Sie sind auf Seite 1von 2

Product Selector Guide

Transmission Line Protection Selector Guide


Transmission Line Protection

Features
Distance Line Differential - Current Comparison Line Differential - Phase Comparison Breaker-and-Half configurations Series Compensation Three terminal lines Lines with In-zone transformers Synchrophasors

Device
21 87L 87PC

D30

Applications

<2 3 3 G/N/P/_2 G/N/P/_2 N/P/_2 P/X/N P/X 4 3 512 6 16 80 64 32 64 2 48 12 24 24 1024 64/5 1

Typical Operating Time (cycles) Mho Phase & Ground Distance (No. of Zones) Quad Phase & Ground Distance (No. of Zones) IOC, Ground/Neutral/Phase/Negative Sequence TOC, Ground/Neutral/Phase/Negative Sequence Directional overcurrent, Neutral/Phase/Neg. Seq. Wattmetric Ground Directional Overvoltage Phase/Auxiliary/Neutral Undervoltage Phase/Auxiliary Negative Sequence Overvoltage Under/Over frequency Out-of-Step Blocking/Tripping Switch on to Fault (Line Pickup) Voltage Transformer Fuse Failure Current Transformer Supervision Open Pole Detector Load Encroachment Logic Breaker Failure Breaker Flashover Lockout Functionality Synchronism Check or Synchronizing AC Reclosing (No. of Shots) Trip Modes: Three-Pole/Single-Pole Pilot Protection Logic Fault Location Programmable Protection Logic (no of lines) Programmable Automation Logic (no of lines) FlexElements User Programmable Self-Test Contact Settings Groups Non-volatile latches (up to) Contact Inputs Programmable - (up to) Contact Outputs Programmable - (up to) Virtual Inputs - (up to) Virtual Outputs - (up to) Direct Inputs/Outputs Breaker Control (up to) User-Programmable LEDs (up to) User - Programmable Annunciator Alarms (up to) User-Programmable Push Buttons (up to) User-Programmable Self Test User Definable Displays Large HMI Timers Selector Switch Digital Counters Digital Elements IRIG-B Input Analog Inputs/Outputs (up to) RTD Inputs (up to) Current, voltage Symmetrical Components Power - Apparent, Real, Reactive Energy Power Factor Frequency Fault Location Event Recorder - Number of Events Oscillography - Sampling Rate Disturbance Recorder - Sampling Rate/Duration in seconds Breaker Arcing Current Trip/Close Coil Supervision Data Logger RS232 Port USB Port RS485 Port Ethernet Port (Fiber and Copper, up to) Direct Fiber Communications (800nm, 1330nm, 1550nm) Communication Interface (RS422, G.703, C37.94) ModBus (RTU and TCP/IP) DNP3 IEC60870-5-104 UCA2/MMS IEC61850 Simple Network Time Protocol (SNTP) HTTP TFTP Process Bus (IEC 61850-9-2)

Protection & Control

21P/G 21P/G 50G/N/P/_2 51G/N/P/_2 67G/N/P/_2 59P/X/N 27P/X 59_2 81U/O 68B SOTF VTFF

50BF 86 25 79

Automation

Monitoring & Metering

Communications Interfaces

Protocols

* For the most current comparison list, see www.GEMultilin.com/selector/transmission.pdf

198

www.GEDigitalEnergy.com

Product Selector Guide

D60
<2 5 5 G/N/P/_2 G/N/P/_2 N/P/_2 P/X/N P/X 4 1&3 512 6 16 80 64 32 64 2 48 12 24 24 1024 64/5 1

D90Plus
<1 5 5 G/N/P/_2 G/N/P/_2 N/P/_2 P/X/N P/X 4 1&3

L30
<1 G/N/P/_2 G/N/P/_2 P/X P/X u 4 3 512 6 16 80 64 32 64 2 48 12 24 24 1024 64/5 1

L60
<1 3 3 G/N/P/_2 G/N/P/_2 N/P/_2 P/X/N P/X 4 1& 3 POTT 512 6 16 80 64 32 64 2 48 12 24 24 1024 64/5 1

L90
<1 3 3 G/N/P/_2 G/N/P/_2 N/P/_2 P/X/N P/X 4 1&3 POTT 512 6 16 80 64 32 64 2 48 12 24 24 1024 64/5 1

512 1024 6 16 60 60 32 64 2 96 12

8000 128/30 1/300 3

www.GEDigitalEnergy.com

199

Transmission Line Protection

Das könnte Ihnen auch gefallen