QUESTIONNAIRE on medium voltage Soft Starters for induction and synchronous motors Company name: City, Country: Responsible person: Phone:
Fax: Parameter
Drive type and destination Motor type Motor rated power, k Motor rated volta!e, " Motor rated #urrent, $ Motor %os Motor e&&i#ien#y &a#tor, ' Motor rated speed, rpm (ype o& ex#itation )brush or brushless* (ype o& ex#iter )thyristor or me#hani#al* Rotor volta!e, " Rotor #urrent, $ Parameters of network (online diagram) "olta!e, " Fre+uen#y, ,.hort #ir#uit power, M"$ (ype o& #ir#uit breakers Rated volta!e o& operative power supply DC or $C*, " Start-up performance /umber o& motors to be start &rom one so&t starter (ype o& start-up pro#edure )loaded or unloaded* (or+ue-speed #urve o& the drive &ly tor+ue )0D1* startin! tor+ue .teady state #urrent a&ter dire#t-on-line start Ratio dire#t-on-line start #urrent to rated #urrent Requirements to Soft Starter .tart-up duration, se# Minimum interval between start-up pro#edures, min /umber o& star-up pro#edures at a stret#h (ype o& start-up #ontrol )lo#al or remote* (ype o& inter&a#e Prote#tion #lass o& e+uipment Climate #onditions
Products order
To get the accurate information on the cost and terms of delivery you should fill in questionnaire corresponding to your order and send it by fax or email. Questionnaire for the thyristor converter (LCI) for soft start of synchronous motors
Questionnaire for the thyristor voltage regulator for soft start of synchronous and induction motors Questionnaire for the thyristor frequency converter Questionnaire for !C
"e send the technical and commercial proposal to the customer #s soon as the consent from the Customer for the order submission is obtained a representative of $ C %#nsaldo&!'I( visits for the Customer)s facility to specify the essential details and plan for the converter equipment arrangement preliminarily. *pon the signing of the Contract+
The detailed ,ro-ect pecification is prepared and agreed upon .ith the Customer/ The input data for detail engineering (see further on for details) are issued for converter engineering on&site The detail engineering pro-ect is agreed upon/ The equipment is manufactured/ #ll the 'quipment types and Converter assembly are tested .ith the testing facilities of $ C %#nsaldo&!'I(/ The Customer)s employees are trained. They ta0e part in testing of the converter)s control cabinet coupled .ith the physical simulator and testing of the equipment .ith the testing facilities/ The 'quipment is sent to the Customer.
1n site+ 'rection supervision of 'quipment is performed/ The participation in testing and ad-usting is conducted/ The commissioning is carried out/ #fter&sales .arranty service is provided.
The input data required for engineering content: The purpose and circuit diagram of the converter
The list of converter equipment and its description 2equirements to s.itchgear Control circuits 2equirements for the relay protection 2equirements for automation (remote control) #lgorithms of the converter operation 2equirements for the auxiliary po.er supply 2equirements for the equipment layout 1utline dra.ings of equipment3 basic and .iring diagrams
http:22www3ansaldovei3#om2en!2442
Address: 453 6rasno0a7armennaya st.3 8osco.3 2ussia3 44459: Tel/Fax: ;< (=>9) ?@4&>4&@?3 ?@4&>:9@3 ?@4&><=<3 ?@4&>?@> E-mail: infoAansaldovei.ru