Technical Information Sheet KP10

MULTISTAGE OVERVOLTAGE PROTECTION for HIGH DENSITY MDF MODULES


The tertiary stage consists of an impluse clamping circuit which provides protection from the let through impulse of the gas filled arester immediately prior to its firing. This circuitry not only reduces the peak let through voltage below that of conventional multistage protectors but also is more reliable than transzorb diode based secondary circuits.
La
Impulse Clamping Circuit

Ea

Introduction Modern digital switching systems are highly susceptible to transient voltage disturbances. The traditional protection offered by shunt-connected gas filled arresters is no longer a suitable form of protection for these switches. Novaris Technologies MDF module protectors feature multistage protection providing lower let through voltages which provide a safe working environment for sensitive digital equipment. Operation Novaris Technologies multipair protectors are multistage overvoltage protection modules designed for the protection of PSTN equipment and low voltage control circuits, against transient overvoltages caused by lightning, induced impulses and other voltage surges. Each protection module contains ten protection circuits on a single PCB. Each circuit consists of a primary three terminal gas filled arrester, secondary series impedance followed by a tertiary stage transient clamping circuit. The gas arrester provides protection by bypassing transient overvoltages to ground. The arrester is chosen to have a fast impulse response. The secondary stage comprises a series element in each leg consisting of a series impedance which acts in blocking energy let through the gas filled arrester stage.

Lb

Eb

KP10 protection modules are virtually maintenance free as they are designed to fail-safe. The PCB tracks between the line side terminals and gas arrester primary protection act as fuses, causing the line to open circuit in the event of a surge exceeding the capacity of the primary arrester. This failure mode is preferred to an open circuit arrester, which gives no indication of failure. Should such a failure occur, service would be interrupted giving a positive indication of a fault condition. The blown fuses are visible on the exposed circuit board.

Line Fuses

KP10 modules are earthed via two earth tabs, which connect to the KRONE LSA* frame. These heavyduty tabs are substantially built and provide excellent contact with the frame. For later model tubular rod frames, special earth connectors are available as shown in the figure below. The KP10 is suitable for PSTN services. The KP1020 is designed for ISDN, RS232 and UTP network applications. Other voltage ratings are available on request.

Novaris Pty Ltd


72 Browns Road, Kingston, TAS. 7050 AUSTRALIA Copyright 2001 Novaris Technologies E-mail: sales@novaris.com.au ABN: 33 065 427 232 TEL: +61 3 6229 7233 FAX: +61 3 6229 9245

Page 1 of 2

Technical Information Sheet KP10

1) Ch 1:

100 Volt 100 ns

KP10: 150V (100ns/div expanded scale)

1) Ch 1:

100 Volt 100 ns

KP10-20: 60V (100ns/div expanded scale)

Specifications Performance
Configuration: Protection Stages: Surge rating: Let through voltage: 10 pair module Gas arrester / series impedance / impluse clamping tertiary protection. a+b-e 20kA for 8/20us pulse. a-b 10kA for 8/20us pulse. 150V for cat B impulse KP10 60V for cat B impulse KP10-20 -3dB at 20MHz 16 ohm / 1uH 125mm wide x 18mm high x 25mm from front of MDF block. 53g ABS case gold plated PCB pins to * plug into KRONE LSA disconnection block. via MDF frame. -40 - 85C, 10%-95% RH. Sea level to 3050m N2530

AC discharge current: a+b-e 10A at 50Hz for 1s. Frequency response:


1) Ch 1: 2) Ch 2: 100 Volt 5 us 1 kAmps 5 us

Loop impedance: Dimensions: Weight: Construction:

Surge performance for KP10 Applied voltage: 6kV 1.2/50us, 3kA 8/20us (Ch.2 red) Let through voltage: 150V (Ch.1 blue)

Earthing: Temperature Range: Altitude: ACA Approval

The figures below show the improvement in let through voltage that the KP10 offers compared to gas arrester only protection. The gas arrester let through for a category B pulse peaks at 370V compared to 150V for the KP10.

Options
Cat No. KP10
KP10-20

RS232 / UTP

Operating Voltage Application * PSTN KRONE LSA* PSTN


KRONE LSA signal

1) Ch 1:

100 Volt 100 ns

Gas arrester only: 370V (100ns/div expanded scale)

* KRONE-LSA is a trademark of Krone GmbH, Germany

Novaris Pty Ltd


72 Browns Road, Kingston, TAS. 7050 AUSTRALIA Copyright 2001 Novaris Technologies E-mail: sales@novaris.com.au ABN: 33 065 427 232 TEL: +61 3 6229 7233 FAX: +61 3 6229 9245

Page 2 of 2