716, Chenoy Trade Centre Parklane, S.D. Road, Secunderabad 500 003.
Tel: 040-27816524, 27898013 Fax: 040- 27896481
E-mail: info@indochem.in
Website: www.indochem.in
PARAMETERS
pH
:
Conductivity
s/cm :
T.D.S (ppm)
:
Total Hardness
(ppm as Ca Co3)
:
P. Alkalinity
(ppm as CaCo3)
:
M. Alkalinity
(ppm as Ca Co3)
:
T. Chlorides
(ppm as CI)
:
Ca.Hardness
(ppm as CaCo3 )
Silica (ppm as
SiO2 )
Scaling
tendency(%)
Compress
or bore-1
Water
ADM
Bore-2
Water
Process
In water
Process
Out-A
Water
7.46
Huts
FrontBore-3
Water
7.00
7.04
7.72
7.66
656
722
728
493
516
432
476
480
325
340
248
241
268
142
146
NIL
NIL
NIL
NIL
NIL
260
270
274
129
145
39
44
46
39
41
146
142
159
85
85
4.52
7.89
17.3
7.78
13.6
2.74%
Mfrs: of Water Treatment Chemicals, Plants, Water Testing Kits and O&M Services
Customer Care Center:
Hyderabad, Vijayawada - 9440803615, Rajahundry 9440804537, Vizag 9440803611, Bellary-9440803612,
Faridabad - 9493174548
INDOCHEM TECHNOLOGIES
716, Chenoy Trade Centre Parklane, S.D. Road, Secunderabad 500 003.
Tel: 040-27816524, 27898013 Fax: 040- 27896481
E-mail: info@indochem.in
Website: www.indochem.in
PARAMETERS
pH
:
Conductivity
s/cm :
T.D.S (ppm)
:
Total Hardness
(ppm as Ca Co3)
:
P. Alkalinity
(ppm as CaCo3)
:
M. Alkalinity
(ppm as Ca Co3)
:
T. Chlorides
(ppm as CI)
:
Ca.Hardness
(ppm as CaCo3 )
Silica (ppm as
SiO2 )
Scaling Tendency
(%)
Process
Out-B
Water
7.68
CT-INA
Water
7.36
CT-INB
Water
7.30
Discharge
End of Sump
water
7.02
507
751
701
636
334
495
462
419
139
261
234
187
NIL
NIL
NIL
NIL
125
278
250
169
46
44
41
26
81
156
139
112
19.4
9.05
16.4
7.82
2.63%
0.62%
Mfrs: of Water Treatment Chemicals, Plants, Water Testing Kits and O&M Services
Customer Care Center:
Hyderabad, Vijayawada - 9440803615, Rajahundry 9440804537, Vizag 9440803611, Bellary-9440803612,
Faridabad - 9493174548
INDOCHEM TECHNOLOGIES
716, Chenoy Trade Centre Parklane, S.D. Road, Secunderabad 500 003.
Tel: 040-27816524, 27898013 Fax: 040- 27896481
E-mail: info@indochem.in
Website: www.indochem.in
Comments
We analyzed the water sample and submit the report as above.
1. Samples CT-IN-A and CT-IN-B(Which Are In Let and Out Let of
Cooling Tower) indicate the scale formation in the system
(Nozzles) in Ct Water about 0.7% scaling in one cycle , because
the spry water is directly contacting the dust particles in the
cooling tower, scale is in the suspended and dissolved form.
(Report you can Observe)
2. Regarding the process water the samples of process in water
is (Inlet to the Compressors and Mill cooling) and process outA, Process out B are out let of the same system. Across the
system there is scaling is observed about 3% in one cycle.
3. The bore water sample are observed and ranked as
compressor bore-1, and Discharge end of sump water are good
as compared to the other bores. (As compared to Silica TDS
and total hardness).
4. To resolve the problem of Scaling and deposition is possible by
installing a side stream filter and a softener or a reverse
Osmosis system.
5. The cost of water by treating with softener will be
approximately Rs. Rs.3/1Kl of Water
6. The Cost of water by treating with Reverse Osmosis will be
Rs.5/KL
For INDOCHEM TECHNOLOGIES
Q.C. In charge.
Mfrs: of Water Treatment Chemicals, Plants, Water Testing Kits and O&M Services
Customer Care Center:
Hyderabad, Vijayawada - 9440803615, Rajahundry 9440804537, Vizag 9440803611, Bellary-9440803612,
Faridabad - 9493174548