Synonyms XDP, Fragment D-dimer, Fibrin degradation fragment. Test Description The D-dimer assay is specific for fibrin derivatives. In this assay, the presence of cross-linked D-dimer domain is diagnostic for lysis of a fibrin clot, and confirm that thrombin was formed and Factor XIII was activated with reactive fibrinolysis. Since fibrinogen derivatives do not contain the cross-linked D-dimer domain, they are not recognized by the D-dimer assay, even when present in high concentration. In other words, fibrin derivatives in plasma containing D-Dimer (XDP) are specific markers for fibrinolysis, as opposed to fibrinogenolysis. D-dimers are detected by immunoassays using monoclonal antibodies specific for the cross-linked D-dimer domain in fibrinogen. Commercially available assays include latex agglutination, immunoturbidimetry, and ELISA. No specific patient preparation is required for the measurement of D-dimers.

Patient Preparation Specimen Specimen Collection and Preparation

Citrated, platelet-poor plasma is used for the D-dimer assay. Citrated, platelet-poor plasma is prepared from venous blood collected by venipuncture or from an indwelling catheter. The blood is collected into 3.2%) trisodium citrate at a ratio of 9:1. The blue-top tube automatically fills to the correct volume; spurious results may occur if this ratio is not maintained. The citrate concentration must be adjusted in patients with a HCT >55%. Plasma should be separated from the cells as soon as possible after the specimen is obtained. D-dimers are stable for 8 hours in citrated plasma maintained at room temperature, for seven days if stored at 2-8oC, and up to two months at -20oC. D-dimers are detected by immunoassays using monoclonal antibodies specific for the cross-linked D-dimer domain in fibrinogen. Present commercially available assays are based on particle agglutination, immunoturbidimetry, and ELISA. ELISA assays are the reference standard for D-dimer quantitation. These assays utilize microtiter wells coated with an antibody with a high affinity for D-dimer. Incubation with plasma results in the binding of any D-dimer present. A labeled antibody is then added and the amount of bound labeled substance is determined by a colormetric reaction. In spite of their high sensitivity and specificity, conventional ELISA assays are expensive, labor intensive, and time consuming to perform. Therefore, they have not been practical in most clinical situations, where rapidly available results are needed. Latex agglutination (LA) assays use latex microparticles coated with monoclonal antibodies specific for D-dimer. Incubation with plasma results in the formation of macroscopic agglutinates. The sensitivity of the assay is usually adjusted to 1 g/ml during the manufacture of the latex particles. Although conventional latex agglutination as-

Test Methodology

D-Dimer Assays

Test Methodology

says are inexpensive and rapid to perform, numerous studies have shown that they lack the sensitivity to detect D-dimers in critical clinical situations, particularly in the detection of pulmonary embolism and acute venous thrombosis. Immunoturbidometric assays are automated microparticle assays in which a beam of monochromatic light is passed through a suspension of latex microparticles coated by covalent bonding with monoclonal antibodies specific for D-dimer. The wavelength of the light (540 nm) is greater than the diameter of the latex microparticles and so the solution of latex microparticles only slightly absorbs the light. When the plasma is added to the suspension, any D-dimer present in the sample causes the latex microparticles to agglutinate, becoming aggregates with diameters greater than the wavelength of the light. This increases the absorbance of the light, which is measured photometrically, and proportional to the amount of D-dimer present in the test sample. These assays are cost effective, relatively rapid to perform, and have a sensitivity comparable to conventional ELISA. A commercially available whole blood assay for D-dimer uses a bispecific antibody specific for D-dimer and a red blood cell antigen. A drop of whole blood is incubated with the monoclonal antibody solution, causing visible agglutination of the red cells if Ddimers are present. Many reports have indicated a high sensitivity for the assay, and it is widely used in clinical settings.

Normal Values and Critical Limits

The reporting standard for D-dimers varies with the test methodology and reagent manufacturer. Latex and whole blood agglutination results are usually reported as a D-dimer range (ng/mL). ELISA and immunoturbidimetric assays are usually reported in fibrinogen equivalent units (FEU). One FEU is the quantity of fibrinogen that was initially present before it was broken down. The actual quantity of D-dimer is approximately half of an FEU (when 1.0 of fibrinogen g/ mL is broken down, 0.5 g/mL of D-Dimer remain). Rheumatoid factor may cause a false positive D-dimer assay. Lipemia may interfere with immunoturbidimetric and ELISA assays. XDPs are cross-linked fibrin degradation products which arise directly from fibrin. Thus, the measurement of XDPs, unlike total FDPs, is a specific measure of fibrinolysis. Elevated D dimers are seen in DIC, pulmonary embolism, arterial and venous thrombosis, septicemia, cirrhosis, carcinoma, sickle cell crisis, and following operative procedures. Both FDPs and XDPs are present during late pregnancy and for approximately 48 hours post-surgery. During fibrinolytic therapy the FDP test is positive, while the D-dimer test is negative in the absence of thrombolysis. Disseminated intravascular coagulation (DIC, consumption coagulopathy) is one of the most common and clinically important acquired disorders of hemostasis. In DIC, intravascular activation of the coagulation system results in the widespread deposition of fibrin microthrombi in the microcirculation, the consumption of platelets and clotting factors, and activation of the fibrinolytic system. At the same time that thrombin converts fibrinogen to fibrin, it also activated Factor XIII to form a plasma transglutaminase, Factor XIIIa, which stabilizes fibrin by cross-linking the gamma chains of fibrinogen in the region of the D-domain. Plasmin digests fibrin and fibrinogen to produce fibrin(ogen) degradation (FDP) (or split, FSP) products (X,Y,D, and E), which are removed from the circulation by the reticuloendothelial system.

Interferences

Clinical Utilization

D-Dimer Assays

Clinical Utilization

DIC is not a specific disease, but a sequalae of many pathologic conditions, including acute intravascular hemolysis, hemolytic transfusion reactions, shock, hyperthermia, extensive tissue damage, malignancies, obstetric complications, hyperthermia, snake bites, etc. Prompt diagnosis and therapy of DIC is essential, since the associated hemorrhage, small vessel thrombosis, and occasional large vessel thrombosis can lead to the impairment of blood flow, ischemia, end-organ damage, and death. The clinical signs and symptoms in DIC are variable and non-specific, and include fever, hypotension, acidosis, proteinuria, hypoxia, petechiae and purpura, subcutaneous hematomas, bleeding (surgical wound, traumatic wound, venipuncture), and arterial line oozing. There is no laboratory assay pathognomonic of DIC. However, peripheral smear examination is among the most helpful. In fulminent cases, this shows a characteristic combination of schistocytes (red blood cell fragments), mild polychromatophilia, leukocytosis with a left shift, thrombocytopenia, and large young platelets. However, the diagnosis of DIC cannot be excluded by an absence of schistocytes, since these occur in only 50% of patients. In addition to peripheral smear review, the prothrombin time (PT), activated partial thromboplastin time (aPTT), platelet count, and serum fibrin/ fibrinogen degradation products are the best screening tests for DIC. The D-dimer assay is more specific, and can be used to confirm the diagnosis. The D-dimer has received much attention in recent years as a critical part of the evaluation of emergency care patients with suspected pulmonary embolism (PE) or deep venous thrombosis (DVT). Generally, numerous studies have shown that the more advanced ELISA and immunoturbidometric assays have a sensitivity of 90% or greater for PE or DVT in this setting, and a negative predictive value of 90% or greater for the exclusion of disease. However, there is presently much debate about how the results should be correlated with other findings, particularly radiographic studies. The analysis of plasma D-dimers has been reported to be of diagnostic value in patients with suspected complications of pregnancy such as pre-eclampsia and the HELLP syndrome, to monitor anticoagulant and thrombolytic therapy, and to correlate with disease severity in rheumatoid arthritis. CSF D-dimers have been reported positive in patients with subarachnoid hemorrhage, but not in normal patients or those with traumatic lumbar puncture.

References

Andreescu AC, Cushman M, Rosendaal FR: D-dimer as a risk factor for deep vein thrombosis: the Leiden Thrombophilia Study. Thromb Haemost 87:47-51, 2002 Arkel YS, Paidas MJ, Ku DH: The use of coagulation activation markers (soluble fibrin polymer, TpP, prothrombin fragment 1.2, thrombin-antithrombin, and Ddimer) in the assessment of hypercoagulability in patients with inherited and acquired prothrombotic disorders. Blood Coagul Fibrinolysis 13:199-205, 2002 Bates SM, Kearon C, Crowther M, et al: A diagnostic strategy involving a quantitative latex D-dimer assay reliably excludes deep venous thrombosis. Ann Intern Med 138:787-794, 2003 Bosson JL, Barro C, Satger B, et al: Quantitative high D-dimer value

is predictive of pulmonary embolism occurrence independently of clinical score in a well-defined low risk factor population. J Thromb Haemost 3:93-99, 2005 Brown MD, Lau J, Nelson RD, et al: Turbidimetric D-dimer test in the diagnosis of pulmonary embolism: a metaanalysis. Clin Chem 49:1846-1853, 2003 Caine GJ, Lip GY: D-dimer tests for assessment of patients with suspected pulmonary embolism. Arch Intern Med 163:243, 2003 Epiney M, Boehlen F, Boulvain M, et al: D-dimer levels during delivery and the postpartum. J Thromb Haemost 3:268-271, 2005 Falanga A: The predictive value of D-dimer measurement for cancer in patients with deep vein throm-

bosis. Haematologica 90:149b, 2005 Fancher TL, White RH, Kravitz RL: Combined use of rapid D-dimer testing and estimation of clinical probability in the diagnosis of deep vein thrombosis: systematic review. Bmj 329:821, 2004 Froehling DA, Elkin PL, Swensen SJ, et al: Sensitivity and specificity of the semiquantitative latex agglutination D-dimer assay for the diagnosis of acute pulmonary embolism as defined by computed tomographic angiography. Mayo Clin Proc 79:164-168, 2004 Gardiner C, Pennaneac'h C, Walford C, et al: An evaluation of rapid D-dimer assays for the exclusion of deep vein thrombosis. Br J Haematol 128:842-848, 2005

D-Dimer Assays
References (Contd)
Gosselin RC, Owings JT, Kehoe J, et al: Comparison of six D-dimer methods in patients suspected of deep vein thrombosis. Blood Coagul Fibrinolysis 14:545-550, 2003 Heim SW, Schectman JM, Siadaty MS, et al: D-dimer testing for deep venous thrombosis: a metaanalysis. Clin Chem 50:1136-1147, 2004 Ireland B: Negative ELISA D-dimer assay can miss pulmonary embolism. J Fam Pract 52:99, 103, 2003 Le Gal G, Bounameaux H: Ddimer for the diagnosis of pulmonary embolism: a call for sticking to evidence. Intensive Care Med 31:1-2, 2005 Lippi G, Guidi GC: Effect of specimen collection on routine coagulation assays and D-dimer measurement. Clin Chem 50:2150-2152, 2004 Mavromatis BH, Kessler CM: Ddimer testing: the role of the clinical laboratory in the diagnosis of pulmonary embolism. J Clin Pathol 54:664-668, 2001 Monaco J, Newton W: Elevated Ddimer level predicts recurrent VTE. J Fam Pract 53:20, 23, 2004 Monreal L: D-dimer as a new test for the diagnosis of DIC and thromboembolic disease. J Vet Intern Med 17:757-759, 2003 Oswald CT, Menon V, Stouffer GA: The use of D-dimer in emergency room patients with suspected deep vein thrombosis: a test whose time has come. J Thromb Haemost 1:635-636, 2003 Perrier A: D-dimer for suspected pulmonary embolism: whom should we test? Chest 125:807-809, 2004 Perrier A, Palareti G: D-dimer testing and venous thromboembolism: four view points. J Thromb Haemost 3:382-384, 2005 Reber G, Bounameaux H, Perrier A, et al: A new rapid point-of-care D-dimer enzyme-linked immunosorbent assay (Stratus CS Ddimer) for the exclusion of venous thromboembolism. Blood Coagul Fibrinolysis 15:435-438, 2004 Saigo M, Waters DD, Abe S, et al: Soluble fibrin, C-reactive protein, fibrinogen, factor VII, antithrombin, proteins C and S, tissue factor, Ddimer, and prothrombin fragment 1 + 2 in men with acute myocardial infarction </=45 years of age. Am J Cardiol 94:1410-1413, 2004 Schutgens RE, Haas FJ, Gerritsen WB, et al: The usefulness of five D-dimer assays in the exclusion of deep venous thrombosis. J Thromb Haemost 1:976-981, 2003 Shitrit D, Izbicki G, Shitrit AB, et al: Prognostic value of a new quantitative D-dimer test in critically ill patients 24 and 48 h following admission to the intensive care unit. Blood Coagul Fibrinolysis 15:15-19, 2004

Siragusa S: Plasma D-dimer test accuracy can be affected by heparin administration. Arch Intern Med 163:246; author reply 247, 2003 Sivakumaran M, Malton N: Plasma D-dimer measurement as a predictor of venous thrombosis. Blood 102:4618, 2003 Stein PD, Hull RD, Patel KC, et al: D-dimer for the exclusion of acute venous thrombosis and pulmonary embolism: a systematic review. Ann Intern Med 140:589-602, 2004 Stern SD: D-dimer in venous thromboembolism. N Engl J Med 350:192-194, 2004 Ver Elst K, Jochmans K, De Pauw A, et al: Plasma D-dimer concentrations in different clinical conditions. Acta Clin Belg 57:325-330, 2002 Wakai A, Gleeson A, Winter D: Role of fibrin D-dimer testing in emergency medicine. Emerg Med J 20:319-325, 2003 Wilson DB, Gard KM: Evaluation of an automated, latex-enhanced turbidimetric D-dimer test (advanced D-dimer) and usefulness in the exclusion of acute thromboembolic disease. Am J Clin Pathol 120:930-937, 2003 Wolf SJ: D-dimer and venous thromboembolism. Ann Intern Med 141:481; author reply 483, 2004