Sie sind auf Seite 1von 38

VVS/VVP Series Vane Pumps

Technical Catalog

Variable Displacement,
For Industrial
Applications

Contents

Introduction................................................................................................................................................................. Page 3
Sectional Views and Functional Symbols................................................................................................................ Page 4
Series VVS Pumps
Model Code.............................................................................................................................................. Page 5
Technical Data........................................................................................................................................... Page 6
Performance Characteristics
VVS0............................................................................................................................................... Page 7
VVS1............................................................................................................................................... Page 8
VVS2............................................................................................................................................... Page 9
VVS3............................................................................................................................................... Page 10
Installation Dimensions
VVS0............................................................................................................................................... Page 11
VVS1............................................................................................................................................... Page 12
VVS2 & VVS3.................................................................................................................................. Page 13
Series VVP Pumps
Model Code.............................................................................................................................................. Page 15
Technical Data........................................................................................................................................... Page 16
Controls
Pressure Regulation........................................................................................................................Page 17
Load Sensing and Pressure Regulation.......................................................................................... Page 18
Pressure Regulation with Torque Sensing......................................................................................Page 20
Performance Characteristics
VVP1............................................................................................................................................... Page 21
VVP2............................................................................................................................................... Page 22
VVP3............................................................................................................................................... Page 23
Installation Dimensions
VVP1............................................................................................................................................... Page 24
VVP2 & VVP3.................................................................................................................................. Page 25
Series VVS and VVP Pumps
Installation Dimensions - Base Mounted Pumps......................................................................................Page 27
Combined Pumps
Pump Combinations................................................................................................................................. Page 28
Torque Requirements............................................................................................................................... Page 30
Installation Dimensions.............................................................................................................................Page 31
Key Lock Adjustment..................................................................................................................................................Page 35
Mounting, Shaft and Port Dimensions..................................................................................................................... Page 36
Installation Instructions..............................................................................................................................................Page 37

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Introduction

Description

(1) Body

Features and Benefits

Maximum displacements to
100 cm3/r (6.1 in3/r).

(2) One-piece shaft and rotor

Maximum pressures to 160 bar


(2300 psi).

(4) Pressure ring that changes


the eccentricity and
therefore the displacement
of the pump, at hydrostatic
axial compensation

Long pump life resulting from


manufacturing material characteristics, hydrodynamic
lubrication of bearings, and
hydrostatic balancing of distribution plates.

Vickers variable displacement


vane pumps are available in
four nominal sizes (0-1-2-3) and
are divided into three displacements. Each size, while retaining the same pump body, is
available in two versions: low
pressure VVS (100 bar, 1500
psi) with mechanical pressure
regulator, and high pressure
VVP (160 bar, 2300 psi) with
hydraulic pressure regulator.
The rotor shaft of Vickers
pumps is pre-arranged for
mounting an additional pump.
By removing the rear cover, the
secondary pump can be easily
attached (see items A and B on
page 4). Combining standard
pumps eliminates the need for
many special application
pumps.
As shown in the cross-sectional
views, pumps consist of:
Modular Construction

(3) Vanes

(5) Pressure plate stator to


provide the passage of oil
from the suction port to
the pressure port
(6) Guide block balancing
adjustment screw
(7) Displacement adjustment
piston that regulates the
maximum pressure
compensated flow
(8) Maximum volume
adjustment screw (optional
feature - see model code
pages 5 and 15).

Quiet pump operation from


55 to 73 dB(A).
Simplifies hydraulic circuit by
eliminating maximum pressure relief valves and heat
exchangers. Pumps can be
supplied with various pressure regulators to control the
maximum system pressure.
Standard ISO and SAE
mountings.
Combinations of standard
pumps provide flexibility and
cost effective pump packages.

(9) Pressure regulator


(10) Pressure regulator
adjustment

VVS mechanical
pressure compensator
VVP hydraulic pressure compensator
for pressure and flow controls

Basic pump

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Sections and
Symbols

VVP Pump
See description on page 3.

VVS Pump
See description on page 3.

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Model Code
VVS Series

Variable Vane Pump

2
0

3
06
10
12
16
20
25
32
40
50
63
80
100

6.3, 10, 12.5 cm3/r


Max. pressure 150 bar
(2200 psi)
16, 20, 25 cm3/r
Max. pressure 100 bar
(1500 psi)
31.5, 40, 50 cm3/r
Max. pressure 100 bar
(1500 psi)
63, 80, 100 cm3/r
Max. pressure 80 bar
(1200 psi)

Nominal Size /
Geometric Displacement

6.3 cm /r (0.38 in /r)


10 cm3/r (0.61 in3/r)
12.5 cm3/r (0.76 in3/r)
16 cm3/r (0.98 in3/r)
20 cm3/r (1.22 in3/r)
25 cm3/r (1.53 in3/r)
31.5 cm3/r (1.92 in3/r)
40 cm3/r (2.44 in3/r)
50 cm3/r (3.05 in3/r)
63 cm3/r (3.84 in3/r)
80 cm3/r (4.88 in3/r)
100 cm3/r (6.10 in3/r)
3

Mounting Flange / Port Connections

Port connections
G (BSPF) thread.

RF

SAE 4-bolt flange with


metric mounting bolts

Frame Size / Max.


Pressure

5
Code Frame Size
R
Size 0 or 1

PS

PF

PX

Mounting flange
ISO 3019/2 with straight
keyed shaft (size 0 is only
available as a single or
secondary pump)
Size 2 or 3
ISO 3019/2 with straight
keyed shaft
Size 0
ISO 3019/2 with straight
keyed shaft (for size
0 pumps only). Size 0 is
only available as a single
or secondary pump.
Size 1
SAE B 4-bolt with straight
keyed shaft (for size 1
pumps only)
Size 2 or 3
SAE C 2-bolt with straight
keyed shaft (only available
on a primary or single
pump)
Size 2 or 3
ISO 3019/2 with straight
keyed shaft (available
only on secondary pump)
Sizes 1, 2 or 3 Base plate mounting
(available only as
single pump)

7
4

Adjust. Max.
Displacement Stop

SAE UNF thread.

SAE 4-bolt flange with


UNC mounting bolts

SAE 4-bolt flange with


UNC mounting bolts

M
E

Pressure Control

10

Standard pressure
compensator

Control Pressure Setting

15-50 bar (215-700 psi)


(all frame sizes)
30-80 bar (430-1200 psi)
(frame size 3)
30-100 bar (430-1500 psi)
(frame sizes 0, 1 and 2)
80-150 bar
(1200-2200 psi)
(frame size 0)

O-ring sealed
11

Rotation Viewed From


Shaft End

9
C

Note: See page 36 for detailed dimensional listing for mounting flanges,
shafts and ports.
6

Pump Design Number


8
30 All models except
Subject to change. Installation
dimensions remain unaltered for
designs *0-*9.

Right hand
(clockwise) only

W
KL

12

Adjustment Device

Screw with locknut


Screw with key lock

Control Design Number

10 For all models.


Subject to change. Installation
dimensions remain unaltered for
designs 10-19.

Fluid Compatibility

Mineral oil
Phosphate esters

13

Special Features Suffix

S With stop
(Omit if not required.)

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Technical Data
VVS Series

Nominal size
Displacement according to ISO 3662 - cm3/r (in3/r)

Actual displacement - cm3/r (in3/r)

Mounting flange type (See model code, page 5.)

Maximum working pressure - bar (psi)


Allowed maximum drain port pressure - bar (psi)
Inlet pressure (absolute) - bar (psi)
Speed range - r/min
Rotation direction (viewed from shaft end)
Loads on drive shaft
Maximum torque on primary shaft - Nm (lbf-in)
(See pages 28 and 30 for torque requirements of
combined pumps.)
Hydraulic fluid

Size 0
6.3 (0.384)
10 (0.610)
12.5 (0.763)
6.9 (0.421)
11 (0.671)
13.1 (0.799)
ISO 3019/2
4-bolt
150 (2200)

110 (974)

Size 1
Size 2
Size 3
16 (0.976)
31.5 (1.922)
63
(3.844)
20 (1.220)
40 (2.441)
80
(4.882)
25 (1.526)
50 (3.051)
100 (6.102)
17.9 (1.092)
34.5 (2.105)
69
(4.211)
22.1 (1.349)
42.8 (2.612)
86.2 (5.260)
26.9 (1.642)
53.1 (3.240)
105.5 (6.438)
ISO 3019/2
ISO 3019/2
ISO 3019/2
4-bolt
SAE C 2-bolt SAE C 2-bolt
Base plate
Base plate
Base plate
100 (1500)
100 (1500)
80 (1200)
1 (14.5)
0.8-1.5[11.6-21.8]
800 to 1800
Right-hand (clockwise)
No radial or axial loads allowed
197 (1744)

400 (3540)

740 (6550)

Mineral oil - HM according to ISO 6743/4 - HLP according


to DIN 51524/2
Organic ester HFD-V according to ISO 6743/4 (QUINTOLUTSRIC N822-300)

Viscosity range at working temperature - mm2/s (cSt)


23 to 68
Recommended viscosity - mm2/s (cSt) at 50C (122F)
32
Viscosity index
100 minimum
Fluid temperature range - C (F)
-10/+50 [14/122]
Maximum fluid contamination level
Class 9 per NAS 1638, or class 18/16/13 per ISO 4406
Weight - kg (lb)
6.5 (14.3)
12 (26.5)
32 (70.5)
44 (97)
In case of different operating conditions, contact Eaton Hydraulics.

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Performance
Characteristics
VVS0

Performance with:

Power consumption with


maximum flow

Speed 1450 r/min


Oil per ISO 6743/4

Power consumption with zero


flow setting

Viscosity 32 mm2/s (cSt)


Temperature 50C (122F)

VVS0-06, -10, -12


Values established with zero flow setting

VVS0-06
14 (3.70)

8 (2.11)

4 (5.36)

6 (1.59)

3 (4.02)

4 (1.06)

2 (2.68)

2 (0.53)

1 (1.34)
0

Input power - kW (hp)

Flow - L/min (USgpm)

10 (2.64)

drainage l/min (USgpm)

2.5 (0.66)

12 (3.17)

6-10-12
2 (0.53)
1.5 (0.40)
1 (0.26)
0.5 (0.13)
0

25
50
75
100
125
150
(350) (700) (1100) (1500) (1850) (2200)
Operating pressure - bar (psi)

75
(1088)

100
(1450)

125
150
(1813) (2176)

VVS0-06, -10, -12


Maximum noise level measured with sound-level meter placed at
1 meter [39.37] from pump, flexible coupling.

21 (5.55)

68

12 (3.17)

6 (8.05)

9 (2.38)

4.5 (6.03)

6 (1.59)

3 (4.02)

3 (0.79)

1.5 (2.01)
0

6-10-12

66
64
dB(A)

15 (3.96)

Input power - kW (hp)

18 (4.76)
Flow - L/min (USgpm)

50
(725)

pressure bar (psi)

VVS0-10

62
60
58
56

25
50
75
100
125
150
(350) (700) (1100) (1500) (1850) (2200)
Operating pressure - bar (psi)

VVS0-12

25
(363)

50
75
100
(725) (1088) (1450)
pressure bar (psi)

125
(1813)

150
(2176)

VVS0-06, -10, -12


Response time and pressure peak

21 (5.55)

12 (3.17)

6 (8.05)

9 (2.38)

4.5 (6.03)

6 (1.59)

3 (4.02)

3 (0.79)

1.5 (2.01)
0

25
50
75
100
125
150
(350) (700) (1100) (1500) (1850) (2200)
Operating pressure - bar (psi)

250 (3626)
pressure bar (psi)

15 (3.96)

Input power - kW (hp)

18 (4.76)
Flow - L/min (USgpm)

25
(363)

6-10-12

200 (2901)
150 (2176)
100 (1450)
50 (7250
0
time ms

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

50 ms

Performance
Characteristics
VVS1

Performance with:

Power consumption with


maximum flow

Speed 1450 r/min


Oil per ISO 6743/4

Power consumption with zero


flow setting

Viscosity 32 mm2/s (cSt)


Temperature 50C (122F)

VVS1-16, -20, -25


Values established with zero flow setting

VVS1-16

20 (5.28)

6 (8.05)
5 (6.71)
4 (5.36)
3 (4.02)
2 (2.68)
1 (1.34)

15 (3.96)
10 (2.64)
5 (1.32)
0

20
40
60
80
(300)
(600)
(900)
(1200)
Operating pressure - bar (psi)

1 (0.26)
0.5 (0.13)

20
(290)

40
(580)

60
(870)

80
(1160)

100
(1450)

pressure bar (psi)

VVS1-16, -20, -25


Maximum noise level measured with sound-level meter placed at
1 meter [39.37] from pump, flexible coupling.
70
7 (9.39)
6 (8.05)
5 (6.71)
4 (5.36)
3 (4.02)
2 (2.68)
1 (1.34)

25 (6.60)
20 (5.28)
15 (3.96)
10 (2.64)
0

40
60
80
20
(600)
(900)
(1200)
(300)
Operating pressure - bar (psi)

16-20-25

68
66
dB(A)

30 (7.93)

Input power - kW (hp)

64
62
60
58

100
(1500)

VVS1-25

20
(290)

40
60
(580)
(870)
pressure bar (psi)

80
(1160)

100
(1450)

VVS1-16, -20, -25


Response time and pressure peak

40 (10.57)

20 (5.28)
10 (2.64)

40
60
80
20
(600)
(900)
(1200)
(300)
Operating pressure - bar (psi)

100
(1500)

250 (3626)
Input power - kW (hp)

8 (10.73)
7 (9.39)
6 (8.05)
5 (6.71)
4 (5.36)
3 (4.02)
2 (2.68)
1 (1.34)

30 (7.93)

pressure bar (psi)

Flow - L/min (USgpm)

1.5 (0.40)

35 (9.25)

Flow - L/min (USgpm)

16-20-25

2 (0.53)

100
(1500)

VVS1-20

drainage l/min (USgpm)

2.5 (0.66)

25 (6.60)

Input power - kW (hp)

Flow - L/min (USgpm)

30 (7.93)

16-20-25
200 (2901)
150 (2176)
100 (1450)
50 (725)
0

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

time ms

50 ms

Performance
Characteristics
VVS2

Performance with:

Power consumption with


maximum flow

Speed 1450 r/min


Oil per ISO 6743/4

Power consumption with zero


flow setting

Viscosity 32 mm2/s (cSt)


Temperature 50C (122F)

VVS2-32, -40, -50


Values established with zero flow setting

VVS2-32
60 (15.85)

10 (13.41)

30 (7.93)

8 (10.73)

20 (5.28)

6 (8.05)
4 (5.36)

10 (2.64)

2 (2.68)
0

20
40
60
80
(300)
(600)
(900)
(1200)
Operating pressure - bar (psi)

32-40-50

3 (0.79)
2.25 (0.59)
1.5 (0.40)
0.75 (0.20)
0

100
(1500)

20
(290)

40
(580)

60
(870)

80
(1160)

100
(1450)

pressure bar (psi)

VVS2-32, -40, -50


Maximum noise level measured with sound-level meter placed at
1 meter [39.37] from pump, flexible coupling.

VVS2-40
70 (18.49)

72

14 (18.77)
12 (16.09)

50 (13.21)

10 (13.41)

40 (10.57)

8 (10.73)
6 (8.05)

30 (7.93)

4 (5.36)
20 (5.28)

2 (2.68)
0

20
40
60
80
(300)
(600)
(900)
(1200)
Operating pressure - bar (psi)

32-40-50

70
68
dB(A)

60 (15.85)

Input power - kW (hp)

Flow - L/min (USgpm)

drainage l/min (USgpm)

12 (16.09)

40 (10.57)

Input power - kW (hp)

Flow - L/min (USgpm)

3.75 (0.99)
50 (13.21)

66
64
62
60

100
(1500)

VVS2-50

20
(290)

40
60
(580)
(870)
pressure bar (psi)

80
(1160)

100
(1450)

VVS2-32, -40, -50


Response time and pressure peak

90 (23.78)

60 (15.85)

14 (18.77)

45 (11.89)

11 (14.75)
8 (10.73)

30 (7.93)

5 (6.71)
15 (3.96)

2 (2.68)
0

40
60
80
20
(600)
(900)
(1200)
(300)
Operating pressure - bar (psi)

100
(1500)

pressure bar (psi)

17 (22.80)

Input power - kW (hp)

Flow - L/min (USgpm)

250 (3626)
75 (19.81)

32-40-50

200 (2901)
150 (2176)
100 (1450)
50 (725)
0
time ms

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

50 ms

Performance
Characteristics
VVS3

Performance with:

Power consumption with


maximum flow

Speed 1450 r/min


Oil per ISO 6743/4

Power consumption with zero


flow setting

Viscosity 32 mm2/s (cSt)


Temperature 50C (122F)

VVS3-63, -80, -100


Values established with zero flow setting

VVS3-63
120 (31.70)

15 (20.12)

60 (15.85)

12 (16.09)

40 (10.57)

9 (12.07)
6 (8.05)

20 (5.28)

3 (4.02)
0

20
35
50
65
(300)
(500)
(700)
(900)
Operating pressure - bar (psi)

63-80-100

4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0

80
(1200)

20
(290)

40
(580)

60
(870)

80
(1160)

pressure bar (psi)

VVS3-63, -80, -100


Maximum noise level measured with sound-level meter placed at
1 meter [39.37] from pump, flexible coupling.

VVS3-80
150 (39.63)

74
23 (30.84)

100 (26.42)

19 (25.48)

75 (19.81)

15 (20.12)
11 (14.75)

50 (13.21)

7 (9.39)
25 (6.60)

3 (4.02)

63-80-100

72
70
dB(A)

125 (33.03)

Input power - kW (hp)

Flow - L/min (USgpm)

drainage l/min (USgpm)

18 (24.14)
80 (21.13)

Input power - kW (hp)

Flow - L/min (USgpm)

5 (1.32)
100 (26.42)

68
66
64

20
35
50
65
(300)
(500)
(700)
(900)
Operating pressure - bar (psi)

80
(1200)

62
0

VVS3-100

60
(870)

80
(1160)

30 (40.23)
120 (31.70)

25 (33.53)

90 (23.76)

20 (26.82)

60 (15.85)

15 (20.12)
10 (13.41)

30 (7.93)

5 (6.71)
0

20
35
50
65
(300)
(500)
(700)
(900)
Operating pressure - bar (psi)

80
(1200)

pressure bar (psi)

260 (3771)

150 (39.63)

Input power - kW (hp)

Flow - L/min (USgpm)

40
(580)
pressure bar (psi)

VVS3-63, -80, -100


Response time and pressure peak

180 (47.55)

10

20
(290)

63-80-100

200 (2901)
140 (2031)
80 (1160)
20 (290)
0

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

time ms

50 ms

VVS0
With ISO
Mounting Flange
Installation Dimensions
in mm (in)
All mounting flange, port and
shaft options are listed on
page 36.

3rd angle
projection

30 [1.181] max.

C Control
With W Adjustment

45 [1.772]

35 [1.378]
55 [2.165]
Pressure adjustment screw

115 [4.528]

C Drain port

B Outlet port

9 [0.354]
F
G

K
D

180 [7.087]

8 [0.315]

90 [3.543]
113 [4.449]

70 [2.756]
94 [3.701]

A Inlet port

Volume adjustment screw

90 [3.543]

60 [2.362]

C Control
With KL Adjustment

28 [1.102]

65 [2.559]

7 [0.276]

60 [2.362]

170 [6.693]

Pressure
adjustment knob.
Turning clockwise
increases pressure.

MOUNTING FLANGE
AND PORTS CODE

3/8 BSP

1/4 BSP

0.750-16
UNF-2B

0.500-20
UNF-2B

22.5
(0.886)
17.9
(0.705)

20
(0.787)
15.88
(0.625)

3/4 BSP

PS

6
(0.236)
4.76
(0.187)

157
(6.18)
136
(5.35)

44
(1.73)
32
(1.25)

80
(3.150)
80
(3.150)

103
(4.055)
103
(4.055)

1.063-12
UNF-2B

 See model code, page 5.

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

11

VVS1
With ISO or SAE
Mounting Flange
Installation Dimensions
in mm (in)
All mounting flange, port and
shaft options are listed on
page 36.

3rd angle
projection

C Control
With W Adjustment
Pressure
adjustment
screw.
Turning
clockwise
increases
pressure.

30
66 (2.60)
(1.18)
max.

66 (2.60)
JJ
10 (0.39)

CC
Identification plate
Outlet port
D thread

26
(1.02)
70
(2.75)

Case
drain port
J thread

Inlet port
DD thread

131
(5.16)

AA

213
(8.38)

N
120
(4.72)

82
(3.23)

70 (2.76)

BB

34
(1.34)
max.
80 (3.15)

7 x 7 (0.28 x 0.28)
adjuster of maximum
displacement stop
(optional feature see model code)

120 (4.72)

26
(1.02)

182
(3.23)
159 (6.25)

9
(0.35)
GG

C Control
With KL Adjustment

Pressure adjustment
knob. Turning clockwise
increases pressure.

60 (2.36)

191
(7.52)

MOUNTING FLANGE
AND PORTS CODE 

R (ISO)

3/4 BSP 3/8 BSP 8


(0.315)
1.0625-12 0.5625-18 6.35
UNF-2B UNF-2B (0.250)

PS (SAE)

AA

BB

CC

DD

125
(4.921)
127
(5.000)

28
(1.102)
28.17
(1.109)

25
(0.984)
25.4
(1.000)

100
(3.937)
101.6
(4.000)

11
(0.43)
14.3
(0.56)

1 BSP

 See model code, page 5.

12

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

GG

205
(8.07)
1.3125-12 207
UNF-2B (8.15)

JJ

46
(1.81)
48
(1.89)

VVS2 and VVS3


With ISO
Mounting Flange
Installation Dimensions
in mm (in)
All mounting flange, port and
shaft options are listed on
page 36.

3rd angle
projection

C Control
With W Adjustment
K

EE

63 (2.48)

40 (1.57) max.

Pressure adjustment
screw. Turning
clockwise increases
pressure.

JJ

Identification plate

Case drain J thread

10 (0.39)
Outlet port
D

A
H

AA

V
9 (0.35)
10 x 10
(0.39 x 0.39)
adjuster of maximum
displacement stop
Y
(optional feature see model code)

45 (1.77)

BB
R

M
N

P
Inlet port
DD

X
FF
GG

60 (2.36)

C Control
With KL Adjustment

Pressure
adjustment knob.
Turning clockwise
increases
pressure.

MODEL

VVS2

52.4
(2.06)

26.2
(1.03)

30
(1.18)

25
(0.98)

LL

M10 or
0.375-16
UNC-2B 
VVS3
58.7
30.2
35
32
M10 or
(2.31)
(1.19)
(1.378) (1.26)
0.4375-14
UNC-2B 
 See mounting flange/port connections codes RF and PX, page 5.

285
(11.22)

175
(6.89)

110
(4.33)

95
(3.74)

14
(0.55)

10
(0.39)

185
(7.28)

120
(4.72)

105
(4.13)

18
(0.71)

12
(0.47)

M12 or
0.500-13
UNC-2B 
M12 or
0.500-13
UNC-2B 

150
(5.91)

305
(12.01)

1/2 BSP or
0.875-14
UNF-2B 
1/2 BSP or
0.875-14
UNF-2B 

185
(7.28)

MODEL

AA

BB

DD

EE

FF

GG

JJ

LL

VVS2

115
(4.53)
125
(4.92)

114
(4.488)
123
(4.84)

160
(6.30)
200
(7.87)

35
(1.38)
43
(1.69)

35.7
(1.41)
43
(1.69)

40
(1.58)
46
(1.81)

70
(2.76)
77.8
(3.06)

32
(1.26)
40
(1.57)

125
(4.92)
160
(6.30)

38
(1.50)
51
(2.01)

91
(3.58)
105
(4.13)

219
(8.62)
245
(9.65)

279
(10.98)
313
(12.32)

60
(2.36)
68
(2.68)

235
(9.25)
245
(9.65)

VVS3

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

13

VVS2 and VVS3


With SAE
Mounting Flange
Installation Dimensions
in mm (in)
All mounting flange, port and
shaft options are listed on
page 36.

3rd angle
projection

C Control
With W Adjustment

Identification
plate

K
63
(2.48)

40 (1.57)
max.

EE

Key 6,35
(0.25) wide
31,75
(1.25)
210
(8.27)

18
(0.71)

Outlet port D
G

34,5
(1.36)
F
A

T
Z

181
(7.13)

H
E thread

Case drain
0.875-14 UNF-2B

58 (2.28)
10 (0.39)

127
(5.00)
X

45 (1.77)
C

Pressure
adjustment knob.
Turning clockwise
increases
pressure.

GG

60
(2.36)

LL

MODEL

VVS2

52.4
(2.06)
58.7
(2.31)

26.2
(1.03)
30.2
(1.19)

27
(1.06)
35
(1.38)

25
(0.98)
32
(1.26)

0.375-16 UNC-2B 285


(11.22)
0.4375-14 UNC-2B 305
(12.01)

MODEL

DD

EE

FF

GG

LL

VVS2

114
(4.49)
123
(4.84)

35.7
(1.41)
43
(1.69)

40
(1.58)
46
(1.81)

70
(2.76)
77.8
(3.06)

38
(1.50)
51
(2.01)

91
(3.58)
105
(4.13)

219
(8.622)
245
(9.65)

279
(10.984)
303
(11.93)

235
(9.25)
245
(9.65)

VVS3

VVS3

14

Inlet port
DD
FF

10 x 10 (0.39 x 0.39) adjuster


of maximum displacement stop
(optional feature - see model code)

C Control
With KL Adjustment

0.500-13 UNC-2B

9 (0.35)

175
(6.89)
185
(7.28)

110
(4.33)
120
(4.72)

95
(3.74)
105
(4.13)

115
(4.53)
125
(4.92)

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Model Code
VVP Series

Variable Vane Pump

6
R

2
1

Frame Size /
Max. Pressure

16
20
25
32
40
50
63
80
100

Rotation Viewed From


Shaft End

16, 20, 25 cm3/r


Max. pressure 160 bar
(2300 psi)
31.5, 40, 50 cm3/r
Max. pressure 160 bar
(2300 psi)
63, 80, 100 cm3/r
Max. pressure 150 bar
(2200 psi)

Nominal Size /
Geometric Displacement

CR -

Seal Type

Buna N
Viton

CD2 CE -

Pump Design Number

30 All models
Subject to change. Installation
dimensions remain unaltered for
designs 30-39.

16 cm /r (0.98 in /r)
20 cm3/r (1.22 in3/r)
25 cm3/r (1.53 in3/r)
31.5 cm3/r (1.92 in3/r)
40 cm3/r (2.44 in3/r)
50 cm3/r (3.05 in3/r)
63 cm3/r (3.84 in3/r)
80 cm3/r (4.88 in3/r)
100 cm3/r (6.10 in3/r)
3

CVP CVPR CVPD1 -

CVPD2 -

CVPCE -

CVT CVTR CVTD -

Adjust. Max.
Displacement Stop

CVTCE -

S With stop
(Omit if not required.)

RF

11
B C

12

Mounting flange
ISO 3019/2 with straight

Port connections
G (BSPF) thread
keyed shaft
SAE 4-bolt flange with
metric mounting bolts
SAE UNF thread

ISO 3019/2 with straight


keyed shaft
PS
Size 1
SAE B 4-bolt with straight
keyed shaft
PF
Size 2 or 3
SAE C 2-bolt with straight
SAE 4-bolt flange with
keyed shaft (only available UNC mounting bolts
on a primary or single
pump)
PX
Size 2 or 3
ISO 3019/2 with straight
SAE 4-bolt flange with
keyed shaft (available
UNC mounting bolts
only on secondary pump)
B
All
Base plate mounting
O-ring sealed
(available only as
single pump)
Note: See page 36 for detailed dimensional listing for mounting flanges,
shafts and ports.

30-160 bar (430-2300 psi)


(frame sizes 1 and 2)
30-150 bar (430-2200 psi)
(frame size 3)

Adjustment Device

13

Maximum Power Setting


In kW

Applies to CVT pump control only.


** Factory setting of power
limit in kilowatt; for
example 04 = 4 kW

14

Maximum Pressure
Setting

Applies to CVT pump control only.


** Factory setting of
pressure for zero flow in
10 bar increments; for
example 15 = 150 bar

Electrical Rating And


Wiring Connection

For CD*, CVPD*, CVTD pump controls, five options below apply; for
CE, CVPCE, CVTCE, only option 03
applies.
00 No control valve fitted
01 220V AC 50 Hz with DIN
43650 plug connection
02 115V AC 60 Hz with
1/2" NPT conduit box
03 24V DC with DIN 43650
plug connection
04 115V AC 60 Hz with DIN
43650 plug connection
(Omit if not required.)

Control Pressure Setting

Omit for CR, CE, CVPR, CVTD,


CVPCE and CVTCE pump controls.
K Micrometer knob
(standard)
KL Micrometer knob with
key lock

15

Mounting Flange / Port Connections

Size 2 or 3

Standard pressure
compensator
Remote controlled
pressure control
Dual pressure control
with non-adjustable min.
pressure
Dual adjustable pressure
control
Proportional pressure
control
Load sensing
compensator
Remote controlled load
sensing control
Load sensing control with
dual pressure with fixed
minimum pressure
Load sensing control with
dual adjustable pressure
control
Load sensing control with
proportional pressure
control
Torque limiter
Remote controlled torque
limiter
Torque control with dual
adjustable pressure
control
Torque control with
proportional pressure
control

10
10

Code Frame Size


R
Size 1

Pump Controls

CD1 -

7
M
E

Right hand (clockwise)


only

9
C

16

Control Design Number

For all models. Subject to


change. Installation
dimensions remain
unaltered for designs
10-19.

Special Features Suffix

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

15

Technical Data
VVP Series

Nominal size
Displacement according to ISO 3662 - cm3/r (in3/r)

Actual displacement - cm3/r (in3/r)

Mounting flange type (See model code, page 15.)

Maximum working pressure - bar (psi)


Allowed maximum drain port pressure - bar (psi)
Inlet pressure (absolute) - bar (psi)
Speed range - r/min
Rotation direction (viewed from shaft end)
Loads on drive shaft
Maximum torque on primary shaft - Nm (lbf-in)
(See pages 28 and 30 for torque requirements of
combined pumps.)
Hydraulic fluid

Viscosity range at working pressure - mm2/s (cSt)


Recommended viscosity - mm2/s (cSt) at 50C (122F)
Viscosity index
Fluid temperature range - C (F)
Maximum fluid contamination level
Weight - kg (lb)

Size 1
16 (0.976)
20 (1.220)
25 (1.526)
17.9 (1.092)
22.1 (1.349)
26.9 (1.642)
ISO 3019/2
SAE 4-bolt
Base plate
160 (2300)

197 (1744)

Size 2
Size 3
31.5 (1.922)
63
(3.844)
40 (2.441)
80
(4.882)
50 (3.051)
100 (6.102)
34.5 (2.105)
69
(4.211)
42.8 (2.612)
86.2 (5.260)
53.1 (3.240)
105.5 (6.438)
ISO 3019/2
ISO 3019/2
SAE C 2-bolt
SAE C 2-bolt
Base plate
Base plate
160 (2300)
150 (2200)
1 (15)
0.8 to 1.5 [11.6 to 21.8]
800 to 1800
Right-hand (clockwise)
No radial or axial loads allowed
400 (3540)
740 (6550)

Mineral oil - HM according to ISO 6743/4 - HLP according


to DIN 51524/2
Organic ester HFD-U according to ISO 6743/4
(QUINTOLUBRIC N-822-300)
22 to 68
32
100 minimum
-10/+50 [14/122]
Class 9 per NAS 1638, or class 18/15 per ISO 4406
13 (28.7)
33 (72.8)
45 (99.2)

In case of different operating conditions, contact Eaton Hydraulics.

16

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Controls for
VVP Pumps

VVP pumps offer a wide selection of electrohydraulic controls


for the regulation of pressure
and volume.
In addition to the various pressure regulating controls, a
hydraulic load-sensing control is
available to provide pumps with
maximum flexibility for use in
energy saving systems.

Pressure Regulation

The load sensing compensator


control receives a signal pressure directly after an external
throttle and before an actuator.
When a variation in pressure is
sensed (with a fixed fall in pressure p = 20 bar (300 psi), the
control will automatically
change the pumps displacement independent of pressure
variations that occur in the circuit.

The load sensing control produces a notable reduction in


displaced power and is recommended for use in applications
where there are notable variations in torque (or force) and
speed.

Pump With Standard


Pressure Compensator
Model Code C
P

Pump With
Remote Pressure Control
Model Code CR

Remote max. pressure relief valve from 0 to 5 L/min (0 to 1.3 USgpm) not supplied.
Length of pilot line between compensator and relief valve should not exceed 5m (16 ft).

Pump With Two Stages of


Pressure of Which One With
Fixed Setting (At Minimum
Pressure Level of Pump)
Model Code CD1

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

17

Controls for
VVP Pumps
(continued)

Pump With Two Adjustable


Stages of Pressure
Model Code CD2

Pump With
Proportional Pressure Control
Model Code CE

Load Sensing and


Pressure Regulation

Standard load
sense device

Manual or
electroproportional throttle
(not supplied)

Load Sensing Pump for


Standard Flow Control
Model Code CVP
P

Load Sensing Pump With


Remote Pressure Control
Model Code CVPR

Double pressure
load sense
device

Manual or
electroproportional throttle
(not supplied)

Max. pressure relief valve from 0 to 5 L/min (0 to 1.3 USgpm) not supplied.
Length of pilot line between compensator and relief valve should not exceed 5m (16 ft).

18

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Controls for
VVP Pumps
(continued)

Load Sensing Pump With


Two Stages of Pressure of
Which One With Fixed
Setting (At Min. Pressure
Level of Pump)
Model Code CVPD1

Double pressure
load sense
device

Manual or
electroproportional
throttle (not supplied)

Load Sensing Pump With


Two Adjustable Stages of
Pressure
Model Code CVPD2

Double pressure
load sense
device

Manual or
electroproportional
throttle (not supplied)

Load Sensing Pump With


Proportional Pressure Control
Model Code CVPCE

Double pressure
load sense
device

Manual or
electroproportional
throttle (not supplied)

Pressure
Regulation with
Torque Sensing

Torque Limiter
Model Code CVT

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

19

Controls for
VVP Pumps
(continued)

Remote Controlled Torque


Limiter
Model Code CVTR

Remote max. pressure relief valve from 0 to 5 L/min (0 to 1.3 USgpm)


not supplied. Length of pilot line between compensator and relief valve
should not exceed 5m (16 ft).

Torque Control With Dual


Pressure Control
Model Code CVTD
(Fixed Minimum Pressure)

Torque Control With


Proportional Pressure Control
Model Code CVTCE

Double pressure
load sense
device

Manual or
electroproportional
throttle
(not supplied)

20

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Performance
Characteristics
VVP1

Performance with:

Power consumption with


maximum flow

Speed 1450 r/min


Oil per ISO 6743/4

Power consumption with zero


flow setting

Viscosity 32 mm2/s (cSt)


Temperature 50C (122F)

VVP1-16, -20, -25


Values established with zero flow setting

VVP1-16

5 (1.32)

20 (5.28)

8 (10.73)

15 (3.96)

6 (8.05)

10 (2.64)

4 (5.36)

5 (1.32)

2 (2.68)
0

4 (1.06)

16-20-25

3 (0.79)
2 (0.53)
1 (0.26)
0

20 40 60 80 100 120 140 160


(300) (600) (900) (1200)(1500)(1750) (2000)(2300)
Operating pressure - bar (psi)

20
40
60
80
100 120 140 160
(290) (580) (870) (1160) (1450) (1740) (2031) (2321)
pressure bar (psi)

VVP1-16, -20, -25


Maximum noise level measured with sound-level meter placed at
1 meter [39.37] from pump, flexible coupling.

VVP1-20
35 (9.25)

74
12 (16.09)

25 (6.60)

10 (13.41)

20 (5.28)

8 (10.73)
6 (8.05)

15 (3.96)

4 (5.36)
10 (2.64)

2 (2.68)
0

72

16-20-25

70
dB(A)

30 (7.93)

Input power - kW (hp)

Flow - L/min (USgpm)

drainage l/min (USgpm)

25 (6.60)

Input power - kW (hp)

Flow - L/min (USgpm)

30 (7.93)

68
66
64

20
40 60 80 100 120 140 160
(300) (600) (900) (1200)(1500)(1750)(2000)(2300)
Operating pressure - bar (psi)

62
20
40
60
80
100 120 140 160
(290) (580) (870) (1160) (1450) (1740) (2031) (2321)
pressure bar (psi)

VVP1-25

VVP1-16, -20, -25


Response time and pressure peak

40 (10.57)

20 (5.28)

8 (10.73)
6 (8.05)
4 (5.36)

10 (2.64)

2 (2.68)
0

20 40 60 80 100 120 140 160


(300) (600) (900) (1200)(1500)(1750)(2000)(2300)
Operating pressure - bar (psi)

pressure (bar) [psi]

12 (16.09)
10 (13.41)

Input power - kW (hp)

Flow - L/min (USgpm)

280 [4061]
30 (7.93)

16-20-25

220 [3191]
160 [2321]
100 [1450]
40 [580]
0
time ms

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

50 ms

21

Performance
Characteristics
VVP2

Performance with:

Power consumption with


maximum flow

Speed 1450 r/min


Oil per ISO 6743/4

Power consumption with zero


flow setting

Viscosity 32 mm2/s (cSt)


Temperature 50C (122F)

VVP2-32, -40, -50


Values established with zero flow setting

VVP2-32

7.5 (1.98)
18 (24.14)

40 (10.57)

15 (20.12)

30 (7.93)

12 (16.09)
9 (12.07)

20 (5.28)

6 (8.05)
10 (2.64)

3 (4.02)

drainage l/min (USgpm)

50 (13.21)

Input power - kW (hp)

Flow - L/min (USgpm)

60 (15.85)

32-40-50

6 (1.59)
4.5 (1.19)
3 (0.79)
1.5 (0.40)
0

20
40
60
80
100 120 140 160
(290) (580) (870) (1160) (1450) (1740) (2031) (2321)

20 40 60 80 100 120 140 160


(300) (600) (900) (1200)(1500)(1750) (2000)(2300)
Operating pressure - bar (psi)

pressure bar (psi)

VVP2-32, -40, -50


Maximum noise level measured with sound-level meter placed at
1 meter [39.37] from pump, flexible coupling.

VVP2-40

76

21 (28.16)
18 (24.14)

50 (13.21)

15 (20.12)
12 (16.09)

40 (10.57)

9 (12.07)

30 (7.93)

6 (8.05)
20 (5.28)

3 (4.02)
0

70
68

20
40 60 80 100 120 140 160
(300) (600) (900) (1200) (1500)(1750) (2000)(2300)
Operating pressure - bar (psi)

64
0

20
40
60
80
100 120 140 160
(290) (580) (870) (1160) (1450) (1740) (2031) (2321)
pressure bar (psi)

VVP2-32, -40, -50


Response time and pressure peak

60 (15.85)

24 (32.18)
20 (26.82)

45 (11.89)

16 (21.46)
12 (16.09)

30 (7.93)

8 (10.73)
15 (3.96)

4 (5.36)
0

20 40 60 80 100 120 140 160


(300) (600) (900) (1200)(1500)(1750) (2000)(2300)
Operating pressure - bar (psi)

280 (4061)

32-40-50
pressure bar (psi)

75 (19.81)

Input power - kW (hp)

90 (23.76)
Flow - L/min (USgpm)

72

66

VVP2-50

22

32-40-50

74

dB(A)

60 (15.85)

Input power - kW (hp)

Flow - L/min (USgpm)

70 (18.49)

220 (3191)
160 (2321)
100 (1450)
40 (580)
0

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

time ms

50 ms

Performance
Characteristics
VVP3

Performance with:

Power consumption with


maximum flow

Speed 1450 r/min


Oil per ISO 6743/4

Power consumption with zero


flow setting

Viscosity 32 mm2/s (cSt)


Temperature 50C (122F)

VVP3-63, -80, -100


Values established with zero flow setting

VVP3-63

12 (3.17)

100 (26.42)

30 (40.23)
80 (21.13)

25 (33.53)

60 (15.85)

20 (26.82)

40 (10.57)

15 (20.12)
10 (13.41)

20 (5.28)

5 (6.71)
0

120
30
60
90
(400)
(900)
(1300) (1700)
Operating pressure - bar (psi)

8 (2.11)
6 (1.59)
4 (1.06)
2 (0.53)
0

30
(435)

60
90
(870)
(1305)
pressure bar (psi)

120
(1740)

150
(2176)

VVP3-63, -80, -100


Maximum noise level measured with sound-level meter placed at
1 meter [39.37] from pump, flexible coupling.

150 (39.63)

76

42 (56.32)
36 (48.28)

100 (26.42)

30 (40.23)

75 (19.81)

24 (32.18)
18 (24.14)

50 (13.21)

12 (16.09)
25 (6.60)

6 (8.05)
0

30
60
90
120
(400)
(900)
(1300) (1700)
Operating pressure - bar (psi)

63-80-100

74
72
dB(A)

125 (33.03)

Input power - kW (hp)

70
68
66

150
(2200)

64
0

VVP3-100

30
(435)

60
90
(870)
(1305)
pressure bar (psi)

120
(1740)

150
(2176)

VVP3-63, -80, -100


Response time and pressure peak

180 (47.55)

280 (4061)

42 (56.32)
120 (31.70)

35 (46.94)

90 (23.76)

28 (37.55)

60 (15.85)

21 (28.16)
14 (18.77)

30 (7.93)

7 (9.39)
0

30
60
90
120
(400)
(900)
(1300) (1700)
Operating pressure - bar (psi)

150
(2200)

Input power - kW (hp)

49 (65.71)

150 (39.63)

pressure bar (psi)

Flow - L/min (USgpm)

63-80-100

10 (2.64)

150
(2200)

VVP3-80

Flow - L/min (USgpm)

drainage l/min (USgpm)

35 (46.94)
Input power - kW (hp)

Flow - L/min (USgpm)

120 (31.70)

63-80-100

220 (3191)
160 (2321)
100 (1450)
40 (580)
0
time ms

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

50 ms

23

VVP1
With ISO or SAE
Mounting Flange
Installation Dimensions
in mm (in)
All mounting flange, port and
shaft options are listed on
page 36.

3rd angle
projection

C Control
With K Adjustment
KL adjustment is shown on
page 35.

32.5 (1.28)

Pressure setting knob. Turning


clockwise increases pressure.
140 (5.51)

66
(2.60)

Identification
plate

66
(2.60)

19 (0.79)
ISO 4401, size 3
(NFPA D03)
31 (1.22)
control
mounted here

118.5
(4.67)
200.5
(7.89)

P
40.5 (1.59)

JJ
10 (0.39)

70 (2.75)

96
(3.78)

120
(4.72)

82
(3.23)

BB

Case drain J thread


26 (1.02)

26 (1.02)
70
(2.75)

Inlet port. DD thd.


AA
CC
N

Outlet port
D thread

26.6 (1.05)
16.3 (0.64)
6 (0.24)

82 (3.23)
159 (6.25)

120 (4.72)
28
80 (3.15)
9 (0.35)
(1.102)
7 x 7 (0.28 x 0.28) adjuster of maximum
displacement stop; suitable for handwheel.
(Optional feature - see model code)

GG

Thread for remote control connection, type CR = dimension F.


Thread for load sense connection, type CV* = dimension F.

MOUNTING FLANGE
AND PORTS CODE 

R (ISO)

3/4 BSP 1/4 BSP 3/8 BSP 8


(0.315)
1.0625-12 0.500-20 0.5625-18 6.35
UNF-2B UNF-2B UNF-2B (0.250)

PS (SAE)

AA

BB

CC

DD

GG

JJ

125
(4.921)
127
(5.000)

28
(1.102)
28.17
(1.109)

25
(0.984)
25.4
(1.000)

100
(3.937)
101.6
(4.000)

11.0
(0.433)
14.3
(0.56)

1 BSP
1.3125-12
UNF-2B

205
(8.07)
207
(8.15)

46
(1.81)
48
(1.89)

 See model code, page 15.


VVP CONTROL

CR

CD1

20.0
100.0 
(0.79)
(3.94) 
 Includes 13 (0.51) for removal of DIN connector.
Dimension X

24

CD2

CE

CVP

CVPR

CVPD1

CVPD2

CVPCE

CVT(*)

146.0 
(5.75) 

125.5 
(4.94) 

20.0
(0.79)

40.0
(1.57)

120.0 
(4.72) 

166.0 
(6.54) 

145.5 
(5.73) 

115.0
(4.55)

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

VVP2 and VVP3


With ISO
Mounting Flange
Installation Dimensions
in mm (in)
All mounting flange, port and
shaft options are listed on
page 36.

3rd angle
projection

C Control
With K Adjustment
KL adjustment is shown on
page 35.
32.5 (1.28)
26.6 (1.05)
16.3 (0.64)
6 (0.24)

19
(0.79)
ISO 4401, size 3
(NFPA D03)
control
mounted here

X
K

K
140 (5.51) max.

67 (2.64)

P
40.5 (1.59)

31 (1.22)
JJ

Case drain
J thread

EE

10 (0.39)
Identification plate
Outlet port D

NN
MM

M
N
R

E thread
4 places
B

BB AA

9 (0.35)
R

45 (1.77)

P thread
4 places

10 x 10 (0.39 x 0.39)
adjuster of maximum
displacement stop.
Optional feature see model code.

EE

Inlet port
DD

X
Y

FF
GG

Thread for remote control or load sense connection, type CR or


CV* = 1/4 BSP.

MODEL

VVP2

52.4
(2.06)

26.2
(1.03)

30
(1.18)

25
(0.98)

M10 or
0.375-16
UNC-2B 
VVP3
58.7
30.2
35
32
M10 or
(2.31)
(1.19)
(1.378) (1.26)
0.4375-14
UNC-2B 
 See mounting flange/port connections codes RF and PX, page 15.

110
(4.33)

3/4 BSP or
1.0625-12
UNF-2B 
3/4 BSP or
1.0625-12
UNF-2B 

95
(3.74)

14
(0.55)

10
(0.39)

105
(4.13)

18
(0.71)

12
(0.47)

120
(4.72)

M12 or
0.500-13
UNC-2B 
M12 or
0.500-13
UNC-2B 

150
(5.91)

123
(4.84)

185
(7.28)

133
(5.24)

MODEL

AA

BB

DD

EE

FF

GG

JJ

MM

NN

VVP2

114
(4.49)
123
(4.84)

160
(6.30)
200
(7.87)

35
(1.38)
43
(1.69)

35.7
(1.41)
43
(1.69)

40
(1.58)
46
(1.81)

70
(2.76)
77.8
(3.06)

32
(1.26)
40
(1.57)

125
(4.92)
160
(6.30)

38
(1.50)
51
(2.01)

91
(3.58)
105
(4.13)

219
(8.62)
245
(9.65)

279
(10.98)
313
(12.32)

60
(2.36)
68
(2.68)

255.5
(10.06)
275.5
(10.85)

145.5
(5.728)
155.5
(6.12)

VVP3

VVP CONTROL

CR

CD1

20.0
100.0 
(0.79)
(3.94) 
 Includes 13 (0.51) for removal of DIN connector.

Dimension X

CD2

CE

CVP

CVPR

CVPD1

CVPD2

CVPCE

CVT(*)

146.0 
(5.75) 

125.5
(4.94) 

20.0
(0.79)

40.0
(1.57)

120.0 
(4.72) 

166.0 
(6.54) 

145.5 
(5.73) 

115.0
(4.55)

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

25

VVP2 and VVP3


With SAE
Mounting Flange
Installation Dimensions
in mm (in)
All mounting flange, port and
shaft options are listed on
page 36.

3rd angle
projection

C Control
With K Adjustment
KL adjustment is shown on
page 35.

32.5 (1.28)
26.6 (1.05)
16.3 (0.64)
6 (0.24)

19 (0.79)
T
X
K
140
(5.51) max.

40.5 (1.59)

Case drain
1.0625-12 UNF-2B
thread

EE

58 (2.28)

67
(2.64)

18
(0.71)

Identification plate

ISO 4401, size 3


31 (1.22)
(NFPA D03)
control
mounted here

10 (0.39)

Key 6,35 (0.25) wide

Outlet port
D

31.75
(1.25)

NN

34.5
(1.36)
A

210
(8.27)

MM

181
(7.13)

127
(5.00)

E thread
4 places
B
C

0.500-13 UNC-2B
thd. 4 places

45 (1.77)

9 (0.35)

10 x 10 (0.39 x 0.39)
adjuster of maximum
displacement stop.
Optional feature see model code.

EE

Y
FF
GG

Thread for remote control or load sense connection, type CR or


CV* = 0.500-20 UNF-2B

MODEL

VVP2

52.4
(2.06)
58.7
(2.31)

26.2
(1.03)
30.2
(1.19)

27
(1.06)
35
(1.38)

25
(0.98)
32
(1.26)

0.375-16
UNC-2B
0.4375-14
UNC-2B

110
(4.33)
120
(4.72)

95
(3.74)
105
(4.13)

123
(4.84)
133
(5.24)

114
(4.49)
123
(4.84)

MODEL

DD

EE

FF

GG

MM

NN

VVP2

35.7
(1.41)
43
(1.69)

40
(1.58)
46
(1.81)

70
(2.76)
77.8
(3.06)

38
(1.50)
51
(2.00)

91
(3.58)
105
(4.13)

219
(8.62)
245
(9.65)

279
(10.98)
303
(11.93)

256
(10.08)
275.5
(10.85)

145.5
(5.73)
155.5
(6.12)

VVP3

VVP3

VVP CONTROL

CR

CD1

CD2

CE

20.0
100.0  146.0  125.5 
(0.79)
(3.94)  (5.75)  (4.94) 
 Includes 13 (0.51) for removal of DIN connector.
Dimension X

26

CVP

CVPR

CVPD1

CVPD2

CVPCE

CVT(*)

20.0
(0.79)

40.0
(1.57)

120.0 
(4.72) 

166.0 
(6.54) 

145.5 
(5.73) 

115.0
(4.55)

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Inlet port
DD

VVS and VVP


Based Mounted
Installation Dimensions
in mm (in)

3rd angle
projection

Flow adjustment screw (upon request).


Turning clockwise decreases flow.

25 (0.98)
max.

Y max.

C
E (VVP)
N

140 (5.51)
max. (VVP)

Identification plate

AA

G
H
M

2.2 (0.09)

Pressure setting
screw (VVS).
Turning clockwise
increases pressure.

J drain port (VVS1,


VVP1, VVS3 and
VVP3 only)

A
Z

Pressure adjustment knob (VVP)


Turning clockwise increases pressure.

D outlet port

DD inlet port

BB
GG

CC
S

T
U

J drain port (VVS2 and VVP2 only)

MODEL

VVS1
VVP1
VVS2
VVP2
VVS3
VVP3

25
(0.98)
31
(1.22)
53.5
(2.11)

82
(3.23)
110
(4.33)
120
(4.72)

131
(5.16)
175
(6.89)
185
(7.28)

14
(0.55)
24
(0.94)
28
(1.10)

118.5
(4.67)
145.5
(5.73)
155.5
(6.12)

80
(3.15)
113
(4.45)
123
(4.84)

54
(2.13)
75
(2.95)
114
(4.49)

13
(0.51)
20
(0.79)
21
(0.83)

6
(0.24)
10
(0.39)
13
(0.51)

32
(1.26)
50
(1.97)
47
(1.85)

52.5
(2.07)
68
(2.68)
57.5
(2.26)

32.5
(1.28)
45.5
(1.79)
48
(1.89)

5
(0.20)
10
(0.39)
6.35
(0.25)

14
(0.55)
20.5
(0.81)
28
(1.10)

MODEL

AA

BB

CC

DD

GG

VVS1
VVP1
VVS2
VVP2
VVS3
VVP3

25.5
(1.00)
38
(1.50)
57
(2.24)

46
(1.81)
57
(2.24)
76
(2.99)

25.5
(1.00)
30
(1.18)
51
(2.01)

121
(4.76)
159
(6.26)
247.5
(9.74)

140
(5.51)
190
(7.48)
273
(10.75)

21
(0.83)
35
(1.38)
27.5
(1.08)

30
(1.18)
40
(1.57)
40
(1.57)

27
(1.06)
33
(1.30)
55.5
(2.19)

19
(0.75)
32
(1.26)
25.37
(1.00)

89.5
(3.52)
129
(5.08)
140
(5.51)

11
(0.43)
11
(0.43)
13
(0.51)

21
(0.83)
32
(1.26)
35
(1.38)

201
(7.91)
280
(11.02)
300
(11.81)

12.5
(0.49)
-

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

27

Combined
Pumps

The rotor shaft of Vickers()


variable vane pumps is prearranged for mounting an additional pump. Simply take off
the rear cover to easily attach
the secondary pump. (See
items A and B on sectional
view, page 4.)

Vickers() combined standard


pumps (see table below) eliminate the need for many special application pumps.

For solutions other than those


shown in the table, contact
your Eaton representative.

Typical Pump
Combinations

Check valves required


(not supplied) if flows
are combined

Combined pumps

Components for
Combining Pumps

PRIMARY
PUMP

SECONDARY
PUMP

ADAPTER
KIT

PART NO.

VV*1-***-R/PS

VVS0-R
VVS0-PS
VV*1-R
VV*1-PS
SAE A 2-bolt 
VVS0-R
VVS0-PS
VV*1-R
VV*1-PS
VV*2-RF/PX
SAE A 2-bolt 
SAE B 2-bolt 
VV*3-RF/PX

AK-VVS/VVP1-0-R
AK-VVS/VVP1-0-PS
AK-VVS/VVP1-1-R
AK-VVS/VVP1-1-PS
AK-VVS/VVP1-SAE-A
AK-VVS/VVP2/3-0-R 
AK-VVS/VVP2/3-0-PS 
AK-VVS/VVP2/3-1-R 
AK-VVS/VVP2/3-1-PS 
AK-VVS/VVP2/3-2-RF/PX 
AK-VVS/VVP2/3-SAE-A 
AK-VVS/VVP2/3-SAE-B 
AK-VVS/VVP3-3-RF/PX

02-358847
02-358848
02-358849
02-358850
02-358851
02-358852
02-358853
02-358717
02-358854
02-358855
02-358856
02-358857
02-358858

VV*2/3-RF/PF

VV*3-RF/PF

MAX. TORQUE ON
DRIVE SHAFT FOR
SECONDARY PUMP

55 Nm (487 lbf-in)

110 Nm (974 lbf-in)

180 Nm (1593 lbf-in)

 SAE A and B 2-bolt are generic interfaces. Secondary pump with SAE A or B mount should conform to dimensions on
the following page.
 Adapter kits for same displacements within frame sizes 2 and 3 primary pumps are identical.

Ordering Combined
Pumps

Order pumps and coupling unit in progressive order of coupling.


Example:
One (1) VVP1-20-RR-M-30-CVTCE03B-15-10 Primary Pump
One (1) AK-VVS/VVP1-0-R Adapter Kit
One (1) VVS0-10-RR-M-40-CCW-10 Secondary Pump

28

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Combined
Pumps
(continued)

Secondary pumps with SAE


A or B 2-bolt mounts should
conform to the dimensions
below. Dimensions in millimeters (inches).

F
E

2-BOLT FLANGE
PRIMARY OF SECONDARY
PUMP
PUMP 

VVS1
VVP1
VVS2
VVP2
VVS3
VVP3

ADAPTER KIT

E MAX.

SAE A

AK-VVS/VVP1-SAE-A

SAE A

AK-VVS/VVP2/3-SAE-A
AK-VVS/VVP2/3-SAE-B

19.05
(0.75)
19.05
(0.75)
22.2
(0.87)

21.1
(0.83)
21.1
(0.83)
25.1
(0.99) 
25.5
(1.00) 

4.8
(0.19)
4.8
(0.19)
6.375
(0.25) 
4.8
(0.19) 

50
(1.97)
60
(2.36)

SAE B

82.5
(3.25)
82.5
(3.25)
101.6
(4.00)

7
(0.28)
7
(0.28)
9.5
(0.37)

 Secondary pumps with ISO mounting flange are listed on page 28.
 Both shafts are accommodated within same coupling.

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

29

Torque
Requirements
Combined
Pumps

Combined pumps must be


installed in decreasing order of
displacement. Torque requirements and limitations of single
and combined pumps must not
exceed the values shown in the
tables below.

Drive shaft of
primary pump

Pump Frame Size 1


PUMP TYPE

REQUIRED TORQUE
FOR PRIMARY PUMP
Nm (lbf-in)

VVS1-16
VVS1-20
VVS1-25
VVP1-16
VVP1-20
VVP1-25

30 (266)
37 (327)
46 (407)
47 (416)
58 (513)
73 (646)

PUMP TYPE

REQUIRED TORQUE
FOR PRIMARY PUMP
Nm (lbf-in)

VVS2-32
VVS2-40
VVS2-50
VVP2-32
VVP2-40
VVP2-50

57 (504)
73 (646)
91 (805)
92 (814)
117 (1036)
146 (1292)

PUMP TYPE

REQUIRED TORQUE
FOR PRIMARY PUMP
Nm (lbf-in)

VVS3-63
VVS3-80
VVS3-100
VVP3-63
VVP3-80
VVP3-100

92 (814)
117 (1036)
146 (1292)
172 (1522)
219 (1938)
273 (2416)

Pump Frame Size 2

Pump Frame Size 3

30

Drive shaft for


secondary pump

MAXIMUM TORQUE ON
DRIVE SHAFT FOR
SECONDARY PUMP
Nm (lbf-in)

55 (487)

MAXIMUM TORQUE ON
DRIVE SHAFT FOR
SECONDARY PUMP
Nm (lbf-in)

110 (974)

MAXIMUM TORQUE ON
DRIVE SHAFT FOR
SECONDARY PUMP
Nm (lbf-in)

180 (1593)

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August


2004

Dimensions
Combined
Pumps
Installation Dimensions
in mm (in)

VVS1 or VVP1
Primary Pump With
VVS1 or VVP1
Secondary Pump

207 [8.150]

46
[1.811]

159 [6.260]

MOUNTING FLANGE
& PORT CODE

R
PS

46 (1.81)
48 (1.89)

MOUNTING FLANGE
& PORT CODE

R
PS

46 (1.81)
48 (1.89)

207 [8.150]

26
[1.024]

VVS1 or VVP1
Primary Pump With
VVS0 Secondary
Pump

26
46
[1.811] [1.024]

269 [10.591]
205 [8.071]

113 [4.449]

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

31

Dimensions
Combined
Pumps
(continued)
Installation Dimensions
in mm (in)

VVS2 or VVP2
Primary Pump With
VVS2 or VVP2
Secondary Pump

30 (1.18)
91 (3.58)

A
40 (1.57)

115 (4.53) VVS


123 (4.84) VVP
275 (10.83)

115 (4.53) VVS


123 (4.84) VVP
91 (3.58)

MOUNTING FLANGE
& PORT CODE

RF
PF

60 (2.36)
58 (2.28)

MOUNTING FLANGE
& PORT CODE

RF
PF

60 (2.36)
58 (2.28)

275 (10.83)
275 (10.83)
495 (19.49)

VVS2 or VVP2
Primary Pump With
VVS1 or VVP1
Secondary Pump

256 (10.08)

30 (1.18)
91 (3.58)

A
40 (1.57)

32

115 (4.53) VVS


123 (4.84) VVP

260 (10.24)
246 (9.69)
419 (16.50)

56
(2.20)

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Dimensions
Combined
Pumps
(continued)
Installation Dimensions
in mm (in)

VVS2 or VVP2
Primary Pump With
VVS0 Secondary
Pump

60
[2.362]

VVS3 or VVP3
Primary Pump With
VVS3, VVP3, VVS2 or
VVP2 Secondary
Pump

40
[1.575]

RF
PF

60 (2.86)
58 (2.28)

MOUNTING FLANGE
& PORT CODE

RF
PF

68 (2.68)
58 (2.28)

308 [12.126]
258 [10.157]

113 [4.449]

125 (4.92) VVS


133 (5.24) VVP
36 (1.42)

MOUNTING FLANGE
& PORT CODE

A
105 (4.13)

F
46 (1.81)

D
A

SECONDARY
PUMP

VVS3, VVP3
VVS2, VVP2

315
(12.40)
294
(11.57)

105
(4.13)
91
(3.58)

125 (4.92) VVS3


133 (5.24) VVP3
115 (4.53) VVS2
123 (4.84) VVP2

315
(12.40)
300
(11.81)

560
(22.05)
520
(20.47)

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

33

Dimensions
Combined
Pumps
(continued)
Installation Dimensions
in mm (in)

VVS3 or VVP3
Primary Pump With
VVS1 or VVP1
Secondary Pump

275 (10.83)

36 (1.42)
105 (4.13)

125 (4.92) VVS


133 (5.24) VVP

A
46 (1.81)

285 (11.22)
265 (10.43)
444 (17.48)

35
[1.378]

34

338 [13.307]
283 [11.142]

RF
PF

68 (2.68)
58 (2.28)

MOUNTING FLANGE
& PORT CODE

RF
PF

68 (2.68)
58 (2.28)

56
(2.20)

VVS3 or VVP3
Primary Pump With
VVS0 Secondary
Pump

46 [1.811]
68
[2.677]

MOUNTING FLANGE
& PORT CODE

113 [4.449]

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Key Lock
Adjustment for
VVP Pumps
Installation Dimensions
in mm (in)

3rd angle
projection

KL Adjustment For
VVP1, VVP2 and VVP3
Single Pumps

166 (6.54) max.


82 (3.23)

Pressure setting
knob. Turning
clockwise
increases pressure.

KL Adjustment For
VVP1, VVP2 and VVP3
Combined Pumps

A max.
82
(3.23)

Note: Because of length, controls on combined pumps are


mounted perpendicular to pump
shaft.

Pressure setting knob.


Turning clockwise
increases pressure.

ISO 4401, size 3


(NFPA D03)
control
mounted here

PUMP

VVP1

162
(6.38)
155
(6.10)
155
(6.10)

162
(6.38)
189
(7.44)
199
(7.83)

139
(5.47)
166
(6.54)
176
(6.93)

VVP2
VVP3

B
C

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

35

Mounting, Shaft
and Port Options
Installation Dimensions
in mm (in)

Mountings and Shafts


FRAME
SIZE

0
1

MTG.
FLANGE
& PORTS
CODE

R
PS
B
R
PS
B
RF
PF
PX
B
RF
PF
PX

ISO MOUNTING FLANGE

SAE MOUNTING FLANGE

PILOT DIA.

BOLT
CIRCLE DIA.

PILOT DIA.

BOLT
CIRCLE DIA.

FRONT END
DIAMETER

SHAFT
LENGTH

REAR END
DIAMETER

SHAFT
LENGTH

80 (3.15)
80 (3.15)
100 (3.94)
125 (4.92)
125 (4.92)
160 (6.30)
160 (6.30)

103 (4.06)
103 (4.06)
125 (4.92)
160 (6.30)
160 (6.30)
200 (7.87)
200) (7.87)

101.6 (4.000)
127 (5.000)
127 (5.000)
-

127 (5.000)
180 (7.09)
180 (7.09)
-

20 (0.79)
15.88 (0.625)
19 (0.75)
25 (0.98)
25.4 (1.00)
32 (1.26)
32 (1.26)
31.75 (1.25)
32 (1.26)
25.37 (1.00)
40 (1.57)
31.75 (1.25)
40 (1.57)

36 (1.42)
24 (0.938)
32 (1.26)
36 (1.42)
38 (1.50)
50 (1.97)
50 (1.97)
48 (1.88)
50 (1.97)
47 (1.85)
58 (2.28)
48 (1.88)
58 (2.28)

20 (0.79)
20 (0.79)
28 (1.10)
28 (1.10)
28 (1.10)
28 (1.10)
28 (1.10)
28 (1.10)

26 (1.02)
26 (1.02)
45 (1.77)
45 (1.77)
45 (1.77)
45 (1.77)
45 (1.77)
45 (1.77)

Ports

FRAME
SIZE

0
1

MTG.
FLANGE
& PORTS
CODE

R
PS
B
R
PS
B
RF

PF
PX
3

B
RF

PF
PX

36

INLET PORT

OUTLET PORT

G 3/4 BSP
1.0625-12 UNF-2B
21 (0.83)
G 1 BSP
1.3125-12 UNF-2B
32 (1.26)
1.50 SAE 4-bolt
flange with
M12 x 45 deep
mounting holes
1.50 SAE 4-bolt
flange with 0.500
UNC x 1.75 deep
mounting holes
35 (1.38)
2.00 SAE 4-bolt
flange with
M12 x 45 deep
mounting holes
2.00 SAE 4-bolt
flange with 0.500
UNC x 1.75 deep
mounting holes

G 3/8 BSP
0.750-16 UNF-2B
14 (0.55)
G 3/4 BSP
1.0625-12 UNF-2B
24 (0.94)
1.00 SAE 4-bolt
flange with
M10 x 35 deep
mounting holes
1.00 SAE 4-bolt
flange with 0.375-16
UNC x 1.50 deep
mounting holes
28 (1.10)
1.25 SAE 4-bolt
flange with
M10 x 40 deep
mounting holes
1.25 SAE 4-bolt
flange with 0.375-16
UNC x 1.75 deep
mounting holes

DRAIN PORT
VVS PUMPS

DRAIN PORT
VVP PUMPS

REMOTE PRESSURE
CONTROL, LOAD
SENSING AND
DUAL-PRESSURE
LOAD SENSING PORTS

G 1/4 BSP
0.500-20 UNF-2B
6 (0.24)
G 3/8 BSP
0.5625-18 UNF-2B
10 (0.39)
G 1/2 BSP

6 (0.24)
G 3/8 BSP
0.5625-18 UNF-2B
10 (0.39)
G 3/4 BSP

G 1/4 BSP
0.500-20 UNF-2B
G 1/4 BSP

0.875-14 UNF-2B

1.0625-12 UNF-2B

0.500-20 UNF-2B

13 (0.51)
G 1/2 BSP

13 (0.51)
G 3/4 BSP

G 1/4 BSP

0.875-14 UNF-2B

1.0625-12 UNF-2B

0.500-20 UNF-2B

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

Installation
Instructions

components and to have a


low re-cycle speed. To
ensure maximum pump
working life, inlet oil temperature must never be above
50C (122F). In the systems
where the pump runs for a
long time in zero flow setting condition, it is recommended to install a heat
exchanger in the drain line.
The pressure on the drain
port must never be in
excess of the specified
value. The drain pipe must
always be independent of
other return lines, connected
directly to the tank and
extended sufficiently inside
the tank so as to be below
the minimum oil level in
order to avoid generating
foam. Moreover, the drain
pipe must be free of restrictions and as far as possible
away from the inlet pipe.

1) Pump frame sizes 0 and 1


can be mounted in any position. Pump frame sizes 2
and 3 must be mounted
with horizontal axis and the
compensator device upward
( see figure). When the
pump is installed over the
tank oil level, it is recommended to pay attention to
the inlet pressure. The minimum section of the inlet
pipe must be equal to the
section of the thread inlet
port of the pump. The inlet
pipes should be as short as
possible, with a small number of bends and without
inside section changes.
2) All return and drain pipes
must be placed so that the
oil will be not re-sucked
directly from the pump (see
figure). The oil tank must be
suitably sized in order to
exchange the thermal power
generated to the system

3) Motor-pump coupling must

be made with a self-aligning


coupling with convex teeth
and with cam in polyamide
material. When assembling,
maximum attention must be
given to the distance
between the two half-couplings which must imperatively fall within the value
specified in the diagram
below (detail "A"). Other
types of motor - pump couplings are not permitted. No
induced RADIAL or AXIAL
LOADS are allowed on the
pump shaft.

put to the delivery side)


must occur within a few seconds, otherwise the pump
must be turned off and the
operation repeated.
Subsequent start-ups in zero
flow setting conditions are
admissible only with pressure not exceeding 30 bar
(435 psi), and at condition
that the system and pump
be completely filled up with
oil. During the starting operations, both the first and the
followings, the difference
between the oil temperature
and the environment temperature (body pump temperature) must not exceed
by more than 20C (68F).

4) During the first installation,


the pump must be run in
maximum flow condition (P
connected to T), with the oil
flowing directly into the tank,
thus to induce air bleeding.
For sizes 2 and 3 there is an
air bleed placed on the compensator device. This phase
must go on for several minutes. Pump priming (oil out-

4 - 7 [0.157 - 0.276]
DETAIL A

0.05 A

45

50 [2] min

DRAIN

200 [8] min

100 [4] min

OUT

IN
300 [12] min

150 [6] min

EATON Vickers VVS/VVP Variable Displacement Vane Pumps V-PUVN-TM002-E August 2004

37

Eaton
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952 937-9800
Fax: 952 974-7722
www.hydraulics.eaton.com

Eaton
20 Rosamond Road
Footscray
Victoria 3011
Australia
Tel: (61) 3 9319 8222
Fax: (61) 3 9318 5714

Eaton
Dr.-Reckeweg-Str. 1
D-76532 Baden-Baden
Germany
Tel: (49) 7221 682-0
Fax: (49) 7221 682-788

2004 Eaton Corporation


All Rights Reserved
Printed in USA
Document No. V-PUVN-TM002-E
August 2004