Beruflich Dokumente
Kultur Dokumente
Client
End User
Project
P.O. No.
CPI Order No.
Stress Analysis Report No.
16.12.200
8
29.09.200
8
Issue
:
:
:
:
:
MV
PK
FM
MV
PK
FM
Rev
Revision Description
Prepared by
Checked by
Approved by
Page 1 of 6
Date
1. INTRODUCTION
The stress analysis has been carried out for the 10 and 6 GRE Pipeline
inclusive of station approach piping network for the Aquifer Pump-Off (APO)
system covered by the below mentioned drawings.
The CAESAR II Version 5.10, developed by COADE, Houston, Texas, has been
used for the analysis. CAESAR II is a PC based pipe stress analysis software
program used in the design and analysis of the piping systems and is based on
simple beam theory. The various types of loadings and piping details are given
in the input based on which the software produces results in the form of
displacements, loads and stresses throughout the piping system.
The GRE piping network is mainly of underground construction.
2. APPLICABLE CODES
The applicable code for the analysis is UKOOA. ISO 14692 is regarded as the
development of UKOOA code.
3. DRAWING NUMBERS AND CALCULATION NUMBERS
SL #
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
Drawing Number
QSP-450-MP-4024-37001-0001-A1-03
#3706)
QSP-450-LA-2373-37004-0001-A1-02
QSP-450-LA-2373-37004-0002-A1-02
QSP-450-MP-4024-37002-0001-A1-02
#3706)
QSP-450-LA-2373-37002-0001-A1-02
QSP-450-LA-2373-37002-0002-A1-03
QSP-450-LA-2373-37002-0003-A1-02
QSP-450-LA-2373-37002-0004-A1-02
QSP-450-LA-2373-37002-0005-A1-02
QSP-450-LA-2373-37002-0006-A1-02
QSP-450-LA-2373-37002-0007-A1-02
QSP-450-LA-2373-37002-0008-A1-02
QSP-450-LA-2373-37002-0009-A1-02
QSP-450-LA-2373-37002-0010-A1-02
QSP-450-LA-2373-37002-0011-A1-02
QSP-450-LA-2373-37002-0012-A1-02
QSP-450-MP-4024-37001-0001-A1-03
#3705)
QSP-450-LA-2373-37005-0001-A1-02
QSP-450-MP-4024-37003-0001-A1-02
#3705)
FWNETWORK
(well
Calculation Number
CPI-SA-0417-001
Rev.A
(well
(well
(well
Page 2 of 6
20
21
22
QSP-450-MP-4024-37001-0001-A1-03 (well
#3704)
QSP-450-LA-2373-37006-0001-A1-02
QSP-450-MP-4024-37003-0001-A1-02 (well
#3704)
Remarks
Underground
Underground
Reinforced
Reinforced
Reinforced
Remarks
Underground
Underground
Underground
Reinforced
5. DESIGN CONDITIONS
The design conditions used in the stress analysis are as follows:
Design Pressure, P1
HydroTest Pressure, P2
Design Temperature, T1
Design Temperature, T2
Installation Temperature
FWNETWORK
:
:
:
:
: 40 Bar
60 Bar
82 C for above ground
70 C for under ground
5 C
: 35C
Page 3 of 6
Fluid density
: 1000 Kg/m3
To meet the requirements of code, separate stress analysis runs has been
carried out with f2 factor 0.83 (Operating-sustained plus thermal), f2 factor 0.67
(Sustained) and f2 factor 0.89 (Occasional-Hydrotest)
6. ALLOWABLE STRESSES
The allowable stresses for the material calculated by the CAESAR II program are
as per UKOOA code and are listed in the attached stress report for the GRE
material
The part factor f2 is related to confidence in the GRE pipe system, the nature of
the application and consequence of failure. The assessment and evaluation of
the different loading conditions of the system has been analyzed considering
the different f2 factors as per UKOOA. The allowable stress values with different
f2 factors on different loading conditions are given below:
The allowable stress for f2=0.67 is 39.8 N/mm2 (Sustained)
The allowable stress for f2=0.83 is 49.3 N/mm2 (Sustained plus ThermalOperating)
The allowable stress for f2=0.89 is 52.8 N/mm2 (Occasional-Hydrotest)
7. DISPLACEMENTS
No displacements considered at the well head tie-ins intersections. The CS lines
are included in the model upto the well head anchor and the connecting CS
lines at the midline tie-ins with the 10 header. The well head anchor loads shall
be considered for the design of pipe supports. For the 10 pipeline, the
displacements (or) forces produced near the QASP (node no. 2450) shall be
incorporated in the on-plot stress analysis model. The stress ratios near the GRE
Tee (10 X 6) at the mid line tie-ins are given in the attached stress summary.
8. LOAD CASES
The following load cases considered in the analysis:
W+T1+P1 (OPE)
Case 1
W+T2+P1 (OPE)
Case 2
W+P1
(SUS)
Case 3
W+P2
(HYD)
Case 4
Where,
W = Weight of Filled Pipe
P1 = Design pressure, bar
P2 = Hydrotesting pressure, bar
T1 = Design temperature, oC
T2 = Operating temperature, oC
9. SUPPORTING
FWNETWORK
Page 4 of 6
The support loads are shown in the attached restraint summary. The location
and type of supports are marked in the attached well hook up drawings. The
support structure shall be designed by client considering the respective support
loads from restraint summary.
The recommended support (Thrust block) for 10 underground GRE Pipeline
near the station approach has been listed down. The locations are identified on
the alignment sheets as given below. For loads refer to Table 2 for proper
design of Thrust blocks.
Table 1: Thrust blocks identification.
Node Number
Drawing Numbers
1200
QSP-450-MP-4024-37002-0001-A1 02
2350
QSP-450-LA-2373-37002-0012-A1 02
Table 2: APO - 10" GRE PIPE LINE THRUST BLOCK LOADS (N) AND MOMENTS (N-m)
NODE
NO
1200
44942
-1566
-90895
101410.73
866
-214
486
1015.84
2350
-47877
-2815
-81526
94586.57
911
-1
-534
1055.97
SL.NO
Fx
Fy
Fz
Fresultant
Mx
My
Mz
Mresultant
To over-come high stresses in few location of Pipeline the reinforced pipes and
fittings has been recommended to safe-guard the system. The location and
respective node numbers are mentioned in below tables for proper
identification.
Table 3: APO - PIPE REINFORCEMENT THICKNESS
FWNETWORK
115
REF. PIPE
THICKNESS
(MM)
12
PIPE
LENGTH
(MM)
930
125
165
12
2784
150
495
545
12
2472
150
555
590
12
931
250
1060
1095
15
1745
250
1105
1195
15
2204
250
1205
1210
15
9000
250
2255
2295
10
10359
250
2335
2345
10
9000
10
11
250
2355
2395
15
2502
250
2405
2500
15
4822
12
150
2660
2695
12
930
13
150
2705
2795
12
2784
NODE NO
SL.NO
SIZE
(mm)
FROM
TO
150
80
150
Page 5 of 6
14
150
2955
3045
12
2366
15
150
3055
3090
12
922
16
150
3660
3685
12
930
17
150
3695
3795
12
2784
18
150
4055
4145
12
2667
19
150
4155
4190
12
922
NODE NO
ANGLE
SIZE
QTY
1600
20
60O
250
20
250
250
2
3
1900
2250
20
60
45
10. CONCLUSION
All stresses are within the allowable limits if all the points specified in Section 9,
Remarks is followed as well as the piping system operates within the design
conditions as specified in the Section 5 of the report.
* * * * * * * * * *
FWNETWORK
Page 6 of 6