These devices comply with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) These devices may not cause harmful interference, and (2) These devices must accept any interference received, including interference that may cause harmful operation. Please refer to the full FCC and IC statements found in the appendix at the end of this quick start guide.

Contents
Arrow M2M Access Kits !
Kit Contents ! EK2410EX Kit! EK0910EX Kit! Contents! Download Supporting Materials ! Synapse RF100 RF Engine! Synapse RF300 RF Engine! SNAP Connect E10! SNAP Software! Exosite Portal!

1
1 2 2 3 3 3 3 3 4 4

Unpack, Assemble, Power Up !


Assemble the ProtoBoards ! Assemble the EK2410EX with RF100 Module! Assemble the EK0910EX with RF300 Module! Power Up the ProtoBoards ! Attach the E10 to the Internet! Conclusion !

5
5 6 8 10 10 11

Congure Exosite!
Create an Exosite Account ! Congure your Synapse Modules! Add the SNAP Connect E10 to Exosite! Add the Two ProtoBoards to Exosite! Conclusion !

12
12 13 14 16 18

Using Your Kit!


Navigating Exosite Overview ! Menu Items! ProtoBoard Data! The Dashboard ! Data Page! Devices Page! Conclusion !

19
19 20 21 22 24 26 27

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide

Regulatory Information and Certications!


28
28 28 29 29 29

RF exposure statement! FCC certications and regulatory information (USA only) ! Modications (FCC 15.21) ! Declaration of Conformity ! Industry Canada (IC) certications !

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide

Arrow M2M Access Kits


Thank you for evaluating the Arrow M2M Access Kits EK2410EX and EK0910EX. These starter kits are brought to you through a partnership between Arrow Electronics, Inc., Exosite, and Synapse Wireless, Inc. The purpose of the kits is to demonstrate machine to machine communications technologies, including a wireless, personal area network bridged to the internet and accessed using cloud services provided by Exosite. The wireless network components in the kit are provided by Synapse Wireless, running the SNAP OS platform. The document you are now reading will guide you through the setup and usage of your kit. It will not, however, exhaustively explain the underlying technology of the Synapse SNAP architecture or that of Exosite. If you wish to explore the technology further, this document will point you to additional resources where you can:

! Extend your wireless network by purchasing additional Synapse components from Arrow
Electronics and adding them to your Exosite cloud portal.

! Learn how to augment your Synapse ProtoBoards functionality by writing your own SNAPpy
scripts.

! Learn how to extend your Exosite cloud portals functionality by installing additional widgets and
writing your own Lua scripts.

! Learn how to build your own appliances and integrate them into your network using RF engines
from Synapse Wireless, and program them using the Synapse Portal software development environment. The Arrow M2M kits are available in three models, two of which are described by this document:

! EK2410EX This kit includes a Synapse SNAP Connect E10 and two Synapse SN171 SNAP
Node ProtoBoards, all equipped with Synapse RF100 RF engines.

! EK0910EX This kit includes a Synapse SNAP Connect E10 and two Synapse SN171 SNAP
Node ProtoBoards, all equipped with Synapse RF300 RF engines.

! EX2420EX This kit includes a Synapse SNAP Connect E10 and a Synapse SNAP Link
RS485, both equipped with Synapse RF100 RF engines, plus a Temco temperature monitoring unit.

Kit Contents
The two kits to which this document pertains contain identical contents with one exception:

! The Synapse RF100 modules in kit EK2410EX transmit at 2.4GHz. They include an external
antenna.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

1/29

! The Synapse RF300 modules in kit EK0910EX transmit at 900MHz. They do not use an
external antenna and instead rely on an integrated chip antenna. Otherwise the kits are identical. Please make note of which kit you have when assembling your ProtoBoards as the pinouts are slightly different.

EK2410EX Kit

EK0910EX Kit

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

2/29

Contents
! SNAP Connect E10 provides a gateway between the SNAP wireless network and the
internet.

! E10 Accessories wall mounting brackets, power supply, USB cable with micro connector on
the E10 side, ethernet cable, and antenna.

! SN171 SNAP Node ProtoBoards, quantify 2 the EK2410EX utilizes Synapse RF100 modules
and the EK0910EX utilizes Synapse RF300 modules.

! SN171 Accessories power supply, LEDs, resistors, thermistors, and photo cells. ! Exosite cloud account.

Download Supporting Materials


As mentioned above, this Quick Start guide is designed to aid you in getting your kit quickly setup and working. If you wish to dive deeper into the technology, there is extensive documentation available on both the Synapse Wireless and Exosite websites.

Synapse RF100 RF Engine


Product Brief
http://synapse-wireless.com/documents/products/Synapse-RF100xx-Engine-Product-Brief.pdf

Data Sheet
http://synapse-wireless.com/documents/products/Synapse-RF-Engine-RF100PC6-RF100PD6-DataSheet.pdf

Synapse RF300 RF Engine


Product Brief
http://synapse-wireless.com/documents/products/Synapse-RF300xx-Engine-Product-Brief.pdf

Data Sheet
http://synapse-wireless.com/documents/products/Synapse-RF300xx-Engine-Data-Sheet.pdf

SNAP Connect E10


Product Brief
http://synapse-wireless.com/documents/products/Synapse-SNAP-Connect-E10-Product-Brief.pdf

User Guide
http://synapse-wireless.com/documents/products/Synapse-SNAP-Connect-E10-User-Guide.pdf

Technical Manual
http://synapse-wireless.com/documents/products/Synapse-SNAP-Connect-E10-Technical-Manual.pdf

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

3/29

SNAP Software
We would like to welcome you to join the Synapse forum at this address: " http://forums.synapse-wireless.com/

Youll need to create a forum user name the rst time in, and then log in using your user name on subsequent visits. From the forum you can download hardware and software manuals. In particular, if this is your rst time experiencing SNAP, you might look at:

! SNAP Primer.pdf ! SNAPWhitePaper.pdf ! SNAP Reference Manual.pdf

Exosite Portal
" http://exosite.com/products/portals/documentation

In addition to the above documentation, when you create your Exosite account and log in, youll nd an extensive set of links to Exosite documentation everything from Exosite basics to developer APIs.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

4/29

Unpack, Assemble, Power Up


When your M2M kit arrives, unpack it and lay the components out in a manner similar to the photos above. Youll rst assemble the two ProtoBoards and power them up. Next youll hook the SNAP Connect E10 up to the internet and power it up.

Assemble the ProtoBoards


Your kit came with two ProtoBoards and an accessory pack of resistors, LEDs, thermistors, and photo sensors. The accessory pack with all parts laid out is shown below.

Your rst task is to connect these to the two ProtoBoards. Well use one each 10K ohm resistor (beige color), 100K ohm resistor (blue color), red LED, green LED, thermistor, and photo sensor in each board. The Synapse SN171 ProtoBoard provides easy access to all 19 General Purpose Input/Output (GPIO) pins available on the SNAP RF Engine. 8 of these pins (GPIO 11-18) can also serve as analog inputs. Make sure the screws in the terminal blocks are set to the open position (this should be the factory default). Like a standard screw, clockwise tightens and counter-clockwise will loosen the connector terminals.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

5/29

The SN171 ProtoBoard (without RF engine installed) is shown below.

All of the onboard RF Engine signals are made available at easy access screw terminal blocks located on either side of the node. These same signals are also made available in a more compact form in the center of the board. A single dual row header provides a connection point for a ribbon-cable (or some other form of wiring harness) from some other circuit board. The SN171 can be powered by an external power supply (5-9 VDC) or two AA batteries. Your kit came with the required external power supply. As noted previously, your kit came with two ProtoBoards containing either RF100 (2.4GHz) or RF300 (900MHz) Synapse RF engines. It is important to identify which you have as the pinouts between the two modules are slightly different. Determine which kit you have and follow the appropriate set of instructions below.

Assemble the EK2410EX with RF100 Module


Well use the pins on the left hand side of the ProtoBoard to connect the LEDs. Then well use the pins on the right side to connect the photo sensor, thermistor, and resistors.

! Before proceeding, ensure the ProtoBoard is not connected to power. ! Determine LED polarity Find the green LED. LEDs have a
polarity, so well need to determine which end is the negative terminal (the cathode). One of the legs of the LED should be shorter than the other. This is the negative leg. A at spot on the rim at the base of the colored bulb also indicates which side is the negative. This picture should help.

! Connect the green LED Place the negative leg of the green
LED into the terminal block at the pin labeled GPIO 3 (the fth pin from the top of the left-hand side of the ProtoBoard).

! Place the other leg of the green LED into the terminal block at the
pin labeled GPIO 0.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

6/29

! Tighten the screws located on the top of the terminal block for both GPIO pins. ! Connect the red LED Place the negative leg of the red LED into the terminal block at the pin
labeled GPIO 6 (near the middle of the left-hand side) of the ProtoBoard.

! Place the other leg of the red LED into the terminal block at the pin labeled GPIO 4. Note that
since this is not the adjacent slot on the connector you might have to bend (slightly) the legs of the LED.

! Tighten the screws located on the top of the terminal block for both GPIO pins. ! Connect the 10K ohm resistor Bend the legs of the beige resistor towards one another as
seen in the picture below.

! Place one resistor leg into the terminal block at the pin labeled GPIO 12 (the third pin up from
the bottom of the right-hand side) of the ProtoBoard.

! Place the other leg into the connector at GPIO 11. There is no polarity on this resistor, so it
does not matter which leg you choose for which pin.

! Tighten the screw for GPIO pin 12 only. This should lock the one leg of the resistor in place.
Well address the other leg in a moment.

! Connect the photo cell Place one leg of the photo cell
into the pin labeled GPIO 11 (dont worry it is supposed to share the connector with the resistor) and the other leg in the last slot in the connector (the GND pin). There is no polarity on the photo cell, so it does not matter which leg you choose for which pin.

! Tighten the associated screws and try a gentle tug on


the components. They should not move, but be rmly connected to the device.

! Carefully bend the photo cell so that the face of the


component points up.

! Connect the 10K ohm resistor (blue) to the ProtoBoard


Place one resistor leg into the terminal block at the pin labeled GPIO 18 (located on the right-hand side) of the ProtoBoard.

! Place the other leg into the connector at the pin labeled
VCC (located in the center of the right-hand side). There is no polarity on this resistor, so it does not matter which leg you choose for which pin.

! Tighten the screw for the VCC pin only. This should lock the one leg of the resistor in place.
Well address the other leg in a moment.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

7/29

! Connect the thermistor to the ProtoBoard Place one


leg of the thermistor (see picture for identication) into the pin labeled 18 (dont worry it is supposed to share the connector with the resistor) and the other leg in the rst slot in the connector (the GND pin). There is no polarity on the thermistor, so it does not matter which leg you choose for which pin. Notice how you have to bend the legs of the thermistor to reach across several connector slots.

! Tighten the associated screws.


Your rst ProtoBoard is now complete and your next task is to repeat this entire process with the second ProtoBoard. When complete, your EK2410EX ProtoBoards should look similar to this:

Assemble the EK0910EX with RF300 Module


Assembly of the EK0910EX is essentially the same as the EK2410EX, however the pinouts are different, hence our components are connected to alternate pins.

! Before proceeding, ensure the ProtoBoard is not connect to power. ! Determine LED polarity Find the green LED. LEDs have a
polarity, so well need to determine which end is the negative terminal (the cathode). One of the legs of the LED should be shorter than the other. This is the negative leg. A at spot on the rim at the base of the colored bulb also indicates which side is the negative. This picture should help.

! Connect the green LED Place the negative leg of the green
LED into the terminal block at the pin labeled GPIO 3 (the fth pin from the top of the left-hand side of the ProtoBoard).

! Place the other leg of the green LED into the terminal block at the
pin labeled GPIO 0.

! Tighten the screws located on the top of the terminal block for both GPIO pins.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

8/29

! Connect the red LED Place the negative leg of the red LED into the terminal block at the pin
labeled GPIO 6 (near the middle of the left-hand side) of the ProtoBoard.

! Place the other leg of the red LED into the terminal block at the pin labeled GPIO 4. Note that
since this is not the adjacent slot on the connector you might have to bend (slightly) the legs of the LED.

! Tighten the screws located on the top of the terminal block for both GPIO pins. ! Connect the 10K ohm resistor Bend the legs of the
beige resistor towards one another as seen in the picture.

! Place one resistor leg into the terminal block at the pin
labeled GPIO 15.

! Place the other leg into the connector at GPIO 16. There
is no polarity on this resistor, so it does not matter which leg you choose for which pin.

! Tighten the screw for GPIO pin 16 only. This should lock
the one leg of the resistor in place. Well address the other leg in a moment.

! Connect the photo cell Place one leg of the photo cell
into the pin labeled GPIO 15 (dont worry it is supposed to share the connector with the resistor) and the other leg in the last slot in the connector (the GND pin). There is no polarity on the photo cell, so it does not matter which leg you choose for which pin.

! Tighten the associated screws and try a gentle tug on the components. They should not move,
but be rmly connected to the device.

! Carefully bend the photo cell so that the face of the component points up. ! Connect the 100K ohm resistor (blue) to the ProtoBoard
Place one resistor leg into the terminal block at the pin labeled GPIO 9 (located on the left side) of the ProtoBoard.

! Place the other leg into the connector at the pin labeled
VCC (located in the center of the left side). There is no polarity on this resistor, so it does not matter which leg you choose for which pin.

! Tighten the screw for the VCC pin only. This should lock
the one leg of the resistor in place. Well address the other leg in a moment.

! Connect the thermistor to the ProtoBoard Place one leg of the thermistor (see picture for
identication) into the pin labeled 9 (dont worry it is supposed to share the connector with the resistor) and the other leg in the rst slot in the connector (the GND pin). There is no polarity on the thermistor, so it does not matter which leg you choose for which pin.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

9/29

! Tighten the associated screws.


Your rst ProtoBoard is now complete and your next task is to repeat this entire process with the second ProtoBoard. When complete, your EK0910EX ProtoBoard should look similar to this:

Power Up the ProtoBoards


When you are nished building both ProtoBoards, power them up by plugging them into the included power supplies. Go ahead and do that at this time. Within a second of plugging them in, you should see the small LED next to the power receptacle (labelled LED2) slowly ash yellow. This indicates normal operation. You can now set the ProtoBoards aside for the time being. Well revisit them when we turn our attention to the Exosite website.

Attach the E10 to the Internet


The next step is to power up and attach your SNAP Connect E10 to the internet.

! Using the included ethernet cable, attach your E10 to a known active
ethernet port that has a connection to the internet.

! Attach the included antenna to the E10s antenna port. ! Before applying power to your E10, ensure your two ProtoBoards
have been built up as previously described and are powered up. This is important because upon initial power up, the E10 will provision itself by searching out and identifying the two ProtoBoards.

! Finally, power-up the E10 by plugging in its AC adapter and then


stringing the included cable between the adapter (USB end) and E10 (micro USB end).

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

10/29

When you apply power to the E10 you should soon see both a green and amber LED, adjacent to and above the ethernet connector, illuminate. The amber LED will ash to indicate internet activity. If you do not see such activity, thats an indication the ethernet port to which youve attached your E10 is not currently active on the internet. If this should be the case, then please revisit that attachment and ensure the ethernet port you are using has an active internet connection. Finally, the LED labelled B, next to the ethernet port, should steadily glow green. The LED labelled A, other the other end of the E10, will not illuminate.

Conclusion
At this point your local area, wireless network is complete and ready to talk with Exosite. Using the Exosite web portal, youll be able to turn the LEDs on your ProtoBoards on and off, monitor the temperature sensed by the thermistor on your ProtoBoards, and monitor the ambient light level sensed by the photo sensor on your ProtoBoards. Youre now ready to proceed with the next section to setup your Exosite web portal.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

11/29

Congure Exosite
The Exosite web portal is a general purpose tool providing a cloud-based platform for connecting devices and software applications. The Exosite portal (not to be confused with the Synapse Portal software development software) manages and interacts with connected devices. In our case, those connected devices are the SNAP Connect E10 and your two ProtoBoards. To form the connection between Exosite and your Synapse wireless devices, we need to rst create an Exosite account (which comes with your M2M access kit) and then congure your devices.

Create an Exosite Account


Follow these steps to create your Exosite account:

! To create your Exosite account, point your web browser to:


! https://arrowm2mkits.exosite.com

! This takes you to the log in screen. To create


your account, click the link Dont have an account? Choose one and sign up now.

! This takes you to the pricing screen. Because


a starter account is complimentary with your M2M kit, click Sign Up Now under M2M Starter.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

12/29

! This then presents an account sign up form. Fill out the form and then press Create Account.

! Exosite will then create your account and send you an email message with which to validate
and complete account creation.

! Check your email and look for a message from arrowm2mkits.exosite.com. In the body of the
message, click the link to activate your account. Keep a copy of this message as it contains your activation key, in case you might need it again in the future.

! After clicking the link above, your web browser will then land on a Welcome page. Click the
login link, which takes you back to the main log in screen.

! Now log into your new account using the user name and password you entered when lling out
the account form. This completes the sign up process. You now have an active Exosite account and your next task will be to add your SNAP Connect E10 and ProtoBoards to the site. Before proceeding however, you might want to explore the site a little and start to become familiar with the layout. In particular, notice on the home screen a series of Useful Links which link to the Exosite documentation.

Congure your Synapse Modules


The following steps will guide you through the process of adding your Synapse devices to your Exosite portal. Well start with the E10 and then add the two ProtoBoards.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

13/29

Add the SNAP Connect E10 to Exosite


! If youre not already logged into Exosite, do that now by pointing your web browser to the
following address and then entering your email address and Exosite password. " https://arrowm2mkits.exosite.com

! From the Welcome screen, follow the instructions that appear in the Welcome window. Click
the Click here to add your kit devices to your Portal link.

! The next screen presents a popup list of all possible Synapse devices. It is important to choose
your devices from this list.

! The rst device you should setup is the E10. Choose SNAP Connect E10 from the list and
then click Continue.

! In the next screen, enter your E10s MAC address. This is printed on the bottom of your E10
and is 12 hex digits starting with 001C2C. Enter them as pairs separated by colons, as shown below. Note that the Exosite database contains a list of all known Synapse modules that have been included in the M2M access kits, so If you enter an invalid address Exosite will catch it and display an error.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

14/29

! Next give your device a name. In the example above, weve named it SNAP Connect E10. ! Clink Continue and you should then see a summary screen such as shown below:

! Click Quit to move on to the Devices page, which now looks like this:

Your SNAP Connect E10 is now congured into Exosite, so the next task is to add the two ProtoBoards.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

15/29

Add the Two ProtoBoards to Exosite


To add your two ProtoBoards to Exosite, youll need to execute the following steps twice, once for each of your two ProtoBoards.

! Start from the Devices screen, which we showed you above, and click the Add Device button
in the top right corner.

! This brings up the Add Device screen from which to choose the appropriate ProtoBoard. If you
have the EK2410EX kit, then you should choose SNAP Node ProtoBoard - RF100 (2.4GHz), as shown below:

If you have the EK0910EX kit, then you should choose SNAP Node ProtoBoard - RF300 (900MHz), as shown below:

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

16/29

! You will then be prompted to enter the devices MAC address.


Unlike previously, where we entered a 12-byte address for the E10, this time we only need to enter the last 6 bytes of the SNAP address. This can be found on the second line of text on the RF engine itself. In the example on the right, the SNAP address we would enter is 03DE80. The letters can be upper or lower case, it doesnt matter. For this step, do not use colons to separate the bytes.

! Next, give this device a name. In the example below, weve named
it ProtoBoard A.

! Click Continue to see a conrmation screen, and then click Quit to return to the Devices
page. Your Devices page, with SNAP Connect E10 and one ProtoBoard should now resemble the following.

Dont be concerned for now about the green / red indicators under the Active column. Exosite pings the E10 on a recurring basis, so after it has been connected for awhile its status will indicate Active. Since we just now congured the rst ProtoBoard, its status does not yet indicate Active. As soon as we issue a command to the ProtoBoard, which well soon do, its status will change to Active.

! Youve now completed setup your rst ProtoBoard and the next step is to do the same for the
second one. Go back to the rst step in this section and repeat these instructions to setup your second ProtoBoard.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

17/29

! Upon completion of this section, you should have your SNAP Connect E10 and two
ProtoBoards setup complete. Your Devices page should now resemble the following:

Conclusion
This concludes the setup of your Exosite web portal. Your Synapse nodes should now all be assembled, powered up, and congured into Exosite. Youre now ready to move on to the next section, where youll learn how to monitor your wireless, SNAP network devices from the Exosite web portal.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

18/29

Using Your Kit


At this point your Synapse devices should all be assembled and powered up. You should have created your Exosite web portal account and setup all your Synapse devices on it. If thats not the case, then please return to the applicable sections in this Quick Start Guide to accomplish those tasks before proceeding. This section gives a brief overview of the Exosite web portal and walks you through some the things you can do to monitor and control your Synapse wireless devices from the internet. This section does not cover everything you can do with Exosite. For a greater level of detail, please refer to the online documentation readily available on the Exosite portal.

Navigating Exosite Overview


Log onto Exosite by directing your web browser to the following address. " https://arrowm2mkits.exosite.com

When presented with the Log In screen, enter the email address and password you used when creating your account, then click the Log-In button.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

19/29

After logging in youll be on the Exosite home page, which will resemble the following.

Please note the following elements:

! The navigation menu is in the grey box in the upper left and is visible on every page. ! The Getting Started window in the top left provides useful links to the Exosite online
documentation.

! The My Devices / Kits window in the bottom left lists your Synapse devices. Since youve
already set these up, you should see your SNAP Connect E10 and two ProtoBoards in the list.

! If you click on one of those devices, youll then be taken to the Dashboard for that device.

Menu Items
Briey, here is a list of the navigation menu items that appear in the top left grey box, visible on every page.

! HOME Always takes you back to the home screen, displayed above. ! DATA For all devices, lists all the data that is being collected, last reported value, and last
reported collection time. This is described in further detail below.

! DEVICES Displays all your devices, their active status, last reporting time, and last reporting
event. This is the same screen you saw earlier, when adding your Synapse devices to Exosite.

! EVENTS For your two ProtoBoards, shows detailed information regarding events generated
by the devices. Presently, the only event implemented by the M2M access kits is a button push.

! DASHBOARDS This page allows you to setup your own dashboards. ! SCRIPTS Displays a list of Lua scripts which are running in your Exosite portal to interact with
your ProtoBoards.

! ADMIN This is a page to administer your Exosite account.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

20/29

ProtoBoard Data
Well next look at some of the interesting things you can do with Exosite and your ProtoBoards.

! Temperature Utilizing the thermistor, the two ProtoBoards report the current temperature to
Exosite on an ongoing basis.

! Button The ProtoBoards each have a small button on the connector end of the board. You
can push the button and Exosite will register the time the button was pushed and for how long it was held in.

! LEDs From Exosite, you can selectively turn the green and red LEDs on and off. ! Packet Whenever a ProtoBoard sends a packet of information to Exosite, its contents can be
viewed.

! Photo Cell Utilizing the attached photocell, the two ProtoBoards report the current ambient
light level to Exosite on an ongoing basis.

! Ping From Exosite you can ping your ProtoBoards. ! Signal Strength The ProtoBoards report their wireless signal strength to Exosite. This signal
strength is essentially the quality of wireless signal that exists between the ProtoBoards and the SNAP Connect E10. The closer they are in proximity, the greater the signal strength.

! Status ProtoBoard status is either active or not. Whenever a ProtoBoard is successfully


communicating with Exosite, its status will be reported as active.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

21/29

The Dashboard
Lets take a more detailed look at the dashboard. From the Home screen, click on one of your ProtoBoards listed in the My Devices / Kits window in the bottom left. This displays the dashboard screen, the top part of which is shown below:

Viewing the various windows, the one at the top left labelled Temperature - Past 24 Hours, does just what it says. It records the last 24 hours of temperature readings from the thermistor attached to your ProtoBoard. The next window, at the top right labelled Node, is a visual representation of your ProtoBoard. Superimposed on the picture are the values being reported by the thermistor, photo cell, and the state of the two LEDs. Next is the Temperature Gauge. This graphically displays the current temperature reported by the thermistor attached to your ProtoBoard. Next is Signal Strength - Past 4 Hours. This graphically indicates the strength of the wireless signal between your ProtoBoard and the SNAP Connect E10. You can experiment with that by moving your ProtoBoard further from the E10 to see how that effects the signal strength. Note that the device to be displayed is selected from the Select the device to show control at the top. In this example were looking at ProtoBoard A. Next, shown below is the bottom half of the dashboard page:

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

22/29

The top left window, labelled Photo Cell Value - Past 4 Hours, shows us a graph of the values reported by the photo cell attached to your ProtoBoard. You can experiment with this by covering up the photo cell with your nger or a piece of tape, and observing how the graph reacts. The next window, labelled Button Push Log, records an entry each time you press the small button on your ProtoBoard. This button is on the bottom of the board next to the large RS232 connector. The window in the bottom left corner, labelled Data reports the raw data as its reported by the ProtoBoard. Finally, the two small windows in the bottom right corner, labelled LED Control, are used to control the LEDs. Try clicking on these. You should see the control on the screen toggle and then after a short delay, you should see the LEDs on your ProtoBoard change accordingly.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

23/29

Data Page
Lets next look at the data page by clicking DATA in the grey menu box. While the Dashboard page gave us a nice visual representation of the data being reported by the ProtoBoards, this page displays the data in a raw form. The top portion of the data page, showing the data for one of the protoboards is shown below.

You can view any of the data elements in greater detail by clicking on it. From the resulting Data Information display you can then view, amongst many things, a graph over time and a log of the last 200 records. Finally, for data sources that can be controlled, such as the LEDs, you can write data to change their state.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

24/29

For example, clicking on Green LED brings up the following screen:

Under Write Data, if you type a 1 next to Data value: and then click Update. A command will be sent to your ProtoBoard to turn the green LED on. If you instead enter 0 and click Update, the LED will be turned off. When nished looking at this display, click the Close button in the bottom right corner to dismiss it and return to the Data page.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

25/29

Devices Page
We visited the Devices page earlier when adding your Synapse devices to your Exosite portal. Your completed Devices page should resemble the following:

Notice that now that the ProtoBoards are active, their device status is indicated as being On. Also notice the last time they sent a packet is reported as well as their last generated event. To get a more detailed view of device status, click on one of the ProtoBoards. In this example, we have clicked ProtoBoard A.

This page displays detailed information about your ProtoBoard and allows you to change certain elds, such as the device name. On the right side of the page is the current state of all the data items.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

26/29

Finally, at the bottom of the screen are a few additional controls to delete or re-enable a device.

Deleting a device permanently removes it from the Exosite portal. You likely will only need to use the re-enable command if you move a device from one Exosite account to another. Finally, the Close button in the bottom right closes the window, returning you to the Devices Page.

Conclusion
This completes our brief tour of Exosite and how it interacts with your Synapse Wireless components. We have only scratched the surface of what Exosite can do. To learn more, explore the documentation linked to the Getting Started window on the Home page as well as the link to the Exosite support page in the upper right corner of every page. We hope you have enjoyed setting up and exercising your Arrow M2M Access Kit.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

27/29

Regulatory Information And Certications


RF exposure statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

FCC certications and regulatory information (USA only)


FCC PART 15 CLASS B These devices comply with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) These devices may not cause harmful interference, and (2) These devices must accept any interference received, including interference that may cause harmful operation. RADIO FREQUENCY INTERFERENCE (RFI) (FCC 15.105) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

! Reorient or relocate the receiving antenna. ! Increase the separation between the equipment and receiver. ! Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.

! Consult the dealer or an experienced radio/TV technician for help.


LABELING REQUIREMENTS (FCC 15.19) This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

28/29

If the FCC ID for the module inside this product enclosure is not visible when installed inside another device, then the outside of the device into which this product is installed must also display a label referring to the enclosed module FCC ID.

Modications (FCC 15.21)


Changes or modications to this equipment not expressly approved by Synapse Wireless, Inc. may void the users authority to operate this equipment.

Declaration of Conformity
(In accordance with FCC 96-208 and 95-19) Manufacturers Name: ! Headquarters: ! ! Synapse Wireless, Inc. 500 Discovery Drive Huntsville, Al 35806

Synapse Wireless, Inc. declares that the product: Product Name ! SNAP Connect E10 (2.4GHz) ! SNAP Connect E10 (900MHz) ! SN171 ProtoBoard! RF100 w/SMA, 2.4GHz! RF300 w/Chip Ant, 900MHz ! Model Number SLE10-001 SLE10-900-001 200210-10 RF100PD6 RF300PC1

to which this declaration relates, meet the requirements specied by the Federal Communications Commission as detailed in the following specications:

! Part 15, Subpart B, for Class B equipment ! FCC 96-208 as it applies to Class B personal computers and peripherals
The products listed above have been tested at an External Test Laboratory certied per FCC rules and has been found to meet the FCC, Part 15, Emission Limits. Documentation is on le and available from Synapse Wireless, Inc.

Industry Canada (IC) certications


This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique nemet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la class B prescrites dans le Rglement sur le brouillage radioelectrique edicte par le ministre des Communications du Canada.

Arrow M2M Access Kits EK2410EX and EK0910EX Quick Start Guide!

29/29

Das könnte Ihnen auch gefallen