Sie sind auf Seite 1von 2

IRIS Instruments - 1 avenue BuIIon, B.P.

6007, 45060 Orleans Cedex 2, Erance


Phone: 33 (0) 2 38 63 81 00 - Eax: 33 (0) 2 38 63 81 82
E-mail: irisinsattglobal.net
Web site: www.iris-instruments.com
llRRll8 8 llNN8 811RR00MMEENN1 188
SYSCAL Kid
RESISTIVITY METER
FOR ARCHAEOLOGY
AND ENGINEERING
N Automatic ranging
N Direct resistivity reading
N Built in data logger
N Field proof
IRIS Instruments is pleased to introduce its new resistivity meter, SYSCAL Kid, a very compact unit
specially designed Ior shallow electrical surveys. The SYSCAL Kid oIIers the well-known reliability
and measurement accuracy oI the entire SYSCAL range oI resistivity meters.
Easy-to-use, Iield prooI and light weight, SYSCAL Kid is ideal Ior archaeological, geological mapping
and civil engineering applications.
APPLICATIONS MA1OR BENEFITS
N Shallow ground resistivity
N Archaeology surveys
N Civil engineering
N Geological mapping
N Attractive output parameters:
- 200 V maximum voltage,
- 25 W maximum power,
- 500 mA maximum current
N Automatic Iixing oI the
output voltage in relation with
the level oI the measured
signal.
N Internal memory Ior more
than 1400 Iull stations.
N Accuracy on resistivity: 1.
N Quality control oI the
measurement through standard
deviation and number oI stacks.
N Display oI measured voltage,
intensity oI current, apparent
resistivity, and selI potential.
N Serial link Ior transIer to PC.
IRIS Instruments - 1 avenue BuIIon, B.P. 6007, 45060 Orleans Cedex 2, Erance
Phone: 33 (0) 2 38 63 81 00 - Eax: 33 (0) 2 38 63 81 82 - E-mail: irisinsattglobal.net
Web site: www.iris-instruments.com
SYSCAL Kid
GENERAL SPECIFICATIONS
E LCD display: 4 lines oI 20 characters
E Keypad: 6 Iunctions keys
E Operating temperature range: -10 to 50 C
E Internal rechargeable battery: 12 V, 6.5 Ah
E Autonomy: 3000 readings typical.
E Internal memory oI 1400 stations with Iull readings:
selI-potential, voltage, current, resistivity
E Dimensions: 23 x 18 x 17 cm
E Weight: 4.1 kg
TRANSMITTER
E Automatic current setting
E Output voltage: up to 200 V
E Output current: up to 500 mA
E Output power: up to 25 W
E Optional external 12V battery input
E Cycle time: 1 or 2 s
RECEIVER
E Resistivity computation
E Automatic ranging
E SP compensation including linear driIt
E Digital stacking Ior noise reduction
E Input voltage: protection up to 200 V
range Irom - 2.5 V to 2.5 V
E Input impedance: 22 M
E Resistivity range: 10
-3
to 10
5
.m
E Resistivity precision: 1 typical
RESISTIVITY MEASUREMENTS
2 1
2 1
C C
P P
a 2

'
,
5 7
Available arrays:
N Schlumberger
N Wenner
N Gradient
N Dipole-Dipole
N Pole-Dipole
N Pole-Pole
N Other (user deIined)
a a a

C
1
P
2
C
2
P
1
Ground resistivity (Wenner)