Sie sind auf Seite 1von 2

Z-Brackets and QuickMount rail Powder coated covers

makes mounting and leveling provide a clean appearance


quick, safe, and easy. while protecting major
mechanical components.

– with autofill – with autofill and reset – with manual fill – with manual fill and reset
MECHANICAL BUILDING BLOCKS

– Direct (no mixing) – DMix – DMix Hybrid (high temp/DHW and mixed temp)

– DVIP (injection mixing) – DVIP Hybrid (high temp/DHW and mixed temp) – DVIP Injection with Zone Valves

SPECIAL
Open, single layer construction design means Modular design provides a unique
easy access to all major components. ability to customize any project.
– Heat exchanger snowmelt – Condensing boiler panel with zone valves – Geothermal panel

Quick installation with little to no


learning curve required. Large 1-1/4” main trunk line allows for
Z-Series panels are
available with or
without actuators.
Take the MYSTERY
out of the
applications with loads up to 200 MBH. An optional pressure
differential by-pass
valve is available for all
Z-Panels with actuators.
Designed for manual mixing, injection mixing, with

MECHANICAL ROOM
circulators, or with zone valves. HydroNex has the – Zone Direct (with actuators) – Zone Pump (with actuators) – Zone Mix Pump (with actuators)
right module for nearly every application.

USA: Canada:
All components are pre-wired and tested. Watts Radiant | 4500 E. Progress Place | Springfield, MO 65803 5435 North Service Road | Burlington, ONT L7L-5H7
CAT-5 cable connects one panel to the next. ph: 417.864.6108 800.276.2419 ph: 905.332.4090 888.208.8927
fax: 417.864.8161 | www.wattsradiant.com fax: 905.332.7068 888.882.1979 | www.wattscanada.ca

©Watts Radiant Lit#: 06-349-1526-57-02 Effective Date: 5/1/07


Why HydroNex?
• Fast installation
– Cut installation time and make more money!
• Simplify bids with fixed costs SPECIAL The Line-Up
• Easy maintenance 31
• Factory assembled and tested
17 18 20 1 Manual Fill Assembly
30 2 Temperature/Pressure Gauge
– HydroNex panels are guaranteed
3 Micro-Bubble Air Remover
to perform
19 4 Ball Valve
• Professional presentation 3 16 5 Expansion Tank Connection
• Performance engineered
6 AutoFill Assembly
• Plug-n-play CAT5 electrical connectors
7 Overflow Drain Line
– Reduce wiring and start up problems
8 Backflow Preventer
• Multiple panel configurations
• Proper piping and component placement 15 9 Primary Circulator
10 CAT-5 Connection
• Convenient purge assemblies & control valves 11 11 Relay Box
12 O-Ring Sealed Union
P-Series 4 13 Full Port Isolation Ball Valve
Primary panels circulate water through boilers, 21 14 Zone Circulator
remove air and provide essential service and 2 28
15 Isolation Valve
monitoring. Options include boiler reset controls 29 16 Check Valve
and auto-fill assemblies. 10 14 17 High Temperature Return
5 18 Zone Supply Line
D-Series 19 Zone Relay Box
Distribution panels send water to the point of 20 Zone Return Line
use. They provide temperatures that are high, 6 21 Injection Control
mixed or variable mixed. They service up to five 9 22 Injection Circulator
zones per board and can be linked together for 1 13 22 23 B-Line Strut Support
larger projects. 27 24 Gate Valve Balance Valve
25 25 Swing Check Valve
8 26 Sensor
S-Series 27 Metal Frame
Special Interest panels are designed for unique 32 33 28 Power Cord
applications, such as geothermal or condensing 29 Heat Exchanger
heat sources. S-Series panels can be used 30 Snowmelt Control
independently or with other HydroNex panels, 7 23 24 31 Leveling Adjustment
depending on the panel in question. 26 12 32 Supply From Boiler
33 Return to Boiler
Z-Series
Zone Panels include stainless steel manifolds to
distribute water to radiant circuits or other
equipment. They provide temperatures that are
high or mixed and are designed to be located in the HydroNex panels are the perfect solution for any radiant other. The only wiring required is to connect Best of all, each HydroNex panel is designed for HydroNex panels are available in a
zones they serve. wide range of configurations. Select
project: floor warming, heating, or snowmelting. Pre-piped, the zone thermostats to the corresponding easy system maintenance. Each component on the HydroNex panel, or panels, that
pre-wired, and factory tested with a professional relay terminal. the HydroNex panel can be easily accessed best fit your mechanical needs.
Some panel options include:
looking enclosure, these panels will dramatically reduce and isolated with numerous shut-off valves
installation times as well as virtually eliminate wiring and Connecting one panel to another is as easy located on all panels. - Primary with/without autofill
other start-up problems. as turning the hex nut on the brass o-ring - Primary with/without boiler reset
- Direct panel (no mixing)
seal union. Each union can withhold up to 100 Finally, each HydroNex comes with a finished - Injection mixing (with/without zone valves)
Each panel comes pre-wired with a 120 volt power psi when only hand tightened. white, powder coated cover to create that - Mix valve mixing (with/without zone valves)
- Condensing boilers
cord. Simply plug the HydroNex panel(s) into a standard perfect finished look. - Geothermal panels
wall outlet. The unique Z-Bracket hanging system - Heat exchanger panel for snowmelt systems
allows panels to be installed without the hazard So, don’t let your next radiant project slow
Condensing Boiler panel shown
Electrical connections are even easier with the CAT5 of trying to hold the panel while mounting. you down. HydroNex is fast, easy, and at left. This panel is designed as a
connection system. Control logic passes between panels Simply install the Z-Bracket on a wall and hang guaranteed to take the mystery out of stand alone panel with dedicated
domestic hot water capability.
though a CAT5 cable, enabling each panel to “talk” to each the HydroNex panel. That’s it! the mechanical room.