Structures intended for more than 3 years of use should be desinged as permanent structures.
User Input Data Calculated Value Reference Data Designed By: Checked By: Company: Project Name: Project No.:
Site Location (City/Town) Sediment Basin Id. Total Drainage Area (acres) Raleigh 101 600
Date: Date:
Q10 (cfs)
100
Disturbed acreage (ac) Min Volume (ft3) Sediment cleanout elevation (ft) Sediment Storage Area
Length/width ratio Is length/width ratio between 2-6? Basin surface area @ principal spillway (ft2) Ratio: basin surface area/Q10 Is ratio >= 435 ft2/cfs?
Weir coefficient, C Riser circumference, L (ft) Head above riser crest, H (ft) Qw (cfs)
Orifice coefficient, Co Riser cross-sectional area, A (ft2) Accleration due to gravity, g (ft/s2) Head above riser crest, H (ft) Discharge, Qo (cfs) 32.2 0
8.07a
Barrel diameter (ft) Barrel cross-sectional area, a (ft2) Accleration due to gravity, g (ft/s2) Head above outlet end of barrel, h (ft) Minor loss coefficieint, Km Barrel length, L (ft)
4 12.6
1.0
Mannings coeffienct of roughness, n Inside diameter of barrel, di (in) Pipe friction coefficient, Kp Discharge, Qo (cfs)
0.025 48 0.01823 0 0
Table 8.07b
Discharge velocity, V (ft/s) See Appendix 8.06 for riprap sizing, if necessary
8.07c
8.07d
OPTION 1 Q10 Qp Emergency spillway capacity, Qe (cfs) Qp + Qe Does (Qp + Qe) equal or exceed Q10? 100 0 100 100 YES, PROCEED
Width of control section (ft) Width of entrance (ft) Slope of approach channel (%) Is width of the entrance section 1.5xcontrol section width? Is approach channel >/= 2%?
CCMP=3.1
CCMP=0.6
Km=1.0 (typical)
nRCP=0.015
OPTION 2 Weir coefficient, C Bottom width of spillway crest, L (ft) Depth of flow above spillway crest, H (ft) Emergency spillway capacity, Qe (cfs) 0 0 NO, REVISE DESIGN
Table 8.07c: Design Table for Vegetated Spillways Excavated in Erosion Resistant Soils
cavated in Erosion
Table 8.07c: Design Table for Vegetated Spillways Excavated in Very Erodible Soils