Sie sind auf Seite 1von 14

LINKSWITCH-MIB DEFINITIONS ::= BEGIN -----------This file describes the MIB supported by the 3Com FMS and MSH

LinkSwitch version 1.0. revision 05/23/94 08/19/94 08/22/94 history: Created. Add media sense and backup power supply ojbects. Add lsfddiPATHRingLatency object.

The LinkSwitch supports the standard "transmissions" MIB for FDDI and IEEE 802.3 interfaces, the proposed standard "dot3" MIB for the Ethernet interfaces, and the standard SMT/FDDI MIB for FDDI.

-- When an object's DESCRIPTION field includes the keyword DURABLE, -- the object's value is retained across system reinitialization. -- This MIB module uses the extended OBJECT-TYPE macro. IMPORTS a3Com FROM A3Com-products-MIB Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString, PhysAddress FROM RFC1213-MIB; -- a3Com linkSwitch OBJECT IDENTIFIER ::= { enterprises 43 } OBJECT IDENTIFIER ::= { a3Com 17 }

lsSRFilterEnable OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When false, the Address Filter forwards frames, that is, frames with a 1 in the Address. When true, the Address Filter Source Routed frames. Default value is ::= { linkSwitch 1 }

Source Routed MSB of the Source does not forward false. DURABLE."

lsSegmentFilterEnable OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls action taken with Eth frames with source and destination stations on the same segment (i.e. port). When true, the Address Filter will not forward intra-segment frames. When false, all frames received are forwarded. Default is true. DURABLE." ::= { linkSwitch 2 } lsMcastFilterEnable OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When false, all frames with a Multicast Destination Address that does not match any Address Filter entry are forwarded

to all ports. Those with a match are forwarded to port. When true, only frames with a Multicast Destination Address with a match in the Address Filter are forwarded to port. Default is false. DURABLE." ::= { linkSwitch 3 } lsLoopDetectAction OBJECT-TYPE SYNTAX INTEGER { shutport(1), -- shut down first port dup detected on shuteths(2), -- disable all ports, FDDI left up shutunit(3), -- shutdown the all media interfaces no-action(4) -- none of the preceding } ACCESS read-write STATUS mandatory DESCRIPTION "If a station appears to be on two ports, Address Filter thrashing will occur. Detection of this situation is possible, and this object controls the action to be taken when the situation is detected. Default is shutport. no-action means that no action will be taken, but this means Ethernet and FDDI networks will be flooded. NOTE: control of traps indicating the condition is not affected. DURABLE." ::= { linkSwitch 4 } lsAddressAgingTimer OBJECT-TYPE SYNTAX Counter ACCESS read-write STATUS mandatory DESCRIPTION "A count of the seconds that will elapse before the Address Filter contents are 'aged' to remove entries which are not active. Default is 1800, or 30 minutes. Write 0 to stop aging process from occuring. DURABLE." ::= { linkSwitch 5 } lsIPEchoAgingHelp OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If true, an IP echo frame will be broadcast on the subnet, which will cause otherwise quiecient stations to become active. The rate is half of lsAddressAgingTimer. DURABLE." ::= { linkSwitch 6 } lsProdVerSW OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS mandatory DESCRIPTION "This describes the version of the software currently running. Returns a string in the form X.YZ, where X represents the major version, Y represents the minor version or revision, and Z represents the development level of the revision." ::= { linkSwitch 7 } lsProdVerHW OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only

STATUS mandatory DESCRIPTION "This describes the version of the hardware currently running. Returns a string in the form X.YZ, where X represents the major version, Y represents the minor version or revision, and Z represents the development level of the revision." ::= { linkSwitch 8 } lsLEDstate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (80)) ACCESS read-only STATUS mandatory DESCRIPTION "A binary structure which describes the current state of all of the LEDs of an LinkSwitch. Actual layout available on request." ::= { linkSwitch 9 } lsTestResult OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When a test is initiated via lsAction, the result of the test is stored in this variable when the test has completed or failed. The value varies by test, is set to one (other) at the start of the test." ::= { linkSwitch 10 } lsAction OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following age-addr-table(2), -- remove old entries for all ports clear-addr-table(3), -- clear table for all ports disconnect-FDDI(4), -- shut down the FDDI side connect-FDDI(5), -- start up the FDDI side disconnect-Eth(6), -- shut down the Eth side connect-Eth(7), -- start up the Eth side test-fddipath(8), -- run a path test on the FDDI side test-ethports(9), -- test all ports on the ETH side test-lsfunc(10), -- test the FDDI and ETH together test-addr-filter(11) -- test the Address Filtering Logic } ACCESS read-write STATUS mandatory DESCRIPTION "Value when read will be other. Writing a value to this object will result in the associated action taking place. Note that it is possible to disconnect the management station from the LinkSwitch by issuing the disconnect-FDDI or disconnect-Eth acti ons, depending of course where the management station is connected to the LinkSwitch. For those actions which are tests, the resul t is in lsTestResult. If the action is disconnect-FDDI, the FDDI ring will function internally for inter-segment frames." ::= { linkSwitch 11 } lsEportNumber OBJECT-TYPE SYNTAX INTEGER

ACCESS read-only STATUS mandatory DESCRIPTION "A count of the Ethernet Ports supported by this system." ::= { linkSwitch 12 } lsEportTable OBJECT-TYPE SYNTAX SEQUENCE OF LsEportEntry ACCESS not-accessible STATUS mandatory ::= { linkSwitch 13 } lsEportEntry OBJECT-TYPE SYNTAX LsEportEntry ACCESS not-accessible STATUS mandatory INDEX { lsEportIndex } ::= { lsEportTable 1 } LsEportEntry ::= SEQUENCE { lsEportIndex lsEportEnable lsEportActivate lsEportLinkState lsEportName lsEportSQETestEnable lsEportLongPktsEnable lsEportMCastFilterEnable lsEportMCastRate lsEportMCastBurstLimit lsEportStationsNumber lsEportSecsSinceLastClear lsEportTestResult lsEportAction lsEportFtoEByteCts lsEportEtoFByteCts lsEportFtoEPacketCts lsEportEtoFPacketCts lsEportFtoEDropPktCts lsEportEtoFDropPktCts lsEportFtoEBusErrorCts lsEportEtoFBusErrorCts lsEportXMCastCts lsEportXBCastCts lsEportXDirectedCts lsEportXDeferredCts lsEportXLateCollCts lsEportXCollAbortCts lsEportXCSErrCts lsEportXExcessDeferCts lsEportXUnderrunCts lsEportXSQETestFailCts lsEportRMCastCts lsEportRBCastCts lsEportRDirectedCts lsEportRAlignmentCts lsEportRTooLongCts lsEportRFCSErrorCts lsEportROverrunCts

INTEGER, INTEGER, INTEGER, INTEGER, DisplayString, INTEGER, INTEGER, INTEGER, INTEGER, INTEGER, INTEGER, Counter, INTEGER, INTEGER, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter, Counter

} lsEportIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of this table entry." ::= { lsEportEntry 1 } lsEportEnable OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When false, port is in reset state, so no port (Ethernet) traffic will go through. When enabled, functionality is further controlled by lsEportActivate and ifOperStatus. Default is true. DURABLE." ::= { lsEportEntry 2 } lsEportActivate OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When true, port is shutdown but not reset, so counters will maintain values at time of deactivation. Further functionality controlled by ifOperStatus. Default is true." ::= { lsEportEntry 3 } lsEportLinkState OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), -- port completely disabled inactive(3), -- port enabled, no traffic through ready(4), -- port enabled, ready to accept link active(5), -- port enabled, traffic through shutdown(6) -- error or loop condition forced state } ACCESS read-only STATUS mandatory DESCRIPTION "Reports status of Link, as affected by lsEportEnable, lsEportActive, lsEportForwarding, and ifOperStatus." ::= { lsEportEntry 4 } lsEportName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..7)) ACCESS read-write STATUS mandatory DESCRIPTION "Abstract name for port. DURABLE." ::= { lsEportEntry 5 } lsEportSQETestEnable OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory

DESCRIPTION "When true, SQE test (heartbeat) will occur after each frame transmitted by Ethernet MAC. Need not be disabled for those ports which are connected to a repeater because Eth ports have a MAC. Default is true. DURABLE." ::= { lsEportEntry 6 } lsEportLongPktsEnable OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When true, frames with lengths longer than Ethernet maximum will be allowed to go from FDDI to Ethernet and Ethernet to FDDI. Default is false. DURABLE." ::= { lsEportEntry 7 } lsEportMCastFilterEnable OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When true, filtering will occur based on the values of lsEportMCastRate and lsEportMCastBurstLimit. If false, there is no port-level filtering performed on multicasts. Default is false. DURABLE." ::= { lsEportEntry 8 } lsEportMCastRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The rate in frames/second that multicasts will not be allowed to exceed, when lsEportBcastFilterEnable is true. Must also set lsEportMCastBurstLimit to non-zero value. DURABLE." ::= { lsEportEntry 9 } lsEportMCastBurstLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the maximum number of multicasts that can be forwarded from FDDI to Ethernet port in a 'burst' before the lsEportBCastRate limit causes frames to be discarded Must also set lsEportMCastBurstLimit to non-zero value. If this to zero, all multicasts are discarded. DURABLE." ::= { lsEportEntry 10 } lsEportStationsNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A count of stations whose Physical Address has been detected in the Source Address field of a frame which was transmitted by a station connected to this port." ::= { lsEportEntry 11 }

lsEportSecsSinceLastClear OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of seconds since last cleared counters for this port. Use lsEportAction to clear the counters." ::= { lsEportEntry 12 } lsEportTestResult OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "When a test is initiated via lsEportAction, the result of the test is stored in this variable when the test has completed or failed. The value varies by test, is set to one (other) at the start of the test." ::= { lsEportEntry 13 } lsEportAction OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following test-loopback(2), -- test all ports on the ETH side test-addrfilter(3), -- test the Address Filtering Logic zero-counters(4) -- zero all internal (hardware) coun ters } ACCESS read-write STATUS mandatory DESCRIPTION "Value when read will be other. Writing a value to this object will result in the associated action taking place. For those actions which are tests, the result is in lsEportTestResult." ::= { lsEportEntry 14 } lsEportFtoEByteCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of bytes that were forwarded from the FDDI MAC to the Ethernet through the Address Filter. The count per frame includes the packet's bytes as received by the FDDI MAC (FCS removed), plus a number of overhead bytes used internally." REFERENCE "ieee8023IfTable.ieee8023OctetsTxOk" ::= { lsEportEntry 15 } lsEportEtoFByteCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of bytes that were forwarded from the Ethernet MAC to the Address Filter. The count per packet includes the byte count indicated by the Ethernet MAC (without FCS), plus a number of overhead bytes used internally." REFERENCE

"ieee8023IfTable.ieee8023OctetsRxOk" ::= { lsEportEntry 16 } lsEportFtoEPacketCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames that were forwarded from the FDDI MAC to the Ethernet MAC through the Address Filter. The count is the number of frames that the Ethernet MAC was able to transmit." REFERENCE "ieee8023IfTable.ieee8023FrmsTxOk" ::= { lsEportEntry 17 } lsEportEtoFPacketCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames that were forwarded trom the Ethernet MAC to the Address Filter. The count is the number of frames received without error by the Ethernet MAC. Packets may be not-forwarded by the Address Filter and some may encounter error conditions, so it is necessary to subtract the value of lslEportEtoFDropPktCts for the true number of frames." REFERENCE "ieee8023IfTable.ieee8023FrmsRxOk" ::= { lsEportEntry 18 } lsEportFtoEDropPktCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames that were dropped as they went from the FDDI to the Ethernet through the Address Filter. Frames may be dropped due to resource constraints." ::= { lsEportEntry 19 } lsEportEtoFDropPktCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames that were dropped before reaching the FDDI MAC. Include in this value are frames encountering resource constraints, as well as frames which did not need to be forwarded onto the FDDI (i.e., local intra-segment traffic)." ::= { lsEportEntry 20 } lsEportFtoEBusErrorCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames that encountered a Parity or FIFO Error as they went from FDDI to the Ethernet." ::= { lsEportEntry 21 }

lsEportEtoFBusErrorCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames that encountered a Parity or FIFO Error as they went from Ethernet to the FDDI." ::= { lsEportEntry 22 } lsEportXMCastCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames transmitted to a multicast address. Does not include frames sent to the broadcast address." REFERENCE "ieee8023IfTable.ieee8023McastFrmsTxOk" ::= { lsEportEntry 23 } lsEportXBCastCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames transmitted to a broadcast address. Does not include frames sent to the multicast address." REFERENCE "ieee8023IfTable.ieee8023McastFrmsTxOk" ::= { lsEportEntry 24 } lsEportXDirectedCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames transmitted that were not addressed to either the multicast or the broadcast address." ::= { lsEportEntry 25 } lsEportXDeferredCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames for which the first transmission attempt is delayed because the medium is busy. The count does not include frames involved in collisions." REFERENCE "ieee8023IfTable.ieee8023DefTx" ::= { lsEportEntry 26 } lsEportXLateCollCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of times that a collision is detected later 512 bit-times into the transmission of a packet.

A late collision is also considered as a generic collision for purposes of other collision-related counters." REFERENCE "ieee8023IfTable.ieee8023LateColls" ::= { lsEportEntry 27 } lsEportXCollAbortCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames for which transmission fails due to excessive collisions." REFERENCE "ieee8023IfTable.ieee8023ExcessColls" ::= { lsEportEntry 28 } lsEportXCSErrCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame." REFERENCE "ieee8023IfTable.ieee8023CsErrors" ::= { lsEportEntry 29 } lsEportXExcessDeferCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of times that the deferral time was excessive." REFERENCE "ieee8023IfTable.ieee8023ExcessDef" ::= { lsEportEntry 30 } lsEportXUnderrunCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of times that an underrun occured." ::= { lsEportEntry 31 } lsEportXSQETestFailCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of times that the SQE TEST ERROR message is generated by the PLS sublayer for a particular interface. The SQE TEST ERROR message is defined in section 7.2.2.2.4 of ANSI/IEEE 802.3-1985 and its generation is described in section 7.2.4.6 of the same document." REFERENCE "ieee8023IfTable.ieee8023SqeTestErrors"

::= { lsEportEntry 32 } lsEportRMCastCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames received with a multicast address. Does not include frames received with a broadcast address." REFERENCE "ieee8023IfTable.ieee8023McastFrmsRxOk" ::= { lsEportEntry 33 } lsEportRBCastCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames received with a broadcast address. Does not include frames received with a multicast address." REFERENCE "ieee8023IfTable.ieee8023McastFrmsRxOk" ::= { lsEportEntry 34 } lsEportRDirectedCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames received that were not addressed to either the multicast or the broadcast address." ::= { lsEportEntry 35 } lsEportRAlignmentCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. The count represented by an instance of this object is incremented when the 'alignment error' status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC." REFERENCE "ieee8023IfTable.ieee8023AlignErrors" ::= { lsEportEntry 36 } lsEportRTooLongCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames which were received and also

exceeded the maximum frame size." REFERENCE "ieee8023IfTable.ieee8023OorLengthFields" ::= { lsEportEntry 37 } lsEportRFCSErrorCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. The count represented by an instance of this object is incremented when the frameCheckError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC." REFERENCE "ieee8023IfTable.ieee8023FcsErrors" ::= { lsEportEntry 38 } lsEportROverrunCts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames which could not be stored by the Ethernet MAC due to internal resource constraints." ::= { lsEportEntry 39 } lsStationsNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A count of stations whose Physical Address has been detected in the Source Address field of a frame which was transmitted by a station connected to an Ethernet port. Equals the total of all of the per-port stations counts." ::= { linkSwitch 14 } lsStationsTable OBJECT-TYPE SYNTAX SEQUENCE OF LsStationsEntry ACCESS not-accessible STATUS mandatory ::= { linkSwitch 15 } lsStationsEntry OBJECT-TYPE SYNTAX LsStationsEntry ACCESS not-accessible STATUS mandatory INDEX { lsStationsPortIndex, lsStationsAddrIndex } ::= { lsStationsTable 1 } LsStationsEntry ::=

SEQUENCE { lsStationsPortIndex lsStationsAddrIndex lsStationsAddress }

INTEGER, INTEGER, PhysAddress

lsStationsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The lsEportIndex of the port to which the addresses apply." ::= { lsStationsEntry 1 } lsStationsAddrIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of this address within a row of the table lsStationsTable, where the row is selected by the value of lsStationsPortIndex." ::= { lsStationsEntry 2 } lsStationsAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "A Physical Address which has been seen as a Source Address on this port since the last time the Address Filter was aged." ::= { lsStationsEntry 3 } lsBusCts OBJECT-TYPE SYNTAX OCTET STRING (SIZE (192)) ACCESS read-only STATUS mandatory DESCRIPTION "A binary structure which contains the FtoE and EtoF counters for all ls ports. Actual layout available on request." ::= { linkSwitch 16 } lsPortAMediaPresent OBJECT-TYPE SYNTAX INTEGER { other(1), notpresent(2), -- Port A Media not present fiberpresent(3), -- Port A Fiber Media present fiberscpresent(4), -- Port A Fiber SC Media present utppresent(5), -- Port A UTP Media present stppresent(6) -- Port A STP Media present } ACCESS read-only STATUS mandatory DESCRIPTION "Reports presence and type of FDDI Port A Media. For FMS LinkSwitch, only Fiber and UTP are supported." ::= { linkSwitch 17 } lsPortBMediaPresent OBJECT-TYPE SYNTAX INTEGER {

other(1), notpresent(2), -- Port B Media not present fiberpresent(3), -- Port B Fiber Media present fiberscpresent(4), -- Port B Fiber SC Media present utppresent(5), -- Port B UTP Media present stppresent(6) -- Port B STP Media present } ACCESS read-only STATUS mandatory DESCRIPTION "Reports presence and type of FDDI Port B Media. For FMS LinkSwitch, only Fiber and UTP are supported." ::= { linkSwitch 18 } lsFMSBackupPSSense OBJECT-TYPE SYNTAX INTEGER { other(1), notpresent(2), goodstatus(3), badstatus(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports the presence and status of the backup power supply on FMS LinkSwitch Only." ::= { linkSwitch 19 } lsfddiPATHRingLatency OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Reports the measurement (in 80 nanosecond ticks) of total accumulated latency of the ring associated with the current path." ::= { linkSwitch 20 } END