NOTE : i) All the rates quoted should be inclusive of Service Tax and other local levies as applicale. SURVEYING The job is turnkey in nature for surveying hence includes all cost whatever required for completed 1 work. Job includes carrying out survey at site shown by M/s. BPCL & establishing corners and boundaries at site &installing brick work bench mark duly plastered at all the corners for easy identification. Verification the boundary details given by M/s. BPCL and computation of actual site layout plan are to be done. Making temporary grid marking of the area under scope of survey. At every 5m internal on both the perpendicular direction. Recording the levels with respect to permanent B.M.(to be established by survey team) using dumpy level/theodolite. All existing relevant features like trees, electric lines roads, drains etc. are to be plotted in lay-out plan . One tracing of lay-out plan duly recorded with level and contains to be submitted to M/s. BPCL alongwith 2 copies of Blue Prints of each tracing. Contractor is advised to visit the site before submission of his quote for ascertaining all details/features as relevant for quotation. No extra payment would be entertained for carrying out subject work for the reasons which could be seen/anticipated at the time of quotation. Area of plot under survey is given below : 7007489 7007490 7007491 2 New New New 1 01 02 03 Upto 2000 Sqm.. From 2001Sqm to 10000Sqm For every acre or part there of beyond 10000Sqm SAME AS ABOVE, BUT USING TOTAL STATION Upto 2000 Sqm. From 2001Sqm to 10000Sqm For every acre or part there of beyond 10000Sqm EXCAVATION Excavation in all kinds of soil such as black cotton, silt, earth; murrum; gravel; kankar; boulders; etc. excluding soft and hard rock and carting away the excavated earth to an unobjectionable area upto 100 Mts.from plot boundary or stacking rubble or spreading and leveling within the site as the case may be back filling in layers of 150mm thick including compacting the trenches with excavated earth free from organic matters; stones; sharp edged material; etc; complete. EXC SOIL UPTO1.5 M EXC SOIL 1.5-3M EXC SOIL OVER 3M Excavation in soft rock and carting away the excavated earth to an unobjectionable area upto 100 Mts.from plot boundary or stacking rubble or spreading and leveling within the site as the case may be back filling in layers of 150mm thick including compacting the trenches with excavated 7006799 7006800 7006801 3 01 02 03 earth free from organic matters, stones, sharp edged material , etc, complete. EXC SOFTROCK UPTO 1.5M EXC SOFTROCK 1.5-3M EXC SOFTROCK OVER 3M Excavation in hard rock with chiseling (where blasting is not permitted) and stacking the excavated material as directed. Payment will be made on the basis of stack measurement reducing 30% towards void or as per actual measurement. EXC CHISEL UPTO 1.5M EXC CHISEL 1.5-3M EXC CHISEL OVER3M Excavation in hard rock with blasting after obtaining necessary local approvals; and stacking the excavated material as directed. Payment will be made on the basis of stack measurement reducing 30% towards void or as per actual measurement. EXC BLAST UPTO 1.5M EXC BLAST 1.5-3M EXC BLAST OVER 3M
Page 1 of 111
LS LS LS
01 02 03
M3 M3 M3
M3 M3 M3
01 02 03
M3 M3 M3
01 02 03
M3 M3 M3
SERVICE NO 5
DESCRIPTION OF WORK Excavation in hard rock with compressor/breaker incl. hiring, stacking the excavated materials as directed. Payment will be made on the basis of stack measurement reducing 30% towards void or as per actual measurement. EXC ROCK MECH UPTO 1.5M EXC ROCK MECH 1.5-3M EXC ROCK MECH > 3M Providing timber/ metal sheet shoring/ shuttering for excavation upto 1.5 M Providing timber/ metal sheet shoring/ shuttering for excavation beyond 1.5 M Carting away of excavated earth / debris to an unobjectionable area upto 100 Mts. including loading/unloading and transportation. Carting away of earth / debris etc.lying at site to an unobjectionable area beyond 100 Mts. including loading/unloading and transportation. EARTH FILLING Supplying & filling approved quality murrum in 150 mm thick layer well compacted after sprinkling required quantity of water. The consolidation shall be done using 8-10 ton roller. Measurement shall be taken only after compaction. For non-compacted area 30% would be deducted for voids. Available within the site including cutting if required Brought from outside upto a max of 500 Cum Supplying & filling approved quality murrum in 300 mm thick layer well compacted after sprinkling required quantity of water. The consolidation shall be done using vibrator roller. Measurement shall be taken only after compaction.For non-compacted area 30% would be deducted for voids. Available within the site including cutting if required Brought from outside upto a max of 500 Cum filling with approved quality earth in 150 mm thick layers well compacted after sprinkling required quantity of water upto a max of 500Cum Available within the site Consolidate with 8-10T roller Brought from outside Consolidate with 8-10T roller Available within the site Consolidate with Hand rammer Brought from outside Consolidate with Hand rammer Available within site Consolidate with vibrator roller, in 300 mm layer Brought from outside Consolidate with vibrator roller, in 300 mm layer Filling Stone ,Dust Grit Consolidate with Hand rammer Filling Stone ,Dust Grit Consolidate with 10T roller Filling of river / sweet sand Consolidate with 8-10T roller/hand rammer Bailing out/pumping out water from the pit ; using a 3-5 HP water pump per day Hiring of JCBs per hour Hiring of Cranes per hour upto 5 T cap Removal / disposal of debris from sites to unobjectionable area - Tractors Hiring of Road rollers 8 - 10 ton incl transportation Hiring of vibrator roller - upto 35 tons incl transportation DISMANTLING Scrapping/chipping/breaking old plaster from walls and loose RCC work viz. beams; columns; slabs etc. and disposing the debris to an unobjectionable area as directed. Breaking the following surfaces including disposal of debris as directed Brick Masonary / Laterite Masonry Rubble Masonary Cement Concrete RCC without pneumatic RCC with pneumatic drill Tiles in Flooring/Tiles on wall Steel Structure
Page 2 of 111
UNIT
OLD SOR
01 02 03
01
M3 M3 M3 M2 M2 M3 M3
125
7006842 7006843 2
01 02
M3 M3
90 230
80 250
NEW NEW 3 7006846 7006847 7006848 7006849 NEW NEW 7006850 7006851 7006852 7006853 9002431 NEW NEW
01 02
M3 M3
1540 1540 #N/A 111 234 124 241 1540 1540 390 #N/A 1400 813 1100 1540 1540 1540 1540 #N/A #N/A 65 #N/A 195 234 494 585 700 52 221
110 300
01 02 03 04 05 06 4 5 6 7 8 9 10
NEW 11 NEW 12
85 180 95 185 105 225 300 300 900 625 800 600
80 175 90 180
M2
50
50
M3 M3 M3 M3 M3 M2 M2
SERVICE NO 7006278 7006279 7006280 7006281 New New New New 7006282 08 09 10 11 12 13 14 15 Roofing sheets False ceiling Bitumen Driveway Doors and windows Canopy Gutter Glow box fascia New RVI Fascia Canopy lights
DESCRIPTION OF WORK
UNIT M2 M2 M2 M2 Rm Rm Rm EA M2
01 02
01 02
16 Dismantling sales building / pakka structure including taking out doors / windows, shutters, all type of fittings, fixtures, piping and other equipments. Stacking serviceable material at site as directed and disposing debris away from site irrespective of lead( serviceable dismantled material shall be property of Company and shall be dealt as per directions of site incharge ) measurement of plinth areas are to be taken. Removing the culvert slab from abutment and replacing the slab after cleaning the culvert a. Upto 2.1 m long slab b. Above 2.1 m long slab Dismantling of existing hoarding incl. steel structure ,hoarding board / sheet and stacking aside as directed .Hoarding sheet area will be taken for measurement Dismantling the existing damaged MS /GI Sheet on hoarding board and stacking aside the same as directed . DISMANTLING the following surfaces including disposal of debris as directed. 1) SOLID BLOCKS 2) HOLLOW CEMENT BLOCKS Refixing roofing shets including hooks / screws as required Refixing False ceiling Panels including fixing screws FOUNDATION, PLINTH, SUPERSTRUCTURE Boring holes with augur for single under reamed pile ( single bulb) upto a depth of 3.5M below the ground level including under reamings as per the given design (Note: No payment whatsoever will be made separately on account of chieselling and contractors in their own interest are requested to take into account the variation of the bores etc. while quoting for the item in case of piling)
60 50 50 75 50 60 75 50 350
OLD SOR 60 50 40 75
300
M2 M2 M2 M2
#N/A 234 286 273 65 #N/A 1540 1540 #N/A 1540 1540 #N/A #N/A #N/A
M2 M2 M2 M2
65 65 80 85
01 02 03 04 05
200 mm dia. 230/250mm dia. 300mm dia. 375mm dia. 450mm dia. Boring holes with augur for double under reamed pile ( double bulb) upto a depth of 3.5M below the ground level including under readings as per the given design (Note: No payment whatsoever will be made separately on account of chieselling and contractors in their own interest are requested to take into account the variation of the bores etc. while quoting for the item in case of piling) 200mm dia. 230/250mm dia. 300mm dia. 375mm dia. 450mm dia. Boring holes with augur for piles without bulb upto a depth of 3.5M below the ground level as per the given design (Note: No payment whatsoever will be made separately on account of chieselling and contractors in their own interest are requested to take into account the variation of the bores etc. while quoting for the item in case of piling) 200 mm dia. 230/250mm dia.
Page 3 of 111
M M M M M
01 02 03 04 05
M M M M M
7006919 7006920
01 02
M M
195 247
150 190
150 190
DESCRIPTION OF WORK 300mm dia. 375mm dia. 450mm dia. Boring holes with augur for single under reamed pile ( single bulb) beyond a depth of 3.5M upto 6M below the ground level including under reamings as per the given design (Note: No payment whatsoever will be made separately on account of chieselling and contractors in their own interest are requested to take into account the variation of the bores etc. while quoting for the item in case of piling) 200 mm dia. 230/250mm dia. 300mm dia. 375mm dia. 450mm dia. Boring holes with augur for double undreamed pile ( double bulb) beyond a depth of 3.5M upto 6M below the ground level including under reamings as per the given design (Note: No payment whatsoever will be made separately on account of chieselling and contractors in their own interest are requested to take into account the variation of the bores etc. while quoting for the item in case of piling) 200mm dia. 230/250mm dia. 300mm dia. 375mm dia. 450mm dia. Boring holes with augur for piles without bulb beyond a depth of 3.5M upto 6M below the ground level including under reamings as per the given design (Note: No payment whatsoever will be made separately on account of chieselling and contractors in their own interest are requested to take into account the variation of the bores etc. while quoting for the item in case of piling) 200mm dia. 230/250mm dia. 300mm dia. 375mm dia. 450mm dia. Supplying and laying rubble soling incl. filling the interstices with small pieces of stone/murmur incl.packing; ramming etc. complete Providing and laying Lime concrete 1:2:4 (1 part of lime:2 parts of sand:4 parts of stone aggregate/brick bats) for foundation & plinth under floors Providing and laying plain cement concrete using 40mm metal incl. shuttering form work and curing for a period of 14days. Removing of centering; shuttering; shoring scaffolding shall be done carefully without such shock or vibration as would damage the concrete in foundation and/or plinth 1:3:6 mix. 1:4:8 mix. Providing & laying cement concrete at all height/depth using 20mm metal incl. necessary shutting form work & curing for a period of 14 days Removing of centering ,shuttering, scaffolding shall be done carefully without such shock or vibration as would damage the concrete in foundation and or in plinth. 1:1.5:3 mix. 1:2:4 mix. 1:3:6 mix. Providing and laying reinforced cement concrete using reinforcement and 20mm metal incl. shuttering form work and curing for a period of 14 days. Removing of centering, shuttering, shoring scaffolding shall be done carefully without such shock or vibration as would damage the concrete in foundation; lintel; plinth; column; beam etc. (excluding cost of reinforcement). The job includes usage of vibrator to avoid air gaps during concreting.
Page 4 of 111
UNIT M M M
01 02 03 04 05
M M M M M
01 02 03 04 05
M M M M M
01 02 03 04 05
M M M M M M3 M3
7006943 7006944 10
01 02
M3 M3
2500 2300
2450 2250
01 02
M3 M3 M3
DESCRIPTION OF WORK 1:1.5:3 mix. 1:2:4 mix. BUILDING WORKS Providing and laying RCC with 0.6 to 1% reinforcement for slab using 20mm down metal incl. centering, shuttering and curing for 21 days.(RCC qty upto 2.0 cum only). The cost includes necessary reinforcement steel. 1:1.5:3 mix. 1:2:4 mix. Providing and laying RCC with reinforcement of specified quantity for slab using 20mm down metal incl. Centering, shuttering and curing for 21 days.(Reinforcement will be paid separately). The job includes usage of vibrator to avoid air gaps during concreting. (a) 1:1.5:3 mix. (b) 1:2:4 mix. Providing cold twisted HYSD / TMT steel bars of approved make of reputed concern for RCC work including straightening, cutting, bending, binding and placing in position of 8mm and above dia and M.S. round bars dia. (MAKE : TATA, SAIL,VIZAG STEEL) Providing preconstruction antitermite treatment in column-footing pits, wall trenches, top surface of plinth filling, including to external perimeter of buidling below (External area of the plinth will be paid for all the above total operations) Providing and constructing following incl. curing for 7days the rate includes the cost of scaffolding wherever necessary and racking the joints in foundation and in superstructure RR masonry in cement mortar 1:6 in foundation and plinth RR masonry in cement mortar 1:6 in superstructure. Masonry using laterite in cement mortar 1:6 incl. curing for 7 days. In foundation and plinth. In superstructure. Brick masonry work in foundation using best quality, locally available bricks In CM 1:6 In CM 1:4 Brick masonary work in superstructure using best quality, locally available bricks In CM 1:6 In CM 1:4 Providing and laying brick work in 50 mm thick clay brick tiles with 1:4 cement mortar such as to provide recessed pointing in all shapes and sizes including all material , labour and T & P etc. complete incl.scaffolding,shuttering,curing, etc.complete in superstructure. 115mm thick Brick masonry work in CM 1:4 with MS mesh at every alternative 3 layers with locally available first class bricks and curing for 7 days. Half brick masonry work for partition wall in CM 1:4including RCC stiffeners(3nos 8mm dia on full length )at every 1.2 M height . Providing and constructing masonry with hollow cement blocks of approved quality in CM 1:6 including curing for 7 days. The rate shall be inclusive of scaffolding wherever necessary - in super structure Coarsed rubble stone masonry in CM 1:6 In foundation In super structure Cement plaster in CM 1:4 6mm thick 12mm thick 19mm thick Sand faced cement plaster in CM 1:6 12mm thick 19mm thick Providing and Laying cement plaster to soffits in cement mortar 1:3. 6mm thick 12mm thick
Page 5 of 111
UNIT M3 M3
4400 4000
7007630 7007631 2
01 02
M3 M3
7800 7400
7700 7300
01 02
M3 M3 KG
6600 6000 68
4700 4300 49
4600 4200 48
7006145 4
M2
52
40
40
#N/A M3 M3 M3 M3 M3 M3 M3 M3 M2 2500 2650 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 4000 4100 325 1650 1750 1500 1600 2700 2750 2800 2850 250 2600 1600 1650
2700 240
10 02 7006159 11 03 7006161 12 04
M2 M2 M3
M3 M3 M2 M2 M2 M2 M2 M2 M2
#N/A 2600 2750 #N/A 114 133 165 #N/A 114 146 #N/A #N/A #N/A
SERVICE NO 7006173 17
DESCRIPTION OF WORK Providing and Laying sand faced cement plaster externally in two coats. 1st coat with CM 1:4 mim.15mm thick and 2ndcoat with CM 1:3 min. 6mm thick including smooth or matt finishing the surface etc. complete; including addition of approved waterproofing. Providing and Laying cement plaster externally with CM 1:4 15mm thick and providing 6 MM thick pebble finish plastering second coat using pebble of uniform approved size Extra for providing neat cement punning on plaster/concrete surfaces. Extra for providing neeru finish on plaster for internal wall surfaces. Supplying and fixing chicken mesh before plastering at juctions of walls and RCC members. Carrying out pointing as per standard practice in CM 1:3 On stone masonary. On brickwork. On laterite masonry Providing and laying 40mm thick DPC in CC 1:2:4 (1 Part of cement; 2 Part of sand and 4 part of graded stone aggregate) upto 10mm nominal size laid in proper level line; position as per drawing &a coat of Bitumen of graded 85/25 applied @ 1.7 kg/sq.m after cleaning the surface with brush & finally with a piece of cloth lightly soaked in kerosene oil incl. cost of waterproofing material mixed in CC as per manufacturer's spec. complete in all respect as directed by E.O. Providing and laying reinforced cement concrete using READY MIX CONCRETE WITH 20MM DOWN AGG. incl. shuttering form work and curing for a period of 14 days. Removing of centering, shuttering, shoring scaffolding shall be done carefully without such shock. M 20 GRADE CONCRETE (1:1.5:3 mix). Providing and constructing masonry with 150 THK. SOLID CC BLOCKS of approved quality & including curing for 7 days. The rate shall be inclusive of scaffolding wherever necessary - in foundation and super structure as below. SOLID CC block work in foundation using best quality. In CM 1:6 In CM 1:4 SOLID CC Block work in superstructure using best quality blocks of 150 MM thickness. In CM 1:6 In CM 1:4 Providing and constructing masonry with 200 THK. SOLID CC BLOCKS of approved quality & including curing for 7 days. The rate shall be inclusive of scaffolding wherever necessary - in super structure SOLID CC Block work in foundation using best quality. In CM 1:6 In CM 1:4 SOLID CC Block work in superstructure using best quality. In CM 1:6 In CM 1:4 FLOORING CC Flooring in 1:2:4 mix(20mm and below) including finishing the top in neat cement slurry to make smooth surface and marking the false square or as directed. Providing & laying approved shade & make marble mosaic tiles of 20 to 25 mm thick for flooring or dado on walls icluding bedding of CM 1:4; chipping BM wall as reqd. curing for 7 days & polishing. 01 02 3 Manufactured in grey cement Manufactured in white cement with reqd. colour pigment. Providing and fixing in flooring white first quality glazed tiles 5 mm thick of approved make like BELL,KAJARIA,JOHNSONS,NAVEEN with cement mortar bedding and filling of joint with white cement etc. complete over existing plastered surface. For size 150 x 150mm
Page 6 of 111
UNIT
OLD SOR
M2 M2 M2 M2 M2
250 35 45
M2 M2 M2 M2
55 65 60 170
50 60 50 170
24
#N/A
New 25
01
M3
1540 #N/A
4900
4800
01 02 01 02
M2 M2 M2 M2
01 02 03 04
M2 M2 M2 M2
7006854 1 2
#N/A 1540 1540 #N/A 1540 1540 #N/A #N/A 4600 #N/A
M3
3200
3100
7006857 7006858
M2 M2
375 420
350 400
7006859
01
M2
648
540
540
DESCRIPTION OF WORK For size 100 x 200mm For size 200 x 200mm For size 300 x300mm Providing and fixing white first quality glazed tiles of 5 mm thick in dado of approved make LIKE BELL,KAJARIA,JOHNSONS,NAVEEN with cement mortar and filling of joint with white cement etc. complete. For size 150 x 150mm For size 100 x 200mm For size 200 x 200mm For size 200 x 300mm, 200 x 300 mm Providing and fixing in flooring colored first quality glazed tiles 5 mm thick of approved make LIKE BELL,KAJARIA,JOHNSONS,NAVEEN with cement mortar bedding and filling of joint with white cement etc. complete over plastered surface. For size 150 x 150mm For size 100 x 200mm For size 200 x 200mm For size 300 x300mm For size 200 x 300mm Providing and fixing in dado colored first quality glazed tiles 5 mm thick of approved make LIKE BELL,KAJARIA,JOHNSONS,NAVEEN with cement mortar and filling of joint with white cement etc. complete. For size 150 x 150mm For size 100 x 200mm For size 200 x 200mm For size 300 x 300mm For size 200 x 300mm Providing and fixing in flooring white first quality ceramic tiles 5 mm thick of approved make LIKE BELL,KAJARIA,JOHNSONS,NAVEEN with cement mortar bedding and filling of joint with white cement etc. complete over existing plastered surface. For size 150 x 150mm For size 100 x 200mm For size 200 x 200mm For size 300 x300mm Providing and fixing in dado white first quality ceramic tiles 5 mm thick of approved make LIKE BELL,KAJARIA,JOHNSONS,NAVEEN with cement mortar and filling of joint with white cement etc. complete. For size 150 x 150mm For size 100 x 200mm For size 200 x 200mm, 200 x 300 mm Providing and fixing in flooring coloured first quality ceramic tiles glazed or matt finish of approved make LIKE BELL,KAJARIA,JOHNSONS,NAVEEN & colour with cement mortar bedding and filling of joints with white cement mixed with coloured pigment to match the colour of tiles. etc. complete For size 100 x 200mm For size 150 x 150mm / 200mm x 150mm For size 200 x 200mm / 200mm x 300mm Providing and fixing in dado coloured first quality ceramic tiles glazed or matt finish of approved make LIKE BELL,KAJARIA,JOHNSONS,NAVEEN & colour with cement mortar bedding and filling of joints with white cement mixed with coloured pigment to match the colour of tiles.etc. complete. For size 100 x 200mm For size 150 x 150mm / 200mm x 150mm For size 200 x 200mm Cinder filling works for the toilets to match the level of the toilet floor to the necessary height, compacting etc., complete.
Page 7 of 111
UNIT M2 M2 M2
01 02 03
M2 M2 M2 M2
01 02 03 04 05
M2 M2 M2 M2 M2
01 02 03 04 05 7
M2 M2 M2 M2 M2
01 02 03 04
M2 M2 M2 M2
01 02 03
M2 M2 M2
01 02 03
M2 M2 M2
01 02 03
M2 M2 M2 M3
SERVICE NO 7006886 12
DESCRIPTION OF WORK Providing and Fixing non-skid first quality ceramic tiles7.5mm of SPARTEK/BELL/KAJARIA or of approved equivalent make in approved colour with cement mortar bedding in flooring or skirting including filling of joints with white cement mixed with colored pigment to match the tile colour. Supplying and fixing EURO-CON tiles or equivalent with necessary CM 1:3 bedding including chipping the base as necessary, curing etc. complete. Providing and Laying IPS 50 mm thick in cement concrete1:2:4 mix for flooring and dado including finishing the top in neat cement slurry and marking the false square or as directed. Providing and laying Polished Kota stone flooring /skirting as per required size of thickness 20 to 25mm in1:4 cement mortar including curing polishing etc. complete including rounding off the exposed edges ( nosing ) including cost of all materials, labour etc complete. Supplying and fixing 19mm thick marble stone of approved sills incl. providing bed; mortar in CM 1:4mixture. including rounding off the exposed edges ( nosing ) including cost of all materials, labour etc complete. Supplying and fixing 20mm to25mm thick polished Cuddapah stone for flooring ; pump island including cutting to required shape/size providing bed mortar in CM 1:4 mixture including rounding off the exposed edges ( nosing ), cost of all materials, labour etc Supplying and fixing 19mm thick mirror polished Granite stone of approved quality for flooring/sills/dadoo and pump island including cutting in required shape & size including bedding and backing, including rounding off the exposed edges ( nosing ) including cost of all materials, labour etc complete. as directed. Supplying and fixing 9/10mm thick mirror polished Granite stone of approved quality for sills/dado and pump island including cutting in required shape & size including bedding and backing as directed including rounding of the exposed edges, all cost of materials, labour etc complete. Supplying and fixing 20mm to 25mm thick Red Agra Stone of approved quality for flooring/sills/dadoo including cutting in required shape & size including bedding and backing, including rounding off the exposed edges ( nosing ) including cost of all materials, labour etc complete. as directed. Supplying and laying 20 to 35 mm thk. local sand stone of approved quality with top finished surface for flooring wall cladding including cutting in required shape and 20mm bed in cement mortar. Cutting and shaping the edge of Granite to form Bull nosing for the granites 40mm thick grey terrazo topping rubbed and polished to a granolithic layers 30mm thick cement concrete 1:2:4 and top layer 10mm thick of white marble chips of size above 4mmbut upto 7mm laid in 1:1:%(50 Kg of ordinary grey cement incl. marble powder in the ratio of 3:1) (3 parts of 0.05cu.m. of white marble chippings). Precuts terrazzo tiles of 20mm thick flooring in white cement mixed with light/dark shade pigment with marble chips of size and colour as required mortar 1:3 and jointed with neat cement white slurry mixed with pigment to match the shade of tiles between joints and over the base in floors. treads/riser of steps and landings incl. curing rubbing and polishing. The tiles are to be of approved make/shade. PVC flooring to existing flooring with pesting/cutting/levelling as per requirment and approved shade & make as directed by EO 1.5mm thick 2mm thick Supplying and fixing 20mm to 25mm thick checkered cement tiles in Grey/red or yellow colour in bedding of cement mortar 1:4 mix. Supply & fixing of joint free vetrified floor tiles of 8 MM thick of approved make KAJARIA, BELL, JOHNSONS, NAVEEN or equivalent with cement mortar bedding etc. complete. For size 300 X 300 mm For size 400 X 400 mm For size 600 X 600 mm
UNIT M2
650
M2 M2 M2
7007635 16
M2
1440
1200
1200
7007636 17
M2
540
450
450
7007637 18
M2
3120
2600
2600
7006897 19
M2
#N/A
1300
1300
New 20
M2
1540
725
1540 420
350
7006901 24
M2
420
350
350
#N/A M2 M2 M2 #N/A M2 M2 M2 1540 1540 1540 1000 1000 1200 660 720 #N/A 550 600 400 550 600 400
Page 8 of 111
SERVICE NO NEW 28
DESCRIPTION OF WORK CLAY TILES - P/L GOOD QUALITY LOCALLY AVAILABLE CLAY TILES 200X100 FOR DADOING WITH CM 1:3 INCL COST OF MATERIAL,CONVEYANCE LABOUR ETC COMPLETE - TILE TO BE APPROVED BY ENGG INCHARGE ROOFING Supplying and laying Mangalore tiles in cement mortar in 1:4 on roof or wall etc complete Providing & fixing Corrugated asbestos (Everest/Charminar or approved make) sheet roofing 6 thick sheets fixed with G.I. hooks and bolts bitumen washers complete fixed in position excluding the cost of purlins rafters and trusses. Supplying and fixing AC plain sheet false ceiling incl. supply of screw etc. on the existing frame. 6mm thick Supplying and fixing AC water down take pipe; gutters with fixtures like bends; shore etc. after removing old / broken pipe/gutters incl. fixing necessary MS clamps supports brackets etc. complete for the following : 100mm dia AC water down take pipe 150mm dia AC water down take pipe 225mm dia half round gutter Supplying and fixing PVC pipes( gutters with fixtures like bends; shoe etc. after removing old / broken pipe/gutters incl. fixing necessary MS clamps supports; brackets etc. complete for the following : 50mm dia PVC water down take pipe 75mm dia PVC water down take pipe 100mm dia PVC water down take pipe 150mm dia PVC water down take pipe Asbestos cement valley gutter 450 X 125 X 150mm size; fixed with G.I. 'J' or 'L' hooks 10mm dia and flat iron clamps25mm X 3mm size; G.I. plain and Bitumen washers complete ; excl. the cost of purlins; rafters and trusses. Supplying and fixing corrugated G.I. sheet roofing thick G.I. 'J' or 'L' hooks 10 dia.; G.I. limpet and Bitumen washer complete excl. the cost of purlins; rafters trusses. 20 gauge sheets 24 gauge sheets Supplying and fixing Canopy gutter-trapezoidal section of min. 400mm x 300mm and min.200mm depth made of 0.91 thick Aluminium sheet. The gutter joints shall be fixed by bulb tight rivets and silicon sealant shall be applied all over the joints for leak proof performance Supplying and fixing Canopy gutter end cap made of 0.91mm thick Aluminium sheet Refixing the supplied roofing sheets on canopy as per our standard specifications of fixing roofing sheet. The rate to include cost of labour, scaffolding, necessary materials for fixing etc. complete. Supplying and fixing EVEREST make E board false ceiling incl. fabricating Aluminium frame work; screws etc.complete. Providing & fixing Kailwood/Jambwood batten framing of batten size 50 X 50 complete for fixing asbestos sheet/plywood false ceiling . P/F aluminium "T" 25x50mm & 50x50mm placed at 600mmC/C for placing HD water & Fire proof board & suspended from roof with 8 SWG MS wire P/F Gypsum Board false ceiling, with GI grid, suspended from roof with 8SWG MS wire including putty finish / finishing the joints, 2 coats of plastic emulsion paint etc complete. Supply and fixing of Gypsum board False ceiling with Aluminium Grid T angles, incl. fabricating Aluminium frame work; screws etc.complete. P/F of Synthetic fibre board falsce ceiling of size 600 X 600 mm with necessary aluminium T angles suspended from roof with rigid rods etc. complete. Supply & fixing of aluminium falsce ceiling(tile or track type) perforated ceiling with 600 X 600 MM white in colour with necessary support hangers etc. all inclusive. Providing and fixing marine plywood for partitioning etc. 6 MM THICK
Page 9 of 111
UNIT M2
7007292 1 7007294 2
M2 M2
380 310
375 300
7007295 3 4
M2
324.8 #N/A
290
275
01 02 03
RM RM RM
01 02 03 04
RM RM RM RM RM
#N/A M2 M2 M2 560 532 1568 500 475 1400 500 475 1400
8000542 9 8000543 10
EA M2
515.2 156.8
460 140
460 140
M2 M2 M2 M2
M2 M2 M2
M2
500
500
DESCRIPTION OF WORK 12MM THICK 19MM THICK Providing and fixing commercial plywood for partitioning etc 6 MM THICK 12MM THICK 19MM THICK Supply/fabricating/erecting the Steel Section and in rolled steel sections like R.S.J.; angles; Tees; channels etc and plates; square or rectangular rods.TATA or SAIL make complete.including providing 2 coats of zinc chromate pink primer. (for less than ISA 50,locally available BIS certified sections to be used) Supply/fabricating/erecting the Steel hollow Section in "TATA' or equivalent hollow rectangular/square/round steel pipes .including providing 2 coats of redoxide/zinc chromate pink primer. Only erecting supplied steel structure including painting two coats of Red oxide primer as per specifications. WATER PROOFING Waterproofing with Bitumen felts as per specifications -Scrapping; removing old bitumenised surface. if any cleaning the surface thoroughly with wire brush and duster and providing waterproofing as per specifications Applying one coat of Bitumen primer Applying hot Bitumen 30/40 @ 1.2 Kg/Sq.M. Supplying & Laying Bitumen felt conforming to IS:1322 in lengths at right angles to the direction of the run of gradient starting at the lowest level and overlap of 75mm for adjacent layers; overlap at end of strip of felt to be100mm parapet joints to be suitably fillated and the feltto be taken upto a minimum height 225mm on the parapet. Waterproofing with brick bat / jelly in lime 100mm average thickness and top finished with flat tiles set in cement mortar in 1:4 mixed with water proofing compound and joints cement pointed as per our specifications complete.The cost includes supply & laying of flat tiles. Waterproofing with brickbat coba as per the following specifications. Chipping off top of the deteriorated terrace/slab incl. 150mm of parapet walls upto uniform depth and providing; laying brickbat coba; waterproofing the terrace/slab with an average 100mm. thick concrete of broken brickbats and cement mortar (1:5) in proportions of2 parts of brick bats to one part of cement mortar; laid in proper slope with vata 150mm at junction of parapet wall sand IPS flooring 1:2:4 mix; 30mm thick laid in alternate suitable squares and the joint with bitumen and cleaning the terrace/slab top of all dust; loose materials; tamping finishing and curing complete. Waterproofing the roof slab with ROFF waterproofing compound or any other equivalent water proofing compound as approved by the engg incharge, mixed with cement slurry with 2 coats of 1mmthickness recommended by manufacturer. Providing & fixing of Roof tiles with proper slope with lime mortor (2:2:7) jointing with cement slurry & finished with machine cutting . Rounded off at the joints of roof ¶pet walls with cem. conc.(1:2:4) as directed by EO DOORS AND WINDOWS AND SHUTTERS Supplying /fixing fully moulded FRP door 1.25 inches thick including fixing with 3 nos Brass hinges of size 4 inch, lock ,CP brass handles etc. complete for toilet / wash rooms etc. Supplying; fitting fixing in position plain/frosted float glass of Modi float or equivalent for glazed show window duly fixing with metal/aluminium clamps/putty etc. complete as directed including transparent sealant as required. 3 mm thick glass panel 5.5 mm thick glass panel 10 mm thick glass panel 12 mm thick glass panel 12 mm thick toughned curved glass incl all fixing arrangements 6 12 mm thick toughned straight glass incl all fixing arrangements
UNIT M2 M2 M2 M2 M2 KG
7007318 21
KG
81
65
64
7007319 22
KG
15 #N/A 237.6
11
10
7007617 1
M2
220
220
7007618 2
M2
297
275
250
7007619 3
M2
405
375
350
7007623 4
M2
300
240
230
7007624 5
M2
375
310
300
7006290 1 2
M2
1850
1800
01 02 03 04 05
M2 M2 M2 M2 M2 M2
Page 10 of 111
SERVICE NO 3
DESCRIPTION OF WORK Providing and fixing frame work for fixed glass show window out of aluminium section size 101 x 45mm x 2.10 mm with PVC beading & glazing clip of 0.071 kg/M.( Jindal section or equivalent by weight) With 15 micron anodized aluminium With 50 to 60 micron powder coated aluminium Providing and fixing frame work for fixed glass show window out of aluminium section size 45mm x 45mmx 1.8mm(4577)with PVC beading & glazing clip of 0.071 kg/M.(Jindal sections or equivalent by weight) With 15 micron anodized aluminium With 50 to 60 micron powder coated aluminium Fabricating openable type window section of Jindal Casement window series 'B' or equivalent by weight .(a) Main frame Secno 8462(42mmx31mm,1.6mm thick) (b) shutter frame Sec No 8463 (42mmx31.2mm,1.6mm thk)( c ) 5mm thick clear float1 glass (d) clip Sec No 8461(28mmx15.3mm,1.6mmthk) (e) Mulion Sec No 8464(46.2MMX42MM,1.6MMTHK) with handles, hinges and stoppers of anodized aluminium sections.( Jindal sections or equivalent by weight) With 15 micron anodized aluminium With 50 to 60 micron powder coated aluminium Providing and fixing sliding window with pipe frame & two tracksection or as directed with 5.0mm thick clear float glass. (a) Twotrac bottom Sec No 8687(61.85 x 31.75 x 1.2mm thick) (b) Two tractop Sec No 8758 (61.85 x 31.75 x 1.3mm thick) ( c) Shutter : 8665 on side( Top/Bottom Sec No 8663(40 x 18 x 1.25mm thk) (d)Inter lock Sec No 8664(40 x 18 x 1.1mm Thick) .Jindal sections or equivalent by weight) With 15 micron anodized aluminium With 50 to 60 micron powder coated aluminium Providing & fixing in position three track aluminium sliding windows with 5mm thick clear float glass panel of approved shade & make- Modi / Saint Gobian with aluminium sections for outer frame sections -bottom no.8688, top & sides no.8689, shutter top & bottom no.8663, side handle no. 8665, Inter lock no.8664. The shutters should be mounted on Nylon rollers & approved quality fixtures such as aluminium handles, tower bolts, rubber beadings including cost of all necessary materials, labour, powder coating to approved colour,cutting to the required length, joints mitered sub dividing the frame tennoned and riveted in the assembled frame to be stiffened with end clips , corner angles etc fixed to wall, lintel, floor beams with necessary steel screws, rawl plugs & teak wood wedges including making the surface good with cement mortar, One Extra shutter to be provide with stainless steel mesh of approved size, with all lead & lift charges etc., complete for windows as per design & drawing. (jindal sections or approved equivalent ) With 15 micron anodized aluminium With 50 to 60 micron powder coated aluminium Providing and fixing louvered window of 100mm wide 5mm thick glass adjustable type for ventilation as per required size including keeping opening for fixing exhaust fan if required. (Frame Sec No4605) ( Jindal sections or equivalent by weight) With 15 micron anodized aluminium With 50 to 60 micron powder coated aluminium Providing and fixing 15 micron anodized aluminium door on floor spring without vertical members but with special section of size appro 90mm X 40 mm ( 3.48 kg/M) for top &bottom fully glazed with float glass unit and comprising of with locking arrangements, handles on both the sides including tower bolts 10mm thick plain glass panes. 12mm thick plain glass panes. Providing and fixing 50-60 micron powder coated aluminium door on floor spring without vertical members but with special section of size approx. 90mm X 40 mm ( 3.48 kg/M)for top & bottom fully glazed with float glass unit and comprising of with locking 10mm thick plain glass panes. 12mm thick plain glass panes.
Page 11 of 111
UNIT
OLD SOR
7006295 7006296 4
01 02
M2 M2
1300 1500
1250 1400
7006297 7006298 5
01 02
M2 M2
1150 1225
1100 1200
7006299 7006300 6
01 02
M2 M2
2350 2600
2300 2500
7006301 7006302 7
01 02
M2 M2
2300 2500
2300 2500
NEW NEW 8
2600 2800
2500 2700
7006303 7006304 9
01 02
M2 M2
2150 2300
2150 2300
7006305 7006306 10
M2 M2
2800 3000
2600 2800
7006307 7006308
01 02
M2 M2
#N/A #N/A
3000 3200
2800 3000
SERVICE NO 11
DESCRIPTION OF WORK Fabricating erecting in position door frame using fully glazed shutter of the following sections. (a) Door outer frame Sec No 4605. (b) shutter bottom Sec No 4530 1.8mm thick(c)Shutter top Sec No 4531 (d) shutter vertical Sec No 4504 2.5mm thick(e) lock rail Sec No 4621 (f) 5 mm thick clear float glass(g) with anodized aluminum hinges; handles on both sides concealed vertical locks; openable from both the sides and tower bolts. (if required) ( Jindal sections or equivalent by weight) 01 02 12 With 15 micron anodized aluminium fully glazed shutter With 50 to 60 micron powder coated aluminium fully glazed shutter Fabricating erecting in position door frame using fully panelled shutter of the following sections. (a) Door outer frame Sec No 4605. (b) shutter bottom Sec No 4530 (c)Shutter top Sec No 4531 (d) shutter vertical Sec No 4504(e) lock rail Sec No 4621 (f) panels 10 gauge aluminum sheet (g) with anodized aluminium hinges; handles on both sides; concealed vertical locks; openable from both the sides and tower bolts. (if required) ( Jindal sections or equivalent by weight) With 15 micron anodized aluminium panelled shutter With 50 to 60 micron powder coated aluminium panelled shutter Fabricating erecting in position door frame using fully panelled shutter of 12 mm thick Novapan board of the following sections. (a) Door outer frame Sec No 4605.(b) shutter bottom Sec No 4530 (c) Shutter top Sec No 4531 (d)shutter vertical Sec No 4504 (e) lock rail Sec No 4621 (f) panels12mmthick Novapan or equivalent particle board laminated on both sides (g) with anodized aluminium hinges; handles on both sides concealed vertical locks; openable from both the sides and tower bolts. (if required) ( Jindal sections or equivalent by weight) With 15 micron anodized aluminium panelled shutter With 50 to 60 micron powder coated aluminium panelled shutter Fabricating erecting in position door frame using fully panel with aprrox 3mm thick PVC panel of approved make &shade of the following sections. (a) Door outer frame SecNo 4605. (b) shutter bottom Sec No 4530 (c) Shutter top SecNo 4531 (d) shutter vertical Sec No 4504 (e) lock rail SecNo 4621 (f) with anodized aluminium hinges; handles on bothsides; concealed vertical locks; openable from both the sides and tower bolts. (if required) ( Jindal sections or equivalent by weight) With 15 micron anodized aluminium fully panel With 50 to 60 micron powder coated aluminium fully panel Fabricating erecting in position door frame using sections partly Novapan panelled and partly glazed shutter of aluminium of the following sections. (a) Door outer frameSec No 4605. (b) shutter bottom Sec No 4530 (c) Shutter top Sec No 4531 (d) shutter vertical Sec No 4504 (e) lock rail Sec No 4621 (f) 5 mm thick clear float glass (g) 10 gauge aluminium panel; with anodized aluminium hinges; handles on both sides; concealed vertical locks; openable from both the sides and tower bolts. (if required) ( Jindal sections or equivalent by weight) With 15 micron anodized aluminium sections With 50 to 60 micron powder coated aluminium section Providing and fixing 125 x 75mm teak wood frame and 40mm thick flush door shutters with core of block board of first class hard wood with internal beading and well matched with 3mm veneered marine ply on both faces of shutters including 3 Nos brass butt hinges chromium plated handles, tower bolts etc. complete. Providing and fixing 125 x 75mm teak wood frame and 40mm thick flush door shutters with core of block board of first class hard wood with internal beading and well matched with decorative 3mm veneered plywood on both faces of shutters including 3 Nos brass butt hinges chromium plated handles, tower bolts etc. complete. Providing and fixing 32mm flush door shutters in existing frames 3mm veneered non decorative type commercial quality including (3 Nos) brass hinges chromium plated handles, tower bolts etc. complete.
UNIT
OLD SOR
7006309 7006310
M2 M2
3000 3100
3000 3100
7006311 7006312 13
01 02
M2 M2
3400 3600
3400 3600
7006313 7006314 14
01 02
M2 M2
3100 3300
3100 3300
7006315 7006316 15
01 02
M2 M2
2500 2600
2500 2600
M2 M2 M2
7006322 17
M2
3720
3100
3000
7006323 18 01
Page 12 of 111
SERVICE NO 7006324 19
DESCRIPTION OF WORK
UNIT
7006325 20 7006326 21
7006327 22 7006328 23 24
01 02 03 04 05 06
7006347 34
Providing and fixing 40mm flush door shutters in existing frames decorative type veneered plywood M2 3mm thick marine quality including (3 Nos) brass hinges chromium plated handles, tower bolts etc. complete. M2 Providing and fixing decorative laminate of 1.5 mm thickness minimum and of reputed approved make and shade (Formica/Rammica/Neolune) Providing and fixing 125 x 75mm teak wood frame and 40mm panelled door shutters with 12mm waterproof/marine ply panel including 3 Nos brass butt hinges and chromium plated tower bolts, handles etc. complete. M2 EA Providing and Fixing 16mm dia x 300mm long brass chromium plated Aldrop for the doors with necessary fixture etc. complete. EA Providing and Fixing Tower Bolt of 200 mm brass chromium plated or powder coated. Providing and fixing steel doors with frame of standard rolled steel sections, joints mitred and welded with 16mm x 3.5mm lugs 100mm long embedded in cement concrete or with wooden plugs and screws as required including providing and fixing 18 guage MS plate Single leaf steel doors M2 Double leaf steel doors M2 M2 Repairs of steel panel doors with MS sheet 20 gauge incl.removing transporting to workshop welding and refixing at the original position. Removing beadings and fixing in position - plain/frosted sheet glass; including cutting to sizes for old glazed doors and windows duly fixing with metal/aluminium clamps/putty or wooden battens for beading with suitable handles etc.complete as directed : 3mm (1/8 In.) thick glass pane M2 4mm thk glass pane M2 5.5 mm thk glass pane (Modi float/Safex) M2 8 mm thk glass pane (Modi float/Safex) M2 10 mm thk glass pane (Modi float/Safex) M2 12 mm thk glass pane (Modi float/Safex) M2 Removing the beading and fixing in position - old plain/frosted sheet glass; including cutting to sizes; for old glazed ventilator sand louvers duly fixing with metal/aluminium clamps/putty or wooden battens for beading with suitable handles etc. complete as directed : 3mm (1/8 In.) thick glass pane M2 4mm thk glass pane M2 5.5mm (1/4 In.) thick glass pane M2 EA Providing and fixing Floor spring of Everite or equivalent make SET Providing and fixing 40mm dia of B class Brass / Glass handle on both sides of the door including necessary brackets.. EA Providing and fixing 6 lever mortice lock of godrej or approved make. EA Providing and fixing hydraulic door closer Everite or equivalent. Providing and fixing chrome plated brass 100mm Mortice latch and lock with 6 levers and a pair of EA lever handles with screws as necessary complete. M2 Fixing supplied steel/wooden windows /doors /ventilators/louvers etc. in walls as directed incl. supply of screws/hooks/bolts/nuts etc. but excl. cost of doors/windows/louvers/ventilators as the case may be. M2 Supplying; fitting in position steel door of approved make fabricated out of 'Z' section conforming to IS 1038; 4351;1001 of thickness 3mm. joints mortice and welded with20mmX5mm MS flat hinges; half panelled using 3mm thick glazed glass panel with glazing chips and specification putty of Shalimar make and colour;superior quality heavyduty Chromium plated brass stays;aldrops; handles; lowerbolts and half portion covered with one shop coat with frame complete. Supplying; fitting and fixing in position steel window and ventilator of standard sections frame toughened glass panes frame provided with steel hold fasts embedded in cement concrete block 1:2:4 grade; suitable handles; painted with one shop coat etc. complete. 3 mm thick toughened glass panes frame 5 mm thick toughened glass panes frame
1650
390 #N/A
325
300
2220
1850
1800
35
#N/A
7006348 7006349
01 02
M2 M2
1800 1920
1500 1600
1500 1600
Page 13 of 111
DESCRIPTION OF WORK Providing and fixing Toilet block door with powder coated aluminium frame and PVC (syntex) shutter with necessary fitting and fixture of approved make. Providing and fixing Toilet block door with Syntex frame and PVC moulded (syntex) shutter with necessary fitting and fixture of approved make or equivalent. Providing and Fixing Pull & Push type Steel Rolling Shutters of 18 gauge MS plate of deep - convex corrugations complete with one piece construction, side guide 2 1/2 In. x 1 In. of 18 gauge plate, brackets, suspension shafts, top rolling spring, locking device, hood cover etc. include 2 coats of primer and 2 coats of enamel paint of approved colour. Providing and Fixing Pull & Push type Steel Rolling Shutters of 18 gauge MS plate of deep - convex corrugations complete with 600mm grill in full width of rolling shutter, side guide 2 1/2 In. x 1 In. of 18 gauge plate, brackets, suspension shafts, top rolling spring, locking device, hood cover etc. i/c 2 coats of primer and 2 coats of enamel pant of approved colour. Providing and Fixing Pull & Push type Steel Rolling Shutters of full grill with side guide 2 1/2 In. x 1 In. of 18 gauge plate, brackets, suspension shafts, top rolling spring, locking device, hood cover etc. include 2 coats of primer and 2 coats of enamel pant of approved colour. Supplying and fixing MS decorative Grill for window , ventilator , compound wall made out of ( vertical channel 20x10x2mm & sq.bars or flats or Square or rectangular M.S. hollow sections (upto 20kg. per sq.m.) as per approved design including 2 coats of primer and 2 coats of Synthetic enamel paint. Providing and fixing in position collapsible steel shutter with vertical channel 20x10x2 mm and braced with flat Iron diagonals 20x5 mm size with top and bottom rail of T iron 40x40x6 mm with 40 mm duia pully complete with bolts nuts locking arrangement stopper handle including appplying one coat primer.and 2 coats of paint. Suppling & Fixing of Sal wood frame 100mmx 50mm with required Holdfast fixing with cement concrete (1:2:4) & finishing the position with cement mortar; proper plumbing & levelling Supplying & Fixing of wooden Door/Window panel shutter of 37mm thick fixing with steel hinges; tower bolts door handle with locking arrangement stopper etc. complete as directed by EO. Providing and fixing windows of all sizes and shape including sal wood frame of section 100 mm x 65 mm including 35 mm thick second class teak wood fully glazed double leaf shutters having styles, top and bottom rail of section size 75 mm x 35 mm and also intermediate sectional size 50 mm x 35 mm inter locked with each other by wood joinery, also including 4 mm thick plain float glass fitted with teak wood 12 mm beading of suitable size of a approved design and shape on both sides of glass incl. fixing shutters with chaukhat with 4 Nos of M.S. hinges with brass fittings ( 2 Nos Handles , 2 Nos tower bolts , 2 Nos stays brass serews etc. ) The window chaukhat is to be fixed with 4 Nos of M.S. hold fast embedded in 1:2:4 c.c. blocks incl. surface preparation & smooth polishing with French polish etc. complete ( glazing area upto 60% of window area) Providing and fixing doors including door chaukhat of sal wood of sectional size 100 mm x 65 mm in all shapes fixed with 6 Nos of MS hold fast embedded in 1:2:4 c.c. blocks and 35 mm thick teak wood leaf shutter fully glazed having styles and top rail of and intermediate horizontal and vertical rails of size 50 x 35 mm , interlocked with wood joinery and fixed to chawkhat with M.S. hinges , brass screws , also fitted with approved quality of 2 Nos brass handle, 2 Nos brass tower bolt, 1 No brass L-prop , 1 No brass stopper , also including .4 mm thick plain float glass fixed with 20 mm x 25 mm teak wood beading of approved size and shape on both faces of shutter including all material , labour and T & P required incl. surface preparation & smooth polishing with French polish etc. complete in all respect ( glazing upto 40 % of door area) Providing and fixing vertical blinds of Trac or equivalent make including frames and all accessories complete Providing and fixing venetian horizontal blinds including frames and all accessories complete Supplying and fixing Sun film on glasses of Garware or equivalent make.
Page 14 of 111
UNIT M2 M2 M2
7006353 39
M2
2820
2350
2300
7006354 40
M2
2940
2450
2400
7006355 41
M2
1440
1200
1200
7006356 42
M2
2280
1900
1800
7006357 43
M3
42000
35000
35000
7006358 44
M2
3120
2600
2600
7006359 45
M2
3240
2700
2600
7006360 46
M2
3600
3000
2800
SERVICE NO 7007320 1
DESCRIPTION OF WORK SANITARY Providing and fixing vitreous china water closet Wall hung type (European type) of approved colour having back inlet P trap with seat and lid with C.P. brass hinges and rubble buffers; supporting cast iron chair with bolts. (if required) (Hindware/Parryware/Neycer) Providing and fixing vitreous china water closet Wall Pedestal Type (European type) of approved colour having back inlet "P" trap with seat and lid with C.P. brass hinges and rubble buffers; supporting cast iron chair with bolts. (if required) Providing & fixing glazed Orissa Pattern W.C. pan (IndianType) of approved colour & shade and of size 580 x 440mmconforming to IS 2556 (Part III) together with glazed S/P trap as per IS 2556 (Part III); both of approved make & in selected colour. Breaking the flooring and removing Indian/Western style W.C. Providing & fixing PVC low level flushing cistern of ISI mark; 10 lit capacity; with CI brackets; 32 mm concealed PVC flush pipe brass ball cock with PVC ball; 15 mm CP brass stop cock; 15mm PVC inlet connection; 15 mm PVC overflow pipe including connection to water closet etc. complete. Replacing flush tank with PVC flush tank ISI approved incl. All connections Replacing WC basin only complete with fittings. (22 In. In.size, white ) Cera / Somani or approved make. In. Indian type Western type Supplying/fixing Health Faucets in toilets including necessary fixtures etc., complete. P & F push button type C.P. flush valve with 32 mm dia partly concealed PVC flush pipe complete including connection to water closet. Providing and fixing approved make white glazed flat back or wall corner urinal wall mounted type including all necessary fixtures like inlet pipe and 12.5mm CP cock outlet CP bottle trap brass water sprayer set., complete. Supplying/fixing senser urinals, Hindware - 6007 or equivalent for the toilet, including all necessary fixtures Providing and fixing 630 x 510mm size white vitreous china wash basin of CERA or other approved make & shade suitable for mounting on GI rag bolts with half pedestal (pedestal fixed with screws). 32mm dia CP brass waste coupling of standard pattern, 32mm dia. CP brass bottle trap and unions, 32mm dia PVC waste pipe, C.P. brass chain with plug and 15mm CP brass pillar tap, CP brass stop tap with PVC connection, complete. Providing and fixing 450 x 300mm size white vitreous china wash basin of CERA or other approved make & shade suitable for mounting on GI rag bolts with half pedestal (pedestal fixed with screws). 32mm dia CP brass waste coupling of standard pattern, 32mm dia. CP brass bottle trap and unions, 32mm dia PVC waste pipe, C.P. brass chain with plug and 15mm CP brass pillar tap, CP brass stop tap with PVC connection, complete. Providing and fixing 550 x 400 mm size white vitreous china wash basin of CERA or other approved make & shade suitable for mounting on GI rag bolts with half pedestal (pedestal fixed with screws). 32mm dia CP brass waste coupling of standard pattern, 32mm dia. CP brass bottle trap and unions, 32mm dia PVC waste pipe, C.P. brass chain with plug and 15mm CP brass pillar tap, CP brass stop tap with PVC connection, complete. Supplying/fixing Bottle trap with waste coupling for the wash basin inculding necessary fixtures. Providing and fixing 600 x 450mm bevelled edge mirror of superior glass of approved quality with 6mm thick asbestos cement sheet ground fixed to wooden cleats with CP brass screws and washers complete as required. Providing/fixing Mirrors with min 6 mm thick, with fittings Modi / saint gobain or equivalent as approved by Engg incharge. Providing and fixing SS /CP Brass soap dispenser of superior quality. Supplying/fixing soap dish in toilet including necessary fixtures etc., complete. P&F in position Indian make CP brass paper holders fixed into wall with CP brass screws complete in all respects. cutting and making good the walls etc.
UNIT EA
7007321 2
EA
2375
1900
1900
7007322 3
EA
2250
1800
1800
7007324 4 7007325 5
EA EA
250 1125
200 900
200 900
EA
1000
1000
EA EA EA EA EA
1400 1500
1500 1000
11 7007332 12
EA EA
#N/A 1875
7007333 13
EA
1500
1200
1200
14
EA
#N/A
1400
1400
7007334 15 7007337 16
17 7007338 18 19 7007339 20
#N/A M2 EA EA EA 250 #N/A 281.25 400 200 150 225 400 200 150 225
Page 15 of 111
SERVICE NO 21 7007341 22 23 24
DESCRIPTION OF WORK Supplying/fixing Pillar cocks Jaquar make or equivalent including necessary fixtures etc., complete. Providing and fixing Orient make CP brass wall shower with15/20mm inlet connections and 63mm dia. Swivel type shower with arm etc. complete as required. Supplying/fixing stop valve concealed in toilets for water lines Providing & laying,jointing,fixing & testing heavy duty 6 kg/cm2 UPVC pipe ISI marked pipe lines incl. fitting like tees,bends,sockets,elbows etc. in trenches in the ground/in wall ,cutting, & testing etc. complete 12 mm 19 mm 25 mm 40 mm 50 mm 75 MM 100 mm 150 mm 200 mm Supplying /fixing Stainless Steel ( SS ) Hand railings for Staircase portion with 2" dia hand rail, 4 lines of 3/4" horizontals and 1 1/2" dia veritcals at every 1m fixing etc., complete. Supplying and fixing earthware gully trap 100mm size with CI grating on top incl. constructing suitable masonry chamber and plastering etc. complete. Providing and fixing sand cast iron Nahani trap of self cleansing design with sand cast iron or C.P. brass grating with or without vent arm; of the below mentioned sizes for inlet and outlet; complete including cost of cutting and making good the walls and floors wherever if required. 75mm 100mm Supplying and fixing Non Return Valve for water tank.Leader make 19mm 25mm Supplying/fixing Wall mixer Jaguar or equivalent make, with one hot water and one cold water tap, selection lever, along with shower outlet, including necessary wall fixtures etc., complete. Providing and fixing round grating 150 mm dia to rain water pipe CI Grating CP Brass Grating Making connection to main sewer line with existing manhole including breaking and making good the wall and floor with cement conc. 1:3:6 mix cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. Constructing conical manhole in 230mm thk BM 1:6 cement CM 1200mm clear inside dia at bottom and 600mm clear inside dia at top and clear height as mentioned below with 1:3:6 cc bedding 100mm thk in foundation,1:2:4 cc coping 100mm thk at top, BM hunches,150mm dia half round channel in the hunches, incl.excavation,backfilling and carting away excavated earth,plastering from inside in 1:4 CM with punning upto 1200mm clear height. Supplying and fixing 900x800x60 mm size precast RCC slab of cement concrete 1:2:4 Supplying and fixing 1200x900x90 mm size precast RCC slab of cement concrete 1:2:4 Providing and fixing MS foot rest including fixing in manholes with 200x200x100mm CC block 1:3:6 as per the std design with 20mm dia round bar. Providing and fixing Urinal partition of 1200x600x25mm thk cudappa stone both sides polished incl fixing in wall etc complete. Providing /fixing Merino urinal partition for the toilets, including all necessary fixtures , etc
UNIT
RM EA
NEW NEW NEW NEW 7007342 7007343 7007344 7007345 7007346 25 NEW 7007350 26 27
01 02 03 04 05 06 07 08 09
RM RM RM RM RM RM RM RM RM RM EA
1540 1540 1540 1540 187.5 225 325 400 775 1540 562.5 #N/A
110 120 130 140 150 180 260 320 620 4250 450
450
7007351 7007352
01 02
EA EA EA EA EA
EA EA EA
70 150 800
70 150 650
7007358 32
EA
4062.5
3250
3250
EA EA EA EA EA
Page 16 of 111
SERVICE NO 38
DESCRIPTION OF WORK Supplying & lowering salt glazed stone ware pipes & specials into trenches for all depths and laying out the same to correct alignment; gradient; levels etc. in trenches incl. all dressing and trimming of bed & side of trenches; if required; trimming & cutting of concrete beds & joint holes; supporting the pipes & specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching; haunching and envelopes are completed. The sewer shall rest on the bed at every point throughout its length and to ensure this it shall be grouted in with cement mortar 1:3 incl. the cost of the jointing & fixing the pipes and specials in trenches using cement mortar 1:1 & best white spun yarn.item includes excavation and back filling etc. complete as directed. 01 02 03 04 05 39 75mm 100mm 150mm 200mm 230 mm Constructing 230mm thick brick masonry walls for septic tank as per standard drawing. The job includes excavation;sand filling; cement concrete foundation; plastering (1:3CM) of internal walls with waterproofing compound;plastering 1:4 CM external wall; on top and sides upto230mm below finished formation ground level and also incl. CI manhole cover over septic tank; inlet/ outlet chambers;3M long 65mm dia AC vent pipe with AC cover/fixed to the roof slope of the septic tank. 15 users 30 users 50 users 100 users Construction of 2.5 m dia & 3m deep soak pit incl.with top slab as above . Ref std drg for 50 persons usage. Construction of Water Tank of inner size 5.0 x 1.20 x 1.20. Job includes excavation in ordinary soil, laying of 150mm thk PCC 1:3:6, 150mm thk CC 1:2:4 with 1% reinforcement by volume Brick Masonry with CM 1:5 and Plaster with coarse sand in CM 1:4( with water proofing compound of 1kg in 5O kg of cement) & fixing of glazed tiles on walls. Also laying of 200mm Top slab in CC 1:2:4 with 2% reinforcement and fixing of 2nos 600 x 600mm size manholes made out of 16mm thk MS Plate & Angle 50 x 50 x 6 complete.With mats/labour Supplying and fixing 65mm dia 3.5M long PVC vent pipe over manhole chambers incl. providing PVC cowl on top. Supplying and fixing ductile iron chamber covers of approved make (on driveway) for tank manhole/dip/fill chambers or cable chamers on driveway including cost of frames, cover all material, labour, transportation etc complete. CHAMBER COVERS - 900 x 900 (NECO or equivalent ) CHAMBER COVERS - 750X750 (NECO or equivalent ) CHAMBER COVERS - 300X300 (NECO or equivalent ) Charges for connecting water pipes to the water tank. Providing/fixing CI gratings of 25mm thick & 300mm wide600mm long incl. S/F MS angle iron frame 40mmX6mm size in CC 1:2:4 bedding. Constructing brick masonary inspection chamber sizes as given below upto 0.60 M average depth in cement mortar 1:6, cement concrete 1:3:6 75mm thick in foundation, cement conc.1:2:4 50mm thick benching,12mm thick cement plaster 1:2 with floating coat of 1mm thk. of neat cement, 50 mm thick CC toping etc. size 450 x 450 mm size 600 x 600 mm size 600 x 750 mm size 750 x 750 mm size 900 x 900 mm Providing 100 mm thick slab with RCC 1:1.5:3 suitable for the following chambers. size 450 x 450 mm size 600 x 600 mm
Page 17 of 111
UNIT
OLD SOR
RM RM RM RM RM
EA EA EA EA EA EA
18000
6000
7007371 42 43
EA
500 #N/A
400
400
EA EA EA EA KG
01 02 03 04 05 01 02
EA EA EA EA EA EA EA
DESCRIPTION OF WORK size 600 x 750 mm size 750 x 750 mm size 900 x 900 mm S/F heavy duty C.I. cover & frame suitable to the following sizes inspection chambers,weight as per BIS Specifications painted with 3 coats of black bitumastic superior paint / enamel paint as approved. size 450 x 450 mm size 600 x 600 mm size 600 x 750 mm size 750 x 750 mm size 900 x 900 mm and of reqd size. Payment shall be as per weight P&F in position best Indian make 25 dia CP brass adjustable towel rails fixed in with rawl plugs embedded in walls with CP brass screws complete in all respect incl. Cutting &making good the walls etc. 750 mm long 600 mm long Supplying/fixing Towel rail Jaguar make or equivalent in toilet, including necessary fixtures etc., complete. Supplying/fixing Towel ring Jaguar make or equivalent in toilets AUTOMATIC SENSOR of good reputed make and quality as approved by the engg incharge, For water pumps for automatic starting and stopping of water pumps, including cost of all wiring, necessary panels etc complete. Providing and fixing screwed gate valve with CI wheel of approved quality. 20 mm nominal bore 25 mm nominal bore 32 mm nominal bore 40 mm nominal bore High or low pressure float valve with plastic float for 15 mm nominal bore 20 mm nominal bore Providing and fixing brass ferrule with CI cover including boring and tapping the main. With 15 mm nominal bore With 25 mm nominal bore Providing and fixing injection moulded PVC 'SWR' pipe for external drainage including fittings; cowls & fixing pipe with clamps etc. 65 mm dia 75 mm dia 110 mm dia. 150mm dia. Providing and laying unplasticised polyvinyl chloride (UPVC) pipes conforming to IS:4985 including all necessary fittings conforming to IS/BS 4514 and other accessories including connections etc. complete as per drawings. 90 mm dia 4 kg Sq.cm 110 mm dia 4 kg Sq.cm 160 mm dia 4 kg Sq.cm 250 mm dia 4 kg Sq.cm Supplying and laying "B" class G.I. pipeline incl. cutting threading; testing for water/air complete with fittings like couplings; tees; nipples and elbows incl. the excavation/ backfilling the trench and also along the wall with the necessary fittings : GST, TATA with R Brand fittings 12mm 19mm 25mm 40mm dia dia dia dia
Page 18 of 111
UNIT EA EA EA
01 02 03 04 05 06
EA EA EA EA EA KG
EA EA EA EA Set
300 275
400
53 7007392 7007393 7007394 7007395 54 7007397 7007398 55 7007399 7007400 56 7007401 7007402 7007403 7007404 57 01 02 03 04 01 02 01 02 01 02 03 04
EA EA EA EA EA EA EA EA
#N/A 287.5 350 387.5 537.5 #N/A 812.5 1125 #N/A 1125 1406.25 #N/A 187.5 225 250 375 #N/A
RM RM RM RM
01 02 03 04
RM RM RM RM
01 02 03 04
RM RM RM RM
SERVICE NO NEW 59
DESCRIPTION OF WORK 100mm dia Laying the supplied GI pipe for water/air incl. cutting,threading, testing excavating backfilling and also along the wall with the fittings. Rate including the cost of the necessary fittings like coupling, elbow, tee, nipple complete." with R Brand fittings 12 MM 20 MM 25MM 40 MM Supplying and fixing pipeline fittings G.I. 12 mm dia ELBOW 12MM UNION 12MM ELBOW 25MM UNION 25MM ELBOW 40MM UNION 40MM Providing and fixing High density PVC pipes with PVC fittings and clamps. Complete as per drawings including cutting and making good the walls and floor wherever required.(internal work) 15mm nominal bore 20mm nominal bore 25mm nominal bore 32mm nominal bore 40mm nominal bore Supplying and fixing heavy type CP brass stop cock (Essco or equivalent) 12 mm size 19 mm size 25 mm size Supplying and fixing wheel valve "GG" or equiv. heavy duty 12 mm size 19 mm size 25 mm size 40 mm size Providing float/ball valve to water/flush tank 12 mm size 19 mm size 25 mm size Supplying and fixing heavy type CP brass bib cock (Essco or equiv.) 12 mm size crown type 12 mm size pillar type 12mm size long body type Supplying and fixing PVC/CI cowl for sanitary vent pipe 75mm dia 100mm dia Removing tank after dismantling pipelines and stacking same Tank of 500-1000 ltrs. Capacity Tank of 1200-3000 ltrs. capacity Tank of 3200-5000 ltrs. capacity Supplying and fixing 32mm dia PVC water pipes for washbasin of required length with necessary CP brass cap and union etc. complete. Supplying and fixing 12mm PVC flexible water inlet pipes of required length with brass union; etc. for connection from water line to wash basin. Supplying and fixing Syntex/infra water tanks incl. cost of necessary fittings for inflow/outflow/overflow of waterexcl. the cost of ladder. 500 ltrs. capacity 1000 ltrs. capacity
Page 19 of 111
UNIT RM
725
7007413 7007414 7007415 7007416 60 7007417 7007418 7007419 7007420 7007421 7007422 61
01 02 03 04 01 02 03 04 05 06
RM RM RM RM EA EA EA EA EA EA
87.5 100 112.5 125 #N/A 40 118.75 68.75 156.25 131.25 312.5 #N/A
7007423 7007424 7007425 7007426 7007427 62 7007428 7007429 7007430 63 7007431 7007432 7007433 7007434 64 7007435 7007436 7007437 65 7007438 7007439 7007440 66 7007441 7007442 67 7007443 7007444 7007445 68 7007446 69 7007447 70 7007448 7007449
01 02 03 04 05 01 02 03 01 02 03 04 01 02 03 01 02 03 01 02 01 02 03
RM RM RM RM RM EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA
118.75 137.5 162.5 187.5 218.75 #N/A 587.5 650 718.75 #N/A 450 512.5 575 900 #N/A 350 425 562.5 #N/A 781.25 843.75 906.25 #N/A 125 150 #N/A 500 750 937.5 262.5 137.5 #N/A
95 110 130 150 175 470 520 575 360 410 460 720 280 340 450 625 675 725 100 120 400 600 750 210 110
95 110 130 150 175 450 500 550 350 400 450 700 275 325 450 600 650 700 100 120 400 600 750 200 100
01 02
EA EA
3750 7500
3000 6000
3000 6000
DESCRIPTION OF WORK 2000 ltrs. capacity 5000 ltrs capacity Supplying and fixing syntex water tanks incl. cost of necessary fittings for inflow/outflow/overflow of waterexcl. the cost of ladder. Supplying & laying RCC hume pipe of NP2 class in trenches for drainage/culverts including colors & filling the joints with Shun gasket & cement.The cost is excluding excavation of earth. 100 mm dia 150 mm dia 200 mm dia 300 mm dia 450 mm dia 600 mm dia 900 mm dia 1000 mm dia Supplying & laying RCC hume pipe of NP3 class in trenches for drainage/culverts including colors & filling the joints with Shun gasket & cement.The cost is excluding excavation of earth. 200 mm dia 300 mm dia 450 mm dia 600 mm dia 900 mm dia 1000 mm dia 1200 mm dia FENCING/BOUNDARY WALL Dismantling barbed wire fencing incl. removing angle iron posts from CC foundation rolling up barbed wire and stacking Upto 1.8 m height Upto 1.35 m height Supplying and fixing precast RCC fencing post only of avg.size 100mm X 100mm suitable for following height fencing from GL and fixing in CC foundation 1:3:6 complete as per drawing. 1.8 m high fencing 1.35 m high fencing Supplying and fixing angle iron post only size 50X50X6 in cc foundation 1:3:6 suitable for following height fencing as per drawing. 1.8 m high fencing 1.35 m high fencing Dismantling BM compound wall upto ground level and disposing debris outside the premises to an unobjectionable area or spreading/levelling within the site as directed. 1.8 m high wall 1.35 m high wall Tightening the loose Barbed Wire incl. providing and fixing necessary hooks/clamps etc. complete. Dismantling and removing existing Barbed Wire fencing and supplying; fixing new GI barbed wire (12 SWG with 4 points) strand (horizontal; vertical; diagonal) along with necessary clamps; hooks; bolts etc. incl. cost of new barbed wire. Supplying and fixing GI barbed wire (12 SWG with 4 points) strand (horizontal; vertical; diagonal) to the existing fencing wherever necessary as instructed complete incl. Hooks; bolts; clamps etc.
UNIT EA EA LTR
12000 20000
01 02 03 04 05 06 07 08
RM RM RM RM RM RM RM RM
01 02 03 04 05 06 07
RM RM RM RM RM RM RM
687.5 812.5 1625 2875 4625 4875 5250 #N/A #N/A 33.6 28 #N/A
01 02
RM RM
30 25
30 25
01 02
EA EA
280 246.4 #N/A 616 504 #N/A 112 89.6 5.6 26.88
250 220
250 220
01 02
EA EA
550 450
550 450
01 02
RM RM RM RM
100 80 5 24
100 80 5 24
7006825 7
RM
22.4
20
20
Page 20 of 111
SERVICE NO 8
DESCRIPTION OF WORK Supplying & fixing/ erecting GI barbed wire fencing(12 SWG with 4 points on angle iron posts at approximately 2.5m centre to centre distance; embeded in CC 1:3:6 as per our standard drawing incl. cost of steel,curing the concrete; painting angle iron posts with 2 coats of each of Red Oxide primer and aluminium paint complete for the following heights for size of angle iron and any other details refer standard drawing. 1.8 m high from Gr. level with 7 horizontal; 2 diagonal and vertical strands 1.35 m high from Gr. level with 5 horizontal; 2 diagonal and vertical strands Supplying & fixing/ erecting GI barbed wire fencing(12 SWG with 4 points on RCC precast post of 100 X 100mm avg. size instead of angle iron posts at approx. 2.5m centre to centre distance; embedded in CC 1:3:6 as per our standard drawing incl. curing the concrete. 1.8 m high 1.35 m high Supplying and erecting chainlink fencing with 2nos. 4mm GI straining wire on the following heights of angle iron posts at approximately 2.5m centre to centre embedded in CC 1:3:6as per our standard drawing no E.1S.01.001 incl. Providing 3 strands GI barbed wire 12 SWG with 4 points on 0.4m high bent arm on top of angle iron posts incl. painting vertical post with 2coats each of Red oxide and aluminium paint. 1.8m high 1.35m high Supplying and erecting chainlink fencing with 2nos. 4mm GI straining wire on the following heights of angle iron posts at approximately 2.5m centre to centre embedded in CC 1:3:6as per our standard drawing no E.1S.01.001 incl. painting vertical post with 2coats each of Red oxide and aluminium paint. 1.8m high 1.35m high Supplying and erecting PVC coated chainlink fencing with 2nos. 4mm GI straining wire on the following heights of angle iron posts at approximately 2.5m centre to centre embedded in CC 1:3:6as per our standard drawing no E.1S.01.001I incl. painting vertical post with 2coats each of Red oxide and aluminium paint. 1.8m high 1.35m high Dismantling of structures and removing debris away from site and stocking salvageable materials as directed Chainlink fencing Barbed wire fencing Dismantling broken RCC post/angle iron post incl. Breaking foundation. Removing of existing scale proof fencing (angle iron posts and barbed wire) and stacking the material inside depot as directed. Providing & fixing 610mm high scale proof fencing on wall incl. cost of GI barbed wire 12 gauge (7 horizontal,2 strands diagonal) tightening arrangement @3000 C/C incl. CC blocks size 150X150X230 & Aluminium painting etc. Drg no. E.1S.01.0011. Painting barbed wire strands of size 12 SWG inclusive of angle iron posts with two coats of Aluminium paint incl.cost of paint etc. complete incl. one coat of Red oxideprimer. ROAD WORK
UNIT
OLD SOR
7006826 7006827 9
01 02
RM RM
425 375
400 350
7006828 7006829 10
01 02
RM RM
425 375
400 350
7006830 7006831 11
01 02
RM RM
720 620
700 600
7006832 7006833 12
01 02
RM RM
620 520
600 500
01 02
RM RM
700 600
700 600
01 02 03 04
RM RM EA RM RM
21 16 32 42 420
20 15 30 40 400
7006841 15
M2
67.2 #N/A
60
55
Page 21 of 111
SERVICE NO 1
DESCRIPTION OF WORK Supplying and spreading stone aggregate of required size as per our specification in 2 layers to achieve the required thickness as mentioned below, followed by supplying and spreading 20mm down stone aggregate to fill voids,re-rolling the same with 8 - 10 ton roller, followed by supplying and spreading murrum or quarry dust or approved quality earth, consolidating the same with optimum water moisture till the surface is evenly and densely consolidate to achieve. NOTE : Please note that each layer of stone aggregate has to be consolidated with 8 - 10 ton roller. During the murrum filling, watering should be done per each run of the roller and minimum 5 such runs have to be undertaken on subgrade. During each such sun if any void is observed after watering the same shall be filled using 1:1mix of 20 mm metal of murrum. The spreading of murrum,sprinkling of water, sweeping with a broom and rolling shall continue until the slurry that is formed well after filling the voids formed ahead of the wheels of the moving roller and any undulations in the surface developed due to rolling shall be made good. The rates should be inclusive of all cost of equipment, material, labour etc. 230mm thick compacted WBM using stone aggregate of size75-100mm 150 mm thick compacted WBM using stone aggregate of size 50- 75 mm 100 mm thick compacted WBM using stone aggregate of size 40- 63 mm 75 mm thick compacted WBM using stone aggregate of size 40-63 mm Supplying,spreading compacting 1st class brick bats/jhamas metal of size 45MM to 80 MM in hand crust to requisite thickness(measured after compaction) including screening of bats/metals etc as necessary, hand packing ,sweeping watering and rolling in stages with power roller to proper line, grade and camber lighting. Guarding and barricading and making necessary earthen bund of 1 m width on each side, where necessary to protect edges including cost of all meterial, complete. 100 mm compacted thickness 150 mm compacted thickness 200 mm compacted thickness Supplying,spreading compacting 1st class brick bats/jhamas metal of size 75 MM in 2 layers hand crust to a thickness of 150mm (measured after compaction) including screening of bats/metals etc as necessary, hand packing ,sweeping watering and rolling in stages with power roller to proper line, grade and camber lighting. Guarding and barricading and making necessary earthen bund of 1 m width on each side, where necessary to protect edges including cost of all meterial, complete.
UNIT
OLD SOR
#N/A M2 M2 M2 M2 375 240 #N/A 1540 #N/A 280 190 110 250 170 110
01 02 03 04
01 02 03
M2 M2 M2 M2
7007259 4
NEW
NEW
Repair of pot holes or patches or ruts in WBM base or existing driveway by removing loose and M2 defective materials by cutting in rectangular patches to a minimum depth of 50mm and replacing the same with premix carpet prepared using stone metal size 20mm & 60mm and Bitumen(grade 30/40)at 56 Kg./cu.m. after applying tackcoat on consolidating the repaired surface shall match the surrounding driveway level. The excavated material shall be disposed off as directed by the Engineer I/C. Rate includes cost of material and labour complete cu.m Drainage Layer : Providing drainage layer using the following materials : Supplying and spreading crushed aggregate for 150 mm thick layer comprising of aggregate size of 26.5 mm with percentage weight passing the IS seive 55 -75 %, 4.75 mm with percentage passing on designated sieve 1030% and particles finer than 0.075 mm of less than 5%.( Particles finer than 0.075 mm should be less than 5%) cu.m Construction of Granular sub base by providing ,laying, spreading,and compacting coarse graded material , spreading in uniform layers with motor grader on prepared surface,mixing by mix in place method with rotavator at OMCand compacting with vibratory roller of 80 KN to 100 KN to achieve the desired density of 98% including protection of edges of GSB layer,Cost of materials,labour,hirecharges of machinery,lighting,guarding,barricading,loading and unloading etc complete. - Detailed Specifications as attached.
215
165
140
1540
950
1000
1540
1100
1000
Page 22 of 111
SERVICE NO 9005061 7
DESCRIPTION OF WORK WET MIX MECADAM : Providing ,Laying, spreading and compacting graded stone aggregates (Table 400.11 of MORTH) of wet mix macadam specification including cost transportaion of all materials including premixing the material with water at OMC (Optimum Moisture Content) in mechanical mix plant ,carriage of mixed materials by tipper to the site, laying in uniform layers with paver in base courses on well prepared surfaces and compacting with vibratory roller of 80 KN to 100 KNto achive the desired density of 98%including protection of edges of WMM layer,cost of materials labour ,hire charges for machinery including loading and unloading and all leads of mixed material (compacted thickness 150 MM).- Detailed spec for materials, attached. Providing and laying 60mm metal and 40mm metal specified to a thickness and compacting the same to the engineer's satisfaction with a roller weighing not less than 10 ton Supplying and spreading 50mm metal levelling and consolidating (one layer) by roller Supplying and spreading 37mm metal levelling and consolidating (one layer) by 8-10T roller Providing and laying SOLING 225mm thick (compacted thickness using boulders of approved quality, as close as possible,,,hand packing with stone chippings to fill the voids, laying murrum, ramming, watering, well consolidating with 10 MT roller complete as per specifications, drawings and instructions. Providing and laying base course using 150mm to 230mm thick soling stones incl. levelling and consolidation by 8 to 10ton road roller etc. complete. Providing and laying pitching using good quality bricks laid flat as directed by site engineer. Rate includes levelling/preparation of surface, pointing with CM 1:3 and done in the locally prevalent method. The finished surface should give a good aesthetic look Providing and laying pitching using good quality laterite laid flat as directed by site engineer. Rate includes levelling/preparation of surface, pointing with CM 1:3 and done in the locally prevalent method. The finished surface should give a good aesthetic look Providing and laying pitching using good quality stone blocks as directed by site engineer. Rate includes levelling/preparation of surface, pointing with CM 1:3 and done in the locally prevalent method. The finished surface should give a good aesthetic look Providing & laying metal as per specified thickness & compacting the same to the satisfaction of the Engineer with a roller not lessthan10 tons & grouting the same by spraying 60/70 bitumen at 708kg/100 sq m & spreading 12 mm metal at the rate of 2.10Cu m/110 sqm rolling with 10 ton roller. Providing a second coat of 60/100 asphalt @ 122-147 kg/ 100 sq m & rolling the same after spreading 6 mm grit @ 1 cu m per 100 sq. m giving smooth surface complete as specified & as directed. ( Spraying by pressure distributor,handpouring not permitted.) 01 02 17 of 50mm Thickness using 40-25mm metal of 100mm thickness using 60-40mm metal Premix Carpet : Cleaning the existing surface with wirebrush & removing all lose aggregate & traces of fine dust which get accumulated while brushing fine dust shall be removed from the surface by blowing with gunny bag or any other means as approved by the engineer.Tack Coat : Bitumen shall be heated to a temp. as specified for the grade used and maintained at that temp. for the specified duration (even for premix & seal coat bitumen should be heated as specified above) The tack coat shall be applied evenly using 1Kg/sq m of bitumen over cleaned/dry surface by means of pressure distributor/sprayer or any other means. The binder shall be applied longitudenally along the length of the road & never across it. Premix Carpet : Spreading pre mix stone aggregate of 10 mm size to a required thickness . Stone aggregate shall be mixed with bitumen (grade 30/40) 56kg/Cu m. Spreading shall be done evenly to obtain a uniform surface. Road surface shall be compacted by 10 ton roller immediately after spreading the premix.
UNIT cu.m
1350
M3 M2 M2 M2
1000 65 74 247
800 50 57 190
750 45 55 160
7007263 12 7007264 13
M3 M2
900 270
725 210
700 200
NEW 14
M2
1540
525
750
7007265 15
M2
330
260
260
16
#N/A
7007266 7007267
M2 M2
260 375
250 350
Page 23 of 111
SERVICE NO
DESCRIPTION OF WORK Rolling shall be started at edges & worked towards center. Each pass of roller shall uniformly overlap not less than 1/3rd of the track made by earlier pass. Usually5-6 runs shall be made for compacting surface. Along curbs manholes & all other places not accessible to the roller shall be compacted by means of steel rammers.Seal Coat: Providing 12mm thick seal coat using sand precoated with bitumen 1kg/sq.m. dry & bitumen should be thoroughly mixed to have uniform mix. The rolling shall be done as explained above. Rates include cost of all material,labour,equipment etc. complete.
UNIT
OLD SOR
7007268 7007269 18
01 02
20
25mm Premix carpet 50mm Premix carpet Seal Coat: Providing seal coat using sand/6mm grit precoated with bitumen & bitumen should be thoroughly mixed to have uniform mix. The rolling shall be done as explained above. Rates include cost of all material,labour,equipment etc. complete. 12mm seal coat with bitumen 1Kg/Sqm 18mm seal coat with bitumen 1.5Kg/Sqm 25mm seal coat with bitumen 2Kg/Sqm Providing & laying sand seal coat using coarse sand and 80 / 100 grade bitumen @ 100 kg per Cum of sand. Spreaded in 5 mm thickness & rolled to give a smooth finish incl cost of material & labour etc. complete. Providing and laying CC of required thickness for driveways in panels I/c formwork, curing, Providing Groove cutting on RCC driveway by marking the line wherever required with permanent marker pen, cutting the concrete floor to the required width & Depth ( 3mm X 25mm). The job also includes cleaning the groove thoroughly with air blower,and filling the same with 10/20 grade bitumen sealing compound inclusive of cost of all material labour equipment etc. using cc mix 1:1.5:3 but wihout using tremix vacuum dewatering system and power trowel using cc mix 1:2:4 but without using tremix vacuum dewatering system and power trowel Extra for using tremix vacuum dewatering system and power trowel Providing and placing 20mm thick Shalitex or equivalent board for cement concrete driveway joints I/c filling the top 25mm depth Tikitar joints filler. Providing and laying bitumen jointing in the expansion joint RCC driveway. Dismantling the cracked CC apron 175mm thick and carting away the debris. Affixing masking tape on both sides of joints, mixing two part Elestomeric polysulphide / Thioflex 600 gg sealant (FOSROC or Equivalent) and fill up the same to the required width & Depth. Removing the masking tape and finish the sealant as required. Supplying & laying CC paver blocks 60mm thick using minimum M 35 grade laid on 50mm avg thickness sand bedding. Supplying & laying CC paver blocks 80mm thick using minimum M 35 grade laid on 50mm avg thickness sand bedding(maximum quantity to be restricted to 100 Sqm) Paver blocks to be procured from BPCL approved manufacturers. Supplying & fixing kerb slabs using CC blocks 50 MM thick Removing and relaying supplied old Paver block of all thickness & sizes incl. Laying 50 mm bed of coarse sand, filling sand in joints & compacting with vibrator etc. complete Removing and relaying supplied old Paver blocks of all thockness & sizes incl. Filling sand in joints & compacting with vibrator etc. complete.(existing sand bed to be used). KERB WALL using Pre cast Kerb Stones- Providing Kerb Wall by Supplying & fixing kerb stone of required size to suit the site conditions, with CC 1:2:4 using 20mm metal incl. necessary joints between the blocks, The surface to have a smooth finish. (Excluding the cost of excavation & PCC) a. 450mm depth x 150mm thick b. 350mm depth x 150mm thick a. 450mm depth x 125mm thick b. 350mm depth x 125mm thick Coloured Paver block - Supplying & laying CC paver blocks 80mm thick using minimum M 35 grade laid on 50mm avg thickness sand bedding Paver blocks to be procured from BPCL approved manufacturers.
Page 24 of 111
M2 M2
175 300
150 250
M2 M2 M2 M2
88 #N/A #N/A 55
70
45
50 65 90 40
#N/A
M3 M3 M2 M2 M M2 M
7007287 25 7007288 26
M2 M2
400 475
M2 M2 M2
300 120 70
275 110 60
01 02 03 04
RM RM RM RM
DESCRIPTION OF WORK Rubber mould reflective pavers Normal surface pavers with color pigment on top EMBLEM POLE & SIGNAGES Dismantling emblem pole after disconnecting electrical/earthing Connecting incl. Filling, leveling the pit with earth and stacking the pole within the site as directed: Italian type Pedestal type Glowsign Emblem Post Monolith Erecting supplied Glow Sign emblem poles on CC foundation as per drg. including sign using crane or chain pulley. ( Cost of foundation will be paid separately) Providing foundation for Emblem pole as per std drg. and specification including cost of foundation bolts and labour complete Providing wiring of emblem pole internally with 3/20 PVC insulated copper wire of approved make complete. Providing 3/20 PVC insulated copper wire of approved make with necessary connections for rewiring tube light fitting in emblem sign. Providing wiring of emblem pole internally with 3/20 PVC insulated copper wire of approved make complete Providing 3/20 PVC insulated copper wire of approved make with necessary connections for rewiring tube light fitting in emblem sign Erecting supplied monolith as per drg. Including signboards using crane or chain pully. ( Cost of foundation will be paid separately) Providing foundation for monolith as per std drg. and specification including cost of foundation bolts and labour complete. Providing 3/20 PVC insulated copper wire of approved make with necessary connections for rewiring tube light fitting in monolith- for each tube light Erecting/fixing following supplied items incl. Cost of concreting, labour, hardware and making electrical connections complete. PFS Signage Mini Monolith(Facility Board) Entry / Exit / No Smoking signs Air/Water sign pump spreaders. Wall mounted emblem sign Automatic tyre tower Replacing the Vinyl film on the emblem sign as per specification completebut excluding polycarbonate sheet. Rate per side Cleaning canopy with soft cloth soap solution and water incl of ladders / transportation etc. Complete to remove all dirt/dust , bird droppings etc. Followed by wiping with wet soft cloth / sponge to remove all residual soap. Finally wiping dry with dry soft cloth/sponge." Cleaning The Panaflex / Polycarbonate Glow box facia as above Cleaning Glow Signs incl opening the polycarbonate sheets and refitting as above Cleaning Monoliths.(both sides) as above BORE WELL BORE WELL Supplying, handling, fitting 150mm dia UPVC pipe conforming to IS:12818 of reputed make and lowering including providing.transporting of pipes, fittings, accessories like drill plug with lock at bottom, well cap etc. completed Blind pipe slotted pipe Supplying, handling, fitting 150mm dia MS pipe conforming to IS:12818 of reputed make and lowering including providing.transporting of pipes, fittings, accessories like drill plug with lock at bottom, well cap etc. completed
Page 25 of 111
UNIT M2 M2
New SOR 1540 1540 #N/A #N/A #N/A #N/A #N/A 2300 3450 3220 7475 #N/A
700 625
EA EA EA EA EA EA
EA #N/A EA EA EA EA 460 126.5 5175 #N/A EA #N/A EA #N/A EA EA EA EA EA EA EA EA M2 1207.5 1150 690 690 690 632.5 632.5 1540 24.15
8000545 6 8000546 7 7007474 8 7007475 7007476 8 9 10 7007477 7007478 7007479 7007480 7007481 7007482 7007483 NEW 11 7007485 12 01 02 03 04 05 06 07
M2 EA EA M
7006191 7006192 3
01 02
M M
450 475
450 475
DESCRIPTION OF WORK Blind pipe slotted pipe Carrying out electrologging for determining the exact location of saline zone etc. complete Supplying submersible pump of 7.5 HP 15 stage (KSB or equivalent approved make) suitable for 150 mm dia borewell with electric control panel and fittings Supplying submersible pump of 5.0 HP 15 stage (KSB or equivalent approved make) suitable for 150 mm dia borewell with electric control panel and fittings Supplying submersible pump of 3.0 HP (KSB or equivalent approved make) suitable for 150 mm dia borewell with electric control panel and fittings Supplying submersible pump of 1.0 HP (KSB or equivalent approved make) suitable for 150 mm dia borewell with electric control panel and fittings Supplying and laying PVC armoured ISI approved water proof cable of reputed make of 3c x 4 sqmm (copper conductor) with necessary fittings. The cable should be laid from submersible pump (ground level to electric panel (in PVC pipe of 2 In. dia) Supplying cable 2.5 sqmm x 3 core flat cable of approved make for submersible pump) Supplying and lowering 50 mm dia GI class 'C' pipe (in the submersible pump) of approved make with long coupling 50 mm dia including cutting, threading all fittings and testing it to suitable pressure. The pipe should be installed from pump upto the ground level incl. necessary gate valves, non return valve, column pipe ben piece, coupling, clamp and nut bolts etc. complete. Collection of water sample and getting it tested at appoved laboratory for the potability and submission of reports etc. all complete Supplying and fixing monoblock centrifugal pump including pipeline / electric connection complete 01 02 03 14 0.5 HP 1 HP 2 HP Supply, laying, PVC HD PIPE AS PER STANDARED AND SPECIFICATION FOR BORE WELL & ELECTRICAL 50MM DIA FOR BORE WELL & ELECTRICAL 75MM DIA FOR BORE WELL & ELECTRICAL 100MM DIA FOR BORE WELL & ELECTRICAL 150MM DIA Supplying and fixing Jet pump including pipeline / electric connection complete 1 HP 1.5 HP Supplying and fixing Submersible pump, Centrifugal including pipeline / electric connection complete. 1.5 HP 2 HP 5 HP ELECTRICAL Supplying and fixing 100/120 MRD condenser incl. makingelec. connection. Rewiring the dispensing pumps with 3/20 PVC insulated copper wire and approved quality 20mm GI pipe with fittings complete. Mono Pump Duo Pump Rewiring the dispensing pumps with 3/20 PVC insulated copper wire and approved quality 20mm GI pipe with fittings complete using existing conduit pipe in the pump Mono Pump Duo Pump Charges for attending electronic complaint Charges for attending electrical complaint Charges for attending mechanical break down complaints at retail outlet on emergency i). Ist Unit ii). IInd Unit
Page 26 of 111
UNIT M M LS EA EA EA EA M
New SOR 1540 1540 2587.5 42550 1540 25300 19500 103.5
7006201 9 7006202 10
M M
86.25 460
75 400
75 400
7006203 11 12 7006204 7006205 7006206 NEW NEW NEW NEW 15 8000548 8000549 16 8000550 8000551 8000552 7006364 1 2 7006365 7006366 3 7006367 7006368 7006369 4 8000553 5 6 7006370 7006371 01 02 01 02 01 02 03 01 02
LS
1150 #N/A
1000
1000
EA EA EA RM RM RM RM EA EA
5750 7015 9257.5 #N/A 1540 1540 1540 1540 #N/A 11500 12650 #N/A 25300 28750 37950 #N/A 702 #N/A 643.2 702 #N/A 492 585.6 500 500 #N/A 700 150
EA EA EA EA
EA EA
536 585
550 600
EA EA EA EA EA EA
01 02
125
SERVICE NO 7 7006372 7006373 7006374 8000554 8000555 7006375 7006376 7006377 7006378 8 01 02 03 04 05 06 07 08 09
DESCRIPTION OF WORK SUPPLYING AND FIXING the following E-Prom IC on Control Card incl. Disconnecting/soldering etc. complete. IC( small - any) on Control Card LCD on display card (5 digits) incl. Dismantling, etc LCD on display card (4 digits) incl. Dismantling, etc. LCD on display card (6 digits) incl. Dismantling, etc. Power supply Transformer membrane switch for Rate/Sale indicator Lead Acid Cell 6V 10 A Hr. Unidirectional bearing for the sensor unit assembly incl.Of dismantling, reassembling" Rewinding motor coil (both running and starter coil)including disconnecting electrical / earthing connections dismantling motor from motor base, transporting to workshop and vice versa, refixing motor on base with proper pulley alignment / belt tension and making electrical connections." 1/3 H.P. 3/4 H.P. 1 H.P. Rewinding motor coil ( starter coil)including disconnecting electrical / earthing connections dismantling motor from motor base, transporting to workshop and vice versa, refixing motor on base with proper pulley alignment / belt tension and making electrical connections." 1/3 H.P. 3/4 H.P. 1 H.P. Rewinding motor coil ( running coil)including disconnecting electrical / earthing connections dismantling motor from motor base, transporting to workshop and vice versa, refixing motor on base with proper pulley alignment / belt tension and making electri 1/3 H.P. 3/4 H.P. 1 H.P. Replacing the old with new set(2 nos) of Ball Bearings of SKF or equivalent Replacing the old with new Switches including making electrical connections (Recom or equivalent make) Centrifugal Switch Micro Switch (Kaycee) Toggle Switch Replacing the old with new Keltron' make condenser incl. Making electrical connections; 60/80 mfd 80/100 mfd. 100/120 mfd. Carrying out cleaning , servicing and oiling of motor. Replacing motor including disconnecting electrical/earthing connections dismantling motor from motor base,refixing the new motor supplied by the company on base /making/electrical/earthing connections in proper alignment and belt tension.." Supplying and fitting following fitting either of Philips,Crompton or GEC make including all necessary arrangement to fix the same in emblem sign 1200mm x 40W fluorescent tube light (rod) 1200mm x 36W fluorescent tube light (rod) Cu Choke for 40/36 W tube light Open Cast choke for 40/36 W tube light HF/Low Losschoke for 40/36W tube Light Starter for tube light Tube holder for tube light Providing and fitting Bulb for sodium vapour lamp of Philips or GEC or WIPRO or Crompton or equivalent approved make including cost of material and labour 150 w
Page 27 of 111
UNIT EA EA EA EA EA EA EA EA EA
New SOR #N/A 1170 292.8 1755.6 1404 2164.8 936 877.2 702 877.2 #N/A
OLD SOR 975 244 1463 1170 1804 780 731 585 731 1000 250 1500 1200 1850 800 750 600 750
01 02
EA EA EA
01 02
EA EA EA
01 02 03
EA EA EA EA
#N/A #N/A #N/A 585.6 #N/A 205.2 321.6 205.2 #N/A #N/A 468 585.6 175.2 175.2
EA EA EA EA EA EA EA EA
#N/A EA EA EA EA EA EA EA 93.6 93.6 262.8 262.8 351.6 24 24 #N/A 1053.6 78 78 219 219 293 20 20 80 80 225 225 300 20 20
EA
878
900
SERVICE NO 7006405 7006406 18 7006407 7006408 7006409 19 7006410 7006411 7006412 20 7006413 7006414 7006415 21 7006416 7006417 7006418 22 8000556 8000557 8000558 23 7006419 7006420 7006421 24 NEW NEW NEW 25 7006422 01 7006423 02 7006424 03 7006425 26 7006426 27 28 01 02 03 01 02 03 01 02 03 01 02 03 01 02 03 02 03
DESCRIPTION OF WORK 250 w 400 w Providing and fitting Choke for sodium vapour lamp of Philips or GEC or WIPRO or Crompton or equivalent approved make including cost of material and labour 250 w 400 w Providing and fitting Ignitor for sodium vapour lamp of Philips or GEC or WIPRO or Crompton or equivalent approved make including cost of material and labour 150 w 250 w 400 w Providing and fitting Capacitor for sodium vapour lamp of Philips or GEC or WIPRO or Crompton or equivalent approved make including cost of material and labour 150 w 250 w 400 w Providing and fitting Bulb for Metal Helide lamp on CANOPY of Philips or GEC or WIPRO or Crompton or equivalent approved make including cost of material and labour 150 w 250 w el Providing and fitting choke for Metal Helide lamp on CANOPY of Philips or GEC or WIPRO or Crompton or equivalent approved make including cost of material and labour 150 w 250 w 400 w Providing and fitting Bulb for Metal Helide lamp on YARD LIGHTING of Philips or GEC or WIPRO or Crompton or equivalent approved make including cost of material and labour 150 w 250 w 400 w Providing and fitting choke for Metal Helide lamp on YARD LIGHTING of Philips or GEC or WIPRO or Crompton or equivalent approved make including cost of material and labour 150 w 250 w 400 w Providing and fitting super imposed Ignitor for Metal Helide lamp of Philips or GEC or WIPRO or Crompton or equivalent approved make including cost of material and labour 150 w 250 w 400 w Fitting Bulb for Metal Helide lamp in canopy of Philips or GEC or WIPRO or Crompton or equivalent approved make excluding cost of material ( labour cost only) Fitting Ignitor for Metal Helide lamp in canopy of Philips or GEC or WIPRO or Crompton or equivalent approved make excluding cost of material ( labour cost only) Fitting Bulb for sodium vapour lamp in light pole of approved make of Philips or GEC or WIPRO or Crompton or equivalent approved make excluding cost of materials (labour cost only) upto 5mtr height upto 7mtr height upto 10mtr height Fitting Choke for sodium vapour lamp in light pole of approved make of PHILIPS or GEC or WIPRO or Crompton or equivalent approved make excluding cost of materials (labour cost only)
UNIT EA EA
New SOR 1170 1287.6 #N/A 1638 1755.6 1989.6 #N/A 819.6 819.6 819.6 #N/A 468 468 468 #N/A 1755.6 1872 1872 #N/A 1755.6 1755.6 1872 #N/A 1755.6 1872 1872 #N/A 1540 1540 1540 #N/A 819.6 819.6 819.6 526.8 526.8 #N/A
975 1073
EA EA EA
EA EA EA
EA EA EA
EA EA EA
EA EA EA
EA EA EA
EA EA EA
EA EA EA EA EA
01 02 03
EA EA EA
Page 28 of 111
DESCRIPTION OF WORK upto 5mtr height upto 7mtr height upto 10mtr height Fitting Ignitor for sodium vapour lamp in light pole of approved make of Philips or GEC or WIPRO or Crompton or equivalent approved make excluding cost of materials (labour cost only) upto 5mtr height upto 7mtr height upto 10mtr height Fitting Capacitor for sodium vapour lamp in light pole of approved make of Philips or GEC or WIPRO or Crompton or equivalent approved make excluding cost of materials (labour cost only) upto 5mtr height upto 7mtr height upto 10mtr height Supplying fabricating erecting light pole in CC 1:3:6 ,painting the pole with two coats each of red oxide primer and approved make/shade/quality enamel paint complete excluding cost of foundation. (Height will be considered from finished driveway level ) Y Pole as per standard drawing Y Pole as per standard drawing 7mtr high single arm as per std drg. 7mtr high double arm as per std drg. 10 mtr high single arm as per std drg. 10 mtr high double arm as per std drg. Erecting supplied light pole in CC 1:3:6 including excavating in all types of soil as per our standard drg. and specification. upto 5mtr height upto 7mtr height upto 10mtr height Providing wiring of light/emblem pole internally with 3/20 PVC insulated copper wire of approved make and making necessary connections. upto 5 mtr height upto 7 mtr height upto 10 mtr height Dismantling S.V. light fitting from light pole and stacking as directed upto 5 mtr height upto 7 mtr height upto 10 mtr height Supplying and fixing weather proof junction box for emblem pole confirming to IS 2147 as per our standard drg. Co/R-54 and specification(cast AL with packing) (Baliga make only) 2 way 3 way 4 way Providing and fixing FLP Junction Box confirming to IS 2148 2 way 3 way 4 way Rates for supplying Electrical fittings as per ISI standard including fixing. 5 amps. piano switch (Anchor or Equivalent) 15 amps. piano switch (Anchor/or Equivalent) 30 amps. D.P. Switch Iron Clad Havels or Equivalent) 15 amps. D.P. Switch Iron Clad Havels or Equivalent) 32 amp. ICTP switch Havels or Equivalent) 16 amp. ICTP switch Havels or Equivalent)
UNIT EA EA EA
01 02 03
EA EA EA
01 02 03
EA EA EA
7006439 7006440 7006441 7006442 7006443 7006444 33 7006445 7006446 7006447 34 7006448 7006449 7006450 35 7006451 7006452 7006453 36 7006454 7006455 7006456 37 7006457 7006458 7006459 38 7006461 7006462 7006463 7006464 7006465 7006466
01 02 03 04 05 06
EA EA EA EA EA EA
7020 6435.6 8300 9200 10500 11500 #N/A 1872 2106 2574 #N/A 409.2 409.2 409.2 #N/A 409.2 409.2 409.2 #N/A 1300 1170 1170 #N/A 1600 1462.8 1462.8 #N/A 28.8 128.4 702 702 936 819.6
01 02 03
EA EA EA
01 02 03 01 02 03
EA EA EA EA EA EA
01 02 03 01 02 03 01 02 03 04 05 06
EA EA EA EA EA EA EA EA EA EA EA EA
975 975 975 1219 1219 1219 24 107 585 585 780 683
1000 1000 1000 1250 1250 1250 25 110 600 600 800 700
Page 29 of 111
SERVICE NO 39
DESCRIPTION OF WORK Supply,installation,testing and commissioning of prewired wall/ceiling/false ceiling mounted type HPF fluorescent light fixtures including providing and fixingtubes,chokes(5 to 5.5 WATT LOSS Maximum), starters,capacitors,earthing , connections and mounting arrangements etc. complete as required. 1x40W similar to Philips light fixture No.TMC 18/136 1x20W similar to Philips light fixture No.TBT 11/120 2x40W similar to Philips light fixture No.TCS 36/236 Dismantling light pole including light fixtures after disconnecting electrical/earthing connecting incl. filling,leveling the pit with earth and stacking the pole within the site as directed: upto 5.0 m height 5.00m to 10.0 m height Excavating trench 600mm deep, 450mm wide for laying cables ,supplying and Filling sand 75mm below the cable and brick protection on the top of the cable, back Filling to original shape, disposing of the surplus earth to out side the premises as follows In ordinary soil In WBM In bitumen surface In CC drive way In WBM with out redoing the surface In bitumen with out redoing the surface In CC drive way with out redoing the surface For laying only additional cable in the same trench Concealing armoured cable along runs on wall including grooving and replastering. Supply, laying, testing and commissioning of Aluminium Conductor cable PVC insulated PVC sheathed. 1100 V grade armoured cable in existing PVC conduit on walls / false ceiling / roof. Laid in cable tray with end termination's connections, earthing etc. complete as required 3.5 x 25 sq. mm 3.5 x 50 sq. mm 3.5 x 75 sq. mm 3.5 x 95 sq. mm 3.5 x125 sq. mm Supply, laying, testing and commissioning of Cu. Conductor power cable PVC insulated PVC sheathed. 1100 V grade armoured cable in existing PVC conduit on walls / false ceiling /roof. Laid in cable tray with end termination's connections, earthing etc. complete as required 6 x 2.5 sq. mm 2 x 1.5 sq. mm 3 x 1.5 sq. mm For laying only additional cable in the same trench 2 x 2.5 sq. mm 3 x 2.5 sq. mm 4 x 2.5 sq. mm 4 x 4 sq. mm 4 x 6 sq. mm 4 x10 sq. mm 4 x16 sq. mm 3.5 x 25 sq. mm 3.5 x 35 sq. mm Supplying laying following sizes Aluminium Conductor cable PVC of tropodour or equivalent approved make cable conforming to IS-1554 Along with termination both FLP and NON FLP excluding cost of cable glands but including fixing cable for dispensing pump, power, lighting circuits etc. job also includes dressing the cables testing, etc. Complete in the trench /hume pipe/PVC duct provided. (Excluding cost of trench / duct construction) 3.5 x 25 sq. mm
Page 30 of 111
UNIT
OLD SOR 0
01 02 03
EA EA EA
01 02
EA EA
700 900
01 02 03 04 05 06 07
RM RM RM RM RM RM RM M M
39 49 59 63 34 39 44 10 44 0
40 50 60 65 35 40 45 10 45
01 02 03 04 05
RM RM RM RM RM
7006486 7006487 7006488 7006489 7006490 7006491 7006492 7006493 7006494 7006495 7006496 7006497 7006498 46
01 02 03 04 05 06 07 08 09 10 11
M M M M M M M M M M M M M
222 94.8 117.6 140.4 117.6 140.4 175.2 258 362.4 514.8 789.6 #N/A #N/A #N/A
185 79 98 117 98 117 146 215 302 429 658 780 975 0
190 81 100 120 100 120 150 220 310 440 675 800 1000
7006499
01
216
180
185
DESCRIPTION OF WORK 3.5 x 50 sq. mm 3.5 x 75 sq. mm 3.5 x 95 sq. mm Supplying laying following sizes Cu. Conductor power cable PVC of tropodour or equivalent approved make cable conforming to IS-1554 Along with termination both FLP and NON FLP excluding cost of cable glands but including fixing cable for dispensing pump, power, lighting circuits etc. job also includes dressing the cables testing, etc.Complete in the trench/hume pipe/PVC duct provided. (Excluding cost of trench/duct construction) 6 x 2.5 sq. mm 2 x 1.5 sq. mm 3 x 1.5 sq. mm 4 x 1.5 sq. mm 2 x 2.5 sq. mm 3 x 2.5 sq. mm 4 x 2.5 sq. mm 4 x 4 sq. mm 4 x 6 sq. mm 4 x10 sq. mm 4 x16 sq. mm 3.5 x 25 sq. mm 3.5 x 35 sq. mm 3c X 4 Sq.mm. Supplying laying following sizes Aluminium Conductor cable PVC of tropodour or equivalent approved make cable conforming toIS-1554 Along with termination both FLP and non FLP excluding cost of cable glands but on wall incl making groove in the wall restoring the surface etc. or running on the wall with providing supporting 3.5 x 25 sq. mm 3.5 x 50 sq. mm 3.5 x 75 sq. mm 3.5 x 95 sq. mm Supplying laying following sizes Cu. Conductor power cable PVC of tropodour or equivalent approved make cable conforming to IS-1554 Along with termination both FLP and non FLP excluding cost of cable glands but on wall incl making groove in the wall restoring the surface etc. or running on the wall with providing supporting 6 x 2.5 sq. mm 2 x 1.5 sq. mm 3 x 1.5 sq. mm 4 x 1.5 sq. mm 2 x 2.5 sq. mm 3 x 2.5 sq. mm 4 x 2.5 sq. mm 4 x 4 sq. mm 4 x 6 sq. mm 4 x10 sq. mm 4 x16 sq. mm 3.5 x 25 sq. mm 3.5 x 35 sq. mm Excavating cable trenches for cable defect rectification and relaying including restoration of surface (excluding cost of cable).- In cable trenches under ground Excavating cable trenches for cable defect rectification for cables run through conduit pipes and relaying including restoration of surface (excluding cost of cable). Supplying approved make double comp flame proof cablegland with adaptor if required (Baliga or approved equivalent make)conforming to IS 2148 suitable for following cable size : 3.5 x 25 sq. mm 3.5 x 50 sq. mm
Page 31 of 111
UNIT M M M
7006503 7006504 7006505 7006506 7006507 7006508 7006509 7006510 7006511 7006512 7006513 7006514 7006515 7006516 48
01 02 03 04 05 06 07 08 09 10 11
12
M M M M M M M M M M M M M M
222 94.8 117.6 140.4 117.6 140.4 175.2 258 362.4 514.8 789.6 #N/A #N/A 262.8 #N/A
185 79 98 117 98 117 146 215 302 429 658 780 878 219
190 81 100 120 100 120 150 220 310 440 675 800 900 225
01 02 03 04
M M M M
7006521 7006522 7006523 7006524 7006525 7006526 7006527 7006528 7006529 7006530 7006531 7006532 7006533 7006534 50 7006535 51 52 7006536 7006537
01 02 03 04 05 06 07 08 09 10 11 12 13
M M M M M M M M M M M M M RM
222 94.8 117.6 140.4 117.6 140.4 175.2 258 362.4 514.8 789.6 #N/A #N/A #N/A #N/A
185 79 98 117 98 117 146 215 302 429 658 780 878 107 107
190 81 100 120 100 120 150 220 310 440 675 800 900 110 110
01 02
750 950
SERVICE NO 7006538 7006539 7006540 53 7006541 7006542 7006543 7006544 7006545 7006546 7006547 7006548 7006549 7006550 7006551 7006552 7006553 54 7006554 7006555 7006556 7006557 7006558 55 7006559 7006560 7006561 7006562 7006563 7006564 7006565 7006566 7006567 7006568 7006569 7006570 7006571 56 7006572 7006573 7006574 7006575 7006576 7006577 7006578 7006579 7006580 7006581 7006582 7006583 7006584 01 02 03 04 05 06 07 08 09 10 11 12 13 01 02 03 04 05 06 07 08 09 10 11 12 13 01 02 03 04 05 01 02 03 04 05 06 07 08 09 10 11 12 13 03 04 05
DESCRIPTION OF WORK 3.5 x 75 sq. mm 3.5 x 95 sq. mm 3.5 X 125 SQ MM Supplying flame proof double comp cable gland with adaptor if required (Baliga make or equivalent approved) conforming to IS 2148 suitable for following cable size : 6 x 2.5 sq. mm 2 x 1.5 sq. mm 3 x 1.5 sq. mm 4 x 1.5 sq. mm 2 x 2.5 sq. mm 3 x 2.5 sq. mm 4 x 2.5 sq. mm 4 x 4 sq. mm 4 x 6 sq. mm 4 x10 sq. mm 4 x16 sq. mm 3 x 25 sq. mm 3.5 x 35 sq. mm Supplying approved make quality commercial type cable glands suitable for following cable size (Baliga or equivalent make) 3.5 x 25 sq. mm 3.5 x 50 sq. mm 3.5 x 75 sq. mm 3.5 x 95 sq. mm 3.5X125 SQMM Supplying approved make quality commercial type cable glands suitable for following cable size : (Baliga or equivalent make) 6 x 2.5 sq. mm 2 x 1.5 sq. mm 3 x 1.5 sq. mm 4 x 1.5 sq. mm 2 x 2.5 sq. mm 3 x 2.5 sq. mm 4 x 2.5 sq. mm 4 x 4 sq. mm 4 x 6 sq. mm 4 x10 sq. mm 4 x16 sq. mm 3.5 x 25 sq. mm 3.5 x 35 sq. mm Supplying & fixing approved make cable jointing kit incl. Making connections, testing confirming to BIS std. suitable for following cable sizes: 4 x 25 sq.mm 4 x 50 sq.mm 4 x 75 sq.mm 4 x 95 sq.mm 4 x 125 sq.mm 2 x 1.5 sq.mm 3 x 1.5 sq.mm 4 x 1.5 sq.mm 2 x 2.5 sq.mm 3 x 2.5 sq.mm 4x 2.5 sq.mm 4x 4 sq.mm 4x 6 sq.mm
Page 32 of 111
UNIT EA EA EA
New SOR 1462.8 1462.8 2106 #N/A 468 351.6 351.6 351.6 351.6 468 468 468 526.8 526.8 585.6 936 994.8 #N/A 409.2 468 819.6 819.6 1053.6 #N/A 211.2 164.4 164.4 211.2 164.4 164.4 211.2 211.2 246 246 246 456 468 #N/A 1170 1404 1521.6 1755.6 2457.6 760.8 760.8 760.8 760.8 760.8 760.8 760.8 760.8
1219 1219 1755 0 390 293 293 293 293 390 390 390 439 439 488 780 829 0 341 390 683 683 878 0 176 137 137 176 137 137 176 176 205 205 205 380 390 0 975 1170 1268 1463 2048 634 634 634 634 634 634 634 634
EA EA EA EA EA EA EA EA EA EA EA EA EA
400 300 300 300 300 400 400 400 450 450 500 800 850
EA EA EA EA EA
EA EA EA EA EA EA EA EA EA EA EA EA EA
180 140 140 180 140 140 180 180 210 210 210 390 400
EA EA EA EA EA EA EA EA EA EA EA EA EA
1000 1200 1300 1500 2100 650 650 650 650 650 650 650 650
DESCRIPTION OF WORK 4x10 sq.mm 4x16 sq.mm 3 x 25 sq. mm 3.5 x 35 sq. mm Supply, installation, testing and commissioning of Earthing station with copper plate earth electrode with copper plate 600 x 600 x 3mm size and 3m deep filling with alternate layers of charcoal and salt and connection arrangements with earth strips,including watering arrangement.BM chamber with CI cover. Providing pipe earthing station as per drawingNo.ES.95.04.008 including making BM chamber with CI cover and arrangement for watering (For light pole and dispensing pump earthing) Supply and erection of GI/copper wire/strip for loop earthing in pipe/earth/walls with connection etc. complete as required and of following size. 8 SWG GI Wire (4.064mm) 25 x 4 sq.mm GI Strip 25 x 3 sq.mm copper strip Providing earthing station using maintenance free electrode of Ashlok or equivalent make including filling material, electrode and labour complete. upto a depth of 3.5m above 3.5 m to 6m Providing, fixing, testing & commissioning control panel of size as per plan and details using 14 / 16 SWG M.S. Plate with double door including powder coating in machine grey colour including arrangements to fix meters switch gears etc. according to plan and detail incl. locking arrangements & handles etc. complete. Providing and fixing copper busbar of size 25 mm X 5 mm Providing and fixing 3 phase analog type ammeter GEC make or equivalent incl selector switch 0-100Amps 0-200Amps Providing and fixing 3 phase digital type ammeter GEC make or equivalent incl selector switch 0-100Amps 0-200Amps Providing and fixing 3 phase Analog type Voltmeter (0-500V) GEC make or equivalent incl selector switch Providing and fixing 3 phase Digital type Voltmeter (0-500V) GEC make or equivalent incl selector switch Providing and fixing CT for ammeter. for 0-100Amps for 0-200Amps Providing and fixing the following 0-60Hz Frequency meter Set of RYB phase indicating lamps transformer type with slide fuses KWHr meter, 500v 100 amp, three phase (Electronic meter) KWHr meter, 500v 63 amp, three phase (Electronic meter) KWHr meter, 500v 32 amp, three phase (Electronic meter) Internal wiring for control panel in 2.5 Sq.mm & 6 sq.mm Cu. Special wire Fire proof / Flame proof of Polycab or equivalent approved make including FLP lug etc. complete. Providing, fixing, testing & commissioning of power capacitor make Crompton or L&T. Single Phase 1 KVAR Three Phase 1 KVAR Single Phase 2 KVAR Three Phase 2 KVAR Three Phase 5 KVAR Three Phase 6 KVAR
Page 33 of 111
UNIT EA EA EA EA EA
7006590 58
EA
3300
1950
2000
EA EA M3
7006598 62 63 7006599 7006600 64 7006601 01 7006602 02 7006603 65 7006604 66 67 7006605 7006606 68 7006607 7006608 7006609 7006610 7006611 7006612 69 70 7006613 7006614 7006615 7006616 7007742 01 02 03 04 05 06 01 02 01 02 03 04 05 01 02
RM
877.2 #N/A 1053.6 1111.2 #N/A 2047.2 2808 1053.6 2574 #N/A 643.2 702 #N/A 1404 561.6 3744 3627.6 3510 2106 #N/A #N/A 760.8 #N/A 936 3042 #N/A
731 0 878 926 0 1706 2340 878 2145 0 536 585 0 1170 468 3120 3023 2925 1755 0 268 634 439 780 2535 2925
750
EA EA
900 950
EA EA EA EA
EA EA EA SET EA EA EA EA
EA EA EA EA
DESCRIPTION OF WORK Three Phase 10 KVAR Liasion work for permission from local electric supply authorities for increasing of electric supply Load Load upto 45KW. Load from 45 KW upto 90 KW. Liasion work for submitting test report for complete electrical work & getting the same approved from the concerned authority and getting the approval for electrical power connection. Carrying out earth resistance (meggar) test of all electrical installations/earthing installations in allocation Providing fixing testing commissioning switch fuse unit with HRC FUSES including connections complete. (L & T make) 100A TPN switch fuse unit 250A TPN switch fuse unit Providing, fixing, testing, commissioning TPN MCCB of L & T make or equivalent including connection complete. 100A TPN MCCB 200A, TPN MCCB 250A TPN MCCB Providing fixing testing commissioning main switch fuse unit with with respective FUSES including connections complete. Stanley make or equivalent 32A TPN SFU 64A TPN SFU 100A TPN SFU 250A TPN SFU Providing and fixing testing, commissioning change over switch. 63 Amp for provision in electric panel 100 AMP for provision in electric panel 250 AMP for provision in electric panel Providing and fixing RCCB/ELCB with 100MA tripping current capacity with its MS BOX including connection and testing etc. complete.(INDO KOPP) 63A TPN ELCB 40A TPN ELCB 40A TWO POLE ELCB 32A TPN ELCB 32A TWO POLE ELCB Providing and fixing miniature circuit breaker [3 phase] of approved quality and make confirming to IS 8828 for following ratings :(INDO KOPP, HAGER, MDS) 5 AMP 15 AMP 32 AMP 40 AMP 64 AMP 100 AMP (Isolator Switch) Providing and fixing miniature circuit breaker [single phase/double pole] of approved quality and make confirming to IS 8828 for following ratings :(INDO KOPP, HAGER, MDS) 5 AMP 15 AMP 32 AMP 40 AMP 64 AMP Providing and fixing miniature circuit breaker [single phase single pole] of approved quality and make confirming to IS 8828 for following ratings :(INDO KOPP, HAGER, MDS) 5 AMP 15 AMP
Page 34 of 111
UNIT EA
EA EA EA
7006620 73 74 7006621 7006622 75 7006623 7006624 7006625 76 7006626 7006627 7006628 7006629 77 7006630 7006631 7006632 78 7006633 7006634 7006635 7006636 7006637 79 7006638 7006639 7006640 7006641 7006642 7006643 80 7006644 7006645 7006646 7006647 7006648 81 7006649 7006650 01 02 01 02 03 04 05 01 02 03 04 05 06 01 02 03 04 05 01 02 03 01 02 03 04 01 02 03 01 02
EA
117.6 #N/A
98 0 4095 6825 0 3315 6533 10725 0 1268 1950 3413 6825 0 2925 5363 9750 0 2194 1950 1706 1950 1706 0 488 488 488 731 731 780 0 414 414 414 488 536 0 146 146
100
EA EA
4914 8190 #N/A 3978 7839.6 12870 #N/A 1521.6 2340 4095.6 8190 #N/A 3510 6435.6 11700 #N/A 2632.8 2340 2047.2 2340 2047.2 #N/A 585.6 585.6 585.6 877.2 877.2 936 #N/A 496.8 496.8 496.8 585.6 643.2 #N/A 175.2 175.2
4200 7000
EA EA EA
EA EA EA EA EA EA EA
EA EA EA EA EA
EA EA EA EA EA EA
EA EA EA EA EA
EA EA
150 150
SERVICE NO 7006651 7006652 7006653 82 7006654 7006655 7006656 83 7006657 7006658 7006659 84 7006660 7006661 7006662 7006663 7006664 7006665 85 01 02 03 04 05 06 01 02 03 01 02 03 03 04 05
DESCRIPTION OF WORK 32 AMP 40 AMP 64 AMP Providing, fixing, testing, commissioning main switch including connection complete. 4 pole,200A Havells/ Siemens make.ICTP 4 pole,100A Havells/ Siemens make. ICTP 4 pole,63A Havells/ Siemens make. ICTP Providing, fixing, testing, commissioning change over mainswitch including connection complete. 200A, 4 pole Havells or Siemens 100A 4 pole Havells or Siemens 63A 4 pole Havells or Siemens Supplying and fixing metal box for MCB of MDS or equivalent make For 2 switches For 4 switches For 8 switches For 12 switches For 16 switches For 24 switches. For 32 switches. Supply, installation, testing and commissioning of prewired wall/ceiling/false ceiling mounted type HPF fluorescent light fixtures including providing and fixing tubes,chokes, starters, capacitors, earthing connections and mounting arrangements etc. comp 1 x 40W similar to Philips light fixture No. TMC 18/140 1 x 19W similar to Philips light fixture No. TBS/118 Slimlight for Toilets. 2 x 40W similar to Philips light fixture No.TBS 50/236 HPF Mirror optics (False Celing) 36/236 2 x 40W similar to Philips light fixture No. TPW 11/236 1x40 w Decorative box type tube light fitting similar to Philips cat NoTMS 21/136 SRX 51/150W HPSV FITTING SONT 150W LAMP 2 x 40W similar to Philips light fixture No. TBS 305/418 1 x 40W TBS 50/136 HPF (Mirror Optics) for false ceiling. 1x40 w Patty type tube light fitting of Philips or equivalent make 1x20 w Patty type tube light fitting similar to Philips cat No TMC 15/120 DN 622 Philips make fixture and luminare PLET 20W/85/86 2 x 40 watt Philips make TCS 781/236 HPF visa 2x11 w CFL 600 mm long light fitting complete with electronic choke Acrylic cover, End caps etc. 20 w CFL Light fitting recess mounting type with electronic choke 2x11 w CFL Mirror Optics Type fitting Similar to Philips Cat No FBS 285 /211 PROVIDING AND FIXING P/F 2x36 watt mirror optical CFL fixture of Bajaj/Cropmton/Philips or approved make ( BMMR-236) P/F 3x36 watt mirror optical CFL fixture of Bajaj/Cropmton/Philips or approved make ( BMMR-336) P/F 600mm x 20 watts fluorescent tube light [Rod] in dispensing pump P/F 1200mm x 40w fluorescent tube light [rod] on building P/F 1200 mm x 40 w weather proof street lighting 'lighting fixture single tube type with acrylic cover incl.tubes P/F 1200 mm x 40 w weather proof street lighting fixtures double tube type with acrylic cover incl. tubes. Supplying and fixing following either of Philips, Crompton or GCC made including all necessary arrangement to fix the same. Philips MVC 52/150 metal halide fixture including 150Wluminaire and control gear.
Page 35 of 111
UNIT EA EA EA EA EA EA
New SOR 175.2 262.8 262.8 #N/A 6435.6 4095.6 2574 #N/A #N/A #N/A #N/A #N/A #N/A 702 772.8 1257.6 1696.8 2340 3510 #N/A
146 219 219 0 5363 3413 2145 0 6338 4875 3120 0 0 585 644 1048 1414 1950 2925 0
EA EA EA EA EA EA EA EA EA EA
7006666 7006667 7006668 7006669 7006670 7006671 7006672 7006673 7006674 7006675 7006676 7006677 7006678 7006679 7006680 7006681 86 7006682 7006683 7006684 7006685 7006686 7006687 87 7006688
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 01 02 03 04 05 06
EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA
374.4 374.4 643.2 2925.6 2925.6 673.2 5148 3744 1638 386.4 386.4 819.6 2457.6 2457.6 1638 1638 #N/A 3978 4329.6 75.6 81.6 1462.8 1989.6 #N/A
312 312 536 2438 2438 561 4290 3120 1365 322 322 683 2048 2048 1365 1365 0 3315 3608 63 68 1219 1658 0 4778
320 320 550 2500 2500 575 4400 3200 1400 330 330 700 2100 2100 1400 1400 3400 3700 65 70 1250 1700
01
EA
5733.6
4900
DESCRIPTION OF WORK Philips HRX 51/250 metal halide fixture including 250Wluminaire and control gear. Phillips MVC 52/150 metal halide ballast of 150w Phillips HRX 51/250 metal halide ballast of 250w S/F 25W/40W/60W/100W bulbs S/Fixing following fittings either of Philips,Crompton or GCE made incl. all necessary arrangement to fix the same. Supply, installation and commissioning of exhaust fans suitable for use of 220/240V 50Hz single phase with frame gravity drop louvers clamps etc. complete as required 300sweeps size. Supply, installation and commissioning of exhaust fans suitable for use of 220/240V 50Hz single phase with frame gravity drop louvers clamps etc. complete as required 450sweeps size. Supply, installation, testing and commissioning of 1400mmsweep 220V, 50Hz AC ceiling fan including providing fan hook suspension rod 300mm long connections, earthing electronic dimmer type regulators etc. complete as required. Fixing supplied light fixtures for canopy false ceiling including suspending the fixture from the top canopy structure with supplied control gear including making electrical connections etc complete as directed. Fixing the supplied metal halide/SV street luminaires on yard lighting Supplying fixing following switches including making electrical cable connecting etc. complete 5 AMPS tumbler/toggle switch (Anchor make) 15 AMPS HDDP switch (Anchor make) 15 AMPS (250V) ICDP switch (Stanley make) 15 AMPS (500V)ICDP switch (Stanley make) 16 AMPS ICTP switch (Stanley make) 32 AMPS ICTP switch (Stanley make) 64 AMPS ICTP switch (Stanley make) 63 AMPS TPN fuse switch unit with HRC fuses 125 AMPS TPN fuse switch unit with HRC fuses Supplying and fixing CFL lamp 9W with adaptor for Dispensing Unit Supplying and fixing Motor control ON/OFF Relay 10 Amps Supplying and fixing Contactor for 1.5 HP Redjacket STP 40 Amps 4 pole Cutler Hammer make Supply / fix 'Presto or equivalent make PVC switch board incl. Internal wiring :-of sizes 8 x 10 10 x 12 Rewiring the switchboard with 3/20 PVC installed copperwire, removing and refixing switches etc. complete." for size 900 X 600 mm for size 450 X 600 mm Disconnecting and dismantling switches along with switchboard/switch box at Ros Supply & fixing 0.5 kva CVR/CVT of standard make like Su-kam/Bhurji etc for MPD. Supply & fixing 1.0 kva CVR/CVT of standard make like Su-kam/Bhurji or equivalent etc for MPD. Providing, installing & commissioning single phase voltage stabilizer ( range 160 v to 260 v ) incl over load trip relay of approved make (Logicstat/Blue bird / Bhurji/ Kiranotics etc) etc., complete. 01 02 03 99 2 kva 5 kva 7.5 kva Providing, installing & commissioning oil/Air cooled unbalanced type 3 phase voltage stabilizer ( range 160 v to 260 v ) incl over load trip relay of approved make (Logicstat/Blue bird / Bhurji/ Kiranotics etc) incl cost of oil etc complete. 20kva
Page 36 of 111
UNIT EA EA EA EA
EA
1350
7006694
02
EA
1813.2
1511
1550
7006695
03
EA
1650
1365
1400
7006696
04
EA
608.4
507
520
7006697 89 7006698 7006699 7006700 7006701 7006702 7006703 7006704 7006705 7006706 8000560 90 8000561 91 8000562 92 93 7006709 7006710 94
05
EA
321.6 #N/A 25.2 117.6 632.4 632.4 1345.2 1755.6 2106 2340 6318 526.8 526.8 3042 #N/A 936 1053.6 #N/A 760.8 585.6 262.8 #N/A #N/A #N/A
268 0 21 98 527 527 1121 1463 1755 1950 5265 439 439 2535 0 780 878 0 634 488 219 5363 7020 0
275
01 02 03 04 05 06 07 08 09
EA EA EA EA EA EA EA EA EA EA EA EA
22 100 540 540 1150 1500 1800 2000 5400 450 450 2600
01 02
EA EA
800 900
EA EA EA EA EA
EA EA EA
7006718
01
EA
#N/A
43875
45000
SERVICE NO 7006719 7006720 03 7006721 04 New 100 9002448 101 7006725 102
DESCRIPTION OF WORK 30 kva 40 kva 60 kva Installation of supplied servostabilizer incld. Internal wiring Installation of supplied UPS incld. Internal wiring Shifting of electrical panel incl. Disconnecting all cables, glands etc. & making re-connections at shifted place. Jobs also incl. Dismantling / re-fixing of panel as reqd. incl. Cost of material & labour etc. complete. Supply of material and wiring for light /fan point with 3/20 copper conductor, PVC insulated 650 V grade ISI wires in heavy duty ISI 20 mm PVC conduit laid in existing tray / on wall / in ceilings / floor complete with required plate swithches / ceiling rose. One light point controlled by one switch and wiring as above. Two light points controlled by one switch and wiring as above. Three light points controlled by one switch and wiring as above. Extra over and above item No. 1c incl. supplying material and wiring for each additional light point (Over three light points) controlled by one switch point. Supply and fixing of modular switch frame and accessories as per details Roma/Crabtee/Sapphire make or equivalent including flush metal boxes / surface mounting boxes plate etc complete as per manufacturers specification and Engnieer in charge. 1 way modular frame 2 way modular frame 3 way modular frame 4 way modular frame 6 way modular frame 8 way modular frame 12 way modular frame 18 way modular frame 24 way modular frame S/F Modular Switch- Roma / crabtree or equivalent a) 6 Amp Modular Switch b) 16 Amp Modular Switch c) False plate for Modular Switch d) 5Amp 5pin plug socket e) 16 Amp 5pin plug socket Providing concealed wiring for light/fan points with 3/20PVC insulated copper conductor wire of approved make and quality in 20mm PVC heavy duty conduit pipe with all fittings like holders switches, wooden blocks, boards etc." Providing concealed wiring for for plug point incl. socket with 3/20PVC insulated copper conductor wire of approved make and quality in 20mm PVC heavy duty conduit pipe with all fittings like holders switches, wooden blocks, boards etc." Providing surface wiring for light/fan points with 3/20PVC insulated copper conductor wire of approved make and quality with all fittings like holders, switches, rosers,boards, etc. complete." 20mm PVC flat casing with PVC round 20 mm pipe Providing surface wiring with 3/20 PVC insulated copper conductor wire of approved make and quality with all fittings like holders, switches, rosers, boards, etc.complete." Providing surface wiring with 3/20 PVC insulated copper conductor wire of approved make and quality with all fittings like holders, switches, rosers, boards, etc.complete." for plug point incl. socket Providing and fixing 20A plug point with 6 Sq.mm single core copper conductor PVC insulated, 650V grade wires in PVC conduit pipe laid in existing tray / on wall with SP&N MCB, SP&N 20A metal clad socket and earthing the third pin with 14 SWG CU. Earth wire complete.
UNIT EA EA EA EA EA EA
7006726 103 01
EA
409.2
341
350
02 03 04 05
EA EA EA EA
7006731 7006732 7006733 7006734 7006735 7006736 7006737 7006738 7006739 105 7006740 7006741 7006742 7006743 7006744 7006745 106
01 02 03 04 05 06 07 08 09 01 02 03 04 05
EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA
187.2 187.2 234 246 409.2 409.2 468 526.8 643.2 #N/A 117.6 152.4 24 152.4 234 439.2
156 156 195 205 341 341 390 439 536 98 127 20 127 195 366
160 160 200 210 350 350 400 450 550 100 130 20 130 200 375
7006746 107
EA
222
185
190
108
#N/A
01 02
EA EA
341 293
350 300
EA
185
190
7006750 111
EA
907.2
756
775
Page 37 of 111
SERVICE NO 112
DESCRIPTION OF WORK Supply of material and wiring for power outlets with PVC insulated single core copper conductor wire in minimum 25mm dia PVC conduit with 14 SWG earthwire accessories like bends, tees junction box chunk nuts earthing connections including concealing in RCC/wall 2 x 1.5 sq.mm copper conductor wire 2 x 2.5 sq.mm copper conductor wire 3 x 2.5 sq.mm copper conductor wire 3 x 6 sq.mm copper conductor wire 4 x 10 sq.mm copper conductor wire Providing and fixing 5A plug point and 5A three pin plate socket outlet with 5A switch and earthing the third pin with CU earth wire connections, etc. complete and wiring as above. Providing and fixing 15A plug point with 4 Sq.mm single core copper conductor , PVC insulated 650 V grade wires in heavy duty ISI 20 mm PVC conduit pipe laid in existing tray / on walls with 5A / 15A socket of approved make like Anchor etc., 15A plate switch complete. Providing and fixing 15A plug point with 4 Sq.mm single core copper conductor , PVC insulated 650 V grade wires in heavy duty ISI 20 mm PVC conduit pipe laid in existing tray / on walls with industrial type plug point of approved make. Supply, laying, connecting, testing and commissioning following ISI unarmoured PVC insulated cables for circuit wiring incl. cost of 25mm dia heavy duty ISI PVC conduit with 14 SWG earthwire accessories like bends, tees junction box chunk nuts earthing con 2 x 1.5 sq.mm copper conductor wire 2 x 2.5 sq.mm copper conductor wire 3 x 2.5 sq.mm copper conductor wire 3 x 6 sq.mm copper conductor wire 4 x 10 sq.mm copper conductor wire Supplying and laying ISI heavy duty 6 kg/cm2 PVC conduit / pipe with accessories and hardware complete as required. in wall / floors, ceilings, false ceilings etc (Prakash / Triputi / Kishan etc.) PVC pipe 25 mm dia PVC pipe 50 mm dia PVC pipe 75 mm dia PVC pipe 100 mm dia PVC pipe 150 mm dia P & F of following fitting of Anchor or approved make a) 5 AMP Piano type b) 16 AMP Piano type c) 5 AMP 3 pin plug socket d) 16 AMP 5 pin plug socket e) Electronic Fan regulator f) Telephone Socket Supply,delivery & fixing of the following: Insulating rubber matting 6mm thk 11KV grade size 1mx2m conforming to IS -5424/1969 to cover the front of main LT panel. Fire Extinguishers of 10 kg capacity complete with nozzle, hook and fixing arrangement. DCP Type(Mini Max make) Danger Plate 415 V/Caution Board, 200x150mm) Shock Treatment Chart First Aid Box (Std. Size) excluding Medicines Supply, delivery and fixing of fire buckets (set of four buckets) of 9Ltr capacity complete with fixing brackets and initial charge for buckets along with MS supporting stand complete with primer coating and enamel paint etc. as required. Providing and wiring for telephone connection using wires of following specification in 20mm PVC conduit pipe including sockets complete 2 pair wire 5 pair wire S/fixing of HRC fuses
Page 38 of 111
UNIT
OLD SOR
01 02 03 04 05
M M M M M EA EA
7006758 115
EA
555.6
463
475
116
#N/A
01 02 03 04 05
RM RM RM RM RM
29 59 88 176 410
30 60 90 180 420
7006764 7006765 7006766 7006767 7006768 118 7006769 7006770 7006771 7006772 7006773 NEW 119 7006774 7006775
01 02 03 04 05 01 02 03 04 05 06 01 02
RM RM RM RM RM EA EA EA EA EA EA EA EA EA EA EA EA
87.6 175.2 262.8 292.8 351.6 #N/A 24 87.6 46.8 93.6 175.2 1540 #N/A 1170 2691.6 199.2 262.8 #N/A 1521.6
73 146 219 244 293 20 73 39 78 146 63 975 2243 166 219 268 1268
75 150 225 250 300 20 75 40 80 150 65 1000 2300 170 225 275 1300
SERVICE NO 7006782 7006783 7006784 7006785 123 7006788 7006789 7006790 7006791 8000563 8000564 8000565 7006403 8000566 NEW 124 125 126 127 128 129 130 01 02 03 01 02 03 04
DESCRIPTION OF WORK 32 Amp 63 Amp 100 Amp 200 Amp S/ fxing of following items for electronic register assy. Of D/pump as applicable. 10AMP fuse unit 6 AMP fuse unit 1.5 AMP fuse unit. S / fixing of 4 copper bus bar including all necessary insulators etc. complete S / fixing of copper bus bar including all necessary insulators etc. complete Labour charges for Fixing supplied tubelight Labour charges for Fixing supplied starter for 36W/40W Tubelight Labour charges for Fixing supplied choke for 36W/40W Tubelight Supply & fixing side holder for Tubelight Supply & fixing starter base S/ F of recess mounting (CAT-2) luminaire with 3D & OLC optics designed for metal / Gypsum or similar falsce ceiling mounting system with concealed or exposed T section with 4 X TL5, 14 W lamp (colour 82). Philips make TBS 669/414 HF:MDGNC S/F of special, low glare recessed down lightes suitable for use with metal halide lamp with glass cover inclusive of gear box and 70W metal halide colour 82 lamp of Philips make MB 175 : glass cover. S/L wiring for power outlets (for overhead EB service) with PVC insulated single core copper conductor wire in min 25mm dia PVC conduit with 14 SWG earth wire and accessories like bends, tees junction box chunk nuts earthin connection etc.The rate is for individual run of the wire. Supply, fixing and commissioning of approved make of ENERGY METERS, as approved by Engg incharge - SINGLE PHASE - For Sub metering Supply, fixing and commissioning of approved make of ENERGY METERS, as approved by Engg incharge - THREE PHASE - For Sub metering Supply and laying of cat6 network cable of approved make Supply laying and connecting 8 SWG bare copper wire for Pumps earthing Supply and fixing of 16A closed type 12 way bakelite type terminal connectors of approved make Supply and fixing of 63A 3 - way & off selector switch for phase change system Supply and fixing of 100A Bakelite Knife type fuse bases Transportation of canopy / yard light fittings with lamp to RO Transportation of UPS with all accessories to RO Supplying and fitting following fitting either of Philips,Crompton or GEC make including all necessary arrangement to fix the same in Glow facia 1200mm x 36W fluorescent tube light (rod) HF/Low Losschoke for 40/36W tube Light Starter for tube light Tube holder for tube light Supply fixing and wiring of Capacitor for STP of approved make Supply & laying of following size of PVC casing and caping 20mm 25mm 32mm MECHANICAL - UNDERGROUND TANKS/PIPELINES Exhuming underground tank from earth pit with or without HD tank fittings from the under ground earth / masonry pit using chain pully block / crane, incl. disconnecting suction, vent and fill pipeline connections, opening manhole cover, degasing the tank, back filling the pit with excavated as well as with imported earth well consolidation of the filled up pit and stacking exhumed tank with fittings anywhere within the site premises as directed. 4.5/6.8 KL
Page 39 of 111
UNIT EA EA EA EA EA EA EA EA KG EA EA EA EA EA EA
New SOR 70.8 87.6 128.4 234 #N/A 70.8 46.8 28.8 #N/A 502.8 34.8 12 70.8 24 24 1540
NEW 131
EA
1540
2438
2500
NEW 132
1540
341
350
NEW 133 NEW 134 NEW 135 NEW 136 NEW 137 9004203 NEW NEW NEW 138 139 140 141
EA EA RM RM EA EA EA EA EA
1540 1540 1540 1540 1540 #N/A 1540 1540 1540 #N/A 1540 1540 1540 1540 1540 #N/A 1540 1540 1540 #N/A #N/A
EA EA EA EA EA RM RM RM
7007492
01
EA
4560
3800
3500
DESCRIPTION OF WORK 9/10 KL 15 KL 20 KL 45 KL 70 KL Exhuming underground tank from masonry pit with tank fittings from the under ground earth / masonry pit using chain pully block / crane, incl. disconnecting suction,vent and fill pipeline connections, opening manhole cover,degasing the tank, back filling the pit with excavated as well as with imported earth well consolidation of the filled up pit and stacking exhumed tank with fittings anywhere within the site premises as directed. 4.5/6.8 KL 9/10 KL 15 KL 20 KL 45 KL 70 KL Exhuming underground tank from masonry pit with RCC beam/slab on top by lifting/breaking slab/beam, with tank fittings from the under ground earth /masonry pit using chain pully block / crane, incl. disconnecting suction, vent and fill pipeline connections,opening manhole cover, degasing the tank, back filling the pit with excavated as well as with imported earth well consolidation of the filled up pit and stacking exhumed tank with fittings anywhere within the site premises as directed. 4.5/6.8 KL 9/10 KL 15 KL 20 KL 45 KL 70 KL Removing dead stock in containers from the U/G tank and cleaning it internally, thoroughly incl. disconnecting suction and fill line connections, removing manhole cover, removing and disposing dead stock/sludge as directed,degasing the tank and connecting suction and fill lines,fixing manhole covers with supplying and fixing 3mm thick compressed graphite asbestos gasket, fixing nuts, bolts etc. complete. 4.5/6.8 KL 9/10 KL 15 KL 20 KL 45 KL 70 KL 100 KL Removing dead stock in containers from the U/G MS tank and cleaning it internally, thoroughly incl. disconnecting suction and fill line connections, removing manhole cover,removing and disposing dead stock/sludge as directed,degasing the tank and connecting suction and fill lines,fixing manhole covers with supplying and fixing 3mm thick compressed graphite asbestos gasket, fixing nuts, bolts etc. complete with all safety/breathing equipments 4.5/6.8 KL 9/10 KL 15 KL 20 KL 45 KL 70 KL 100 KL
UNIT EA EA EA EA EA
01 02 03 04 05 06
EA EA EA EA EA EA
01 02 03 04 05 06
EA EA EA EA EA EA
01 02 03 04 05 06 07
EA EA EA EA EA EA EA
01 02 03 04 05 06 07
EA EA EA EA EA EA EA
Page 40 of 111
SERVICE NO 6
DESCRIPTION OF WORK Pressure testing the tank with water to a pressure of 0.36Kg/ sq.cm incl. supply of pure water,.fixing 50mm dia pipe3.67m high and emptying the same after testing and cleaning the internal surface of the tank. 9/10 KL 15 KL 20 KL 45 KL 70 KL 100 KL Supply of water in vehicle mounted water tanks as required for the site, as directed by the Engg incharge Cleaning and scraping only the external surface of the tank with wire brushes and emery paper and removing all mill scales, rust, dirt etc. complete. 9/10 KL 15 KL 20 KL 45 KL 70 KL 100 KL Doping the external surface of tank , holding down arrangements, bolts, buckles etc. with two coats of Bituminous primer and applying two coats of Plastic Asphalt to achieve overall thickness of 3mm (Payment will be on the basis of the surface area of tank only and no separate payment for fittings will be made.) Lowering the tank into the pit using chain pulley block/crane and positioning the tank in the pit incl. tightening the holding down bolts. Any damage to the tank and/or doping at the time of lowering should be made good by the contractor. 9/10 KL 15 KL 20 KL 45 KL 70 KL 100 KL Supplying and welding MS doubler plate 200 X 200 X 6mm onto the old tank (Rate includes supplying all materials and consumables). Supplying 3 mm thick compressed graphite asbestos gasket for manhole cover. Removing manhole cover after disconnecting suction, fill and vent pipes. Removing heavy duty cover and frame of existing tank manhole sump, removing and disposing debris, refixing the frame with new CC1:2:4 bedding 150mm thick over sump wall and placing sump cover complete. Removing water from U/G tank using semi-rotary hand pump without loss of product. Rate includes hire/transportation charges of pump and disconnecting and refixing the pipeline as necessary Upto 500 ltrs. of water per tank Above 500 ltrs. of water per tank Supplying and fitting 50mm vent hood for U/G tank vent pipe comprising of 2 nos. 50mm elbows, 1 no. 50mm nipple with 2layers of brass mesh of 11 mesh/linear cm as per our standards. Supplying 16mm diameter 50mm length of approved quality and make (GKW) bolts, nuts and washer complete. Supplying and fixing 2 layers approved quality wire mesh Making the additional point in the existing manhole cover of tank as per our std. practice incl. P & F required size of flanges, inside suction pipe incl. Opening & refitting the manhole cover. 01 50 dia
Page 41 of 111
UNIT
OLD SOR
7007525 7007526 7007527 7007528 7007529 7007530 NEW 7 7007531 7007532 7007533 7007534 7007535 7007536 7007537 8
01 02 03 04 05 06
EA EA EA EA EA EA Per KL
01 02 03 04 05 06
EA EA EA EA EA EA M2
#N/A
7007538 7007539 7007540 7007541 7007542 7007543 7007544 10 7007546 7007547 7007548 7007549 11 12 13 14
01 02 03 04 05 06
EA EA EA EA EA EA EA EA EA EA EA
2400 3000 3600 5130 6270 7980 1596 1254 1000 900 855
2100 2600 3100 4600 5600 7100 1400 1050 850 625 725
2000 2500 3000 4500 5500 7000 1400 1000 850 600 700
15
#N/A
EA EA EA
7007553 17 7007554 18 19
EA M2
92 150 #N/A
80 125
80 120
7007555
EA
1653
1400
1400
DESCRIPTION OF WORK 75 dia 100 dia Making modifications in u/g tank manhole to accommodate submersible pump incl. Cost of material & labour etc.complete. Disconnecting all pipelines, removing manhole cover of U/G tank, transporting to local workshop and making necessary arrangements for addl. suction line, bringing it back to site and refixing the manhole incl. resorting all pipelines as earlier complete. Transporting the 9/10KL tank with all accessories incl. loading, unloading ( Octroi, taxes etc. if any) payable at actual on production of document. Distance 1 to 50 KM Beyond 50 KM Transporting the 15KL tank with all accessories including loading, unloading ( Octroi, taxes etc. if any) payable at actual on production of document. Distance 1 to 50 KM Beyond 50 KM Transporting the 20KL tank with all accessories including loading, unloading ( Octroi, taxes etc. if any) payable at actual on production of document Distance 1 to 50 KM Beyond 50 KM Transporting the 45KL tank with all accessories including loading, unloading ( Octroi, taxes etc. if any) payable at actual on production of document Distance 1 to 50 KM Beyond 50 KM Supplying, fabricating, fixing MS plate cover with angle iron frame , two nos. chop down handle made out of 12mm dia MS rod and stiffeners incl. painting with two coats of approved make, quality, Red Oxide primer and black enamel paint as directed f Flange packing for the U/G tanks using 3mm thick asbestos graphite packing. Supplying and fixing locking arrangement as per the company's standard specifications Fill line Dip pipe Supplying and filling water in tank after lowering it into the pit for avoiding floatation and emptying out water from the tank after completion of the job Supplying and fixing 25mm dia and 1.2 meter long MS threaded bolts with nuts & washers incl. providing 100 X100 X 6mm thick MS base plate for HD arrangement Installation of cylindrical underground tank without HD arrangement as per our Drg. in Earth pit , after excavation in all kinds of soil, bailing out of water, lowering the tank, levelling and testing the tank hydrostatically with fresh water to a pressure of 0.36kg/ cm2 for 2 hrs. painting with 2 coats of PF4 applying Shalimar tar plastic3 mm thick including cost of paint to exterior surface of the tank, back filling with good quality earth in 150 mm, layers including adequate watering, ramming etc upto top level of the pit . as per std. drawing incl. cleaning of the site, providing 3 mm thick compressed graphite asbestos at manhole cover incl. supply of materials, labour, complete to the satisfaction of Engineer-in-Charge with RCC/masonry kerb wall. 9/10 KL tank as per std drg no E.1S.01.019 15 KL tank as per std drg no RE.DRG.401 20 KL tank as per std drg no RE.DRG.402 45 KL tank as per std drg no E.1S.01.019 70 KL tank as per std drg
UNIT EA EA EA EA
#N/A EA KM 3705 17 #N/A 3900 17 #N/A 4500 17 #N/A 7000 23 68 3200 15 2700 15
EA KM
3500 15
2700 15
EA KM
4000 15
3200 15
EA KM KG
6000 15 56
3500 15 55
EA EA EA EA EA EA
01 02 03 04 05
EA EA EA EA EA
Page 42 of 111
SERVICE NO 33
DESCRIPTION OF WORK Installation of cylindrical underground tank with HD arrangement as per our Std. Drg. in earth pit , after excavation in all kinds of soil, bailing out of water,lowering the tank, levelling and testing the tank hydrostatically with fresh water to a pressure of 0.36kg/cm2 for 2 hrs. painting with 2 coats of PF4 applying Shalimar tar plastic 3 mm thick including cost of paint to exterior surface of the tank, back filling with good quality earth of 150 mm, layers including adequate watering, ramming etc upto the top level of pit as per std. drawing incl. cleaning of the site, providing 3 mm thick compressed graphite asbestos at manhole cover incl.supply of materials, labour, complete to the satisfaction of Engineer-inCharge with RCC/masonry kerb wall. 01 02 03 04 05 34 9/10 KL tank as per std drg no E.1S.01.019 15 KL tank as per std drg no RE.DRG.401 20 KL tank as per std drg no RE.DRG.402 45 KL tank as per std drg no E&P.RET.T1.03 70 KL tank Installation of cylindrical underground tank without HD arrangement as per our std. drg. no. in masonry pit,after excavation in all kinds of soil, bailing out of water,lowering the tank, levelling and testing the tank hydrostatically with fresh water to a pressure of 0.36kg/cm2 for 2 hrs. painting with 2 coats of PF4 applying Shalimar tar plastic 3 mm thick including cost of paint to exterior surface of the tank, back filling with good quality earth of 150 mm, layers including adequate watering, ramming etc upto the top level of pit. as per std. drawing incl. cleaning of the site, providing 3 mm thick compressed graphite asbestos at manhole cover incl.supply of materials, labour, complete to the satisfaction of Engineer-in-Charge with RCC/masonry kerb wall. 9/10 KL tank as per std drg no E.1S.01.019 15 KL tank as per std drg no RE.DRG.401 20 KL tank as per std drg no RE.DRG.402 45 KL tank as per std drg no E&P.RET.T1.03 70 KL tank Installation of cylindrical underground tank with HD arrangement as per our std. drg. in masonry pit,a fter excavation in all kinds of soil, bailing out of water,lowering the tank, levelling and testing the tank hydrostatically with fresh water to a pressure of 0.36kg/cm2 for 2 hrs. painting with 2 coats of PF4 applying Shalimar tar plastic 3 mm thick including cost of paint to exterior surfce of the tank, back filling with good quality earth of 150 mm, layers including adequate watering, ramming etc upto the top level of pit. as per std. drawing incl. cleaning of the site, providing 3 mm thick compressed graphite asbestos at manhole cover incl. supply of materials, labour, complete to the satisfaction of Engineer-in-Charge with RCC/masonry kerb wall. 9/10 KL tank as per std drg no E.1S.01.019 15 KL tank as per std drg no RE.DRG.401 20 KL tank as per std drg no RE.DRG.402 45 KL tank as per std drg no E&P.RET.T1.03 70 KL tank Installation of cylindrical underground tank in masonry pit with RCC sleeper beams as per our std. drg., after excavation in all kinds of soil, bailing out of water,lowering the tank, levelling and testing the tank hydrostatically with fresh water to a pressure of 0.36kg/cm2 for 2 hrs. painting with 2 coats of PF4 applying Shalimar tar plastic 3 mm thick including cost of paint to exterior surface of the tank, back filling with good quality earth of 150 mm, layers including adequate watering, ramming etc upto the top level of pit as per std. drawing incl. cleaning of the site, providing 3 mm thick compressed graphite asbestos at manhole cover. incl.supply of materials, labour, complete to the satisfaction of Engineer-in-Charge. 9/10 KL tank as per std drg no E.1S.01.019 15 KL tank as per std drg no RE.DRG.401 20 KL tank as per std drg no RE.DRG.402 45 KL tank as per std drg E&P.RET.T1 70 KL tank
Page 43 of 111
UNIT
OLD SOR
EA EA EA EA EA
01 02 03 04 05
EA EA EA EA EA
01 02 03 04 05
EA EA EA EA EA
01 02 03 04 05
EA EA EA EA EA
SERVICE NO 37
DESCRIPTION OF WORK Installation of cylindrical underground tank in masonry pit with RCC slab as per our std. drg., after excavation in all kinds of soil, bailing out of water, lowering the tank,levelling and testing the tank hydrostatically with freshwater to a pressure of 0.36kg/ cm2 for 2 hrs. painting with2 coats of PF4 applying Shalimar tar plastic 3 mm thick including cost of paint to exterior surface of the tank, back filling with good quality earth of 150 mm, layers including adequate watering, ramming etc upto the top level of pit as per std. drawing incl. cleaning of the site, providing 3 mm thick compressed graphite asbestos at manhole cover. incl. supply of materials,labour, complete to the satisfaction of Engineerin-Charge. 9/10 KL tank as per std drg no E.1S.01.019 15 KL tank as per std drg no RE.DRG.401 20 KL tank as per std drg no RE.DRG.402 45 KL tank as per std drg E&P.RET.T1 70 KL tank Removing RCC sleeper beams of U/G tanks and resetting incl. restoration of edges Disconnecting pipeline connections, replacing available angle Check Valve and reconnecting the pipeline gate valves. Doping of U/G pipeline with 3 coats of Shalimar tank mastic bitumen paint as per specifications and as directed 40mm dia 50mm dia 80mm dia Providing / constructing BM chamber for tank Including plastering in c.m.1:4 and pcc 1:3:6 around the M/H bottom at complete. manhole size 1 m x 1 m x 0.9 m ht. 0.6 m x 0.6 m x 0.9 m for additional suction / Dip M/H Alteration of internal fill pipe of new tanks by cutting /welding to make straight Breaking the CC above tank M/H to access the M/H bolts/check valve and restoring the CC to make water tight. Cleaning existing vent line incl. Disconnecting near tank M/H and removal of 'T' from vertical line , flushing the line with water to remove clogging and reconnecting the same." DISPENSING PUMPS Disconnecting electrical, earthing connections and suction line, dismantling foundation bolts, removing pumps from the pedestal and shifting the pump within the outlets as directed Mono Pump DUO Pump 1 product 2 hose 2 product 4 hose 3 product 6 hose 4 product 8 hose Submersible pump Making necessary alteration to the pump pedestal to accommodate new pump Installing new pump on pedestal incl. providing and fixing foundation bolts in CC 1:1.5:3 and connecting suction,electrical, earthing connections. Mono Pump DUO Pump 1 product 2 hose 2 product 4 hose 3 product 6 hose 4 product 8 hose Installing submersible pump on the manhole cover incl. Making necessary alterations to the manhole cover to receive the pump and connecting pressure pipeline ,electrical, earthing connections . Alteration to suction line incl. cost of all materials to suit the new pump Supplying and fixing 4mm thick clear glass for pump of any make including rubber beading
Page 44 of 111
UNIT
OLD SOR
7007601 7007602 7007603 7007604 7007605 7007606 38 7007607 39 40 7007608 7007609 7007610 41
01 02 03 04 05
EA EA EA EA EA M2 EA
01 02 03
RM RM RM
20 25 30
20 25 30
LS LS EA EA EA
1 9002162 9002163 9002164 9002165 9002166 NEW 7007139 7007140 2 3 7007141 7007142 7007143 7007144 7007145 NEW 7007146 4 01 02 03 04 05 07 06
EA EA EA EA EA EA EA EA
#N/A #N/A #N/A #N/A #N/A 1540 1050 300 #N/A 630 780 1860 2220 2520 1540 3120
01 02 03 04 05 06
EA EA EA EA EA EA EA
7006972 5 7007148 6
EA EA
1100 480
300 350
300 300
SERVICE NO 7007149 7007150 7007151 7007152 7 8 9 10 11 7007153 7007154 7007155 12 9002434 9002435 9002436 9002435 13 01 02 03 04 01 02 03
DESCRIPTION OF WORK Supplying and fixing 4mm thick clear glass for pump of any make Supplying and fixing rubber beading for pump glass panel Supplying and fixing Aluminium beading for the pump glass panel Breaking pump island and carting away debris from the site to outside the premises or spreading, levelling within the outlet as directed Packing, loading, transporting and unloading of pump excl. Octroi/ taxes will be paid by production of actual document. Distance 1-50KM Beyond 50KM Charges for loading/unloading of additional pump in the same vehicle Transportation of different items as directed by the engg incharge as required as below ( Including loading/unloading) a) Distance up to 50 KM using smaller vehicle like 407 van, tempo etc b) Beyond 50 km for the smaller vehicle like 407 van , tempo etc ( KM payable will be total KM minus 50 ) c) Distance upto 50 KM using lorries upto 9 Ton capacity d) Beyond 50 km for lorries upto 9 ton capacity ( KM payable will be total KM minus 50 ) Providing and fixing pump guards consisting of MS B class pipe as per the size given below, bent to the required shape and size, as per the drawing and our colour scheme for the pump island ends, incl. cost of paints complete. 100 mm dia MS B Class pipe 75 mm dia MS B Class pipe 50 mm dia MS B Class pipe Providing and fixing pump guards consisting of Stainless Steel pipe as per the size given below, bent to the required shape and size, as per the drawing and our colour scheme for the pump island ends. 100 mm dia Stainless steel pipe 75 mm dia Stainless Steel pipe 50 mm dia Stainless Stell pipe Construction of pump island incl. plastering as per the std. drg. Construction of pump island for MPDs as per std. Drawing. Labour charges for reconditioning Pumping unit inculding reboring Metering unit including reconditioning Labour charges for attending to pump maintenance/breakdowns for electrical/mechanical works. 0-100KM Beyond 100KM Supplying and fixing M.S. flexible hose joint for MPD Supplying and fixing box for fixing the STP relay control box - of size 0.90MX0.75M x 0.20 depth, with CR sheets of 2mm thick, including painting etc complete. Erecting/fixing supplied STP relay control box including cost of labour, hardware and making electrical connections complete. (Excluding the cost of cable), including wiring etc complete. Supply/fixing of solid state relay contact including cost of labour, hardware and making electrical connections complete., 330 V, 25 A Erecting/fixing supplied EDC box for MPD including cost of labour, hardware and making electrical connections complete. (Excluding the cost of cable) PIPELINES AND FITTINGS:
UNIT EA EA EA M3
EA KM EA
1400 10 400
1400 10 400
EA KM EA KM EA
1500 12 2500 15
1200 10 2000 15
01 02 03
EA set set
6500 5000
01 02 03
EA EA EA RM RM EA EA
1540 1540 1540 #N/A 1600 1600 #N/A 780 960 #N/A #N/A #N/A 2160 #N/A #N/A #N/A #N/A #N/A 625 #N/A #N/A #N/A #N/A
1600 1400 1200 1250 1250 700 800 1200 1200 650 800
8000569 19 20 9002439 21
EA EA EA M3
EA
250
22 9002440 23
EA
650
EA
250
Page 45 of 111
SERVICE NO 1
DESCRIPTION OF WORK Supplying and laying U/G and A/G ERW 'C' class pipe 50mmdia for suction/vent/Dip conforming to IS 1239-1979(preferably Tata make) to the required slope and alignment with heavy duty fittings like elbows, tees, bends, unions,couplings, reducers, valves etc .of ISI mark as directed by Site Eng. incl. pressure testing at 3.6 kg/ cm2 or 10Kg/cm2 job also includes excavation of trench, back filling for making the driveway in original after laying pipeline and doping U/G pipeline with two coats of bituminous primer and3mm thick (dry thickness) Shalimar tar plastic or painting A/G pipeline with two coats each of Red Oxide primer and approved quality/shade/make enamel paint after cleaning and scrapping the pipeline to bare metal. This also includes fixing of supplied valves and making necessary connections to pump and/ or tank as the case may be 01 02 03 04 05 06 2 01 02 03 04 05 3 Under ordinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway Above ground
7006852
UNIT
OLD SOR
7006950 7006951 7006952 7006953 7006954 7006955 7006956 7006957 7006958 7006959 7006960
RM RM RM RM RM RM RM RM RM RM RM
Under ordinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway Laying the supplied U/G and A/G ERW 'C' class pipe 50mm dia for suction line/vent/dip conforming to IS 1239-1979 (preferably Tata make) to the required slope and alignment with heavy duty fittings like elbows, tees, bends, unions, couplings,reducers etc . valves etc.of ISI mark as directed by Site Engineer. incl. pressure testing at 3.6 kg / cm2 or 10Kg/cm2 job also includes excavation of trench, back filling for making the driveway in original after laying pipeline and doping U/G pipeline with two coats of bituminous primer and 3mmthick (dry thickness) Shalimar tar plastic or painting A/G pipeline with two coats each of Red Oxide primer and approved quality/shade/make enamel paint after cleaning and scrapping the pipeline to bare metal. This also includes fixing of supplied valves and making necessary connections to pump and/ or tank as the case may be Under ordinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway Above ground Laying the supplied U/G and A/G ERW 'C' class pipe 75mm dia for fill line, conforming to IS 12391979 (preferably Tata make) to the required slope and alignment with heavy duty fittings like elbows, tees, bends, unions, couplings,reducers etc. valves etc .of ISI mark as directed by Site Engineer. incl. pressure testing job also includes excavation of trench, back filling for making the driveway in original after laying pipeline and doping U/G pipeline with two coats of bituminous primer and 3mmthick (dry thickness) Shalimar tar plastic or painting A/G pipeline with two coats each of Red Oxide primer and approved quality/shade/make enamel paint after cleaning and scrapping the pipeline to bare metal. This also includes fixing of supplied valves and making necessary connections to pump and/ or tank as the case may be Under oridinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway
800 850 900 950 1000 790 #N/A 1100 1100 1100 1100 1100 #N/A
625 660 700 750 800 600 800 840 860 900 950
600 650 700 750 800 550 750 800 850 900 950
01 02 03 04 05 06
RM RM RM RM RM RM
01 02 03 04 05
RM RM RM RM RM
Page 46 of 111
SERVICE NO 5
DESCRIPTION OF WORK Supplying, installing, laying, welding & testing M.S. seamless pipeline 50mm dia for suction/vent/Dip confirming to ASTM 106 Gr. B schedule 40 for sunction / fill & ventpipes in proper slopes and level including fittings of heavy duty forged flanges elbows for end fittings etc . testing the pipelines to a pressure of 10 kg/cm2and excavation, backfilling and redoing the surface in original condition complete. Under ordinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway Above ground Supplying, installing, laying, welding & testing M.S.seamless pipeline 75 mm dia fill line confirming to ASTM106 Gr. B schedule 40 for fill pipes in proper slopes and level including fittings of heavy duty forged flanges elbows for end fittings etc . testing the pipeline sand excavation, backfilling and redoing the surface in original condition complete. Under oridinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway Laying, welding & testing the supplied M.S. seamless pipeline 50mm dia confirming to ASTM 106Gr. B schedule 40 for sunction / dip & vent pipes in proper slopes and level including fittings of heavy duty forged flanges, elbows for end fittings etc . testing the pipelines to a pressure of 10kg/cm2and excavation, backfilling and redoing the surface in original condition complete. Under oridinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway Above ground Laying, welding & testing the supplied M.S. seamless pipeline 75mm dia fill line, confirming to ASTM 106 Gr. B schedule 40 for fill pipes in proper slopes and level including fittings of heavy duty forged flanges, elbows for end fittings etc . testing the pipelines to a pressure of 10kg/cm2and excavation, backfilling and redoing the surface in original condition complete. Under oridinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway Supplying, installing, laying, welding & testing ERW C class pipeline 50mm dia for suction/vent/Dip confirming to IS 1239-1979 (preferably Tata make) for sunction / fill &vent pipes in proper slopes and level including fittings of heavy duty forged flanges elbows for end fittings etc . testing the pipelines a pressure of 10 kg/cm2and excavation, backfilling and redoing the surface in original condition complete. Under oridinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway Above ground
UNIT
OLD SOR
01 02 03 04 05 06
RM RM RM RM RM RM
01 02 03 04 05
RM RM RM RM RM
01 02 03 04 05 06
RM RM RM RM RM RM
01 02 03 04 05
RM RM RM RM RM
01 02 03 04 05 06
RM RM RM RM RM RM
Page 47 of 111
SERVICE NO 10
DESCRIPTION OF WORK Supplying, installing, laying, welding & testing ERW 'C' class pipeline 75mm dia fill line confirming to IS1239-1979 (preferably Tata make) for fill pipes in proper slopes and level including fittings of heavy duty forged flanges, elbows for end fittings etc . testing the pipelines to required pressure and excavation, backfilling and redoing the surface in original condition complete. 01 02 03 04 05 11 Under oridinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway Laying, welding & testing the supplied ERW C class pipeline 50mm dia for suction line, confirming to IS 1239-1979(preferably Tata make) for sunction / dip & vent pipes in proper slopes and level including fittings of heavy duty forged flanges, elbows for end fittings etc . testing the pipelines to a pressure of 10kg/sq.M.and excavation, backfilling and redoing the surface in original condition complete. Under oridinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway Above ground Laying, welding & testing the supplied ERW C class pipeline 75 mm dia fill line, confirming to IS 1239-1979(preferably Tata make) for fill pipes in proper slopes and level including fittings of heavy duty forged flanges, elbows for end fittings etc . testing the pipelines to a pressure of 10kg/sq.M.and excavation, backfilling and redoing the surface in original condition complete. Under oridinary soil Under BOE/WBM/Paver driveway Under Bitumen Top Driveway Under CC Driveway Under RCC Driveway Supplying, fixing and painting as per Company's colour scheme 50 mm dip cap assembly and cap of Aluminium with locking arrangement 75 mm fill cap asembly and cap of Aluminium with locking arrangement 50 mm "leader" or equiv.(ISI marked) horizontal check valve with Threaded end 50 mm "leader" or equiv. (ISI marked) horizontal check valve with Flanged end GM Gate valve heavy duty 50 mm dia with Threaded ends "leader" or equiv. (ISI marked) GM Gate valve heavy duty 50 mm dia with Flanged ends "leader" or equiv. (ISI marked) Vertical check valve "leader" or equiv. (ISI marked)50mm dia 50 mm NB Stainless steel ball valve Audco or equivalent Suppling & fixing of 100x75mm reducer of appvd. quality Supplying 50mm aluminium cap for dip cap assembly. Supplying and fixing filter-Cum-water separator for suction line as per our standard incl. cost of all fittings. Providing and constructing pipeline or cable trench incl. excavation in all types of soils, concrete, bitumen, providing CC/BM as per standard drawing Q-119filling the trench with sweet river sand and providing RCC precast slabs on top as per the drawing, curing for 14 days, disposal of excess earth outside the premises to an unobjectionable area complete. for 300 mm inside width for 450 mm inside width for 600 mm inside width for 800 mm inside width
UNIT
OLD SOR
RM RM RM RM RM
01 02 03 04 05 06
RM RM RM RM RM RM
7007011 7007012 7007013 7007014 7007015 13 7007036 7007037 7007038 7007039 7007040 7007041 7007042 7007045 7007046 7007047 7007048 7007049 14
01 02 03 04 05 01 02 03 04 05 06 07 08 09 10 11 12
RM RM RM RM RM EA EA EA EA EA EA EA EA EA EA EA EA
300 325 350 375 400 #N/A 1200 1325 2100 2200 3000 3200 2500 6200 370 380 425 2500 #N/A
300 325 350 375 400 600 620 1750 1750 2600 2600 2000 4000 325 200 300 2200
300 325 350 375 400 1200 750 1750 1750 2600 2600 2000 4000 325 200 300 2200
01 02
RM RM rm rm
1400 1550
Page 48 of 111
SERVICE NO 7007052 15
DESCRIPTION OF WORK Supplying and fixing 12mm square aluminium dip rod of 3m length including marking graduations in mm/cm for under ground tanks and making floating arrangements using dip stoppers and cutting the dip rod suitably complete . Supplying and fixing Aluminium round collar to dip rod and making it floating type excl. extending dip pipe / cutting the dip rod as necessary. Removing RCC slab of pipeline trench excavating sand fill for exposing pipeline to check for leaks, cleaning the pipelines, backfilling the trench with sand and replacing RCC slab after completion of work Disconnecting, dismantling, removing and stacking within the site, existing all dia of pipeline incl. excavation in all types of soils, bitumen and CC driveway and backfilling the same Wire brushing and cleaning the pipe to bare metal and applying 2 coats of Bitumen primer and 3mm thick (dry thickness) of Shalimar tar plastic to : 40mm dia pipe 50mm dia pipe 80mm dia pipe 25mm dia pipe Replacing existing 50mm dia vertical/ horizontal check valve/angle check valve with a new check valve of same size of approved make(Leader/JJ), quality, incl. cost of material and labour Pressure testing suction pipe / fill pipe with water as per std. practice incl. supply of water, emptying the same after hydrotest complete. 3.6 Kg/ sq.cm. 10 Kg/ sq.cm. Disconnecting and removing 40 mm union from pipeline,supplying and fixing packing sheet, refixing the same in proper alignment etc. complete. 40 MM 50MM Disconnecting and removing union from pipeline, supplying and fixing packing sheet, refixing a new union in proper alignment etc. complete. 40mm union 50mm union Repairing, grinding of Check Valve horizontal/vertical/angle so that the seating of the valve is perfect. Cleaning the HSD filter incl. repairing any defect in it and providing gasket sheet Labour charges for fixing supplied items like Check valve/Footvalve/any fittings Constructing BM Sump for filter / valve with internal dimension of 100mm thick CC 1:3:6 for foundation and smooth finish plaster inside, top and bottom and outside portion projecting 150mm A/G inside, top and bottom and outside portion projecting 150mm A/G level complete. Modification of Manhole cover as per our std. including the cost of all materials for installation of 01 02 Submersible pump Additional suction line Installation of supplied flow meter in pipeline (80/100 mm)including of all materials and labour cost.
UNIT EA
1300
7007053 16 7007054 17
EA RM
510 100
400 65
400 65
7007055 18
RM
55 #N/A
30
25
01 02 03 04
RM RM RM RM EA
16 21 33 10 2600
40 50 50 25 2500
20 7007061 7007062 21 7007063 7007064 22 7007065 01 7007066 02 7007067 23 7007069 24 7007070 25 7007071 26 01 02 01 02
#N/A RM RM 100 100 #N/A 182 205 #N/A 570 620 171 200 342 2750 50 50 50 50
EA EA
150 175
140 175
EA EA EA EA EA EA
#N/A EA EA EA EA EA #N/A #N/A 3500 2520 1540 900 1000 3000 600 100 3000 2000 2250
Installation of 2T Tank and 2T Mix attachment with the existing pump(excluding the pipeline cost).Cost includes supply and fabrication of Channels100x50x6mm and installing in cc base, painting complete. Providing sampling facility arrangement in 2T Tank.Rate to include providing necessary locking arrangement and brass stop cock. Supplying and fixing 20mm dia heavy duty brass stop cock of a quality ESCO make or equivalent Supplying & fixing of 50 mm dia PV valve on vent pipe of Metalpower or approved make.(setting:10 In. pressure & 1 In. vacuum of water column).
Page 49 of 111
2250
EA EA EA
DESCRIPTION OF WORK Nuts/Bolts for manhole cover of tank/flanges(GKW make) Supplying holding down bolt for 10/15/20/45 KL U/G tanks as per our std. WHITE WASHING / PAINTING : Preparing surface and painting with cement paint of Snowcem or approved make, shade and quality, in all heights of walls,ceiling, sun shades fins etc. incl. providing scaffolding,cleaning, curing and supply of all materials and labour complete. 2 coats Each additional coat Preparing surface and white wash incl. glue, blue in all heights of walls, ceiling, sun sheds fins etc. incl.providing scaffolding, cleaning, curing and supply of all materials and labour complete. 2 coats Each additional coat Preparing surface and painting with colour wash of approved make, shade and quality in all heights of walls, ceiling,sun shades fins etc. incl. providing scaffolding, cleaning,curing and supply of all materials and labour complete. 2 coats Each additional coat Preparing surface and painting with Oil Bound distemper of approved make, shade and quality in all heights of walls,ceiling, sun sheds fins etc. incl. providing scaffolding,cleaning, curing and supply of all materials and labour complete. 2 coats For each additional coat Preparing surface and painting with Water Bound distemper of approved make, shade and quality in all heights of walls, ceiling, sun sheds fins etc. incl. providing scaffolding, cleaning, curing and supply of all materials and labour complete. 2 coats For each additional coat Preparing surface and painting with Plastic Emulsion of approved make, shade and quality in all heights of walls,ceiling, sun sheds fins etc. incl. providing scaffolding,cleaning, curing and supply of all materials and labour complete. 2 coats For each additional coat Painting of hoarding after scrapping to metal surface and then applying two coats of metal primer and painting message/art work with two coats of approved enamel paint as per our colour shades. Painting on existing hoarding with message/art work by applying two coats of approved enamel paint as per our colour shades. Painting as per standard colour scheme in letters of following height 25mm 50mm 75mm 100mm Scrapping surfaces, steel doors, windows with wire brush or cleaning masonry surface with coir brush or preparing the surface and applying following paints of approved make,shaquality incl. Supply of all materials and labour with two coats Providing and pasting Plaster of Paris to any surface to achieve an uniform and smooth finish Anti - Fungal, Anti - Algai Exterior Paint (Apcolite Apex Exterior Paint) of Asian Paints of or equivalent approved shade, in two coats as per the instructions of the manufacturers; giving uniform shade etc. Scrapping surfaces, steel doors, windows with wire brush or cleaning masonry surface with coil brush or preparing the wooden surfaces and applying following paints of approved make/shade/quality incl. Supply of all materials With two coats of Red oxide primer
Page 50 of 111
UNIT Kg Kg
75 75
OLD SOR 65 50
7007156 7007157 2
01 02
M2 M2
44 12 #N/A
30 40
30 40
7007158 7007159 3
01 02
M2 M2
16 6 #N/A
10 4
10 4
7007160 7007161 4
01 02
M2 M2
16 6 #N/A
10 4
10 4
7007162 7007163 5
01 02
M2 M2
41 16 #N/A
32 12
32 12
7007164 7007165 6
01 02
M2 M2
28 13 #N/A
20 10
20 10
01 02
M2 M2 M2
91 20 219
70 17 190
70 17 190
M2
170
170
01 02 03 04
EA EA EA EA M2
7 7 7 7 85
7 7 7 7 85
7007177 11
M2
#N/A
60
60
12
#N/A
7007178
01
M2
28
20
20
SERVICE NO 7007179 7007180 7007181 7007182 7007183 7007184 7007185 7007186 7007187 13 02 03 04 05 06 07 08 09 10
DESCRIPTION OF WORK With one coat of Red oxide primer With two coats of Aluminium paint With two coats of synthetic enamel paint with one coat of primer With two coats of synthetic enamel paint For each additional coat of enamel paint With two coats of wood primer With one coat of cement primer 2 coats of cement primer Zebra painting to pump pedestal Surface preparing, wire brushing, cleaning emblem post/light posts incl. fixtures and painting the same with approved quality/make/shade paints as under : Rate incl.cost of all materials and labour One coat of Red Oxide primer Two coats of Red Oxide primer Two coats of Enamel paint Two coats of Aluminium paint Cleaning, surface preparing and painting MONO dispensing pumps both externally and internally incl.sub-assemblies and other components as per our standard colour scheme with approved quality make paint incl. lettering monogram etc. complete. Rate includes cost of material and labour. 1 coat of Red Oxide primer & 2 coats of enamel paint 2 coats of enamel paint only Cleaning, surface preparing and painting DUO dispensing pumps both externally and internally incl.sub-assemblies and other components as per our standard colour scheme with approved quality make paint incl. lettering monogram etc. complete. Rate includes cost of material and labour. 1 coat of Red Oxide primer & 2 coats of enamel paint 2 coats of enamel paint only Cleaning, surface preparing and painting MPD dispensing pumps both externally and internally incl.sub-assemblies and other components as per our standard colour scheme with approved quality make paint incl. lettering monogram etc. complete. Rate includes cost of material and labour. 1 coat of Red Oxide primer & 2 coats of enamel paint 2 coats of enamel paint only Cleaning, surface preparing and painting MONO/DUO pumps externally as per our standard colour scheme. Rate includes cost of material and labour One coat of Red Oxide primer and two coats of Enamel paint Two coats of Enamel paint only Cleaning, surface preparing and painting MPD pumps externally as per our standard colour scheme. Rate includes cost of material and labour One coat of Red Oxide primer and two coats of Enamel paint Two coats of Enamel paint only Cleaning, surface preparing and painting primemover/ Bulkmeter at Depot/Consumer premises externally as per our standard 'colour scheme. Rate includes cost of material and labour One coat of Red Oxide primer and two coats of Enamel paint Two coats of Enamel paint only Part painting new pump for product identification and other necessary changes. Rate includes cost of paint and labour and sticker cost Mono Pump Duo Pump MPD of all types Scrapping, wire brushing, cleaning the pipe surface and applying approved quality/make paint as per our standard colour scheme complete incl. cost of material and labour one coat of red oxide primer and two coats of enamel paint
Page 51 of 111
UNIT M2 M2 M2 M2 M2 M2 M2 M2 RM
14 45 70 55 17 22 15 18 80
OLD SOR 14 45 70 55 17 22 15 18 80
01 02 03 04
EA EA EA EA
7007192 7007193 15
01 02
EA EA
550 500
550 500
7007194 7007195 16
01 02
EA EA
600 550
600 550
01 02
EA EA
825 715
825 715
01 02
EA EA
350 300
350 300
01 02
EA EA
400 350
400 350
01 02
EA EA
200 175
200 175
01 02 03
EA EA EA
DESCRIPTION OF WORK Vent , dip and fill points HSD visible filter Painting panel with BPCL emblem on Sales Room incl. cost of paint & labour Size 1m x 0.8m Painting Company's name (Logo) in standard colour letters in English and Hindi or Regional languages incl. cost of paint Painting "NO SMOKING" "ENTRY" "NO ENTRY" "EXIT" "NO EXIT"NO PARKING" signs incl. cost of paint (Each message to be paid separately) Painting Storage Licence No. on the Sales Room incl. cost of paint. Wire brushing, scrapping, cleaning the pipeline and fittings and applying 'two coats each of Red Oxide primer of approved make/shade/quality Enamel paint incl. cost ofl abour and material complete 40 mm dia pipe 50 mm dia pipe 80 mm dia pipe Wire brushing, scrapping, cleaning both sides of Sump cover and applying two coats each of approved quality/make/shade Red Oxide primer and Synthetic Enamel paint complete incl.cost of labour and paint Wire brushing, cleaning the angle iron post of fencing and applying two coats each of approved make/quality Red Oxide primer and Aluminium paint complete incl. cost of material and labour Coir brushing, cleaning the RCC post of fencing and applying two coats of White wash incl. blue and glue complete Polishing the wooden surfaces with three coats of French polish of required shade incl. surface preparation like applying sand paper, filling required shade incl. surface preparation like applying sand paper, filling small holes/cracks/scratches with Putty before applying French polish complete Painting as per our standard : Telephone nos. of Police Station, Fire Brigade, Hospitals etc. in the Sales Room incl. cost of paint Preparing the surface with wall putty of approved make, for interior wall before final painting - 2 coats Preparing the surface with wall putty of approved make, for interior wall before final painting - 3 coats
UNIT EA EA EA EA EA EA
RM RM RM M2
13 15 19 99
10 12 15 80
10 12 15 80
7007217 28
EA
55
40
40
7007219 29 7007221 30
EA M2
14 246
12 200
12 200
7007223 31 32 33 34 7007224 35 36
EA
355 #N/A
300
300
M2 #N/A M2 Applying Birla white wall putty or equivalent make, 3 coats to make the existing plastered surface smooth over the walls, necessary scaffolding etc., complete- Exterior wall surface Painting as per our std Complaint/Suggestion/SO name/Territory address telephone nos/ dealer's name and address etc., complete I/c cost of paint Scrapping the old paint, cleaning and applying two coats of each of approved make/quality and colour as per our standard to the following 'items : Rate includes cost of material and labour 01 02 03 04 05 06 07 08 10 11 1 Fire buckets incl. writing "FIRE" Fire Extinguisher incl. writing "FIRE" Fire bucket stand Air Tower incl. writing "AIR" Fan Flushing tanks of WC MS ladder of height 4-5 m with two coats of enamel paint Chain-link fencing incl. Post with two coats of aluminium paint Pump guard with two coats of enamel paint Flower pots DISPLAY RACKS S/F display rack made of marine Ply shelves incl. painting with one coat of primer and 2 coats of enamel paint. #N/A M2 EA 355 #N/A 300 300
7007225 7007226 7007227 7007228 7007229 7007230 7007231 7007232 7007234 7007235
EA EA EA EA EA EA EA M2 EA EA
42 35 125 50 50 120 40 45 25
42 35 125 50 50 120 40 45 25
Page 52 of 111
SERVICE NO 7007237 01
DESCRIPTION OF WORK Top portion made of 6mm marine ply backing &19mm marine ply there on with 1.5mm thick matt finish Formica making grooves horizontally of 10mm for fixing glass shelves,incl making pelmet on top with Anofoil reflectors for illumination Bottom portion display rack 0.75m height x 0.6mdeep with 6mm marine ply backing 19mm marine ply sides/top/bottom/front all external surface should be covered with matt finish 1.5mm thick FORMICA incl. Door brass hings, handles, stopper Providing cutting and machine polishing the 12mm thick glass edges of required size and shape as directed by the Engineer. Providing plywood for the racks/shelving of Duro or National make,complete with material and labour 4mm. thick 6mm. thick 12mm. thick 19 mm. thick 4mm thick perforated hard board of approved make 4mm thick plain hard board Providing and fixing lubricant display cabinet made of 6mm ply wood on the back portion, 19mm on all sides and 25mm tk plywood for horizontal portions to stack lubricants with 1mm thick laminate along with teak wood beading for front face I/c painting with enamel paint. Without covered shelves With covered shelves DEPOT Painting 2 coats of enamel paint including surface preparation 3 Inch Valves 4 Inch valves 6 Inch valves 8 Inch valves 10 inch valves 12 inch valves 14 inch valves 18 inch valves 20 inch valves Pumping units motor starter Removing and refixing the following items 3 In. Valve 4 In. valve 6 In. valve 8 In. valve 10 In. Valve 12 In. valve 14 In. valve 18 In. valve 20 In valve flow meter Providing 3 mm compressed asbestos gasket for 3 In. 4 In. 6 In. 8 In. 10 In. 12 In.
Page 53 of 111
UNIT M2
3700
7007238
02
M2
7290
6750
6750
03
M2
2700 #N/A
2500
2500
01 02 03 04 05 06
M2 M2 M2 M2 M2 M2
01 02
M2 M2
01 02 03 04
05 06 07
EA EA EA EA EA EA EA EA EA EA EA EA
01 02 03 04 05 06 07 08 09 10
EA EA EA EA EA EA EA EA EA EA
01 02 03 04 05 06
EA EA EA EA
4644 5940 #N/A #N/A 50 78 146 196 #N/A #N/A #N/A #N/A #N/A 291.2 145.6 100.8 #N/A #N/A 252 280 425.6 728 #N/A #N/A #N/A #N/A #N/A 672 #N/A #N/A 84 140 201.6 291.2 #N/A #N/A
4300 5500
4300 5500
225 250 380 650 700 725 750 775 800 600
225 250 380 650 700 725 750 775 800 600
SERVICE NO 07 08 09 4 7006230 7006231 7006232 7006233 01 02 03 04 05 06 07 08 09 5 7006234 7006235 7006236 7006237 01 02 03 04 05 06 07 08 09 6 7006238 7006239 7006240 7006241 7006242 7006243 7 7006244 7006245 7006246 7006247 7006248 01 02 03 04 05 06 07 08 09 10 8 7006249 7006250 7006251 7006252 7006253 01 02 03 04 05 06 07 01 02 03 14 In. 18 In. 20 In Providing gland packing for 3 In. Valve 4 In. valve 6 In. valve 8 In. valve 10 In. Valve 12 In. valve 14 In. valve 18 In. valve 20 In valve
DESCRIPTION OF WORK
UNIT
EA EA EA EA EA EA EA EA EA
Painting colour code including colour bands, writing name of product and arrow showing direction of flow as per for the pipelines 3 In. 4 In. 6 In. 8 In. 10 In. 12 In. 14 In. 18 In. 20 In Writing letters of sizes 3 In. 4 In. 6 In. Providing MS C class pipe of the following sizes. 4" 6" 8" Providing SORF flanges of std. Specification of the following sizes. 2 In. 3 In. 4 In. 6 In. 8 In. 10 In. 12 In. 14 In. 18 In. 20 In Providing blind flanges of std. Specification of the following sizes. 2 In. 3 In. 4 In. 6 In. 8 In. 10 In. 12 In.
Page 54 of 111
New SOR #N/A #N/A #N/A #N/A #N/A 39.2 50.4 61.6 67.2 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 112 140 168 179.2 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 20.16 30.24 39.2 #N/A #N/A #N/A #N/A #N/A #N/A 280 455 650 780 1040 #N/A #N/A #N/A #N/A #N/A #N/A 318.5 416 559 689 884 #N/A #N/A
35 45 55 60 70 75 80 85 100
35 45 55 60 70 75 80 85 100
EA EA EA EA
EA EA EA RM RM RM
EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA
250 350 500 600 800 800 900 1000 1100 1200 245 320 430 530 680 700 720
250 350 500 600 800 800 900 1000 1100 1200 245 320 430 530 680 700 720
DESCRIPTION OF WORK 14 In. 18 In. 20 In Pressure testing hoses as per standard including removing refixing valves etc.. tank wagon hoses tank lorry hoses tank lorry filling hoses Servicing of transformer upto 500KVA checking of oil level drying of silica collection of oil sample get it tested from authorised parties and producing certificate. Reconditioning earth pits including replacing sand/char coal Construction of Oil/Water Interceptor of size 6.30 x 1.50 x 2.4 M including Oil removal pit. Job includes excavation in ordinary soil, laying of 75mm thk PCC 1:4:8, 200mm thk CC 1:2:4 with 1.5% reinforcement by volume, Brick Masonry with CM 1:5 and Plaster with coarse sand in CM 1:4 (I/c water proofing compound of 1kg per 50 kg of cement) with neat cement slurry finish. Also including laying of 300mm Top slab in 1:2:4 with 2% & fixing of 600X600 manholes (4nos)made out of 16mm thk MS plate & Angle 50 x 50 x 6. With all material/labour. Providing labour for miscellaneous works as directed person / day Earth testing of tanks/ motors/ building etc complete in the installation / depots Opening of covers cleaning and polishing the terminal points for better contact and close of switches/starters Push button switches FLP Non FLP Starters FLP Non FLP O.C.B FLP/Non FLP Painting of above ground tanks with 2 coats of Zinc phosphate paint and 2 coats of aluminium/ enamel paint including scaffolding etc Painting of a/g pipelines with 2 coats of Zinc phosphate paint and 2 coats of aluminium/ enamel paint Pressure testing FOR PIPE LINE with water as per std. practice (min 1.5 times more than working pressure) incl. emptying the product from the pipelines and draining the water after hydrotest complete, rates excluding cost of water. 3" 4" 6" 8" 10" 12" 14" 18" 20" PRESSURE TESTING OF PV VALES, PV as per standard practice, and submitting documents. AUDCO plug/ GATE VALVES SERVICING & PRESSURE TESTING A) 3" A) 4" A) 6" Providing ELBOES of std. Specification of the following sizes. A) 3" A) 4" A) 6"
Page 55 of 111
UNIT EA EA EA EA EA EA EA EA EA
New SOR #N/A #N/A #N/A #N/A 224 224 224 5600 896 39200
OLD SOR 750 775 800 200 200 200 5000 800 35000
13
#N/A
01 02 01 02
EA EA EA EA EA M2 M2
#N/A 252 252 #N/A 252 252 #N/A 616 210 250 #N/A
RM RM RM RM RM RM RM RM RM
#N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A
35 40 40 50 50 60 60 70 75
35 40 40 50 50 60 60 70 75
EA EA EA
EA EA EA
SERVICE NO 110 111 112 113 19 114 115 116 117 118 119 120 20 121 1
DESCRIPTION OF WORK A) 8" A) 10" A) 12" A) 14" Providing TEE of std. Specification of the following sizes. A) 3" A) 4" A) 6" A) 8" A) 10" A) 12" A) 14" Measuring the Earth Pits value of the existing earth pits with & without connecting the electrodes. CANOPY CANOPYSTRUCTURE : Design fabrication and installation of pre-engineered / pre- fabricated steel canopy as per the following specification :The canopy steel structures to be designed considering roof live load of 50 kg per Sq.m in addition to the dead weight of the steel and roof sheeting + false ceiling weight. Also additional 300kg point load to be considered at all canopy corner locations & weight of glow facia @20kg/m may also be considered for designing.The canopy should be designed to withstand the wind speed of 150 km /hour or as per IS : 875, whichever is higher. The design should be safe against bending, twisting, deflection, over turning etc. as per IS : 800. The canopy column should be rectangular box section of 400mm x 200mm x 6mm. Alternatively, the column can be built using ICMC 200 channels welded with 6mm plates so as to give the finished rectangular columns of 400mm x 200mm x 6mm.All steel structure should conform to IS : 2062. Only branded steel like TISCO, SAIL, ESSAR, LIoyd to be used.The depth of the roof canopy structure will be so designed so as
UNIT EA EA EA EA EA EA EA EA EA EA EA EA
New SOR #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A
600 650 650 650 600 600 600 600 700 700 700 700
OLD SOR 600 650 650 650 600 600 600 600 700 700 700 700
#N/A to receive illuminated box facia of 800 mm size all around.The canopy beam structure steel to compromise of built up plate I section / hot rolled I beam / angle truss SHS / RHS tubes as per design and all secondary purlins should be cold formed galvanized Z sections with 275 gsm galvanisation total both sides & yield strength of min.345 mpa only. Alternatively TATA tube with 275 gsm galvanization total both sides may used for purlins. All the primary and secondary connection bolts shall be grade 8.8 both the primary and secondary connection bolts shall be Electro - galvanised of precision fasteners (Unbrako) , Laxmi Precision, GKW, TVS make only.Necessary roof bracing , Wind girders and other forms of bracing to be considered for the overall facility of the structure and the transmission of lateral loads to the column , to and to stabilize the canopy movement as well as strengthen the cantileverHeight of the canopy will be between 4.5mtrs to 6 mtrs from the finished driveway level.N.B. : (I) While designing the #N/A canopy , weight of the canopy should be min. 35 kg per Sq.m upto max of 38.5 Kg per Sq. m. (Wt. over and above 38.5 Kg. per sq.m shall be paid seperately) (ii) In certain cyclone prone areas , swirling speed should be taken into a/c while designing the canopy.ANCHOR BOLTSThe bolt materials shall conform to IS 2062 with a min yield strength of 240 mpa. The lower end of the anchor bolt should be bent with a min radius of curvature of 3d ( dia of the bolts ) The upper exposed portion of the bolt should have min threaded portion of 115 mm (min) with one hexagonal nut followed one hexagonal lock nut.PAINTING Painting the steel structure with two coats of Red oxide Zinc chromate primer or yellow primer and column with addl. two coats of white enamel paint of approved make.ROOFINGGI roofing with trapezoidal profile manufactured by cold roll forming process with 0.63 mm thick (TCT) based galvanization of 275 gsm total both sides with a yield strength of 240 mpa (min), conform to IS : 277 manufactured by SAIL/ JINDAL/ METACRAFT /M/s INTERARCH/M/s METACOLOUR/ M/s NIPPON DENRO/M/s TIGER STEEL/M/s KIRBY BUILDERS.Fastening ,
Page 56 of 111
SERVICE NO
DESCRIPTION OF WORK Laying & Fixing method :-The sheets shall be supplied , preferably , in long transportable lengths upto 11.5 m to avoid longitudinal laps in the roofing systems. The sheets shall be fixed to the purlins by GI self -tapping screws of size 6.3 x 25 with EPDM bonded washer, fixed through the troughs of the profile sheet. All the side laps should be a double corruption side lap and butyle indeal tape to be provided between the top & bottom sheets at the side lap location and stitched with close end aluminium rivets. Longitudinal laps, if any, should be minimum 200 mm with one row inseal tape and one row silicon sealant for leak proof performance.FLASHINGRidge flashing shall be trapezoidal matching the roof profile and bent to the ridge angle. All the other flashing to be manufactured out of the same material and thickness as that of roofing, Wherever the flashing interface with trapezoidal profile roofing, filler blocks should be provided in the gaps and sealed with silicon sealant for leak proof performance. After the installation the roof should be cleared
UNIT
OLD SOR
#N/A of all the metal wastes, screws, nails etc.Necessary profiled filler box should be provided at the higher level of roof sheeting & also at the valley gutter in order to ensure water tightness in the profile gaps.All external flashing in the roof all around excluding gutter are to be of the same material and thickness as roof sheeting.GUTTER & DOWNPIPEGutter shall be manufactured out of 0,91 mm th. Plain aluminium sheets in lengths of 2.5 - 3 m min.(Longer lengths preferred). All the gutter joints shall be fixed by bulb tight rivets and silicon sealant shall be applied all over the joint for leak proof performance. The gutter end caps shall be provided at either ends and duly sealed with silicon sealant. The opening shall be made in the gutter for down spot position with sleeves fixed on the gutter and connecting the sown take pipe. Silicon sealant to be applied all over the joints to ensure water tightness. The gutter slope shall be in such a way that the water collected from the roof move on the down take pipe smoothly without stagnation of water at any point of #N/A the gutter.Size & Shape of the gutter will be trapezoidal section of min. 400mm x 300mm with min. 200 mm depth for effective drainage of the storm water depending upon the rainfall to be designed by the supplier and approved by BPCL. For effective drainage of storm water, the down pipe will be heavy duty PVC drain pipe (100-150 mm depending on design) running inside coloumns. Cost of clamp, brackets and accessories etc. to be included in the cost. Please note no structural member to be used as a gutter.Gutter to be tested with water filled for 48 hrs to ensure it is water tight.FACIAProvision to be made for fixing 800mm wide facia as per new RVM to be provided along with the canopy sides. The weight of the facia as per new RVM on the front & the sides to be considered while designing canopy. The canopy supplier would liaise with the site engineer and make arrangement for cutting of false ceiling for installing electrical fittings/fixture as directed.In the non illuminated portions, plain channel of size 815 mm deep x #N/A 25mm flange x 2mm thick shall be provided. The materials shall be HR sheets conforming to IS 2026 with a min yield strength of 240 mpa . The facia channel shall be supplied duly painted with a primer & fixed on to the structure with countershunk screw.The canopy supplier should provide the following :-DOCUMENTS1. Column reactions on foundation2. GA drawing for the proposed canopy3. Erection Drawing - 2 Sets4. As built drawing - 2 sets5. Structural stability certificate for canopy structure along with design calculation, connection design base plate etc.6.Test certificates of structural steel, fasteners, roofing, false ceiling materialsNOTE:The canopy steel structure should have the provision for installation of False Ceiling Panels System. This shall comprise of the following :1. False Ceiling Runners of suitable section to be cold rolled formed "Z" section made out of GI coils with 275 gsm galvanised and yeild strength of 345 mpa or galvanized tube section/ equivalent structural members.2.The spacing of runner should be 1.2 m - 1.5 m based on canopy dimensions.3. The false ceiling runners to be fixed to main structure by cleats with adjustable holes for level adjustments to be located in the rafters. ALTERNATE FOR ROOFING SHEET : Trapezoidal roofing profile manufactured out of 0.47 mm TCT bare galvalume sheet with grade Az 150 (55% aluminium, 43.5% zinc &1.5%silicon) from reputed make. Height of the canopy 4.5mtrs from the finished driveway level to bottom of false ceiling. Height of the canopy 5mtrs from the finished driveway level to bottom of false ceiling.
Page 57 of 111
#N/A
7007640 7007641
01 02
M2 M2
0 3400
2771
2825
DESCRIPTION OF WORK Height of the canopy 6mtrs from the finished driveway level to bottom of false ceiling. Height of the canopy 4.5mtrs from the finished driveway level to bottom of false ceiling.( with out runners for false ceiling) Height of the canopy 5mtrs from the finished driveway level to bottom of false ceiling.( with out runners for false ceiling) Height of the canopy 6mtrs from the finished driveway level to bottom of false ceiling.( with out runners for false ceiling) FALSE CEILINGScopeThe Scope of this specification covers the design, manufacture, prefabrication, transportation, installation and commissioning of the complete false ceiling system. However, all items required for the safe and efficient maintenance of the false ceiling.A. Materials of Panel :A. 1 : Cold rolled steel confirming to IS 513 having yield strength of 240 mpa (minimum).A. 2 : Base metal thickness should not be less than 0.5 mm.B. Design criteria :B 1 : Ceiling system to be designed to withstand wind velocity of 220 KMPH and relevant seismic factor to the specific location where the false ceiling is to be installed or wind load as per IS 875 Part III whichever is higher.B 2 : System to be has to be designed as fixed system in which false ceiling panels are fixed to the false ceiling runner ( already supplied with canopy ) by suitable designed GI clips or carrier. One end of the clip or carrier is fixed to the false ceiling runners by the bolt of suitable design and other end of the clip or carrier is designed to hold interlocking ends of the ceiling panels. Incase of carrier the cut outs hold the panels should be suitably designed taking into consideration of the material / pressure created by air inside the false ceiling B 3 : the flashing, capping and trims shall be manufactured from the same materials and colour as the ceiling materials. These are fixed with aluminium rivets or stainless pins B4 : maximum deflection of sheets (panels) is limited to L/325 maximum as per IS 800 deflection criteria C. Panel specifications C1: Rolled formed ceiling panels of 150 F/200 F including suitable designs of tongue and groove interlocking should be coated with Zinc in a minimum thickness of 175 GSM on both sides. The panel should be finished with 15 to 18 micron polyester top coat 10 micron thickness. The total coated (TCT) should not be less than 0.6 mm. Colour of the panel shall be white matt finish. NOTE : Supplier has to visit the site before supply of materials at site and get familiarised with the wind velocity, seismic (earthquake) factor and accordingly design of false ceiling to be done and submit the design calculation and drawing details to BPCL. After completion of work, supplier has to submit warranty certificate from manufacturer of panels to BPCL. Supplying and fixing 0.5mm thick Meta colour/poly steel roofing sheet with necessary poly propelene washers self trapping screws etc complete items for fixing the roofing sheet in position. 01 02 Trapezoidal profile Plain sheet Colour Coated GALVALUME roofing with trapezoidal profile manufactured by cold roll forming process with 0.55mm thick (TCT) based galvanization of 275 gsm total both sides with a yield strength of 240 mpa (min), conform to IS : 277 manufactured by SAIL/ JINDAL Supplying and fixing GI roofing sheet 0.63mm thick (TCT) with galvanisation of 275 gsm total both sides with a yield strength of 240 Mpa (min) as per IS:277 Providing and fixing MS Fascia sheet 18 gauge (1.257mm) for Canopy Dismantling and removing Glow Facia 800mm/600mm wide including scaffolding charges Fixing the supplied 800mm/600mm wide Glow Fascia including scaffolding charges Supplying new Aluminium gutter -GUTTER - Gutter shall be manufactured to required shape, made out of 0.95 mm th.(20 g) Plain aluminium sheets in lengths of 2.5 - 3 m min.(Longer lengths preferred). All the gutter joints shall be fixed by bulb tight rivets and silicon sealant shall be applied all over the joint for leak proof performance. The gutter end caps shall be provided at either ends and duly sealed with silicon sealant. The opening shall be made in the gutter for down spot position with sleeves fixed on the gutter and connecting the down take pipe. Silicon sealant to be applied all over the joints to ensure water tightness.
UNIT M2 M2 M2 M2 M2
2771
#N/A
#N/A
#N/A
M2 M2 M2
650 625
650 625
M2 M2 RM RM M2
Page 58 of 111
SERVICE NO 8000574 10
DESCRIPTION OF WORK Providing printed flex materials for hoarding, banner etc. The flex shall be 13 oz (450 gsm) of 3M/Panaflex/LG/Hanwa make. Printing shall be minimum 800 DPI with minimum of four passes. Conducting field soil investigation using Standard Penetration test. The test shall be carried out upto an N value of 50 or refusal strata whichever occurs earlier. The cost includes sinking borehole and collecting sample at regular intervals.The cost of transportation of equipments to site and back shall be extra. Payment shall be made per borehole. Conducting Grain size analysis, Atterberg limits, Natural density-moisture content, Triaxial test, consolidation test on clayey soil, free swell index test on soil sample at laboratory. Rate includes submission of detailed report. Payment shall be made per borehole. NEW RVM Modification to pedestal to accommodate new RVM standards Providing and fixing Marbo granite or equivalent approved make tiles on Pump pedestal as per new RVM Standards. Cleaning and painting two coats of white polyurethene paint on existing Canopy false ceiling surfaces. Rate includes scaffolding cost. Cleaning and painting two coats of yellow/Blue polyurethene paint on existing Canopy facia surfaces. Rate includes scaffolding cost and cost of Blue/Yellow vinyl stickers. Supply and fixing of Ceramic wall tiles 400mmX250mm ("Kajaria Smoke brown / Smoke Kotto" or equivalent for bottom and "Kajaria crema" or equivalent for top as approved) Supply and fixing of ceramic border tiles of "Kajaria" or equivqlent of approved make 75mmX250mm Supply and fixing of Ceramic floor tiles ("Kajaria Stoneto Biege" or equivalent as approved) Supply and fixing of Urinal "Parryware Magnum" or equivalent as approved Supply and fixing of Sensor flushing valves for urinal "Jaquar" or equivalent as approved. Supply and fixing of Sensor Faucet for wash basin "Jaquar" or equivalent make as approved Supply and fixing of 40 mm flush valve "Jaquar" or equivalent make as approved. Supply and fixing of Automatic Hand Drier "Avro" or equivalent make as approved Supplying of Polycrete nosing as per the specifications as given in enclosed Annexure I End pieces as per standard specifications Straight pieces as per standard specifications Erection of following supplied items as per standard specifications including cost of concreting, labour, hardware and making electrical connections complete "In & Out" signage Dealer name unit Banner stand pole mounted Polycrete pedestal nosing - End piece Polycrete pedestal nosing - Straight piece Poster unit Providing pump graphics including cleaning & levelling the surface and providing 2 coats of primer as per standard specification.The standard design as given in Annexure II to be printed on 3M or Avery make vinyls using automatic / semiautomatic screen printing platform with the inks and clear coat as suggested by vinyl manufacturers. The final graphic displaying vinyl to be edge sealed. The opacity of such graphics and vinyl combined on a backlit surface will require to be more than 98%.Such screen printing including vinyl will carry 5 years warranty for outdoor / indoor application, from vinyl supplier only.In order to have combined warranty for vinyl and screen printing from vinyl manufacturer i.e. 3M or Avery, screen printing and printers shall be as per vinyl manufacturer advice. These screen-printed vinyls will have gasoline resistance property as these are to be fixed in "all the time vapour present area". The warranty will be against print quality failure, colour fadind,adhesion loss and shrinkages etc. Schlumberger - Mono (720X680mm) Schlumberger - Duo/MPD(1080X680 mm) Gilbarco DUO - Advantage(1072X507mm)
Page 59 of 111
UNIT M2
OLD SOR
8000576 11
EA
14200
10000
7007778 1 8000577 2 7007990 3 7007991 4 8000578 5 8000579 6 8000580 8000581 8000582 8000583 7 8 9 10
RM M2 M2 M2 M2 EA M2 EA EA EA EA EA EA RM
#N/A 403 4025 230 250 978 144 978 2645 10925 12000 2875 9200 #N/A #N/A #N/A #N/A 259 144 259 600 259 259 #N/A
350 3500 190 200 840 120 820 2200 9500 10000 2300 7500 7125 1500
800 100 800 1975 10000 10000 2500 8000 7200 1530
8000584 11 8000585 12 13 8000590 01 8000591 02 14 7007717 7007718 7007720 8000592 8000593 8000594 15 01 02 03 04 05 06
EA EA EA EA RM EA
01 02 03
EA EA EA
SERVICE NO 8000598 8000599 8000600 8000601 8000602 8000603 8000604 8000605 8000606 8000607 NEW 16 04 05 06 07 08 09 10 11 12 13 14
DESCRIPTION OF WORK Gilbarco Mono - Advantage(768X507mm) Gilbarco MPD (Small Panels) - Euroline(370X800mm) MIDCO (980 CP) Mono (640X920mm) MIDCO (990 CP)(640X1055mm) MIDCO - Bullet Mono(480X1120mm) MIDCO - Bullet DUO(655X1120mm) L & T "Z" Line(610X610mm) L & T Pacemaker DUO(610X705mm) Nuovo Pignone MPD(1070X540mm) Any other model Outdoor Payment Terminal ( OPT ) Providing only spreader graphics including cleaning & levelling the surface.The standard design as given in Annexure III to be printed on 3M or Avery make vinyls using automatic / semiautomatic screen printing platform with the inks and clear coat as suggested by vinyl manufacturers. The final graphic displaying vinyl to be edge sealed. The opacity of such graphics and vinyl combined on a backlit surface will require to be more than 98%.Such screen printing including vinyl will carry 5 years warranty for outdoor / indoor application, from vinyl supplier only.In order to have combined warranty for vinyl and screen printing from vinyl manufacturer i.e. 3M or Avery, screen printing and printers shall be as per vinyl manufacturer advice. These screen-printed vinyls will have gasoline resistance property as these are to be fixed in "all the time vapour present area". The warranty will be against print quality failure, colour fadind,adhesion loss and shrinkages etc. For spreaders as per approved product name & fond. Rate for one side. For spreader extension as per approved product name & fond
UNIT EA EA EA EA EA EA EA EA EA FT2 EA
New SOR 2074 2013 2928 3416 2806 3660 2074 2318 3660 244 1540 #N/A
OLD SOR 1700 1650 2400 2800 2300 3000 1700 1900 3000 200 2450 2450 2450 2300 2500 1700 900 3000
7007909 7007910 17
01 02
EA EA EA
2275 1690 #N/A #N/A #N/A #N/A #N/A #N/A #N/A 800 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A 3250 1250 #N/A #N/A #N/A #N/A #N/A 250 150 450 200 1200 30
Fixing of supplied monolith light fixtures including fixing arrangements, commisioning etc complete 18 Installation of Air Compressor including CC foundation,electrical connection,air pipe connection,etc EA 1000
19
Installation of Electronic air gauge in the air signage includingelectrical connection,air pipe connection,etc Supply & Fixing of Perforated vinyl sticker on glass of sales room of approved quality by engg incharge with art work etc complete Providing and Laying Mexican Grass, carpet including cost of all materials, labour etc complete Providing and Laying Mexican Grass, dibbling and planting including cost of all materials, labour etc complete Providing and Laying Vegetation Grade Earth/Manure mixed Earth/for Turfing/Mexican Grass Painting Canopy Facia as Per NEW RVM Colour & Design wave pattern with template design. Providing and Fixing Urinal Partitiuon Suitable for Magnum Model Urinal Cleaning With Soap Solution/Water ACM Facia Building Facia supply & Fixing of Perforated vinyl sticker on glass of sales room of approved quality by engg incharge with art work etc complete CHANGING MONOLITH PANELS A. Including cost of new panel, routing etc complete B. Removing existing panel, routing and fixing back SUPPLYING RATE CARDS FOR MONOLITH - As per standard design, 3 mm thick pet-G A. RUPEE B. PAISE
EA
400
9002446 20 21 15 22 16 23 24 9001096 18 25 19 26
m2 m2 m2 cu.m RM EA M2
550
27 9002442 9002443 28 01 02 01 02
EA EA
3200 1700
EA EA
110 100
Page 60 of 111
SERVICE NO 29
DESCRIPTION OF WORK Aluminim Sheet - Providing and fixing aluminium sheet of 1mm thick, including bending, fixing etc complete for buidlings and other uses.
UNIT M2
30 Providing and fixing GI Sheet metal fascia 18 g for canopy including bending, fixing, painting two coats of primer and two coats of enamel paint as per the site conditions, directed by Engg incharge.
M2
550
NEW NEW
3 5
7 8 9
01 02 01 02
AUTOMATION Supplying and Laying of HDPE pipes of Reliance or equivalent of 6Kg/Sq.cm with minimum shell thickness of 6 mm for automation cables. The cost includes provision of GI pull wire. 90 mm outer dia 75 mm outer dia 50 mm outer dia 32 mm outer dia Supply & Installation of 3" raiser pipe using ERW C class pipe for ATG in existing tanks.Job includes provision of reducers / expanders , Aluminium caps with threaded holes, nipples etc. as directed by Engineer-in-Charge. Same as above without Aluminium cap. Supply & Installation of 3" raiser pipe using ERW C class pipe for ATG in existing tanks.Job includes provision of reducers / expanders , Aluminium caps with threaded holes, nipples etc. as directed by Engineer-in-Charge. Supply & Installation of 4" raiser pipe using ERW C class pipe for ATG in existing tanks.Job includes madification to the manhole plate, provision of reducer with external threading, MS cap with threaded hole etc. as directed by Engineer-in-Charge. Same as above without Aluminium cap. Providing cable pull chamber of 300mm X 300mm X 1000mm with CS (Heavy Duty) cover of reputed make with ISI mark. Fixing of supplied FRP box (both single & double) on MPD. Job includes drilling holes on MPD, drawing communication and power cables (excl cost of cables), providing 2 way telephone jn box and two 5 amp sockets in the FRP boxes etc. Removing and refixing of supplied FRP Box (Both Single & Double) on MPD. Fixing OPT in the pedestal. Job includes providing foundation as per the drawing provided, laying 2 nos 1" pvc pipes from MPD pit to the centre of OPT foundation, fixing OPT etc. Drilling 3 holes on either side of the MPD for fixing the density display Supply and laying of CAT 5 Cable of reputed make like phenolix, d-link etc. as specified by Engineer in - Charge with termination connectors like DB9, RJ45 etc. Supply and laying of CAT 6 Cable of reputed make like phenolix, d-link etc. as specified by Engineer in - Charge with termination connectors like DB9, RJ45 etc. Supply and laying of BELDON Cable with termination connectors like DB9, RJ45 etc. Supply of Thermal paper of 57 mm width as per specifications 17 Mtr roll Supply of Thermal paper of 60 mm width as per specifications 17 Mtr roll (60GSM, storage temperature upto 50C, high oil resistance) Supply of Thermal paper of 80 mm width as per specifications 50 Mtr roll Supply of RS 232 / 485 protocol and baurd rate converters as per the specification Supply of FRP Boxes as per the specification For Single EDC Machine For Double EDC Machine Supply of FRP Box stand as per the specification For Single EDC Machine For Double EDC Machine Supply and fixing of Wireless GPRS Modem as per psecification.
#N/A #N/A #N/A #N/A #N/A #N/A RM RM RM RM EA 445 334 1540 1540 1540 400 270 200 160 1550
EA EA
1540 1540
1350
EA
#N/A
EA EA EA
2500 500
EA EA EA M M M EA
1540 1540 1540 1540 1540 1540 1540 #N/A 1540 1540 #N/A 1540 1540 #N/A 1540 1540 1540
EA EA EA EA EA EA EA
Page 61 of 111
SERVICE NO NEW 22
DESCRIPTION OF WORK Supply and fixing of 12U IT Rack with accessories (powers strip, slotted rails, holding tray, 6" exhaust fan etc) as per specification
UNIT EA
OLD SOR
LIASION WORK 1 BUILDING PERMIT : Preparing necessary application, etc., drawing for building permit and submitting the same to local authorities for issuing building permit and obtaining the same including all liasioning follow up works (Excluding local body fees) From Hyderabad City Corporation Other City Corporation (Vishakapatnam,Rajamundry,Vijayawada,Warangal,Guntur,Nellore&Tirupati) Municipality Town Panchayat Village Panchayat
01 02 03 04 05
10000
01 02 03 3
LIASONING FOR POWER CONNECTION : Preparing necessary application and drawing and submitting the same to the EB authorities and arranging for the POWER CONNECTION including all laisoning / follow ups. Excluding the cost of fees, to be paid. 0 - 25 KVA 25 TO 63 kva ABOVE 63 KVA LIASONING FOR DG Set Approval : Preparing necessary application and drawing and submitting the same to the EB authorities and arranging for the DG Set Approval, including all laisoning / follow ups. Excluding the cost of fees, to be paid. UPTO 45 KVA ABOVE 45 KVA Preparation and submission of necessary application for obtaining water supply and sewage connections from appropriate department, submitting the same to concerned authority and also liasoning with various agencies, approved contractors etc as applicable For GHMC City Corporation area Other City Corporation (Vishakapatnam,Rajamundry,Vijayawada,Warangal,Guntur,Nellore&Tirupati) area Municipality area Town Panchayat area Village Panchayat area Preparation of as built Drawing of existing RO/NEW RO including site visit and measurments 1-50 kms 51-150 kms 151-300 kms above 300 kms Modification and plotting existing Drawings with 6 Nos of Blue prints Only Blue prints for NOC/EXP. As desired. A0 A1 A2 Preparation of Building permission Drawings for desired by local Muncipal Authorities.
01 02 4
6000 8000
01 02 03 04 05 9000504 5 01 02 03 04 6 7 01 02 03 9000504/9000617 8
#N/A #N/A #N/A #N/A #N/A #N/A 4500 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A
EA EA EA EA EA
ea ea ea ea
50 40 25 2000
Page 62 of 111
SERVICE NO New 1
DESCRIPTION OF WORK Site Clearance - Clearing the site using machineries, manual labour etc for removing the bushes, vegetation etc complete including for trees with the size of upto 300 mm dia trunk and disposing the removed items from site to an unobjectionable area outside the site as directed by the Engg incharge. including cost of all labour, machineries, transportation etc complete. Supplying & providing barricading using wooden poles frame & using G.I sheets of 22 gauge, including cost of all materials, labour etc complete, the spacing of supporting vertical and horizontal poles will be as per the site conditions, as approved by engineer incharge. Erecting of supplied barricading using wooden poles frame & using G.I sheets of 22 gauge, including cost of labour etc complete, the spacing of supporting vertical and horizontal poles will be as per the site conditions, as approved by engineer incharge. OTHERS Supply and fixing of precast Heavy Duty RCC manhole cover with outer frame of size 600mmX600mmX150mm for covering Cable chambers and rainwater chambers Supply and fixing of FRP light weight manhole confirming to EN 124 class C250 / AASHTO HS 20. Designed to adhere strictly within standard set by international SHE regulations.Dynamic load test using BS EN 124:1994, compressing load Test according to BS EN 124:1994 EN 124 class C250 rated to 250 KN or 25 metric Ton. 900 mm round 900 X 900 mm square 750 X 750 mm square Transportation of Mislenies Items 1 By Auto 2 By Van 3 By Truck Printing and Fixing Flex on Hoarding Printing and Fixing Flex along with Frame on wall including Frame Work. Checking of Earthing using megger for Pumps/Ups etc. SALARY Supply of Supervision Engineer, for supervising works at site / office related works( Minimum Diploma in respective discipline ) Civil / mech / elect - Per day Civil / mech / elect - Per Month Providing Draftsman with AutoCAD Knowledge for preparing various drawings & blueprints. Rate/Day. Providing skilled / unskilled labour for various work Electrician ( Rate per day) Plumber ( Rate per day) Carpenter ( Rate per day) General Workman ( Rate per day) Providing manpower for semi skilled works like security, gardening maintenance, other miscellaneous works on monthly basis, inclusing cost of all charges, etc complete.- Rate per month per person
UNIT M2
OLD SOR 10
New 2
M2
1540
500
New 3
m2
1540
200
8000588 1 2
EA EA
2200
01 02 03 New 3
EA EA EA Km Km Km
4 5 6
1 01 02 2 3 01 02 03 04 4
#N/A #N/A #N/A 1540 #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A 500 15000 500 400 15000 500
300
Page 63 of 111
DISCOUNTS NIL 2%
8 1463 11704
day Friday
Saturday
Date Discripation 8/7/2011 Evening to wards suryapet FVC -chivemla, Nuthankal, jaajireddygudem - (UIP mugala. 9/9/2011 Suryapet with SO/CG/VENDOR) visit of J.laxaiha for pipeline leak.. Vvendor is already on site. SVOC nalgonada ( layout finalisation, for 10/7/2011 UIP) FVC-munugode , 11/7/2011 thripuraram,anumula,Nakarekal 12/7/2011 FVC-chilkuru, Mattempalli, kodad
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11
1 2 3 4 5 6 7 8 9 10 11 12
40 mm PCC bed 1:4:8 relaying if pavers sand flilling under the pavers vent pipe dismentling of light ploes and pedestal nosing and tiles for pump ilend new trench constrution buffer strip buffer strip slil filling removing of old pipeline tank manhole modifcation new monolith electrical panel yard light removing and refixing emblem pole 3 x 1.5 sq. mm 4 x 1.5 sq. mm earthing GI GI SRTIP coppper earthig cooper wire hume pipe RCC beam
measurement after deduction thnickness measurement 1010 950 0.15 142.5 1010 950 80 1010 950 0.05 47.5 40 875 130
15 5 60 150
1 2 3 4 5 6 7 8 9 10 11
0.3
1.5
0.45
0.3
0.3
30
total 327750 76000 42750 113750 20000 50000 14250 1800 8400
1700 2850 30 56
26000
11700 50000 10000 19600 23400 11900 11800 14000 19500 117000 21060 964660
570,000.00
394,660.00