Sie sind auf Seite 1von 65

This structure is intended for less than 3 years of use.

Structures intended for more than 3 years of use should be desinged as permanent structures.

User Input Data Calculated Value Reference Data Designed By: Checked By: Company: Project Name: Project No.:
Site Location (City/Town) Sediment Basin Id. Total Drainage Area (acres) Raleigh 101 600

Date: Date:

Q10 (cfs)

100

Minimum pool elevation (ft) Maximum pool elevation (ft)

Disturbed acreage (ac) Min Volume (ft3) Sediment cleanout elevation (ft) Sediment Storage Area

Length/width ratio Is length/width ratio between 2-6? Basin surface area @ principal spillway (ft2) Ratio: basin surface area/Q10 Is ratio >= 435 ft2/cfs?

5 YES, PROCEED 0 NO, REVISE DESIGN

Weir coefficient, C Riser circumference, L (ft) Head above riser crest, H (ft) Qw (cfs)

Orifice coefficient, Co Riser cross-sectional area, A (ft2) Accleration due to gravity, g (ft/s2) Head above riser crest, H (ft) Discharge, Qo (cfs) 32.2 0

8.07a

Barrel diameter (ft) Barrel cross-sectional area, a (ft2) Accleration due to gravity, g (ft/s2) Head above outlet end of barrel, h (ft) Minor loss coefficieint, Km Barrel length, L (ft)

4 12.6

1.0

Mannings coeffienct of roughness, n Inside diameter of barrel, di (in) Pipe friction coefficient, Kp Discharge, Qo (cfs)

0.025 48 0.01823 0 0

Table 8.07b

Weight of water displaced by the empty riser Buoyant weight

Discharge velocity, V (ft/s) See Appendix 8.06 for riprap sizing, if necessary

8.07c

8.07d

Table 8.07c Table 8.07d

OPTION 1 Q10 Qp Emergency spillway capacity, Qe (cfs) Qp + Qe Does (Qp + Qe) equal or exceed Q10? 100 0 100 100 YES, PROCEED

Width of control section (ft) Width of entrance (ft) Slope of approach channel (%) Is width of the entrance section 1.5xcontrol section width? Is approach channel >/= 2%?

1.5 1.2 3 NO, REVISE DESIGN YES, PROCEED

CCMP=3.1

CCMP=0.6

Km=1.0 (typical)

nCMP=0.025 Table 8.07a

nRCP=0.015

OPTION 2 Weir coefficient, C Bottom width of spillway crest, L (ft) Depth of flow above spillway crest, H (ft) Emergency spillway capacity, Qe (cfs) 0 0 NO, REVISE DESIGN

Table 8.07a: Kp Values for Common Sizes of Pipe

Return to Main Worksheet

Table 8.07b: Design Chart for Riser Outlet

Return to Main Worksheet

Table 8.07c: Design Table for Vegetated Spillways Excavated in Erosion Resistant Soils

cavated in Erosion

Return to Main Worksheet

Table 8.07c: Design Table for Vegetated Spillways Excavated in Very Erodible Soils

cavated in Very Erodible

Return to Main Worksheet

Das könnte Ihnen auch gefallen