Sie sind auf Seite 1von 4

BNWASBuyers Guide

1 WhenshouldyouplanforinstallingBNWAS? Variousindustrycommentatorshavehighlightedthatshipowners&operatorsshouldbeplanningnowfor installing BNWAS. BIMCO have advised their members to look to install at their vessels next drydocking insteadofwaitingforthelatestmandatoryinstallationdate. 2 HowimportantisBNWASTypeApproval? Very important if your fleet has ships of different class, it is wise to select a BNWAS Type Approved by each classification society of your ships. This will avoid the risk of a classification society rejecting BNWAS that is only approved by another society, or incurring additional certification costs that can be more than thecostoftheBNWASequipment. 3 HowimportantisittoconsidertotalinstalledCLASSAPPROVEDcostofyourchosenBNWAS? It is critical for you to consider the total installed cost of your chosen BNWAS as the hidden costs of installationaregenerallymuchmorethanthecostoftheBNWASequipmentitself.Itisadvisedtochoosea BNWASsystemthatoffersyoutheeasiestandquickestinstallationtosaveyourpreciousbudget. 4 Whatfeatureswillmaketheinstallationeasier,quickerandcheaper? 4.1 BNWAS that allows you to cable reset sensors and alarms directly to the control and alarm panel withouttheneedforaseparateandadditionalinterfacemodule 4.2 BNWASwithitsownbatterybackuptoavoidyouhavingtoinstallaseparateadditionalemergency powersupply 4.3 BNWASthatusesasinglecabletypebetweenallsensors,alarmsandcontrolpanel 4.4 BNWAS with integral motion sensor on the controller with no need for cabling remote sensors on smallerbridges 4.5 BNWAS that has an integral fault alarm so avoiding the requirement to buy and fit an additional faultalarmpanel 4.6 BNWAS that has an integral NMEA output to VDR so avoiding the requirement to buy and fit an additionalNMEAmodule 4.7 BNWAS that has screwed connectors so avoiding the requirement to arrange for soldered connections 4.8 BNWAS that is supplied as standard complete with all system and component brackets and bulkheadfixings;allsystemcableglands. 4.9 BNWAS that has integral alarm stage 1 bridge 85dB alarm sounder so avoiding the requirement to installandcableaseparateone 4.10 BNWASthatallowsdirectwiringtoPIRsoavoidingtherequirementforapatchcable,distribution box,andelectronicmodule. 4.11 BNWASthathasintegralofficercabinselectfacilityinsteadofrequiringyoutobuyandinstalla separatecabinselectorswitch 5 WhatBNWASmotionsensortypeshouldyouchose? 5.1 Sensorsthatusebothinfrared&microwavetechnologytopreventyoufromtheproblemsoffalse reset by airconditioning systems or objects moving on the bridge which affect conventional infra redmotionsensors.

5.2 6 6.1 6.2

Sensorsthatincorporatetemperaturecompensationtoprovideautomaticsensitivityadjustmentto preventthembeingineffectiveathighbridgetemperatures

WhatimportantadditionalfeaturesmightbeofvalueyoulookforinBNWAS? Datalogging of alarms in real time in the event of an incident you will need to understand what happenedonyourbridgeandadataloggingoptionwillprovideyouwithessentialevidence RS485 serial communications for connection to your VDR providing the highest possible degree of alarm/event logging and data security. This could be used as crucial evidence in an accident investigation. Extendedwarrantylookformaximum3YEARwarrantytermavailable Worldwidenetworkofapprovedsales,serviceandinstallationpartners BNWAS and supplier backed by a comprehensive reference list and positive testimonials from happycustomers Systemthatisbuilttolastonships BNWASthatenablesloggingofwhenthesystemisswitchedON&OFF Systemthatprovidesasecuremeansofpreventingthecrewswitchingitoff Forshipswithsmallbridgesafullselfcontainedsystemwithallfunctionsintegralinasinglebox

6.3 6.4 6.5 6.6 6.7 6.8 6.9

Help decide on your preferred BNWAS by using the following comparison table of key featuresofmanufacturerssystemsSEENEXTPAGE

BNWASMakersComparisonTable

KEYFEATURES BNWASTypeApprovedbyeach classificationsocietyofyourships? Cable directly to controller without separateinterfacemodule? Battery backup to avoid installing separateemergencypowersupply? Single cable type between all sensors,alarmsandcontrolpanel? Direct wiring to PIR with no patch cable,box,&electronicmodule? BNWAS with all functions integral in asinglebox(smallbridges) BNWASwithintegralfaultalarm? BNWASwithintegralNMEAoutput? BNWAS panel with integral cabin selector Supplied as standard with all bracketsfixings;cable&glands? BNWASintegralalarmstage1bridge 85dBalarmsounder? BNWAS sensors that use both infra red&microwavetechnology? Temp compensated motion sensors with&autosensitivityadjustment? BNWAS with password protection & nokeystolose? Datalogging of BNWAS alarms in realtime? RS485 serial communications for connectiontoyourVDR? Extended3yearwarranty? Worldwide network of sales, service andinstallationpartners? Robust construction system that is builttolastonships? Comprehensive references & happy customertestimonials? BNWASthatlogswhenthesystemis switchedON&OFF System that provides secure means ofpreventingcrewswitchingitOFF TotalYesscores

MAKERAnswerYES/NOtoeachfeature

Das könnte Ihnen auch gefallen