7

11,8
13,2
14,8
16,4

15,4
17,0
20,8

20,8
22,6

23,0
27,4

Cop.
weight
kg / km
14,4
21,6
28,8
36,0
50,0

19,2
29,0
38,0
48,0
67,0

29,0
43,0
58,0
72,0
101,0

48,0
72,0
96,0
120,0
168,0

115,0
154,0
192,0
269,0

230,0
288,0
403,0

384,0
480,0

614,0
768,0

Weight
app.
kg / km
50,0
70,0
80,0
100,0
140,0

63,0
76,0
95,0
120,0
170,0

80,0
105,0
135,0
158,0
221,0

150,0
173,0
203,0
253,0
356,0

250,0
300,0
370,0
500,0

480,0
583,0
780,0

740,0
920,0

1100,0
1400,0

PUR-jacket orange OB/JB, cores colour coded to DIN VDE 0293


AWG-No.
18
18
18
18
18

17
17
17
17
17

16
16
16
16
16

14
14
14
14
14

12
12
12
12

10
10
10

8
8

6
6

Part No.
22250
22251
22252
22253

22254
22255
22256
22257

22258
22259
22260
22261

22262
22263
22264
22265

22266
22267

22268
22269

22270
22271

22272
22273

22044
22045

22046

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75

2x1
3G1
4G1
5G1

2x1,5
3G1,5
4G1,5
5G1,5

2x2,5
3G2,5
4G2,5
5G2,5

4G4
5G4

4G6
5G6

4G10
5G10

4G16
5G16

4G25
5G25

4G35

Outer
app. mm
6,4
6,8
7,3
8,2

7,2
7,6
8,0
8,8

7,8
8,3
9,0
9,7

9,2
9,6
11,0
12,0

13,2
14,8

15,4
17,0

20,8
22,6

23,0
27,4

30,0
32,2

33,0

Cop.
weight
kg / km
14,4
21,6
28,8
36,0

19,2
29,0
38,0
48,0

29,0
43,0
58,0
72,0

48,0
72,0
96,0
120,0

154,0
192,0

230,0
288,0

384,0
480,0

614,0
768,0

960,0
1200,0

1344,0

Weight
app.
kg / km
50,0
70,0
80,0
100,0

63,0
76,0
95,0
120,0

80,0
105,0
135,0
158,0

150,0
173,0
203,0
253,0

300,0
370,0

480,0
583,0

740,0
920,0

1100,0
1400,0

1600,0
2000,0

2100,0

AWG-No.
18
18
18
18

17
17
17
17

16
16
16
16

14
14
14
14

12
12

10
10

8
8

6
6

4
4

2

Dimensions and specifications may be changed without prior notice. (RA02)

A 46

Masters: 22200 - ProductGroupID: PG2001 - Layout: L100_1 - Umbruch:

PUR-YELLOW PVC-inner jacket, high abrasion, coolant resistant, meter marking

Technical data

Cable structure

Properties

Special PVC/PUR cable adapted to


DINVDE0281,0282
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Special PVC core insulation TI2, to
DINVDE0281 part1
Core identification to DINVDE0293-308
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
PVC inner sheath guarantees easy cable
stripping
PUR-outer jacket, TMPU, to DINVDE0282
part10, appendixA
Colour yellow (RAL 1021)
with meter marking, change-over in 2009

High flexibility at low temperature


High abrasion resistance
Resistant to
Oils and fats
Non-alcoholic fuels and kerosene
Atmospheric influences
UV-radiation
Oxygene and ozone
Microbes and rotting
Sea and waste water
Vibrations
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OB).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Further jacket colours e.g. black, green etc.
on request.
Art.no. 22212 = JB.
Art.no. 22220 = JZ.

Application
Robust control cable with an outstanding resistance to oil and abrasion. Suitable for use in tool making and machine industries, steel works,
on building sites and in the oil and coal industries. The cable can also be used for portable tools. etc. To be recommended if the cable comes
into contact with chemical agents.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
22200
22201
22202
22203
22204

22205
22206
22207
22208
22209

22210
22211
22220
22212
22213
22214

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75

2x1
3G1
4G1
5G1
7G1

2x1,5
3G1,5
4G1,5
4G1,5
5G1,5
7G1,5

Outer
app. mm
6,4
6,8
7,3
8,2
9,2

7,2
7,6
8,0
8,8
10,0

7,8
8,3
9,0
9,0
9,7
11,2

Cop.
weight
kg / km
14,4
21,6
28,8
36,0
50,0

19,2
29,0
38,0
48,0
67,0

29,0
43,0
58,0
58,0
72,0
101,0

Weight
app.
kg / km
50,0
70,0
80,0
100,0
140,0

63,0
76,0
95,0
120,0
170,0

80,0
105,0
135,0
135,0
158,0
221,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

A 47

18
18
18
18
18

17
17
17
17
17

16
16
16
16
16
16

Part No.
22215
22216
22217
22218
22219

22221
22222

22233

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5

4G4
5G4

4G35

Outer
app. mm
9,2
9,6
11,0
12,0
13,7

14,6
14,8

33,0

Cop.
weight
kg / km
48,0
72,0
96,0
120,0
168,0

153,6
192,0

1344,0

Weight
app.
kg / km
150,0
173,0
203,0
253,0
356,0

310,0
370,0

2100,0

AWG-No.
14
14
14
14
14

12
12

2

Masters: 22050 22058 - ProductGroupID: PG2001 - Layout: L107_2 - Umbruch:

H05 BQ-F / H07 BQ-F* (NGMH11Y) EPR-insulated


power cables with PUR jacket

Technical data

Cable structure

Properties

EPR/PUR-insulated power cable according


to DINVDE0282 part10 and HD22.10S1
Temperature range
flexing -40C to +80C
fixed installation -50C to +90C
Permissible operating temperature
at conductor 90C
Nominal voltage a.c., 50 Hz
H05BQ-F: U0/U 300/500 V up to 1 mm
H07BQ-F: U0/U 450/750 V as of 1,5 mm
Test voltage
H05BQ-F: 2000 V up to 1 mm
H07BQ-F: 2500 V as of 1,5 mm
Minimum bending radius
flexing 5x cable
fixed installation 3x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Plain copper conductor, stranded according


to DINVDE0295 cl.5, BS6360 cl.5 and
HD383 cl.5
Insulating jacket of rubber, compound EI6
according to DINVDE0282 part1
Core identification according to
DINVDE0293-308 and HD308 S2
Green-yellow earth core in the outer layer
Cores stranded in layers with optimal
lay-length (inner protection sheath
permissible)
PUR-insulated outer jacket TMPU, to
DINVDE0282 part10, appendixA
Colour orange (RAL2003)
Minimum imprinted designation BQ

Abrasion resistant
Notch resistant
Resistant to tearing and cutting
Good flexibility at low temperatures down
to -40C
Resistant to
Oils and fats
Petrol
Water and weathering effects
Oxygene and ozone
UV-radiation
Hydrolysis
Microbial attack
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core.
These harmonized types H05BQ-F and
H07BQ-F replace the VDE-standardised
types.
7 G 1,5 mm and 12 G 1,5 mm are not
contained in VDE, adapted to VDE, (H)07BQ.

Application
These cables can be used for medium mechanical loads in dry, damp or wet environments, e.g. for connecting agricultural and commercial
equipment and heaters provided there is no danger of contact with the hot parts or by radiation of heat. These robust and flexible cables
are used for electrical tools such as drills and hand-held circular saws, as well as for portable motors and machinery in agriculture, at building
sites, docks and refrigeration plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
H05BQ-F
Part No.
22050
22051
22052
22053
22054
22055
22056
22057

H07BQ-F*
No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
2x1
3G1
4G1
5G1

Outer
Cop.
min - max
weight
ca. mm
kg / km
5,7 - 7,4
14,4
6,2 - 8,1
21,6
6,8 - 8,8
29,0
7,6 - 9,9
36,0
6,1 - 8,0
19,2
6,5 - 8,5
29,0
7,1 - 9,3
38,4
8,0 - 10,3
48,0

Weight
ca. kg / km

Outer
Cop.
min - max
weight
ca. mm
kg / km
7,6 - 9,8
29,0
8,0 - 10,4
43,0
9,0 - 11,6
58,0
9,8 - 12,7
72,0
13,0 - 15,0
101,0
17,0 - 20,0
173,0
9,0 - 11,6
48,0
9,6 - 12,4
72,0
10,7 - 13,8
96,0

Weight
ca. kg / km

52,0
63,0
80,0
96,0
59,0
71,0
89,0
112,0

AWG-No.
18
18
18
18
17
17
17
17

H07BQ-F*
Part No.
22058
22059
22060
22061
22062
22063
22064
22065
22066

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
2x2,5
3G2,5
4G2,5

92,0
109,0
145,0
169,0
230,0
398,0
121,0
164,0
207,0

AWG-No.
16
16
16
16
16
16
14
14
14

Part No.
22067
22072
22068
22069
22080
22073
22070
22071
22081
22074
22076
22078
22082
22075
22077
22079
22083

No.cores x
cross-sec.
mm
5G2,5
2x4
3G4
4G4
5G4
2x6
3G6
4G6
5G6
2x10
3G10
4G10
5G10
2x16
3G16
4G16
5G16

Outer
Cop.
min - max
weight
ca. mm
kg / km
11,9 - 15,3
120,0
10,6 - 13,7
77,0
11,3 - 14,5
115,0
12,7 - 16,2
154,0
14,1 - 17,9
192,0
11,8 - 15,1
115,0
12,8 - 16,3
173,0
14,2 - 18,1
230,0
15,7 - 20,0
288,0
15,6 - 19,9
192,0
16,8 - 21,4
288,0
18,6 - 23,6
384,0
20,4 - 25,9
480,0
17,9 - 22,8
307,0
19,5 - 24,7
461,0
21,3 - 27,0
614,0
23,7 - 30,0
768,0

Weight
ca. kg / km
262,0
194,0
224,0
327,0
415,0
311,0
310,0
496,0
586,0
428,0
640,0
738,0
968,0
600,0
758,0
1187,0
1475,0

AWG-No.
14
12
12
12
12
10
10
10
10
8
8
8
8
6
6
6
6

Dimensions and specifications may be changed without prior notice. (RA02)

A 48

Masters: 1812_ - ProductGroupID: PG2001 - Layout: L109_1 - Umbruch:

UNIPUR flexible at low temperature, with customer markings, halogen-free,


wear resistant, robust, meter marking

Technical data

Cable structure

Properties

Spezial TPE/PUR connecting cable adapted


to DIN VDE 0282 part 10
Temperature range
flexing -40C to +90C
Nominal voltage
up to 1 mm U0/U 300/500 V
above 1,5 mm U0/U 450/750 V
Test voltage 3000 V
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductions bunch


stranded according to DINVDE0295 cl.5,
BS6360 cl.5 and IEC60228 cl.5
Core insulation of termoplastic elastomere
(TPE)
Core colours according DINVDE0293-308
Core colours
- up to 5 cores one-coloured
- 6 and more cores, black with numbering
- 3 and above, with green-yellow earth core
- 2 cores without green-yellow earth core
Cores stranded in layers with optimal
lay-length
PUR outer sheath TMPU in adapted to
DINVDE0282 part10 appendixA
Jacket colour by request
with meter marking, change-over in 2009

Flame retardant according to


VDE0482-332-1-2, DIN EN60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Resistant to
Oils and fats
Water and weathering effects
Ozone and oxygen
UV-radiation
Hydrolysis, Microbial attack
Abrasion resistant
Notch resistant
Resistant to tearing and cutting
Good flexibility at low temperatures down
to -40C
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OB).
Colour code:
0 = RAL 5015, blue
1 = RAL 6018, green
2 = RAL 8003, brown
3 = RAL 1021, yellow
4 = RAL 3000, red
5 = RAL 2003, orange
6 = RAL 4005, violet
7 = RAL 7001/7032, grey
Please add the individual part no. for order
with the identification colour code.
Further colours on request.
screened analogue type:
UNIPUR-CP, seepageA58

Application
These robust and flexible cables are used for electrical tools such as drills, hand-held circular saws, and garden equipment as well as for
portable motors and machinery in agriculture, at building sites, for hobbies, docks and refrigeration plants.
Extremely good mechanical characteristies e.g. compressive load, good abrasion and near-resistant.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
1812_
1813_
1814_
1815_
1816_
1817_
1818_
1819_
1820_
1821_

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
34G0,5
41G0,5

Outer
app. mm
6,0
6,2
7,0
7,5
9,2
11,5
13,2
15,9
18,8
20,2

Cop.
weight
kg / km
9,6
14,4
19,0
24,0
33,6
58,0
86,0
120,0
163,0
197,0

Weight
app.
kg / km
40,0
47,0
57,0
65,0
94,0
150,0
208,0
276,0
393,0
460,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

A 49

20
20
20
20
20
20
20
20
20
20

Part No.
1822_
1823_
1824_
1825_
1826_
1827_
1828_
1829_
1830_
1831_
1832_

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
12G0,75
18G0,75
25G0,75
34G0,75
41G0,75

Outer
app. mm
6,3
6,9
7,5
8,3
9,0
9,8
12,2
14,1
17,5
20,3
21,9

Cop.
weight
kg / km
14,0
21,6
28,8
36,0
43,0
50,0
86,0
130,0
180,0
245,0
296,0

Weight
app.
kg / km
52,0
62,0
80,0
94,0
111,0
160,0
191,0
267,0
376,0
506,0
596,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
Continuation

Masters: 1812_ - ProductGroupID: PG2001 - Layout: L109_1 - Umbruch:

UNIPUR flexible at low temperature, with customer markings, halogen-free,


wear resistant, robust, meter marking
Part No.
1833_
1834_
1835_
1836_
1837_
1838_
1839_
1840_
1841_
1842_
1843_

1844_
1845_
1846_
1847_
1848_
1849_
1850_
1851_
1852_
1853_
1854_

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
6G1
7G1
12G1
18G1
25G1
34G1
41G1

2x1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
12G1,5
18G1,5
25G1,5
34G1,5
41G1,5

Outer
app. mm
6,8
7,2
7,8
8,8
9,6
10,5
13,0
15,1
18,7
21,6
23,2

8,3
8,8
9,9
10,8
11,9
12,9
14,7
17,9
20,8
24,9
26,7

Cop.
weight
kg / km
19,2
29,0
38,0
48,0
58,0
67,0
115,0
173,0
240,0
326,0
394,0

29,0
43,0
58,0
72,0
86,0
101,0
173,0
259,0
360,0
490,0
590,0

Weight
app.
kg / km
59,0
70,0
87,0
100,0
131,0
182,0
230,0
325,0
476,0
616,0
724,0

92,0
108,0
144,0
168,0
201,0
230,0
306,0
464,0
641,0
857,0
1010,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16

Part No.
1855_
1856_
1857_
1858_
1859_
1860_

1861_
1862_
1863_
1864_
1865_

1866_
1867_
1868_
1869_
1870_

1871_
1872_
1873_

1874_
1875_
1876_

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5

2x4
3G4
4G4
5G4
7G4

2x6
3G6
4G6
5G6
7G6

3G10
4G10
5G10

3G16
4G16
5G16

Outer
app. mm
10,0
10,5
11,8
13,0
14,7
18,0

11,6
12,3
13,7
15,2
20,8

13,2
14,2
15,8
17,5
22,0

18,6
20,5
22,7

23,5
25,7
28,5

Cop.
weight
kg / km
48,0
72,0
96,0
120,0
168,0
288,0

77,0
115,0
154,0
192,0
268,0

115,0
173,0
230,0
288,0
403,0

288,0
384,0
480,0

461,0
614,0
768,0

Weight
app.
kg / km
120,0
148,0
184,0
224,0
301,0
489,0

149,0
240,0
297,0
360,0
540,0

240,0
370,0
472,0
581,0
698,0

560,0
718,0
896,0

940,0
1068,0
1810,0

AWG-No.
14
14
14
14
14
14

12
12
12
12
12

10
10
10
10
10

8
8
8

6
6
6

Dimensions and specifications may be changed without prior notice. (RA02)

A 50

Masters: 49700 - ProductGroupID: PG2001 - Layout: L100_1 - Umbruch:

PUR-750

halogen-free, meter marking

Technical data

Cable structure

Properties

Special PUR cablesin adapted to


DINVDE0282 part10
Temperature range
flexing
-40C to +80C
(up to +100C for short periods)
Nominal voltage
U0/U 300/500 V up to 1 mm
U0/U 450/750 V as of 1,5 mm
Test voltage
2000 V up to 1 mm
2500 V as of 1,5 mm
Insulation resistance
min. 20 MOhm x km
Tensile strength 20 N/mm (Cu)
Minimum bending radius
flexing 10xcable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
PUR core insulation
Colour coded to DINVDE0293-308 and as
of 6 cores number coded
For two cores: brown, blue
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
PUR outer jacket halogen-free
Sheath colour orange (RAL 2004)
with meter marking, change-over in 2009

High flexibility at low temperature


Usable for foodstuffs
High abrasion resistance
Resistant to
Oils and fats
Non-alcoholic fuels and kerosene
Atmospheric influences, UV-radiation
Oxygene and ozone
Microbes and rotting
Sea and waste water, vibrations
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Especially suited for installation in all areas demanding good performance under extreme conditions. These cable types have been successfully
in use in areas such as steel works, heating and air-conditioning systems, in machinery and industrial plant equipment and on building sites
etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
49700
49701
49702
49703
49704
49705
49706
49707

49708
49709
49710
49711
49712
49713
49714
49715
49716
49717
49718
49719
49720

49721
49722
49723
49724
49725
49726
49727
49728
49729
49730
49731

49732
49733
49734
49735

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75

2x1
3G1
4G1
5G1
6G1
7G1
8G1
10G1
12G1
16G1
18G1
20G1
25G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
10G1,5
12G1,5
16G1,5
18G1,5
20G1,5
25G1,5

2x2,5
3G2,5
4G2,5
5G2,5

Outer
app. mm
6,3
6,8
7,4
8,3
9,7
12,1
14,2
17,8

6,8
7,2
7,8
8,7
9,5
10,2
11,2
12,6
12,8
14,3
15,3
16,2
18,8

8,2
8,7
9,7
10,6
12,8
15,5
15,8
17,9
19,0
20,0
23,5

9,8
10,5
11,6
13,0

Cop.
weight
kg / km
15,0
22,0
29,0
36,0
50,0
86,0
130,0
180,0

20,0
29,0
38,0
48,0
58,0
67,0
77,0
96,0
115,0
154,0
173,0
192,0
240,0

29,0
43,0
58,0
72,0
101,0
150,0
172,0
230,0
259,0
300,0
360,0

48,0
72,0
96,0
120,0

Weight
app.
kg / km
44,0
55,0
70,0
91,0
130,0
192,0
290,0
405,0

50,0
65,0
87,0
106,0
135,0
160,0
185,0
210,0
240,0
310,0
353,0
390,0
495,0

70,0
95,0
120,0
164,0
210,0
290,0
340,0
440,0
508,0
560,0
722,0

110,0
150,0
180,0
240,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

A 51

18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16

14
14
14
14

Part No.
49736
49737
49738
49739
49740
49741

49742
49743
49744
49745

49746
49747
49748

49749
49750
49751

49752
49753

49754
49755

49756
49757

49758
49759

49760
49761

49918
49762

49763

No.cores x
cross-sec.
mm
7G2,5
12G2,5
16G2,5
18G2,5
20G2,5
25G2,5

3G4
4G4
5G4
7G4

4G6
5G6
7G6

4G10
5G10
7G10

4G16
5G16

4G25
5G25

4G35
5G35

4G50
5G50

4G70
5G70

4G95
5G95

4G120

Outer
app. mm
15,5
19,3
21,6
23,0
24,4
28,5

12,2
13,4
15,1
18,2

15,8
17,5
21,0

20,6
22,7
26,6

23,6
26,2

29,4
32,7

33,1
36,8

38,4
43,0

44,0
49,5

51,2
57,5

55,0

Cop.
weight
kg / km
168,0
288,0
394,0
432,0
480,0
600,0

115,0
154,0
192,0
269,0

230,0
288,0
403,0

384,0
480,0
672,0

614,0
768,0

960,0
1200,0

1344,0
1680,0

1920,0
2400,0

2688,0
3660,0

3648,0
4560,0

4610,0

Weight
app.
kg / km
340,0
520,0
680,0
778,0
860,0
1083,0

220,0
280,0
350,0
470,0

400,0
500,0
700,0

640,0
800,0
1180,0

920,0
1180,0

1400,0
1740,0

1870,0
2320,0

2700,0
3300,0

3700,0
4900,0

4850,0
6000,0

6005,0

AWG-No.
14
14
14
14
14
14

12
12
12
12

10
10
10

8
8
8

6
6

4
4

2
2

1
1

2/0
2/0

3/0
3/0

4/0

Masters: 23414 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

JZ 500-FC-PUR

EMC-preferred type, tear and coolant resistant,

screened, without inner sheath, meter marking

Technical data

Cable structure

Special polyurethane sheathed cable


adapted to DINVDE0245 part201 to
1,5mm,
adapted to DINVDE0245 part102 from
2,5mm
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage
min. 6000 V
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper conductor, fine wire to


DINVDE0295 cl.5, BS6360 cl.5 and/or
IEC60228 cl.5
Core insulation of special PVCTI2 to
DINVDE0281, part1
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Separating foil
Tinned copper braided screening, coverage
approx. 85%
Core wrapping from fleece guarantees
good stripping capability
Outer sheath from special full
polyurethane TMPU acc. to DINVDE0282
part10, appendixA
Sheath colour grey (RAL 7001)
Also available in other sheath colours
with meter marking, change-over in 2009

Properties

Resistant to
UV-radiation
Oxygen
Ozone
Hydrolyse
Microbes
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
unscreened analogue type:
JZ-500-PUR, seepageA43

Application
Extremely robust cable noted for its good abrasion resistance and notch resistance. Due to its resistance to coolant emulsions, this cable
is well suited for use in mechanical engineering, tool making, and systems engineering, and in steel mills and rolling mills in particularly
critical areas. Good flexibility means that installation is quick and easy. Suitable for medium mechanical stresses with free movement without
tensile stress or forced movements in dry, moist and wet rooms, and in open air (fixed installation). The dense screening assures
interference-free transmission of all signals and impulses. An ideal interference-free control cable for the above applications.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
23414
23416
23415
23417
23418
23420
23419
23421
23422
23423
23424
23425
23426
23427
23428

No.cores x
cross-sec.
mm
2x0,5
3x0,5
3G0,5
4G0,5
4x0,5
5x0,5
5G0,5
7G0,5
7x0,5
10G0,5
12G0,5
18G0,5
25G0,5
34G0,5
42G0,5

Outer
app. mm
5,3
5,6
5,6
6,2
6,2
6,5
6,5
7,5
7,5
9,0
9,2
10,9
13,3
15,0
16,2

Cop.
weight
kg / km
35,0
42,0
42,0
47,0
47,0
56,0
56,0
69,0
69,0
94,0
108,0
145,0
240,0
312,0
355,0

Weight
app.
kg / km
47,0
57,0
57,0
60,0
60,0
75,0
75,0
97,0
97,0
133,0
158,0
218,0
315,0
420,0
487,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Part No.
23429
23431
23430
23432
23433
23435
23434
23436
23437
23438
23439
23440
23441
23442
23443

No.cores x
cross-sec.
mm
2x0,75
3x0,75
3G0,75
4G0,75
4x0,75
5x0,75
5G0,75
7G0,75
7x0,75
10G0,75
12G0,75
18G0,75
25G0,75
34G0,75
42G0,75

Outer
app. mm
5,8
6,1
6,1
6,5
6,5
7,1
7,1
8,3
8,3
10,1
10,3
12,1
14,9
16,6
17,9

Cop.
weight
kg / km
40,0
52,0
52,0
60,0
60,0
71,0
71,0
91,0
91,0
137,0
142,0
212,0
281,0
345,0
407,0

Weight
app.
kg / km
60,0
67,0
67,0
76,0
76,0
92,0
92,0
131,0
131,0
180,0
204,0
290,0
413,0
492,0
624,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
Continuation

A 52

Masters: 23414 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

JZ 500-FC-PUR

EMC-preferred type, tear and coolant resistant,

screened, without inner sheath, meter marking


Part No.
23444
23445
23446
23448
23447
23450
23449
23452
23451
23453
23454
23455
23456
23457
23458
23459

23460
23462
23461
23464
23463
23466
23465
23468
23467
23469
23470
23471
23472

No.cores x
cross-sec.
mm
2x1
3G1
3x1
4x1
4G1
5x1
5G1
7x1
7G1
10G1
12G1
18G1
25G1
34G1
42G1
50G1

2x1,5
3x1,5
3G1,5
4x1,5
4G1,5
5x1,5
5G1,5
7x1,5
7G1,5
12G1,5
18G1,5
25G1,5
30G1,5

Outer
app. mm
6,1
6,3
6,3
6,9
6,9
7,5
7,5
8,9
8,9
10,7
10,9
13,0
15,9
17,9
19,3
21,2

6,6
6,9
6,9
7,5
7,5
8,4
8,4
10,0
10,0
12,1
14,6
17,9
18,2

Cop.
weight
kg / km
50,0
60,0
60,0
71,0
71,0
88,0
88,0
111,0
111,0
150,0
184,0
260,0
349,0
486,0
545,0
625,0

63,0
80,0
80,0
97,0
97,0
119,0
119,0
147,0
147,0
267,0
374,0
526,0
555,0

Weight
app.
kg / km
66,0
82,0
82,0
100,0
100,0
128,0
128,0
157,0
157,0
230,0
262,0
381,0
535,0
740,0
867,0
1027,0

87,0
102,0
102,0
127,0
127,0
159,0
159,0
207,0
207,0
340,0
480,0
704,0
817,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

A 53

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16

Part No.
23473
23474
23475
23476
23477
23478

23479
23480
23481

23482
23483
23484

23485
23486
23487

23488

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5

4G4
5G4
7G4

4G6
5G6
7G6

4G10
5G10
7G10

4G16

Outer
app. mm
8,2
8,6
9,6
10,6
12,6
15,5

11,0
12,3
13,6

13,3
14,9
16,3

17,8
19,6
21,6

20,8

Cop.
weight
kg / km
96,0
144,0
148,0
181,0
255,0
441,0

230,0
273,0
316,0

305,0
439,0
505,0

535,0
592,0
810,0

740,0

Weight
app.
kg / km
131,0
168,0
194,0
222,0
345,0
570,0

310,0
386,0
498,0

414,0
510,0
673,0

591,0
768,0
976,0

1196,0

AWG-No.
14
14
14
14
14
14

12
12
12

10
10
10

8
8
8

6

Masters: 21200 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

F-C-PUR-JZ

tear and coolant resistant, Cu-screened, without inner sheath,

increased oil resistant, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special polyurethane-sheathed multicore


cable on the basis of EDINVDE0245
part201 up to 1,5mm, on the basis of
EDINVDE0245 part102 as of 2,5mm
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Plain copper conductor, finely stranded,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Oil resistant PVC core insulation TI2, in
adapted to DINVDE0281 part1, for better
sliding abilities
Cores black with sequential numbering
imprinted in white according to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Separating foil
Braided screen of tinned Cu wires, coverage
approx. 85%
Fleece separator, ensure good dismantling
ability
Special full-polyurethane outer jacket
TMPU, to DINVDE0282 part10, appendixA
Sheath colour grey (RAL 7001)
Outer jacket also available in other colours
with meter marking, change-over in 2009

Resistant to
UV-Radiation
Oxygene
Ozone and hydrolysis
Microbes
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
PUR-JZ, seepageA44

Application
Extremely robust control cable characterised by high abrasion and notch resistance properties. Used for critical areas in such applications
as machinery, tooling and plant construction, in rolling mills and steel works because of the resistance to mineral oils and to coolant emulsions
in particular. Rapid and safe installation assured by the good flexibility of the cable. Suitable for outdoor installation.
An interference-free transmission of signals and pulses is assured by the high screening density. The ideal interference-protected control
cable for such applications as given above.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
21200
21201
21202
21203
21205
21207
21208
21209
21211
21213
21215
21217
21220
21221
21224

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
21G0,5
25G0,5
30G0,5
36G0,5
40G0,5
50G0,5

Outer
app. mm
5,3
5,6
6,2
6,5
7,5
9,0
9,2
9,9
10,9
12,1
13,3
13,7
15,0
16,2
17,8

Cop.
weight
kg / km
35,0
42,0
47,0
56,0
69,0
94,0
108,0
116,0
145,0
188,0
240,0
295,0
318,0
343,0
406,0

Weight
app.
kg / km
44,0
56,0
60,0
75,0
97,0
133,0
158,0
190,0
218,0
252,0
315,0
362,0
447,0
475,0
572,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Part No.
21227
21228
21229
21230
21232
21234
21235
21236
21238
21240
21242
21245
21249
21251

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
18G0,75
21G0,75
25G0,75
32G0,75
41G0,75
50G0,75

Outer
app. mm
5,8
6,1
6,5
7,1
8,3
10,1
10,3
10,7
12,1
13,4
14,9
16,0
17,9
19,7

Cop.
weight
kg / km
40,0
52,0
60,0
71,0
91,0
137,0
142,0
180,0
212,0
246,0
281,0
342,0
400,0
461,0

Weight
app.
kg / km
60,0
67,0
76,0
92,0
131,0
180,0
204,0
226,0
290,0
376,0
413,0
485,0
611,0
775,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
Continuation

A 54

Masters: 21200 - ProductGroupID: PG1501 - Layout: L101_1 - Umbruch:

F-C-PUR-JZ

tear and coolant resistant, Cu-screened, without inner sheath,

increased oil resistant, EMC-preferred type, meter marking


Part No.
21253
21254
21255
21256
21257
21258
21259
21261
21262
21263
21264
21265
21267
21268
21273
21276
21278

21280
21281
21282
21283
21285
21286
21287
21288

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
6G1
7G1
8G1
10G1
12G1
14G1
16G1
18G1
21G1
25G1
34G1
41G1
50G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5

Outer
app. mm
6,1
6,3
6,9
7,5
8,3
8,9
9,6
10,7
10,9
11,6
12,2
13,0
13,6
15,9
17,9
19,3
21,2

6,6
6,9
7,5
8,4
10,0
10,7
11,8
12,1

Cop.
weight
kg / km
50,0
60,0
71,0
88,0
97,0
111,0
127,0
150,0
184,0
196,0
209,0
260,0
319,0
349,0
486,0
531,0
625,0

63,0
80,0
97,0
119,0
147,0
170,0
193,0
267,0

Weight
app.
kg / km
66,0
82,0
100,0
128,0
145,0
157,0
198,0
230,0
262,0
302,0
345,0
381,0
480,0
535,0
740,0
855,0
1027,0

87,0
102,0
127,0
159,0
207,0
245,0
313,0
340,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

A 55

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16

Part No.
21290
21291
21292
21295
21296
21297
21298
21299

21300
21301
21302
21303
21304
21305
21306

21313
21314
21315
21316
21317

21319
21320
21321
21322

No.cores x
cross-sec.
mm
14G1,5
16G1,5
18G1,5
21G1,5
25G1,5
34G1,5
42G1,5
50G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
10G2,5
12G2,5

2x4
3G4
4G4
5G4
7G4

3G6
4G6
5G6
7G6

Outer
app. mm
12,9
13,6
14,6
16,2
17,9
20,0
21,8
23,6

8,2
8,6
9,6
10,6
12,6
15,1
15,5

10,0
10,5
11,7
13,3
14,5

12,2
13,6
15,2
15,4

Cop.
weight
kg / km
283,0
315,0
374,0
425,0
526,0
629,0
819,0
885,0

96,0
144,0
148,0
181,0
255,0
340,0
441,0

120,0
174,0
230,0
273,0
316,0

240,0
305,0
439,0
505,0

Weight
app.
kg / km
384,0
425,0
480,0
563,0
704,0
870,0
1040,0
1292,0

131,0
168,0
194,0
222,0
345,0
462,0
570,0

187,0
243,0
310,0
386,0
498,0

333,0
414,0
510,0
673,0

AWG-No.
16
16
16
16
16
16
16
16

14
14
14
14
14
14
14

12
12
12
12
12

10
10
10
10

Masters: 21400 - ProductGroupID: PG1501 - Layout: L101-14_1 - Umbruch:

Y-C-PUR-JZ

tear and coolant resistant, Cu-screened,

with inner sheath, increased oil resistant, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special polyurethane-sheathed multicore


cable on the basis of EDINVDE0245
part202/03.92 up to1,5 mm, on the basis
of EDINVDE0281 part13 as of 2,5mm
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
as of cross section 4 mm
U0/U 450/750 V
Test voltage 4000 V
Breakdown voltage min. 8000 V
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Plain copper conductor, finely stranded,


according to DINVDE0295 cl.5, BS6360
cl.5 and IEC60228 cl.5
Oil resistant PVC core insulation TI2, in
adapted to DINVDE0281 part1, for better
sliding abilities
Cores black with sequential numbering
imprinted in white according to
DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Oil resistant PVC inner sheath
Sceen of tinned Cu braid, coverage approx.
85%
Fleece separator, ensure good dismantling
ability
Special full-polyurethane outer jacket
TMPU, to DINVDE0282 part10, appendixA
Sheath colour grey (RAL7001)
with meter marking, change-over in 2009

Resistant to
UV-Radiation
Oxygene
Ozone and hydrolysis
Microbes
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
PUR-JZ, seepageA44

Application
Extremely robust control cable characterised by high abrasion and notch resistance properties. Used for critical areas in such applications
as machinery, tooling and plant construction, in rolling mills and steel works because of the resistance to mineral oils and to coolant emulsions
in particular. The mechanical strength of the cable is increased by the additional oil-resistant inner sheath. The ideal interference-protected
control cable for such applications as given above. Suitable for outdoor installation.
These screened cables are particularly suitable for the interference-free transmission in instrumentation and control engineering applications
(electromagnetic compatibility).
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
21400
21401
21402
21403
21405
21407
21408
21409
21411
21413
21415
21416
21419
21420
21421

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
21G0,5
25G0,5
30G0,5
36G0,5
40G0,5
50G0,5

Outer
app. mm
6,6
7,1
7,6
8,2
9,4
11,2
11,3
11,9
12,9
14,7
15,9
16,2
17,8
19,1
20,9

Cop.
weight
kg / km
41,0
45,0
54,0
66,0
79,0
107,0
137,0
142,0
156,0
189,0
250,0
297,0
320,0
345,0
407,0

Weight
app.
kg / km
68,0
84,0
95,0
107,0
135,0
170,0
195,0
222,0
278,0
330,0
406,0
520,0
587,0
655,0
742,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

Part No.
21425
21426
21427
21428
21430
21432
21433
21434
21436
21438
21440
21443
21446
21447

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
18G0,75
21G0,75
25G0,75
32G0,75
41G0,75
50G0,75

Outer
app. mm
7,2
7,7
8,2
8,8
10,1
12,2
12,3
13,0
14,6
16,0
17,8
18,7
21,5
23,1

Cop.
weight
kg / km
46,0
57,0
63,0
76,0
100,0
140,0
175,0
190,0
240,0
274,0
306,0
349,0
403,0
470,0

Weight
app.
kg / km
88,0
98,0
112,0
130,0
185,0
270,0
294,0
317,0
357,0
455,0
510,0
688,0
951,0
1100,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
Continuation

A 56

Masters: 21400 - ProductGroupID: PG1501 - Layout: L101-14_1 - Umbruch:

Y-C-PUR-JZ

tear and coolant resistant, Cu-screened,

with inner sheath, increased oil resistant, EMC-preferred type, meter marking
Part No.
21451
21452
21453
21454
21456
21457
21458
21459
21460
21461
21462
21463
21465
21468
21469
21470

21474
21475
21476
21477
21479
21480
21481
21482
21483
21484
21485
21487
21489
21492
21494
21495

21499
21500
21501
21502
21503
21504

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
8G1
10G1
12G1
14G1
16G1
18G1
20G1
25G1
34G1
41G1
50G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
14G1,5
16G1,5
18G1,5
21G1,5
25G1,5
34G1,5
42G1,5
50G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5

Outer
app. mm
7,7
8,0
8,6
9,1
11,0
12,6
12,6
13,1
13,8
14,6
15,6
16,4
18,9
20,9
22,3
24,6

8,2
8,6
9,3
10,4
12,0
12,9
14,2
14,6
15,4
16,1
17,2
19,0
20,8
23,2
26,1
27,4

9,8
10,7
11,4
12,5
14,9
18,4

Cop.
weight
kg / km
54,0
64,0
76,0
89,0
114,0
130,0
156,0
186,0
198,0
214,0
284,0
325,0
387,0
500,0
578,0
681,0

64,0
82,0
99,0
123,0
148,0
172,0
198,0
274,0
294,0
318,0
386,0
447,0
531,0
671,0
890,0
997,0

110,0
148,0
169,0
220,0
284,0
470,0

Weight
app.
kg / km
98,0
102,0
145,0
170,0
220,0
270,0
330,0
350,0
402,0
420,0
515,0
545,0
690,0
912,0
1070,0
1318,0

130,0
152,0
167,0
203,0
305,0
335,0
422,0
435,0
480,0
525,0
642,0
722,0
803,0
1068,0
1370,0
1677,0

180,0
215,0
268,0
349,0
406,0
720,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

A 57

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

14
14
14
14
14
14

Part No.
21507
21508
21509
21510
21511

21512
21513
21514
21515

21516
21517
21518
21519

21521
21522

21524
21525

21526
21527

21528
21529

21530
21531

21532
21533

21534

No.cores x
cross-sec.
mm
2x4
3G4
4G4
5G4
7G4

3G6
4G6
5G6
7G6

3G10
4G10
5G10
7G10

4G16
5G16

4G25
5G25

4G35
5G35

4G50
5G50

4G70
5G70

4G95
5G95

4G120

Outer
app. mm
12,0
12,6
14,2
15,6
17,1

14,8
16,1
18,0
19,6

18,2
20,3
22,4
24,7

23,4
26,0

29,7
33,0

33,9
37,5

39,0
43,4

46,6
51,1

50,9
55,9

55,5

Cop.
weight
kg / km
124,0
178,0
234,0
284,0
321,0

245,0
316,0
442,0
530,0

367,0
549,0
604,0
820,0

807,0
940,0

1169,0
1420,0

1680,0
2020,0

2370,0
2880,0

3257,0
4032,0

4060,0
5244,0

5231,0

Weight
app.
kg / km
300,0
340,0
408,0
504,0
640,0

453,0
560,0
700,0
905,0

750,0
1023,0
1114,0
1505,0

1385,0
1550,0

1894,0
2272,0

2395,0
2890,0

3312,0
4100,0

4605,0
5710,0

6055,0
7520,0

7318,0

AWG-No.
12
12
12
12
12

10
10
10
10

8
8
8
8

6
6

4
4

2
2

1
1

2/0
2/0

3/0
3/0

4/0

Masters: 1915_ - ProductGroupID: PG2001 - Layout: L109_1 - Umbruch:

UNIPUR-CP flexible at low temperature, with customer markings, halogen-free,


wear resistant, robust, screened, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Special TPE/PUR screened connecting cable


adapted to DINVDE0282 part10
Temperature range
flexing-40C to +90C
Nominal voltage
up to 1 mm U0/U 300/500 V
above 1,5 mm U0/U 450/750 V
Test voltage 3000 V
Minimum bending radius
flexing 12,5x cable
fixed installation 7,5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors bunch


stranded according to DINVDE0295 cl.5,
BS6360 cl.5 and IEC60228 cl.5
Core insulation of termoplastic elastomere
(TPE)
Core colours according DINVDE0293-308
- up to 5 cores one-coloured
- 6 and more cores, black with numbering
- 3 and above, with green-yellow earth core
- 2 cores without green-yellow earth core
Cores stranded in layers with optimal
lay-length
Core wrapping with foil
PUR outer sheath TMPU in adapted to
DINVDE0282 part10 appendixA
Jacket colour by request
We can also have this cable with your
company name or emblem. Minimum
quantity 500-1000 m.
with meter marking, change-over in 2009

Flame retardant according to


VDE0482-332-1-2, DIN EN60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Resistant to
Oils and fats
Water and weathering effects
Ozone and oxygen
UV-radiation
Hydrolysis
Microbial attack
Abrasion resistant
Notch resistant
Resistant to tearing and cutting
Good flexibility at low temperatures down
to -40C
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OB).
Colour code:
0 = RAL 5015, blue
1 = RAL 6018, green
2 = RAL 8003, brown
3 = RAL 1021, yellow
4 = RAL 3000, red
5 = RAL 2003, orange
6 = RAL 4005, violet
7 = RAL 7001/7032, grey
Please add the individual part no. for order
with the identification colour code.
Further colours on request.
unscreened analogue type:
UNIPUR, seepageA49

Application
These robust and flexible cables are used for electrical tools such as drills, hand-held circular saws, and garden equipment as well as for
portable motors and machinery in agriculture, at building sites, for hobbies, docks and refrigeration plants.
Extremely good mechanical characteristies e.g. compressive load, good abrasion and near-resistant.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
1915_
1916_
1917_
1918_
1919_
1920_
1921_
1922_
1923_
1924_

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5
34G0,5
41G0,5

Outer
app. mm
6,1
6,3
6,8
7,4
8,8
10,9
13,0
15,6
17,2
19,4

Cop.
weight
kg / km
35,0
42,0
47,0
56,0
69,0
108,0
145,0
240,0
312,0
348,0

Weight
app.
kg / km
46,0
56,0
62,0
75,0
98,0
158,0
216,0
315,0
371,0
442,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

20
20
20
20
20
20
20
20
20
20

Part No.
1925_
1926_
1927_
1928_
1929_
1930_
1931_
1932_
1933_
1934_
1935_

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75
7G0,75
12G0,75
18G0,75
25G0,75
34G0,75
41G0,75

Outer
app. mm
6,8
7,1
7,7
8,4
9,1
10,0
12,3
14,8
18,4
20,3
22,0

Cop.
weight
kg / km
40,0
52,0
60,0
71,0
80,0
91,0
142,0
212,0
281,0
345,0
400,0

Weight
app.
kg / km
60,0
68,0
78,0
95,0
112,0
138,0
207,0
293,0
413,0
523,0
609,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
Continuation

A 58

Masters: 1915_ - ProductGroupID: PG2001 - Layout: L109_1 - Umbruch:

UNIPUR-CP flexible at low temperature, with customer markings, halogen-free,


wear resistant, robust, screened, EMC-preferred type, meter marking
Part No.
1936_
1937_
1938_
1939_
1940_
1941_
1942_
1943_
1944_
1945_
1946_

1947_
1948_
1949_
1950_
1951_
1952_
1953_
1954_
1955_
1956_
1957_

No.cores x
cross-sec.
mm
2G1
3G1
4G1
5G1
6G1
7G1
12G1
18G1
25G1
34G1
41G1

2G1,5
3G1,5
4G1,5
5G1,5
6G1,5
7G1,5
12G1,5
18G1,5
25G1,5
34G1,5
41G1,5

Outer
app. mm
7,1
7,4
8,1
8,8
9,7
10,7
12,9
15,7
19,3
21,6
23,3

8,4
8,8
9,8
10,9
12,1
13,2
16,5
19,6
24,2
27,0
29,3

Cop.
weight
kg / km
50,0
60,0
71,0
88,0
97,0
111,0
184,0
260,0
349,0
486,0
531,0

63,0
80,0
97,0
119,0
121,0
147,0
267,0
374,0
526,0
629,0
801,0

Weight
app.
kg / km
65,0
76,0
89,0
108,0
141,0
187,0
240,0
335,0
484,0
627,0
738,0

97,0
119,0
152,0
168,0
218,0
243,0
317,0
481,0
674,0
881,0
1027,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA02)

A 59

17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16

Part No.
1958_
1959_
1960_
1961_
1962_
1963_

1964_
1965_
1966_
1967_
1968_

1969_
1970_
1971_
1972_
1973_

1974_
1975_
1976_

1977_
1978_
1979_

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5

2x4
3G4
4G4
5G4
7G4

2x6
3G6
4G6
5G6
7G6

3G10
4G10
5G10

3G16
4G16
5G16

Outer
app. mm
10,0
10,7
11,9
13,2
16,0
19,8

11,8
12,4
13,8
15,6
18,9

13,4
14,3
16,0
17,9
21,6

18,1
20,2
22,5

20,6
23,0
25,6

Cop.
weight
kg / km
96,0
144,0
148,0
181,0
255,0
441,0

120,0
174,0
230,0
273,0
316,0

173,0
240,0
305,0
439,0
505,0

350,0
535,0
592,0

585,0
740,0
895,0

Weight
app.
kg / km
129,0
158,0
196,0
241,0
317,0
496,0

158,0
261,0
316,0
384,0
592,0

259,0
394,0
483,0
592,0
714,0

576,0
729,0
914,0

960,0
1813,0
1827,0

AWG-No.
14
14
14
14
14
14

12
12
12
12
12

10
10
10
10
10

8
8
8

6
6
6

Masters: 22315 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

PUR-C-PUR Cu-screened, extrem conditions, halogen-free, EMC-preferred type, meter


marking

Technical data

Cable structure

Properties

Special PUR control cables, screened,


adapted to DINVDE0250
Temperature range
-40C to +80C
Nominal voltage
U0/U 300/500 V until 1 mm
U0/U 450/750 V from 1,5 mm
Test voltage
until 1 mm 2000 V
from 1,5 mm 2500 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance (800 Hz)
core/core approx. 150 pF/m
core/screen approx. 320 pF/m
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Special PUR insulation
Core identification according to
DINVDE0293-308
Green-yellow earth core (3 cores and above)
Cores stranded in layers with optimal
lay-length
Foil taped
Copper braided screening with 80-85%
coverage
PUR outer jacket
Colour grey (RAL7032)
with meter marking, change-over in 2009

High flexibility at low temperatures


High abrasion resistance
Break and cut resistant
Tear resistant
Resistant to
Oils and fats
Coolant and chemicals
Non-alcoholic fuels and kerosene
Atmospheric influences
UV-radiation
Oxygene and ozone
Microbes and rotting
Sea and waste water
Vibrations
Acids and Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (O).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
PUR-C-PUR screened cables are well suited as data transfer and connection cables for the machine and motor industries due to the good
level of copper screening which blocks strong electrical disturbances.
This cable type has proven to be especially suited to use in extreme weather and environmental conditions due to its good thermal and
chemical properties. (Temperature range -40C to +80C). In addition to this it also possesses excellent mechanical properties, e.g. pressure
resistance and good abrasive resistant qualities, all of which go to guarantee a long life.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
22315
22316
22317
22318
22319

22339
22340
22341
22342

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75
6G0,75

2x1
3G1
4G1
5G1

Outer
app. mm
6,7
7,2
7,7
9,1
9,5

7,5
7,7
8,4
9,5

Cop.
weight
kg / km
40,0
52,0
60,0
71,0
80,0

50,0
60,0
71,0
88,0

Weight
app.
kg / km
65,0
80,0
95,0
126,0
150,0

80,0
95,0
106,0
149,0

AWG-No.
18
18
18
18
18

17
17
17
17

Part No.
22364
22365
22366
22367

22385
22386
22387
22388

No.cores x
cross-sec.
mm
2x1,5
3G1,5
4G1,5
5G1,5

2x2,5
3G2,5
4G2,5
5G2,5

Outer
app. mm
8,8
9,0
9,6
11,0

10,1
10,3
11,8
12,7

Cop.
weight
kg / km
63,0
80,0
97,0
119,0

96,0
144,0
148,0
181,0

Weight
app.
kg / km
101,0
125,0
150,0
210,0

142,0
169,0
225,0
275,0

AWG-No.
16
16
16
16

14
14
14
14

Dimensions and specifications may be changed without prior notice. (RA02)

A 60

JZ-500 HMH
MEGAFLEX 500
JZ-600 HMH
JB-500 HMH
(H)03 Z1Z1-F
(H)05 Z1Z1-F
JZ-500 HMH-C
MEGAFLEX 500-C
JZ-600 HMH-C
JB-500 HMH-C
Photo: HELUKABEL

Halogen-free Control Cables


In all locations, due to damages of large amount
of materials and more of importance to protect
human life and technical equipment against
damages caused by re and also for technical
enquiries of insurance, the installation of
halogen-free security cables are required.
You will nd on the following pages the
instructions for installation as well as the test
methods and laying instructions for the halogenfree security cables.

The most important advantages:


No re propagation from point of re
Functionallity for important systems
No corrosion and damage caused by released
corrosive gases and vapours
Protection of human life and valuable materials,
especially for high quality machines, EDP
systems etc.
Prevention of heavy and unexpected
subsequent damages
Low smoke density helps rescue and re
extinguishing

A 61

31472-00e-A061.indd 90

03.04.2009 7:39:05 Uhr

Masters: 11201 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

JZ-500 HMH flexible control cable, halogen-free, extremely fire resistant,


oil resistant1), meter marking

Technical data

Cable structure

Properties

Halogen-free flexible control cable, adapted


to EDINVDE0281 part14 and DINVDE0281
part13
Temperature range
flexing -15C to +70C
fixed installation -40C to +70C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Minimum bending radius
flexing approx. 12,5x cable
fixed installation approx. 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free compound
TI6, to EDINVDE0281 part14
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layer with optimal
lay-length
Halogen-free sheath compound TM7, to
EDINVDE0281 part14
Outer jacket colour grey (RAL7001)
with meter marking, change-over in 2009
LS0H = Low Smoke Zero Halogen-free.

) For the critical applications we advise for


consultation
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test to VDE0482 part266-2, BS4066
part3/ DINEN50266-2/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
Please note the cleanroom qualification
when ordering.
screened analogue type:
JZ-500 HMH-C, seepageA71

Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as
in plant installations, in air-conditioning and steel production works. For fixed installation or flexible application, directed without forcing by
casual, not constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is suitable for the
application in dry, damp and wet environments and also for laying on, in and under plaster as well as in concrete and masonry excluding in
direct laying in shaked or stamped concrete, not suitable for imbedding in solidified or compressed concrete.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
11201
11202
11332
11203
11333
11204
11334
11205
11206
11207
11208
11209

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5
8G0,5
10G0,5
12G0,5
16G0,5

Outer
app. mm
4,8
5,1
5,1
5,7
5,7
6,2
6,2
7,4
8,0
8,8
9,1
10,0

Cop.
weight
kg / km
9,6
14,4
14,4
19,0
19,0
24,0
24,0
33,6
38,0
48,0
58,0
76,0

Weight
app.
kg / km
43,0
50,0
50,0
60,0
60,0
71,0
71,0
84,0
101,0
121,0
142,0
183,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA03)

20
20
20
20
20
20
20
20
20
20
20
20

Part No.
11210
11211
11212
11213
11214
11215
11216
11217
11218
11219
11220

No.cores x
cross-sec.
mm
18G0,5
20G0,5
25G0,5
30G0,5
34G0,5
37G0,5
41G0,5
42G0,5
50G0,5
61G0,5
65G0,5

Outer
app. mm
10,7
11,2
12,7
13,5
14,5
15,0
15,8
15,8
17,3
19,4
19,4

Cop.
weight
kg / km
86,0
96,0
120,0
144,0
163,0
178,0
197,0
202,0
240,0
293,0
312,0

Weight
app.
kg / km
204,0
227,0
283,0
324,0
367,0
381,0
417,0
454,0
519,0
635,0
694,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
Continuation

A 62

Masters: 11201 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

JZ-500 HMH flexible control cable, halogen-free, extremely fire resistant,


oil resistant1), meter marking
Part No.
11221
11222
11335
11223
11336
11224
11337
11225
11338
11226
11227
11228
11229
11230
11231
11232
11233
11234
11235
11236
11237
11238
11239
11240

11241
11242
11339
11243
11340
11244
11245
11246
11247
11248
11249
11250
11251
11252
11253
11254
11255
11256
11257
11258
11259

11260
11261
11341
11262
11263
11264
11265
11266
11267
11268
11269
11270
11271
11272
11273
11274
11275
11276

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
8G0,75
10G0,75
12G0,75
16G0,75
18G0,75
20G0,75
25G0,75
30G0,75
34G0,75
37G0,75
41G0,75
42G0,75
50G0,75
61G0,75
65G0,75

2x1
3G1
3x1
4G1
4x1
5G1
7G1
8G1
10G1
12G1
16G1
18G1
20G1
25G1
34G1
37G1
41G1
42G1
50G1
61G1
65G1

2x1,5
3G1,5
3x1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
16G1,5
18G1,5
20G1,5
25G1,5
34G1,5
37G1,5
50G1,5
61G1,5
65G1,5

Outer
app. mm
5,2
5,5
5,5
6,2
6,2
6,8
6,8
8,1
8,1
8,9
9,6
9,9
11,5
11,9
12,6
14,1
15,4
16,4
17,2
17,6
17,6
19,8
20,9
21,5

5,5
6,0
6,0
6,6
6,6
7,2
8,6
9,4
10,4
10,7
12,0
12,7
13,5
15,2
17,4
18,4
18,9
18,9
21,0
22,2
22,8

6,3
6,7
6,7
7,3
8,2
9,8
10,6
11,7
12,1
13,6
14,5
15,2
17,8
19,8
20,2
23,7
25,3
26,0

Cop.
weight
kg / km
14,4
21,6
21,6
29,0
29,0
36,0
36,0
50,0
50,0
58,0
72,0
86,0
115,0
130,0
144,0
180,0
216,0
245,0
260,0
296,0
302,0
360,0
439,0
468,0

19,2
29,0
29,0
38,4
38,4
48,0
67,0
77,0
96,0
115,0
154,0
173,0
192,0
240,0
326,0
355,0
394,0
403,0
480,0
586,0
628,0

29,0
43,0
43,0
58,0
72,0
101,0
115,0
144,0
173,0
230,0
259,0
288,0
360,0
490,0
533,0
720,0
878,0
936,0

Weight
app.
kg / km
47,0
56,0
56,0
69,0
69,0
83,0
83,0
114,0
114,0
136,0
172,0
183,0
241,0
266,0
291,0
374,0
450,0
517,0
541,0
611,0
621,0
742,0
853,0
909,0

63,0
74,0
74,0
90,0
90,0
109,0
151,0
184,0
224,0
243,0
314,0
361,0
387,0
496,0
670,0
713,0
784,0
824,0
952,0
1140,0
1201,0

70,0
94,0
94,0
112,0
141,0
191,0
224,0
282,0
311,0
392,0
450,0
497,0
630,0
842,0
897,0
1277,0
1460,0
1612,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA03)

A 63

18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Part No.
11277
11278
11279
11280
11281
11282
11283
11284
11285
11286
11287
11288
11289

11290
11291
11292
11293
11294
11295
11296
11297
11298
11299

11300
11301
11302
11303
11304

11305
11306
11307
11308
11309

11310
11311
11312
11313
11314

11315
11316
11317

11318
11319
11320

11321
11322
11323

11324
11325
11326

11327
11328
11329

11330
11331

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
10G2,5
12G2,5
16G2,5
18G2,5
20G2,5
25G2,5
30G2,5

2x4
3G4
4G4
5G4
7G4
8G4
10G4
12G4
16G4
18G4

2x6
3G6
4G6
5G6
7G6

2x10
3G10
4G10
5G10
7G10

2x16
3G16
4G16
5G16
7G16

3G25
4G25
5G25

3G35
4G35
5G35

3G50
4G50
5G50

3G70
4G70
5G70

3G95
4G95
5G95

3G120
4G120

Outer
app. mm
7,6
8,3
9,1
10,2
12,1
13,2
14,7
15,2
17,5
18,1
18,7
22,2
23,7

9,2
9,9
11,0
12,1
13,3
15,9
17,3
18,3
20,2
21,8

10,8
11,7
13,0
14,5
16,0

14,0
15,0
16,8
18,7
20,6

16,5
17,6
19,7
21,9
24,4

22,5
25,2
27,9

25,2
28,0
31,0

29,5
33,4
37,2

37,0
41,2
46,0

41,0
46,0
50,5

45,7
50,3

Cop.
weight
kg / km
48,0
72,0
96,0
120,0
168,0
192,0
240,0
288,0
384,0
432,0
480,0
600,0
720,0

77,0
115,0
154,0
192,0
269,0
307,0
384,0
461,0
614,0
691,0

115,0
173,0
230,0
288,0
403,0

192,0
288,0
384,0
480,0
672,0

307,0
461,0
614,0
768,0
1075,0

720,0
960,0
1200,0

1008,0
1344,0
1680,0

1440,0
1920,0
2400,0

2016,0
2688,0
3360,0

2736,0
3648,0
4560,0

3456,0
4608,0

Weight
app.
kg / km
118,0
151,0
181,0
224,0
316,0
370,0
451,0
499,0
720,0
769,0
911,0
1047,0
1280,0

199,0
247,0
299,0
369,0
463,0
601,0
698,0
790,0
1130,0
1280,0

266,0
360,0
429,0
529,0
631,0

440,0
550,0
708,0
862,0
1124,0

642,0
830,0
1060,0
1270,0
1794,0

1190,0
1594,0
2014,0

1590,0
2200,0
2693,0

2571,0
3087,0
3980,0

3207,0
4077,0
5501,0

4708,0
5590,0
6972,0

5515,0
7100,0

AWG-No.
14
14
14
14
14
14
14
14
14
14
14
14
14

12
12
12
12
12
12
12
12
12
12

10
10
10
10
10

8
8
8
8
8

6
6
6
6
6

4
4
4

2
2
2

1
1
1

2/0
2/0
2/0

3/0
3/0
3/0

4/0
4/0

Masters: 13344 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

MEGAFLEX 500

halogen-free, flame retardant, oil-resistant,

UV-resistant, flexible, meter marking

Technical data

Cable structure

Properties

Halogen-free flexible control cable, adapted


to EDINVDE0281 part14
Temperature range
flexing -30C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 4x cable
Flexible
Alternate bending test according to DIN
VDE 0281-2

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free special
polymer
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layer with optimal
lay-length
Outer sheath, halogen-free special polymer
Outer jacket colour grey (RAL7001)
with meter marking, change-over in 2009
The materials used in manufacture are
cadmium-free and contain no silicone and
are free from substances harmful to the
wetting properties of lacquers
LS0H = Low Smoke Zero Halogen-free.

Approved to UL/CSA
see section N, page N 36

Halogen-free
Highly flame-retardant
Resistant to oils and greases
Resistant to UV and weathering
Hydrolysis resistant
Flexible, abrasion- and wear-resistant
Ozone-resistant
Recycleable
Flame test to VDE0482 part266-2-4/
BS4066 part3/ EN50266-2/ IEC60332-3-24
(previously DINVDE0472 part804 test
methodC)
Self-extinguishing and flame retardant
according to DINVDE0482-332-1-2, DIN
EN/IEC60332-1 (previously DINVDE0472
part804 test methodB)
Corrosiveness of combustion gases
according to NFX10-702
Halogen-free according to DINVDE0482
part267/ EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to DINVDE0482
part1034-1+2, DINEN61034-1+2/
IEC61034-1+2, BS7622 part1+2 (previously
DINVDE0472 part816)
Oil-resistant to VDE 0473 part 811-2-1
Hydrolysis-resistant to DINEN61234-1
Ozone-resistant to DIN EN 60811-2-1 / DIN
VDE 0281-2

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
screened analogue type:
MEGAFLEX 500-C, seepagesA73, N73

Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress,
for high mechanical strain.As a measuring and control cable primarily in machinery and plant contruction, in building and air-conditoning
systems, in warehousing and converying systems, in ship-building and for regenerative types of energy such as in the construction of wind
power stations.
Especially well-suited for use in public buildings, such as airports and train stations, where personal injuries and subsequent damage must
be prevented in the event of a fire. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
13344
13345
13346
13347
13348
13349
13350
13351
13352
13353
13354
13355

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5
8G0,5
10G0,5
12G0,5
16G0,5

Outer
app. mm
4,8
5,1
5,1
5,7
5,7
6,2
6,2
7,4
8,0
8,8
9,1
10,0

Cop.
weight
kg / km
9,6
14,4
14,4
19,0
19,0
24,0
24,0
33,6
38,0
48,0
58,0
76,0

Weight
app.
kg / km
43,0
50,0
50,0
60,0
60,0
71,0
71,0
84,0
101,0
121,0
142,0
183,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA03)

20
20
20
20
20
20
20
20
20
20
20
20

Part No.
13356
13357
13359
13360
13361
13362
13363
13364
13365
13366
13367

No.cores x
cross-sec.
mm
18G0,5
20G0,5
25G0,5
30G0,5
34G0,5
37G0,5
41G0,5
42G0,5
50G0,5
61G0,5
65G0,5

Outer
app. mm
10,7
11,2
12,7
13,5
14,5
15,0
15,8
15,8
17,3
19,4
19,4

Cop.
weight
kg / km
86,0
96,0
120,0
144,0
163,0
178,0
197,0
202,0
240,0
293,0
312,0

Weight
app.
kg / km
204,0
227,0
283,0
324,0
367,0
381,0
417,0
454,0
519,0
635,0
694,0

AWG-No.
20
20
20
20
20
20
20
20
20
20
20
Continuation

A 64

Masters: 13344 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

MEGAFLEX 500

halogen-free, flame retardant, oil-resistant,

UV-resistant, flexible, meter marking


Part No.
13368
13369
13370
13371
13372
13373
13374
13375
13376
13377
13378
13379
13380
13381
13382
13383
13384
13385
13386
13387
13388
13389
13390
13392

13393
13394
13395
13396
13397
13398
13399
13400
13401
13402
13403
13404
13405
13406
13407
13408
13409
13410
13411
13412
13413

13414
13415
13416
13417
13418
13419
13420
13421
13422
13423
13425
13426
13427
13428
13429
13430
13431
13432

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
8G0,75
10G0,75
12G0,75
16G0,75
18G0,75
20G0,75
25G0,75
30G0,75
34G0,75
37G0,75
41G0,75
42G0,75
50G0,75
61G0,75
65G0,75

2x1
3G1
3x1
4G1
4x1
5G1
7G1
8G1
10G1
12G1
16G1
18G1
20G1
25G1
34G1
37G1
41G1
42G1
50G1
61G1
65G1

2x1,5
3G1,5
3x1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
16G1,5
18G1,5
20G1,5
25G1,5
34G1,5
37G1,5
50G1,5
61G1,5
65G1,5

Outer
app. mm
5,2
5,5
5,5
6,2
6,2
6,8
6,8
8,1
8,1
8,9
9,6
9,9
11,5
11,9
12,6
14,1
15,4
16,4
17,2
17,6
17,6
19,8
20,9
21,5

5,5
6,0
6,0
6,6
6,6
7,2
8,6
9,4
10,4
10,7
12,0
12,7
13,5
15,2
17,4
18,4
18,9
18,9
21,0
22,2
22,8

6,3
6,7
6,7
7,3
8,2
9,8
10,6
11,7
12,1
13,6
14,5
15,2
17,8
19,8
20,2
23,7
25,3
26,0

Cop.
weight
kg / km
14,4
21,6
21,6
29,0
29,0
36,0
36,0
50,0
50,0
58,0
72,0
86,0
115,0
130,0
144,0
180,0
216,0
245,0
260,0
296,0
302,0
360,0
439,0
468,0

19,2
29,0
29,0
38,4
38,4
48,0
67,0
77,0
96,0
115,0
154,0
173,0
192,0
240,0
326,0
355,0
394,0
403,0
480,0
586,0
628,0

29,0
43,0
43,0
58,0
72,0
101,0
115,0
144,0
173,0
230,0
259,0
288,0
360,0
490,0
533,0
720,0
878,0
936,0

Weight
app.
kg / km
47,0
56,0
56,0
69,0
69,0
83,0
83,0
114,0
114,0
136,0
172,0
183,0
241,0
266,0
291,0
374,0
450,0
517,0
541,0
611,0
621,0
742,0
853,0
909,0

63,0
74,0
74,0
90,0
90,0
109,0
151,0
184,0
224,0
243,0
314,0
361,0
387,0
496,0
670,0
713,0
784,0
824,0
952,0
1140,0
1201,0

70,0
94,0
94,0
112,0
141,0
191,0
224,0
282,0
311,0
392,0
450,0
497,0
630,0
842,0
897,0
1277,0
1460,0
1612,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA03)

A 65

19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19

18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Part No.
13433
13434
13435
13436
13437
13438
13439
13440
13441
13442
13443
13444
13445

13446
13447
13448
13449
13450
13451
13452
13453
13454
13455

13456
13457
13458
13459
13460

13461
13462
13463
13464
13465

13466
13467
13468
13469
13470

13471
13472
13473

13474
13475
13476

13477
13478
13479

13480
13481
13482

13483
13484
13485

13486
13487

13488
13489

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
8G2,5
10G2,5
12G2,5
16G2,5
18G2,5
20G2,5
25G2,5
30G2,5

2x4
3G4
4G4
5G4
7G4
8G4
10G4
12G4
16G4
18G4

2x6
3G6
4G6
5G6
7G6

2x10
3G10
4G10
5G10
7G10

2x16
3G16
4G16
5G16
7G16

3G25
4G25
5G25

3G35
4G35
5G35

3G50
4G50
5G50

3G70
4G70
5G70

3G95
4G95
5G95

3G120
4G120

3G150
4G150

Outer
app. mm
7,6
8,3
9,1
10,2
12,1
13,2
14,7
15,2
17,5
18,1
18,7
22,2
23,7

9,2
9,9
11,0
12,1
13,3
15,9
17,3
18,3
20,2
21,8

10,8
11,7
13,0
14,5
16,0

14,0
15,0
16,8
18,7
20,6

16,5
17,6
19,7
21,9
24,4

22,5
25,2
27,9

25,2
28,0
31,0

29,5
33,4
37,2

37,0
41,2
46,0

41,0
46,0
50,5

45,7
50,3

52,2
57,0

Cop.
weight
kg / km
48,0
72,0
96,0
120,0
168,0
192,0
240,0
288,0
384,0
432,0
480,0
600,0
720,0

77,0
115,0
154,0
192,0
269,0
307,0
384,0
461,0
614,0
691,0

115,0
173,0
230,0
288,0
403,0

192,0
288,0
384,0
480,0
672,0

307,0
461,0
641,0
768,0
1075,0

720,0
960,0
1200,0

1008,0
1344,0
1680,0

1440,0
1920,0
2400,0

2016,0
2688,0
3360,0

2736,0
3648,0
4560,0

3456,0
4608,0

4320,0
5760,0

Weight
app.
kg / km
118,0
151,0
181,0
224,0
316,0
370,0
451,0
499,0
720,0
769,0
911,0
1047,0
1280,0

199,0
247,0
299,0
369,0
463,0
601,0
698,0
790,0
1130,0
1280,0

266,0
360,0
429,0
529,0
631,0

440,0
550,0
708,0
862,0
1124,0

642,0
830,0
1060,0
1270,0
1794,0

1190,0
1594,0
2014,0

1590,0
2200,0
2693,0

2571,0
3087,0
3980,0

3207,0
4077,0
5501,0

4708,0
5590,0
6972,0

5515,0
7100,0

6279,0
7781,0

AWG-No.
14
14
14
14
14
14
14
14
14
14
14
14
14

12
12
12
12
12
12
12
12
12
12

10
10
10
10
10

8
8
8
8
8

6
6
6
6
6

4
4
4

2
2
2

1
1
1

2/0
2/0
2/0

3/0
3/0
3/0

4/0
4/0

300 kcmil
300 kcmil

Masters: 12723 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

JZ-600 HMH

flexible control cable, halogen-free, extremely fire resistant,

oil resistant1), 0,6/1kV, meter marking

Technical data

Cable structure

Properties

Halogen-free, flexible control cable, core


construction adapted to EDINVDE0281
part14 and DINVDE0281 part13
Temperature range
flexing -15C to +70C
fixed -40C to +70C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
for permanent bending
approx. 15x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 and/or
IEC60228 cl.5
Halogen-free polymer core insulation, TI6
acc. to EDINVDE0281 Part14
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Halogen-free polymer sheath, TM7 acc. to
EDINVDE0281 Part14
Sheath colour black (RAL9005)
with meter marking, change-over in 2009
LS0H = Low Smoke Zero Halogen-free.

) For critical applications recommend you


request a consultation
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test acc. to VDE0482 Part266-2,
BS4066 Part3/ DINEN50266-2/
IEC60332-3 (as per DINVDE0472 Part804
Test MethodC)
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Corrosiveness of corrosive gases acc. to
VDE0482, Part267/ DINEN50267-2-2/
IEC607542 (as per DINVDE0472, Part813)
Halogen-free acc. to VDE0482, Part267/
DINEN50267-2-1/ IEC60754-1 (as per
DINVDE0472, Part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
screened analogue type:
JZ-600 HMH-C, seepageA75

Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as
in plant installations, in heating and air-conditioning systems and steel production works. For fixed installation or flexible application, directed
without forcing by casual, constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is
suitable for the application in dry, damp and wet environments and outdoors (fixed installation) and for laying on, in and under plaster as
well as in concrete and masonry excluding in direct laying in vibration, compacted or compressed concrete.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
12723
12724
12725
12726
12727
12728
12729
12730
12731
12732
12733
12734

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
5x0,5
7G0,5
10G0,5
12G0,5
18G0,5
25G0,5

Outer
app. mm
6,4
6,8
6,8
7,6
7,6
8,2
8,2
9,8
11,6
12,2
14,4
17,2

Cop.
weight
kg / km
9,6
14,4
14,4
19,0
19,0
24,0
24,0
33,6
48,0
58,0
86,0
120,0

Weight
app.
kg / km
57,0
69,0
69,0
104,0
104,0
121,0
121,0
145,0
186,0
224,0
292,0
357,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA03)

20
20
20
20
20
20
20
20
20
20
20
20

Part No.
12735
12736
12737
12738
12739
12740
12741
12742
12743
12744
12745
12746

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
10G0,75
12G0,75
18G0,75
25G0,75

Outer
app. mm
6,8
7,2
7,2
8,0
8,0
8,8
8,8
10,7
12,7
13,1
15,6
18,9

Cop.
weight
kg / km
14,4
21,6
21,6
29,0
29,0
36,0
36,0
50,0
72,0
86,0
130,0
180,0

Weight
app.
kg / km
68,0
77,0
77,0
136,0
136,0
152,0
152,0
208,0
250,0
271,0
387,0
498,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
Continuation

A 66

Masters: 12723 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

JZ-600 HMH

flexible control cable, halogen-free, extremely fire resistant,

oil resistant1), 0,6/1kV, meter marking


Part No.
12747
12748
12749
12750
12751
12752
12753
12754
12755
12756
12757
12758

12759
12760
12761
12762
12763
12764
12765
12766
12767
12768
12769
12770

12771
12772
12773
12774
12775
12776
12777
12778
12779
12780
12781
12782

No.cores x
cross-sec.
mm
2x1
3G1
3x1
4G1
4x1
5G1
5x1
7G1
10G1
12G1
18G1
25G1

2x1,5
3G1,5
3x1,5
4G1,5
4x1,5
5G1,5
5x1,5
7G1,5
10G1,5
12G1,5
18G1,5
25G1,5

2x2,5
3G2,5
3x2,5
4G2,5
4x2,5
5G2,5
5x2,5
7G2,5
10G2,5
12G2,5
18G2,5
25G2,5

Outer
app. mm
7,4
8,0
8,0
8,8
8,8
9,8
9,8
11,7
14,1
14,5
17,3
21,1

8,4
9,1
9,1
9,9
9,9
11,0
11,0
13,3
15,9
16,6
19,7
23,9

9,4
9,9
9,9
11,1
11,1
12,4
12,4
15,0
18,4
22,0
24,6
26,9

Cop.
weight
kg / km
19,2
29,0
29,0
38,4
38,4
48,0
48,0
67,0
96,0
115,0
173,0
240,0

29,0
43,0
43,0
58,0
58,0
72,0
72,0
101,0
144,0
173,0
259,0
360,0

48,0
72,0
72,0
96,0
96,0
120,0
120,0
168,0
288,0
432,0
480,0
600,0

Weight
app.
kg / km
82,0
99,0
99,0
140,0
140,0
160,0
160,0
217,0
271,0
301,0
417,0
576,0

97,0
119,0
119,0
148,0
148,0
172,0
172,0
243,0
311,0
392,0
529,0
741,0

160,0
177,0
177,0
209,0
209,0
272,0
272,0
340,0
561,0
799,0
940,0
1121,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA03)

A 67

17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16

14
14
14
14
14
14
14
14
14
14
14
14

Part No.
12783
12784
12785

12786
12787
12788

12789
12790
12791

12792
12793
12794

12795
12796
12797

12798
12799
12800

12801

12802

12803

12804

No.cores x
cross-sec.
mm
3G4
4G4
5G4

3G6
4G6
5G6

3G10
4G10
5G10

3G16
4G16
5G16

3G25
4G25
5G25

3G35
4G35
5G35

4G50

4G70

4G95

4G120

Outer
app. mm
12,3
13,8
15,3

14,1
15,6
17,3

16,5
18,4
20,5

19,1
21,2
23,6

24,0
26,9
29,3

26,2
29,4
32,8

34,2

41,0

46,2

50,3

Cop.
weight
kg / km
115,0
154,0
192,0

173,0
230,0
288,0

288,0
384,0
480,0

461,0
614,0
768,0

720,0
960,0
1200,0

1008,0
1344,0
1680,0

1920,0

2688,0

3648,0

4608,0

Weight
app.
kg / km
255,0
319,0
423,0

380,0
441,0
657,0

668,0
796,0
972,0

832,0
1122,0
1604,0

1457,0
1611,0
2070,0

1914,0
2424,0
2970,0

3467,0

4491,0

6170,0

7618,0

AWG-No.
12
12
12

10
10
10

8
8
8

6
6
6

4
4
4

2
2
2

1

2/0

3/0

4/0

Masters: 11965 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

JB-500 HMH

flexible control cable, coloured core, halogen-free,

extremely fire resistant, oil resistant1), meter marking

Technical data

Cable structure

Properties

Halogen-free flexible control cable, adapted


to EDINVDE0281 part14 and DINVDE0281
part13
Temperature range
flexing -15C to +70C
fixed installation -40C to +70C
Nominal voltage U0/U 450/750 V
Test voltage 3000 V
Minimum bending radius
flexing approx. 12,5x cable
fixed installation approx. 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free compound
TI6, to EDINVDE0281 part14
Colour coded to DIN VDE 0293-308
Green-yellow earth core in the outer layer
Cores stranded in layer with optimal
lay-length
Halogen-free sheath compound TM7, to
EDINVDE0281 part14
Outer jacket colour grey (RAL7001)
with meter marking, change-over in 2009
LS0H = Low Smoke Zero Halogen-free.

) For the critical applications we advise for


consultation
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test to VDE0482 part266-2, BS4066
part3/ DINEN50266-2/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
self-extinguishing and flame retardant
according to VDE0482-332-1-2, DIN
EN60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)

Note
G = with green-yellow earth core.
up to 5 cores with VDE-Reg-No.
screened analogue type:
JB-500 HMH-C, seepageA77

Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as
in plant installations, in air-conditioning and steel production works. For fixed installation or flexible application, directed without forcing by
casual, not constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is suitable for the
application in dry, damp and wet environments and also for laying on, in and under plaster as well as in concrete and masonry excluding in
direct laying in shaked or stamped concrete, not suitable for imbedding in solidified or compressed concrete.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
11965
11966
11967
11968
11969
11970
11971
11972
11973
11974
11975

No.cores x
cross-sec.
mm
3G1,5
4G1,5
5G1,5
3G2,5
4G2,5
5G2,5
3G4
4G4
5G4
4G6
5G6

Outer
app. mm
8,1
8,9
10,0
10,0
10,9
12,0
11,5
12,5
14,0
13,6
15,3

Cop.
weight
kg / km
43,0
58,0
72,0
72,0
96,0
120,0
115,0
154,0
192,0
230,0
288,0

Weight
app.
kg / km
110,0
140,0
181,0
181,0
223,0
269,0
238,0
292,0
357,0
392,0
501,0

AWG-No.
16
16
16
14
14
14
12
12
12
10
10

Part No.
11976
11977
11978
11979
11980
11981
11982
11983
11984
11985
11986
11987

No.cores x
cross-sec.
mm
4G10
5G10
4G16
5G16
4G25
5G25
4G35
5G35
4G50
4G70
4G95
4G120

Outer
app. mm
17,4
19,4
20,2
22,5
25,1
28,1
28,6
32,1
34,1
39,2
44,7
50,3

Cop.
weight
kg / km
384,0
480,0
614,0
768,0
960,0
1200,0
1344,0
1680,0
1920,0
2688,0
3648,0
4608,0

Weight
app.
kg / km
750,0
916,0
1037,0
1280,0
1504,0
1883,0
2057,0
2575,0
2808,0
3964,0
4951,0
6387,0

AWG-No.
8
8
6
6
4
4
2
2
1
2/0
3/0
4/0

Dimensions and specifications may be changed without prior notice. (RA03)

A 68

Masters: 3233_ - ProductGroupID: PG2606 - Layout: L100_1 - Umbruch:

(H)03 Z1Z1-F

halogen-free, meter marking

Technical data

Cable structure

flexible halogen-free control cable


according E DINVDE0281 part14 pr HD
21.14 S1
Temperature range
flexing -5C to +70C
fixed installation -40C to +70C
Nominal voltage
U0/U 300/300 V
Test voltage 2000 V
Breakdown voltage min. 4000 V
Minimum bending radius
approx. 7,5x cable
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Bare copper, fine wire conductor, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5, IEC60228 cl.5, HD383
Insulating jacket thermoplastic compound,
TI6 according to DINVDE0281 part14,
appendixA
Core identification according to
DINVDE0293-308
Green-yellow earth core, 3 cores and above
Core stranded with optimal lay-length
Outer sheath, thermoplastic compound,
TM7 according DINVDE0281 part14,
appendixB
Jacket colour by request
with meter marking, change-over in 2009

Properties

Tests
Tested for flame retardation to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Smoke density to VDE0482 part268-2
Halogen-free to HD21.14 appendixC
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Colour code:
0 = RAL 9005, black
1 = RAL 9003, white
2 = RAL 5015, blue
3 = RAL 6018, green
4 = RAL 8003, brown
5 = RAL 1021, yellow
6 = RAL 3000, red
7 = RAL 2003, orange
8 = RAL 4005, violet
9 = RAL 7001/7032, grey
Please add the individual part no. for order
with the identification colour code.
Further colours on request.

Application
These cables may be used when halogen-free, low smoke and corrosive gas properties are required in case of fire. For low mechanical
demands in the house, kitchen and office, for small equipment such as, for example, office machines, radios, table and stranded lamps.
Not suitable for:
Cooking and heating equipment, use in high temperature areas (for example, in lighting equipment), outside use, industrial use or idustrial
electrical tools, cables with a nominal cross-section of 0,75 mm comply with the same recommendations as for cable (H)05Z1Z1-F.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
3233_
3234_
3235_

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5

Outer
app. mm
5,0
5,3
5,8

Cop.
weight
kg / km
9,6
14,4
19,2

Weight
app.
kg / km
39,0
46,0
56,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA03)

A 69

20
20
20

Part No.
3236_
3237_
3238_

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75

Outer
app. mm
5,4
5,7
6,3

Cop.
weight
kg / km
14,4
21,6
29,0

Weight
app.
kg / km
47,0
55,0
69,0

AWG-No.
18
18
18

Masters: 3027_ - ProductGroupID: PG2606 - Layout: L100_1 - Umbruch:

(H)05 Z1Z1-F

halogen-free, meter marking

Technical data

Cable structure

flexible halogen-free control cable


according EDINVDE0281 part14
prHD21.14S1
Temperature range
flexing -5C to +70C
fixed installation -40C to +70C
Nominal voltage
U0/U 300/500 V
Test voltage 2500 V
Breakdown voltage min. 5000 V
Minimum bending radius
approx. 7,5x cable
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad)

Bare copper, fine wire conductor, bunch


stranded to DINVDE0295 cl.5, BS6360
cl.5, IEC60228 cl.5, HD383
Insulating jacket thermoplastic compound,
TI6 according to DINVDE0281 part14,
appendixA
Core identification according to
DINVDE0293-308
Green-yellow earth core, 3 cores and above
Core stranded with optimal lay-length
Outer sheath, thermoplastic compound,
TM7 according DINVDE0281 part14,
appendixB
Jacket colour by request
with meter marking, change-over in 2009

Properties

Tests
Tested for flame retardation to VDE
0482-332-1-2, DIN EN 60332-1-2/
IEC60332-1 (equivalent DINVDE0472
part804 test methodB)
Smoke density to VDE0482 part268-2
Halogen-free to HD21.14 appendixC
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Colour code:
0 = RAL 9005, black
1 = RAL 9003, white
2 = RAL 5015, blue
3 = RAL 6018, green
4 = RAL 8003, brown
5 = RAL 1021, yellow
6 = RAL 3000, red
7 = RAL 2003, orange
8 = RAL 4005, violet
9 = RAL 7001/7032, grey
Please add the individual part no. for order
with the identification colour code.
Further colours on request.

Application
These cables may be used when halogen-free, low smoke and corrosive gas properties are required in case of fire. For moderate mechanical
demands in the house, kitchen and office, for house equipment in damp rooms (for example: washing machines, spin-dryers and refrigerators).
Suitable for cooking and heating equipment, providing the cable is not in contact with hot components or heat radiation.
Not suitable for:
in high temperature areas (for example, in lighting equipment), outside buildings, in industrial or agricultural buildings, connection of
electrical power tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
3027_
3028_
3029_
3030_

3031_
3032_
3034_
3035_

3036_
3037_
3038_
3039_

No.cores x
cross-sec.
mm
2x0,75
3G0,75
4G0,75
5G0,75

2x1
3G1
4G1
5G1

2x1,5
3G1,5
4G1,5
5G1,5

Outer
app. mm
6,2
6,6
7,1
8,0

6,6
6,9
7,7
8,4

7,4
8,1
9,0
10,0

Cop.
weight
kg / km
14,4
21,6
29,0
36,0

19,0
29,0
38,0
48,0

29,0
43,0
58,0
72,0

Weight
app.
kg / km
58,0
68,0
81,0
102,0

67,0
81,0
101,0
107,0

87,0
109,0
117,0
169,0

AWG-No.
18
18
18
18

17
17
17
17

16
16
16
16

Part No.
3040_
3041_
3042_
3043_

3044_
3045_
3046_
3047_

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5

2x4
3G4
4G4
5G4

Outer
app. mm
9,3
10,1
11,0
12,3

10,6
11,5
12,5
14,1

Cop.
weight
kg / km
48,0
72,0
96,0
120,0

76,8
115,2
153,6
192,0

Weight
app.
kg / km
138,0
172,0
210,0
260,0

190,0
242,0
298,0
371,0

AWG-No.
14
14
14
14

12
12
12
12

Dimensions and specifications may be changed without prior notice. (RA03)

A 70

Masters: 11656 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

JZ-500 HMH-C

flexible control cable, halogen-free, extremely fire

resistant, oil resistant1), Cu-screened, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Halogen-free core flexible control cable


adapted to EDINVDE0281 part14 and
DINVDE0281 part13
Temperature range
flexing -15C to +70C
fixed installation -40C to +70C
Nominal voltage U0/U 300/500 V
Test voltage 2000 V
Minimum bending radius
flexing approx. 12,5x cable
fixed installation approx. 4x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free compound
TI6, to EDINVDE0281 part14
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores laid up in layers with optimal
lay-length
Separating layer
Screen braid of tinned copper wires,
coverage approx. 85%
Halogen-free sheath compound TM7, to
EDINVDE0281 part14
Jacket colour grey (RAL7001)
with meter marking, change-over in 2009
LS0H = Low Smoke Zero Halogen-free.

) For the critical applications we advise for


consultation
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test to VDE0482 part266-2, BS4066
part3/ DINEN50266-2/ IEC60332-3
(equivalent DINVDE0472 part804 test
methodC)
self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Corrosiveness of combustion gases
according to VDE0482 part267/
DINEN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to VDE0482
part267/ DINEN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
unscreened analogue type:
JZ-500 HMH, seepageA62

Application
Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation
belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing
applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical
loads. The cable is suitable for use in dry, damp and wet environments for installation above, on, in and beneath plaster as well as in masonry
and concrete walls except for direct embedding in vibrated, compacted or tamped concrete, not suitable for imbedding in solidified or
compressed concrete.
An interference-free transmission of signals and pulse in assured by the high degree of screening.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
11656
11657
11342
11658
11343
11659
11660
11663
11665
11667

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3x0,5
4G0,5
4x0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5

Outer
app. mm
5,7
6,0
6,0
6,5
6,5
7,0
7,9
9,6
11,2
13,4

Cop.
weight
kg / km
35,0
42,0
42,0
47,0
47,0
56,0
69,0
108,0
145,0
240,0

Weight
app.
kg / km
46,0
56,0
56,0
62,0
62,0
75,0
98,0
158,0
216,0
315,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA03)

A 71

20
20
20
20
20
20
20
20
20
20

Part No.
11678
11679
11344
11680
11345
11681

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75

Outer
app. mm
6,1
6,4
6,4
6,9
6,9
7,4

Cop.
weight
kg / km
40,0
52,0
52,0
60,0
60,0
71,0

Weight
app.
kg / km
60,0
68,0
68,0
78,0
78,0
95,0

AWG-No.
18
18
18
18
18
18

Continuation

Masters: 11656 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

JZ-500 HMH-C

flexible control cable, halogen-free, extremely fire

resistant, oil resistant1), Cu-screened, EMC-preferred type, meter marking


Part No.
11346
11682
11347
11685
11687
11689

11700
11701
11348
11702
11349
11703
11704
11707
11709
11711

11722
11723
11350
11724
11725
11726
11729
11731
11733

11744
11745
11746
11747
11748
11751

11766
11768
11769
11770
11771

No.cores x
cross-sec.
mm
5x0,75
7G0,75
7x0,75
12G0,75
18G0,75
25G0,75

2x1
3G1
3x1
4G1
4x1
5G1
7G1
12G1
18G1
25G1

2x1,5
3G1,5
3x1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5

2x4
3G4
4G4
5G4
7G4

Outer
app. mm
7,4
8,6
8,6
10,4
12,4
14,8

6,4
6,7
6,7
7,3
7,3
7,8
9,1
11,2
13,2
15,8

6,6
6,9
6,9
7,5
8,4
10,0
12,1
14,6
17,6

8,3
9,0
9,8
10,9
12,9
15,9

9,8
10,6
11,5
12,7
14,0

Cop.
weight
kg / km
71,0
91,0
91,0
142,0
212,0
281,0

50,0
60,0
60,0
71,0
71,0
88,0
111,0
184,0
260,0
349,0

63,0
80,0
80,0
97,0
119,0
147,0
267,0
374,0
526,0

96,0
144,0
148,0
181,0
255,0
441,0

120,0
174,0
230,0
273,0
316,0

Weight
app.
kg / km
95,0
130,0
130,0
203,0
290,0
413,0

66,0
80,0
80,0
100,0
100,0
130,0
160,0
260,0
382,0
540,0

88,0
100,0
100,0
125,0
158,0
210,0
340,0
480,0
702,0

132,0
168,0
195,0
222,0
345,0
572,0

184,0
238,0
305,0
388,0
504,0

AWG-No.
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16

14
14
14
14
14
14

12
12
12
12
12

Part No.
11781
11782
11783
11784
11785

11786
11787
11788
11789
11790

11793
11794
11812

11795
11796
11797

11798
11799
11800

11801
11802
11803

11804
11805
11806

11807
11808
11809

11810
11811

No.cores x
cross-sec.
mm
2G6
3G6
4G6
5G6
7G6

2x10
3G10
4G10
5G10
7G10

4G16
5G16
7G16

3G25
4G25
5G25

3G35
4G35
5G35

3G50
4G50
5G50

3G70
4G70
5G70

3G95
4G95
5G95

3G120
4G120

Outer
app. mm
11,5
12,4
13,8
15,7
16,6

14,9
15,9
17,8
19,6
21,6

20,8
22,9
25,0

23,2
26,2
29,4

25,7
30,4
33,8

30,0
34,6
38,8

37,6
41,3
46,1

41,2
46,2
51,2

46,5
51,0

Cop.
weight
kg / km
173,0
240,0
305,0
439,0
505,0

255,0
350,0
535,0
592,0
810,0

740,0
895,0
1282,0

1070,0
1140,0
1380,0

1240,0
1576,0
1930,0

1675,0
2155,0
2794,0

2288,0
3120,0
3705,0

3010,0
4043,0
5026,0

3812,0
5069,0

Weight
app.
kg / km
270,0
328,0
416,0
510,0
670,0

420,0
495,0
785,0
855,0
1308,0

882,0
1293,0
2149,0

1432,0
1911,0
2414,0

1914,0
2542,0
3180,0

3080,0
3550,0
4753,0

3840,0
4939,0
6572,0

5651,0
6690,0
8370,0

6342,0
8453,0

AWG-No.
10
10
10
10
10

8
8
8
8
8

6
6
6

4
4
4

2
2
2

1
1
1

2/0
2/0
2/0

3/0
3/0
3/0

4/0
4/0

Dimensions and specifications may be changed without prior notice. (RA03)

A 72

Masters: 13500 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

MEGAFLEX 500-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, screened, EMC-preferred types, meter marking

Technical data

Cable structure

Properties

Halogen-free flexible control cable, adapted


to EDINVDE0281 part14
Temperature range
flexing -30C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Minimum bending radius
flexing approx. 10x cable
fixed installation approx. 4x cable
Flexible
Alternate bending test according to DIN
VDE 0281-2
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free special
polymer
Black cores with white continuous
numbering to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layer with optimal
lay-length
Separating foil
Tinned copper braided screening, coverage
approx. 85%
Outer sheath, halogen-free special polymer
Outer jacket colour grey (RAL7001)
with meter marking, change-over in 2009
The materials used in manufacture are
cadmium-free and contain no silicone and
are free from substances harmful to the
wetting properties of lacquers
LS0H = Low Smoke Zero Halogen-free.

Approved to UL/CSA
see section N, page N 38

Halogen-free
Highly flame-retardant
Resistant to oils and greases
Resistant to UV and weathering
Flexible, abrasion- and wear-resistant
Ozone-resistant
Recycleable
Flame test to VDE0482 part266-2-4/
BS4066 part3/ EN50266-2/ IEC60332-3-24
(previously DINVDE0472 part804 test
methodC)
Self-extinguishing and flame retardant
according to DINVDE0482-332-1-2, DIN
EN/IEC60332-1 (previously DINVDE0472
part804 test methodB)
Corrosiveness of combustion gases
according to NFX10-702
Halogen-free according to DINVDE0482
part267/ EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to DINVDE0482
part1034-1+2, DINEN61034-1+2/
IEC61034-1+2, BS7622 part1+2 (previously
DINVDE0472 part816)
Oil-resistant to VDE0473 part811-2-1
hydrolysebestndig nach DINEN61234-1
Ozone-resistant to DIN EN 60811-2-1 / DIN
VDE 0281-2

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
unscreened analogue type:
MEGAFLEX 500, seepagesA64, N36

Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress,
for high mechanical strain.An interference-free transmission of signals and pulse in assured by the high degree of screening.
As a measuring and control cable primarily in machinery and plant contruction, in building and air-conditoning systems, in warehousing and
converying systems, in ship-building and for regenerative types of energy such as in the construction of wind power stations.
Especially well-suited for use in public buildings, such as airports and train stations, where personal injuries and subsequent damage must
be prevented in the event of a fire.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
13500
13501
13502
13503
13504
13505
13506
13507

No.cores x
cross-sec.
mm
2x0,5
3G0,5
3G0,5
4G0,5
4G0,5
5G0,5
5x0,5
7G0,5

Outer
app. mm
5,7
6,0
6,0
6,5
6,5
7,0
7,0
7,9

Cop.
weight
kg / km
35,0
42,0
42,0
47,0
47,0
56,0
56,0
69,0

Weight
app.
kg / km
46,0
56,0
56,0
62,0
62,0
75,0
75,0
98,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA03)

A 73

20
20
20
20
20
20
20
20

Part No.
13508
13509
13510
13511
13512
13514
13515

No.cores x
cross-sec.
mm
8G0,5
10G0,5
12G0,5
16G0,5
18G0,5
20G0,5
25G0,5

Outer
app. mm
8,5
9,3
9,6
10,7
11,2
11,9
13,4

Cop.
weight
kg / km
80,0
94,0
108,0
129,0
145,0
172,0
240,0

Weight
app.
kg / km
116,0
135,0
158,0
210,0
216,0
240,0
315,0

AWG-No.
20
20
20
20
20
20
20
Continuation

Masters: 13500 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

MEGAFLEX 500-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, screened, EMC-preferred types, meter marking
Part No.
13516
13517
13518
13519
13520
13521
13522
13523
13524
13525
13526
13527
13528
13529
13530
13531

13532
13533
13534
13535
13536
13537
13538
13539
13540
13541
13542
13543
13544
13545

13546
13547
13548
13549
13550
13552
13554
13556
13557
13558
13559
13560
13561

No.cores x
cross-sec.
mm
2x0,75
3G0,75
3x0,75
4G0,75
4x0,75
5G0,75
5x0,75
7G0,75
7x0,75
8G0,75
10G0,75
12G0,75
16G0,75
18G0,75
20G0,75
25G0,75

2x1
3G1
3x1
4G1
4x1
5G1
7G1
8G1
10G1
12G1
16G1
18G1
20G1
25G1

2x1,5
3G1,5
3x1,5
4G1,5
5G1,5
7G1,5
8G1,5
10G1,5
12G1,5
16G1,5
18G1,5
20G1,5
25G1,5

Outer
app. mm
6,1
6,4
6,4
6,9
6,9
7,4
7,4
8,6
8,6
9,4
10,0
10,4
11,6
12,4
12,9
14,8

6,4
6,7
6,7
7,3
7,3
7,8
9,1
9,9
10,8
11,2
12,3
13,2
13,8
15,8

6,6
6,9
6,9
7,5
8,4
10,0
11,1
12,0
12,1
14,3
14,6
15,9
17,6

Cop.
weight
kg / km
40,0
52,0
52,0
60,0
60,0
71,0
71,0
91,0
91,0
110,0
137,0
142,0
200,0
212,0
238,0
281,0

50,0
60,0
60,0
71,0
71,0
88,0
111,0
127,0
150,0
184,0
209,0
260,0
317,0
349,0

63,0
80,0
80,0
97,0
119,0
147,0
170,0
193,0
267,0
315,0
374,0
396,0
526,0

Weight
app.
kg / km
60,0
68,0
68,0
78,0
78,0
95,0
95,0
130,0
130,0
145,0
180,0
203,0
275,0
290,0
320,0
413,0

66,0
80,0
80,0
100,0
100,0
130,0
160,0
197,0
232,0
260,0
346,0
382,0
440,0
540,0

88,0
100,0
100,0
125,0
158,0
210,0
244,0
315,0
340,0
424,0
480,0
545,0
702,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16

Part No.
13562
13563
13565
13566
13567
13568
13569
13570

13571
13572
13573
13574
13575

13576
13577
13578
13579
13580

13581
13582
13583
13584
13585

13586
13587
13588
13589
13590

13591

13592

13593

13594

13595

13596

13597

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5x2,5
7G2,5
8G2,5
10G2,5
12G2,5

2x4
3G4
4G4
5G4
7G4

2x6
3G6
4G6
5G6
7G6

2x10
3G10
4G10
5G10
7G10

2x16
3G16
4G16
5G16
7G16

4G25

4x35

4G50

4G70

4G95

4G120

4G150

Outer
app. mm
8,3
9,0
9,8
10,9
12,9
13,1
15,2
15,9

9,8
10,6
11,5
12,7
14,0

11,5
12,4
13,8
15,7
16,6

14,9
15,9
17,8
19,6
21,6

17,2
19,0
20,8
22,9
25,0

26,2

30,4

34,6

41,3

46,2

51,0

59,2

Cop.
weight
kg / km
96,0
144,0
148,0
181,0
255,0
285,0
340,0
441,0

120,0
174,0
230,0
273,0
316,0

173,0
240,0
305,0
439,0
505,0

255,0
350,0
535,0
592,0
810,0

422,0
585,0
740,0
895,0
1282,0

1140,0

1576,0

2155,0

3120,0

4043,0

5069,0

5792,0

Weight
app.
kg / km
132,0
168,0
195,0
256,0
345,0
390,0
482,0
572,0

220,0
251,0
305,0
388,0
504,0

270,0
351,0
464,0
546,0
670,0

461,0
574,0
785,0
914,0
1308,0

670,0
911,0
1105,0
1293,0
2149,0

1911,0

2542,0

3550,0

4939,0

6690,0

8453,0

9104,0

AWG-No.
14
14
14
14
14
17
14
14

12
12
12
12
12

10
10
10
10
10

8
8
8
8
8

6
6
6
6
6

4

2

1

2/0

3/0

4/0

300 kcmil

Dimensions and specifications may be changed without prior notice. (RA03)

A 74

Masters: 12850 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

JZ-600 HMH-C

flexible control cable, halogen-free, extremely fire resistant,

oil resistant 1), 0,6/1kV, screened, EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Halogen-free, flexible control cable, core


construction adapted to EDINVDE0281
Part14 and DINVDE0281 Part13
Temperature range
flexing -5C to +70C
fixed -40C to +70C
Nominal voltage U0/U 0,6/1 kV
Test voltage 4000 V
Minimum bending radius
for permanent bending
approx. 15x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductor to


DINVDE0295 cl.5, BS6360 cl.5 and/or
IEC60228 cl.5
Halogen-free polymer core insulation, TI6
acc. to EDINVDE0281 Part14
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Inner sheath
Tinned copper braided screening, coverage
approx. 85%
Free-free polymer sheath, TM7 acc. to
EDINVDE0281 Part14
Sheath colour black (RAL 9005)
with meter marking, change-over in 2009
LS0H = Low Smoke Zero Halogen-free.
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

) For critical applications recommend you


request a consultation
Tests
Flame test acc. to VDE0482 Part266-2,
BS4066 Part3/ DINEN50266-2/
IEC60332-3 (as per DINVDE0472 Part804
Test MethodC)
Self-extinguishing and flame-resistant acc.
to DINVDE0482 Part265-2-1/
EN50265-2-1/ IEC60332-1 (as per
DINVDE0472 Part804 Test MethodB)
Corrosiveness of corrosive gases acc. to
VDE0482, Part267/ DINEN50267-2-2/
IEC607542 (as per DINVDE0472, Part813)
Halogen-free acc. to VDE0482, Part267/
DINEN50267-2-1/ IEC60754-1 (as per
DINVDE0472, Part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)

Note
unscreened analogue type:
JZ-600 HMH, seepageA66

Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as
in plant installations, in heating and air-conditioning systems and steel production works. For fixed installation or flexible application, directed
without forcing by casual, constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is
suitable for the application in dry, damp and wet environments and outdoors (fixed installation) and for laying on, in and under plaster as
well as in concrete and masonry excluding in direct laying in vibration, compacted or compressed concrete. The dense screening assures
interference-free transmission of all signals and impulses.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
12850
12851
12852
12853
12854
12855
12856

12857
12858
12859
12860
12861
12862
12863

12864
12865
12866
12867
12868
12869
12870

No.cores x
cross-sec.
mm
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
25G0,5

3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
25G0,75

3G1
4G1
5G1
7G1
12G1
18G1
25G1

Outer
app. mm
8,6
9,4
10,1
12,1
14,7
17,3
20,6

9,0
9,9
10,8
13,0
15,8
17,9
22,8

9,8
10,8
12,1
14,5
17,4
20,7
24,8

Cop.
weight
kg / km
45,0
54,0
66,0
79,0
137,0
156,0
250,0

57,0
63,0
76,0
100,0
175,0
240,0
306,0

64,0
76,0
89,0
114,0
186,0
284,0
387,0

Weight
app.
kg / km
150,0
170,0
199,0
235,0
320,0
428,0
503,0

155,0
190,0
228,0
323,0
410,0
560,0
730,0

163,0
200,0
239,0
289,0
464,0
628,0
855,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA03)

A 75

20
20
20
20
20
20
20

18
18
18
18
18
18
18

17
17
17
17
17
17
17

Part No.
12871
12872
12873
12874
12875
12876
12877

12878
12879
12880
12881
12882
12883
12884

12885
12886
12887

12888
12889
12890

No.cores x
cross-sec.
mm
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
25G1,5

3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

3G4
4G4
5G4

3G6
4G6
5G6

Outer
app. mm
10,9
12,2
13,3
16,0
19,6
23,4
28,2

12,2
13,4
14,9
17,9
21,9
26,1
31,9

15,1
16,7
18,6

17,0
18,7
20,7

Cop.
weight
kg / km
82,0
99,0
123,0
148,0
274,0
386,0
531,0

148,0
169,0
220,0
284,0
470,0
572,0
740,0

178,0
234,0
284,0

245,0
316,0
442,0

Weight
app.
kg / km
187,0
240,0
289,0
383,0
592,0
806,0
1241,0

298,0
345,0
427,0
561,0
857,0
1355,0
1995,0

391,0
527,0
700,0

629,0
731,0
1105,0

AWG-No.
16
16
16
16
16
16
16

14
14
14
14
14
14
14

12
12
12

10
10
10
Continuation

Masters: 12850 - ProductGroupID: PG2607 - Layout: L100_1 - Umbruch:

JZ-600 HMH-C

flexible control cable, halogen-free, extremely fire resistant,

oil resistant 1), 0,6/1kV, screened, EMC-preferred type, meter marking


Part No.
12891
12892
12893

12894
12895
12896

12897
12898
12899

No.cores x
cross-sec.
mm
3G10
4G10
5G10

4G16
5G16
7G16

3G25
4G25
5G25

Outer
app. mm
19,6
21,9
24,1

23,5
26,4
28,8

28,0
32,5
35,7

Cop.
weight
kg / km
367,0
549,0
604,0

807,0
940,0
1345,0

920,0
1169,0
1420,0

Weight
app.
kg / km
1125,0
1345,0
1635,0

1395,0
1870,0
2720,0

2465,0
2750,0
3490,0

AWG-No.

Part No.
8
8
8

6
6
6

4
4
4

12900
12901
12902

12903

12904

12905

12906

12907

No.cores x
cross-sec.
mm
3G35
4G35
5G35

4G50

4G70

4G95

4G120

4G150

Outer
app. mm
32,7
35,7
40,0

41,1

48,0

51,2

56,0

64,5

Cop.
weight
kg / km
1250,0
1680,0
2020,0

2370,0

3257,0

4060,0

5231,0

6794,0

Weight
app.
kg / km
3230,0
4100,0
4950,0

5780,0

7480,0

10220,0

13750,0

15900,0

AWG-No.
2
2
2

1

2/0

3/0

4/0

4/0

Dimensions and specifications may be changed without prior notice. (RA03)

A 76

Masters: 11942 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

JB-500 HMH-C

flexible control cable, coloured core, halogen-free,

screened, extremely fire resistant, oil resistant1), EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Halogen-free core flexible control cable


adapted to EDINVDE0281 part14 and
DINVDE0281 part13
Temperature range
flexing -15C to +70C
fixed installation -40C to +70C
Nominal voltage U0/U 450/750 V
Test voltage 3000 V
Minimum bending radius
flexing approx. 12,5x cable
fixed installation approx. 4x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, to


DINVDE0295 cl.5, BS6360 cl.5 and
IEC60228 cl.5
Core insulation of halogen-free compound
TI6, to EDINVDE0281 part14
Colour coded to DINVDE0293-308
Green-yellow earth core in the outer layer
Cores laid up in layers with optimal
lay-length
Separating layer
Screen braid of tinned copper wires,
coverage approx. 85%
Halogen-free sheath compound TM7, to
EDINVDE0281 part14
Jacket colour grey (RAL7001)
with meter marking, change-over in 2009
LS0H = Low Smoke Zero Halogen-free.

) For the critical applications we advise for


consultation
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Tests
Flame test to DINVDE0482 part266-2/
HD405.3, BS4066 part3/ EN50266-2/
IEC60332-3 (equivalent DINVDE0472
part804 test methodC)
Self-extinguishing and flame retardant
according to DINVDE0482 part265-2-1/
EN50265-2-1/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
Corrosiveness of combustion gases
according to DINVDE0482 part267/
EN50267-2-2/ IEC60754-2 (equivalent
DINVDE0472 part813)
Halogen-free according to DINVDE0482
part267/ EN50267-2-1/ IEC60754-1
(equivalent DINVDE0472 part815)
Smoke density according to VDE0482
part1034-1+2 / IEC61034-1+2 /
DINEN61034-1+2 / BS7622 part1+2
(equivalent DINVDE0472 part816)

Note
G = with green-yellow earth core
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
unscreened analogue type:
JB-500 HMH, seepageA68

Application
Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation
belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing
applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical
loads. The cable is suitable for use in dry, damp and wet environments for installation above, on, in and beneath plaster as well as in masonry
and concrete walls except for direct embedding in vibrated, compacted or tamped concrete, not suitable for imbedding in solidified or
compressed concrete.
An interference-free transmission of signals and pulse in assured by the high degree of screening.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
11942
11943
11944

11945
11946
11947

No.cores x
cross-sec.
mm
3G1,5
4G1,5
5G1,5

3G2,5
4G2,5
5G2,5

Outer
app. mm
8,4
9,3
10,7

10,8
11,4
12,5

Cop.
weight
kg / km
80,0
97,0
119,0

144,0
148,0
181,0

Weight
app.
kg / km
125,0
160,0
193,0

198,0
240,0
280,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA03)

A 77

16
16
16

14
14
14

Part No.
11948
11949
11950

11951
11952

No.cores x
cross-sec.
mm
3G4
4G4
5G4

4G6
5G6

Outer
app. mm
11,9
13,0
14,6

14,1
15,8

Cop.
weight
kg / km
174,0
230,0
273,0

305,0
439,0

Weight
app.
kg / km
251,0
315,0
396,0

430,0
524,0

AWG-No.
12
12
12

10
10
Continuation

Masters: 11942 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

JB-500 HMH-C

flexible control cable, coloured core, halogen-free,

screened, extremely fire resistant, oil resistant1), EMC-preferred type, meter marking
Part No.
11953
11954

11955
11956

11957
11958

No.cores x
cross-sec.
mm
4G10
5G10

4G16
5G16

4G25
5G25

Outer
app. mm
17,9
19,9

21,0
23,1

26,7
29,7

Cop.
weight
kg / km
535,0
592,0

740,0
895,0

1140,0
1380,0

Weight
app.
kg / km
804,0
942,0

1190,0
1370,0

1968,0
2514,0

AWG-No.

Part No.
8
8

6
6

4
4

11959
11960

11961

11962

11963

11964

No.cores x
cross-sec.
mm
4G35
5G35

4G50

4G70

4G95

4G120

Outer
app. mm
30,6
34,0

35,0

41,5

46,8

51,9

Cop.
weight
kg / km
1576,0
1930,0

2155,0

3120,0

4043,0

5069,0

Weight
app.
kg / km
2540,0
3260,0

3668,0

5076,0

6807,0

8612,0

AWG-No.
2
2

1

2/0

3/0

4/0

Dimensions and specifications may be changed without prior notice. (RA03)

A 78

OZ-BL
OZ-BL-CY
OB-BL-PAAR-CY
Photo: INDUSTRONIC*

PVC Control Cables for Intrinsically Safe Circuits


Electrical cables for intrinsically safe circuits
(separate power circuit of hazard type-i-) have
to be specially marked with a blue outer sheath
(RAL 5015) according to DIN VDE. HELUKABEL
manufactures these cables according to DIN VDE
0165 and in addition, screened types according
to DIN VDE 0165, part 1, EN 60079-14 and IEC
60079-14 section 12.2.2.6.
As these cables are installed with separate power
circuit, the application of green-yellow protective
conductor is not allowed.

The installation of these cables outside of intrinsically safe circuits is not permitted. The installation
can be done in dry and damp environments, but
not in underground and in open air.
The special PVC outer sheath material is resistant
to oil and petrol as well as being ame resistant.
HELUKABEL can deliver almost all the cables as
per typelists on the following pages, predominantly available in stock.
Special cables can be manufactured in a short time.
* INDUSTRONIC installation of intercom telephone equipment in hazardous area in
DMT-plant of Dynamit-Nobel AG, workshop in Witten.

A 79

31472-00e-A079.indd 110

03.04.2009 7:38:55 Uhr

Masters: 14001 - ProductGroupID: PG1501 - Layout: L104_1 - Umbruch:

OZ-BL

outer jacket blue, intrinsic safety, flexible, meter marking

Technical data

Cable structure

Properties

Control cable, special PVC with blue outer


jacket for hazardous areas to hazard type
-i- (=intrinsically safe)
For intrinsically safe installation according
to DINEN60079-14 and IEC60079-14
section12.2.2 (VDE0165 part1)
Temperature range
flexing -15C1) to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance
core/core approx. 120 nF/km
Inductance approx. 0,68 mH/km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
1) cold bending test, impact resistance test
at low temperatures, elongation test at low
temperatures. Tested according VDE0473
Teil811-1-4, EN60811-1-4

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Core insulation of special PVC Z7225
Black cores with white continuous figure
imprint to DINVDE0293 without earth core
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath TM2, to
DINVDE0281 part1 and HD21.1
Colour blue (RAL5015)
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations.
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
For underground laying use NYY with blue
outer sheath.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Instrumentation cable RE-2Y(St)Yv with blue
outer jacket see catalog part B.

Application
For hazardous areas the cables with special marking (blue) (hazard type-i-) used as flexible control and measuring cables to meet the
requirements for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Those cables
are not suitable for underground laying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
14001
14002
14003
14004
14075
14005
14076
14006
14007
14008
14009
14010

14011
14012
14013
14014
14015
14016
14017
14018

No.cores x
cross-sec.
mm
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
8x0,75
12x0,75
18x0,75
25x0,75
30x0,75
34x0,75
41x0,75

2x1
3x1
4x1
5x1
7x1
12x1
18x1
25x1

Outer
app. mm
5,2
5,5
6,2
6,8
8,1
8,9
9,9
11,9
14,5
15,8
16,4
17,6

5,5
6,0
6,6
7,2
8,6
10,7
12,7
15,6

Cop.
weight
kg / km
14,4
21,6
29,0
36,0
52,0
58,0
88,0
130,0
180,0
215,0
245,0
298,0

19,0
29,0
38,0
48,0
67,0
115,0
173,0
240,0

Weight
app.
kg / km
46,0
54,0
66,0
80,0
110,0
130,0
179,0
257,0
365,0
448,0
510,0
607,0

60,0
72,0
86,0
104,0
141,0
230,0
343,0
485,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17

Part No.
14019
14020
14021
14022
14023
14024
14025
14026
14027

14100
14101
14102

No.cores x
cross-sec.
mm
2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
12x1,5
18x1,5
25x1,5
30x1,5

3x2,5
4x2,5
5x2,5

Outer
app. mm
6,3
6,7
7,3
8,2
9,8
12,1
14,5
17,8
20,0

8,3
9,1
10,2

Cop.
weight
kg / km
29,0
43,0
58,0
72,0
101,0
173,0
259,0
360,0
440,0

72,0
96,0
120,0

Weight
app.
kg / km
70,0
90,0
109,0
131,0
184,0
309,0
440,0
620,0
842,0

148,0
178,0
221,0

AWG-No.
16
16
16
16
16
16
16
16
16

14
14
14

Dimensions and specifications may be changed without prior notice. (RA04)

A 80

Masters: 14028 - ProductGroupID: PG1501 - Layout: L104_1 - Umbruch:

OZ-BL-CY

outer jacket blue, intrinsic safety, flexible, EMC-preferred type,

meter marking

Technical data

Cable structure

Properties

Control cable, special PVC with blue outer


jacket for hazardous areas to hazard type
-i- (=intrinsically safe)
For intrinsically safe installation according
to DINEN60079-14 and IEC60079-14
section12.2.2. (VDE0165 part1)
Temperature range
flexing -5C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance
core/core approx. 140 nF/km
core/screen approx. 187 nF/km
Inductance approx. 0,68 mH/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Core insulation of special PVCZ7225
Black cores with white continuous figure
imprint to DINVDE0293 without earth core
Cores stranded in layers with optimal
lay-length
Core wrapping of plastic foil
Braiding, tinned copper wire screening,
approx. 85% coverage
Special PVC outer sheath TM2, to
DINVDE0281 part1 and HD21.1
Colour blue (RAL5015)
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations.
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
For underground laying use NYY with blue
outer sheath.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Instrumentation cable RE-2Y(St)Yv with blue
outer jacket see catalog part B.

Application
For hazardous areas the cables with special marking (blue) (hazard type-i-) used as flexible control and measuring cables to meet the
requirements for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Those cables
are not suitable for underground laying.
The copper braided screening ensures the transmission of data signals and free from interference.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
14028
14029
14030
14031
14088
14032
14033
14034
14035
14036
14037
14038
14039
14040

14041
14042
14043
14044
14045
14046
14047

No.cores x
cross-sec.
mm
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
8x0,75
10x0,75
12x0,75
18x0,75
20x0,75
25x0,75
30x0,75
34x0,75
41x0,75

2x1
3x1
4x1
5x1
7x1
12x1
18x1

Outer
app. mm
6,1
6,4
6,9
7,4
8,6
9,4
10,2
10,4
12,4
12,9
15,1
15,6
16,9
18,3

6,4
6,7
7,3
7,8
9,1
11,2
13,2

Cop.
weight
kg / km
40,0
52,0
60,0
71,0
91,0
110,0
137,0
142,0
212,0
238,0
281,0
320,0
345,0
400,0

50,0
60,0
71,0
88,0
111,0
184,0
260,0

Weight
app.
kg / km
59,0
66,0
77,0
93,0
130,0
145,0
180,0
202,0
292,0
362,0
415,0
486,0
523,0
680,0

65,0
81,0
98,0
127,0
158,0
260,0
380,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA04)

A 81

18
18
18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17

Part No.
14048
14049

14050
14051
14052
14053
14054
14055
14056
14057
14058
14059

No.cores x
cross-sec.
mm
25x1
34x1

2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
12x1,5
18x1,5
25x1,5
30x1,5
34x1,5

Outer
app. mm
16,2
18,0

6,8
7,3
8,1
8,9
10,5
12,8
15,2
18,5
19,0
20,8

Cop.
weight
kg / km
349,0
486,0

63,0
80,0
97,0
119,0
147,0
267,0
374,0
526,0
555,0
629,0

Weight
app.
kg / km
534,0
741,0

88,0
100,0
126,0
160,0
208,0
338,0
479,0
705,0
830,0
900,0

AWG-No.
17
17

16
16
16
16
16
16
16
16
16
16

Masters: 14077 - ProductGroupID: PG1501 - Layout: L105_1 - Umbruch:

OB-BL-PAAR-CY

outer jacket blue, intrinsic safety, EMC-preferred type,

meter marking

Technical data

Cable structure

Properties

Special PVC control cable with blue outer


jacket for hazardous areas to hazard type
-i- for intrinsically safe installation according
to DINEN60079-14 and IEC60079-14
section12.2.2. (VDE0165 part1)
Conductor resistance
at 0,5 mm37,8 Ohm/km
at 0,75 mm25,3 Ohm/km
Temperature range
flexing -5C to +80C
fixed installation -30C to +80C
Nominal voltage 900 V
(not for power installation)
Test voltage
core/core 2000 V
core/screen 1000 V
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance
core/core approx. 105 nF/km
core/screen approx. 145 nF/km
Inductance
approx. 0,68 mH/km
Characteristic impedance
approx. 80 Ohm
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Special PVC core insulation YI2, to
DINVDE0207 part4
Cores colour coded according to DIN47100
Cores twisted in pairs
Pairs stranded in layers with optimal
lay-length
Foil taped
Tinned copper braided screening, approx.
80% coverage
Special PVC outer sheath YM2, to
DINVDE0207 part5
Colour blue RAL5015
with meter marking, change-over in 2009

Extensively oil resistant


Chemical Resistance - see table Technical
Informations
PVC self-extinguishing and flame retardant
according to VDE 0482-332-1-2, DIN EN
60332-1-2/ IEC60332-1 (equivalent
DINVDE0472 part804 test methodB)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Instrumentation cable RE-2Y(St)Yv with blue
outer jacket see catalog part B.

Application
For hazardous areas this flexible control cable has been constructed for closed circuit systems in accordance with VDE 0165 part 1, part
12.2.2.6, which covers the requirements for the special marking (blue) of this type (hazard type -i-).
The paired construction and the copper screening afford a good protection against electrical interference and ensure the transmission of
data signals.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
14077
14078
14079
14080
14081
14082
14083
14084
14085
14086
14087

No.pairs x
cross-sec.
mm
2 x 2 x 0,5
3 x 2 x 0,5
4 x 2 x 0,5
6 x 2 x 0,5
8 x 2 x 0,5
10 x 2 x 0,5
12 x 2 x 0,5
16 x 2 x 0,5
20 x 2 x 0,5
24 x 2 x 0,5
25 x 2 x 0,5

Outer
ca. mm
8,0
8,4
9,1
10,7
13,0
14,2
14,4
17,7
19,2
20,7
20,9

Cop.
weight
kg / km
47,0
67,0
80,0
108,0
129,0
172,0
235,0
301,0
343,0
394,0
406,0

Weight
ca. kg /
km
89,0
104,0
126,0
171,0
251,0
282,0
261,0
445,0
525,0
590,0
622,0

AWG-No.

Part No.
20
20
20
20
20
20
20
20
20
20
20

14089
14090
14091
14092
14093
14094
14095
14096
14097
14098
14099

No.pairs x
cross-sec.
mm
2 x 2 x 0,75
3 x 2 x 0,75
4 x 2 x 0,75
6 x 2 x 0,75
8 x 2 x 0,75
10 x 2 x 0,75
12 x 2 x 0,75
16 x 2 x 0,75
20 x 2 x 0,75
24 x 2 x 0,75
25 x 2 x 0,75

Outer
ca. mm
8,7
9,2
10,0
11,1
14,6
16,0
16,4
20,0
21,6
24,3
24,4

Cop.
weight
kg / km
60,0
80,0
110,0
142,0
200,0
238,0
270,0
342,0
369,0
451,0
461,0

Weight
ca. kg /
km
105,0
128,0
156,0
216,0
309,0
355,0
405,0
560,0
671,0
795,0
803,0

AWG-No.
18
18
18
18
18
18
18
18
18
18
18

Dimensions and specifications may be changed without prior notice. (RA04)

A 82

BIOFLEX-500-JZ
BIOFLEX-500-JZ-C
KOMPOFLEX JZ-500
KOMPOFLEX JZ-501-C
Photo: FUCHS DEA SCHMIERSTOFFE GMBH & Co. KG

Bio-Oil and microbial resistant Cables


We have joined forces with large scale farmers
and operators of biofuel plants to develop a
tailor-made product the new BIOFLEX-500.

wires from HELUKABEL. Specially modied polymers are used here for the core insulation and
the jacket materials.

HELUKABEL has accordingly matched and extended the range of products from its plant in
Windsbach. Special control cables and wires have
been developed which are not only friendly on
the environment, abrasion-resistant and can be
recycled, they are also resistant to bio-oils. These
are the special BIOFLEX-500-control cables and

In the laboratory, these special compounds have


been subjected to extreme testing according to
VDMA requirements and VDE specications. The
suitability of these compounds has been assessed
by endurance testing to demonstrate the longterm resistance to bio-oils.

A 83

31472-00e-A083.indd 114

03.04.2009 7:38:45 Uhr

Masters: 25620 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

BIOFLEX-500-JZ

Bio-fuel resistant, abrasion resistant, recyclable environment

friendly, bio-oil resistant1), meter marking

Technical data

Cable structure

Properties

Bio-oil resistant, abrasion resistant special


control cable in adapted to
DINVDE0245,0281
Temperature range
flexing -20C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 15x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Special polymer core insulation
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special outher sheath, polymer compound
Colour dark green
with meter marking, change-over in 2009

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
BIOFLEX JZ-500-C, seepageA85

Resistant to
Bio-fuel (diesel and petrol), highly resistant
to biologically decomposable oils, Oxygene,
Ozone, Hydrolysis and Microbes
Low adhesion

Note

Application
HELUKABEL BIOFLEX-500 is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance to
Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as in the steel
industry for difficult and problem areas. The high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying.
) For the critical applications we advise for consultation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
25620
25621
25622
25623
25624
25625
25626
25627
25628
25629

25630
25631
25632
25633
25634
25635
25636
25637
25638
25639
25640
25641

25642
25643
25644
25645
25646
25647
25648
25649
25650
25651
25652
25653

25654
25655
25656
25657
25658
25659

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
25G0,5

2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
18G0,75
25G0,75
41G0,75
42G0,75

2x1
3G1
4G1
5G1
7G1
10G1
12G1
14G1
18G1
25G1
41G1
42G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
10G1,5

Outer
app. mm
5,4
5,9
6,3
6,9
7,8
9,6
10,0
10,3
11,5
13,6

5,4
6,2
6,7
7,3
8,8
10,5
11,0
11,4
12,6
15,2
18,0
18,5

6,6
7,0
7,6
8,2
9,6
11,6
12,0
13,2
14,5
17,6
21,1
21,5

7,2
7,6
8,2
9,0
10,7
13,0

Cop.
weight
kg / km
9,6
14,4
19,0
24,0
33,6
48,0
58,0
67,0
86,0
120,0

14,4
21,6
29,0
36,0
50,0
72,0
86,0
101,0
130,0
180,0
296,0
310,0

19,0
29,0
38,0
48,0
67,0
96,0
115,0
134,0
173,0
240,0
394,0
403,0

29,0
43,0
58,0
72,0
101,0
144,0

Weight
app.
kg / km
45,0
55,0
65,0
75,0
90,0
120,0
135,0
170,0
205,0
270,0

44,0
53,0
64,0
76,0
96,0
140,0
170,0
202,0
260,0
282,0
600,0
620,0

53,0
63,0
75,0
89,0
115,0
166,0
201,0
230,0
289,0
380,0
720,0
740,0

68,0
87,0
106,0
131,0
173,0
245,0

AWG-No.
20
20
20
20
20
20
20
20
20
20

18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16

Part No.
25660
25661
25662
25663
25664

25665
25666
25667
25668
25669
25670
25671
25672

25673
25674
25675
25676

25677
25678
25679

25680
25681
25682

25683
25684

25685

25686

25687

25688

25689

25690

No.cores x
cross-sec.
mm
12G1,5
14G1,5
18G1,5
25G1,5
42G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

2x4
3G4
4G4
5G4

3G6
4G6
5G6

3G10
4G10
5G10

4G16
5G16

4G25

4G35

4G50

4G70

4G95

4G120

Outer
app. mm
13,4
14,5
16,0
19,5
23,8

8,6
9,3
10,3
11,5
13,4
17,0
20,0
24,1

10,4
11,2
12,5
13,8

13,0
14,7
16,0

16,7
18,3
20,5

21,1
23,6

29,4

32,8

38,9

44,7

59,6

64,5

Cop.
weight
kg / km
173,0
202,0
259,0
360,0
605,0

48,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0

77,0
115,0
154,0
192,0

173,0
230,0
288,0

288,0
384,0
480,0

614,0
768,0

960,0

1344,0

1920,0

2688,0

3648,0

4608,0

Weight
app.
kg / km
293,0
347,0
454,0
641,0
1100,0

110,0
146,0
183,0
222,0
293,0
512,0
740,0
940,0

147,0
228,0
291,0
355,0

362,0
468,0
570,0

555,0
720,0
894,0

1063,0
1400,0

1590,0

2200,0

2400,0

4400,0

6000,0

7400,0

AWG-No.
16
16
16
16
16

14
14
14
14
14
14
14
14

12
12
12
12

10
10
10

8
8
8

6
6

4

2

1

2/0

3/0

4/0

Dimensions and specifications may be changed without prior notice. (RA05)

A 84

Masters: 25691 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

BIOFLEX-500-JZ-C

Bio-fuel resistant, abrasion resistant, recyclable

environmentfriendly, bio-oilresistant1), Cu-screened, EMC-preferred type, meter marking

Technical data

Cable structure

Bio-oil resistant, abrasion resistant special


control cable in adapted to
DINVDE0245,0281
Temperature range
flexing -20C to +80C
fixed installation -40C to +80C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 20x cable
fixed installation 6x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106cJ/kg (up to 100 Mrad)

Bare copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Special polymer core insulation
Black cores with continuous white figure
imprint to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Special inner sheath
Screen of Cu braid, tinned coverage approx.
85%
Fleece separator, ensure good dismantling
ability
Special outher sheath, polymer compound
Colour dark green
with meter marking, change-over in 2009

Properties

Resistant to
Bio-fuel (diesel and petrol), highly resistant
to biologically decomposable oils, Oxygene,
Ozone, Hydrolysis and Microbes
Low adhesion

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
BIOFLEX JZ-500, seepageA84

Application
HELUKABEL BIOFLEX-500 C is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance
to Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as in the
steel industry for difficult and problem areas. The inner sheaths of those cables raise the mecanical stress. The high flexibility of this cable
type makes it quick and easy to install. Suitable for outdoor lying. These screened cables are particularly suitable for the interference-free
transmission in instrumentation and control engineering applications (electromagnetic compatibility). ) For the critical applications we advise
for consultation.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
25691
25692
25693
25694
25695
25696
25697
25698
25699
25700

25701
25702
25703
25704
25705
25706
25707
25708
25709
25710
25711
25712

25713
25714
25715
25716
25717
25718
25719

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
10G0,5
12G0,5
14G0,5
18G0,5
25G0,5

2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
10G0,75
12G0,75
14G0,75
18G0,75
25G0,75
41G0,75
42G0,75

2x1
3G1
4G1
5G1
7G1
10G1
12G1

Outer
app. mm
6,6
7,1
7,6
8,2
9,4
11,2
11,3
11,9
12,9
15,9

7,2
7,7
8,2
8,8
10,1
12,2
12,3
13,0
14,6
17,8
21,5
22,0

8,1
8,5
9,0
9,9
11,6
14,0
14,4

Cop.
weight
kg / km
41,0
45,0
54,0
66,0
79,0
107,0
137,0
142,0
156,0
250,0

46,0
57,0
63,0
76,0
100,0
140,0
175,0
190,0
240,0
306,0
403,0
410,0

54,0
64,0
76,0
89,0
114,0
156,0
186,0

Weight
app.
kg / km
68,0
84,0
95,0
107,0
135,0
170,0
195,0
222,0
278,0
406,0

88,0
98,0
112,0
130,0
185,0
270,0
294,0
317,0
357,0
510,0
951,0
975,0

98,0
102,0
145,0
170,0
220,0
330,0
350,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA05)

A 85

20
20
20
20
20
20
20
20
20
20

18
18
18
18
18
18
18
18
18
18
18
18

17
17
17
17
17
17
17

Part No.
25720
25721
25722
25723
25724

25725
25726
25727
25728
25729
25730
25731
25732
25733
25734
25735
25736

25737
25738
25739
25740
25741
25742

25743
25744
25745
25746

No.cores x
cross-sec.
mm
14G1
18G1
25G1
41G1
42G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
10G1,5
12G1,5
14G1,5
18G1,5
25G1,5
41G1,5
42G1,5

2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5

2x4
3G4
4G4
5G4

Outer
app. mm
15,0
17,0
20,6
25,0
25,5

8,5
8,9
9,7
10,8
12,5
15,1
15,5
16,1
18,6
22,1
27,2
27,5

10,6
11,1
12,1
13,2
15,9
19,5

12,6
13,4
15,0
16,4

Cop.
weight
kg / km
198,0
284,0
387,0
578,0
590,0

64,0
82,0
99,0
123,0
148,0
198,0
274,0
294,0
386,0
531,0
840,0
890,0

110,0
148,0
169,0
220,0
284,0
470,0

124,0
178,0
234,0
284,0

Weight
app.
kg / km
402,0
515,0
690,0
1070,0
1096,0

130,0
152,0
167,0
203,0
305,0
422,0
435,0
480,0
642,0
803,0
1360,0
1375,0

180,0
215,0
268,0
349,0
406,0
720,0

300,0
340,0
408,0
504,0

AWG-No.
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16

14
14
14
14
14
14

12
12
12
12
Continuation

Masters: 25691 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

BIOFLEX-500-JZ-C

Bio-fuel resistant, abrasion resistant, recyclable

environmentfriendly, bio-oilresistant1), Cu-screened, EMC-preferred type, meter marking


Part No.
25747
25748
25749

25750
25751
25752

25753
25754

No.cores x
cross-sec.
mm
3G6
4G6
5G6

3G10
4G10
5G10

4G16
5G16

Outer
app. mm
15,2
17,0
18,6

19,5
21,5
23,9

24,6
27,3

Cop.
weight
kg / km
245,0
316,0
442,0

367,0
549,0
604,0

807,0
940,0

Weight
app.
kg / km
453,0
560,0
700,0

750,0
1023,0
1114,0

1385,0
1550,0

AWG-No.
10
10
10

8
8
8

6
6

Part No.
25755

25756

25757

25758

25759

25760

No.cores x
cross-sec.
mm
4G25

4G35

4G50

4G70

4G95

4G120

Outer
app. mm
30,6

36,9

41,3

48,8

61,8

65,7

Cop.
weight
kg / km
1169,0

1680,0

2370,0

3257,0

4060,0

5231,0

Weight
app.
kg / km
1894,0

2395,0

3312,0

4605,0

6055,0

7318,0

AWG-No.
4

2

1

2/0

3/0

4/0

Dimensions and specifications may be changed without prior notice. (RA05)

A 86

Masters: 26125 - ProductGroupID: PG1501 - Layout: L100_1 - Umbruch:

KOMPOFLEX JZ-500 halogen-free, microbes resistant, low adhesion,


meter marking

Technical data

Cable structure

Properties

Microbes resistant, halogen-free special


control cable in adapted to DINVDE0281
part13 and EDINVDE0245
Temperature range
flexing -30C to + 90C
fixed installation -40C to +100C
Nominal voltage U0/U 300/500 V
Test voltage 3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Tinned copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Special thermoplastic polymer-core
insulation
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Outher sheath, special thermoplastic
polymer
Colour black (RAL9005)
with meter marking, change-over in 2009

Resistant to
UV-radiation, Oxygene, Ozone, Microbes,
Hydrofluoric acid, Hydrochloric acid and
diluted sulfuric acid
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Low adhesion

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
KOMPOFLEX JZ-500-C, seepageA88

Application
Extremly robust universal cable. This cable is specially installed in rubbish, sewage-treatment plants, composting works, animal stalls
and greenhouses. Suitable for installation for flexible use for medium mechanical, stresses with free movement without tensile stress or
forced movements in dry, moist and wet rooms as well as outside.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
26125
26126
26127
26128
26129
26130
26131
26132
26133
26135
26136
26137
26138
26139
26140
26141
26142
26143
26144
26145
26146
26147
26149
26150
26151
26152
26153
26154
26155
26156
26157
26158
26159
26160
26162
26163
26164
26165
26166
26167
26168
26169

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
20G0,5
25G0,5
34G0,5
42G0,5
50G0,5
61G0,5
2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
20G0,75
25G0,75
34G0,75
42G0,75
50G0,75
61G0,75
2x1
3G1
4G1
5G1
7G1
12G1
18G1
20G1
30G1
34G1
42G1
50G1
61G1
2x1,5
3G1,5
4G1,5

Outer
app. mm
4,8
5,1
5,7
6,2
7,4
9,1
10,7
11,2
13,0
14,5
15,8
17,3
19,4
5,2
5,5
6,2
6,8
8,1
9,9
11,9
12,6
14,5
16,4
17,6
19,8
20,9
5,5
6,0
6,6
7,2
8,6
10,7
12,7
13,5
16,0
17,4
18,9
21,0
22,2
6,3
6,7
7,3

Cop.
weight
kg / km
9,6
14,4
19,0
24,0
33,6
58,0
86,0
96,0
120,0
163,0
202,0
240,0
293,0
14,4
21,6
29,0
36,0
50,0
86,0
130,0
144,0
180,0
245,0
302,0
360,0
439,0
19,0
29,0
38,0
48,0
67,0
115,0
173,0
192,0
288,0
326,0
403,0
480,0
586,0
29,0
43,0
58,0

Weight
app.
kg / km
41,0
50,0
61,0
72,0
86,0
130,0
198,0
211,0
260,0
361,0
405,0
541,0
670,0
42,0
49,0
60,0
71,0
88,0
161,0
250,0
266,0
273,0
501,0
591,0
712,0
820,0
48,0
56,0
70,0
81,0
109,0
191,0
274,0
314,0
492,0
640,0
804,0
932,0
1102,0
60,0
79,0
98,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA05)

A 87

20
20
20
20
20
20
20
20
20
20
20
20
20
18
18
18
18
18
18
18
18
18
18
18
18
18
17
17
17
17
17
17
17
17
17
17
17
17
17
16
16
16

Part No.
26170
26171
26172
26173
26174
26175
26176
26177
26178
26179
26180
26181
26182
26183
26184
26185
26186
26187
26189
26190
26191
26192
26193
26195
26196
26197
26198
26199
26200
26201
26202
26204
26206
26208
26212
26215
26216

No.cores x
cross-sec.
mm
5G1,5
7G1,5
12G1,5
18G1,5
20G1,5
25G1,5
34G1,5
42G1,5
50G1,5
61G1,5
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5
3G4
4G4
5G4
7G4
12G4
3G6
4G6
5G6
7G6
3G10
4G10
5G10
7G10
4G16
7G16
4G25
4G35
4G50
5G50

Outer
app. mm
8,2
9,8
12,1
14,5
15,2
17,8
19,8
21,4
23,7
25,3
7,6
8,3
9,1
10,2
12,1
15,2
18,1
22,2
9,9
11,0
12,1
13,3
18,3
11,7
13,0
14,5
16,0
15,0
16,8
18,7
20,6
19,7
24,4
25,2
29,0
33,4
37,2

Cop.
weight
kg / km
72,0
101,0
173,0
259,0
288,0
360,0
490,0
605,0
720,0
878,0
48,0
72,0
96,0
120,0
168,0
288,0
432,0
600,0
115,0
154,0
192,0
269,0
461,0
173,0
230,0
288,0
403,0
288,0
384,0
480,0
672,0
614,0
1075,0
960,0
1344,0
1920,0
2400,0

Weight
app.
kg / km
112,0
159,0
280,0
420,0
480,0
604,0
812,0
1002,0
1240,0
1421,0
99,0
136,0
170,0
204,0
281,0
487,0
704,0
909,0
224,0
289,0
357,0
451,0
782,0
345,0
417,0
521,0
622,0
537,0
699,0
851,0
1102,0
1028,0
1772,0
1577,0
2097,0
2914,0
3919,0

AWG-No.
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
12
12
12
12
12
10
10
10
10
8
8
8
8
6
6
4
2
1
1

Masters: 26217 - ProductGroupID: PG1501 - Layout: L101-15_1 - Umbruch:

KOMPOFLEX JZ-500-C halogen-free, microbes resistant, Cu-screende,


EMC-preferred type, meter marking

Technical data

Cable structure

Properties

Screened microbes resistant, halogen-free


special control cable in adapted to
DINVDE0281 part13 and EDINVDE0245
Temperature range
flexing -30C to + 90C
fixed installation -40C to +100C
Nominal voltage U0/U 300/500 V
Test voltage
core/core 4000 V
core/screen 2000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Coupling resistance
max. 250 Ohm/km
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Tinned copper, fine wire conductors, bunch


stranded to DINVDE0295 cl.5, BS6360 cl.5
and IEC60228 cl.5
Special thermoplastic polymer core
insulation
Black cores with continuous white
numbering according to DINVDE0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-length
Inner-sheath to special thermoplastic
polymer
Screen of tinned cu braid, coverage approx.
85%
Outer sheath, special thermoplastic polymer
Colour black (RAL9005)
with meter marking, change-over in 2009

Resistant to
UV-radiation, Oxygene, Ozone, Microbes,
Hydrofluoric acid, Hydrochloric acid and
diluted sulfuric acid
Low adhesion
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note
G = with green-yellow earth core;
x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
KOMPOFLEX JZ-500, seepageA87

Application
Die mehr als robuste Universalleitung.
This cable is specially installed in rubbish, sewage-treatment plants, composting works, animal stalls and greenhouses. The inner sheaths of
those cables raise the mechanical stress. Suitable for installation for flexible use for medium mechanical, stresses with free movement
without tensile stress or forced movements in dry, moist and wet rooms as well as outside. The high flexibility of this cable type makes it
quick and easy to install.
This screened cable is ideal for use in data signal transmission free from interferences for measurement and control engineering technology.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.
Part No.
26217
26218
26219
26220
26221
26222
26223
26224
26225
26226
26227
26228
26229
26230

26231
26232
26233
26234
26235
26236
26237
26238
26239
26240
26241
26242
26243
26244

No.cores x
cross-sec.
mm
2x0,5
3G0,5
4G0,5
5G0,5
7G0,5
12G0,5
18G0,5
20G0,5
25G0,5
30G0,5
34G0,5
42G0,5
50G0,5
61G0,5

2x0,75
3G0,75
4G0,75
5G0,75
7G0,75
12G0,75
18G0,75
20G0,75
25G0,75
30G0,75
34G0,75
42G0,75
50G0,75
61G0,75

Outer
app. mm
6,9
7,2
7,8
8,3
9,5
11,3
13,1
13,8
15,7
16,0
17,4
18,9
20,9
22,9

7,6
7,8
8,3
9,1
10,4
12,5
14,3
15,2
17,6
18,1
19,5
20,9
23,2
25,0

Cop.
weight
kg / km
41,0
45,0
54,0
66,0
79,0
137,0
156,0
173,0
250,0
297,0
316,0
360,0
407,0
520,0

46,0
57,0
63,0
76,0
100,0
175,0
240,0
262,0
306,0
340,0
346,0
410,0
470,0
550,0

Weight
app.
kg / km
68,0
84,0
95,0
107,0
135,0
195,0
278,0
310,0
406,0
520,0
571,0
651,0
760,0
911,0

88,0
98,0
112,0
130,0
185,0
294,0
357,0
404,0
510,0
561,0
670,0
960,0
1104,0
1270,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA05)

20
20
20
20
20
20
20
20
20
20
20
20
20
20

18
18
18
18
18
18
18
18
18
18
18
18
18
18

Part No.
26245
26246
26247
26248
26249
26250
26251
26252
26253
26254
26255
26256
26257
26258

26259
26260
26261
26262
26263
26264
26265
26266
26267
26268
26269
26270
26271
26272

No.cores x
cross-sec.
mm
2x1
3G1
4G1
5G1
7G1
12G1
18G1
20G1
25G1
30G1
34G1
42G1
50G1
61G1

2x1,5
3G1,5
4G1,5
5G1,5
7G1,5
12G1,5
18G1,5
20G1,5
25G1,5
30G1,5
34G1,5
42G1,5
50G1,5
61G1,5

Outer
app. mm
7,9
8,2
8,9
9,5
11,0
13,1
15,4
16,0
18,3
18,8
20,3
21,8
24,0
26,2

8,4
9,0
9,6
10,5
12,1
14,9
17,1
18,0
20,7
21,1
22,7
24,4
26,8
29,6

Cop.
weight
kg / km
54,0
64,0
76,0
89,0
114,0
186,0
284,0
325,0
387,0
457,0
500,0
590,0
681,0
710,0

64,0
82,0
99,0
123,0
148,0
274,0
386,0
401,0
531,0
598,0
671,0
890,0
997,0
1120,0

Weight
app.
kg / km
98,0
102,0
145,0
171,0
210,0
330,0
488,0
545,0
690,0
770,0
811,0
996,0
1320,0
1480,0

130,0
154,0
165,0
197,0
305,0
435,0
642,0
718,0
803,0
961,0
1060,0
1300,0
1677,0
1971,0

AWG-No.
17
17
17
17
17
17
17
17
17
17
17
17
17
17

16
16
16
16
16
16
16
16
16
16
16
16
16
16
Continuation

A 88

Masters: 26217 - ProductGroupID: PG1501 - Layout: L101-15_1 - Umbruch:

KOMPOFLEX JZ-500-C halogen-free, microbes resistant, Cu-screende,


EMC-preferred type, meter marking
Part No.
26273
26274
26275
26276
26277
26278
26279
26280

26281
26282
26283
26284
26285
26286

26287
26288
26289
26290
26291

No.cores x
cross-sec.
mm
2x2,5
3G2,5
4G2,5
5G2,5
7G2,5
12G2,5
18G2,5
25G2,5

2x4
3G4
4G4
5G4
7G4
12G4

2x6
3G6
4G6
5G6
7G6

Outer
app. mm
10,0
10,7
11,4
12,5
15,0
18,0
21,2
25,5

11,6
12,3
13,4
14,8
16,2
21,8

13,5
14,2
15,6
17,0
18,7

Cop.
weight
kg / km
110,0
148,0
169,0
220,0
284,0
470,0
572,0
740,0

124,0
178,0
234,0
284,0
321,0
581,0

176,0
245,0
316,0
442,0
530,0

Weight
app.
kg / km
180,0
215,0
268,0
349,0
404,0
710,0
891,0
1104,0

300,0
340,0
408,0
504,0
640,0
894,0

391,0
453,0
560,0
680,0
891,0

AWG-No.

Dimensions and specifications may be changed without prior notice. (RA05)

A 89

14
14
14
14
14
14
14
14

12
12
12
12
12
12

10
10
10
10
10

Part No.
26292
26293
26294
26295

26296
26297
26298
26299

26300
26301
26302

26303
26304

26305
26306

No.cores x
cross-sec.
mm
3G10
4G10
5G10
7G10

3G16
4G16
5G16
7G16

3G25
4G25
5G25

4G35
5G35

4G50
5G50

Outer
app. mm
17,8
19,7
21,6
24,0

20,7
22,6
25,2
27,6

26,0
28,9
31,8

33,4
37,2

38,2
43,0

Cop.
weight
kg / km
367,0
549,0
604,0
820,0

653,0
807,0
940,0
1345,0

920,0
1169,0
1420,0

1680,0
2020,0

2370,0
2880,0

Weight
app.
kg / km
730,0
1004,0
1170,0
1405,0

894,0
1311,0
1550,0
1820,0

1430,0
1894,0
2272,0

2310,0
2740,0

3270,0
4080,0

AWG-No.
8
8
8
8

6
6
6
6

4
4
4

2
2

1
1

Das könnte Ihnen auch gefallen