DESCRIPTION
DENISONs direct operated Directional Control Valve 4D01 conforms to Cetop 03 standard interface. They are designed to be subplate or manifold mounted or used in conjunction with the stack valves system (see also Bulletin 8-EN 565). Both the valve mounting interface and electrical connection methods available conform to the accepted International Standards Cetop, ISO and DIN. The five annuli body design gives a precise guide for many types of spools. High precision economical manufacturing processes allow interchangeability of spools without the need for selective assembly. For any applications which are not covered by the ordering code details, please contact your local DENISON office. The Directional Control 4D01 consists principally of a spool, body and either one or two actuators, depending on the application. The spool is shifted either by use of solenoids, mechanical actuator, hydraulic or pneumatic actuator, allowing oil under pressure from port P to flow to either port A or B, and subsequently connecting the alternate port to the tank. De-energizing the actuator allows the spring to return the spool to the centre or offset position. The manual override option allows for manual operation of the spool. In certain operating conditions a higher flow-volume can take place than the functional limit of the valve permits. In this case it is recommended to fit an orifice-plug in the P-port. For order details refer to page 3 or 4.
OPERATION
ORIFICE
4D01 .
1 2
.
3
..
4
..
5
..
6
B
7
...
9
..
0
..
1
..
2
..
3
..
4
Control 1 = 1 solenoid 2 = 2 solenoids 7 = 2 solenoids, 2 pos. detents (only for spools 11, 12, 51, 52 & 91) Spool Type refer to pages 5 and 6 Spool Position 01 = 2 (a, b), Spring offset to pos. b, energized to a 02 = 2 (a, b), Spring offset to pos. a, energized to b 03 = 3 (a, o, b), Spring centered pos. o 05 = 2 (o, b), Spring centered pos. o, energized to b 06 = 2 (o, a), Spring centered pos. o, energized to a 09 = 2 pos. detents (for control option 7) End Cap 01 = for control 1 02 = for controls 2, 7 Versions with inductive detector: SA = for control 1: neutral position controlled SB = for control 1: a or b position controlled TC = for control 2: a or b position controlled SC = for control 2: b or a position controlled TA = for control 2: o position controlled SA = for control 2: o position controlled Design Letter Seal Class 1 = NBR-seals (Standard) 4 = EPR-seals 5 = FPM-seals (Viton`) Solenoid Voltage W01 = 115 V / 60 W02 = 230 V / 60 W06 = 115 V / 50 W07 = 230 V / 50 Hz Hz Hz Hz G0R = 12 V G0Q = 24 V G0D = 27 V
For AC & DC sol. (see page 12) For DC sol. only (see page 13)
7 8
Order information for plug-in connectors see pages 9 or 10 1* Valve Accessories / Modifications 08 = Orifice 0.8 mm dia. in P-port 10 = Orifice 1.0 mm dia. in P-port 12 = Orifice 1.2 mm dia. in P-port 32 = Tube cartridge without manual override 52 = Tube cartridge with manual override and rubber cover G3 = Tube cartridge with manual override and soft shift orifice (only for DC version) see page 11
AC
DC
4D01 .
1 2
.
3
..
4
..
5
..
6
B
7
..
9
..
0
..
1
..
2
Control 4 = Lever operated 5 = Cam operated D = Pneumatic operation, one-side E = Pneumatic operation, both-sides F = Pneumatic operation, both-sides (2 pos. det.) Q = Hydraulic operation, one-side R = Hydraulic operation, both-sides S = Hydraulic operation, both sides (2 pos. det.) Spool Type refer to pages 5 and 6 Spool Position 01 = 2 (a, b), Spring offset to pos. b, activated to a 02 = 2 (a, b), Spring offset to pos. a, activated to b 03 = 3 (a, o, b), Spring centering pos. o 05 = 2 (o, b), Spring centering pos. o, activated to b 06 = 2 (o, a), Spring centering pos. o, activated to a 07 = 3 pos. detents (for control 4) 09 = 2 pos. detents (for control 4) End Cap 01 = for controls D and Q 02 = for controls E, F, R and S 04 = for controls 4 and 5 05 = for control 4 and spool pos. 07 and 09 Design Letter Seal Class 1 = NBR-seals (Standard) 4 = EPR-seals 5 = FPM-seals (Viton`)
7 8
SYMBOLS
q 1-Solenoid operation w pneumatic operation e hydraulic operation r Cam operation
B-Side
x 01 02 x 03 x 07 x 08 09 10 x 46 55 56 x 64 65 0X
x 11 x 12 x 51 52 81 91 0C 0Y
x 01 02 x 03 x 07 x 08 09 10 x 46 55 56 x 64 65 0X
SYMBOLS
q 1-Solenoid operation w pneumatic operation e hydraulic operation r Cam operation
q 2-Solenoid operation B-Side w pneumatic operation, both sides e hydraulic operation, both sides r Lever operation
Pressure bar
Flow l/min
Pressure bar
Flow l/min
Spool type 01 02 03 07 08 09 10 11 12 1) 46 51 52 55 56 64 65 81 91 0C 0Y 0X
CHARACTERISTICS
Design Type of mounting Mounting position Ambient temperature range Operating pressure (P, A, B) Max. flow Fluid Viscosity range Fluid temperature range Contamination level
Sliding spool valve Subplate Optional but horizontal optimal 20 . . . + 50 hC up to 350 bar 80 l/min (see diagrams) Mineral oil according to DIN 51524 and 51525 (For other fluids please consult DENISON) 10 . . . 650 cSt, optimal 30 cSt 18 . . . + 80 hC Max. permissible contamination level according to NAS 1638 Class 8 (Class 9 for 15 Micron and smaller) or ISO 17/14
If the performance characteristics outlined above do not meet your own particular requirements, please consult your local DENISON Office.
Nominal voltage Power input Permissible pressure T Solenoid response time sol. energized sol. de-energized quick energizing )
1
See ordering code page 3 31 W . . . . 210 bar . . . 46 ms . . . 27 ms . . . 30 ms + 5 . . . 10 % + 180 hC H 100 % IP 65 . . . 16.000 1.4 kg 1.7 kg
1)
double voltage
x x x x x x x
Permissible voltage difference max. coil temperature Temperature class Relative operating period Type of protection Cycle (1/ H) Weight 1 sol. 2 sol.
DC-Solenoid a
DC-Solenoid b
Manual override
Plug-in connectors according to ISO 4400 Port function P = Pressure T = Tank A + B = User Versions Standard < 250 V Seals for ports P, A, B, T 9.25 x 1.78 691-00012-0 PG 11 A-Side (grey) 167-01007-8 167-01100-8 167-01076-8 B-Side (black) 167-01008-8 167-01101-8 167-01014-8
36
Nominal voltage Power input Permissible pressure T Holding Inrush Solenoid response time sol. energized sol. de-energized Permissible voltage difference max. coil temperature Temperature class Relative operating period Type of protection Cycle (1/ H) Weight 1 sol. 2 sol.
See ordering code page 3 31 W . . . . 140 bar 78 VA 264 VA . . . 20 ms . . . 18 ms + 5 . . . 10 % + 180 hC H 100 % IP 65 . . . 7.200 1.5 kg 1.8 kg
x x x x x x x
AC-Solenoid a
AC-Solenoid b
Manual override
Plug-in connectors according to ISO 4400 Port function P = Pressure T = Tank A + B = User Versions Standard < 250 V Seals for ports P, A, B, T 9.25 x 1.78 691-00012-0 PG 11 A-Side (grey) 167-01007-8 167-01100-8 167-01076-8 B-Side (black) 167-01008-8 167-01101-8 167-01014-8
36
10
Venting
Venting
DC-sol. a
DC-sol. b
Circuit design
200
200
100
100
Example sol. a energized decompression PfA (t3): 300 bar; 60 l/min; 36 cSt; 50 hC; 4D01-3203-0302-B1 G0Q-G3
200
800
1000
200
800
1000
Response times (ms) for 24 V DC Solenoid t1 Spool stroke Pressure change 35...40 20...25 t2 55...60 35...40 t3 300...500 80...200 t4 400...800 80...400
Ordering code:
4D01 . . . . . . . . B . . .
G3
Solenoid voltage and current G0R = 12 VDC G0Q = 24 VDC G0H = 48 VDC With rectifier 1) DC-Output GAN = 102 VDC GAG = 205 VDC GAR = 98 VDC Modification G3 = soft shift
1 ) For applications with AC input voltage a DC solenoid with rectifier connector must be used!
Depending on spool type, the functional limits of the soft shift valve will be reduced with as much as 25 % in comparison to the data in this bulletin. Note: Ensure that the solenoid tube cartridges are filled with oil at all times. For that the tube cartridges have venting screws (see above). In applications above the oil level, the use of a check valve . . . 2 bar in the tank line is recommended.
11
x x
x x
Function Supply voltage US (full wave bridge with capacitor) Reverse polarity protection Ripple voltage Current consumption Outputs Out 1: Out 2:
P-channel FET, contact positive 24 V 20 % (19.2 V . . . 28.8 V) max. 300 V installed 10 % approx. 20 mA each circuit NC contact positive (not short circuit protection) NO contact positive US 2.5 V < 1.8 V < 400 mA at US + 20 % IP 65 0 hC . . . + 85 hC 4 x 0.5 mm2 p dyn. 315 bar 00 02 002 9 93
GND (pin 3)
Output voltage
Signal L Signal 0
Socket connector
US 24 VDC 20 %
Output current Environmental protection x Operating temperature range x Wire cross-sectional area x Tensile strength of transmitting conduit x Declaration of conformity no. Attention: EMC only ensured when using screened cables and screened plug casing!
x x
Example: 4D01-*1**-01SA-B*G0*
RL1, RL2 = e.g. coil resistance of the switch relay 60 without manual override 10 Nm
PG 7
DC-Solenoid a
Model Code (for AC & DC solenoids) 01, 06 Spool position 02, 05 4D01-*1**-02(05)SA-B 4D01-*1**-02(05)SB-B 4D01-*1**-01(06)SA-B 4D01-*1**-01(06)SB-B Example: US = 24 V; Signal L = 21.5 V; Signal 0 1.8 V 4D01-*1**-**SB Out 1
2.5 V Signal L sol. b energized Signal 0 Stroke 3 2 < 1.8 V 1 U (V) US Signal L sol. b energized Signal 0 Stroke 3 2 Signal L sol. b energized Signal 0 Stroke 1 3 U (V) US Signal L
Inductive detector on spool pos. a, o spool pos. a, o spool pos. o, b spool pos. o, b
Output signals neutral solenoid position energized Out 1 = L Out 1 = 0 Out 2 = 0 Out 2 = L Out 1 = L Out 1 = 0 Out 2 = 0 Out 2 = L Out 1 = L Out 1 = 0 Out 2 = 0 Out 2 = L Out 1 = L Out 1 = 0 Out 2 = 0 Out 2 = L
4D01-*1**-**SA Out 1
2.5 V U (V) US
4D01-*1**-**SA Out 1
U (V) US 2.5 V Signal L sol. a energized Signal 0
4D01-*1**-**SB Out 1
U (V) US 2.5 V Signal L sol. a energized Signal 0 < 1.8 V Stroke 2 3
sol. b energized Signal 0 Stroke 3 < 1.8 V 2 1 2.5 V U (V) US < 1.8 V 1 2
Stroke 3
Out 2
2.5 V
Out 2
Out 2
U (V) US Signal L sol. a energized Signal 0 Stroke 1 2 3 2.5 V US
Out 2
U (V) 2.5 V Signal L sol. a energized Signal 0 Stroke 2 3
< 1.8 V
< 1.8 V 2 1
< 1.8 V
< 1.8 V 1
12
Out 1 (pin 4)
Function Supply voltage US (full wave bridge with capacitor) x Reverse polarity protection x Ripple voltage x Current consumption x Outputs Out 1:
x x
P-channel FET, contact positive 24 V 20 % (19.2 V. . . 28.8 V) max. 300 V installed 10 % approx. 20 mA each circuit NC contact positive (not short circuit protection) NO contact positive US 2.5 V < 1.8 V < 400 mA at US + 20 % IP 65 0 hC . . . + 85 hC 4 x 0.5 mm2 p dyn. 140 bar 00 02 002 9 93
GND (pin 3)
Out 2:
x
Output voltage
Signal L Signal 0
Socket connector
US 24 VDC 20 %
Output current Environmental protection x Operating temperature range x Wire cross-sectional area x Tensile strength of transmitting conduit x Declaration of conformity no. Attention: EMC only ensured when using screened cables and screened plug casing!
x x
Example: 4D01-32**-03SC
without manual override 10 Nm PG 7
DC-Solenoid a
DC-Solenoid b
Spool position 03 Model Code (for DC solenoids only) 4D01-32**-03TC-B*G0* 4D01-32**-03SC-B*G0* 4D01-32**-03TA-B*G0* 4D01-32**-03SA-B*G0* Spool pos. monitoring aob end = a, b end = b, a neutral = o neutral = o Inductive detector on spool pos. a spool pos. b spool pos. a spool pos. b neutral position Output signals sol. b energized Out 1 = 0 Out 2 = L Out 1 = L Out 2 = 0 Out 1 = 0 Out 2 = L Out 1 = L Out 2 = 0 sol. a energized Out 1 = L Out 2 = 0 Out 1 = 0 Out 2 = L Out 1 = L Out 2 = 0 Out 1 = 0 Out 2 = L
Example: US = 24 V; Signal L = 21.5 V; Signal 0 1.8 V Monitoring neutral Position 4D01-32**-03SA 4D01-32**-03TA Out 1 Out 1
2.5 V US sol. a energized Signal 0 Stroke < 1.8 V Stroke Signal 0 Stroke < 1.8 V Stroke Stroke < 1.8 V U (V) Signal L US Signal L sol. b energized U (V) 2.5 V US sol. a energized Signal 0 Stroke Signal 0 Stroke < 1.8 V Stroke
4D01-32**-03TC Out 1
U (V) Signal L sol. b energized 2.5 V
Out 2
US Signal L
U (V)
Out 2
2.5 V US sol. b energized sol. a energized 2.5 V
U (V) Signal L US
Out 2
Signal L
U (V)
Out 2
2.5 V US sol. b energized sol. a energized 2.5 V
U (V) Signal L
Signal 0 Stroke
Signal 0 Stroke
13
Functional Limits (at 350 bar) Operating force Angle of operation Max. tank pressure Weight
60 l/min for spools 01, 02, 03, 08, 09, 10, 46, 55, 56, 0X 40 l/min for spools 07, 64, 65 30 N 17 h 160 bar 1.7 kg
x x x x
14
60 l/min for spools 01, 02, 03, 08, 09, 10, 11, 46, 51, 55, 56, 81, 91, 0C 10 l/min for spools 12, 52 35 l/min for spools 07, 64, 65, 0Y, 0X at tank pressure 0 bar neutral working stroke 135 N 155 N 175 N total stroke 195 N 195 N 195 N at tank pressure 20 bar neutral working stroke 160 N 180 N 200 N total stroke 220 N 220 N 220 N
at operating pressure
35 N 35 N 35 N 20 bar 1.4 kg
60 N 60 N 60 N
1
x x
15
60 l/min for spools 01, 02, 03, 08, 09, 10, 11, 46, 51, 55, 56, 81, 91, 0C 10 l/min for spools 12, 52 35 l/min for spools 07, 64, 65, 0Y, 0X
Pilot pressure tank pressure 0 bar tank pressure 160 bar max. allowed Tank pressure max. Pilot volume Response time 1) on off
1)
4 . . . 12 bar min. 4 bar min. 6 bar 12 bar 160 bar 3.2 cm3 50 . . . 200 ms 100 . . . 200 ms
x x x
16
60 l/min for spools 01, 02, 03, 08, 09, 10, 11, 46, 51, 55, 56, 81, 91, 0C 10 l/min for spools 12, 52 35 l/min for spools 07, 64, 65, 0Y, 0X
x x
160 bar min. 10 bar > tank pressure max. 210 bar pp 50 bar 50 . . . 100 ms 60 . . . 160 ms pp 200 bar 15 . . . 40 ms 60 . . . 160 ms
x x
17
For valves ordered without subplate, mounting screws must be ordered separately.
SUBPLATES
1 4
1 2
/ HH Subplate
44 (46)
d2 l 23 x 1 l 26 x 1 l 31 x 1
18
DESCRIPTION
DENISONs direct operated Directional Control Valve 4D02 conforms to Cetop 5 standard interface. It is designed to be subplate or manifold mounted and to be used in conjunction with the stack valve system (see also publication 8-EN 575). Both the valve mounting interface and electrical connection methods available conform to the accepted International Standards Cetop, ISO and DIN. The five annuli body design gives a precise guide for the spool throughout its stroke. For any application not covered by the ordering code details, please contact your local DENISON office. The Directional Control 4D02 consists principally of a spool, body, and either one or two actuators, depending on the application. The spool is shifted either by use of solenoids, mechanical or pneumatic actuator, allowing oil under pressure to flow from Port P to either port A or Port B and subsequently connecting the alternate port to tank. De-energizing the actuator allows the spring to return the spool to the centre or offset position. The manual override pin(s) at the end of the solenoid tubes allows manual operation of the spool. In certain operating conditions a higher flow can take place than the functional limit of the valve permits. In order to limit the flow through the valve it is recommended to fit an orifice-plug in the P-port. For order details refer to page 3 or 4.
OPERATION
ORIFICE
4D02 .
1 2
.
3
..
4
..
5
..
6
B
7
...
9
..
0
..
1
..
2
..
3
..
4
Series 02 = Cetop 05
Body 3 = Standard Body D = for Spool types 12 & 72 with AC-solenoid operation D = for Spool types 07, 64, 65 with AC & DC-solenoid operation D = for Soft Shift option G3 with DC-solenoid operation Control 1 = 1 solenoid 2 = 2 solenoid 7 = 2 solenoid, 2 pos. detents (only for spool types 11 and 51) Spool Type refer to pages 5 and 6 Spool Position 01 = 2 (a, b), Spring offset to pos. b, energized to a 02 = 2 (a, b), Spring offset to pos. a, energized to b 03 = 3 (a, o, b), Spring centered pos. o 05 = 2 (o, b), Spring centered pos. o, energized to b 06 = 2 (o, a), Spring centered pos. o, energized to a 09 = 2 pos. detents (for control option 7) End Cap 01 = for control option 1 02 = for control options 2 and 7 Versions with inductive detector: SA = for control 1: neutral position controlled SB = for control 1: a or b position controlled TC = for control 2: a or b position controlled SC = for control 2: b or a position controlled TA = for control 2: o position controlled SA = for control 2: o position controlled Design Letter Seal Class 1 = NBR-seals (Standard) 4 = EPR 5 = FPM-seals (Viton`) Solenoid Voltage W01 = 115 V / 60 W02 = 230 V / 60 W06 = 115 V / 50 W07 = 230 V / 50 Hz Hz Hz Hz G0R = 12 V G0Q = 24 V G0D = 27 V
7 8
AC
DC
1*
Valve Accessories / Modifications 16 = 1.6 mm orifice in P-port 20 = 2.0 mm orifice in P-port 25 = 2.5 mm orifice in P-port 32 = Tube cartridge without manual override 52 = Tube cartridge with manual override and rubber cover G3 = Soft Shift version with 0.8 mm orifice in channel-Z (only body type D with DC).
4D02 .
1 2
.
3
..
4
..
5
..
6
B
7
..
9
..
0
..
1
..
2
Series 02 = Cetop 05
Body 3 = Standard D = only for spools types 07, 64, 65 Control 4 = Lever operated 5 = Cam operated D = Pneumatic operation, one-side E = Pneumatic operation, both-sides F = Pneumatic operation, both-sides (2 pos. det.) Spool Type refer to pages 5 and 6 Spool Position 01 = 2 (a, b), Spring offset to pos. b, activated to a 02 = 2 (a, b), Spring offset to pos. a, activated to b 03 = 3 (a, o, b), Spring centering pos. o 05 = 2 (o, b), Spring centering pos. o, activated to b 06 = 2 (o, a), Spring centering pos. o, activated to a 07 = 3 pos. detents (for control 4) 09 = 2 pos. detents (for control 4) End Cap 01 = for controls D 02 = for controls E, F 04 = for controls 4 and 5 05 = for control 4 and spool pos. 07 and 09 Design Letter Seal Class 1 = NBR-seals (Standard) 4 = EPR 5 = FPM-seals (Viton`)
7 8
9.. Valve Accessories / Modifications 20 = 2.0 mm orifice in P-port 25 = 2.5 mm orifice in P-port
SYMBOLS
q 1-Solenoid operation w pneumatic operation e Cam operation
B-Side
SYMBOLS
q 1-Solenoid operation w pneumatic operation e Cam operation
Flow Q / l/min All performance data is recorded with port TA connected to tank. Additionally connecting also TB to tank, pressure drop can be reduced by 1.5 . . . 3 bar. Oil temperature 50 hC (122 hF); oil viscosity 40 cSt.
Spool Type
Flow Direction PA PB 1 3 3 12 3 3 3 5 4 1 5 6 7 6 3 11 5 4 9 10 7 15 5 10 6 12 9 11 AT 4 4 5 7 3 4 3 9 BT 10 7 8 13 6 6 9 11 13 PT 14
o-Position PA PB AT BT
b-Pos. a-Pos. PA PB
01 02 03 07 08 09 10 11 12 46 51 55 56 72 0M 0T AR
1 3 3 12 3 3 3 5 4 1 5 9 7 4 3 6 12
19
19
17
18 17
16
12 13
13 15 11
13 11
x x x x x x
140 l/min see diagrams Mineral oil according to DIN 51524 and 51525 (For other fluids please consult DENISON) 10 . . . 650 cSt, optimal 30 cSt 18 . . . + 80 hC Max. permissible contamination level confirming to NAS 1638 Class 8 (Class 9 for 15 Micron and smaller) or ISO 17/14
x x x
FUNCTIONAL LIMITS
The functional limits have been obtained with warm solenoid condition and at 10 % undervoltage from the selected nominal value. All flow data given is considered for 2 flow directions (e. g. PfB and simultaneously from AfT). For single flow direction (4-Way-Valve used as 3-Way-Valve) the permissible flow rates will be reduced by as much as 25 . . . 30 % in comparison to the data below.
03/08/0M/0T/AR
p / bar
/5 detent
p / bar
p / bar
/5 detent
Q / l/min
p / bar
Q / l/min
If the performance characteristics outlined above do not meet your requirements, please consult your local DENISON Office.
Nominal voltage Power input Solenoid response time sol. energized sol. de-energized Permissible voltage difference Max. coil temperature Temperature class Relative operating period Type of protection Cycle (1/H) Weight (1 solenoid version) (2 solenoid version)
x x x x x x x
DC Solenoid a
DC Solenoid b
Manual override
Nominal voltage Power input Holding (115 V / 60 Hz) Inrush (115 V / 60 Hz) Solenoid response time sol. energized sol. de-energized Permissible voltage difference Max. coil temperature Temperature class Relative operating period Type of protection Cycle (1/H) Weight (1 solenoid version) (2 solenoid version)
See ordering code on page 3 43 W 102 VA 518 VA . . . 25 ms . . . 18 ms + 5 % . . . 10 % + 180 hC H 100 % IP 65 . . . 6.500 4.4 kg 5.2 kg
x x x x x x x
Venting
AC Solenoid a
AC Solenoid b
Manual override
10
DC Solenoid a
DC Solenoid b
Pos. 1
Pos. 3
FUNCTIONAL LIMIT
With body option D and Soft Shift, the flow rating of the valve is reduced by approximately 25 % of the nominal value.
VENTING
Ensure that channel Z is filled with oil at all times (as delivered, the channel is prefilled with oil). Trouble-free operation of the valve can only be ensured when it is properly vented during the initial installation, and in case of service. To vent this valve, please use the following procedure: 1. Remove the vent port screws pos. 1 . . . 3. 2. Fill one of the vent ports with hydraulic fluid until this runs bubble free from the other vent ports. 3. Replace the vent port screws.
11
x x
x x
Function Supply voltage US (full wave bridge with capacitor) Reverse polarity protection Ripple voltage Current consumption Outputs Out 1: Out 2:
P-channel FET, contact positive 24 V 20 % (19.2 V . . . 28.8 V) max. 300 V installed 10 % approx. 20 mA each circuit NC contact positive (not short circuit protection) NO contact positive US 2.5 V < 1.8 V < 400 mA at US + 20 % IP 65 0 hC . . . + 85 hC 4 x 0.5 mm2 p dyn. 315 bar 00 02 002 9 93
GND (pin 3)
Output voltage
Signal L Signal 0
Socket connector
US 24 VDC 20 %
Output current Environmental protection x Operating temperature range x Wire cross-sectional area x Tensile strength of transmitting conduit x Declaration of conformity no. Attention: EMC only ensured when using screened cables and screened plug casing!
x x
Example: 4D02-*1**-03SA
RL1, RL2 = e.g. coil resistance of the switch relay 60 without manual override
DC = Solenoid a
Model Code (for AC & DC solenoids) 01, 06 Spool position 02, 05 4D02-*1**-02(05)SA-B 4D02-*1**-02(05)SB-B 4D02-*1**-01(06)SA-B 4D02-*1**-01(06)SB-B Example: US = 24 V; Signal L = 21.5 V; Signal 0 1.8 V 4D02-*1**-**SB Out 1
2.5 V Signal L sol. b energized Signal 0 Stroke 3 2 < 1.8 V 1 U (V) US Signal L sol. b energized Signal 0 Stroke 3 2 Signal L sol. b energized Signal 0 Stroke 1 3 U (V) US Signal L
Inductive detector on spool pos. a, o spool pos. a, o spool pos. o, b spool pos. o, b
Output signals neutral solenoid position energized Out 1 = L Out 1 = 0 Out 2 = 0 Out 2 = L Out 1 = L Out 1 = 0 Out 2 = 0 Out 2 = L Out 1 = L Out 1 = 0 Out 2 = 0 Out 2 = L Out 1 = L Out 1 = 0 Out 2 = 0 Out 2 = L
4D02-*1**-**SA Out 1
2.5 V U (V) US
4D02-*1**-**SA Out 1
U (V) US 2.5 V Signal L sol. a energized Signal 0
4D02-*1**-**SB Out 1
U (V) US 2.5 V Signal L sol. a energized Signal 0 < 1.8 V Stroke 2 3
sol. b energized Signal 0 Stroke 3 < 1.8 V 2 1 2.5 V U (V) US < 1.8 V 1 2
Stroke 3
Out 2
2.5 V
Out 2
Out 2
U (V) US Signal L sol. a energized Signal 0 Stroke 1 2 3 2.5 V US
Out 2
U (V) 2.5 V Signal L sol. a energized Signal 0 Stroke 2 3
< 1.8 V
< 1.8 V 2 1
< 1.8 V
< 1.8 V 1
12
Out 1 (pin 4)
Function Supply voltage US (full wave bridge with capacitor) x Reverse polarity protection x Ripple voltage x Current consumption x Outputs Out 1:
x x
P-channel FET, contact positive 24 V 20 % (19.2 V. . . 28.8 V) max. 300 V installed 10 % approx. 20 mA each circuit NC contact positive (not short circuit protection) NO contact positive US 2.5 V < 1.8 V < 400 mA at US + 20 % IP 65 0 hC . . . + 85 hC 4 x 0.5 mm2 p dyn. 140 bar 00 02 002 9 93
GND (pin 3)
Out 2:
x
Output voltage
Signal L Signal 0
Socket connector
US 24 VDC 20 %
Output current Environmental protection x Operating temperature range x Wire cross-sectional area x Tensile strength of transmitting conduit x Declaration of conformity no. Attention: EMC only ensured when using screened cables and screened plug casing!
x x
Example: 4D02-32**-03SC
without manual override
DC = Solenoid a
DC = Solenoid b
Spool position 03 Model Code (for DC solenoids only) 4D02-32**-03TC-B*G0* 4D02-32**-03SC-B*G0* 4D02-32**-03TA-B*G0* 4D02-32**-03SA-B*G0* Spool pos. monitoring a-o-b end = a, b end = b, a neutral = o neutral = o Inductive detector on spool pos. a spool pos. b spool pos. a spool pos. b Output signals sol. b energized Out 1 = 0 Out 2 = L Out 1 = L Out 2 = 0 Out 1 = 0 Out 2 = L Out 1 = L Out 2 = 0
neutral position
sol. a energized Out 1 = L Out 2 = 0 Out 1 = 0 Out 2 = L Out 1 = L Out 2 = 0 Out 1 = 0 Out 2 = L
Example: US = 24 V; Signal L = 21.5 V; Signal 0 1.8 V Monitoring neutral Position 4D02-32**-03SA 4D02-32**-03TA Out 1 Out 1
2.5 V US sol. a energized Signal 0 Stroke < 1.8 V Stroke Signal 0 Stroke < 1.8 V Stroke Stroke < 1.8 V U (V) Signal L US Signal L sol. b energized U (V) 2.5 V US sol. a energized Signal 0 Stroke Signal 0 Stroke < 1.8 V Stroke
4D02-32**-03TC Out 1
U (V) Signal L sol. b energized 2.5 V
Out 2
US Signal L
U (V)
Out 2
2.5 V US sol. b energized sol. a energized 2.5 V
U (V) Signal L US
Out 2
Signal L
U (V)
Out 2
2.5 V US sol. b energized sol. a energized 2.5 V
U (V) Signal L
Signal 0 Stroke
Signal 0 Stroke
13
120 l/min for spools 01, 03, 08 100 l/min for spools 07, 11, 51 60 l/min for spool 12 160 bar 30 N 5.2 kg
x x x
14
120 l/min for spools 01, 03, 08 100 l/min for spools 07, 11, 12, 51 at tank pressure 0 bar neutral working stroke 215 N 255 N 295 N total stroke 360 N 360 N 360 N at tank pressure 60 bar neutral working stroke 290 N 330 N 370 N total stroke 435 N 435 N 435 N
at operating pressure
1
x x
15
140 l/min for spool 46 100 l/min for spools 01, 02, 09, 10, 11, 51 80 l/min for spools 03, 08, 0M, 0T, AR 60 l/min for spools 07, 55, 56, 72 30 l/min for spool 12 Note: See curves on page 8 for functional limits below 315 bar
Pilot pressure tank pressure 0 bar tank pressure 160 bar max. allowed Tank pressure max. Pilot volume Response time 1) on off
1
4 . . . 12 bar min. 4 bar min. 6 bar 12 bar 160 bar 8.1 cm3 80 . . . 200 ms 120 . . . 200 ms
x x x
16
Subplate
( ) dimensions in brackets are for 3 /4 HH subplate
Mounting Configuration
M6 or 1 /4 HH-20 UNC (13 lg.)
All performance data is recorded with port TA connected to tank. Additionally connecting also TB to tank, pressure drop can be reduced by 1.5 . . . 3 bar.
Surface finish
0.8
For valves ordered without subplate, mounting screws must be ordered separately. 4 mounting screws M 6 x 40, DIN 912; 12.9
or
1 4
1 2
Torque 15 Nm
Weight 3 kg 3 kg
17
36
Versions Standard <250 V with LED (red) 15 . . . 30 V with bridge rectifier 12 . . . 250 V PG 11
18
Solenoid b
Solenoid a
SYMBOL
GENERAL
The DENISON 4D03 is a pilot operated directional control valve controlled by solenoids or hydraulic pressure. The 4D03 valve controls the flow direction in a hydraulic circuit. It delivers the performance demanded of modern hydraulic systems. Streamlined internal channels ensure minimum pressure drop at maximum flow. Subplate or manifold mount as standard.
CHARACTERISTICS
x x
Design Type of mounting Mounting position Ambient temperature range External pilot pressure (at 300 l/min) min max
Sliding spool valve Subplate according to CETOP 07, ISO 4401 Optional 20 . . . + 50 hC
x x x x
8.5 bar for spools with open center position 9.5 bar for spools with closed center position 250 bar > 250 bar . . . 350 bar a pilot orifice dia. .0 mm in P-port is recommended (code 10 or P3) 300 l/min (see diagrams) 300 . . . 650 ml/min (depends on spool type) Mineral oil according to DIN 51524 and 51525 (For other fluids please consult DENISON) 10 . . . 650 cSt, optimum 30 cSt 18 . . . + 80 hC Max. permissible contamination level according to NAS 1638 Class 8 (Class 9 for 15 Micron and smaller) or ISO 17/14
x x x
Max. flow Max. leakage Fluid Viscosity range Fluid temperature range Contamination level
x x x
ORDERING CODE
Model No.:
4D03 3
1
.
2
..
3
..
4
03
.
5
.
6
A
7
...
9
..
0
..
1
..
2
Series 03 = Cetop 07
Control A = Pilot operated, 1 solenoid (4D01) B = Pilot operated, 2 solenoids (4D01) C = Pilot operated, 2 solenoids (4D01) pilot valve: 2 pos. detents 0 = Hydraulic operation Spool Type refer to pages 5 and 6 Spool Position 01 = 2 (a, b ), Spring offset to pos. b, energized to a 02 = 2 (a, b ), Spring offset to pos. a, energized to b 03 = 3 (a, o, b), Spring centered pos. o 04 = 2 (a, b), Spool is not centered, energized to a or b (pilot valve with detents) 05 = 2 (o, b), Spring centered pos. o, energized to b 06 = 2 (o, a), Spring centered pos. o, energized to a Pilot Connection 0 = External PP, external PD (for control code) 1 = Internal PP, internal PD 1) 2 = Internal PP, external PD 1) 3 = External PP, internal PD 4 = External PP, external PD Main Valve Accessories 0 = without 1 = Shifting time adjustment 2 = Shifting time adjustment 6 = Shifting time adjustment 8 = Shifting time adjustment 4 = Integral check in P 1) Design Letter Seal Class 1 = NBR-seals (Standard) 4 = EPR-seals 5 = FPM-seals (Viton`) Solenoid Voltage W01 = 115 V / 60 W02 = 230 V / 60 W06 = 115 V / 50 W07 = 230 V / 50
(meter-in control) (meter-out control) (meter-in control) & integral check in P 1) (meter-out control) & integral check in P 1)
7 8
Hz Hz Hz Hz
Order information for plug-in connectors see page 13 1* Pilot Accessories / Modifications 10 = 1.0 mm orifice in P-port; for solenoid with manual override 1032 = 1.0 mm orifice in P-port; for solenoid without manual override 1052 = 1.0 mm orifice in P-port; for solenoid with manual override; with rubber cover P3 = 1.0 mm orifices in A & B-ports of the cap; for hydraulic operation only (control code 0)
1)
AC
DC
Note: For valves with no-load flow (spools 0, 07) and internal PP an integral check is recommended in P-port of the main body to obtain the minimum pilot pressure. The integral check is not provided for load pressure holding back to P-port.
Pressure Drop Spool Type 01 Spool Type 07 Spool Type 10 Spool Type 46
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
Spool Type 02
Spool Type 08
Spool Type 13
Spool Type 55
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
Spool Type 03
Spool Type 09
Spool Type 14
Spool Type 56
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
Spool Type 11
Spool Type 51
p / bar
Q / l/min
p / bar
Q / l/min
Functional Limits Spool Type 01, 02, 03, 08, 09, 10, 13, 14, 46, 55, 56 07 11 51 70 300 300 300 300 max. Flow (l/min) versus Pressure (bar) 140 210 280 350 300 300 300 300 280 300 300 230 300 180 * The fail safe flow limits of the spool types 11 & 51 must be reduced at higher operating pressure to comply with safety regulations where applicable. Means: The main spool returns to spring offset position only by spring force (without pilot pressure).
300/200* 300/190*
B-Side
q w
x 01
x 01
x 01
x 02
x 02
x 02
x 03
x 03
x 03
x 07
x 07
x 07
x 08
x 08
x 08
x 09
x 09
x 09
x 10
x 10
x 10
13
13
13
14
14
14
46
46
46
x 55
x 55
x 55
x 56
x 56
x 56
x 11
x 11
x 51
x 51
DETAILED SYMBOLS
4D03 3 A51 0103 40A. ... Spool Position 01 2 (a, b), Spring Offset
Pilot 4D01 3 151 0101 B. ...
4D03 3 A51 0203 40A. ... Spool Position 02 2 (a, b), Spring Offset
Pilot 4D01 3 151 0201 B. ...
X-external 4D03 3 B.. 0303 40A. ... Spool Position 03 3 (a, o, b), Spring Centering
Y-external
X-external 4D03 3 C.. 0403 40A. ... Spool Position 04 2 (a, b), Pilot Valve with detents
Y-external
X-external 4D03 3 A.. 0503 40A. ... Spool Position 05 2 (o, b), Spring Centering
Y-external
X-external 4D03 3 A.. 0603 40A. ... Spool Position 06 2 (o, a), Spring Centering
Y-external
X-external
Y-external
X-external
Y-external
1)
AC
x x x x x
x x x x x
Nominal voltage Power input Permissible tank pressure (T) with internal drain with external drain Permissible drain pressure (Y) Holding Inrush Permissible voltage difference Response times (at 200 l/min & without pilot orifice) energized at 50 bar at 150 bar at 250 bar de-energized at 50 bar at 150 bar at 250 bar Max. coil temperarature Temperature class Relative operating period Type of protection Weight 1 solenoid version 2 solenoid version
See ordering code on page 4 31 W 31 W up to 210 bar up to 350 bar up to 210 bar + 5 % . . . 10 % up to 140 bar up to 350 bar up to 140 bar 78 VA 264 VA + 5 % . . . 10 %
198 AC (240) 222.4 = DC (243.4) ( ) dimensions in brackets are for version with rubber cover 144 AC (165) 156.2 = DC (166.7) Manual override
DC-sol. b
DC sol. a
HYDRAULIC OPERATION
x
e.g. 50 ms with pilot flow 6.5 l/min e.g. 40 ms pressureless return line . . . 350 bar 8.2 kg
OPTIONS
Version with shifting time adjustment
1.3 kg
Pilot connections
Flow Q / l/min Note: For valves with no-load flow (spools 0, 07) and internal PP an integral check is recommended in P-port of the main body to obtain the minimum pilot pressure. The integral check is not provided for load pressure holding back to P-port.
10
Block mounting face Flatness 0.01 mm/100 mm length Surface finish 0.8
Portings P = Pressure port T = Tank port A & B = Actuator ports X = Pilot port for external PP: pilot operated valves = Pilot port for hydr. operated valves Y = Drain port for external PD: pilot operated valves = Pilot port for hydr. operated valves
11
SUBPLATES
Weight: 3.5 kg
Weight: 8.3 kg
Please note: Mounting screws are included in subplate order. For valves ordered without subplate, mounting screws must be ordered separately. Mounting screws (4) M 10 x 65 DIN 912; 10.9 (2) M 6 x 65 DIN 912; 10.9 Torque 50 Nm for M10 13 Nm for M6 Order-No. 700714498 700701058
Model-No.
Order-No.
d5 M 10 M 10
d6 M6 M6
12
36
Versions Standard <250 V with LED (red) 15 . . . 30 V with bridge rectifier 12 . . . 250 V PG 11
The product described is subject to continual development and the manufacturer reserves the right to change the specifications without notice.
13
SYMBOL
GENERAL
The DENISON 4D06 is a pilot operated directional control valve controlled by solenoids or hydraulic pressure. The 4D06 valve controls the flow direction in a hydraulic circuit. It delivers the performance demanded of modern hydraulic systems. Streamlined internal channels ensure minimum pressure drop at maximum flow. Subplate or manifold mount as standard.
CHARACTERISTICS
x x
Design Type of mounting Mounting position Ambient temperature range External pilot pressure (at 700 l/min) min max
Sliding spool valve Subplate according to CETOP 08, ISO 4401, DIN Optional 20 . . . + 50 hC
x x x x
9 bar for spools with open center position 10 bar for spools with closed center position 250 bar > 250 bar . . . 350 bar a pilot orifice dia. .0 mm in P-port is recommended (code 10 or P3) DC-solenoid: up to 210 bar AC-solenoid: up to 140 bar up to 350 bar
Permissible tank pressure (T) with internal drain with external drain
Permissible drain pressure (Y) DC-solenoid: up to 210 bar AC-solenoid: up to 140 bar Max. flow Max. leakage Fluid Viscosity range Fluid temperature range Contamination level 700 l/min (see diagrams) 350 . . . 900 ml/min (depends on spool type) Mineral oil according to DIN 51524 and 51525 (For other fluids please consult DENISON) 10 . . . 650 cSt, optimum 30 cSt 18 . . . + 80 hC Max. permissible contamination level according to NAS 1638 Class 8 (Class 9 for 15 Micron and smaller) or ISO 17/14
x x x
x x x
ORDERING CODE
Model No.:
4D06 3
..
..
03
...
..
..
..
Series 06 = Cetop 08 Control A = Pilot operated, 1 solenoid (4D01) B = Pilot operated, 2 solenoids (4D01) C = Pilot operated, 2 solenoids (4D01) pilot valve: 2 pos. detents 0 = Hydraulic operation Spool Type refer to pages 5 and 6 Spool Position 01 = 2 (a, b ), Spring offset to pos. b, energized to a 02 = 2 (a, b ), Spring offset to pos. a, energized to b 03 = 3 (a, o, b), Spring centered pos. o 04 = 2 (a, b), Spool is not centered, energized to a or b (pilot valve with detents) 05 = 2 (o, b), Spring centered pos. o, energized to b 06 = 2 (o, a), Spring centered pos. o, energized to a Pilot Connection 0 = External PP, external PD (for hydraulic operation) 1 = Internal PP, internal PD 1) 2 = Internal PP, external PD 1) 3 = External PP, internal PD 4 = External PP, external PD Main Valve Accessories 0 = without 1 = Shifting time adjustment 2 = Shifting time adjustment 6 = Shifting time adjustment 8 = Shifting time adjustment 4 = Integral check in P 1) Design Letter Seal Class 1 = NBR-seals (Standard) 5 = FPM-seals (Viton`) Solenoid Voltage W01 = 115 V / 60 W02 = 230 V / 60 W06 = 115 V / 50 W07 = 230 V / 50 Hz Hz Hz Hz G0R = 12 V G0Q = 24 V G0D = 27 V
(meter-in control) (meter-out control) (meter-in control) & integral check in P 1) (meter-out control) & integral check in P 1)
Order information for plug-in connectors see page 13 Pilot Accessories / Modifications 10 = 1.0 mm orifice in P-port; for solenoid with manual override 1032 = 1.0 mm orifice in P-port; for solenoid without manual override 1052 = 1.0 mm orifice in P-port; for solenoid with manual override; with rubber cover P3 = 1.0 mm orifices in A & B-ports of the cap; for hydraulic operation only (control code 0)
1)
AC
DC
Note: For valves with no-load flow (spools 0, 07) and internal PP an integral check is recommended in P-port of the main body to obtain the minimum pilot pressure. The integral check is not provided for load pressure holding back to P-port.
Pressure Drop Spool Type 01 Spool Type 07 Spool Type 10 Spool Type 46
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
Spool Type 02
Spool Type 08
Spool Type 13
Spool Type 55
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
Spool Type 03
Spool Type 09
Spool Type 14
Spool Type 56
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
p / bar
Q / l/min
Spool Type 11
Spool Type 51
p / bar
Q / l/min
p / bar
Q / l/min
Functional Limits Spool Type 02, 03, 08, 09, 10 13, 14, 46, 55, 56 01 07 11 51 70 700 700 700 700 700 max. Flow (l/min) versus Pressure (bar) 140 210 280 350 700 700 700 700 * The fail safe flow limits of the spool types 11 & 51 must be reduced at higher operating pressure to comply with safety regulations where applicable. Means: The main spool returns to spring offset position only by spring force (without pilot pressure).
700 700 680 600 670 590 510 430 700 700/630* 700/515* 700/400* 700/620* 700/480* 700/340* 700/200*
B-Side
q w
x 01
x 01
x 01
x 02
x 02
x 02
x 03
x 03
x 03
x 07
x 07
x 07
x 08
x 08
x 08
x 09
x 09
x 09
x 10
x 10
x 10
13
13
13
14
14
14
46
46
46
x 55
x 55
x 55
x 56
x 56
x 56
x 11
x 11
x 51
x 51
DETAILED SYMBOLS
4D06 3 A51 0103 40A. ... Spool Position 01 2 (a, b), Spring Offset
Pilot 4D01 3 151 0101 B. ...
4D06 3 A51 0203 40A. ... Spool Position 02 2 (a, b), Spring Offset
Pilot 4D01 3 151 0201 B. ...
X-external 4D06 3 B.. 0303 40A. ... Spool Position 03 3 (a, o, b), Spring Centering
Y-external
X-external 4D06 3 C.. 0403 40A. ... Spool Position 04 2 (a, b), Pilot Valve with detents
Y-external
X-external 4D06 3 A.. 0503 40A. ... Spool Position 05 2 (o, b), Spring Centering
Y-external
X-external 4D06 3 A.. 0603 40A. ... Spool Position 06 2 (o, a), Spring Centering
Y-external
X-external
Y-external
X-external
Y-external
1)
AC on page 4 31 W 78 VA 264 VA + 5 % . . . 10 %
x x x x x
Nominal voltage Power input Holding Inrush Permissible voltage difference Response times (at 400 l/min & without pilot orifice) energized at 50 bar at 150 bar at 250 bar de-energized at 50 bar at 150 bar at 250 bar Max. coil temperature Temperature class Relative operating period Type of protection Weight 1 solenoid version 2 solenoid version
198 AC (240) 222.4 = DC (243.4) 144 AC (165) 156.2 = DC (166.7) Manual override
DC-sol. b
DC-sol. a
HYDRAULIC OPERATION
x
e.g. 100 ms with pilot flow 6.5 l/min e.g. 80 ms with pressureless return line 16.3 kg
OPTIONS
Version with shifting time adjustment
1.3 kg
Pilot connections
For flow lower than 450 l/min an Integral Check should be applied (see Note). Integral Check Pressure drop p / bar
Flow Q / l/min Note: For valves with no-load flow (spools 0, 07) and internal PP an integral check is recommended in P-port of the main body to obtain the minimum pilot pressure. The integral check is not provided for load pressure holding back to P-port.
10
MOUNTING CONFIGURATION
Mounting configuration according to CETOP, ISO and DIN
Block mounting face Flatness 0.01 mm/100 mm length Surface finish 0.8
Portings P = Pressure port T = Tank port A & B = Actuator ports X = Pilot port for external PP: pilot operated valves = Pilot port for hydr. operated valves Y = Drain port for external PD: pilot operated valves = Pilot port for hydr. operated valves
NBR-Seals A, B, T P X, Y 28.17 x 3.53 31.34 x 3.53 20.29 x 2.62 691002160 691002180 691001170
11
Weight: 8 kg
Please note: Mounting screws are included in subplate order. For valves ordered without subplate, mounting screws must be ordered separately.
Qty. 6
Order-No. 361-12293-8
Torque 103 Nm
d3 M 12 M 12
l1 55 48.5
l2 49 59.5
l3 66 62
l4 90 82
Panel opening
12
36
Versions Standard <250 V with LED (red) 15 . . . 30 V with bridge rectifier 12 . . . 250 V PG 11