SEISMIC CALCULATIONS

TANK SUPPORT

Page 38 - 1

38

Christy 8:29
11/25/13

ENGINEERING with the SPREADSHEET Copyright 2006 American Society of Civil Engineers 191196532.xls.ms_office
A B C D E F G H I J K L M N

SEISMIC CALCULATION WORKSHEET Z 0.3 unit seismic zone factor soil SD soil profile type

V = 0.304 W_Ultimate = 0.217 W_working stress ZONE 1 2A 2B 3 4 Z 0.075 0.15 0.2 0.3 0.4

Copy clip table values to reduce transcription errors. SOIL PROFILE TYPE SA Hard rock SB Rock SC Very dense soil & soft rock SD Stiff soil SE Soft soil SF Soil requiring evaluation

logic blows/ft 0 >50 0 15 to 50 0 row 20 <15 5 0 0 5

SEISMIC COEFFICIENT CA UBC TABLE 16 Q SOIL SEISMIC ZONE FACTOR, Z TYPE 0.075 0.150 0.200 SA 0.06 0.12 0.16 SB 0.08 0.15 0.20 SC 0.09 0.18 0.24 SD 0.12 0.22 0.28 SE 0.19 0.30 0.34 SF Soil requiring evaluation Ca 0.36 unitless

0.300 0.24 0.30 0.33 0.36 0.36

0.400 0.32 0.40 0.40 0.44 0.36

row 30

Ca

The coefficient that defines the short period ground motion for structures with a fundamental period < Cv /2.5 Ca . row 40

SEISMIC COEFFICIENT Cv 97 UBC TABLE 16 R SOIL SEISMIC ZONE FACTOR, Z TYPE 0.075 0.150 0.200 0.300 SA 0.06 0.12 0.16 0.24 SB 0.08 0.15 0.20 0.30 SC 0.13 0.25 0.32 0.45 SD 0.18 0.32 0.40 0.54 SE 0.26 0.50 0.64 0.84 SF Soil requiring evaluation Cv 0.54

0.400 0.32 0.40 0.56 0.64 0.96

Cv

logic 0 0 0 5 0 row 50 0 5 The coefficient that defines the longer period constant velocity ground motion.

The first five soil profile types are based upon soil shear wave velocity. Values for SF require a soil specific evaluation to establish site coefficients. row 60

SEISMIC CALCULATIONS
TANK SUPPORT

Page 38 - 2

38

Christy 8:29
11/25/13

ENGINEERING with the SPREADSHEET Copyright 2006 American Society of Civil Engineers 191196532.xls.ms_office
A B C D E F G H I J K L M N

NEAR-SOURCE FACTOR Na 97 UBC TABLE 16 S ZONE 4 CALCULATION V = 0.304 W_Ultimate = 0.217 W_working stress Distance 5 Km 3.11 miles -- Closest distance to known seismic source in Km type C Seismic source type SEISMIC SOURCE TYPE 97 UBC TABLE 16 U The near source factors Na and Nv apply to Zone 4 A Faults that can produce large calculations UBC 1628 Symbols and Notations magnitude events and have a high rate of activity B All faults other than A or C row 70 CLOSEST DISTANCE TO KNOWN SEISMIC SOURCE (Km) 2.00 5.00 10.00 and greater 0 1 1 1 0 0 0 1 0 1.50 1.20 1.00 1.00 1.30 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Na C Faults that are not capable of producing large magnitude events and have a low rate of activity logic 0 0 4 4 The acceleration based factor for short period structures choose 5 10 5 hlookup 1 1 5 1 row 90

SEISMIC SOURCE TYPE A B C Na

NEAR-SOURCE FACTOR Nv 97 UBC TABLE 16 T ZONE 4 APPLICATION Distance 5 Km 3.11 miles -- Closest distance to known seismic source in Km type C Seismic source type CLOSEST DISTANCE TO KNOWN SEISMIC SOURCE (Km) 2.00 5.00 10.00 15.00 and greater 0 1 1 1 1 0 0 0 0 1 0 0 2.00 1.60 1.20 1.00 1.60 1.20 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Nv The velocity based factor for ground motion periods > 1 second

SEISMIC SOURCE TYPE A B C Nv

logic 0 0 4 4 choose 5 10 5 hlookup 1 1 5 Parts of the Oregon coast have been reclassified to Zone 4. More of western Oregon and Washington may be reclassified to Zone 4 in the future. 1

NEAR-SOURCE CALCULATIONS Ca 0.36 unitless soil type factor 97 UBC Table 16Q Na 1.00 unitless near source factor from above Ca*Na 0.36 unitless Ca*Na in Zone 4 UBC 1628 Symbols IF(0.3 zone = 0.4 , 1.00 * 0.36 , 0.36 )

Cv Nv Cv*Nv

0.54 unitless 1.00 unitless 0.54 unitless

seismic coefficient 97 UBC Table 16R near source factor from above near source factor Nv used in Zone 4 IF(0.3 = 0.4 , 0.54 * 1.00Nv , 0.54 ) see UBC 1628 Symbols and Notations

Check with the local Building Official as to which seismic zone and near source factors may be required.

row 110

SEISMIC CALCULATIONS
TANK SUPPORT

Page 38 - 3

38

Christy 8:29
11/25/13

ENGINEERING with the SPREADSHEET Copyright 2006 American Society of Civil Engineers 191196532.xls.ms_office
A B C D E F G H I J K L M N

SEISMIC CALCULATION WORKSHEET -- Continued Z 0.3 unitless zone acceleration factor from above soil SD alpha soil type Stiff soil R 2.9 unitless

TABLE 16-P - R FACTORS for NONBUILDING STRUCTURES 11. All other structures not otherwise covered.

V = 0.304 W_Ultimate = 0.217 W_working stress The structure response factor based upon the structure configuration, stiffness, and force amplification characteristics in an earthquake leading to a ratio of seismic base shear to the ability of the structure to absorb energy and inelastic deformations without collapse. Note that the structure may be rendered useless by the seismic event that it was designed for under this system. However, some designs account for inelastic deformations and the continued use of the structure with or without repairs.

I hn Ct

1.25 unitless 75 ft 0.030 unitless

importance factor

building height building period factor based upon construction style 97 UBC 1630.2.2 Ct = 0.030 for reinforced concrete moment-resisting frames and eccentrically braced frames. I

importance factor

0.765 seconds

Ct * hn^0.75 . (30-8) natural period .. T > 0.06 Flexible nonbuilding structure .. 0.030 * (75.0^0.75 ) use UBC 1630.5 V = Ft + sum Fi .. 0.7 * Ca * I * W (34-1) 0.7 * 0.36 * 1.25 * W V lateral force, * W

row 130

V rigid

0.315 * W

V flexible

0.304 *W

Cv * I / (R * T) *W (30-4) 0.54 * 1.25 / (2.9 * 0.765) * W flexible structure ..

1630.2.2 Ct = 0.035 for steel moment resisting frames Ct = 0.030 for reinforced concrete moment-resisting frames and eccentrically braced frames. Ct = 0.020 for all other buildings row 140

0.304 *W

Vmax

0.388 *W

2.5 * Ca * I

/ R * W (30-5)

maximium lateral force

2.5 * 0.36 * 1.25 / 2.9 * W

Vmin

0.050 *W

0.11 * Ca * I * W (30-6) 0.11 * 0.36 * 1.25 * W

this value sets the lower bounds for long period structures Ca is multplied by Na in Zone 4 calculations

Structure

1 input

0 = building structure 0.8 in (30-7), 1 = non building structure 1.6 in (34-3)

row 150

Vmin_4a

0.252 *W 1 logic

0.56 * Ca * I * W (34-2) 0.56 * 0.36 * 1.25 * W for flexible nonbuilding structures 1634.5

for non-building structures Ca is multplied by Na in Zone 4 calculations

row 160

SEISMIC CALCULATIONS
TANK SUPPORT

Page 38 - 4

38

Christy 8:29
11/25/13

ENGINEERING with the SPREADSHEET Copyright 2006 American Society of Civil Engineers 191196532.xls.ms_office
A B C D E F G H I J K L M N

SEISMIC CALCULATION WORKSHEET -- Continued 1.00 unitless 0.207 *W near source factor for Zone 4 calculations 0.8 in (30-7), 1.6 in (34-3) * Z * Nv * I 1.6 * 0.30 * 1.00 * 1.25 / 2.9 * W 0.3 = 0.4 is not Zone 4 ..

V = 0.304 W_Ultimate

= 0.217 W_working stress

Vmin_4b

/ R

* W (34-3)

zone

0 logic

V_appliedu

0.304 *W_ultimate strength T > 0.06 Flexible nonbuilding structure .. 0.217 *W_working stress T > 0.06 Flexible nonbuilding structure ..

V_appliedw

TABLE 16-P - R FACTORS for NONBUILDING STRUCTURES 1. Tanks, vessels or pressurized 2.2 2.0 spheres on braced or unbraced legs 5. Inverted pendulum type structures 2.2 2.0 Cantilevered column building systems 9. Signs and billboards 3.6 2.0 11. All other structures not 2.9 2.0 otherwise covered.

Non-Building Structures at Grade UBC 1634 V 0.217 *W applied For nonbuilding structures at / or below grade weight 60000 lbs gross weight of item CG 240 in M_ot bolt_brg CG_rt M_rt Bolts t tension Bolts v shear 3131288 in-lbs 90 in 30.00 in 1530000 in-lbs 2 8896 lbs 4 3262 lbs 0.217 g * 240.00" * 60,000 lbs bolt to bearing to resist overturning arm in plan view to cg of gross weight 0.85 * 60,000 lbs* 30.00 in

( 3,131,288 - 1,530,000 ) in-lbs / 90.00 in / 2 bolts

row 190 2/3 OVERALL HEIGHT per UBC 1630.2.2 for FLEXIBLE NON-BUILDING STRUCTURES

0.217 * 60,000 lbs / 4 bolts 20.00 ft

row 200

Figure 38-1 FLEXIBLE STRUCTURE

#####