Channel and signalling unit E&M

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43082 AAXX

Function
This unit forms the interface between the internal bus of a 2 Mbit/s multiplexer and 15 audio channels with 1E&1M signalling.

Information for system configuration


CTC version : CTC3 Internal bus channels : As the unit is provided with a programmable CTC, the position of the unit on the subrack determines the unit address. The position of the channel signals on the internal buses and hence the bus channel numbers (from 1 to 15 and from 17 to 31) are determined by means of man-machine commands : 2 groups of bus channels are available for one CSU : 1 to 15 or 17 to 31; all channels on the same CSU must be connected to the same group; the position of each channel in the group is fixed : channel N on the CSU can thus be connected to bus channel N or (N+16); as soon as 1 channel on a CSU is allocated to a bus channel, the group is fixed (all other channels must be allocated to the same group); the number of channels that are used on each CSU is free : unused bus channels can be allocated by other CSU's.

Signalling type options : refer to the first appendix document : equipment layout. Correspondence between E- and M-wire status and signalling bits can be selected with straps, see strap options

Operational data
Audio : D D D D D D D 2-wire or 4-wire operation : selectable, see strap options nominal impedance : 600 input level 2-wire : -14 to +10 dBr input level 4-wire : -14 to +10 dBr output level 2-wire : -20 to +2 dBr output level 4-wire : -16 to +8 dBr adjustable in steps of 0,1 dB via man-machine commands, see section 3 of the manual : installation

Signalling : D E-wire inputs : - earth detector sensitivity : - should operate with 2 k - may not operate with 20 k - earth difference between exchange and CSU : max. +6 V D M-wire outputs : - current in M-wire to earth : max. 100 mA - voltage drop of M-wire (connected to battery) : max. 0,05 V / mA
DOCC: MMCC: *NA *NA 981016

3AL 43082 AAAA TNAAA Ed. 02

1/6

Front view

2x32-pin connector (D) (detail see next page)

2x32-pin connector (C) (detail see next page)

2/6

3AL 43082 AAAA TNAAA Ed. 02

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43082 AAXX

Channel and signalling unit E&M

Channel and signalling unit E&M


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43082 AAXX

Front connectors
Front connector C : audio input and output signals CA01 : A1MDF CA02 : C1MDF CA03 : A2MDF CA04 : C2MDF CA05 : A3MDF CA06 : C3MDF CA07 : A4MDF CA08 : C4MDF CA09 : A5MDF CA10 : C5MDF CA11 : Safety ground CA12 : A6MDF CA13 : C6MDF CA14 : A7MDF CA15 : C7MDF CA16 : A8MDF CA17 : C8MDF CA18 : A9MDF CA19 : C9MDF CA20 : A10MDF CA21 : C10MDF CA22 : Safety ground CA23 : A11MDF CA24 : C11MDF CA25 : A12MDF CA26 : C12MDF CA27 : A13MDF CA28 : C13MDF CA29 : A14MDF CA30 : C14MDF CA31 : A15MDF CA32 : C15MDF Meaning : AiMDF : A-wire access of channel i BiMDF : B-wire access of channel i CiMDF : C-wire access of channel i DiMDF : D-wire access of channel i i is 1 to 15 for the 15 channels on one unit. The channel signals are connected to the unit via multipair cables, terminated by means of multipin plugs, as indicated on the figure above. Cable code : 772 55066 CB01 : B1MDF CB02 : D1MDF CB03 : B2MDF CB04 : D2MDF CB05 : B3MDF CB06 : D3MDF CB07 : B4MDF CB08 : D4MDF CB09 : B5MDF CB10 : D5MDF CB11 : Safety ground CB12 : B6MDF CB13 : D6MDF CB14 : B7MDF CB15 : D7MDF CB16 : B8MDF CB17 : D8MDF CB18 : B9MDF CB19 : D9MDF CB20 : B10MDF CB21 : D10MDF CB22 : Safety ground CB23 : B11MDF CB24 : D11MDF CB25 : B12MDF CB26 : D12MDF CB27 : B13MDF CB28 : D13MDF CB29 : B14MDF CB30 : D14MDF CB31 : B15MDF CB32 : D15MDF

3AL 43082 AAAA TNAAA Ed. 02

3/6

Front connector D : signalling inputs and outputs DA01 : E1MDF DA02 : Safety ground DA03 : E2MDF DA04 : Safety ground DA05 : E3MDF DA06 : Safety ground DA07 : E4MDF DA08 : Safety ground DA09 : E5MDF DA10 : Safety ground DA11 : Safety ground DA12 : E6MDF DA13 : Safety ground DA14 : E7MDF DA15 : Safety ground DA16 : E8MDF DA17 : Safety ground DA18 : E9MDF DA19 : Safety ground DA20 : E10MDF DA21 : Safety ground DA22 : Safety ground DA23 : E11MDF DA24 : Safety ground DA25 : E12MDF DA26 : Safety ground DA27 : E13MDF DA28 : Safety ground DA29 : E14MDF DA30 : Safety ground DA31 : E15MDF DA32 : Safety ground Meaning : EiMDF : E-wire access of channel i MiMDF : M-wire access of channel i i is 1 to 15 for the 15 channels on one unit. The channel signals are connected to the unit via multipair cables, terminated by means of multipin plugs, as indicated on the figure above. Cable code :1 CSU : 772 55127 2 CSU : 772 55021 DB01 : M1MDF DB02 : Safety ground DB03 : M2MDF DB04 : Safety ground DB05 : M3MDF DB06 : Safety ground DB07 : M4MDF DB08 : Safety ground DB09 : M5MDF DB10 : Safety ground DB11 : Safety ground DB12 : M6MDF DB13 : Safety ground DB14 : M7MDF DB15 : Safety ground DB16 : M8MDF DB17 : Safety ground DB18 : M9MDF DB19 : Safety ground DB20 : M10MDF DB21 : Safety ground DB22 : Safety ground DB23 : M11MDF DB24 : Safety ground DB25 : M12MDF DB26 : Safety ground DB27 : M13MDF DB28 : Safety ground DB29 : M14MDF DB30 : Safety ground DB31 : M15MDF DB32 : Safety ground

4/6

3AL 43082 AAAA TNAAA Ed. 02

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43082 AAXX

Channel and signalling unit E&M

Channel and signalling unit E&M


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3AL 43082 AAXX

Strap options
For the location of the jumpers refer to figure 1. For each channel on the unit a selection is possible between 4-wire and 2-wire operation by means of the corresponding jumpers on Xi21 : D jumpers in position 1-2 and 3-4 : 4-wire operation; D jumpers in position 1-3 and 2-4 : 2-wire operation. Remark : i is 1 to 15 for the channels 1 to 15 on the unit. The correspondence between the E-wire status and the corresponding signalling bits can be selected by means of the switch S81 : D switch in position A : E-wires grounded make signalling bits 0; D switch in position B : E-wires grounded make signalling bits 1. The correspondence between the M-wire status and the corresponding signalling bits can be selected by means of the switch S42 : D switch in position A : signalling bits 0 make M-wires grounded; D switch in position B : signalling bits 1 make M-wires grounded. The TFC alarm can be enabled or disabled on the unit by means of the switch S1 : D switch in position A : TFC alarm enabled; D switch in position B : TFC alarm disabled. The status of the M-wires during TFC alarm (if enabled, see above) and power-up can be selected by means of the switch S58 : D switch in position A : M-wires open during TFC alarm and power-up; D switch in position B : M-wires grounded during TFC alarm and power-up.

3AL 43082 AAAA TNAAA Ed. 02

5/6

S81 S1

A A

B B A

2 1 4 3 2 1 4 3 B A A B S58 S42 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3

X121

X321

2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3

X221

X521

X421

X721

X621

X921

X821

X1121

X1021

X1321

X1221

X1521

X1421

Figure 1

Position of the straps on the board