Sie sind auf Seite 1von 40

Type Series Booklet 1798.

5/5-10

Movitec A
High-pressure in-line pumps with and without speed control 50 Hz

Movitec V(S)

Movitec LHS

Movitec V PD

Applications

Movitec V(S) /-PD and LHS /-PD are used for general water supply, spray irrigation, irrigation and pressure boosting duties, for warm water, hot water and cooling water recirculation, condensate transport. They are installed in boiler feed circuits, domestic water supply systems, washing plants, water treatment and filter systems, degreasing baths/alkaline cleaning agents, alkaline solutions and oils/emulsions, fire-fighting systems, as well as reverse osmosis and surface treatment applications.

Designation
Type series Movitec V Material variant Flange design Size Number of stages PumpDrive

Movitec V

S F 10 -- 3 PD

Design

Movitec LHS 6 -- 10
Type series Size Number of stages PumpDrive Material variant: Flange design/connection: blank or S, see page 3 F = Round flange V = Victaulic coupling

PD

Pump Multistage, vertical (horizontal installation see page 5) high-pressure centrifugal pump, with suction and discharge nozzles of identical nominal diameters arranged opposite to each other (in-line design).

Drive

Without speed control Electric motor, 50 Hz, air-cooled, 2-pole and 4-pole, KSB standard motor with main dimensions to IEC. Other motor makes subject to prior consultation with KSB. Movitec V, VS, LHS with PTC thermistors for motors > 3 kW. Variants: single-phase AC motor, 60 Hz (see type series booklet 1798.56-10). With PumpDrive speed control system Enhanced with PumpDrive, a Movitec pump together with the appropriate sensors is turned into an intelligent, variable speed pumping system, ideal for both single-pump operation and multiple pump configurations with up to six pumps (see type series booklet PumpDrive 4070.5-10).

Operating data
Movitec V(S) /-PD Flow rate Head Operating pressure Operating temperature Movitec LHS /-PD Flow rate Head Operating pressure Operating temperature
1) 2)

Q H pd t Q H pd t

up to 75 m3/h (21 l/s) up to 249 m up to 25 bar 1) --15 _C to +120 _C up to 8.6 m3/h (2.4 l/s) up to 401 m up to 40 bar 1) --15 _C to +120 _C 2)

The sum of inlet pressure and shut-off head must not exceed the value indicated. Discharge pressure < PN 25: up to 120 _C

Conformity mark

CE (all pumps), ACS (Movitec VE / V) ATEX Group II, Cat. 2 and 3 on request (not for Movitec PD)

Movitec A Selection charts


n 2900 1/min

LHS 6

VC 90 V(S) 90 V(S) 2 V(S) 4 V(S) 6 V(S) 10 V(S) 15 V(S) 32 V(S) 45 V(S) 65

For Movitec 2, 4, 6, 10 15 and 90 please refer to type series booklet Movitec B, reference No. 1798.52-10 n 1450 1/min

VC 90 V(S) 90

V(S ) 10

V(S ) 15

V(S) 24

Movitec A Materials
Part No. 101 108 160 171 10-6 210 230 341 412 525 529
1)

Description Movitec V Pump casing Stage casing Cover Diffuser Pump shroud Shaft Impeller Motor stool O-ring Spacer sleeve Bearing sleeve Bearing Baseplate Tie bolt Nut Circlip 1.4301 JL 1040 EPDM 1.4301 1.4301 1.4301 1.4301 1.4301 1.4301 1.4305 1.4301 JL 1040

Material Movitec VS 1.4401 1.4404 1.4404 1.4404 1.4404 1.4401 1.4404 1.4408 VITON 1.4404 Tungsten carbide Ceramics -1.4057 1.4404 1.4571 -Movitec LHS 1.4408

890 905 920 932


1)

Permanently connected with stage casing 108 or diffuser 171

Key to materials
Description Grey cast iron Chrome nickel steel Chrome nickel molybdenum steel Carbon chrome nickel molybdenum steel Chrome nickel molybdenum steel Chrome nickel steel Code and material No. JL1040 / GJL-250 1.4301 / X5CrNi18-10 1.4404 / X2CrNiMo 17-12-2 1.4408 / GX5CrNiMo19-11-2 1.4571 / X6CrNiMoTi17-12-2 1.4057+QT800 / X17CrNi16-2-QT800 1.4305 / X8CrNiS 18-9 1.4401 / X5CrNiMo 17-12-2 1.4308 / GX5CrNi 19-10 Please note: Material designations to ASTM/AISI are not binding. Standard EN 1561 EN 10088 EN 10088 EN 10213 EN 10088 EN 10088-3 EN 10088 EN 10088 EN 10283 to ASTM A48:40B A276:304 A276:316L A743CF8M A276:316 A276:431 A276:303 A276:316 A743:CF8

Bearings
All V , VS and LHS pumps are equipped with tungsten carbide plain bearings at the hydraulic rotor.

Movitec A Shaft seal


Single, uncooled mechanical seal in accordance with EN 12756.

Material codes
Mechanical seal Description Primary ring Mating ring Elastomer Code letter to EN 12756 Q1 U3 B U3 E V X4 G G 13 14 15 16 17 19 Q1BEGG Q1BVGG U3U3X4GG U3U3VGG U3BVGG U3BEGG Material Silicon carbide (sintered without pressure) Tungsten carbide (CrNiMo binder) Hard carbon, resin-impregnated Tungsten carbide (CrNiMo binder) EPDM (ethylene propylene rubber) Fluoroelastomer (Viton) HNBR CrNiMo steel CrNiMo steel Silicon carbide / Hard carbon / EPDM Silicon carbide / Hard carbon / Viton Tungsten carbide/Tungsten carbide/HNBR Tungsten carbide/Tungsten carbide/Viton Tungsten carbide/Hard carbon/Viton (40-bar seal; for Movitec LHS only) Tungsten carbide / Hard carbon / EPDM

Spring Other metal parts Code number

Pressure and temperature limits


Fluid temperature t 3) Flange design/connection Material variant Max. operating pressure ps 1) p 16 to 25 bar 16 to 25 bar up to 25 bar up to 25 bar up to 40 bar up to 25 bar Code number of mechanical seal 5) Standard 13 14 13 14 17 17 Optional 14, 15, 16 13, 15, 16 14, 15, 16 13, 15, 16 19 19

-- 15 _C to + 120 _C -- 15 _C to + 120 _C -- 15 _C to + 80 _C -- 15 _C to + 120 _C 6)


1) 2) 3) 4) 5) 6)

VF

= Round flange 2)

Movitec VF Movitec VSF Movitec VV Movitec VSV Movitec LHS

VSV = Victaulic coupling LHS = Round flange 4)

The sum of inlet pressure and shut-off head must not exceed the value indicated. Drilled to EN 1092-2 PN 25 (optional: ASME B 16.1 Class 250 or JIS B2238 16K) Subject to special application limits (see List of Fluids Handled) Drilled to EN 1092-2 PN 40 Movitec 24, 32 and 45 with motor ratings of 11 kW or higher: cartridge seals; Movitec 65 always with cartridge seal If fluid temperature > 80_C: PN 25, recommended elastomer -- EPDM

Movitec A Horizontal installation


Movitec can be installed horizontally in systems where the installation conditions do not allow vertical installation. Motor flange B14 (0.55 to 4.0 kW) Dimensions of Movitec V, VS 24, 32, 45, 65 Motor rating [kW] C 1) [mm] F2 + 47 F2 + 39 F2 -- 17 F2 + 47 F2 + 39 F2 -- 17 H A B Ident. No. of set 2)

[mm] [mm] [mm] -- 4-pole 170 170 170 170 170 170 180 180 180 -- 2-pole 180 180 180 180 180 180 180 180 180

Movitec VF, VSF 24 1.1 -- 1.5 2.2 -- 4.0 5.5 -- 7.5 1.5 -- 2.2 3.0 -- 4.0 Motor flange B5 (5.5 and 7.5 kW) 5.5 -- 7.5
1)

47 116 969 47 116 970 47 116 971 47 116 972 47 116 973 47 116 974

Movitec VF, VSF 32, 45, 65

For stage-dependent height dimension F2 refer to Movitec type series booklet, page 27ff 2) Not possible for Movitec LHS and PD

The set for horizontal installation includes 2 stainless steel holding brackets and the required fasteners. Foundation bolts must be supplied by the operator.

max. 13 mm for M12 Holding bracket (pump) 89-11.01 Holding bracket (motor) 89-11.02

Movitec A Design features of Movitec V(S)


Universal high-pressure pump up to 25 bar --15 _C to 120 _C Also suitable for chemically aggressive fluids Space saving vertical design Service-friendly, robust three-phase motor Multi-range voltage/frequency Enclosure IP 55 Thermal class F With PTC thermistor > 3 kW

Leak-free and resistant to thermal shocks Floating pump shroud Confined O-rings

Reliable and service-friendly shaft seal Standardised mechanical seal to EN 12756

Easy-to-fit shaft made of high-alloy steel, firm connection between shaft and impeller

Low-noise: Flow noise is damped by pump shroud

Corrosion-resistant: Hydraulic components and pump shroud made of high-alloy stainless steel Movitec V with pump shroud made of CrNi sheet steel

High operating reliability ensured by torsion-proof pump shroud No external joints Only 2 sealing elements

Highly wear-resistant and maintenance-free plain bearing made of tungsten carbide/ceramics, lubricated by the fluid handled Self-cleaning by forced flushing

Simple installation and piping layout thanks to in-line design Insensitive to external nozzle forces and moments

Movitec A Design features of Movitec LHS

Universal high-pressure pump up to 40 bar --15 _C to 120 _C Also suitable for chemically aggressive fluids Space saving vertical design Service-friendly, robust three-phase motor Multi-range voltage/frequency Enclosure IP 55 Thermal class F With PTC thermistor > 3 kW

Leak-free and resistant to thermal shocks Floating pump shroud Confined O-rings

Reliable and service-friendly shaft seal Standardised mechanical seal to EN 12756 Corrosion-resistant Hydraulic components and pump shroud made of high-alloy stainless CrNiMo sheet steel High operating reliability ensured by torsion-proof pump shroud No external joints Only 2 sealing elements

Easy-to-fit shaft made of high-alloy steel, flat shaft end ensures firm connection between shaft and impeller

Low-noise: Flow noise is damped by pump shroud

Highly wear-resistant and maintenance-free plain bearing made of tungsten carbide/ceramics, lubricated by the fluid handled Self-cleaning by forced flushing

Simple installation and piping layout thanks to in-line design Insensitive to external nozzle forces and moments

Movitec A PumpDrive features


Functions Basic
Protective functions Thermal motor protection by PTC thermistors Electrical motor protection by overvoltage/undervoltage monitoring Dynamic overload protection by speed limitation Dry running protection Minimum flow stop Characteristic curve control (Qmin, Qmax) Open-loop control Open-loop operation via specified setpoint User-definable speed (0 to 70 Hz) Stand-by mode (stop at minimum speed after a defined period of time) Programmable start and stop ramps Slave in multiple pump configuration with up to 6 pumps Master in multiple pump configuration with up to 6 pumps Parameterisable H/Q/P curves Closed-loop control Closed-loop operation via integrated, programmable PI controller Differential pressure control Level control Temperature control Flow control Dynamic pressure setpoint compensation Commissioning Plug & run Automatic sensor recognition (when frequency inverter is started) Operation 3 LEDs (OK, warning and alert) Control panel (optional), rotatable 180_ Control panel, rotatable 180_ Monitoring Fault history Energy meter (kWh) Operating hours counter (motor, FI) Energy savings meter (kWh) Communication Profibus field bus system LON field bus system RS 232 service interface Installation CM: in control cabinet IP 21 MM: with adapter on motor, IP 55 WM: wall-mounted IP 55 Functional enhancements (planned) Sensorless flow rate estimation Sensorless closed-loop control H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H (i2t control) H H H H H H H H H

PumpDrive ... Advanced

Movitec A Casing
Pump casing with suction and discharge nozzles of identical nominal diameters arranged opposite to each other (in-line design). Movitec V(S): Pump casing made of stainless steel, baseplate made of powder-coated grey cast iron. Movitec LHS: stainless steel pump casing.

Installation
Vertical installation (horizontal installation see page 5)

Coating

Shaft seal
Uncooled, maintenance-free mechanical seal to EN 12756

Movitec V(S): Powder-coated grey cast iron motor stool and baseplate. Movitec V(S): Grey cast iron sliding flanges protected by sherardising. All pumps: Stainless steel parts without additional protective coating.

Drive

Tests/Inspections
Standard: Pressure test to EN 809 Leak test with water

Motor without speed control Standard for V(S) and LHS: -- Electric motor, 50 Hz, air-cooled, 2-pole and 4-pole, standard KSB motor with main dimensions to IEC. Other motor makes after prior consultation with KSB, up to 2.2 kW 220--240 V/380--420 V, from 3 kW 380--420 V/660--725 V, enclosure IP 55, thermal class F, up to 4 kW in V18 type of construction; from 5.5 kW in V1 type of construction, all motors >3 kW with PTC thermistors. Approved variants: -- Explosion-proof motor II 2 G Eexd/Eexe T3/T4, type of construction V1/V18, make to KSBs choice. -- Motor for mains voltage 500 V, type of construction V1/V18, make to KSBs choice. -- Motor make to customers choice (upon request). -- PTC thermistors for motors < 3 kW Direction of rotation: Clockwise, viewed from the drive end (see rotation arrow on motor stool). Coupling: -- All sizes: rigid coupling -- The couplings comply with the EC Machinery Directive. Motor with speed control system Standard for V(S) and LHS: -- Electric motor, 50 Hz, air-cooled, 2-pole and 4-pole, KSB standard motor with main dimensions to IEC. Other motor makes after prior consultation with KSB, 3~380 V AC --15 % to 480 V AC +10 % Enclosure IP 55, thermal class F, up to 4 kW in V18 type of construction; from 5.5 kW in V1 type of construction, all motors >3 kW with PTC thermistors. Approved variants: -- Motor make to customers choice (upon request). -- PTC thermistors for motors < 3 kW Direction of rotation: Clockwise, viewed from the drive end (see rotation arrow on motor stool). Coupling -- All sizes: rigid coupling -- The couplings comply with the EC Machinery Directive.

Possible variant (on request): Hydraulic test evidenced by test report. This test is always carried out using the original motor. The NPSH and the suction head are not measured. Materials testing Certificate of compliance with the order (corresponds to EN 10 204) In the certificate of compliance with the order the manufacturing or processing works confirms by way of an informal report without specifying test results that the delivery complies with the stipulations of the purchase order (certificate to 2.2 and 3.1 available upon request).

Characteristic curves 2)
The characteristic curves are based on the following principles: F Tolerances to ISO 9906 Class 2/Annex A F Measurements are made with standardised KSB motors with integrated frequency inverters 1) F The characteristic curves were obtained with deaerated water at a temperature of 20 C and a density of 1.0 kg/dm3 1) F The characteristic curves are valid for a kinematic viscosity of 1 mm2/s (1 cst) 1) F The pump is designed to give optimum performance at the point of best efficiency (Qopt). This means: F Recommended operating range: 0.50 to 1.30 of Qopt 2) F The characteristic curve outside this range is given for information purposes only 2). F A minimum flow must be maintained to prevent the pump from overheating. Movitec V 24 32 45 65 LHS 6
1) 2)

Qmin in m3/h 2.2 4.0 4.6 6.1 0.8

In case of different parameters, the performance data must be corrected accordingly. See example on the following page

Movitec A
The following curve shows the minimum flow, corresponding to a percentage of the optimum flow Qopt (flow rate at best efficiency point), as a function of the temperature of the fluid handled. Minimum flow
30 25 20 15 10 5 0 40 50 60 70 80 90 100 110 120

Q min [%]

F NPSH The NPSH values given in the individual characteristic curves are minimum values which correspond to the cavitation limit. They refer to deaerated water. A safety allowance of at least 0.5 m must be added when selecting the pump to compensate for measuring inaccuracies and minor manufacturing deviations. The NPSH curve reflects mean values.

Temperature [C] F Maximum pressure at the discharge nozzle: 25 bar -- shut-off head with round flange (VF) and Victaulic coupling (VSV). 40 bar -- shut-off head with round flange (LHS).

Selection example for pump set without speed control

Number of stages Motor size

18 7,5 kW

Qmin

NPSH required. A safety allowance of 0.5 m must be added to the NPSH value of the characteristic curve when selecting the system.

Power input per stage at a density = 1 kg/dm3

10

Movitec A Example: Differential pressure control

Control task: Maintaining the differential supply pressure even with changing operating conditions and interferences.

Pump discharge pressure %

Pump shaft power %

Power saving

1217:31

Pump flow rate %

Full load

Pump flow rate %

1217:32

Full load

opt : optimum pump efficiency curve


1

Pump curve for fixed-speed operation (n = 100 %)

Pump curve for variable-speed operation (n = variable)

11

Movitec A Pump performance


A pumps performance is described by several characteristic curves combined in a performance chart, which correspond to the different frequencies (Hz) or motor speeds. The motor speed is indicated for each characteristic curve. The range covered by the H/Q curves and the power input curves extends from the minimum speed stipulated for the pump up to the maximum speed. Any duty point within this performance range can be obtained by adjusting the rotational speed accordingly. Speed range: 100 -- 25 % or 50 -- 12.5 Hz.

Performance chart

Change in operating data


Flow rate Q, pump head H and power input P change as a function of speed N or frequency F.

A pumps NPSH changes depending on the respective H/Q curve. However, the NPSH of the pump at maximum speed (or maximum frequency) must always be taken into account and used as calculation basis.

PumpDrive
Standard functions: -- Diagnostic LEDs signal operation, overload or fault -- Increased starting torque -- Pump-specific 1) minimum and maximum speeds -- Two isolated analog inputs for standard signals / live-zero yes/no 1) -- Automatic restart after automatic safety tripping yes / no1) -- Three restarting attempts within 3 seconds each 1) -- Modes of operation: open-loop control/differential pressure control by integrated PI controller with automatic detection -- Direction of rotation: anti-clockwise/clockwise 1) -- External standard signal 0/2 -- 10 V / 0/4 -- 20 mA -- General fault message contact (240 V AC, max. 1 A) -- Pump is stopped when flow rate falls below a minimum value -- Setpoint specified via motor potentiometer function
1)

Protective functions: -- Electronic overcurrent trip -- Integrated EMC (electromagnetic compatibility) filter, class B <7.5 kW, class A >11 kW -- Automatic overload control -- Thermal overload control -- Full motor protection by PTC thermistors -- Undervoltage/overvoltage protection -- Phase short-circuit protection -- Earth fault current protection -- Dry running protection -- Start/Stop via digital input -- No motor protection or mains switch required For details please refer to type series booklet PumpDrive 4070.5-10

With optional control panel

12

Movitec A Recommended spare parts stock for two years continuous operation
Number of pumps of identical size (including stand-by pumps) Part No. Description 10-5 Stage casing, cpl. with bearing kit Stage casing with bearing (108.02) + bearing sleeve (529) + impeller (230) + spacer sleeve, short (525.01) 1 Mechanical seal 433 2 O-rings 412.01 2 Gaskets (oval) 400 (for pumps with V flange variant only) 1 O-ring 412.05 (for cartridge seal only) 1 O-ring 412.06 (for cartridge seal only) 1 set --> 2 3 4 5 6 and 7 8 and 9 10 and more % 3 sets 30

Quantity of spare parts 2 sets

433

1 set

2 sets

3 sets

30

13

Movitec A List of fluids handled


The data refer to the chemical resistance of the materials. The relevant regulations/standards governing individual pump applications have to be complied with. The actual operating conditions must always be checked (concentration, temperature, solids content). The penetration of air into the system must be avoided by all means. If the operating conditions differ from the data given (e.g. mixed products) or if the fluids are not included in the table below, please contact KSB. Basic data: -- Temperature ranges: D Reference temperature: 20 C. D In the case of temperatures <0 C Contact KSB. D In the case of temperatures > 50 C: check and observe the vapour pressure of the fluid handled! D Max. temperature = 120 C, unless indicated otherwise. -- Max. concentration = 100 % unless indicated otherwise. -- Mechanical seal of silicon carbide / carbon (Q1B): not suitable for fluids containing solids. This rule also covers particles developing as a result of salt crystallisation at low fluid temperatures. -- Mechanical seal of tungsten carbide / tungsten carbide (U3U3): max. solids content 20 ppm (depending on particle size), with the exception of corrosive fluids. Fluids with a higher solids content are not permitted (ppm = 1 mg/kg). -- Please note: High temperatures will increase corrosion (reference temperature = 20 C). -- Under unfavourable conditions (high temperatures, deposits, long idle periods), chloride contents of more than 300 mg/l may result in localised corrosion.
Fluid handled (see special conditions given at the end of the table) Alcohol (ethanol) Alkaline solution (bottle rinsing) (pH <9.5) Alkaline solution (metal degreasing) (pH <9.5) Alum Aluminium sulphate Ammonium bicarbonate Ammonium chloride (salmiac) Ammonium sulphate Antifreeze (glycol base, salt-free) Antifreeze (halogen-free) 4) Buttermilk Butyl alcohol (Butanol) Calcium acetate Calcium nitrate (non acidic) Cider Citric acid Copper sulphate Crude oil 4) Crude oil condensate 4) Deionised water (fully desalinated) Diesel oil (light, extra light) Ethanol (alcohol) Ethylene glycol / Diethylene glycol (salt-free) Ferric sulphate (II) Fruit juices, pH-neutral (6.5) Fuel oil (light) (without antifreeze for --20 _C and below) Glycerine Glycol (salt-free) (see ethylene glycol) Hexane Isopropyl alcohol (2-propanol) Kerosene (jet fuel) 10 10 10 25 10 Max. content in %
Max. tempera- Mechanical seal variant ture in C 13 14 15

16 ----V 1) --------V 1) ---------V --------

17 ---LHS ----LHS -LHS ---LHS --LHS LHS -LHS -LHS -LHS LHS LHS LHS LHS -LHS

19 LHS ----LHS LHS LHS LHS LHS LHS LHS LHS -LHS ----LHS -LHS LHS ---LHS LHS -LHS --

10 10 3 5 10 25 20 min. 20

60 80 80 80 60 40 30 60

V ----V1) VS V1) V V V1) V VS -V1) ----V1) -V V ---V V -V --

---VS -----------V 1) -V 1) V 1) -V ---V V --V -V

-V 1) V 1) -------------V 1) ---------------

80 60 60 60 40 30 80 80

80 60 100 80 60 80 40 100 40 80 100

1)

Only valid if all standard (brass) screw plugs of Movitec V are replaced by stainless steel screw plugs. Otherwise, a Movitec VS with the right seal must be used. 4) Fluid details required.

14

Movitec A
Fluid handled (see special conditions given at the end of the table) Lactic acid Liqueur Magnesium sulphate Maleic acid Miscella 4) Oil-water mixtures (without solids) Oils (without abrasive solids): Corn oil Cutting oil 4) Hydraulic oil 4) Linseed oil Linseed oil + 3 % H2SO4 Lubricating oil 4) Mineral oil 4) Peanut oil Rapeseed oil Salad oil 4) Silicone oil 4) Soybean oil Turpentine oil 4) Turbine oil (no SDF oils)4) Vegetable oils (H2SO4-free) 4) Paraffin(s) 4) Petroleum (without solids) Phosphoric acid Polyethylene glycol 4) Polyglycols 4) Potassium bicarbonate Potassium carbonate Potassium hydroxide Potassium nitrate Potassium sulphate Propyl alcohol (see isopropyl alcohol) Soda lye (see sodium hydroxide) Sodium carbonate Sodium hydroxide (soda lye) Sodium nitrate (non acidic) Sodium sulphate (non acidic) Spirits Sulphuric acid Tannic acid Tartaric acid Trisodium phosphate Turpentine (oil) (see oil, turpentine) 4) Vinegar (wine vinegar) 100 100 80 60 60 100 80 100 100 60 100 60 100 Max. content in % 40 10 10
Max. tempera- Mechanical seal variant ture in C 13 14 15

16 -------V 3) -------------------------------------

17 LHS LHS LHS -LHS LHS LHS -LHS LHS -LHS LHS LHS LHS LHS LHS LHS LHS LHS LHS LHS LHS -LHS LHS ----LHS --------LHS LHS -LHS --

19 ------------------------LHS --------LHS -LHS LHS LHS -----LHS

60 60 80 60 60

------------------------V --------V1) -V1) V1) V -----VS

V 1) V V VS V 1) V V1)3) -V 3) V 3) VS V 3) V 3) V 3) V 3) V 3) V 3) V 1)3) V 3) V 3) V 3) V V V -V ----VS -------VS 3) V 1) V 1) -V --

--------------------------V 1) V 1) V 1) V 1) ----V 1) ------V 1) ---

10 25 5 10 3

80 20 80 80 60 60 60 30 20 80 60 60 60 60 60 30 80 60 80 60 60

6 10 10 5 5 20 8 4 10

1)

Only valid if all standard (brass) screw plugs of Movitec V are replaced by stainless steel screw plugs. Otherwise, a Movitec VS with the right seal must be used. 3) Pure fluid without abrasive solids. 4) Fluid details required.

15

Movitec A
Fluid handled (see special conditions given at the end of the table) Water-glycol mixture (salt-free, with inhibitors) Water: Condensate Cooling water Decarbonised water Deionised water Distilled water Drinking water Fire-fighting water Fully desalinated water (see deionised water) Heating water Partly desalinated water (see decarbonised Pure water (chemically neutral, no ultrapure water) Rinsing water Seawater (continuous operation) Softened water (see decarbonised water) Swimming pool water (no brine) Untreated water (suspended solids content < 20 ppm) Tap water Wine (white, red)
1)

Max. content in % min. 20

Max. tempera- Mechanical seal variant ture in C 13 14 15

16 --V 1) ---------V 1) VS ------

17 ---------------LHS --LHS

19 LHS LHS --LHS LHS LHS --LHS -LHS -----LHS LHS

V VS 2) --V1) V1) V --V -V1) 25 -----V V1)

---------------VS ----

---V 1) ---V 1) --------V ---

water)

40

Only valid if all standard (brass) screw plugs of Movitec V are replaced by stainless steel screw plugs. Otherwise, a Movitec VS with the right seal must be used. 2) Water treatment shall be in accordance with VdTV guidelines for feed and boiler water in steam systems of up to 64 bar. The penetration of air into the system must be avoided by all means.

16

Movitec A Movitec V with KSB standard motor, fixed/variable-speed 1) 3~230/400 V up to 2.2 kW, 3 kW and above: 3~400/692 V
Size
Number of stages

Shaft seal code

Motor rating kW

Pump Drive 1) Type ..001K10.. ..001K10.. ..001K50.. ..002K20.. ..002K20.. ..004K00.. ..004K00.. ..004K00.. ..004K00.. ..005K50.. ..005K50.. ..005K50.. ..007K50.. ..002K20.. ..004K00.. ..005K50.. ..007K50.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..018K50.. ..018K50.. ..022K00.. ..002K20.. ..004K00.. ..005K50.. ..007K50.. ..011K00.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..018K50.. ..022K00.. ..022K00.. ..030K00.. ..030K00.. ..030K00.. ..030K00.. ..037K00.. ..037K00.. ..037K00.. ..004K00.. ..005K50.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..022K00..

Max. current Oval flange Movitec V Fixed-speed Fixed-speed pump pump Imax in A Ident. No. kg 5.2 5.2 7.1 9.0 9.0 8.1 8.1 9.9 9.9 12.0 12.0 12.0 16.0 10.4 9.0 12.0 15.5 30.5 30.5 31.7 31.7 40.5 40.5 40.5 44.5 10.4 9.0 12.0 15.5 30.5 30.5 30.5 31.7 31.7 40.5 40.5 44.5 44.5 56.1 56.1 56.1 56.1 65.5 65.5 65.5 7.0 12.0 30.5 30.5 31.7 31.7 40.5 44.5 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 3.0 3.0 4.1 5.2 5.2 4.7 4.7 5.7 5.7 6.9 6.9 6.9 9.2 6.0 5.2 6.9 8.9 17.6 17.6 18.3 18.3 23.4 23.4 23.4 25.7 6.0 5.2 6.9 8.9 17.6 17.6 17.6 18.3 18.3 23.4 23.4 25.7 25.7 32.4 32.4 32.4 32.4 37.8 37.8 37.8 4.1 6.9 17.6 17.6 18.3 18.3 23.4 25.7 -----------------------------------------------------------------------------------------------------------

Round flange Movitec VF Fixed-speed pump Ident. No. 47 110 071 47 110 072 47 110 073 47 110 074 47 110 075 47 110 076 47 110 077 47 110 078 47 110 079 47 110 080 47 110 081 47 110 082 47 110 083 47 110 108 47 110 109 47 110 110 47 110 111 47 110 112 47 110 113 47 110 114 47 110 115 48 894 051 47 110 117 47 110 118 47 110 119 47 110 140 47 110 141 47 110 142 47 110 143 47 110 144 47 110 145 47 110 146 47 110 147 47 110 148 47 110 149 47 110 150 47 110 151 47 110 152 47 110 153 47 110 154 47 110 155 47 110 156 47 110 157 47 110 158 47 110 159 47 110 176 47 110 177 48 894 061 47 110 179 47 110 180 47 110 181 47 110 182 47 110 183 kg 57.8 60.1 64.5 73.8 76.2 82.5 84.9 94.2 96.6 115.5 117.8 120.2 138.1 60.9 81.1 89.5 95.8 167.1 169.4 185.7 188.0 205.0 207.5 209.8 247.9 61.9 80.0 88.3 92.4 163.7 163.8 166.1 180.1 182.5 197.5 199.9 235.8 238.1 362.2 364.5 364.6 366.9 367.0 369.3 369.4 78.1 96.5 170.0 173.5 190.9 194.3 212.7 252.1

Victaulic coupling Movitec VV Fixed-speed pump Ident. No. -----------------------------------------------------kg ------------------------------------------------------

4-pole
Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 1 2 3 4 5 6 7 8 9 10 11 12 16 1 2 3 4 5 6 7 8 9 10 11 12 1--1 1 2--1 2 3--1 3 4--1 4 5--1 5 6--1 6 7--1 7 8--1 8 9--1 9 10--1 10 1 2 3 4 5 6 7 8 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 1.1 1.1 1.5 2.2 2.2 3 3 4 4 5.5 5.5 5.5 7.5 2.2 4 5.5 7.5 11 11 15 15 18.5 18.5 18.5 22 2.2 4 5.5 7.5 11 11 11 15 15 18.5 18.5 22 22 30 30 30 30 37 37 37 3 5.5 11 11 15 15 18.5 22

2-pole
Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 65 Movitec V 65 Movitec V 65 Movitec V 65 Movitec V 65 Movitec V 65 Movitec V 65 Movitec V 65
1)

Voltage for variable-speed motors generally 3~400 V, currents see type series booklet 4070.5-10

17

Movitec A Movitec V with KSB standard motor, fixed/variable-speed 1) 3 kW and above: 3~230/400 V
Size
Number of stages

Shaft seal code

Motor rating kW

Pump Drive 1) Type ..004K00.. ..004K00.. ..004K00.. ..004K00.. ..005K50.. ..005K50.. ..005K50.. ..007K50.. ..004K00.. ..005K50.. ..007K50.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..018K50.. ..018K50.. ..022K00.. ..004K00.. ..005K50.. ..007K50.. ..011K00.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..018K50.. ..022K00.. ..022K00.. ..003K00.. ..005K50.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..022K00.. ..030K00..

Max. current Oval flange Movitec V Fixed-speed Fixed-speed pump pump Imax in A Ident. No. kg 14.0 14.0 17.2 17.2 20.8 20.8 20.8 27.7 15.6 20.8 26.8 52.8 52.8 54.9 54.9 54.9 70.1 70.1 77.1 15.6 20.8 26.8 52.8 52.8 52.8 54.9 54.9 70.1 70.1 77.1 77.1 12.1 20.8 52.8 52.8 54.9 54.9 70.1 77.1 77.1 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 8.1 8.1 9.9 9.9 12.0 12.0 12.0 16.0 9.0 12.0 15.5 30.5 30.5 31.7 31.7 31.7 40.5 40.5 44.5 9.0 12.0 15.5 30.5 30.5 30.5 31.7 31.7 40.5 40.5 44.5 44.5 7.0 12.0 30.5 30.5 31.7 31.7 40.5 44.5 44.5 ---------------------------------------------------------------------------------

Round flange Movitec VF Fixed-speed pump Ident. No. 47 110 063 47 110 064 47 110 065 47 110 066 47 110 067 47 110 068 47 110 069 47 110 070 47 110 097 47 110 098 47 110 099 47 110 100 47 110 101 47 110 102 47 110 103 48 894 050 47 110 105 47 110 106 47 110 107 47 110 128 47 110 129 47 110 130 47 110 131 47 110 132 47 110 133 47 110 134 47 110 135 47 110 136 47 110 137 47 110 138 47 110 139 47 110 167 47 110 168 48 894 060 47 110 170 47 110 171 47 110 172 47 110 173 47 110 174 48 894 072 kg 82.5 84.9 94.2 96.6 115.5 117.8 120.2 138.1 81.1 89.5 95.8 167.1 169.4 185.7 188.0 205.0 207.5 209.8 247.9 80.0 88.3 92.4 163.7 163.8 166.1 180.1 182.5 197.5 199.9 235.8 238.1 78.1 96.5 170.0 173.5 190.9 194.3 212.7 252.1 329.0

Victaulic coupling Movitec VV Fixed-speed pump Ident. No. ----------------------------------------kg -----------------------------------------

4-pole
Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 Movitec V 24 6 7 8 9 10 11 12 16 2 3 4 5 6 7 8 9 10 11 12 1 2--1 2 3--1 3 4--1 4 5--1 5 6--1 6 7--1 1 2 3 4 5 6 7 8 9 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 3 3 4 4 5.5 5.5 5.5 7.5 4 5.5 7.5 11 11 15 15 18.5 18.5 18.5 22 4 5.5 7.5 11 11 11 15 15 18.5 18.5 22 22 3 5.5 11 11 15 15 18.5 22 30

2-pole
Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 32 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 45 Movitec V 65 Movitec V 65 Movitec V 65 Movitec V 65 Movitec V 65 Movitec V 65 Movitec V 65 Movitec V 65 Movitec V 65

*) Available as variant (Factory Option) 1) Voltage for variable--speed motors generally 3~400 V, currents see type series booklet 4070.5-10

18

Movitec A Movitec VS with KSB standard motor, fixed/variable-speed 1) 3~230/400 V up to 2.2 kW, 3 kW and above: 3~400/692 V
Size
Number of stages

Shaft seal code

Motor rating kW

Pump Drive 1) Type ..001K10.. ..001K10.. ..001K50.. ..002K20.. ..002K20.. ..004K00.. ..004K00.. ..004K00.. ..004K00.. ..005K50.. ..005K50.. ..005K50.. ..007K50.. ..002K20.. ..004K00.. ..005K50.. ..007K50.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..018K50.. ..018K50.. ..022K00.. ..002K20.. ..004K00.. ..005K50.. ..007K50.. ..011K00.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..018K50.. ..022K00.. ..022K00.. ..030K00.. ..030K00.. ..030K00.. ..030K00.. ..037K00.. ..037K00.. ..037K00.. ..004K00.. ..005K50.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..022K00.. ..030K00..

Max. current Oval flange Movitec VS Fixed-speed Fixed-speed pump pump Imax in A Ident. No. kg 5.2 5.2 7.1 9.0 9.0 8.1 8.1 9.9 9.9 12.0 12.0 12.0 16.0 10.4 9.0 12.0 15.5 30.5 30.5 31.7 31.7 40.5 40.5 40.5 44.5 10.4 9.0 12.0 15.5 30.5 30.5 30.5 31.7 31.7 40.5 40.5 44.5 44.5 56.1 56.1 56.1 56.1 65.5 65.5 65.5 7.0 12.0 30.5 30.5 31.7 31.7 40.5 44.5 56.1 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 3.0 3.0 4.1 5.2 5.2 4.7 4.7 5.7 5.7 6.9 6.9 6.9 9.2 6.0 5.2 6.9 8.9 17.6 17.6 18.3 18.3 23.4 23.4 23.4 25.7 6.0 5.2 6.9 8.9 17.6 17.6 17.6 18.3 18.3 23.4 23.4 25.7 25.7 32.4 32.4 32.4 32.4 37.8 37.8 37.8 4.1 6.9 17.6 17.6 18.3 18.3 23.4 25.7 32.4 -------------------------------------------------------------------------------------------------------------

Round flange Movitec VSF Fixed-speed pump Ident. No. 47 110 637 47 110 638 47 110 639 47 110 640 47 110 641 47 110 642 47 110 643 47 110 644 47 110 645 47 110 646 47 110 647 47 110 648 47 110 649 47 110 674 47 110 675 47 110 676 47 110 677 47 110 678 47 110 679 47 110 680 47 110 681 48 894 053 47 110 683 47 110 684 47 110 685 47 110 705 47 110 706 47 110 707 47 110 708 47 110 709 47 110 710 47 110 711 47 110 712 47 110 713 47 110 714 47 110 715 47 110 716 47 110 717 47 110 718 47 110 719 47 110 720 47 110 721 47 110 722 47 110 723 47 110 724 47 110 741 47 110 742 48 894 063 47 110 744 47 110 745 47 110 746 47 110 747 47 110 748 47 110 749 kg 57.8 60.1 64.5 73.8 76.2 82.5 84.9 94.2 96.6 115.5 117.8 120.2 138.1 60.9 81.1 89.5 95.8 167.1 169.4 185.7 188.0 205.0 207.5 209.8 247.9 61.9 80.0 88.3 92.4 163.7 163.8 166.1 180.1 182.5 197.5 199.9 235.8 238.1 362.2 364.5 364.6 366.9 367.0 369.3 369.4 78.1 96.5 170.0 173.5 190.9 194.3 212.7 252.1 255.5

Victaulic coupling Movitec VSV Fixed-speed pump Ident. No. ------------------------------------------------------kg -------------------------------------------------------

4-pole
Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 1 2 3 4 5 6 7 8 9 10 11 12 16 1 2 3 4 5 6 7 8 9 10 11 12 1--1 1 2--1 2 3--1 3 4--1 4 5--1 5 6--1 6 7--1 7 8--1 8 9--1 9 10--1 10 1 2 3 4 5 6 7 8 9 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 1.1 1.1 1.5 2.2 2.2 3 3 4 4 5.5 5.5 5.5 7.5 2.2 4 5.5 7.5 11 11 15 15 18.5 18.5 18.5 22 2.2 4 5.5 7.5 11 11 11 15 15 18.5 18.5 22 22 30 30 30 30 37 37 37 3 5.5 11 11 15 15 18.5 22 30

2-pole
Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 65 Movitec VS 65 Movitec VS 65 Movitec VS 65 Movitec VS 65 Movitec VS 65 Movitec VS 65 Movitec VS 65 Movitec VS 65
1)

Voltage for variable-speed motors generally 3~400 V, currents see type series booklet 4070.5-10

19

Movitec A Movitec VS with KSB standard motor, fixed/variable-speed 1) 3 kW and above: 3~230/400 V
Size
Number of stages

Shaft seal code

Motor rating kW

Pump Drive 1) Type ..004K00.. ..004K00.. ..004K00.. ..004K00.. ..005K50.. ..005K50.. ..005K50.. ..007K50.. ..004K00.. ..005K50.. ..007K50.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..018K50.. ..018K50.. ..022K00.. ..004K00.. ..005K50.. ..007K50.. ..011K00.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..018K50.. ..022K00.. ..022K00.. ..003K00.. ..005K50.. ..011K00.. ..011K00.. ..015K00.. ..015K00.. ..018K50.. ..022K00..

4-pole
Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 Movitec VS 24 6 7 8 9 10 11 12 16 2 3 4 5 6 7 8 9 10 11 12 1 2--1 2 3--1 3 4--1 4 5--1 5 6--1 6 7--1 1 2 3 4 5 6 7 8 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 3 3 4 4 5.5 5.5 5.5 7.5 4 5.5 7.5 11 11 15 15 18.5 18.5 18.5 22 4 5.5 7.5 11 11 11 15 15 18.5 18.5 22 22 3 5.5 11 11 15 15 18.5 22

Max. current Oval flange Movitec VS Fixed-speed Fixed-speed pump pump Imax in A Ident. No. kg 14.0 14.0 17.2 17.2 20.8 20.8 20.8 27.7 15.6 20.8 26.8 52.8 52.8 54.9 54.9 70.1 70.1 70.1 77.1 15.6 20.8 26.8 52.8 52.8 52.8 54.9 54.9 70.1 70.1 77.1 77.1 12.1 20.8 52.8 52.8 54.9 54.9 70.1 77.1 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 8.1 8.1 9.9 9.9 12.0 12.0 12.0 16.0 9.0 12.0 15.5 30.5 30.5 31.7 31.7 40.5 40.5 40.5 44.5 9.0 12.0 15.5 30.5 30.5 30.5 31.7 31.7 40.5 40.5 44.5 44.5 7.0 12.0 30.5 30.5 31.7 31.7 40.5 44.5 -------------------------------------------------------------------------------

Round flange Movitec VSF Fixed-speed pump Ident. No. 47 110 629 47 110 630 47 110 631 47 110 632 47 110 633 47 110 634 47 110 635 47 110 636 47 110 663 47 110 664 47 110 665 47 110 666 47 110 667 47 110 668 47 110 669 48 894 052 47 110 671 47 110 672 47 110 673 47 110 693 47 110 694 47 110 695 47 110 696 47 110 697 47 110 698 47 110 699 47 110 700 47 110 701 47 110 702 47 110 703 47 110 704 47 110 732 47 110 733 48 894 062 47 110 735 47 110 736 47 110 737 47 110 738 47 110 739 kg 82.5 84.9 94.2 96.6 115.5 117.8 120.2 138.1 81.1 89.5 95.8 167.1 169.4 185.7 188.0 205.0 207.5 209.8 247.9 80.0 88.3 92.4 163.7 163.8 166.1 180.1 182.5 197.5 199.9 235.8 238.1 78.1 96.5 170.0 173.5 190.9 194.3 212.7 252.1

Victaulic coupling Movitec VSV Fixed-speed pump Ident. No. ---------------------------------------kg ----------------------------------------

2-pole
Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 32 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 45 Movitec VS 65 Movitec VS 65 Movitec VS 65 Movitec VS 65 Movitec VS 65 Movitec VS 65 Movitec VS 65 Movitec VS 65

*) Available as variant (Factory Option) 1) Voltage for variable-speed motors generally 3~400 V, currents see type series booklet 4070.5-10

20

Movitec A Movitec LHS with KSB standard motor, fixed/variable-speed 1) 3~400/692 V


Size Number of stages Shaft seal code Motor rating kW Pump Drive 1) Type ..005K50.. ..007K50.. ..011K00.. ..011K00.. ..011K00.. ..015K00.. Max. current Fixed-speed pump Imax in A 12.0 15.5 30.5 30.5 30.5 31.7 / / / / / / 6.9 8.9 17.6 17.6 17.6 18.3 Round flange Movitec LHS Fixed-speed pump Ident. No. 47 110 756 47 110 757 48 894 044 47 110 759 47 110 760 48 894 047 kg 92.1 99.1 166.0 171.2 174.2 191.0

2-pole
Movitec LHS 6 Movitec LHS 6 Movitec LHS 6 Movitec LHS 6 Movitec LHS 6 Movitec LHS 6 10 12 14 16 18 20 17 17 17 17 17 17 5.5 7.5 11 11 11 15

Movitec LHS with KSB standard motor, fixed/variable-speed 1) 3~230/400 V


Size Number of stages Shaft seal code Motor rating kW Pump Drive 1) Type ..015K00.. Max. current Fixed-speed pump Imax in A 54.9 / 31.7 Round flange Movitec LHS Fixed-speed pump Ident. No. 48 894 108 kg 191.0

2-pole
Movitec LHS 6
1)

20

17

15

Voltage for variable-speed motors generally 3~400 V, currents see type series booklet 4070.5-10

21

*) Qmin up to 40 _C, for temperatures >40 _C refer to the table on page 10 22

9 18,5 kW

*) Qmin up to 40 _C, for temperatures >40 _C refer to the table on page 10 23

*) Qmin up to 40 _C, for temperatures >40 _C refer to the table on page 10 24

9 30 kW

3 11 kW

*) Qmin up to 40 _C, for temperatures >40 _C refer to the table on page 10 25

20 15 kW

14 11 kW

*) Qmin up to 40 _C, for temperatures >40 _C refer to the table on page 10 26

Movitec A Dimensions tables Movitec VF 24 1450 1/min


VF 24
Stages PD
PumpDrive

E1 A A A A A B B B B B B B B 176 176 176 194 194 194 194 233 233 266 266 266 266

E2 136 136 136 147 147 147 147 162 162 179 179 179 179

E3 286 286 286 286 286 286 286 305 305 328 328 328 328

F1 738 786 835 919 968 1016 1065 1121 1170 1297 1346 1394 1626

F2 458 506 555 603 652 700 749 797 846 914 963 1011 1205

1 2 3 4 5 6 7 8 9 10 11 12 16

PumpDrive
Model

Dimensions A B 260 325 190 250

C 158 170

A B

Dimensions in mm (details see type series booklet PumpDrive 4070.5)

Flange variants Round flange PN 25 Movitec V(S) F

Position of terminal box for all pump sizes see page 31 27

Movitec A Dimensions tables Movitec VF 32 2900 1/min


VF 32
Stages PD

E1 A B B B C C C C C C C C 176 233 233 233 315 315 315 315 315 315 315 350

E2 136 162 162 162 206 206 206 206 206 206 206 225

E3 286 305 328 328 431 431 431 431 431 431 431 431

F1 733 830 904 980 1279 1327 1376 1424 1517 1565 1614 1711

F2 458 506 575 623 777 825 874 922 971 1019 1068 1116

1
PumpDrive

2 3 4 5 6 7 8 9 10 11 12

PumpDrive
Model

Dimensions A B 260 325 420 190 250 320

C 158 170 235

A B C

Dimensions in mm (details see type series booklet PumpDrive 4070.5)

Flange variants Round flange PN 25 Movitec V(S) F

Position of terminal box for all pump sizes see page 31 28

Movitec A Dimensions tables Movitec VF 45 2900 1/min


VF 45
Stages PD

E1 A B B B C C C C C C C C C D D D D D D D 176 233 233 233 315 315 315 315 315 315 315 350 350 398 398 398 398 398 398 398

E2 136 162 162 162 206 206 206 206 206 206 206 225 225 323 323 323 323 323 323 323

E3 286 305 328 328 431 431 431 431 431 431 431 431 431 518 518 518 518 518 518 518

F1 733 782 855 883 1182 1182 1230 1230 1279 1323 1371 1420 1469 1524 1572 1572 1621 1621 1669 1669

F2 458 458 526 526 680 680 728 728 777 777 825 825 874 874 922 922 971 971 1019 1019

1-1 1-1
PumpDrive

2-1 2-1 3-1 3-1 4-1 4-1 5-1 5-1 6-1 6-1 7-1 7-1 8-1 8-1 9-1 9-1 10-1 10-1

PumpDrive
Model

Dimensions A B 260 325 420 600 190 250 320 450

C 158 170 235 290

A B C D Flange variants Round flange PN 25 Movitec V(S) F

Dimensions in mm (details see type series booklet PumpDrive 4070.5)

Position of terminal box for all pump sizes see page 31 29

Movitec A Dimensions tables Movitec VF 65 2900 1/min


VF 65
Stages PD

Round flange PN 16 E1 B B B C C C C C C 194 233 233 315 315 315 315 350 350 E2 147 162 162 206 206 206 206 225 225 E3 286 328 328 431 431 431 431 431 431 F1 886 1008 1270 1389 1478 1567 1700 1838 1976 F2 570 679 768 887 976 1065 1154 1243 1332

1 2
PumpDrive

3 4 5 6 7 8 9

PumpDrive
Model

Dimensions A B 325 420 250 320

C 170 235

B C

Dimensions in mm (details see type series booklet PumpDrive 4070.5)

Flange variants Round flange PN 16

Position of terminal box for all pump sizes see page 31 30

Movitec A Dimensions tables Movitec LHS 6 2900 1/min


LHS 6
Stages PD

E1 233 233 233 315 315 315 Dimensions A B 325 420 250 320

E2 162 162 162 206 206 206

E3 328 328 328 431 431 431

F1 928 1015 1250 1310 1369 1429

F2 599 658 718 808 867 927

10 12
PumpDrive

B B B C C C

14 16 18 20

PumpDrive
Model

C 170 235

B C

Dimensions in mm (details see type series booklet PumpDrive 4070.5)

Position of terminal box for all sizes

Position of the terminal box (viewed from above)

Flange variants Round flange PN 40

Position 3 (Standard Movitec V, VS, LHS)

Position 9

Position 6

Position 12

31

Movitec A Sectional drawing


Movitec VF 24, 32, 45

20010712--E

32

Movitec A

Part No. Description 10-6 101 108.04 160 171.01 171.02 171.03 210 230 230.01 230.02 341 411.01 412.01 412.02 412.03 412.04 412.05 412.06 433 471 500 509.01 509.02 525.01 525.03 525.04 525.05 525.06 525.07 529 554.01 560 681 800 862 890 901.01 903.01 903.02 904 905 914.01 914.02 914.03 920.01 920.02 920.03 930 932 Pump shroud Pump casing Stage casing, bottom Cover Diffuser Diffuser with ceramic bearing Diffuser, upper Shaft Impeller (for Movitec VF 24 and 32) Impeller (for Movitec VF 45) Impeller, half-head (for Movitec VF 45) Motor stool Joint ring O-ring O-ring O-ring O-ring O-ring O-ring Mechanical seal Seal cover Ring, cartridge Intermediate ring Intermediate ring, upper Spacer sleeve, short Spacer sleeve, long Spacer sleeve, end Spacer sleeve, seal Spacer sleeve, seal extension Spacer sleeve, cartridge Bearing sleeve Washer Pin Coupling guard Motor (> 5.5 kW 801 flanged motor) Coupling shell Baseplate, cast Hexagon head bolt Screw plug Screw plug Grub screw Tie bolt Hexagon socket head cap screw Hexagon socket head cap screw Hexagon socket head cap screw Nut Impeller nut with non-metal insert Nut Safety device Circlip, (1/2)

Detail of cartridge seal

33

Movitec A Sectional drawing


Movitec VF 65

20000752--F

34

Movitec A

Part No. Description 10-6 101 160 171.01 171.02 210 230 341 411.01 412.01 412.02 412.04 412.05 412.06 433 471 500 509.01 509.02 509.03 525.01 525.02 525.03 525.04 525.05 525.07 529 550 554.01 554.04 560 681 722 801 862 890 901.01 901.04 903.01 903.02 904 905 914.01 914.02 914.03 920.01 920.02 920.03 920.05 930 932 Pump shroud Pump casing Cover Diffuser Diffuser with ceramic bearing Shaft Impeller Motor stool Joint ring O-ring O-ring O-ring O-ring O-ring Mechanical seal Seal cover Ring, cartridge Intermediate ring Intermediate ring, upper Intermediate ring, lower Spacer sleeve, short Spacer sleeve, middle Spacer sleeve, long Spacer sleeve, end Spacer sleeve, seal Spacer sleeve, cartridge Bearing sleeve Disc, lower Washer Washer Pin Coupling guard Taper piece, flanged Flanged motor Coupling shell Baseplate, cast Hexagon head bolt Hexagon head bolt Screw plug Screw plug Grub screw Tie bolt Hexagon socket head cap screw Hexagon socket head cap screw Hexagon socket head cap screw Nut Impeller nut with non-metal insert Nut Nut Safety device Circlip, (1/2)

35

Movitec A Sectional drawing


Movitec LHS 6

20030238--B

36

Movitec A

Part No. Description 10-6 101 108.01 108.02 108.04 108.05 210 230 341 411.01 411.04 412.01 412.03 433 525.01 525.02 525.03 525.04 525.05 529 554.01 554.02 554.04 560 681 722 801 862 901.01 901.02 901.04 903.01 903.02 905 914.01 920.01 920.02 920.03 920.05 930 932 Pump shroud Pump casing Stage casing Stage casing with ceramic bearing Stage casing, lower Stage casing, upper Shaft Impeller Motor stool Joint ring Joint ring O-ring O-ring Mechanical seal Spacer sleeve, short Spacer sleeve, middle Spacer sleeve, long Spacer sleeve, end Spacer sleeve, seal Bearing sleeve Washer Washer Washer Pin Coupling guard Taper piece, flanged Motor Coupling shell Hexagon head bolt Hexagon head bolt Hexagon head bolt Screw plug Screw plug Tie bolt Hexagon socket head cap screw Nut Impeller nut with non-metal insert Nut Nut Safety device Circlip 37

Movitec A

38

Movitec A

39

Movitec A

KSB Aktiengesellschaft 67225 Frankenthal Johann-Klein-Str. 9 67227 Frankenthal (Germany) Tel. +49 6233 86-0 Fax +49 6233 86-3401 www.ksb.com

1798.5/5-10

1.2.2011

Subject to technical modifications without prior notice.

Das könnte Ihnen auch gefallen