Beruflich Dokumente
Kultur Dokumente
Expgui /GSAS
GSAS:
Allen C. Larson and Robert B. Von Dreele, Los Alamos National Laboratory, Los Alamos
Expgui:
Brian H. Toby, NIST Center for Neutron Research
Platforms:
Windows, Linux, SGI/Irix, Mac. Freeware for academic use
Download
CCP14 - Homepage: http://www.ccp14.ac.uk/solution/gsas/
CKWP13
0. Expgui /GSAS
CKWP13
0. Expgui /GSAS
A typical command line interface...
CKWP13
1. Setting up an experiment I
CKWP13
1. Setting up an experiment II
CKWP13
2. Adding a phase I
The Phase panel: Manual definition or import of supported crystallographic data formats
CKWP13
2. Adding a phase II
Always check for possible errors! Eg.: Here R-3c in hexagonal setting with centering vectors For rhombohedral setting: R -3 c R
CKWP13
CKWP13
CKWP13
After "Add" EXPTOOL automatically performs a check. Final display (no errors) will look like this:
CKWP13
CKWP13
CKWP13
LS Controls panel: Lowering the initial number cycles Check Extract Fobs Run POWPREF
CKWP13
Default Step back message after any changes (Switch off in options)
Last POWPREF run noted in history Everything ready for refinement: Run GENLES
CKWP13
Refinement of 7 parameters
CKWP13
Refinement of 7 parameters wRp: Chi: 99% => 72% 258 => 134 (Shifts insignificant if < esd)
CKWP13
Reflection tickmarks for each phase by 1, 2, .... (or Tickmarks in File) Fit becomes worse at higher angles!
CKWP13
CKWP13
CKWP13
10
CKWP13
Not necessary but: New GENLES fit: Chi drops to 60 (Better indexing)
CKWP13
11
Note: - Zero refinement preferably for parallel beam instruments (eg. synchrotron) - For parafocusing geometries (Bragg-Brentano): - Refinement of sample displacement - if needed also: Sample transparency
CKWP13
Zero shift changed: 0.04 -> 1.73 Means: 0.4 x 10-2 -> 1.73 x 10-2 degrees 2Theta (!)
CKWP13
12
Profile panel: Choose profile function Here: Gaussian with refinement of all three Cagliotti terms (U, V, W) Run GENLES
CKWP13
BUT: Model profiles truncated Reason: No POWPREF run after peak changes! Profiles became broader -> not enough data points in peak computation
CKWP13
13
Significant improvements for profiles at high angles Intensities still do not fit...
CKWP13
Here: Introduce a constraint Group atoms to share a common temperature factor (displacement parameter) Constraint panel -> New constraint
CKWP13
14
Constraints in Expgui: coordinates, displacement, profile parameters More constraints in EXPEDIT Set refinement flags for coordinates and displacement (X, U)
CKWP13
The result: Great impact on refinement: wRp goes down to 8% Chi goes down to 2
CKWP13
15
Here: Neutron data with regular peak shapes (!) 1) Apply individual displacement parameters (delete constraint)
CKWP13
CKWP13
16
Types: 1: Simple Gaussian peak shapes, poor asymmetry correction; appropriate for CW neutrons only. 2: Pseudo-Voigt function, poor asymmetry correction; good for refinements where low-angle peaks are not significant 3: Similar to type 2, except this includes the Finger-Cox-Jephcoat asymmetry correction. Good even with significant low angle peaks. 4: Similar to type 3, except this includes the Stephens model for anisotropic strain broadening (where different classes of reflections have different widths
CKWP13
CKWP13
17
CKWP13
CKWP13
18
CKWP13
19